WorldWideScience

Sample records for transplantation mr-tomographie von

  1. MR imaging of articular cartilage; Gelenkknorpel in der MR-Tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, F.K.W.; Muhle, C.; Heller, M.; Brossmann, J. [Kiel Univ. (Germany). Klinik fuer Diagnostische Radiologie

    2001-04-01

    MR imaging has evolved to the best non-invasive method for the evaluation of articular cartilage. MR imaging helps to understand the structure and physiology of cartilage, and to diagnose cartilage lesions. Numerous studies have shown high accuracy and reliability concerning detection of cartilage lesions and early changes in both structure and biochemistry. High contrast-to-noise ratio and high spatial resolution are essential for analysis of articular cartilage. Fat-suppressed 3D-T{sub 1} weighted gradient echo and T{sub 2}-weighted fast spin echo sequences with or without fat suppression are recommended for clinical routine. In this article the anatomy and pathology of hyaline articular cartilage and the complex imaging characteristics of hyaline cartilage will be discussed. (orig.) [German] Die MR-Tomographie hat sich zur besten nichtinvasiven bildgebenden Methode fuer die Untersuchung von Gelenkknorpel entwickelt. Die MR-Tomographie liefert einen Beitrag zum Verstaendnis der Knorpelstruktur und der Physiologie sowie zur Diagnostik von Knorpelschaeden. Zahlreiche MR-Studien konnten eine hohe Genauigkeit und Zuverlaessigkeit bei der Detektion chondraler Laesionen sowie frueher Veraenderungen struktureller und biochemischer Natur zeigen. Neben einem hohen Kontrast/Rausch-Verhaeltnis ist fuer die Gelenkknorpelanalyse eine hohe raeumliche Aufloesung erforderlich. Im klinischen Routinebetrieb empfehlen sich fuer die Erkennung von Knorpellaesionen besonders fettunterdrueckte 3D-T{sub 1}-gewichtete Gradientenecho- und T{sub 2}-gewichtete Fastspinecho-Sequenzen mit oder ohne Fettunterdrueckung. Die vorliegende Arbeit geht auf die Anatomie und Pathologie des hyalinen Gelenkknorpels ein und diskutiert das komplexe MR-Signalverhalten. (orig.)

  2. Von Mr Classic zu Mr Nerd: Wie Forschende soziale Medien nutzen

    Directory of Open Access Journals (Sweden)

    Doreen Siegfried

    2014-12-01

    Full Text Available Unter Wissenschaftlerinnen und Wissenschaftlern lassen sich vier Typen differenzieren, die ein signifikant unterschiedliches Verhalten in ihrer Nutzung und ihrer Einstellung gegenüber Social-Web-Anwendungen zeigen: Ms Maker, Mr Tech, Mr Classic und Mr Nerd. Grundlage für die Identifizierung dieser Social-Media-Typen ist die Auswertung von 778 Online-Fragebögen, die von Anfang September bis Mitte Oktober 2013 erhoben wurden. Erfragt wurde die Nutzung von Social-Media-Instrumenten für die tägliche Arbeit in Forschung, Lehre, Administration und Wissenschaftskommunikation. Neben Intensität und Kontext der Nutzung von Web-2.0-Diensten wurden auch die Gründe für Nutzung bzw. Nicht-Nutzung einzelner Kanäle sowie generelle Einstellungen gegenüber Social-Media-Werkzeugen erfragt. Among scientists, four types of personality can be identified whose usage and attitude towards social web applications show significant variations: Ms Maker, Mr Tech, Mr Classic and Mr Nerd. This typification is based on 778 online questionnaires received between September and October 2013. The survey sampled the usage of social media tools for daily routines in research, teaching, administrative work and scholarly communication. The survey asked questions about the intensity and the context in which Web 2.0 services are used, about the reasons for (not using certain channels, and about general attitudes towards social media tools.

  3. Indirect MR-arthography in the fellow up of autologous osteochondral transplantation; Indirekte MR-Arthrographie zur Verlaufskontrolle nach autologer osteochondraler Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Herber, S.; Pitton, M.B.; Kalden, P.; Thelen, M.; Kreitner, K.F. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Unfallchirurgie

    2003-02-01

    following autologous osteochondral transplantation. Assessment of transplant vitality, osseous fixation and stability is possible. (orig.) [German] Zielsetzung: Evaluation der Befunde nach indirekter MR-Arthrographie bei Patienten mit autologer osteochondraler Transplantation. Patienten und Methoden: 10 konsekutive Patienten mit einer Mosaik-Plastik wurden drei, 6 und 12 Monate nach dem Eingriff mittels indirekter MR-Arthrographie untersucht. Das MR-Protokoll bei 1,5T beinhaltete neben nativen PD- und T{sub 2}-gewichteten TSE-Sequenzen mit und ohne Fett-Suppression T{sub 1}-gewichtete, fettsupprimierte SE-Sequenzen vor und unmittelbar nach Kontrastmittelgabe sowie nach Bewegung des Gelenkes. Die Bildanalyse wurde gemeinsam von zwei Radiologen durchgefuehrt und beinhaltete die Auswertung der Signalintensitaet (SI) und Integritaet des knoechernen Zylinders ebenso wie der Knorpeloberflaeche, das Vorhandensein eines Knochenmarkoedems und eines Gelenkergusses. Ergebnisse: Drei Monate nach dem Eingriff zeigte sich in allen Faellen in der T{sub 2}-TSE-Sequenz ein ausgepraegtes Knochenmarkoedem auf Empfaenger- und Donorseite, korrespondierend zu einem deutlichem Signalintensitaetsanstieg nach Kontrastmittelgabe. Die Grenzzone zwischen dem Transplantat und dem originaerem Knochen zeigte eine erhoehte SI nach drei und 6 Monaten in der T{sub 2}-TSE-Sequenz sowie nach i.v. Gd-DTPA-Gabe. Eine Transplantatdislokation wurde in keinem Fall beobachtet. Als Zeichen der Vitalitaet des osteochondralen Transplantats normalisierte sich das Marksignal in der T{sub 1}-SE-Sequenz in den meisten Faellen nach 6 bzw. 12 Monaten. Die indirekte MR-Arthrographie war dem Nativ-Scan ueberlegen bei der Beurteilung der knorpeligen Ueberdeckung des Transplantats. In allen Faellen zeigte sich eine komplette Ueberdeckung des knoechernen Zylinders mit Gelenkknorpel. Transplantierter und originaerer hyaliner Knorpel zeigten einen deutlichen Anstieg der SI in der indirekten MR-Arthrographie. Signalalterationen und

  4. MR imaging of prostate cancer; MR-Tomographie des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, A.; Scheidler, J.; Sommer, B.; Graser, A. [Radiologisches Zentrum Muenchen-Pasing (Germany); Mueller-Lisse, U.G. [Institut fuer Klinische Radiologie, Universitaet Muenchen (Germany); Massmann, J. [Gemeinschaftspraxis Pathologie, Muenchen (Germany)

    2003-06-01

    Abklaerung. Die MRT ist dabei dem TRUS sowohl in der Tumordetektion und Lokalisation als auch beim Staging ueberlegen. Die Untersuchungstechnik fuer hochaufloesende MR-Untersuchungen der Prostata beinhaltet die Verwendung einer Kombination von Endorektal- und Phased-array-Spulen sowie den Einsatz multiplanarer T2w-FSE- und T1w-SE-Sequenzen. Die in der Literatur mitgeteilten neueren Ergebnisse fuer die Treffsicherheit im Staging des PC liegen bei 82-88% mit Sensitivitaeten von 80-95% und Spezifitaeten von 82-93%. Eigene Ergebnisse fuer das Tumorstaging ergaben bei 106 radikal operierten Patienten fuer die Beurteilung eines kapselueberschreitenden Wachstums eine Sensitivitaet von 91 und eine Spezifitaet von 83%; die entsprechenden Ergebnisse fuer die Erkennung einer Samenblaseninfiltration waren 86 und 93%. Es werden die typischen, stadienbezogenen Befunde des Prostatakarzinoms in der MRT als auch die wichtigsten differenzialdiagnostischen Probleme wie chronische Prostatitis, biopsiebedingte Einblutungen und therapiebedingte Strukturveraenderungen der Prostata besprochen. Auch die aktuellen diagnostischen Moeglichkeiten und Grenzen der MR-Spektroskopie der Prostata werden diskutiert. (orig.)

  5. MR imaging of von Hippel-Lindau disease

    International Nuclear Information System (INIS)

    Sato, Y.; Waziri, M.H.; Smith, W.L.; Frey, E.E.; Franken, E.A.

    1986-01-01

    Sixteen patients with von Hippel-Lindau disease (VH-L) and 11 asymptomatic family members underwent a total of 29 central nervous system (CNS) and 23 body MR imaging evaluations during a 2-year study period. Nineteen CNS and spinal lesions and nine abdominal visceral lesions were identified on MR imaging and were confirmed at surgery or by other imaging modalities. MR imaging is superior to CT in the evaluation of intraocular vitreous abnormalities and cerebellar and spinal hemangioblastomas because of superior tissue characterization and lack of bone artifacts. MR imaging adequately demonstrated the abdominal visceral lesions. MR imaging is a sensitive and reliable imaging modality for the various lesions of VH-L

  6. MR Imaging of renal transplants

    International Nuclear Information System (INIS)

    Gremo, L.; Avataneo, T.; Potenzoni, F.; Colla, L.; Segoloni, G.

    1988-01-01

    The authors report their experience in the study of renal transplant recipients by MR, in order to determine its clinical potentials. The main purpose of this work is to focus on MR patterns in relation to clinical findings of rejector or normally fuctioning kidney. Twenty-four patients were examined with a 0.5 T superconductive magnete, body coil, spin-echo pulse sequence (SE) and inversion-recovery (IR). MRI patterns could be seen in normally functioning kidneys and transplant rejections, while variable MRI findings were observed in transplants with acute tubular necrosis (ATN). In the normally functioning transplanted kidney there is a clear corticomedullary differentiation (CMD), and the extent of vascular penetration into the renal parenchyma is clearly seen. In transplant rejection, CMD is either diminished or absent, and there is no vascular penetration into the parenchyma; to differentiate acute from chronic rejections, the increase/decrease in renal size and the change in renal shape (spherical shape in acute transplant rejection) respectively must be observed. MRI proves thus to be useful in the study of renal transplants, even in case of questionable clinical findings, and in patients in whom renal biopsy is contraindicated

  7. MR tomography of the elbow joint

    Energy Technology Data Exchange (ETDEWEB)

    Zwaan, M.; Rinast, E.; Weiss, H.D.; Pressler, M.; Vogel, H.

    1989-03-01

    MR examinations of the elbow joint of three healthy subjects and a comparison with corresponding sections of anatomical preparations show that MR tomography enables not only an excellent differentiation of muscles, tendons and of the articular capsule, but will also visualise vessels and nerve tracts. MR tomography proved superior to the conventional methods in demonstration of separate fragments and inflammatory changes in the bone on examining 11 pathological elbow joints: congenital malformation, osteochondritis dissecans, ostitis, ulnar and radial nerve lesions, completely healed radius fracture and epicondylitis of the radial and ulnar humerus. Epicondylitis could not be demonstrated by MR. Magnetic resonance tomography seems to be the only method that enables direct visualisation of the nerve paths at the elbow joint.

  8. Value of new MR techniques in MR-PET; Stellenwert neuer MR-Techniken in der MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Quick, H.H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany); Guimaraes, A. [Massachusetts General Hospital, Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown (United States); Catalano, O. [University of Naples Federico II, Naples (Italy); Morelli, J.N. [The Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore (United States)

    2013-12-15

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [German] Die klinische Implementierung der neuen Hybridtechnologie MR-Positronenemissionstomographie (MR-PET) bietet durch die Kombination aus hochaufloesender Morphologie, Funktion und Metabolismus bisher ungeahnte diagnostische Moeglichkeiten, die nicht nur fuer die Diagnose und die Verlaufskontrolle onkologischer und psychiatrischer Erkrankungen von hoher Bedeutung sind. Verglichen mit der PET-CT wird dies mit reduzierter Strahlenbelastung fuer den Patienten moeglich, was wiederum insbesondere fuer Patienten in der Tumornachsorge, die

  9. 31P MR spectroscopic imaging in preoperative embolization therapy of meningiomas; Phosphor-31-MR-spektroskopische Bildgebung bei praeoperativer Embolisationstherapie von Meningeomen

    Energy Technology Data Exchange (ETDEWEB)

    Blankenhorn, M. [Psychiatrische Universitaetsklinik, Ulm (Germany). Abteilung III; Bachert, P.; Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik; Semmler, W. [Freie Univ. Berlin (Germany). Inst. fuer Diagnostikforschung; Ende, G. [Zentralinstitut fuer Seelische Gesundheit, Mannheim (Germany). NMR-Forschung in der Psychiatrie; Tronnier, V. [Neurochirurgische Klinik, Klinikum der Universitaet, Heidelberg (Germany); Sartor, K. [Neurologische Klinik, Klinikum der Universitaet, Heidelberg (Germany). Abt. Neuroradiologie

    1999-06-01

    Purpose: {sup 31}P MR spectroscopic imaging ({sup 31}P SI) was evaluated in a clinical study as a method for monitoring presurgical devascularization of meningiomas. The aim was to assess noninvasively metabolic alterations in tumor and in healthy brain tissue before and after embolization. Methods: Localized {sup 31}P MR spectra of the brain were obtained by means of 2D-SI (voxel size: 36 cm{sup 3}) using a 1,5-T whole-body MR tomograph. Results: Eleven of 19 patients with intracranial meningiomas examined in this study underwent preoperative embolization therapy; eight patients were examined before and after treatment. After embolization, alterations of pH and of the concentrations of high-energy phosphates (nucleoside-5`triphosphate=NTP, phosphocreatine=PCr), inorganic phosphate (P{sub i}), and membrane constituents were observed in the tumors. A tendency of [P{sub i}] increase and decrease of [NTP], [PCr], and pH predominated, which is explained by ischemic processes after tumor devascularization. Conclusion: {sup 31}P SI is applicable in clinical studies and detects alterations of phosphate metabolism in a meningioma after embolization. (orig.) [Deutsch] Ziel: Die {sup 31}P-MR-spektroskopische Bildgebung ({sup 31}P-SI) wurde im Rahmen der praeoperativen Embolisationstherapie von Patienten mit Meningeomen als Methode zur Therapieverlaufskontrolle klinisch geprueft. Ziel der Studie war die nichtinvasive Erfassung von Veraenderungen im Metabolismus der Tumoren vor und nach Embolisation im Vergleich zum gesunden Hirngewebe. Methoden: Lokalisierte {sup 31}P-MR-Spektren des Gehirns wurden mit 2D-SI (Voxelgroesse: 36 cm{sup 3}) an einem 1,5-T-Ganzkoerper-MR-Tomographen aufgenommen. Ergebnisse: Elf von insgesamt 19 untersuchten Patienten unterzogen sich einer praeoperativen Embolisation, bei acht Patienten konnte eine Verlaufskontrolle durchgefuehrt werden. Nach Embolisation wurden Veraenderungen des pH und der Konzentrationen von energiereichen Phosphaten (Nukleosid

  10. Indirect MR arthrography in the evaluation of tears of the glenoid labrum; Indirekte MR-Arthrographie in der Diagnostik von Laesionen des Labrum glenoidale

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Vahlensieck, M.; Lutterbey, G.; Pauleit, D.; Kreft, B.; Keller, E.; Schild, H. [Radiologische Universitaetsklinik Bonn (Germany); Wallny, T. [Orthopaedische Universitaetsklinik Bonn (Germany); Steuer, K.; Golombek, V. [Klinik fuer Unfallchirurgie, Univ. Bonn (Germany)

    1997-07-01

    Purpose: It has been shown that intravenous administration of contrast media produces an MR arthrographic effect without the need for intraarticular injection. This is the first study evaluating this new technique of indirect MR arthrography in the diagnosis of glenoid labrum tears. Methods: 28 patients with clinically suspected labral injuries were prospectively investigated (1.5 Tesla, flexible surface coil). A plain MR examination of the shoulder (transverse and oblique-coronal orientation, T{sub 1}-weighted spin- [T{sub E}/T{sub R} 15/675], proton density- and T{sub 2}*-weighted gradient echo [T{sub E}/T{sub R}/Flip 14,32/600/30 ] sequences) and indirect MR arthrography (transverse and oblique-coronal orientation, fat-suppressed T{sub 1}-weighted spin-echo sequences [T{sub E}/T{sub R} 15/675], intravenous injection of gadopentetate dimeglumine [0.1 mmol/kg], followed by 10-15 min of joint movement) were performed. Results were confirmed by arthroscopy and/or open surgery. Results: Indirect MR arthrography significantly improved delineation of the glenoid labrum and hyaline cartilage (p<0.05). Sensitivity and specificity of indirect MR arthrography in the diagnosis of labral injuries were 90% and 89%, compared to 79% and 67% of the native MR examination. Conclusion: Indirect MR arthrography is a promising non-invasive technique in the evaluation of the glenoid labrum. (orig.) [Deutsch] Ziel: In frueheren Studien wurde gezeigt, dass die intravenoese Injektion gadoliniumhaltiger Kontrastmittel zur Signalintensitaetssteigerung im Gelenkkavum fuehrt. In dieser Studie wurde erstmals diese Technik der indirekten MR-Arthrographie am Schultergelenk in der Diagnostik von Labrumlaesionen evaluiert. Methode: 28 Patienten mit klinischem Verdacht auf eine Verletzung des Labrum glenoidale und/oder der Rotatorenmanschette wurden prospektiv nach folgendem Protokoll an einem 1,5-Tesla-System mit einer Oberflaechen-Ringspule untersucht: 1. Native MR-Standard-Untersuchung mit

  11. LOCUS MR: Localization of unaffected spins in MR tomography and MR spectroscopy

    International Nuclear Information System (INIS)

    Matthael, D.; Haase, A.

    1986-01-01

    Different pulse sequences have been proposed for localized in vivo MR spectroscopy. For localized MR tomography and MR spectroscopy, a method is proposed, dubbed LOCUS (LOCalization of Unaffected Spins) MR. The method uses the initial saturation of regions surrounding the region of interest (ROI) in the presence of gradients. This is followed by a conventional MR study of the unaffected ROI. In animals, human extremities, and phantoms, proton MR studies demonstrated that the method provides an optimal signal-to-noise ratio, an easily variable ROI, and ROI shim. The method can be combined with two- and three-dimensional imaging, and it allows localized measurement of MR parameters. The multinuclear capability is discussed

  12. Iron overload following bone marrow transplantation in children: MR findings

    International Nuclear Information System (INIS)

    Kornreich, L.; Horev, G.; Grunebaum, M.; Yaniv, I.; Stein, J.; Zaizov, R.

    1997-01-01

    Objective. The purpose of this study was to determine the incidence of post-transfusional iron overload in children after bone marrow transplantation by reviewing their magnetic resonance imaging (MR) findings. Materials and methods. We reviewed the abdominal MR studies of 13 children after autologous bone marrow transplantation. Nine of the children had also undergone MR prior to transplantation. Iron deposition in the liver, spleen and bone marrow was graded semi-quantitatively on both T1- and T2-weighted images. Serum ferritin levels and number of blood units given after bone marrow transplantation were recorded. Results. None of the pre-transplantation MR studies revealed iron overload. After bone marrow transplantation, three children showed normal liver and spleen. Iron overload in the liver was noted in ten patients (77 %), six of whom also showed iron overload in the spleen (46 %) and five in the bone marrow (38.5 %). The degree of hepatic iron overload was correlated significantly and splenic iron overload was correlated weakly with the number of blood transfusions (P 0.01 and P > 0.01, respectively), but neither was correlated with the serum ferritin level. Conclusion. Iron overload commonly accompanies bone marrow transplantation. The observed pattern of iron deposition, in which the spleen was uninvolved in 40 % of patients demonstrating iron overload, is not typical of post-transfusional hemochromatosis. (orig.)

  13. Evaluation of living liver transplant donors: method for precise anatomic definition by using a dedicated contrast-enhanced MR imaging protocol.

    Science.gov (United States)

    Sahani, Dushyant; D'souza, Roy; Kadavigere, Rajagopal; Hertl, Martin; McGowan, Jennifer; Saini, Sanjay; Mueller, Peter R

    2004-01-01

    Liver transplantation from a living donor involves removal of part of the donor liver in a fashion that does not endanger its vascular supply or metabolic function. The radiologist plays an important role in evaluation of the living donor to define the conditions under which graft donation is contraindicated and to identify anatomic variations that may alter the surgical approach. In the past, diagnostic work-up of the donor involved costly and invasive tests. Currently, dynamic contrast material-enhanced computed tomography and magnetic resonance (MR) imaging are the imaging tests performed, each of which has advantages and limitations. MR imaging performed with liver-specific and extravascular contrast agents may be used as a single imaging test for comprehensive noninvasive evaluation of living liver transplant donors. MR imaging provides valuable information about variations in the vascular and biliary anatomy and allows evaluation of the hepatic parenchyma for diffuse or focal abnormalities. Copyright RSNA, 2004

  14. MR-evaluation of left myocardial function in transplanted hearts

    International Nuclear Information System (INIS)

    Rienmuller, R.K.; Lioret, J.; Kemkes, B.; Erdmann, E.; Gartner, C.; Hacker, H.; Tilling, R.

    1988-01-01

    Of 60 heart transplant recipients, 25 were restudied with magnetic resonance (MR) imaging after 1 year to evaluate the left ventricular myocardial (LVM) function, Seven healthy subjects and 15 patients with dilated cardiomyopathy (DCM) served as controls. EDV, ejection fraction (EF), LVMM, wall stress (T-diastolic, T-systolic), and LVM contraction and relaxation (LVMC, LVMR) were measured over a cardiac cycle and compared with angiocardiographic and clinical data. The results showed that EDV and EF were normal in heart transplant recipients both initially and at follow-up, and in healthy subjects. LVMM was significantly increased in patients with DCM and less so in transplant recipients. T-diastolic wall stress was increased in transplant recipients and patients with DCM. The isovolumetric part of LVMC and the LVMR were reduced in these groups, corresponding to restrictive hemodynamics. In transplant recipients at follow-up, a progressive reduction in LVMR was found. In transplant recipients with global myocardial ischemia, LVMM,LVMC,LVMR, and EF are continuously decreasing, in contrast to acute or subacute rejection, where LVMM was found unchanged or increased. In conclusion, LVMM, LVMR, and LVMC as determined by MR imaging are sensitive quantitative indexes of various causes of altered LVM function that result from (sub) acute, chronic rejection or graft atherosclerosis

  15. MR imaging and CT findings after liver transplantation

    International Nuclear Information System (INIS)

    Langer, M.; Langer, R.; Scholz, A.; Zwicker, C.; Astinet, F.

    1990-01-01

    The aim of the paper is to evaluate MR imaging and dynamic CT as noninvasive procedures to image signs of graft failure after an orthotopic liver transplantation (OLT). Thirty MR studies and 50 dynamic CT examinations were performed within 20 days after OLT. MR examinations were performed with a 0.5-T Siemens Magnetom. CT scans were obtained by using a Siemens Somatom Plus. In all patients, MR images demonstrated a perivascular rim of intermediate signal intensity on T1-weighted and increased signal intensity on T2-weighted images in the hilum of the liver; in 20/26, this was seen in peripheral areas also. In all patients, a perivascular area of low attenuation was diagnosed at angio-CT

  16. Influence of age and menstrual cycle on mammography and MR imaging of the breast; Einfluss von Alter und Menstruationszyklus auf Mammographie und MR-Mammographie

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Schimpfle, M.; Ohmenhaeuser, K.; Claussen, C.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik

    1997-09-01

    Age and menstrual cycle have an important influence on the breast. This well-known fact is experienced in the daily routine of gynecologists and radiologists. The number of publications addressing the effect of these influences on imaging, however, is surprisingly low. The aim of this work is to describe the influences of age and menstrual cycle on the breast and to address their clinical relevance for mammography and MR mammography. Therefore, own data are presented concerning the age and menstrual cycle influences on breast parenchyma in dynamic MR mammography. Literature data are used to correlate mammography and MR imaging findings with these influences. The changes of the breast due to age and menstrual cycle have important direct implications on performing and reading conventional mammography and MR mammography. The knowledge of these changes is also helpful in the interpretation of findings when comparing different methods. Finally, the data gained by using imaging methods enable important basic insights into physiology and physiopathology of the breast in vivo. (orig.) [Deutsch] Alter und Menstruationszyklus stellen wichtige Einflussfaktoren auf die Mamma dar. Diese Tatsache ist klinisch lange bekannt und im Alltag des Gynaekologen wie Radiologen staendig praesent. Dagegen ist die Anzahl der Publikationen zu den Auswirkungen dieser Einfluesse auf die Bildgebung erstaunlich niedrig. Ziel dieser Arbeit ist es, die alters- und zyklusabhaengigen Veraenderungen der Mamma und deren klinische Relevanz fuer die Mammographie und MR-Mammographie darzustellen. Zu diesem Zweck werden aus einer eigenen Studie Daten der dynamischen MR-Tomographie zum Alters- und Zykluseinfluss auf das Mammaparenchym praesentiert. Darueber hinaus werden diese Einflussfaktoren mit mammographischen und MR-tomographischen Daten aus der Literatur korreliert. Dabei zeigt sich, dass sich aus den alters- und menstruationszyklusbedingten Veraenderungen der Brust wichtige unmittelbare

  17. MR tomography in Kallmann's syndrome

    International Nuclear Information System (INIS)

    Dewes, W.; Krahe, T.; Klingmueller, D.; Harder, T.; Bonn Univ.

    1987-01-01

    MR tomography is the only imaging method that can demonstrate atrophy of the olfactory lobe of the brain in olfacto-genital dysplasia (Kallmann's syndrome). The MRT findings in five patients with Kallmann's syndrome are described. The MRT criterion for the presence of Kallmann's syndrome appears to be an interruption or total absence of the olfactory sulcus. (orig.) [de

  18. Computed tomography of von Meyenburg complex simulating micro-abscesses

    International Nuclear Information System (INIS)

    Sada, P.N.; Ramakrishna, B.

    1994-01-01

    A case is presented of a bile duct hamartoma in a 44 year old man being evaluated for abdominal pain. The computed tomography (CT) findings suggested micro-abscesses in the liver and a CT guided tru-cut biopsy showed von Meyenburg complex. 9 refs., 3 figs

  19. Evaluation of renal transplants with Gd-DOTA dynamic MR imaging with factor analysis

    International Nuclear Information System (INIS)

    Chabrials, J.; Frouin, F.; Helenon, O.; Benall, H.; Kreis, H.; Moreau, J.F.; Di Paola, R.

    1990-01-01

    This paper reports on renal and urinary excretion factors by means of Gd-DOTA dynamic MR imaging and using factor analysis of dynamic structure (FADS) to follow-up renal transplants. We examined 60 patients with renal transplants by use of dynamic MR imaging after administration of a Gd-DOTA bolus (0.2 ml/kg) on a 0.5-T system; 10--12 fast gradient-echo sequences (TR/TE = 40/14, flip angle = 45 degree, acquisition time = 13 seconds) with single images and a 32-second intersequence delay were used. Of these, 13 dynamic MR imaging sequences were processed with an extension to dynamic MR images of FADS, previously developed to analyze nuclear medicine dynamic studies. The results were compared with the results of biologic dosages, renal biopsy and Seldinger digital arteriography

  20. MR renography by semiautomated image analysis : Performance in renal transplant recipients

    NARCIS (Netherlands)

    de Priester, JA; Kessels, AGH; Giele, ELW; den Boer, J.A.; Christiaans, MHL; Hasman, A; van Engelshoven, JMA

    We evaluated a method of semiautomated analysis of dynamic MR image series in renal transplants. Nine patients were studied twice, with an average time interval of 7 days. MR examination consisted of a run of 256 T1-weighted coronal scans (GE; TR/TE/flip: = 11/3.4/60 degrees; slice thickness = 6 mm;

  1. MR imaging of renal transplant rejection

    International Nuclear Information System (INIS)

    Hanna, S.; Helenon, O.; Legendre, C.; Chichie, J.F.; Di Stefano, D.; Kreis, H.; Moreau, J.F.; Hopital Necker, 75 - Paris

    1991-01-01

    The results of 62 consecutive MR examinations were correlated with the subsequent clinical course and histologic results. Twenty-six cases of rejection showed a marked diminution of cortico-medullary differentiation (CMD). The renal parenchymal vascular pattern and visibility of renal sinus fat were not markedly altered in rejection and there was no difference between normal and rejected allograft shape. The ability of MR imaging to diagnose renal transplant rejection is only based on CMD, which, however, is non-specific. In 2 cases of severe rejection, T2 weighted images showed an abnormal signal intensity of the cortex due to renal infarction. Our preliminary results in 8 patients with Gd-DOTA injection showed 2 cases with necrosis seen as areas with absent contrast enhancement. This technique seems to be promising in the detection of perfusion defects. (orig.)

  2. Biliary complications following orthotopic liver transplantation: May contrast-enhanced MR Cholangiography provide additional information?

    Directory of Open Access Journals (Sweden)

    Piero Boraschi

    2016-01-01

    Conclusions: Contrast-enhanced T1-weighted MR Cholangiography may improve the level of diagnostic confidence provided by conventional T2-weighted MR Cholangiography in the evaluation of biliary complications after orthotopic liver transplantation.

  3. MR Measurement Technique of Rapidly Switched Gradient Magnetic Fields in MR Tomography

    Czech Academy of Sciences Publication Activity Database

    Bartušek, Karel; Gescheidtová, E.

    2005-01-01

    Roč. 29, č. 4 (2005), s. 675-686 ISSN 0937-9347 Institutional research plan: CEZ:AV0Z20650511 Keywords : MR tomography * gradiernt magnet ic field * IF method * IFSE method * IFSES method * spin echo Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.743, year: 2005

  4. MR imaging in gynecology and obstetrics; MR-Tomographie in Gynaekologie und Geburtshilfe

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, M.; Tontsch, P.; Schulz-Wendtland, R. (eds.)

    2000-07-01

    The toolbook covers the full range of indications for MRI in obstetrics and gynecology. It is the joint work of radiologists and obstetrician-gynecologists and supplies state-of-the-art information needed by doctors in the private practice or a hospital department. Examples from the Table of Contents: Physical principles of MRI, applications and performance aspects. Systematic presentation of diagnostic findings for comparative analysis and assessment. Biological effects and risks. Benign and malignant neoplasms of the mammary glands and the female genital organs. MRI for prenatal care and diagnostic evaluation. New method: MR spectroscopy. (orig./CB) [German] Das Lehrbuch deckt alle Indikationen der MRT in Gynaekologie und Geburtshilfe ab. Es wurde von Radiologen und Frauenaerzten gemeinsam verfasst und ist daher praxisgerecht. Aus dem Inhalt: Physikalische Grundlagen und Durchfuehrung der MRT und Systematik fuer die Beurteilung der MRT-Befunde. Biologische Wirkungen und Risiken, benigne und maligne Erkrankungen der Brustdruese und der weiblichen Genitalorgane. MRT in der Schwangerschaft. Neue Methode: MR-Spektroskopie. (orig./AJ)

  5. MR of the muskuloskeletal system: A review; MR-Tomographie (MRT) des Skeletts, der peripheren Weichteile und der Gelenke - aktuelle Uebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Bohndorf, K. [Zentralklinikum Augsburg (Germany). Klinik fuer Diagnostische und Neuroradiologie; Kretschmer, K.H. [Zentralklinikum Augsburg (Germany). Klinik fuer Diagnostische und Neuroradiologie

    1996-05-01

    The skeleton, the peripheral soft tissues, and the joints have become important indications to use MRI routinely. About 25-35% of daily examinations focus on these anatomic sites. Superior contrast resolution, the option of different imaging planes, and the unsurpassed visualization of bone marrow, fibrous and hyaline cartilage, ligaments, and tendons are the reasons for the overwhelming success of this imaging method. MRI often provides the direct way to diagnosis. More and more the so-called `step by step` approach to diagnosis by imaging methods is being abandoned in favor of the primary use of MRI. The present survey summarizes the main indications for MRI in the field of the musculoskeletal system, in adults as well as in children. Special topics like tumors, inflammation, ischemia, and trauma are discussed. Some anatomic sites like the carpal joint, the shoulder, and the knee are presented in more detail. (orig.) [Deutsch] Eine Vielzahl von Fragestellungen zu wesentlichen Indikationen der MR-Tomographie am Skelett, den peripheren Weichteilen und den Gelenken haben sich in der taeglichen Praxis entwickelt. Durchschnittlich 25-35% der taeglichen Untersuchungen betreffen diesen Themenkreis. Ueberlegene Kontrastaufloesung, die Darstellung in beliebig waehlbaren Ebenen und die unuebertroffene Visualisierung von Strukturen wie Knochenmark, fibroesem und hyalinem Knorpel, Ligamenten und Sehnen, sind die Ursache der raschen Verbreitung der Methode. Die MRT stellt haeufig den direkten Weg zur Diagnose dar und ersetzt zunehmend die sog. `Stufendiagnostik` und damit Methoden wie die Computertomographie, Arteriographie oder auch Skelettszintigraphie. In der vorliegenden Uebersicht werden wesentliche, heute als gesichert anzusehenden Anwendungsgebiete der MRT bei Kindern und Erwachsenen zusammengefasst. Die Arbeit gibt einen Ueberblick ueber spezielle Fragestellungen bei Tumoren, Entzuendungen, Ischaemie und traumatischen Fragestellungen. Eine Reihe von anatomischen

  6. MR appearances of bone marrow in children following bone marrow transplantation

    International Nuclear Information System (INIS)

    Boothroyd, A.E.; Sebag, G.; Brunelle, F.

    1991-01-01

    Two cases are presented of children who demonstrated complete absence of bone marrow signal on MR imaging of the spine following bone marrow transplantation. The possible causes for these appearances are discussed. (orig.)

  7. Macromolecular contrast media. A new approach for characterising breast tumors with MR-mammography; Makromolekulare Kontrastmittel fuer die MR-Mammographie. Ein neuer Ansatz fuer die Charakterisierung von Mammatumoren

    Energy Technology Data Exchange (ETDEWEB)

    Daldrup, H.E. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Roberts, T.P.L.; Roberts, H.C. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Muehler, A. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Berlex Laboratories, Wayne, NJ (United States); Gossmann, A. [Contrast Media Lab., Dept. of Radiology, California Univ., San Francisco, CA (United States)]|[Koeln Univ. (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Wendland, M.; Brasch, R.C. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Rosenau, W. [California Univ., San Francisco, CA (United States). Dept. of Pathology

    1997-09-01

    The value of macromolecular contrast agents (MMCM) for the characterization of benign and malignant breast tumors will be demonstrated in this review. Animal studies suggest a high potential of MMCM to increase the specificity of MR-mammography. The concept of tumor differentiation is based on the pathological hyperpermeability of microvessels in malignant tumors. MMCM show a leak into the interstitium of carcinomas, whereas they are confined to the intravascular space in benign tumors. Capabilities and limitations of the MMCM-prototype. Albumin-Gd-DTPA, for breast tumor characterization will be summarized and compared to the standard low molecular weight contrast agent Gd-DTPA. Initial experience with new MMCM, such as Dendrimers, Gd-DTPA-Polylysine and MS-325 will be outlined. The potential of `blood-pool`-iron oxides, such as AMI-227 for the evaluation of tumor microvascular permeabilities will be discussed. (orig.) [Deutsch] Diese Uebersicht stellt den Stellenwert makromolekularer Kontrastmittel (MMKM) fuer die MR-tomographische Charakterisierung von benignen und malignen Mammatumoren dar. Aufgrund experimenteller Studien lassen MMKM eine signifikante Verbesserung der Spezifitaet der dynamischen kontrastmittelunterstuetzten MR-Mammographie erwarten. Das differentialdiagnostische Konzept beruht auf der pathologischen Hyperpermeabilitaet von Kapillaren in Karzinomen, die einen MMKM-Austritt in das Tumorinterstitium bedingt, waehrend die intakten Kapillaren benigner Tumoren nicht permeabel fuer MMKM sind. Diagnostische Moeglichkeiten und Grenzen des MMKM-Prototyps, Albumin-Gd-DTPA (92 kD), werden dargestellt und mit dem niedermolekularen Standard-Kontrastmittel Gd-DTPA (500 D) verglichen. Erste Erfahrungen mit neuen, fuer die klinische Anwendung optimierten MMKM-Praeparaten, wie das Kaskadenpolymer, Gd-DTPA-Polylysine und das MS-325 werden vorgestellt. Das Potential von Blood-pool-Eisenoxidpraeparaten, z.B. AMI-227, fuer die Bestimmung von

  8. Functional MR urography in patients with renal transplants

    International Nuclear Information System (INIS)

    Knopp, M.V.; Doersam, J.; Oesingmann, N.; Piesche, S.; Hawighorst, H.; Wiesel, M.; Schad, L.R.; Kaick, G. van

    1997-01-01

    Purpose: To assess the value of functional magnetic resonance urography for the noninvasive postoperative evaluation of renal transplants. Methods: A saturation inversion projection sequence allows the selective imaging of strongly T1 weighted signal from the MR contrast agent. A coronal slab leads to images comparable to conventional urography which can be acquired as a sequence with four images per minute. Results: 15 patients with urologic questionable findings after renal transplantation were studied. FMRU revealed in 6 patients normal findings, in 6 moderate dilatation of the renal pelvis without any urodynamic relevant obstruction. 3 pathologic findings, ureteral leak, ureteropelvic-junction obstruction and ureteral stenosis were diagnosed and consequently surgically treated. The imaging quality in all studies was diagnostic and urologically relevant. Conclusion: FMRU can be used as a noninvasive technique for the assessment of renal transplant in cases with suspicion of complication in the excretory system. (orig.) [de

  9. Functional evaluation of transplanted kidneys by Gd-DTPA enhanced turbo FLASH MR imaging

    International Nuclear Information System (INIS)

    Nakashima, Rumi; Yamashita, Yasuyuki; Tomiguchi, Seiji; Tsuji, Akinori; Takahashi, Mutsumasa

    1996-01-01

    We evaluated the usefulness of dynamic turbo FLASH MR imaging in the differential diagnosis of complications after renal transplantation in 17 patients (10 from living relatives and 7 from cadavers). Coronal turbo FLASH dynamic images were obtained every 5 sec for 5 min after an intravenous bolus injection of Gd-DTPA. Corticomedullary differentiation (CMD) on spin echo coronal T 1 -weighted images and MR renogram patterns of the renal cortex and medulla were obtained for quantitative analysis of the Gd-DTPA-enhanced dynamic turbo-FLASH images. The signal intensity ratio of the medulla to cortex after Gd-DTPA enhancement was compared among four groups: normal (n=9), acute tubular necrosis (ATN) or cyclosporine A (CyA) tubulopathy (n=6), acute rejection (AR) in the living related donor kidney (n=4), and AR in the cadaveric kidney (n=5). Although loss of CMD was seen in severe renal dysfunction in the transplanted kidneys, there was considerable overlap among the four groups. On dynamic study, there was significant differences in the signal intensity ratio of the medulla to cortex between normally functioning kidneys or ATN/CyA tubulopathy and AR (p<0.01). In patients with severe renal dysfunction, the arterial cortical peak was indistinct. In conclusion, MR renograms obtained from dynamic turbo FLASH MR imaging played a significant role in evaluating dysfunction of the renal transplant. (author)

  10. Quantitative 1H MR spectroscopy of the brain in patients with congestive heart failure before and after cardiac transplantation

    International Nuclear Information System (INIS)

    Lim, Soo Mee; Lee, Ho Kyu; Choi, Choong Gon; Lim, Tae Hwan; Lee, Jung Hee

    1999-01-01

    To evaluate the effects of cardiac transplantation on the brain in patients with congestive heart failure (CHF), using quantitative 1 H MR spectroscopy ( 1 H-MRS). Ten patients with CHF underwent MRI and quantitative 1 H-MRS before and 1-2 and 4-9 months after cardiac transplantation. MR spectra were obtained from parietal white matter (PWM) and occipital gray matter (OGM) using PROBE (PROton Brain Exam). Changes in MR signal intensity were evaluated, and the cerebral metabolic concentrations in PWM and OGM were compared. For comparative purposes, 20 normal volunteers were included. No abnormal MR signal intensity was seen in the brain before or after cardiac transplantation. Changes in cerebral metabolic concentrations were observed on 1 H-MRS; concentrations of creatine (Cr) in PWM, and of N-acetylacepartate (NAA), Cr and myo-Inositol(mI) in OGM were significantly lower before transplantation. After successful transplantation, Cr levels returned to their normal range in PWM and OGM, while a slightly increase choline (Cho) level was observed in PWM. Cerebral hypoperfusion in CHF can be evaluated using 1 H-MRS. MRS may play a substantial role in monitoring the effect of cardiac transplantation

  11. Quantitative {sup 1}H MR spectroscopy of the brain in patients with congestive heart failure before and after cardiac transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Mee; Lee, Ho Kyu; Choi, Choong Gon; Lim, Tae Hwan [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of); Lee, Jung Hee [Asan Institute for Life Sciences, Seoul (Korea, Republic of)

    1999-12-01

    To evaluate the effects of cardiac transplantation on the brain in patients with congestive heart failure (CHF), using quantitative {sup 1}H MR spectroscopy ({sup 1}H-MRS). Ten patients with CHF underwent MRI and quantitative {sup 1}H-MRS before and 1-2 and 4-9 months after cardiac transplantation. MR spectra were obtained from parietal white matter (PWM) and occipital gray matter (OGM) using PROBE (PROton Brain Exam). Changes in MR signal intensity were evaluated, and the cerebral metabolic concentrations in PWM and OGM were compared. For comparative purposes, 20 normal volunteers were included. No abnormal MR signal intensity was seen in the brain before or after cardiac transplantation. Changes in cerebral metabolic concentrations were observed on {sup 1}H-MRS; concentrations of creatine (Cr) in PWM, and of N-acetylacepartate (NAA), Cr and myo-Inositol(mI) in OGM were significantly lower before transplantation. After successful transplantation, Cr levels returned to their normal range in PWM and OGM, while a slightly increase choline (Cho) level was observed in PWM. Cerebral hypoperfusion in CHF can be evaluated using {sup 1}H-MRS. MRS may play a substantial role in monitoring the effect of cardiac transplantation.

  12. MR tomography in the assessment of functional stability of posterolateral lumbar fusions

    International Nuclear Information System (INIS)

    Lang, P.; Genant, H.K.; Chafetz, N.; Steiger, P.; Stoller, D.; California Univ., San Francisco

    1987-01-01

    MR tomography was used to assess functional lumbar stability in 30 patients with posterolateral fusions. The vertebral bodies of 9 of the 12 patients with unstable lumbar fusions presented with areas of decreased signal intensity on T 1 - and intermediately weighted images, which increased on T 2 -weighting. The vertebrae of 15 of the 18 patients with stable fusions demonstrated zones of increased signal intensity on T 1 - and intermediately weighted images, which were less intense or invisible on T 2 -weighting. Surgical correlation was available in 11 of the 30 patients studied. Hyperemia and inflammation appear to be responsible for the abnormal signal intensities in the patients with stable fusions, whereas an increase in adipose marrow due to decreased biomechanical stress is thought to account for the atypical signal intensities in the vertebral bodies of the patients with stable fusions. MR tomography seems to be a potential method for evaluating functional lumbar fusion stability. MR tomography may be particularly helpful in those patients with multiple back surgeries and possible instability, recurrent disc herniation, or post-operative fibrosis. MR is recommended in the patient, who appears clinically unstable, whose radiographs and CT, however, do not demonstrate fusion failure. (orig.) [de

  13. [Comparative assessment of MR-semiotics of acutest intracerebral hematomas in low- and extra high-field frequency magnetic resonance tomography].

    Science.gov (United States)

    Skvortsova, V I; Burenchev, D V; Tvorogova, T V; Guseva, O I; Prokhorov, A V; Smirnov, A M; Kupriianov, D A; Pirogov, Iu A

    2009-01-01

    An objective of the study was to compare sensitivity of low- and extra high-field frequency magnetic resonance (MR) tomography of acutest intracerebral hematomas (ICH) and to assess differences between symptoms in obtained images. A study was conducted using experimental ICH in rats (n=6). Hematomas were formed by two injections of autologic blood into the brain. MR-devices "Bio Spec 70/30" with magnetic field strength of 7 T and "Ellipse-150" with magnetic field strength of 0,15 T were used in the study. MR-tomography was carried out 3-5 h after the injections. Both MR-devices revealed the presence of pathological lesion in all animals. Extra highfield frequency MR-tomography showed the specific signs of ICH caused by the paramagnetic effect of deoxyhemoglobin in T2 and T2*-weighted images (WI) and low frequency MR-tomography - in T2*-WI only. The comparable sensitivity of low- and extra high-field frequency MR-devices in acutest ICH was established.

  14. Iron Administration before Stem Cell Harvest Enables MR Imaging Tracking after Transplantation

    OpenAIRE

    Khurana, Aman; Chapelin, Fanny; Beck, Graham; Lenkov, Olga D.; Donig, Jessica; Nejadnik, Hossein; Messing, Solomon; Derugin, Nikita; Chan, Ray Chun-Fai; Gaur, Amitabh; Sennino, Barbara; McDonald, Donald M.; Kempen, Paul J.; Tikhomirov, Grigory A.; Rao, Jianghong

    2013-01-01

    Transplanted mesenchymal stem cells (MSCs) could be detected and tracked with MR imaging, if the donor is treated with an intravenous injection of the Food and Drug Administration–approved iron supplement ferumoxytol prior to MSC harvesting.

  15. Utility of screening computed tomography of chest, abdomen and pelvis in patients after heart transplantation

    International Nuclear Information System (INIS)

    Dasari, Tarun W.; Pavlovic-Surjancev, Biljana; Dusek, Linda; Patel, Nilamkumar; Heroux, Alain L.

    2011-01-01

    Introduction: Malignancy is a late cause of mortality in heart transplant recipients. It is unknown if screening computed tomography scan would lead to early detection of such malignancies or serious vascular anomalies post heart transplantation. Methods: This is a single center observational study of patients undergoing surveillance computed tomography of chest, abdomen and pelvis atleast 5 years after transplantation. Abnormal findings, included pulmonary nodules, lymphadenopathy and intra-thoracic and intra-abdominal masses and vascular anomalies such as abdominal aortic aneurysm. The clinical follow up of each of these major abnormal findings is summarized. Results: A total of 63 patients underwent computed tomography scan of chest, abdomen and pelvis at least 5 years after transplantation. Of these, 54 (86%) were male and 9 (14%) were female. Mean age was 52 ± 9.2 years. Computed tomography revealed 1 lung cancer (squamous cell) only. Non specific pulmonary nodules were seen in 6 patients (9.5%). The most common incidental finding was abdominal aortic aneurysms (N = 6 (9.5%)), which necessitated follow up computed tomography (N = 5) or surgery (N = 1). Mean time to detection of abdominal aortic aneurysms from transplantation was 14.6 ± 4.2 years. Mean age at the time of detection of abdominal aortic aneurysms was 74.5 ± 3.2 years. Conclusion: Screening computed tomography scan in patients 5 years from transplantation revealed only one malignancy but lead to increased detection of abdominal aortic aneurysms. Thus the utility is low in terms of detection of malignancy. Based on this study we do not recommend routine computed tomography post heart transplantation.

  16. Tomography methods for diagnostic examination of cerebrovascular disease: a comparative evaluation of SPECT, PET and MR/CT findings

    International Nuclear Information System (INIS)

    Reiche, W.; Kaiser, H.J.; Weiller, C.; Altehoefer, C.; Buell, U.; Isensee, C.

    1991-01-01

    Single Photon Emissions Computerized Tomography (SPECT), Positron Emissions Tomography (PET), Magnetic Resonance Tomography (MR), and Transmission Computerized Tomography (CT) complement each other and lead to a consideration of the cerebrovascular disease under patho-physiological aspects. Indications for the combined application of functionally oriented (SPECT/PET) and morphologically oriented (CT/MR) examination methods with cerebrovascular disease are presented. (orig./MG) [de

  17. MR angiography of in situ and transplanted renal arteries

    International Nuclear Information System (INIS)

    Smith, H.J.; Bakke, S.J.

    1993-01-01

    Three-dimensional (3D) time-of-flight (TOF) MR angiography (MRA) was performed in 34 patients with suspected renal artery disease. In situ (i.e., nontransplanted) renal arteries were studied with MRA in 14 patients. Of these, 12 had conventional angiography for comparison. Twenty-four MRAs of transplanted renal arteries were obtained in 20 patients; 8 of these had angiography as well. Significant stenoses of in situ renal arteries were diagnosed with a sensitivity of 100% and a specificity of 95%. The stenoses were all proximal; 3D TOF MRA proved inadequate for depiction of peripheral renal arteries. MRA and angiography showed good agreement between findings in 7 of 8 patients with renal transplants. In one patient with a renal transplant, MRA showed a significant stenosis of the arterial anastomosis which appeared completely normal at i.a. DSA, indicating that findings at MRA still need to be confirmed by more established alternative methods. (orig.)

  18. MR imaging in congenital complicated anterior body wall defects; MRT von komplizierten angeborenen Bauchwanddefekten

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, M.; Scharitzer, M. [Universitaetsklinik fuer Radiodiagnostik, AKH-Wien (Austria); Pumberger, W. [Universitaetsklinik fuer Kinderchirurgie, AKH-Wien (Austria); Patzak, B. [Pathologisch-anatomisches Museum im Narrenturm, AKH-Wien (Austria)

    2003-04-01

    Introduction: Aim of this study was to estimate the value of postmortem MR imaging in evaluation of specimen with congenital anterior body wall defects of the museum of pathologic-anatomy. Material and Methods: We examined 19 specimen with a 1.5 Tesla unit by using T{sub 1}- and T{sub 2}-weighted sagittal and coronal sequences. In some specimen additional axial T{sub 2}-weighted images were obtained. We evaluated the site of the bowel, the liver, the heart and presence of associated disorders. Results: The bowels were completely intraabdominal, in two specimen, completely extraabdominal in 12 specimen and in 5 specimen intra- and extraabdominal. The liver was in two specimen completely extraabdominal/in 12 completely intracorporal, and in 5 specimen intra- and extraabdominal. In 5 cases the heart was located extraanatomically. In 12 specimen we found disorders of the spine and the extremities. Congenital disorders of the kidneys were found in 6 specimen. Conclusion: MR imaging is of great value in the assessment of congenital anterior body wall defects. In the light of ultrafast sequences the role of fetal MR imaging in the evaluation of congenital body wall defects may be mandatory in the future. (orig.) [German] Einleitung: Wir nutzten die Sammlung des pathologisch-anatomischen Museums in Wien, um die Wertigkeit der MRT zur Beschreibung von angeborenen vorderen Bauchwanddefekten und deren assoziierten Erkrankungen zu bestimmen. Material und Methode: Wir untersuchten 19 Exponate mit einem 1,5-Tesla-Geraet unter Verwendung von sagittalen und koronalen T{sub 1}- und T{sub 2}-gewichteten Sequenzen. Ausgewertet wurden die Lage des Darmes, der Leber, des Herzens und assoziierte Missbildungen. Ergebnisse: Der Darm lag in zwei Faellen intraabdominal, zur Gaenze extraabdominal in 12 Faellen, intra- und extraabdominal in 5 Faellen. Die Leber war in zwei Exponaten zur Gaenze extraabdominal, in 5 intra- und extraabdominal und in 12 Exponaten intraabdominal. Assoziiert waren

  19. Advantages of gadobenate dimeglumine-enhanced MR cholangiography in the diagnosis of post-liver transplant bile leakage.

    Science.gov (United States)

    Fontarensky, M; Montoriol, P-F; Buc, E; Poincloux, L; Petitcolin, V; Da Ines, D

    2013-04-01

    To assess the value of magnetic resonance cholangiography with gadobenate dimeglumine (Gd-BOPTA) where there is a suspicion of bile leakage in the post-liver transplant patient. Eight patients who had undergone a liver transplant underwent 14 MR cholangiograms, five of whom presented bile leakage while the other three had no biliary system complications. The results were compared to conventional bile duct opacification (by endoscopy or t-tube cholangiogram). The analysis covered whether there was opacification of the common bile duct and intrahepatic bile ducts on T1-weighted sequences after an injection of Gd-BOPTA on delayed biliary excretion phase sequences that were carried out on average 74 min after the injection. Enhancing perihepatic collections were also taken into account. Opacification of the bile ducts on delayed-phase MR cholangiogram sequences was always seen in the absence of bile leakage, and was never found when leakage was present. Enhancing perihepatic collections pointed to bile leakage every time. Gd-BOPTA-enhanced MR cholangiography is a simple and non-invasive technique for detecting bile leakage in the post-liver transplant patient. Copyright © 2013 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  20. Digital Signal Processor for Data Transfer and Processing in MR Tomography

    Czech Academy of Sciences Publication Activity Database

    Smékal, Z.; Gescheidtová, E.; Bartušek, Karel; Dokoupil, Zdeněk

    2005-01-01

    Roč. 13, č. 1 (2005), s. 39-48 ISSN 1738-6438 R&D Projects: GA AV ČR(CZ) IAA2065201 Keywords : MR tomography * DSP96002 * preemphasis filter * communication interface Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  1. MR implant labelling and its use in clinical MRI practice; MR-Implantatkennzeichnungen und ihre Anwendung in der klinischen MRT-Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenweg, M. [Krankenhaus Martha-Maria Halle-Doelau, Institut fuer Radiologie, Halle (Saale) (Germany); Schaefers, G. [MR:comp GmbH, Gelsenkirchen (Germany)

    2015-08-15

    Before a magnetic resonance imaging (MRI) examination, implants in patients must be cleared for MR safety in order to exclude the risk of possible severe injuries and implant malfunction in an MR environment. The general contraindication for measurements of patients with implants still applies; however, in the recent past a way has been found to legally circumvent this contraindication. For this purpose special conditions are required: explicit implant identification and the original manufacturer's labelling are necessary, the required conditions for conditionally MR safe implants must be assured and a risk-benefit analysis with appropriate explanation to the patient has to be performed. This process can be very complex as the implants are often poorly documented and detailed information on the implant MR labelling is also often outdated or not easy to interpret. This article provides information about legal and normative principles of MR measurement of patients with implants. The possible physical interactions with implants will be briefly dealt with as well as possible strategies for better identification and investigation of implants and MR labelling. General approaches for minimizing the risk will be discussed using some examples. The second part deals with the content of MR implant labelling and the current test standards. Furthermore, the additional information from the operating instructions of the MR scanner that are necessary for the interpretation of the MR implant labelling, will be explained. The article concludes with an explanation of the current pattern for MR labelling of implants from the U.S. Food and Drug Administration (FDA) and an exemplary application. (orig.) [German] Implantate in Patienten muessen vor einer MR-Untersuchung auf MR-Sicherheit abgeklaert werden, um moegliche z. T. schwere Verletzungen und Implantatfehlfunktionen in einer MR-Umgebung weitestgehend auszuschliessen. Es gilt unveraendert die generelle Kontraindikation von

  2. Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report.

    Science.gov (United States)

    Wypych-Klunder, Katarzyna; Adamowicz, Andrzej; Lemanowicz, Adam; Szczęsny, Wojciech; Włodarczyk, Zbigniew; Serafin, Zbigniew

    2014-01-01

    An aim of this study was to assess the feasibility of DWI in the early period after kidney transplantation. We also aimed to compare ADC and eADC values in the cortex and medulla of the kidney, to estimate image noise and variability of measurements, and to verify possible relation between selected labolatory results and diffusion parameters in the transplanted kidney. Examinations were performed using a 1.5 T MR unit. DWI (SE/EPI) was performed in the axial plane using b-values of 600 and 1000. ADC and eADC measurements were performed in four regions of interest within the renal cortex and in three regions within the medulla. Relative variability of results and signal-to-noise ratio (SNR) were calculated. The analysis included 15 patients (mean age 52 years). The mean variability of ADC was significantly lower than that of eADC (6.8% vs. 10.8%, respectively; p30 ml/min./1.73 m(2) (p<0.05). Diffusion-weighted imaging of transplanted kidneys is technically challenging, especially in patients in the early period after transplantation. From a technical point of view, the best quality parameters offer quality ADC measurement in the renal cortex using b1000. ADC and eADC values in the renal cortex measured at b1000 present a relationship with eGFR.

  3. Evaluation of Porcine Pancreatic Islets Transplanted in the Kidney Capsules of Diabetic Mice Using a Clinically Approved Superparamagnetic Iron Oxide (SPIO) and a 1.5T MR Scanner

    International Nuclear Information System (INIS)

    Kim, Hoe Suk; Kim, Hyoung Su; Park, Kyong Soo; Moon, Woo Kyung

    2010-01-01

    To evaluate transplanted porcine pancreatic islets in the kidney capsules of diabetic mice using a clinically approved superparamagnetic iron oxide (SPIO) and a 1.5T MR scanner. Various numbers of porcine pancreatic islets labeled with Resovist, a carboxydextran-coated SPIO, were transplanted into the kidney capsules of normal mice and imaged with a 3D FIESTA sequence using a 1.5T clinical MR scanner. Labeled (n = 3) and unlabeled (n = 2) islets were transplanted into the kidney capsules of streptozotocin-induced diabetic mice. Blood glucose levels and MR signal intensities were monitored for 30 days post-transplantation. There were no significant differences in viability or insulin secretion between labeled and unlabeled islets. A strong correlation (γ 2 > 0.94) was evident between the number of transplanted islets and T 2 relaxation times quantified by MRI. Transplantation with labeled or unlabeled islets helped restore normal sustained glucose levels in diabetic mice, and nephrectomies induced the recurrence of diabetes. The MR signal intensity of labeled pancreatic islets decreased by 80% over 30 days. The transplantation of SPIO-labeled porcine islets into the kidney capsule of diabetic mice allows to restore normal glucose levels, and these islets can be visualized and quantified using a 1.5T clinical MR scanner

  4. In vivo MR imaging of nanometer magnetically labeled bone marrow stromal cells transplanted via portal vein in rat liver

    International Nuclear Information System (INIS)

    Wang Ping; Wang Jianhua; Yan Zhiping; Hu Meiyu; Xu Pengju; Zhou Meiling; Ya Fuhua; Fan Sheung-tat; Luk John-m

    2006-01-01

    Objective: To evaluate in vivo magnetic resonance imaging with a conventional 1.5-T system for tracking of intra-portal vein transplantation nanometer magnetically labeled BMSCs in rat liver. Methods: BMSCs were isolated from 5 SD rats bone marrow with the density gradient centrifugation method. Then BMSCs were labeled with nanometer superpara-magnetic iron oxide and transfection agent. Cell labeling efficiency was assessed with determination of the percentage of Peris Prussian blue stain. Then BMSCs transplanted into normal rats' livers via portal vein. The receipts were divided into 5 groups ,including sham control,2 h ,3 d,7 d and 2 w after transplantation. Follow-up serial T 1 WI,T 2 WI and T 2 * -weighted gradient- echo MR imaging were performed at 1.5 T MRI system. MR imaging findings were compared with histology. Results: Cell labeling efficiency was more than 95% by Perls Prussian blue stain. After transplantation of labeled BMSCs via portal vein, liver's had diffuse granular signal intensity appearance in T 2 * WI MRI. Cells were detected for up to 2 w in receipts' liver's. At histologic analysis, signal intensity loss correlated with iron-loaded cells. Conclusion: MR imaging could aid in monitoring of magnetically labeled BMSCs administered via portal vein in vivo. (authors)

  5. Comparison between T2-weighted MR and contrast-enhanced MR cholangiography in the evaluation of biliary anatomy in liver transplant donor candidates

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Wu Chunnan; Dong Yuru; Dong Yue; Zhang Huiqing; Zang Yunjin

    2008-01-01

    Objective: To compare conventional T 2 -weighted MR cholangiography (T 2 WI-MRC) with gadobenate dimeglumine enhanced T 1 -weighted MR cholangiography(CE-MRC) for evalution of biliary anatomy in liver transplant donor candidates. Methods: Thirty-two healthy liver transplant donor candidates were examined with two MR cholangiographic methods. For T 2 WI-MRC, a three-dimensional turbo spin-echo sequence and oblique coronal heavily T 2 -weighted thick-slab turbo spin-echo imaging sequence were performed. For CE-MRC, three-dimensional fat-suppressed spoiled gradient-echo sequences were performed, with a time delay of 60 minutes following the administration of gadobenate dimeglumine. To compare the depiction of biliary duct anatomy and the artifact caused by intestinal liquid and breathing between the two methods. Intraoperative cholangiography was the reference-standard examination. Results: The both methods depicted the biliary anatomy correctly in all 9 cases. The both methods showed the third branches of intrahepatic biliary duct clearly. T 2 WI-MRC showed interhepatic biliary duct before the third branches in 28 cases (87.5%), CE-MRC showed the same finding in 14 eases (43.8%). T 2 WI-MRC showed common bile ducts intermitantly in 2 cases, which were normal in CE-MRC and intraoperative cholangiography. Intestinal liquid affected the image quality of biliary duct in 6 cases (18.8%) performed with T 2 WI-MRC, but none with CE-MRC. The artifacts caused by breathing were not obvious in the either method. Conclusion: T 2 WI-MRC and CE-MRC both can be used to evaluate biliary anatomy of liver transplant donor candidates, but CE-MRC appears to be more accurate than T 2 WI-MRC. (authors)

  6. Assessment of hemodynamic changes in patients with renal artery stenosis by means of the cine MR phase-contrast technique; Einstufung haemodynamischer Veraenderungen bei Nierenarterienstenosen mittels MR-Cine-Phasenkontrastflussmessungen

    Energy Technology Data Exchange (ETDEWEB)

    Schoenberg, S.O.; Knopp, M.V.; Bock, M.; Essig, M.; Hawighorst, H.; Zuna, I.; Schad, L.; Kaick, G. van [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie; Kallinowski, F.; Allenberg, J.R. [Chirurgische Universitaetsklinik, Heidelberg (Germany). Sektion Gefaesschirurgie; Just, A. [Heidelberg Univ. (Germany). 1. Physiologisches Inst.

    1997-08-01

    Purpose: To evaluate the use of high-temporal resolution cine MR phase-contrast flow measurements for assessment of flow dynamics in renal artery stenosis (RAS). Material and methods: In a dog model, cine MR flow measurements were validated by comparing the MR flow data to an invasive transit-time ultrasound reference technique for different degrees of RAS. Cardiac-gated MR flow curves were recorded in 56 renal arteries of 28 patients with a temporal resolution of at least 32 ms. In all cases RAS was confirmed by digital subtraction angiography (DSA). Abnormalities of flow dynamics were assessed in the calculated flow curves using the MR parameters mean flow, maximum velocity, and time to systolic maximum. Results: By means of the MR blood flow paremeters high-grade stenoses (>50%, n=23) were detected with sensitivity of 100% and specificity of 94% with reference to DSA. The overall differentiation between stenoses (n=37) and non-stenosed vessels (n=19) revealed a sensitivity of 87% and a specificity of 100%. Conclusion: Analysis of cardiac-gated MR flow curves provides a non-invasive method to assess the hemodynamic significance of RAS and thus allows a functional evaluation in relation to the morphologic characteristics of the stenosis. (orig.) [Deutsch] Ziel der Untersuchung war die Beurteilung der Haemodynamik bei Nierenarterienstenosen mittels Cine-MR-Phasenkontrastflussmessungen. In einem Hundemodell wurde die Cine-MR-Flussmessung validiert, indem fuer unterschiedliche Stenosegrade Vergleichsmessungen mit einer invasiven Transitzeit-Ultraschallreferenztechnik durchgefuehrt wurden. EKG-getriggerte MR-Flusskurven wurden bei 28 Patienten in 56 Nierenarterien mit einer Zeitaufloesung von mindestens 32 ms aufgenommen. Alle Nierenarterienstenosen wurden mittels digitaler Subtraktionsangiographie gesichert. Stoerungen in der renalen Haemodynamik wurden anhand der berechneten MR-Flusskurven mit Hilfe der Parameter `Mittelfluss, `maximale Geschwindigkeit` und `Zeit

  7. Imaging characteristics of toxoplasmosis encephalitis after bone marrow transplantation: report of two cases and review of the literature

    International Nuclear Information System (INIS)

    Mueller-Mang, C.; Mang, T.G.; Thurnher, M.M.; Kalhs, P.

    2006-01-01

    Toxoplasmosis encephalitis is a severe, but often misdiagnosed complication in patients after bone marrow transplantation (BMT). We describe the unique computed tomography (CT) and magnetic resonance (MR) imaging features of cerebral toxoplasmosis in two bone marrow recipients and compare them to the cases in the literature. To our knowledge, this is the first report analyzing the appearance of cerebral toxoplasmosis on diffusion-weighted MR imaging (DWI). (orig.)

  8. Imaging characteristics of toxoplasmosis encephalitis after bone marrow transplantation: report of two cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Mang, C.; Mang, T.G.; Thurnher, M.M. [University Hospital Vienna, Department of Radiology, Vienna (Austria); Kalhs, P. [University Hospital Vienna, Department of Internal Medicine, Vienna (Austria)

    2006-02-15

    Toxoplasmosis encephalitis is a severe, but often misdiagnosed complication in patients after bone marrow transplantation (BMT). We describe the unique computed tomography (CT) and magnetic resonance (MR) imaging features of cerebral toxoplasmosis in two bone marrow recipients and compare them to the cases in the literature. To our knowledge, this is the first report analyzing the appearance of cerebral toxoplasmosis on diffusion-weighted MR imaging (DWI). (orig.)

  9. Bone marrow MR imaging as predictors of outcome in hemopoietic stem cell transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Jun; Cheng, Li-Na; Duan, Xiao-Hui; Liang, Bi-Ling [Sun Yat-sen University, Department of Radiology, Guangzhou, Guangdong (China); Second Affiliated Hospital, Guangzhou, Guangdong (China); Griffith, James F. [Chinese University of Hong Kong, Prince of Wales Hospital, Department of Diagnostic Radiology and Organ Imaging, Shatin, Hong Kong SAR (China); Xu, Hong-Gui [Sun Yat-sen University, Department of Pediatrics, Guangzhou, Guangdong (China); Second Affiliated Hospital, Guangzhou, Guangdong (China)

    2008-09-15

    The purpose of this study is to investigate the role of femoral marrow MR imaging as predictor of outcome for hemopoietic stem cell transplantation (HSCT) in beta-thalassemia major. MR imaging of the proximal femur, including T1- and T2-weighted spin echo and short-tau inversion recovery and in-phase and out-of-phase fast field echo images, was prospectively performed in 27 thalassemia major patients being prepared for HSCT. The area of red marrow and its percentage of the proximal femur were measured, and the presence of marrow hemosiderosis was assessed. Age-adjusted multivariate logistic regression was used to determine the relationship between red marrow area percentage and marrow hemosiderosis and HSCT outcome. Red area percentage were less in patients with successful (90.25{+-}4.14%) compared to unsuccessful transplants (94.54% {+-}2.93%; p=0.01). Red marrow area percentage correlated positively with duration of symptoms(r=0.428, p=0.026) and serum ferritin (r=0.511, p=0.006). In multivariate-adjusted logistic regression analyses, red marrow area percentage was significantly inversely associated with successful HSCT (OR=1.383, 95% CI: 1.059-1.805, p=0.005). Marrow hemosidersosis and duration of sympotms and serum ferritin were not associated with HSCT outcome(p=0.174, 0.974, 0.762, respectively). Red marrow area percentage of proximal femur on MR imaging is a useful predictor of HSCT outcome. (orig.)

  10. Bone marrow MR imaging as predictors of outcome in hemopoietic stem cell transplantation

    International Nuclear Information System (INIS)

    Shen, Jun; Cheng, Li-Na; Duan, Xiao-Hui; Liang, Bi-Ling; Griffith, James F.; Xu, Hong-Gui

    2008-01-01

    The purpose of this study is to investigate the role of femoral marrow MR imaging as predictor of outcome for hemopoietic stem cell transplantation (HSCT) in beta-thalassemia major. MR imaging of the proximal femur, including T1- and T2-weighted spin echo and short-tau inversion recovery and in-phase and out-of-phase fast field echo images, was prospectively performed in 27 thalassemia major patients being prepared for HSCT. The area of red marrow and its percentage of the proximal femur were measured, and the presence of marrow hemosiderosis was assessed. Age-adjusted multivariate logistic regression was used to determine the relationship between red marrow area percentage and marrow hemosiderosis and HSCT outcome. Red area percentage were less in patients with successful (90.25±4.14%) compared to unsuccessful transplants (94.54% ±2.93%; p=0.01). Red marrow area percentage correlated positively with duration of symptoms(r=0.428, p=0.026) and serum ferritin (r=0.511, p=0.006). In multivariate-adjusted logistic regression analyses, red marrow area percentage was significantly inversely associated with successful HSCT (OR=1.383, 95% CI: 1.059-1.805, p=0.005). Marrow hemosidersosis and duration of sympotms and serum ferritin were not associated with HSCT outcome(p=0.174, 0.974, 0.762, respectively). Red marrow area percentage of proximal femur on MR imaging is a useful predictor of HSCT outcome. (orig.)

  11. Bone-marrow MR imaging before and after autologous marrow transplantation in lymphoma patients without known bone-marrow involvement

    International Nuclear Information System (INIS)

    Lien, H.H.; Blomlie, V.; Blystad, A.K.; Holte, H.; Kvaloey, S.; Langholm, R.

    1997-01-01

    Purpose: To study lumbar bone marrow by means of MR imaging before and after bone-marrow transplantation in lymphoma patients. Particular emphasis was paid to heterogeneity and to focal manifestations, i.e. appearances that could simulate tumor. Material and Methods: Twenty-two patients who were disease-free for a minimum of 30 months after transplantation were studied in 107 MR examinations. Two radiologists visually evaluated coronal T1-weighted and short inversion time inversion-recovery (STIR) images. Results: T1-weighted images demonstrated a more heterogeneous marrow after transplantation than before it. Sharply defined focal low signal intensity areas appeared on this sequence in 5 (23%) of the 22 patients at between 21 and 60 weeks after transplantation. The mean age of these 5 patients was 48.4 years (range 42-54 years). The difference in age between these 5 patients and the remaining 17 patients, who had a mean age of 33.4 years (range 14-51 years), was statistically significant (p<0.01, Student's t-test, 2-sided test). Conclusion: Sharply defined focal low signal intensity areas may be seen on T1-weighted images of bone marrow in patients who are in complete remission after transplantation, particularly in those aged over 40-45 years. (orig.)

  12. A 31-channel MR brain array coil compatible with positron emission tomography.

    Science.gov (United States)

    Sander, Christin Y; Keil, Boris; Chonde, Daniel B; Rosen, Bruce R; Catana, Ciprian; Wald, Lawrence L

    2015-06-01

    Simultaneous acquisition of MR and positron emission tomography (PET) images requires the placement of the MR detection coil inside the PET detector ring where it absorbs and scatters photons. This constraint is the principal barrier to achieving optimum sensitivity on each modality. Here, we present a 31-channel PET-compatible brain array coil with reduced attenuation but improved MR sensitivity. A series of component tests were performed to identify tradeoffs between PET and MR performance. Aspects studied include the remote positioning of preamplifiers, coax size, coil trace size/material, and plastic housing. We then maximized PET performance at minimal cost to MR sensitivity. The coil was evaluated for MR performance (signal to noise ratio [SNR], g-factor) and PET attenuation. The coil design showed an improvement in attenuation by 190% (average) compared with conventional 32-channel arrays, and no loss in MR SNR. Moreover, the 31-channel coil displayed an SNR improvement of 230% (cortical region of interest) compared with a PET-optimized 8-channel array with similar attenuation properties. Implementing attenuation correction of the 31-channel array successfully removed PET artifacts, which were comparable to those of the 8-channel array. The design of the 31-channel PET-compatible coil enables higher sensitivity for PET/MR imaging, paving the way for novel applications in this hybrid-imaging domain. © 2014 Wiley Periodicals, Inc.

  13. Direct MR Arthrography of the wrist in comparison with Arthroscopy: A prospective study on 125 patients; Direkte MR-Arthrographie des Handgelenks im Vergleich zur Arthroskopie: Eine prospektive Studie an 125 Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R.; Christopoulos, G.; Coblenz, G.; Froehner, S. [Institut fuer Diagnostische und Interventionelle Radiologie der Herz- und Gefaessklinik GmbH, Bad Neustadt an der Saale (Germany); Meier, R.; Lanz, U.; Krimmer, H. [Klinik fuer Handchirurgie GmbH, Bad Neustadt an der Saale (Germany)

    2003-07-01

    attitude of caution must be adopted in diagnosing lesions of the articular cartilage of the wrist. (orig.) [German] Ziel: Bestimmung der diagnostischen Genauigkeit der direkten MR-Arthrographie in der Diagnostik von intraartikulaeren Pathologien des Handgelenks. Material und Methoden: Prospektiv und geblindet wurden 125 Patienten mit karpaler Beschwerdesymptomatik am Tag vor einer Arthroskopie mittels direkter Arthro-MR-Tomographie untersucht. Nach radiokarpaler und mediokarpaler Injektion eines Kontrastmittelgemisches wurden an einem 1,5-Tesla-Scanner folgende Sequenzen akquiriert: koronal T1-w SE, koronal T1-w SE fettsaturiert, koronal T1-/T2*-DESS-3D und sagittal T2*-w MEDIC. Die MR-tomographischen Befunde wurden in einer statistischen Analyse mit denen der Arthroskopie verglichen (SEN=Sensitivitaet, SPE=Spezifitaet, PPV=positiver Vorhersagewert, NPV=negativer Vorhersagewert, ACC=Genauigkeit). Ergebnisse: Im Vergleich mit der Arthroskopie als diagnostischem Goldstandard wies die MR-Arthroskopie folgende diagnostische Kenndaten auf: Detektion von TFCC-Laesionen: SEN 97,1%, SPE 96,4%, PPV 97,1%, NPV 96,4%, ACC 96,8%. Fuer den Nachweis kompletter Rupturen des Lig. scapholunatum: SEN 91,7%, SPE 100%, PPV 100%, NPV 99,1%, ACC 99,2% (Teilrupturen: SEN 62,5%, SPE 100%, PPV 100%, NPV 94,8%, ACC 95,2%). Erkennen von Laesionen des hyalinen Gelenkknorpels: SEN 84,2%, SPE 96,2%, PPV 80%, NPV 97,1%, ACC 94,4%. Im Gesamtkollektiv fanden sich nur 3 Laesionen des Lig. lunotriquetrum. Schlussfolgerungen: Fuer das Erkennen intraartikulaerer Pathologien des Handgelenks ist die MR-Tomographie in direkter Arthrographie-Technik gut geeignet, da sie bessere diagnostische Ergebnisse liefert im Vergleich zu den Literaturmitteilungen der Nativuntersuchung. Mit einer Genauigkeit von deutlich ueber 90% ist die Indikation zur direkten MR-Arthrographie bei klinisch begruendetem Verdacht auf eine Komplettruptur des skapholunaeren Ligaments oder des ulnokarpalen Komplexes gegeben. (orig.)

  14. MR-urography and CT-urography: principles, examination techniques, applications; MR-Urographie und CT-Urographie: Prinzipien, Untersuchungstechniken, Anwendungsmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Adam, G. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Staatz, G.; Wildberger, J. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2003-02-01

    MR-urography (MRU) and CT-urography (CTU) provide refined imaging of the upper urinary tract not achievable with conventional intravenous urography (IVU). The traditional MR-urographic technique utilizes unenhanced, heavily T{sub 2}-weighted turbo spin-echo sequences for obtaining static fluid images of the urinary tract independent of the excretory renal function. T{sub 2}-weighted MR-urograms have proved to be excellent in visualizing the dilated urinary tract, even in non-excreting kidneys. In contrast, T{sub 1}-weighted MRU reflects the excretory renal function and displays the urine flow through the upper tract after renal excretion of an intravenously administered gadolinium chelate. The gadolinium-enhanced urine is visualized with fast T{sub 1}-weighted 3D-gradient-echo sequences. The combination of gadolinium and low-dose furosemide (5-10 mg) is the key for achieving a uniform distribution of gadolinium in the collecting system and for avoiding susceptibility artifacts (T{sub 2}*-effects) in the urine. T{sub 1}-weighted excretory MRU provides impressive urograms of both non-dilated and obstructed collecting systems in patients with normal or moderately impaired renal function. Multislice-CT-urography (MS-CTU) is also an excretory urography like T{sub 1}-weighted MRU. Furthermore, MS-CTU can be combined with low-dose furosemide for accelerated passage of excreted contrast material obviating the need for abdominal compression. CT-urography is limited by its radiation burden and the nephrotoxicity of radiographic contrast media. Combining MRU or MS-CTU with conventional MRI or CT offers several applications, e.g., diagnosis of intrinsic and extrinsic tumors. Meanwhile, MRU has replaced IVU in pediatric uroradiology and is also recommended for the assessment of renal transplants. MS-CTU may provide valuable information in chronic urolithiasis, especially if associated with a distorted urinary tract anatomy. Both MRU and MS-CTU will play an important role in

  15. Functional MR urography in infants and children. Indications, techniques and requirements; Funktionelle MR-Urografie (fMRU) bei Kindern und Jugendlichen. Indikationen, Techniken und Anforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Martin; Mentzel, Hans-Joachim [Universitaetsklinikum Jena (Germany). Sektion Paediatrische Radiologie; Darge, Kassa [Children' s Hospital, Philadelphia, PA (United States). Section ' ' Body Imaging' ' ; John, Ulrike [Universitaetsklinikum Jena (Germany). Sektion Paediatrische Nephrologie

    2013-03-15

    Congenital anomalies of the kidney and urinary tract (CAKUT) need to be diagnosed correctly in early life in order to avoid the need for dialysis and renal transplantation. Traditionally, X-ray, fluoroscopy, computed tomography, and ultrasonography are the imaging methods to assess kidneys and the urinary tract. In infants and children, however, ultrasonography is the imaging method of first choice. In order to analyse the renal, to be more precise, the split renal function, MR urography has the potential for giving that information. More easily, information on morphology and dynamics of urinary flow in the upper renal tract can be obtained, too. Up to now, there is no commercial solution for obtaining split renal function with MR machines, however, two freeware solutions exist (''CHOP-fMRU'' and ''MR Urography''), that fill the gap. This article gives detailed information on patient selection, patient preparation, dedicated MR sequence technique, moreover discusses installation, use, and interpretation of the functional part using the ''CHOP-fMRU'' software. (orig.)

  16. USPIO-enhanced MR imaging of macrophage infiltration in native and transplanted kidneys: initial results in humans

    Energy Technology Data Exchange (ETDEWEB)

    Hauger, Olivier; Grenier, Nicolas [Service d' Imagerie Diagnostique et Therapeutique de l' Adulte, Groupe Hospitalier Pellegrin, Bordeaux Cedex (France); Laboratoire d' Imagerie Moleculaire et Fonctionnelle, ERT CNRS/Universite Victor Segalen Bordeaux 2, Bordeaux (France); Deminere, Colette [Service d' Anatomo-pathologie, Groupe Hospitalier Pellegrin, Bordeaux (France); Lasseur, Catherine; Delmas, Yahsou; Merville, Pierre; Combe, Christian [Departement de Nephrologie, Groupe Hospitalier Pellegrin, Bordeaux (France)

    2007-11-15

    The purpose of this study was to evaluate the detection and characterization of macrophage infiltration in native and transplanted kidneys using ultrasmall superparamagnetic iron oxide particles (USPIO). Among 21 patients initially enrolled, 12 scheduled for renal biopsy for acute or rapidly progressive renal failure (n = 7) or renal graft rejection (n = 5) completed the study. Three magnetic resonance (MR) sessions were performed with a 1.5-T system, before, immediately after and 72 h after i.v. injection of USPIO at doses of 1.7-2.6 mg of iron/kg. Signal intensity change was evaluated visually and calculated based on a region of interest (ROI) positioned on the kidney compartments. Histological examination showed cortical macrophage infiltration in four patients (>5 macrophages/mm{sup 2}), two in native kidneys (proliferative extracapillary glomerulonephritis) and two in transplants (acute rejection). These patients showed a 33 {+-} 18% mean cortical signal loss on T2*-weighted images. In the remaining eight patients, with <5 macrophages/mm{sup 2}, there was no cortical signal loss. However, in three of these, presenting with ischemic acute tubular necrosis, a strong (42 {+-} 18%) signal drop was found in the medulla exclusively. USPIO-enhanced MR imaging can demonstrate infiltration of the kidneys by macrophages both in native and transplanted kidneys and may help to differentiate between kidney diseases. (orig.)

  17. Diffusion-weighted MR imaging of transplanted kidneys: Preliminary report

    International Nuclear Information System (INIS)

    Wypych-Klunder, Katarzyna; Adamowicz, Andrzej; Lemanowicz, Adam; Szczęsny, Wojciech; Włodarczyk, Zbigniew; Serafin, Zbigniew

    2014-01-01

    An aim of this study was to assess the feasibility of DWI in the early period after kidney transplantation. We also aimed to compare ADC and eADC values in the cortex and medulla of the kidney, to estimate image noise and variability of measurements, and to verify possible relation between selected labolatory results and diffusion parameters in the transplanted kidney. Examinations were performed using a 1.5 T MR unit. DWI (SE/EPI) was performed in the axial plane using b-values of 600 and 1000. ADC and eADC measurements were performed in four regions of interest within the renal cortex and in three regions within the medulla. Relative variability of results and signal-to-noise ratio (SNR) were calculated. The analysis included 15 patients (mean age 52 years). The mean variability of ADC was significantly lower than that of eADC (6.8% vs. 10.8%, respectively; p<0.0001). The mean variability of measurements performed in the cortex was significantly lower than that in the medulla (6.2% vs. 11.5%, respectively; p<0.005). The mean SNR was higher in the measurements using b600 than b1000, it was higher in ADC maps than in the eADC maps, and it was higher in the cortex than in the medulla. ADC and eADC measured at b1000 in the cortex were higher in the group of the patients with eGFR ≤30 ml/min./1.73 m 2 as compared to patients with eGFR >30 ml/min./1.73 m 2 (p<0.05). Diffusion-weighted imaging of transplanted kidneys is technically challenging, especially in patients in the early period after transplantation. From a technical point of view, the best quality parameters offer quality ADC measurement in the renal cortex using b1000. ADC and eADC values in the renal cortex measured at b1000 present a relationship with eGFR

  18. Interventional MR-Mammography: manipulator-assisted large core biopsy and interstitial laser therapy of tumors of the female breast; Interventionelle MR-Mammographie: Manipulatorgestuetzte Biopsie und interstitielle Lasertherapie von Tumoren der weiblichen Brust

    Energy Technology Data Exchange (ETDEWEB)

    Pfleiderer, S.O.R.; Reichenbach, J.R.; Wurdinger, S.; Marx, C.; Freesmeyer, M.G.; Kaiser, W.A. [Inst. fuer Diagnostische und Interventionelle Radiologie, Friedrich-Schiller-Univ. Jena (Germany); Vagner, J.; Fischer, H. [Inst. fuer Medizintechnik und Biophysik, Forschungszentrum Karlsruhe (Germany); Schneider, A. [Klinik fuer Frauenheilkunde, Friedrich-Schiller-Univ. Jena (Germany)

    2003-07-01

    The present study investigated the clinical application of magnetic resonance (MR)-guided breast interventions, such as manipulator-assisted large core breast biopsy (LCBB) inside a 1.5 T whole-body magnet and MR-guided interstitial laser therapy (ILT). Sixteen patients underwent LCBB and 1 additional patient underwent 4 sessions of ILT of a recurrent undifferentiated lymph node metastasis in the axilla using a Nd-YAG laser (1064 nm). Temperature changes of the tumor tissue during ILT were monitored using phase images of a gradient echo sequence (GRE) (TR/TE/FA = 25/12/30). In 5 patients the biopsy findings were histopathologically confirmed after open surgery. In 3 patients, the biopsy missed one tubular and one ductal carcinoma; one invasive carcinoma was underestimated. Eight patients with benign findings are still in the follow-up period. The heating zone during ILT was well delineated on subtracted phase images. No severe adverse events were observed with LCBB or ILT. MR-guided breast biopsies are feasible with the manipulator system inside a whole-body 1.5 Tesla MR scanner. GRE information is suitable for therapy monitoring during ILT within the tumor. Further studies are necessary to evaluate the accuracy of the manipulator system and the efficacy of ILT in the treatment of breast lesions. (orig.) [German] Die klinische Anwendung MR-gestuetzter Interventionen an der Mamma wie die roboterassistierte Brustbiopsie innerhalb eines Ganzkoerpertomographen oder die kernspintomographisch kontrollierte interstitielle Lasertherapie (ILT) wurden untersucht. 16 Patientinnen unterzogen sich einer Brustbiopsie. Eine weitere Patientin wurde in insgesamt 4 Sitzungen mit einem Nd-YAG-Laser (1064 nm) an einem undifferenzierten axillaeren Lymphknotenrezidiv eines Mammakarzinoms behandelt. Temperaturaenderungen im Tumor waehrend der ILT wurden mit Hilfe von Phasenbildern einer Gradientenechosequenz (GRE) (TR/TE/FA = 25/12/30) visualisiert. Bei 5 Patientinnen wurde der

  19. Evaluation of renal allograft function early after transplantation with diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberger, Ute; Frey, Felix J. [University Hospital of Bern, Department of Nephrology and Hypertension, Bern (Switzerland); Thoeny, Harriet C. [University Hospital of Bern, Department of Radiology, Neuroradiology and Nuclear Medicine, Bern (Switzerland); Binser, Tobias; Boesch, Chris [University Hospital of Bern, Department of Clinical Research, Bern (Switzerland); Gugger, Mathias [University Hospital of Bern, Department of Pathology, Bern (Switzerland); Vermathen, Peter [University Hospital of Bern, Department of Clinical Research, Bern (Switzerland); University Bern, Department of Clinical Research/AMSM, Pavillon 52, Inselspital, P.O. Box 35, Bern (Switzerland)

    2010-06-15

    To determine the inter-patient variability of apparent diffusion coefficients (ADC) and concurrent micro-circulation contributions from diffusion-weighted MR imaging (DW-MRI) in renal allografts early after transplantation, and to obtain initial information on whether these measures are altered in histologically proven acute allograft rejection (AR). DW-MRI was performed in 15 renal allograft recipients 5-19 days after transplantation. Four patients presented with AR and one with acute tubular necrosis (ATN). Total ADC (ADC{sub T}) was determined, which includes diffusion and micro-circulation contributions. Furthermore, diffusion and micro-circulation contributions were separated, yielding the ''perfusion fraction'' (F{sub P}), and ''perfusion-free'' diffusion (ADC{sub D}). Diffusion parameters in the ten allografts with stable function early after transplantation demonstrated low variabilities. Values for ADC{sub T} and ADC{sub D} were (x 10{sup -5} mm{sup 2}/s) 228 {+-} 14 and 203 {+-} 9, respectively, in cortex and 226 {+-} 16 and 199 {+-} 9, respectively, in medulla. F{sub P} values were 18 {+-} 5% in cortex and 19 {+-} 5% in medulla. F{sub P} values were strongly reduced to less than 12% in cortex and medulla of renal transplants with AR and ATN. F{sub P} values correlated with creatinine clearance. DW-MRI allows reliable determination of diffusion and micro-circulation contributions in renal allografts shortly after transplantation; deviations in AR indicate potential clinical utility of this method to non-invasively monitor derangements in renal allografts. (orig.)

  20. Evaluation of renal allograft function early after transplantation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Eisenberger, Ute; Frey, Felix J.; Thoeny, Harriet C.; Binser, Tobias; Boesch, Chris; Gugger, Mathias; Vermathen, Peter

    2010-01-01

    To determine the inter-patient variability of apparent diffusion coefficients (ADC) and concurrent micro-circulation contributions from diffusion-weighted MR imaging (DW-MRI) in renal allografts early after transplantation, and to obtain initial information on whether these measures are altered in histologically proven acute allograft rejection (AR). DW-MRI was performed in 15 renal allograft recipients 5-19 days after transplantation. Four patients presented with AR and one with acute tubular necrosis (ATN). Total ADC (ADC T ) was determined, which includes diffusion and micro-circulation contributions. Furthermore, diffusion and micro-circulation contributions were separated, yielding the ''perfusion fraction'' (F P ), and ''perfusion-free'' diffusion (ADC D ). Diffusion parameters in the ten allografts with stable function early after transplantation demonstrated low variabilities. Values for ADC T and ADC D were (x 10 -5 mm 2 /s) 228 ± 14 and 203 ± 9, respectively, in cortex and 226 ± 16 and 199 ± 9, respectively, in medulla. F P values were 18 ± 5% in cortex and 19 ± 5% in medulla. F P values were strongly reduced to less than 12% in cortex and medulla of renal transplants with AR and ATN. F P values correlated with creatinine clearance. DW-MRI allows reliable determination of diffusion and micro-circulation contributions in renal allografts shortly after transplantation; deviations in AR indicate potential clinical utility of this method to non-invasively monitor derangements in renal allografts. (orig.)

  1. High frame-rate MR-guided near-infrared tomography system to monitor breast hemodynamics

    Science.gov (United States)

    Li, Zhiqiu; Jiang, Shudong; Krishnaswamy, Venkataramanan; Davis, Scott C.; Srinivasan, Subhadra; Paulsen, Keith D.; Pogue, Brian W.

    2011-02-01

    A near-infrared (NIR) tomography system with spectral-encoded sources at two wavelength bands was built to quantify the temporal contrast at 20 Hz bandwidth, while imaging breast tissue. The NIR system was integrated with a magnetic resonance (MR) machine through a custom breast coil interface, and both NIR data and MR images were acquired simultaneously. MR images provided breast tissue structural information for NIR reconstruction. Acquisition of finger pulse oximeter (PO) plethysmogram was synchronized with the NIR system in the experiment to offer a frequency-locked reference. The recovered absorption coefficients of the breast at two wavelengths showed identical temporal frequency as the PO output, proving this multi-modality design can recover the small pulsatile variation of absorption property in breast tissue related to the heartbeat. And it also showed the system's ability on novel contrast imaging of fast flow signals in deep tissue.

  2. Fluorodeoxyglucose positron emission tomography-computed tomography scan in von Hippel-Lindau syndrome: a case report and review of literature

    International Nuclear Information System (INIS)

    Solav, Shrikant; Bhandari, Ritu

    2012-01-01

    Von Hippel-Lindau (VHL) syndrome is a hereditary autosomal dominant disorder caused by defective tumor suppression gene at 3p25-p26. The gene for VHL disease is found on chromosome 3, and is inherited in a dominant fashion. The VHL gene is a tumor suppressor gene. This means that its role in a normal cell is to stop the uncontrolled growth and proliferation. It is characterized by abnormal growth of blood vessels. It strikes the eyes, central nervous system, kidneys, endocrine glands, etc. It predisposes the patient to retinal angiomas, central nervous system hemangioblastoma, renal cell carcinoma (RCC), pheochromocytomas, islet cell tumor of the pancreas, endolymphatic sac tumors, renal, pancreatic, epididymal cysts. We present a case of familial VHL syndrome whose Fluorine 18-fluorodeoxyglucose positron emission tomography-computed tomography scan was truly positive for adrenal pheochromocytoma but was falsely negative for RCC. Review of literature related to this entity is made. (author)

  3. MR imaging of muscle injuries; MRT von Muskelverletzungen

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, Klaus [Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2014-12-15

    Injuries to skeletal muscle are very common particularly in athletes. Besides ultrasound, MR imaging represents the most valuable imaging modality for diagnosis and grading of muscle lesions. This article reviews the examination technique and diagnostic criteria of acute and chronic lesions of skeletal muscle at MR imaging. In addition to the morphology of direct and indirect muscle injuries, MR findings in myositis ossificans and compartment syndrome are discussed as well.

  4. Measurement of hydrogen distributions in iron and steel by means of neutron radiography and tomography; Messung von Wasserstoffverteilungen in Eisen und Stahl mittels Neutronenradiographie und -tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Griesche, Axel; Kannengiesser, Thomas [BAM Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Kardjilov, Nikolay; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB), Berlin (Germany); Schillinger, Burkhard [Technische Univ. Muenchen, Garching (Germany)

    2015-07-01

    In recent years, the optimization of the radiography measuring stations at research reactors and in particular the development of the neutron detectors has enabled the measurement of hydrogen distributions with ever higher spatial resolution at the same time more sensitive detection limit. Compared to iron, hydrogen has a high interaction cross-section for neutrons, and thus allows simple radiographic methods of the two and three dimensional visualization of hydrogen distribution in the structure. This allowed us for the first time the measurement of hydrogen diffusion flows in centimeter-thick steel samples with a temporal resolution of 20 s and the quantitative measurement of hydrogen accumulation of crack edges in hydrogen embrittled iron samples. It was also the first gaseous hydrogen detected in the cavities of the cracks and the pressure can be determined. This new quality of information on the microstructure scale granted unprecedented insights for the investigation of damage mechanisms e.g. in the hydrogen embrittlement. By providing local in-situ information that is not accessible by conventional methods such as carrier gas hot extraction, as well as analyzes can be performed in three dimensions with a spatial resolution of 20-30 μm. This article provides examples that use the spatial and temporal resolution of the neutron radiography and tomography to visualize hydrogen distributions in and around cracks and to quantify. The measurements were conducted at the research reactors BER II of HZB in Berlin and FRM II of teh neutron source Heinz Maier-Leibnitz in Garching. (This article contains PowerPoint slides). [German] In den letzten Jahren hat die Optimierung der Radiographie-Messplaetze an Forschungsreaktoren und hier insbesondere die Weiterentwicklung der Neutronendetektoren die Messung von Wasserstoffverteilungen mit immer hoeherer Ortsaufloesung bei gleichzeitig empfindlicherer Nachweisgrenze ermoeglicht. Wasserstoff besitzt im Vergleich zu Eisen

  5. Magnetic resonance imaging of the transplanted kidney

    International Nuclear Information System (INIS)

    Jennerholm, S.; Backman, U.; Bohman, S.O.; Hemmingsson, A.; Nyman, R.; Uppsala Univ. Hospital; Huddinge Hospital

    1990-01-01

    In this study, long-term renal transplants were investigated with magnetic resonance (MR) imaging, and the results were correlated to histopathology and graft function. Seventeen patients were investigated with MR one to 10 years after transplantation and with simultaneous ultrasonographically guided cortical needle biopsy and function tests. Histopathology included semiquantitative grading of degree of fibrosis and quantitation of ratios of tubular structures to interstitial tissue. The correlation between the histopathological assessment of interstitial fibrosis and graft function was good. Poor differentiation between the renal cortex and the renal medulla at MR imaging was correlated to high degree of interstitial fibrosis in the kidney transplants as well as to reduced graft function. MR examination may thus be of value in the evaluation of long-term renal transplants with chronic functional changes. (orig./MG)

  6. MR-guided focused ultrasound. Current and future applications; MR-gesteuerter fokussierter Ultraschall. Aktuelle und potenzielle Indikationen

    Energy Technology Data Exchange (ETDEWEB)

    Trumm, C.G.; Peller, M.; Clevert, D.A.; Stahl, R.; Reiser, M. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen-Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Napoli, A. [Sapienza Universitaet Rom, Abteilung fuer Radiologie (Department of Radiological Sciences), MRgFUS and Cardiovascular Imaging Unit, Rom (Italy); Matzko, M. [Klinikum Dachau, Abteilung fuer diagnostische und interventionelle Radiologie, Dachau (Germany)

    2013-03-15

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier. (orig.) [German] MRT-gesteuerter hochintensiver fokussierter Ultraschall (MRgFUS bzw. MR-HIFU) ist ein nichtinvasives Verfahren zur praezisen Thermoablation eines Zielgewebes. Bei dieser Methode werden benachbarte Gewebe und Organe geschont. Die Kombination des fokussierten Ultraschalls (FUS) mit der MRT zwecks Planung und Monitoring (nahezu) in Echtzeit sowie zur Erfolgskontrolle von Behandlungen traegt wesentlich zur Sicherheit dieser Methode bei. MRgFUS ist klinisch v. a. zur Behandlung von symptomatischen Uterusmyomen etabliert, gefolgt von der palliativen Ablation von Knochenmetastasen. Weitere vielversprechende Anwendungsgebiete des MRgFUS sind die Adenomyose des Uterus, die Behandlung von Prostata-, Mamma- und Lebertumoren sowie der intrakranielle Einsatz. (orig.)

  7. High-resolution computed tomography findings in pulmonary complications after bone marrow transplantation: iconographic essay

    International Nuclear Information System (INIS)

    Gasparetto, Emerson L.; Ono, Sergio E.; Souza, Carolina A.; Escuissato, Dante L.; Rocha, Gabriela de Melo; Inoue, Cezar; Falavigna, Joao M.; Marchiori, Edson; Universidade Federal, Rio de Janeiro

    2005-01-01

    Bone marrow transplantation has been the treatment of choice for many hematologic diseases. However, pulmonary complications, which may occur in up to 60% of the patients, are the main cause of treatment failure and may be divided in three phases according to the patient's immunity. In the first phase, up to 30 days after the procedure, there is a predominance of non-infectious complications and fungal pneumonia. Viral infections, mainly by cytomegalovirus, are common in the second phase (up to 100 days after bone marrow transplantation). Finally, in the late phase after bone marrow transplantation, non-infectious complications as bronchiolitis obliterans organizing pneumonia and graft-versus-host disease are most commonly seen. The authors present a pictorial essay of the high-resolution computed tomography findings in patients with pulmonary complications after bone marrow transplantation. (author)

  8. Functional-anatomic evaluation of dilated uropathies in children using combined MR-nephrography and MR-urography compared to renal scintigraphy; Funktionell-anatomische Diagnostik dilatierter Uropathien bei Kindern mit kombinierter MR-Nephrographie und MR-Urographie im Vergleich zur renalen Isotopennephrographie

    Energy Technology Data Exchange (ETDEWEB)

    Reither, M. [Abt. fuer bildgebende Diagnostik am Kinderkrankenhaus Park Schoenfeld, Kassel (Germany); Tuerkay, S. [GE Medical Systems Deutschland GmbH, Solingen (Germany)

    2004-02-01

    Purpose: to evaluate MR-tomographic assessment of split renal function and degree of obstruction compared to diuretic renal scintigraphy, and pathoanatomic imaging of the urinary tract as all in one exam. Patients and methods: in a prospective study 62 children, aged 1 month to 9.5 years, mean 2.8 years, underwent diuretic renal scintigraphy and dynamic MR-nephrography at the same day except for 7 patients with a time interval of 1 day. In all patients we did T2w (water-technique) MR-urography additionally. Results: comparing spilt renal function we found a very close correlation in 54 out of 62 patients (correlation coefficient = 0.95). Due to technical failures 8 cases couldn't be calculated. Comparing degrees of obstruction there was an agreement in 57 out of 62 patients, 3 studies were gradually over-, 2 underestimated. All but one morphologic diagnoses in advance obtained by ultrasound and completed by other imaging modalities later on were confirmed MR-urographically. Though correctly imaged the functionless upper moiety in a renal duplication with ureterocele was misinterpreted at a first glance. (orig.) [German] Ziel: Es sollte geprueft werden, ob die Berechnung der seitengetrennten Nierenfunktion, die Bestimmung des Obstruktionsgrades und die pathoanatomische Darstellung des Harntraktes im Vergleich zur Diurese-Szintigraphie in einem Untersuchungsgang MR-tomographisch zuverlaessig moeglich ist. Patienten und Methode: In einer prospektiven Studie wurden bei 62 Kindern im Alter von 1 Monat bis 9,5 Jahren, Mittelwert 2,8 Jahre, ein Diurese-Szintigramm und eine dynamische MR-Nephrographie am gleichen Tag durchgefuehrt; lediglich bei 7 Patienten lag 1 Tag zwischen beiden Untersuchungen. Alle Patienten erhielten zusaetzlich eine T2w-MR-Urographie in ''Wasserbild''-Technik. Ergebnisse: Beim Vergleich der seitengetrennten Nierenfunktion fand sich eine sehr enge Korrelation bei 54 von insgesamt 62 Patienten (Korrelationskoeffizient = 0

  9. Virtual endoscopy of the upper urinary tract based on contrast material-enhanced MR urography data sets; Virtuelle Endoskopie des oberen Harntraktes auf der Basis kontrastangehobener MR-Urographie Datensaetze

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Krombach, G.; Staatz, G.; Kilbinger, M.; Adam, G.B.; Guenther, R.W. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1999-06-01

    Purpose: To investigate the feasibility of reconstructing a virtual endoscopy from MR imaging data sets of the upper urinary tract. Method: The data obtained from 28 contrast-enhanced MR urographic examinations (5 normal; 23 pathologic) were post-processed to reconstruct a virtual ureterorenoscopy (VURS) using a threshold image segmentation. The visualization of the upper urinary tract was based on the acquisition of T{sub 1}-weighted 3D gradient-echo sequences after intravenous administration of gadolinium-DTPA and a prior injection of low-dose furosemide. Results: The employed MR urography technique created in all 28 cases a complete and strong contrast enhancement of the urinary tract. These 3D sequence data allowed the reconstruction of a VURS, even when the collecting system was not dilated. The best accuracy was provided by the MR urography sequences with the smallest voxel size. Moreover, the data acquisition based on a breath-hold technique has proved superior to that using a respiratory gating. Inside the renal pelvis, all calices could be assessed by turning the virtual endoscope in the appropriate direction. The visualization of the ureteral orifices in the bladder was also possible. All filling defects that were diagnosed by MR urography could be evaluated from the endoluminal view using the VURS. The exact characterization of the lesions based only on the assessment of the surface structure was difficult. Conclusion: A virtual endoscopy of the upper urinary tract can be successfully reconstructed using the data sets of high-resolution 3D MR urography sequences. (orig.) [Deutsch] Ziel: Untersuchungen zur Anwendung der virtuellen Endoskopie auf MR-tomographische Datensaetze des oberen Harntraktes. Methoden: Die Daten von 28 kontrastangehobenen MR-Urographien (5 normal; 23 pathologisch) wurden zur Erstellung einer virtuellen Ureterorenoskopie (VURS) mittels Schwellenwert-Bildsegmentierung nachverarbeitet. Als Grundlage fuer die Darstellung des Harntraktes

  10. Non-invasive determination of metabolite concentrations in human transplanted kidney in vivo by 31P MR spectroscopy

    International Nuclear Information System (INIS)

    Kugel, H.; Wittsack, H.J.; Wenzel, F.; Heindel, W.; Lackner, K.; Stippel, D.

    2000-01-01

    To investigate concentrations of phosphorus-containing metabolites in human transplanted kidney in vivo by quantitative 31 P MR spectroscopy (MRS) using surface coils and to compare the obtained values with previous data. Material and Methods: In 5 patients with well-functioning transplanted kidneys, 31 P spectra were obtained with the three-dimensional localization image-selected in vivo spectroscopy technique applying a protocol for quantitative spectroscopy using surface coils. Relaxation corrected signal intensities determined by time domain fitting were used to derive absolute molar concentrations for phosphate-containing metabolites. Results: Little or no phosphocreatine in all spectra verified the absence of muscle contamination, confirming proper volume localization. The mean concentrations in the transplanted kidneys were as follows: ATP 1.60±0.26 mmol/l, PDE 2.14±0.91 mmol/l, Pi 0.66±0.25 mmol/l, PME 2.32±0.50 mmol/l. These values are consistent with previously reported values determined by other techniques. Conclusion: The non-invasive determination of absolute metabolite concentrations in human kidney using MRS supplements the use of signal intensity ratios to detect pathologic changes in the energy metabolism of transplanted kidneys

  11. Prognostic impact of pre-transplantation computed tomography and 67gallium scanning in chemosensitive diffuse large B cell lymphoma patients undergoing hematopoietic stem-cell transplantation

    International Nuclear Information System (INIS)

    Escobar, Ignacio G.; Alonso, Pilar T.; Barrigon, Dolores C.; Perez-Simon, Jose A.; Mateos Manteca, Maria V.; San Miguel Izquierdo, Jesus F.

    2008-01-01

    In the present study, we evaluated computed tomography (CT) and 67 gallium scanning ( 67 Ga scan) pre-transplant as prognostic factors for overall survival (OS) and event-free survival (EFS) in patients with diffuse large B cell lymphoma, undergoing high-dose chemotherapy and stem-cell transplantation. Forty-two patients were included. Of these, 9 (21%) had both positive CT and 67 Ga scans, 17 (41%) negative results with both techniques, and 16 (38%) positive CT/negative 67 Ga scan. Whole-body planar imaging and single-photon emission computed tomography (SPECT) were performed 72 h after an intravenous administration of 67 Ga citrate measuring between 7 mCi and 10 mCi (259-370 MBq). Patients with positive CT/positive 67 Ga scan had a significantly worse EFS and OS at 5 years than those with negative 67 Ga scan regardless of whether it was associated with a positive or a negative CT scan (29% and 16% vs. 81% and 93% vs. 88% and 100%, respectively, P 67 Ga scan and those with positive CT/negative 67 Ga scan, with an EFS and OS at 5 years of 88% versus 81% and 100% versus 93%, respectively. In multivariate analysis, the presence of a pre-transplant positive CT/ 67 Ga scans adversely influenced both EFS and OS [HR 8, 95% confidence interval (CI) (1.4-38), P=0.03 and HR 2; 95% CI (1.3-8), P=0.02, respectively]. 67 Ga scan helps to identify, in the pre-transplant evaluation, two groups with a different outcome: one group of patients with positive CT and negative 67 Ga scans pre-transplant, who showed a favorable outcome with a low rate of relapse, and the other group of patients with both positive CT and 67 Ga scans pre-transplant, who showed a poor prognosis and did not benefit from autologous stem-cell transplantation. They should have been offered other therapeutic strategies. (author)

  12. Supplementary methods in breast cancer screening: ultrasonography and magnetic resonance tomography of the breast; Mammasonographie und Magnetresonanz-Mammographie als ergaenzende Methoden im Mammographiescreening

    Energy Technology Data Exchange (ETDEWEB)

    Delorme, S. [Deutsches Krebsforschungszentrum Heidelberg (Germany). Abt. fuer Onkologische Diagnostik und Therapie

    2001-04-01

    Ultrasonography and magnetic resonance (MR) tomography are helpful tools to evaluate unclear lesions found at screening mammography. Ultrasound is particularly useful to prove the presence of a cyst or to further examine unclear, asymmetrical densities. With MR mammography, carcinomas can be found even when X-ray mammography or ultrasonography are limited due to diffuse, benign, proliferative changes. Ultrasound guidance has greatly facilitated core needle biopsy for suspicious lesions. Additionally, approved devices for MR-guided biopsy are commercially available. As a primary screening tool, ultrasound or MR mammography may be used only in women who are positive for BRCA-1 or BRCA-2 mutations or who are otherwise at high risk for breast cancer. (orig.) [German] Sonographie und Magnetresonanz-Mammographie koennen zur Abklaerung unklarer Befunde eingesetzt werden, die im Rahmen des Mammographiescreenings auffallen. Die Mammosonographie eignet sich besonders zum Nachweis von Zysten und zur Abklaerung unklarer Dichte-Asymmetrien. Mit der Magnetresonanz-Mammographie koennen Karzinome auch dann nachgewiesen werden, wenn die Untersuchungsbedingungen fuer die Roentgenmammographie oder die Sonographie aufgrund einer Mastopathie unguenstig sind. Bei der differenzialdiagnostischen Abklaerung von Herdbefunden hat die Moeglichkeit der sonographischen Fuehrung einer Stanz- oder Vakuumbiopsie das Verfahren wesentlich vereinfacht. Fuer die MR-gesteuerte Biopsie sind inzwischen zugelassene Fuehrungshilfen kommerziell erhaeltlich. Als primaere Screeningmethode kommen sowohl die Sonographie als auch die Magnetresonanz-Mammographie nur fuer wenige Frauen in Frage, in der Regel bei nachgewiesenen BRCA-1- oder BRCA-2-Mutationen oder bei sonstiger Brustkrebsdisposition. (orig.)

  13. Valvular heart disease: assessment of valve morphology and quantification using MR

    Energy Technology Data Exchange (ETDEWEB)

    Schwitter, J. [Div. of Cardiology and Cardiovascular, MR Center, Univ. Hospital Zurich (Switzerland)

    2000-06-01

    For clinical evaluation and decision-making in patients with valvular heart disease, the diagnostic armamentarium expands steadily. This evolution makes it difficult to choose the most appropriate approach for a specific valvular lesion. It may also reflect our uncertainty of what are the findings that best predict clinical outcome of patients, e. g. after surgery. Accordingly, for each type of valvular lesion, some pathophysiological considerations are stated in order to derive the most important measures that would allow optimal guidance of patients. Based on these considerations the value of an MR study is discussed for each valvular lesion. Newest advances in MR technology allow for highly accurate measurements of regurgitant volumes and hence, MR may be the method of choice for a quantitative evaluation of regurgitant valves. For assessment of stenosis severity, measurement of transvalvular pressure gradient is an appropriate measure and MR may not confer benefits over echocardiography, provided the ultrasound window is adequate (and stroke volume is in the normal range). With respect to surgical treatment, valvular morphology is of pivotal importance, particularly for the mitral valve, and echocardiography still appears to be the first line method. Little data relate lesion severity and/or morphology to clinical outcome. Conversely, the extent of cardiac adaptation to pressure- and/or volume-overload, i. e. ventricular remodeling, is a strong predictor of outcome, and is therefore most important for final judgement of the patient. For assessment of left and right ventricular remodeling, echocardiography typically provides all the necessary information. However, in special cases with discrepant findings, with inadequate ultrasound window, or in the preoperative work-up, MR may provide important information regarding cardiac adaptation to valvular lesion. (orig.) [German] Das diagnostische Repertoire zur Evaluation von Klappenvitien ist in den letzten Jahren

  14. Value of different MR techniques in diagnosis of degenerative disorders of the hyaline cartilage - in vitro study on 50 joint specimens of the knee with 1.5 T; Vergleich von verschiedenen MRT-Techniken in der Diagnose von degenerativen Knorpelerkrankungen - in-vitro-Studie an 50 Gelenkpraeparaten des Knies bei 1,5 T

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, G. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Heinrichs, C. [Klinikum der Univ. Giessen (Germany). Inst. fuer Pathologie; Juergensen, I. [Klinikum der Univ. Giessen (Germany). Orthopaedische Klinik; Rominger, M. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Scheiter, A. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie; Rau, W.S. [Klinikum der Univ. Giessen (Germany). Abt. Diagnostische Radiologie

    1997-05-01

    Purpose: An experimental study was performed on joint specimens of the knee to assess the advantages and disadvantages of 14 generally available sequences in cartilage imaging. Methods: Each of the 50 surgically exposed cadaveric joints of the knee was examined by the following sequences: T{sub 1}, proton- and T{sub 2} weighted spin echo(SE) sequences, proton- and T{sub 2} weighted Turbo-SE, T{sub 1} weighted SE with fat suppression, MTC combined with T{sub 1}-weighted SE and T{sub 2} weighted FLASH-2 D, STIR, FISP-3 D, FLASH-3 D (with fat suppression), and MR arthrography. We assessed the image quality by a scale, signal to noise-ratio of cartilage and joint fluid, and the accuracy in detection of cartilage lesions. Pathology and arthroscopy were reference methods to MRI, and demonstrated grade 1-4 lesions on 186 of 300 joint facettes. Results: Advanced stages of cartilage lesions (65 grade 3 and 4 lesions) were detected by standard SE sequences in 67-94%. Application of volume techniques (FISP-3 D, FLASH-3 D), high definition matrix (512 pixel), MTC with FLASH-2 D and MR-arthrography improved the sensitivity up to 82-100%. Superficial lesions (65 grade 2 lesions) were demonstrated in 3-38%, and on MR arthrography in 45%. Structural changes (56 Grade 1 lesions) were recorded on MRI in only 10%. Conclusions: With regard to standard SE sequences, the detectability of cartilage lesions can be improved by techniques that use 512 matrices, selective cartilage imaging, and volume acquisition. (orig.) [Deutsch] Ziel: In einer experimentellen Studie an Gelenkpraeparaten des Knies wurden die Vor- und Nachteile von 14 allgemein verfuegbaren MRT-Sequenzen in der Knorpeldiagnostik dargestellt. Methode: 50 chirurgisch exstirpierte Kniegelenkpraeparate wurden nacheinander mit folgenden Techniken untersucht: Klassische Spin-Echo(SE)-Sequenz in T{sub 1}-, Protonen- und T{sub 2}-Wichtung, Turbo-SE in Protonen- und T{sub 2}-Wichtung, Fettsuppression mit T{sub 1}-gew. SE, MTC in

  15. MR spectroscopy in metabolic disorders of the brain; MR-Spektroskopie bei Stoffwechselerkrankungen des Gehirns

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, U. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2017-06-15

    Metabolic disorders of the brain often present a particular challenge for the neuroradiologist, since the disorders are rare, changes on conventional MR are often non-specific and there are numerous differential diagnoses for the white substance lesions. As a complementary method to conventional brain MRI, MR spectroscopy may help to reduce the scope of the differential diagnosis. Entities with specific MR spectroscopy patterns are Canavan disease, maple syrup urine disease, nonketotic hyperglycinemia and creatine deficiency. (orig.) [German] Die Diagnostik metabolischer Erkrankungen des Gehirns stellt eine besondere Herausforderung in der Neuroradiologie dar, da die Erkrankungen insgesamt selten, die bildmorphologischen Befunde haeufig unspezifisch sind und es eine Vielzahl von Differenzialdiagnosen fuer die Veraenderungen der weissen Substanz gibt. Als zusaetzliche Technik kann die MR-Spektroskopie bei Stoffwechselerkrankungen helfen, die Diagnose einzugrenzen. Krankheitsentitaeten, die spezifische Veraenderungen in der Spektroskopie aufweisen, sind der Morbus Canavan, die Ahornsirupkrankheit, die nichtketotische Hyperglyzinaemie und Kreatinmangelsyndrome. (orig.)

  16. Evaluation of renal vascular in living donors before transplantation using dynamic contrast enhanced MR angiography

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Zhong Xin; Dong Yuru; Dong Yue; Ma Yi; Wu Chunnan

    2010-01-01

    Objective: To explore whether dynamic contrast-enhanced MRA (DCE MRA) can provide an effective assessment of renal vascular in living donors before transplantation. Methods: Thirty five healthy living renal donor candidates were scanned on MR system before transplantation. After injection of Gd-DTPA 1 ml in vein, a test-bolus scan was used to get the time delay of Gd-DTPA reaching renal artery. Then, a 3D T 1 -weighted fast low-angle shot sequence (3D FLASH) was performed in the coronal plane. The 3D FLASH scan would repeat four times with an inter-phase of 10 seconds. Thus, the imaging of the renal arterial, venous and collecting systems were got. Two radiologists observed renal arteries and veins on original imaging and MIP reconstmcted imaging. The quality of MR angiography was evaluated on a five- point scale and the vascular anatomy or variations of the arterial and venous systems were recorded, using intraoperative findings as a standard of reference. Results: The quality for all MRA was good or very good for the most of living renal donors. Among 70 renals, several variations of vascular were found, including 5 left accessory artery, 9 right accessory artery, 3 left proximal arterial branch and 6 right proximal arterial branch. Among 70 renal veins, 1 right accessory veins and 2 left varicocele were observed. One small accessory artery of right kidney was missed with DCE MRA, but identified by operation. Conclusion: DCE MRA was noninvasive tool for evaluation of the renal vasculature and variations with high accuracy. It would be a good modality in preoperative evaluation of living renal donors. (authors)

  17. An experimental study of the diagnosing value to nude mice model of transplanted human gastric cancer with folate-receptor MR contrast agent

    International Nuclear Information System (INIS)

    Ding Jianhui; Zeng Mengsu; Zhou Kangrong; Shen Jizhang; Chen Caizhong; Zhong Gaoren; Xue Qiong; Gu Haiyan

    2005-01-01

    Objective: To evaluate the tumor targeting characteristic by observing signal varying of human gastric cancer transplanted nude mice (SGC-7901 ) using Folate-Receptor MR contrast agent. Methods: As a Folate-Receptor MR contrast agent, Gd-DTPA-Folate was obtained by conjugation of DTPA-Folate and GdCl 3 under specific conditions. Nude mice of subcutaneously transplanted human gastric cancer (SGC-7901) were used as animal models, 12 mice were divided into experimental group (n=6) and control group (n=6) randomly. Both were injected with Gd-DTPA-Folate and Gd-DTPA (contained same gadolinium) via abdominal cavity respectively. Tumor signal varying was observed by T 1 WI after injection of contrast agent immediately, 1, 2, 3, 4, 6, 12 and 24 h, and tumor signal changing of experimental group was compared with that of control group. CNR (contrast noise ratio) was regarded as evaluating mark. Results: Tumor signal intensity of experimental group was increased evidently between 1-2 hours after injecting Gd-DTPA-Folate. Comparison with pre-injection, there was a significant difference (evaluating mark is CNR: q 1 =5.80, q 2 =4.64; P 1 =0.64, q 2 =1.19, P>0.05). Conclusion: Gd-DTPA-Folate shows definite characteristic of tumor targeting effect to nude mice of subcutaneously transplanted human gastric cancer (SGC-7901). (authors)

  18. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    International Nuclear Information System (INIS)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders; Andersson, Anna; Biglarnia, Ali-Reza

    2012-01-01

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume

  19. Measurement of transplanted pancreatic volume using computed tomography: reliability by intra- and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Lundqvist, Eva; Segelsjoe, Monica; Magnusson, Anders [Uppsala Univ., Dept. of Radiology, Oncology and Radiation Science, Section of Radiology, Uppsala (Sweden)], E-mail: eva.lundqvist.8954@student.uu.se; Andersson, Anna; Biglarnia, Ali-Reza [Dept. of Surgical Sciences, Section of Transplantation Surgery, Uppsala Univ. Hospital, Uppsala (Sweden)

    2012-11-15

    Background Unlike other solid organ transplants, pancreas allografts can undergo a substantial decrease in baseline volume after transplantation. This phenomenon has not been well characterized, as there are insufficient data on reliable and reproducible volume assessments. We hypothesized that characterization of pancreatic volume by means of computed tomography (CT) could be a useful method for clinical follow-up in pancreas transplant patients. Purpose To evaluate the feasibility and reliability of pancreatic volume assessment using CT scan in transplanted patients. Material and Methods CT examinations were performed on 21 consecutive patients undergoing pancreas transplantation. Volume measurements were carried out by two observers tracing the pancreatic contours in all slices. The observers performed the measurements twice for each patient. Differences in volume measurement were used to evaluate intra- and inter-observer variability. Results The intra-observer variability for the pancreatic volume measurements of Observers 1 and 2 was found to be in almost perfect agreement, with an intraclass correlation coefficient (ICC) of 0.90 (0.77-0.96) and 0.99 (0.98-1.0), respectively. Regarding inter-observer validity, the ICCs for the first and second measurements were 0.90 (range, 0.77-0.96) and 0.95 (range, 0.85-0.98), respectively. Conclusion CT volumetry is a reliable and reproducible method for measurement of transplanted pancreatic volume.

  20. Loop myopexy with true muscle transplantation for very large angle heavy eye syndrome patient

    Directory of Open Access Journals (Sweden)

    Jitendra Jethani

    2015-01-01

    Full Text Available A 42-year-old man presenting with complaints of squint for last 20 years. His visual acuity was 20/400 in right eye (RE and 20/30 in left eye (LE with glasses. His refraction was RE -16.75/-2.5 D cycl 180 and LE was -14.5/-1.5 D cycl 180. His axial length was 31.23 mm In RE and 29.72 mm in LE. On examination we found he had RE large esotropia with hypotropia measuring 130 pd base out and 40 pd base up in RE. A computerized tomography scan revealed that the superior rectus (SR was shifted nasally, and lateral rectus (LR was shifted inferiorly. A RE medial rectus (MR recession and LR resection with muscle transplantation on the MR was done. A loop myopexy was done to correct the path of the LR and SR. The patient had only 18 pd eso and 20 pd hypo on follow-up after 3 months. Loop myopexy in conjunction with muscle transplantation is a safe and effective procedure for large angle esotropia associated with heavy eye syndrome.

  1. Optical Coherence Tomography in Kidney Transplantation

    Science.gov (United States)

    Andrews, Peter M.; Wierwille, Jeremiah; Chen, Yu

    End-stage renal disease (ESRD) is associated with both high mortality rates and an enormous economic burden [1]. The preferred treatment option for ESRD that can extend patients' lives and improve their quality of life is kidney transplantation. However, organ shortages continue to pose a major problem in kidney transplantation. Most kidneys for transplantation come from heart-beating cadavers. Although non-heart-beating cadavers represent a potentially large pool of donor kidneys, these kidneys are not often used due to the unknown extent of damage to the renal tubules (i.e., acute tubular necrosis or "ATN") induced by ischemia (i.e., lack of blood flow). Also, ischemic insult suffered by kidneys awaiting transplantation frequently causes ATN that leads to varying degrees of delayed graft function (DGF) after transplantation. Finally, ATN represents a significant risk for eventual graft and patient survival [2, 3] and can be difficult to discern from rejection. In present clinical practice, there is no reliable real-time test to determine the viability of donor kidneys and whether or not donor kidneys might exhibit ATN. Therefore, there is a critical need for an objective and reliable real-time test to predict ATN to use these organs safely and utilize the donor pool optimally. In this review, we provided preliminary data indicating that OCT can be used to predict the post-transplant function of kidneys used in transplantation.

  2. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI; Indirekte MR-Phlebografie: Kontrastmittelprotokolle, Nachverarbeitung und Kombination mit Lungenemboliediagnostik in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Kluge, A.; Bachmann, G. [Diagnostische Radiologie, Kerckhoff-Klinik, Bad Nauheim (Germany); Rominger, M. [Diagnostische Radiologie, Phillips-Univ. Marburg (Germany); Schoenburg, M. [Herzchirurgie, Kerckhoff-Klinik, Bad Nauheim (Germany)

    2004-07-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [German] Ziel: Integration der MR-Phlebografie in ein umfassendes Konzept der MRT-Diagnostik bei Verdacht auf Lungenembolie (LE). Untersuchung des Einflusses von Kontrastmittelmenge, -bolusform und Verzoegerungszeit sowie der Nachverarbeitung auf die diagnostische Qualitaet von MR-Phlebografien. Material und Methode: Bei 48 konsekutiven stationaeren Patienten mit Verdacht auf Beinvenenthrombose (TVT

  3. Xenon-computed tomography of kidney transplants

    International Nuclear Information System (INIS)

    Mutze, S.; Reichmuth, B.; Suess, C.; Lippert, J.; Ewert, R.

    1994-01-01

    Xenon-CT is an established method for determining cerebral perfusion, while applications in other organs are rare. We evaluated the diagnostic potential of measuring the regional Renal Blood Flow (rRBF) in 10 patients with transplanted kidneys by xenon-CT. We found significant differences in the rRBF between the renal medulla and the cortex. There were no differences between normal renal transplants and transplants with chronic rejection. (orig.) [de

  4. MR diffusion tensor imaging in the evaluation of neural progenitor cells transplantation to acute injured canine spinal cord

    International Nuclear Information System (INIS)

    Wang Xiaoying; Tan Ke; Ni Shilei; Bao Shengde; Jiang Xuexiang

    2006-01-01

    Objective: To observe the effect of transplantation of telomerase immortalized human neural progenitor cells to acute injured canine spinal cord by using MR diffusion tensor imaging (DTI). Methods: Telomerase immortalized human neural progenitor cells with expression of green fluorescent protein were prepared for transplantation. Eight adult canines with left spinal cord hemisection at the level of T13 were examined by MR diffusion tensor imaging four times sequentially: prior to injury, one week after injury, one week after transplantation (two weeks after injury), and four weeks after transplantation. Results: The ADC values of the injured spinal cord were (1.00 ± 0.15) x 10 -3 mm 2 /s, (1.65 ± 0.45) x 10 -3 mm 2 /s, (1.44 ± 0.48) xl0 -3 mm 2 /s, and (1.43 ± 0.26) x 10 -3 mm 2 /s, respectively. There was statistically significant difference between the data obtained at different times (F= 6.038, P=0.005). The FA values of the injured spinal cord were 0.59±0.11, 0.30±0.17, 0.36±0.25, and 0.34±0.11, respectively. There was also statistically significant difference between the data obtained at different times (F=5.221, P=0.009). The ADC values of the intact spinal cord were (1.01±0.17) x 10 -3 mm 2 /s, (1.32±0.06) x 10 -3 mm 2 /s, (1.10±0.24) x 10 -3 mm 2 /s, and (1.14±0.22) x 10 -3 mm 2 /s, respectively. There was no statistically significant difference between the data obtained at different times (F=1.303, P=0.306). The FA values of the intact spinal cord were 0.60 ± 0.09, 0.38 ± 0.25, 0.46 ± 0.15, and 0.50 ± 0.21, respectively. There was also no statistically significant difference between the data obtained at different times (F=2.797, P=0.072). Conclusion: DTI can provide useful information for spinal cord injury and regeneration in experimental spinal cord injury. (authors)

  5. MR appearance of hypothalamic hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, F.J.; Leibrock, L.G.; Huseman, C.A.; Makos, M.M.

    1988-02-01

    Hypothalamic hamartoma is the most common detectable cerebral lesion causing precocious puberty. Two histologically confirmed cases were studied by computerized tomography (CT) and magnetic resonance (MR) imaging. T2 weighted, sagittal MR images were superior to CT in delineating the tumor from surrounding grey matter. The lesion was isointense to grey matter on T1 weighted images allowing exclusion of other hypothalamic tumors. MR will undoubtedly become the imaging modality of choice in the detection of hypothalamic hamartoma.

  6. MR-angiography in vasculitis and benign angiopathy of the central nervous system; MR-Angiographie in der Diagnostik von Vaskulitiden und benignen Angiopathien des Zentralnervensystems

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, A.; Hirsch, W.; Jassoy, A.; Behrmann, C.; Spielmann, R.P. [Klinik fuer Diagnostische Radiologie, Martin-Luther-Univ. Halle-Wittenberg (Germany); Kornhuber, M. [Klinik fuer Neurologie, Martin-Luther-Univ. Halle-Wittenberg (Germany); Keysser, G. [Klinik fuer Innere Medizin I, Martin-Luther-Univ. Halle-Wittenberg (Germany)

    2001-06-01

    To evaluate TOF 3D magnetic resonance angiography (MRA) of the intracranial arteries in patients with vasculitis or vasculitis-like benign angiopathy of the central nervous system (CNS). Method: The results of MRA in 20 patients with clinically and radiographically proven vasculitis (17/20) or vasculitis-like benign angiopathy (3/20) of the CNS were retrospectively analysed. Patients with hyperintense lesions of more than 3 mm on T{sub 2}-weighted MRI images were included in this trial. An inflammatory, embolic, neurodegenerative or metastatic origin of these lesions was excluded by extensive clinical studies. For the MR-examination a TOF 3D FISP sequence was used on a 1.5 T imager. Results: MRA showed characteristic changes for vasculitis or angiopathy in 15 of 20 patients (75%). Conclusions: In patients suspected of having a vasculitis or vasculitis-like angiopathy, MRA is recommended as a non-invasive modality. If the results of MRI and extensive clinical studies are carefully correlated, MRA may substitute conventional angiography in cases with typical vascular changes. (orig.) [German] Ziel der Studie war es, den Wert der TOF 3D Magnetresonanzangiographie (MRA) bei Patienten mit Vaskulitis oder vaskulitisaehnlichen, benignen Angiopathien des Zentralnervensystems (ZNS) zu erfassen. Methoden: Die MRA-Aufnahmen von 20 Patienten mit klinisch und bildgebend nachgewiesener Vaskulitis (17/20) oder vaskulitisaehnlicher, benigner Angiopathie (3/20) des ZNS wurden retrospektiv ausgewertet. Eingeschlossen wurden Patienten mit Laesionen des Hirnparenchymsgroessen 3 mm in den T{sub 2}-gewichteten Sequenzen der MRT, wobei diese Veraenderungen aufgrund umfangreicher klinischer Untersuchungen nicht auf das Vorliegen neurodegenerativer, anderweitig entzuendlicher, metastatischer oder embolischer Ursachen zurueckzufuehren waren. Fuer die MRA wurde eine TOF 3D FISP-Sequenz auf einem 1,5T MR-Geraet verwendet. Ergebnisse: MR-angiographisch wurden bei 15/20 Patienten (75

  7. Computed tomography after liver transplantation

    International Nuclear Information System (INIS)

    Dupuy, D.E.; Costello, P.

    1992-01-01

    Orthotopic liver transplantation is commonly performed at many institutions around the world. The care of these critically ill patients has heavily relied upon cross-sectional imaging, specifically CT. CT is of enormous benefit in the postoperative management of the various complications which is common in this group of patients. This article reviews the role of CT and its respective strengths and weaknesses, in the adult liver transplant recipient. (orig.) [de

  8. Craniofacial duplication (diprosopus): CT, MR imaging, and MR angiography findings case report.

    Science.gov (United States)

    Hähnel, Stefan; Schramm, Peter; Hassfeld, Stefan; Steiner, Hans H; Seitz, Angelika

    2003-01-01

    Diprosopus is one of the rarest malformations in humans. In addition to the facial structures, the cerebral frontal lobes were duplicated in this case. Three pairs of anterior cerebral arteries were detected, and the rostral parts of the superior sagittal sinus were duplicated. Computed tomography, magnetic resonance (MR) imaging, and MR angiography allowed study of the degree of duplicative changes in diprosopus, especially for planning cosmetic correction. Copyright RSNA, 2002

  9. Clinical use of MR imaging-guided interventions; Klinischer Einsatz der interventionellen MRT (iMRT)

    Energy Technology Data Exchange (ETDEWEB)

    Kahn, T.; Schulz, T.; Moche, M.; Prothmann, S.; Schneider, J.P. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany)

    2003-07-01

    The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures. (orig.) [German] Die Integration diagnostischer und therapeutischer Massnahmen durch die MRT basiert auf der Kombination von exzellenter morphologischer und funktioneller Bildgebung. Das Spektrum MR-gefuehrter Eingriffe reicht von Biopsien, thermischen Therapieverfahren, vaskulaeren Applikationen bis hin zum intraoperativen Einsatz der MRT. Auf allen Gebieten konnten von verschiedenen Arbeitsgruppen ueberzeugende Ergebnisse sowohl im Bereich der Grundlagenentwicklung als auch bei klinischen Anwendungen vorgelegt werden. Es ist davon auszugehen, dass die interventionelle MRT einen hohen Stellenwert im Bereich der interventionellen Radiologie, der minimal-invasiven Therapie und der Ueberwachung von operativen Eingriffen erlangen wird. (orig.)

  10. Value of MR-guided localization and biopsy in breast lesions; Stellenwert der MR-gestuetzten Lokalisation und Biopsie von Brustlaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Grabbe, E.; Knollmann, F. [Abt. Diagnostische Radiologie, Georg-August-Univ. Goettingen (Germany)

    2006-05-15

    Contrast-enhanced dynamic MR mammography can provide important additional diagnostic information when performed for certain indications. When suspicious lesions are identified on MR mammography and cannot be reproduced using other imaging modalities, a decision must be made as to its management, i.e. further diagnostic work-up. One possibility is the short-term follow-up of such findings, resulting in higher costs and a possible delay in the start of treatment of a malignant lesion. An alternative to a follow-up is an MR-guide intervention. MR-compatible equipment has been developed for this purpose. This includes equipment specialized for percutaneous biopsy and preoperative localization. The following is an overview of the diagnostic value of MR-guided biopsy and preoperative localization including the relevant literature. (orig.)

  11. MR imaging features of craniodiaphyseal dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Marden, Franklin A. [Mallinckrodt Institute of Radiology, Washington University Medical Center, 510 South Kingshighway Blvd., MO 63110, St. Louis (United States); Department of Radiology, St. Louis Children' s Hospital, Children' s Place, MO 63110, St. Louis (United States); Wippold, Franz J. [Mallinckrodt Institute of Radiology, Washington University Medical Center, 510 South Kingshighway Blvd., MO 63110, St. Louis (United States); Department of Radiology, St. Louis Children' s Hospital, Children' s Place, MO 63110, St. Louis (United States); Department of Radiology/Nuclear Medicine, F. Edward Hebert School of Medicine, Uniformed Services University of the Health Sciences, MD 20814, Bethesda (United States)

    2004-02-01

    We report the magnetic resonance (MR) imaging findings in a 4-year-old girl with characteristic radiographic and computed tomography (CT) features of craniodiaphyseal dysplasia. MR imaging exquisitely depicted cranial nerve compression, small foramen magnum, hydrocephalus, and other intracranial complications of this syndrome. A syrinx of the cervical spinal cord was demonstrated. We suggest that MR imaging become a routine component of the evaluation of these patients. (orig.)

  12. MR imaging characteristics of osteoradionecrosis of the pelvis after radiation therapy on gynecological tumors; Pelvine Osteoradionekrosen: Magnetresonanztomographische Charakteristika

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, J.; Abolmaali, N.D.; Jacobi, V.; Vogl, T.J. [Institut fuer Diagnostische u. Interventionelle Radiologie, Klinikum der J. W. Goethe-Universitaet, Frankfurt (Germany); Hoeller, U. [Staedtisches Krankenhaus Neukoelln, Berlin (Germany). Abt. Strahlentherapie; Schiemann, M.; Obert, K. [Klinikum der J. W. Goethe-Universitaet, Frankfurt (Germany). Klinik fuer Strahlentherapie und Onkologie

    2002-01-01

    Purpose: To describe MR imaging characteristics of osteoradionecrosis (ORN) of the pelvis as a result of radiation therapy (RT) on gynecological tumors. Material and Methods: Radiography, computed tomography (CT) and magnetic resonance imaging (MRI) were performed on 9 women (mean age 67.5 years) with gynecological tumors to identify ORN. T{sub 1}- and T{sub 2}-weighted sequences and contrast-enhanced t{sub 1}-weighted sequences with and without fat saturation were used. The patients began developing pain after the completion of RT indicating a possible ORN a which time MRI was performed. MR images were correlated with the results of clinical examinations. Results: Depending on the time elapsed after RT, ORN presented with different signal intensities. The acquired images suggested that signal changes in T{sub 2}-weighted images as well as the different enhancement behaviour of ORN could be dependent on the time elapsed after RT. Visualisation of the affected regions was best achieved with fat-saturated T{sub 1}-weighted sequences. CT showed increased density in the affected regions corresponding to osteosclerosis. In all cases the sacroiliac joint was affected, some times bilateraly. Conclusion: MRI is helpful in detecting and characterizing ORN. Changes in signal intensity, based on histopathological tissue changes could make a chronological classification possible. (orig.) [German] Zielsetzung: Evaluation MR-tomographischer Charakteristika pelviner Osteoradionekrosen (ORN) bei Patientinnen nach Strahlentherapie gynaekologischer Tumoren. Material und Methode: 9 Patientinnen (mittleres Alter: 67,5 Jahre) mit gynaekologischen Tumoren und gesicherten ORN wurden mit der Magnetresonanztomographie (MRT) untersucht. Die MRT wurde beim Auftreten von Beschwerden nach unterschiedlichen Zeiten nach Bestrahlungsabschluss durchgefuehrt und mit den Ergebnissen der klinischen Diagnostik korreliert. Ergebnisse: ORN kamen fuer MR in Abhaengigkeit vom Abstand zum Bestrahlungsende

  13. Gd-BOPTA-enhanced excretory MR urography without administration of diuretics; Gd-BOPTA-gestuetzte MR-Ausscheidungsurographie ohne Diuretikagabe

    Energy Technology Data Exchange (ETDEWEB)

    Allkemper, T.; Tombach, B.; Heindel, W. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie

    2001-02-01

    Purpose: To evaluate the feasibility and clinical utility of Gd-BOPTA enhanced excretory magnetic resonance urography without additional administration of diuretics in correlation with conventional urography. Method: 15 preoperative patients with pelvic tumors were examined at 1.5 T using a breath-hold high-resolution 3D-FLASH sequence during first-pass as well as 5, 10, 15 minutes after iv. injection of 0.05 mmol/kg BW Gd-BOPTA (MultiHance {sup trademark}) without administration of diuretics. Post-processed coronal and multiplanar MIP reconstructions were compared to conventional excretory urography with regard to morphologic accuracy, anatomic variability, filling defects, cause and level of obstruction or compression, tumor visibility, and time-effectiveness by two independent radiologists. Results: Visualization of the urinary tract by MRU was comparable to conventional excretory urography in 14 of 15 cases. Caliceal fornices were better delineated on conventional urographies, whereas MRU was considered superior in the assessment of the inferior ureter sections, the urinary bladder and obstructive tumors, whose extents could be clearly marked out. Examination times of both techniques were comparable. Conclusion: These first results show that non-diuretic Gd-BOPTA enhanced MRU is comparable to conventional excretory urography for the preoperative diagnosis of pelvic tumors. Further improvements of this technique seem possible by optimization of examination intervals and injection doses. (orig.) [German] Ziel: Abschaetzung der Durchfuehrbarkeit und des klinischen Nutzens der Gd-BOPTA-gestuetzten MR-Ausscheidungsurographie (MRU) ohne zusaetzliche Diuretikagabe im Vergleich zur konventionellen Ausscheidungsurographie. Methoden: 15 Patienten mit Beckentumoren wurden praeoperativ an einem 1.5 T-Ganzkoerpersystem mit Hilfe einer atemgehaltenen, hochaufloesenden 3D-FLASH-Sequenz unmittelbar nach intra-venoeser Applikation von 0,05 mmol/kg KG Gd-BOPTA (MultiHance {sup

  14. Single-Lung Transplant Results in Position Dependent Changes in Regional Ventilation: An Observational Case Series Using Electrical Impedance Tomography

    Directory of Open Access Journals (Sweden)

    Kollengode Ramanathan

    2016-01-01

    Full Text Available Background. Lung transplantation is the optimal treatment for end stage lung disease. Donor shortage necessitates single-lung transplants (SLT, yet minimal data exists regarding regional ventilation in diseased versus transplanted lung measured by Electrical Impedance Tomography (EIT. Method. We aimed to determine regional ventilation in six SLT outpatients using EIT. We assessed end expiratory volume and tidal volumes. End expiratory lung impedance (EELI and Global Tidal Variation of Impedance were assessed in supine, right lateral, left lateral, sitting, and standing positions in transplanted and diseased lungs. A mixed model with random intercept per subject was used for statistical analysis. Results. EELI was significantly altered between diseased and transplanted lungs whilst lying on right and left side. One patient demonstrated pendelluft between lungs and was therefore excluded for further comparison of tidal variation. Tidal variation was significantly higher in the transplanted lung for the remaining five patients in all positions, except when lying on the right side. Conclusion. Ventilation to transplanted lung is better than diseased lung, especially in lateral positions. Positioning in patients with active unilateral lung pathologies will be implicated. This is the first study demonstrating changes in regional ventilation, associated with changes of position between transplanted and diseased lung.

  15. Detection of biliary and vascular anatomy in living liver donors: Value of gadobenate dimeglumine enhanced MR and MDCT angiography

    International Nuclear Information System (INIS)

    Artioli, Diana; Tagliabue, Marianna; Aseni, Paolo; Sironi, Sandro; Vanzulli, Angelo

    2010-01-01

    Objective: To evaluate the performance of magnetic resonance (MR) and multidetector computed tomography (MDCT) in the assessment of living donor's vascular and biliary anatomy, having surgical findings as reference standard. Methods: Thirty-two living liver donors underwent MR cholangiography (1.5-T; standard cholangiography pulse sequences and delayed acquisitions after administration of biliary contrast agent) for biliary anatomy evaluation. MDCT (16-row multidetector scanner, multiphase protocol, 3 mm slice thickness) was also performed in all cases for the assessment of vascular anatomy before transplantation. Hepatic veins (<4 mm in diameter) were not considered. MR and MDCT images interpretation was performed by two reviewers by consensus, based on source axial images, multiplanar reformats, and three-dimensional (3D) postprocessing images. Surgical intraoperative findings were used as standard of reference. Results: At surgery, 17 biliary anomalies, 3 portal anomalies, 32 venous and 8 arterial variants were found in the 32 patients. MR correctly identified 15/17 biliary anomalies, with a sensitivity of 88% and a specificity of 93%. MDCT correctly identified 8/8 arterial, 3/3 portal and 29/32 venous variants, with a sensitivity of 100% and 91%, respectively, and a specificity of 100%. Conclusions: MR and MDCT proved to be efficient in evaluating living liver donor's biliary and vascular anatomy.

  16. Detection of biliary and vascular anatomy in living liver donors: Value of gadobenate dimeglumine enhanced MR and MDCT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Artioli, Diana, E-mail: diansadiana@gmail.com [Ospedale Niguarda Ca' Granda, Piazza Ospedale Maggiore 3, 20162 Milano (Italy); Tagliabue, Marianna; Aseni, Paolo; Sironi, Sandro; Vanzulli, Angelo [Ospedale Niguarda Ca' Granda, Piazza Ospedale Maggiore 3, 20162 Milano (Italy)

    2010-11-15

    Objective: To evaluate the performance of magnetic resonance (MR) and multidetector computed tomography (MDCT) in the assessment of living donor's vascular and biliary anatomy, having surgical findings as reference standard. Methods: Thirty-two living liver donors underwent MR cholangiography (1.5-T; standard cholangiography pulse sequences and delayed acquisitions after administration of biliary contrast agent) for biliary anatomy evaluation. MDCT (16-row multidetector scanner, multiphase protocol, 3 mm slice thickness) was also performed in all cases for the assessment of vascular anatomy before transplantation. Hepatic veins (<4 mm in diameter) were not considered. MR and MDCT images interpretation was performed by two reviewers by consensus, based on source axial images, multiplanar reformats, and three-dimensional (3D) postprocessing images. Surgical intraoperative findings were used as standard of reference. Results: At surgery, 17 biliary anomalies, 3 portal anomalies, 32 venous and 8 arterial variants were found in the 32 patients. MR correctly identified 15/17 biliary anomalies, with a sensitivity of 88% and a specificity of 93%. MDCT correctly identified 8/8 arterial, 3/3 portal and 29/32 venous variants, with a sensitivity of 100% and 91%, respectively, and a specificity of 100%. Conclusions: MR and MDCT proved to be efficient in evaluating living liver donor's biliary and vascular anatomy.

  17. Postoperative MR arthography of the shoulder joint; MR-Arthographie des Schultergelenks im postoperativen Patientenkollektiv

    Energy Technology Data Exchange (ETDEWEB)

    Rand, T. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria); Trattnig, S. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria); Breitenseher, M. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria); Freilinger, W. [Orthopaedisches Krankenhaus Speising (Austria); Cochole, M. [Orthopaedische Abt., Allgemein Oeffentliches Krankenhaus Amstetten (Austria); Imhof, H. [Einrichtung fuer Magnetresonanz, Ludwig Boltzmann-Inst. fuer Radiologische Tumordiagnostik, Univ. Wien (Austria)

    1996-12-01

    Indications of MR arthrography were analyzed in this prospective study. The aim was to evaluate possible advantages over conventional MRI, establish diagnostic criteria and to analyze its meaning further for the therapeutic management of postoperative patients. MR arthrography was performed in eight patients who had undergone surgical repair of rotator cuff lesions (modified Neer acromioplasty) and in six patients who had undergone arthroscopic therapy of recurrent unidirectional dislocation of the shoulder by combined arthroscopic intra- and extracapsular repair. MR investigations were performed before and after application of a contrast solution (2 mmol Gd-DTPA). All patients suffered from chronic postoperative pain. In patients with rotator cuff lesions, a partial tear could be verified in one patient and excluded in all others. In patients after arthroscopic therapy by combined intra- and extracapsular repair, a radiologically patulous-appearing capsule correlated with clinically recurrent dislocations. In all other patients diagnostic criteria, such as distribution of the intra-articular contrast solution, proliferation of scar tissue, nodular appearance of the glenohumeral ligaments and capsule thickness, correlated with a regular postoperative status. MR arthrography of the shoulder represents a promising method in the evaluation of the postoperative shoulder. It might further improve the evaluation of reactive capsule alterations, scar tissue proliferation, and the labroligamentous complex, as well as the ability to differentiate partial and complete rerupture from degenerative changes of the rotator cuff. (orig.) [Deutsch] In einer prospektiven Studie sollten die Einsatzmoeglichkeiten der MR-Arthrographie am operierten Schultergelenk erfasst werden. Ziel der Studie war einerseits eine gegenueber der konventionellen MR-Untersuchung verbesserten Diagnosestellung und andererseits die Erstellung von fuer die Rezidivdiagnostik relevanten Diagnosekriterien

  18. Value of new MR techniques in MR-PET

    International Nuclear Information System (INIS)

    Attenberger, U.I.; Schoenberg, S.O.; Quick, H.H.; Guimaraes, A.; Catalano, O.; Morelli, J.N.

    2013-01-01

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [de

  19. Postictal MR-changes. A rare and important differential diagnosis; Postiktale MR-Veraenderungen. Eine seltene und wichtige Differenzialdiagnose

    Energy Technology Data Exchange (ETDEWEB)

    Hattingen, E.; Raab, P.; Lanfermann, H.; Zanella, F.E.; Weidauer, S. [Johann-Wolfgang-Goethe-Universitaet Frankfurt/Main, Institut fuer Neuroradiologie, Frankfurt (Germany)

    2008-11-15

    Postictal MR findings are analyzed in the context of MR morphological differential diagnoses. Postictal MRI was performed in 11 patients. The patterns of MR changes and their differential diagnoses were analyzed. Focal accentuation of signal increase in the cortex was found on T2-weighted images in 90% of these cases, pial enhancement in 70% and signal changes of the pulvinar/thalamus in 40%. The most common differential diagnoses were encephalitis, and in tumor patients carcinomatous involvement of the meninges. Postictal MR changes vary widely and are difficult to differentiate from illnesses such as encephalitis and carcinomatosis involving the meninges. Nevertheless, knowledge of the typical pattern of postictal MR findings and the clinical course may help to avoid mistaken diagnoses. (orig.) [German] Postiktale MR-Veraenderungen werden im Kontext ihrer Differenzialdiagnosen analysiert. Elf Patienten wurden postiktal im MRT untersucht. Ausgewertet wurden die MR-tomographischen Befundmuster und ihre Differenzialdiagnosen. Bei 90% der Patienten fanden sich fokale kortikal betonte Signalsteigerungen in der T2-Wichtung, bei 90% Diffusionseinschraenkungen, bei 70% piale Anreicherungen und bei 40% Signalalterationen des Pulvinars/Thalamus. Haeufigste Differenzialdiagnosen waren die Enzephalitis und bei entsprechender Tumoranamnese die Meningeosis carcinomatosa. Postiktale MR-Veraenderungen sind vielgestaltig und nicht immer leicht von Erkrankungen wie insbesondere der Enzephalitis oder der Meningeosis carcinomatosa zu unterscheiden. Dennoch helfen die Kenntnis typischer postiktaler Befallsmuster und der klinische Verlauf, Fehldiagnosen zu vermeiden. (orig.)

  20. Ultrasound findings in dual kidney transplantation.

    Science.gov (United States)

    Damasio, M B; Cittadini, G; Rolla, D; Massarino, F; Stagnaro, N; Gherzi, M; Paoletti, E; Derchi, L E

    2013-02-01

    This study was done to analyse colour Doppler ultrasound (CDUS) findings in patients with dual kidney transplantation (DKT) and to compare renal volume and resistive index (RI) values between DKT and single kidney transplantation (SKT). We reviewed the clinical and imaging findings [30 CDUS, five magnetic resonance (MR) and one computed tomography (CT) examination] in 30 patients with DKT (23 men and seven women; median age 65 years; range 55-82). Three patients had clinical signs of graft malfunction. Renal volumes and RI were compared with those of 14 SKT patients and comparable levels of renal function. Three patients had graft dysfunction: one had chronic rejection and two had pathologies involving one kidney only (one encrusted pyeloureteritis of a left graft and one occluded main artery of a left graft). Asymptomatic unilateral pathologies were seen in six cases. In asymptomatic DKT patients, no significant differences in length, volume, cortical echogenicity and RI between the two kidneys were observed; DKTs were smaller (median volume 116.7 vs. 171.6 cc) and had higher RIs (0.76 vs. 0.68) (pDKT, allowing detection of clinically unsuspected unilateral diseases. At comparable levels of renal function, DKT patients had higher RI and lower volumes than SKT patients.

  1. MR-myelography in patients with spinal canal stenosis; MR-Myelographie bei Spinalkanalstenosen

    Energy Technology Data Exchange (ETDEWEB)

    Freund, M.; Hutzelmann, A.; Steffens, J.C.; Heller, M. [Klinik fuer Radiologische Diagnostik, Christian-Albrechts-Universitaet zu Kiel (Germany); Buhl, R. [Klinik fuer Neurochirurgie, Christian-Albrechts-Universitaet zu Kiel (Germany)

    1997-11-01

    Purpose: The purpose of this prospective study was to evaluate the clinical value of 3D-MR-myelography (3D-MRM) in comparison to myelography and intra-operative findings. Material and Methods: 25 patients with suspected lumbar spinal canal stenosis were studied via myelography and 3D-MRM (volume-data set, 3D-FISP sequenz, T{sub R} 73 ms, T{sub E} 21 ms, flipangle 7 , sagittal slices) besides the routinely acquired sagittal and axial T{sub 1}- and T{sub 2}-weighted images. Diagnoses were made by two radiologists and one neurosurgeon without knowing the clinical history and symptoms, in two separate sessions. Results were compared to intraoperative findings. Results: 3D-MRM has the same diagnostic sensitivity (25/25=100%) as conventional X-ray myelography (25/25=100%) compared to intraoperative findings, but is not invasive and shows more diagnostic details than myelography. Especially in cases of high-grade spinal canal stenosis there is often a lack of intrathecal contrast medium distally of the stenosis. (orig./AJ) [Deutsch] Ziel: Bewertung der 3D-MR-Myelographie (3D-MRM) in der Diagnostik lumbaler Spinalkanalstenosen im Vergleich zu Myelographie und Korrelation mit intraoperativem Befund. Material und Methode: In einer fortlaufenden, prospektiven Studie wurden 25 Patienten mit den Symptomen einer lumbalen Spinalkanalstenose kernspintomographisch untersucht. Neben den ueblichen sagittalen und axialen T{sub 1}- und T{sub 2}-gewichteten Aufnahmen wurde ein Volumendatensatz mit einer 3D-FISP Sequenz (T{sub R} 73 ms, T{sub E} 21 ms, Flipwinkel 7 ) akquisiert. Die Nachverarbeitung erfolgte mittels Maximum Intensitaets-Projektion (MIP): 18 Projektionen von 0 -180 . Die 3D-MRM wurde der Myelographie gegenuebergestellt, beide Untersuchungen wurden getrennt von drei Untersuchern blind ausgewertet. Ergebnisse: Sowohl die 3D-MRM als auch die der Myelographie zeigten bei Patienten mit lumbaler Spinalkanalstenose in Korrelation zum intraoperativen Befund eine Uebereinstimmung

  2. MR tomography in myocardial ischaemia: present state of the art

    International Nuclear Information System (INIS)

    Szolar, D.H.; Saeed, M.; Higgins, C.B.

    1996-01-01

    Recent developments in MR imaging have opened up new avenues in the investigation of ischaemic heart disease. Conventional unenhanced spin-echo sequences have been used to detect and quantify myocardial infarction. Along with the technical advances aimed at reducing motion artifacts and imaging time, the advent of contrast media for MR imaging has further strengthened its diagnostic capacities. The applications of MR contrast media are increasing, and they are becoming more specific, to enable differentiation of occlusive and reperfused myocardial infarctions and to discriminate between reversible and irreversible myocardial injury. Previous studies have also indicated that dual administration of both relaxivity-based and susceptibility-based contrast media can be used to determine whether viable myocardium is present in the reperfused ischaemic area. Magnetic susceptibility MR contrast media have the potential to demonstrate a region of the ischaemically injured myocardium in which myocardial necrosis is present. A cornestone in the MR assessment of ischaemic heart disease has been achieved with the advent of fast MR imaging techniques. Ultrafast gradient-recalled-echo sequences or echoplanar imaging allow to monitor the first passage of the contrast medium through the heart. With the aid of MR contrast media, these techniques may be useful in estimating regional myocardial perfusion and blood volume. Experimental and clinical perfusion studies indicate that perfusion-sensitive MR imaging, particularly in concert with coronary vasodilators, can detect compromised myocardium. Combining myocardial perfusion imaging with the anatomic and functional information provided by other MR imaging techniques such as cine and velocity-encoded sequences could make MR imaging a comprehensive noninvasive diagnostic tool for the assessment of ischaemic heart disease. (orig.) [de

  3. MR arthrography of the shoulder: possible indications for clinical use; Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes

    Energy Technology Data Exchange (ETDEWEB)

    Kreitner, K.F. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Grebe, P. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Kersjes, W. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik fuer Unfallchirurgie; Kirschner, P. [Elisabeth-Hospital, Mainz (Germany). Abt. fuer Unfall- und Wiederherstellungschirurgie St. Vincenz; Schild, H.H. [Mainz Univ. (Germany). Klinik mit Poliklinik fuer Radiologie

    1994-02-01

    In a prospective study possible indications for MR arthrography of the shoulder were evaluated. 37 patients were examined before and after intraarticular administration of a 2-mmolar solution of Gd-DTPA. MR arthrography was performed if there was no joint effusion and/or an uncertain finding concerning the rotator cuff or the capsulolabral complex on plain MR images. MR arthrography leads to a better demonstration of labrum pathology in 11/22 patients and to a superior delineation of the capsuloligamentous apparatus in 20/22 cases. In 9/15 patients with impingement lesions MR arthrography allowed a differentiation of severe tendinitis from partial and small full-thickness tears of the rotator cuff. MR arthrography of the shoulder joint enhances the accuracy of MR in case of an uncertain finding on plain MR images. (orig.) [Deutsch] In einer prospektiven Studie sollten Einsatzmoeglichkeiten der MR-Arthrographie bei Erkrankungen des Schultergelenkes herausgearbeitet werden. 37 Patienten wurden sowohl nativ als auch nach intraartikulaerer Gabe einer 2mmolaren Gd-DTPA-Loesung untersucht. Voraussetzungen fuer die KM-Gabe waren ein fehlender Gelenkerguss und/oder ein unklarer Befund des Labrum-Kapsel-Komplexes oder der Rotatorenmanschette in der Nativuntersuchung. Durch die MR-Arthrographie wurde bei 11/22 Patienten eine verbesserte Darstellung der Labrumpathologie erzielt; in 20/22 Faellen ergabe sich eine zuverlaessige Beurteilung der Gelenkkapsel. Bei 9/15 Patienten mit Erkrankungen der Rotatorenmanschette konnten Tendinitiden von partiellen und kleinen kompletten Rotatorenmanschettenrupturen sicher differenziert werden. Die MR-Arthrographie des Schultergelenkes fuehrt bei nicht eindeutigen Befunden in der Nativuntersuchung zu einer verbesserten Treffsicherheit der MR-Diagnostik. (orig.)

  4. Risks and safety aspects related to PET/MR examinations

    International Nuclear Information System (INIS)

    Brix, Gunnar; Nekolla, Elke A.; Nosske, Dietmar; Griebel, Juergen

    2009-01-01

    The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety standards do not take into account synergistic effects of ionizing radiation and magnetic and electromagnetic fields. In the light of the developing PET/MR technology, there is an urgent need to investigate this aspect in more detail for exposure levels that will occur at PET/MR systems. (orig.)

  5. MR-guided percutaneous cryotherapy of liver metastases; MR-gesteuerte perkutane Kryotherapie von Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Haage, P.; Tacke, J. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    2001-01-01

    The prognosis for patients with liver metastases depends on the therapeutic options regarding the treatment of the primary tumor, co-existing extrahepatic metastases and the extent and treatment possibilities of the hepatic metastases themselves. Numerous curative or palliative oncological therapeutic concepts have been introduced in case of non-resectable liver metastases to prolong survival while maintaining a highest possible quality of life. Cryotherapy, which can be performed percutaneously and under magnetic resonance guidance, is one of these manifold therapeutic modalities, combining the inherent advantages of MRI with minimal invasiveness. Excellent visualization of the frozen liver tissue, precise tumor ablation, as well as an almost painless intervention due to the analgetic effect of the ice are implicating percutaneous cryotherapy as an attractive alternative to other ablation techniques. First clinical results are promising. However, meticulous and extensive long-term evaluation on a broad clinical scale is required. (orig.) [German] Die Prognose eines Patienten mit hepatischen Filiae haengt von den Behandlungsmoeglichkeiten des Primaertumors, vom Vorhandensein weiterer Metastasen und von der Ausdehnung und den Behandlungsmoeglichkeiten der Lebermetastasen selbst ab. Bei chirurigsch nicht resektablen Lebermetastasen kommen zahlreiche kurative oder palliative onkologische Therapiekonzepte in Frage, saemtlich mit dem Ziel einer moeglichst hohen Ueberlebensrate und Lebensqualitaet. Eine dieser Therapiestrategien ist die Kryotherapie, die perkutan unter kernspintomographischer Kontrolle durchgefuehrt werden kann und somit die inhaerenten Vorteile der MRT mit einem wenig invasiven Verfahren verbindet. Eine exzellente Darstellbarkeit gefrorenen Lebergewebes, eine praezise Tumorablation sowie ein nahezu schmerzfreier Eingriff aufgrund des analgetischen Effektes tiefer Temperaturen machen die perkutane Kryotherapie zu einer attraktiven Alternative zu anderen

  6. Mild cognitive impairment. Diagnostic value of different MR techniques; ''Mild cognitive impairment''. Diagnostische Wertigkeit verschiedener MR-Techniken

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, T.; Stieltjes, B.; Essig, M. [Deutsches Krebsforschungszentrum (DKFZ) Heidelberg, Abteilung E010 Radiologie, Heidelberg (Germany); Thomann, P.A. [Zentrum fuer Psychosoziale Medizin, Universitaetsklinikum Heidelberg, AG Strukturelle Bildgebung, Klinik fuer Allgemeine Psychiatrie, Heidelberg (Germany)

    2011-04-15

    In view of an increasingly aging population the prevalence of dementia is also expected to increase rapidly. As well as clinical, neuropsychological and laboratory procedures magnetic resonance imaging (MRI) plays an important role in the early diagnosis of dementia which is important in the precursor stage of mild cognitive impairment (MCI). On the one hand this stage is associated with an increased risk of dementia and on the other hand an early treatment in this stage could attenuate development of the disease. In addition to morphological changes different functional MRI techniques can help in the early diagnosis of dementia and the precursor stages. Moreover, it is important to detect those MCI patients who are at particularly risk for developing dementia. In the differentiation of converters to non-converters initial studies suggest that particularly voxel-based morphometry, MR spectroscopy and diffusion tensor imaging can provide important additional information. (orig.) [German] Angesichts einer immer aelter werdenden Bevoelkerung sind wir mit dem Problem einer zunehmenden Zahl an Patienten mit Demenzerkrankungen konfrontiert. In der Fruehdiagnostik einer Demenz spielen neben klinischen, neuropsychologischen und laborchemischen Untersuchungen nichtinvasive Bildgebungsverfahren wie die MRT eine bedeutende Rolle. Wichtig ist dabei die Fruehdiagnostik einer Demenz bereits im Vorstadium der leichten kognitiven Beeintraechtigung (''mild cognitive impairment'', MCI), da dieses Krankheitsbild mit einem deutlich erhoehten Demenzrisiko einhergeht und durch eine fruehzeitige Therapie der Krankheitsverlauf abgemildert oder deutlich verzoegert werden kann. Neben morphologischen Veraenderungen helfen verschiedene funktionelle MR-Verfahren bei der Fruehdiagnostik einer Demenz. Darueber hinaus ist es von grosser Bedeutung, diejenigen MCI-Patienten zu detektieren, die in besonderem Masse von einer Demenz bedroht sind. Bei der Differenzierung von

  7. Magnetic resonance tomography and computed tomography of the brain for diagnosing Wilson's disease

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Straube, A.; Beyer, H.K.; Leopold, H.C.

    1985-01-01

    The authors report on two woman patients with confirmed Wilson's desease (hepatolenticular degeneration) who had neurological deficits and showed typical changes evident from laboratory data. Both computed tomography and magnetic resonance tomography revealed degenerative changes in the basal ganglia, especially of the lenticular nucleus, MR showing these defects more clearly than CT. There was a noticeable symmetrical enhancement of signals in the lenticular nucleus which was particularly evident on the image basing on the T 2 (spin-spin relaxation time constant) values. MR could be superior to CT with regard to showing up pathological changes in the basal ganglia. The future indication of MR could be the establishment of an exact correlation between clinical signs and symptoms on the one hand, and morphological findings on the other. Over and above this, it should be explored to what extent MR can already detect degenerative changes in the brain in primarily hepatic types of the disease even without prior neurological examination. (orig.) [de

  8. Informative value of MR tomography using gadolinium-DTPA in the diagnosis of the lumbar post-discotomy syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, H.K.; Hoetzinger, H.; Toedt, C.; Oppel, U.

    1989-03-01

    Our results have shown that MR tomography - especially if gadolinium-DTPA is used as a contrast medium - is an excellent method to differentiate between the various possible causes of the post-discotomy syndrome. In particular, it is definitely possible to differentiate between a relapsed hernia of an intervertebral dis and a postoperative development of cicatricial tissue which is practically inevitable. This differentiation is of vital importance to the clinician, because a second operation should be performed only in case of a relapse, whereas cicatricial tissue is best left alone, because no matter how carefully the operation is performed with preparation of the neural structures, even more extensive cicatricial plates are bound to develop. Instability of the vertebral column in the operated disc segment, or other causes of complaints, can be identified via MR equally well if not better than by other means. Hence, the method should be the method of choice in postdiscotomy syndrome, since it facilitates the difficult choice between conservative therapy and reoperation.

  9. Comparison of MultiHance {sup trademark} and Gadovist {sup trademark} for cerebral MR perfusion imaging in healthy volunteers; Vergleich von MultiHance {sup trademark} und Gadovist {sup trademark} zur zerebralen MR-Perfusionsmessung bei gesunden Probanden

    Energy Technology Data Exchange (ETDEWEB)

    Essig, M.; LeHuu, M.; Huebener, M.; Kaick, G. van [Deutsches Krebsforschungszentrum, Abt. Radiologische Diagnostik und Therapie, Heidelberg (Germany); Lodemann, K.P. [Bracco-Byk, Gulden (Germany); Schoenberg, S.O. [Institut fuer Klinische Radiologie, Ludwig-Maximilians-Universitaet Muenchen, Grosshadern (Germany)

    2002-11-01

    *-gewichteten GRE-EPI-Sequenz in einfacher und doppelter Kontrastmitteldosierung durchgefuehrt. Die Schichtposition, Sequenzparameter und Kontrastmittelapplikation waren standardisiert. Zur quantitativen Analyse wurden rCBV- und rCBF-Messungen der normalen grauen und weissen Hirnsubstanz vorgenommen. Zusaetzlich wurde der prozentuale Signalverlust und die Halbwertsbreite der Signalzeitkurven ausgewertet.Die einfache Dosis wurde fuer beide Kontrastmittel als ausreichend fuer eine MR-Perfusionsmessung befunden. Der prozentuale Signalverlust (Gadovist {sup trademark} : 29,4% vs. MultiHance {sup trademark} : 28,3%) und die Halbwertsbreite des Signalverlustes (Gadovist {sup trademark} : 6,4 s vs. MultiHance {sup trademark} : 7,0 s) wie auch die errechneten Perfusionsparameter CBV und CBF waren bei beiden Kontrastmitteln in der einfachen Dosierung vergleichbar. Durch die deutlich laengere Infusionszeit fuer MultiHance in der doppelten Dosierung war die Halbwertsbreite hier deutlich erhoeht, jedoch ohne Auswirkung auf die Perfusionswerte rCBV und rCBF.Zusammengefasst hat das hoeher konzentrierte Gadovist {sup trademark} gegenueber dem staerker relaxierenden Kontrastmittel MultiHance {sup trademark} keine Vorteile fuer die MR-Perfusionsbildgebung. Beide Kontrastmittel erlauben die Berechnung qualitativ hochwertiger Perfusionsmaps in einer Dosierung von 0,1 mmol/kgbw mit identischen Qualitaetsparametern. (orig.)

  10. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  11. MRI and MRA of kidney transplants - evaluation of vessels and perfusion

    International Nuclear Information System (INIS)

    Wiesner, W.; Pfammatter, T.; Krestin, G.P.; Debatin, J.F.

    1998-01-01

    Purpose: To document the value of fast contrast enhanced-sequences in the assessment of the vascular supply and parenchymal perfusion in renal transplants. Patients: 18 recipients of a renal transplant were examined with a 1.5-Tesla-MR-system. The protocol included fast contrast enhanced 3D MR angiography and coronal 2D GRE sequences. The transplant artery and vein were assessed as well as regional parenchymal perfusion. Results: 3D MRA detected three transplant artery stenoses and one occlusion. In addition, two renal vein thromboses and one compression were identified. Perfusion deficits were documented in 8 renal transplants: Renal infarction (n=4), cortical necrosis (n=2), acute tubular necrosis (n=1) and venous ischemia (n=1). Fluid collections were documented as well as dilatation of the collecting system and abnormalities of the surrounding tissues. Conclusion: Contrast enhanced MRI and MRA permit a comprehensive assessment of renal transplants without inducing nephrotoxicity. (orig.) [de

  12. Tarsaltunnel syndrome - MRI diagnosis; Tarsaltunnelsyndrom. MR-Diagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Trattnig, S. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Osteoradiologie; Breitenseher, M. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Osteoradiologie; Haller, J. [Radiologische Abt., Hanuschkrankenhaus, Wien (Austria)]|[Ludwig Boltzmann-Institut fuer Osteologie, Wien (Austria); Helbich, T. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Osteoradiologie; Gaebler, C. [Universitaetsklinik fuer Unfallchirurgie, Wien (Austria); Imhof, H. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Osteoradiologie

    1995-07-01

    Clinical findings and symptoms of tarsal tunnel are commonly vague and diffuse and electrodiagnostic studies do not provide definitive diagnosis. MR imaging with its excellent soft tissue contrast can demonstrate clearly the anatomy of the tarsal tunnel and its contents. MRI is able to demonstrate a space-occypyinglesion and its relationship to the posterior tibial nerve and its branches. This information aids in surgical planning by determining the extent of the decompression required. MR imaging may also be used to follow up non-surgical causes of tarsal tunnel syndrome such as tenosynovitis. (orig.) [Deutsch] Klinische Befunde und Symptomoe des Tarsaltunnelsyndroms sind haeufig diffus, und elektrodiagnostische Untersuchungen liefern keine definitive Diagnose. Die MRT mit ihrem exzellenten Weichteilkontrast erlaubt eine ausgezeichnete Darstellung der Anatomie des Tarsaltunnels und seines Inhaltes. Die MRT ermoeglicht auch die Darstellung von raumfordernden Laesionen und ihre Beziehung zum N.tibialis posterior bzw. seiner Aeste. Diese Information hilft in der chirurigschen Planung, in dem das Ausmass der notwendigen Dekompression bestimmt werden kann. Die MRT ist auch geeignet als nichtinvasive Verlaufskontrolle von Ursachen eines Tarsaltunnelsyndroms, die keinen chirugischen Eingriff erfordern wie z.B. einer Tenosynovitis. (orig.)

  13. Assessment of renal artery stenosis of transplanted kidney by time resolved gadolinium-enhanced three-dimensional MR angiography. Preliminary phantom study and clinical evaluation

    International Nuclear Information System (INIS)

    Hayano, Toshio

    2001-01-01

    The purpose of this study was to determine a suitable imaging parameters of time-resolved Gd-enhanced three-dimensional MR angiography (TRE3DMRA) for the evaluation of renal artery stenosis of transplanted kidneys and to investigate the usefulness of TRE3DMRA in 166 clinical cases. Source images were obtained 3dFLASH with zero-filling interpolation (turbo MRA) using Siemens Magneton 1.5T. Acrylate tubes with 6 mm inner diameter filled with diluted Gd-DTPA were used as special phantoms. In the tubes, 25%, 50%, and 75% stenosis were made for simulating arterial stenosis, respectively. According to our clinical experiences, we decided 10 seconds or less acquisition time to obtaining renal artery images without overlapping with renal veins. To determine slice thickness, the degrees of stenosis of the phantom images obtained 8-second acquisition time in variable slice thickness were independently interpreted with visual inspection by two experienced diagnostic radiologists. One hundred sixty-six patients underwent renal transplantation were evaluated clinically. Using a power injector, 0.1 mmol/kg Gd-DTPA was injected after the test scan with 1 ml Gd-DTPA for the determination of acquisition timing. MR images were obtained in the following imaging parameters; 4-mm slice thickness and 8-second acquisition time based on the results of phantom studies. Source images were noted in oblique coronal direction encompassing the entire renal arteries from iliac arteries to renal hili. Based on phantom study, slice thickness must be less than 4-mm to demonstrate the significant stenotic portion (>50%) of the phantom simulating transplanted renal artery. In 150 of 166 patients, excellent images of renal arteries were obtained without overlapping with renal veins. Causes of poor images were mainly inadequate timing of image acquisition. We can decide the imaging parameters of TRE3DMRA for the evaluation of renal artery stenosis of transplanted kidneys. Using these parameters, in 150

  14. Charakterisierung von Antikörpern und ihrer immunsuppressiven Wirkung im präklinischen Transplantationsmodell des Hundes

    OpenAIRE

    Zorn, Julia

    2007-01-01

    Ziel der vorliegenden Arbeit war die Charakterisierung von Antikörpern und ihrer immunsuppressiven Wirkung im präklinischen Hundemodell. Dazu wurde eine T-Zelldepletionsmethode mit dem caninen CD6-Antikörper MT-606 und Kaninchen-komplement zur alleinigen GvHD-Prophylaxe bei der allogenen Knochenmark-transplantation entwickelt. Zusätzlich sollten die regulatorischen Eigenschaften von CD6-depletierten Knochenmarkzellen in vitro in der gemischten Lymphozytenkultur untersucht werden. Mit Hi...

  15. Magnetic resonance tomography (MR) of intracranial tumours: Contrast versus T2-weighted tomograms

    International Nuclear Information System (INIS)

    Schoerner, W.; Laniado, M.; Claussen, C.; Kazner, E.; Niendorf, H.P.; Felix, R.

    1986-01-01

    Nuclear magnetic resonance tomography was performed on 38 patients with intracranial tumours, before and after the administration of contrast, using a 0.35 T Magnetom. The MR examinations included various plain spin-echo sequences (SE 400/35, 800/35, 1600/35, 1600/70, 1600/105, 1600/120) as well as examinations after the iv-administration of gadolinium-DTPA (SE 800/35). On all occasions, the abnormalities were visible without contrast. Differentiation of tumour and its surroundings was possible in 19 out of 38 cases without contrast. Delineation of expansively growing tumours (eg. meningiomas) was possible in twelve out of 14 cases, but in only seven out of 24 cases with infiltrating tumours (eg. glioblastomas). On the other hand, clear differentiation between tumour and adjacent edema and normal brain, respectively, was possible in 35 out of 38 cases after Gadolinium-DTPA. (orig.) [de

  16. Practical Considerations for Clinical PET/MR Imaging.

    Science.gov (United States)

    Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan

    2018-01-01

    Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. MR imaging of the pulmonary vasculature - an update

    Energy Technology Data Exchange (ETDEWEB)

    Pedersen, Mark R.; Fisher, Mark T. [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); Beek, Edwin J.R. van [University of Iowa, Department of Radiology, Carver College of Medicine, Iowa City, Iowa (United States); University of Iowa Hospitals and Clinics, JPP 3895, Department of Radiology, Iowa City, Iowa (United States)

    2006-06-15

    Although the advent of multi-detector row computed tomography (CT) angiography has been at the heart of improving the diagnostic management of pulmonary vascular disease, MR technology has also moved forward. This review outlines the current state of affairs of MR techniques for the assessment of pulmonary vascular diseases such as pulmonary hypertension, pulmonary arteritis and arteriovenous malformations. It highlights the main areas of MR angiography and MR perfusion imaging and discusses novel methods, such as non-contrast enhanced direct thrombus imaging, and will discuss its merits in the context of other diagnostic modalities. (orig.)

  18. Acquired von Willebrand Syndrome Associated to Secondary IgM MGUS Emerging after Autologous Stem Cell Transplantation for AL Amyloidosis.

    Science.gov (United States)

    Qamar, Hina; Lee, Adrienne; Valentine, Karen; Skeith, Leslie; Jimenez-Zepeda, Victor H

    2017-01-01

    Acquired von Willebrand syndrome (AVWS) is a rare hemorrhagic disorder that occurs in patients with no prior personal or family history of bleeding. Here, we describe a case of AVWS occurring after autologous stem cell transplantation (ASCT). Interestingly, AVWS developed after bortezomib-based induction and conditioning regimens. Recent evidence suggests that the proximity of the bortezomib therapy to the collection of stem cells with consequent depletion of regulatory T cells after the conditioning regimen could explain some of the unusual autoimmune complications reported in patients receiving bortezomib prior to ASCT. In addition, this patient developed a secondary MGUS post-ASCT, which may have also contributed to the AVWS. To the best of our knowledge, this is the first case of post-ASCT AVWS reported. Prospective data is needed to better elucidate the mechanisms by which these unusual complications occur in patients receiving bortezomib prior to ASCT.

  19. Acquired von Willebrand Syndrome associated to secondary IgM MGUS emerging after Autologous Stem Cell Transplantation for AL Amyloidosis

    Directory of Open Access Journals (Sweden)

    Victor H Jimenez-Zepeda

    2017-05-01

    Full Text Available Acquired von Willebrand syndrome (AVWS is a rare hemorrhagic disorder that occurs in patients with no prior personal or family history of bleeding. Here, we describe a case of AVWS occurring after autologous stem cell transplantation (ASCT. Interestingly, AVWS developed after bortezomib-based induction and conditioning regimens. Recent evidence suggests that the proximity of the bortezomib therapy to the collection of stem cells with consequent depletion of regulatory T cells after the conditioning regimen could explain some of the unusual autoimmune complications reported in patients receiving bortezomib prior to ASCT. In addition, this patient developed a secondary MGUS post-ASCT, which may have also contributed to the AVWS. To the best of our knowledge, this is the first case of post-ASCT AVWS reported. Prospective data is needed to better elucidate the mechanisms by which these unusual complications occur in patients receiving bortezomib prior to ASCT.

  20. MR tomography of tetralogy of Fallot

    International Nuclear Information System (INIS)

    Stark, P.; Agness, M.; Holshouser, B.; Hinshaw, D. Jr.

    1991-01-01

    We present four patients with Tetralogy of Fallot, imaged with magnetic resonance. MRI is useful in clearly depicting the dilated ascending aorta, the infundibular stenosis, ventricular septal defect, right ventricular hypertrophy and dilated bronchial arteries. The pulmonary outflow tract can be visualized better with MR imaging than with ultrasound. (orig.) [de

  1. The informative value of MR tomography using gadolinium-DTPA in the diagnosis of the lumbar post-discotomy syndrome

    International Nuclear Information System (INIS)

    Beyer, H.K.; Hoetzinger, H.; Toedt, C.; Oppel, U.

    1989-01-01

    Our results have shown that MR tomography - especially if gadolinium-DTPA is used as a contrast medium - is an excellent method to differentiate between the various possible causes of the post-discotomy syndrome. In particular, it is definitely possible to differentiate between a relapsed hernia of an intervertebral dis and a postoperative development of cicatricial tissue which is practically inevitable. This differentiation is of vital importance to the clinician, because a second operation should be performed only in case of a relapse, whereas cicatricial tissue is best left alone, because no matter how carefully the operation is performed with preparation of the neural structures, even more extensive cicatricial plates are bound to develop. Instability of the vertebral column in the operated disc segment, or other causes of complaints, can be identified via MR equally well if not better than by other means. Hence, the method should be the method of choice in postdiscotomy syndrome, since it facilitates the difficult choice between conservative therapy and reoperation. (orig.) [de

  2. MR imaging of osteonecrosis using frequency selective chemical shift sequences; Neue Aspekte in der MR-Diagnostik der Osteonekrose: Selektive Fett/Wasser-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Duda, S H [Abt. fuer Radiologische Diagnostik, Tuebingen Univ. (Germany); Laniado, M [Abt. fuer Radiologische Diagnostik, Tuebingen Univ. (Germany); Schick, F [Inst. fuer Physik, Tuebingen Univ. (Germany)

    1994-12-31

    The MR appearance of osteonecrosis was assessed on selective fat- and water images to further evaluate the nature of double-line sign. Conventional T1- and T2-weighted SE and frequency selective chemical shift images of eight patients with avascular necrosis of the femoral head and three patients with bone infarcts were retrospectively reviewed. Eight of 11 patients showed a double-line sign on T2-weighted SE images. In these cases, correlation with selective water images revealed that a chemical shift artifact contributed to appearance and location of the hyperintense line. The authors conclude that chemical shift imaging improves our understanding of the nature of the double-line sign. (orig.) [Deutsch] Das MR-tomographische Erscheinungsbild der Osteonekrose auf selektiven Fett- und Wasserbildern wurde analysiert, um das in der Literatur beschriebene Doppellinienzeichen naeher zu untersuchen. Hierfuer wurden sowohl die herkoemmlichen T1- und T2-gewichteten Spin-Echo-Sequenzen herangezogen, als auch frequenzselektive Bilder, die aufgrund chemischer Verschiebung gewonnen wurden (1,5 T). Es wurden die Untersuchungen von acht Patienten mit avaskulaerer Hueftkopfnekrose und von drei Patienten mit Knocheninfarkten retrospektiv ausgewertet. Acht von 11 Patienten zeigten ein Doppellinienzeichen auf den T2-gewichteten Bildern. Die Korrelation mit den selektiven Wasserbildern ergab, dass durch chemische Verschiebung bedingte Artefakte das Erscheinungsbild und den Ort der hyperintensen Linie beeinflussten. Die Bildgebung mit Hilfe der chemischen Verschiebung verbessert unser Verstaendnis der MRT-Charakteristika der Osteonekrose. (orig.)

  3. Comparison of Positron Emission Tomography Quantification Using Magnetic Resonance- and Computed Tomography-Based Attenuation Correction in Physiological Tissues and Lesions: A Whole-Body Positron Emission Tomography/Magnetic Resonance Study in 66 Patients.

    Science.gov (United States)

    Seith, Ferdinand; Gatidis, Sergios; Schmidt, Holger; Bezrukov, Ilja; la Fougère, Christian; Nikolaou, Konstantin; Pfannenberg, Christina; Schwenzer, Nina

    2016-01-01

    Attenuation correction (AC) in fully integrated positron emission tomography (PET)/magnetic resonance (MR) systems plays a key role for the quantification of tracer uptake. The aim of this prospective study was to assess the accuracy of standardized uptake value (SUV) quantification using MR-based AC in direct comparison with computed tomography (CT)-based AC of the same PET data set on a large patient population. Sixty-six patients (22 female; mean [SD], 61 [11] years) were examined by means of combined PET/CT and PET/MR (11C-choline, 18F-FDG, or 68Ga-DOTATATE) subsequently. Positron emission tomography images from PET/MR examinations were corrected with MR-derived AC based on tissue segmentation (PET(MR)). The same PET data were corrected using CT-based attenuation maps (μ-maps) derived from PET/CT after nonrigid registration of the CT to the MR-based μ-map (PET(MRCT)). Positron emission tomography SUVs were quantified placing regions of interest or volumes of interest in 6 different body regions as well as PET-avid lesions, respectively. The relative differences of quantitative PET values when using MR-based AC versus CT-based AC were varying depending on the organs and body regions assessed. In detail, the mean (SD) relative differences of PET SUVs were as follows: -7.8% (11.5%), blood pool; -3.6% (5.8%), spleen; -4.4% (5.6%)/-4.1% (6.2%), liver; -0.6% (5.0%), muscle; -1.3% (6.3%), fat; -40.0% (18.7%), bone; 1.6% (4.4%), liver lesions; -6.2% (6.8%), bone lesions; and -1.9% (6.2%), soft tissue lesions. In 10 liver lesions, distinct overestimations greater than 5% were found (up to 10%). In addition, overestimations were found in 2 bone lesions and 1 soft tissue lesion adjacent to the lung (up to 28.0%). Results obtained using different PET tracers show that MR-based AC is accurate in most tissue types, with SUV deviations generally of less than 10%. In bone, however, underestimations can be pronounced, potentially leading to inaccurate SUV quantifications. In

  4. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Science.gov (United States)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Aarsvold, John N.; Raghunath, Nivedita; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.; Votaw, John R.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [11C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR

  5. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Fei, Baowei, E-mail: bfei@emory.edu [Department of Radiology and Imaging Sciences, Emory University School of Medicine, 1841 Clifton Road Northeast, Atlanta, Georgia 30329 (United States); Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia 30322 (United States); Department of Mathematics and Computer Sciences, Emory University, Atlanta, Georgia 30322 (United States); Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Aarsvold, John N. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Nuclear Medicine Service, Atlanta Veterans Affairs Medical Center, Atlanta, Georgia 30033 (United States); Cervo, Morgan; Stark, Rebecca [The Medical Physics Graduate Program in the George W. Woodruff School, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Meltzer, Carolyn C. [Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia 30329 (United States); Department of Neurology and Department of Psychiatry and Behavior Sciences, Emory University School of Medicine, Atlanta, Georgia 30322 (United States)

    2012-10-15

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  6. MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

    International Nuclear Information System (INIS)

    Fei, Baowei; Yang, Xiaofeng; Nye, Jonathon A.; Raghunath, Nivedita; Votaw, John R.; Aarsvold, John N.; Cervo, Morgan; Stark, Rebecca; Meltzer, Carolyn C.

    2012-01-01

    Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with ["1"1C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

  7. MR-guided percutaneous nephrostomy of the contrast-enhanced, nondilated upper urinary tract: initial experimental results; MR-tomographisch gesteuerte perkutane Nephrostomie des kontrastangehobenen, nicht dilatierten oberen Harntraktes: Erste experimentelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Buecker, A.; Neuerburg, J.M.; Adam, G.B.; Guenther, R.W. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik; Hunter, D.W. [Minnesota Univ. (United States). Dept. of Radiology

    1998-06-01

    Purpose: To evaluate technique and practicability of MR-guided percutaneous nephrostomy (MRPCN) in an animal model. Methods: In three domestic pigs, a unilateral percutaneous nephrostomy tube was placed into the nondilated collecting system using exclusively MR-guidance with a standard 1.5 T scanner. The urinary tract was visualized by intravenous injection of Gd-DTPA and low-dose furosemide. The entire interventional procedure was controlled using a T{sub 1}-weighted `dual stack` 2D TFE sequence in two orthogonal planes. Results: In all three animals, the puncture needle was safely directed into the nondilated target calyx. Even slight deviations of the needle from the optimal path were readily detected on both MR image planes which enabled immediate correction. This technique successfully achieved a `first attempt` puncture of the targeted calyx in each animal. Over a nitinol guidewire a 5 F catheter was placed into the renal pelvis. Its dysprosium labelled tip was acurately delineated on contrast-enhanced MR images. Conclusions: Percutaneous nephrostomy under MR guidance is a very feasible technique for puncturing the nondilated pelvicalyceal system. This procedure offers some advantages over the current standard modalities. (orig.) [Deutsch] Ziel: Ueberpruefung von Technik und Durchfuehrbarkeit einer MR-tomographisch gesteuerten perkutanen Nephrostomie (MR-PNS) im Tierexperiment. Methoden: Bei drei Hausschweinen wurde eine einseitige perkutane Nephrostomie des nicht dilatierten Hohlraumsystems ausschliesslich unter MR-tomographischer Kontrolle mit einem geschlossenen 1,5-T-System durchgefuehrt. Die Kontrastierung des oberen Harntraktes erfolgte durch eine intravenoese Injektion von Gd-DTPA und niedrigdosiertem Furosemid. Die einzelnen Interventionsschritte wurden mit einem T{sub 1}-gewichteten `Doppel-Schichtstapel` 2D-TFE Sequenz in zwei orthogonalen Schichtebenen kontrolliert. Ergebnisse: Bei allen drei Versuchstieren liess sich die Punktionsnadel unter MR

  8. Osteonecrosis of the femoral head after bone marrow transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Mi; Jun, Jeong Su; Park, Chang Suk; Kim, Yong Sik; Kwon, Soon Yong; Kim, Yoo Jin; Kim, Chun Choo [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    2003-07-01

    To retrospectively review findings of osteonecrosis of the femoral head after bone marrow transplantation. We reviewed the clinical and MR findings of osteonecrosis of the femoral head in 23 of 1112 patients who underwent marrow transplantation during a five-year follow-up period lasting from 1996 to 2000. Mean age at the time of diagnosis was 31 (range, 20-47) years, and the mean time from transplant to diagnosis was 17 months. All patients developed variable graft-versus-host disease and seventeen were treated with high-dose prednisolone and/or cysclosporin for severe acute or extensive chronic graft versus host disease. Osteonecrosis was diagnosed by magnetic resonance (MR) imaging, which allowed early detection of disease assessment of its stage. At the time of diagnosis, 15 hips were at stage I, 28 at stage II, two at stage III, and none at stage IV, according to the international ARCO classification system. Osteonecrosis of femoral diaphyses, the lower lumbar spine, or pelvic bones in the MR field was also found to have occurred in 11 patients. Initial treatment was conservative: 21 hips underwent surgery [core decompression (n=10), vascularized fibular bone graft (n=5), and joint replacement (n=6)]. In patients receiving high-dose steroids for the treatment of graft-versus-host disease, MR screening might help detect osteonecrosis at an early stage.

  9. Safety issues and updates under MR environments

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jung; Kim, Kyung Ah, E-mail: bellenina@daum.net

    2017-04-15

    Highlights: • Unexpected biological effects can occur within stronger magnetic fields. • MR safety for MR conditional items is not guaranteed beyond the tested conditions. • Updated knowledge about MR-related safety is important for a safe MR environment. - Abstract: Magnetic resonance (MR) imaging is a useful imaging tool with superior soft tissue contrast for diagnostic evaluation. The MR environments poses unique risks to patients and employees differently from ionizing radiation exposure originated from computed tomography and plain x-ray films. The technology associated with MR system has evolved continuously since its introduction in the late 1970s. MR systems have advanced with static magnetic fields, faster and stronger gradient magnetic fields and more powerful radiofrequency transmission coils. Higher field strengths of MR offers greater signal to noise capability and better spatial resolution, resulting in better visualization of anatomic detail, with a reduction in scan time. With the rapid evolution of technology associated with MR, we encounter new MR-related circumstances and unexpected dangerous conditions. A comprehensive update of our knowledge about MR safety is necessary to prevent MR-related accidents and to ensure safety for patients and staff associated with MR. This review presents an overview about MR-related safety issues and updates.

  10. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    Science.gov (United States)

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations

  11. CT and MR imaging of the kidney and adrenal glands: MR imaging of the kidney and adrenal glands

    International Nuclear Information System (INIS)

    Lee, J.K.T.

    1987-01-01

    The normal anatomy of the kidney is clearly demonstrated with MR imaging. The renal cortex can be differentiated from the renal medulla; renal vessels can also be identified. MR imaging can differentiate cystic from solid lesions. The signal intensity of a renal cell carcinoma varies and overlaps with the signal intensities of renal neoplasms of other etiologies. MR imaging is superior to CT in distinguishing vascular from nonvascular structures. It can distinguish collateral vessels from lymph nodes and can disclose tumoral thrombi. MR imaging can also aid in the differentiation of acute rejection from acute tubular necrosis in renal transplant recipients. Both normal and abnormal adrenal glands can be seen on MR imaging. A normal adrenal gland has a signal intensity higher than or equal to that of muscle but lower than that of fat. T1-weighted images offer excellent antomic resolution; T2-weighted images provide additional information about internal characteristics of adrenal neoplasms. Preliminary data indicate that MR imaging is useful in distinguishing nonfunctioning adenomas from adrenal metastases. The role of MR imaging of the kidney and adrenal gland is discussed

  12. Preoperative examination of potential renal transplant donors: value of gadolinium-enhanced 3D-MR-angiography in comparison with DSA and urography

    International Nuclear Information System (INIS)

    Winterer, J.T.; Paul, G.; Einert, A.; Altehoefer, C.; Uhrmeister, P.; Laubenberger, J.

    2000-01-01

    Purpose: To assess a contrast-enhanced standardized MRA protocol for the presurgical evaluation of potential renal transplant donors. Methods: Twenty-three potential donors for renal transplantations were examined with gadolinium-enhanced, two-phase MR angiograms (1.5 T) and DSA/urography for the number of renal arteries, the presence of aberrant arterial and venous branches, renal artery stenoses and anatomy of the renal collecting system and ureters. The diagnostic value was assessed by evaluating different image processing modalities and interobserver variability. Results: Using maximum intensity projections (MIP) together with multiplanar reformatting (MPR), accessory arteries were detected with a sensitivity/specificity of 100%/98%. Depending on diagnostic experience, exclusive evaluation of MIP yielded a sensitivitiy/specificity of 67-100%/95-100%. Using MIP/MPR, venous depiction was good in 80%, with MIP solely in 30-40%. At least the proximal third of the ureter was visible in 67%. Conclusion: MPR/MIP evaluation of two-phase, contrast-enhanced MRA provides an excellent depiction of renal vessel anatomy for presurgical evaluation of renal transplant donors. Exclusive MIP assessment is less reliable and depends strongly on the examiner's experience. For sufficient visualization of the ureters, either additional measurements or low-dose diuretic injection have to be performed. (orig.) [de

  13. Imaging in pancreatic transplants

    International Nuclear Information System (INIS)

    Heller, Matthew T; Bhargava, Puneet

    2014-01-01

    Pancreatic transplantation, performed alone or in conjunction with kidney transplantation, is an effective treatment for advanced type I diabetes mellitus and select patients with type II diabetes mellitus. Following advancements in surgical technique, postoperative management, and immunosuppression, pancreatic transplantation has significantly improved the length and quality of life for patients suffering from pancreatic dysfunction. While computed tomography (CT) and magnetic resonance imaging (MRI) have more limited utility, ultrasound is the preferred initial imaging modality to evaluate the transplanted pancreas; gray-scale assesses the parenchyma and fluid collections, while Doppler interrogation assesses vascular flow and viability. Ultrasound is also useful to guide percutaneous interventions for the transplanted pancreas. With knowledge of the surgical anatomy and common complications, the abdominal radiologist plays a central role in the perioperative and postoperative evaluation of the transplanted pancreas

  14. Labeling human embryonic stem-cell-derived cardiomyocytes for tracking with MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda, Rosalinda T.; Daldrup-Link, Heike [Lucile Packard Children' s Hospital, Stanford School of Medicine, Pediatric Radiology, Stanford, CA (United States); Boddington, Sophie; Wendland, Mike; Mandrussow, Lydia [University of California, Department of Radiology and Biomedical Imaging, UCSF Medical Center, San Francisco, CA (United States); Henning, Tobias D. [University Hospital of Cologne, Department of Radiology and Neuroradiology, Cologne (Germany); Liu, Siyuan [National Institutes of Health, Language Section, Voice, Speech and Language Branch, National Institute on Deafness and Other Communication Disorders, Bethesda, MD (United States)

    2011-11-15

    Human embryonic stem cells (hESC) can generate cardiomyocytes (CM), which offer promising treatments for cardiomyopathies in children. However, challenges for clinical translation result from loss of transplanted cell from target sites and high cell death. An imaging technique that noninvasively and repetitively monitors transplanted hESC-CM could guide improvements in transplantation techniques and advance therapies. To develop a clinically applicable labeling technique for hESC-CM with FDA-approved superparamagnetic iron oxide nanoparticles (SPIO) by examining labeling before and after CM differentiation. Triplicates of hESC were labeled by simple incubation with 50 {mu}g/ml of ferumoxides before or after differentiation into CM, then imaged on a 7T MR scanner using a T2-weighted multi-echo spin-echo sequence. Viability, iron uptake and T2-relaxation times were compared between groups using t-tests. hESC-CM labeled before differentiation demonstrated significant MR effects, iron uptake and preserved function. hESC-CM labeled after differentiation showed no significant iron uptake or change in MR signal (P < 0.05). Morphology, differentiation and viability were consistent between experimental groups. hESC-CM should be labeled prior to CM differentiation to achieve a significant MR signal. This technique permits monitoring delivery and engraftment of hESC-CM for potential advancements of stem cell-based therapies in the reconstitution of damaged myocardium. (orig.)

  15. Labeling human embryonic stem-cell-derived cardiomyocytes for tracking with MR imaging

    International Nuclear Information System (INIS)

    Castaneda, Rosalinda T.; Daldrup-Link, Heike; Boddington, Sophie; Wendland, Mike; Mandrussow, Lydia; Henning, Tobias D.; Liu, Siyuan

    2011-01-01

    Human embryonic stem cells (hESC) can generate cardiomyocytes (CM), which offer promising treatments for cardiomyopathies in children. However, challenges for clinical translation result from loss of transplanted cell from target sites and high cell death. An imaging technique that noninvasively and repetitively monitors transplanted hESC-CM could guide improvements in transplantation techniques and advance therapies. To develop a clinically applicable labeling technique for hESC-CM with FDA-approved superparamagnetic iron oxide nanoparticles (SPIO) by examining labeling before and after CM differentiation. Triplicates of hESC were labeled by simple incubation with 50 μg/ml of ferumoxides before or after differentiation into CM, then imaged on a 7T MR scanner using a T2-weighted multi-echo spin-echo sequence. Viability, iron uptake and T2-relaxation times were compared between groups using t-tests. hESC-CM labeled before differentiation demonstrated significant MR effects, iron uptake and preserved function. hESC-CM labeled after differentiation showed no significant iron uptake or change in MR signal (P < 0.05). Morphology, differentiation and viability were consistent between experimental groups. hESC-CM should be labeled prior to CM differentiation to achieve a significant MR signal. This technique permits monitoring delivery and engraftment of hESC-CM for potential advancements of stem cell-based therapies in the reconstitution of damaged myocardium. (orig.)

  16. A case of hemorrhagic pineal cyst: MR/CT correlation

    International Nuclear Information System (INIS)

    Osborn, R.E.

    1989-01-01

    A 30-year-old male had headache pain for one month and was evaluated with both computed tomography (CT) and magnetic resonance (MR). These scans demonstrated an obstructing pineal cyst containing layered acute and subacute blood products by MR criteria. The concurrent scans allowed correlation between CT and MR findings in this rare complication of an unusual entity, explained his headache (and the development of later upward gaze paresis), provided a precise surgical/anatomic approach, and gave a good final clinical result. The report illustrates appropriate CT and MR images and pathological specimen. (orig.)

  17. Gd-DTPA administered MR imaging of intracranial mass lesions

    International Nuclear Information System (INIS)

    Mihara, Futoshi; Hirakata, Ryosuke; Hasuo, Kanehiro; Yasumori, Kotaro; Yoshida, Kisaku; Kuroiwa, Toshiro; Masuda, Kouji; Fukui, Masashi

    1989-01-01

    Magnetic resonance (MR) images of 13 intracranial mass lesions taken with the intravenous administration of gadolinium-DTPA were evaluated in comparison with precontrast computed tomography (CT), postcontrast CT, and precontrast MR. In the MR images taken with Gd-DTPA, tumor delineation improved in eight of 13 cases (62%) in comparison with precontrast MR images, and in seven of 13 cases (54%) in comparison with the overall evaluation of precontrast CT, postcontrast CT, and precontrast MR images. Tumor demarcation was unchanged in the remaining cases; no deterioration was observed with Gd-DTPA administration. MR imaging with Gd-DTPA should be performed to better evaluate the extent of intracranial mass lesions and to provide additional information. (author)

  18. Growth Plate Flow and Metabolism Screening Using MR: A New Application for Specialized MR Sequences

    DEFF Research Database (Denmark)

    Shiguetomi Medina, Juan Manuel; Stødkilde-Jørgensen, Hans; Rahbek, Ole

    . Methods Four normal pig frozen tibiae were studied. Tomography, MR T1 and T2 sequences were performed and compared. Apparent Diffusion Coefficient and Surface Tension Images were also performed and analyzed. Finally, methylmethacrylate embedding histology was performed using hematoxylin-eosin, toluidine...

  19. Quantitative evaluation of native lung hyperinflation after single lung transplantation for emphysema using three-dimensional computed tomography volumetry.

    Science.gov (United States)

    Motoyama, H; Chen, F; Ohsumi, A; Hijiya, K; Takahashi, M; Ohata, K; Yamada, T; Sato, M; Aoyama, A; Bando, T; Date, H

    2014-04-01

    Although double lung transplantation is performed more frequently for emphysema, single lung transplantation (SLT) continues to be performed owing to limited donor organ availability. Native lung hyperinflation (NLH) is a unique complication following SLT for emphysema. Three-dimensional computed tomography (3D-CT) volumetry has been introduced into the field of lung transplantation, which we used to assess NLH in emphysema patients undergoing SLT. The primary purpose of this study was to confirm the effectiveness of 3D-CT volumetry in the evaluation of NLH following SLT for emphysema. In 5 emphysema patients undergoing SLT at Kyoto University Hospital, 3D-CT volumetry data, pulmonary function test results, and clinical and radiological findings were retrospectively evaluated. Three patients did not develop a significant mediastinal shift, whereas the other 2 patients developed a mediastinal shift. In the 3 patients without a mediastinal shift, 3D-CT volumetry did not show a significant increase in native lung volume. These patients had a history of sternotomy prior to lung transplantation and firm adhesion on the mediastinal side was detected during lung transplantation. One of 2 patients with a mediastinal shift developed severe dyspnea with significantly decreased pulmonary function, and 3D-CT volumetry showed a significant increase in the native lung volume. However, the other patient did not show any dyspnea and his native lung volume decreased postoperatively (preoperatively to 6 months postoperatively: +981 mL and -348 mL, respectively). Although bilateral lung transplantation has become preferable for emphysema patients owing to postoperative NLH with SLT, patients with a history of sternotomy prior to lung transplantation might be good candidates for SLT. 3D-CT volumetry may be a useful method for detection of NLH. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. MR spectroscopy-based brain metabolite profiling in propionic acidaemia: metabolic changes in the basal ganglia during acute decompensation and effect of liver transplantation

    Directory of Open Access Journals (Sweden)

    McKiernan Patrick J

    2011-05-01

    Full Text Available Abstract Background Propionic acidaemia (PA results from deficiency of Propionyl CoA carboxylase, the commonest form presenting in the neonatal period. Despite best current management, PA is associated with severe neurological sequelae, in particular movement disorders resulting from basal ganglia infarction, although the pathogenesis remains poorly understood. The role of liver transplantation remains controversial but may confer some neuro-protection. The present study utilises quantitative magnetic resonance spectroscopy (MRS to investigate brain metabolite alterations in propionic acidaemia during metabolic stability and acute encephalopathic episodes. Methods Quantitative MRS was used to evaluate brain metabolites in eight children with neonatal onset propionic acidaemia, with six elective studies acquired during metabolic stability and five studies during acute encephalopathic episodes. MRS studies were acquired concurrently with clinically indicated MR imaging studies at 1.5 Tesla. LCModel software was used to provide metabolite quantification. Comparison was made with a dataset of MRS metabolite concentrations from a cohort of children with normal appearing MR imaging. Results MRI findings confirm the vulnerability of basal ganglia to infarction during acute encephalopathy. We identified statistically significant decreases in basal ganglia glutamate+glutamine and N-Acetylaspartate, and increase in lactate, during encephalopathic episodes. In white matter lactate was significantly elevated but other metabolites not significantly altered. Metabolite data from two children who had received liver transplantation were not significantly different from the comparator group. Conclusions The metabolite alterations seen in propionic acidaemia in the basal ganglia during acute encephalopathy reflect loss of viable neurons, and a switch to anaerobic respiration. The decrease in glutamine + glutamate supports the hypothesis that they are consumed to

  1. Cerebral MR imaging of malignant melanoma; Zerebrale MR-Bildgebung beim malignen Melanom

    Energy Technology Data Exchange (ETDEWEB)

    Breckwoldt, M.; Bendszus, M. [Universitaetsklinikum Heidelberg, Abteilung Neuroradiologie, Neurologische Klinik, Heidelberg (Germany)

    2015-01-16

    even in asymptomatic patients. Stage IV requires quarterly MRI examinations. Melanotic and amelanotic metastases show different MRI characteristics. The differentiation between metastasis and microbleeding can be impossible and might require a follow-up scan. Susceptibility-weighted imaging increases the sensitivity of metastases detection but lacks specificity. It can help to differentiate between different metastatic entities. (orig.) [German] Das maligne Melanom (MM) ist nach dem Bronchial- und Mammakarzinom die dritthaeufigste Tumorentitaet, die in das ZNS metastasiert. Haeufig geschieht dies frueh im Krankheitsverlauf, was fuer die Prognose entscheidend ist. Zehn bis 40 % aller Patienten sterben an einer intrakraniellen Metastasierung, wobei die Inzidenz von Hirnmetastasen noch deutlich hoeher liegt (50-75 %). Praedilektionsstelle ist das subkortikale Marklager. Das Signalverhalten von Melanommetastasen kann sehr unterschiedlich sein und sich im Krankheitsverlauf, abhaengig von Melaningehalt, Akkumulation paramagnetischer Ionen und Einblutungen, aendern. Die neuen spezifischen Therapien (Immuntherapien und Kinaseinhibitoren) stellen auch fuer die Bildgebung eine Herausforderung dar, weil bislang nicht ausreichend geklaert ist, inwieweit diese das Signalverhalten von Metastasen in der MR-Bildgebung aendern. Zudem koennen unter den neuen Therapien immunassoziierte Pathologien (Hypophysitis bei ca. 5 % der Patienten unter Ipilimumab-Therapie) und granulomatoese Erkrankungen (Neurosarkoidose) auftreten. In der CT stellen sich Melanommetastasen haeufig nativ hyperdens dar. In der MRT sind T2w-Fluid-attenuated-inversion-recovery(FLAIR)-, native T1w- sowie T1w-Sequenzen nach Kontrastmittelgabe obligat. Mehrere Schnittebenen sollten akquiriert werden. Die suszeptibilitaetsgewichtete Bildgebung (SWI) ist eine neue sensitive Methode zur Detektion von Melanommetastasen bei jedoch eingeschraenkter Spezifitaet. Etwa 66 % der Melanommetastasen zeigen ausgepraegte intratumorale

  2. The role of positron emission tomography with 18F-fluorodeoxyglucose integrated with computed tomography in the evaluation of patients with multiple myeloma undergoing allogeneic stem cell transplantation.

    Science.gov (United States)

    Patriarca, Francesca; Carobolante, Francesca; Zamagni, Elena; Montefusco, Vittorio; Bruno, Benedetto; Englaro, Emanuaela; Nanni, Cristina; Geatti, Onelio; Isola, Miriam; Sperotto, Alessandra; Buttignol, Silvia; Stocchi, Raffaella; Corradini, Paolo; Cavo, Michele; Fanin, Renato

    2015-06-01

    Positron emission tomography (PET) integrated with computed tomography (PET/CT) has been reported to be useful for screening myelomatous lesions at diagnosis in patients with multiple myeloma (MM) and for monitoring response to autologous stem cell transplantation (auto-SCT). The aim of the study was to evaluate the prognostic significance of PET/CT in MM patients who received allogeneic stem cell transplantation (allo-SCT). Patients who underwent upfront auto-SCT followed by allo-SCT, either as consolidation or salvage treatment, were studied with PET/CT before and/or within 6 months after allo-SCT. The number, the maximum standard uptake value (SUV), and the location (medullary or extramedullary) of focal lesions (FLs) were recorded and investigated as predictors of progression-free survival (PFS) and overall survival (OS) by univariate and multivariate analyses. Fifty-four patients had a PET/CT scan before allo-SCT. Of these, 22 patients (41%) had a negative PET/CT scan, 11 patients (20%) showed 1 to 3 FLs, and 21 patients (39%) had either a diffuse bone marrow involvement or more than 3 FLs. SUV was >4.2 in 21 patients (39%) and extramedullary disease (EMD) was present in 6 patients (11%). Multivariate analysis of prognostic factors before allo-SCT showed that persistence of EMD at transplantation was an independent predictor of poor PFS, whereas OS was negatively influenced by unrelated donor and SUV > 4.2. Fifty-nine patients had a PET/CT scan within 6 months after allo-SCT. Multivariate analysis of post-treatment variables showed that persistence of EMD and failure to obtain complete response or very good partial response after allo-SCT were strongly associated with shorter PFS and OS. Of the 46 patients with evaluable PET/CT scans both before and 6 months after allo-SCT, the 23 patients who maintained or reached a PET complete remission showed a significantly prolonged PFS and OS compared with the 23 patients with persistence of any PET positivity (2-year

  3. A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer

    International Nuclear Information System (INIS)

    Dregely, Isabel; Lanz, Titus; Mueller, Matthias F.; Metz, Stephan; Kuschan, Marika; Nimbalkar, Manoj; Ziegler, Sibylle I.; Nekolla, Stephan G.; Schwaiger, Markus; Bundschuh, Ralph A.; Haase, Axel

    2015-01-01

    To implement and evaluate a dedicated receiver array coil for simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging in breast cancer. A 16-channel receiver coil design was optimized for simultaneous PET/MR imaging. To assess MR performance, the signal-to-noise ratio, parallel imaging capability and image quality was evaluated in phantoms, volunteers and patients and compared to clinical standard protocols. For PET evaluation, quantitative 18 F-FDG PET images of phantoms and seven patients (14 lesions) were compared to images without the coil. In PET image reconstruction, a CT-based template of the coil was combined with the MR-acquired attenuation correction (AC) map of the phantom/patient. MR image quality was comparable to clinical MR-only examinations. PET evaluation in phantoms showed regionally varying underestimation of the standardised uptake value (SUV; mean 22 %) due to attenuation caused by the coil. This was improved by implementing the CT-based coil template in the AC (<2 % SUV underestimation). Patient data indicated that including the coil in the AC increased the SUV values in the lesions (21 ± 9 %). Using a dedicated PET/MR breast coil, state-of-the-art MRI was possible. In PET, accurate quantification and image homogeneity could be achieved if a CT-template of this coil was included in the AC for PET image reconstruction. (orig.)

  4. Pancreas transplants

    International Nuclear Information System (INIS)

    Chandra, J.; Phillips, R.R.; Boardman, P.; Gleeson, F.V.; Anderson, E.M.

    2009-01-01

    Cadaveric, whole pancreas transplantation has proved an effective therapy in the treatment of long-standing type 1 diabetes mellitus and is capable of achieving an insulin-independent eugyclaemic state. As a result, this procedure is being increasingly performed. However, the surgical procedure is complex and unfamiliar to many radiologists. Imaging with computed tomography (CT) and magnetic resonance imaging (MRI) gives excellent results and can be used confidently to diagnose vascular, enteric, and immune-mediated complications. We present a review of the normal post-transplantation appearance and the features of early and late complications.

  5. Pancreas transplants

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, J.; Phillips, R.R.; Boardman, P.; Gleeson, F.V. [Department of Radiology, Churchill Hospital, Headington, Oxford (United Kingdom); Anderson, E.M. [Department of Radiology, Churchill Hospital, Headington, Oxford (United Kingdom)], E-mail: ewan.anderson@orh.nhs.uk

    2009-07-15

    Cadaveric, whole pancreas transplantation has proved an effective therapy in the treatment of long-standing type 1 diabetes mellitus and is capable of achieving an insulin-independent eugyclaemic state. As a result, this procedure is being increasingly performed. However, the surgical procedure is complex and unfamiliar to many radiologists. Imaging with computed tomography (CT) and magnetic resonance imaging (MRI) gives excellent results and can be used confidently to diagnose vascular, enteric, and immune-mediated complications. We present a review of the normal post-transplantation appearance and the features of early and late complications.

  6. Magnetic resonance tomography in confirmed multiple sclerosis

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Dickmann, E.; Beyer, H.K.; Gehlen, W.; Josef-Hospital, Bochum; Knappschafts-Krankenhaus Bochum

    1985-01-01

    The authors report on 21 cases of confirmed multiple sclerosis examined by both CT and magnetic resonance tomography. To safeguard the results, strict criteria were applied in accordance with the suggestions made by neurological work teams. Pathological lesons were seen in 20 patients; the MR image did not reveal anything abnormal in one case. On the average, 10.3 lesions were seen in the MR tomogram, whereas CT images showed on the average only 2.1 foci. The size and number of lesions in the MR tomogram were independent of the duration of the disease, the presented clinical symptoms, or the type of treatment at the time of examination. Evidently the sensitivity of MR tomography is very high in MS patients, but it has not yet been clarified to what extent this applies also to the specificity. Further research is mandatory. First experiences made by us show that lesions of a similar kind can also occur in diseases such as malignant lymphoma involving the brain, in vitamin B 12 deficiency syndrome, or encephalitis, and can become manifest in the MR tomogram. (orig.) [de

  7. Experimental MR-guided cryotherapy of the brain with almost real-time imaging by radial k-space scanning; Experimentelle MR-gesteuerte Kryotherapie des Gehirns mit nahezu Echtzeitdarstellung durch radiale k-Raum-Abtastung

    Energy Technology Data Exchange (ETDEWEB)

    Tacke, J.; Schorn, R.; Glowinski, A.; Grosskortenhaus, S.; Adam, G.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Speetzen, R.; Rau, G. [Helmholtz-Institut fuer Biomedizinische Technik, Aachen (Germany); Rasche, V. [Philips GmbH Forschungslaboratorium, Hamburg (Germany)

    1999-02-01

    Purpose: To test radial k-space scanning by MR fluoroscopy to guide and control MR-guided interstitial cryotherapy of the healthy pig brain. Methods: After MR tomographic planning of the approach, an MR-compatible experimental cryotherapy probe of 2.7 mm diameter was introduced through a 5 mm burr hole into the right frontal brain of five healthy pigs. The freeze-thaw cycles were imaged using a T{sub 1}-weighted gradient echo sequence with radial k-space scanning in coronal, sagittal, and axial directions. Results: The high temporal resolution of the chosen sequence permits a continuous representation of the freezing process with good image quality and high contrast between ice and unfrozen brain parenchyma. Because of the interactive conception of the sequence the layer plane could be chosen as desired during the measurement. Ice formation was sharply demarcated, spherically configurated, and was free of signals. Its maximum diameter was 13 mm. Conclusions: With use of the novel, interactively controllable gradient echo sequence with radial k-space scanning, guidance of the intervention under fluoroscopic conditions with the advantages of MRT is possible. MR-guided cryotherapy allows a minimally-invasive, precisely dosable focal tissue ablation. (orig.) [Deutsch] Ziel: Erprobung der radialen k-Raum-Abtastung bei der MR-Fluoroskopie zur Steuerung und Kontrolle MR-gesteuerter interstitieller Kryotherapie des gesunden Schweinegehirns. Methoden: Nach MR-tomographischer Planung des Zugangsweges wurde eine MR-kompatible experimentelle Kryotherapiesonde von 2,7 mm Durchmesser ueber ein 5 mm Bohrloch in das rechte Frontalhirn von fuenf gesunden Schweinen eingebracht. Die Frier-/Tauzyklen wurden anhand einer T{sub 1}-gewichteten Gradientenechosequenz mit radialer k-Raum-Abtastung in koronarer, sagittaler und axialer Schichtfuehrung dargestellt. Ergebnisse: Die hohe zeitliche Aufloesung der gewaehlten Sequenz erlaubte eine kontinuierliche Darstellung des Friervorgangs bei

  8. The von Meyenburg complex; Der von Meyenburg Komplex

    Energy Technology Data Exchange (ETDEWEB)

    Schwab, S.A.; Bautz, W.; Uder, M.; Kuefner, M.A. [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. fuer Radiologie

    2008-07-01

    The von Meyenburg complex (VMC) describes bile duct hamartomas and presents a rare, benign incidental finding in liver imaging. We report on a 61-year-old man, who was referred for a follow up study 14 years after remission of Hodgkin's disease. Computed tomography (CT) revealed multiple hypodense lesions throughout the liver, primary suggesting recurrent Hodgkin's disease. Previous CT-examinations, which were obtained at a later date, showed those lesions in identical distribution and morphology over the years, leading to diagnosis of multiple bile duct hamartomas (VMC). Making imaging-based diagnosis of VMC including ultrasound, CT and magnetic resonance imaging is a challenging task for the radiologist. Based on literature research findings, the impact of different modalities in the diagnostic work-up of VMC is discussed. (orig.)

  9. Duplex sonography and magnetic resonance imaging in the clarification of nephrological complications after renal transplant

    International Nuclear Information System (INIS)

    Gueckel, C.; Krestin, G.P.; Wienand, P.

    1989-01-01

    A prospective study compared Duplex sonography and magnetic resonance imaging in evaluating renal transplant. Hundred and two Duplex sonographic and 24 MR examinations were performed and correlated with clinical course or biopsy. All normal renal allografts, 6 transplants with acute tubular necrosis and 2 cases of cyclosporin toxicity had normal Doppler waveforms, whereas 9 renal transplants with evidence of interstitial rejection by biopsy showed an obliteration or reversal of diastolic flow. MR imaging was less specific in identifying allograft rejection. There were false positive results in normal renal transplants, allografts with acute tubular necrosis and after rejection therapy. With regard to cost, accessibility and specificity, Duplex sonography is the method of choice for the evaluation of renal allografts. (orig.) [de

  10. Functional MR imaging of the liver; Funktionelle MR-Tomographie der Leber

    Energy Technology Data Exchange (ETDEWEB)

    Wibmer, A.; Nolz, R.; Ba-Ssalamah, A. [Medizinische Universitaet Wien, Allgemeines Krankenhaus der Stadt Wien, Universitaetsklinik fuer Radiodiagnostik und Nuklearmedizin, Wien (Austria); Trauner, M. [Medizinische Universitaet Wien, Universitaetsklinik fuer Innere Medizin III, Klinische Abteilung fuer Gastroenterologie und Hepatologie, Wien (Austria)

    2015-12-15

    The diagnostics of diffuse liver disease traditionally rely on liver biopsies and histopathological analysis of tissue specimens. However, a liver biopsy is invasive and carries some non-negligible risks, especially for patients with decreased liver function and those requiring repeated follow-up examinations. Over the last decades, magnetic resonance imaging (MRI) has developed into a valuable tool for the non-invasive characterization of focal liver lesions and diseases of the bile ducts. Recently, several MRI methods have been developed and clinically evaluated that also allow the diagnostics and staging of diffuse liver diseases, e. g. non-alcoholic fatty liver disease, hepatitis, hepatic fibrosis, liver cirrhosis, hemochromatosis and hemosiderosis. The sequelae of diffuse liver diseases, such as a decreased liver functional reserve or portal hypertension, can also be detected and quantified by modern MRI methods. This article provides the reader with the basic principles of functional MRI of the liver and discusses the importance in a clinical context. (orig.) [German] Die Diagnostik diffuser Lebererkrankungen stuetzt sich klassisch auf die Leberbiopsie und deren histopathologische Analyse. Dieses Verfahren ist allerdings fuer die Patienten unangenehm und schmerzhaft, birgt v. a. bei Patienten mit Lebererkrankungen ein gewisses Risiko und eignet sich daher nur sehr eingeschraenkt zur Verlaufskontrolle bei chronischen Erkrankungen. Die Magnetresonanztomographie (MRT) der Leber nimmt schon jetzt eine zentrale Stellung in der Diagnostik von Raumforderungen der Leber und von Erkrankungen der Gallenwege ein. Darueber hinaus bietet dieses nichtinvasive Verfahren Moeglichkeiten, diffuse Erkrankungen des Leberparenchyms zu diagnostizieren und ihren Schweregrad abzuschaetzen, z. B. bei nichtalkoholischer Leberverfettung, Hepatitis, Leberfibrose, Zirrhose, Haemochromatose und Siderose und anderen. Folgen einer parenchymatoesen Lebererkrankung, wie die portale

  11. 3 T MR tomography of the brachial plexus: Structural and microstructural evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Mallouhi, Ammar, E-mail: Ammar.Mallouhi@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Marik, Wolfgang, E-mail: Wolfgang.Marik@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Prayer, Daniela, E-mail: Daniela.Prayer@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz, E-mail: Franz.Kainberger@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Bodner, Gerd, E-mail: Gerd.Bodner@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kasprian, Gregor, E-mail: Gregor.Kasprian@meduniwien.ac.at [Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2012-09-15

    Magnetic resonance (MR) neurography comprises an evolving group of techniques with the potential to allow optimal noninvasive evaluation of many abnormalities of the brachial plexus. MR neurography is clinically useful in the evaluation of suspected brachial plexus traumatic injuries, intrinsic and extrinsic tumors, and post-radiogenic inflammation, and can be particularly beneficial in pediatric patients with obstetric trauma to the brachial plexus. The most common MR neurographic techniques for displaying the brachial plexus can be divided into two categories: structural MR neurography; and microstructural MR neurography. Structural MR neurography uses mainly the STIR sequence to image the nerves of the brachial plexus, can be performed in 2D or 3D mode, and the 2D sequence can be repeated in different planes. Microstructural MR neurography depends on the diffusion tensor imaging that provides quantitative information about the degree and direction of water diffusion within the nerves of the brachial plexus, as well as on tractography to visualize the white matter tracts and to characterize their integrity. The successful evaluation of the brachial plexus requires the implementation of appropriate techniques and familiarity with the pathologies that might involve the brachial plexus.

  12. Quantification of absolute myocardial perfusion at rest and during exercise with positron emission tomography after human cardiac transplantation

    International Nuclear Information System (INIS)

    Krivokapich, J.; Stevenson, L.W.; Kobashigawa, J.; Huang, S.C.; Schelbert, H.R.

    1991-01-01

    The maximal exercise capacity of cardiac transplant recipients is reduced compared with that of normal subjects. To determine if this reduced exercise capacity is related to inadequate myocardial perfusion during exercise, myocardial perfusion was measured noninvasively with use of positron emission tomography and nitrogen (N)-13 ammonia. Twelve transplant recipients with no angiographic evidence of accelerated coronary atherosclerosis were studied. Serial N-13 ammonia imaging was performed at rest and during supine bicycle exercise. The results were compared with those from 10 normal volunteers with a low probability of having cardiac disease. A two-compartment kinetic model for estimating myocardial perfusion was applied to the data. Transplant recipients achieved a significant lower exercise work load than did the volunteers (42 ± 16 vs. 128 ± 22 W), but a higher venous lactate concentration (31.3 ± 14.9 vs. 13.7 ± 4.1 mg/100 ml). Despite the difference in exercise work load, there was no significant difference in the cardiac work achieved by transplant recipients and normal subjects as evidenced by similar rate-pressure products of 24,000 ± 3,400 versus 21,300 ± 2,800 betas/min per mm Hg, respectively. In addition, myocardial blood flow during exercise was not significantly different between the two groups (1.70 ± 0.60 vs. 1.56 ± 0.71 ml/min per g, respectively). This study demonstrates that the myocardial flow response to the physiologic stress of exercise is appropriate in transplant recipients and does not appear to explain the decreased exercise capacity in these patients

  13. Precision of MR-guided needle placement. Experimental results; Praezision der Lokalisierbarkeit einer Punktionsnadel in der MRT. Experimentelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Langen, H.J. [Roentgenabteilung der Missionsaerztlichen Klinik Wuerzburg (Germany); Stuetzer, H. [Inst. fuer Medizinische Statistik, Informatik und Epidemiologie der Univ. zu Koeln (Germany); Kugel, H.; Krug, B.; Hesselmann, V.; Schulte, O.; Walter, C.; Landwehr, P. [Inst. und Poliklinik fuer Radiologische Diagnostik der Univ. zu Koeln (Germany)

    2000-11-01

    -Geraet mit Turbo-Spin-Echo (TSE)- und Gradienten-Echo (FFE)-Sequenzen von 20 s bzw. 40 s Dauer in 34 unterschiedlichen Orientierungen der Nadel zu B{sub 0} Frequenzkodier- und Schichtselektionsgradienten dargestellt. 4 in der Beurteilung von Nadelartefakten unerfahrene Untersucher schaetzten unabhaengig voneinander die Positionen der Nadelspitze anhand der Artefakte ab. Die Nadelpositionen wurden vor und nach einer 15minuetigen Einweisung bestimmt, in der anhand von hochaufloesenden MR-Bildern Groesse und Form der Artfakte erklaert wurden, die bei den 12 moeglichen Kombinationen von parallelen oder rechtwinkligen Anordnungen der Nadeln zu B{sub 0} und zum Frequenzkodiergradienten auftreten. Die vor und nach der Einweisung bestimmten Positionen wurden mit den tatsaechlichen Nadelpositionen verglichen. Ergebnisse: Die Laenge der Nadel wurde in den TSE-Bildem im Mittel um 1,8{+-}2,3 mm, in den FFE-Bildern um 2,5{+-}1,2 mm ueberschaetzt. Nach der Uebung nahm der Fehler signifikant auf 0,2{+-}1,8 mm fuer die TSE-Bilder und auf 1,0{+-}1,8 mm fuer die FFE-Bilder ab. Die Lokalisation der Nadelspitze gelang in den TSE-Sequenzen im Mittel mit einer hoeheren Praezision. Schlussfolgerung: Bei MR-gesteuerter Biopsie unter Verwendung von FFE- und TSE-Sequenzen kann die Nadelposition praeziser bestimmt werden, wenn der Untersucher mit den Artefaktformen vertraut ist, die bei den 12 moeglichen rechtwinkligen oder parallelen Orientierungen der Nadel zu B{sub 0} und Frequenzkodiergradienten entstehen. (orig.)

  14. Feasibility of Computed Tomography-Guided Methods for Spatial Normalization of Dopamine Transporter Positron Emission Tomography Image.

    Science.gov (United States)

    Kim, Jin Su; Cho, Hanna; Choi, Jae Yong; Lee, Seung Ha; Ryu, Young Hoon; Lyoo, Chul Hyoung; Lee, Myung Sik

    2015-01-01

    Spatial normalization is a prerequisite step for analyzing positron emission tomography (PET) images both by using volume-of-interest (VOI) template and voxel-based analysis. Magnetic resonance (MR) or ligand-specific PET templates are currently used for spatial normalization of PET images. We used computed tomography (CT) images acquired with PET/CT scanner for the spatial normalization for [18F]-N-3-fluoropropyl-2-betacarboxymethoxy-3-beta-(4-iodophenyl) nortropane (FP-CIT) PET images and compared target-to-cerebellar standardized uptake value ratio (SUVR) values with those obtained from MR- or PET-guided spatial normalization method in healthy controls and patients with Parkinson's disease (PD). We included 71 healthy controls and 56 patients with PD who underwent [18F]-FP-CIT PET scans with a PET/CT scanner and T1-weighted MR scans. Spatial normalization of MR images was done with a conventional spatial normalization tool (cvMR) and with DARTEL toolbox (dtMR) in statistical parametric mapping software. The CT images were modified in two ways, skull-stripping (ssCT) and intensity transformation (itCT). We normalized PET images with cvMR-, dtMR-, ssCT-, itCT-, and PET-guided methods by using specific templates for each modality and measured striatal SUVR with a VOI template. The SUVR values measured with FreeSurfer-generated VOIs (FSVOI) overlaid on original PET images were also used as a gold standard for comparison. The SUVR values derived from all four structure-guided spatial normalization methods were highly correlated with those measured with FSVOI (P normalization methods provided reliable striatal SUVR values comparable to those obtained with MR-guided methods. CT-guided methods can be useful for analyzing dopamine transporter PET images when MR images are unavailable.

  15. Bimodal MR-PET agent for quantitative pH imaging

    Science.gov (United States)

    Frullano, Luca; Catana, Ciprian; Benner, Thomas; Sherry, A. Dean; Caravan, Peter

    2010-01-01

    Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on relaxivity and agent concentration – two unknowns. A bimodal approach, incorporating a positron emitter, solves this problem. Simultaneous positron emission tomography (PET) and MR imaging with the biomodal, pH-responsive MR-PET agent GdDOTA-4AMP-F allows direct determination of both concentration (PET) and T1 (MRI), and hence pH. PMID:20191650

  16. Technique of proton and phosphorous MR spectroscopy; Technik der Protonen- und Phosphor-MR-Spektroskopie

    Energy Technology Data Exchange (ETDEWEB)

    Backens, M. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2017-06-15

    Magnetic resonance spectroscopy (MRS) is an important non-invasive method that can reveal the concentration and spatial distribution of particular biochemically relevant tissue metabolites. Proton MRS is routinely applicable in the clinical setting providing good quality results even with a moderate magnetic field strength of 1.5 T. Relative values of metabolite concentrations are mostly used for the assessment of metabolic disorders. Absolute quantification of metabolites can be achieved by means of internal or external reference scans. Phosphorous MRS extends the range of detectable molecules to energy and cell membrane metabolism. The lower detection limit of metabolite concentrations is in the range of some mmol/kg. Depending on the magnetic field strength, MRS enables a spatial resolution of a few milliliters. The use of phosphorous MRS is considerably limited because higher field strengths of at least 3.0 T and additional expensive hardware for signal processing are required. (orig.) [German] Die MR-Spektroskopie (MRS) ist eine wichtige nichtinvasive Untersuchungsmethode, die Konzentration und raeumliche Verteilung einiger biochemisch relevanter Metaboliten im Gewebe ermitteln kann. Die Protonenspektroskopie ist klinisch etabliert, in der Routine einfach durchfuehrbar und liefert bereits bei einer Magnetfeldstaerke von 1,5 T qualitativ gute Ergebnisse. Fuer die Beurteilung von Stoffwechselveraenderungen werden Metabolitenkonzentrationen meist als Relativwerte angegeben. Mithilfe interner oder externer Referenzmessungen sind auch absolute Metabolitenkonzentrationen berechenbar. Die Phosphorspektroskopie erweitert den Bereich der detektierbaren Molekuele auf den Energie- und Zellmembranstoffwechsel. Die minimale nachweisbare Metabolitenkonzentration liegt bei einigen mmol/kg. Abhaengig von der Magnetfeldstaerke ist eine raeumliche Aufloesung der MRS von wenigen Millilitern erreichbar. Der Einsatz der Phosphor-MRS wird dadurch erheblich eingeschraenkt, dass sie

  17. A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner

    International Nuclear Information System (INIS)

    Slates, R.B.; Farahani, K.; Marsden, P.K.; Taylor, J.; Summers, P.E.; Williams, S.; Beech, J.

    1999-01-01

    We have assessed the possibility of artefacts that can arise in attempting to perform simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) using a small prototype MR compatible PET scanner (McPET). In these experiments, we examine MR images for any major artefacts or loss in image quality due to inhomogeneities in the magnetic field, radiofrequency interference or susceptibility effects caused by operation of the PET system inside the MR scanner. In addition, possible artefacts in the PET images caused by the static and time-varying magnetic fields or radiofrequency interference from the MR system were investigated. Biological tissue and a T 2 -weighted spin echo sequence were used to examine susceptibility artefacts due to components of the McPET scanner (scintillator, optical fibres) situated in the MR field of view. A range of commonly used MR pulse sequences was studied while acquiring PET data to look for possible artefacts in either the PET or MR images. Other than a small loss in signal-to-noise using gradient echo sequences, there was no significant interaction between the two imaging systems. Simultaneous PET and MR imaging of simple phantoms was also carried out in different MR systems with field strengths ranging from 0.2 to 4.7 T. The results of these studies demonstrate that it is possible to acquire PET and MR images simultaneously, without any significant artefacts or loss in image quality, using our prototype MR compatible PET scanner. (author)

  18. MR imaging, proton MR spectroscopy, ultrasonographic, histologic findings in patients with chronic lymphedema.

    Science.gov (United States)

    Fumiere, E; Leduc, O; Fourcade, S; Becker, C; Garbar, C; Demeure, R; Wilputte, F; Leduc, A; Delcour, C

    2007-12-01

    Lymphedema is a progressive disease with multiple alterations occurring in the dermis. We undertook this study using high-frequency ultrasonography (US), magnetic resonance imaging, proton MR spectroscopy and histology to examine structural changes occurring in the subcutaneous tissue and precisely describe the nature of intralobular changes in chronic lymphedema. Four cutaneous and subcutaneous tissue biopsies from patients with chronic lymphedema during lymphonodal transplantation were studied. We performed US with a 13.5 MHz transducer, TSE T1 and TSE T2 magnetic resonance images with and without fat-suppression, MR Chemical Shift Imaging Spectroscopy and histological evaluation on these biopsies. We found that normal subcutaneous septa are seen as hyperechogenic lines in US and hyposignal lines in MRI and that hyperechogenic subcutis in US can be due to interlobular and intralobular water accumulation and/or to interlobular and intralobular fibrosis. Our study also confirms the usefulness of MR spectroscopy to assess water or fat content of soft tissue. Thus, multiple imaging modalities may be necessary to precisely delineate the nature of tissue alterations in chronic lymphedema.

  19. Diagnostic imaging to select the candidates to orthotopic transplantation: Experience in a general hospital

    International Nuclear Information System (INIS)

    Pozzato, Carlo; Baldini, Umberto; Gattoni, Filippo; Raiteri, Riccardo; Lazzerini, Francesco; Uslenghi, Carlo Matteo; Mevoli, Alessandra

    1997-01-01

    The authors report the experience of our general hospital in selecting the patients for orthotopic liver transplantation (OLT). The accuracy of duplex Doppler and color flow Doppler for portal and/or mesenteric vein thrombosis was evaluated by correlation with resected livers, computerized tomography and angiographic findings. Pathologic examinations diagnosed HCC in 5/20 transplant recipients: 2 lesions were found in 2 resected specimens (total hepatectomy) and 1 lesion was found in 3 cases. The sensitivity of US, plain and dynamic computerized tomography in identifying HCC patients was 20%; US and computerized tomography specificity rates were 100% and 87%, respectively. CTAP sensitivity was 75% and the sensitivity of Lipiodol computerized tomography and angiography was 100%. Therefore, in our series, US was poorly sensitivity in the detection of liver cancers, which may depend on the small number of patients, lesion size and the radiologists ignoring clinical and laboratory data on purpose. Nevertheless, the patients with a single HCC not exceeding 5 cm in diameter or with no more than 3 tumors, none of them exceeding 3 cm in diameter, are generally considered eligible for transplantation: therefore, our patients chosen for OLT on the basis of US and computerized tomography findings were actually eligible for transplantation in spite of US and computerized tomography false negative results. In conclusion, considering also the long stand-by list for OLT, the first selection of transplant candidates could be performed with US and color flow Doppler, plain and dynamic computerized tomography. The patients who are not ruled out as candidates for OLT on the basis of the findings of these imaging techniques and of clinical and laboratory findings are submitted to no further examination and referred to the transplantation unit. Otherwise, if conventional and color flow Doppler US and conventional computerized tomography are not enough to exclude a patient from OLT, the

  20. MR-guided pain therapy: principles and clinical applications; MR-gesteuerte Schmerztherapie: Prinzipien und klinische Applikationen

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J.; Pereira, P.L. [Diagnostische Radiologie, Eberhard-Karls-Universitaet, Tuebingen (Germany)

    2007-09-15

    X-ray fluoroscopy and computed tomography are frequently used to perform percutaneous interventions in pain therapy. The development of MR-compatible therapy needles now allows these interventions to be performed under MR imaging guidance. MR-guided interventions may be performed using most clinical MR scanners; however, systems with an open configuration are advantageous. Multiplanar pre- and intra-procedural MR imaging provides the interventionalist with essential information, such as evaluation of anatomy and pathology, as well as the planning of the procedure and monitoring of fluid distribution without the use of contrast agents. With the use of non-ionizing radiation, interventional MR imaging is especially suited for the treatment of children and young adults as well as for serial injection therapy. For spinal MR interventions, passive needle visualization is an easily achievable and reliable method. The resulting needle artifact is influenced by several factors such as the alloy of the needle, the strength of the static magnetic field, the sequence type, the spatial orientation of the therapy needle as well as the echo time and may further be optimized during the intervention by alteration of the last three factors. Fast acquisition techniques and image processing allow for continuous, near real-time MR imaging (so-called MR fluoroscopy) and interactive needle navigations, comparable to X-ray fluoroscopy and CT fluoroscopy. The purpose of this review is to illustrate and discuss general concepts of interventional MR imaging. A spectrum of interventional MR imaging procedures in spinal pain therapy is described and illustrated, including procedures such as lumbar facet joint injections, sacroiliac joint injections, lumbar spinal nerve root infiltrations and drug delivery to the lumbar sympathetic chain. (orig.)

  1. Anatomy of the fingers in MR imaging using a high resolution surface coil; Die Anatomie der Finger in der MRT unter Anwendung einer Hochaufloesungsspule

    Energy Technology Data Exchange (ETDEWEB)

    Maeurer, J. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Mueller, H.F. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Lemke, A.J. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Requardt, R. [Siemens AG, Erlangen (Germany); Stein, I. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Langer, R. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)

    1994-12-31

    MR-images of the fingers of twenty healthy volunteers were obtained at a 1,5-T whole-body system with a high resolution coil. Additionally, the fingers of two formalin-fixed anatomical specismen were imaged, fronzen and then subsequently sectioned for anatomic correlation. Measurements were recorded with a slice thickness of 2 mm. A 256x256 matrix and a 2,5 cam fiel of view (FOV) were used resulting in a pixel size of 0,01 mm{sup 2}. Based on the excellent depiction of anatomic detail and contrast resolution high resolution MRI of the fingers enabled identification of osseous and cartilaginous structures, as well as delineation of tendons, ligaments blood-vessels and dermal layers. (orig.) [Deutsch] An einem 1,5-T-Ganzkoerpertomographen wurden die Finger von 20 gesunden Probanden mit einer Hochaufloesungsspule zur Darstellung der Anatomie untersucht. Zum Vergleich erfolgte die Abbildung der anatomischen Strukturen an zwei formol- und alkoholfixierten Leichepraeparaten der Hand mittels MRT. Im Anschluss wurden die untersuchten Regionen am tiefgefrorenen Praeparat mit einer Bandsaege nachgeschnitten. Die MR-Messungen wurden mit einer Schichtdicke von 3 mm, einem Field of View (FOV) von 25 mm und einer Matrix von 256x256 Pixel durchgefuehrt. Die daraus resultierende Pixelgroesse betrug 0,01 mm{sup 2}. Der Weichteilkontrast und die hohe Ortsaufloesung ermoeglichten die Identifikation von Knochen- und Knorpelstrukturen sowie die Abgrenzung von Sehnen, Baendern, Blutgefaessen und Hautschichten. (orig.)

  2. Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT

    NARCIS (Netherlands)

    M. Oudkerk (Matthijs); C.G. Torres; B. Song; M. Konig; J. Grimm; J. Fernandez-Cuadrado; B. op de Beeck; M. Marquardt; P. van Dijk (Pieter); J.C. de Groot (Jan Cees)

    2002-01-01

    textabstractPURPOSE: To evaluate whether mangafodipir trisodium (Mn-DPDP)-enhanced magnetic resonance (MR) imaging surpasses dual-phase spiral computed tomography (CT) in differentiating focal liver lesions. MATERIALS AND METHODS: One hundred forty-five patients who had or were

  3. Post transplant urinary tract infection in Autosomal dominant polycystic kidney disease a perpetual diagnostic dilema - 18-fluorodeoxyglucose - Positron emission computerized tomography - A valuable tool

    International Nuclear Information System (INIS)

    Sainaresh, VV; Jain, SH; Patel, HV; Shah, PR; Vanikar, AV; Trivedi, HL

    2011-01-01

    Urinary tract infection (UTI) is the most common infection contracted by renal allograft recipients. In patients of autosomal dominant polycystic kidney disease (ADPKD), cyst infection presents a complex diagnostic and therapeutic challenge especially in the post transplant period. Accurate diagnosis forms the cornerstone in salvaging the graft from potentially catastrophic outcome. We describe a case of xanthogranulomatous pyelonephritis (XPN) in the native kidney in a patient of post transplant ADPKD which presented as frequently relapsing UTI with graft dysfunction where in accurate diagnosis was made possible with the aid of 18-fluorodeoxyglucose (FDG) - Positron emission computerized tomography (PET/CT)

  4. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Mustafa Demir; Türkay Toklu; Mohammad Abuqbeitah; Hüseyin Çetin; H. Sezer Sezgin; Nami Yeyin; Kerim Sönmezoğlu

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated...

  5. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests

    OpenAIRE

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H. Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-01-01

    Objective: The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. Methods: According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated asp...

  6. Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.

    Science.gov (United States)

    Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B

    2018-02-01

    Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared

  7. The use of MR in cardiological diagnostics

    International Nuclear Information System (INIS)

    Smith, Hans-Joergen

    2004-01-01

    Image diagnostics is playing an important role in cardiology, and magnetic resonance tomography (MR) is one of many methods used in examinations of the heart. Based on studies of the literature and his own experience the author surveys the potential of MR in today's and tomorrow's diagnostics of heart diseases. Among the image diagnostic methods MR is the one that can give the most extensive information about the heart's anatomy and function. In a non-invasive way and without the use of ionizing radiation, MR can represent the anatomy in selectable planes, visualize and quantify the heart's pumping function and functioning of the cardiac valves, and give detailed information about the regional contractility, blood flow and viability of myocard. MR is capable of giving important and to some extent unique contributions to heart diseases, both congenital and contracted heart disease. Because of failing availability and competence MR is still little used in cardiological diagnostics, but the method undoubtedly has the potential to play a very important role in the future

  8. Simultaneous PET-MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET

    International Nuclear Information System (INIS)

    Tsoumpas, C.; Mackewn, J.E.; Halsted, P.; King, A.P.; Buerger, C.; Totman, J.J.; Schaeffter, T.; Marsden, P.K.

    2010-01-01

    Positron emission tomography (PET) provides an accurate measurement of radiotracer concentration in vivo, but performance can be limited by subject motion which degrades spatial resolution and quantitative accuracy. This effect may become a limiting factor for PET studies in the body as PET scanner technology improves. In this work, we propose a new approach to address this problem by employing motion information from images measured simultaneously using a magnetic resonance (MR) scanner. The approach is demonstrated using an MR-compatible PET scanner and PET-MR acquisition with a purpose-designed phantom capable of non-rigid deformations. Measured, simultaneously acquired MR data were used to correct for motion in PET, and results were compared with those obtained using motion information from PET images alone. Motion artefacts were significantly reduced and the PET image quality and quantification was significantly improved by the use of MR motion fields, whilst the use of PET-only motion information was less successful. Combined PET-MR acquisitions potentially allow PET motion compensation in whole-body acquisitions without prolonging PET acquisition time or increasing radiation dose. This, to the best of our knowledge, is the first study to demonstrate that simultaneously acquired MR data can be used to estimate and correct for the effects of non-rigid motion in PET. (author)

  9. Facial transplantation in a blind patient: psychologic, marital, and family outcomes at 15 months follow-up.

    Science.gov (United States)

    Lemmens, Gilbert M D; Poppe, Carine; Hendrickx, Hannelore; Roche, Nathalie A; Peeters, Patrick C; Vermeersch, Hubert F; Rogiers, Xavier; Lierde, Kristiane Van; Blondeel, Phillip N

    2015-01-01

    Quality of life has frequently been reported to improve after vascularized composite allotransplantation of the face. However, psychosocial functioning of the partner or of particular patient groups such as blind patients are until now less well investigated. The aim of this study is to investigate psychologic, marital, and family functioning of a blind 54-year-old patient, Mr. A, and his partner after facial transplantation. Depressive and anxiety symptoms, hopelessness, personality, coping, resilience, illness cognitions, marital support, dyadic adjustment, family functioning, and quality of life of Mr. A and his partner were assessed before and after facial transplantation and at 15 months follow-up. Reliable change index (RCI) was further calculated to evaluate the magnitude of change. Most psychologic, marital, and family scores of both Mr. A and his partner were within a normative and healthy range before and after transplant and at 15 months follow-up. Resilience (RCI: 3.6), affective responsiveness (RCI: -3.6), and disease benefits (RCI: 2.6) of Mr. A further improved at 15 months follow-up whereas the physical quality of life (RCI: -14.8) strongly decreased. Only marital support (RCI: -2.1) and depth (RCI: -2.0) of the partner decreased at 15 months. The results of this study point to positive psychosocial outcomes in a blind patient after facial transplantation. Further, they may underscore the importance of good psychosocial functioning before transplantation of both partners and of their involvement in psychologic and psychiatric treatment. Therapeutic, V. Copyright © 2015 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  10. Cellular MR Imaging

    Directory of Open Access Journals (Sweden)

    Michel Modo

    2005-07-01

    Full Text Available Cellular MR imaging is a young field that aims to visualize targeted cells in living organisms. In order to provide a different signal intensity of the targeted cell, they are either labeled with MR contrast agents in vivo or prelabeled in vitro. Either (ultrasmall superparamagnetic iron oxide [(USPIO] particles or (polymeric paramagnetic chelates can be used for this purpose. For in vivo cellular labeling, Gd3+- and Mn2+- chelates have mainly been used for targeted hepatobiliary imaging, and (USPIO-based cellular imaging has been focused on imaging of macrophage activity. Several of these magneto-pharmaceuticals have been FDA-approved or are in late-phase clinical trials. As for prelabeling of cells in vitro, a challenge has been to induce a sufficient uptake of contrast agents into nonphagocytic cells, without affecting normal cellular function. It appears that this issue has now largely been resolved, leading to an active research on monitoring the cellular biodistribution in vivo following transplantation or transfusion of these cells, including cell migration and trafficking. New applications of cellular MR imaging will be directed, for instance, towards our understanding of hematopoietic (immune cell trafficking and of novel guided (stem cell-based therapies aimed to be translated to the clinic in the future.

  11. Gadoxetic acid-enhanced magnetic resonance imaging characteristics of hepatocellular carcinoma occurring in liver transplants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mimi [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Hanyang University of Hospital, Department of Radiology, Seoul (Korea, Republic of); Kang, Tae Wook; Jeong, Woo Kyoung; Kim, Young Kon; Kim, Seong Hyun [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Jong Man [Sungkyunkwan University School of Medicine, Department of Surgery, Samsung Medical Center, Seoul (Korea, Republic of); Sinn, Dong Hyun [Sungkyunkwan University School of Medicine, Division of hepatology, Department of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Min-Ji; Jung, Sin-ho [Samsung Medical Center, Biostatics and Clinical Epidemiology Center, Seoul (Korea, Republic of)

    2017-08-15

    Characteristics of hepatocellular carcinoma (HCC) on magnetic resonance (MR) images were compared in patients who did or did not undergo liver transplantation (LT), and we evaluated the relationship of these findings with overall survival (OS) and time-to-tumour recurrence (TTR) after transplantation. The enhancement pattern of gadoxetic acid-enhanced MR images of 25 patients with recurrent HCCs (LT group) and 25 surgically confirmed HCC patients in the non-transplanted (control) group were compared. Typical enhancement was defined as 1) arterial enhancement and delayed wash-out and 2) absence of typical features of cholangiocarcinoma consisting of arterial rim enhancement and target appearance on hepatobiliary phase images. OS and TTR were analyzed in the LT group according to these patterns using the log-rank test. HCCs in the LT group significantly more often had an atypical enhancement pattern (16/25, 64.0%) than those in the control group (5/25, 20.0%; p = 0.004). However, OS and TTR did not differ significantly according to these enhancement patterns of recurrent HCC (p > 0.05). Although enhancement patterns of recurrent HCC in transplanted liver did not affect OS and TTR, these HCCs that arise after LT frequently revealed atypical enhancement on gadoxetic acid-enhanced MR imaging. (orig.)

  12. Gadoxetic acid-enhanced magnetic resonance imaging characteristics of hepatocellular carcinoma occurring in liver transplants

    International Nuclear Information System (INIS)

    Kim, Mimi; Kang, Tae Wook; Jeong, Woo Kyoung; Kim, Young Kon; Kim, Seong Hyun; Kim, Jong Man; Sinn, Dong Hyun; Kim, Min-Ji; Jung, Sin-ho

    2017-01-01

    Characteristics of hepatocellular carcinoma (HCC) on magnetic resonance (MR) images were compared in patients who did or did not undergo liver transplantation (LT), and we evaluated the relationship of these findings with overall survival (OS) and time-to-tumour recurrence (TTR) after transplantation. The enhancement pattern of gadoxetic acid-enhanced MR images of 25 patients with recurrent HCCs (LT group) and 25 surgically confirmed HCC patients in the non-transplanted (control) group were compared. Typical enhancement was defined as 1) arterial enhancement and delayed wash-out and 2) absence of typical features of cholangiocarcinoma consisting of arterial rim enhancement and target appearance on hepatobiliary phase images. OS and TTR were analyzed in the LT group according to these patterns using the log-rank test. HCCs in the LT group significantly more often had an atypical enhancement pattern (16/25, 64.0%) than those in the control group (5/25, 20.0%; p = 0.004). However, OS and TTR did not differ significantly according to these enhancement patterns of recurrent HCC (p > 0.05). Although enhancement patterns of recurrent HCC in transplanted liver did not affect OS and TTR, these HCCs that arise after LT frequently revealed atypical enhancement on gadoxetic acid-enhanced MR imaging. (orig.)

  13. Diffusion-weighted MR-imaging for the detection of pulmonary nodules at 1.5 Tesla: intraindividual comparison with multidetector computed tomography

    International Nuclear Information System (INIS)

    Regier, Marc; Schwarz, Dorothee; Henes, Frank Oliver; Groth, Michael; Begemann, Philipp G.C.; Adam, Gerhard; Kooijman, Hendrik

    2011-01-01

    To investigate the feasibility of diffusion-weighted imaging (DWI) MRI for detecting pulmonary nodules at 1.5 Tesla in comparison with standard multidetector computed tomography (MDCT). Twenty patients with disseminated cancer disease in which MDCT had assured the presence of at least one pulmonary nodule were examined using a respiratory-gated DWI MR-sequence. Grey scale inverted source images and coronal maximum intensity projection (MIP) images were consensually analysed by two experienced radiologists. Size and location of any nodule detected were assessed. Additionally, the readers evaluated each hemithorax for the presence of at least one nodule and applied a four-point conspicuity scale (1-hemithorax definitely affected; 4-hemithorax definitely not affected). MDCT data served as reference. At MDCT, a total of 71 pulmonary noduIes was found (size 3–5 mm, n = 16; 6–9 mm, n = 22; ≥10 mm, n = 33). For the DWI MR-sequence, a sensitivity of 86.4% was calculated for nodules ranging 6–9 mm and 97% for nodules ≥10 mm. In contrast, only 43.8% of lesions ≤5 mm was detected. The separate analysis of each hemithorax for the presence of at least one pulmonary nodule revealed a specificity rate, PPV and NPV of DWI-MR of 92.3%, 96% and 80%, respectively. The presented study is the first to confirm the diagnostic potential of DWI-MR in the detection of solid lung nodules. This technique allows for the detection of nodules ≥6 mm with reasonably high sensitivity rates (>86%). The observation of false positive findings decreases the accuracy of this approach compared with MDCT.

  14. Evaluation of renal allograft rejection by Doppler sonography and MR imaging

    International Nuclear Information System (INIS)

    Steinberg, H.V.; Nelson, R.C.; Murphy, F.B.; Baumgartner, B.R.; Bourke, E.; Delaney, V.B.; Whelchel, J.B.; Bernardino, M.E.

    1986-01-01

    The authors prospectively studies the efficacy of Doppler sonography and MR imaging in evaluating renal allografts, with specific attention to transplant rejection. Based on study findings, we were unable to make a statement with respect to the appearance or accuracy of diagnosing cyclosporin toxicity or acute tubular necrosis by either modality due to concomitant rejection in the few patients so afflicted. Moreover, the ability to predict and diagnose the presence or absence of allograft rejection was not affected by different serum creatinine values. Most important, however, Doppler sonography was shown to be superior to MR imaging in evaluating for allograft rejection, as evidenced by its higher sensitivity (100% vs. 71%), specificity (88% vs. 75%), and accuracy (96% vs. 73%). Thus, because of its low cost and ease of accessibility, Doppler sonography should become the primary modality for renal transplant screening

  15. Diagnostic imaging of Klippel-Feil syndrome: conventional radiography, CT and MR imaging. Case report; Bildgebende Diagnostik des Klippel-Feil-Syndroms: Konventionelle Roentgenaufnahmen, CT und MRT. Fallbericht

    Energy Technology Data Exchange (ETDEWEB)

    Jochens, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schubeus, P. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steinkamp, H.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Menzhausen, L. [Abt. fuer Psychiatrie, Urban Krankenhaus, Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1993-12-31

    In two patients with Klippel-Feil syndrome, type II radiographic findings of the malformation are shown in the cervical spine and the craniocervical junction. Conventional X-rays of the cervical spine in the AP and lateral view and conventional tomography as well as CT of the cervical spine were obtained in both patients. One of the two patients additionally underwent MR imaging. Findings of the different imaging modalities are compared with each other. (orig.) [Deutsch] Anhand von zwei Patienten mit Klippel-Feil-Syndrom Typ II werden typische radiologische Befunde des Missbildungssyndroms im Bereich der Halswirbelsaeule und des kraniozervikalen Ueberganges dargestellt. Neben den konventionellen HWS-Roentgenaufnahmen und den konventionellen Schichtaufnahmen, wurden bei beiden Patienten ein CT der HWS und bei einem Patienten zusaetzlich ein MRT durchgefuehrt. Die Ergebnisse und Befunde der verschiedenen Untersuchungsverfahren werden einander gegenuebergestellt. (orig.)

  16. Detection of the immunologic rejection after xeno-islet transplantation: a study by MR imaging enhanced with superparamagnetic iron oxide marking CD4+ T cell antibody

    International Nuclear Information System (INIS)

    Nie Wei; Tang Yiya; Rong Pengfei; Ye Bin; Ye Zheng; Tong Qiongjuan; Wang Wei

    2008-01-01

    Objective: To evaluate the feasibility of the diagnosis of the early immunologic rejection after xeno-islet transplantation by MR imaging enhanced with superparamagnetic iron oxide (SPIO) marking CD4 + T cell antibody. Methods: Two thousand neonatal porcine islets (NPI)were transplanted under the left renal capsule of BALB/C nude mice. When the grafts could be observed by MRI, 10 7 human PBMC was intraperitoneal injected to nude mouse models to reconstitute the human immunologic system, 20 mice were reconstituted. Before and 3,7,14 days after reconstitution of human immunologic system on BALB/C nude mice, MRI imaging was performed half an hour after intravenous injection of nano-immunomagnetic beads via vena caudatis to observe the grafts' MRI signal. BALB/C nude mice were sacrificed after MRI scanning immediately, the histopathologic examination was assessed on grafts, the results were compared with MRI results. And calculate the sensitivity, specificity, Youden index number and coincidence of the MRI for immunologic rejection. Results: Grafts can be observed by MRI 3 weeks after islet cell transplantation (before immunologic rejection modeling), there is no abnormal MRI signal detected in nude mice' graft region after microbeads injected. Seven days after building of immunologic rejection model, MRI hypo-signal in graft site is shown in the T 2 WI sequence after nano-bioprober injected. Histopathologic assessments were employed on grafts in nude mice immediately (HE and immunohistochemistry staining), the results shown that there are a lot of T lymphocyts infiltrated in graft region, implying the occurrence of immunologic rejection. And the sensitivity, specificity, Youden index number and coincidence is: (72.96±0.24)%, 100%, 0.73±0.24, (88.46±0.13)% respectively. The correct Kappa between the MRI and the imunohistochemistry staining was 0.76. Conclusion: The cellular immunological rejection to xeno-islet grarts can be assessed with nano-bioprobe with anti-CD4

  17. MR demonstration of spontaneous acute epidural hematoma of the thoracic spine

    International Nuclear Information System (INIS)

    Avrahami, E.; Tadmor, R.; Feibel, M.; Itzhak, Y.; Tel Aviv Univ.; Ram, Z.; Tel Aviv Univ.

    1989-01-01

    Two patients with spontaneous epidural hematoma of the thoracic spine are presented. The magnetic resonance (MR) examination performed within the first hours following the onset of symptoms demonstrated an epidural elongated lesion impinging on the spinal cord, compatible with hematoma. In one of the patients this finding was surgically confirmed. The second patient improved under steroid treatment. The MR findings were highly suggestive of the pathological nature of the lesion. The MR examination should replace other diagnostic procedures, such as computerised tomography (CT) and myelography. (orig.)

  18. Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner

    International Nuclear Information System (INIS)

    Delso, G; Martinez-Moeller, A; Bundschuh, R A; Ziegler, S I; Ladebeck, R; Candidus, Y; Faul, D

    2010-01-01

    The combination of magnetic resonance imaging (MR) and positron emission tomography (PET) scanners can provide a powerful tool for clinical diagnosis and investigation. Among the challenges of developing a combined scanner, obtaining attenuation maps for PET reconstruction is of critical importance. This requires accounting for the presence of MR hardware in the field of view. The attenuation introduced by this hardware cannot be obtained from MR data. We propose the creation of attenuation models of MR hardware, to be registered into the MR-based attenuation map prior to PET reconstruction. Two steps were followed to assess the viability of this method. First, transmission and emission measurements were performed on MR components (RF coils and medical probes). The severity of the artifacts in the reconstructed PET images was evaluated. Secondly, a high-exposure computed tomography (CT) scan was used to obtain a model of a head coil. This model was registered into the attenuation map of PET/CT scans of a uniform phantom fitted with the coil. The resulting PET images were compared to the PET/CT reconstruction in the absence of coils. The artifacts introduced by misregistration of the model were studied. The transmission scans revealed 17% count loss due to the presence of head and neck coils in the field of view. Important sources of attenuation were found in the lock, signal cables and connectors. However, the worst source of attenuation was the casing between both coils. None of the measured medical probes introduced a significant amount of attenuation. Concerning the attenuation model of the head coil, reconstructed PET images with model-based correction were comparable to the reference PET/CT reconstruction. However, inaccuracies greater than 1-2 mm in the axial positioning of the model led to important artifacts. In conclusion, the results show that model-based attenuation correction is possible. Using a high-exposure scan to create an attenuation model of the

  19. Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction.

    Science.gov (United States)

    Attenberger, Ulrike; Catana, Ciprian; Chandarana, Hersh; Catalano, Onofrio A; Friedman, Kent; Schonberg, Stefan A; Thrall, James; Salvatore, Marco; Rosen, Bruce R; Guimaraes, Alexander R

    2015-08-01

    Simultaneous data collection for positron emission tomography and magnetic resonance imaging (PET/MR) is now a reality. While the full benefits of concurrently acquiring PET and MR data and the potential added clinical value are still being evaluated, initial studies have identified several important potential pitfalls in the interpretation of fluorodeoxyglucose (FDG) PET/MRI in oncologic whole-body imaging, the majority of which being related to the errors in the attenuation maps created from the MR data. The purpose of this article was to present such pitfalls and artifacts using case examples, describe their etiology, and discuss strategies to overcome them. Using a case-based approach, we will illustrate artifacts related to (1) Inaccurate bone tissue segmentation; (2) Inaccurate air cavities segmentation; (3) Motion-induced misregistration; (4) RF coils in the PET field of view; (5) B0 field inhomogeneity; (6) B1 field inhomogeneity; (7) Metallic implants; (8) MR contrast agents.

  20. Value of magnetic resonance mammographic at 1.5 T in the differential diagnosis of mastitis versus inflammatory carcinoma; Der Wert der MR-Mammographie in der Differentialdiagnostik von non-puerperaler Mastitis und inflammatorischem Mammakarzinom bei 1,5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Tomczak, R. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Rieber, A. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Zeitler, H. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Rilinger, N. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany); Kreienberg, R. [Klinik fuer Frauenheilkunde, Univ. Ulm (Germany); Brambs, H.J. [Klinik fuer Roentgendiagnostik, Univ. Ulm (Germany)

    1996-08-01

    Purpose: The distinction between mastitis and inflammatory breast carcinoma is an important one. Current methods of evaluation including mammography, ultrasound and clinical examination do not enable this distinction. Dynamic magnetic resonance mammography (MRM) is a study with potential in this regard. Material and methods: 12 patients, in whom clinical examination, mammography and ultrasound could not distinguish between both diseases, were reviewed retrospectively by means of MRM using a 1.5 T Siemens Magnetom SP and a circular mamma coil. We used dynamic 3-D gradient echo sequences with a duration of one minute. Results: At present MRM cannot definitely distinguish between mastitis and inflammatory carcinoma, 80% of the inflammatory carcinomas were found to enhance more than 100% in the first minute, compared to 43% for mastitis. No other differences were seen. Conclusion: MRM proved useful in the follow-up of treated mastitis to demonstrate the success of antibiotic treatment of mastitis and to diagnose a histologically unconfirmed inflammatory carcinoma by means of a different follow-up. (orig.) [Deutsch] Ziel: Weder klinische Untersuchung, Ultraschall noch Mammographie erlauben die wichtige Unterscheidung zwischen non-puerperaler Mastitis und inflammatorischem Karzinom. Die Magnetresonanzmammographie (MRM) bietet sich als zusaetzliche Untersuchungsmethode zur Differenzierung an. Patienten und Methoden: Retrospektiv wurden 12 Patientinnen, bei denen klinische Untersuchung, Mammographie und Sonographie keine endgueltige Diagnose erbracht hatten, MR-mammographisch mit einem 1,5 Tesla Siemens Magnetom SP in der zirkulaeren Mammadoppelspule untersucht. Es wurden dynamische 3-D-Gradienten-Echo-Sequenzen von einer Minute Dauer verwendet. Ergebnisse: Auch die MRM leistete keinen sicheren Beitrag zur endgueltigen Diagnose. 80% der beobachteten inflammatorischen Karzinome gegenueber 43% der Mastitiden zeigten eine Kontrastmittelanreicherung ueber 100% in der ersten

  1. Computed tomography findings of postoperative complications in lung transplantation

    International Nuclear Information System (INIS)

    Hochhegger, Bruno; Irion, Klaus Loureiro; Marchiori, Edson; Bello, Rodrigo; Moreira, Jose; Camargo, Jose Jesus; Universidade Federal do Rio de Janeiro

    2009-01-01

    Due to the increasing number and improved survival of lung transplant recipients, radiologists should be aware of the imaging features of the postoperative complications that can occur in such patients. The early treatment of complications is important for the long-term survival of lung transplant recipients. Frequently, HRCT plays a central role in the investigation of such complications. Early recognition of the signs of complications allows treatment to be initiated earlier, which improves survival. The aim of this pictorial review was to demonstrate the CT scan appearance of pulmonary complications such as reperfusion edema, acute rejection, infection, pulmonary thromboembolism, chronic rejection, bronchiolitis obliterans syndrome, cryptogenic organizing pneumonia, post transplant lymphoproliferative disorder, bronchial dehiscence and bronchial stenosis. (author)

  2. MR imaging of septic sacroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Stuerzenbecher, A.; Hamm, B.; Bollow, M. [Humboldt-Universitaet, Berlin (DD). Bereich Medizin (Charite); Braun, J. [Freie Univ. Berlin (Germany). Universitaetsklinikum Benjamin Franklin; Paris, S. [Unfallkrankenhaus Berlin (Germany). Dept. of Radiology; Biedermann, T. [Krankenhaus Berlin-Buch (Germany). II. Kinderklinik

    2000-08-01

    Objective. To investigate the diagnostic value of magnetic resonance (MR) imaging in detecting septic sacroiliitis and to determine whether the MR characteristics allow this entity to be differentiated from sacroiliitis in spondylarthropathy (SpA).Patients and design. The imaging findings of 11 patients with septic sacroiliitis were retrospectively analyzed by two experienced radiologists. Radiographic surveys of the pelvis as well as computed tomography (CT) and MR images of the sacroiliac joints were available in all cases. Seven of the patients additionally underwent a follow-up MR examination. The MR imaging protocol comprised combinations of coronal and transverse T1-weighted spin-echo (SE) or fast SE sequences, T2-weighted gradient-echo (GE) sequences and short tau inversion recovery sequence (STIR) sequences as well as dynamic contrast- enhanced T1-weighted acquisitions.Results. Three patients with a short disease history showed anterior and/or posterior subperiosteal infiltrations (''lava cleft phenomenon''), transcapsular infiltrations of juxta-articular muscle layers, which obscured the fasciae, and periarticular bone marrow edema. The eight patients with more advanced stages of sacroiliitis additionally showed abscess formation, sequestration, and erosion. At follow-up MR examination (n=7) under systemic antibiotic treatment, the morphologic characteristics showed progression (n=1), regression (n=4), unchanged findings (n=1), or a mixed response (n=1). Clinical improvement precedes resolution of the MR findings.Conclusions. Anterior and/or posterior subperiosteal infiltrations and transcapsular infiltrations of juxta-articular muscle layers were depicted in all patients. These MR imaging findings are characteristic of septic sacroiliitis and may be used to differentiate this entity from sacroiliitis in SpA. (orig.)

  3. Gadolinium-enhanced T{sub 1}-weighted MR urography versus T{sub 2}-weighted (HASTE) MR urography in children; Kontrastangehobene T{sub 1}-gewichtete MR-Urographie versus T{sub 2}-gewichtete (HASTE) MR-Urographie im Kindesalter

    Energy Technology Data Exchange (ETDEWEB)

    Staatz, G.; Nolte-Ernsting, C.C.A.; Haage, P.; Tacke, J.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Rohrmann, D. [Technische Hochschule Aachen (Germany). Urologische Klinik; Stollbrink, C. [Technische Hochschule Aachen (Germany). Kinderklinik

    2001-11-01

    Purpose: To evaluate gadolinium-enhanced T{sub 1}-weighted excretory MR urography (EMRU) versus T{sub 2}-weighted (HASTE) MR urography in children with upper urinary tract abnormalities. Patients and Methods: In a prospective study 63 children, aged from 3 weeks to 15 years, underwent MR urography in a 1.5-T scanner. Before and after an intravenous injection of 0.05 mg/kg body weight of furosemide, respiratory-triggered HASTE images were obtained for T{sub 2}-weighted MR urography. EMRU was performed subsequent to i.v. gadolinium injection with respiratory-gated, coronal 3D-gradient-echo sequences. Results: Compared to T{sub 2}-weighted (HASTE) MR urography, gadolinium-enhanced MR urography revealed a superior diagnostic accuracy in non-dilated collecting systems (horseshoe kidneys, ectopic kidneys, duplex systems, single ectopic ureters, ureteroceles). EMRU and T{sub 2}-weighted (HASTE) MRU turned out to be equivalent in the assessment of obstructed but normal functioning upper urinary tracts (UPJ obstructions, megaureters). Non-functioning dilated collecting systems and multicystic dysplastic kidneys were best visualized with use of T{sub 2}-weighted (HASTE) MR urography. Conclusion: Respiratory-gated gadolinium-enhanced T{sub 1}-weighted MRU allows accurate evaluation of most upper urinary tract abnormalities. T{sub 2}-weighted (HASTE) MRU complements GMRU in the evaluation of non-functioning renal units and cystic disease of the kidneys. (orig.) [German] Ziel: Vergleich der kontrastangehobenen T{sub 1}-gewichteten MR-Urographie mit der T{sub 2}-gewichteten (HASTE) MR-Urographie bei Kindern mit Anomalien des oberen Harntraktes. Methoden: In einer prospektiven Studie wurde bei 63 Kindern (3 Wo. - 15J.) eine MR-Urographie (MRU) in einem 1,5-Tesla-Magneten durchgefuehrt. Die T{sub 2}-gewichtete MRU erfolgte vor und nach intravenoeser Injektion von 0,05 mg/kg KG Furosemid mit atemgetriggerten HASTE-Sequenzen. Fuer die T{sub 1}-gewichtete MRU wurden nach

  4. Possible role of MRI in the follow-up of the renal transplants

    International Nuclear Information System (INIS)

    Gremo, L.; Avatenello, T.; Borre', A.; Potenzoni, F.; Colla, L.; Segolini, G.

    1988-01-01

    The authors discuss the possible role of Magnetic Resonance Imaging (MRI) in the follow-up of renal transplants. Its diagnostic accuracy is compared with Ultrasounds (US), which is considered the method of choice in postoperative monitoring of renal transplants. Thirty-two patients (transplant life ranging from 5 days to 37 months) were examined in the same day with both MRI and US. Sonographic evaluation is based on a group of signs related to renal alteration and unanimously ascertained; the identification of MR patterns of normally functioning kidney or renal rejection might give way to more extensive clinical applications of the method, with the advantages of multiplanarity and no X-ray use. MR diagnostic accuracy in the diagnosis of normally functioning transplant or renal rejection was 82.7% (vs. US: 68.9% vs. 656.25%). MRI is more sensitive in demonstrating renal pathology in transplanted kidneys, and its diagnostic accuracy is superior. Still, US must be considered the methodology of choice in instrumental research when there is a clinical suspicion of renal rejection, due to its sufficient diagnostic accuracy, to its being easy to perform in continuous follow-up, to its low cost and to the short execution time. MRI is nevertheless suggested in the follow-up of renal transplants both in questionable cases and when biopsy cannot be performed

  5. PET/MR Imaging in Vascular Disease

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Pedersen, Sune Folke; Kjær, Andreas

    2016-01-01

    For imaging of atherosclerotic disease, lumenography using computed tomography, ultrasonography, or invasive angiography is still the backbone of evaluation. However, these methods are less effective to predict the likelihood of future thromboembolic events caused by vulnerability of plaques. PET...... through data and arguments that support increased use of PET/MR imaging in atherosclerotic imaging....

  6. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters

    International Nuclear Information System (INIS)

    Adam, G.; Glowinski, A.; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-01-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212[). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF[). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [de

  7. Computer tomography, magnetic resonance imaging, and positron emission tomography or positron emission tomography/computer tomography for detection of metastatic lymph nodes in patients with ovarian cancer: A meta-analysis

    International Nuclear Information System (INIS)

    Yuan Ying; Gu Zhaoxiang; Tao Xiaofeng; Liu Shiyuan

    2012-01-01

    Objectives: To compare the diagnostic performances of computed tomography (CT), magnetic resonance (MR) imaging, and positron emission tomography (PET or PET/CT) for detection of metastatic lymph nodes in patients with ovarian cancer. Methods: Relevant studies were identified with MEDLINE and EMBASE from January 1990 to July 2010. We estimated the weighted summary sensitivities, specificities, OR (odds ratio), and summary receiver operating characteristic (sROC) curves of each imaging technique and conducted pair-wise comparisons using the two-sample Z-test. Meta-regression, subgroup analysis, and funnel plots were also performed to explain the between-study heterogeneity. Results: Eighteen eligible studies were included, with a total of 882 patients. PET or PET/CT was a more accurate modality (sensitivity, 73.2%; specificity, 96.7%; OR [odds ratio], 90.32). No significant difference was detected between CT (sensitivity, 42.6%; specificity, 95.0%; OR, 19.87) and MR imaging (sensitivity, 54.7%; specificity, 88.3%; OR, 12.38). Meta-regression analyses and subgroup analyses revealed no statistical difference. Funnel plots with marked asymmetry suggested a publication bias. Conclusion: FDG-PET or FDG-PET/CT is more accurate than CT and MR imaging in the detection of lymph node metastasis in patients with ovarian cancer.

  8. An Investigation of Methods for CT Synthesis in MR-only Radiotherapy

    DEFF Research Database (Denmark)

    Andreasen, Daniel

    In recent years, the interest in using magnetic resonance (MR) imaging in radiotherapy (RT) has increased. This is because MR has a superior soft tissue contrast compared to computed tomography (CT), which makes it a better modality for delineating the target volume (tumor) and possible organs...... at risk (OARs). In an MR/CT work-flow, independent MR and CT scans are acquired. The target and possible OARs are delineated on the MR and then transferred to CT by aligning the data using a registration. This introduces the risk of systematic registration errors especially in non-rigid body structures......, the consequence being a systematic miss of target or increased dose to healthy tissue. Radiotherapy based on MR as the only modality removes this uncertainty and simplifies the clinical work-flow. However, the information on electron density which is usually contained in the CT must now be derived from the MR...

  9. Diagnosis of post-transplant lymphoproliferative disorder in solid organ transplant recipients - BCSH and BTS Guidelines.

    Science.gov (United States)

    Parker, Anne; Bowles, Kristin; Bradley, J Andrew; Emery, Vincent; Featherstone, Carrie; Gupte, Girish; Marcus, Robert; Parameshwar, Jayan; Ramsay, Alan; Newstead, Charles

    2010-06-01

    A joint working group established by the Haemato-oncology subgroup of the British Committee for Standards in Haematology (BCSH) and the British Transplantation Society (BTS) has reviewed the available literature and made recommendations for the diagnosis and management of post-transplant lymphoproliferative disorder (PTLD) in adult recipients of solid organ transplants. This review details the risk factors predisposing to development, initial features and diagnosis. It is important that the risk of developing PTLD is considered when using post transplant immunosuppression and that the appropriate investigations are carried out when there are suspicions of the diagnosis. These must include tissue for histology and computed tomography scan to assess the extent of disease. These recommendations have been made primarily for adult patients, there have been some comments made with regard to paediatric practice.

  10. A study of MRI-guided diffuse fluorescence molecular tomography for monitoring PDT effects in pancreas cancer

    Science.gov (United States)

    Samkoe, Kimberley S.; Davis, Scott C.; Srinivasan, Subhadra; O'Hara, Julia A.; Hasan, Tayyaba; Pogue, Brian W.

    2009-06-01

    Over the last several decades little progress has been made in the therapy and treatment monitoring of pancreas adenocarcinoma, a devastating and aggressive form of cancer that has a 5-year patient survival rate of 3%. Currently, investigations for the use of interstitial Verteporfin photodynamic therapy (PDT) are being undertaken in both orthotopic xenograft mouse models and in human clinical trials. In the mouse models, magnetic resonance (MR) imaging has been used as a measure of surrogate response to Verteporfin PDT; however, MR imaging alone lacks the molecular information required to assess the metabolic function and growth rates of the tumor immediately after treatment. We propose the implementation of MR-guided fluorescence tomography in conjunction with a fluorescently labeled (IR-Dye 800 CW, LI-COR) epidermal growth factor (EGF) as a molecular measure of surrogate response. To demonstrate the effectiveness of MR-guided diffuse fluorescence tomography for molecular imaging, we have used the AsPC-1 (+EGFR) human pancreatic adenocarcinoma in an orthotopic mouse model. EGF IRDye 800CW was injected 48 hours prior to imaging. MR image sequences were collected simultaneously with the fluorescence data using a MR-coupled diffuse optical tomography system. Image reconstruction was performed multiple times with varying abdominal organ segmentation in order to obtain a optimal tomographic image. It is shown that diffuse fluorescence tomography of the orthotopic pancreas model is feasible, with consideration of confounding fluorescence signals from the multiple organs and tissues surrounding the pancreas. MR-guided diffuse fluorescence tomography will be used to monitor EGF response after photodynamic therapy. Additionally, it provide the opportunity to individualize subsequent therapies based on response to PDT as well as to evaluate the success of combination therapies, such as PDT with chemotherapy, antibody therapy or even radiation.

  11. Advances in radiographic NDI of pipe systems; Fortschritte bei der Durchstrahlungspruefung von Rohrleitungssystemen

    Energy Technology Data Exchange (ETDEWEB)

    Morgner, W. [NSQ HAUK, Ludwigshafen (Germany); Hauk, T. [NSQ HAUK, Ludwigshafen (Germany); Tschachlov, V. [NSQ HAUK, Tomsk (Russian Federation)

    1995-12-31

    The paper discusses the application of a small-sized betatron and its operational parameters, and its uses for very small angle tomography of medium-filled pipes or a thick weld. Other aspects discussed are the handling of large numbers of X-ray images by means of an X-ray manipulator, film digitalization, and data management of imaging data. (orig./MM) [Deutsch] Dieser Beitrag behandelt die Anwendung eines Kleinbetatrons und seiner Leistungsparameter, damit durchgefuehrte Durchstrahlungspruefungen an mediumgefuellten Rohren und eine an einer dicken Schweissnaht realisierte Wenigwinkeltomographie. Bezueglich der Beherrschung einer Grosszahl von Roentgenaufnahmen wird ueber einen Roentgenmanipulator, die Filmdigitalisierung und das Datenmanagement von Bilddaten berichtet. (orig./MM)

  12. First image from a combined positron emission tomography and field-cycled MRI system.

    Science.gov (United States)

    Bindseil, Geron A; Gilbert, Kyle M; Scholl, Timothy J; Handler, William B; Chronik, Blaine A

    2011-07-01

    Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI. Copyright © 2010 Wiley-Liss, Inc.

  13. Applications of cerebral MRI in neonatology; MRT bei Neugeborenen mit Verdacht auf zerebrale Stoerung

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, D. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Neuroradiologie; Kuhle, S. [Universitaetsklinik fuer Kinder- und Jugendheilkunde, Wien (Austria). Abt. fuer Neonatologie, angeborene Stoerungen und Intensivmedizin; Blaicher, W. [Abt. fuer Frauenheilkunde und Praenatale Diagnostik, Wien (Germany)

    2000-01-01

    Magnetic resonance tomography (MRT) has become the most important method in the workup of infantile cerebral complications after primary sonography. Cerebral MR examination and image interpretation during the infantile period require extensive knowledge of morphological manifestations, their pathophysiological background, and frequency. The choice of imaging parameters and image interpretation is demonstrated in infarctions and hemorrhages of the mature and immature brain. A review of the main differential diagnoses is also given. The relevance of MR spectroscopy and fetal MRI is discussed. (orig.) [German] Zur Abklaerung zerebraler Veraenderungen bei Neugeborenen hat sich die Magnetresonanztomographie (MRT) als wichtigste weiterfuehrende Methode nach der Sonographie entwickelt. Die Durchfuehrung und Auswertung der MR-Untersuchungen erfordern jedoch eine genaue Kenntnis der morphologischen Manifestation, des pathophysiologischen Hintergrunds und der Haeufigkeit bestimmter zerebraler Komplikationen in diesem Lebensalter. Resuemee: Ausgehend von zerebrovaskulaeren Erkrankungen werden diese Fragen behandelt, wobei sowohl auf die Auswahl der adaequaten Untersuchungsparameter als auch auf die Bildinterpretation und die wichtigsten Differentialdiagnosen eingegangen wird. Die Bedeutung von MR-Spektroskopie und fetaler MRT wird diskutiert. (orig.)

  14. Imaging in lung transplants: Checklist for the radiologist

    International Nuclear Information System (INIS)

    Madan, Rachna; Chansakul, Thanissara; Goldberg, Hilary J

    2014-01-01

    Post lung transplant complications can have overlapping clinical and imaging features, and hence, the time point at which they occur is a key distinguisher. Complications of lung transplantation may occur along a continuum in the immediate or longer postoperative period, including surgical and mechanical problems due to size mismatch and vascular as well as airway anastomotic complication, injuries from ischemia and reperfusion, acute and chronic rejection, pulmonary infections, and post-transplantation lymphoproliferative disorder. Life expectancy after lung transplantation has been limited primarily by chronic rejection and infection. Multiple detector computed tomography (MDCT) is critical for evaluation and early diagnosis of complications to enable selection of effective therapy and decrease morbidity and mortality among lung transplant recipients

  15. Role of MR imaging in chronic wrist pain

    Energy Technology Data Exchange (ETDEWEB)

    Zanetti, Marco; Saupe, Nadja [University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); Nagy, Ladislav [University Hospital Balgrist, Department of Orthopedic Surgery, Zurich (Switzerland)

    2007-04-15

    Magnetic resonance (MR) imaging for chronic wrist pain is challenging. Correct assessment of the triangular fibrocartilage, hyaline cartilage, ligaments, and tendons has become mandatory for comprehensive decision making in wrist surgery. The MR technique, potential and limits of MR imaging in patients with chronic wrist pain will be discussed. MR arthrography with injection of gadolinium-containing contrast material into the distal radioulnar joint is suggested for evaluation of the triangular fibrocartilage. The clinically meaningful ulnar-sided peripheral tears are otherwise hard to diagnose. The diagnostic performance of MR imaging for interosseous ligament tears varies considerably. The sensitivity for scapholunate ligament tears is consistently better than for lunotriquetral ligament tears. Gadolinium-enhanced MR imaging is considered to be the best technique for detecting established avascularity of bone, but the assessment of the MR results remains challenging. Most cases of ulnar impaction syndrome have characteristic focal signal intensity changes in the ulnar aspect of the lunate. Avascular necrosis of the lunate (Kienboeck's disease) is characterized by signal changes starting in the proximal radial aspect of the lunate. MR imaging is extremely sensitive for occult fractures. Questions arise if occult posttraumatic bone lesions seen on MR images only necessarily require the same treatment as fractures evident on plain films or computed tomography (CT) images. MR imaging and ultrasound are equally effective for detecting occult carpal ganglia. Carpe bossu (carpal boss) is a bony protuberance of a carpometacarpal joint II and III which may be associated with pain. (orig.)

  16. Role of MR imaging in chronic wrist pain

    International Nuclear Information System (INIS)

    Zanetti, Marco; Saupe, Nadja; Nagy, Ladislav

    2007-01-01

    Magnetic resonance (MR) imaging for chronic wrist pain is challenging. Correct assessment of the triangular fibrocartilage, hyaline cartilage, ligaments, and tendons has become mandatory for comprehensive decision making in wrist surgery. The MR technique, potential and limits of MR imaging in patients with chronic wrist pain will be discussed. MR arthrography with injection of gadolinium-containing contrast material into the distal radioulnar joint is suggested for evaluation of the triangular fibrocartilage. The clinically meaningful ulnar-sided peripheral tears are otherwise hard to diagnose. The diagnostic performance of MR imaging for interosseous ligament tears varies considerably. The sensitivity for scapholunate ligament tears is consistently better than for lunotriquetral ligament tears. Gadolinium-enhanced MR imaging is considered to be the best technique for detecting established avascularity of bone, but the assessment of the MR results remains challenging. Most cases of ulnar impaction syndrome have characteristic focal signal intensity changes in the ulnar aspect of the lunate. Avascular necrosis of the lunate (Kienboeck's disease) is characterized by signal changes starting in the proximal radial aspect of the lunate. MR imaging is extremely sensitive for occult fractures. Questions arise if occult posttraumatic bone lesions seen on MR images only necessarily require the same treatment as fractures evident on plain films or computed tomography (CT) images. MR imaging and ultrasound are equally effective for detecting occult carpal ganglia. Carpe bossu (carpal boss) is a bony protuberance of a carpometacarpal joint II and III which may be associated with pain. (orig.)

  17. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  18. Optical Coherence Tomography of the Aging Kidney.

    Science.gov (United States)

    Andrews, Peter M; Wang, Hsing-Wen; Guo, Hengchang; Anderson, Erik; Falola, Reuben; Chen, Yu

    2016-12-01

    The aging kidney exhibits a progressive decline in renal function with characteristic histopathologic changes and is a risk factor for renal transplant. However, the degree to which the kidney exhibits this decline depends on several factors that vary from one individual to the next. Optical coherence tomography is an evolving noninvasive imaging technology that has recently been used to evaluate acute tubular necrosis of living-human donor kidneys before their transplant. With the increasing use of kidneys from older individuals, it is important to determine whether optical coherence tomography also can distinguish the histopathology associated with aging. In this investigation, we used Munich-Wistar rats to evaluate the ability of optical coherence tomography to detect histopathologic changes associated with aging. Optical coherence tomography observations were correlated with renal function and conventional light microscopic evaluation of these same kidneys. With the onset of severe proteinuria at 10 to 12 months of age, optical coherence tomography revealed tubular necrosis/atrophy, interstitial fibrosis, tubular dilation, and glomerulosclerosis. With a further deterioration in kidney function at 16 to 18 months of age (as indicated by rising creatinine levels), optical coherence tomography revealed more extensive interstitial fibrosis and tubular atrophy, increased tubular dilation with cyst formation and more sclerotic glomeruli. The foregoing observations suggest that optical coherence tomography can be used to detect the histopathology of progressive nephropathy associated with aging.

  19. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  20. Magnetic resonance (MR) in the diagnosis of pancreatic disease

    International Nuclear Information System (INIS)

    Anacker, H.; Rupp, N.; Reiser, M.; Technische Univ. Muenchen

    1984-01-01

    New methods of examination are measured in terms of the efficiency of their predecessors. The introduction of endoscopic retrograde cholangiopancreatography (ERCP) and computerised tomography (CT) constituted a turning point in the diagnosis of pancreatic disease. In this incipient stages as a clinical diagnostic method, the question is raised whether or not there is evidence that magnetic resonance (MR) can supplement, improve upon or replace the customary methods. It must, however, be taken into account that the technical development of MR is still in progress and that clinical experience with MR in the diagnosis of pancreatic disease, as in other areas, is still insufficient. At this point it is only possible to survey the trends. (orig.)

  1. Optimized MLAA for quantitative non-TOF PET/MR of the brain

    DEFF Research Database (Denmark)

    Benoit, Didier; Ladefoged, Claes N.; Rezaei, Ahmadreza

    2016-01-01

    For quantitative tracer distribution in positron emission tomography, attenuation correction is essential. In a hybrid PET/CT system the CT images serve as a basis for generation of the attenuation map, but in PET/MR, the MR images do not have a similarly simple relationship with the attenuation...... map. Hence attenuation correction in PET/MR systems is more challenging. Typically either of two MR sequences are used: the Dixon or the ultra-short time echo (UTE) techniques. However these sequences have some well-known limitations. In this study, a reconstruction technique based on a modified...... and optimized non-TOF MLAA is proposed for PET/MR brain imaging. The idea is to tune the parameters of the MLTR applying some information from an attenuation image computed from the UTE sequences and a T1w MR image. In this MLTR algorithm, an [Formula: see text] parameter is introduced and optimized in order...

  2. Post-transplant Lymphoproliferative Disorder Arising from Renal Allograft Parenchyma: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan; Kim, Chan Kyo; Kwon, Ghee Young [Samsung Medical Center, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    2010-06-15

    Post-transplant lymphoproliferative disorder (PTLD) is a rare but serious complication that occurs in patients undergoing kidney transplantation. PTLD usually manifests as a renal hilar mass comprised of histologically B-lymphocytes. We report our experience of managing a patient with PTLD arising from renal parenchyma. Ultrasonographic and MR imaging features of this unusual PTLD suggested differentiated renal cell carcinoma arising from the renal allograft

  3. Siim Nestor soovitab : Bell Orchestre. DJ Deep ja TRL. Akrobatik ja MC Mr.Lif. Black Dice / Siim Nestor

    Index Scriptorium Estoniae

    Nestor, Siim, 1974-

    2008-01-01

    Muusikaüritustest: Kanada post-rock ansambel Bell Orchestre12. sept. Tallinnas klubis Juuksur, DJ Deep 12. sept. Tallinna Linnahalli ruumides Plektrumi klubiööl (vt. www.plektrumfestival.ee), Akrobatik ja Mr.Lif 12. sept. Tartus klubis Illusion, New Yorgi kollektiiv Black Dice 17. sept. Tallinnas Von Krahlis

  4. MR imaging of soft tissue tumors and tumor-like lesions

    Energy Technology Data Exchange (ETDEWEB)

    Laor, Tal [Department of Radiology, Cincinnati Children' s Hospital Medical Center, 3333 Burnet Avenue, 45229, Cincinnati, OH (United States)

    2004-01-01

    The evaluation of a soft tissue mass in a child should proceed with a differential diagnosis in mind, based on the clinical history, age of the child, and location of the abnormality. Small, superficial masses can be initially evaluated with sonography. More extensive or deep lesions usually require cross-sectional imaging. With the exception of myositis ossificans, magnetic resonance (MR) imaging has largely replaced the use of computed tomography. MR imaging is used to delineate the extent of a lesion, to evaluate response to therapy, and to monitor postoperative complications. There is great overlap in the MR imaging characteristics of benign and malignant lesions, making tissue sampling imperative for diagnosis. (orig.)

  5. {sup 31}P-MR spectroscopy of the brain in patients with anorexia nervosa: characteristic differences in the spectra between patients and healthy control subjects; {sup 31}P-MRS des Hirns bei Anorexia nervosa: charakteristische Unterschiede in den Spektren von Patienten und gesunden Vergleichspersonen

    Energy Technology Data Exchange (ETDEWEB)

    Rzanny, R.; Reichenbach, J.R.; Mentzel, H.J.; Pfleiderer, S.O.R.; Kaiser, W.A. [Inst. fuer Diagnostische und Interventionelle Radiologie, Klinikum der Friedrich-Schiller-Univ. Jena (Germany); Freesmeyer, D.; Klemm, S.; Gerhard, U.J.; Blanz, B. [Klinik fuer Kinder- und Jugendpsychiatrie, Klinikum der Friedrich-Schiller-Univ. Jena (Germany)

    2003-01-01

    Purpose: To investigate whether {sup 31}P-MR spectroscopy can detect reduced concentrations of high-energy phosphates, like PCr and NTP, caused by decreased metabolic activity in the brain of patients with anorexia nervosa (AN) and, furthermore, whether any impairment of the cerebral membrane metabolism can be derived from the spectra. Material and Methods: 10 female patients, age range 12 - 20 years and mean BMI (body mass index) of 14.8 {+-} 1.6 kg/m{sup 2}, with clinically diagnosed AN (ICD-10, F50.0) and 10 healthy control subjects, age range 12 - 21 years and mean BMI 19.0 {+-} 2.1 kg/m{sup 2}, without nutritional disturbances: were investigated. {sup 31}P-MR spectroscopy was performed with a 1.5 T MRI unit using single volume selection in the frontal/prefrontal region of brain. Relative metabolic concentrations were quantified by normalizing the peak areas of the metabolites with the total area of the complete phosphorous spectrum, P{sub tot}, as well as with the peak area of β-NTP. Results: Significant differences between the two groups were observed for the metabolic ratios PDE/P{sub tot}, PDE/β-NTP and {alpha}-NTP/P{sub tot} which were lower in the patient group except for {alpha}-NTP/P{sub tot}. These ratios also revealed a statistically significant correlation with the BMI (r{sub PDE/Ptot} = 0.747, r{sub PDE/β-NTP} = 0.57, r{sub {alpha}}{sub -NTP/Ptot} = -0.56; p {<=} 0.1). Reduced relative concentrations of PCr/P{sub tot}, β-NTP/P{sub tot} or Pi/P{sub tot} were not encountered. Conclusion: The lowered PDE/P{sub tot} ratio for patients with AN and its correlation with BMI suggests that decreased BMI induces compositional changes of the phospholipids in the brain, which decrease the fraction of mobile phospholipids. (orig.) [German] Problemstellung: Das Ziel dieser Studie war es zu untersuchen, ob mit Hilfe der {sup 31}P-MR-Spektroskopie ({sup 31}P-MRS) im Gehirn von Patienten mit Anorexia nervosa (AN) verringerte Konzentrationen an

  6. Pitfalls in the MR diagnosis of primary malignant bone tumors; Pitfalls in der MR-Diagnostik primaer maligner Knochentumoren

    Energy Technology Data Exchange (ETDEWEB)

    Bader, T.R. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Osteologie; Imhof, H.; Breitenseher, M.J. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria). Abt. fuer Osteologie]|[Wien Univ. (Austria). Einrichtung UOG Magnetic Resonanz; Dominkus, M. [Universitaetsklinik fuer Orthopaedie, Wien (Austria)

    1998-06-01

    MRI has gained an undisputed place in the evaluation of malignant bone tumors, not only for verifying results of conventional radiography and clarifying differential diagnoses; it has also become increasingly important for the assessment of the malignant/benign nature of the tumor, its growth rate, definition of adequate sites for biopsy, local preoperative staging, and evaluation of the response to chemotherapy. However, several pitfalls have to be observed regarding choice of technical parameters (coils, sequences, imaging planes), tissue differentiation, and tumor staging. When staging malignant tumors, critical aspects which have to be observed are tumor extension, integrity of the cortical bone, soft tissue components, infiltration of a joint or neurovascular bundle. The use of contrast agents provides important additional information but can also give rise to misinterpretations. Thus, all features of a tumor have to be observed in order to establish a final diagnosis. Particular difficulties can occur with the interpretation of MR images of osteomyelitis, osteoid osteoma, stress and insufficiency fractures, bone infarcts, myositis ossificans, hemangiomas, and aneurysmal bone cysts. (orig.) [Deutsch] Bei der Diagnostik von malignen Knochentumoren hat die MRT einen fixen Platz nicht nur in der Verifikation der Nativdiagnostik und der Differentialdiagnostik, sondern zunehmende Bedeutung bei der primaeren Beurteilung von Dignitaet und Wachstumsgeschwindigkeit, Definition einer geeigneten Biopsiestelle, beim lokoregionaeren, praeoperativen Staging und der Evaluation des Ansprechens auf Chemotherapie. Zahlreiche Pitfalls finden sich jedoch bei der Wahl der technischen Parameter (Spulen, Sequenzen, Schichtebenen), der Tumordifferenzierung und beim Staging von malignen Tumoren. Beim Staging sind die kritischen Punkte die Beurteilung von Tumorausdehnung, Integritaet der Kortikalis, Vorhandensein einer Weichteilkomponente, Infiltration eines Gelenks oder des

  7. MRI screening before stem cell transplantation - necessary?

    International Nuclear Information System (INIS)

    Zimmermann, U.; Mentzel, H.J.; Kaiser, W.A.; Wolf, J.; Fuchs, D.; Gruhn, B.; Zintl, F.

    2008-01-01

    Purpose: in the context of stem cell transplantation (SCT), we often observe neurological complications as a consequence of immune system suppression, conditioning therapy or prophylaxis and treatment of graft-versus-host disease. Furthermore, cerebral lesions in existence prior to transplantation can be found. The aim of this study was to evaluate the benefit of cerebral magnetic resonance imaging (MRI) prior to stem cell transplantation. Patients and method: cerebral MR examinations of 116 children and adolescents were performed before SCT. Patients ranged in age from 1.1 to 21.4 years (mean 12.6 years). All MR images were obtained by a 1.5 T System. The predefined short protocol included an axial T1-weighted SE sequence and a coronary T2-weighted TSE sequence. We evaluated existing cerebral lesions, the diameter of the ventricular system, and the paranasal sinuses. In the case of pathological findings, the short examination protocol was expanded. Results: in 5 of 116 children (4.3%) we observed prior to SCT findings requiring immediate treatment although the patients did not show any clinical symptoms (1 x aspergilloma, 1 x hemorrhage of vascular anomaly). An increased risk of bleeding caused by cavernoma or another vascular anomaly without hemorrhage also had to be taken into account. 32 of 116 patients (37.1%) showed atrophic lesions. In 42 children (36.2%), we observed affections of the paranasal sinuses. (orig.)

  8. A computed tomography-based spatial normalization for the analysis of [18F] fluorodeoxyglucose positron emission tomography of the brain.

    Science.gov (United States)

    Cho, Hanna; Kim, Jin Su; Choi, Jae Yong; Ryu, Young Hoon; Lyoo, Chul Hyoung

    2014-01-01

    We developed a new computed tomography (CT)-based spatial normalization method and CT template to demonstrate its usefulness in spatial normalization of positron emission tomography (PET) images with [(18)F] fluorodeoxyglucose (FDG) PET studies in healthy controls. Seventy healthy controls underwent brain CT scan (120 KeV, 180 mAs, and 3 mm of thickness) and [(18)F] FDG PET scans using a PET/CT scanner. T1-weighted magnetic resonance (MR) images were acquired for all subjects. By averaging skull-stripped and spatially-normalized MR and CT images, we created skull-stripped MR and CT templates for spatial normalization. The skull-stripped MR and CT images were spatially normalized to each structural template. PET images were spatially normalized by applying spatial transformation parameters to normalize skull-stripped MR and CT images. A conventional perfusion PET template was used for PET-based spatial normalization. Regional standardized uptake values (SUV) measured by overlaying the template volume of interest (VOI) were compared to those measured with FreeSurfer-generated VOI (FSVOI). All three spatial normalization methods underestimated regional SUV values by 0.3-20% compared to those measured with FSVOI. The CT-based method showed slightly greater underestimation bias. Regional SUV values derived from all three spatial normalization methods were correlated significantly (p normalization may be an alternative method for structure-based spatial normalization of [(18)F] FDG PET when MR imaging is unavailable. Therefore, it is useful for PET/CT studies with various radiotracers whose uptake is expected to be limited to specific brain regions or highly variable within study population.

  9. The use of computer tomography of the abdomen in differentiating post-transplant complications in patients with renal grafts using a study of clinical cases

    International Nuclear Information System (INIS)

    Borowiak, H.; Glowacki, J.; Pieta, M.; Sraga, W.; Trzeszkowska-Rotkegel, S.; Jackowska, Z.; Myga-Porosilo, J.; Legaszewski, T.; Skrzelewski, S.; Zywiec, J.

    2006-01-01

    The aim of the study was to describe the diagnostic efficiency of computer tomography in the differentiation of urgent complications after renal transplants. The most common situation which needs to be explained using imaging diagnostics is acute abdominal pain in patients with renal grafts shortly after the operation (within a few weeks) in conditions of emergency. Most of the examinations were performed without contrast enhancement to avoid possible nephrotoxicity of the contrast media following the transplantology rule. The difference in the efficiency of the two methods with or without i.v. infusion contrast is emphasized. Thirty-two CT's of 22 patients with complications after renal transplants were analyzed by comparing their clinical data. The images were compared with regard to size, parenchymal density, and homogeneity of the renal graft. Furthermore, contrast enhancement homogeneity with preservation of the cortical-medullar differentiation, width of the excretory system and the ureter, and presence of circumgraft fluid collection with a designation of its density and periorbital specify (lymphocele, abscess, or hematoma) were also considered. When possible, the lumen of the renal vessels and the state of vessel anastomosis were recorded (CT angiography and some good-quality contrast examination). Also, other pathologies in the examined region were considered as a potential cause of the acute pain (e.g. multiplanar reconstruction was performed to obtain proper images of the lumbal spine). CT of the abdomen explained clinical problems in 21 of the 22 patients (95%). Most examinations showed that the fluid collections were lymphocele, mainly small and without compression of adjoining structures, which are considered normal after transplants. Large fluid collections requiring decompression were found in 6 patients (including 2 hematoma and 1 with abscess). Causes unrelated to renal graft were found in 4 cases. Computer tomography, although it is not included

  10. MR imaging versus PET/CT for evaluation of pancreatic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Belião, Sara, E-mail: sara.beliao@clix.pt [Department of Radiology Hospital S. Francisco Xavier, Estrada do Forte do Alto do Duque, 1495-005 Lisbon (Portugal); Ferreira, Alexandra, E-mail: alexandratavaresferreira@gmail.com [Department of Radiology, Hospital D. Estefânia, Rua Jacinta Marto, 1169-045 Lisbon (Portugal); Vierasu, Irina, E-mail: Ortansa-Irina.Vierasu@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Blocklet, Didier, E-mail: dblockle@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Goldman, Serge, E-mail: petscan@ulb.ac.be [Service de Médecine Nucléaire, Route de Lennik 808, 1070 Brussels (Belgium); Metens, Thierry, E-mail: tmetens@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium); Matos, Celso, E-mail: cmatos@ulb.ac.be [Service de Radiologie – Imagerie par Resonance Magnétique, Route de Lennik 808, 1070 Brussels (Belgium)

    2012-10-15

    Purpose: To retrospectively determine the diagnostic accuracy of magnetic resonance imaging (MRI) and combined positron emission tomography/computed tomography (PET/CT) in the differential diagnosis of benign and malignant pancreatic lesions. Materials and methods: Twenty-seven patients (15 women/12 men, mean age 56.5 years) with MR imaging and PET/CT studies performed to differentiate benign and malignant pancreatic lesions were identified between October 2008 and October 2010. Both MR and PET/CT data sets were retrospectively and blindly evaluated by two independent readers (4 readers total) with different degrees of experience, using a visual five-point score system. The results were correlated with final diagnosis obtained by histopathology. Results: 17 patients had malignant diseases and 10 patients had benign diseases. Depending on the observer, the sensitivity, specificity, positive predictive value and negative predictive value of MRI varied between 88–94%, 50–80%, 75–89% and 71–89% respectively. Sensitivities, specificities, positive predictive values and negative predictive values of PET/CT were 73%, 56%, 73% and 56% respectively. The diagnostic accuracy of MR for the differential diagnosis of pancreatic lesions was 74–89%, compared with 67% for PET/CT. The weighted Cohen's kappa coefficient was 0.47 at MR and 0.53 at PET/CT. Conclusion: MRI achieved higher sensitivity and specificity in the differential diagnosis of pancreatic lesions.

  11. Chest computed tomography scores are predictive of survival in patients with cystic fibrosis awaiting lung transplantation

    DEFF Research Database (Denmark)

    Loeve, Martine; Hop, Wim C. J.; de Bruijne, Marleen

    2012-01-01

    Rationale: Up to a third of cystic fibrosis (CF) patients awaiting lung transplantation (LTX) die while waiting. Inclusion of computed tomography (CT) scores may improve survival prediction models such as the lung allocation score (LAS). Objectives: This study investigated the association between...... CT and survival in CF patients screened for LTX. Methods: Clinical data and chest CTs of 411 CF patients screened for LTX between 1990 and 2005 were collected from 17 centers. CTs were scored with the Severe Advanced Lung Disease (SALD) 4-category scoring system, including the components "infection....../inflammation" (INF), air trapping/hypoperfusion (AT), normal/hyperperfusion (NOR) and bulla/cysts (BUL). The volume of each component was computed using semi-automated software. Survival analysis included Kaplan-Meier curves, and Cox-regression models. Measurements and main results: 366 (186 males) out of 411...

  12. Urinary bladder cancer: role of MR imaging.

    Science.gov (United States)

    Verma, Sadhna; Rajesh, Arumugam; Prasad, Srinivasa R; Gaitonde, Krishnanath; Lall, Chandana G; Mouraviev, Vladimir; Aeron, Gunjan; Bracken, Robert B; Sandrasegaran, Kumaresan

    2012-01-01

    Urinary bladder cancer is a heterogeneous disease with a variety of pathologic features, cytogenetic characteristics, and natural histories. It is the fourth most common cancer in males and the tenth most common cancer in females. Urinary bladder cancer has a high recurrence rate, necessitating long-term surveillance after initial therapy. Early detection is important, since up to 47% of bladder cancer-related deaths may have been avoided. Conventional computed tomography (CT) and magnetic resonance (MR) imaging are only moderately accurate in the diagnosis and local staging of bladder cancer, with cystoscopy and pathologic staging remaining the standards of reference. However, the role of newer MR imaging sequences (eg, diffusion-weighted imaging) in the diagnosis and local staging of bladder cancer is still evolving. Substantial advances in MR imaging technology have made multiparametric MR imaging a feasible and reasonably accurate technique for the local staging of bladder cancer to optimize treatment. In addition, whole-body CT is the primary imaging technique for the detection of metastases in bladder cancer patients, especially those with disease that invades muscle. © RSNA, 2012.

  13. 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.

    Science.gov (United States)

    Giraudo, Chiara; Raderer, Markus; Karanikas, Georgios; Weber, Michael; Kiesewetter, Barbara; Dolak, Werner; Simonitsch-Klupp, Ingrid; Mayerhoefer, Marius E

    2016-03-01

    The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lymphoma and non-Hodgkin lymphoma, without restriction to FDG-avid subytpes. Patients with histologically proven lymphoma were enrolled in this prospective, institutional review board-approved study. After a single F-FDG injection, patients consecutively underwent F-FDG PET[Fraction Slash]CT and F-FDG PET/MR on the same day for staging or restaging. Three sets of images were analyzed separately: F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR with DWI. Region-based agreement and examination-based sensitivity and specificity were calculated for F-FDG PET/CT, F-FDG PET/MR without DWI, and F-FDG PET/MR DWI. Maximum and mean standardized uptake values (SUVmax, SUVmean) on F-FDG PET/CT and F-FDG PET/MR were compared and correlated with minimum and mean apparent diffusion coefficients (ADCmin, ADCmean). Thirty-four patients with a total of 40 examinations were included. Examination-based sensitivities for F-FDG PET/CT, F-FDG PET/MR, and F-FDG PET/MR DWI were 82.1%, 85.7%, and 100%, respectively; specificities were 100% for all 3 techniques; and accuracies were 87.5%, 90%, and 100%, respectively. F-FDG PET/CT was false negative in 5 of 40 examinations (all with mucosa-associated lymphoid tissue lymphoma), and F-FDG PET/MR (without DWI) was false negative in 4 of 40 examinations. Region-based percentages of agreement were 99% (κ, 0.95) between F-FDG PET/MR DWI and F-FDG PET/CT, 99.2% (κ, 0.96) between F-FDG PET/MR and F-FDG PET/CT, and 99.4% (κ, 0.97) between F-FDG PET/MR DWI and F-FDG PET/MR. There was a strong correlation between F-FDG PET/CT and F-FDG PET/MR for SUVmax (r = 0.83) and SUVmean (r = 0.81) but no significant correlation between ADCmin and SUVmax

  14. Functional evaluation of the kidney by diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Hasegawa, Taro; Hasegawa, Norio; Irie, Takeo; Fukuda, Kunihiko

    2003-01-01

    The purpose of this study was to determine the relationship between the apparent diffusion coefficient (ADC) and diffuse renal disease by diffusion-weighted echo planar magnetic resonance (MR) imaging (EPI). Ten volunteers, seven patients with chronic renal failure and eighteen recipients of renal transplants were examined with diffusion-weighted EPI. We compared renal function (serum creatinine level) with provided ADC value. The average ADC values were 2.63 x 10 -3 mm 2 /sec for the whole kidney, 2.67 x 10 -3 mm 2 /sec for the cortex and 2.61 x 10 -3 mm 2 /sec for the medulla in normal kidneys. ADC values in the whole kidney, the cortex and the medulla in chronic renal failure were significantly lower than those for normal kidneys. In renal transplantation kidneys, the ADC values in the cortex were significantly lower than those for normal kidney. There was a linear correlation between ADC value and serum creatinine level. Our results show that diffusion-weighted MR imaging may be useful to identify renal dysfunction. (author)

  15. An overview of PET/MR, focused on clinical applications.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Masch, William Roger; Catana, Ciprian; Mahmood, Umar; Sahani, Dushyant Vasudeo; Gee, Michael Stanley; Menezes, Leon; Soricelli, Andrea; Salvatore, Marco; Gervais, Debra; Rosen, Bruce Robert

    2017-02-01

    Hybrid PET/MR scanners are innovative imaging devices that simultaneously or sequentially acquire and fuse anatomical and functional data from magnetic resonance (MR) with metabolic information from positron emission tomography (PET) (Delso et al. in J Nucl Med 52:1914-1922, 2011; Zaidi et al. in Phys Med Biol 56:3091-3106, 2011). Hybrid PET/MR scanners have the potential to greatly impact not only on medical research but also, and more importantly, on patient management. Although their clinical applications are still under investigation, the increased worldwide availability of PET/MR scanners, and the growing published literature are important determinants in their rising utilization for primarily clinical applications. In this manuscript, we provide a summary of the physical features of PET/MR, including its limitations, which are most relevant to clinical PET/MR implementation and to interpretation. Thereafter, we discuss the most important current and emergent clinical applications of such hybrid technology in the abdomen and pelvis, both in the field of oncologic and non-oncologic imaging, and we provide, when possible, a comparison with clinically consolidated imaging techniques, like for example PET/CT.

  16. Atlas and toolbook of MR mammography; Lehratlas der MR-Mammographie

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, U. [Universitaetsklinikum Goettingen (Germany). Abt. Roentgendiagnostik I; Brinck, U. [Universitaetsklinikum Goettingen (Germany). Abt. Pathologie und Pathologische Anatomie

    2000-07-01

    This richly illustrated toolbook and atlas contains information on all aspects of nmr diagnostic imaging of benign or malignant neoplasms of female and male mammary glands. It offers pinpointed guidance and insight for vocational training and continuing training of radiology assistants, students and medical radiologists. (orig./AJ) [German] Die MRT als hochaufloesendes und schaedigungsfreies Diagnostikum gewinnt gerade in der emotional stark besetzten Mammadiagnostik zunehmend an Bedeutung. Dennoch beherrschen nur wenige Zentren im deutschsprachigen Raum diese Technik, die - eine hohe Reproduzierbarkeit bei fehlender Belastung fuer die Patientin bietet, - invasive Karzinome bereits ab einer Groesse von 5 mm mit hoher Zuverlaessigkeit ausschliessen kann und - gerade bei widerspruechlichen Befunden zwischen klinischer Untersuchung, Roentgenmammographie und perkutaner Biopsie eine wesentliche Entscheidungshilfe bieten kann. Aus einem der fuehrenden Zentren in der MR-Mammographie wurde daher dieser praxisnahe, opulent ausgestattete und weit ueber die reine Bildinformation hinausgehende 'Einstiegs- und Lehratlas' entwickelt. Er bietet Radiologen in Fort- und Weiterbildung, aber auch Gynaekologen mit ueber 400 Abbildungen klare Antworten auf die Fragen. (orig./AJ)

  17. Functional MRI of the cervical spine after distortion injury; MR-Funktionsdiagnostik der Halswirbelsaeule nach Schleudertrauma

    Energy Technology Data Exchange (ETDEWEB)

    Schnarkowski, P. [Muenchen Univ. (Germany). Inst. fuer Radiologische Diagnostik; Weidenmaier, W. [Muenchen Univ. (Germany). Inst. fuer Radiologische Diagnostik; Heuck, A. [Muenchen Univ. (Germany). Inst. fuer Radiologische Diagnostik; Reiser, M.F. [Muenchen Univ. (Germany). Inst. fuer Radiologische Diagnostik

    1995-04-01

    50 patients with a history of distortion injury of the cervical spine were examined with static and functional MRI. Functional MRI consisted of different patient`s positions from maximal extension to maximal flexion (30 , 0 , 25 , 40 , 50 ). T{sub 2}*-weighted gradient echo sequences were performed in a sagittal view for the different positions. Ligamentous instabilities and disc protrusions were seen only in functional MRI in 17 patients. These findings correlated with the neurological symptoms. Two patients were treated by operative fusion because of these findings. (orig.) [Deutsch] Bei 50 Patienten mit einem Schleudertrauma der Halswirbelsaeule wurden zu den statischen Magnetresonanztomogrammen der Halswirbelsaeule MR-Funktionsaufnahmen durchgefuehrt. Diese Funktionsaufnahmen erfolgten in 5 verschiedenen Flexionsgraden von maximaler Reklination bis zur maximalen Inklination (30 , 0 , 25 , 40 , 50 ). T{sub 2}*-gewichtete Gradienten-Echo-Sequenzen in sagittaler Schnittfuehrung wurden fuer jeden Flexionsgrad angefertigt. Bandinstabilitaeten und Bandscheibenvorwoelbungen konnten bei 17 Patienten nur in bestimmten Flexionsgraden erfasst werden. Diese 17 Patienten zeigten eine umschriebene neurologische Symptomatik, die von ihrer Lokalisation mit den in der MR-Funktionsdiagnostik erhobenen Befunden korrelierten. Zwei Patienten wurden aufgrund diese Befunde mit einer operativen Fusion therapiert. (orig.)

  18. Primary Nocardia Infection Causing a Fluorodeoxyglucose-Avid Right Renal Mass in a Redo Lung Transplant Recipient

    Directory of Open Access Journals (Sweden)

    Sreeja Biswas Roy

    2018-01-01

    Full Text Available Immunosuppression after lung transplantation may increase susceptibility to opportunistic infection and is associated with early and delayed deaths in lung transplant recipients. Factors that may predispose lung transplant recipients to opportunistic bacterial and fungal infections include prolonged corticosteroid use, renal impairment, treatment of acute rejection, and post-transplant diabetes mellitus. We present a unique case of a 63-year-old woman with diabetes mellitus who underwent redo lung transplantation. Three years after her right-sided single redo lung transplant, she presented with right-sided abdominal pain, nausea, and vomiting. Upon examination, computed tomography showed a 4.5 × 3.3 cm heterogeneous, enhancing right renal mass with a patent renal vein. Magnetic resonance imaging confirmed a T1/T2 hypointense, diffusion-restricting, right mid-renal mass that was fluorodeoxyglucose-avid on positron emission tomography. We initially suspected primary renal cell carcinoma. However, after a right nephrectomy, no evidence of neoplasia was observed; instead, a renal abscess containing filamentous bacteria was noted, raising suspicion for infection of the Nocardia species. Special stains confirmed a diagnosis of Nocardia renal abscess. Computed tomography of the chest and brain revealed no lesions consistent with infection. We initiated a long-term therapeutic regimen of anti-Nocardia therapy with imipenem and trimethoprim-sulfamethoxazole.

  19. Microvascular anastomosis in rodent model evaluated by Fourier domain Doppler optical coherence tomography

    Science.gov (United States)

    Huang, Yong; Tong, Dedi; Zhu, Shan; Wu, Lehao; Ibrahim, Zuhaib; Lee, WP Andrew; Brandacher, Gerald; Kang, Jin U.

    2014-03-01

    Vascular and microvascular anastomosis are critical components of reconstructive microsurgery, vascular surgery and transplant surgery. Imaging modality that provides immediate, real-time in-depth view and 3D structure and flow information of the surgical site can be a great valuable tool for the surgeon to evaluate surgical outcome following both conventional and innovative anastomosis techniques, thus potentially increase the surgical success rate. Microvascular anastomosis for vessels with outer diameter smaller than 1.0 mm is extremely challenging and effective evaluation of the outcome is very difficult if not impossible using computed tomography (CT) angiograms, magnetic resonance (MR) angiograms and ultrasound Doppler. Optical coherence tomography (OCT) is a non-invasive high-resolution (micron level), high-speed, 3D imaging modality that has been adopted widely in biomedical and clinical applications. Phaseresolved Doppler OCT that explores the phase information of OCT signals has been shown to be capable of characterizing dynamic blood flow clinically. In this work, we explore the capability of Fourier domain Doppler OCT as an evaluation tool to detect commonly encountered post-operative complications that will cause surgical failure and to confirm positive result with surgeon's observation. Both suture and cuff based techniques were evaluated on the femoral artery and vein in the rodent model.

  20. Sound radiation contrast in MR phase images. Method for the representation of elasticity, sound damping, and sound impedance changes; Schallstrahlungskontrast in MR-Phasenbildern. Methode zur Darstellung von Elastizitaets-, Schalldaempfungs- und Schallimpedanzaenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Radicke, Marcus

    2009-12-18

    The method presented in this thesis combines ultrasound techniques with the magnetic-resonance tomography (MRT). An ultrasonic wave generates in absorbing media a static force in sound-propagation direction. The force leads at sound intensities of some W/cm{sup 2} and a sound frequency in the lower MHz range to a tissue shift in the micrometer range. This tissue shift depends on the sound power, the sound frequency, the sound absorption, and the elastic properties of the tissue. A MRT sequence of the Siemens Healthcare AG was modified so that it measures (indirectly) the tissue shift, codes as grey values, and presents as 2D picture. By means of the grey values the sound-beam slope in the tissue can be visualized, and so additionally sound obstacles (changes of the sound impedance) can be detected. By the MRT images token up spatial changes of the tissue parameters sound absorption and elasticity can be detected. In this thesis measurements are presented, which show the feasibility and future chances of this method especially for the mammary-cancer diagnostics. [German] Die in dieser Arbeit praesentierte Methode kombiniert Ultraschalltechniken mit der Magnetresonanztomographie (MRT). Eine Ultraschallwelle ruft in absorbierenden Medien eine statische Kraft in Schallausbreitungsrichtung hervor. Die Kraft fuehrt bei Schallintensitaeten von einigen W/cm{sup 2} und einer Schallfrequenz im niederen MHz-Bereich zu einer Gewebeverschiebung im Mikrometerbereich. Diese Gewebeverschiebung haengt ab von der Schallleistung, der Schallfrequenz, der Schallabsorption und den elastischen Eigenschaften des Gewebes. Es wurde eine MRT-Sequenz der Siemens Healthcare AG modifiziert, so dass sie (indirekt) die Gewebeverschiebung misst, als Grauwerte kodiert und als 2D-Bild darstellt. Anhand der Grauwerte kann der Schallstrahlverlauf in dem Gewebe visualisiert werden, und so koennen zusaetzlich Schallhindernisse (Aenderungen der Schallkennimpedanz) aufgespuert werden. Mit den

  1. Spine Trabecular Bone Score as an Indicator of Bone Microarchitecture at the Peripheral Skeleton in Kidney Transplant Recipients.

    Science.gov (United States)

    Luckman, Matthew; Hans, Didier; Cortez, Natalia; Nishiyama, Kyle K; Agarawal, Sanchita; Zhang, Chengchen; Nikkel, Lucas; Iyer, Sapna; Fusaro, Maria; Guo, Edward X; McMahon, Donald J; Shane, Elizabeth; Nickolas, Thomas L

    2017-04-03

    Studies using high-resolution peripheral quantitative computed tomography showed progressive abnormalities in cortical and trabecular microarchitecture and biomechanical competence over the first year after kidney transplantation. However, high-resolution peripheral computed tomography is a research tool lacking wide availability. In contrast, the trabecular bone score is a novel and widely available tool that uses gray-scale variograms of the spine image from dual-energy x-ray absorptiometry to assess trabecular quality. There are no studies assessing whether trabecular bone score characterizes bone quality in kidney transplant recipients. Between 2009 and 2010, we conducted a study to assess changes in peripheral skeletal microarchitecture, measured by high-resolution peripheral computed tomography, during the first year after transplantation in 47 patients managed with early corticosteroid-withdrawal immunosuppression. All adult first-time transplant candidates were eligible. Patients underwent imaging with high-resolution peripheral computed tomography and dual-energy x-ray absorptiometry pretransplantation and 3, 6, and 12 months post-transplantation. We now test if, during the first year after transplantation, trabecular bone score assesses the evolution of bone microarchitecture and biomechanical competence as determined by high-resolution peripheral computed tomography. At baseline and follow-up, among the 72% and 78%, respectively, of patients having normal bone mineral density by dual-energy x-ray absorptiometry, 53% and 50%, respectively, were classified by trabecular bone score as having high fracture risk. At baseline, trabecular bone score correlated with spine, hip, and ultradistal radius bone mineral density by dual-energy x-ray absorptiometry and cortical area, density, thickness, and porosity; trabecular density, thickness, separation, and heterogeneity; and stiffness and failure load by high-resolution peripheral computed tomography

  2. von Neumann Morgenstern Preferences

    DEFF Research Database (Denmark)

    Vind, Karl

    von Neumann Morgenstern utility is generalized to von Neumann Morgenstern preferences. The proof is an application of simple hyperplane theorems......von Neumann Morgenstern utility is generalized to von Neumann Morgenstern preferences. The proof is an application of simple hyperplane theorems...

  3. von Neumann Morgenstern Preferences

    DEFF Research Database (Denmark)

    Vind, Karl

    2000-01-01

    von Neumann Morgenstern utility is generalized to von Neumann Morgenstern preferences. The proof is an application of simple hyperplane theorems......von Neumann Morgenstern utility is generalized to von Neumann Morgenstern preferences. The proof is an application of simple hyperplane theorems...

  4. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    International Nuclear Information System (INIS)

    Yeung, Timothy P C; Yartsev, Slav; Lee, Ting-Yim; Wong, Eugene; He, Wenqing; Fisher, Barbara; VanderSpek, Lauren L; Macdonald, David; Bauman, Glenn

    2014-01-01

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity

  5. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Timothy P C [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Lee, Ting-Yim [Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Imaging, The University of Western Ontario, London Health Sciences Centre, Victoria Hospital, Ontario, Canada, N6A 5W9 (Australia); Lawson Health Research Institute, St. Joseph' s Health Care London, Ontario, Canada, N6A 4V2 (Canada); Wong, Eugene [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Physics and Astronomy, The University of Western Ontario, Ontario, Canada, N6A 3K7 (Canada); He, Wenqing [Department of Statistical and Actuarial Sciences, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Fisher, Barbara; VanderSpek, Lauren L [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Macdonald, David [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Clinical Neurological Sciences, The University of Western Ontario, London Health Sciences Centre, University Hospital, Ontario, Canada, N6A 5A5 (Canada); Bauman, Glenn, E-mail: glenn.bauman@lhsc.on.ca [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada)

    2014-02-15

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

  6. Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

    Science.gov (United States)

    Lang, P.; Genant, H. K.; Jergesen, H. E.; Murray, W. R.

    1992-01-01

    The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

  7. PET/MR: improvement of the UTE μ-maps using modified MLAA

    Energy Technology Data Exchange (ETDEWEB)

    Benoit, Didier [Rigshospitalet, University of Copenhagen (Denmark); Ladefoged, Claes [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet Copenhagen (Denmark); Rezaei, Ahmadreza [University of Leuven (Belgium); Keller, Sune; Andersen, Flemming; Hojgaard, Liselotte [Rigshospitalet, University of Copenhagen (Denmark); Hansen, Adam Espe [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet Copenhagen (Denmark); Holm, Soren [Rigshospitalet, University of Copenhagen (Denmark); Nuyts, Johan [University of Leuven (Belgium)

    2015-05-18

    For a quantitative analysis in positron emission tomography (PET) or single-photon emission computed tomography (SPECT), attenuation correction (AC) is mandatory. CTscans or transmission scans are common tools for determination of the attenuation μ-map, but in the case of a PET/MR hybrid system it is difficult to associate one of these scans. Many techniques have been developed in order to improve AC for PET/MR. Some methods are based on template- or atlas techniques, other methods apply a segmentation technique based on Dixon or UTE (Ultrashort Echo Time) MR to create the μ-map, followed by a standard OSEM reconstruction (OSEM/DIXON and OSEM/UTE). A different approach for AC has been developed by employing the emission sinogram data in the μ-map derivation. In this context, we modified the iterative MLAA (Maximum-Likelihood reconstruction of Attenuation and Activity) algorithm to improve the resulting emission image from the PET/MR system. We constrained the attenuation map update using the UTE μ-map and the T1-weighted (T1w) MR image in order to improve convergence towards a solution. Results show that the modified MLAA algorithm improved the estimated emission image compared to standard OSEM/UTE and OSEM/DIXON. In certain regions of the brain, in particular close to the skull and the air cavities, the modified MLAA algorithm generated less error than OSEM/UTE and OSEM/Dixon. The modified MLAA algorithm is able to compute an attenuation μ-map that is slightly more similar to the aligned CT μ-map than the UTE μ-map.

  8. Sports-related muscle injuries of the lower extremity: MR imaging appearances

    International Nuclear Information System (INIS)

    Sanchez-Marquez, A.; Gil-Garcia, M.; Valls, C.; Narvaez-Garcia, J.; Andia-Navarro, E.; Pozuelo-Segura, O.; Portabella-Blavia, F.

    1999-01-01

    Sports-related injuries of the lower extremity are frequent. Before magnetic resonance (MR) imaging was available, ultrasound, radionuclide scintigraphy and computed tomography were used to evaluate muscle trauma. Although relatively inexpensive, these imaging modalities are limited by their low specificity. The high degree of soft tissue contrast and multiplanar capability of MR imaging, allow direct visualization as well as characterization of traumatic muscle lesions. This pictorial review highlights the spectrum of traumatic muscle lesions on MRI, with emphasis on its typical appearances. (orig.)

  9. Brain MRI findings in acute hepatic encephalopathy in liver transplant recipients.

    Science.gov (United States)

    Guo, Ruo-Mi; Li, Qing-Ling; Zhong, Li-Ru; Guo, Yu; Jiao, Ju; Chen, Shao-Qiong; Wang, Jin; Zhang, Yong

    2018-06-01

    Acute hepatic encephalopathy has significant morbidity and mortality in liver transplant recipients unless it is promptly treated. We evaluated the brain magnetic resonance (MR) imaging findings associated with acute hepatic encephalopathy in transplant recipients. We retrospectively reviewed the clinical and imaging data and outcomes of twenty-five liver transplant patients (16 male; mean age, 49.3 years) with clinically diagnosed acute hepatic encephalopathy and forty liver transplant patients (20 males; mean age, 45.5 years) without neurological symptoms suggestive of hepatic encephalopathy at our institution. Bilateral symmetric hyperintensities of the insular cortex and cingulate gyrus were observed in twenty-one patients (84.00%), bilateral symmetric extensive increased cortical signal intensity (involving two or more regions) was observed in 72.00% of the patients, leptomeningeal enhancement in 73.68%, and visualization of prominent venules in 52.00%. The most common symptom at diagnosis was rigidity (n = 14), and the plasma ammonia levels ranged from 68.63 to 192.16 μmol/L. After active treatment, 17 patients gradually recovered, four patients suffered from mild or moderate neurologic deficits, and four patients with widespread brain edema died. The specific brain MR imaging features were bilateral symmetric increased cortical signal intensity, especially in the insular cortex and cingulate gyrus, leptomeningeal enhancement, visualization of the prominent venules, and widespread brain edema. These features may indicate poor prognosis and should alert radiologists to the possibility of acute hepatic encephalopathy in liver transplant recipients and encourage clinicians to prepare appropriate treatment in advance.

  10. Osteoidosteoma. From diagnosis to treatment; Osteoidosteom. Von der Diagnose zur Behandlung

    Energy Technology Data Exchange (ETDEWEB)

    Sprengel, S.D.; Weber, M.A.; Lehner, B.; Rehnitz, C. [Stiftung Orthopaedische Universitaetsklinik, Universitaetsklinikum Heidelberg, Sektion Muskuloskelettale Radiologie, Diagnostische und Interventionelle Radiologie, Heidelberg (Germany)

    2015-06-15

    An osteoid osteoma is a benign bone-forming tumor which usually presents in childhood and adolescence and is characterized by extensive nocturnal pain. Computed tomography (CT) is used to reveal the typical radiolucent nidus surrounded by a sclerotic reaction and in magnetic resonance imaging (MRI) a nidal enhancement and perifocal edema can confirm the diagnosis. Having shown excellent success rates radiofrequency ablation has become the treatment of choice which allows minimally invasive and precise destruction of nidal tumor tissue. By using thermal protection techniques and multiple ablation positions successful therapy of perineural tumors and niduses with diameters of more than 2 cm are possible. (orig.) [German] Das Osteoidosteom ist ein gutartiger knochenbildender Tumor, welcher eine ausgepraegte Nachtschmerzsymptomatik zeigt und vorwiegend bei Kindern und Jugendlichen auftritt. Charakteristisch sind ein radioluzenter Nidus, umgeben von einer meist ausgepraegten Sklerosereaktion in der Computertomographie, sowie eine nidale Kontrastmittelaufnahme mit perifokalem Oedem in der Magnetresonanztomographie. Therapie der Wahl ist die minimal-invasive Radiofrequenzablation, welche eine komplikationsarme, zielgenaue Destruktion des Tumorgewebes ermoeglicht und eine exzellente klinische Erfolgsrate aufweist. Thermale Protektionstechniken und der Einsatz multipler Ablationspositionen ermoeglichen Ablationen von Tumoren mit direktem Lagebezug zu Nerven oder dem Spinalkanal und Durchmessern von ueber 2 cm. (orig.)

  11. Evaluation of attenuation correction in cardiac PET using PET/MR.

    Science.gov (United States)

    Lau, Jeffrey M C; Laforest, R; Sotoudeh, H; Nie, X; Sharma, S; McConathy, J; Novak, E; Priatna, A; Gropler, R J; Woodard, P K

    2017-06-01

    Simultaneous acquisition Positron emission tomography/magnetic resonance (PET/MR) is a new technology that has potential as a tool both in research and clinical diagnosis. However, cardiac PET acquisition has not yet been validated using MR imaging for attenuation correction (AC). The goal of this study is to evaluate the feasibility of PET imaging using a standard 2-point Dixon volume interpolated breathhold examination (VIBE) MR sequence for AC. Evaluation was performed in both phantom and patient data. A chest phantom containing heart, lungs, and a lesion insert was scanned by both PET/MR and PET/CT. In addition, 30 patients underwent whole-body 18 F-fluorodeoxyglucose PET/CT followed by simultaneous cardiac PET/MR. Phantom study showed 3% reduction of activity values in the myocardium due to the non-inclusion of the phased array coil in the AC. In patient scans, average standardized uptake values (SUVs) obtained by PET/CT and PET/MR showed no significant difference (n = 30, 4.6 ± 3.5 vs 4.7 ± 2.8, P = 0.47). There was excellent per patient correlation between the values acquired by PET/CT and PET/MR (R 2  = 0.97). Myocardial SUVs PET imaging using MR for AC shows excellent correlation with myocardial SUVs obtained by standard PET/CT imaging. The 2-point Dixon VIBE MR technique can be used for AC in simultaneous PET/MR data acquisition.

  12. Acute chest pain: The role of MR imaging and MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hunold, Peter, E-mail: peter.hunold@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Bischoff, Peter, E-mail: peter.bischoff@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Barkhausen, Jörg, E-mail: joerg.barkhausen@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany); Vogt, Florian M., E-mail: florian.vogt@uk-sh.de [Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck (Germany)

    2012-12-15

    MR imaging (MRI) and MR angiography (MRA) have gained a high level of diagnostic accuracy in cardiovascular disease. MRI in cardiac disease has been established as the non-invasive standard of reference in many pathologies. However, in acute chest pain the situation is somewhat special since many of the patients presenting in the emergency department suffer from potentially life-threatening disease including acute coronary syndrome, pulmonary embolism, and acute aortic syndrome. Those patients need a fast and definitive evaluation under continuous monitoring of vital parameters. Due to those requirements MRI seems to be less suitable compared to X-ray coronary angiography and multislice computed tomography angiography (CTA). However, MRI allows for a comprehensive assessment of all clinically stable patients providing unique information on the cardiovascular system including ischemia, inflammation and function. Furthermore, MRI and MRA are considered the method of choice in patients with contraindications to CTA and for regular follow-up in known aortic disease. This review addresses specific features of MRI and MRA for different cardiovascular conditions presenting with acute chest pain.

  13. Magnetic resonance imaging-guided attenuation correction of positron emission tomography data in PET/MRI

    OpenAIRE

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-01-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined positron emission tomography/magnetic resonance imaging (PET/MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients (LACs) of the tissues and other components located in the PET field of view (FoV). MR-AC methods can be divided into three main categories: segmentation-, atlas- and PET-based. This review aims to...

  14. Decreased cerebral blood flow in renal transplant recipients

    International Nuclear Information System (INIS)

    Kamano, Chisako; Komaba, Yuichi; Sakayori, Osamu; Iino, Yasuhiko; Katayama, Yasuo

    2002-01-01

    We performed single-photon emission computed tomography (SPECT) to investigate the influence of renal transplantation on cerebral blood flow (CBF). Fifteen renal transplant recipients and twelve normal subjects underwent cerebral SPECT with N-isopropyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP). All transplant recipients received prednisolone and cyclosporine (CyA). Regional CBF (rCBF) was measured by defining regions of interest in the cerebral cortex, deep white matter, striatum, thalamus, and cerebellum. In transplant recipients, correlations to the mean overall cortical CBF were assessed using the interval from transplantation to measurement of SPECT, as well as the serum creatinine concentration. Moreover, to investigate the influence of CyA on CBF, the correlation between mean overall cortical CBF and CyA trough concentrations was assessed. In all regions, CBF in renal transplant recipients was significantly lower than in normal subjects. No significant correlation was seen between serum creatinine, interval from transplantation, or CyA trough concentrations and mean overall cortical CBF. Renal transplant recipients demonstrated a decrease in CBF, that can have an associated secondary pathology. Therefore, renal transplant recipients may benefit from post-operative MRI or CT. (author)

  15. Multimodal Registration of gated cardiac PET, CT and MR sequences

    International Nuclear Information System (INIS)

    Baty, X.

    2007-07-01

    The research described in this manuscript deals with the multimodal registration of cardiac images from Magnetic Resonance Imaging (MRI), Position Emission Tomography (PET) and Computerized Tomography (CT). All these modalities are gated to the Electrocardiogram (ECG) and provide information to evaluate cardiac function, and to diagnose and to follow-up cardiovascular pathologies. PET imaging allows the evaluation of ventricular function and MRI is a gold standard for the study of the left ventricular function. The goal of our registration process is to merge functional (from PET) and anatomical images (from CT and MRI). Our process is adapted to the modalities used and is divided in two steps: (i) a global rigid 3-dimensional model-based ICP (Iterative Closest Point) registration between CT and MR data and (ii) an iconic 2-dimensional registration based on Free Form Deformations and Mutual Information. This last step presents an original contribution by using a composite image of CT (which presents epicardic contours) and PET (where endocardic contours are partially visible) data to make mutual information more accurate in representing the similarity with the MR data. To speed up the whole process, we also present a transformation initialization scheme using displacement field obtained form MR data only. The obtained results have been evaluated by experts. (author)

  16. The history of MR imaging as seen through the pages of radiology.

    Science.gov (United States)

    Edelman, Robert R

    2014-11-01

    The first reports in Radiology pertaining to magnetic resonance (MR) imaging were published in 1980, 7 years after Paul Lauterbur pioneered the first MR images and 9 years after the first human computed tomographic images were obtained. Historical advances in the research and clinical applications of MR imaging very much parallel the remarkable advances in MR imaging technology. These advances can be roughly classified into hardware (eg, magnets, gradients, radiofrequency [RF] coils, RF transmitter and receiver, MR imaging-compatible biopsy devices) and imaging techniques (eg, pulse sequences, parallel imaging, and so forth). Image quality has been dramatically improved with the introduction of high-field-strength superconducting magnets, digital RF systems, and phased-array coils. Hybrid systems, such as MR/positron emission tomography (PET), combine the superb anatomic and functional imaging capabilities of MR imaging with the unsurpassed capability of PET to demonstrate tissue metabolism. Supported by the improvements in hardware, advances in pulse sequence design and image reconstruction techniques have spurred dramatic improvements in imaging speed and the capability for studying tissue function. In this historical review, the history of MR imaging technology and developing research and clinical applications, as seen through the pages of Radiology, will be considered.

  17. Near infra-red chemical species tomography of sprays of volatile hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Hindle, F.P.; Carey, S.J.; Ozanyan, K.B.; McCann, H. [Dept. of Electrical Engineering and Electronics, UMIST, Manchester (United Kingdom); Winterbone, D.E.; Clough, E. [Dept. of Mechanical, Aerospace and Mfg. Engineering, UMIST, Manchester (United Kingdom)

    2002-08-01

    We report an All-Opto-Electronic tomography system that is sensitive to hydrocarbon vapour distribution, or liquid spray distribution, with temporal resolution of over 3000 frames per second. A tomography system comprising 32 channels has been built and tested. For chemical sensitivity to saturated hydrocarbons, we exploit the principle of Near Infra-Red (NIR) absorption at 1700 nm relative to a reference wavelength, using laser diode sources whose technology is based on that of the communications industry. Images are obtained from a laboratory set-up incorporating both gaseous injection and a liquid Gasoline Direct Injection (GDI) system. The performance of a prototype system on a running GDI engine is reported. The difficulty in performing concentration measurements of the gaseous fuel within the liquid spray region is shown, and means to improve this performance are discussed. However, it has been found possible to image the liquid spray cone using attenuation of the reference beam. These images correlate well with other techniques [1]. (orig.) [German] Wir berichten ueber ein optoelektronisches Tomographiesystem zur Bestimmung der Verteilung von Kohlenwasserstoffdaempfen oder von Spraypartikeln, das eine hohe zeitliche Aufloesung von 3000 Aufnahmen pro Sekunde liefert. Ein System mit 32 Kanaelen wurde gebaut und getestet. Um Empfindichkeit auf gesaettigte Kohlenwasserstoffdaempfe zu erzielen, wurde die Absorption im Nahen Infrarot (NIR) bei 1700 nm, bezogen auf die bei einer Referenzwellen-laenge, genutzt. Laserdioden, deren Technologien auch in der Kommunikationstechnik Verwendung finden, kamen zum Einsatz. Von einem Laboraufbau wurden Bilder aufgenommen sowohl bei Injektion von Gas als auch bei Direkteinspritzung fluessigen Brennstoffs (GDI). Wir berichten ueber die Ergebnisse mit dem Prototyp-Messsystem an einem GDI-Motor. Es werden die Schwierigkeiten gezeigt, Messungen der Gaskonzentration innerhalb eines Spraypartikelbereichs durchzufuehren, und

  18. Doença de von Willebrand e anestesia Enfermedad de von Willebrand y anestesia Von Willebrand's disease and anesthesia

    Directory of Open Access Journals (Sweden)

    Fabiano Timbó Barbosa

    2007-06-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A doença de von Willebrand ocorre devido à mutação no cromossomo 12 e é caracterizada por deficiência qualitativa ou quantitativa do fator de von Willebrand. A diversidade de mutações leva ao aparecimento das mais variadas manifestações clínicas possibilitando a divisão dos pacientes em vários tipos e subtipos clínicos. A coagulopatia se manifesta basicamente através da disfunção plaquetária associada à diminuição dos níveis séricos do fator VIII coagulante. O objetivo dessa revisão foi mostrar os cuidados relacionados aos pacientes portadores da doença de von Willebrand durante o período perioperatório. CONTEÚDO: Foram definidas as características da doença de von Willebrand quanto à fisiopatologia, à classificação, ao diagnóstico laboratorial, ao tratamento atual e aos cuidados com o manuseio do paciente no período perioperatório. CONCLUSÕES: A doença de von Willebrand é o distúrbio hemorrágico hereditário mais comum, porém ela é subdiagnosticada pela complexidade da própria doença. A correta classificação do paciente, o uso apropriado da desmopressina e a transfusão do fator de von Willebrand são medidas fundamentais para a realização do procedimento anestésico bem-sucedido.JUSTIFICATIVA Y OBJETIVOS: La enfermedad de von Willebrand ocurre debido a la mutación en el cromosoma 12 y se caracteriza por la deficiencia cualitativa o cuantitativa del factor de von Willebrand. La diversidad de mutaciones conlleva al aparecimiento de las más variadas manifestaciones clínicas posibilitando la división de los pacientes en varios tipos y subtipos clínicos. La coagulopatía se manifiesta básicamente a través de la disfunción plaquetaria asociada con la disminución de los niveles séricos del factor VIII coagulante. El objetivo de esa revisión fue mostrar los cuidados relacionados con las pacientes portadoras de la enfermedad de von Willebrand durante el per

  19. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

    Science.gov (United States)

    Hofmann, Matthias; Pichler, Bernd; Schölkopf, Bernhard; Beyer, Thomas

    2009-03-01

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data.

  20. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques

    International Nuclear Information System (INIS)

    Hofmann, Matthias; Pichler, Bernd; Schoelkopf, Bernhard; Beyer, Thomas

    2009-01-01

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data. (orig.)

  1. Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Matthias [Max Planck Institute for Biological Cybernetics, Tuebingen (Germany); University of Tuebingen, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Radiology, Tuebingen (Germany); University of Oxford, Wolfson Medical Vision Laboratory, Department of Engineering Science, Oxford (United Kingdom); Pichler, Bernd [University of Tuebingen, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Radiology, Tuebingen (Germany); Schoelkopf, Bernhard [Max Planck Institute for Biological Cybernetics, Tuebingen (Germany); Beyer, Thomas [University Hospital Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany); Cmi-Experts GmbH, Zurich (Switzerland)

    2009-03-15

    Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We review and discuss these algorithms and point out challenges for using MR-AC in clinical routine. MR-AC is work-in-progress with potentially promising results from a template-based approach applicable to both brain and torso imaging. While efforts are ongoing in making clinically viable MR-AC fully automatic, further studies are required to realize the potential benefits of MR-based motion compensation and partial volume correction of the PET data. (orig.)

  2. FDG PET/MR for lymph node staging in head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Platzek, Ivan, E-mail: ivan.platzek@uniklinikum-dresden.de [Dresden University Hospital, Department of Radiology, Fetscherstr. 74, 01307 Dresden (Germany); Beuthien-Baumann, Bettina, E-mail: bettina.beuthien-baumann3@uniklinikum-dresden.de [Dresden University Hospital, Department of Nuclear Medicine, Fetscherstr. 74, 01307 Dresden (Germany); Schneider, Matthias, E-mail: m.schneider@mkgdresden.de [Dresden University Hospital, Department of Oral and Maxillofacial Surgery, Fetscherstr. 74, 01307 Dresden (Germany); Gudziol, Volker, E-mail: volker.gudziol@uniklinikum-dresden.de [Dresden University Hospital, Department of Otolaryngology, Fetscherstr. 74, 01307 Dresden (Germany); Kitzler, Hagen H., E-mail: hagen.kitzler@uniklinikum-dresden.de [Dresden University Hospital, Department of Neuroradiology, Fetscherstr. 74, 01307 Dresden (Germany); Maus, Jens, E-mail: j.maus@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmaceutical Cancer Research, Bautzner Landstr. 400, 01328 Dresden (Germany); Schramm, Georg, E-mail: g.schramm@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmaceutical Cancer Research, Bautzner Landstr. 400, 01328 Dresden (Germany); Popp, Manuel, E-mail: manuel.popp@praxisklinik-dresden.de [Dresden University Hospital, Department of Nuclear Medicine, Fetscherstr. 74, 01307 Dresden (Germany); Laniado, Michael, E-mail: michael.laniado@uniklinikum-dresden.de [Dresden University Hospital, Department of Radiology, Fetscherstr. 74, 01307 Dresden (Germany); Kotzerke, Jörg, E-mail: Joerg.Kotzerke@uniklinikum-dresden.de [Dresden University Hospital, Department of Nuclear Medicine, Fetscherstr. 74, 01307 Dresden (Germany); Hoff, Jörg van den, E-mail: j.van_den_hoff@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmaceutical Cancer Research, Bautzner Landstr. 400, 01328 Dresden (Germany)

    2014-07-15

    Objective: To assess the diagnostic value of PET/MR (positron emission tomography/magnetic resonance imaging) with FDG (18F-fluorodeoxyglucose) for lymph node staging in head and neck cancer. Materials and methods: This prospective study was approved by the local ethics committee; all patients signed informed consent. Thirty-eight patients with squamous cell carcinoma of the head and neck region underwent a PET scan on a conventional scanner and a subsequent PET/MR on a whole-body hybrid system after a single intravenous injection of FDG. The accuracy of PET, MR and PET/MR for lymph node metastases were compared using receiver operating characteristic (ROC) analysis. Histology served as the reference standard. Results: Metastatic disease was confirmed in 16 (42.1%) of 38 patients and 38 (9.7%) of 391 dissected lymph node levels. There were no significant differences between PET/MR, MR and PET and MR (p > 0.05) regarding accuracy for cervical metastatic disease. Based on lymph node levels, sensitivity and specificity for metastatic involvement were 65.8% and 97.2% for MR, 86.8% and 97.0% for PET and 89.5% and 95.2% for PET/MR. Conclusions: In head and neck cancer, FDG PET/MR does not significantly improve accuracy for cervical lymph node metastases in comparison to MR or PET.

  3. Imaging breast adipose and fibroglandular tissue molecular signatures by using hybrid MRI-guided near-infrared spectral tomography

    Science.gov (United States)

    Brooksby, Ben; Pogue, Brian W.; Jiang, Shudong; Dehghani, Hamid; Srinivasan, Subhadra; Kogel, Christine; Tosteson, Tor D.; Weaver, John; Poplack, Steven P.; Paulsen, Keith D.

    2006-06-01

    Magnetic resonance (MR)-guided near-infrared spectral tomography was developed and used to image adipose and fibroglandular breast tissue of 11 normal female subjects, recruited under an institutional review board-approved protocol. Images of hemoglobin, oxygen saturation, water fraction, and subcellular scattering were reconstructed and show that fibroglandular fractions of both blood and water are higher than in adipose tissue. Variation in adipose and fibroglandular tissue composition between individuals was not significantly different across the scattered and dense breast categories. Combined MR and near-infrared tomography provides fundamental molecular information about these tissue types with resolution governed by MR T1 images. hemoglobin | magnetic resonance imaging | water | fat | oxygen saturation

  4. High-resolution computed tomography findings of pulmonary tuberculosis in lung transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    Giacomelli, Irai Luis; Schuhmacher Neto, Roberto; Nin, Carlos Schuller; Cassano, Priscilla de Souza; Pereira, Marisa; Moreira, Jose da Silva; Nascimento, Douglas Zaione; Hochhegger, Bruno, E-mail: iraigiacomelli@gmail.com [Complexo Hospitalar Santa Casa de Porto Alegre, RS (Brazil)

    2017-07-15

    Objective: Respiratory infections constitute a major cause of morbidity and mortality in solid organ transplant recipients. The incidence of pulmonary tuberculosis is high among such patients. On imaging, tuberculosis has various presentations. Greater understanding of those presentations could reduce the impact of the disease by facilitating early diagnosis. Therefore, we attempted to describe the HRCT patterns of pulmonary tuberculosis in lung transplant recipients. Methods: From two hospitals in southern Brazil, we collected the following data on lung transplant recipients who developed pulmonary tuberculosis: gender; age; symptoms; the lung disease that led to transplantation; HRCT pattern; distribution of findings; time from transplantation to pulmonary tuberculosis; and mortality rate. The HRCT findings were classified as miliary nodules; cavitation and centrilobular nodules with a tree-in-bud pattern; ground-glass attenuation with consolidation; mediastinal lymph node enlargement; or pleural effusion. Results: We evaluated 402 lung transplant recipients, 19 of whom developed pulmonary tuberculosis after transplantation. Among those 19 patients, the most common HRCT patterns were ground-glass attenuation with consolidation (in 42%); cavitation and centrilobular nodules with a tree-in-bud pattern (in 31.5%); and mediastinal lymph node enlargement (in 15.7%). Among the patients with cavitation and centrilobular nodules with a tree-in-bud pattern, the distribution was within the upper lobes in 66.6%. No pleural effusion was observed. Despite treatment, one-year mortality was 47.3%. Conclusions: The predominant HRCT pattern was ground-glass attenuation with consolidation, followed by cavitation and centrilobular nodules with a tree-in-bud pattern. These findings are similar to those reported for immunocompetent patients with pulmonary tuberculosis and considerably different from those reported for AIDS patients with the same disease. (author)

  5. High-resolution computed tomography findings of pulmonary tuberculosis in lung transplant recipients.

    Science.gov (United States)

    Giacomelli, Irai Luis; Schuhmacher Neto, Roberto; Nin, Carlos Schuller; Cassano, Priscilla de Souza; Pereira, Marisa; Moreira, José da Silva; Nascimento, Douglas Zaione; Hochhegger, Bruno

    2017-01-01

    Respiratory infections constitute a major cause of morbidity and mortality in solid organ transplant recipients. The incidence of pulmonary tuberculosis is high among such patients. On imaging, tuberculosis has various presentations. Greater understanding of those presentations could reduce the impact of the disease by facilitating early diagnosis. Therefore, we attempted to describe the HRCT patterns of pulmonary tuberculosis in lung transplant recipients. From two hospitals in southern Brazil, we collected the following data on lung transplant recipients who developed pulmonary tuberculosis: gender; age; symptoms; the lung disease that led to transplantation; HRCT pattern; distribution of findings; time from transplantation to pulmonary tuberculosis; and mortality rate. The HRCT findings were classified as miliary nodules; cavitation and centrilobular nodules with a tree-in-bud pattern; ground-glass attenuation with consolidation; mediastinal lymph node enlargement; or pleural effusion. We evaluated 402 lung transplant recipients, 19 of whom developed pulmonary tuberculosis after transplantation. Among those 19 patients, the most common HRCT patterns were ground-glass attenuation with consolidation (in 42%); cavitation and centrilobular nodules with a tree-in-bud pattern (in 31.5%); and mediastinal lymph node enlargement (in 15.7%). Among the patients with cavitation and centrilobular nodules with a tree-in-bud pattern, the distribution was within the upper lobes in 66.6%. No pleural effusion was observed. Despite treatment, one-year mortality was 47.3%. The predominant HRCT pattern was ground-glass attenuation with consolidation, followed by cavitation and centrilobular nodules with a tree-in-bud pattern. These findings are similar to those reported for immunocompetent patients with pulmonary tuberculosis and considerably different from those reported for AIDS patients with the same disease.

  6. Magnetic resonance tomography of the heart

    Energy Technology Data Exchange (ETDEWEB)

    Tscholakoff, D.

    1987-01-01

    In this experimental study (canine heart) a variety of pathologic conditions of the myocardium were studied using ECG-triggered magnetic resonance imaging (MRI). The purpose of this study was to examine the MR appearance and the T/sub 2/ relaxation times of occlusive and reperfused myocardial infarcts, of hypertrophic cardiomyopathy and of cardiac transplants with and without acute cardiac allograft rejection. MR images were correlated with the results of histology and tissue water content. MRI identified normal myocardium with T/sub 2/ values of 38 (+-4.3) msec. Myocardial infarcts and acute allograft rejection had significant (p<0.05) longer T/sub 2/ values compared to normal myocardium. On the basis of T/sub 2/ relaxation times no further differentiation among different pathologic entities was possible. Therefore, it is necessary to include morphologic criteria such as myocardial wall thickness, cardiac chamber size and intracavitary blood flow signal in the interpretation of cardiac MR tomograms.

  7. Computed tomography findings of postoperative complications in lung transplantation; Achados tomograficos nas complicacoes pos-operatorias do transplante pulmonar

    Energy Technology Data Exchange (ETDEWEB)

    Hochhegger, Bruno; Irion, Klaus Loureiro; Marchiori, Edson; Bello, Rodrigo; Moreira, Jose; Camargo, Jose Jesus [Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS (Brazil). Postgraduate Program in Respiratory Sciences; Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Postgraduate Program in Radiological Sciences], e-mail: brunorgs@mail.ufsm.br

    2009-03-15

    Due to the increasing number and improved survival of lung transplant recipients, radiologists should be aware of the imaging features of the postoperative complications that can occur in such patients. The early treatment of complications is important for the long-term survival of lung transplant recipients. Frequently, HRCT plays a central role in the investigation of such complications. Early recognition of the signs of complications allows treatment to be initiated earlier, which improves survival. The aim of this pictorial review was to demonstrate the CT scan appearance of pulmonary complications such as reperfusion edema, acute rejection, infection, pulmonary thromboembolism, chronic rejection, bronchiolitis obliterans syndrome, cryptogenic organizing pneumonia, post transplant lymphoproliferative disorder, bronchial dehiscence and bronchial stenosis. (author)

  8. Predictive equations for lung volumes from computed tomography for size matching in pulmonary transplantation.

    Science.gov (United States)

    Konheim, Jeremy A; Kon, Zachary N; Pasrija, Chetan; Luo, Qingyang; Sanchez, Pablo G; Garcia, Jose P; Griffith, Bartley P; Jeudy, Jean

    2016-04-01

    Size matching for lung transplantation is widely accomplished using height comparisons between donors and recipients. This gross approximation allows for wide variation in lung size and, potentially, size mismatch. Three-dimensional computed tomography (3D-CT) volumetry comparisons could offer more accurate size matching. Although recipient CT scans are universally available, donor CT scans are rarely performed. Therefore, predicted donor lung volumes could be used for comparison to measured recipient lung volumes, but no such predictive equations exist. We aimed to use 3D-CT volumetry measurements from a normal patient population to generate equations for predicted total lung volume (pTLV), predicted right lung volume (pRLV), and predicted left lung volume (pLLV), for size-matching purposes. Chest CT scans of 400 normal patients were retrospectively evaluated. 3D-CT volumetry was performed to measure total lung volume, right lung volume, and left lung volume of each patient, and predictive equations were generated. The fitted model was tested in a separate group of 100 patients. The model was externally validated by comparison of total lung volume with total lung capacity from pulmonary function tests in a subset of those patients. Age, gender, height, and race were independent predictors of lung volume. In the test group, there were strong linear correlations between predicted and actual lung volumes measured by 3D-CT volumetry for pTLV (r = 0.72), pRLV (r = 0.72), and pLLV (r = 0.69). A strong linear correlation was also observed when comparing pTLV and total lung capacity (r = 0.82). We successfully created a predictive model for pTLV, pRLV, and pLLV. These may serve as reference standards and predict donor lung volume for size matching in lung transplantation. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  9. High-resolution computed tomography findings of pulmonary tuberculosis in lung transplant recipients

    Directory of Open Access Journals (Sweden)

    Irai Luis Giacomelli

    Full Text Available ABSTRACT Objective: Respiratory infections constitute a major cause of morbidity and mortality in solid organ transplant recipients. The incidence of pulmonary tuberculosis is high among such patients. On imaging, tuberculosis has various presentations. Greater understanding of those presentations could reduce the impact of the disease by facilitating early diagnosis. Therefore, we attempted to describe the HRCT patterns of pulmonary tuberculosis in lung transplant recipients. Methods: From two hospitals in southern Brazil, we collected the following data on lung transplant recipients who developed pulmonary tuberculosis: gender; age; symptoms; the lung disease that led to transplantation; HRCT pattern; distribution of findings; time from transplantation to pulmonary tuberculosis; and mortality rate. The HRCT findings were classified as miliary nodules; cavitation and centrilobular nodules with a tree-in-bud pattern; ground-glass attenuation with consolidation; mediastinal lymph node enlargement; or pleural effusion. Results: We evaluated 402 lung transplant recipients, 19 of whom developed pulmonary tuberculosis after transplantation. Among those 19 patients, the most common HRCT patterns were ground-glass attenuation with consolidation (in 42%; cavitation and centrilobular nodules with a tree-in-bud pattern (in 31.5%; and mediastinal lymph node enlargement (in 15.7%. Among the patients with cavitation and centrilobular nodules with a tree-in-bud pattern, the distribution was within the upper lobes in 66.6%. No pleural effusion was observed. Despite treatment, one-year mortality was 47.3%. Conclusions: The predominant HRCT pattern was ground-glass attenuation with consolidation, followed by cavitation and centrilobular nodules with a tree-in-bud pattern. These findings are similar to those reported for immunocompetent patients with pulmonary tuberculosis and considerably different from those reported for AIDS patients with the same disease.

  10. Optical coherence tomography of the living human kidney

    Directory of Open Access Journals (Sweden)

    Peter M. Andrews

    2014-03-01

    Full Text Available Acute tubular necrosis (ATN induced by ischemia is the most common insult to donor kidneys destined for transplantation. ATN results from swelling and subsequent damage to cells lining the kidney tubules. In this study, we demonstrate the capability of optical coherence tomography (OCT to image the renal microstructures of living human donor kidneys and potentially provide a measure to determine the extent of ATN. We also found that Doppler-based OCT (i.e., DOCT reveals renal blood flow dynamics that is another major factor which could relate to post-transplant renal function. All OCT/DOCT observations were performed in a noninvasive, sterile and timely manner on intact human kidneys both prior to (ex vivo and following (in vivo their transplantation. Our results indicate that this imaging model provides transplant surgeons with an objective visualization of the transplant kidneys prior and immediately post transplantation.

  11. MR tomography of tetralogy of Fallot. Kernspintomographie der Fallot-Tetralogie

    Energy Technology Data Exchange (ETDEWEB)

    Stark, P.; Agness, M.; Holshouser, B.; Hinshaw, D. Jr. (Loma Linda Univ., CA (USA). Dept. of Radiology)

    1991-08-01

    We present four patients with Tetralogy of Fallot, imaged with magnetic resonance. MRI is useful in clearly depicting the dilated ascending aorta, the infundibular stenosis, ventricular septal defect, right ventricular hypertrophy and dilated bronchial arteries. The pulmonary outflow tract can be visualized better with MR imaging than with ultrasound. (orig.).

  12. Skull base, orbits, temporal bone, and cranial nerves: anatomy on MR imaging.

    Science.gov (United States)

    Morani, Ajaykumar C; Ramani, Nisha S; Wesolowski, Jeffrey R

    2011-08-01

    Accurate delineation, diagnosis, and treatment planning of skull base lesions require knowledge of the complex anatomy of the skull base. Because the skull base cannot be directly evaluated, imaging is critical for the diagnosis and management of skull base diseases. Although computed tomography (CT) is excellent for outlining the bony detail, magnetic resonance (MR) imaging provides better soft tissue detail and is helpful for evaluating the adjacent meninges, brain parenchyma, and bone marrow of the skull base. Thus, CT and MR imaging are often used together for evaluating skull base lesions. This article focuses on the radiologic anatomy of the skull base pertinent to MR imaging evaluation. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Diagnosis of cardiac allograft rejection with MR imaging

    International Nuclear Information System (INIS)

    Soulen, R.L.; Fraser, C.D.; Hutchins, G.M.; Baumgartner, W.A.; Reitz, B.A.

    1987-01-01

    Serial MR images and endomyocardial biopsy specimens of heterotopic cervical cardiac allotransplants were obtained in six dogs during 2 weeks of immunosuppression followed by 1 week without such therapy. A surface coil and gated spin-echo technique were used. Myocardial intensity (MI) measurements and histopathologic interpretations were performed independently. All six dogs showed a decrease in MI between their first and second MR studies, while showing no rejection. One dog had no rejection and died; in five dogs studies gated to every other beat showed progressive increase in MI that correlated significantly with increasing rejection, though absolute MI values did not correlated with a specific biopsy score. Severe rejection also caused overt increase in myocardial mass. The MI in the early postoperative period may reflect reperfusion injury. Absolute intensity values cannot predict rejection. Serial studies in transplant patients may prove clinically useful

  14. Acute bone marrow edema of the hip: role of MR imaging

    International Nuclear Information System (INIS)

    Karantanas, Apostolos H.

    2007-01-01

    Acute bone marrow edema of the hip is a diagnostic challenge for both radiologists and clinicians. Marrow edema is often seen in patients with hip pain and restriction of motion. In patients with acute non-traumatic hip pain, whose radiographs are negative or inconclusive, MR imaging is the imaging study of choice. MR imaging is the most sensitive and specific imaging technique for detecting transient osteoporosis and osteonecrosis, as well as for detecting and staging fractures and microfractures. MR imaging is able to show marrow involvement in various inflammatory disorders and to diagnose reactive marrow edema from femoroacetabular impingment and greater trochanteric pain syndrome. In patients with septic arthritis, it may also depict associated marrow edema and suggest its reactive or infectious origin. For the neoplastic disorders, although plain radiographs should be the initial examination, MR imaging may follow for assessing extension to the surrounding soft tissues and/or associated pathologic fracture, facilitating thus the treatment planning. Computed tomography is more accurate compared with MR imaging in diagnosing intra-articular osteoid osteomas. (orig.)

  15. Acute bone marrow edema of the hip: role of MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Karantanas, Apostolos H. [University Hospital, Department of Radiology, Stavrakia, Heraklion, Crete (Greece)

    2007-09-15

    Acute bone marrow edema of the hip is a diagnostic challenge for both radiologists and clinicians. Marrow edema is often seen in patients with hip pain and restriction of motion. In patients with acute non-traumatic hip pain, whose radiographs are negative or inconclusive, MR imaging is the imaging study of choice. MR imaging is the most sensitive and specific imaging technique for detecting transient osteoporosis and osteonecrosis, as well as for detecting and staging fractures and microfractures. MR imaging is able to show marrow involvement in various inflammatory disorders and to diagnose reactive marrow edema from femoroacetabular impingment and greater trochanteric pain syndrome. In patients with septic arthritis, it may also depict associated marrow edema and suggest its reactive or infectious origin. For the neoplastic disorders, although plain radiographs should be the initial examination, MR imaging may follow for assessing extension to the surrounding soft tissues and/or associated pathologic fracture, facilitating thus the treatment planning. Computed tomography is more accurate compared with MR imaging in diagnosing intra-articular osteoid osteomas. (orig.)

  16. Liver remnant regeneration in donors after living donor liver transplantation. Long-term follow-up using CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Klink, T. [INSELSPITAL - Bern University Hospital (Switzerland). Diagnostic, Interventional, and Pediatric Radiology; University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Diagnostic and Interventional Radiology; Simon, P. [Merciful Brethren Hospital, Trier (Germany). Dept. of Radiology, Neuroradiology, Sonography and Nuclearmedicine; University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Diagnostic and Interventional Radiology; Knopp, C.; Ittrich, H.; Adam, G.; Koops, A. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Diagnostic and Interventional Radiology; Fischer, L. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Hepatobiliary Surgery and Transplant Surgery

    2014-06-15

    Purpose: To assess liver remnant volume regeneration and maintenance, and complications in the long-time follow-up of donors after living donor liver transplantation using CT and MRI. Materials and Methods: 47 donors with a mean age of 33.5 years who donated liver tissue for transplantation and who were available for follow-up imaging were included in this retrospective study. Contrast-enhanced CT and MR studies were acquired for routine follow-up. Two observers evaluated pre- and postoperative images regarding anatomy and pathological findings. Volumes were manually measured on contrast-enhanced images in the portal venous phase, and potential postoperative complications were documented. Pre- and postoperative liver volumes were compared for evaluating liver remnant regeneration. Results: 47 preoperative and 89 follow-up studies covered a period of 22.4 months (range: 1 - 84). After right liver lobe (RLL) donation, the mean liver remnant volume was 522.0 ml (± 144.0; 36.1%; n = 18), after left lateral section (LLS) donation 1,121.7 ml (± 212.8; 79.9%; n = 24), and after left liver lobe (LLL) donation 1,181.5 ml (± 279.5; 72.0%; n = 5). Twelve months after donation, the liver remnant volume were 87.3% (RLL; ± 11.8; n = 11), 95.0% (LS; ± 11.6; n = 18), and 80.1% (LLL; ± 2.0; n = 2 LLL) of the preoperative total liver volume. Rapid initial regeneration and maintenance at 80% of the preoperative liver volume were observed over the total follow-up period. Minor postoperative complications were found early in 4 patients. No severe or late complications or mortality occurred. Conclusion: Rapid regeneration of liver remnant volumes in all donors and volume maintenance over the long-term follow-up period of up to 84 months without severe or late complications are important observations for assessing the safety of LDLT donors. (orig.)

  17. Liver remnant regeneration in donors after living donor liver transplantation. Long-term follow-up using CT and MR imaging

    International Nuclear Information System (INIS)

    Klink, T.; University Medical Center Hamburg-Eppendorf, Hamburg; Simon, P.; University Medical Center Hamburg-Eppendorf, Hamburg; Knopp, C.; Ittrich, H.; Adam, G.; Koops, A.; Fischer, L.

    2014-01-01

    Purpose: To assess liver remnant volume regeneration and maintenance, and complications in the long-time follow-up of donors after living donor liver transplantation using CT and MRI. Materials and Methods: 47 donors with a mean age of 33.5 years who donated liver tissue for transplantation and who were available for follow-up imaging were included in this retrospective study. Contrast-enhanced CT and MR studies were acquired for routine follow-up. Two observers evaluated pre- and postoperative images regarding anatomy and pathological findings. Volumes were manually measured on contrast-enhanced images in the portal venous phase, and potential postoperative complications were documented. Pre- and postoperative liver volumes were compared for evaluating liver remnant regeneration. Results: 47 preoperative and 89 follow-up studies covered a period of 22.4 months (range: 1 - 84). After right liver lobe (RLL) donation, the mean liver remnant volume was 522.0 ml (± 144.0; 36.1%; n = 18), after left lateral section (LLS) donation 1,121.7 ml (± 212.8; 79.9%; n = 24), and after left liver lobe (LLL) donation 1,181.5 ml (± 279.5; 72.0%; n = 5). Twelve months after donation, the liver remnant volume were 87.3% (RLL; ± 11.8; n = 11), 95.0% (LS; ± 11.6; n = 18), and 80.1% (LLL; ± 2.0; n = 2 LLL) of the preoperative total liver volume. Rapid initial regeneration and maintenance at 80% of the preoperative liver volume were observed over the total follow-up period. Minor postoperative complications were found early in 4 patients. No severe or late complications or mortality occurred. Conclusion: Rapid regeneration of liver remnant volumes in all donors and volume maintenance over the long-term follow-up period of up to 84 months without severe or late complications are important observations for assessing the safety of LDLT donors. (orig.)

  18. Emphysema Is Common in Lungs of Cystic Fibrosis Lung Transplantation Patients: A Histopathological and Computed Tomography Study.

    Directory of Open Access Journals (Sweden)

    Onno M Mets

    Full Text Available Lung disease in cystic fibrosis (CF involves excessive inflammation, repetitive infections and development of bronchiectasis. Recently, literature on emphysema in CF has emerged, which might become an increasingly important disease component due to the increased life expectancy. The purpose of this study was to assess the presence and extent of emphysema in endstage CF lungs.In explanted lungs of 20 CF patients emphysema was semi-quantitatively assessed on histology specimens. Also, emphysema was automatically quantified on pre-transplantation computed tomography (CT using the percentage of voxels below -950 Houndfield Units and was visually scored on CT. The relation between emphysema extent, pre-transplantation lung function and age was determined.All CF patients showed emphysema on histological examination: 3/20 (15% showed mild, 15/20 (75% moderate and 2/20 (10% severe emphysema, defined as 0-20% emphysema, 20-50% emphysema and >50% emphysema in residual lung tissue, respectively. Visually upper lobe bullous emphysema was identified in 13/20 and more diffuse non-bullous emphysema in 18/20. Histology showed a significant correlation to quantified CT emphysema (p = 0.03 and visual emphysema score (p = 0.001. CT and visual emphysema extent were positively correlated with age (p = 0.045 and p = 0.04, respectively.In conclusion, this study both pathologically and radiologically confirms that emphysema is common in end-stage CF lungs, and is age related. Emphysema might become an increasingly important disease component in the aging CF population.

  19. Gemeinsam hilfreich oder einsam lästig? Beurteilung von praktikumsbegleitenden Weblogs von angehenden Lehrpersonen

    Directory of Open Access Journals (Sweden)

    Nives Egger

    2017-02-01

    Full Text Available Weblogs werden an Hochschulen vermehrt zur Unterstützung von Lern- und Reflexionsprozessen eingesetzt, in der Lehrer/innenbildung auch zunehmend während der berufspraktischen Ausbildung. Die Studierenden beurteilen den Einsatz von Weblogs jedoch unterschiedlich. Dabei ist wenig bekannt, welchen Einfluss die Vergabe und das Erhalten von Peerfeedback auf den Beurteilungsprozess von praktikumsbegleitenden Weblogs sowie auf den Umfang von Blogpostings haben. Im folgenden Beitrag wird dieser Frage mittels einer Befragung von 74 angehenden Lehrpersonen nachgegangen, die praktikumsbegleitende Weblogs mit oder ohne Peerfeedback nutzten, um über herausfordernde Ereignisse im Praktikum zu reflektieren. Die Ergebnisse zeigen, dass Studierende, die Peerfeedback erhielten und andere Blogbeiträge kommentierten, den Weblogeinsatz nützlicher einschätzen sowie eine höhere Motivation und positivere Einstellung gegenüber den Einsatz von Weblogs aufweisen als Studierende, die ohne Peerfeedback bloggen. Keinen Einfluss hat Peerfeedback auf den Umfang der Blogbeiträge und auf die dafür aufgewendete Zeit.

  20. MR imaging of the knee following cruciate ligament reconstruction and meniscal surgery; MRT des Kniegelenks nach Kreuzband- und Meniskusoperationen

    Energy Technology Data Exchange (ETDEWEB)

    Woertler, K. [Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Inst. fuer Roentgendiagnostik

    2009-03-15

    Due to the increasing number of surgical procedures performed on the knee, MR imaging of the postoperative knee has gained more and more importance. For the evaluation of anterior cruciate ligament grafts and postoperative menisci, basic knowledge of surgical techniques is essential in order to differentiate normal postoperative findings from transplant failure, retears, and complications. This article reviews technical aspects of MR imaging following knee surgery, basic principles of operative techniques for anterior cruciate ligament reconstruction and therapy of meniscal tears, normal postoperative findings, MR imaging criteria for recurrent lesions, and findings with typical complications. (orig.)

  1. Clinical characteristics and computed tomography findings of pulmonary toxoplasmosis after hematopoietic stem cell transplantation.

    Science.gov (United States)

    Sumi, Masahiko; Norose, Kazumi; Hikosaka, Kenji; Kaiume, Hiroko; Takeda, Wataru; Kirihara, Takehiko; Kurihara, Taro; Sato, Keijiro; Ueki, Toshimitsu; Hiroshima, Yuki; Kuraishi, Hiroshi; Watanabe, Masahide; Kobayashi, Hikaru

    2016-12-01

    The prognosis of pulmonary toxoplasmosis, including disseminated toxoplasmosis involving the lungs, following hematopoietic stem cell transplantation (HSCT) is extremely poor due to the difficulties associated with early diagnosis and the rapidly progressive deterioration of multiorgan function. In our institution, we identified nine cases of toxoplasmosis, representing incidences of 2.2 and 19.6 % among all HSCT recipients and seropositive HSCT recipients, respectively. Of the patients with toxoplasmosis, six had pulmonary toxoplasmosis. Chest computed tomography (CT) findings revealed centrilobular, patchy ground-glass opacities (n = 3), diffuse ground-glass opacities (n = 2), ground-glass opacities with septal thickening (n = 1), and marked pleural effusion (n = 1). All cases died, except for one with suspected pulmonary toxoplasmosis who was diagnosed by a polymerase chain reaction assay 2 days after the onset of symptoms. In pulmonary toxoplasmosis, CT findings are non-specific and may mimic pulmonary congestion, atypical pneumonia, viral pneumonitis, and bronchopneumonia. Early diagnosis and treatment is crucial for overcoming this serious infectious complication. Pulmonary toxoplasmosis should be considered during differential diagnosis in a recipient with otherwise unexplained signs of infection and CT findings with ground-glass opacities, regardless of the distribution.

  2. Entwicklung und Anwendung von Methoden zur Bestimmung von Selen-Spezies in human-biologischem Material

    OpenAIRE

    Jäger, Thomas

    2014-01-01

    Selen ist essentieller Bestandteil von mehr als 25 physiologisch wichtigen menschlichen Enzymen. Der tägliche Bedarf wird überwiegend in Form von organischen Selenverbindungen wie Selenmethionin oder Selenocystein aus der Nahrung aufgenommen. Weitere Expositionswege sind die Einnahme von Nahrungsergänzungsmitteln zur Selensupplementation sowie die inhalative oder dermale Aufnahme von in erster Linie anorganischen Selenverbindungen oder elementarem Selen an Arbeitsplätzen der Selen-verarbeiten...

  3. Aggregation und Management von Metadaten im Kontext von Europeana

    Directory of Open Access Journals (Sweden)

    Gerda Koch

    2017-09-01

    Full Text Available Mit dem In-Beziehung-Setzen und Verlinken von Daten im Internet wird der Weg zur Umsetzung des semantischen Webs geebnet. Erst die semantische Verbindung von heterogenen Datenbeständen ermöglicht übergreifende Suchvorgänge und späteres „Machine Learning“. Im Artikel werden die Aktivitäten der Europäischen Digitalen Bibliothek im Bereich des Metadatenmanagements und der semantischen Verlinkung von Daten skizziert. Dabei wird einerseits ein kurzer Überblick zu aktuellen Forschungsschwerpunkten und Umsetzungsstrategien gegeben, und darüber hinaus werden einzelne Projekte und maßgeschneiderte Serviceangebote für naturhistorische Daten, regionale Kultureinrichtungen und Audiosammlungen beschrieben.

  4. Von der Medienwirkungsbehauptung zur erziehungswissenschaftlichen Medienrezeptionsforschung. Vorschlag zur Analyse von Filmkommunikaten

    Directory of Open Access Journals (Sweden)

    Barbara Drinck

    2001-04-01

    Full Text Available Im Hinblick auf die Erforschung spezifischer Zusammenhänge von Medienkonsum und der Herausbildung von Einstellungen und Handlungen wird eine konstruktivistische Theorieorientierung plausibilisiert, indem zunächst auf den Stand der Medienwirkungsforschung eingegangen und vor dem Hintergrund einer begründeten Kritik des Wirkungsverständnisses auf die Notwendigkeit einer medienrezeptionswissenschaftlichen Forschungsalternative hingewiesen wird. Weiterhin wird der Stand der (erziehungswissenschaftlichen Medienrezeptionsforschung erörtert. Sodann werden Elemente einer konstruktivistischen Methodologie von Medienrezeptionsforschung beschrieben, die am Beispiel der Rezeption von Filmen konkretisiert werden. Dabei wird das Konzept des Kommunikates (S.J. Schmidt als Ausgangspunkt genommen, ein Vorschlag für eine Beschreibungssprache für (Film- Kommunikate entwickelt und eine Adaption des Ansatzes filmischer Narration zur Sprache gebracht.

  5. Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?

    Directory of Open Access Journals (Sweden)

    Markiet Karolina

    2011-04-01

    Full Text Available Abstract Background Cavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other benign focal lesions. The purpose of this study is to evaluate whether diagnostic accuracy of magnetic resonance imaging (MRI of hepatic hemangiomas, showing atypical pattern on US, improves with the use of Gd-BOPTA in comparison with contrast-enhanced multi-phase computed tomography (CT. Methods 178 consecutive patients with ambiguous hepatic masses showing atypical hyperechoic pattern on grey-scale US, underwent unenhanced and contrast-enhanced multi-phase multi-detector CT and MR (1.5T with the use of liver-specific contrast medium gadobenate dimeglumine (Gd-BOPTA. After intravenous contrast administration arterial (HAP, venous-portal (PVP, equilibrium phases (EP both in CT and MR and additionally hepatobiliary phase (HBP in MR were obtained. 398 lesions have been detected including 99 hemangiomas and 299 other lesions. Results In non-enhanced MDCT examination detection of hemangiomas was characterized by sensitivity of 76%, specificity of 90%, PPV of 71%, NPV of 92% and accuracy of 86%. Non-enhanced MR examination showed sensitivity of 98%, specificity of 99%, PPV of 99%, NPV of 99% and accuracy of 99%. After intravenous administration of contrast medium in MR the mentioned above parameters did not increase significantly. Conclusion Gd-BOPTA-enhanced MR in comparison with unenhanced MRI does not improve diagnostic accuracy in discriminating hemangiomas that show non-specific appearance in ultrasound examination. Unenhanced MR as a method of choice should directly follow US in course of diagnostic algorithm in differentiation of hemangiomas from other liver tumors.

  6. Visualization of pulmonary vein stenosis after radio frequency ablation for treatment of atrial fibrillation using multidetector computed tomography with retrospective gating; Darstellung von Pulmonalvenenstenosen nach Radiofrequenzablation zur Behandlung von Vorhofflimmern unter Verwendung der Multidetektor Computertomographie mit retrospektivem Gating

    Energy Technology Data Exchange (ETDEWEB)

    Trabold, T.; Kuettner, A.; Heuschmid, M.; Kopp, A.F.; Claussen, C.D. [Radiologische Klinik, Abt. fuer Radiologische Diagnostik, Univ. Tuebingen (Germany); Burgstahler, C.; Mewis, C.; Schroeder, S.; Kuehlkamp, V. [Medizinische Klinik III, Abt. fuer Kardiologie, Univ. Tuebingen (Germany)

    2003-01-01

    Purpose: With the number of radio frequency ablations (RFA) for treatment of chronic atrial fibrillation increasing, the diagnostic evaluation for RFA associated pulmonary vein stenosis is getting more important. This study investigates the feasibility of the visualization of pulmonary vein stenosis using non-invasive multidetector computed tomography. Materials and Methods: Twenty-eight patients were examined following RFA-treatment. A 4-slice (20 patients) and a 16-slice (8 patients) multidetector CT scanner (SOMATOM Volume Zoom and Sensation 16, Siemens, Forchheim, Germany) with retrospective gating was used to assess the pulmonary veins. Lesion severity was determined on a semi-quantitative scale (< 30%, 30 - 50%, > 50%). Results: CT was performed without any complications in all patients. Diagnostic image quality could be obtained in all examinations. The pulmonary veins showed lesions < 30% in four patients, lesions of 30 - 50% in five patients and a stenosis > 50% in one patient. Eighteen patients showed no lesions. Conclusion: Multidetector CT of the pulmonary veins seems to be able to visualize high-grade and low-grade lesions, but larger catheter-controlled studies are needed for further assessment of the diagnostic accuracy and clinical reliability of this noninvasive method. (orig.) [German] Ziel: Mit steigender Anzahl von Radiofrequenzablationen (RFA) zur Behandlung des chronischen Vorhofflimmerns wird die Diagnostik von RFA assoziierten Pulmonalvenenstenosen zunehmend wichtiger. Ziel dieser Studie war es, die Moeglichkeit der Darstellung von Pulmonalvenenstenosen mittels der nichtinvasiven Multidetektor-Computertomographie zu untersuchen. Material und Methoden: 28 Patienten wurden im Anschluss an eine RFA-Behandlung untersucht. Die Untersuchung wurde an einem 4-Zeilen- (20 Patienten) bzw. 16-Zeilen- (8 Patienten) Multidetektor-CT (SOMATOM Volume Zoom bzw. Sensation 16, Siemens, Forchheim, Germany) mit retrospektivem Gating durchgefuehrt. Der

  7. Quantitative analysis of contrast enhancement of transplanted kidneys under computed tomography

    International Nuclear Information System (INIS)

    Fujita, Tamio; Asano, Haruyoshi; Yanaoka, Masanori; Moriguchi, Ryuichiro; Okishio, Norihiko

    1981-01-01

    Using Hitachi CT-3, the changes in CT numbers of the kidney were calculated in 10 normal and 12 transplanted kidneys. Two mililiters per kg of meglumine diatrizoate (Angiografin) was given intravenously in bolus fashion. Kidneys were scanned before injection, at termination of injection and correctly 10 minutes after injection. In control group, the CT numbers of the cortex, the medulla and the aorta showed rapid increase after contrast administration. Ten minutes after administration of medium, the CT numbers of the medulla remained a little higher than the cortex, though that of the aorta showed rapid decrease. In contrast to control group, in transplanted kidneys the CT numbers of the cortex and medulla showed less increase than the control group just after contrast administration. Moreover, in the recipients who have had good graft function the CT numbers of the cortex and medulla showed gradual increase, in the recipients who have had poor graft function the CT numbers showed gradual decrease 10 minutes after injection. Enhancing indices calculated from the formula: CT numbers 10 minutes after contrast enhancement CT numbers before contrast enhancement were inversely proportional to the serum creatinine. These results lead to the conclusion that the CT scans employing contrast enhancement method after kidney transplantation has the diagnostic value of graft function in addition to diagnostic usefulness for post-transplantation complications such as hematoma, urinoma or lymphocele. (author)

  8. Kinematic CT and MR imaging of the patellofemoral joint

    International Nuclear Information System (INIS)

    Muhle, C.; Brossmann, J.; Heller, M.

    1999-01-01

    Anterior knee pain is a frequently encountered orthopedic symptom and is often associated with patellofemoral malalignment, which may cause chondromalacia of the patella. The difficulty in determining the patellar position between 0 and 30 of knee flexion with a conventional axial radiographic examination is well known. The introduction of computed tomography (CT) and magnetic resonance (MR) imaging for the diagnosis of knee joint abnormalities has enabled assessment of the patellar position in this critical range. More recently, emphasis has been placed on dynamic visualization of patellar motion to detect an abnormal tracking pattern. The important influence of the quadriceps muscle on the patellar tracking pattern is well known and has been examined during active knee extension by the use of ultrafast CT, and motion-triggered and ultrafast MR imaging. This article provides an overview of the current status of kinematic CT and MR imaging in the diagnosis of patellofemoral alignment, its clinical implications, and future directions. (orig.)

  9. Kinematic CT and MR imaging of the patellofemoral joint

    Energy Technology Data Exchange (ETDEWEB)

    Muhle, C.; Brossmann, J.; Heller, M. [Klinik fuer Radiologische Diagnostik, Christian-Albrechts-Universitaet, Kiel (Germany)

    1999-04-01

    Anterior knee pain is a frequently encountered orthopedic symptom and is often associated with patellofemoral malalignment, which may cause chondromalacia of the patella. The difficulty in determining the patellar position between 0 and 30 of knee flexion with a conventional axial radiographic examination is well known. The introduction of computed tomography (CT) and magnetic resonance (MR) imaging for the diagnosis of knee joint abnormalities has enabled assessment of the patellar position in this critical range. More recently, emphasis has been placed on dynamic visualization of patellar motion to detect an abnormal tracking pattern. The important influence of the quadriceps muscle on the patellar tracking pattern is well known and has been examined during active knee extension by the use of ultrafast CT, and motion-triggered and ultrafast MR imaging. This article provides an overview of the current status of kinematic CT and MR imaging in the diagnosis of patellofemoral alignment, its clinical implications, and future directions. (orig.) With 13 figs., 5 tabs., 47 refs.

  10. MR imaging of the normal pancreas

    International Nuclear Information System (INIS)

    Itoh, Hisao; Takahashi, Norio; Uchida, Yoshie; Nakayama, Gen; Bito, Kaoru; Haba, Hirotsugu; Kawamura, Masashi; Kataoka, Masaaki; Hamamoto, Ken.

    1989-01-01

    To evaluate current 1.5-T MR imaging with respiratory ordered phase encoding (ROPE) technique in the identification of pancreatic contour and main pancreatic duct, 100 normal subjects examined with spin echo technique including transaxial scans of T 1 -WI,T 2 -WI, and proton density (PD)-WI were reviewed. The results of MR imaging were then compared with computed tomography (CT). Pancreatic contour was divided into 3 parts; head, body, and tail. T 1 -WI was the best pulse sequence in describing pancreas and the rates of specific identification of head, body, and tail were 69%, 97%, and 92%, respectively. While these rates were 62%, 90%, and 92% with plain CT and 69%, 94%, and 94% with contrast-enhanced CT, respectively. A combination of MR imaging and CT yielded better rates of identification. The main pancreatic duct was visible in 44% as a low intensity line on T 1 -WI and in 16% on plain CT. Dorsal to pancreas, all of the major vessels were seen in every patients. Ventrally, retroperitoneal fat was important, however, it was not a limiting factor. When respiratory compensation using ROPE functioned well, it was possible to differentiate bowel from pancreas in patients with sparse fat because signal intensity of the pancreas tended to be higher than that of gastrointestinal wall and its contents on T 1 -WI. Current MR imaging seemed to be a complementary method with CT in the identification of the pancreas. (author)

  11. Local recurrence of rectal cancer: MR imaging before and after oral superparamagnetic particles vs contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Blomqvist, L.; Ohlsen, H.; Holm, T.

    2000-01-01

    The aim of this study was to compare three imaging strategies for the diagnosis of local recurrence of rectal cancer: (a) MR imaging; (b) MR imaging after administration of enteral superparamagnetic particles (Ferristene); and (c) contrast-enhanced CT. Seventeen patients with previous surgery for rectal cancer were examined, 12 patients with local tumour recurrence in the pelvis and 5 patients with postoperative changes. Pelvic multi-coil MR imaging before and after oral administration of superparamagnetic contrast medium [Abdoscan (Ferristene USAN), Nycomed-Amersham, Lidingoe, Sweden] as well as abdominal and pelvic CT was performed in all patients. The examinations were independently evaluated by three different radiologists. The general effect of the oral MR contrast medium, the delineation of normal and pathological structures as well as confidence in the diagnosis were registered on a visual analog scale (VAS). The diagnosis according to MR before and after oral contrast medium, and CT, was compared, in 16 patients, with the final diagnosis which was verified by biopsy (n = 3), surgery (n = 6), clinical follow-up (n = 4) and by follow-up with MR or CT (n = 3). No significant improvement in MR image quality was found after enteral contrast medium. The post-contrast MR diagnosis was not changed in any of the patients. The diagnosis on MR correlated with the final diagnosis in 12 of 16 patients (sensitivity 91 %, accuracy 62 %) and the diagnosis on CT in 11 of 16 patients (sensitivity 82 %, accuracy 56 %). The radiologists' ''confidence'' in the diagnosis and the degree of accordance with the final diagnosis did not score higher on MR after than before oral contrast administration; however, the accordance with the final diagnosis scored better on MR than on CT. No advantages of orally administered superparamagnetic contrast medium were observed in the examined patient group. Magnetic resonance is preferable to CT in diagnosing local tumour recurrence. (orig.)

  12. Soft tissue sarcoma: how can posttreatment alterations be distinguished from recurrences?; Weichteilsarkome: Wie lassen sich posttherapeutische Veraenderungen von Rezidiven unterscheiden

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, I.M. [Universitaetsklinik fuer Radiologie und Nuklearmedizin, Abteilung fuer Neuroradiologie und Muskuloskeletale Radiologie, Wien (Austria); Grieser, T. [Klinikum Augsburg, Klinik fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Augsburg (Germany)

    2017-11-15

    The recognition of recurrent soft tissue sarcomas and the differentiation from post-treatment alterations is complex. This article aims to assist the clinical radiologist in the systematic evaluation of local follow-up imaging in soft tissue sarcoma patients. Soft tissue sarcomas encompass multiple entities with different recurrence rates and follow-up intervals. Approved and up to date recommendations are provided, including imaging techniques. The past medical history of the patient, the clinical situation and previous therapies should be known in detail, including surgery, radiation therapy and chemotherapy. Previous imaging results should be consulted, if available. This article describes the time-dependent imaging spectrum of local post-therapeutic as well as local treatment-related complications. These include early complications, such as seromas, hematomas and infections, as well as late complications, including edema, fibrosis and joint stiffness, and also inflammatory pseudotumors, which may occur after variable time intervals. The imaging appearance of local recurrent and radiation-associated sarcoma are elucidated. In particular, magnetic resonance imaging (MRI) criteria are provided, which may help in differentiating post-therapeutic alterations from recurrent soft tissue sarcomas. (orig.) [German] Die Erkennung von Weichteilsarkomrezidiven und ihre Differenzierung von posttherapeutischen Veraenderungen sind komplex. Der Beitrag soll dem klinisch taetigen Radiologen helfen, lokale Nachkontrollen systematisch zu beurteilen. Voraussetzungen sind einerseits die genaue Kenntnis der klinischen und therapeutischen Anamnese und der aktuellen klinischen Situation sowie andererseits eine adaequate Untersuchungstechnik, fuer die Empfehlungen gegeben werden, und ein Vergleich mit der initialen Bildgebung. Der Beitrag gibt einen Ueberblick ueber Rezidivhaeufigkeiten und Therapiemodalitaeten wie der Operation, Bestrahlung und Chemotherapie. Er beschreibt das MR

  13. Reproducibility of MR-based Attenuation Maps in PET/MRI and the Impact on PET Quantification in Lung Cancer

    DEFF Research Database (Denmark)

    Olin, Anders; Ladefoged, Claes N; Langer, Natasha H

    2018-01-01

    AIM: Quantitative positron emission tomography/magnetic resonance imaging (PET/MRI) is dependent upon reliable and reproducible MR-based attenuation correction (MR-AC). In this study we evaluated the quality of current vendor-provided thoracic MR-AC maps, and further investigated...... affecting the reproducibility of PET/MRI. This, in combination with other well-known sources of error associated with PET/MRI examinations, leads to inconsistent SUV measurements in serial studies and follow-up scenarios, which may affect the reliability of therapy response assessment. A thorough visual...

  14. Giant cell tumor of soft tissue: a case report with emphasis on MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Moon Young; Jee, Won-Hee [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, School of Medicine, Seocho-gu, Seoul (Korea, Republic of); Jung, Chan Kwon [The Catholic University of Korea, Department of Pathology, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of); Yoo, Ie Ryung [The Catholic University of Korea, Department of Nuclear Medicine, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of); Chung, Yang-Guk [The Catholic University of Korea, Department of Orthopedic Surgery, Seoul St. Mary' s Hospital, College of Medicine, Seocho-gu, Seoul (Korea, Republic of)

    2015-04-03

    Giant cell tumor of soft tissue is a rare neoplasm, histologically resembling giant cell tumor of bone. In this report, we describe a deep and solid giant cell tumor of soft tissue interpreted as a benign soft tissue tumor based on magnetic resonance (MR) findings with hypointense to intermediate signals on T2-weighted images and impeded diffusivity (water movement) on diffusion-weighted imaging (DWI), which could suggest a giant-cell-containing benign soft tissue tumor, despite the malignancy suggested by {sup 18}F-fluorodeoxyglucose positron emission tomography-computed tomography in a 35-year-old male. To our knowledge, this report introduces the first deep, solid giant cell tumor of soft tissue with MR features of a giant-cell-containing benign soft tissue tumor, despite the malignancy-mimicking findings on {sup 18}F-FDG PET-CT. (orig.)

  15. Neues über das Tertiär von Java und die mesozoischen Schichten von West-Borneo

    NARCIS (Netherlands)

    Martin, K.

    1888-01-01

    Die Monographie, welche unter dem Titel Die Fossilien von Java herausgegeben wird ¹), ist so weit fortgeschritten, dass sich aus den in ihr beschriebenen Gastropoden bereits eine Anzahl von Schlussfolgerungen ableiten lässt, welche für die in Bearbeitung begriffene, geologische Karte von Java von

  16. Analytik von Minorlipiden: Ferulasäureester von Phytosterolen (gamma-Oryzanol) in Reis

    OpenAIRE

    Miller, Andreas

    2005-01-01

    Ferulasäureestern von Phytosterolen (γ-Oryzanol) werden antioxidative und cholesterinsenkende Eigenschaften zugeschrieben. Bisher beschriebene Methoden zur Analytik von γ-Oryzanol in Reis erforderten eine aufwendige Aufreinigung des Probenextrakts. In dieser Arbeit wurde basierend auf der on-line LC-GC eine Methode entwickelt, die die simultane Bestimmung von γ-Oryzanol-Gehalt und Sterylferulat-Verteilung ohne Aufreinigung des Probenextrakts erlaubt. Mit Hilfe der Technik wurden die natürlich...

  17. Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer; MRT-gezielte interventionelle Verfahren zur Abklaerung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Schernthaner, M.; Helbich, T.H.; Fueger, B.J.; Memarsadeghi, M.; Stiglbauer, A.; Linhart, H.G.; Doan, A.; Pinker, K.; Brader, P. [Medizinische Universitaet Wien, Univ.-Klinik fuer Radiodiagnostik, Division fuer Molekulare und Gender-Bildgebung, Wien (Austria); Margreiter, M. [Medizinische Universitaet Wien, Univ.-Klinik fuer Urologie, Wien (Austria)

    2011-11-15

    In recent years magnetic resonance imaging (MRI) has been increasingly established in the diagnosis of prostate cancer in addition to transrectal ultrasonography (TRUS). The use of T2-weighted imaging allows an exact delineation of the zonal anatomy of the prostate and its surrounding structures. Other MR imaging tools, such as dynamic contrast-enhanced T1-weighted imaging or diffusion-weighted imaging allow an inference of the biochemical characteristics (multiparametric MRI). Prostate cancer, which could only be diagnosed using MR imaging or lesions suspected as being prostate cancer, which are localized in the anterior aspect of the prostate and were missed with repetitive TRUS biopsy, need to undergo MR guided biopsy. Recent studies have shown a good correlation between MR imaging and histopathology of specimens collected by MR-guided biopsy. Improved lesion targeting is therefore possible with MR-guided biopsy. So far data suggest that MR-guided biopsy of the prostate is a promising alternative diagnostic tool to TRUS-guided biopsy. (orig.) [German] Neben dem transrektalen Ultraschall (TRUS) hat sich in den letzten Jahren die MRT als nichtinvasive Methode zur Bildgebung von Prostatatumoren etabliert. Mittels T2-gewichteter Sequenzen ist eine exakte anatomische Darstellung der Prostata und ihrer umliegenden Strukturen moeglich. Andere MRT-Techniken ermoeglichen Rueckschluesse auf das biologische Verhalten des Tumors: dynamische kontrastmittelverstaerkte T1-gewichtete Sequenzen zur Darstellung der Angiogenese, diffusionsgewichtete Aufnahmen zur Beurteilung der Zelldichte und die Spektroskopie zur Bestimmung von Gewebemetaboliten wie Cholin und Kreatin (multiparametrische Bildgebung). Prostatatumoren, die nur mittels MRT nachweisbar sind oder verdaechtige Tumoren, die hauptsaechlich anterior in der Prostata lokalisiert sind und in wiederholten TRUS-gezielten Biopsien verfehlt wurden, benoetigen eine MRT-gezielte Biopsie zur Diagnosesicherung. Die bisherigen

  18. PET/MR in invasive ductal breast cancer: correlation between imaging markers and histological phenotype.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Horn, Gary Lloyd; Signore, Alberto; Iannace, Carlo; Lepore, Maria; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Lehman, Constance; Salvatore, Marco; Soricelli, Andrea; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-03-28

    Differences in genetics and receptor expression (phenotypes) of invasive ductal breast cancer (IDC) impact on prognosis and treatment response. Immunohistochemistry (IHC), the most used technique for IDC phenotyping, has some limitations including its invasiveness. We explored the possibility of contrast-enhanced positron emission tomography magnetic resonance (CE-FDG PET/MR) to discriminate IDC phenotypes. 21 IDC patients with IHC assessment of oestrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor-2 (HER2), and antigen Ki-67 (Ki67) underwent CE-FDG PET/MR. Magnetic resonance-perfusion biomarkers, apparent diffusion coefficient (ADC), and standard uptake value (SUV) were compared with IHC markers and phenotypes, using a Student's t-test and one-way ANOVA. ER/PR- tumours demonstrated higher Kep mean and SUV max than ER or PR+ tumours. HER2- tumours displayed higher ADC mean , Kep mean , and SUV max than HER2+tumours. Only ADC mean discriminated Ki67⩽14% tumours (lower ADC mean ) from Ki67>14% tumours. PET/MR biomarkers correlated with IHC phenotype in 13 out of 21 patients (62%; P=0.001). Positron emission tomography magnetic resonance might non-invasively help discriminate IDC phenotypes, helping to optimise individual therapy options.

  19. Creutzfeldt-Jakob disease. What is the role of magnetic resonance tomography?; Creutzfeldt-Jakob-Krankheit. Welche Rolle spielt die MR-Tomographie?

    Energy Technology Data Exchange (ETDEWEB)

    Kujat, C. [Inst. fuer Neuroradiologie der Univ. des Saarlandes, Homburg (Germany); Hagen, T. [Inst. fuer Neuroradiologie der Univ. des Saarlandes, Homburg (Germany); Feiden, W. [Abt. fuer Neuropathologie der Univ. des Saarlandes, Homburg (Germany)

    1995-11-01

    We report three patients with histologically confirmed CJD and confirm that MRI is a valuable tool for the diagnosis of this disease. (orig./MG) [Deutsch] Anhand der MRT-Ergebnisse von 3 Patienten mit histologisch gesicherter CJD und einer Literaturrecherche wird untersucht, ob die MRT einen Beitrag zur Diagnostik der CJD leisten kann. (orig./MG)

  20. Static-dynamic MR urography. Comparison with excretory urography and scintigraphy in experimentally induced urinary tract obstruction (UTO); Statisch-dynamische MR-Urographie. Vergleich mit Ausscheidungsurographie und Szintigraphie bei experimentell induzierter Harntransportstoerung (HTS)

    Energy Technology Data Exchange (ETDEWEB)

    Rohrschneider, W.K.; Wunsch, R.; Troeger, J. [Paediatrische Radiologie, Univ. Heidelberg (Germany); Hoffend, J. [Nuklearmedizinische Klinik, Univ. Heidelberg (Germany); Becker, K. [Inst. fuer Versuchstierkunde, Univ. Heidelberg (Germany); Darge, K.; Clorius, J.H. [Kooperationseinheit Nuklearmedizin, Deutsches Krebsforschungszentrum, Heidelberg (Germany); Kooijman, H. [Philips Medizin-Systeme, Hamburg (Germany)

    2001-02-01

    ermoeglichte die vollstaendige Abbildung des Harntraktes bei allen Kontrolltieren, bei operierten Tieren wurde die Stenose immer korrekt lokalisiert. Die MRU war der AUG in 36 von 43 Vergleichsstudien qualitativ ueberlegen. Die Kalkulation der seitengetrennten Nierenfunktion aus parenchymalen Renogrammen und die Abschaetzung des Harnabflusses aus Gesamt-Nieren-Renogrammen ergaben eine hochsignifikante Uebereinstimmung der MRU mit der DNS. Schlussfolgerung: Die statisch-dynamische MR-Urographie erlaubt die exzellente Darstellung tierexperimentell induzierter Harntransportstoerungen sowie die zuverlaessige Bestimmung von Nierenfunktion und Harnabfluss. Vorteile der Methode sind die fehlende Strahlenbelastung und die direkte funktionell-morphologische Korrelation. (orig.)

  1. Intra-axial brain tumors in adults. On the basis of the 2016 WHO classification; Intraaxiale Hirntumoren des Erwachsenenalters. Auf der Basis der WHO-Klassifizierung 2016

    Energy Technology Data Exchange (ETDEWEB)

    Peitgen, N.; Papanagiotou, P. [Klinikum Bremen-Mitte/Bremen-Ost, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Bremen (Germany)

    2017-09-15

    The influence of the World Health Organization (WHO) classification from 2016 on the radiological diagnosis for tumors of the central nervous system (CNS) in adults. Computed tomography (CT), magnetic resonance imaging (MRI) and MR spectroscopy. In order to come as close as possible to the correct diagnosis of CNS tumors, MRI is the long-standing accepted method of choice that can in some cases be supported by the use of CT to demonstrate calcification or bone destruction. In individual cases MRI spectroscopy can be helpful for the differentiation between neoplasms and inflammatory lesions or surveillance of tumor therapy, just as perfusion, which is not discussed in this article. (orig.) [German] Einfluss der WHO-Klassifikation von 2016 fuer ZNS-Tumoren auf die radiologische Befunderstellung fuer ZNS-Tumoren des Erwachsenenalters. CT, MRT, MR-Spektroskopie. Um sich der korrekten Diagnose bzgl. eines ZNS-Tumors bestmoeglich zu naehern, ist die MRT das akzeptierte Standardverfahren, die in Einzelfaellen durch eine CT ergaenzt werden kann, wenn Verkalkungen oder knoecherne Arrosionen dargestellt werden sollen. Eine MR-Spektroskopie kann in Einzelfaellen zur Differenzierung von Neoplasien und entzuendlichen Veraenderungen oder Tumorverlaufskontrollen unter Therapie hilfreich sein, ebenso wie die Perfusion, auf die in diesem Artikel nicht eingegangen wird. (orig.)

  2. CT and MR imaging characteristics of infantile hepatic hemangioendothelioma

    International Nuclear Information System (INIS)

    Feng Shiting; Chan Tao; Ching, A.S.C.; Sun Canhui; Guo Huanyi; Fan Miao; Meng Quanfei; Li Ziping

    2010-01-01

    Aim: This study aims to analyze computed tomography (CT) and magnetic resonance (MR) imaging features of infantile hepatic hemangioendotheliomas before and after treatment. Materials and methods: CT and MR examinations of seven infants with biopsy proven hepatic hemangioendotheliomas were retrospectively analyzed. The distribution, number, size, imaging appearance, enhancement pattern and post-treatment changes of the tumors were evaluated. Results: A total of 153 hepatic hemangioendotheliomas were detected on CT (111) and MR (42) imaging. In six infants, 109/111 (98.2%) tumors were hypodense and 2/111 (1.8%) lesions contained calcification on unenhanced CT. On MR imaging, all 42 lesions in one infant were heterogeneously T1-hypointense and T2-hyperintense compared to the normal liver parenchyma. Contrast-enhanced CT and MRI showed peripheral rim (51.6%), uniform (48.4%), fibrillary (33.3%), and nodular (28.8%) contrast enhancement in the hepatic arterial phase. Homogeneous (100%), rim (98.2%) and mixed enhancement patterns were noted in tumors 2.0 cm and 1.0-2.0 cm in diameter respectively in the hepatic arterial phase. In three patients who underwent steroid therapy, follow-up CT examination demonstrated tumor size reduction and increased intra-tumoral calcification in two patients. Conclusion: Infantile hepatic hemangioendotheliomas show some typical imaging features and size-dependent pattern of contrast enhancement on CT and MR imaging, which allow accurate imaging diagnosis and post-treatment evaluation.

  3. PET-Studies in parkinson's disease; Untersuchungen mit der Positronen-Emissions-Tomographie (PET) bei Patienten mit Morbus Parkinson

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, J. [Klinik fuer Neurologie, Univ. Leipzig (Germany)

    2002-09-01

    Positron-emission-tomography (PET) has enabled to study the metabolism and blood flow in specific brain areas. Besides, there is a variety of radiotracers that allow quantification of the function of distinct molecules. In respect to Parkinson's disease, PET allowed for the first time to assess the number of dopaminergic neurons in vivo. Thus, helping confirming a dopaminergic deficit, measuring disease progression and also help to determine the function of dopaminergic grafts. Current research has shifted to determine the role of related neurotransmitter systems in the pathophysiology of Parkinson's disease. (orig.) [German] Die positronen-emissions-tomographie (PET) bietet neben der Messung von Metabolismus und Blutfluss die Moeglichkeit der Darstellung von einzelnen Molekuelen. Bei Patienten mit Morbus Parkinson hat es diese Technik erstmals erlaubt, die Anzahl der dopaminergen Neurone zu quantifizieren, wodurch die Diagnose gesichert, die Progression der Erkrankung beurteilt und auch das Anwachsen von Implantaten beurteilt werden kann. Die PET hat einen wesentlichen Beitrag zu unserem heutigen Wissen ueber die Pathophysiologie dieser Erkrankung beigetragen. (orig.)

  4. Comparison of CT and MR in 400 patients with suspected disease of the brain and cervical spinal cord

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, W.G. Jr.; Waluch, V.; Yadley, R.A.; Wycoff, R.R.

    1984-09-01

    Magnetic resonance imaging (MR) (0.35T) and computed tomography (CT) were compared in 400 consecutive patients with suspected disease of the brain and cervical spinal cord. Of 325 positive diagnoses, MR detected abnormality while CT was normal in 93; MR was more specific in 68; MR and CT gave equivalent information in 129; CT was more specific in 32; and CT was positive while MR was normal in 3. MR was superior to CT in detection of multiple sclerosis, subcortical arteriosclerotic encephalopathy, posterior fossa infarcts and tumors, small extra-axial fluid collections, and cervical syringomyelia. CT was preferable in evaluation of meningiomas and separation of tumor from edema. CT takes less time and may be preferable in patients with acute trauma as well as very young or elderly individuals. Thus the two studies should be considered complementary.

  5. Comparison of CT and MR in 400 patients with suspected disease of the brain and cervical spinal cord

    International Nuclear Information System (INIS)

    Bradley, W.G. Jr.; Waluch, V.; Yadley, R.A.; Wycoff, R.R.

    1984-01-01

    Magnetic resonance imaging (MR) (0.35T) and computed tomography (CT) were compared in 400 consecutive patients with suspected disease of the brain and cervical spinal cord. Of 325 positive diagnoses, MR detected abnormality while CT was normal in 93; MR was more specific in 68; MR and CT gave equivalent information in 129; CT was more specific in 32; and CT was positive while MR was normal in 3. MR was superior to CT in detection of multiple sclerosis, subcortical arteriosclerotic encephalopathy, posterior fossa infarcts and tumors, small extra-axial fluid collections, and cervical syringomyelia. CT was preferable in evaluation of meningiomas and separation of tumor from edema. CT takes less time and may be preferable in patients with acute trauma as well as very young or elderly individuals. Thus the two studies should be considered complementary

  6. Magnetic resonance imaging-guided attenuation correction of positron emission tomography data in PET/MRI

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2018-01-01

    Synopsis Attenuation correction (AC) is one of the most important challenges in the recently introduced combined positron emission tomography/magnetic resonance imaging (PET/MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients (LACs) of the tissues and other components located in the PET field of view (FoV). MR-AC methods can be divided into three main categories: segmentation-, atlas- and PET-based. This review aims to provide a comprehensive list of the state of the art MR-AC approaches as well as their pros and cons. The main sources of artifacts such as body-truncation, metallic implants and hardware correction will be presented. Finally, this review will discuss the current status of MR-AC approaches for clinical applications. PMID:26952727

  7. Der Briefwechsel zwischen Alexander von Humboldt und Karl Ernst von Baer

    Directory of Open Access Journals (Sweden)

    Thomas Schmuck

    2012-10-01

    Full Text Available Zusammenfassung Der kurze, nicht vollständig erhaltene Briefwechsel zwischen Alexander von Humboldt und Karl Ernst von Baer behandelt sehr verschiedene Themen: Politik, Kriegsgefahr, den Wissenschaftsbetrieb, Auszeichnungen und Tagungen, Embryologie und Cholera. Gemeinsam mit Briefen und Reden ergibt sich dabei ein differenziertes Bild der Beurteilung der beiden Wissenschaftler durch den jeweils anderen. Während Baer sich als Bewunderer Humboldts erweist, erscheint umgekehrt Humboldts Einschätzung Baers als ambivalent. Abstract The short, not completely preserved correspondence between Alexander von Humboldt and Karl Ernst von Baer deals with a wide range of subjects: politics and the danger of war, academic activities, scientific awards and conferences, aspects of embryology and the cholera. Letters to third persons and speeches, together with the correspondence between Humboldt and Baer show a differentiated pattern of mutual appraisal: While Baer always remained an admirer of the elder naturalist, Humboldt’s estimation was characterized by ambivalence.

  8. Digital subtraction in gadolinium-enhanced MR imaging of the brain: a method to reduce contrast dosage

    International Nuclear Information System (INIS)

    Chan, J.H.M.; Tsui, E.Y.K.; Chan, C.Y.; Lai, K.F.; Cheung, Y.K.; Wong, K.P.C.; Yuen, M.K.; Chau, L.F.; Fong, D.; Mok, C.K.

    2002-01-01

    The aim of the study was to investigate the feasibility of using digital subtraction in contrast-enhanced MR imaging of the brain to reduce the MR contrast dosage without jeopardizing patient care. Fifty-two patients with intracranial lesions, either intra-axial or extra-axial, detected by computerized tomography were selected for contrast-enhanced MR imaging with half-dose and full-dose of gadopentetate dimeglumine. The half-dose unsubtracted, full-dose unsubtracted, and half-dose subtracted MR images were visually assessed by counting the number of enhancing brain lesions in the images and quantitatively analyzed by computing their lesion contrast-to-background ratios (CBR). The visual conspicuity of the half-dose subtracted MR images was comparable to that of the full-dose unsubtracted MR images (p>0.05), whereas the CBR of the half-dose subtracted images was approximately two to three times higher than that of the full-dose unsubtracted images. The half-dose subtracted T1-weighted spin-echo images might be able to replace the conventional standard-dose T1-weighted spin-echo images in MR imaging of the brain. (orig.)

  9. Diagnostic criteria in MR neurography; Diagnostische Kriterien in der MR-Neurographie

    Energy Technology Data Exchange (ETDEWEB)

    Baeumer, P. [Deutsches Krebsforschungszentrum, Allgemeinradiologie, Heidelberg (Germany); Universitaetsklinikum Heidelberg, Abteilung fuer Neuroradiologie, Heidelberg (Germany)

    2017-03-15

    Peripheral neuropathies are frequent and can mostly be correctly diagnosed by clinical examination and electrophysiology; however, diagnostically difficult cases are sometimes encountered especially with respect to precise localization of nerve lesions. Imaging of the peripheral nervous system has been shown to provide additional useful diagnostic information. In addition to the more widely available nerve sonography, magnetic resonance neurography (MRN) is the method of choice in diagnostically complex cases. The most important pulse sequence is a T2-weighted fat-saturated pulse sequence with high in-plane resolution and detects increased T2-weighted signals of nerve fascicles as a highly sensitive sign for nerve lesions. Further established diagnostic criteria are nerve caliber and, less commonly used, contrast agent uptake. The spatial pattern of nerve lesions aids in the diagnostic classification of neuropathies. Functional imaging techniques, such as diffusion tensor imaging (DTI) and nerve perfusion are currently under examination with respect to the clinical potential. If all other diagnostic methods, including clinical examination, electrophysiology and nerve sonography do not arrive at an unambiguous diagnosis of a peripheral neuropathy, MRN should be used. The special value of MRN is demonstrated particularly in complex nerve lesions, such as traumatic plexopathies and in partial fascicular neuropathies and many other indications. (orig.) [German] Periphere Neuropathien sind haeufig und meist gut mithilfe klinischer Untersuchung und Elektrophysiologie zu diagnostizieren. Immer wieder gibt es jedoch diagnostisch schwierige Faelle, insbesondere auch hinsichtlich der praezisen Lokalisation von Nervenlaesionen. Die Etablierung bildgebender Verfahren auch fuer das periphere Nervensystem hat sich als hilfreiche zusaetzliche Diagnostik erwiesen. Neben der breiter verfuegbaren Nervensonographie ist die MR-Neurographie (MRN) Methode der Wahl bei der Diagnostik

  10. Gd-DTPA-enhanced T{sub 1}-weighted excretory MR urography after low-dose diuretic injection; T{sub 1}-gewichtete MR-Ausscheidungsurographie mittels Gd-DTPA und vorheriger niedrigdosierter Gabe eines Diuretikums

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Buecker, A.; Adam, G.; Neuerburg, J.; Guenther, R.W. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1997-09-01

    Purpose: Assessment of the morphology of the urinary tract by gadolinium(Gd)-enhanced T{sub 1}-weighted MR-urography (MRU) and precontrast diuretic injection. Methods: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T{sub 1}-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. Results: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. (orig./AJ) [Deutsch] Ziel: Darstellung der Morphologie der ableitenden Harnwege mittels T{sub 1}-gewichteter MR-Urographie (MRU) nach Gabe eines nierengaengigen Gadolinium(Gd)-Chelates und vorheriger Diuretikumapplikation. Methoden: Der Harntrakt von 5 Patienten wurde nach Injektion von Gd-DTPA mit koronaren T{sub 1}-gewichteten 3D-Gradienten-Echo-Sequenzen unterschiedlicher Ortsaufloesung untersucht. Vor der Kontrastmittelgabe wurden jeweils 10 mg Furosemid intravenoes verabreicht. Ergebnisse: Nach initialer Steigerung des Harnflusses durch Furosemidgabe wurden Uebersichtsurogramme mit vollstaendig durchzeichnenden Ureteren bereits 10 min nach Gd-Injektion erzielt. Maximumintensitaetsprojektionen ermoeglichten die Beurteilung des dreidimensionalen Verlaufes der Ureteren ohne Blasenueberlagerung. Eine genauere anatomische Darstellung der Nierenkelche erforderte neben einem guten Fuellungszustand eine moeglichst hohe Sequenzaufloesung, die mit Uebersichtsurogrammen allein nicht zu erreichen war. (orig./AJ)

  11. Evaluation von Bildungssoftware im Spannungsfeld von Objektivität und praktischer Anwendung

    Directory of Open Access Journals (Sweden)

    Cornelia Biffi

    2002-05-01

    Full Text Available Das Angebot an Bildungs- bzw. Lernsoftware umfasst eine breite Palette von sehr unterschiedlichen Produkten. Eigentliche Unterrichtssoftware, die speziell für den Unterricht hergestellt und auf Lehrmittel und Curriculum abgestimmt ist, gibt es kaum. Im Projekt «Lernsoftware Evaluation» des Pestalozzianums Zürich ermitteln Lehrpersonen die Qualität von Bildungssoftware, indem sie diese im Unterricht einsetzen und anhand eines Kriterienrasters beurteilen. Eine Analyse der in der Evaluation generierten Daten belegt die Problematik des Anspruchs einer objektiven Qualitätsbeurteilung. Es werden die Probleme bei der Anwendung von Kriterienraster und Beurteilungsmodus aufgezeigt und ermittelt, worin die subjektiven Qualitätsmassstäbe der Evaluierenden begründet sind. Diese Ausführungen sind Teil eines Forschungsprojekts für die Weiterentwicklung einer theoretisch fundierten, aber dennoch praxisnahen Evaluation von Bildungssoftware.

  12. Bull's-eye map of myocardial perfusion MR imaging. Comparison with SPECT

    International Nuclear Information System (INIS)

    Nomura, Yukihiro; Nanjo, Shuji; Yamazaki, Junichi; Yoshikawa, Kohki; Inoue, Yusuke

    2003-01-01

    When diagnosing heart disease, chest roentgenograms, ultrasonography, single-photon emission computed tomography (SPECT), and coronary arteriography are usually performed. Magnetic resonance (MR) imaging is not widely used for evaluating heart disease. Recent technological progress has allowed high quality images of the heart to be reliably obtained. A routine MR study taking about 30-40 minutes can provide a large amount of diagnostic information, such as cardiac structure, function, perfusion, and myocardial viability. The analysis software that can offer Bull's-eye maps from myocardial perfusion images has recently become commercially available. In this study, the characteristics of Bull's-eye mapping of MR imaging is compared with that of Bull's-eye mapping of SPECT using the same heart phantom. The difference in the image quality of the Bull's-eye maps was evaluated among the receiver coils of MR imaging. On Bull's-eye maps from both MR imaging and SPECT, decreased signal intensity was noted in the posterolateral wall. The degree of decrease in the signal of the MR imaging was more prominent than of SPECT. The decrease was severe for the general-purpose receive-only flexible (GPFLEX) coil, moderate for the cardiac and TORSO coil, and slight for the body coil. In the selection of a coil, it is necessary to take into consideration the trade-off between the distribution of signal intensity and the signal-to-noise ratio (SNR). (author)

  13. Evaluation of two methods for using MR information in PET reconstruction

    International Nuclear Information System (INIS)

    Caldeira, L.; Scheins, J.; Almeida, P.; Herzog, H.

    2013-01-01

    Using magnetic resonance (MR) information in maximum a posteriori (MAP) algorithms for positron emission tomography (PET) image reconstruction has been investigated in the last years. Recently, three methods to introduce this information have been evaluated and the Bowsher prior was considered the best. Its main advantage is that it does not require image segmentation. Another method that has been widely used for incorporating MR information is using boundaries obtained by segmentation. This method has also shown improvements in image quality. In this paper, two methods for incorporating MR information in PET reconstruction are compared. After a Bayes parameter optimization, the reconstructed images were compared using the mean squared error (MSE) and the coefficient of variation (CV). MSE values are 3% lower in Bowsher than using boundaries. CV values are 10% lower in Bowsher than using boundaries. Both methods performed better than using no prior, that is, maximum likelihood expectation maximization (MLEM) or MAP without anatomic information in terms of MSE and CV. Concluding, incorporating MR information using the Bowsher prior gives better results in terms of MSE and CV than boundaries. MAP algorithms showed again to be effective in noise reduction and convergence, specially when MR information is incorporated. The robustness of the priors in respect to noise and inhomogeneities in the MR image has however still to be performed

  14. Prospective early detection of avascular necrosis of the femoral head with MR imaging in high-risk patients: Is it clinically relevant

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Binswanger, U.

    1987-01-01

    To evaluate the clinical relevance of early detection of avascular necrosis (AVN) of the femoral head in a high-risk group, the authors performed MR imaging in 16 renal transplant patients receiving prednisone. Imaging was done at 3-month intervals over 8-24 months. Of the 15 patients remaining in the study (one underwent nephrectomy), two have shown clear MR imaging signs of early AVN persisting for 12 months without clinical symptoms. One patient had an abrupt onset of clinically relevant AVN before the second control MR imaging study was done. These results suggest that MR imaging may detect clinically irrelevant AVN, and that even short intervals between examinations may be too long to provide a warning of impending AVN

  15. Therapeutic impact of [18F]fluoride positron-emission tomography/computed tomography on patients with unclear foot pain

    International Nuclear Information System (INIS)

    Fischer, Dorothee Rita; Hesselmann, Rolf; Johayem, Anass; Hany, Thomas F.; Schulthess, Gustav K. von; Strobel, Klaus; Maquieira, Gerardo J.; Espinosa, Norman; Zanetti, Marco

    2010-01-01

    To evaluate the therapeutic impact of [ 18 F]fluoride positron-emission tomography/computed tomography ([ 18 F]fluoride PET/CT) imaging on patients with unclear foot pain. Twenty-eight patients were prospectively included in this study. Therapeutic management was defined by two experienced dedicated foot surgeons before and after [ 18 F]fluoride PET/CT imaging. Twenty-six patients underwent cross-sectional imaging [CT, magnetic resonance (MR)] prior to PET/CT. A retrospective analysis of the magnetic resonance imaging (MRI) diagnoses was performed when a therapy change occurred after PET/CT imaging. In 13/28 (46%) patients therapeutic management was changed due to PET/CT results. Management changes occurred in patients with the following diagnoses: os trigonum syndrome; sinus tarsi syndrome; os tibiale externum syndrome; osteoarthritis of several joints; non-consolidated fragments; calcaneo-navicular coalition; plantar fasciitis; insertional tendinopathy; suggestion of periostitis; neoarticulations between metatarsal bones. Os trigonum, os tibiale externum, subtalar osteoarthritis and plantar fasciitis were only seen to be active on PET/CT images but not on MR images. [ 18 F]fluoride PET/CT has a substantial therapeutic impact on management in patients with unclear foot pain. (orig.)

  16. Spontaneous osteonecrosis of the knee joint: MR imaging before and after administration of gadopentetate-dimeglumine, comparison to CT, scintigraphy, and histology; Spontane Osteonekrose des Kniegelenkes: MRT im Vergleich zur CT, Szintigraphie und Histologie

    Energy Technology Data Exchange (ETDEWEB)

    Lang, P. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States); Grampp, S. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States); Vahlensieck, M. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)]|[Radiologische Klinik, Bonn Univ. (Germany); Mauz, M. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)]|[Radiologische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Steiner, E. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria); Schwickert, H. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)]|[Radiologische Klinik, Universitaetsklinik Mainz (Germany); Gindele, A. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States); Felix, R. [Radiologische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Genant, H.K. [Dept. of Radiology, Univ. of California, San Francisco, CA (United States)

    1995-06-01

    Eight patients with spontaneous osteonecrosis of the knee joint underwent MR imaging before and after i.v. administration of Gd-DTPA. Nuclear scintigraphy was performed in all 8 patients, three patients also had CT scans of the knee area. Histologic correlation was available in three patients. Increased radionuclide uptake was observed in all patients. In one patient, however, scintigraphy showed increased radionuclide uptake consistent with ostenecrosis only in the medial femoral condyle, while MR imaging demonstrated osteonecrosis both in the medial as well as the lateral femoral condyles. MR demonstrated areas of low signal intensity on precontrast T{sub 1}-weighted images in the femoral condyle in all patients. All these areas showed high signal intensity on T{sub 2}-weighted images. On postcontrast T{sub 1}-weighted images, signal intensity increase was either homogeneous throughout the lesion or it was seen at the periphery of the lesion in a band-like pattern. Histologically, the areas of high signal intensity on T{sub 2}-weighted and on postcontrast T{sub 1}-weighted images corresponded to granulation tissue. (orig./MG) [Deutsch] Wir untersuchten acht Patienten mit einer spontanen Osteonekrose des Kniegelenkes mit der MRT. Ein Vergleich zum szintigraphischen Befund wurde bei allen 8 Patienten und zur CT bei drei Patienten angestellt. Eine histologische Korrelation war bei drei Patienten moeglich. Bei allen 8 Patienten zeigten die T{sub 1}-gewichteten MR-Tomographien Zonen mit reduzierter Signalintensitaet in den Kondylen, waehrend die Laesionen in den T{sub 2}-gewichteten Aufnahmen eine hoehere Signalintensitaet als das normale Knochenmark hatten. Nach Gabe von Gd-DTPA war entweder eine homogene Signalerhoehung oder eine bandfoermige Signalintensitaetszunahme in der Peripherie der Laesion zu sehen. Die Zonen mit hoher Signalintensitaet in der T{sub 2}-gewichteten Aufnahme oder mit Kontrastmittelanreicherung entsprachen histologisch Granulationsgewebe an der

  17. A case report on a severe anaphylaxis reaction to Gadolinium-based MR contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil; Kim, Tae Hyung; Park, Chang Min; Yoon, Soon Ho; Lee, Whal; Kang, Hye Ryun; Choi, Young Hun [Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-02-15

    Acute hypersensitivity reactions to gadolinium-based magnetic resonance (MR) contrast media have been shown to have a much lower incidence and they are generally milder in terms of severity than acute adverse reactions associated with the use of iodinated contrast media for computed tomography scans. However, even though it is rare, a severe hypersensitivity reaction to MR contrast media can occur. Here we present the case of a 66-year-old woman who experienced a severe hypersensitivity reaction after administration of gadolinium-based contrast media without a previous history of allergies.

  18. Development and application of dynamic MR-imaging for evaluation of perfusion changes in rectal carcinoma during a course of radiotherapy in clinical use. Preliminary results; Entwicklung und Anwendung dynamischer MRT-Messungen zur Evaluierung von Perfusionsveraenderungen bei Rektumkarzinomen unter Bestrahlung in der klinischen Routine. Erste Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Vries, A. de; Griebel, J.; Gneiting, T.; Hoflehner, J.; Brandl, M.; Lukas, P. [Leopold-Franzens-Univ. Innsbruck (Austria). Universitaetsklinik fuer Strahlentherapie - Radioonkologie; Judmaier, W.; Kremser, C.; Schocke, M.; Aichner, F. [Leopold-Franzens-Univ. Innsbruck (Austria). Inst. fuer Magnetresonanztomographie; Peer, S.; Rettl, G. [Leopold-Franzens-Univ. Innsbruck (Austria). Universitaetsklinik fuer Radiodiagnostik I; Oefner, D. [Leopold-Franzens-Univ. Innsbruck (Austria). Universitaetsklinik fuer Chirurgie; Debbage, P. [Leopold-Franzens-Univ. Innsbruck (Austria). Inst. fuer Histologie und Embryologie

    1999-11-01

    Purpose: This study was aimed at measuring microcirculatory parameters and contrast medium accumulation within the rectal carcinoma during fractionated radiotherapy in the clinical setting. Material and methods: Perfusion data were observed in patients with rectal carcinoma (n=8) who underwent a preoperative combined chemo-radiotherapy. To acquire perfusion data, an ultrafast T1 mapping sequence was carried out on a 1.5-Tesla whole body imager to obtain T1 maps at intervals of 14 or 120 seconds. The overall measurement time was 40 minutes. The transaxial slice thickness (5 mm) was chosen in such a way that both arterial vessels and the tumor could be clearly identified. The gadolinium-DTPA (Gd-DTPA) concentration time curve was evaluated for arterial blood and tumor after intravenous constant rate infusion. The method allows a spatial resolution of 2x2x5 mm and a temporal resolution of 14 seconds. Patients underwent MR imaging before and at constant intervals during fractionated radiotherapy. Results: Spatial and temporal resolution of dynamic T1 mapping was sufficient to reveal varying CM accumulation levels within the tumor and to identify the great arteries in the pelvis. In 6 patients Gd-DTPA concentration-time-curves were evaluated within the tumor during radiation. Pi index of Gd-DTPA versus radiation dose showed a significant increase in the first or second week of treatment, then either returned slowly to retreatment level or a renewed increase was observed. The average Pi-value at the beginning was 0.16 ({+-}0.049), reaching highest level of 0.23 ({+-}0.058). In all groups the rise from the Pi-value to the Pi-maximum was statistically significant. The relative increase in perfusion ranged between 20 to 83%. Conclusion: The results show, that the ultrafast MR-technique described above provide a suitable tool for monitoring tumor microcirculation during therapeutic interventions and offers the potential for an individualized optimization of therapeutic

  19. [Friedrich Ludwig von Maydelli pildid Baltimaade ajaloost = Friedrich Ludwig von Maydells Baltische Geschichte in Bildern = Friedrich Ludwig von Maydell ́s Baltic history in images] / Ulrike Plath

    Index Scriptorium Estoniae

    Plath, Ulrike, 1972-

    2014-01-01

    Arvustus: Friedrich Ludwig von Maydelli pildid Baltimaade ajaloost = Friedrich Ludwig von Maydells Baltische Geschichte in Bildern = Friedrich Ludwig von Maydell ́s Baltic history in images. Eesti kunstimuuseum, Kadrioru kunstimuuseum. Tallinn 2013

  20. Mr. Robot: Schizophrenie, Paranoia und korporative Gier

    Directory of Open Access Journals (Sweden)

    jan jagodzinski

    2016-11-01

    Full Text Available Der vorliegende Beitrag untersucht die erste Staffel von Mr. Robot (2015 − aus Gilles Deleuzes symptomatologischer Position, die sich auf das Spannungsfeld zwischen ‹dem Klinischen und dem Kritischen› fokussiert. Zum Zeitpunkt des Verfassens dieses Artikels war nur die erste Staffel verfügbar. Im Folgenden zeige ich am Beispiel der Hauptfigur Elliot Anderson, inwiefern die Serie Einblicke in unsere ‹Kontrollgesellschaft› – auch eine Deleuzsche Entwicklung – gewähren kann. Zudem wird ein Vergleich mit dem Film «Kein System ist sicher», der ähnliche gesellschaftliche Fragen thematisiert, vorgenommen. Obwohl ich auf medienpädagogische Aspekte nur indirekt eingehen werde, hebe ich im Laufe der Argumentation hervor, dass solche Fernsehnarrative das allgemeine Publikum oder das, was ich als ‹jedermann› beschreibe, mit ethischen Problemen und Dilemmata unserer globalen kapitalistischen Ordnung konfrontieren.

  1. Characterization of adrenal masses: can image replace biopsy?; Charakterisierung von Nebennierenraumforderungen. Kann die Bildgebung die Biopsie ersetzen?

    Energy Technology Data Exchange (ETDEWEB)

    Heinz-Peer, G.; Hoenigschnabel, S.; Lechner, G. [Universtaetsklinik fuer Radiodiagnostik, Abt. Chirurgische Faecher, Wien (Austria)]|[Ludwig Boltzmann-Inst. fuer Radiologische Tumorforschung, Wien (Austria); Niederle, B. [Universitaetsklinik fuer Chirurgie, Univ. Wien (Austria)

    1999-07-01

    This paper describes the diagnostic value of new imaging techniques in characterization of adrenal masses and evaluates the role of adrenal biopsy. For differentiation of benign and malignant adrenal lesions, sensitivities and specificities of 85-100% can be reached by unenhanced computed tomography (CT) methods, chemical shift techniques in magnetic resonance imaging (MRI), delayed enhanced CT techniques, and by evaluation of wash-out curves in contrast-enhanced CT. The diagnostic value of all CT techniques depends on threshold values. The value of dynamic contrast-enhanced MRI is under discussion and should be reevaluated by using delayed enhance series. Biochemical and scintigraphic methods (NP 59 iodine iodomethyl-norcholesterol and MIBG meta-iodobenzylguanidine scintigrams) are valuable for the diagnosis of functional adrenal masses; however, they do not allow differentiation of benign and malignant tumors. According to excellent results of new imaging techniques in characterization of adrenal masses, the indications for fine-needle aspiration biopsy have already regressed, as have complications associated with this invasive technique. (orig.) [Deutsch] Diese Arbeit beschreibt die Moeglichkeiten der Charakterisierung von Nebennierenlaesionen durch die Bildgebung von neuen Untersuchungstechniken und evaluiert den geaenderten Stellenwert der Nebennierenbiopsie. Mittels der nativen Computertomographie (CT), der Chemical-Shift-Technik der Magnetresonanztomographie (MRT) oder Dichtemessungen in CT-Kontrastmittelspaetserien bzw. der Bestimmung des prozentuellen Dichteverlustes in CT-Kontrastmittelserien koennen in der Differenzierung von benignen und malignen Nebennierenlaesionen Sensitivitaeten und Spezifitaeten von 85%-100% erreicht werden. Die diagnostische Wertigkeit der CT-Techniken ist abhaengig von der Definition eines Schwellenwertes. Die Wertigkeit der dynamischen KM-verstaerkten MRT wird derzeit unterschiedlich beurteilt und sollte anhand verbesserter

  2. Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR

    Energy Technology Data Exchange (ETDEWEB)

    Maffei, Erica; Seitun, Sara [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Messalli, Giancarlo; Catalano, Onofrio [SDN Foundation - IRCCS, Naples (Italy); Martini, Chiara; Cademartiri, Filippo [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Nieman, Koen; Rossi, Alexia; Mollet, Nico R. [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Guaricci, Andrea I. [Azienda Ospedaliero-Universitaria di Foggia, Department of Cardiology, Foggia (Italy); Tedeschi, Carlo [Ospedale San Gennaro, Department of Cardiology, Naples (Italy)

    2012-05-15

    To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced-steady state free precession) SAX sequence for MR, and evaluated using dedicated software. CT and MR images showed good agreement: LV EF (Ejection Fraction) (52 {+-} 14% for CT vs. 52 {+-} 14% for MR; r = 0.73; p > 0.05); RV EF (47 {+-} 12% for CT vs. 47 {+-} 12% for MR; r = 0.74; p > 0.05); LV EDV (End Diastolic Volume) (74 {+-} 21 ml/m{sup 2} for CT vs. 76 {+-} 25 ml/m{sup 2} for MR; r = 0.59; p > 0.05); RV EDV (84 {+-} 25 ml/m{sup 2} for CT vs. 80 {+-} 23 ml/m{sup 2} for MR; r = 0.58; p > 0.05); LV ESV (End Systolic Volume)(37 {+-} 19 ml/m{sup 2} for CT vs. 38 {+-} 23 ml/m{sup 2} for MR; r = 0.76; p > 0.05); RV ESV (46 {+-} 21 ml/m{sup 2} for CT vs. 43 {+-} 18 ml/m{sup 2} for MR; r = 0.70; p > 0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. Cardiac CT provides accurate and reproducible LV and RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. circle Cardiac-CT is able to provide Left and Right Ventricular function. circle Cardiac-CT is accurate as MR for LV and RV volume assessment. (orig.)

  3. Allogeneic cell transplant expands bone marrow distribution by colonizing previously abandoned areas: an FDG PET/CT analysis.

    Science.gov (United States)

    Fiz, Francesco; Marini, Cecilia; Campi, Cristina; Massone, Anna Maria; Podestà, Marina; Bottoni, Gianluca; Piva, Roberta; Bongioanni, Francesca; Bacigalupo, Andrea; Piana, Michele; Sambuceti, Gianmario; Frassoni, Francesco

    2015-06-25

    Mechanisms of hematopoietic reconstitution after bone marrow (BM) transplantation remain largely unknown. We applied a computational quantification software application to hybrid 18F-fluorodeoxyglucose positron emission tomography (PET)/computed tomography (CT) images to assess activity and distribution of the hematopoietic system throughout the whole skeleton of recently transplanted patients. Thirty-four patients underwent PET/CT 30 days after either adult stem cell transplantation (allogeneic cell transplantation [ACT]; n = 18) or cord blood transplantation (CBT; n = 16). Our software automatically recognized compact bone volume and trabecular bone volume (IBV) in CT slices. Within IBV, coregistered PET data were extracted to identify the active BM (ABM) from the inactive tissue. Patients were compared with 34 matched controls chosen among a published normalcy database. Whole body ABM increased in ACT and CBT when compared with controls (12.4 ± 3 and 12.8 ± 6.8 vs 8.1 ± 2.6 mL/kg of ideal body weight [IBW], P bones, ABM increased three- and sixfold in CBT and ACT, respectively, compared with controls (0.9 ± 0.9 and 1.7 ± 2.5 vs 0.3 ± 0.3 mL/kg IBW, P transplanted BM into previously abandoned BM sites. © 2015 by The American Society of Hematology.

  4. Magnetic resonance tomography of renal allografts - Diagnostic possibilities

    International Nuclear Information System (INIS)

    Dewey, C.; Luening, M.

    1988-01-01

    It is the aim of the use of magnetic resonance tomography (MRT) to reduce the existing insufficiency in imaging diagnostics of complications after kidney transplantation. The topical status of examination technique is presented and the criteria of normal and pathological MRT findings are described in detail. (author)

  5. Automatisierung von HiL Tests

    OpenAIRE

    Asbach, Lennart; Ebrecht, Lars

    2010-01-01

    Automatisierung von HiL Tests. Darstellung und Bewertung einer praktischen Umsetzung. Das Poster zeigt die Motivation, die Durchführung, einen aktuellen Stand und einen Ausblick der Testautomatisierung im Bahnlabor RailSiTe. Als Beispiel dient der Konformitätstest von ETCS-Onboard Zugrechnern, um die Einführung von ETCS zu unterstützen.

  6. Die Wirkung von Desacetylcefotaxin, einem Metaboliten von Cefotaxim, in vitro und auf die experimentelle Infektion mit Escherichia coli

    OpenAIRE

    Wirbelauer, J.; Hof, H.; Hacker, Jörg

    2009-01-01

    Die MHK-Werte von Desacetylcefotaxim gegen verschiedene, z. T. ampicillinresistente Stämme von Escherichia coH, die mit Hilfe einer Agardilutionsmethode erhoben wurden, waren höher als die von Cefotaxim und Ceftriaxon, jedoch niedriger als die von Cefoxitin. In einem Modell der systemischen Infektion der Maus mit einem plasmidtragenden, betalactamaseproduzierenden Stamm von E. coli führte die Therapie mit Desacetylcefotaxim zu einer starken Reduktion der Keime pro Leber. Im Vergleich zur Ther...

  7. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  8. {sup 1}H-MR spectroscopy in anorexia nervosa. Reversible cerebral metabolic changes; {sup 1}H-MR-Spektroskopie bei Anorexia nervosa: Reversible zerebrale Metabolitenaenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Moeckel, R.; Schlemmer, H.P.; Becker, G.; Koepke, J.; Georgi, M. [Heidelberg Univ. (Germany). Inst. fuer Klinische Radiologie; Gueckel, C.; Goepel, C.; Schmidt, M. [Zentralinstitut fuer Seelische Gesundheit, Mannheim (Germany). Klinik fuer Kinder- und Jugendpsychiatrie; Hentschel, F. [Zentralinstitut fuer Seelische Gesundheit, Mannheim (Germany). Neuroradiologie

    1999-04-01

    Purpose: By using localized {sup 1}H-MR spectroscopy in the brain of patients with anorexia nervosa we wanted to verify our preliminary results and to look for a reversibility of the metabolic changes under therapy. Methods: In 22 patients and 17 healthy volunteers (11 follow-up examinations) single voxel {sup 1}H-MR spectroscopy (TE=50 ms, TM=30 ms, TR=1500 ms, voxel (2 cm){sup 3}, acq.: 256) was used in two different localizations (thalamus and parieto-occipital region). The first examination of the patients was performed before therapy, the follow-up examination at the end of therapy. Results: In both regions of the brain we found a statistically significant elevation of the Cho/Cr-ratio in comparison to normal controls. The follow-up examinations revealed reversibility of the metabolic changes under successful therapy. Conclusion: {sup 1}H-MR spectroscopy reveals metabolic changes in the brain of patients with anorexia nervosa, which are reversible under successful therapy. These metabolic changes can be conclusively explained using a biochemical model. (orig.) [Deutsch] Ziel: Im Rahmen dieser weiterfuehrenden Studie sollten die bisherigen Ergebnisse der lokalisierten {sup 1}H-MR-Spektroskopie des Gehirns an Patienten mit Anorexia nervosa verifiziert werden. Weiter sollte ueberprueft werden, ob die von uns nachgewiesenen metabolischen Veraenderungen unter Therapie reversibel sind. Methode: Die {sup 1}H-MR-Spektren wurden bei 22 Patientinnen und 17 Probanden (11 Verlaufskontrollen) in Einzelvolumentechnik (TE=50 ms, TM=30 ms, TR=1500 ms, Voxel: (2 cm){sup 3}, Acq.: 256) in zwei unterschiedlichen Hirnregionen (Thalamus, parieto-okzipitale Region) durchgefuehrt. Die erste Untersuchung der Patienten erfolgte bei Aufnahme und die Verlaufskontrolle zum Abschluss der stationaeren Behandlung. Ergebnisse: Bei den Patienten wurde in beiden Hirnregionen ein statistisch signifikant erhoehter Wert fuer das Cho/Cr-Verhaeltnis im Vergleich zu dem Normalkollektiv nachgewiesen

  9. (18)F-Fluorodeoxyglucose PET/Computed Tomography for Primary Brain Tumors

    DEFF Research Database (Denmark)

    Antonsen Segtnan, Eivind; Hess, Søren; Grupe, Peter

    2015-01-01

    Structural imaging with computed tomography (CT) and MR imaging is the mainstay in primary diagnosis of primary brain tumors, but these modalities depend on morphologic appearance and an intact blood-brain barrier, and important aspects of tumor biology are not addressed. Such issues may...

  10. Indications for application of a high resolution coil in MR tomography. Indikationen zur Applikation einer Hochaufloesungsspule in der MR-Tomographie

    Energy Technology Data Exchange (ETDEWEB)

    Maeurer, J. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Requardt, H. (Siemens AG, Erlangen (Germany)); Mueller, F. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Steinkamp, H.J. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Hosten, N. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Langer, R. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany)); Felix, R. (Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany))

    1994-04-01

    This is the first study with high spatial resolution Magnetic Resonance Imaging (MRI), performed with a high resolution coil in a clinical whole-body system. Measurements were recorded with a slice thickness of 2 mm. A 256x256 matrix and a 2.5 cm field of view were used resulting in a pixel size of 1.01 mm[sup 2]. MR images of the skin, hand, wrist, knee and ankle of 14 healthy volunteers, of three anatomic pathology tissue specimens and of three formalin-fixed specimens were obtained. Normal anatomy was identified and compared with the three gross anatomic pathology sections. The skin, hands, wrists and ankles of 30 patients were examined and a variety of pathological lesions were detected, including cutaneous neoplasms and ulceration, acute and chronic tendon lesions and pathologic features of the bone and wrist. Based on the excellent imaging of anatomic detail and superior contrast resolution, high resolution MRI proved an important complement for preoperative diagnosis. (orig.)

  11. Basic methodology of tomographic imaging by filtered inverse projection at a turbo-pump. Project report; Methodische Grundlagen fuer die Tomographie durch gefilterte Rueckprojektion an einer Axialpumpe. Projektbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, D.

    2000-11-01

    A two-phase medium consisting of a fluid containing gas is transported in a turbo-pump via an impeller. The interaction between the gaseous phase and the impeller is to be examined by tomography with gamma rays. Reconstruction of the image of the object is to be made by way of filtered inverse projection. The methodology of using this principle in the given system (geometry and measuring conditions) is explained. (orig./CB) [German] Ein zweiphasiges, aus einer gashaltigen Fluessigkeit bestehendes Medium wird in einer Axialpumpe von einem propellerartigen Laufrad senkrecht zur Drehachse dieses Laufrades transportiert. Die Wechselwirkung zwischen der Gasphase und dem Laufrad soll unter Verwendung von Gamma-Strahlung mittels Tomographie untersucht werden. Dabei ist fuer die Rekonstruktion des Objektbildes das Prinzip der sogenannten gefilterten Rueckprojektion vorgesehen. Die methodischen Grundlagen fuer die Nutzung dieses Prinzips unter von vorgesehenen geometrischen und messtechnischen Bedingungen sind Gegenstand dieser Arbeit. (orig.)

  12. Eine Analyse des Zusammenhangs zwischen dem Konsum von Alkopops und dem Problemverhalten von Jugendlichen

    OpenAIRE

    Metzner, Cornelia Beate Isabel

    2007-01-01

    Zielsetzung: In dieser Arbeit wird untersucht, ob bei Jugendlichen ein Zusammenhang zwischen dem Konsum von Alkopops einerseits und dem sonstigen Alkoholtrinkverhalten, dem Konsum von Zigaretten und illegalen Drogen sowie weiteren Risikoverhaltensweisen andererseits besteht, ferner ob sich Unterschiede im Verhalten von Jungen und Mädchen ergeben. Theoretischer und empirischer Hintergrund: �Alkopops�, d. h. Mischgetränke diverser Hersteller aus Likör bzw. Schnaps und Limonade sowie wein- ...

  13. Fluorodeoxyglucose positron emission tomography in pancreatic cancer: an unsolved problem

    International Nuclear Information System (INIS)

    Kato, Takashi; Fukatsu, Hiroshi; Ito, Kengo; Tadokoro, Masanori; Ota, Toyohiro; Ikeda, Mitsuru; Isomura, Takayuki; Ito, Shigeki; Nishino, Masanari; Ishigaki, Takeo

    1995-01-01

    The aim of this study was to examine the significance and problems of 2-[fluorine-18]-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in diagnosing pancreatic cancer and mass-forming pancreatitis (MFP). PET, X-ray computed tomography (CT) and magnetic resonance (MR) imaging were performed in 15 patients with pancreatic cancer and nine patients with MFP. The areas of the PET scan were determined according to the markers drawn on the patients at CT or MR imaging. Regions of interests (ROIs) were placed by reference to the CT or MR images corresponding to the PET images. Tissue metabolism was evaluated by the differential absorption ratio (DAR) at 50 min after intravenous injection of FDG [DAR = tissue tracer concentration/(injected dose/body weight). The DAR value differed significantly in pancreatic cancer (mean±SD, 4.64±1.94) and MFP (mean±SD, 2.84±2.22) (P<0.05). In one false-negative case (mucinous adenocarcinoma), the tumour contained a small number of malignant cells. In one false-positive case, lymphocytes accumulated densely in the mass in the pancreatic head. Further studies are necessary to investigate the histopathological characteristics (especially the cellularity) and other factors affecting the FDG DAR on PET images. (orig.)

  14. Titanisierung von Implantatoberflächen

    Science.gov (United States)

    Zimmermann, Hanngörg; Heinlein, Markus; Guldner, Norbert W.

    Titan gilt seit Jahrzehnten als einer der wichtigsten Implantatwerkstoffe in der Medizin. Neben den guten mechanischen Eigenschaften (Leichtigkeit, hohe Festigkeit etc.), besitzen Titanimplantate vor allem eine hervorragende Körperverträglichkeit, so dass die Implantate optimal in den humanen Organismus integriert werden [1]. Ist jedoch aufgrund der Anforderungen an das Implantat eine hohe Flexibilität und/ oder Elastizität gefragt, so scheidet der Werkstoff Titan aufgrund seiner spröden und unflexiblen Materialeigenschaften aus. Die Folge ist der Einsatz von Implantatmaterialien, sowohl künstlichen als auch biologischen Ursprungs, welche nicht selten eine unzureichende Biokompatibilität aufweisen und somit zu Fremdköper- und immunologischen Reaktionen und Einkapselung des Implantates führen können. Die Erhöhung der Körperverträglichkeit, eine Adaption an das biologische Umfeld und eine hohe Biokompatibilität sind demzufolge die wichtigsten Eigenschaften bei der bedarfsgerechten Herstellung von Implantaten und Implantatoberflächen. Zur Gestaltung von innovativen, biokompatiblen Oberflächen stehen unterschiedliche technische Lösungsansätze zur Verfügung. Zum einen besteht die Möglichkeit, geeignete Oberflächeneigenschaften aus dem Grundmaterial selbst zu optimieren. Dies geschieht unter anderem durch Modifikation der Werkstoffoberflächen in Form von Texturierungen und Oberflächenrauhigkeiten. Zum anderen können die Oberflächeneigenschaften unabhängig von denen des Trägermaterials gestaltet werden. Durch Funktionalisierung der Oberflächen mit geeigneten Beschichtungen oder der Zugabe von Medikamenten (Drug Eluting) werden die Kunststoffimplantate dahingehend verändert, dass eine Steigerung der Körperakzeptanz erreicht wird. Die Titanbeschichtung von Implantatoberflächen kombiniert die positiven Materialeigenschaften von Titan und Polymer.

  15. {sup 11}C-Methionine positron emission tomography may monitor the activity of encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Kenji; Shiga, Tohru; Manabe, Osamu; Tamaki, Nagara [Department of Nuclear Medicine, Graduate School of Medicine, Hokkaido University, Sapporo (Japan)], E-mail: khirata@med.hokudai.ac.jp; Fujima, Noriyuki [Department of Radiology, Graduate School of Medicine, Hokkaido University, Sapporo (Japan); Usui, Reiko [Department of Nuclear Medicine, Graduate School of Medicine, Hokkaido University, Sapporo (Japan); Department of Psychiatry, Graduate School of Medicine, Hokkaido University, Sapporo (Japan); Kuge, Yuji [Central Institute of Isotope Science, Hokkaido University, Sapporo (Japan)

    2012-12-15

    Encephalitis is generally diagnosed by clinical symptoms, cerebrospinal fluid examination, and imaging studies including CT, magnetic resonance imaging (MRI), and perfusion single photon emission tomography (SPECT). However, the role of positron emission tomography (PET) in diagnosis of encephalitis remains unclear. A 49-year-old woman presenting with coma and elevated inflammatory reaction was diagnosed as having encephalitis according to slow activity on electroencephalogram, broad cortical lesion in MR fluid attenuated inversion recovery image, and increased blood flow demonstrated by SPECT. PET revealed increased accumulation of {sup 11}C-methionine (MET) in the affected brain tissues. After the symptom had improved 2 months later, the accumulation of MET as well as the abnormal findings of MR imaging and SPECT was normalized. This case indicated that MET PET may monitor the activity of encephalitis.

  16. MR imaging and positron emission tomography of cortical heterotopia

    Energy Technology Data Exchange (ETDEWEB)

    Bairamian, D.; Di Chiro, G.; Theodore, W.H.; Holmes, M.D.; Dorwart, R.H.; Larson, S.M.

    1985-11-01

    Heterotopia of the gray matter is a developmental malformation in which ectopic cortex is found in the white matter of the brain. A case of a 33-year-old man with cortical heterotopia who had a lifelong history of seizures and psychomotor retardation is reported, including the results of cerebral CT, magnetic resonance imaging, and positron emission tomography using YF-2-deoxyglucose.

  17. MR imaging and positron emission tomography of cortical heterotopia

    International Nuclear Information System (INIS)

    Bairamian, D.; Di Chiro, G.; Theodore, W.H.; Holmes, M.D.; Dorwart, R.H.; Larson, S.M.

    1985-01-01

    Heterotopia of the gray matter is a developmental malformation in which ectopic cortex is found in the white matter of the brain. A case of a 33-year-old man with cortical heterotopia who had a lifelong history of seizures and psychomotor retardation is reported, including the results of cerebral CT, magnetic resonance imaging, and positron emission tomography using 18 F-2-deoxyglucose

  18. Functioning Mediastinal Paraganglioma Associated with a Germline Mutation of von Hippel-Lindau Gene

    Directory of Open Access Journals (Sweden)

    Thibault Bahougne

    2018-05-01

    Full Text Available We report the case of a 21-year old woman presenting with high blood pressure and raised normetanephrine levels. Indium-111-pentetreotide single photon-emission computed tomography with computed tomography (SPECT/CT and 2-deoxy-2-[fluorine-18]fluoro-d-glucose (FDG positron emission tomography/computed tomography (PET/CT imaging showing isolated tracer-uptake by a 2 cm tumor close to the costovertebral angle of the third thoracic vertebra. Thoracic surgery led to normalization of normetanephrine levels. Histological findings were consistent with the presence of a paraganglioma. Mutations in SDHA, SDHB, SDHC, SDHD, RET, SDHAF2, TMEM127, MAX, NF1, FH, MDH2, and EPAS1 were absent, but a heterozygous missense mutation, c.311G > T, was found in exon 1 of the von Hippel-Lindau gene, VHL, resulting in a glycine to valine substitution in the VHL protein at position 104, p.Gly104Val. This same mutation was found in both the mother and the 17-year old sister in whom a small retinal hemangioblastoma was also found. We diagnose an unusual functional mediastinal paraganglioma in this young patient with a germline VHL gene mutation, a mutation previously described as inducing polycythemia and/or pheochromocytoma but not paraganglioma or retinal hemangioblastoma.

  19. Investigation of hindwing folding in ladybird beetles by artificial elytron transplantation and microcomputed tomography.

    Science.gov (United States)

    Saito, Kazuya; Nomura, Shuhei; Yamamoto, Shuhei; Niiyama, Ryuma; Okabe, Yoji

    2017-05-30

    Ladybird beetles are high-mobility insects and explore broad areas by switching between walking and flying. Their excellent wing transformation systems enabling this lifestyle are expected to provide large potential for engineering applications. However, the mechanism behind the folding of their hindwings remains unclear. The reason is that ladybird beetles close the elytra ahead of wing folding, preventing the observation of detailed processes occurring under the elytra. In the present study, artificial transparent elytra were transplanted on living ladybird beetles, thereby enabling us to observe the detailed wing-folding processes. The result revealed that in addition to the abdominal movements mentioned in previous studies, the edge and ventral surface of the elytra, as well as characteristic shaped veins, play important roles in wing folding. The structures of the wing frames enabling this folding process and detailed 3D shape of the hindwing were investigated using microcomputed tomography. The results showed that the tape spring-like elastic frame plays an important role in the wing transformation mechanism. Compared with other beetles, hindwings in ladybird beetles are characterized by two seemingly incompatible properties: ( i ) the wing rigidity with relatively thick veins and ( ii ) the compactness in stored shapes with complex crease patterns. The detailed wing-folding process revealed in this study is expected to facilitate understanding of the naturally optimized system in this excellent deployable structure.

  20. Malignant pleural disease: diagnosis by using diffusion-weighted and dynamic contrast-enhanced MR imaging--initial experience.

    Science.gov (United States)

    Coolen, Johan; De Keyzer, Frederik; Nafteux, Philippe; De Wever, Walter; Dooms, Christophe; Vansteenkiste, Johan; Roebben, Ilse; Verbeken, Eric; De Leyn, Paul; Van Raemdonck, Dirk; Nackaerts, Kristiaan; Dymarkowski, Steven; Verschakelen, Johny

    2012-06-01

    To investigate the use of diffusion-weighted (DW) imaging for differentiating benign lesions from malignant pleural disease (MPD) and to retrospectively assess dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging acquisitions to find out whether combining these measurements with DW imaging could improve the diagnostic value of DW imaging. This study was approved by the local ethics committee, and all patients provided written informed consent. Thirty-one consecutive patients with pleural abnormalities suspicious for MPD underwent whole-body positron emission tomography (PET)/computed tomography (CT) and thorax MR examinations. Diagnostic thoracoscopy with histopathologic analysis of pleural biopsies served as the reference standard. First-line evaluation of each suspicious lesion was performed by using the apparent diffusion coefficient (ADC) calculated from the DW image, and the optimal cutoff value was found by using receiver operating characteristic curve analysis. Afterward, DCE MR imaging data were used to improve the diagnosis in the range of ADCs where DW imaging results were equivocal. Sensitivity, specificity, and accuracy of PET/CT for diagnosis of MPD were 100%, 35.3%, and 64.5%. The optimal ADC threshold to differentiate benign lesions from MPD with DW MR imaging was 1.52 × 10(-3) mm(2)/sec, with sensitivity, specificity, and accuracy of 71.4%, 100%, and 87.1%, respectively. This result could be improved to 92.8%, 94.1%, and 93.5%, respectively, when DCE MR imaging data were included in those cases where ADC was between 1.52 and 2.00 × 10(-3) mm(2)/sec. A total of 20 patients had disease diagnosed correctly, nine had disease diagnosed incorrectly, and two cases were undetermined with PET/CT. DW imaging helped stage disease correctly in 27 patients and incorrectly in four. The undetermined cases at PET/CT were correctly diagnosed at MR imaging. DW imaging is a promising tool for differentiating MPD from benign lesions, with high

  1. Gadolinium-DTPA as an oral contrast medium for MR tomography of the abdomen

    International Nuclear Information System (INIS)

    Krahe, T.; Doelken, W.; Lackner, K.; Houselog, M.

    1990-01-01

    150 MR examinations of the upper abdomen were carried out after the oral administration of 5 ml/kg body weight of a gadolinium DTPA formulation (1.0 mmol/l, 15 g/l manitol), with reference to the delineation of the pancreas, the liver and intra-abdominal fat. For comparison, 100 MR examinations without oral opacification of the G.I. tract were evaluated. Contrast administration resulted in a signal-intensive demonstration of the G.I tract for all measurement sequences. The intraluminal contrast improved the distinction between normal and abnormal structures, T 1 and T 2 sequences and the demonstration of fat on T 2 -weighted series. T 1 -weighted series showed the best diagnostic results. In 25% there was meteorism and diarrhoea within 24 hours of the administration of the oral contrast. (orig.) [de

  2. Formation of multifunctional Fe3O4/Au composite nanoparticles for dual-mode MR/CT imaging applications

    International Nuclear Information System (INIS)

    Hu Yong; Li Jing-Chao; Shen Ming-Wu; Shi Xiang-Yang

    2014-01-01

    Recent advances with iron oxide/gold (Fe 3 O 4 /Au) composite nanoparticles (CNPs) in dual-modality magnetic resonance (MR) and computed tomography (CT) imaging applications are reviewed. The synthesis and assembly of “dumbbelllike” and “core/shell” Fe 3 O 4 /Au CNPs is introduced. Potential applications of some developed Fe 3 O 4 /Au CNPs as contrast agents for dual-mode MR/CT imaging applications are described in detail. (topical review - magnetism, magnetic materials, and interdisciplinary research)

  3. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias [University Hospital of Bern, Inselspital, Department of Radiology, Bern (Switzerland); Steinbach, Lynne S. [University of California San Francisco, Department of Radiology, San Francisco, California (United States); Nagy, Ladislav [University Hospital of Bern, Inselspital, Department of Orthopedic Surgery, Bern (Switzerland)

    2005-06-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  4. MR imaging of avascular scaphoid nonunion before and after vascularized bone grafting

    International Nuclear Information System (INIS)

    Anderson, Suzanne E.; Tschering-Vogel, Dechen; Martin, Matthias; Steinbach, Lynne S.; Nagy, Ladislav

    2005-01-01

    To investigate the magnetic resonance (MR) imaging appearances of chronic nonunion of the scaphoid with proximal pole avascular necrosis before and after insertion of a vascularized bone graft, using computed tomography (CT) as the imaging gold standard. A retrospective study was performed involving MR imaging (n=26), CT scans (n=37) and radiographs (n=52) of 13 men (mean age 29 years, age range 20-38 years) with avascular scaphoid nonunion. Avascular necrosis of the scaphoid proximal pole was confirmed intraoperatively (n=13). MR images were acquired preoperatively and following placement of a vascularized bone graft. Scaphoid MR signal characteristics were assessed for evidence of vascular bone graft incorporation and revascularization of the bone marrow of the proximal pole of the scaphoid and compared with the gold standard of CT. Surgical and clinical notes were reviewed with a minimum 3 year imaging and clinical follow-up in all patients. Graft incorporation with revascularization of the proximal pole of the scaphoid was documented in 9 patients (69%). Graft failure with persistent pseudoarthrosis and avascular necrosis of the scaphoid was seen in 4 patients (31%). MR imaging is useful to determine whether vascularized bone graft incorporation and revascularization of the proximal pole of the scaphoid has occurred in the setting of avascular scaphoid nonunion. (orig.)

  5. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    DEFF Research Database (Denmark)

    Lassen, Martin L; Muzik, Otto; Beyer, Thomas

    2017-01-01

    The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET)-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic paramet...

  6. FDG PET/CT and MR imaging of intramuscular myxoma in the gluteus maximus

    Directory of Open Access Journals (Sweden)

    Nishio Jun

    2012-06-01

    Full Text Available Abstract Intramuscular myxoma is a rare benign soft tissue tumor which may be mistaken for other benign and low-grade malignant myxoid neoplasms. We present the case of a 63-year-old woman with an asymptomatic intramuscular myxoma discovered incidentally on a whole-body F-18 fluorodeoxyglucose (FDG positron emission tomography (PET/computed tomography. PET images showed a mild FDG uptake (maximum standardized uptake value, 1.78 in the left gluteus maximus. Subsequent magnetic resonance (MR imaging revealed a well-defined ovoid mass with homogenous low signal intensity on T1-weighted sequences and markedly high signal intensity on T2-weighted sequences. Contrast-enhanced MR images showed heterogeneous enhancement throughout the mass. The diagnosis of intramuscular myxoma was confirmed on histopathology after surgical excision of the tumor. The patient had no local recurrence at one year follow-up. Our case suggests that intramuscular myxoma should be considered in the differential diagnosis of an oval-shaped intramuscular soft tissue mass with a mild FDG uptake.

  7. Preclinical evaluation of a 68Ga-labeled biotin analogue for applications in islet transplantation

    International Nuclear Information System (INIS)

    Eriksson, Olof; Carlsson, Fredrik; Blom, Elisabeth; Sundin, Anders; Långström, Bengt; Korsgren, Olle; Velikyan, Irina

    2012-01-01

    Introduction: Islet transplantation is a promising treatment for type 1 diabetes mellitus, but the fate of the cells after intraportal infusion is unclear. It is therefore imperative to develop novel techniques for noninvasive imaging and quantification of events following islet transplantation. Methods: Small islet-like microbeads, avidin-covered agarose resins (AARs), were used as a model system for islet transplantation. Capability for specific [ 68 Ga]Ga-DOTA-(PEG) 2 -biotin uptake and retention for either AARs or human islets conjugated with avidin by means of a heparin scaffold was studied in vitro. Biodistribution of the novel positron emission tomography (PET) tracer [ 68 Ga]Ga-DOTA-(PEG) 2 -biotin was evaluated in mice treated by intraportal transplantation of AARs by μPET/computed tomography and ex vivo organ distribution and compared with control mice. Results: AARs had high capability to bind [ 68 Ga]Ga-DOTA-(PEG) 2 -biotin, close to 50% of administrated tracer/μl in vitro (>0.25 MBq/μl). Avidin-tagged human islets could bind on average 2.2% of administered tracer/μl. Specificity (>90%) and retention (>90% after 1 h) were high for both AARs and avidin-tagged islets. Hepatic tracer uptake and retention were increased in mice transplanted with AARs [standardized uptake value (SUV)=2.6] compared to the untreated group (SUV=1.4). In vivo uptake of tracer to AARs was blocked by preadministration of unlabeled biotin. Conclusions: Avidin-tagged islet-like objects can be tracked in hepatic volume after intraportal transplantation by using [ 68 Ga]Ga-DOTA-(PEG) 2 -biotin and PET.

  8. Computed Tomography and Magnetic Resonance Imaging Features of the Temporomandibular Joint in Two Normal Camels

    Directory of Open Access Journals (Sweden)

    Alberto Arencibia

    2012-01-01

    Full Text Available Computed tomography (CT and magnetic resonance (MR image features of the temporomandibular joint (TMJ and associated structures in two mature dromedary camels were obtained with a third-generation equipment CT and a superconducting magnet RM at 1.5 Tesla. Images were acquired in sagittal and transverse planes. Medical imaging processing with imaging software was applied to obtain postprocessing CT and MR images. Relevant anatomic structures were identified and labelled. The resulting images provided excellent anatomic detail of the TMJ and associated structures. Annotated CT and MR images from this study are intended as an anatomical reference useful in the interpretation for clinical CT and MR imaging studies of the TMJ of the dromedary camels.

  9. Multimodal imaging utilising integrated MR-PET for human brain tumour assessment

    International Nuclear Information System (INIS)

    Neuner, Irene; Kaffanke, Joachim B.; Langen, Karl-Josef; Kops, Elena Rota; Tellmann, Lutz; Stoffels, Gabriele; Weirich, Christoph; Filss, Christian; Scheins, Juergen; Herzog, Hans; Shah, N. Jon

    2012-01-01

    The development of integrated magnetic resonance (MR)-positron emission tomography (PET) hybrid imaging opens up new horizons for imaging in neuro-oncology. In cerebral gliomas the definition of tumour extent may be difficult to ascertain using standard MR imaging (MRI) only. The differentiation of post-therapeutic scar tissue, tumour rests and tumour recurrence is challenging. The relationship to structures such as the pyramidal tract to the tumour mass influences the therapeutic neurosurgical approach. The diagnostic information may be enriched by sophisticated MR techniques such as diffusion tensor imaging (DTI), multiple-volume proton MR spectroscopic imaging (MRSI) and functional MRI (fMRI). Metabolic imaging with PET, especially using amino acid tracers such as 18 F-fluoroethyl-l-tyrosine (FET) or 11 C-l-methionine (MET) will indicate tumour extent and response to treatment. The new technologies comprising MR-PET hybrid systems have the advantage of providing comprehensive answers by a one-stop-job of 40-50 min. The combined approach provides data of different modalities using the same iso-centre, resulting in optimal spatial and temporal realignment. All images are acquired exactly under the same physiological conditions. We describe the imaging protocol in detail and provide patient examples for the different imaging modalities such as FET-PET, standard structural imaging (T1-weighted, T2-weighted, T1-weighted contrast agent enhanced), DTI, MRSI and fMRI. (orig.)

  10. Multimodal imaging utilising integrated MR-PET for human brain tumour assessment

    Energy Technology Data Exchange (ETDEWEB)

    Neuner, Irene [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); RWTH Aachen University, Department of Psychiatry, Psychotherapy and Psychosomatics, Aachen (Germany); JARA-BRAIN-Translational Medicine, Aachen (Germany); Kaffanke, Joachim B. [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); MR-Transfer e.K., Wuppertal (Germany); Langen, Karl-Josef; Kops, Elena Rota; Tellmann, Lutz; Stoffels, Gabriele; Weirich, Christoph; Filss, Christian; Scheins, Juergen; Herzog, Hans [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); Shah, N. Jon [Institute of Neuroscience and Medicine 4, INM 4, Juelich (Germany); RWTH Aachen University, Department of Neurology, Aachen (Germany); JARA-BRAIN-Translational Medicine, Aachen (Germany)

    2012-12-15

    The development of integrated magnetic resonance (MR)-positron emission tomography (PET) hybrid imaging opens up new horizons for imaging in neuro-oncology. In cerebral gliomas the definition of tumour extent may be difficult to ascertain using standard MR imaging (MRI) only. The differentiation of post-therapeutic scar tissue, tumour rests and tumour recurrence is challenging. The relationship to structures such as the pyramidal tract to the tumour mass influences the therapeutic neurosurgical approach. The diagnostic information may be enriched by sophisticated MR techniques such as diffusion tensor imaging (DTI), multiple-volume proton MR spectroscopic imaging (MRSI) and functional MRI (fMRI). Metabolic imaging with PET, especially using amino acid tracers such as {sup 18}F-fluoroethyl-l-tyrosine (FET) or {sup 11}C-l-methionine (MET) will indicate tumour extent and response to treatment. The new technologies comprising MR-PET hybrid systems have the advantage of providing comprehensive answers by a one-stop-job of 40-50 min. The combined approach provides data of different modalities using the same iso-centre, resulting in optimal spatial and temporal realignment. All images are acquired exactly under the same physiological conditions. We describe the imaging protocol in detail and provide patient examples for the different imaging modalities such as FET-PET, standard structural imaging (T1-weighted, T2-weighted, T1-weighted contrast agent enhanced), DTI, MRSI and fMRI. (orig.)

  11. Generating patient specific pseudo-CT of the head from MR using atlas-based regression

    International Nuclear Information System (INIS)

    Sjölund, J; Forsberg, D; Andersson, M; Knutsson, H

    2015-01-01

    Radiotherapy planning and attenuation correction of PET images require simulation of radiation transport. The necessary physical properties are typically derived from computed tomography (CT) images, but in some cases, including stereotactic neurosurgery and combined PET/MR imaging, only magnetic resonance (MR) images are available. With these applications in mind, we describe how a realistic, patient-specific, pseudo-CT of the head can be derived from anatomical MR images. We refer to the method as atlas-based regression, because of its similarity to atlas-based segmentation. Given a target MR and an atlas database comprising MR and CT pairs, atlas-based regression works by registering each atlas MR to the target MR, applying the resulting displacement fields to the corresponding atlas CTs and, finally, fusing the deformed atlas CTs into a single pseudo-CT. We use a deformable registration algorithm known as the Morphon and augment it with a certainty mask that allows a tailoring of the influence certain regions are allowed to have on the registration. Moreover, we propose a novel method of fusion, wherein the collection of deformed CTs is iteratively registered to their joint mean and find that the resulting mean CT becomes more similar to the target CT. However, the voxelwise median provided even better results; at least as good as earlier work that required special MR imaging techniques. This makes atlas-based regression a good candidate for clinical use. (paper)

  12. MR findings of cyclosporine neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Po Song; Ahn, Kook Jin; Ahn, Bo Young; Jung, Hae An; Kim, Hee Je; Lee, Jae Mun [The Catholic Univ. St Mary' s Hospital, Seoul (Korea, Republic of)

    1998-12-01

    To analyze the MR findings of cyclosporine-induced neurotoxicity in patients receiving high dose of cyclosporine and to suggest the possible pathogenetic mechanism. The cases of seven patients (2 males, 5 females;18-36 years old) who suffered seizures after receiving high-dose cyclosporine for bone marrow transplantation due to diseases such as aplastic anemia or leukemia were retrospectively reviewed. We evaluated the location and pattern of abnormal signal intensity seen on T2 weighted images, the presence of contrast enhancement, and the changes seen on follow-up MR performed at intervals of 12-30 days after initial MR in five of seven patients. We analyzed levels of blood cyclosporine and magnesium, and investigated the presence of hypertension at the sity of the seizure. Locations of the lesions were bilateral(n=3D5), unilateral(n=3D2), parietal(n=3D6), occipital(n=3D6), temporal(n=3D4), and in the frontal lobe(n=3D3). Frontal lesions showed high signal intensities in the borderline ischemic zone of the frontal lobe between the territory of the anterior and middle cerebral arteries. In six of the seven patients, cortical and subcortical areas including subcortical U-fibers were seen on T2-weighted images to be involved in the parietooccipital lobes. Only one of the seven showed high signal intensity in the left basal ganglia. All lesions showed high signal intensity on T2-weighted images, and iso to low signal intensity on T1-weighted. In five of seven patients there was no definite enhancement, but in the other two, enhancement was slight. In four of seven patients seizures occurred within high therapeutic ranges(250-450ng/ml), while others suffered such attacks at levels below the therapeutic range. After cyclospirine was administered at a reduced dosage or stopped, follow-up MR images showed the complete or near-total disappearance of the abnormal findings previously described. Only two patients had hypertension, and the others normotension. Five of the

  13. MR findings of cyclosporine neurotoxicity

    International Nuclear Information System (INIS)

    Yang, Po Song; Ahn, Kook Jin; Ahn, Bo Young; Jung, Hae An; Kim, Hee Je; Lee, Jae Mun

    1998-01-01

    To analyze the MR findings of cyclosporine-induced neurotoxicity in patients receiving high dose of cyclosporine and to suggest the possible pathogenetic mechanism. The cases of seven patients (2 males, 5 females;18-36 years old) who suffered seizures after receiving high-dose cyclosporine for bone marrow transplantation due to diseases such as aplastic anemia or leukemia were retrospectively reviewed. We evaluated the location and pattern of abnormal signal intensity seen on T2 weighted images, the presence of contrast enhancement, and the changes seen on follow-up MR performed at intervals of 12-30 days after initial MR in five of seven patients. We analyzed levels of blood cyclosporine and magnesium, and investigated the presence of hypertension at the sity of the seizure. Locations of the lesions were bilateral(n=3D5), unilateral(n=3D2), parietal(n=3D6), occipital(n=3D6), temporal(n=3D4), and in the frontal lobe(n=3D3). Frontal lesions showed high signal intensities in the borderline ischemic zone of the frontal lobe between the territory of the anterior and middle cerebral arteries. In six of the seven patients, cortical and subcortical areas including subcortical U-fibers were seen on T2-weighted images to be involved in the parietooccipital lobes. Only one of the seven showed high signal intensity in the left basal ganglia. All lesions showed high signal intensity on T2-weighted images, and iso to low signal intensity on T1-weighted. In five of seven patients there was no definite enhancement, but in the other two, enhancement was slight. In four of seven patients seizures occurred within high therapeutic ranges(250-450ng/ml), while others suffered such attacks at levels below the therapeutic range. After cyclospirine was administered at a reduced dosage or stopped, follow-up MR images showed the complete or near-total disappearance of the abnormal findings previously described. Only two patients had hypertension, and the others normotension. Five of the

  14. Imaging evaluation of potential donors in living-donor liver transplantation

    International Nuclear Information System (INIS)

    Low, G.; Wiebe, E.; Walji, A.H.; Bigam, D.L.

    2008-01-01

    Liver transplants, originally obtained from deceased donors, can now be harvested from living donors as well. This technique, called living-donor liver transplantation (LDLT), provides an effective alternative means of liver transplantation and is a method of expanding the donor pool in light of the demand and supply imbalance for organ transplants. Imaging plays an important role in LDLT programmes by providing robust evaluation of potential donors to ensure that only anatomically suitable donors with no significant co-existing pathology are selected and that crucial information that allows detailed preoperative planning is available. Imaging evaluation helps to improve the outcome of LDLT for both donors and recipients, by improving the chances of graft survival and reducing the postoperative complication rate. In this review, we describe the history of LDLT and discuss in detail the application of imaging in donor assessment with emphasis on use of modern computed tomography (CT) and magnetic resonance imaging (MRI) techniques

  15. A strategy for multimodal deformable image registration to integrate PET/MR into radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Leibfarth, Sara; Moennich, David; Thorwarth, Daniela; Welz, Stefan; Siegel, Christine; Zips, Daniel; Schwenzer, Nina; Holger Schmidt, Holger

    2013-01-01

    Background: Combined positron emission tomography (PET)/magnetic resonance imaging (MRI) is highly promising for biologically individualized radiotherapy (RT). Hence, the purpose of this work was to develop an accurate and robust registration strategy to integrate combined PET/MR data into RT treatment planning. Material and methods: Eight patient datasets consisting of an FDG PET/computed tomography (CT) and a subsequently acquired PET/MR of the head and neck (HN) region were available. Registration strategies were developed based on CT and MR data only, whereas the PET components were fused with the resulting deformation field. Following a rigid registration, deformable registration was performed with a transform parametrized by B-splines. Three different optimization metrics were investigated: global mutual information (GMI), GMI combined with a bending energy penalty (BEP) for regularization (GMI + BEP) and localized mutual information with BEP (LMI + BEP). Different quantitative registration quality measures were developed, including volumetric overlap and mean distance measures for structures segmented on CT and MR as well as anatomical landmark distances. Moreover, the local registration quality in the tumor region was assessed by the normalized cross correlation (NCC) of the two PET datasets. Results: LMI + BEP yielded the most robust and accurate registration results. For GMI, GMI + BEP and LMI + BEP, mean landmark distances (standard deviations) were 23.9 mm (15.5 mm), 4.8 mm (4.0 mm) and 3.0 mm (1.0 mm), and mean NCC values (standard deviations) were 0.29 (0.29), 0.84 (0.14) and 0.88 (0.06), respectively. Conclusion: Accurate and robust multimodal deformable image registration of CT and MR in the HN region can be performed using a B-spline parametrized transform and LMI + BEP as optimization metric. With this strategy, biologically individualized RT based on combined PET/MRI in terms of dose painting is possible

  16. Hyaluronic acid-modified manganese-chelated dendrimer-entrapped gold nanoparticles for the targeted CT/MR dual-mode imaging of hepatocellular carcinoma

    Science.gov (United States)

    Wang, Ruizhi; Luo, Yu; Yang, Shuohui; Lin, Jiang; Gao, Dongmei; Zhao, Yan; Liu, Jinguo; Shi, Xiangyang; Wang, Xiaolin

    2016-09-01

    Hepatocellular carcinoma (HCC) is the most common malignant tumor of the liver. The early and effective diagnosis has always been desired. Herein, we present the preparation and characterization of hyaluronic acid (HA)-modified, multifunctional nanoparticles (NPs) targeting CD44 receptor-expressing cancer cells for computed tomography (CT)/magnetic resonance (MR) dual-mode imaging. We first modified amine-terminated generation 5 poly(amidoamine) dendrimers (G5.NH2) with an Mn chelator, 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA), fluorescein isothiocyanate (FI), and HA. Then, gold nanoparticles (AuNPs) were entrapped within the above raw product, denoted as G5.NH2-FI-DOTA-HA. The designed multifunctional NPs were formed after further Mn chelation and purification and were denoted as {(Au0)100G5.NH2-FI-DOTA(Mn)-HA}. These NPs were characterized via several different techniques. We found that the {(Au0)100G5.NH2-FI-DOTA(Mn)-HA} NPs exhibited good water dispersibility, stability under different conditions, and cytocompatibility within a given concentration range. Because both AuNPs and Mn were present in the product, {(Au0)100G5.NH2-FI-DOTA(Mn)-HA} displayed a high X-ray attenuation intensity and favorable r1 relaxivity, which are advantageous properties for targeted CT/MR dual-mode imaging. This approach was used to image HCC cells in vitro and orthotopically transplanted HCC tumors in a unique in vivo model through the CD44 receptor-mediated endocytosis pathway. This work introduces a novel strategy for preparing multifunctional NPs via dendrimer nanotechnology.

  17. MR and CT imaging patterns in post-varicella encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Darling, C.F. [Div. of Neuroimaging, Children`s Memorial Center, Northwestern Univ. Medical School, Chicago, IL (United States); Larsen, M.B. [Div. of Neurology, Children`s Memorial Center, Northwestern Univ. Medical School, Chicago, IL (United States); Byrd, S.E. [Div. of Neuroimaging, Children`s Memorial Center, Northwestern Univ. Medical School, Chicago, IL (United States); Radkowski, M.A. [Div. of Neuroimaging, Children`s Memorial Center, Northwestern Univ. Medical School, Chicago, IL (United States); Palka, P.S. [Div. of Neuroimaging, Children`s Memorial Center, Northwestern Univ. Medical School, Chicago, IL (United States); Allen, E.D. [Div. of Neuroimaging, Children`s Memorial Center, Northwestern Univ. Medical School, Chicago, IL (United States)

    1995-06-01

    The aim of the investigation was to determine the patterns of cerebral involvement on computed tomography (CT) and magnetic resonance (MR) imaging in post-varicella encephalitis. Four children between the ages of 2 and 11 years presented over a 5-year period with a diagnosis of post-varicella encephalitis. Their imaging studies and clinical data were reviewed retrospectively. The medical histories of all four children were noncontributory except for recent bouts of chickenpox 1 week to 3 months prior to hospitalization. Three children presented with parkinsonian manifestations. Bilateral, symmetric hypodense, nonenhancing basal ganglia lesions were found on CT. These areas showed nonenhancing low signal intensity on T1-weighted images and high signal intensity on T2-weighted images on MR. One child presented with diffuse, multiple gray and white matter lesions of similar imaging characteristics; some lesions, however, did enhance. This child had no gait disturbances. Post-varicella encephalitis can produce two patterns of dramatic CT and MR findings. With an appropriate history and clinical findings, varicella as a cause of bilateral basal ganglia or diffuse cerebral lesions can be differentiated from other possible etiologies which include trauma, anoxia, metabolic disorders and demyelinating diseases. (orig.)

  18. Nutzerorientiertes Management von materiellen und immateriellen Informationsobjekten

    OpenAIRE

    Hübsch, Chris

    2001-01-01

    Schaffung einer stabilen, erweiterbaren und skalierbaren Infrastruktur für die Bereitstellung von Diensten im Umfeld von Bibliotheken und ähnlichen wissensanbietenden Einrichtungen unter Verwendung von XML-RPC und Python.

  19. MR-CBCT image-guided system for radiotherapy of orthotopic rat prostate tumors.

    Directory of Open Access Journals (Sweden)

    Tsuicheng D Chiu

    Full Text Available Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT imaging alone. In this study, we characterized a research magnetic resonance (MR scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This

  20. MR-CBCT image-guided system for radiotherapy of orthotopic rat prostate tumors.

    Science.gov (United States)

    Chiu, Tsuicheng D; Arai, Tatsuya J; Campbell Iii, James; Jiang, Steve B; Mason, Ralph P; Stojadinovic, Strahinja

    2018-01-01

    Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT) imaging alone. In this study, we characterized a research magnetic resonance (MR) scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV) was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This novel protocol

  1. Die Verteilung und Eigenschaften von Bodenformen in der Deutschen Bucht, eine Rekonstruktion der Karten von Ulrich (1973)

    DEFF Research Database (Denmark)

    Winter, Christian; Lefebvre, Alice; Benninghoff, Markus

    2015-01-01

    Entstehung, Gestalt und Dynamik von Bodenformen in vergleichsweise kleinen Untersuchungsgebieten ist die Arbeit von ULRICH (1973) über die Verteilung von Bodenformen in der Deutschen Bucht bis heute die einzige verfügbare zusammenhängende Darstellung für die deutsche Nordseeküste. Die analogen Karten und die...

  2. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET

  3. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  4. ˝FLUMINENSIA˝ VON FRAN KURELAC

    Directory of Open Access Journals (Sweden)

    Leopoldina Veronika Banaš

    1990-01-01

    Full Text Available Das Buch "Fluminensia" (1862 von Fran Kurelac enthält die für die Schulfestlichkeiten geschriebenen Reden, Gelegenheitsgedichte - Ehrengedichte den bedeutenden und verdienstvollen Zeitgenossen gewidmet: dem Bischof von Senj und Modrus" Mirko Ožegović, Bartol Zmajic von Bakar, dem kroatischen Ban Josip Jelačić u.a. Danach folgen Aufrufe ("Proglasi" aus stürmischem 1848, gerichtet auf die Granzlandbewohner, Deutscher, ungarische Kroaten, Rumänen und Slawonier. Die Aufrufe wurden von Kurelac im Namen der Banalregierung beschrieben. Am Ende des Buches steht eine sprachwissenschaftliche Abhandlung über die ubstantivbiegung. Die für die Schulfestlichkeiten geschreibenen Reden sind wissenschaftliche Inhalte, essaystisch-didaktisch gestalltet, mit der Meldung über die Bedeutung der Wisenschaft, über die Bedeutung und Rolle der Sprache und des Buches für den Fortschritt des Volkes. Der Verfasser widmete dieses Buch seinen ehemaligen Schülern. "Fluminensia" nimmt eine wichtige Stelle in literarischer und sprachwissenschaftlicher Schöpfung auf dem Gebiet von Rijeka und Kroatien im 19. Jahrhundert ein.

  5. Non-invasive estimation of intracranial pressure. MR-based evaluation in children with hydrocephalus; Nichtinvasive Bestimmung des intrakraniellen Drucks. MR-basierte Untersuchung bei Kindern mit Hydrozephalus

    Energy Technology Data Exchange (ETDEWEB)

    Muehlmann, M.; Steffinger, D.; Ertl-Wagner, B.; Koerte, I.K. [Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Peraud, A. [Ludwig-Maximilians-Universitaet Muenchen, Abteilung fuer Neurochirurgie, Muenchen (Germany); Lehner, M. [Dr. von Haunersches Kinderspital, Ludwig-Maximilians-Universitaet Muenchen, Abteilung fuer Kinderchirurgie, Muenchen (Germany); Heinen, F.; Alperin, N. [University Miami, Department of Radiology, Miller School of Medicine, Miami (United States)

    2012-09-15

    The intracranial pressure (ICP) is a crucially important parameter for diagnostic and therapeutic decision-making in patients with hydrocephalus. So far there is no standard method to non-invasively assess the ICP. Various approaches to obtain the ICP semi-invasively or non-invasively are discussed and the clinical application of a magnetic resonance imaging (MRI)-based method to estimate ICP (MR-ICP) is demonstrated in a group of pediatric patients with hydrocephalus. Arterial inflow, venous drainage and craniospinal cerebrospinal fluid (CSF) flow were quantified using phase-contrast imaging to derive the MR-ICP. A total of 15 patients with hydrocephalus (n=9 treated with shunt placement or ventriculostomy) underwent MRI on a 3 T scanner applying retrospectively-gated cine phase contrast sequences. Of the patients six had clinical symptoms indicating increased ICP (age 2.5-14.61 years, mean 7.4 years) and nine patients had no clinical signs of elevated ICP (age 2.1-15.9 years; mean 9.8 years; all treated with shunt or ventriculostomy). Median MR-ICP in symptomatic patients was 24.5 mmHg (25th percentile 20.4 mmHg; 75th percentile 44.6 mmHg). Median MR-ICP in patients without acute signs of increased ICP was 9.8 mmHg (25th percentile 8.6 mmHg; 75th percentile 11.4 mmHg). Group differences were significant (p < 0.001; Mann-Whitney U-test). The MR-ICP technique is a promising non-invasive tool for estimating ICP. Further studies in larger patient cohorts are warranted to investigate its application in children with hydrocephalus. (orig.) [German] Der intrakranielle Druck (''intracranial pressure'' - ICP) ist ein entscheidender Parameter bei der Diagnostik, Therapie und Verlaufsbeurteilung von Patienten mit Hydrozephalus. Derzeit gibt es keine radiologische Standardmethode, um den intrakraniellen Druck quantitativ zu bestimmen. Methoden zur invasiven und nichtinvasiven Einschaetzung des ICP werden diskutiert und die Anwendung eines MR

  6. Functional MR mapping of higher cognitive brain functions; Neurofunktionelle MR-Bildgebung hoeherer kognitiver Leistungen des menschlichen Gehirns

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, M E [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie; Spitzer, M [Psychiatrische Universitaetsklinik, Heidelberg (Germany). Sektion Experimentelle Psychopathologie; Brix, G [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie; Kammer, T [Psychiatrische Universitaetsklinik, Heidelberg (Germany). Sektion Experimentelle Psychopathologie; Loose, R [Heidelberg Univ., Mannheim (Germany). Inst. fuer Klinische Radiologie; Schwartz, A [Heidelberg Univ., Mannheim (Germany). Neurologische Klinik; Gueckel, F [Heidelberg Univ., Mannheim (Germany). Inst. fuer Klinische Radiologie

    1995-04-01

    Fifteen normal subjects were examined on a conventional 1.5-T MR system to visualize cortical activation during the performance of high-level cognitive tasks. A computer-controlled videoprojector was employed to present psychometrically optimized activation paradigms. Reaction times and error rates of the volunteers were acquired online during stimulus presentation. The time course of cortical activation was measured in a series of strongly T{sub 2}*-weighted gradient-echo images from three or four adjacent slices. For anatomical correlation, picture elements showing a stimulus-related significant signal increase were color-coded and superimposed on T{sub 1}-weighted spin-echo images. Analysis of the fMRI data revealed a subtle (range 2-5%), but statistically significant increase in signal intensity during the periods of induced cortical activation. Judgment of semantic relatedness of word pairs, for example, activated selectively cortical areas in left frontal and left temporal brain regions. The strength of cortex activation in the semantic task decreased significantly in the course of stimulus presentation and was paralleled by a decrease in the corresponding reaction times. With its move into the area of cognitive neuroscience, fMRI calls both for the careful design of activation schemes and for the acquisition of behavioral data. For example, brain regions involved in language processing could only be identified clearly when psychometrically matched activation paradigms were employed. The reaction time data correlated well with selective learning and thus helped to facilitate interpretation of the fMRI data sets. (orig.) [Deutsch] Zur Abbildung kortikaler Strukturen, die durch die Bearbeitung hoeherer kognitiver Aufgaben aktiviert werden, wurden 15 gesunde Probanden an einem konventionellen 1,5-Tesla-MR-System untersucht. Psychometrisch optimierte Aktivierungsparadigmen wurden rechnergesteuert praesentiert und gleichzeitig Reaktionszeiten und Fehlerraten der

  7. Entwicklung von Methoden zur ereignisgesteuerten neurofunktionellen Kernspintomographie für die Messung der Gehirnaktivität bei der Schmerzverarbeitung

    OpenAIRE

    Meyer, Heiko

    2000-01-01

    Die ereignisgesteuerte neurofunktionelle Magnetresonanz-Tomographie ermöglicht die Darstellung der aktiven Gehirnareale, indem sie die unterschiedlichen magnetischen Eigenschaften von oxygeniertem und desoxygeniertem Blut ausnutzt. Im Rahmen dieser Arbeit wurden vier ereignisgesteuerte FLASH-Meßsequenzen für die Untersuchung der Schmerzverarbeitung entwickelt und implementiert. Diese Methoden ermöglichen die Abbildung der Gehirnfunktion auf einen äußeren Reiz mit hoher zeitlicher und räum...

  8. Allogeneic bone marrow transplantation with conditioning regimen of total body irradiation/busulfan/melphalan for 16 patients in children with high-risk leukemia and lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, Takao; Fujii, Noriko [Matsushita Memorial Hospital, Moriguchi, Osaka (Japan); Naya, Mayumi [and others

    1999-02-01

    We report the therapeutic results of allogeneic bone marrow transplantations (BMT) for 16 children with high-risk leukemia and lymphoma. The conditioning regimen consisted of total body irradiation (TBI) (12 Gy), busulfan (Bu) (4 mg/kg x 2 days), and melphalan (L-PAM) (70 mg/m{sup 2} x 2 or 3 days). Graft-versus-host disease (GVHD) prophylaxis was performed with cyclosporin (CsA) + methotrexate (MTX) (4 cases) and CsA + MTX-methyl-prednisolone (11 cases). Seven patients had acute lymphocytic leukemia, 6 acute nonlymphocytic leukemia, 2 B-cell type non-Hodgkin`s lymphoma, and 1 peripheral T-cell lymphoma. Nine patients were in complete remission (CR) and 7 in non CR at BMT. Nine patients received transplants from HLA-matched related (MR) donors, 4 from HLA-mismatched related (MisR) donors, and 3 from unrelated (UR) donors. Seven of the cases, all of which were transplanted from MR, have continued complete remission for 15-47 (median 27) months. Nine patients, of which seven were transplanted from MisR/UR, died from complications from fungal pneumonia (3), cytomegalovirus pneumonitis (1), GVHD (1), rhabdomyolysis (1), lymphoproliferative disorder (1), rejection (1), and relapse (1). These results suggest that the combination of TBI, Bu, and L-PAM as a BMT regimen has a significant anti-neoplastic benefit and is considered to be useful; however, considering the high rate of fatal transplant-related complications, more refinement is required, especially for transplants from MisR and UR donors. (author)

  9. Allogeneic bone marrow transplantation with conditioning regimen of total body irradiation/busulfan/melphalan for 16 patients in children with high-risk leukemia and lymphoma

    International Nuclear Information System (INIS)

    Yoshihara, Takao; Fujii, Noriko; Naya, Mayumi

    1999-01-01

    We report the therapeutic results of allogeneic bone marrow transplantations (BMT) for 16 children with high-risk leukemia and lymphoma. The conditioning regimen consisted of total body irradiation (TBI) (12 Gy), busulfan (Bu) (4 mg/kg x 2 days), and melphalan (L-PAM) (70 mg/m 2 x 2 or 3 days). Graft-versus-host disease (GVHD) prophylaxis was performed with cyclosporin (CsA) + methotrexate (MTX) (4 cases) and CsA + MTX-methyl-prednisolone (11 cases). Seven patients had acute lymphocytic leukemia, 6 acute nonlymphocytic leukemia, 2 B-cell type non-Hodgkin's lymphoma, and 1 peripheral T-cell lymphoma. Nine patients were in complete remission (CR) and 7 in non CR at BMT. Nine patients received transplants from HLA-matched related (MR) donors, 4 from HLA-mismatched related (MisR) donors, and 3 from unrelated (UR) donors. Seven of the cases, all of which were transplanted from MR, have continued complete remission for 15-47 (median 27) months. Nine patients, of which seven were transplanted from MisR/UR, died from complications from fungal pneumonia (3), cytomegalovirus pneumonitis (1), GVHD (1), rhabdomyolysis (1), lymphoproliferative disorder (1), rejection (1), and relapse (1). These results suggest that the combination of TBI, Bu, and L-PAM as a BMT regimen has a significant anti-neoplastic benefit and is considered to be useful; however, considering the high rate of fatal transplant-related complications, more refinement is required, especially for transplants from MisR and UR donors. (author)

  10. Von der Vielfalt einer Institution

    OpenAIRE

    Kabaum, Marcel; Buck, Marc Fabian

    2013-01-01

    Von der Vielfalt von Universitäten bzw. higher education institutions (HEIs) zu sprechen heißt, sich dem Dickicht an Komplexität zu stellen, das sich zwischen ihren Ideen und Realitäten ausbreitet. Der Text führt in den Sammelband "Ideen und Realitäten von Universitäten" ein und hebt die verschiedenen disziplinären Sichtweisen sowie die internationale Breite - Deutschland, Südamerika, USA, Afghanistan und China - der Beiträge hervor. (DIPF/Orig.)

  11. Potential clinical applications of {sup 18}F-fluorodeoxyglucose position emission tomography/magnetic resonance mammography in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Kong, Eun Jung [Dept. of Nuclear Medicine, Yeugnam University Hospital, Daegu (Korea, Republic of)

    2017-09-15

    The whole-body positron emission tomography (PET)/magnetic resonance (MR) scan is a cutting edge technology providing comprehensive structural information from MR imaging and functional features from PET in a single session. Recent research findings and clinical experience have shown that 18F-fluorodeoxyglucose (FDG) whole-body PET/MR imaging has a diagnostic performance comparable with or superior to that of PET/CT in the field of oncology, including for breast cancer. In particular, FDG PET/MR mammography in the prone position with the breast hanging in a pendant manner can provide more comprehensive information about the metabolism, anatomy, and functional features of a breast lesion than a whole-body PET/MR scan. This article reports on current state-of-the-art PET/MR mammography in patients with breast cancer and the prospects for potential application in the future.

  12. Response assessment of stereotactic body radiation therapy using dynamic contrast-enhanced integrated MR-PET in non-small cell lung cancer patients.

    Science.gov (United States)

    Huang, Yu-Sen; Chen, Jenny Ling-Yu; Hsu, Feng-Ming; Huang, Jei-Yie; Ko, Wei-Chun; Chen, Yi-Chang; Jaw, Fu-Shan; Yen, Ruoh-Fang; Chang, Yeun-Chung

    2018-01-01

    To evaluate the response in patients undergoing SBRT using dynamic contrast-enhanced (DCE) integrated magnetic resonance positron emission tomography (MR-PET). Stereotactic body radiation therapy (SBRT) is efficacious as a front-line local treatment for non-small cell lung cancer (NSCLC). We prospectively enrolled 19 lung tumors in 17 nonmetastatic NSCLC patients who were receiving SBRT as a primary treatment. They underwent DCE-integrated 3T MR-PET before and 6 weeks after SBRT. The following image parameters were analyzed: tumor size, standardized uptake value (SUV), apparent diffusion coefficient, K trans , k ep , v e , v p , and iAUC 60 . Chest computed tomography (CT) was performed at 3 months after SBRT. SBRT treatment led to tumor changes including significant decreases in the SUV max (-61%, P PET SUV max was correlated with the MR k ep mean (P = 0.002) and k ep SD (P 10 (P = 0.083). In patients with NSCLC who are receiving SBRT, DCE-integrated MR-PET can be used to evaluate the response after SBRT and to predict the local treatment outcome. 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:191-199. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Beeinflussung der Wirkung von Ernährungsinformation durch Framing: Analyse am Beispiel von Folsäure

    OpenAIRE

    Lensch, Kathrin; Hartmann, Monika; Simons, Johannes

    2011-01-01

    Die Bereitstellung und verbrauchergerechte Aufbereitung von Informationen stellt eine Möglichkeit dar, Konsumenten darin zu unterstützen, Gesundheitsaspekte vermehrt in das Kauf- und Essverhalten zu integrieren. In der Verhaltensökonomik gelten Framing-Effekte als wichtige Bestimmungsfaktoren für die Wahrnehmung von Informationen. Im Rahmen des vorliegenden Beitrags werden Framing-Effekte am Beispiel von Ernährungsinformationen über Folsäure mit Hilfe eines Experiments untersucht. Die Ergebni...

  14. Der Einfluss von sozialer Ungleichheit und kulturellen Unterschieden auf die Wahrnehmung von finanziellen und Arbeitsplatzrisiken: Überlegungen zur Risikogesellschaft

    OpenAIRE

    Abbott, David; Quilgars, Deborah; Jones, Anwen

    2006-01-01

    Der vorliegende Artikel beruht auf Daten einer Studie, die sich mit der Frage beschäftigt, wie verschiedene soziale und kulturelle Gruppen die Risiken von Einkommens- und Arbeitsplatzverlust wahrnehmen und darauf reagieren. Autoren wie LASH, DOUGLAS und LUPTON betonten die Bedeutung von Gruppenzugehörigkeit und sozialen Kategorien für die Strukturierung der Reaktionsweisen auf verschiedene Risikoarten. Sie sprechen daher lieber von Risikokulturen als von der Risikogesellschaft. Trotzdem erken...

  15. Preoperative computed tomography volumetry and graft weight estimation in adult living donor liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Pinheiro, Rafael S.; Cruz Junior, Ruy J.; Andraus, Wellington; Ducatti, Liliana; Martino, Rodrigo B.; Nacif, Lucas S.; Rocha-Santos, Vinicius; Arantes, Rubens M.; D' Albuquerque, Luiz A.C., E-mail: rsnpinheiro@gmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Dept. de Gastroenterologia. Div. de Transplante de Orgaos do Aparelho Digestivo; Lai, Quirino [Universidade de L' Aquila, San Salvatore Hospital (Italy); Ibuki, Felicia S.; Rocha, Manoel S. [Universidade de Sao Paulo (USP), SP (Brazil). Departamento de Radiologia

    2017-09-01

    Background: Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. Aim: To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Methods: Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Results: Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r{sup 2} =0.98, slope=0.47, standard deviation of 0.024 and p<0.0001). Spearman Linear correlation was 0.65 with 95% CI of 0.45 – 0.99 (p<0.0001). Conclusion: The one-to-one rule did not applied in patients with normal liver parenchyma. A better estimation of graft weight could be reached by multiplying estimated graft volume by 0.82. (author)

  16. Preoperative computed tomography volumetry and graft weight estimation in adult living donor liver transplantation

    International Nuclear Information System (INIS)

    Pinheiro, Rafael S.; Cruz Junior, Ruy J.; Andraus, Wellington; Ducatti, Liliana; Martino, Rodrigo B.; Nacif, Lucas S.; Rocha-Santos, Vinicius; Arantes, Rubens M.; D'Albuquerque, Luiz A.C.; Ibuki, Felicia S.; Rocha, Manoel S.

    2017-01-01

    Background: Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. Aim: To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Methods: Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Results: Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r"2 =0.98, slope=0.47, standard deviation of 0.024 and p<0.0001). Spearman Linear correlation was 0.65 with 95% CI of 0.45 – 0.99 (p<0.0001). Conclusion: The one-to-one rule did not applied in patients with normal liver parenchyma. A better estimation of graft weight could be reached by multiplying estimated graft volume by 0.82. (author)

  17. PREOPERATIVE COMPUTED TOMOGRAPHY VOLUMETRY AND GRAFT WEIGHT ESTIMATION IN ADULT LIVING DONOR LIVER TRANSPLANTATION

    Science.gov (United States)

    PINHEIRO, Rafael S.; CRUZ-JR, Ruy J.; ANDRAUS, Wellington; DUCATTI, Liliana; MARTINO, Rodrigo B.; NACIF, Lucas S.; ROCHA-SANTOS, Vinicius; ARANTES, Rubens M; LAI, Quirino; IBUKI, Felicia S.; ROCHA, Manoel S.; D´ALBUQUERQUE, Luiz A. C.

    2017-01-01

    ABSTRACT Background: Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. Aim: To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Methods: Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Results: Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r2=0.98, slope=0.47, standard deviation of 0.024 and p<0.0001). Spearman Linear correlation was 0.65 with 95% CI of 0.45 - 0.99 (p<0.0001). Conclusion: The one-to-one rule did not applied in patients with normal liver parenchyma. A better estimation of graft weight could be reached by multiplying estimated graft volume by 0.82. PMID:28489167

  18. MR findings in patients with disabling musculocutaneous chronic graft-versus-host disease

    Energy Technology Data Exchange (ETDEWEB)

    Horger, M.; Boss, A.; Claussen, C.D. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Bethge, W.; Faul, C.; Vogel, W. [Eberhard-Karls-University, Department of Internal Medicine-Oncology, Tuebingen (Germany); Fierlbeck, G. [Eberhard-Karls-University, Department of Dermatology, Tuebingen (Germany); Bornemann, A. [Eberhard-Karls-University, Insitute for Brain Research, Tuebingen (Germany)

    2008-10-15

    To describe musculocutaneous MR-findings responsible for disability in chronic graft-versus-host disease (cGVHD) after allogeneic hematopoietic cell transplantation (HCT). Between June 2005 and February 2008, we performed whole-body musculoskeletal magnetic resonance imaging (MRI; n = 12) or regional MRI (n = 4) in 16 consecutive patients presenting with disabling sclerodermatous cGVHD (e.g., skin edema, fixed deep dermal sclerosis, joint contractures, painful muscular contractures, or myalgia). In all patients, MRI showed musculocutaneous abnormalities reflecting different degrees of inflammation and collagen tissue involvement of the skin (n = 10), subcutaneous fat tissue (n = 13), muscle fasciae (n = 16), subfascial muscular septae (n = 6), or findings compatible with myositis (n = 3). The most frequently involved muscle fasciae comprised those of the vastus lateralis muscle (n = 12), biceps femoris muscle (n = 11), gastrocnemius medialis muscle (n = 8), serratus anterior muscle, and latissimus dorsi muscle (each, n = 5). Increased signal of involved tissues on STIR-images and fat-saturated postgadolinium T1-weighted images represented the most frequent MR-signal abnormalities. MR imaging of musculocutaneous cGVHD allows accurate evaluation including assessment of deep tissue infiltration and assists in the differential diagnosis. (orig.)

  19. MR findings in patients with disabling musculocutaneous chronic graft-versus-host disease

    International Nuclear Information System (INIS)

    Horger, M.; Boss, A.; Claussen, C.D.; Bethge, W.; Faul, C.; Vogel, W.; Fierlbeck, G.; Bornemann, A.

    2008-01-01

    To describe musculocutaneous MR-findings responsible for disability in chronic graft-versus-host disease (cGVHD) after allogeneic hematopoietic cell transplantation (HCT). Between June 2005 and February 2008, we performed whole-body musculoskeletal magnetic resonance imaging (MRI; n = 12) or regional MRI (n = 4) in 16 consecutive patients presenting with disabling sclerodermatous cGVHD (e.g., skin edema, fixed deep dermal sclerosis, joint contractures, painful muscular contractures, or myalgia). In all patients, MRI showed musculocutaneous abnormalities reflecting different degrees of inflammation and collagen tissue involvement of the skin (n = 10), subcutaneous fat tissue (n 13), muscle fasciae (n = 16), subfascial muscular septae (n = 6), or findings compatible with myositis (n = 3). The most frequently involved muscle fasciae comprised those of the vastus lateralis muscle (n = 12), biceps femoris muscle (n = 11), gastrocnemius medialis muscle (n = 8), serratus anterior muscle, and latissimus dorsi muscle (each, n = 5). Increased signal of involved tissues on STIR-images and fat-saturated postgadolinium T1-weighted images represented the most frequent MR-signal abnormalities. MR imaging of musculocutaneous cGVHD allows accurate evaluation including assessment of deep tissue infiltration and assists in the differential diagnosis. (orig.)

  20. Image-guided modified deep anterior lamellar keratoplasty (DALK) corneal transplant using intraoperative optical coherence tomography

    Science.gov (United States)

    Tao, Yuankai K.; LaBarbera, Michael; Ehlers, Justis P.; Srivastava, Sunil K.; Dupps, William J.

    2015-03-01

    Deep anterior lamellar keratoplasty (DALK) is an alternative to full-thickness corneal transplant and has advantages including the absence of allograft rejection; shortened duration of topical corticosteroid treatment and reduced associated risk of glaucoma, cataract, or infection; and enables use of grafts with poor endothelial quality. DALK begins by performing a trephination of approximately 80% stromal thickness, as measured by pachymetry. After removal of the anterior stoma, a needle is inserted into the residual stroma to inject air or viscoelastic to dissect Descemet's membrane. These procedures are inherently difficult and intraoperative rates of Descemet's membrane perforation between 4-39% have been reported. Optical coherence tomography (OCT) provides high-resolution images of tissue microstructures in the cornea, including Descemet's membrane, and allows quantitation of corneal layer thicknesses. Here, we use crosssectional intraoperative OCT (iOCT) measurements of corneal thickness during surgery and a novel micrometeradjustable biopsy punch to precision-cut the stroma down to Descemet's membrane. Our prototype cutting tool allows us to establish a dissection plane at the corneal endothelium interface, mitigates variability in cut-depths as a result of tremor, reduces procedure complexity, and reduces complication rates. iOCT-guided modified DALK procedures were performed on 47 cadaveric porcine eyes by non-experts and achieved a perforation rate of ~5% with a mean corneal dissection time care.

  1. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Togni Filho, Paulo Henrique; Casagrande, Joao Luiz Marin; Lederman, Henrique Manoel, E-mail: paulotognifilho@gmail.com [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Dept. of Diagnostico por Imagem; Universidade de Sao Paulo (InRad/HC/FMUSP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Instituto de Radiologia

    2017-03-15

    Objective: To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods: This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results: A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion: In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. (author)

  2. Utility of the inspiratory phase in high-resolution computed tomography evaluations of pediatric patients with bronchiolitis obliterans after allogeneic bone marrow transplant: reducing patient radiation exposure

    International Nuclear Information System (INIS)

    Togni Filho, Paulo Henrique; Casagrande, Joao Luiz Marin; Lederman, Henrique Manoel; Universidade de Sao Paulo

    2017-01-01

    Objective: To evaluate the utility of the inspiratory phase in high-resolution computed tomography (HRCT) of the chest for the diagnosis of post-bone marrow transplantation bronchiolitis obliterans. Materials and Methods: This was a retrospective, observational, cross-sectional study. We selected patients of either gender who underwent bone marrow transplantation and chest HRCT between March 1, 2002 and December 12, 2014. Ages ranged from 3 months to 20.7 years. We included all examinations in which the HRCT was performed appropriately. The examinations were read by two radiologists, one with extensive experience in pediatric radiology and another in the third year of residency, who determined the presence or absence of the following imaging features: air trapping, bronchiectasis, alveolar opacities, nodules, and atelectasis. Results: A total of 222 examinations were evaluated (mean, 5.4 ± 4.5 examinations per patient). The expiratory phase findings were comparable to those obtained in the inspiratory phase, except in one patient, in whom a small uncharacteristic nodule was identified only in the inspiratory phase. Air trapping was identified in a larger number of scans in the expiratory phase than in the inspiratory phase, as was atelectasis, although the difference was statistically significant only for air trapping. Conclusion: In children being evaluated for post-bone marrow transplantation bronchiolitis obliterans, the inspiratory phase can be excluded from the chest HRCT protocol, thus reducing by half the radiation exposure in this population. (author)

  3. Neurological complications following liver transplant: a pictorial review of radiological and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Kyung; Shin, Ji Hoon; Kim, Sang Joon; Lee, Deok Hee; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul [University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2005-07-15

    Neurological complications are a rare but important and significant source of information about morbidity and mortality in liver transplant patients. Based on the clinical and radiological findings of 21 patients, neurological complications were categorized into five main groups; focal hemorrhagic or occlusive complications (n=11); diffuse hypoxic-ischemic injury (n=3); hypertensive encephalopathy (n=1); central pontine or extra-pontine myelinolysis (n=4); and infection (n=2). Neurological manifestations varied according to the location of the lesion, although seizures were the most common manifestation. In this pictorial review, we illustrate the radiological findings, focusing on MR and CT images, of a spectrum of neurological complications following liver transplants, as well as their clinical correlations.

  4. Neurological complications following liver transplant: a pictorial review of radiological and clinical findings

    International Nuclear Information System (INIS)

    Lee, Young Kyung; Shin, Ji Hoon; Kim, Sang Joon; Lee, Deok Hee; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul

    2005-01-01

    Neurological complications are a rare but important and significant source of information about morbidity and mortality in liver transplant patients. Based on the clinical and radiological findings of 21 patients, neurological complications were categorized into five main groups; focal hemorrhagic or occlusive complications (n=11); diffuse hypoxic-ischemic injury (n=3); hypertensive encephalopathy (n=1); central pontine or extra-pontine myelinolysis (n=4); and infection (n=2). Neurological manifestations varied according to the location of the lesion, although seizures were the most common manifestation. In this pictorial review, we illustrate the radiological findings, focusing on MR and CT images, of a spectrum of neurological complications following liver transplants, as well as their clinical correlations

  5. Redoxspeziation von endlagerrelevanten Elementen mit Hilfe von Trennmethoden gekoppelt an ein Massenspektrometer mit induktiv gekoppeltem Plasma

    OpenAIRE

    Graser, Carl-Heinrich

    2015-01-01

    Im Rahmen dieser Arbeit wurden Redoxspeziationsanalysen von Eisen, Neptunium und Plutonium per CE-SF-ICP-MS durchgeführt. Durch Optimierung der Trennparameter konnten Trennungen der Pu Oxidationsstufen III bis VI und Trennungen der Np Oxidationsstufen IV bis VI binnen 15 Minuten mit einer Nachweisgrenze von 10-12 M durchgeführt werden. Die Trennung der Fe Oxidationsstufen II und III gelang in weniger als 5 Minuten mit einer Nachweisgrenze von 5-10-8 M.

  6. Assessment of cancellous bone mechanical properties from micro-FE models based on micro-CT, pQCT and MR images.

    NARCIS (Netherlands)

    Rietbergen, van B.; Majumdar, S.; Pistoia, W.; Newitt, D.C.; Kothari, M.; Laib, A.; Rüegsegger, P.

    1998-01-01

    Recently, new micro-finite element (micro-FE) techniques have been introduced to calculate cancellous bone mechanical properties directly from high-resolution images of its internal architecture. Also recently, new peripheral quantitative computed tomography (pQCT) and magnetic resonance (MR)

  7. Qualitative and Quantitative Evaluation of Blob-Based Time-of-Flight PET Image Reconstruction in Hybrid Brain PET/MR Imaging

    NARCIS (Netherlands)

    Leemans, Eva L.; Kotasidis, Fotis; Wissmeyer, Michael; Garibotto, Valentina; Zaidi, Habib

    2015-01-01

    Many neurological diseases affect small structures in the brain and, as such, reliable visual evaluation and accurate quantification are required. Recent technological developments made the clinical use of hybrid positron emission tomography/magnetic resonance (PET/MR) systems possible, providing

  8. Medien und Berufsvorstellungen von Kindern: eine experimentelle Studie zum Einfluss von Kinderbüchern auf das Berufsspektrum von Kindergartenkindern

    OpenAIRE

    Brüggemann, Tim; Gehrau, Volker; Handrup, Jutta

    2015-01-01

    "Der Beitrag thematisiert zunächst den Stand der beruflichen Orientierung von Jugendlichen sowie die pädagogischen Bemühungen beim Übergang Schule-Beruf, insbesondere im Hinblick auf eine Erweiterung des häufig engen Spektrums von Berufen, die bei der Berufswahl berücksichtig werden. Dabei richten sich die Bestrebungen, diesem Problem entgegenzuwirken, bislang vor allem auf Jugendliche. Anschließend wird anhand vorliegender Ergebnisse aus der Medienforschung diskutiert, in welcher Weise Masse...

  9. Accuracy evaluation of fusion of CT, MR, and SPECT images using commercially available software packages (SRS PLATO and IFS)

    International Nuclear Information System (INIS)

    Mongioj, Valeria; Brusa, Anna; Loi, Gianfranco; Pignoli, Emanuele; Gramaglia, Alberto; Scorsetti, Marta; Bombardieri, Emilio; Marchesini, Renato

    1999-01-01

    Purpose: A problem for clinicians is to mentally integrate information from multiple diagnostic sources, such as computed tomography (CT), magnetic resonance (MR), and single photon emission computed tomography (SPECT), whose images give anatomic and metabolic information. Methods and Materials: To combine this different imaging procedure information, and to overlay correspondent slices, we used commercially available software packages (SRS PLATO and IFS). The algorithms utilize a fiducial-based coordinate system (or frame) with 3 N-shaped markers, which allows coordinate transformation of a clinical examination data set (9 spots for each transaxial section) to a stereotactic coordinate system. The N-shaped markers were filled with fluids visible in each modality (gadolinium for MR, calcium chloride for CT, and 99m Tc for SPECT). The frame is relocatable, in the different acquisition modalities, by means of a head holder to which a face mask is fixed so as to immobilize the patient. Position errors due to the algorithms were obtained by evaluating the stereotactic coordinates of five sources detectable in each modality. Results: SPECT and MR position errors due to the algorithms were evaluated with respect to CT: Δx was ≤ 0.9 mm for MR and ≤ 1.4 mm for SPECT, Δy was ≤ 1 mm and ≤ 3 mm for MR and SPECT, respectively. Maximal differences in distance between estimated and actual fiducial centers (geometric mismatch) were in the order of the pixel size (0.8 mm for CT, 1.4 mm for MR, and 1.8 mm for SPECT). In an attempt to distinguish necrosis from residual disease, the image fusion protocol was studied in 35 primary or metastatic brain tumor patients. Conclusions: The image fusion technique has a good degree of accuracy as well as the potential to improve the specificity of tissue identification and the precision of the subsequent treatment planning

  10. Correlative neuroanatomy of computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Groot, J.

    1984-01-01

    Since the development of computed tomography (CT) more than a decade ago, still another form of imaging has become available that provides displays of normal and abnormal human structures. Magnetic resonance imaging is given complete coverage in this book. It describes both CT and MR anatomy that explains basic principles and the current status of imaging the brain and spine. The author uses three-dimensional concepts to provide the reader with a simple means to compare the main structures of the brain, skull and spine. Combining normal, gross neuroanatomic illustrations with CT and MR images of normal and abnormal conditions, the book provides diagnostic guidance. Drawings, photographs and radiologic images are used to help

  11. Parametric Response Mapping as an Indicator of Bronchiolitis Obliterans Syndrome after Hematopoietic Stem Cell Transplantation

    NARCIS (Netherlands)

    Galban, Craig J.; Boes, Jennifer L.; Bule, Maria; Kitko, Carrie L.; Couriel, Daniel R.; Johnson, Timothy D.; Lama, Vihba; Telenga, Eef D.; van den Berge, Maarten; Rehemtulla, Alnawaz; Kazerooni, Ella A.; Ponkowski, Michael J.; Ross, Brian D.; Yanik, Gregory A.

    2014-01-01

    The management of bronchiolitis obliterans syndrome (BOS) after hematopoietic cell transplantation presents many challenges, both diagnostically and therapeutically. We developed a computed tomography (CT) voxel-wise methodology termed parametric response mapping (PRM) that quantifies normal

  12. MRI screening before stem cell transplantation - necessary?; MRT-Untersuchung des Neurokraniums vor Stammzelltransplantation - notwendig oder ueberfluessig?

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, U.; Mentzel, H.J.; Kaiser, W.A. [Inst. fuer Diagnostische u. Interventionelle Radiologie, Friedr.-Schiller-Univ. Jena (Germany); Wolf, J.; Fuchs, D.; Gruhn, B. [Kinderklinik, Georgius-Agricola-Krankenhaus, Zeitz (Germany); Zintl, F. [Klinik fuer Kinder- und Jugendmedizin, Friedr.-Schiller-Univ. Jena (Germany)

    2008-01-15

    Purpose: in the context of stem cell transplantation (SCT), we often observe neurological complications as a consequence of immune system suppression, conditioning therapy or prophylaxis and treatment of graft-versus-host disease. Furthermore, cerebral lesions in existence prior to transplantation can be found. The aim of this study was to evaluate the benefit of cerebral magnetic resonance imaging (MRI) prior to stem cell transplantation. Patients and method: cerebral MR examinations of 116 children and adolescents were performed before SCT. Patients ranged in age from 1.1 to 21.4 years (mean 12.6 years). All MR images were obtained by a 1.5 T System. The predefined short protocol included an axial T1-weighted SE sequence and a coronary T2-weighted TSE sequence. We evaluated existing cerebral lesions, the diameter of the ventricular system, and the paranasal sinuses. In the case of pathological findings, the short examination protocol was expanded. Results: in 5 of 116 children (4.3%) we observed prior to SCT findings requiring immediate treatment although the patients did not show any clinical symptoms (1 x aspergilloma, 1 x hemorrhage of vascular anomaly). An increased risk of bleeding caused by cavernoma or another vascular anomaly without hemorrhage also had to be taken into account. 32 of 116 patients (37.1%) showed atrophic lesions. In 42 children (36.2%), we observed affections of the paranasal sinuses. (orig.)

  13. Cerebral fat embolism: Use of MR spectroscopy for accurate diagnosis

    Directory of Open Access Journals (Sweden)

    Laxmi Kokatnur

    2015-01-01

    Full Text Available Cerebral fat embolism (CFE is an uncommon but serious complication following orthopedic procedures. It usually presents with altered mental status, and can be a part of fat embolism syndrome (FES if associated with cutaneous and respiratory manifestations. Because of the presence of other common factors affecting the mental status, particularly in the postoperative period, the diagnosis of CFE can be challenging. Magnetic resonance imaging (MRI of brain typically shows multiple lesions distributed predominantly in the subcortical region, which appear as hyperintense lesions on T2 and diffusion weighted images. Although the location offers a clue, the MRI findings are not specific for CFE. Watershed infarcts, hypoxic encephalopathy, disseminated infections, demyelinating disorders, diffuse axonal injury can also show similar changes on MRI of brain. The presence of fat in these hyperintense lesions, identified by MR spectroscopy as raised lipid peaks will help in accurate diagnosis of CFE. Normal brain tissue or conditions producing similar MRI changes will not show any lipid peak on MR spectroscopy. We present a case of CFE initially misdiagnosed as brain stem stroke based on clinical presentation and cranial computed tomography (CT scan, and later, MR spectroscopy elucidated the accurate diagnosis.

  14. Lars von Triers film

    DEFF Research Database (Denmark)

    Nielsen, Lisbeth Overgaard

    2007-01-01

    Afhandlingen undersøger Lars von Triers filmæstetik, som den kommer til udtryk i spillefilmene fra perioden 1984-2007. Afhandlingen analyserer de enkelte films stil, virkningsstrategi og betydningsdannelse.......Afhandlingen undersøger Lars von Triers filmæstetik, som den kommer til udtryk i spillefilmene fra perioden 1984-2007. Afhandlingen analyserer de enkelte films stil, virkningsstrategi og betydningsdannelse....

  15. Comparison of CE-FDG-PET/CT with CE-FDG-PET/MR in the evaluation of osseous metastases in breast cancer patients

    OpenAIRE

    Catalano, O A; Nicolai, E; Rosen, B R; Luongo, A; Catalano, M; Iannace, C; Guimaraes, A; Vangel, M G; Mahmood, U; Soricelli, A; Salvatore, M

    2015-01-01

    Background: Despite improvements in treatments, metastatic breast cancer remains difficult to cure. Bones constitute the most common site of first-time recurrence, occurring in 40?75% of cases. Therefore, evaluation for possible osseous metastases is crucial. Technetium 99 (99Tc) bone scintigraphy and fluorodexossyglucose (FDG) positron emission tomography (PET)-computed tomography (PET-CT) are the most commonly used techniques to assess osseous metastasis. PET magnetic resonance (PET-MR) ima...

  16. [Sirolimus associated pneumonitis in a hematopoietic stem cell transplant patient].

    Science.gov (United States)

    García, Estefanía; Buenasmañanas, Diana; Martín, Carmen; Rojas, Rafael

    2015-07-06

    Sirolimus (SR) is a lipophilic macrocytic lactone with immunosuppressive properties (mTOR inhibitor) commonly used in solid organ transplantation and recently introduced in the prophylaxis and treatment of graft-versus-host disease. Its numerous side effects include: hyperlipidemia, arthralgias, noncardiac peripheral edema, thrombotic microangiopathy and interstitial pneumonitis. SR-associated pneumonitis is a rare but potentially serious complication due to its increasing utilization in transplant patients. We report the case of a patient undergoing hematopoietic stem cell transplantation with severe respiratory distress and SR therapy. Microbiological tests were all negative and other complications related to transplantation were discarded. The chest computed tomography of high-resolution showed pneumonitis. The SR therapy was interrupted and treatment was started with steroids with resolution of symptoms. SR associated pneumonitis is a potentially fatal side effect. In patients treated with SR and respiratory failure, we must suspect this complication because early recognition along with drug discontinuation and steroid treatment is essential to reverse this complication. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  17. PROGNOSTIC SIGNIFICANCE OF POSITRON EMISSION TOMOGRAPHY IN AUTOLOGOUS STEM CELL TRANSPLANTATION FOR NON-HODGKIN’S LYMPHOMA

    Directory of Open Access Journals (Sweden)

    V. G. Potapenko

    2016-01-01

    Full Text Available Objective: evaluation and comparison of positron emission tomography (PET prognostic value with other predictors of effectiveness in patients with non-Hodgkin’s lymphoma (NHL receiving high-dose chemotherapy with autologous hematopoietic stem cell transplantation (AHSCT.Materials and methods. The retrospective data on 49 consecutive patients with NHL  receiving high-dose chemotherapy with АHSCT was               analyzed. The median age was 36.2 (7–60  years. Median follow-up is currently 24 (1–82  months. Prognostic factors analyzed included sex, response to the initial chemotherapy, time to relapse, second-line chemotherapy regimen type, B-symptoms on relapse, serum lactate dehydrogenase and albumin levels, response assessed by computer tomography (CT, number of chemotherapy lines, condition regimen, PET-scan results before (PET1, n = 49 and after (PET2, n = 39 AHSCT.Results. Two-year overall and event-free survivals were 74.4 and 79.1 %, respectively. Patients with CT-confirmed progression prior to AH-SCT had the worse prognosis. Prognostic significance of PET-status  was shown in chemosensitive patients (partial/complete response.The overall survival in PET1-negative and PET1-positive patients were 95.4 vs 71.0 % (р = 0.019, respectively. In PET2-positive and PET2-negative patients the overall and event-free survivals were 59.8 vs 100 % (р = 0.001 and 54.4 vs 94.4 % (р = 0.02, respectively.     In combined analysis of PET1 and PET2 statuses prognostic significance of PET2 prevailed over PET1 results significance. The multivariate analysis confirmed only PET1 significance for survival prediction.   Conclusion. Chemosensitivity of the tumor, assessed by CT, is the most important prognostic factor. In chemosensitive patients achievement PET1 or PET2 negativity means better prognosis. The patients with PET positivity prior and after AHSCT have the worst prognosis.

  18. Radiation Exposure from Diagnostic Imaging in a Cohort of Pediatric Transplant Recipients.

    Directory of Open Access Journals (Sweden)

    Alexandra Seal

    Full Text Available Recipients of solid organ transplants (SOT have extensive diagnostic imaging (DI. The purpose of this study was to quantify this exposure. Children from northern Alberta with SOTs at Stollery Children's Hospital, Edmonton, Alberta January 1, 2006, to July 31, 2012, were included. Effective doses of radiation were estimated using published norms for DI performed post-transplant up to October 16, 2014. The 54 eligible children had 6215 DI studies (5628 plain films, 293 computerized tomography (CT scans, 149 positron emission topography (PET -CT scans, 47 nuclear medicine scans and 98 cardiac catheterizations. Children less than 5 years of age underwent more DI studies than did older children (median (IQR 140 (66-210 vs 49 (19-105, p = 0.010. Children with post-transplant lymphoproliferative disorder (N = 8 had more CT scans (median (IQR 13 (5.5-36 vs 1 (0-5, p100 mSv. In conclusion, a significant proportion of pediatric transplant recipients have sufficient radiation exposure post-transplant for DI to be at potential risk for radiation-induced malignancies.

  19. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  20. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  1. MR-fluid yield surface determination in disc-type MR rotary brakes

    International Nuclear Information System (INIS)

    Farjoud, Alireza; Vahdati, Nader; Fah, Yap Fook

    2008-01-01

    Magneto-rheological (MR) fluids are currently attracting a great deal of attention because of their unique rheological behavior. Many devices have been designed using MR fluids, and of potential interest here are disc-type MR rotary brakes. The plug flow region in MR devices is defined as the region where the fluid is not flowing. The plug flow region plays an important role in design and analysis of MR devices. In MR dampers, the damping coefficient is a function of the plug thickness. In MR valves, the plug thickness is used to control the flow rate through, and the pressure drop across, the MR valve. A MR clutch is performing at the highest efficiency when the entire MR gap is the plug region. For an MR rotary brake, the highest restraining torque is obtained when the entire gap is the plug region as far as there are no wall slip effects. In this paper, using the Bercovier and Engelman constitutive model, the MR fluid flow in disc-type MR brakes is modeled to determine the plug flow region. The resulting system of equations is solved numerically. It is shown that the existence of a plug flow region in the brake will affect the control torque ratio. Better estimation of the plug flow region results in better estimation of the viscous torque

  2. Dr. von Braun Briefing Walt Disney

    Science.gov (United States)

    1965-01-01

    Dr. von Braun began his association with Walt Disney in the 1950s when the rocket scientist appeared in three Disney television productions related to the exploration of space. Years later, Dr. von Braun invited Disney and his associates to tour the Marshall Space Flight Center (MSFC) in Huntsville, Alabama. This photograph is dated April 13, 1965. From left are R.J. Schwinghamer from the MSFC, Disney, B.J. Bernight, and Dr. von Braun.

  3. Computed tomography of complications of lung transplantation

    International Nuclear Information System (INIS)

    Soyer, P.; Devine, N.; Frachon, I.; Vinatier, I.; Stern, M.; Le Normand, S.; Scherrer, A.

    1997-01-01

    In spite of improvements in single or double lung transplantation (LT) technique, complications after LT are not uncommon; the most frequent ale anastomotic complications, infections and rejection (acute or chronic). Early detection of complications of LT allows the optimal therapeutic option to be taken, yielding decreased morbidity and mortality. In some cases, CT plays a key role in early detection of several complications of LT that may not be depicted with other diagnostic modalities, so that knowledge of their CT features is important. In this pictorial review, the authors describe the spectrum of CT features of the complications of LT (including reimplantation response, mechanical problems, acute and chronic rejection, infection, lymphoproliferative disorders, recurrence of the initial disease and complications involving the pleura and the anastomotic sites). In addition, the authors analyze the value of CT compared to that of the other available modalities for the detection of complications of LT. (orig.). With 19 figs

  4. Alpha-fetoprotein and (18)F-FDG positron emission tomography predict tumor recurrence better than Milan criteria in living donor liver transplantation.

    Science.gov (United States)

    Hong, Geun; Suh, Kyung-Suk; Suh, Suk-Won; Yoo, Tae; Kim, Hyeyoung; Park, Min-Su; Choi, YoungRok; Paeng, Jin Chul; Yi, Nam-Joon; Lee, Kwang-Woong

    2016-04-01

    Given the organ shortage for liver transplantation (LT) and the limitations of the current morphology-based selection criteria, improved criteria are needed to achieve the maximum benefit of LT for hepatocellular carcinoma (HCC). We hypothesized that a combination of biological markers may better predict the prognosis than the Milan criteria. HCC patients (n=123) with preoperative data on serum alpha-fetoprotein (AFP) levels and (18)F-fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) positivity underwent live-donor LT between January 2003 and December 2009. The cut-off values for serum AFP levels (200 ng/ml) and (18)F-FDG PET positivity (1.10) for tumor recurrence were determined by c-statistics using receiver operating characteristic curves. Univariate and multivariate analyses with preoperative variables were performed to find pre-transplant prognostic factors. Disease-free survival rates and overall survival rates were analysed with regard to serum AFP levels and (18)F-FDG PET positivity. The 5-year disease-free survival rates and overall survival rates were 80.3% and 81.6% respectively. (18)F-FDG PET positivity (hazard ratio (HR) 9.766, 95% CI 3.557-26.816; p<0.001) and serum AFP level (HR 6.234, 95% CI 2.643-14.707; p<0.001) were the only significant pre-transplant prognostic factors in the multivariate analysis; tumor number and size were not significant. A combination of criteria showed that the biologically high-risk group (AFP level ⩾200 ng/ml and PET-positive) had an HR of 29.069 (95% CI 8.797-96.053; p<0.001) compared with the double-negative group. Use of the Milan criteria yielded an HR of 1.351 (95% CI 0.500-3.652; p=0.553). The combination of the serum AFP level and (18)F-FDG PET data predicted better outcomes than those using the Milan criteria, improving objectivity when adult-to-adult living donor LT is contemplated. Copyright © 2015 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  5. Usefulness of MR angiography in renal tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato (Osaka National Hospital (Japan))

    1992-11-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a MAGNETOM H-15 scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author).

  6. Usefulness of MR angiography in renal tumor

    International Nuclear Information System (INIS)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato

    1992-01-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a 'MAGNETOM H-15' scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author)

  7. The impact of gender mismatching on early and late outcomes following heart transplantation

    Science.gov (United States)

    Lavee, Jacob; Arad, Michael; Shemesh, Yedida; Katz, Moshe; Kassif, Yigal; Asher, Elad; Elian, Dan; Har‐Zahav, Yedael; Goldenberg, Ilan; Freimark, Dov

    2016-01-01

    Abstract Aims The role of donor/recipient gender matching on the long‐term rejection process and clinical outcomes following heart transplantation (HT) outcomes is still controversial. We aim to investigate the impact of gender matching on early and long‐term outcome HT. Methods and results The study population comprised 166 patients who underwent HT between 1991 and 2013 and were prospectively followed up in a tertiary referral centre. Early and late outcomes were assessed by the type of donor–recipient gender match (primary analysis: female donor–male recipient [FD–MR, n = 36] vs. male donor–male recipient [MD–MR, n = 109]). Early mortality, need for inotropic support, length of hospital stay, and major perioperative adverse events did not differ between the FD–MR and MD–MR groups. However, the FD–MR group experienced significantly higher rates of early major rejections per patient as compared with the MD–MR group (1.2 ± 1.6 vs. 0.4 ± 0.8; P = 0.001), higher rates of overall major rejections (16 vs. 5.5 per 100 person years; P 2.5‐fold (P = 0.03) increase in the risk for rejections and with a >3‐fold (P = 0.01) increase in the risk for major adverse events during follow‐up. Conclusions Donor–recipient gender mismatch is a powerful independent predictor of early and late rejections and long‐term major adverse events following HT. PMID:28217310

  8. Tumor-mimicking primary angiitis of the central nervous system: initial and follow-up MR features

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youkyung; Kim, Ji-hoon; Kim, Eunhee; Yim, Yoo Jeong; Sohn, Chul-Ho [Department of Radiology, Seoul National University Hospital, Seoul (Korea); Park, Sung-Hye [Seoul National University, Department of Pathology, School of Medicine, Seoul (Korea); Chang, Kee-Hyun [Department of Radiology, Seoul National University Hospital, Seoul (Korea); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea); Seoul National University Medical Research Center, Neuroscience Research Institute, Seoul (Korea)

    2009-10-15

    Primary angiitis of the central nervous system (PACNS) is an extremely rare vasculitis of unknown etiology. The purpose of this study was to describe the initial and follow-up magnetic resonance (MR) imaging features of the tumor-mimicking PACNS. We retrospectively reviewed a total of 21 initial and follow-up brain MR images obtained in four patients with biopsy-proven PACNS mimicking brain tumor on MR images during the periods from 1 to 8.1 years. In the initial study, diffusion-weighted imaging (DWI; n=4), MR angiogram (n=4), conventional catheter angiogram (n=3), perfusion MR (n=1), and computed tomography (n=1) and proton MR spectroscopy (MRS; n=2) were included. The lesions of the brain were qualitatively assessed in terms of location, number, size, shape, signal intensity, absence or presence of hemorrhage, enhancement pattern, and changes on the follow-up studies. Initially, the lesion manifested as single suprasellar (n=1) and frontal hemispheric (n=1) mass and as multiple-enhancing lesions in the unilateral supratentorial hemisphere (n=2). A patient showed steno-occlusive lesions in the internal carotid and middle cerebral arteries. DWI, perfusion imaging, and MRS revealed inconsistent findings among the patients. On the follow-up studies, a patient had two relapses but there was either significant decrease in size and extent or disappearance of the lesions with immunosuppressive therapy in all patients. Tumor-mimicking PACNS shows variable features on initial MR images but shows good responses to appropriate immunosuppressive therapy on follow-up MR images. (orig.)

  9. Tumor-mimicking primary angiitis of the central nervous system: initial and follow-up MR features

    International Nuclear Information System (INIS)

    Lee, Youkyung; Kim, Ji-hoon; Kim, Eunhee; Yim, Yoo Jeong; Sohn, Chul-Ho; Park, Sung-Hye; Chang, Kee-Hyun

    2009-01-01

    Primary angiitis of the central nervous system (PACNS) is an extremely rare vasculitis of unknown etiology. The purpose of this study was to describe the initial and follow-up magnetic resonance (MR) imaging features of the tumor-mimicking PACNS. We retrospectively reviewed a total of 21 initial and follow-up brain MR images obtained in four patients with biopsy-proven PACNS mimicking brain tumor on MR images during the periods from 1 to 8.1 years. In the initial study, diffusion-weighted imaging (DWI; n=4), MR angiogram (n=4), conventional catheter angiogram (n=3), perfusion MR (n=1), and computed tomography (n=1) and proton MR spectroscopy (MRS; n=2) were included. The lesions of the brain were qualitatively assessed in terms of location, number, size, shape, signal intensity, absence or presence of hemorrhage, enhancement pattern, and changes on the follow-up studies. Initially, the lesion manifested as single suprasellar (n=1) and frontal hemispheric (n=1) mass and as multiple-enhancing lesions in the unilateral supratentorial hemisphere (n=2). A patient showed steno-occlusive lesions in the internal carotid and middle cerebral arteries. DWI, perfusion imaging, and MRS revealed inconsistent findings among the patients. On the follow-up studies, a patient had two relapses but there was either significant decrease in size and extent or disappearance of the lesions with immunosuppressive therapy in all patients. Tumor-mimicking PACNS shows variable features on initial MR images but shows good responses to appropriate immunosuppressive therapy on follow-up MR images. (orig.)

  10. Comparison of the performance of {sup 18}F-FP-CIT brain PET/MR and simultaneous PET/CT: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Sang Don; Chun, Kyung Ah [Dept. of Nuclear Medicine, Yeungnam University Hospital, Daegu (Korea, Republic of)

    2016-09-15

    {sup 18}F-FP-CIT [{sup 1'}8F-fluorinated N-3-fluoropropyl-2-beta-carboxymethoxy-3-beta-(4-iodophenyl) nortropane] has been well established and used for the differential diagnosis of atypical parkinsonian disorders. Recently, combined positron emission tomography (PET)/magnetic resonance (MR) was proposed as a viable alternative to PET/computed tomography (CT). The aim of this study was to compare the performances of conventional {sup 18}F-FP-CIT brain PET/CT and simultaneous PET/MR by visual inspection and quantitative analysis. Fifteen consecutive patients clinically suspected of having Parkinson's disease were recruited for the study.{sup 18}F-FP-CIT PET was performed during PET/CT and PET/MR. PET/CT image acquisition was started 90 min after intravenous injection of {sup 18}F-FP-CIT and then PET/MR images were acquired. Dopamine transporter (DAT) density in bilateral striatal subregions was assessed visually. Quantitative analyses were performed on bilateral striatal volumes of interest (VOIs) using average standardized uptake values (SUVmeans). Intraclass correlation coefficients (ICCs) and their 95 % confidence intervals (CIs) were assessed to compare PET/CT and PET/MR data. Bland-Altman plots were drawn to perform method-comparisons. All subjects showed a preferential decrease in DAT binding in the posterior putamen (PP), with relative sparing of the ventral putamen (VP). Bilateral striatal subregional binding ratio (BR) determined PET/CT and PET/MR demonstrated close interequipment correspondence (BRright caudate - ICC, 0.944; 95 % CI, 0.835-0.981, BRleft caudate - ICC, 0.917; 95 % CI, 0.753-0.972, BRright putamen - ICC, 0.976; 95 % CI, 0.929-0.992 and BRleft putamen - ICC, 0.970; 95 % CI, 0.911-0.990, respectively), and Bland-Altman plots showed interequipment agreement between the two modalities. It is known that MR provides more information about anatomical changes associated with brain diseases and to enable the anatomical allocations of

  11. Der Einfluß der Ablauforganisation auf die Effizienz von Entscheidungen: Eine empirische Untersuchung am Beispiel von Bilanzanalysen

    OpenAIRE

    Gemünden, Hans Georg

    1987-01-01

    Der vorliegende Beitrag widmet sich einem in der Organisationstheorie stark vernachlässigten Problem: der Ablauforganisation von Entscheidungen. Am Beispiel von Bilanzanalysen wird empirisch geprüft, in welcher Weise eine Gliederung des Prozesses nach Verrichtungen oder Objekten die Qualität der Analyse beeinflußt. Hierzu wird ein validiertes Konzept zur Messung der Qualität von Bilanzanalysen entwickelt. Es wird gezeigt, wie man mittels prozeßbegleitender experimenteller Organisationsforschu...

  12. Von Onlineplattformen und mittelalterlichen Märkten

    Directory of Open Access Journals (Sweden)

    Claudius Gräbner

    2017-12-01

    Full Text Available Mit der zunehmenden Digitalisierung und Vernetzung ökonomischer Systeme haben plattformbasierte Interaktionsbeziehungen stark an Bedeutung gewonnen. Hier werden zwei oder mehr Nutzungsgruppen durch eine dritte Seite, die Plattform, zusammengebracht. Die Interaktion wird in solchen zweiseitigen Märkten von den Plattformbetreibern kontrolliert. Kreditkartensysteme, Softwaremärkte oder werbefinanzierte Online-Communities stellen typische Beispiele dar. Da die Analyse von zweiseitigen Märkten mit Gleichgewichtsmodellen aufgrund der algebraischen Struktur des Problems in der Regel nicht praktikabel ist, präsentieren wir im vorliegenden Beitrag ein agentenbasiertes Modell, welches in einem kürzlich erschienenen Artikel ausführlicher diskutiert wird. Anhand von illustrativen Beispielen verdeutlichen wir die Implikationen eines agentenbasierten Ansatzes für die Innovationsökonomik im Allgemeinen und das Studium von Technologieentwicklung im Besonderen.

  13. Verbesserung der Symmetrie von Hirnaufnahmen entlang der Sagittalebene

    Science.gov (United States)

    Ens, Konstantin; Wenzel, Fabian; Fischer, Bernd

    Die lokale Symmetrie von Hirnscans entlang der Sagittalebene zu ermitteln und zu modizifieren, ist für eine Reihe neurologischer Anwendungen interessant. Beispielsweise kann der voxelweise Vergleich von rechter und linker Hirnhälfte nur dann Aufschluss über die Lokalisierung von Läsionen geben, wenn durch Transformation ein Hirnscan eine möglichst hohe Symmetrie aufweist. Ein weiteres Anwendungsgebiet ist die Visualisierung von medialen Hirnschnitten, für die die Trennfläche beider Hirnhälfte möglichst eben sein sollte. Diese Arbeit stellt die Entwicklung eines Verfahrens vor, mit dessen Hilfe die Symmetrie von Hirnaufnahmen entlang der Sagittalebene verbessert werden kann. Dies geschieht unter Verwendung von aktiven Konturen, die mit Hilfe einer neuartigen Kostenfunktion gesteuert werden. Experimente am Ende der Arbeit mit strukturellen Kernspinaufnahmen demonstrieren die Leistungsfähigkeit des Verfahrens.

  14. Synthesis and characterization of magneto-rheological (MR fluids for MR brake application

    Directory of Open Access Journals (Sweden)

    Bhau K. Kumbhar

    2015-09-01

    Full Text Available Magneto rheological (MR fluid technology has been proven for many industrial applications like shock absorbers, actuators, etc. MR fluid is a smart material whose rheological characteristics change rapidly and can be controlled easily in presence of an applied magnetic field. MR brake is a device to transmit torque by the shear stress of MR fluid. However, MR fluids exhibit yield stress of 50–90 kPa. In this research, an effort has been made to synthesize MR fluid sample/s which will typically meet the requirements of MR brake applications. In this study, various electrolytic and carbonyl iron powder based MR fluids have been synthesized by mixing grease as a stabilizer, oleic acid as an antifriction additive and gaur gum powder as a surface coating to reduce agglomeration of the MR fluid. MR fluid samples based on sunflower oil, which is bio-degradable, environmentally friendly and abundantly available have also been synthesized. These MR fluid samples are characterized for determination of magnetic, morphological and rheological properties. This study helps identify most suitable localized MR fluid meant for MR brake application.

  15. A new method of MR total spine imaging for showing the brace effect in scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz, A.; Kandyba, J.; Koenig, R.; Jaeger, U.E.; Gieseke, J.; Schmitt, O. [Univ. of Bonn (Germany)

    2001-07-01

    Bracing is a method of early, nonsurgical treatment for scoliosis, but a hypokyphotic effect on the thoracic spine is reported. We developed a magnetic resonance tomography (MR) procedure presenting an image of the whole spine in the coronal and sagittal planes (MR total spine imaging), and studied the brace effect, using this technique. We examined 26 female patients with idiopathic scoliosis treated with a Cheneau brace (mean age, 13.2 years; mean duration of brace treatment at the time of investigation, 1.5 years). The MR examinations were performed with the patient in the supine position with and without the brace in direct sequence. As measured on the coronal MR images, the thoracic curve was corrected, on average, from 29 deg to 22 deg (mean correction, 24%). There was a slight reduction in the sagittal Cobb angle measured between T4 and T12 (mean sagittal Cobb angle without brace, 14 deg ; with brace, 12 deg), which was still a significant change. MR total spine imaging could be a useful tool for studying the brace effect in scoliosis in two planes. Using this technique, we found reduced sagittal Cobb angles for the thoracic kyphosis with brace. Because there is no radiation exposure, the MR procedure has a potential use in the monitoring of brace treatment. (author)

  16. Magnetic resonance tomography - a possibility for noninvasive meniscus diagnosis. Pt. 1

    International Nuclear Information System (INIS)

    Wacker, F.; Koenig, H.; Sell, S.

    1989-01-01

    Meniscus tears were experimentally produced by surgery in 5 pigs. They were identified via MR tomography with the selected routine sequence (SE: TR 1600, TE 22/80msec, SD 3 mm) independent of position, orientation and severity. The best imaging was obtained between the 2nd and 8th weeks after the operation in the sagittal plane. Subsequently the contrast and with it simultaneously the delineation between intact fibrous cartilage and rupture cleft decreased; this could be observed in sequences weighted according to proton density and T2 in different degrees of intensity. Parallel to this a trial to induce degeneration in the meniscus tissue resulted 8 weeks after the operation in central, signal-intensive zones in the menisci. No success was achieved in trying to improve imaging of the pathological changes by means of intraarticular injections of Gd-DTPA; this was tried out at various points of time. Besides enabling the imaging of lesions of the fibrous cartilage as a matter of principle, MR tomography can also give limited information on the age of a meniscus tear. (orig.) [de

  17. Computed Tomography Findings of Human Polyomavirus BK (BKV)-Associated Cystitis in Allogeneic Hematopoietic Stem Cell Transplant Recipients

    International Nuclear Information System (INIS)

    Schulze, M.; Beck, R.; Igney, A.; Vogel, M.; Maksimovic, O.; Claussen, C.D.; Faul, C.; Horger, M.

    2008-01-01

    Background: Over 70% of the general population worldwide is positive for antibodies against polyomavirus hominis type 1 (BKV). Polyomavirus can be reactivated in immunocompromised patients and thereby induce urogenital tract infection, including cystitis. Purpose: To describe the computed tomography (CT) findings of human polyomavirus-induced cystitis in adult patients after allogeneic hematopoietic stem cell transplantation (allogeneic HCT). Material and Methods: The study population was a retrospective cohort of 11 consecutive adult patients (eight men, three women; age range 22-59 years, mean 42.9 years) who received allogeneic HCT between December 2003 and December 2007 and were tested positive for urinary BKV infection. All CT scans were evaluated with regard to bladder wall thickness, mucosal enhancement, distinct layering of thickened bladder wall, and presence of intravesical clots, perivesical stranding as well as attenuation values of intravesical urine. Clinical data concerning transplant and conditioning regimen variables and laboratory parameters were correlated with degree and extent of imaging findings. Results: All patients had clinical signs of cystitis with different degrees of thickening of the urinary bladder wall. Well-delineated urinary bladder layers were present in six patients. Thickening of the urinary bladder wall was continuous in nine of 11 patients. Increased attenuation of intravesical urine was found in seven patients with hemorrhagic cystitis. Four patients had intraluminal clots. Perivesical stranding was not a major CT finding, occurring in a mild fashion in three of 11 patients. The clinical classification of hemorrhagic cystitis did not correlate with the analyzed imaging parameters. Patient outcome was not influenced by this infectious complication. Conclusion: CT findings in patients with polyomavirus BK cystitis consist of different degrees of bladder wall thickening usually with good delineation of all mural layers and

  18. Computed Tomography Findings of Human Polyomavirus BK (BKV)-Associated Cystitis in Allogeneic Hematopoietic Stem Cell Transplant Recipients

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, M.; Beck, R.; Igney, A.; Vogel, M.; Maksimovic, O.; Claussen, C.D.; Faul, C.; Horger, M. [Dept. of Diagnostic Radiology, Dept. of Internal Medicine-Oncology, and Inst. of Medical Virology, Eberhard-Karls Univ., Tbingen (Germany)

    2008-12-15

    Background: Over 70% of the general population worldwide is positive for antibodies against polyomavirus hominis type 1 (BKV). Polyomavirus can be reactivated in immunocompromised patients and thereby induce urogenital tract infection, including cystitis. Purpose: To describe the computed tomography (CT) findings of human polyomavirus-induced cystitis in adult patients after allogeneic hematopoietic stem cell transplantation (allogeneic HCT). Material and Methods: The study population was a retrospective cohort of 11 consecutive adult patients (eight men, three women; age range 22-59 years, mean 42.9 years) who received allogeneic HCT between December 2003 and December 2007 and were tested positive for urinary BKV infection. All CT scans were evaluated with regard to bladder wall thickness, mucosal enhancement, distinct layering of thickened bladder wall, and presence of intravesical clots, perivesical stranding as well as attenuation values of intravesical urine. Clinical data concerning transplant and conditioning regimen variables and laboratory parameters were correlated with degree and extent of imaging findings. Results: All patients had clinical signs of cystitis with different degrees of thickening of the urinary bladder wall. Well-delineated urinary bladder layers were present in six patients. Thickening of the urinary bladder wall was continuous in nine of 11 patients. Increased attenuation of intravesical urine was found in seven patients with hemorrhagic cystitis. Four patients had intraluminal clots. Perivesical stranding was not a major CT finding, occurring in a mild fashion in three of 11 patients. The clinical classification of hemorrhagic cystitis did not correlate with the analyzed imaging parameters. Patient outcome was not influenced by this infectious complication. Conclusion: CT findings in patients with polyomavirus BK cystitis consist of different degrees of bladder wall thickening usually with good delineation of all mural layers and

  19. Computed Tomography Findings of Human Polyomavirus BK (BKV)-Associated Cystitis in Allogeneic Hematopoietic Stem Cell Transplant Recipients

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, M.; Beck, R.; Igney, A.; Vogel, M.; Maksimovic, O.; Claussen, C.D.; Faul, C.; Horger, M. (Dept. of Diagnostic Radiology, Dept. of Internal Medicine-Oncology, and Inst. of Medical Virology, Eberhard-Karls Univ., Tbingen (Germany))

    2008-12-15

    Background: Over 70% of the general population worldwide is positive for antibodies against polyomavirus hominis type 1 (BKV). Polyomavirus can be reactivated in immunocompromised patients and thereby induce urogenital tract infection, including cystitis. Purpose: To describe the computed tomography (CT) findings of human polyomavirus-induced cystitis in adult patients after allogeneic hematopoietic stem cell transplantation (allogeneic HCT). Material and Methods: The study population was a retrospective cohort of 11 consecutive adult patients (eight men, three women; age range 22-59 years, mean 42.9 years) who received allogeneic HCT between December 2003 and December 2007 and were tested positive for urinary BKV infection. All CT scans were evaluated with regard to bladder wall thickness, mucosal enhancement, distinct layering of thickened bladder wall, and presence of intravesical clots, perivesical stranding as well as attenuation values of intravesical urine. Clinical data concerning transplant and conditioning regimen variables and laboratory parameters were correlated with degree and extent of imaging findings. Results: All patients had clinical signs of cystitis with different degrees of thickening of the urinary bladder wall. Well-delineated urinary bladder layers were present in six patients. Thickening of the urinary bladder wall was continuous in nine of 11 patients. Increased attenuation of intravesical urine was found in seven patients with hemorrhagic cystitis. Four patients had intraluminal clots. Perivesical stranding was not a major CT finding, occurring in a mild fashion in three of 11 patients. The clinical classification of hemorrhagic cystitis did not correlate with the analyzed imaging parameters. Patient outcome was not influenced by this infectious complication. Conclusion: CT findings in patients with polyomavirus BK cystitis consist of different degrees of bladder wall thickening usually with good delineation of all mural layers and

  20. 3D and 4D magnetic susceptibility tomography based on complex MR images

    Science.gov (United States)

    Chen, Zikuan; Calhoun, Vince D

    2014-11-11

    Magnetic susceptibility is the physical property for T2*-weighted magnetic resonance imaging (T2*MRI). The invention relates to methods for reconstructing an internal distribution (3D map) of magnetic susceptibility values, .chi. (x,y,z), of an object, from 3D T2*MRI phase images, by using Computed Inverse Magnetic Resonance Imaging (CIMRI) tomography. The CIMRI technique solves the inverse problem of the 3D convolution by executing a 3D Total Variation (TV) regularized iterative convolution scheme, using a split Bregman iteration algorithm. The reconstruction of .chi. (x,y,z) can be designed for low-pass, band-pass, and high-pass features by using a convolution kernel that is modified from the standard dipole kernel. Multiple reconstructions can be implemented in parallel, and averaging the reconstructions can suppress noise. 4D dynamic magnetic susceptibility tomography can be implemented by reconstructing a 3D susceptibility volume from a 3D phase volume by performing 3D CIMRI magnetic susceptibility tomography at each snapshot time.

  1. Jacob Stael von Holstein ja palladionism eesti arhitektuuris / Ants Hein

    Index Scriptorium Estoniae

    Hein, Ants, 1952-

    2005-01-01

    Sõjaväeinsenerist ja arhitektist Jacob Stael von Holsteinist (1628, Pärnu-1679), tema kavandatud hoonetest ja rollist 17. sajandi II poole arhitektuuris. Fabian von Ferseni Toompeal Lossiplatsil asunud elamust (lammutati 1894) ja Maardu mõisahoonest, Hans von Ferseni Mäo mõisahoonest Järvamaal, Otto Wilhelm von Ferseni majast Toompeal, Axel von Roseni majast Tallinnas Pikk t. 28 (1670-74), Otto Reinhold von Taube majast Tartus (hävinud), J. S. von Holsteini enda hoonetest: majast Tallinnas Toompea 1, Anija mõisahoonest, elamust Riias jm. Bibliograafia lk. 452

  2. Transplant tourism and invasive fungal infection

    Directory of Open Access Journals (Sweden)

    I. Al Salmi

    2018-04-01

    Full Text Available Background: Deceased and live-related renal transplants (RTXs are approved procedures that are performed widely throughout the world. In certain regions, commercial RTX has become popular, driven by financial greed. Methods: This retrospective, descriptive study was performed at the Royal Hospital from 2013 to 2015. Data were collected from the national kidney transplant registry of Oman. All transplant cases retrieved were divided into two groups: live-related RTX performed in Oman and commercial-unrelated RTX performed abroad. These groups were then divided again into those with and without evidence of fungal infection, either in the wound or renal graft. Results: A total of 198 RTX patients were identified, of whom 162 (81.8% had undergone a commercial RTX that was done abroad. Invasive fungal infections (IFIs were diagnosed in 8% of patients who had undergone a commercial RTX; of these patients, 76.9% underwent a nephrectomy and 23.1% continued with a functioning graft. None of the patients with RTXs performed at the Royal Hospital contracted an IFI. The most common fungal isolates were Aspergillus species (including Aspergillus flavus, Aspergillus fumigatus, Aspergillus nidulans, and Aspergillus nigricans, followed by Zygomycetes. However, there was no evidence of fungal infection including Aspergillus outside the graft site. Computed tomography (CT findings showed infarction of the graft, renal artery thrombosis, aneurysmal dilatation of the external iliac artery, fungal ball, or just the presence of a perigraft collection. Of the total patients with IFIs, 23.1% died due to septic shock and 53.8% were alive and on hemodialysis. The remaining 23.1% who did not undergo nephrectomy demonstrated acceptable graft function. Conclusions: This is the largest single-center study on commercial RTX reporting the highest number of patients with IFI acquired over a relatively short period of time. Aspergillus spp were the main culprit fungi, with no

  3. MR imaging of ischemic penumbra

    International Nuclear Information System (INIS)

    Abe, Osamu; Aoki, Shigeki; Shirouzu, Ichiro; Kunimatsu, Akira; Hayashi, Naoto; Masumoto, Tomohiko; Mori, Harushi; Yamada, Haruyasu; Watanabe, Makoto; Masutani, Yoshitaka; Ohtomo, Kuni

    2003-01-01

    Cerebral ischemic stroke is one of the most fatal diseases despite current advances in medical science. Recent demonstration of efficacy using intravenous and intra-arterial thrombolysis demands therapeutic intervention tailored to the physiologic state of the individual tissue and stratification of patients according to the potential risks for therapies. In such an era, the role of the neuroimaging becomes increasingly important to evaluate the extent and location of tissues at risk of infarction (ischemic penumbra), to distinguish it from unsalvageable infarcted tissues or doomed hemorrhagic parenchyma. In this review, we present briefly the current role and limitation of computed tomography and conventional magnetic resonance imaging (MRI). We also present the possible applications of advanced MR techniques, such as diffusion and perfusion imaging, concentrating on the delineation or detection of ischemic penumbra

  4. Whole Body MR Imaging Versus 99mTC-Methylene Diphosphonate Scintigraphy in Detection of Skeletal Metastases

    International Nuclear Information System (INIS)

    SALEM, H.T.M.

    2009-01-01

    The introduction of new chemotherapy protocols, which include both marrow and stem cell transplantation, has increased the demand for accurate and early detection of skeletal metastases, particularly metastases to marrow (Eustace et al., 1997). All existing methods of detection skeletal metastases have limitations. Metastases to bone only become apparent on radiographs after the loss of more than 50% of the bone mineral content at the site of the disease. Although CT allows earlier detection of cortical destruction by imaging in contiguous tomographic slices, its ability to detect early deposits in marrow is limited (Gold et al., 1990). The use of bone scintigraphy in the assessment of skeletal abnormalities is based on increased sensitivity in detecting abnormalities before other diagnostic imaging techniques. The pitfall of bone scintigraphy is its lack of specificity. There must be close correlation of scintigraphic findings with those of other imaging modalities (Nadel et al., 2001). The high spatial resolution and excellent soft-tissue contrast make MR imaging an ideal tool for the detection of osseous lesions. The limited field of view must be considered a major limitation of conventional MR imaging. Furthermore MR imaging approaches were limited by long acquisition times. Development in MR imaging, such as the development of turbo sequences, have led to renewed interest in MR imaging as a potential whole body screening tool (Johnson et al., 1997 and Lauenstein et al., 2004).

  5. Shoulder instability syndrome: comparison of CT, arthrography and MR findings

    International Nuclear Information System (INIS)

    Ortiz, L.; Alcaraz, M.; Preciados, J.L.G.; Garcia Alvarez, A.; Castello, J.

    1995-01-01

    Currently, the two most reliable explorations for diagnosing the lesions that produce shoulder instability are computerized tomography with arthrography and magnetic resonance following intraarticular injection of gadolinium. Dynamic CT arthrography is considered the best method to assess these lesions; MR is a similar procedure but involves certain drawbacks, among them, its cost. The techniques applied in these explorations are reviewed, as are the anatomy of the different components of this joint and the radiological findings leading to a diagnosis of the pathology underlying its instability. (Author)

  6. A new NMR measuring instrument for logging while drilling; Ein neues Logging While Drilling Kernspinresonanz-Messgeraet

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, D.M.; Thern, H.F.; Kruspe, T.; Blanz, M. [Baker Hughes INTEQ GmbH, Celle (Germany); Strobel, J. [RWE Dea AG, Hamburg (Germany)

    2003-07-01

    Since 1990, commercial wireline MR measurements are carried out in boreholes. Logging while drilling is a comparatively new technique, in which a MR sensor is integrated in the drilling equipment so that the measured data are available more quickly. Problems may be caused by movement of the drilling rig. The resulting vibrations may distort the MR signal. Current development activities therefore focus on design optimization for higher vibration stability. The contribution explains vibration-induced wrong measuring signals and presents measures to reduce the effects of vibration. Further, a new LWD-MR measuring instrument is presented, the so-called MagTrak{sup TM} which combines the quality and advantages of cable MR-T{sub 2} measurements with a minimum of vibration effects, as is shown by MR data from a commercial borehole. [German] Seit 1990 werden Wireline-MR-Messungen kommerziell im Bohrloch durchgefuehrt. In den letzten Jahren wird an Messgeraeten gearbeitet, die bereits waehrend des Bohrens MR-Daten aufzeichnen (Logging While Drilling, LWD). Dazu wird ein MR-Sensor in den Bohrstrang integriert. Neben der schnelleren Verfuegbarkeit der MR-Daten besteht ein grosser Vorteil der LWD-MR-Messung darin, dass die Daten bereits kurz nach dem Bohren gemessen werden. Die Invasion von Bohrlochspuelung in die Formation dauert dann noch nicht lange an, und die MR-Messung findet im relativ unveraenderten Gestein statt. Probleme beim Einsatz von MR-Messgeraeten waehrend des Bohrens werden vor allem durch die Bewegungen des Bohrstranges verursacht. Vibrationen des MR-Sensors fuehren zu veraenderten Messbedingungen waehrend des Messvorgangs, was zu Verzerrungen im MR-Signal fuehren kann. Den Aufbau des Messgeraetes so zu optimieren, dass Vibrationen einen moeglichst kleinen Einfluss auf die Messung haben, ist ein aktuelles Ziel der heutigen LWD-MR-Entwicklung. In diesem Artikel werden vibrationsverursachte Signalfehler erklaert und Massnahmen genannt, die die

  7. MR imaging of gastric wall layers in vitro: correlation to the histologic wall structure; Experimentelle Darstellung der Schichten der Magenwand mittels MRT: Korrelation mit dem histologischen Wandaufbau

    Energy Technology Data Exchange (ETDEWEB)

    Lubienski, A.; Grenacher, L.; Schipp, A.; Duex, M. [Radiologische Klinik, Abt. Radiodiagnostik, Ruprecht-Karls-Univ. Heidelberg (Germany); Reith, W. [Abt. fuer Neuroradiologie der Radiologischen Universitaetsklinik, Univ. Saarland (Germany); Mechtersheimer, G. [Inst. fuer Allgemeine Pathologie, Ruprecht-Karls-Univ. Heidelberg (Germany)

    2002-04-01

    Purpose: To correlate gastric wall layers visible of MRI with the anatomical structure of the gastric wall. Methods: After macroscopic preparation 5 x 5 cm post-mortem tissue sections of the gastric antrum were evaluated using a 2.4 Tesla MR unit (Bruker, Ettlingen, Germany). MR imaging consisted of T2-weighted multi-spinecho sequences in longitudinal and axial directions. The specimens then were stained with hematoxylin-eosin for histological examination. After that histological correlation of the gastric wall layers visible on MRI was performed. Results: In all specimens four gastric wall layers could be clearly identified on MRI. The direct comparison of those layers to the histological findings showed the following correlation: 1. intermediate signal = mucosa, 2. hypointense signal = lamina muscularis mucosae, 3. hyperintense signal = submucosa, 4. intermediate signal = muscularis propria. Conclusions: Gastric wall layers visible on MRI were successfully correlated to the anatomic layers of the gastric wall. This allows us for the first time to classify invasion of gastric carcinoma using high spatial-resolution MR imaging. However, the subserosa and serosa are excluded from this conclusion, because so far a reliable statement concerning the value of MRI to depict these very variable layers is not possible. (orig.) [German] Ziel: Ziel der Studie war es, magnetresonanztomographisch sichtbare Schichten der Magenwand mit dem anatomischen Wandaufbau des Magens zu korrelieren. Methoden: Nach makroskopischer Skelettierung wurden 5 x 5 cm messende Stuecke des Magenantrums von fuenf Leichenmaegen in einem 2.4 Tesla MR-Geraet (Bruker, Ettlingen, Deutschland) untersucht. Es wurden T2-gewichtete Multispinechosequenzen in longitudinaler und axialer Richtung zum Praeparat angefertigt. Nach Faerbung der Magenpraeparate mit Haematoxylin-Eosin wurden die MR-Bilder mit den histologischen Schnitten in Bezug auf sichtbare Wandschichten korreliert. Ergebnisse: Regelmaessig konnten

  8. Dynamic MRI of ferumoxide-labeled bone mesenchmal stem cells after transplantation in infarcted myocardium

    International Nuclear Information System (INIS)

    Liu Qiong; Zhao Shihua; Lu Minjie; Jiang Shiliang; Yan Chaowu; Zhang Yan; Meng Liang; Tang Yue; Meng Xianmin; Wei Yingjie; Wang Qingzhi

    2009-01-01

    Objective: To investigate the ability of magnetic resonance imaging (MRI) in tracking magnetically labeled mesenchymal stem cells (MR-MSCs) in a swine myocardial infarction (MI) model. Methods: Adult Chinese mini-pigs (n=6) were subjected to open-chest experimental MI operation. Their autogeneic bone marrow-derived mesenchymal stem cells (MSCs) was cultured and doubly labeled with ferumoxides and DAPI. On the 14 th day after MSCs transplantation, the size and location of the myocardial infarction were assessed by using delayed-enhancement MRI (DE-MRI). Then the labeled MSCs were injected intramyocardially into peri-infarct zone and normal myocardium. At 24 hrs and 3 weeks after injection, the contrast and the volume of the MR-MSCs hypointense lesion from the MR images were acquired, and the contrast was determined using the difference in signal intensity between the hypointense and normal myocardium divided by signal intensity of the normal region. After humane euthanasia, the heart was excised and histology corresponding to MRI slices that demonstrated MR-MSCs lesions was performed. Repeated-measures ANOVA and a paired t test were used for comparison of the contrast and the volume of the MR-MSCs hypointense lesion at different time points. Comparisons between independent groups were performed with the standard Student t test. Results: The labeling efficiency of ferumoxides and DAPI was 100%. On the 14 th day after the MI operation, the average percentage of infracted myocardial area was (33.6±8.9)%. Twenty- four hours after MSCs transplantation, MSCs injection sites appeared as ovoid hypointensive lesions with sharp border on T 2 * images. At 24 h after injection, the signal contrast [(67.00±5.48)% vs (61.92±7.76)%,t=1.65, P=0.1158] and the size [(0.56±0.24) cm 2 vs (0.52±0.25) cm 2 , t=0.39, P=0.7044] of the lesions showed no statistical difference between the peri-infarct zone and the normal myocardium. At 3 weeks after injection, the signal contrast

  9. Clinical and diagnostic value of preoperative MR mammography and FDG-PET in suspicious breast lesions

    International Nuclear Information System (INIS)

    Walter, C.; Scheidhauer, K.; Theissen, P.; Scharl, A.; Goering, U.J.; Kugel, H.; Krahe, T.; Pietrzyk, U.

    2003-01-01

    Dynamic enhanced magnetic resonance (MR) mammography and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) of the breast were directly compared preoperatively in suspicious breast lesions. Forty-two breast lesions in 40 patients were examined with a three-dimensional dynamic MR imaging series and FDG-PET. The MR and PET examinations were evaluated separately and the results were compared with the histological findings. The sensitivity and specificity of each method were calculated. The diagnostic value of both modalities as single diagnostic tool and in combination was investigated. Nineteen malignant and 23 benign breast lesions were proven histologically. Magnetic resonance mammography and FDG-PET showed a sensitivity of 89 and 63%, respectively. The specificity was 74 and 91%, respectively. The combination of both imaging methods decreased the not-required biopsies from 55 to 17%. Only one false-negative finding - a patient pre-treated with chemotherapy - was observed in both methods. The combination of MR mammography and FDG-PET can help to decrease biopsies of benign breast lesions. Because of their high cost, these modalities should only be used in problematic cases to either rule out or to demonstrate malignancy. The best diagnostic strategy is achieved using MR mammography first. If the diagnosis is still questionable, FDG-PET can be performed. (orig.)

  10. Equiripple Digital Filter in Quadrature Mirror Filter Banks for Nuclear Magnetic Tomography

    Czech Academy of Sciences Publication Activity Database

    Gescheidtová, E.; Kubásek, R.; Smékal, Z.; Bartušek, Karel

    2007-01-01

    Roč. 37, č. 1 (2007), s. 141-149 ISSN 1738-6438 R&D Projects: GA ČR(CZ) GA102/07/0389; GA ČR(CZ) GA102/07/1086 Institutional research plan: CEZ:AV0Z20650511 Keywords : wavelet transform * digital filter * MR tomography Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  11. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  12. Diagnosis of Alzheimer's disease using brain perfusion SPECT and MR imaging: which modality achieves better diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kubota, Takao; Ushijima, Yo; Yamada, Kei; Okuyama, Chio; Kizu, Osamu; Nishimura, Tsunehiko

    2005-01-01

    The purpose of this study was to compare the accuracy of MR imaging and brain perfusion single-photon emission tomography (SPECT) in diagnosing Alzheimer's disease (AD). The transaxial section display of brain perfusion SPECT, three-dimensional stereotactic surface projection (3D-SSP) SPECT image sets, thin-section MR imaging of the hippocampus and perfusion MR imaging were evaluated in 66 subjects comprising 35 AD patients and 31 subjects without AD. SPECT and MR imaging were visually interpreted by two experts and two novices, and the diagnostic ability of each modality was evaluated by receiver operating characteristic (ROC) analysis. In the experts' interpretations, there was no significant difference in the area under the ROC curve (A z ) between 3D-SSP and thin-section MR imaging, whereas the A z of transaxial SPECT display was significantly lower than that of 3D-SSP (3D-SSP: 0.97, thin-section MR imaging: 0.96, transaxial SPECT: 0.91), and the A z of perfusion MR imaging was lowest (0.63). The sensitivity and specificity of each modality were, respectively, 80.0% and 96.8% for 3D-SSP, 77.1% and 96.8% for thin-section MR imaging, 60.0% and 93.5% for transaxial SPECT display and 34.3% and 100% for perfusion MR imaging. In the novices' interpretations, the A z , sensitivity and specificity of 3D-SSP were superior to those of thin-section MR imaging. Thin-section hippocampal MR imaging and 3D-SSP image sets had potentially equivalent value for the diagnosis of AD, and they were superior to transaxial SPECT display and perfusion MR imaging. For avoidance of the effect of interpreters' experience on image evaluation, 3D-SSP appears to be optimal. (orig.)

  13. Pulmonary infections in the late period after allogeneic bone marrow transplantation: chest radiography versus computed tomography

    International Nuclear Information System (INIS)

    Schueller, Gerd; Matzek, Wolfgang; Kalhs, Peter; Schaefer-Prokop, Cornelia

    2005-01-01

    Purpose: To analyze the capabilities of chest roentgenogram (CXR) and computed tomography (CT) in the evaluation of pulmonary infectious disease in the late period (>100 days) after allogeneic bone marrow transplantation (BMT). Methods: Ninety-four matched CXR and CT examinations were performed for clinical suspicion of infectious lung disease. The time gap between CXR and CT was 48 h at maximum. The image pairs were correlated with the patients' clinical course and with the results of diagnostic bronchoalveolar lavage (BAL). An unremarkable clinical course over the subsequent seven days after imaging and/or negative microbiological culture served as the basis for excluding infectious lung disease. Positive microbiological culture and/or improvement of symptoms after antibiotic therapy were considered as evidence of infectious disease. Results: The correlation with the clinical course and/or BAL revealed a significantly higher sensitivity, negative predictive value, and accuracy for CT than for CXR (89% versus 58%, P < 0.0001; 78% versus 47%, P < 0.0001; 90% versus 68%, P < 0.0001, respectively). CT was significantly more diagnostic in BAL verified fungal and bacterial infections (P < 0.05). Conclusion: CT is significantly superior to CXR in the evaluation of infectious pulmonary disease in the late phase after BMT. Therefore, an unremarkable CXR should be followed by a CT scan to reliably detect or to accurately exclude early pulmonary infection in these patients

  14. A note on derivations of Murray–von Neumann algebras

    Science.gov (United States)

    Kadison, Richard V.; Liu, Zhe

    2014-01-01

    A Murray–von Neumann algebra is the algebra of operators affiliated with a finite von Neumann algebra. In this article, we first present a brief introduction to the theory of derivations of operator algebras from both the physical and mathematical points of view. We then describe our recent work on derivations of Murray–von Neumann algebras. We show that the “extended derivations” of a Murray–von Neumann algebra, those that map the associated finite von Neumann algebra into itself, are inner. In particular, we prove that the only derivation that maps a Murray–von Neumann algebra associated with a factor of type II1 into that factor is 0. Those results are extensions of Singer’s seminal result answering a question of Kaplansky, as applied to von Neumann algebras: The algebra may be noncommutative and may even contain unbounded elements. PMID:24469831

  15. A note on derivations of Murray-von Neumann algebras.

    Science.gov (United States)

    Kadison, Richard V; Liu, Zhe

    2014-02-11

    A Murray-von Neumann algebra is the algebra of operators affiliated with a finite von Neumann algebra. In this article, we first present a brief introduction to the theory of derivations of operator algebras from both the physical and mathematical points of view. We then describe our recent work on derivations of Murray-von Neumann algebras. We show that the "extended derivations" of a Murray-von Neumann algebra, those that map the associated finite von Neumann algebra into itself, are inner. In particular, we prove that the only derivation that maps a Murray-von Neumann algebra associated with a factor of type II1 into that factor is 0. Those results are extensions of Singer's seminal result answering a question of Kaplansky, as applied to von Neumann algebras: The algebra may be noncommutative and may even contain unbounded elements.

  16. Analyse der pharmazeutischen Versorgungssituation von Patienten mit Psoriasis-Arthritis auf Basis von Routinedaten der Gesetzlichen Krankenversicherung.

    Science.gov (United States)

    Sondermann, Wiebke; Ventzke, Julia; Matusiewicz, David; Körber, Andreas

    2018-03-01

    Die Psoriasis-Arthritis (PsA) gehört zu den chronisch entzündlichen Gelenkerkrankungen. Trotz zahlreicher versorgungswissenschaftlicher Studien in Deutschland liegen zur pharmazeutischen Versorgungssituation von PsA-Patienten bisher kaum aktuelle Ergebnisse vor. Mit Hilfe einer systematischen Literaturrecherche sowie anhand von Routinedaten der Allgemeinen Ortskrankenkasse (AOK) Rheinland/Hamburg wird ein aktueller Überblick über die pharmazeutische Versorgung von PsA-Patienten in Deutschland gegeben. Selektiert wurden Versicherte aus dem ambulanten und stationären Bereich, die im 1. und 2. Quartal des Jahres 2014 die gesicherte Abrechnungsdiagnose Psoriasis-Arthritis L40.5+ aufwiesen. Anschließend wurden auf Basis dieser "vorab definierten" Kohorte die Arzneimitteldaten für 5 Jahre (01.01.2010-31.12.2014) abgerufen. Es konnten insgesamt n  =  3205 Versicherte (45 % männlich, 55 % weiblich) der AOK Rheinland/Hamburg mit einer gesicherten PsA-Diagnose selektiert werden. Das Durchschnittsalter betrug 58,9 Jahre. 53,7 % der PsA-Patienten wurden mit systemischen PsA-relevanten Arzneimitteln versorgt. Nichtsteroidale Antirheumatika (NSAR) wurden am häufigsten verordnet, gefolgt von systemischen Glucocorticoiden. Von den selektierten PsA-Patienten, die eine Systemtherapie erhielten, wurden 72,1 % mittels einer Disease-modifying-antirheumatic-Drug (DMARD)-Monotherapie behandelt, gefolgt von der Kombinationstherapie aus DMARDs und Biologika (20,9 %). Die pharmakologische Therapie der PsA muss eine Gewährleistung zwischen adäquater Versorgung der PsA mit Verhinderung der Krankheitsprogression und ökonomischer Verantwortung darstellen. © 2018 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  17. The role of computed tomography in modern paediatric uroradiology

    International Nuclear Information System (INIS)

    Maudgil, D.D.; McHugh, K.

    2002-01-01

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study

  18. The role of computed tomography in modern paediatric uroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Maudgil, D.D.; McHugh, K. E-mail: kmchugh@gosh.nhs.uk

    2002-08-01

    Computed tomography (CT) has developed a well-recognised role within paediatric uroradiology, especially in imaging of trauma, malignancy (in particular Wilms' tumour), atypical infection, and congenital urogenital abnormalities. CT can also be used for problem solving in nephrolithiasis and renal transplant assessment. These applications are illustrated and discussed, with an emphasis on particular information that can be gained from the CT study.

  19. Functional magnetic resonance imaging in neuroradiology; Funktionelle Magnetresonanztomographie in der Neuroradiologie

    Energy Technology Data Exchange (ETDEWEB)

    Essig, M.; Schoenberg, S.O.; Schlemmer, H.P.; Metzner, R.; Kaick, G. van [Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie

    2000-10-01

    The assessment of cerebral functions has long been the domain of positron-emission tomography and single photon emission computed tomography. The use of rapid imaging sequences and contrast agents enables physiological and pathophysiological cerebral processes to be assessed and monitored by magnetic resonance imaging. Both T1- and T2*-weighted contrast-enhanced fast imaging sequences can be used to assess tissue perfusion, vascularity, and microcirculation by applying models developed in nuclear medicine. The diffusion of water molecules and hemodynamic aspects of the macrovasculature can also be monitored. Functional magnetic resonance (MR) imaging enables the visualization of neuronal function and activity, and MR spectroscopy makes possible the metabolic mapping of lesions and surrounding tissue. The advantages of MR techniques includes their low invasiveness, multiplanar imaging ability, and lack of radiation. This contribution discusses the clinical use of functional MR imaging methods and their role in neuroradiological diseases. Measuring perfusion and diffusion allows detailed insight into the pathophysiology of cerebral ischemia and is already being used routinely in acute ischemic stroke. Dynamic MR angiography enables the hemodynamic assessment of vascular malformations. In CNS neoplasms these imaging techniques can improve lesion characterization and the selecting, planning, and monitoring of therapy. Functional MR imaging techniques have also revolutionized the study of psychiatric illness; however, their clinical utility here is still limited. Initial results in patients with dementia and schizophrenia have provided insight into the pathophysiological changes of these diseases. (orig.) [German] Funktionelle Untersuchungen des Gehirns waren lange Zeit lediglich mit nuklearmedizinischen Methoden wie der Positronenemissionstomographie (PET) und der Single-Photonen-Emission-Computed-Tomography (SPECT) moeglich. Durch den Einsatz schneller

  20. Computed tomography findings of postoperative complications in lung transplantation Achados tomográficos nas complicações pós-operatórias do transplante pulmonar

    Directory of Open Access Journals (Sweden)

    Bruno Hochhegger

    2009-03-01

    Full Text Available Due to the increasing number and improved survival of lung transplant recipients, radiologists should be aware of the imaging features of the postoperative complications that can occur in such patients. The early treatment of complications is important for the long-term survival of lung transplant recipients. Frequently, HRCT plays a central role in the investigation of such complications. Early recognition of the signs of complications allows treatment to be initiated earlier, which improves survival. The aim of this pictorial review was to demonstrate the CT scan appearance of pulmonary complications such as reperfusion edema, acute rejection, infection, pulmonary thromboembolism, chronic rejection, bronchiolitis obliterans syndrome, cryptogenic organizing pneumonia, post-transplant lymphoproliferative disorder, bronchial dehiscence and bronchial stenosis.Com o número cada vez maior e uma melhor sobrevida dos pacientes submetidos ao transplante pulmonar, os radiologistas devem estar cientes das diversas possibilidades de complicações associadas ao transplante de pulmão. O tratamento precoce das complicações é importante para a sobrevida a longo prazo dos receptores de transplante pulmonar. Com frequência, a TCAR desempenha um papel central na investigação de tais complicações. O reconhecimento precoce dos sinais de complicações proporciona um tratamento rápido e melhora a sobrevida. O objetivo desta revisão pictórica foi proporcionar uma visão sobre as complicações mais prevalentes na TC, tais como edema de reperfusão, rejeição aguda, infecção, tromboembolismo pulmonar, rejeição crônica, síndrome da bronquiolite obliterante, pneumonia em organização criptogênica, doença linfoproliferativa pós-transplante, deiscência brônquica e estenose brônquica.

  1. Incidence of Internal Mammary Lymph Nodes with Silicone Breast Implants at MR Imaging after Oncoplastic Surgery.

    Science.gov (United States)

    Sutton, Elizabeth J; Watson, Elizabeth J; Gibbons, Girard; Goldman, Debra A; Moskowitz, Chaya S; Jochelson, Maxine S; Dershaw, D David; Morris, Elizabeth A

    2015-11-01

    To assess the incidence of benign and malignant internal mammary lymph nodes (IMLNs) at magnetic resonance (MR) imaging among women with a history of treated breast cancer and silicone implant reconstruction. The institutional review board approved this HIPAA-compliant retrospective study and waived informed consent. Women were identified who (a) had breast cancer, (b) underwent silicone implant oncoplastic surgery, and (c) underwent postoperative implant-protocol MR imaging with or without positron emission tomography (PET)/computed tomography (CT) between 2000 and 2013. The largest IMLNs were measured. A benign IMLN was pathologically proven or defined as showing 1 year of imaging stability and/or no clinical evidence of disease. Malignant IMLNs were pathologically proven. Incidence of IMLN and positive predictive value (PPV) were calculated on a per-patient level by using proportions and exact 95% confidence intervals (CIs). The Wilcoxon rank sum test was used to assess the difference in axis size. In total, 923 women with breast cancer and silicone implants were included (median age, 46 years; range, 22-89 years). The median time between reconstructive surgery and first MR imaging examination was 49 months (range, 5-513 months). Of the 923 women, 347 (37.6%) had IMLNs at MR imaging. Median short- and long-axis measurements were 0.40 cm (range, 0.20-1.70 cm) and 0.70 cm (range, 0.30-1.90 cm), respectively. Two hundred seven of 923 patients (22.4%) had adequate follow-up; only one of the 207 IMLNs was malignant, with a PPV of 0.005 (95% CI: 0.000, 0.027). Fifty-eight of 923 patients (6.3%) had undergone PET/CT; of these, 39 (67.2%) had IMLN at MR imaging. Twelve of the 58 patients (20.7%) with adequate follow-up had fluorine 18 fluorodeoxyglucose-avid IMLN, with a median standardized uptake value of 2.30 (range, 1.20-6.10). Only one of the 12 of the fluorodeoxyglucose-avid IMLNs was malignant, with a PPV of 0.083 (95% CI: 0.002, 0.385). IMLNs identified at

  2. Comparison of radiography, computed tomography and magnetic resonance imaging in the detection of sacroiliitis accompanying ankylosing spondylitis

    International Nuclear Information System (INIS)

    Yu, Wei; Feng Feng; Yang Hongzen; Jiang Ming; Dion, E.; Genant, H.K.

    1998-01-01

    Objective. To compare magnetic resonance (MR) imaging, computed tomography (CT), and radiography in the detection of sacroiliitis accompanying ankylosing spondylitis (AS). Design and subjects. Nine volunteers and 24 patients were recruited. Radiography, CT, and MR imaging were completed within a 1-week period in 24 patients with AS. In precontrast MR examination, spin-echo T1, fast spin-echo T2, and gradient echo with rephasing T2* images were obtained without fat saturation using a 0.3-T imager for all volunteers and patients. Postcontrast MR examination was performed using the same precontrast SE T1 sequence for patients with AS. Results and conclusions. MR imaging directly showed the normal cartilage in all 16 sacroiliac joints of the 8 volunteers. In the 24 patients with AS, cartilage abnormalities were observed in 42 sacroiliac joints. More diagnoses of sacroiliitis were made using MR and CT imaging than using radiography (P<0.001). Therefore, low-field-strength MR can be useful in detecting early sacroiliitis in patients with AS. MR imaging was able to reveal early cartilage changes and bone marrow edema, which could not be found by either CT or radiography. (orig.)

  3. Clinical Study on Patients with Renal-Cell Carcinoma Accompanied with Von Hippel Lindau Disease Treated with Radiofrequency Ablation

    OpenAIRE

    波越, 朋也; 島本, 力; 辛島, 尚; 亀井, 麻依子; 福原, 秀雄; 深田, 聡; 佐竹, 宏文; 蘆田, 真吾; 山崎, 一郎; 鎌田, 雅行; 井上, 啓史; 山西, 伴明; 小川, 恭弘; 伊藤, 悟志; 執印, 太郎

    2014-01-01

    We report 12 renal cell carcinomas in 6 patients with Von Hippel-Lindau (VHL) disease treated with radiofrequency ablation (RFA). The mean age of the patients was 46 (range 38-53) years (male : 4, female : 2). Computed tomography (CT)-guided transcutaneous RFA was performed under conscious sedation with local anesthetics. The mean size of the tumors was 2.4 (range 0.7-8.1) cm. Nine of the 12 tumors (75%) were locally well controlled. However, 3 tumors in 2 patients developed visceral metastas...

  4. Rezension von: Gabriele Dietze: Weiße Frauen in Bewegung. Genealogien und Konkurrenzen von Race- und Genderpolitiken. Bielefeld: transcript Verlag 2013.

    Directory of Open Access Journals (Sweden)

    Philipp Dorestal

    2014-03-01

    Full Text Available Gabriele Dietze zeichnet das Verhältnis der Kategorien Race und Gender innerhalb der US-amerikanischen Geschichte von der Mitte des 19. Jahrhunderts bis zur Präsidentschaftswahl von Barack Obama nach. Dabei demonstriert sie anhand von zentralen Figuren der weißen Frauenbewegung deren ambivalente Positionen, die oftmals für progressive Inhalte wie das Eintreten für Frauenrechte stehen, gleichzeitig aber dann Anliegen von African Americans nicht artikulieren oder gar zum Schweigen bringen. Ebenso zeigt Dietze mithilfe von Texten einiger schwarzer Autor_innen sowie anhand berühmter Gerichtsprozesse, dass schwarze Emanzipation nicht notwendigerweise mit feministischen Positionen einhergehen musste, sondern sich vielmehr eine Konkurrenzsituation zwischen Race und Gender entspann.

  5. MR-based source localization for MR-guided HDR brachytherapy

    Science.gov (United States)

    Beld, E.; Moerland, M. A.; Zijlstra, F.; Viergever, M. A.; Lagendijk, J. J. W.; Seevinck, P. R.

    2018-04-01

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  6. CT examination of segmental liver transplants from living donors. Anatomy and pathological findings

    International Nuclear Information System (INIS)

    Krupski, G.; Maas, R.; Rogiers, X.; Burdelski, M.; Broelsch, C.E.

    1994-01-01

    A lack of suitable pediatric donors and significantly better results than conventional transplantation have contributed to the steady increase in the number of segmental liver transplants from living donors throughout the world. This article describes the diagnostic impact of axial CT scans following transplantation in a retrospective evaluation of 18 CT examinations of 10 children with an average age of two years. Both spiral and conventional CT scans permit precise visualization of the postoperative anatomy of the upper abdomen that is more distinct than the images provided by ultrasonic scans. Thus, CT scans better facilitate detection of pathological findings. In 60% of the patients (67% of the examinations), the CT scan permitted a definite diagnosis; in the remaining cases, no morphological correlate to the clinical and laboratory findings was detected. In addition to traditional ultrasonic scanning, computed tomography represents a further noninvasive imaging technique for postoperative diagnostics following segmental liver transplants from living donors. (orig.) [de

  7. Neoadjuvant chemotherapy in breast cancer: prediction of pathologic response with PET/CT and dynamic contrast-enhanced MR imaging--prospective assessment.

    Science.gov (United States)

    Tateishi, Ukihide; Miyake, Mototaka; Nagaoka, Tomoaki; Terauchi, Takashi; Kubota, Kazunori; Kinoshita, Takayuki; Daisaki, Hiromitsu; Macapinlac, Homer A

    2012-04-01

    To clarify whether fluorine 18 ((18)F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging performed after two cycles of neoadjuvant chemotherapy (NAC) can be used to predict pathologic response in breast cancer. Institutional human research committee approval and written informed consent were obtained. Accuracy after two cycles of NAC for predicting pathologic complete response (pCR) was examined in 142 women (mean age, 57 years: range, 43-72 years) with histologically proved breast cancer between December 2005 and February 2009. Quantitative PET/CT and DCE MR imaging were performed at baseline and after two cycles of NAC. Parameters of PET/CT and of blood flow and microvascular permeability at DCE MR were compared with pathologic response. Patients were also evaluated after NAC by using Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 based on DCE MR measurements and European Organization for Research and Treatment of Cancer (EORTC) criteria and PET Response Criteria in Solid Tumors (PERCIST) 1.0 based on PET/CT measurements. Multiple logistic regression analyses were performed to examine continuous variables at PET/CT and DCE MR to predict pCR, and diagnostic accuracies were compared with the McNemar test. Significant decrease from baseline of all parameters at PET/CT and DCE MR was observed after NAC. Therapeutic response was obtained in 24 patients (17%) with pCR and 118 (83%) without pCR. Sensitivity, specificity, and accuracy to predict pCR were 45.5%, 85.5%, and 82.4%, respectively, with RECIST and 70.4%, 95.7%, and 90.8%, respectively, with EORTC and PERCIST. Multiple logistic regression revealed three significant independent predictors of pCR: percentage maximum standardized uptake value (%SUV(max)) (odds ratio [OR], 1.22; 95% confidence interval [CI]: 1.11, 1.34; P PET/CT is superior to DCE MR for the prediction of pCR (%SUV(max) [90.1%] vs %κ

  8. Wohnquartiersbeschreibung: ein Instrument zur Regionalisierung von Nachbarschaften

    OpenAIRE

    Hoffmeyer-Zlotnik, Jürgen H. P.

    2001-01-01

    'Ausgehend von der Annahme, daß soziale Differenzierung sich in räumlicher Differenzierung niederschlägt, bietet eine Beschreibung der Struktur des näheren Wohnumfeldes die Möglichkeit, das Wohnquartier als Handlungsraum und Sozialisationsinstanz zur Interpretation von Umfragedaten zu nutzen. Das vorliegende Instrumentarium erlaubt es, das Wohnquartier unabhängig von Zensusdaten über Merkmale, die in der eigenen Umfrage erhoben werden, zu charakterisieren.' (Autorenreferat) 'The general hy...

  9. Generation of structural MR images from amyloid PET: Application to MR-less quantification.

    Science.gov (United States)

    Choi, Hongyoon; Lee, Dong Soo

    2017-12-07

    Structural magnetic resonance (MR) images concomitantly acquired with PET images can provide crucial anatomical information for precise quantitative analysis. However, in the clinical setting, not all the subjects have corresponding MR. Here, we developed a model to generate structural MR images from amyloid PET using deep generative networks. We applied our model to quantification of cortical amyloid load without structural MR. Methods: We used florbetapir PET and structural MR data of Alzheimer's Disease Neuroimaging Initiative database. The generative network was trained to generate realistic structural MR images from florbetapir PET images. After the training, the model was applied to the quantification of cortical amyloid load. PET images were spatially normalized to the template space using the generated MR and then standardized uptake value ratio (SUVR) of the target regions was measured by predefined regions-of-interests. A real MR-based quantification was used as the gold standard to measure the accuracy of our approach. Other MR-less methods, a normal PET template-based, multi-atlas PET template-based and PET segmentation-based normalization/quantification methods, were also tested. We compared performance of quantification methods using generated MR with that of MR-based and MR-less quantification methods. Results: Generated MR images from florbetapir PET showed visually similar signal patterns to the real MR. The structural similarity index between real and generated MR was 0.91 ± 0.04. Mean absolute error of SUVR of cortical composite regions estimated by the generated MR-based method was 0.04±0.03, which was significantly smaller than other MR-less methods (0.29±0.12 for the normal PET-template, 0.12±0.07 for multiatlas PET-template and 0.08±0.06 for PET segmentation-based methods). Bland-Altman plots revealed that the generated MR-based SUVR quantification was the closest to the SUVR values estimated by the real MR-based method. Conclusion

  10. As in Real Estate, Location Is What Matters: A Case Report of Transplant Ureteral Obstruction Due to an Inguinal Hernia.

    Science.gov (United States)

    Bugeja, Ann; Clark, Edward G; Sood, Manish M; Ali, Sohrab N

    2018-01-01

    Kidney allograft dysfunction is common and often reversible but can lead to allograft loss if not promptly evaluated. Transplant ureteral obstruction in an inguinal hernia is a rare cause of allograft dysfunction, but early recognition may prevent allograft loss. We present a case of a man with acute kidney allograft dysfunction who received a deceased donor kidney transplant 6 years earlier for end-stage kidney disease secondary to polycystic kidney disease. Abdominal ultrasounds revealed hydronephrosis without full visualization of the transplant ureter. Abdominal computed tomography revealed moderate hydronephrosis of the transplant kidney due to obstructed herniation of the transplant ureter in a right inguinal hernia. A stent was inserted into the transplant ureter to prevent further allograft dysfunction and facilitate hernia repair. Transplant ureteral obstruction is a rare cause of acute kidney allograft dysfunction, and its detection can be challenging. The recognition of transplant ureteral obstruction is vital to timely management for preventing allograft loss.

  11. MR imaging of the prostate; MRT der Prostata

    Energy Technology Data Exchange (ETDEWEB)

    Asbach, P.; Haas, M.; Hamm, B. [Charite Campus Benjamin Franklin, Klinik fuer Radiologie, Berlin (Germany)

    2015-12-15

    Prostate cancer is the most common form of cancer in men in Germany; however, there is a distinct difference between incidence and mortality. The detection of prostate cancer is based on clinical and laboratory testing using serum prostate-specific antigen (PSA) levels and transrectal ultrasound with randomized biopsy. Multiparametric MR imaging of the prostate can provide valuable diagnostic information for detection of prostate cancer, especially after negative results of a biopsy prior to repeat biopsy. In addition the use of MR ultrasound fusion-guided biopsy has gained in diagnostic importance and has increased the prostate cancer detection rate. The prostate imaging reporting and data system (PI-RADS) classification has standardized the reporting of prostate MRI which has positively influenced the acceptance by urologists. (orig.) [German] Das Prostatakarzinom ist in Deutschland die haeufigste Krebserkrankung des Mannes, wobei ein deutlicher Unterschied zwischen Inzidenz und Mortalitaet besteht. Die Detektion des Prostatakarzinoms basiert auf klinischer und laborchemischer Untersuchung (prostataspezifisches-Antigen[PSA]-Wert) sowie der transrektalen Ultraschalluntersuchung mit randomisierter Biopsie. Die multiparametrische MR-Tomographie kann zur Detektion des Prostatakarzinoms, insbesondere bei negativer Biopsie vor einer erneuten Biopsie wertvolle diagnostische Informationen liefern. Zudem wird zunehmend die MRT-Ultraschall-Fusionsbiopsie in der Diagnostik eingesetzt, wodurch die Detektionsrate des Prostatakarzinoms deutlich gesteigert werden kann. Mit Einfuehrung der PI-RADS-Klassifikation (Prostate Imaging-Reporting and Data System) konnte zudem eine Standardisierung der Befundung erreicht werden, was die Akzeptanz der MRT der Prostata in der Urologie erhoeht hat. (orig.)

  12. Optimized sampling of hydroperoxides and investigations of the water vapour dependence of hydroperoxide formation during ozonolysis of alkenes; Optimierung der Probenahme von Hydroperoxiden und Untersuchungen zur Wasserdampfabhaengigkeit der Bildung von Hydroperoxiden bei der Ozonolyse von Alkenen

    Energy Technology Data Exchange (ETDEWEB)

    Becker, K.H.; Plagens, H.

    1997-06-01

    There are several sampling methods for hydroperoxides none of which is particularly reliable. The authors therefore tested three new methods in order to optimize hydroperoxide sampling and, using the optimized sampling procedure, to investigate the water vapour dependence of hydroperoxide formation during ozonolysis of alkenes. (orig.) [Deutsch] Fuer die Probenahme von Hydroperoxiden existieren verschiedene Verfahren, von denen bisher keines als besonders zuverlaessig angesehen werden konnte. Daher wurden in dieser Arbeit drei Verfahren getestet, um die Probenahme von Hydroperoxiden zu optimieren und mit dem entsprechenden Verfahren die Wasserdampfabhaengigkeit der Bildung von Hydroperoxiden bei der Ozonolyse von Alkenen zu untersuchen. (orig.)

  13. Mediastinal lymphoma: quantitative changes in gadolinium enhancement at MR imaging after treatment.

    Science.gov (United States)

    Rahmouni, A; Divine, M; Lepage, E; Jazaerli, N; Belhadj, K; Gaulard, P; Golli, M; Reyes, F; Vasile, N

    2001-06-01

    To compare changes in gadolinium enhancement at magnetic resonance (MR) imaging with outcome in mediastinal lymphoma after treatment. Thirty-one patients with bulky mediastinal lymphoma (17 with Hodgkin disease, 14 with non-Hodgkin lymphoma) underwent serial MR imaging before and up to 50 months after treatment, with routine follow-up (including computed tomography). Signal intensity ratios between masses and muscle were calculated on T1-weighted, T2-weighted, and contrast material-enhanced T1-weighted spin-echo MR images. The percentage enhancement and signal intensity ratios of mediastinal masses on T2-weighted MR images were calculated at diagnosis and during and after treatment. Twenty-one patients with persistent complete remission had a mean percentage enhancement of residual masses (4%; range, -26% to 40%) that was significantly lower than that of initial masses (78%; range, 41%-124%). Although the mean signal intensity ratio of residual masses on T2-weighted images was significantly lower than that of initial masses, an increase in this ratio was observed in four patients after treatment. In seven patients with relapse, the percentage enhancement value of the residual mass was as high as that of the initial mass. Gadolinium enhancement of lymphomatous masses of the mediastinum decreased markedly after treatment in patients in continuous complete remission but not in patients with relapse.

  14. Still's Disease in a Pediatric Patient after Liver Transplantation

    Directory of Open Access Journals (Sweden)

    Juan-Carlos Meza

    2013-01-01

    Full Text Available Still's disease (SD is a multisystemic inflammatory disease characterized by persistent arthritis and in many cases with fever of unknown origin. Diagnosis of SD is challenging because of nonspecific characteristics and especially in the case of a patient with solid organ transplantation and immunosuppressive therapy where multiple causes of fever are possible. There is no diagnostic test for SD, even though some useful diagnostic criteria or laboratory findings, such as serum ferritin levels, have been proposed, and useful imaging studies for the diagnosis or followup of SD have not been developed. We report the case of a 9-year-old child who presented with high grade fever associated with joint pain after a history of liver transplantation and immunosuppressive therapy. Laboratory tests showed increased acute phase reactants, elevated ferritin, and leukocytosis. An 18 F-fluorodeoxyglucose positron emission tomography (18F-FDG PET was performed identifying abnormal hypermetabolic areas localized in spleen, transplanted liver, and bone marrow secondary to inflammatory process. All infectious, autoimmune, and malignant causes were ruled out. A diagnosis of SD was performed and a steroid-based regimen was initiated with adequate response and no evidence of recurrence. To our knowledge this is the first case of SD following a solid organ transplant.

  15. MRI of the transplanted endothelial progenitor cells for prevent atherosclerotic plaque formation

    International Nuclear Information System (INIS)

    Ma Zhanlong; Teng Gaojun; Mai Xiaoli; Chen Jun; Sun Junhui; Zhang Hongying; Yu Hui; Li Guozhao

    2007-01-01

    Objective: To evaluate the 1.5 T magnetic resonance imaging system to depict and track in vivo of magnetically labeled endothelial progenitor cells (EPCs), and to study the possibility for preventing the atherosclerotic plaque formation in New Zealand rabbit model of carotid arterial injury after transplantation. Methods: New Zealand rabbit EPCs were isolated, confirmed, expanded and then incubated with home synthesized Fe 2 O 3 -PLL, Prussian blue stain was performed for showing intracellular irons. The model of carotid arterial injury was performed by 2.5F balloons, the group A of 8 rabbits received magnetically labeled EPCs, group B of 3 rabbits received fluorescent-labeled EPCs and the group C of 5 rabbits were given same volume saline injection after endothelial injury of the carotid artery. MR imaging and histology were performed and compared 4 days later for randomly chosen three rabbit, each from one of the three group; all the other rabbits were fed with high lipid diet and examed using MR imaging and histology after 15 weeks. Results: Epcs labeling efficiency was more than 95% by Prussian blue stain, 4 days after transplantation of EPCs, only in group A, the injured endothelium of carotid artery had signal intensity loss in T 2 * WI, which were correlated well with the area where the most Prussian blue staining positive cells were found in histopathology analyses. The rabbits of group A and B which received EPCs transplantation exhibited fewer plaques formation than those of the group C (P 2 O 3 -PLL. The 1.5 T magnetic resonance imaging system could depict and monitor the magnetically labeled endothelial progenitor cells homing to the injured endothelium of the artery, and EPCs contribute to preventing atherosclerotic plaque formation in New Zealand rabbit model of atherosclerosis. (authors)

  16. Homopteren von Java, gesammelt von Herrn Edw. Jacobson

    NARCIS (Netherlands)

    Melichar, L.

    1914-01-01

    Herr Edw. Jacobson hat auf Java in den Jahren 1908— 1910 Homopteren gesammelt und mir die Bearbeitung des gesammelten Materiales übertragen. Die Jacobson’sche Ausbeute ist insoferne bemerkenswert, als dieselbe viele Mikrohomopteren enthält, welche von nichtfachkundigen Sammlern gewöhnlich nicht

  17. Allergic fungal sinusitis: clinico-pathological aspects. Findings on CT and MR

    International Nuclear Information System (INIS)

    Romero, A.; Bueno, A.; Conde, M. A.; Trigo, J. E.

    1999-01-01

    Allergic fungal sinusitis (AFS) represents the most recently described form of chronic sinusitis caused by fungi. It occurs in affects teenagers and young adults with atopic antecedents. This disease is a non-invasive chronic sinusitis, fungus acts as the allergen, causing a host immune response, mediated by type I and III reactions. Typically, several paranasal sinuses are usually involved with unilateral predominance. Most common clinical findings are headache, different grades of nasal obstruction and proptosis. Diagnostic criteria have been proposed for this entity, including imaging findings obtained with computed tomography (CT). Computed tomography and magnetic resonance imaging findings together have recently been postulated as practically pathognomonic. Treatment and prognosis of this entity, different from other types of fungal sinusitis, makes important to achieve a correct diagnosis. On this task, imaging studies as CT and MR play an important role. (Author) 23 refs

  18. MR tractography

    International Nuclear Information System (INIS)

    Kinosada, Yasutomi; Okuda, Yasuyuki; Ono, Mototsugu

    1993-01-01

    We developed a new noninvasive technique to visualize the anatomical structure of the nerve fiber system in vivo, and named this technique magnetic resonance (MR) tractography and the acquired image an MR tractogram. MR tractography has two steps. One is to obtain diffusion-weighted images sensitized along axes appropriate for depicting the intended nerve fibers with anisotropic water diffusion MR imaging. The other is to extract the anatomical structure of the nerve fiber system from a series of diffusion-weighted images by the maximum intensity projection method. To examine the clinical usefulness of the proposed technique, many contiguous, thin (3 mm) coronal two-dimensional sections of the brain were acquired sequentially in normal volunteers and selected patients with paralyses, on a 1.5 Tesla MR system (Signa, GE) with an ECG-gated Stejskal-Tanner pulse sequence. The structure of the nerve fiber system of normal volunteers was almost the same as the anatomy. The tractograms of patients with paralyses clearly showed the degeneration of nerve fibers and were correlated with clinical symptoms. MR tractography showed great promise for the study of neuroanatomy and neuroradiology. (author)

  19. Incidental findings of the kidneys, adrenal glands, adnexa uteri, gastrointestinal tract, mesentery and lymph nodes. Assessment and management recommendations; Zufallsbefunde von Niere, Nebenniere, Adnexen, Gastrointestinaltrakt, Mesenterium und Lymphknoten. Bewertung und Managementempfehlung

    Energy Technology Data Exchange (ETDEWEB)

    Scharitzer, M.; Tamandl, D.; Ba-Ssalamah, A. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2017-04-15

    Besides the upper abdominal parenchymal organs, the increasing application of cross-sectional imaging has also led to a rising number of incidental findings in the kidneys, adrenal glands, adnexa uteri, the gastrointestinal tract, mesentery and abdominal lymph nodes. Abdominal computed tomography investigations often show unexpected findings without any correlating symptoms. The growing clinical relevance is due to the large number of incidental findings as well as an increasing awareness of ethical and socioeconomic factors. When interpreting radiological findings not only morphological criteria but also individual risk factors of the patient and the clinical context are of great importance. The aims of this article are the description and evaluation of frequent incidental findings detected by computed tomography and to provide information about management recommendations. (orig.) [German] Neben den parenchymatoesen Oberbauchorganen hat der zunehmende Einsatz von Schnittbildverfahren zu einer vermehrten Anzahl von Zufallsbefunden der Nieren, Nebennieren, Adnexe, des Gastrointestinaltrakts, Mesenteriums und der intraabdominellen Lymphknoten gefuehrt. Abdominelle CT-Untersuchungen zeigen haeufig unerwartete Befunde ohne korrelierende Symptomatik. Die steigende klinische Relevanz ist einerseits auf die Zunahme inzidenteller Pathologien und andererseits auf ein wachsendes Bewusstsein ethischer und soziooekonomischer Faktoren zurueckzufuehren. Bei der radiologischen Interpretation sind neben morphologischen Kriterien sowohl die Einbeziehung der individuellen Risikofaktoren des Patienten als auch der klinische Gesamtkontext von grosser Bedeutung. Das Ziel dieses Artikels ist eine Beschreibung und Bewertung der in der Computertomographie detektierten genannten Zufallsbefunde sowie weiterer Managementempfehlungen. (orig.)

  20. [Anja Wilhelmi. Lebensweltlen von Frauen der deutschen Oberschicht im Baltikum (1800-1939). Eine Untersuchung anhand von Autobiographien] / Alexander Ewig

    Index Scriptorium Estoniae

    Ewig, Alexander, 1980-

    2011-01-01

    Arvustus: Wilhelmi, Anja. Lebenswelten von Frauen der deutschen Oberschicht im Baltikum (1800-1939). Eine Untersuchung anhand von Autobiographien. (Veröffentlichungen des Nordost-Instituts, 10.) (Wiesbaden : HArrassowitz 2008)

  1. Using OCT to predict post-transplant renal function

    Science.gov (United States)

    Andrews, Peter M.; Chen, Yu; Wierwille, Jeremiah; Joh, Daniel; Alexandrov, Peter; Rogalsky, Derek; Moody, Patrick; Chen, Allen; Cooper, Matthew; Verbesey, Jennifer E.; Gong, Wei; Wang, Hsing-Wen

    2013-03-01

    The treatment of choice for patients with end-stage renal disease is kidney transplantation. However, acute tubular necrosis (ATN) induced by an ischemic insult (e.g., from prolonged ex vivo storage times, or non-heart beating cadavers) is a major factor limiting the availability of donor kidneys. In addition, ischemic induced ATN is a significant risk factor for eventual graft survival and can be difficult to discern from rejection. Currently, there are no rapid and reliable tests to determine ATN suffered by donor kidneys and whether or not donor kidneys might exhibit delayed graft function. OCT (optical coherence tomography) is a rapidly emerging imaging modality that can function as a type of "optical biopsy", providing cross-sectional images of tissue morphology in situ and in real-time. In a series of recent clinical trials, we evaluated the ability of OCT to image those features of the renal microstructure that are predictive of ATN. Specifically, we found that OCT could effectively image through the intact human renal capsule and determine the extent of acute tubular necrosis. We also found that Doppler based OCT (i.e., DOCT) revealed renal blood flow dynamics that is also reported to be a determiner of post-transplant renal function. This kind of information will allow transplant surgeons to make the most efficient use of available donor kidneys, eliminate the possible use of bad donor kidneys, provide a measure of expected post-transplant renal function, and allow better distinction between post-transplant immunological rejection and ischemic-induced acute renal failure.

  2. Craniocervical artery dissection: MR imaging and MR angiographic findings

    International Nuclear Information System (INIS)

    Oelerich, M.; Schuierer, G.; Stoegbauer, F.; Kurlemann, G.; Schul, C.

    1999-01-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.)

  3. Craniocervical artery dissection: MR imaging and MR angiographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Oelerich, M.; Schuierer, G. [Institute of Clinical Radiology, University of Muenster (Germany); Stoegbauer, F. [Department of Neurology, University of Muenster (Germany); Kurlemann, G. [Department of Pediatric Neurology, University of Muenster (Germany); Schul, C. [Department of Neurosurgery, University of Muenster (Germany)

    1999-09-01

    Dissection of the carotid and vertebral arteries is a not so uncommon cause of stroke and has to be considered as a differential diagnosis especially in younger patients. Therapeutic and prognostic implications are different from those in extracranial atherosclerotic disease. Dissection results from hemorrhage into the vessel wall usually between the layers of the media. Digital subtraction angiography (DSA) depicts the resulting luminal compromise that may reveal some typical, but not specific, findings. The same is true for non-invasive angiographic techniques such as time-of-flight magnetic resonance angiography (MRA) and computed tomography angiography (CTA), which have shown accurate results compared with DSA. The main advantage of these techniques is the direct visualization of the vessel wall confirming the intramural hematoma. This is achieved best with MR imaging due to the high signal of blood degradation products on T1- and T2-weighted images. Therefore, MRI in combination with MRA is presently the method of choice for initial diagnosis and follow-up of craniocervical artery dissection (CCAD). In some questionable cases, CTA is a non-invasive alternative that is independent of flow phenomena. (orig.) With 6 figs., 2 tabs., 33 refs.

  4. Macrophage depletion and Schwann cell transplantation reduce cyst size after rat contusive spinal cord injury.

    Science.gov (United States)

    Lee, Yee-Shuan; Funk, Lucy H; Lee, Jae K; Bunge, Mary Bartlett

    2018-04-01

    Schwann cell transplantation is a promising therapy for the treatment of spinal cord injury (SCI) and is currently in clinical trials. In our continuing efforts to improve Schwann cell transplantation strategies, we sought to determine the combined effects of Schwann cell transplantation with macrophage depletion. Since macrophages are major inflammatory contributors to the acute spinal cord injury, and are the major phagocytic cells, we hypothesized that transplanting Schwann cells after macrophage depletion will improve cell survival and integration with host tissue after SCI. To test this hypothesis, rat models of contusive SCI at thoracic level 8 were randomly subjected to macrophage depletion or not. In rat subjected to macrophage depletion, liposomes filled with clodronate were intraperitoneally injected at 1, 3, 6, 11, and 18 days post injury. Rats not subjected to macrophage depletion were intraperitoneally injected with liposomes filled with phosphate buffered saline. Schwann cells were transplanted 1 week post injury in all rats. Biotinylated dextran amine (BDA) was injected at thoracic level 5 to evalute axon regeneration. The Basso, Beattie, and Bresnahan locomotor test, Gridwalk test, and sensory test using von Frey filaments were performed to assess functional recovery. Immunohistochemistry was used to detect glial fibrillary acidic protein, neurofilament, and green fluorescent protein (GFP), and also to visulize BDA-labelled axons. The GFP labeled Schwann cell and cyst and lesion volumes were quantified using stained slides. The numbers of BDA-positive axons were also quantified. At 8 weeks after Schwann cell transplantation, there was a significant reduction in cyst and lesion volumes in the combined treatment group compared to Schwann cell transplantation alone. These changes were not associated, however, with improved Schwann cell survival, axon growth, or locomotor recovery. Although combining Schwann cell transplantation with macrophage

  5. Macrophage depletion and Schwann cell transplantation reduce cyst size after rat contusive spinal cord injury

    Science.gov (United States)

    Lee, Yee-Shuan; Funk, Lucy H.; Lee, Jae K.; Bunge, Mary Bartlett

    2018-01-01

    Schwann cell transplantation is a promising therapy for the treatment of spinal cord injury (SCI) and is currently in clinical trials. In our continuing efforts to improve Schwann cell transplantation strategies, we sought to determine the combined effects of Schwann cell transplantation with macrophage depletion. Since macrophages are major inflammatory contributors to the acute spinal cord injury, and are the major phagocytic cells, we hypothesized that transplanting Schwann cells after macrophage depletion will improve cell survival and integration with host tissue after SCI. To test this hypothesis, rat models of contusive SCI at thoracic level 8 were randomly subjected to macrophage depletion or not. In rat subjected to macrophage depletion, liposomes filled with clodronate were intraperitoneally injected at 1, 3, 6, 11, and 18 days post injury. Rats not subjected to macrophage depletion were intraperitoneally injected with liposomes filled with phosphate buffered saline. Schwann cells were transplanted 1 week post injury in all rats. Biotinylated dextran amine (BDA) was injected at thoracic level 5 to evalute axon regeneration. The Basso, Beattie, and Bresnahan locomotor test, Gridwalk test, and sensory test using von Frey filaments were performed to assess functional recovery. Immunohistochemistry was used to detect glial fibrillary acidic protein, neurofilament, and green fluorescent protein (GFP), and also to visulize BDA-labelled axons. The GFP labeled Schwann cell and cyst and lesion volumes were quantified using stained slides. The numbers of BDA-positive axons were also quantified. At 8 weeks after Schwann cell transplantation, there was a significant reduction in cyst and lesion volumes in the combined treatment group compared to Schwann cell transplantation alone. These changes were not associated, however, with improved Schwann cell survival, axon growth, or locomotor recovery. Although combining Schwann cell transplantation with macrophage

  6. Macrophage depletion and Schwann cell transplantation reduce cyst size after rat contusive spinal cord injury

    Directory of Open Access Journals (Sweden)

    Yee-Shuan Lee

    2018-01-01

    Full Text Available Schwann cell transplantation is a promising therapy for the treatment of spinal cord injury (SCI and is currently in clinical trials. In our continuing efforts to improve Schwann cell transplantation strategies, we sought to determine the combined effects of Schwann cell transplantation with macrophage depletion. Since macrophages are major inflammatory contributors to the acute spinal cord injury, and are the major phagocytic cells, we hypothesized that transplanting Schwann cells after macrophage depletion will improve cell survival and integration with host tissue after SCI. To test this hypothesis, rat models of contusive SCI at thoracic level 8 were randomly subjected to macrophage depletion or not. In rat subjected to macrophage depletion, liposomes filled with clodronate were intraperitoneally injected at 1, 3, 6, 11, and 18 days post injury. Rats not subjected to macrophage depletion were intraperitoneally injected with liposomes filled with phosphate buffered saline. Schwann cells were transplanted 1 week post injury in all rats. Biotinylated dextran amine (BDA was injected at thoracic level 5 to evalute axon regeneration. The Basso, Beattie, and Bresnahan locomotor test, Gridwalk test, and sensory test using von Frey filaments were performed to assess functional recovery. Immunohistochemistry was used to detect glial fibrillary acidic protein, neurofilament, and green fluorescent protein (GFP, and also to visulize BDA-labelled axons. The GFP labeled Schwann cell and cyst and lesion volumes were quantified using stained slides. The numbers of BDA-positive axons were also quantified. At 8 weeks after Schwann cell transplantation, there was a significant reduction in cyst and lesion volumes in the combined treatment group compared to Schwann cell transplantation alone. These changes were not associated, however, with improved Schwann cell survival, axon growth, or locomotor recovery. Although combining Schwann cell transplantation with

  7. Clarifying the link between von Neumann and thermodynamic entropies

    Science.gov (United States)

    Deville, Alain; Deville, Yannick

    2013-01-01

    The state of a quantum system being described by a density operator ρ, quantum statistical mechanics calls the quantity - kTr( ρln ρ), introduced by von Neumann, its von Neumann or statistical entropy. A 1999 Shenker's paper initiated a debate about its link with the entropy of phenomenological thermodynamics. Referring to Gibbs's and von Neumann's founding texts, we replace von Neumann's 1932 contribution in its historical context, after Gibbs's 1902 treatise and before the creation of the information entropy concept, which places boundaries into the debate. Reexamining von Neumann's reasoning, we stress that the part of his reasoning implied in the debate mainly uses thermodynamics, not quantum mechanics, and identify two implicit postulates. We thoroughly examine Shenker's and ensuing papers, insisting upon the presence of open thermodynamical subsystems, imposing us the use of the chemical potential concept. We briefly mention Landau's approach to the quantum entropy. On the whole, it is shown that von Neumann's viewpoint is right, and why Shenker's claim that von Neumann entropy "is not the quantum-mechanical correlate of thermodynamic entropy" can't be retained.

  8. Post transplant lymphoproliferative disease in pediatric solid organ transplant patients: A possible role for [{sup 18}F]-FDG-PET(/CT) in initial staging and therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Falck, C. von [Department of Diagnostic Radiology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany)], E-mail: Falck.Christian.von@mh-hannover.de; Maecker, B. [Department of Pediatric Hematology and Oncology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Schirg, E. [Department of Diagnostic Radiology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Boerner, A.R.; Knapp, W.H. [Department of Nuclear Medicine, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Klein, C. [Department of Pediatric Hematology and Oncology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany); Galanski, M. [Department of Diagnostic Radiology, Medizinische Hochschule Hannover (Medical School Hanover), Carl-Neuberg-Strasse 1, 30625 Hannover (Germany)

    2007-09-15

    Post transplant lymphoproliferative disease (PTLD) is a severe complication after solid organ or bone marrow transplantation. In pediatric transplant recipients PTLD is the most common malignancy. The aim of this study was to evaluate a possible role for positron emission tomography with [{sup 18}F]-2-fluoro-2-desoxy-glucose (FDG) in the initial staging and in therapy monitoring of pediatric patients suffering from biopsy-proven CD20-positive PTLD after solid organ transplantation. Seven pediatric patients were included. All available imaging studies - CT (n = 15), MRI (n = 16) and PET/PETCT (n = 16) - were reviewed on a lesion by lesion base. The performance of FDG-PET in the initial staging and during therapy with a chimeric anti-CD20 antibody was compared to conventional cross sectional imaging and correlated with the clinical outcome. FDG-PET identified all sites of disease as shown by CT/MRI and helped to clarify the significance of equivocal findings. The initial stage of disease was correctly identified by FDG-PET alone when compared to CT/MRI. During therapy, FDG-PET was superior to conventional cross-sectional imaging in the early evaluation of response.

  9. MR imaging of hepatic metastasis in patients with malignant melanoma: Evaluation of suspected lesions screened at contrast-enhanced CT

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Tateishi, Ukihide; Tsurusaki, Masakatsu; Arai, Yasuaki; Yamazaki, Naoya; Sugimura, Kazuro

    2012-01-01

    Purpose: To evaluate the magnetic resonance (MR) imaging feature of suspected hepatic metastasis in patients with malignant melanoma which showed intermediate findings on screened contrast-enhanced computed tomography (CECT). Materials and methods: MR imaging was performed in 38 patients (22 men, 16 women; mean age, 58 years) whose CECT findings were intermediate. Hepatic metastases had been diagnosed on MR imaging in 23 of the 38 patients. Verification of hepatic metastasis was made by histological examination: ultrasonographic-guided needle biopsy (n = 3), autopsy (n = 3), and surgical resection (n = 1), or by an obvious progression in number and/or size of the lesions on follow-up MR imaging (n = 24). Two diagnostic radiologists reviewed MR images by consensus. The median follow-up duration was 14.2 months. Results: Abnormal findings were detected in 31 patients on MR images, and undetected in the remaining seven patients resulting in false-positive on CECT. The mean size of the lesion was 11.0 mm. False-positive results were obtained in two lesions which disappeared on follow-up MR imaging. In six patients, lesions were considered as hepatic cysts on MR images. As a result, a total of 35 hepatic metastases were detected on MR images. Of these, 18 patients demonstrated typical melanotic appearance on MR images which showed shortened T1 and T2 relaxation times, and five patients demonstrated atypical melanotic appearance. In 16 patients, extra-hepatic metastases were also developed. Conclusion: MR imaging could rule out hepatic metastasis in patients with malignant melanoma which showed intermediate findings on screened CECT, and could detect additional extra-hepatic metastases.

  10. Perfusion abnormalities in congenital and neoplastic pulmonary disease: comparison of MR perfusion and multislice CT imaging

    International Nuclear Information System (INIS)

    Boll, Daniel T.; Lewin, Jonathan S.; Young, Philip; Gilkeson, Robert C.; Siwik, Ernest S.

    2005-01-01

    The aim of this work was to assess magnetic resonance (MR) perfusion patterns of chronic, nonembolic pulmonary diseases of congenital and neoplastic origin and to compare the findings with results obtained with pulmonary, contrast-enhanced multislice computed tomography (CT) imaging to prove that congenital and neoplastic pulmonary conditions require MR imaging over the pulmonary perfusion cycle to successfully and directly detect changes in lung perfusion patterns. Twenty-five patients underwent concurrent CT and MR evaluation of chronic pulmonary diseases of congenital (n=15) or neoplastic (n=10) origin. Analysis of MR perfusion and contrast-enhanced CT datasets was realized by defining pulmonary and vascular regions of interest in corresponding positions. MR perfusion calculated time-to-peak enhancement, maximal enhancement and the area under the perfusion curve. CT datasets provided pulmonary signal-to-noise ratio measurements. Vessel centerlines of bronchial arteries were determined. Underlying perfusion type, such as pulmonary arterial or systemic arterial supply, as well as regions with significant variations in perfusion were determined statistically. Analysis of the pulmonary perfusion pattern detected pulmonary arterial supply in 19 patients; six patients showed systemic arterial supply. In pulmonary arterial perfusion, MR and multislice CT imaging consistently detected the perfusion type and regions with altered perfusion patterns. In bronchial arterial supply, MR perfusion and CT imaging showed significant perfusion differences. Patients with bronchial arterial supply had bronchial arteries ranging from 2.0 to 3.6 mm compared with submillimeter diameters in pulmonary arterial perfusion. Dynamic MR imaging of congenital and neoplastic pulmonary conditions allowed characterization of the pulmonary perfusion type. CT imaging suggested the presence of systemic arterial perfusion by visualizing hypertrophied bronchial arteries. (orig.)

  11. Privatiserung von Geschichte. Probleme einer differenzierten Aufarbeitung

    Directory of Open Access Journals (Sweden)

    Birthe Kundrus

    2000-11-01

    Full Text Available Ausgangspunkt der Untersuchung von Vera Neumann ist die These, daß im Krieg Erlebtes und Erlittenes in den Wiederaufbau- und Wirtschaftswunderjahren Westdeutschlands einem Thematisierungstabu unterlegen sei. Anhand von 50 Interviews, die in den 80er Jahren im Rahmen des von Lutz Niethammer geleiteten Projekts „Lebensgeschichte und Sozialgeschichte im Ruhrgebiet 1930–1960“ (LUSIR entstanden sind und die sie jetzt anhand der Tonbandprotokolle und Abschriften ein zweites Mal auswertet, möchte die Historikerin diese Verschüttungen aufspüren. Im Anschluß an Niethammers These der „Privatisierung von Geschichte“ will sie zeigen, daß seelische und körperliche Kriegsfolgen wie Deprivations- und Überlastungsgefühle, der Verlust von Angehörigen und Kriegsbeschädigungen „privatisiert“, d.h. an die Familien übertragen wurden. Dort seien dann in erster Linie die weiblichen Familienmitglieder mit der Versorgungs- und Pflegearbeit konfrontiert worden. An vier Fallbeispiele schließt sich eine detaillierte Auswertung des gesamten Interviewmaterials an. Diesen Teilen folgt ein Abschnitt zur staatlichen Kriegsopferversorgung in der frühen Bundesrepublik.

  12. Reproducibility of Quantitative Brain Imaging Using a PET-Only and a Combined PET/MR System

    Directory of Open Access Journals (Sweden)

    Martin L. Lassen

    2017-07-01

    Full Text Available The purpose of this study was to test the feasibility of migrating a quantitative brain imaging protocol from a positron emission tomography (PET-only system to an integrated PET/MR system. Potential differences in both absolute radiotracer concentration as well as in the derived kinetic parameters as a function of PET system choice have been investigated. Five healthy volunteers underwent dynamic (R-[11C]verapamil imaging on the same day using a GE-Advance (PET-only and a Siemens Biograph mMR system (PET/MR. PET-emission data were reconstructed using a transmission-based attenuation correction (AC map (PET-only, whereas a standard MR-DIXON as well as a low-dose CT AC map was applied to PET/MR emission data. Kinetic modeling based on arterial blood sampling was performed using a 1-tissue-2-rate constant compartment model, yielding kinetic parameters (K1 and k2 and distribution volume (VT. Differences for parametric values obtained in the PET-only and the PET/MR systems were analyzed using a 2-way Analysis of Variance (ANOVA. Comparison of DIXON-based AC (PET/MR with emission data derived from the PET-only system revealed average inter-system differences of −33 ± 14% (p < 0.05 for the K1 parameter and −19 ± 9% (p < 0.05 for k2. Using a CT-based AC for PET/MR resulted in slightly lower systematic differences of −16 ± 18% for K1 and −9 ± 10% for k2. The average differences in VT were −18 ± 10% (p < 0.05 for DIXON- and −8 ± 13% for CT-based AC. Significant systematic differences were observed for kinetic parameters derived from emission data obtained from PET/MR and PET-only imaging due to different standard AC methods employed. Therefore, a transfer of imaging protocols from PET-only to PET/MR systems is not straightforward without application of proper correction methods.Clinical Trial Registration:www.clinicaltrialsregister.eu, identifier 2013-001724-19

  13. Fluorine-18 deoxyglucose uptake in sarcoidosis measured with positron emission tomography

    International Nuclear Information System (INIS)

    Brudin, L.H.; Valind, S.O.; Rhodes, C.G.; Pantin, C.F.; Sweatman, M.; Jones, T.; Hughes, J.M.B.

    1994-01-01

    Regional pulmonary glucose metabolism (MR glu ; μmol h -1 g -1 ), extravascular lung density (D EV ; g cm -3 ) and vascular volume (V B ; ml cm -3 ) were measured in a single midthoracic transaxial slice (-2 cm thick) using positron emission tomography (PET) in seven patients with histologically proven sarcoidosis. The measurements were repeated 1-7 months later after steroid therapy (in two cases, no treatment) in order to assess MR glu as an index of inflammation and relate it to routine pulmonary function tests, chest radiography and serum angiotensin converting enzyme (SACE) levels. MR glu was computed from serial lung scans and peripheral venous blood samples for 60 min following an i.v. injection of 18 F-2-fluoro-2-deoxy-D-glucose ( 18 FDG). Both MR glu (which was increased in six of seven patients) and elevated SACE levels returned to normal in those patients treated with high-dose steroids. Regional vascular volume was normal in six of seven cases and did not change significantly with therapy. The high tissue density measured in all patients decreased significantly in two of three patients treated with 40 mg prednisolone daily. The abnormal MR glu observed in active sarcoidosis becomes normal pari passu with SACE levels during high-dose steroid therapy. We conclude that MR glu measured with 18 FDG and PET may reflect ''disease activity'' in sarcoidosis in quantitative terms (per gram lung tissue) and in respect of disease distribution. (orig.)

  14. Erzeugung gleichverteilter Stichproben von Lozenge-Teilungen mittels Kopplung von Markovketten

    OpenAIRE

    Keller, Peter

    2011-01-01

    Aus dem Inhalt: 1 Einleitung 2 Eigenschaften der Lozengeteilungen 3 Coupling From The Past (CFTP) 4 Simulation von uniform verteilten Lozengeteilungen 5 Programmlisting und Diskussion der Implementierung 6 Ausblick A Anhang

  15. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  16. Visualisierung von typisierten Links in Linked Data

    Directory of Open Access Journals (Sweden)

    Georg Neubauer

    2017-09-01

    Full Text Available Das Themengebiet der Arbeit behandelt Visualisierungen von typisierten Links in Linked Data. Die wissenschaftlichen Gebiete, die im Allgemeinen den Inhalt des Beitrags abgrenzen, sind das Semantic Web, das Web of Data und Informationsvisualisierung. Das Semantic Web, das von Tim Berners Lee 2001 erfunden wurde, stellt eine Erweiterung zum World Wide Web (Web 2.0 dar. Aktuelle Forschungen beziehen sich auf die Verknüpfbarkeit von Informationen im World Wide Web. Um es zu ermöglichen, solche Verbindungen wahrnehmen und verarbeiten zu können sind Visualisierungen die wichtigsten Anforderungen als Hauptteil der Datenverarbeitung. Im Zusammenhang mit dem Sematic Web werden Repräsentationen von zuhammenhängenden Informationen anhand von Graphen gehandhabt. Der Grund des Entstehens dieser Arbeit ist in erster Linie die Beschreibung der Gestaltung von Linked Data-Visualisierungskonzepten, deren Prinzipien im Rahmen einer theoretischen Annäherung eingeführt werden. Anhand des Kontexts führt eine schrittweise Erweiterung der Informationen mit dem Ziel, praktische Richtlinien anzubieten, zur Vernetzung dieser ausgearbeiteten Gestaltungsrichtlinien. Indem die Entwürfe zweier alternativer Visualisierungen einer standardisierten Webapplikation beschrieben werden, die Linked Data als Netzwerk visualisiert, konnte ein Test durchgeführt werden, der deren Kompatibilität zum Inhalt hatte. Der praktische Teil behandelt daher die Designphase, die Resultate, und zukünftige Anforderungen des Projektes, die durch die Testung ausgearbeitet wurden.

  17. MR-CT registration using a Ni-Ti prostate stent in image-guided radiotherapy of prostate cancer.

    Science.gov (United States)

    Korsager, Anne Sofie; Carl, Jesper; Østergaard, Lasse Riis

    2013-06-01

    In image-guided radiotherapy of prostate cancer defining the clinical target volume often relies on magnetic resonance (MR). The task of transferring the clinical target volume from MR to standard planning computed tomography (CT) is not trivial due to prostate mobility. In this paper, an automatic local registration approach is proposed based on a newly developed removable Ni-Ti prostate stent. The registration uses the voxel similarity measure mutual information in a two-step approach where the pelvic bones are used to establish an initial registration for the local registration. In a phantom study, the accuracy was measured to 0.97 mm and visual inspection showed accurate registration of all 30 data sets. The consistency of the registration was examined where translation and rotation displacements yield a rotation error of 0.41° ± 0.45° and a translation error of 1.67 ± 2.24 mm. This study demonstrated the feasibility for an automatic local MR-CT registration using the prostate stent.

  18. Correction of distortion of MR pictures for MR-guided robotic sterotactic procedures

    International Nuclear Information System (INIS)

    Jonckheere, E.A.; Kwoh, Y.S.

    1988-01-01

    Ever since magnetic resonance (MR) invaded the medical imaging field, it has played an increasingly important role and is even currently being considered for stereotactic guidance of probes in the brain. While MR pictures indeed convey more clinical information than CT, the geometry of MR pictures is, unfortunately, not as accurate as the geometry of CT pictures. In other words, if a square grid phantom is scanned, then the CT picture will show a square grid, while the MR picture will rather reveal a distorted grid. This distortion is primarily due to small variations in the static magnetic field. This small distortion does not impede radiological diagnosis; however, it is a source of concern if one contemplates utilizing the MR pictures for accurate stereotactic positioning of a probe at a very precise point in the brain. Another area of application where the distortion of the MR picture should be compensated for is the superposition of CT and MR pictures so that both informations could be used for diagnosis or stereotactic purposes. This paper essentially addresses the nonlinear distortion of MR pictures and how it could be compensated for through software manipulation of the MR picture

  19. Proton-MR-spectroscopy of vertebral bone marrow: normal age- and sex-related patterns; Protonen-MR-Spektroskopie des Wirbelkoerpermarks. Analyse des physiologischen Signalverhaltens

    Energy Technology Data Exchange (ETDEWEB)

    Jung, C.M.; Kugel, H.; Schulte, O.; Heindel, W. [Koeln Univ. (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    2000-08-01

    Background. Magnetic resonance imaging has shown to be a sensitive method for diagnostics of the red bone marrow, the composition of which changes physiologically and during pathological processes. However, the interpretation of MRI in patients with disorders of the red bone marrow is very difficult. The aim of this study was the characterization of the proton spectrum of healthy bone marrow and its age- and sex-dependent changes to obtain a data basis for measurements in patients. Methods. 154 healthy volunteers have been examined. After imaging, a spectroscopic measurement was performed to determine the relative intensities of fat and water, and their respective T2 times. Results. While T2 (water: 46.9 ms and fat: 75.4 ms) does not depend on age or sex, the relative signal intensity of fat increases by about 6% per decade. In the age groups between 31 and 50 years it diverses significantly between men (43.5%) and woman (32.5%) (p{<=}0.01, Mann-Whitney-Test). Conclusions. Proton spectroscopy can increase the reliability of diagnosis by offering information on composition of the marrow. The analysis of spectroscopic measurements requires exact knowledge about normal physiological values. (orig.) [German] Hintergrund. Die Magnetresonanztomographie ist ein sensitives bildgebendes Verfahren zur Beurteilung des roten Knochenmarkraums. Die Zusammensetzung des Knochenmarks aendert sich mit zunehmenden Alter, aber auch bei krankhaften Prozessen. Als Basis fuer die Interpretation von Patientenuntersuchungen bei Erkrankungen des haematopoetischen Systems wurden im Rahmen der vorliegenden Studie an Probanden die alters- und geschlechtsabhaengigen Veraenderungen des Protoenenspektrums aus dem Knochenmarkraum analysiert. Methode. Bei 154 gesunden Probanden wurde nach einer MR-Bildgebung eine spektroskopische Messung des Lendenwirbelkoerpermarks zur Bestimmung der relativen Fett- und Wasseranteile sowie der T2-Relaxationszeiten durchgefuehrt. Ergebnis. Die T2-Zeiten (46,9 ms

  20. Antimyosin imaging in cardiac transplant rejection

    International Nuclear Information System (INIS)

    Johnson, L.L.; Cannon, P.J.

    1991-01-01

    Fab fragments of antibodies specific for cardiac myosin have been labeled with indium-111 and injected intravenously into animals and into patients with heart transplants. The antibodies, developed by Khaw, Haber, and co-workers, localize in cardiac myocytes that have been damaged irreversibly by ischemia, myocarditis, or the rejection process. After clearance of the labeled antibody from the cardiac blood pool, planar imaging or single photon emission computed tomography is performed. Scintigrams reveal the uptake of the labeled antimyosin in areas of myocardium undergoing transplant rejection. In animal studies, the degree of antimyosin uptake appears to correlate significantly with the degree of rejection assessed at necropsy. In patients, the correlation between scans and pathologic findings from endomyocardial biopsy is not as good, possibly because of sampling error in the endomyocardial biopsy technique. The scan results at 1 year correlate with either late complications (positive) or benign course (negative). Current limitations of the method include slow blood clearance, long half-life of indium-111, and hepatic uptake. Overcoming these limitations represents a direction for current research. It is possible that from these efforts a noninvasive approach to the diagnosis and evaluation of cardiac transplantation may evolve that will decrease the number of endomyocardial biopsies required to evaluate rejection. This would be particularly useful in infants and children. 31 references

  1. Diffusion von Leerstelleninseln auf Cu(111)

    NARCIS (Netherlands)

    Verheij, Laurens K.; Schlößer, Dietmar; Rosenfeld, Georg

    1998-01-01

    Die zufällige Bewegung von Leerstelleninseln wurde bisher vorwiegend in einem Bild beschrieben, das von der Diffusion einzelner Atome ausgeht. In diesem Bild kann man Inseldiffusion durch die Einstein-Beziehung für Brownsche Bewegung ((Δ r)2 = 4 D Δ t) beschreiben. Für die Diffusionskonstante D wird

  2. [Heinz von zur Mühlen. Das Bürgertum Fordert Blut. Ein Bolschewistiches Flugblatt von 1918] / Paul Kaegbein

    Index Scriptorium Estoniae

    Kaegbein, Paul

    2007-01-01

    Arvustus: Heinz von zur Mühlen. Das Bürgertum Fordert Blut. Ein Bolschewistiches Flugblatt von 1918. In : Ostseeprovinzen, baltische Staaten und das Nationale. Münster : LIT, 2005, lk. 403-414. 1918. aastast pärit lendlehest, mille käekirja järgi otsustades on kirjutanud Viktor Kingissepp

  3. Intraoperative use of an open midfield MR scanner in the surgical treatment of cerebral gliomas; Intraoperative Nutzung eines offenen Mittelfeld-MRT waehrend der chirurgischen Therapie zerebraler Gliome

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.P.; Schulz, T.; Dietrich, J.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany); Trantakis, C. [Klinik und Poliklinik fuer Neurochirurgie, Univ. Leipzig (Germany)

    2003-07-01

    The aim of the present study was to evaluate the effectiveness of intraoperative MRI guidance in achieving more gross-total resection in case of primary brain tumors. We studied 12 patients with low-grade glioma and 19 patients with high-grade glioma who underwent surgery within a vertically open 0.5T MR system. After initial imaging, the resection was stopped at the point in which the neurosurgeon considered the resection complete by viewing the operation field. At this time, intraoperative MRI was repeated (''first control'') to identify any residual tumor. Areas of tumor-suspected tissue were localized and resected, with the exception of tissue adjacent to eloquent areas. Final imaging was carried out before closing the craniotomy. Comparison of ''first control'' and final imaging revealed a decrease of residual tumor volume from 32% to 4.3% in low-grade gliomas, and from 29% to 10% in high-grade gliomas. Intraoperative MRI allows a clear optimization of microsurgical resection of both low-grade and high-grade gliomas. (orig.) [German] Ziel der Untersuchung war es, die Effektivitaet des Einsatzes der intraoperativen MRT bei der Resektion gliogener Hirntumoren zu pruefen. 12 Patienten mit niedriggradigem Gliom und 19 Patienten mit Glioblastom wurden in einem vertikal offenen 0,5-T-MRT operiert. Nach der initialen Bildgebung erfolgte die Resektion bis zu dem Zeitpunkt, an dem der Neurochirurg kein Tumorgewebe mehr im OP-Situs abgrenzen konnte. Zu diesem Zeitpunkt erfolgte eine erneute MRT (''= erste Kontrolle'') zur Visualisierung nur MR-tomographisch darstellbaren Resttumors. Solche Areale wurden im OP-Situs lokalisiert und mit Ausnahme von Strukturen in der Naehe eloquenter Hirnareale reseziert. Vor Verschluss des Schaedels erfolgte eine abschliessende MR-Kontrolle. Durch Einsatz der intraoperativen MRT konnte eine Absenkung des relativen Resttumorvolumens von 32% auf 4,3% bei niediggradigen Gliomen und

  4. Staging of primary head and neck tumors and detection of recurrences; Staging und Rezidivdiagnostik von Tumoren im Kopf-Hals-Bereich

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S. [Klinikum der Ruhr-Univ. Bochum, Marienhospital, Herne (Germany). Klinik fuer Radiologie und Nuklearmedizin; Baum, R.P. [Zentralklinik Bad Berka (Germany). Klinik fuer Nuklearmedizin/PET-Zentrum; Knecht, R. [Frankfurt Univ., Frankfurt am Main (Germany). Zentrum fuer Hals-Nasen-Ohren-Heilkunde; Hoer, G. [Frankfurt Univ., Frankfurt/Main (Germany). Klinik fuer Nuklearmedizin

    2001-04-01

    Squamous cell carcinomas represent the vast majority of all malignant tumors of the head and neck region. Lymph node involvement is the most important prognostic factor affecting survival of patients with head and neck cancer. The effectiveness of surgical treatment depends on the complete excision of all tumor tissue and an accurate preoperative diagnosis. Tumor-node-metastasis (TNM) staging is therefore mandatory. In comparison to positron emission tomography with fluorine-18 fluorodeoxyglucose (FDG PET), morphological imaging modalities (CT, MRI) have been applied for the localization of primary head and neck tumors because of their better anatomical resolution. Metabolic tumor imaging using FDG PET is superior to morphological imaging by CT and MRI in the detection of small cervical lymph node metastases (Class 1a indication). Increased FDG utpake has also been observed in benign inflammatory lesions after radiation therapy, therefore detection of local recurrence with FDG PET can be problematic. To ensure a high diagnostic accuracy it is been suggested to perform FDG PET not earlier than 3 months after radiation therapy (Class 1a indication for the diagnosis of local recurrence). (orig.) [German] Plattenepithelkarzinome stellen mit 90% den ueberwiegenden Anteil von malignen Tumoren des Kopf-Hals-Bereiches dar. Ein wesentlicher prognostischer Faktor ist das Vorhandensein von Lymphknotenmetastasen. Die Entscheidung ueber das richtige therapeutische Vorgehen ist von der genauen Festlegung des primaeren Tumorstadiums abhaengig. Die Positronenemissionstomographie (PET) unter Verwendung von {sup 18}F-markierter 2-Fluoro-2-Deoxy-D-Glukose (FDG) ist fuer das T-Staging gegenueber den morphologisch orientierten Verfahren (CT, MRT) im allgemeinen ohne klinischen Nutzen. Als funktionsorientiertes Verfahren ist die FDG-PET bei der Diagnostik von Lymphknotenmetastasen den anatomisch orientierten Untersuchungsverfahren ueberlegen (Klasse-1a-Indikation), da sie nicht alleine

  5. MR-guided stereotactic neurosurgery-comparison of fiducial-based and anatomical landmark transformation approaches

    International Nuclear Information System (INIS)

    Hunsche, S; Sauner, D; Maarouf, M; Hoevels, M; Luyken, K; Schulte, O; Lackner, K; Sturm, V; Treuer, H

    2004-01-01

    For application in magnetic resonance (MR) guided stereotactic neurosurgery, two methods for transformation of MR-image coordinates in stereotactic, frame-based coordinates exist: the direct stereotactic fiducial-based transformation method and the indirect anatomical landmark method. In contrast to direct stereotactic MR transformation, indirect transformation is based on anatomical landmark coregistration of stereotactic computerized tomography and non-stereotactic MR images. In a patient study, both transformation methods have been investigated with visual inspection and mutual information analysis. Comparison was done for our standard imaging protocol, including t2-weighted spin-echo as well as contrast enhanced t1-weighted gradient-echo imaging. For t2-weighted spin-echo imaging, both methods showed almost similar and satisfying performance with a small, but significant advantage for fiducial-based transformation. In contrast, for t1-weighted gradient-echo imaging with more geometric distortions due to field inhomogenities and gradient nonlinearity than t2-weighted spin-echo imaging, mainly caused by a reduced bandwidth per pixel, anatomical landmark transformation delivered markedly better results. Here, fiducial-based transformation yielded results which are intolerable for stereotactic neurosurgery. Mean Euclidian distances between both transformation methods were 0.96 mm for t2-weighted spin-echo and 1.67 mm for t1-weighted gradient-echo imaging. Maximum deviations were 1.72 mm and 3.06 mm, respectively

  6. MR-guided stereotactic neurosurgery-comparison of fiducial-based and anatomical landmark transformation approaches

    Energy Technology Data Exchange (ETDEWEB)

    Hunsche, S [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Sauner, D [Institute for Diagnostic and Interventional Radiology, Friedrich-Schiller-University of Jena, Jena (Germany); Maarouf, M [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Hoevels, M [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Luyken, K [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Schulte, O [Department of Radiology, University of Cologne, Cologne (Germany); Lackner, K [Department of Radiology, University of Cologne, Cologne (Germany); Sturm, V [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Treuer, H [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany)

    2004-06-21

    For application in magnetic resonance (MR) guided stereotactic neurosurgery, two methods for transformation of MR-image coordinates in stereotactic, frame-based coordinates exist: the direct stereotactic fiducial-based transformation method and the indirect anatomical landmark method. In contrast to direct stereotactic MR transformation, indirect transformation is based on anatomical landmark coregistration of stereotactic computerized tomography and non-stereotactic MR images. In a patient study, both transformation methods have been investigated with visual inspection and mutual information analysis. Comparison was done for our standard imaging protocol, including t2-weighted spin-echo as well as contrast enhanced t1-weighted gradient-echo imaging. For t2-weighted spin-echo imaging, both methods showed almost similar and satisfying performance with a small, but significant advantage for fiducial-based transformation. In contrast, for t1-weighted gradient-echo imaging with more geometric distortions due to field inhomogenities and gradient nonlinearity than t2-weighted spin-echo imaging, mainly caused by a reduced bandwidth per pixel, anatomical landmark transformation delivered markedly better results. Here, fiducial-based transformation yielded results which are intolerable for stereotactic neurosurgery. Mean Euclidian distances between both transformation methods were 0.96 mm for t2-weighted spin-echo and 1.67 mm for t1-weighted gradient-echo imaging. Maximum deviations were 1.72 mm and 3.06 mm, respectively.

  7. Diagnostic imaging of Klippel-Feil syndrome: conventional radiography, CT and MR imaging. Case report

    International Nuclear Information System (INIS)

    Jochens, R.; Schubeus, P.; Steinkamp, H.J.; Menzhausen, L.; Felix, R.

    1993-01-01

    In two patients with Klippel-Feil syndrome, type II radiographic findings of the malformation are shown in the cervical spine and the craniocervical junction. Conventional X-rays of the cervical spine in the AP and lateral view and conventional tomography as well as CT of the cervical spine were obtained in both patients. One of the two patients additionally underwent MR imaging. Findings of the different imaging modalities are compared with each other. (orig.) [de

  8. Pharmakobotanische Untersuchungen von Lavendelsorten auf dem Plattensee- Plateau

    Directory of Open Access Journals (Sweden)

    Tóth, Frida

    2014-09-01

    Full Text Available Auf dem Hof Dörgicsei Levendula Major GmbH wurden 9 Lavendelsorten (6 Sorten von Lavandula angustifolia und 3 Sorten von Lavandula x intermedia untersucht. Neben den morphologischen und Wachstumseigenschaften wurden auch Frisch- und Trockengewichte bewertet. Quantitative und qualitative Untersuchungen von den Blüten- und Ätherischöldrogen wurden auch durchgeführt. Die statistische Analyse zeigte signifikant höhere Erträge bei den Sorten L. angustifolia ’Essence Purple’ und L. x intermedia ’Edelweiss’. Gehalt und Zusammensetzung von ätherischem Öl war eindeutig bei der Sorte L. angustifolia ’Ellagance Purple’ am günstigsten.

  9. Speziation von Gadolinium-MRT-Kontrastmitteln in Umweltmatrizes

    OpenAIRE

    Lindner, Uwe

    2017-01-01

    Gd-Kontrastmittel werden in der Medizin für die Magnetresonanztomographie (MRT) benötigt, um einen besseren Bildkontrast zu erzielen. Nach der Anwendung gelangen diese Arzneimittel über das Abwasser in die Klärwerke und von dort in die jeweiligen anliegenden Oberflächengewässer. Somit wird es notwendig, den Verbleib der Gd-MRT-Kontrastmittel in der Umwelt zu verfolgen und aufzuklären. In dieser Arbeit werden für die Analyse von Umweltproben Methoden zur Speziesanalytik von Gd-Kontrastmitteln ...

  10. Positron Emission Tomography: Its 65 years

    International Nuclear Information System (INIS)

    Del Guerra, A.; Belcari, N.; Bisogni, M.

    2016-01-01

    Positron Emission Tomography (PET) is a well-established imaging technique for in vivo molecular imaging. In this review after a brief history of PET there are presented its physical principles and the technology that has been developed for bringing PET from a bench experiment to a clinical indispensable instrument. The limitations and performance of the PET tomographs are discussed, both as for the hardware and software aspects. The status of art of clinical, preclinical and hybrid scanners (i.e., PET/CT and PET/MR) is reported. Finally the actual trend and the recent and future technological developments are fully illustrated.

  11. 1H-MR spectroscopy in evaluating the effect of neural stem cell transplantation on Alzheimer's disease in an APP-PS1 transgenic mouse model

    International Nuclear Information System (INIS)

    Chen Shuangqing; Cai Qing; Shen Yuying; Li Minghua; Zhang Wei; Wang Peijun; Zang Fengchao; Teng Gaojun

    2012-01-01

    Objective: To explore the value of 1 H-MRS on the evaluation of Alzheimer's disease (AD) with neural stem cells (NSCs) transplantation in an APP-PS1 double transgenic (tg) AD mouse model. Methods: NSCs from C57BL/6 mice were cultured and amplified.APP-PS1 tg mice (n =30) aged 12 months were used as the study group, and mild-type mice (n=15) were used as the control group. Animals in the study group were randomized into two subgroups, the AD mice in one subgroup received NSCs transplantation (NSCs group) and in another subgroup received phosphate buffer saline (PBS, PBS group)in bilateral hippocampal CA1. Animals in the control group were not treated. Using a 7.0 T high-field strength MR imager, 1 H-MRS was performed before and 6 weeks after transplantation to measure the area under the peak of n-acetyl aspartate (NAA),glutamate (Glu), myo-inositol (mI), choline (Cho) and creatine (Cr) in the hippocampal area, NAA/Cr, Glu/Cr, mI/Cr and Cho/Cr ratio were calculated and compared with histopathological results (including Nissl's staining and electron microscope examination). Comparisons among NSCs, PBS and control groups were conducted by one-way ANOVA. Results: NSCs from C57BL/6 mice were cultured successfully. Before transplantation,the mean NAA/Cr, Glu/Cr and mI/Cr in NSCs, PBS and control groups were 0.89 ± 0.05, 0.88 ± 0.04 and 1.15 ± 0.05, 0.40 ± 0.03, 0.39 ± 0.03 and 0.45 ± 0.05, 0.67 ± 0.05, 0.67 ± 0.05 and 0.52 ± 0.04, respectively, and differences were statistically significant (F =148.918,7.529,59.468,P<0.01). There were no significant differences in NAA/Cr,mI/Cr and Glu/Cr ratios between NSCs and PBS groups before transplantation (t=0.147, 0.096, 0.207, P>0.05), but the differences were significant compared with the control group (t=0.255, 0.467, 0.171 and t=0.269, 0.527, 0.151, P<0.05). Six weeks after transplantation,the mean NAA/Cr, Glu/Cr and mI/Cr in three groups were 1.13 ±0.07, 0.86 ±0.05 and 1.14 ±0.05, 0.45 ± 0.04, 0.38 ± 0

  12. MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

    Science.gov (United States)

    Izquierdo-Garcia, David; Catana, Ciprian

    2016-04-01

    Attenuation correction (AC) is one of the most important challenges in the recently introduced combined PET/magnetic resonance (MR) scanners. PET/MR AC (MR-AC) approaches aim to develop methods that allow accurate estimation of the linear attenuation coefficients of the tissues and other components located in the PET field of view. MR-AC methods can be divided into 3 categories: segmentation, atlas, and PET based. This review provides a comprehensive list of the state-of-the-art MR-AC approaches and their pros and cons. The main sources of artifacts are presented. Finally, this review discusses the current status of MR-AC approaches for clinical applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Diagnostic performance of MR imaging in the assessment of subchondral fractures in avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, Lee-Ren [E-Da Hospital and I-Shou University, Department of Radiology, Kaohsiung County (China); Chen, Clement K.H.; Pan, Huay-Ben; Yang, Chien-Fang [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (China); National Yang-Ming University, School of Medicine, Taipei (China); Huang, Yi-Luan [Kaohsiung Veterans General Hospital, Department of Radiology, Kaohsiung (China)

    2009-06-15

    A prospective study was conducted to determine the accuracy of routine magnetic resonance (MR) imaging in correctly identifying subchondral fracture in avascular necrosis of the femoral head without apparent focal collapse on standard radiographs. Spiral computed tomography (CT) with coronal and sagittal reformations and routine MR imaging with spin-echo T1WI and fat-suppressed spin-echo T2WI coronal, axial, and sagittal images were performed in 28 hips of 25 patients (M/F = 20:5; age 16-76 years) suffering from early-stage avascular necrosis of the femoral head on standard radiographs. The MR images were reviewed by a musculoskeletal radiologist and a general radiologist in blinded fashion. Using CT as the standard of reference, the accuracy of MR imaging in diagnosing subchondral fractures in avascular necrosis was evaluated. When the diagnoses of the two readers were compared with each other, only 16 of the 28 diagnoses (57.5%) agreed. Seventeen of the 28 MR imaging readings (60.7%) made by the musculoskeletal radiologist and 15 of the 28 (53.5%) made by the general radiologist agreed with those of the CT standard. False-positive diagnosis (that is, diagnosis of fracture when no fracture could be seen on CT) was more common than false-negative diagnosis. The accuracy of routine MR imaging in the evaluation of subchondral fracture is not satisfactory. False-positive diagnosis is not uncommon. Interpretation of routine MR imaging readout should be guarded. (orig.)

  14. Diagnostic performance of MR imaging in the assessment of subchondral fractures in avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Yeh, Lee-Ren; Chen, Clement K.H.; Pan, Huay-Ben; Yang, Chien-Fang; Huang, Yi-Luan

    2009-01-01

    A prospective study was conducted to determine the accuracy of routine magnetic resonance (MR) imaging in correctly identifying subchondral fracture in avascular necrosis of the femoral head without apparent focal collapse on standard radiographs. Spiral computed tomography (CT) with coronal and sagittal reformations and routine MR imaging with spin-echo T1WI and fat-suppressed spin-echo T2WI coronal, axial, and sagittal images were performed in 28 hips of 25 patients (M/F = 20:5; age 16-76 years) suffering from early-stage avascular necrosis of the femoral head on standard radiographs. The MR images were reviewed by a musculoskeletal radiologist and a general radiologist in blinded fashion. Using CT as the standard of reference, the accuracy of MR imaging in diagnosing subchondral fractures in avascular necrosis was evaluated. When the diagnoses of the two readers were compared with each other, only 16 of the 28 diagnoses (57.5%) agreed. Seventeen of the 28 MR imaging readings (60.7%) made by the musculoskeletal radiologist and 15 of the 28 (53.5%) made by the general radiologist agreed with those of the CT standard. False-positive diagnosis (that is, diagnosis of fracture when no fracture could be seen on CT) was more common than false-negative diagnosis. The accuracy of routine MR imaging in the evaluation of subchondral fracture is not satisfactory. False-positive diagnosis is not uncommon. Interpretation of routine MR imaging readout should be guarded. (orig.)

  15. MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.

    Science.gov (United States)

    Chen, Kevin T; Salcedo, Stephanie; Chonde, Daniel B; Izquierdo-Garcia, David; Levine, Michael A; Price, Julie C; Dickerson, Bradford C; Catana, Ciprian

    2018-03-08

    Subject motion in positron emission tomography (PET) studies leads to image blurring and artifacts; simultaneously acquired magnetic resonance imaging (MRI) data provides a means for motion correction (MC) in integrated PET/MRI scanners. To assess the effect of realistic head motion and MR-based MC on static [ 18 F]-fluorodeoxyglucose (FDG) PET images in dementia patients. Observational study. Thirty dementia subjects were recruited. 3T hybrid PET/MR scanner where EPI-based and T 1 -weighted sequences were acquired simultaneously with the PET data. Head motion parameters estimated from high temporal resolution MR volumes were used for PET MC. The MR-based MC method was compared to PET frame-based MC methods in which motion parameters were estimated by coregistering 5-minute frames before and after accounting for the attenuation-emission mismatch. The relative changes in standardized uptake value ratios (SUVRs) between the PET volumes processed with the various MC methods, without MC, and the PET volumes with simulated motion were compared in relevant brain regions. The absolute value of the regional SUVR relative change was assessed with pairwise paired t-tests testing at the P = 0.05 level, comparing the values obtained through different MR-based MC processing methods as well as across different motion groups. The intraregion voxelwise variability of regional SUVRs obtained through different MR-based MC processing methods was also assessed with pairwise paired t-tests testing at the P = 0.05 level. MC had a greater impact on PET data quantification in subjects with larger amplitude motion (higher than 18% in the medial orbitofrontal cortex) and greater changes were generally observed for the MR-based MC method compared to the frame-based methods. Furthermore, a mean relative change of ∼4% was observed after MC even at the group level, suggesting the importance of routinely applying this correction. The intraregion voxelwise variability of regional SUVRs

  16. Ankle ligamints : comparison of MR arthrography with conventional MR imaging in amputated feet

    International Nuclear Information System (INIS)

    Yoo, Jae Sung; Lee, Sang Yong; Lee, Jeong Min; Han, Young Min; Chung, Kyung Ho; Kim, CHong Soo

    2001-01-01

    To compare magnetic resonance (MR) arthrography with conventional MR imaging in the evaluation of ankle ligaments. Eight freshly amputated human feet underwent conventional MR imaging and MR arthrography. For the former, 1.5-T magnets in the axial, coronal and sagittal planes were used, and T1-weighted sequences were obtained. Following the injection of 6-10 ml of diluted contrast media (Gd-DTPA 1:250), T1-weighted images were obtained in the same positions as conventional MR images. Paired conventional MR imaging and MR arthrography of each ankle ligament were rated on a five-point scale, and to reflect inter-group differences a Wilcoxon singed-rank test was used to compare the different measurements (p<0.05). In two ankles, MR images of the ligaments were correlated with ankle dissection. Anterior and posterior talofibular ligaments were more clearly revealed by MR arthrography than by conventional MR imaging, while calcaneofibular ligaments showed no difference between these two modalities. With regard to deltoid ligaments, visualization of the anterior and posterior tibiotalar ligament was much improved when contrast material was used to outline the ligament's articular aspect. Visualization of the posterior inferior tibiofibular ligament and inferior transverse ligament were also improved when the use of contrast material provided delineation of the articular side of the ligaments and separated them from adjacent bone. In addition, MR arthography was very useful for indentification of the posterior intermalleolar ligament, though its use did not enhance visualization of the calcaneofibular, tibiocalcaneal, spring or tibiospring ligaments. MR arthrography accurately revealed the anatomic details of ankle ligaments, and may therefore be more useful than conventional Mr imaging for evaluation of these structures

  17. Using optical coherence tomography (OCT) to evaluate the status of human donor kidneys (Conference Presentation)

    Science.gov (United States)

    Andrews, Peter M.; Konkel, Brandon; Anderson, Erik; Stein, Matthew; Cooper, Matthew; Verbesey, Jennifer E.; Ghasemian, Seyed; Chen, Yu

    2016-02-01

    The main cause of delayed renal function following the transplant of donor kidneys is ischemic induced acute tubular necrosis (ATN). The ability to determine the degree of ATN suffered by donor kidneys prior to their transplant would enable transplant surgeons to use kidneys that might otherwise be discarded and better predict post-transplant renal function. Currently, there are no reliable tests to determine the extent of ATN of donor kidneys prior to their transplant. In ongoing clinical trials, we have been using optical coherence tomography (OCT) to non-invasively image the superficial proximal tubules of human donor kidneys prior to and following transplant, and correlate these observations with post-transplant renal function. Thus far we have studied over 40 living donor kidneys and 10 cadaver donor kidneys, and demonstrated that this imaging can be performed in a sterile and expeditious fashion in the operating room (OR). Because of many variables associated with a diverse population of donors/recipients and transplant operation parameters, more transplant data must be collected prior to drawing definite conclusions. Nevertheless, our observations have thus far mirrored our previously published laboratory results indicating that damage to the kidney proximal tubules as indicated by tubule swelling is a good measure of post-transplant ATN and delayed graft function. We conclude that OCT is a useful procedure for analyzing human donor kidneys.

  18. CT- and MR-guided interventions in radiology. 2. ed.

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Wilhelm, Kai E.; Ricke, Jens

    2013-01-01

    Revised and extended second edition that covers a broad range of non-vascular interventions guided by CT or MR imaging. Discusses in detail indications, materials, techniques, and results. Includes a comprehensive section on interventional oncology. Richly illustrated source of information and guidance for all radiologists who deal with non-vascular procedures. Interventional radiology is an indispensable and still expanding area of modern medicine that encompasses numerous diagnostic and therapeutic procedures. Cross-sectional imaging modalities such as computed tomography (CT) and magnetic resonance (MR) have emerged as important techniques for non-vascular interventions, including percutaneous biopsy, drainage, ablation, and neurolysis. Various organs, diseases, and lesions can be approached in this way, permitting the treatment and management of tumors, fluid collections, and pain, the embolization of endoleaks, the provision of access to hollow organs, etc. Accordingly, interventional radiology is now an integral component of the interdisciplinary management of numerous disorders. The revised and significantly extended second edition of this volume covers a broad range of non-vascular interventions guided by CT or MR imaging. Indications, materials, techniques, and results are all carefully discussed. A particularly comprehensive section is devoted to interventional oncology as the most rapidly growing branch of interventional radiology. In addition, detailed information is provided that will assist in establishing and developing an interventional service. This richly illustrated book will be a most valuable source of information and guidance for all radiologists who deal with non-vascular procedures.

  19. Characterization, prediction, and correction of geometric distortion in 3 T MR images

    International Nuclear Information System (INIS)

    Baldwin, Lesley N.; Wachowicz, Keith; Thomas, Steven D.; Rivest, Ryan; Gino Fallone, B.

    2007-01-01

    The work presented herein describes our methods and results for predicting, measuring and correcting geometric distortions in a 3 T clinical magnetic resonance (MR) scanner for the purpose of image guidance in radiation treatment planning. Geometric inaccuracies due to both inhomogeneities in the background field and nonlinearities in the applied gradients were easily visualized on the MR images of a regularly structured three-dimensional (3D) grid phantom. From a computed tomography scan, the locations of just under 10 000 control points within the phantom were accurately determined in three dimensions using a MATLAB-based computer program. MR distortion was then determined by measuring the corresponding locations of the control points when the phantom was imaged using the MR scanner. Using a reversed gradient method, distortions due to gradient nonlinearities were separated from distortions due to inhomogeneities in the background B 0 field. Because the various sources of machine-related distortions can be individually characterized, distortions present in other imaging sequences (for which 3D distortion cannot accurately be measured using phantom methods) can be predicted negating the need for individual distortion calculation for a variety of other imaging sequences. Distortions were found to be primarily caused by gradient nonlinearities and maximum image distortions were reported to be less than those previously found by other researchers at 1.5 T. Finally, the image slices were corrected for distortion in order to provide geometrically accurate phantom images

  20. Solitary pulmonary nodules: Comparison of dynamic first-pass contrast-enhanced perfusion area-detector CT, dynamic first-pass contrast-enhanced MR imaging, and FDG PET/CT.

    Science.gov (United States)

    Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Seki, Shinichiro; Tsubakimoto, Maho; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro

    2015-02-01

    To prospectively compare the capabilities of dynamic perfusion area-detector computed tomography (CT), dynamic magnetic resonance (MR) imaging, and positron emission tomography (PET) combined with CT (PET/CT) with use of fluorine 18 fluorodeoxyglucose (FDG) for the diagnosis of solitary pulmonary nodules. The institutional review board approved this study, and written informed consent was obtained from each subject. A total of 198 consecutive patients with 218 nodules prospectively underwent dynamic perfusion area-detector CT, dynamic MR imaging, FDG PET/CT, and microbacterial and/or pathologic examinations. Nodules were classified into three groups: malignant nodules (n = 133) and benign nodules with low (n = 53) or high (n = 32) biologic activity. Total perfusion was determined with dual-input maximum slope models at area-detector CT, maximum and slope of enhancement ratio at MR imaging, and maximum standardized uptake value (SUVmax) at PET/CT. Next, all indexes for malignant and benign nodules were compared with the Tukey honest significant difference test. Then, receiver operating characteristic analysis was performed for each index. Finally, sensitivity, specificity, and accuracy were compared with the McNemar test. All indexes showed significant differences between malignant nodules and benign nodules with low biologic activity (P Dynamic perfusion area-detector CT is more specific and accurate than dynamic MR imaging and FDG PET/CT in the diagnosis of solitary pulmonary nodules in routine clinical practice. © RSNA, 2014.

  1. Spectral theory and quotients in Von Neumann algebras | West ...

    African Journals Online (AJOL)

    In this note we consider to what extent the functional calculus and the spectral theory in von Neumann algebras are preserved by the taking of quotients relative to two-sided ideals of the von Neumann algebra. Keywords:von Neumann algebra, functional calculus, spectral theory, quotient algebras. Quaestiones ...

  2. The quantification of glenoid bone loss in anterior shoulder instability; MR-arthro compared to 3D-CT

    International Nuclear Information System (INIS)

    Markenstein, Jeroen E.; Jaspars, Kjell C.C.J.; Hulst, Victor P.M. van der; Willems, W.J.

    2014-01-01

    The purpose of this study is to investigate if magnetic resonance imaging with intra-articular contrast (MR-arthro) is as reliable as three-dimensionally reconstructed computed tomography imaging (3D-CT) in quantifying the glenoid bone loss in patients with anterior shoulder instability. Thirty-five patients were included. Sagittal MR-arthro and 3D-CT images of the glenoid surface were obtained pre-operatively. Two observers measured these images twice with OsiriX software in a randomized and blinded way. The intraclass correlations (ICC) of the intra- and inter-observer reliability within one method and an additional Bland-Altman plot for calculating agreement between the two methods were obtained. The joint estimates of the intra-observer reliability, taking into account the data from both observer A and B, for 3D-CT and MR-arthro were good to excellent. The intra-observer reliability was 0.938 (95 % CI: 0.879, 0.968) for 3D-CT and 0.799 (95 % CI: 0.639, 0.837) for MR-arthro. The inter-observer reliability between the two observers within one method (3D-CT or MR-arthro) was moderate to good. 3D-CT: 0.724 (95 % CI: 0.236, 0.886) and MR-arthro: 0.534 (95 % CI: 0.128, 0.762). Comparing both the 3D-CT and MR-arthro method, a Bland-Altman plot showed satisfying differences with the majority of outcomes (89 %) within 1 SD. Good to excellent intra- and moderate to good inter-observer correlations and a satisfying Bland-Altman plot when compared to 3D-CT show tendencies that MR-arthro is reliable and valid for measuring bony defects of the glenoid. (orig.)

  3. The quantification of glenoid bone loss in anterior shoulder instability; MR-arthro compared to 3D-CT

    Energy Technology Data Exchange (ETDEWEB)

    Markenstein, Jeroen E. [Onze Lieve Vrouwe Gasthuis, Department of Orthopedic Surgery, Postbox 95500, Amsterdam (Netherlands); Jaspars, Kjell C.C.J. [Van Weel-Bethesda Ziekenhuis, Department of Orthopedic Surgery, Dirksland (Netherlands); Hulst, Victor P.M. van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Postbox 95500, Amsterdam (Netherlands); Willems, W.J. [Delairesse Kliniek, Department of Orthopedic Surgery, Amsterdam (Netherlands)

    2014-04-15

    The purpose of this study is to investigate if magnetic resonance imaging with intra-articular contrast (MR-arthro) is as reliable as three-dimensionally reconstructed computed tomography imaging (3D-CT) in quantifying the glenoid bone loss in patients with anterior shoulder instability. Thirty-five patients were included. Sagittal MR-arthro and 3D-CT images of the glenoid surface were obtained pre-operatively. Two observers measured these images twice with OsiriX software in a randomized and blinded way. The intraclass correlations (ICC) of the intra- and inter-observer reliability within one method and an additional Bland-Altman plot for calculating agreement between the two methods were obtained. The joint estimates of the intra-observer reliability, taking into account the data from both observer A and B, for 3D-CT and MR-arthro were good to excellent. The intra-observer reliability was 0.938 (95 % CI: 0.879, 0.968) for 3D-CT and 0.799 (95 % CI: 0.639, 0.837) for MR-arthro. The inter-observer reliability between the two observers within one method (3D-CT or MR-arthro) was moderate to good. 3D-CT: 0.724 (95 % CI: 0.236, 0.886) and MR-arthro: 0.534 (95 % CI: 0.128, 0.762). Comparing both the 3D-CT and MR-arthro method, a Bland-Altman plot showed satisfying differences with the majority of outcomes (89 %) within 1 SD. Good to excellent intra- and moderate to good inter-observer correlations and a satisfying Bland-Altman plot when compared to 3D-CT show tendencies that MR-arthro is reliable and valid for measuring bony defects of the glenoid. (orig.)

  4. [Albert Reder Ritter von Schellmann (1826-1904)].

    Science.gov (United States)

    Schmidt, G; Holubar, K

    1990-01-01

    Albert Reder von Schellmann (1826-1904) was an important syphilidologist of the Vienna Medical School in the second half of the nineteenth century. He went in for the dualistic concept of the origin of syphilis and ulcer caused by soft chancre. In 1870 - Reder became head of a third dermato-syphilidologic department in the "Josephinum" in Vienna, where military surgeons got their medical education. At the same time the two full professorships of dermatosyphilidology in the Vienna General Hospital were held by Ferdinand von Hebra (1816-1880) and Carl Ludwig Sigmund von Ilanor (1810-1883).

  5. Candida (Torulopsis glabrata) liver abscesses eight years after orthotopic liver transplantation.

    Science.gov (United States)

    Annunziata, G M; Blackstone, M; Hart, J; Piper, J; Baker, A L

    1997-04-01

    The authors report the case of a 48-year-old man in whom candida (Torulopsis glabrata) liver abscesses developed 8 years after liver transplantation. After a week of fever, computed tomography and Doppler ultrasonography showed several fluid-filled loculations in the left lobe of the liver and hepatic arterial stenosis. Aspirates from the abscesses contained T. glabrata organisms. This complication probably developed because hepatic arterial stenosis resulted in bile infarcts (bilomas), which were contaminated via the biliary tract with candida from the biliary-enteric anastomosis. Catheter drainage and administration of amphotericin B for 10 weeks permitted successful retransplantation. T. glabrata liver abscesses, a life threatening complication that can occur long after liver transplantation, can be successfully managed by aggressive medical treatment followed by retransplantation.

  6. Castleman disease of the neck: CT and MR imaging findings

    International Nuclear Information System (INIS)

    Jiang, Xin-hua; Song, Hao-ming; Liu, Qing-yu; Cao, Yun; Li, Guo-hong; Zhang, Wei-dong

    2014-01-01

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases

  7. Castleman disease of the neck: CT and MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xin-hua [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Song, Hao-ming [Department of Cardiology, Shanghai Tongji Hospital, Shanghai 200065 (China); Liu, Qing-yu [Department of Radiology, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Cao, Yun [Department of Pathology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Li, Guo-hong [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China); Zhang, Wei-dong, E-mail: dongw.z@163.com [Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong 510060 (China)

    2014-11-15

    Objective: To characterize the computed tomography (CT) and magnetic resonance imaging (MRI) findings of Castleman disease of the neck. Methods: The imaging findings of 21 patients with Castleman disease of the neck were reviewed retrospectively. Of the 21 patients, 16 underwent unenhanced and contrast-enhanced CT scans; 5 underwent unenhanced and contrast-enhanced MRI scans. Results: The unenhanced CT images showed isolated or multiple well-defined homogenous mild hypodensity lesions in fifteen cases, and a heterogeneous nodule with central areas of mild hypodensity in one case. Calcification was not observed in any of the patients. In five patients, MR T1-weighted images revealed well-defined, homogeneous isointense or mild hyperintense lesions to the muscle; T2-weighted images showed these as intermediate hyperintense. Sixteen cases showed intermediate to marked homogeneous enhancement on contrast-enhanced CT or MR T1-weighted images. Of the other five cases that underwent double-phase CT scans, four showed mild or intermediate heterogeneous enhancement at the arterial phase, and homogeneous intermediate or marked enhancement at the venous phase; the remaining case showed mild and intermediate ring-enhancement with a central non-enhanced area at the arterial and venous phases, respectively. Conclusion: Castleman disease of the neck can be characterized as solitary or multiple well-defined, mild hypodensity or homogeneous intense lesions on plain CT/MR scans, and demonstrates intermediate and marked enhancement on contrast-enhanced CT/MR scans. On double-phase CT scans, Castleman disease often demonstrates mild enhancement at the arterial phase, and gradually uniform enhancement at venous phase. Double-phase enhanced CT or MRI may help to differentiate Castleman disease from other diseases.

  8. PREOPERATIVE COMPUTED TOMOGRAPHY VOLUMETRY AND GRAFT WEIGHT ESTIMATION IN ADULT LIVING DONOR LIVER TRANSPLANTATION.

    Science.gov (United States)

    Pinheiro, Rafael S; Cruz, Ruy J; Andraus, Wellington; Ducatti, Liliana; Martino, Rodrigo B; Nacif, Lucas S; Rocha-Santos, Vinicius; Arantes, Rubens M; Lai, Quirino; Ibuki, Felicia S; Rocha, Manoel S; D Albuquerque, Luiz A C

    2017-01-01

    Computed tomography volumetry (CTV) is a useful tool for predicting graft weights (GW) for living donor liver transplantation (LDLT). Few studies have examined the correlation between CTV and GW in normal liver parenchyma. To analyze the correlation between CTV and GW in an adult LDLT population and provide a systematic review of the existing mathematical models to calculate partial liver graft weight. Between January 2009 and January 2013, 28 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. All grafts were perfused with HTK solution. Estimated graft volume was estimated by CTV and these values were compared to the actual graft weight, which was measured after liver harvesting and perfusion. Median actual GW was 782.5 g, averaged 791.43±136 g and ranged from 520-1185 g. Median estimated graft volume was 927.5 ml, averaged 944.86±200.74 ml and ranged from 600-1477 ml. Linear regression of estimated graft volume and actual GW was significantly linear (GW=0.82 estimated graft volume, r2=0.98, slope=0.47, standard deviation of 0.024 and ppeso do enxerto (PE) para o transplante hepático com doador vivo (TFDV). Poucos estudos examinaram a correlação entre o VTC e PE no parênquima hepático normal. Analisar a correlação entre VTC e PE em uma população adulta de doadores para o TFDV e realização de revisão sistemática dos modelos matemáticos existentes para calcular o peso de enxertos hepáticos parciais. Foram revisados retrospectivamente 28 doadores consecutivos submetidos à hepatectomia direita para o TFDV entre janeiro de 2009 a janeiro de 2013. Todos os doadores eram adultos saudáveis ​​com VTC pré-operatório. Os enxertos foram perfundidos com solução de preservação HTK. O volume estimado foi obtido por VTC e estes valores foram comparados com o peso real do enxerto, o qual foi aferido depois da hepatectomia e perfusão do enxerto. A mediana do PE real foi de 782,5 g, média de 791,43±136 g, variando

  9. Das Geschäftsmodell von Retail Banken im Wandel der Digitalisierung

    OpenAIRE

    Messikommer, Cédric

    2016-01-01

    Der Prozess der Digitalisierung führt in unterschiedlichen Branchen zu tiefgreifenden Veränderungen. Dazu gehört auch der Finanzsektor, dessen Umfeld von erodierenden Margen und Tiefstzinsen geprägt ist. Die Digitalisierung hat weitreichende Auswirkungen auf die Geschäftsmodelle von Banken und speziell von Retail Banken. Deren Basisdienstleistungen werden zunehmend von neuen Mitbewerbern mit modernster Internet-Technologie angeboten. Damit sind wesentliche Teile der Wertschöpfungskette von Re...

  10. The need for company information manuals - Benefits of industry-wide standard solutions; Notwendigkeit von Betriebshandbuechern - Vorteile von Branchen-Standardloesungen

    Energy Technology Data Exchange (ETDEWEB)

    Sporleder, R.; Winter, G. [Stadtwerke Rostock AG (Germany)

    2000-07-01

    The paper explains the need for and the usefulness of company information manuals for companies of the energy sector. (orig./CB) [German] Im folgenden wird anhand von Kernsaetzen die Notwendigkeit von Betriebshandbuechern begruendet. Es wird offensichtlich, dass Geschaeftsfuehrungen von sicherheitsrelevanten Unternehmen wohlberaten sind, die in verschiedenen Vorschriften geforderte betriebliche Umsetzung des Inhalts dieser Vorschriften auf die firmeninternen Organisationsstrukturen vorzunehmen. Diese Umsetzung hilft intern, die betrieblichen Verantwortlichkeiten festzulegen, Verfahrensablaeufe zu bestimmen und erhoeht im Schadensfall erheblich die Chance fuer die jeweilige Geschaeftsfuehrung, den strafrechtlichen Vorwurf des Organisationsverschuldens abzuwehren. (orig./CB)

  11. Ga-68 Somatostatin Receptor PET/CT in von Hippel-Lindau Disease

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong-Ryool; Min, Jung-Joon [Chonnam National Univ. Hwasun Hospital, Hwasun (Korea, Republic of); Kulkarui, Harshad; Carreras, Cecilia; Schalch, Georg; Baum, Richard P. [Nuclear Medicine and Center for PET/CT, Zentralk Bad Berka, Bad Verka (Germany)

    2012-06-15

    Von Hippel-Lindau (VHL) disease is a dominantly inherited familial cancer syndrome with a variety of benign and malignant tumors such as retinal and central nervous system hemangioblastomas, endolymphatic sac tumors, renalcysts and tumors, pancreatic cysts and tumors, pheochromo-cytomas, and epididymal cystadenomas. Cross-sectional mo-dalities (computed tomography and magnetic resonance imaging) as well as ultrasound play a major role in the initial evaluation and follow-up of the various manifestations of VHL disease. Ga-68-labeled somatostatin receptor analogs already have a significant role in the diagnosis, staging, and therapy management of neuroendocrine neoplasms and neural crest tumors. Herein, we report a case presenting a variety of malignancies in VHL and showing the usefulness of Ga-68 somatostatin receptor PET/CT as a one-stop-shop imaging modality in the management of VHL disease.

  12. Ga-68 Somatostatin Receptor PET/CT in von Hippel-Lindau Disease

    International Nuclear Information System (INIS)

    Oh, Jong-Ryool; Min, Jung-Joon; Kulkarui, Harshad; Carreras, Cecilia; Schalch, Georg; Baum, Richard P.

    2012-01-01

    Von Hippel-Lindau (VHL) disease is a dominantly inherited familial cancer syndrome with a variety of benign and malignant tumors such as retinal and central nervous system hemangioblastomas, endolymphatic sac tumors, renalcysts and tumors, pancreatic cysts and tumors, pheochromo-cytomas, and epididymal cystadenomas. Cross-sectional mo-dalities (computed tomography and magnetic resonance imaging) as well as ultrasound play a major role in the initial evaluation and follow-up of the various manifestations of VHL disease. Ga-68-labeled somatostatin receptor analogs already have a significant role in the diagnosis, staging, and therapy management of neuroendocrine neoplasms and neural crest tumors. Herein, we report a case presenting a variety of malignancies in VHL and showing the usefulness of Ga-68 somatostatin receptor PET/CT as a one-stop-shop imaging modality in the management of VHL disease

  13. Die Rolle von RANK-Ligand und Osteoprotegerin bei Osteoporose

    Directory of Open Access Journals (Sweden)

    Hofbauer LC

    2004-01-01

    Full Text Available Receptor activator of nuclear factor (NF- κB ligand (RANKL, sein zellulärer Rezeptor RANK und der Decoy-Rezeptor Osteoprotegerin (OPG stellen ein essentielles Zytokinsystem für die Zellbiologie von Osteoklasten dar. Verschiedene Untersuchungen belegen die Bedeutung von Störungen des OPG/RANKL/RANK-Systems bei der Pathogenese metabolischer Knochenerkrankungen. In dieser Arbeit werden die wichtigsten Störungen des OPG/RANKL/RANK-Systems bei verschiedenen Osteoporoseformen dargestellt. Östrogenrezeptor- (ER- Agonisten wie 17 β-Östradiol, Raloxifen und Genistein stimulieren die osteoblastäre Produktion von OPG durch Aktivierung von ER- α in vitro, während Lymphozyten von Patientinnen mit Östrogenmangel RANKL überexprimieren. Die parenterale Gabe von OPG vermag den mit Östrogenmangel assoziierten Knochenverlust im Tiermodell und in einer kleineren klinischen Studie zu verhindern. Glukokortikoide und Immunsuppressiva steigern gleichzeitig die RANKL-Expression und hemmen die OPG-Produktion in osteoblastären Zellen in vitro. Glukokortikoide sind auch in vivo imstande, die OPG-Serumspiegel deutlich zu reduzieren. Dagegen hemmen biomechanische Reize in vitro die RANKL-Produktion und steigern die OPG-Produktion. Ein Fehlen dieser biomechanischen Reize bei längerer Immobilisierung kann daher den RANKL/OPG-Quotienten steigern, während die tierexperimentelle Immobilisierungs-Osteoporose durch die parenterale Gabe von OPG gemildert werden kann.

  14. Do carotid MR surface coils affect PET quantification in PET/MR imaging?

    International Nuclear Information System (INIS)

    Willemink, Martin J; Eldib, Mootaz; Leiner, Tim; Fayad, Zahi A; Mani, Venkatesh

    2015-01-01

    To evaluate the effect of surface coils for carotid MR imaging on PET quantification in a clinical simultaneous whole-body PET/MR scanner. A cylindrical phantom was filled with a homogeneous 2L water-FDG mixture at a starting dose of 301.2MBq. Clinical PET/MR and PET/CT systems were used to acquire PET-data without a coil (reference standard) and with two carotid MRI coils (Siemens Special Purpose 8-Channel and Machnet 4-Channel Phased Array). PET-signal attenuation was evaluated with Osirix using 51 (PET/MR) and 37 (PET/CT) circular ROIs. Mean and maximum standardized uptake values (SUVs) were quantified for each ROI. Furthermore, SUVs of PET/MR and PET/CT were compared. For validation, a patient was scanned with an injected dose of 407.7MBq on both a PET/CT and a PET/MR system without a coil and with both coils. PET/MR underestimations were -2.2% (Siemens) and -7.8% (Machnet) for SUVmean, and -1.2% (Siemens) and -3.3% (Machnet) for SUVmax, respectively. For PET/CT, underestimations were -1.3% (Siemens) and -1.4% (Machnet) for SUVmean and -0.5% (both Siemens and Machnet) for SUVmax, respectively using no coil data as reference. Except for PET/CT SUVmax values all differences were significant. SUVs differed significantly between PET/MR and PET/CT with SUVmean values of 0.51-0.55 for PET/MR and 0.68-0.69 for PET/CT, respectively. The patient examination showed that median SUVmean values measured in the carotid arteries decreased from 0.97 without a coil to 0.96 (Siemens) and 0.88 (Machnet). Carotid surface coils do affect attenuation correction in both PET/MR and PET/CT imaging. Furthermore, SUVs differed significantly between PET/MR and PET/CT.

  15. Graft-Versus-Host Disease after Liver Transplantation Complicated by Systemic Aspergillosis with Pancarditis

    Directory of Open Access Journals (Sweden)

    Joseph Romagnuolo

    2000-01-01

    Full Text Available Acute graft-versus-host disease (GVHD is a common complication after bone marrow transplantation, with characteristic rash and diarrhea being the most common features. After liver transplantation, however, this phenomenon is very rare. Most transplant patients are on a variety of medications, including immunosuppressants; therefore, the differential diagnosis of skin rash or diarrhea is broad. A 37-year-old man who underwent liver transplantation for primary biliary cirrhosis, and developed a rash and watery diarrhea, is presented. Skin and colonic biopsies confirmed acute GVHD. A pulse of intravenous steroids was given. The skin rash improved, but he developed pancytopenia. His course was complicated by central line infection, jugular and subclavian vein thrombosis, pseudomembranous colitis, recurrent bacteremia, cholestasis on total parenteral nutrition and cytomegalovirus infection. After the onset of pleuritic chest pain and clinical sepsis, spiral computed tomography scan of his chest and abdomen revealed septic infarcts in multiple organs. Despite empirical treatment with amphotericin B, he died of multiorgan dysfunction syndrome within 72 h. Autopsy revealed systemic aspergillosis with pancarditis, endocardial vegetations, and septic pulmonary, splenic, hepatic and renal infarcts. The pathogenesis and experience with this rare, but often fatal, complication of liver transplantation are reviewed. In contrast to GVHD after bone marrow transplantation, pancytopenia is common and liver dysfunction is rare. One should have a high level of suspicion in the liver transplant recipient presenting with rash and/or diarrhea.

  16. Various ocular MR imaging in a mouse implanted with a new cell line of retinoblastoma and the correlation with the pathology: preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hun; Kim, Il Joong; Yang, Jae Han; Byun, Joo Nam; Lee, Bong Jae [Chosun University, College of Medicine, Gwangju (Korea, Republic of); Kim, Jeong Hun; Yu, Young Suk [Seoul National University, College of Medicine, Seoul (Korea, Republic of)

    2007-05-15

    We wanted to show various MR and correlated pathologic images of retinoblastoma in nude mouse with a new human retinoblastoma cell line (SNUOT-Rb1), which was inoculated into the intravitreous cavity. The established cell line was inoculated into the intravitreous cavity of 36 eyeballs of 18 mice and the transplanted retinoblastoma was examined for 3 months. The T1-weighted (T1WI), T2-weighted (T2WI), and contrast enhanced (Gd-DTPA) T1-weighted images were obtained with using a small loop coil. After scanning, the mice's eyeballs were extracted and the hematoxylin and eosin stained specimens were examined with a microscope. We compared the MR imagings with pathologic findings and evaluated the character of the tumors. The innoculated cells in the eyeballs of the mice grew into retinoblastoma (23/36, 64%). The eyeballs with retinoblastoma protruded externally and showed focal hemorrhage. Most tumors showed iso-signal intensity on TIWI (13/23, 57%), high signal intensity on T2WI (17/23, 74%), and good enhancement (21/23, 91%) with contrast. Almost all of the tumors (n = 21) were located in the retina and three extraretinal tumors were confirmed by pathology. Involvement of the optic nerve was suspected on MRI and this was confirmed by pathology in 6 cases and 5 cases, respectively. We could demonstrate various MR imagings of transplanted retinoblastoma by using the new tumor cell line in vivo.

  17. Various ocular MR imaging in a mouse implanted with a new cell line of retinoblastoma and the correlation with the pathology: preliminary study

    International Nuclear Information System (INIS)

    Kim, Dong Hun; Kim, Il Joong; Yang, Jae Han; Byun, Joo Nam; Lee, Bong Jae; Kim, Jeong Hun; Yu, Young Suk

    2007-01-01

    We wanted to show various MR and correlated pathologic images of retinoblastoma in nude mouse with a new human retinoblastoma cell line (SNUOT-Rb1), which was inoculated into the intravitreous cavity. The established cell line was inoculated into the intravitreous cavity of 36 eyeballs of 18 mice and the transplanted retinoblastoma was examined for 3 months. The T1-weighted (T1WI), T2-weighted (T2WI), and contrast enhanced (Gd-DTPA) T1-weighted images were obtained with using a small loop coil. After scanning, the mice's eyeballs were extracted and the hematoxylin and eosin stained specimens were examined with a microscope. We compared the MR imagings with pathologic findings and evaluated the character of the tumors. The innoculated cells in the eyeballs of the mice grew into retinoblastoma (23/36, 64%). The eyeballs with retinoblastoma protruded externally and showed focal hemorrhage. Most tumors showed iso-signal intensity on TIWI (13/23, 57%), high signal intensity on T2WI (17/23, 74%), and good enhancement (21/23, 91%) with contrast. Almost all of the tumors (n = 21) were located in the retina and three extraretinal tumors were confirmed by pathology. Involvement of the optic nerve was suspected on MRI and this was confirmed by pathology in 6 cases and 5 cases, respectively. We could demonstrate various MR imagings of transplanted retinoblastoma by using the new tumor cell line in vivo

  18. Transplante de intestino delgado Small intestine transplantation

    Directory of Open Access Journals (Sweden)

    Flávio Henrique Ferreira Galvão

    2003-06-01

    Full Text Available RACIONAL: Avanços da biotecnologia e o desenvolvimento de novas drogas imunossupressoras melhoraram os resultados do transplante de intestino delgado. Esse transplante é atualmente indicado para casos especiais da falência intestinal. OBJETIVO: A presente revisão realça os recentes desenvolvimentos na área do transplante de intestino delgado. MATERIAL E MÉTODO: Mais de 600 publicações de transplante de intestino delgado foram revisadas. O desenvolvimento da pesquisa, novas estratégias de imunossupressão, monitorização do enxerto e do receptor, e avanços na técnica cirúrgica são discutidos. RESULTADOS: Realizaram-se cerca de 700 transplante de intestino delgado em 55 centros: 44% intestino-fígado, 41% enxerto intestinal isolado e 15% transplante multivisceral. Rejeição e infecção são as principais limitações desse transplante. Sobrevida de 5 anos na experiência internacional é de 46% para o transplante de intestino isolado, 43% para o intestino-fígado e de cerca de 30% para o transplante multivisceral. Sobrevidas prolongadas são mais freqüentes nos centros com maior experiência. Em série de 165 transplantes intestinais na Universidade de Pittsburgh, PA, EUA, foi relatada sobrevida do paciente maior do que 75% no primeiro ano, 54% em 5 anos e 42% em 10 anos. Mais de 90% desses pacientes assumem dieta oral irrestrita. CONCLUSÃO: O transplante de intestino delgado evoluiu de estratégia experimental para uma alternativa viável no tratamento da falência intestinal permanente. Promover o refinamento da terapia imunossupressora, do manejo e prevenção de infecções, da técnica cirúrgica e da indicação e seleção adequada dos pacientes é crucial para melhorar a sobrevida desse transplante.BACKGROUND: Significant progress has been made in clinical small bowel transplantation over the last decade mainly due advances in biotechnology and new immunosuppressive regiments. This transplantation has now been indicated

  19. Ascending colonic variceal bleeding: utility of phase-contrast MR portography in diagnosis and follow-up after treatment with TIPS and variceal embolization

    International Nuclear Information System (INIS)

    Chevallier, P.; Motamedi, J.P.; Oddo, F.; Padovani, B.; Demuth, N.; Caroli-Bosc, F.X.

    2000-01-01

    The authors describe the discovery of ascending colonic variceal veins via celiomesenteric diagnostic angiography following a bout of melena in a 44-year-old woman. Magnetic resonance imaging, including phase-contrast MR venography, allowed visualization of the portal and systemic veins immediately after the initial angiograms. The hemorrhagic episode did not resolve until after transjugular intrahepatic shunt insertion and selective variceal embolization through the shunt. At 1 week-, 3 months-, and 6 months post treatment, follow-up MR venography no longer revealed the presence of colonic varices. Colonoscopy at 6 months was normal and the patient did not have any further episodes of bleeding until a liver transplantation was performed after 9 months. (orig.)

  20. Attenuation correction for brain PET imaging using deep neural network based on dixon and ZTE MR images.

    Science.gov (United States)

    Gong, Kuang; Yang, Jaewon; Kim, Kyungsang; El Fakhri, Georges; Seo, Youngho; Li, Quanzheng

    2018-05-23

    Positron Emission Tomography (PET) is a functional imaging modality widely used in neuroscience studies. To obtain meaningful quantitative results from PET images, attenuation correction is necessary during image reconstruction. For PET/MR hybrid systems, PET attenuation is challenging as Magnetic Resonance (MR) images do not reflect attenuation coefficients directly. To address this issue, we present deep neural network methods to derive the continuous attenuation coefficients for brain PET imaging from MR images. With only Dixon MR images as the network input, the existing U-net structure was adopted and analysis using forty patient data sets shows it is superior than other Dixon based methods. When both Dixon and zero echo time (ZTE) images are available, we have proposed a modified U-net structure, named GroupU-net, to efficiently make use of both Dixon and ZTE information through group convolution modules when the network goes deeper. Quantitative analysis based on fourteen real patient data sets demonstrates that both network approaches can perform better than the standard methods, and the proposed network structure can further reduce the PET quantification error compared to the U-net structure. © 2018 Institute of Physics and Engineering in Medicine.