WorldWideScience

Sample records for transmission line pulse

  1. Coiled transmission line pulse generators

    Science.gov (United States)

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  2. Matching problems in pulse power radial transmission lines

    International Nuclear Information System (INIS)

    Mittag, K.; Brandelik, A.

    1984-12-01

    In this report we study the power transfer from a generator along a coaxial transmission line followed by a radial transmission line into a load, which in our application is a pseudo-spark plasma of about one millimeter diameter and about 15 cm in length. First the theoretical background based on transmission line theory is described. Then numerical results are presented. The main conclusion is that when matching the pulse power generator to the pseudo-spark plasma, the effect of the impedance transformation caused by the radial transmission line has to be taken into account. The conditions to obtain an optimal match are described. (orig.) [de

  3. On the Transmission Line Pulse Measurement Technique

    OpenAIRE

    X. Rodriguez; M. Eduardo; M. Harington

    2015-01-01

    Transmission Line Pulse is a short pulse (25ns to 150ns) measurement of the current-voltage (I/V) characteristics of the ESD protection built into an integrated circuit. The short TLP pulses are used to simulate the short ESD pulse threats and integrated circuit must tolerate without being damaged. In this work the fundamental principles of how the TLP pulse is generated and used to create I-V characteristic plots will be explored. The measurement will be then used to characterize the I-V cha...

  4. Novel pulse amplifying circuits based on transmission lines of different characteristic impedance

    International Nuclear Information System (INIS)

    Belloni, F.; Doria, D.; Lorusso, A.; Nassisi, V.

    2006-01-01

    Two novel circuits used to amplify electric pulses by the coupling of transmission lines of different characteristic impedance are described. The circuits are intended for doubling voltage pulses and for doubling current pulses. The former is composed by a R 0 transmission line closed on a set of two 2R 0 storage lines connected in parallel, while the latter is composed by a R 0 transmission line closed on a set of two R 0 /2 storage lines connected in series. The length of every storage line is half of input-pulse length. In both circuits, one storage line is characterized by an open extremity and the other line by a closed extremity. Connecting opportunely the storage lines to suitable load resistors, 4R 0 and R 0 /4, for the circuit having parallel and series connected lines, respectively, a twice of the output pulse intensity is obtained. Such devices are very suitable to generate high intensity voltage and/or current peaks which are very interesting in the field of the accelerators. Both circuit behaviours have been theoretically studied and verified by computer simulations

  5. PSPICE simulation of bipolar pulse converter based on short-circuited coaxial transmission line

    International Nuclear Information System (INIS)

    Shi Lei; Fan Yajun

    2010-01-01

    The operating principle of the bipolar pulse converter based on short-circuited coaxial transmission line type is given. The output bipolar pulses are simulated by using PSPICE program on condition of different electric length and different impedance of the short-circuited coaxial transmission line. The bipolar pulses are generated by using unipolar pulse with pulse width of 2 ns in experiment, the experimental result fit well with the simulation result. (authors)

  6. New schemes for high-voltage pulsed generators based on stepped transmission lines

    International Nuclear Information System (INIS)

    Bossamykin, V.S.; Gordeev, V.S.; Pavlovskii, A.I.

    1993-01-01

    Wave processes were analyzed from the point of effective energy delivery in pulsed power systems based on transmission lines. A series of new schemes for the pulsed generators based on multistage stepped transmission lines both with the capacitive and inductive energy storage was found. These devices can provide voltage or current transformation up to 5-10 times due to wave processes if stage's characteristic impedances are in a certain correlation. The schemes suggested can be widely applied in the new powerful pulsed power accelerators. The theoretical conclusions are justified experimentally

  7. Long-distance pulse propagation on high-frequency dissipative nonlinear transmission lines/resonant tunneling diode line cascaded maps

    International Nuclear Information System (INIS)

    Klofai, Yerima; Essimbi, B Z; Jaeger, D

    2011-01-01

    Pulse propagation on high-frequency dissipative nonlinear transmission lines (NLTLs)/resonant tunneling diode line cascaded maps is investigated for long-distance propagation of short pulses. Applying perturbative analysis, we show that the dynamics of each line is reduced to an expanded Korteweg-de Vries-Burgers equation. Moreover, it is found by computer experiments that the soliton developed in NLTLs experiences an exponential amplitude decay on the one hand and an exponential amplitude growth on the other. As a result, the behavior of a pulse in special electrical networks made of concatenated pieces of lines is closely similar to the transmission of information in optical/electrical communication systems.

  8. Long-distance pulse propagation on high-frequency dissipative nonlinear transmission lines/resonant tunneling diode line cascaded maps

    Energy Technology Data Exchange (ETDEWEB)

    Klofai, Yerima [Department of Physics, Higher Teacher Training College, University of Maroua, PO Box 46 Maroua (Cameroon); Essimbi, B Z [Department of Physics, Faculty of Science, University of Yaounde 1, PO Box 812 Yaounde (Cameroon); Jaeger, D, E-mail: bessimb@yahoo.fr [ZHO, Optoelectronik, Universitaet Duisburg-Essen, D-47048 Duisburg (Germany)

    2011-10-15

    Pulse propagation on high-frequency dissipative nonlinear transmission lines (NLTLs)/resonant tunneling diode line cascaded maps is investigated for long-distance propagation of short pulses. Applying perturbative analysis, we show that the dynamics of each line is reduced to an expanded Korteweg-de Vries-Burgers equation. Moreover, it is found by computer experiments that the soliton developed in NLTLs experiences an exponential amplitude decay on the one hand and an exponential amplitude growth on the other. As a result, the behavior of a pulse in special electrical networks made of concatenated pieces of lines is closely similar to the transmission of information in optical/electrical communication systems.

  9. A distributed parameter model of transmission line transformer for high voltage nanosecond pulse generation.

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Li, Longjie; He, Jiaxin; Li, Chenjie; Wang, Yifeng; Su, Can

    2017-09-01

    A transmission line transformer has potential advantages for nanosecond pulse generation including excellent frequency response and no leakage inductance. The wave propagation process in a secondary mode line is indispensable due to an obvious inside transient electromagnetic transition in this scenario. The equivalent model of the transmission line transformer is crucial for predicting the output waveform and evaluating the effects of magnetic cores on output performance. However, traditional lumped parameter models are not sufficient for nanosecond pulse generation due to the natural neglect of wave propagations in secondary mode lines based on a lumped parameter assumption. In this paper, a distributed parameter model of transmission line transformer was established to investigate wave propagation in the secondary mode line and its influential factors through theoretical analysis and experimental verification. The wave propagation discontinuity in the secondary mode line induced by magnetic cores is emphasized. Characteristics of the magnetic core under a nanosecond pulse were obtained by experiments. Distribution and formation of the secondary mode current were determined for revealing essential wave propagation processes in secondary mode lines. The output waveform and efficiency were found to be affected dramatically by wave propagation discontinuity in secondary mode lines induced by magnetic cores. The proposed distributed parameter model was proved more suitable for nanosecond pulse generation in aspects of secondary mode current, output efficiency, and output waveform. In depth, comprehension of underlying mechanisms and a broader view of the working principle of the transmission line transformer for nanosecond pulse generation can be obtained through this research.

  10. Parallel plate transmission line transformer

    NARCIS (Netherlands)

    Voeten, S.J.; Brussaard, G.J.H.; Pemen, A.J.M.

    2011-01-01

    A Transmission Line Transformer (TLT) can be used to transform high-voltage nanosecond pulses. These transformers rely on the fact that the length of the pulse is shorter than the transmission lines used. This allows connecting the transmission lines in parallel at the input and in series at the

  11. High temperature superconducting Josephson transmission lines for pulse and step sharpening

    International Nuclear Information System (INIS)

    Martens, J.S.; Wendt, J.R.; Hietala, V.M.; Ginley, D.S.; Ashby, C.I.H.; Plut, T.A.; Vawter, G.A.; Tigges, C.P.; Siegal, M.P.; Hou, S.Y.; Phillips, J.M.; Hohenwarter, G.K.G.

    1992-01-01

    An increasing number of high speed digital and other circuit applications require very narrow impulses or rapid pulse edge transitions. Shock wave transmission lines using series or shunt Josephson junctions are one way to generate these signals. Using two different high temperature superconducting Josephson junction processes (step-edge and electron beam defined nanobridges), such transmission lines have been constructed and tested at 77 K. Shock wave lines with approximately 60 YBaCuO nanobridges, have generated steps with fall times of about 10 ps. With step-edge junctions (with higher figures of merit but lower uniformity), step transition times have been reduced to an estimated 1 ps

  12. Multistage linear electron acceleration using pulsed transmission lines

    International Nuclear Information System (INIS)

    Miller, R.B.; Prestwich, K.R.; Poukey, J.W.; Epstein, B.G.; Freeman, J.R.; Sharpe, A.W.; Tucker, W.K.; Shope, S.L.

    1981-01-01

    A four-stage linear electron accelerator is described which uses pulsed radial transmission lines as the basic accelerating units. An annular electron beam produced by a foilless diode is guided through the accelerator by a strong axial magnetic field. Synchronous firing of the injector and the acccelerating modules is accomplished with self-breaking oil switches. The device has accelerated beam currents of 25 kA to kinetic energies of 9 MV, with 90% current transport efficiency. The average accelerating gradient is 3 MV/m

  13. Modeling particle emission and power flow in pulsed-power driven, nonuniform transmission lines

    Directory of Open Access Journals (Sweden)

    Nichelle Bruner

    2008-04-01

    Full Text Available Pulsed-power driven x-ray radiographic systems are being developed to operate at higher power in an effort to increase source brightness and penetration power. Essential to the design of these systems is a thorough understanding of electron power flow in the transmission line that couples the pulsed-power driver to the load. In this paper, analytic theory and fully relativistic particle-in-cell simulations are used to model power flow in several experimental transmission-line geometries fielded on Sandia National Laboratories’ upgraded Radiographic Integrated Test Stand [IEEE Trans. Plasma Sci. 28, 1653 (2000ITPSBD0093-381310.1109/27.901250]. Good agreement with measured electrical currents is demonstrated on a shot-by-shot basis for simulations which include detailed models accounting for space-charge-limited electron emission, surface heating, and stimulated particle emission. Resonant cavity modes related to the transmission-line impedance transitions are also shown to be excited by electron power flow. These modes can drive oscillations in the output power of the system, degrading radiographic resolution.

  14. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    OpenAIRE

    B. T. Hutsel; P. A. Corcoran; M. E. Cuneo; M. R. Gomez; M. H. Hess; D. D. Hinshelwood; C. A. Jennings; G. R. Laity; D. C. Lamppa; R. D. McBride; J. K. Moore; A. Myers; D. V. Rose; S. A. Slutz; W. A. Stygar

    2018-01-01

    We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-en...

  15. A novel structure of transmission line pulse transformer with mutually coupled windings.

    Science.gov (United States)

    Yu, Binxiong; Su, Jiancang; Li, Rui; Zhao, Liang; Zhang, Xibo; Wang, Junjie

    2014-03-01

    A novel structure of transmission line transformer (TLT) with mutually coupled windings is described in this paper. All transmission lines except the first stage of the transformer are wound on a common ferrite core for the TLT with this structure. A referral method was introduced to analyze the TLT with this structure, and an analytic expression of the step response was derived. It is shown that a TLT with this structure has a significantly slower droop rate than a TLT with other winding structures and the number of ferrite cores needed is largely reduced. A four-stage TLT with this structure was developed, whose input and output impedance were 4.2 Ω and 67.7 Ω, respectively. A frequency response test of the TLT was carried out. The test results showed that pulse response time of the TLT is several nanoseconds. The TLT described in this paper has the potential to be used as a rectangle pulse transformer with very fast response time.

  16. Optimized transmission-line impedance transformers for petawatt-class pulsed-power accelerators

    Directory of Open Access Journals (Sweden)

    D. R. Welch

    2008-03-01

    Full Text Available We have developed 1D analytic and 2D fully electromagnetic models of radial transmission-line impedance transformers. The models have been used to quantify the power-transport efficiency and pulse sharpening of such transformers as a function of voltage pulse width and impedance profile. For the cases considered, we find that in the limit as Γ→0 (where Γ is the ratio of the pulse width to the one-way transit time of the transformer, the transport efficiency is maximized when the impedance profile is exponential. As Γ increases from zero, the optimum profile gradually deviates from an exponential. A numerical procedure is presented that determines the optimum profile for a given pulse shape and width. The procedure can be applied to optimize the design of impedance transformers used in petawatt-class pulsed-power accelerators.

  17. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    Science.gov (United States)

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  18. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    Science.gov (United States)

    Hutsel, B. T.; Corcoran, P. A.; Cuneo, M. E.; Gomez, M. R.; Hess, M. H.; Hinshelwood, D. D.; Jennings, C. A.; Laity, G. R.; Lamppa, D. C.; McBride, R. D.; Moore, J. K.; Myers, A.; Rose, D. V.; Slutz, S. A.; Stygar, W. A.; Waisman, E. M.; Welch, D. R.; Whitney, B. A.

    2018-03-01

    We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-energy-storage capacitor, laser-triggered gas switch, pulse-forming line, self-break water switches, and tri-plate transmission lines. The circuit model also includes elements that represent Zs water convolute, vacuum insulator stack, four parallel outer magnetically insulated vacuum transmission lines (MITLs), double-post-hole vacuum convolute, inner vacuum MITL, and physics load. Within the vacuum-transmission-line system the model conducts analytic calculations of current loss. To calculate the loss, the model simulates the following processes: (i) electron emission from MITL cathode surfaces wherever an electric-field threshold has been exceeded; (ii) electron loss in the MITLs before magnetic insulation has been established; (iii) flow of electrons emitted by the outer-MITL cathodes after insulation has been established; (iv) closure of MITL anode-cathode (AK) gaps due to expansion of cathode plasma; (v) energy loss to MITL conductors operated at high lineal current densities; (vi) heating of MITL-anode surfaces due to conduction current and deposition of electron kinetic energy; (vii) negative-space-charge-enhanced ion emission from MITL anode surfaces wherever an anode-surface-temperature threshold has been exceeded; and (viii) closure of MITL AK gaps due to expansion of anode plasma. The circuit model is expected to be most accurate when the fractional current loss is small. We have performed circuit simulations of 52 Z experiments conducted with a variety of accelerator

  19. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    Directory of Open Access Journals (Sweden)

    B. T. Hutsel

    2018-03-01

    Full Text Available We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-energy-storage capacitor, laser-triggered gas switch, pulse-forming line, self-break water switches, and tri-plate transmission lines. The circuit model also includes elements that represent Zs water convolute, vacuum insulator stack, four parallel outer magnetically insulated vacuum transmission lines (MITLs, double-post-hole vacuum convolute, inner vacuum MITL, and physics load. Within the vacuum-transmission-line system the model conducts analytic calculations of current loss. To calculate the loss, the model simulates the following processes: (i electron emission from MITL cathode surfaces wherever an electric-field threshold has been exceeded; (ii electron loss in the MITLs before magnetic insulation has been established; (iii flow of electrons emitted by the outer-MITL cathodes after insulation has been established; (iv closure of MITL anode-cathode (AK gaps due to expansion of cathode plasma; (v energy loss to MITL conductors operated at high lineal current densities; (vi heating of MITL-anode surfaces due to conduction current and deposition of electron kinetic energy; (vii negative-space-charge-enhanced ion emission from MITL anode surfaces wherever an anode-surface-temperature threshold has been exceeded; and (viii closure of MITL AK gaps due to expansion of anode plasma. The circuit model is expected to be most accurate when the fractional current loss is small. We have performed circuit simulations of 52 Z experiments conducted with a

  20. Losses at magnetic nulls in pulsed-power transmission line systems

    International Nuclear Information System (INIS)

    Mendel, C.W. Jr.; Pointon, T.D.; Savage, M.E.; Seidel, D.B.; Magne, I.; Vezinet, R.

    2006-01-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds

  1. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    International Nuclear Information System (INIS)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-01-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO

  2. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang [College of Optoelectric Science and Engineering, National University of Defense Technology, Changsha 410073 (China)

    2014-05-15

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  3. A long-pulse repetitive operation magnetically insulated transmission line oscillator.

    Science.gov (United States)

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  4. Gyromagnetic nonlinear transmission line generator of high voltage pulses modulated at 4 GHz frequency with 1000 Hz pulse repetition rate

    International Nuclear Information System (INIS)

    Ulmasculov, M R; Sharypov, K A; Shunailov, S A; Shpak, V G; Yalandin, M I; Pedos, M S; Rukin, S N

    2017-01-01

    Results of testing of a generator based on a solid-state drive and the parallel gyromagnetic nonlinear transmission lines with external bias are presented. Stable rf-modulated high-voltage nanosecond pulses were shaped in each of the four channels in 1 s packets with 1000 Hz repetition frequencies. Pulse amplitude reaches -175 kV, at a modulation depth of rf-oscillations to 50 % and the effective frequency ∼4 GHz. (paper)

  5. Propagation of 1-THz bandwidth electrical pulses on high Tc superconducting transmission lines

    International Nuclear Information System (INIS)

    Nuss, M.C.; Mankiewich, P.M.; Howard, R.E.; Harvey, T.E.; Brandle, C.D.; Straugh, B.L.; Smith, P.R.

    1989-01-01

    The new high temperature superconductors have triggered enormous interest not only because of the unique physics involved but also because of their technical potentials, such as the promise for propagation of extremely short electrical pulses. Superconducting band caps of --20TH z are predicted assuming BCS theory for the superconductor, making lossless propagation of electrical pulses as short as 50 fs possible. Despite microwave measurements at low frequencies of several gigahertz first studies at higher frequencies by Dykaar et al have shown distortion-free propagation of 100-GHz electrical pulses on YBa 2 Cu 3 O 3 (YBCO) lines for --5-mm propagation distance. Results were also reported for aluminum coplanar lines and a YBCO ground plane. The authors report on the propagation of 1-ps electrical pulses (1-THz bandwidth) on YBCO coplanar transmission lines defined on lanthanum gallate (LaGaO 3 ) as a substrate. On LaGaO 3 , YBCO grows highly oriented as on SrTiO 3 . However, unlike SrTiO 3 , LaGaO 3 has a much lower dielectric constant and small losses in the terahertz frequency range. Electrical pulses of --750-fs duration are generated in a radiation-damaged silicon-on-sapphire photoconductive switch integrated into a 20-μm coplanar stripline with 10-μm spacing and excited with 100-fs optical pulses from a CPM laser. An μ1-THz bandwidth electrical contact is made to the YBCO coplanar stripline defined on LaGaO 3 using a flip-chip geometry. They find that electrical pulses broaden only from 750 fs to 1 ps with little loss in amplitude on traveling through their flip-chip input and propagated electrical pulses are probed by electooptic sampling in two small LiTaO 3 crystals separated by 3 mm

  6. Atlas transmission line/transition design and fabrication status

    CERN Document Server

    Ballard, E O; Davis, H A; Elizondo, J M; Gribble, R F; Nielsen, K E; Parker, G V; Ricketts, R L; Valdez, G A

    1999-01-01

    Atlas is a pulsed-power facility under development at Los Alamos National Laboratory to drive high-energy density experiments. Design has been completed for this new generation pulsed-power machine consisting of an azimuthal array of 24, 240-kV Marx modules and transmission lines supplying current to the load region at the machine center. The transmission line consists of a cable header, load protection switch, and tri-plate assembly interfacing to the center transition section. The cable header interface to the Marx module provides a mechanism to remove the Marx module for maintenance without removing other components of the transmission line. The load protection switch provides a mechanism for protecting the load during charging of the Marx in the event of a pre-fire condition. The aluminum tri-plate is a low-inductance transmission line that carries radial current flow from the Marx energy storage system at the machine periphery toward the load. All transmission line components are oil insulated except the...

  7. High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines.

    Science.gov (United States)

    Homma, Akira

    2011-07-01

    A novel annular parallel-strip transmission line was devised to construct high-voltage high-speed pulse isolation transformers. The transmission lines can easily realize stable high-voltage operation and good impedance matching between primary and secondary circuits. The time constant for the step response of the transformer was calculated by introducing a simple low-frequency equivalent circuit model. Results show that the relation between the time constant and low-cut-off frequency of the transformer conforms to the theory of the general first-order linear time-invariant system. Results also show that the test transformer composed of the new transmission lines can transmit about 600 ps rise time pulses across the dc potential difference of more than 150 kV with insertion loss of -2.5 dB. The measured effective time constant of 12 ns agreed exactly with the theoretically predicted value. For practical applications involving the delivery of synchronized trigger signals to a dc high-voltage electron gun station, the transformer described in this paper exhibited advantages over methods using fiber optic cables for the signal transfer system. This transformer has no jitter or breakdown problems that invariably occur in active circuit components.

  8. Simulation Analysis of Transmission-Line Impedance Transformers for Petawatt-Class Pulsed Power Accelerators

    International Nuclear Information System (INIS)

    Hu Yixiang; Qiu Aici; Sun Fengju; Huang Tao; Cong Peitian; Wang Liangping; Zeng Jiangtao; Li Yan; Zhang Xinjun; Lei Tianshi

    2011-01-01

    Based on the transmission line code TLCODE, a 1D circuit model for a transmission-line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to quantify the efficiencies of voltage-transport, energy-transport and power-transport for a transmission-line impedance transformer as functions of ψ (the ratio of the output impedance to the input impedance of the transformer) and Γ (the ratio of the pulse width to the one-way transit time of the transformer) under a large scale of m (the coefficient of the generalized exponential impedance profile). Simulation results suggest that with the increase in Γ, from 0 to ∞, the power transport efficiency first increases and then decreases. The maximum power transport efficiency can reach 90% or even higher for an exponential impedance profile (m = 1). With a consideration of dissipative loss in the dielectric and electrodes of the transformer, two representative designs of the water-insulated transformer are investigated for the next generation of petawatt-class z-pinch drivers. It is found that the dissipative losses in the electrodes are negligibly small, below 0.1%, but the dissipative loss in the water dielectric is about 1% to 4%. (fusion engineering)

  9. A hybrid pulse combining topology utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer.

    Science.gov (United States)

    Li, Jiangtao; Zhao, Zheng; Sun, Yi; Liu, Yuhao; Ren, Ziyuan; He, Jiaxin; Cao, Hui; Zheng, Minjun

    2017-03-01

    Numerous applications driven by pulsed voltage require pulses to be with high amplitude, high repetitive frequency, and narrow width, which could be satisfied by utilizing avalanche transistors. The output improvement is severely limited by power capacities of transistors. Pulse combining is an effective approach to increase the output amplitude while still adopting conventional pulse generating modules. However, there are drawbacks in traditional topologies including the saturation tendency of combining efficiency and waveform oscillation. In this paper, a hybrid pulse combining topology was adopted utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer. The factors affecting the combining efficiency were determined including the output time synchronization of Marx circuits, and the quantity and position of magnetic cores. The numbers of the parallel modules and the stages were determined by the output characteristics of each combining method. Experimental results illustrated the ability of generating pulses with 2-14 kV amplitude, 7-11 ns width, and a maximum 10 kHz repetitive rate on a matched 50-300 Ω resistive load. The hybrid topology would be a convinced pulse combining method for similar nanosecond pulse generators based on the solid-state switches.

  10. Effect of kicker circuit inductance on the transmission-line discharging

    International Nuclear Information System (INIS)

    Feng Deren; Wang Xiangqi; Shang Lei; Pei Yuanji; Fan Kuanjun

    2004-01-01

    Circuit inductance exists at discharging circuit of transmission-line, it includes the inductance at the main switch of thyratron when conducts, the linking inductance between the linking cables, the matching resistance inductance and the load inductance. When a long pulse is generated by transmission-line, the circuit inductance can be omitted. However, when the pulse is short (such as shorter than 200 ns), especially when ferromagnetic core kicker acts as the load, the effect is obvious. The short pulse current is needed in order to generate long time interval synchronous radiation light pulses by using online assembly of pulse convex orbit and DC convex orbit. This paper analyses the effect and presents several experimental results. It also supposes two practical cases to decrease the rise time of the pulse

  11. Circuit simulation of exponential transmission line for petawatt Z-pinch plasma drivers

    International Nuclear Information System (INIS)

    Zeng Zhengzhong

    2011-01-01

    It was demonstrated, based on the PSPICE circuit simulation, that the sectioning number for the circuit simulation of an exponential transmission line should be determined as twice the line's one-way electromagnetic wave transport time(electric length) divided by the wave-front of input pulse, owing to elimination of the wave reflections caused by artificial impedance discontinuity in the line's circuit simulation model, which employs a serial and sectional transmission line with impedances constant in each section but stair-step-varied between sections, and with total electric length the same as that of the exponential line under simulation. A pulse of 112.2 ns wave-front propagates through an exponential water transmission line of 1 234.2 ns one-way transport time will give the best sectioning number of 22, when the constant impedance of each section is given by the geometric mean of the two ends' impedances of the corresponding section on the exponential line under simulation. This sectioning rule is equivalent to the statement that the two-way transport time of each section should be equal to the input pulse's wave-front. (authors)

  12. Analysis of behaviour of overhead telecommunications or electric lines illuminated by a nuclear electromagnetic pulse: limitations of use for the transmission line theory

    International Nuclear Information System (INIS)

    Scotto, M.; Jecko, B.

    1987-01-01

    The illumination of overhead lines by a nuclear electromagnetic pulse (NEMP) in presence of a perfectly conducting ground gives rise to a scattering problem leading to phenomena both studied here in time and frequency domains. This problem is resolved with the help of an integral equation established in space-time domain and making possible (without approximation) the determination of the time dependence of the current induced on each point of the wire structure. Moreover, the passage in frequency domain allows to express a transfer function defined in one point of the excited line, pointing out its spectral characteristics. Results clearly show the insufficiency of the classic transmission line theory concealing some phenomena which are described here and for which an interpretation is proposed [fr

  13. Terawatt power division and combination using self-magnetically insulated transmission lines

    International Nuclear Information System (INIS)

    Crow, J.T.; Peterson, G.D.

    1980-01-01

    Self-magnetically insulated transmission lines are necessary for the efficient transport of the terawatt pulses used in electron and ion accelerators. For some applications it is desirable to divide one transmission line into two, or to combine outputs of two or more lines into one, by means of self-magnetically insulated convolutes. Tests have been made on a coaxial-to-triaxial convolute in which connections between negative inner and outer lines are made by pins passing through holes in the intermediate positive conductor. Measurements in the 2 MV, 400 kA, 40 ns pulse Mite facility indicate virtually 100% current transport through the convolute and the ability to vary the division of current between the inner and outer lines of the triax by choice of inner line impedance. These measurements, and results obtained with this convolute connected to the ion diode for which it was designed, will be presented

  14. ANALYSIS AND SIMULATION OF MAIN MAGNET TRANSMISSION LINE EFFECT

    Energy Technology Data Exchange (ETDEWEB)

    ZHANG,W.; MARNERIS, I.; SANDBERG, J.

    2007-06-25

    A main magnet chain forms a pair of transmission lines. Pulse-reflection-caused voltage and current differentiation throughout the magnet chain can have adverse effect on main magnet field quality. This effect is associated with magnet system configuration, coupling efficiency, and parasitic parameters. A better understanding of this phenomenon will help us in new design and existing system upgrade. In this paper, we exam the transmission line effect due to different input functions as well as configuration, coupling, and other parameters.

  15. Magnetic insulation in triplate and coaxial vacuum transmission lines. Report PIFR-1009

    International Nuclear Information System (INIS)

    Di Capua, M.; Pellinen, D.G.

    1980-08-01

    An experimental investigation was made of magnetically insulated transmission lines for use in an electron beam fusion accelerator. The magnetically insulated vacuum transmission lines would transfer the power pulses from many modules to a single diode region or multiple diodes to generate currents on the order of 100 MA. This approach may allow present limits on power flow through dielectric vacuum interfaces to be overcome. We have investigated symmetric parallel plate (triplate) transmission lines with a wave impedance of 24 Ω and a spacing of 1.9 cm, and coaxial transmission lines (coax) with a wave impedance of 42 Ω and a spacing of 2.9 cm

  16. Studies on the transmission and processing of pulse-shaped signals from nuclear radiation detectors using methods of systems theory

    International Nuclear Information System (INIS)

    Spillekothen, H.G.

    2007-01-01

    Using methods of the systems theory of electronic communications and theoretical electrical science, this study describes the transmission of pulse-shaped signals from nuclear radiation detectors from the detector over ''electrically long lines'' (cables) to the output of the first pulse amplifier. The example of pulses from BF 3 -proportional counters shows, using the Fourier transformation, that pulses from radiation detectors contain a frequency spectrum ranging well above 10 8 Hz. If these pulses are transmitted to the first amplifier over a line length of several meters, the laws of the theory of transmission lines must be taken into account to avoid false signals caused by reflections. In the example, line equations are applied and the influence of the line and the terminating impedance is demonstrated. The influence of the frequency response ν(ω) and the phase response δ(ω) of the amplifier is also considered in the sample calculation. The methods presented make it possible to analyze and optimize the transmission and amplification of signals from radiation detectors. Close agreement emerges between empirically observed and calculated pulse shapes. (orig.)

  17. Self-limiting current for magnetically insulated coaxial vacuum transmission lines

    International Nuclear Information System (INIS)

    Bergeron, K.D.

    1976-11-01

    Existing cold fluid theories for magnetic insulation are analyzed and applied to the transmission line configuration. The relevance of these results to the propagating short pulse problem, and to DC operation, are discussed

  18. Microparticle-initiated losses in magnetically insulated transmission lines

    International Nuclear Information System (INIS)

    Gray, E.W.; Stinnett, R.W.

    1986-01-01

    The author's discuss the effects of high and hypervelocity microparticles in magnetically-insulated transmission lines (MITLs) and how they may be a possible source for ion production near the anode in early stages of the voltage pulse, and current carriers during and after the power pulse, resulting in power flow losses. Early losses in the voltage pulse, due to microparticles, are estimated to be approximately 0.3 mA/cm/sup 2/. Blistering of the electrode surface, thought to be due to H/sup -/ bombardment, was also observed and appears to be consistent with losses due to negative ions previously reported by one of the authors

  19. The detailed characteristics of positive corona current pulses in the line-to-plane electrodes

    Science.gov (United States)

    Xuebao, LI; Dayong, LI; Qian, ZHANG; Yinfei, LI; Xiang, CUI; Tiebing, LU

    2018-05-01

    The corona current pulses generated by corona discharge are the sources of the radio interference from transmission lines and the detailed characteristics of the corona current pulses from conductor should be investigated in order to reveal their generation mechanism. In this paper, the line-to-plane electrodes are designed to measure and analyze the characteristics of corona current pulses from positive corona discharges. The influences of inter-electrode gap and line diameters on the detail characteristics of corona current pulses, such as pulse amplitude, rise time, duration time and repetition frequency, are carefully analyzed. The obtained results show that the pulse amplitude and the repetition frequency increase with the diameter of line electrode when the electric fields on the surface of line electrodes are same. With the increase of inter-electrode gap, the pulse amplitude and the repetition frequency first decrease and then turn to be stable, while the rise time first increases and finally turns to be stable. The distributions of electric field and space charges under the line electrodes are calculated, and the influences of inter-electrode gap and line electrode diameter on the experimental results are qualitatively explained.

  20. Design of the ITER Electron Cyclotron Heating and Current Drive Waveguide Transmission Line

    Science.gov (United States)

    Bigelow, T. S.; Rasmussen, D. A.; Shapiro, M. A.; Sirigiri, J. R.; Temkin, R. J.; Grunloh, H.; Koliner, J.

    2007-11-01

    The ITER ECH transmission line system is designed to deliver the power, from twenty-four 1 MW 170 GHz gyrotrons and three 1 MW 127.5 GHz gyrotrons, to the equatorial and upper launchers. The performance requirements, initial design of components and layout between the gyrotrons and the launchers is underway. Similar 63.5 mm ID corrugated waveguide systems have been built and installed on several fusion experiments; however, none have operated at the high frequency and long-pulse required for ITER. Prototype components are being tested at low power to estimate ohmic and mode conversion losses. In order to develop and qualify the ITER components prior to procurement of the full set of 24 transmission lines, a 170 GHz high power test of a complete prototype transmission line is planned. Testing of the transmission line at 1-2 MW can be performed with a modest power (˜0.5 MW) tube with a low loss (10-20%) resonant ring configuration. A 140 GHz long pulse, 400 kW gyrotron will be used in the initial tests and a 170 GHz gyrotron will be used when it becomes available. Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the U.S. Dept. of Energy under contract DE-AC05-00OR22725.

  1. Unsplit bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A [Pleasanton, CA

    2011-05-24

    A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  2. Transmission line component testing for the ITER Ion Cyclotron Heating and Current Drive System

    Science.gov (United States)

    Goulding, Richard; Bell, G. L.; Deibele, C. E.; McCarthy, M. P.; Rasmussen, D. A.; Swain, D. W.; Barber, G. C.; Barbier, C. N.; Cambell, I. H.; Moon, R. L.; Pesavento, P. V.; Fredd, E.; Greenough, N.; Kung, C.

    2014-10-01

    High power RF testing is underway to evaluate transmission line components for the ITER Ion Cyclotron Heating and Current Drive System. The transmission line has a characteristic impedance Z0 = 50 Ω and a nominal outer diameter of 305 mm. It is specified to carry up to 6 MW at VSWR = 1.5 for 3600 s pulses, with transient voltages up to 40 kV. The transmission line is actively cooled, with turbulent gas flow (N2) used to transfer heat from the inner to outer conductor, which is water cooled. High voltage and high current testing of components has been performed using resonant lines generating steady state voltages of 35 kV and transient voltages up to 60 kV. A resonant ring, which has operated with circulating power of 6 MW for 1 hr pulses, is being used to test high power, low VSWR operation. Components tested to date include gas barriers, straight sections of various lengths, and 90 degree elbows. Designs tested include gas barriers fabricated from quartz and aluminum nitride, and transmission lines with quartz and alumina inner conductor supports. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  3. Bipolar pulse forming line

    Science.gov (United States)

    Rhodes, Mark A.

    2008-10-21

    A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  4. Programmable pulse sequence generator with multiple output lines

    Science.gov (United States)

    Drabczyk, Hubert

    2006-10-01

    This paper presents a novel concept of pulse sequence generator and its prototype as an electronic circuit testing laboratory tool. The generator has multiple output lines and is capable of using control data defining different pulse sequences to be given to the outputs. It is also possible to use different voltage levels in output signal and switch output lines for reading data from driven system. The pulse sequence generator can be used for runtime environment simulation, as hardware tester or auxiliary tool in new designs. Important design factors were to keep cost of the tool low and allow integration with other projects by using flexible architecture. The prototype was based on universal programmer with adjustable power supply, '51 microcontroller and Altera Cyclone chip. The generator communicates witch PC computer via RS232 port. Dedicated software was developed in the course of this project, to control the tool and data transmission. The prototype confirmed the possibility to create an inexpensive multipurpose laboratory tool for programming, testing and simulation of digital devices.

  5. Magnetic pulse sharpener and delay-line

    International Nuclear Information System (INIS)

    Li Jin; Dai Guangsen; Xia Liansheng

    2002-01-01

    This paper describes a method to achieve short rise time pulse which has been delayed with a delay-line and magnetic pulse sharpener. A delay-line and two shock-lines are designed to carry pulsed signal with a maximum voltage magnitude up to 80 kV. A pulse of High voltage with arise time of 48 ns at a level of 0.1%-0.9% were achieved, and the attenuation in the line is very small

  6. The Pulse Line Ion Accelerator Concept

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, Richard J.

    2006-02-15

    The Pulse Line Ion Accelerator concept was motivated by the desire for an inexpensive way to accelerate intense short pulse heavy ion beams to regimes of interest for studies of High Energy Density Physics and Warm Dense Matter. A pulse power driver applied at one end of a helical pulse line creates a traveling wave pulse that accelerates and axially confines the heavy ion beam pulse. Acceleration scenarios with constant parameter helical lines are described which result in output energies of a single stage much larger than the several hundred kilovolt peak voltages on the line, with a goal of 3-5 MeV/meter acceleration gradients. The concept might be described crudely as an ''air core'' induction linac where the PFN is integrated into the beam line so the accelerating voltage pulse can move along with the ions to get voltage multiplication.

  7. Magnetically insulated transmission line oscillator

    Science.gov (United States)

    Bacon, L.D.; Ballard, W.P.; Clark, M.C.; Marder, B.M.

    1987-05-19

    A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields are produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap. 11 figs.

  8. Series Transmission Line Transformer

    Science.gov (United States)

    Buckles, Robert A.; Booth, Rex; Yen, Boris T.

    2004-06-29

    A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

  9. MEMS-based transmission lines for microwave applications

    Science.gov (United States)

    Wu, Qun; Fu, Jiahui; Gu, Xuemai; Shi, Huajuan; Lee, Jongchul

    2003-04-01

    This paper mainly presents a briefly review for recent progress in MEMS-based transmission lines for use in microwave and millimeterwave range. MEMS-based transmission lines including different transmission line structure such as membrane-supported microstrip line microstrip line, coplanar microshield transmission line, LIGA micromachined planar transmission line, micromachined waveguides and coplanar waveguide are discussed. MEMS-based transmission lines are characterized by low propagation loss, wide operation frequency band, low dispersion and high quality factor, in addition, the fabrication is compatible with traditional processing of integrated circuits (IC"s). The emergence of MEMS-based transmission lines provided a solution for miniaturizing microwave system and monolithic microwave integrated circuits.

  10. Atlas transmission line breakdown analysis

    CERN Document Server

    Nielsen, K E; Ballard, E O; Elizondo, J M; Gribble, R F; McCuistian, B T; Parsons, W M

    1999-01-01

    The Atlas facility will use 24 radially converging, vertically oriented and tapered, oil insulated, triplate transmission lines between the Marx generators and the central load region. Among the requirements of the transmission lines are low inductance and high reliability. The inter-conductor gap is nominally 2 cm and the lines taper from a height of 1.75 m at the Marx end to 0.32 m at the output end. The aluminum conductors, held together by 20 insulating spacers, are assembled and inserted as a unit into radial oil-filled steel tanks. The negative, high-voltage, center conductor is 2.54-cm thick and the outer ground conductors are 1.59-cm thick. All 24 triplate transmission lines connect to a transition section at near 1 m radius that couples the transmission lines to a disk/conical solid- dielectric-insulated power flow channel transmission line terminating at the load. Peak operating voltage on the lines can be as high as 240 kV with an effective stress time of 0.8 mu s. Testing of small sections of the ...

  11. Transmission Line Security Monitor: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    John Svoboda

    2011-04-01

    The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.

  12. Survey of transmission line corridors. [Data on delays in transmission line construction

    Energy Technology Data Exchange (ETDEWEB)

    1979-01-05

    The intent of this study is to determine the extent of delays experienced in planning and constructing transmission lines in the continental United States. The reasons for the delays are identified for each line studied and their effect on the total electrical system is sought. Data was collected for 136 different lines either recently built or currently under study. Statistics were developed for each line in several categories and comparisons of lines delayed were made by company, area served and generation capacity. From the study presented here it was found that: right-of-way acquisition procedures including condemnation and easement negotiation practices delay more projects than local, state and federal regulatory requirements combined; load growth reductions particularly in the east have reduced the impact of regulatory delays; the south, southeast and southwestern areas of the country experience fewer delays in constructing transmission lines than the more populated states, and the cost for corridor delays was responded to for only 17 of the 142 projects surveyed. By far the most costly delay is the expense of condemning land for transmission right-of-way.

  13. Transmission line capital costs

    International Nuclear Information System (INIS)

    Hughes, K.R.; Brown, D.R.

    1995-05-01

    The displacement or deferral of conventional AC transmission line installation is a key benefit associated with several technologies being developed with the support of the U.S. Department of Energy's Office of Energy Management (OEM). Previous benefits assessments conducted within OEM have been based on significantly different assumptions for the average cost per mile of AC transmission line. In response to this uncertainty, an investigation of transmission line capital cost data was initiated. The objective of this study was to develop a database for preparing preliminary estimates of transmission line costs. An extensive search of potential data sources identified databases maintained by the Bonneville Power Administration (BPA) and the Western Area Power Administration (WAPA) as superior sources of transmission line cost data. The BPA and WAPA data were adjusted to a common basis and combined together. The composite database covers voltage levels from 13.8 to 765 W, with cost estimates for a given voltage level varying depending on conductor size, tower material type, tower frame type, and number of circuits. Reported transmission line costs vary significantly, even for a given voltage level. This can usually be explained by variation in the design factors noted above and variation in environmental and land (right-of-way) costs, which are extremely site-specific. Cost estimates prepared from the composite database were compared to cost data collected by the Federal Energy Regulatory Commission (FERC) for investor-owned utilities from across the United States. The comparison was hampered because the only design specifications included with the FERC data were voltage level and line length. Working within this limitation, the FERC data were not found to differ significantly from the composite database. Therefore, the composite database was judged to be a reasonable proxy for estimating national average costs

  14. Overview of The Pulse Line Ion Accelerator

    International Nuclear Information System (INIS)

    Briggs, R.J.; Bieniosek, F.M.; Coleman, J.E.; Eylon, S.; Henestroza, E.; Leitner, M.; Logan, B.G.; Reginato, L.L.; Roy, P.K.; Seidl, P.A.; Waldron, W.L.; Yu, S.S.; Barnard, J.J.; Caporaso, G.J.; Friedman, A.; Grote, D.P.; Nelson, S.D.

    2006-01-01

    An overview of the Pulse Line Ion Accelerator (PLIA) concept and its development is presented. In the PLIA concept a pulse power driver applied to one end of a helical pulse line creates a traveling wave pulse that accelerates and axially confines a heavy ion beam pulse The motivation for its development at the IFE-VNL is the acceleration of intense, short pulse, heavy ion beams to regimes of interest for studies of High Energy Density Physics and Warm Dense Matter. Acceleration scenarios with constant parameter helical lines are described which result in output energies of a single stage much larger than the several hundred kilovolt peak voltages on the line, with a goal of 3-5 MeV/meter acceleration gradients. The main attraction of the concept is the very low cost it promises. It might be described crudely as an ''air core'' induction linac where the pulse-forming network is integrated into the beam line so the accelerating voltage pulse can move along with the ions to get voltage multiplication

  15. Development of an x-ray klystron modulator with a pulse-forming line and magnetic switch

    International Nuclear Information System (INIS)

    Akemoto, M.; Takeda, S.

    1992-01-01

    A new type of klystron modulator has been developed for the Japan Linear Collider. It consists of a pulse-forming line (PFL), a pulse transformer and a magnetic switch. In order to realize a compact modulator, a triplate strip transmission line using deionized water as a dielectric was adapted. An Fe amorphous core was used for the magnetic switch and the pulse transformer to reduce the size and cost. A preliminary test has shown that an output pulse with a peak voltage of 550 kV, a pulse length (flat-top) of 440 ns and a rise time of 165 ns can be generated for a dummy load with an impedance of 412Ω. It was also experimentally confirmed that the power efficiency of the modulator is approximately 83%. (Author) 7 figs., 3 tabs., 2 refs

  16. VT Digital Line Graph Miscellaneous Transmission Lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of Miscellaineous Transmission Lines. Digital line graph (DLG) data are digital representations of cartographic...

  17. Transmission Line Series Compensation for Wind Energy Transmission

    International Nuclear Information System (INIS)

    Palanichamy, C; Wong, Y C

    2015-01-01

    Wind energy has demonstrated to be a clean, copious and absolutely renewable source of energy, and the large penetration of it into the power grid indicates that wind energy is considered an effective means of power generation, Transmission of wind energy from remote locations to load centers necessitates long transmission lines. Series compensation is a proven and economical transmission solution to address system power transfer strength, grid stability, and voltage profile issues of long transmission lines. In this paper, a programmable approach to determine the capacitive reactance of series capacitor and optimum location for its placement to achieve maximum power transfer gas been presented. The respective program with sample solutions has been provided for real-time applications. (paper)

  18. Response analysis on nonuniform transmission line

    Directory of Open Access Journals (Sweden)

    Cvetković Zlata

    2005-01-01

    Full Text Available Transients on a loss less exponential transmission line with a pure resistance load are presented in this paper. The approach is based on the two-port presentation of the transmission line. Using Picard-Carson's method the transmission line equations are solved. The relationship between source voltage and the load voltage in s-domain is derived. All the results are plotted using program package Mathematica 3.0.

  19. Schemes of high-power pulsed generators with inductive storages on stepped lines

    International Nuclear Information System (INIS)

    Gordeev, V.S.; Bossamykin, V.S.

    1996-01-01

    Some multistage pulse generator designs based on homogeneous transmission lines of equal electrical length T 0 with stepwise impedance changes are described. The energy is initially stored as magnetic field by all the generator stages, while it is also stored by some of them as electrical energy. Upon triggering the switch connecting the high-voltage electrode of charged lines to the grounded generator frame, both the magnetic and electrical energies would concentrate completely at the generator output due to wave effects. Ideally, for any number of stages, the resistive load connected in parallel to the current opening switch is where a square-shaped voltage pulse of 2T 0 width would be generated, whose peak value can be considerably higher than the generator charging voltage. (author). 1 fig., 5 refs

  20. Schemes of high-power pulsed generators with inductive storages on stepped lines

    Energy Technology Data Exchange (ETDEWEB)

    Gordeev, V S; Bossamykin, V S [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    Some multistage pulse generator designs based on homogeneous transmission lines of equal electrical length T{sub 0} with stepwise impedance changes are described. The energy is initially stored as magnetic field by all the generator stages, while it is also stored by some of them as electrical energy. Upon triggering the switch connecting the high-voltage electrode of charged lines to the grounded generator frame, both the magnetic and electrical energies would concentrate completely at the generator output due to wave effects. Ideally, for any number of stages, the resistive load connected in parallel to the current opening switch is where a square-shaped voltage pulse of 2T{sub 0} width would be generated, whose peak value can be considerably higher than the generator charging voltage. (author). 1 fig., 5 refs.

  1. Error statistics during the propagation of short optical pulses in a high-speed fibreoptic communication line

    International Nuclear Information System (INIS)

    Shapiro, E G

    2008-01-01

    Simple analytic expressions are derived to approximate the bit error rate for data transmission through fibreoptic communication lines. The propagation of optical pulses is directly numerically simulated. Analytic estimates are in good agreement with numerical calculations. (fibreoptic communication)

  2. Transmission of radioiodine through sampling lines

    International Nuclear Information System (INIS)

    Unrein, P.J.; Pelletier, C.A.; Cline, J.E.; Voilleque, P.G.

    1985-01-01

    An experimental program to measure radioiodine transmission through sampling lines is described. The transmission depends upon both deposition on and resuspension from the walls of the line. The deposition and resuspension processes are themselves controlled by the length, diameter, and material of the line and the conditions under which it is operated. The operating conditions under study are sampling flow rate, temperature and relative humidity. Measurement results have been interpreted in terms of a four-compartment model of radioiodine deposition and resuspension. The model is applied to each of twenty or more segments of the line. Experimental measurements of short-term transmission fractions and the deposition velocities derived from them are presented for six lines. Data on resuspension rates for the same lines were obtained and are also discussed

  3. Efficient design of multituned transmission line NMR probes: the electrical engineering approach.

    Science.gov (United States)

    Frydel, J A; Krzystyniak, M; Pienkowski, D; Pietrzak, M; de Sousa Amadeu, N; Ratajczyk, T; Idzik, K; Gutmann, T; Tietze, D; Voigt, S; Fenn, A; Limbach, H H; Buntkowsky, G

    2011-01-01

    Transmission line-based multi-channel solid state NMR probes have many advantages regarding the cost of construction, number of RF-channels, and achievable RF-power levels. Nevertheless, these probes are only rarely employed in solid state-NMR-labs, mainly owing to the difficult experimental determination of the necessary RF-parameters. Here, the efficient design of multi-channel solid state MAS-NMR probes employing transmission line theory and modern techniques of electrical engineering is presented. As technical realization a five-channel ((1)H, (31)P, (13)C, (2)H and (15)N) probe for operation at 7 Tesla is described. This very cost efficient design goal is a multi port single coil transmission line probe based on the design developed by Schaefer and McKay. The electrical performance of the probe is determined by measuring of Scattering matrix parameters (S-parameters) in particular input/output ports. These parameters are compared to the calculated parameters of the design employing the S-matrix formalism. It is shown that the S-matrix formalism provides an excellent tool for examination of transmission line probes and thus the tool for a rational design of these probes. On the other hand, the resulting design provides excellent electrical performance. From a point of view of Nuclear Magnetic Resonance (NMR), calibration spectra of particular ports (channels) are of great importance. The estimation of the π/2 pulses length for all five NMR channels is presented. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Conceptual design for transmission line inspection robot

    International Nuclear Information System (INIS)

    Jalal, M F Abdul; Sahari, K S Mohamed; Anuar, A; Arshad, A D Mohd; Idris, M S

    2013-01-01

    Power transmission line is used for power distribution purposes due to their cost effective measure compared to underlying cable. However, prolonged exposure to natural weather may cause fatigue stress to the lines as well as induce material failure. Therefore, periodical line inspection is considered uttermost important as a preventive measure to avoid power outage. However, transmission line inspection has always been a high risk and expensive work. Hazardous works that may harm operator as well as routine that requires precise handling can be performed by robots. Various types of robots have been designed and developed for line inspection but only perform well on a straight and continuous line. As these robots encounter an obstacle during the inspection, then the real problem in terms of robot stability and smooth operation arises. In this paper, conceptual design and evaluation for transmission line inspection robot is presented. The inspection robot mobile robot must be able to bypass or avoid obstacles as it travels along the power transmission line.

  5. Tailoring of electron flow current in magnetically insulated transmission lines

    Directory of Open Access Journals (Sweden)

    J. P. Martin

    2009-03-01

    Full Text Available It is desirable to optimize (minimizing both the inductance and electron flow the magnetically insulated vacuum sections of low impedance pulsed-power drivers. The goal of low inductance is understandable from basic efficiency arguments. The goal of low electron flow results from two observations: (1 flowing electrons generally do not deliver energy to (or even reach most loads, and thus constitute a loss mechanism; (2 energetic electrons deposited in a small area can cause anode damage and anode plasma formation. Low inductance and low electron flow are competing goals; an optimized system requires a balance of the two. While magnetically insulated systems are generally forgiving, there are times when optimization is crucial. For example, in large pulsed-power drivers used to energize high energy density physics loads, the electron flow as a fraction of total current is small, but that flow often reaches the anode in relatively small regions. If the anode temperature becomes high enough to desorb gas, the resulting plasma initiates a gap closure process that can impact system performance. Magnetic-pressure driven (z pinches and material equation of state loads behave like a fixed inductor for much of the drive pulse. It is clear that neither fixed gap nor constant-impedance transmission lines are optimal for driving inductive loads. This work shows a technique for developing the optimal impedance profile for the magnetically insulated section of a high-current driver. Particle-in-cell calculations are used to validate the impedance profiles developed in a radial disk magnetically insulated transmission line geometry. The input parameters are the spacing and location of the minimum gap, the effective load inductance, and the desired electron flow profile. The radial electron flow profiles from these simulations are in good agreement with theoretical predictions when driven at relatively high voltage (i.e., V≥2  MV.

  6. Assembly delay line pulse generators

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    Assembly of six of the ten delay line pulse generators that will power the ten kicker magnet modules. One modulator part contains two pulse generators. Capacitors, inductances, and voltage dividers are in the oil tank on the left. Triggered high-pressure spark gap switches are on the platforms on the right. High voltage pulse cables to the kicker magnet emerge under the spark gaps. In the centre background are the assembled master gaps.

  7. Transmission Line Adapted Analytical Power Charts Solution

    Science.gov (United States)

    Sakala, Japhet D.; Daka, James S. J.; Setlhaolo, Ditiro; Malichi, Alec Pulu

    2017-08-01

    The performance of a transmission line has been assessed over the years using power charts. These are graphical representations, drawn to scale, of the equations that describe the performance of transmission lines. Various quantities that describe the performance, such as sending end voltage, sending end power and compensation to give zero voltage regulation, may be deduced from the power charts. Usually required values are read off and then converted using the appropriate scales and known relationships. In this paper, the authors revisit this area of circle diagrams for transmission line performance. The work presented here formulates the mathematical model that analyses the transmission line performance from the power charts relationships and then uses them to calculate the transmission line performance. In this proposed approach, it is not necessary to draw the power charts for the solution. However the power charts may be drawn for the visual presentation. The method is based on applying derived equations and is simple to use since it does not require rigorous derivations.

  8. Petawatt pulsed-power accelerator

    Science.gov (United States)

    Stygar, William A.; Cuneo, Michael E.; Headley, Daniel I.; Ives, Harry C.; Ives, legal representative; Berry Cottrell; Leeper, Ramon J.; Mazarakis, Michael G.; Olson, Craig L.; Porter, John L.; Wagoner; Tim C.

    2010-03-16

    A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

  9. Long-pulse applications of pulse-forming lines for high-power linac application

    International Nuclear Information System (INIS)

    Hoeberling, R.F.; Tallerico, P.J.

    1981-01-01

    The ever present demands for high efficiency in the RF power stations for particle accelerators have caused increased interest in longer RF pulses (ten's of microseconds) for linacs such as the Pion Generator for Medical Irradiation (PIGMI) and Free Electron Laser (FEL). For either RF power station, a fundamental decision is whether to use a modulating anode/hard-tube driver or pulsed cathode/line-type pulser configuration. The choices in the extremes of low power for very long pulses or for very-high-power, short pulses are, respectively, a modulated anode/hard tube modulator and pulsed cathode/pulse forming line. However, the demarcation between these two extremes is not clearcut. The criteria (cost, flexibility performance, reliability, efficiency) that resulted in the RF station definition of these two specific systems will be described

  10. Optoelectronic line transmission an introduction to fibre optics

    CERN Document Server

    Tricker, Raymond L

    2013-01-01

    Optoelectronic Line Transmission: An Introduction to Fibre Optics presents a basic introduction as well as a background reference manual on fiber optic transmission. The book discusses the basic principles of optical line transmission; the advantages and disadvantages of optical fibers and optoelectronic signalling; the practical applications of optoelectronics; and the future of optoelectronics. The text also describes the theories of optical line transmission; fibers and cables for optical transmission; transmitters including light-emitting diodes and lasers; and receivers including photodi

  11. Experimental research on Ku-band magnetically insulated transmission line oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Tao; Zhang, Jiande; He, Juntao; Li, Zhiqiang; Ling, Junpu [College of Optoelectric Science and Engineering, National University of Defense Technology, Hunan 410073 (China)

    2015-10-15

    An improved Ku-band magnetically insulated transmission line oscillator is proposed and investigated experimentally. In the particle-in-cell simulation, the Ku-band MILO generates the microwave with a power of 1.62 GW and a frequency of 13 GHz at the input voltage of 474 kV. The device is fabricated based on the simulation results, and an experiment system is designed. In the preliminary experiments, output microwave with frequency of 13.02 GHz, power of 150 MW, and pulse width of 17 ns is generated, under the diode voltage of 450 kV. Analysis on the experiment results shows that plasma produced due to the large current hitting to the outside of the collection tank is the essential cause for the low amplitude of the microwave power and short pulse width.

  12. Progress on corrugated waveguide components suitable for ITER ECH&CD transmission lines

    Directory of Open Access Journals (Sweden)

    Murphy C.J.

    2012-09-01

    Full Text Available The 2 MW cw requirement for ITER EC transmission lines has led GA to design a number of new and modified components, namely power monitors and polarizers to meet this requirement. In addition, the ITER transmission lines may require sliding joints or bellows to accommodate the thermal expansion of the lines and/or vessel motion. The ex-vessel sections of the EC launchers require double seal waveguides, miter bends and possibly double seal sliding joints to assure tritium retention in this region. GA has developed designs for many of these components and some of them have already been tested at high power at the JAEA RF Test Stand. Thermal analyses of the standard GA power monitor miter bend show that our standard design is suitable for 1 MW cw operation when the H-field is in the plane of the miter bend. For 2 MW cw operation a modified design, which also requires H-plane orientation, has been developed and a prototype has been fabricated and is ready for testing. For long pulse/cw operation, a 2 MW calorimetric miter bend with thermally isolated mirror has been designed and a prototype has been fabricated. Since the mirror is thermally isolated, calorimetry on the mirror cooling water can provide a measure of absorbed power. Such a miter bend, when made in a double seal version, could be useful for monitoring total power at the end of an EC transmission line just before the in-vessel section of an EC launcher. A mode analyzer using an all metal water-cooled beam splitter is being developed for use in measuring in real time the HE11 and higher order mode content or total power in EC transmission lines. Such a high power diagnostic can be very useful in optimizing the alignment of the MOU output into a transmission line and in monitoring the HE11 mode purity at various locations in a transmission line. Prior to making a 63.5 mm 170 GHz version suitable for use on ITER, several prototype 31.75 mm 110 GHz versions have been fabricated and tested at

  13. Radio and line transmission 2

    CERN Document Server

    Roddy, Dermot

    2013-01-01

    Radio and Line Transmission, Volume 2 gives a detailed treatment of the subject as well as an introduction to additional advanced subject matter. Organized into 14 chapters, this book begins by explaining the radio wave propagation, signal frequencies, and bandwidth. Subsequent chapters describe the transmission lines and cables; the aerials; tuned and coupled circuits; bipolar transistor amplifiers; field-effect transistors and circuits; thermionic valve amplifiers; LC oscillators; the diode detectors and modulators; and the superheterodyne receiver. Other chapters explore noise and interfere

  14. An on-line identification device for coal and gangue based on dual-energy γ-ray transmission and microcontroller

    International Nuclear Information System (INIS)

    Chen Guojie; Zhu Xing

    2004-01-01

    The operating principle, hardware design, software design and stabled-spectrum method of on-line identification device for coal and gangue based on dual-energy γ-ray transmission and microcontroller are introduced. The integrated linear amplifier and integrated single channel pulse height analyzer are analyzed. The on-line identification device has advantages of small size, low cost as well stabilization. (authors)

  15. Microwave transmission-line impedance data

    CERN Document Server

    Gunston, M A R

    1996-01-01

    A compendium of data for computing the characteristic impedance of transmission lines based on physical dimensions. Covers both conventional structures and unusual geometries, including coaxial, eccentric and elliptic coaxial, twin-wire, wire-above-ground, microstrip and derivatives, stripline, slabline and trough line. Also details numerous configurations of coupled lines.

  16. VT Electric Transmission Line Corridors - corridor lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The ELTRN layer depicts electric transmission line corridors in Vermont. Various methods have been used to digitize features. The data layer...

  17. A program to calculate pulse transmission responses through transversely isotropic media

    Science.gov (United States)

    Li, Wei; Schmitt, Douglas R.; Zou, Changchun; Chen, Xiwei

    2018-05-01

    We provide a program (AOTI2D) to model responses of ultrasonic pulse transmission measurements through arbitrarily oriented transversely isotropic rocks. The program is built with the distributed point source method that treats the transducers as a series of point sources. The response of each point source is calculated according to the ray-tracing theory of elastic plane waves. The program could offer basic wave parameters including phase and group velocities, polarization, anisotropic reflection coefficients and directivity patterns, and model the wave fields, static wave beam, and the observed signals for pulse transmission measurements considering the material's elastic stiffnesses and orientations, sample dimensions, and the size and positions of the transmitters and the receivers. The program could be applied to exhibit the ultrasonic beam behaviors in anisotropic media, such as the skew and diffraction of ultrasonic beams, and analyze its effect on pulse transmission measurements. The program would be a useful tool to help design the experimental configuration and interpret the results of ultrasonic pulse transmission measurements through either isotropic or transversely isotropic rock samples.

  18. Two-Port Representation of a Linear Transmission Line in the Time Domain.

    Science.gov (United States)

    1980-01-01

    which is a rational function. To use the Prony procedure it is necessary to inverse transform the admittance functions. For the transmission line, most...impulse is a constant, the inverse transform of Y0(s) contains an impulse of value ._ Therefore, if we were to numerically inverse transform Yo(s), we...would remove this im- pulse and inverse transform Y-(S) Y (S) 1’LR+C~ (23) The prony procedure would then be applied to the result. Of course, an impulse

  19. Electric Power Transmission Lines

    Data.gov (United States)

    Department of Homeland Security — Transmission Lines are the system of structures, wires, insulators and associated hardware that carry electric energy from one point to another in an electric power...

  20. Mathematical Constraints on the Use of Transmission Line Models for Simulating Initial Breakdown Pulses in Lightning Discharges

    Science.gov (United States)

    da Silva, C. L.; Merrill, R. A.; Pasko, V. P.

    2015-12-01

    A significant portion of the in-cloud lightning development is observed as a series of initial breakdown pulses (IBPs) that are characterized by an abrupt change in the electric field at a remote sensor. Recent experimental and theoretical studies have attributed this process to the stepwise elongation of an initial lightning leader inside the thunderstorm [da Silva and Pasko, JGR, 120, 4989-5009, 2015, and references therein]. Attempts to visually observe these events are hampered due to the fact that clouds are opaque to optical radiation. Due to this reason, throughout the last decade, a number of researchers have used the so-called transmission line models (also commonly referred to as engineering models), widely employed for return stroke simulations, to simulate the waveshapes of IBPs, and also of narrow bipolar events. The transmission line (TL) model approach is to prescribe the source current dynamics in a certain manner to match the measured E-field change waveform, with the purpose of retrieving key information about the source, such as its height, peak current, size, speed of charge motion, etc. Although the TL matching method is not necessarily physics-driven, the estimated source characteristics can give insights on the dominant length- and time-scales, as well as, on the energetics of the source. This contributes to better understanding of the environment where the onset and early stages of lightning development takes place.In the present work, we use numerical modeling to constrain the number of source parameters that can be confidently inferred from the observed far-field IBP waveforms. We compare different modified TL models (i.e., with different attenuation behaviors) to show that they tend to produce similar waveforms in conditions where the channel is short. We also demonstrate that it is impossible to simultaneously retrieve the speed of source current propagation and channel length from an observed IBP waveform, in contrast to what has been

  1. Kansas Electric Transmission Lines

    Data.gov (United States)

    Kansas Data Access and Support Center — This data set is a digital representation of the EletcircTransmission lines for the State of Kansas as maintained by the Kansas Corporation Commission. Data is...

  2. Flat-top pulse generation based on a fiber Bragg grating in transmission.

    Science.gov (United States)

    Preciado, Miguel A; Muriel, Miguel A

    2009-03-15

    We propose and analyze a flat-top pulse generator based on a fiber Bragg grating (FBG) in transmission. As is shown in the examples, a uniform period FBG properly designed can exhibit a spectral response in transmission close to sinc function (in amplitude and phase) in a certain bandwidth, because of the logarithm Hilbert transform relations, which can be used to reshape a Gaussian-like input pulse into a flat-top pulse.

  3. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Science.gov (United States)

    2010-10-01

    ... pipe before it is installed. (b) Testing of repairs made by welding. Each repair made by welding in... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Testing of repairs. 192.719... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line is...

  4. Pulsed electron beam generation with fast repetitive double pulse system

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Surender Kumar; Deb, Pankaj; Shyam, Anurag, E-mail: surender80@gmail.com [Energetics and Electromagnetics Division, Bhabha Atomic Research Centre, Visakhapatnam (India); Sharma, Archana [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

  5. Simulation methods of nuclear electromagnetic pulse effects in integrated circuits

    International Nuclear Information System (INIS)

    Cheng Jili; Liu Yuan; En Yunfei; Fang Wenxiao; Wei Aixiang; Yang Yuanzhen

    2013-01-01

    In the paper the ways to compute the response of transmission line (TL) illuminated by electromagnetic pulse (EMP) were introduced firstly, which include finite-difference time-domain (FDTD) and trans-mission line matrix (TLM); then the feasibility of electromagnetic topology (EMT) in ICs nuclear electromagnetic pulse (NEMP) effect simulation was discussed; in the end, combined with the methods computing the response of TL, a new method of simulate the transmission line in IC illuminated by NEMP was put forward. (authors)

  6. Circuit QED with hybrid metamaterial transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Ruloff, Stefan; Taketani, Bruno; Wilhelm, Frank [Theoretical Physics, Universitaet des Saarlandes, Saarbruecken (Germany)

    2016-07-01

    We're working on the theory of metamaterials providing some interesting results. The negative refraction index causes an opposite orientation of the wave vector k and the Poynting vector S of the travelling waves. Hence the metamaterial has a falling dispersion relation ∂ω(k)/∂k < 0 implying that low frequencies correspond to short wavelengths. Metamaterials are simulated by left-handed transmission lines consisting of discrete arrays of series capacitors and parallel inductors to ground. Unusual physics arises when right-and left-handed transmission lines are coupled forming a hybrid metamaterial transmission line. E.g. if a qubit is placed in front of a hybrid metamaterial transmission line terminated in an open circuit, the spontaneous emission rate is weakened or unaffected depending on the transition frequency of the qubit. Some other research interests are the general analysis of metamaterial cavities and the mode structure of hybrid metamaterial cavities for QND readout of multi-qubit operators. Especially the precise answer to the question about the definition of the mode volume of a metamaterial cavity is one of our primary goals.

  7. ''SMILE'': A Self Magnetically Insulated Transmission LinE adder for the 8-stage RADLAC II accelerator

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Poukey, J.W.; Shope, S.L.; Frost, C.A.; Turman, B.N.; Ramirez, J.J.; Prestwich, K.R.; Pankuch, P.J.

    1991-01-01

    The RADLAC II Self Magnetically Insulated Transmission LinE ''SMILE'' is a coaxial wave guide structure that is composed of two regions: (a) a 9.5-m voltage adder and (b) a 3-m long extension section. The adder section provides for the addition of the input voltages from the individual water-dielectric pulse forming line feeds. The extension section isolates the adder from the magnetically immersed foilless diode electron source load and efficiently transports the pulsed power out from the deionized water tank of the device. The SMILE modification of the RADLAC II accelerator enabled us to produce high quality beams of up to 14 MV, 100 kA. The design and the experimental evaluation of SMILE will be presented and compared with numerical simulation predictions. 12 refs., 9 figs., 1 tab

  8. Pulsed Power for a Dynamic Transmission Electron Microscope

    Energy Technology Data Exchange (ETDEWEB)

    dehope, w j; browning, n; campbell, g; cook, e; king, w; lagrange, t; reed, b; stuart, b; Shuttlesworth, R; Pyke, B

    2009-06-25

    Lawrence Livermore National Laboratory (LLNL) has converted a commercial 200kV transmission electron microscope (TEM) into an ultrafast, nanoscale diagnostic tool for material science studies. The resulting Dynamic Transmission Electron Microscope (DTEM) has provided a unique tool for the study of material phase transitions, reaction front analyses, and other studies in the fields of chemistry, materials science, and biology. The TEM's thermionic electron emission source was replaced with a fast photocathode and a laser beam path was provided for ultraviolet surface illumination. The resulting photoelectron beam gives downstream images of 2 and 20 ns exposure times at 100 and 10 nm spatial resolution. A separate laser, used as a pump pulse, is used to heat, ignite, or shock samples while the photocathode electron pulses, carefully time-synchronized with the pump, function as probe in fast transient studies. The device functions in both imaging and diffraction modes. A laser upgrade is underway to make arbitrary cathode pulse trains of variable pulse width of 10-1000 ns. Along with a fast e-beam deflection scheme, a 'movie mode' capability will be added to this unique diagnostic tool. This talk will review conventional electron microscopy and its limitations, discuss the development and capabilities of DTEM, in particularly addressing the prime and pulsed power considerations in the design and fabrication of the DTEM, and conclude with the presentation of a deflector and solid-state pulser design for Movie-Mode DTEM.

  9. Pulsed Power for a Dynamic Transmission Electron Microscope

    International Nuclear Information System (INIS)

    DeHope, W.J.; Browning, N.; Campbell, G.; Cook, E.; King, W.; Lagrange, T.; Reed, B.; Stuart, B.; Shuttlesworth, R.; Pyke, B.

    2009-01-01

    Lawrence Livermore National Laboratory (LLNL) has converted a commercial 200kV transmission electron microscope (TEM) into an ultrafast, nanoscale diagnostic tool for material science studies. The resulting Dynamic Transmission Electron Microscope (DTEM) has provided a unique tool for the study of material phase transitions, reaction front analyses, and other studies in the fields of chemistry, materials science, and biology. The TEM's thermionic electron emission source was replaced with a fast photocathode and a laser beam path was provided for ultraviolet surface illumination. The resulting photoelectron beam gives downstream images of 2 and 20 ns exposure times at 100 and 10 nm spatial resolution. A separate laser, used as a pump pulse, is used to heat, ignite, or shock samples while the photocathode electron pulses, carefully time-synchronized with the pump, function as probe in fast transient studies. The device functions in both imaging and diffraction modes. A laser upgrade is underway to make arbitrary cathode pulse trains of variable pulse width of 10-1000 ns. Along with a fast e-beam deflection scheme, a 'movie mode' capability will be added to this unique diagnostic tool. This talk will review conventional electron microscopy and its limitations, discuss the development and capabilities of DTEM, in particularly addressing the prime and pulsed power considerations in the design and fabrication of the DTEM, and conclude with the presentation of a deflector and solid-state pulser design for Movie-Mode DTEM

  10. State Estimation-based Transmission line parameter identification

    Directory of Open Access Journals (Sweden)

    Fredy Andrés Olarte Dussán

    2010-01-01

    Full Text Available This article presents two state-estimation-based algorithms for identifying transmission line parameters. The identification technique used simultaneous state-parameter estimation on an artificial power system composed of several copies of the same transmission line, using measurements at different points in time. The first algorithm used active and reactive power measurements at both ends of the line. The second method used synchronised phasor voltage and current measurements at both ends. The algorithms were tested in simulated conditions on the 30-node IEEE test system. All line parameters for this system were estimated with errors below 1%.

  11. A system for long pulse REB generation

    International Nuclear Information System (INIS)

    Tsuzuki, Tetsuya; Hasegawa, Mitsuru; Narihara, Kazumichi; Tomita, Yukihiro; Kubo, Shin; Kobata, Tadasuke; Mohri, Akihiro.

    1987-02-01

    A high voltage pulse generator system producing intense relativistic electron beams (REB) (1.5 μs pulse width, 30 kA peak current, 1 MeV energy) was developed to the use of REB ring formation. The system consists of a Marx generator, a transmission line with plastics-water hybrid insulators and a magnetically insulated transmission line connected with a cathode. The system has been well operated more than twenty thousands shots without troubles. (author)

  12. High voltage transmission lines - what are the hazards

    International Nuclear Information System (INIS)

    Repacholi, M.H.

    1985-01-01

    With the increasing use of high voltage alternating current (HVAC) transmission lines there is a growing concern among the public about possible human health effects resulting from exposure to the electric fields associated with these lines. While there is no definitive evidence of such effects, mounting public fear and activism over hypothesized health risks is already causing delays in the licensing and constuction of major power transmission facilities, and is encouraging the formation of regulatory policy. This paper briefly reviews the concerns, biological effects data and standards for HVAC transmission lines

  13. Application of magnetically insulated transmission lines for high current, high voltage electron beam accelerators

    International Nuclear Information System (INIS)

    Shope, S.L.; Mazarakis, M.G.; Frost, C.A.; Poukey, J.W.; Turman, B.N.

    1993-01-01

    Self Magnetically Insulated Transmission Lines (MITL) adders have been used successfully in a number of Sandia accelerators such as HELIA, HERMES III, and SABRE. Most recently the authors used a MITL adder in the RADLAC/SMILE electron beam accelerator to produce high quality, small radius (r b < 2 cm), 11 to 15 MeV, 50 to 100-kA beams with a small transverse velocity v perpendicular/c = β perpendicular ≤ 0.1. In RADLAC/SMILE, a coaxial MITL passed through the eight, 2 MV vacuum envelopes. The MITL summed the voltages of all eight feeds to a single foilless diode. The experimental results are in good agreement with code simulations. The authors' success with the MITL technology led them to investigate the application to higher energy accelerator designs. They have a conceptual design for a cavity-fed MITL that sums the voltages from 100 identical, inductively-isolated cavities. Each cavity is a toroidal structure that is driven simultaneously by four 8-ohm pulse-forming lines, providing a 1-MV voltage pulse to each of the 100 cavities. The point design accelerator is 100 MV, 500 kA, with a 30-50-ns FWHM output pulse

  14. Application of Magnetically Insulated Transmission Lines for high current, high voltage electron beam accelerators

    International Nuclear Information System (INIS)

    Shope, S.L.; Mazarakis, M.G.; Frost, C.A.; Poukey, J.W.; Turman, B.N.

    1991-01-01

    Self Magnetically Insulated Transmission Lines (MITL) adders have been used successfully in a number of Sandia accelerators such as HELIA, HERMES III, and SABRE. Most recently we used at MITL adder in the RADLAC/SMILE electron beam accelerator to produce high quality, small radius (r ρ < 2 cm), 11 to 15 MeV, 50 to 100-kA beams with a small transverse velocity v perpendicular/c = β perpendicular ≤ 0.1. In RADLAC/SMILE, a coaxial MITL passed through the eight, 2 MV vacuum envelopes. The MITL summed the voltages of all eight feeds to a single foilless diode. The experimental results are in good agreement with code simulations. Our success with the MITL technology led us to investigate the application to higher energy accelerator designs. We have a conceptual design for a cavity-fed MITL that sums the voltages from 100 identical, inductively-isolated cavities. Each cavity is a toroidal structure that is driven simultaneously by four 8-ohm pulse-forming lines, providing a 1-MV voltage pulse to each of the 100 cavities. The point design accelerator is 100 MV, 500 kA, with a 30--50 ns FWHM output pulse. 10 refs

  15. Application of magnetically insulated transmission lines for high current, high voltage electron beam accelerators

    Science.gov (United States)

    Shope, S. L.; Mazarakis, M. G.; Frost, C. A.; Poukey, J. W.; Turman, B. N.

    Self Magnetically Insulated Transmission Lines (MITL) adders were used successfully in a number of Sandia accelerators such as HELIA, HERMES III, and SABRE. Most recently we used at MITL adder in the RADLAC/SMILE electron beam accelerator to produce high quality, small radius (r(sub rho) less than 2 cm), 11 - 15 MeV, 50 - 100-kA beams with a small transverse velocity v(perpendicular)/c = beta(perpendicular) less than or equal to 0.1. In RADLAC/SMILE, a coaxial MITL passed through the eight, 2 MV vacuum envelopes. The MITL summed the voltages of all eight feeds to a single foilless diode. The experimental results are in good agreement with code simulations. Our success with the MITL technology led us to investigate the application to higher energy accelerator designs. We have a conceptual design for a cavity-fed MITL that sums the voltages from 100 identical, inductively-isolated cavities. Each cavity is a toroidal structure that is driven simultaneously by four 8-ohm pulse-forming lines, providing a 1-MV voltage pulse to each of the 100 cavities. The point design accelerator is 100 MV, 500 kA, with a 30 - 50 ns FWHM output pulse.

  16. Power electron beam front shortening in magnetically insulated transmission line with inner coaxial dielectric insert

    International Nuclear Information System (INIS)

    Galstjan, E.A.; Kazanskiy, L.N.

    1995-01-01

    By now the technology of high-power high-current relativistic electron beams with microsecond duration has been developed. The same technology is used in high-power electric pulse generation. However at present the high-power beams of subnanosecond duration are necessary for some investigations and applications. The maximum power parameter achieved by means of the usual technology is limited by a value in the range of 100-300 MW. For this reason a search for new ways to generate high-power REB (relativistic electron beam) is a topical problem. It is obvious that this problem may be reduced to the generation of pulses with a subnanosecond front duration. There are many methods to shorten a pulse duration to its front duration for instance, by using parts of short-circuited transmission lines

  17. Recent TWOQUICK particle simulations of one- and two- stage transmission lines and diodes on PBFA and SABRE

    International Nuclear Information System (INIS)

    Poukey, J.W.; Cuneo, M.E.; Lockner, T.R.

    1993-01-01

    This paper presents recent particle simulation studies of the pulsed-power machines PBFA and SABRE. The code used is the 2-D electromagnetic TWOQUICK. For SABRE we emphasize the single-stage case and compare with experiment. Here the voltage adder, magnetically-insulated-transmission-line (MITL), and proton applied-B extraction diode are all included in the fully time-dependent simulations. Results include vacuum wave precursor effects vs. cathode turn-on threshold, and the sheath-retrapping benefits of diode undermatching. For PBFA we emphasize the 2-stage case and compare with experiments using lithium ions. Here we include the transmission lines and MITLs feeding the 2-stage barrel diode. Results show that good operation is critically dependent on careful B-field shaping in the feeds and diode

  18. Bottlenecks reduction using superconductors in high voltage transmission lines

    Directory of Open Access Journals (Sweden)

    Daloub Labib

    2016-01-01

    Full Text Available Energy flow bottlenecks in high voltage transmission lines known as congestions are one of the challenges facing power utilities in fast developing countries. Bottlenecks occur in selected power lines when transmission systems are operated at or beyond their transfer limits. In these cases, congestions result in preventing new power supply contracts, infeasibility in existing contracts, price spike and market power abuse. The “Superconductor Technology” in electric power transmission cables has been used as a solution to solve the problem of bottlenecks in energy transmission at high voltage underground cables and overhead lines. The increase in demand on power generation and transmission happening due to fast development and linked to the intensive usage of transmission network in certain points, which in turn, lead to often frequent congestion in getting the required power across to where it is needed. In this paper, a bottleneck in high voltage double overhead transmission line with Aluminum Conductor Steel Reinforced was modeled using conductor parameters and replaced by Gap-Type Superconductor to assess the benefit of upgrading to higher temperature superconductor and obtain higher current carrying capacity. This proved to reduce the high loading of traditional aluminum conductors and allow more power transfer over the line using superconductor within the same existing right-of-way, steel towers, insulators and fittings, thus reducing the upgrade cost of building new lines.

  19. Ground-based transmission line conductor motion sensor

    International Nuclear Information System (INIS)

    Jacobs, M.L.; Milano, U.

    1988-01-01

    A ground-based-conductor motion-sensing apparatus is provided for remotely sensing movement of electric-power transmission lines, particularly as would occur during the wind-induced condition known as galloping. The apparatus is comprised of a motion sensor and signal-generating means which are placed underneath a transmission line and will sense changes in the electric field around the line due to excessive line motion. The detector then signals a remote station when a conditioning of galloping is sensed. The apparatus of the present invention is advantageous over the line-mounted sensors of the prior art in that it is easier and less hazardous to install. The system can also be modified so that a signal will only be given when particular conditions, such as specific temperature range, large-amplitude line motion, or excessive duration of the line motion, are occurring

  20. Transmission Line Resonator Segmented with Series Capacitors

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Boer, Vincent; Petersen, Esben Thade

    2016-01-01

    Transmission line resonators are often used as coils in high field MRI. Due to distributed nature of such resonators, coils based on them produce inhomogeneous field. This work investigates application of series capacitors to improve field homogeneity along the resonator. The equations for optimal...... values of evenly distributed capacitors are presented. The performances of the segmented resonator and a regular transmission line resonator are compared....

  1. Electromagnetic analysis using transmission line variables

    CERN Document Server

    Weiner, Maurice

    2010-01-01

    This book employs a relatively new method for solving electromagnetic problems, one which makes use of a transmission line matrix (TLM). The propagation space is imagined to be filled with this matrix. The propagating fields and physical properties are then mapped onto the matrix. Mathematically, the procedures are identical with the traditional numerical methods; however, the interpretation and physical appeal of the transmission line matrix are far superior. Any change in the matrix has an immediate physical significance. What is also very important is that the matrix becomes a launching pad

  2. Transmission line undergrounding : rate impact investigation and analysis

    International Nuclear Information System (INIS)

    2004-01-01

    In response to concerns expressed by the residents of Markham, Ontario regarding the possible environmental and health impacts of a proposed 230 kV overhead transmission line, Hydro One Networks Inc. (HONI) has proposed to place the line underground as an alternative. This analysis was prepared to evaluate the potential impacts on transmission rates and consumer prices related to changes in the level of underground construction of transmission lines by HONI, as opposed to overhead construction. The report presents the approach to data collection; cost estimates and projections; the modeling and projecting of HONI's regulated rate base and revenue requirement on a basis that reflects the manner in which its future transmission rates are expected to be established; estimates of the incremental cost of undergrounding reflecting a range of reasonable assumptions; and a comparison of the resulting transmission costs and total customer bill. To address the issue of potential demand in other municipalities for additional undergrounding, the study also examined the cumulative effects of ten years' incremental undergrounding costs (i.e. effects on 2014 rates). It was concluded that if HONI were to implement an undergrounding program beginning in 2005, resulting in the installation of 80 km of underground lines by 2014, and shared costs by all users of HONI's system through the network transmission charges, the 2014 transmission rates would be higher. 5 tabs

  3. Proposal and design of phase-modulated fiber gratings in transmission for pulse shaping.

    Science.gov (United States)

    Preciado, Miguel A; Shu, Xuewen; Sugden, Kate

    2013-01-01

    An approach to pulse shaping using a phase-modulated fiber Bragg grating (FBG) in transmission is proposed and designed. We show that phase-modulated FBGs can provide transmission responses suitable for pulse shaping applications, offering important technological feasibility benefits, since the coupling strength remains basically uniform in the grating. Moreover, this approach retains the substantial advantages of FBGs in transmission, such as optimum energy efficiency, no requirement for an optical circulator, and robustness against fabrication errors.

  4. Analysis of some coplanar transmission lines: coplanar coupled lines, coplanar coupled striplines, and coplanar coupled lines with rectangular microshield

    Science.gov (United States)

    Yuan, Naichang; He, Jianguo; Yao, Demiao; Dai, Qin; Lin, Weigan

    1995-06-01

    Two types of coplanar transmission lines, rectangular microshield coplanar coupled lines (RMCCL) and coplanar coupled rectangular microshield lines (CCRML), are proposed for MMIC applications. These are developed from coplanar coupled lines (CCL) and coplanar coupled strip lines (CCS). Analytic formulas are presented for calculating the quasistatic TEM parameters of these coupled lines by means of exact conformal mapping techniques. Numerical results are also presented to illustrate the properties of these coplanar transmission lines.

  5. Transmission-Line Readout with Good Time and Space Resolutions for Planacon MCP-PMTs

    CERN Document Server

    Tang, F; Byrum, K; Drake, G; Ertley, C; Frisch, H; Genat, J-F; May, E

    2008-01-01

    With commercially-available multi-anode microchannel plate photomultiplier tubes (MCP-PMT) and electronics, resolutions significantly better than 10 psec have been achieved in small systems with a few readout channels[1,2]. For large-scale time-of-flight systems used in particle physics, which may cover tens of square meters, a solution must be found with a manageable number of electronics channels and low total power consumption on the readout electronics without degrading the system timing resolution. We present here the design of a transmission-line readout for a Photonis Planacon MCP-PMT that has these characteristics. The tube, which is 5 cm square, is characterized by signal pulse rise times in the order of 200 psec and transit time spreads (TTS) in the order of 25 psec[1, 2]. The model 85011-011 MCP has 1024 anode pads laid out in an array of 32 by 32 on the back of the tube. The proposed readout is implemented on a Rogers 4350B printed circuit board with 32 parallel 50-ohm transmission lines on 1.6 mm...

  6. A current controlled variable delay superconducting transmission line

    International Nuclear Information System (INIS)

    Anlage, S.M.; Snortland, H.J.; Beasley, M.R.

    1989-01-01

    The authors present a device concept for a current-controlled variable delay for superconducting transmission line. The device makes use of the change in kinetic inductance of a superconducting transmission line under the application of a DC bias current. The relevant materials parameters and several promising superconducting materials have been identified

  7. Self-Shielding Of Transmission Lines

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, Christos [Univ. of New Mexico, Albuquerque, NM (United States)

    2017-03-01

    The use of shielding to contend with noise or harmful EMI/EMR energy is not a new concept. An inevitable trade that must be made for shielding is physical space and weight. Space was often not as much of a painful design trade in older larger systems as they are in today’s smaller systems. Today we are packing in an exponentially growing number of functionality within the same or smaller volumes. As systems become smaller and space within systems become more restricted, the implementation of shielding becomes more problematic. Often, space that was used to design a more mechanically robust component must be used for shielding. As the system gets smaller and space is at more of a premium, the trades starts to result in defects, designs with inadequate margin in other performance areas, and designs that are sensitive to manufacturing variability. With these challenges in mind, it would be ideal to maximize attenuation of harmful fields as they inevitably couple onto transmission lines without the use of traditional shielding. Dr. Tom Van Doren proposed a design concept for transmission lines to a class of engineers while visiting New Mexico. This design concept works by maximizing Electric field (E) and Magnetic Field (H) field containment between operating transmission lines to achieve what he called “Self-Shielding”. By making the geometric centroid of the outgoing current coincident with the return current, maximum field containment is achieved. The reciprocal should be true as well, resulting in greater attenuation of incident fields. Figure’s 1(a)-1(b) are examples of designs where the current centroids are coincident. Coax cables are good examples of transmission lines with co-located centroids but they demonstrate excellent field attenuation for other reasons and can’t be used to test this design concept. Figure 1(b) is a flex circuit design that demonstrate the implementation of self-shielding vs a standard conductor layout.

  8. Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation

    International Nuclear Information System (INIS)

    Shin, Young Kil; Choi, Dong Myung

    2007-01-01

    By using numerical analysis methods, through transmission type pulsed eddy current (PEC) testing is modeled and PEC signal responses due to varying material conductivity, permeability, thickness, lift-off and pulse width are investigated. Results show that the peak amplitude of PEC signal gets reduced and the time to reach the peak amplitude is increased as the material conductivity, permeability, and specimen thickness increase. Also, they indicate that the pulse width needs to be shorter when evaluating the material conductivity and the plate thickness using the peak amplitude, and when the pulse width is long, the peak time is found to be more useful. Other results related to lift-off variation are reported as well

  9. Measurement-Based Transmission Line Parameter Estimation with Adaptive Data Selection Scheme

    DEFF Research Database (Denmark)

    Li, Changgang; Zhang, Yaping; Zhang, Hengxu

    2017-01-01

    Accurate parameters of transmission lines are critical for power system operation and control decision making. Transmission line parameter estimation based on measured data is an effective way to enhance the validity of the parameters. This paper proposes a multi-point transmission line parameter...

  10. Flux Cloning in Josephson Transmission Lines

    International Nuclear Information System (INIS)

    Gulevich, D.R.; Kusmartsev, F.V.

    2006-01-01

    We describe a novel effect related to the controlled birth of a single Josephson vortex. In this phenomenon, the vortex is created in a Josephson transmission line at a T-shaped junction. The 'baby' vortex arises at the moment when a 'mother' vortex propagating in the adjacent transmission line passes the T-shaped junction. In order to give birth to a new vortex, the mother vortex must have enough kinetic energy. Its motion can also be supported by an externally applied driving current. We determine the critical velocity and the critical driving current for the creation of the baby vortices and briefly discuss the potential applications of the found effect

  11. Precise ion optical description of strip-line pulsed magnetic lenses

    International Nuclear Information System (INIS)

    Varentsov, D.; Spiller, P.; Eickhoff, H.; Hoffmann, D.H.H.

    2002-01-01

    A specific computer code has been developed to investigate ion optical properties of a new generation of pulsed strip-line high current magnets. The code is based on a modern 'Differential Algebra' computational technique and it is able to calculate transfer matrices of pulsed strip-line magnets up to arbitrary order. The realistic three-dimensional distribution of the magnetic field in pulsed lenses as well as all the fringing field effects are taken into account in the simulations. We have demonstrated, that for precise description of such magnets one cannot use the existing ion optical codes where ideal multipole field distributions and fringing fields, typical for conventional iron-dominated magnets are assumed. The transfer matrix elements of pulsed strip-line lenses differ significantly from those of conventional magnets, especially in higher orders

  12. Risk Analysis Method Based on FMEA for Transmission Line in Lightning Hazards

    Directory of Open Access Journals (Sweden)

    You-Yuan WANG

    2014-05-01

    Full Text Available Failure rate of transmission line and reliability of power system are significantly affected by Lightning meteorological factor. In view of the complexity and variability of Lightning meteorological factors, this paper presents lightning trip-out rate model of transmission line in considering distribution of ground flash density and lightning day hours. Meanwhile, presents a failure rate model of transmission line in different condition, and a risk analysis method for transmission line considering multiple risk factors based on risk quantification. This method takes Lightning meteorological factor as the main evaluation standard, and establishes risk degree evaluation system for transmission line including another five evaluation standard. Put forward the risk indicators by quantify the risk factors based on experience date of transmission line in service. Based on the risk indexes comprehensive evaluation is conducted, and the evaluation result closer to practice is achieved, providing basis for transmission line risk warning and maintenance strategy. Through the risk analysis for 220 kV transmission line in a certain power supply bureau, the effectiveness of the proposed method is validated.

  13. Airplane Ice Detector Based on a Microwave Transmission Line

    Science.gov (United States)

    Ngo, Phong; Arndt, G. Dickey; Carl, James R.

    2004-01-01

    An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a

  14. Design of Chebychev’s Low Pass Filters Using Nonuniform Transmission Lines

    Directory of Open Access Journals (Sweden)

    Said Attamimi

    2016-03-01

    Full Text Available Transmission lines are utilized in many applications to convey energy as well as information. Nonuniform transmission lines (NTLs are obtained through variation of the characteristic quantities along the axial direction. Such NTLs can be used to design network elements, like matching circuits, delay equalizers, filters, VLSI interconnections, etc. In this work, NTLs were analyzed with a numerical method based on the implementation of method of moment. In order to approximate the voltage and current distribution along the transmission line, a sum of basis functions with unknown amplitudes was introduced. As basis function, a constant function was used. In this work, we observed several cases such as lossless and lossy uniform transmission lines with matching and arbitrary load. These cases verified the algorithm developed in this work. The second example consists of nonuniform transmission lines in the form of abruptly changing transmission lines. This structure was used to design a Chebychev’s low pass filter. The calculated reflection and transmission factors of the filters showed some coincidences with the measurements.

  15. Energy losses in magnetically insulated transmission lines due to microparticles

    International Nuclear Information System (INIS)

    Gray, E.W.; Stinnett, R.W.

    1987-01-01

    We discuss the effects of high-velocity and hypervelocity microparticles in the magnetically insulated transmission lines of multiterawatt accelerators used for particle beam fusion and radiation effects simulation. These microparticles may be a possible source for plasma production near the anode and cathode in early stages of the voltage pulse, and current carriers during and after the power pulse, resulting in power flow losses. Losses in the current pulse, due to microparticles, are estimated to be approximately 12 mA/cm 2 (0.3 kA) as a lower limit, and --0.3 A/cm 2 (7.2 kA) for microparticle initiated, anode plasma positive ion transport. We have calculated the velocities reached by these microparticles and the effects on them of Van der Waals forces. Field emission from the particles and their effects on cathode and anode plasma formation have been examined. Particle collision with the electrodes is also examined in terms of plasma production, as in the electron deposition in the particles in transit across the anode-cathode gap. Blistering of the electrode surface, thought to be due to H - bombardment was also observed and appears to be consistent with losses due to negative ions previously reported by J. P. VanDevender, R. W. Stinnett, and R. J. Anderson [App. Phys. Lett. 38, 229 (1981)

  16. PULSE SYNTHESIZING GENERATOR

    Science.gov (United States)

    Kerns, Q.A.

    1963-08-01

    >An electronlc circuit for synthesizing electrical current pulses having very fast rise times includes several sinewave generators tuned to progressively higher harmonic frequencies with signal amplitudes and phases selectable according to the Fourier series of the waveform that is to be synthesized. Phase control is provided by periodically triggering the generators at precisely controlled times. The outputs of the generators are combined in a coaxial transmission line. Any frequency-dependent delays that occur in the transmission line can be readily compensated for so that the desired signal wave shape is obtained at the output of the line. (AEC)

  17. High-explosive-driven delay line pulse generator

    International Nuclear Information System (INIS)

    Shearer, J.W.

    1982-01-01

    The inclusion of a delay line circuit into the design of a high-explosive-driven generator shortens the time constant of the output pulse. After a brief review of generator concepts and previously described pulse-shortening methods, a geometry is presented which incorporates delay line circuit techcniques into a coil generator. The circuit constants are adjusted to match the velocity of the generated electromagnetic wave to the detonation velocity of the high explosive. The proposed generator can be modeled by adding a variable inductance term to the telegrapher's equation. A particular solution of this equation is useful for exploring the operational parameters of the generator. The duration of the electromagnetic pulse equals the radial expansion time of the high-explosive-driven armature until it strikes the coil. Because the impedance of the generator is a constant, the current multiplication factor is limited only by nonlinear effects such as voltage breakdown, diffusion, and compression at high energies

  18. Research on the Test of Transmission Line Galloping

    Science.gov (United States)

    Zhang, Lichun; Li, Qing; lv, Zhongbin; Ji, Kunpeng; Liu, Bin

    2018-03-01

    The load of iced transmission line and the load generated by galloping after the conductor are covered by ice all may cause severe circuit faults, such as tripping, conductor breaking, armor clamp damage and even tower collapse, thus severely threatening running safety of power system. The generation and development processes of galloping of power transmission line is very complicated, and numerous factors may influence the galloping excitation, such as environmental factors, terrain factors and structural parameters of power transmission line; in which, the ice covering of conductor is one of necessary factors causing galloping. Therefore, researches on ice covering increasing test of different types of conductors under different meteorological conditions have been conducted in large-sized multi-functional phytotron, thus obtaining the relation curve of ice covering increasing of conductor along with time under different conditions, and analyzing factors influencing increasing of ice covering. The research result shows that under the same ice covering conditions, the increasing of ice covering of conductor with small diameter is relatively rapid; both environmental temperature and wind speed have obvious influence on increasing of ice covering of conductor, and the environmental temperature will decide the type of ice covering of conductor surface. Meanwhile, after wind tunnel tests targeting conductors with different ice covering shapes, pneumatic stability loss characteristics of conductors with different ice shapes have been obtained. Research results have important scientific reference value for revealing the mechanism of galloping of iced power transmission line, and have relatively high engineering practicability value for promoting realization of early warning system for galloping of iced power transmission line.

  19. Flux qubit to a transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Haeberlein, Max; Baust, Alexander; Zhong, Ling; Gross, Rudolf [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Nanosystems Initiative Munich (NIM), Muenchen (Germany); Anderson, Gustav; Wang, Lujun; Eder, Peter; Fischer, Michael; Goetz, Jan; Xie, Edwar; Schwarz, Manuel; Wulschner, Karl Friedrich; Deppe, Frank; Fedorov, Kirill; Huebl, Hans; Menzel, Edwin [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Marx, Achim [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany)

    2015-07-01

    Within the last decade, superconducting qubits coupled to microwave resonators have been extensively studied within the framework of quantum electrodynamics. Ultimately, quantum computing seems within reach in such architectures. However, error correction schemes are necessary to achieve the required fidelity in multi-qubit operations, drastically increasing the number of qubits involved. In this work, we couple a flux qubit to a transmission line where it interacts with itinerant microwave photons granting access to all-optical quantum computing. In this approach, travelling photons generate entanglement between two waveguides, containing the qubit information. In this presentation, we show experimental data on flux qubits coupled to transmission lines. Furthermore, we will discuss entanglement generation between two separate paths.

  20. Electrical and Biological Effects of Transmission Lines: A Review.

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jack M.

    1989-06-01

    This review describes the electrical properties of a-c and d-c transmission lines and the resulting effects on plants, animals, and people. Methods used by BPA to mitigate undesirable effects are also discussed. Although much of the information in this review pertains to high-voltage transmission lines, information on distribution lines and electrical appliances is included. The electrical properties discussed are electric and magnetic fields and corona: first for alternating-current (a-c) lines, then for direct current (d-c).

  1. Computation of nonuniform transmission lines using the FDTD method

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, G.C.; Paulino, J.O.S. [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil). School of Engineering

    1997-12-31

    Calculation of lightning overvoltages on transmission lines has been described. Lightning induced overvoltages are of great significance under certain conditions because of the main characteristics of the phenomena. The lightning channel model is one of the most important parameters essential to obtaining the generated electromagnetic fields. In this study, nonuniform transmission line equations were solved using the finite difference method and the leap-frog scheme, the Finite Difference Time Domain (FDTD) method. The subroutine was interfaced with the Electromagnetic Transients Program (EMTP). Two models were used to represent the characteristic impedance of the nonuniform lines used to model the transmission line towers and the lightning main channel. The advantages of the FDTD method was the much smaller code and faster processing time. 35 refs., 5 figs.

  2. Fort Peck-Wolf Point transmission line project, Montana

    International Nuclear Information System (INIS)

    1992-01-01

    The primary objective of the project is to replace the existing 36-mile Fort Peck-Wolf Point transmission line which has reached the end of its useful service life. Presently, the overall condition of this existing section of the 47-year-old line is poor. Frequent repairs have been required because of the absence of overhead ground wires. The continued maintenance of the line will become more expensive and customer interruptions will persist because of the damage due to lightning. The expense of replacing shell rotted poles, and the concern for the safety of the maintenance personnel because of hazards caused by severe shell rot are also of primary importance. The operational and maintenance problems coupled with power system simulation studies, demonstrate the need for improvements to the Wolf Point area to serve area loads. Western's Wolf Point Substation is an important point of interconnection for the power output from the Fort Peck Dam to area loads as far away as Williston, North Dakota. The proposed transmission line replacement would assure that there will continue to be reliable transmission capacity available to serve area electrical loads, as well as provide a reliable second high-voltage transmission path from the Fort Peck generation to back-up a loss of the Fort Peck-Wolf Point 115-kV Line No. 1

  3. Lossy transmission line model of hydrofractured well dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Patzek, T.W. [Department of Materials Science and Mineral Engineering, University of California at Berkeley, Berkeley, CA (United States); De, A. [Earth Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2000-01-01

    The real-time detection of hydrofracture growth is crucial to the successful operation of water, CO{sub 2} or steam injection wells in low-permeability reservoirs and to the prevention of subsidence and well failure. In this paper, we describe propagation of very low frequency (1-10 to 100 Hz) Stoneley waves in a fluid-filled wellbore and their interactions with the fundamental wave mode in a vertical hydrofracture. We demonstrate that Stoneley-wave loses energy to the fracture and the energy transfer from the wellbore to the fracture opening is most efficient in soft rocks. We conclude that placing the wave source and receivers beneath the injection packer provides the most efficient means of hydrofracture monitoring. We then present the lossy transmission line model of wellbore and fracture for the detection and characterization of fracture state and volume. We show that this model captures the wellbore and fracture geometry, the physical properties of injected fluid and the wellbore-fracture system dynamics. The model is then compared with experimentally measured well responses. The simulated responses are in good agreement with published experimental data from several water injection wells with depths ranging from 1000 ft to 9000 ft. Hence, we conclude that the transmission line model of water injectors adequately captures wellbore and fracture dynamics. Using an extensive data set for the South Belridge Diatomite waterfloods, we demonstrate that even for very shallow wells the fracture size and state can be adequately recognized at wellhead. Finally, we simulate the effects of hydrofracture extension on the transient response to a pulse signal generated at wellhead. We show that hydrofracture extensions can indeed be detected by monitoring the wellhead pressure at sufficiently low frequencies.

  4. The LHCb VELO analogue transmission line

    International Nuclear Information System (INIS)

    Bay, A.; Borel, J.; Buytaert, J.; De Laere, S.; Frei, R.; Haefeli, G.; Koppenburg, P.; Locatelli, L.; Schneider, O.; Zehr, F.

    2010-01-01

    The Vertex Locator is one of the most important sub-detectors of the LHCb experiment, which is devoted to B physics. The signals from the silicon strip sensors are multiplexed at 40 MHz and transported by 60 m copper lines to the counting stations placed in a radiation safe area. This paper describes the development of this long transmission line and its performance.

  5. Design of the Yang magnetically-insulated transmission line

    International Nuclear Information System (INIS)

    Gu Yuanchao; Song Shenyi

    2002-01-01

    The authors have designed a new magnetically insulated transmission line (MITL) for the Yang accelerator. The differences between the existing line and the designing one are given. The electric strength of some special regions on the lines and the inductance of the lines have been calculated. The authors have checked the states of magnetic insulation on the designing line

  6. Composite Based EHV AC Overhead Transmission Lines

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard

    and analysed with regard to the possibilities, limitations and risks widespread application of composite materials on EHV AC overhead transmission lines may present. To form the basis for evaluation of the useability of composite materials, dierent overhead line projects aimed at reducing the environmental...

  7. Two profitless delays for an SEIRS epidemic disease model with vertical transmission and pulse vaccination

    International Nuclear Information System (INIS)

    Meng Xinzhu; Jiao Jianjun; Chen Lansun

    2009-01-01

    Since the investigation of impulsive delay differential equations is beginning, the literature on delay epidemic models with pulse vaccination is not extensive. In this paper, we propose a new SEIRS epidemic disease model with two profitless delays and vertical transmission, and analyze the dynamics behaviors of the model under pulse vaccination. Using the discrete dynamical system determined by the stroboscopic map, we obtain a 'infection-free' periodic solution, further, show that the 'infection-free' periodic solution is globally attractive when some parameters of the model are under appropriate conditions. Using a new modeling method, we obtain sufficient condition for the permanence of the epidemic model with pulse vaccination. We show that time delays, pulse vaccination and vertical transmission can bring different effects on the dynamics behaviors of the model by numerical analysis. Our results also show the delays are 'profitless'. In this paper, the main feature is to introduce two discrete time delays, vertical transmission and impulse into SEIRS epidemic model and to give pulse vaccination strategies.

  8. 49 CFR 192.705 - Transmission lines: Patrolling.

    Science.gov (United States)

    2010-10-01

    ... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and other factors affecting safety and operation. (b) The frequency of patrols is determined by the size of the line, the operating pressures, the class location, terrain, weather, and other relevant factors, but...

  9. Requirements for self-magnetically insulated transmission lines

    Directory of Open Access Journals (Sweden)

    J. Pace VanDevender

    2015-03-01

    Full Text Available Self-magnetically insulated transmission lines (MITLs connect pulsed-power drivers with a load. Although the technology was originally developed in the 1970s and is widely used today in super power generators, failure of the technology is the principal limitation on the power that can be delivered to an experiment. We address issues that are often overlooked, rejected after inadequate simulations, or covered by overly conservative assumptions: (i electron retrapping in coupling MITLs to loads, (ii the applicability of collisionless versus collisional electron flow, (iii power transport efficiency as a function of the geometry at the beginning of the MITL, (iv gap closure and when gap closure can be neglected, and (v the role of negative ions in causing anode plasmas and enhancing current losses. We suggest a practical set of conservative design requirements for self-magnetically insulated electron flow based on the results discussed in this paper and on previously published results. The requirements are not necessarily severe constraints in all MITL applications; however, each of the 18 suggested requirements should be examined in the design of a MITL and in the investigation of excessive losses.

  10. A Delay Line for Compression of Electromagnetic Pulses

    International Nuclear Information System (INIS)

    Pchelnikov, Yuriy N.; Nyce, David S.

    2003-01-01

    A novel method to obtain an electromagnetic signal delay is described. It is shown that the positive magnetic and electric coupling between impedance conductors produces an increase in the time delay. It is also shown that the increase in delay time is obtained without additional attenuation. This allows a reduction in electromagnetic losses, by a factor of several times, for a delay time. An approximate analysis of electromagnetic delay lines based on coupled impedance conductors with 'spiral' and 'meander' patterns allowed obtaining very simple expressions for the wave deceleration factor, wave impedance, and attenuation factor. The results of the analysis are confirmed by the results of measurements. It is shown that a delay line based on counter-wound radial spirals can be successfully used for compression of electromagnetic pulses. Although the offered delay line was designed to operate with a relatively small signal, the analysis of the 'coupling effect', taking place in this delay line, might be useful in devices for compression of high-power microwave pulses

  11. Pulsed power

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The key element of our pulsed power program is concentration of power in time and space by suppression of breakdown in dielectrics and in vacuum. Magnetically insulated vacuum transmission lines and magnetic suppression of insulator flashover have continued as the main reserch directions. Vacuum insulated line studies at Physics International have been expanded and a test bed at Sandia, called MITE (Magnetically Insulated Transmission Experiment), is under development. The choice for the baseline EBFA design will depend on the outcome of these studies and should be made in July 1977. The slow and intermediate speed pulsed power approaches to EBFA will be based on Proto I and Proto II results and several of the projected EBFA subsystems are presently being tested in Proto II. A further stage of power concentration, within the vacuum diode itself, would considerably ease the burden on dielectrics; methods of power multiplication involving magnetically imploded plasmas are being considered and tests have begun using the Ripple III apparatus

  12. Neutron resonance transmission spectroscopy with high spatial and energy resolution at the J-PARC pulsed neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu [University of California at Berkeley, 7 Gauss Way, Berkeley, CA 94720 (United States); Shinohara, T.; Kai, T.; Ooi, M. [Japan Atomic Energy Agency, 2–4 Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki 319-1195 (Japan); Kamiyama, T.; Kiyanagi, Y.; Shiota, Y. [Hokkaido University, Kita 13 Nishi 8 Kita-ku, Sapporo-shi, Hokkaido 060-8628 (Japan); McPhate, J.B.; Vallerga, J.V.; Siegmund, O.H.W. [University of California at Berkeley, 7 Gauss Way, Berkeley, CA 94720 (United States); Feller, W.B. [NOVA Scientific, Inc., 10 Picker Rd., Sturbridge, MA 01566 (United States)

    2014-05-11

    The sharp variation of neutron attenuation at certain energies specific to particular nuclides (the lower range being from ∼1 eV up to ∼1 keV), can be exploited for the remote mapping of element and/or isotope distributions, as well as temperature probing, within relatively thick samples. Intense pulsed neutron beam-lines at spallation sources combined with a high spatial, high-timing resolution neutron counting detector, provide a unique opportunity to measure neutron transmission spectra through the time-of-flight technique. We present the results of experiments where spatially resolved neutron resonances were measured, at energies up to 50 keV. These experiments were performed with the intense flux low background NOBORU neutron beamline at the J-PARC neutron source and the high timing resolution (∼20 ns at epithermal neutron energies) and spatial resolution (∼55 µm) neutron counting detector using microchannel plates coupled to a Timepix electronic readout. Simultaneous element-specific imaging was carried out for several materials, at a spatial resolution of ∼150 µm. The high timing resolution of our detector combined with the low background beamline, also enabled characterization of the neutron pulse itself – specifically its pulse width, which varies with neutron energy. The results of our measurements are in good agreement with the predicted results for the double pulse structure of the J-PARC facility, which provides two 100 ns-wide proton pulses separated by 600 ns, broadened by the neutron energy moderation process. Thermal neutron radiography can be conducted simultaneously with resonance transmission spectroscopy, and can reveal the internal structure of the samples. The transmission spectra measured in our experiments demonstrate the feasibility of mapping elemental distributions using this non-destructive technique, for those elements (and in certain cases, specific isotopes), which have resonance energies below a few keV, and with lower

  13. Canby Area Service Project substation and associated transmission line

    International Nuclear Information System (INIS)

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ''environmental impact statement'' is not required

  14. California-Oregon 500-kV transmission line development of design criteria

    International Nuclear Information System (INIS)

    Simpson, K.D.

    1990-01-01

    The California-Oregon Transmission Project (COTP) encompassed the design and construction of a third 500-kV ac intertie between California and the Pacific Northwest Transmission system. Sargent ampersand Lundy's (S ampersand L) scope of work in the COTP includes the design of approximately 150 miles of new single-circuit, 500-kV transmission line from southern Oregon to the vicinity of Redding, California. This paper presents the development of the design criteria for this segment of the project, which crosses diverse topographic and climatic regions. This project is an example of the increasing utilization of computers in transmission line engineering. Almost all aspects of design involved the use of the computer. Also, the development of the design criteria for this project coincided with an early release of the TLWorkstation software package by EPRI. TLWorkstation is an engineering workstation containing a family of programs for various aspects of transmission line design. This engineering software allows for increasing refinement in the design and economic optimization of transmission lines and is becoming an important design tool for transmission engineers

  15. EC Transmission Line Risk Identification and Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bigelow, Tim S [ORNL

    2012-04-01

    The purpose of this document is to assist in evaluating and planning for the cost, schedule, and technical project risks associated with the delivery and operation of the EC (Electron cyclotron) transmission line system. In general, the major risks that are anticipated to be encountered during the project delivery phase associated with the implementation of the Procurement Arrangement for the EC transmission line system are associated with: (1) Undefined or changing requirements (e.g., functional or regulatory requirements) (2) Underperformance of prototype, first unit, or production components during testing (3) Unavailability of qualified vendors for critical components Technical risks associated with the design and operation of the system are also identified.

  16. Improved Field Homogeneity for Transmission Line MRI Coils Using Series Capacitors

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Dong, Yunfeng

    2015-01-01

    High field magnetic resonance imaging (MRI) systems often use short sections of transmission lines for generating and sensing alternating magnetic fields. Due to distributed nature of transmission lines, the generated field is inhomogeneous. This work investigates the application of series capaci...... capacitors to improve the field homogeneity. The resulting magnetic field distribution is estimated analytically and evaluated numerically. The results are compared to a case of a conventional transmission line coil realization....

  17. Pulsed power performance of PBFA Z

    International Nuclear Information System (INIS)

    Spielman, R.B.; Stygar, W.A.; Seamen, J.F.

    1997-01-01

    PBFA Z is a new 60-TW/5-MJ electrical driver located at Sandia National Laboratories. The authors use PBFA Z to drive z pinches. The pulsed power design of PBFA Z is based on conventional single-pulse Marx generator, water-line pulse-forming technology used on the earlier Saturn and PBFA II accelerators. PBFA Z stores 11.4 MJ in its 36 Marx generators, couples 5 MJ in a 60-TW/105-ns pulse to the output water transmission lines, and delivers 3.0 MJ and 50 TW of electrical energy to the z-pinch load. Depending on the initial load inductance and the implosion time, the authors attain peak currents of 16-20 MA with a rise time of 105 ns. Current is fed to the z-pinch load through self magnetically-insulated transmission lines (MITLs). Peak electric fields in the MITLs exceed 2 MV/cm. The current from the four independent conical-disk MITLs is combined together in a double post-hole vacuum convolute with an efficiency greater than 95%. The authors achieved x-ray powers of 200 TW and x-ray energies of 1.9 MJ from tungsten wire-array z-pinch loads

  18. Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

    Science.gov (United States)

    Host, Nick; Chen, Chi-Chih; Volakis, John L.; Miranda, Felix

    2013-01-01

    Phased array antennas showcase many advantages over mechanically steered systems. However, they are also more complex, heavy and most importantly costly. This presentation paper presents a concept which overcomes these detrimental attributes by eliminating all of the phase array backend (including phase shifters). Instead, a wave velocity reconfigurable transmission line is used in a series fed array arrangement to allow phase shifting with one small (100mil) mechanical motion. Different configurations of the reconfigurable wave velocity transmission line are discussed and simulated and experimental results are presented.

  19. Centralized Coordination of Load Shedding & Protection System of Transmission Lines

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2018-01-01

    The power system integrity is vulnerable to thermal limit of transmission lines due to overloading and consequently activation of their protection devices following severe contingencies. In this paper, the loading rate of transmission lines is monitored online and is considered in the centralized......, over current protection....

  20. Shaping the output pulse of a linear-transformer-driver module

    International Nuclear Information System (INIS)

    Long, Finis W.; McKee, G. Randall; Stoltzfus, Brian Scott; Woodworth, Joseph Ray; McKenney, John Lee; Fowler, William E.; Mazarakis, Michael Gerrassimos; Porter, John L.; Stygar, William A.; Savage, Mark Edward; LeChien, Keith R.; Van De Valde, David M.

    2008-01-01

    We demonstrate that a wide variety of current-pulse shapes can be generated using a linear-transformer-driver (LTD) module that drives an internal water-insulated transmission line. The shapes are produced by varying the timing and initial charge voltage of each of the module's cavities. The LTD-driven accelerator architecture outlined in (Phys. Rev. ST Accel. Beams 10, 030401 (2007)) provides additional pulse-shaping flexibility by allowing the modules that drive the accelerator to be triggered at different times. The module output pulses would be combined and symmetrized by water-insulated radial-transmission-line impedance transformers (Phys. Rev. ST Accel. Beams 11, 030401 (2008))

  1. Optocoupled line receiver input discriminates against narrow noise pulses

    CERN Document Server

    Napier, T M

    1977-01-01

    Describes a simple optocoupled interface which connects a data line to the receiving end of a data link that features pulse length discrimination to enhance noise pulse rejection. A rugged red LED, D /sub 1/, can bypass any reasonable fault currents to protect the relatively fragile optocoupler input diode. (0 refs).

  2. Upgrading transmission lines with aerial LiDAR technology

    Energy Technology Data Exchange (ETDEWEB)

    Koop, J.E. [Manitoba Hydro, Winnipeg, MB (Canada)

    2003-04-01

    LiDAR (Light Detection and Ranging) technology is described as an example of techniques used by hydro companies to increase their capacity with existing plants, and within tight budget constraints. LiDAR was chosen by Manitoba Hydro primarily because LiDAR's data collection method offers very fast turn-around time from collection to delivery, and most importantly because of LiDAR's highly accurate ability to map terrain and wire catenary shape in every span. The article describes a case study of the 'Nip and Tuck' method of wire re-tensioning based on LiDAR data, which was used by Manitoba Hydro to create a computer model of Saskatchewan Hydro's transmission line capacity on its 138 kV transmission line between Saskatoon and North Battleford. The model was needed to analyze the existing line conditions in an effort to minimize cascading failures on the 40-year old line. Using the 'Nip and Tuck' technology in combination with LiDAR, SaskPower engineers were able to complete the required modifications to raise transmission wire operating temperatures on the 135 km long line to 66 degree C in only 36 days, and at a cost that was 80 per cent less than the cost would have been using conventional techniques ($232,000 instead of the estimated $1.25 million).

  3. Recent progress of the improved magnetically insulated transmission line oscillator.

    Science.gov (United States)

    Fan, Yu-Wei; Zhong, Hui-Huang; Li, Zhi-Qiang; Shu, Ting; Zhang, Jian-De; Liu, Jin-Liang; Yang, Jian-Hua; Zhang, Jun; Yuan, Cheng-Wei; Luo, Ling

    2008-03-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube driven by a 550 kV, 57 kA, 50 ns electron beam. It has allowed us to generate 2.4 GW pulse of 22 ns duration. The recent progress of the improved MILO is presented in this paper. First, a field shaper cathode is introduced into the improved MILO to avoid the cathode flares in the triple point region. The experimental results show that the cathode flares are avoided, so the lifetime of the velvet cathode is longer than that of the taper cathode. Furthermore, the shot-to-shot reproducibility is better than that of the taper cathode. Second, In order to prolong the pulse duration and increase the radiated microwave power, a self-built 600 kV, 10 Omega, 80 ns pulser: SPARK-03 is employed to drive the improved MILO. Simulation and experimental investigation are performed. In simulation, when the improved MILO is driven by a 600 kV, 57 kA electron beam, high-power microwave is generated with output power of 4.15 GW, frequency of 1.76 GHz, and relevant power conversion efficiency of 12.0%. In experiments, when the diode voltage is 550 kV and current is 54 kA, the measured results are that the radiated microwave power is above 3.1 GW, the pulse duration is above 40 ns, the microwave frequency is about 1.755 GHz, and the power conversion efficiency is about 10.4%.

  4. Advanced high-speed protection for transmission lines with different configurations

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, D.; Naisani, P. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada); Apostolov, A. [Omicron Electronics, Houston, TX (United States)

    2008-07-01

    Power substations and transmission lines require intelligent (microprocessor-based) electronic devices (IED) for data acquisition, protection, metering, and control. This paper presented a universal transmission line protection relay with segregated phase differential protection as the main function and multiple backup protection functions, including 3 zone distance protection. It described features allowing the application of the IED to multi-terminal lines, mutual coupled lines, charging current compensation, transformer inrush current detection, breaker and a half and ring bus substation configurations. GPS synchronized current differential protection offers reliable protection for transmission and distribution circuits. The security of the protection relay can be improved significantly by combining it with fallback techniques to cover loss of GPS synchronizing, and by including non-differential elements as back-up during route switching and channel failures. 7 figs.

  5. Ground-Wave Propagation Effects on Transmission Lines through Error Images

    Directory of Open Access Journals (Sweden)

    Uribe-Campos Felipe Alejandro

    2014-07-01

    Full Text Available Electromagnetic transient calculation of overhead transmission lines is strongly influenced by the natural resistivity of the ground. This varies from 1-10K (Ω·m depending on several media factors and on the physical composition of the ground. The accuracy on the calculation of a system transient response depends in part in the ground return model, which should consider the line geometry, the electrical resistivity and the frequency dependence of the power source. Up to date, there are only a few reports on the specialized literature about analyzing the effects produced by the presence of an imperfectly conducting ground of transmission lines in a transient state. A broad range analysis of three of the most often used ground-return models for calculating electromagnetic transients of overhead transmission lines is performed in this paper. The behavior of modal propagation in ground is analyzed here into effects of first and second order. Finally, a numerical tool based on relative error images is proposed in this paper as an aid for the analyst engineer to estimate the incurred error by using approximate ground-return models when calculating transients of overhead transmission lines.

  6. Characteristics of a four element gyromagnetic nonlinear transmission line array high power microwave source

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J. M., E-mail: jared.johnson@ttu.edu; Reale, D. V.; Garcia, R. S.; Cravey, W. H.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J. [Center for Pulsed Power and Power Electronics Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409 (United States); Krile, J. T. [Department of Electromagnetics and Sensor Systems, Naval Surface Warfare Center - Dahlgren Division, Dahlgren, Virginia 22448 (United States)

    2016-05-15

    In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of ±16.7° is also demonstrated, and the associated general radiation pattern is detailed.

  7. Environmental pollution by magnetic field associated with power transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Hamza, Abdel-Salam H. A.; Ghania, Samy M. [Faculty of Engineering, Zagazig University (Banha Branch), 9-EI-Hakim Be-Amr EI-Ahh Str, EI- Khalafawy, Shoubra, Cairo (Egypt); Mohmoudh, Shaher A. [Ministry of Electricity and Energy (Egypt)

    2002-11-01

    Environmental pollution has a major effect on human health and other life types. A source of environmental pollution is the magnetic field produced near high and extra high voltage (EHV) transmission lines. Magnetic fields from AC EHV lines have been discussed in this paper. The field profiles and their contribution to environmental pollution are studied, these being under transmission lines with different line system configurations, using the three dimensional approaches. These line system configurations are more commonly used in Egypt and other countries. The obtained results are found to be useful for discussing the comparison of the field densities on the human body and other life types at the ground level under or near the lines. (Author)

  8. Coaxial tube array space transmission line characterization

    International Nuclear Information System (INIS)

    Switzer, C.A.; Bents, D.J.

    1987-01-01

    The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance

  9. VT Electric Transmission Line Corridors - substation points

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The ELTRN layer depicts electric transmission line corridors in Vermont. Various methods have been used to digitize features. The data layer...

  10. STUDY OF TRANSMISSION LINES EFFECT ON THE SYSTEM OPERATIONON OF CONTINUOUS AUTOMATIC CAB SIGNALLING

    Directory of Open Access Journals (Sweden)

    O. O. Hololobova

    2014-10-01

    Full Text Available Purpose. To conduct an effect research of the electromagnetic field of high-voltage transmission lines (HVTL (750 kV, 50 Hz on the track circuits and continuous automatic cab signalling (CACS with a signal current of 50 Hz in the areas of convergence and intersection with the transmission lines and to propose possible methods to improve noise immunity of CACS. Methodology. The measurements were performed both by means of car-laboratory and directly on rail lines. During the study the electric field strength in the range of industrial frequency directly under the transmission lines and at the distance from it to the railway lines was measured, as well as the time dependence of CACS codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and its passing. Findings. The root causes analysis of CACS faults and failures was carried out. The effect of the electromagnetic field of high-voltage transmission lines (750 kV, 50 Hz on the track circuit and CACS with signal current of 50 Hz in the areas of convergence and intersection with the transmission line was investigated. Possible methods to improve noise immunity of CACS were considered. Originality. The effect research of transmission lines (750 kV on the operation of the automatic cab signalling on spans Prishib-Burchatsk and Privolnoye-Yelizarovo, Pridneprovsk railway in places of oblique railroads crossing and transmission lines (750 kV, 50 Hz was conducted. Electric field strength in the range of industrial frequency directly under the transmission lines and at a distance from it to the railway line, as well as the time dependences of ALSN codes with signal current frequency of 50 Hz directly under the transmission lines and at a distance from it in the absence of the train and as its passing were measured. It was found that CACS codes in track circuits under transmission lines are strongly distorted, as strength

  11. E-Textile Embroidered Metamaterial Transmission Line for Signal Propagation Control

    Directory of Open Access Journals (Sweden)

    Bahareh Moradi

    2018-06-01

    Full Text Available In this paper, the utilization of common fabrics for the manufacturing of e-textile metamaterial transmission lines is investigated. In order to filter and control the signal propagation in the ultra-high frequency (UHF range along the e-textile, a conventional metamaterial transmission line was compared with embroidered metamaterial particles. The proposed design was based on a transmission line loaded with one or several split-ring resonators (SRR on a felt substrate. To explore the relations between physical parameters and filter performance characteristics, theoretical models based on transmission matrices’ description of the filter constituent components were proposed. Excellent agreement between theoretical prediction, electromagnetic simulations, and measurement were found. Experimental results showed stop-band levels higher than −30 dB for compact embroidered metamaterial e-textiles. The validated results confirmed embroidery as a useful technique to obtain customized electromagnetic properties, such as filtering, on wearable applications.

  12. E-Textile Embroidered Metamaterial Transmission Line for Signal Propagation Control.

    Science.gov (United States)

    Moradi, Bahareh; Fernández-García, Raul; Gil, Ignacio

    2018-06-05

    In this paper, the utilization of common fabrics for the manufacturing of e-textile metamaterial transmission lines is investigated. In order to filter and control the signal propagation in the ultra-high frequency (UHF) range along the e-textile, a conventional metamaterial transmission line was compared with embroidered metamaterial particles. The proposed design was based on a transmission line loaded with one or several split-ring resonators (SRR) on a felt substrate. To explore the relations between physical parameters and filter performance characteristics, theoretical models based on transmission matrices' description of the filter constituent components were proposed. Excellent agreement between theoretical prediction, electromagnetic simulations, and measurement were found. Experimental results showed stop-band levels higher than -30 dB for compact embroidered metamaterial e-textiles. The validated results confirmed embroidery as a useful technique to obtain customized electromagnetic properties, such as filtering, on wearable applications.

  13. Analysis of Crystallographic Structure of a Japanese Sword by the Pulsed Neutron Transmission Method

    Science.gov (United States)

    Kino, K.; Ayukawa, N.; Kiyanagi, Y.; Uchida, T.; Uno, S.; Grazzi, F.; Scherillo, A.

    We measured two-dimensional transmission spectra of pulsed neutron beams for a Japanese sword sample. Atom density, crystalline size, and preferred orientation of crystals were obtained using the RITS code. The position dependence of the atomic density is consistent with the shape of the sample. The crystalline size is very small and shows position dependence, which is understood by the unique structure of Japanese swords. The preferred orientation has strong position dependence. Our study shows the usefulness of the pulsed neutron transmission method for cultural metal artifacts.

  14. A high-voltage pulse generator for corona plasma generation

    NARCIS (Netherlands)

    Yan, K.; Heesch, van E.J.M.; Pemen, A.J.M.; Huijbrechts, P.A.H.J.; Gompel, van F.M.; Leuken, van H.E.M.; Matyas, Z.

    2002-01-01

    This paper discusses a high-voltage pulse generator for producing corona plasma. The generator consists of three resonant charging circuits, a transmission line transformer, and a triggered spark-gap switch. Voltage pulses in the order of 30-100 kV with a rise time of 10-20 ns, a pulse duration of

  15. Two-dimensional electron flow in pulsed power transmission lines and plasma opening switches

    International Nuclear Information System (INIS)

    Church, B.W.; Longcope, D.W.; Ng, C.K.; Sudan, R.N.

    1991-01-01

    The operation of magnetically insulated transmission lines (MITL) and the interruption of current in a plasma opening switch (POS) are determined by the physics of the electrons emitted by the cathode surface. A mathematical model describes the self-consistent two-dimensional flow of an electron fluid. A finite element code, FERUS, has been developed to solve the two equations which describe Poisson's and Ampere's law in two dimensions. The solutions from this code are obtained for parameters where the electron orbits are considerably modified by the self-magnetic field of the current. Next, the self-insulated electron flow in a MITL with a step change in cross-section is studied using a conventional two-dimensional fully electromagnetic particle-in-cell code, MASK. The equations governing two-dimensional quasi-static electron flow are solved numerically by a third technique which is suitable for predicting current interruption in a POS. The object of the study is to determine the critical load impedance, Z CL , required for current interruption for a given applied voltage, cathode voltage and plasma length. (author). 9 refs, 5 figs

  16. Induction effect of an electromagnetic pulse on transmission line

    International Nuclear Information System (INIS)

    Pazirandeh, A.; Maleki, P.; Sardari, D.

    2004-01-01

    Ever increasing demand for and vital importance of communication systems and power transmission to our industries, transportation to work, hospitals, and many other important places deemed necessary to have safety based design considerations. Many natural phenomena and man-made devices may generate powerful and intensive EMP, which is very harmful to the safe mode operation of electrical and communicational systems. In this paper we have calculated induced electric field and power induction due to lightening, nuclear explosion and similar events to the aerial and underground cables

  17. Linear induction accelerators made from pulse-line cavities with external pulse injection

    International Nuclear Information System (INIS)

    Smith, I.

    1979-01-01

    Two types of linear induction accelerator have been reported previously. In one, unidirectional voltage pulses are generated outside the accelerator and injected into the accelerator cavity modules, which contain ferromagnetic material to reduce energy losses in the form of currents induced, in parallel with the beam, in the cavity structure. In the other type, the accelerator cavity modules are themselves pulse-forming lines with energy storage and switches; parallel current losses are made zero by the use of circuits that generate bidirectional acceleration waveforms with a zero voltage-time integral. In a third type of design described here, the cavities are externally driven, and 100% efficient coupling of energy to the beam is obtained by designing the external pulse generators to produce bidirectional voltage waveforms with zero voltage-time integral. A design for such a pulse generator is described that is itself one hundred percent efficient and which is well suited to existing pulse power techniques. Two accelerator cavity designs are described that can couple the pulse from such a generator to the beam; one of these designs provides voltage doubling. Comparison is made between the accelerating gradients that can be obtained with this and the preceding types of induction accelerator

  18. Transmission Line Ampacity Improvements of AltaLink Wind Plant Overhead Tie-Lines Using Weather-Based Dynamic Line Rating

    Energy Technology Data Exchange (ETDEWEB)

    Bhattarai, Bishnu P.; Gentle, Jake P.; Hill, Porter; McJunkin, Tim; Myers, Kurt S.; Abbound, Alex; Renwick, Rodger; Hengst, David

    2017-07-01

    Abstract—Overhead transmission lines (TLs) are conventionally given seasonal ratings based on conservative environmental assumptions. Such an approach often results in underutilization of the line ampacity as the worst conditions prevail only for a short period over a year/season. We presents dynamic line rating (DLR) as an enabling smart grid technology that adaptively computes ratings of TLs based on local weather conditions to utilize additional headroom of existing lines. In particular, general line ampacity state solver utilizes measured weather data for computing the real-time thermal rating of the TLs. The performance of the presented method is demonstrated from a field study of DLR technology implementation on four TL segments at AltaLink, Canada. The performance is evaluated and quantified by comparing the existing static and proposed dynamic line ratings, and the potential benefits of DLR for enhanced transmission assets utilization. For the given line segments, the proposed DLR results in real-time ratings above the seasonal static ratings for most of the time; up to 95.1% of the time, with a mean increase of 72% over static rating.

  19. Nonlinear Seismic Behavior of Different Boundary Conditions of Transmission Line Systems under Earthquake Loading

    Directory of Open Access Journals (Sweden)

    Li Tian

    2016-01-01

    Full Text Available Nonlinear seismic behaviors of different boundary conditions of transmission line system under earthquake loading are investigated in this paper. The transmission lines are modeled by cable element accounting for the nonlinearity of the cable. For the suspension type, three towers and two span lines with spring model (Model 1 and three towers and four span lines’ model (Model 2 are established, respectively. For the tension type, three towers and two span lines’ model (Model 3 and three towers and four span lines’ model (Model 4 are created, respectively. The frequencies of the transmission towers and transmission lines of the suspension type and tension type are calculated, respectively. The responses of the suspension type and tension type are investigated using nonlinear time history analysis method, respectively. The results show that the responses of the transmission tower and transmission line of the two models of the suspension type are slightly different. However, the responses of transmission tower and transmission line of the two models of the tension type are significantly different. Therefore, in order to obtain accurate results, a reasonable model should be considered. The results could provide a reference for the seismic analysis of the transmission tower-line system.

  20. TLINES: A Computer Program for Circuits of Transmission Lines.

    Science.gov (United States)

    1983-12-01

    of various lengths are handled by stringing together many short lines, with the assumption that each of the longer lines has a length approximated as...expressed in terms of transmission lines numbered from 2 through CAPM , connected in numerical sequence as in figure 3. Line 1 is a dummy element disconnected...from line 2 and the rest of the circuit. Lines 2 through CAPM can each be set to any impedance the user desires. Line CAPM +1 is a zero-impedance line

  1. Rigorous theoretical derivation of lumped models to transmission line systems

    International Nuclear Information System (INIS)

    Zhao Jixiang

    2012-01-01

    By virtue of the negative electric parameter concept, i.e. negative lumped resistance, inductance, conductance and capacitance (N-RLGC), the lumped equivalent models of transmission line systems, including the circuit model, two-port π-network and T-network, are given. We start from the N-segment-ladder-like equivalent networks composed distributed parameters, and achieve the input impedance in the form of a continued fraction. Utilizing the continued fraction theory, the expressions of input impedance are obtained under three kinds of extreme cases, i.e. the load impedances are equal to zero, infinity and characteristic impedance, respectively. When the number of segment N is limited to infinity, they are transformed to lumped elements. Comparison between the distributed model and lumped model of transmission lines, the expression of tanh γd, which is the key term in the transmission line equations, are obtained by RLGC, furthermore, according to input admittance, admittance matrix and ABCD matrix of transmission lines, the lumped equivalent circuit models, π-networks and T-networks have been given. The models are verified in the frequency and time domain, respectively, showing that the models are accurate and efficient. (semiconductor integrated circuits)

  2. Repetitive MEGAMP per microsecond di/dt pulsers for driving sub-ohm transmission line neutrino particle detectors

    International Nuclear Information System (INIS)

    Krausse, G.J.

    1980-01-01

    With the advent of low-cost honeycomb extrusions of polypropylene sheets, transmission line flash chambers have become highly attractive candidates for large particle detector arrays. This has brought about the need for repetitive pulse systems that must provide exceptionally high peak currents, low levels of spurious radiation, high reliability, and shot life in excess of 10 7 . Each module of 10 flash chambers requires a peak current of 20 kA with a current di/dt greater than 1 MA/μs. The pulser output must develop approx. = 7 kV across a load of 0.5 Ω with a pulse width of 500 ns. The complete system will require 40 pulsers run in parallel for a combined current output of 1.4 MA peak with a system di/dt of 40 MA/μs. The repetition rate will be up to 2 Hz. This paper describes the development of such a system, its unique voltage and current diagnostics, and the impact of the physical limitations of present component technology on lifetime, reliability, maintainability, and pulse fidelity

  3. Pressure control of a pneumatic control system with a long transmission line

    International Nuclear Information System (INIS)

    Jang, Ji Seong; Lee, Kwang Kuk; Choi, Myung Soo

    2003-01-01

    In this study, a robust controller to control pressure in a pneumatic pressure vessel with a long transmission line is proposed. Frequency response of transmission line using compressible fluid is changed by the flowing state of the fluid. So, if a fixed gain controller designed based on a model supposed the flowing state to a specific state, the performance of the control system could be degraded because of the modelling error. The controller designed in this study is composed of two parts. One is a feedback controller to improve a feedback characteristics and to compensate the influence of the variation of transfer characteristics of a transmission line owing to the change of flowing state and the other is a feed forward controller to regulate command following performance. The experimental results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model of the transmission line. Therefore, the designed controller can be utilized for the performance improvement of a pressure control system with a long transmission line using compressible fluid

  4. Analysis of Power Network for Line Reactance Variation to Improve Total Transmission Capacity

    Directory of Open Access Journals (Sweden)

    Ikram Ullah

    2016-11-01

    Full Text Available The increasing growth in power demand and the penetration of renewable distributed generations in competitive electricity market demands large and flexible capacity from the transmission grid to reduce transmission bottlenecks. The bottlenecks cause transmission congestion, reliability problems, restrict competition, and limit the maximum dispatch of low cost generations in the network. The electricity system requires efficient utilization of the current transmission capability to improve the Available Transfer Capability (ATC. To improve the ATC, power flow among the lines can be managed by using Flexible AC Transmission System (FACTS devices as power flow controllers, which alter the parameters of power lines. It is important to place FACTS devices on suitable lines to vary the reactance for improving Total Transmission Capacity (TTC of the network and provide flexibility in the power flow. In this paper a transmission network is analyzed based on line parameters variation to improve TTC of the interconnected system. Lines are selected for placing FACTS devices based on real power flow Performance Index (PI sensitivity factors. TTC is computed using the Repeated Power Flow (RPF method using the constraints of lines thermal limits, bus voltage limits and generator limits. The reactance of suitable lines, selected on the basis of PI sensitivity factors are changed to divert the power flow to other lines with enough transfer capacity available. The improvement of TTC using line reactance variation is demonstrated with three IEEE test systems with multi-area networks. The results show the variation of the selected lines’ reactance in improving TTC for all the test networks with defined contingency cases.

  5. Real-time pulse deinterleaving using digital delay line techniques

    Science.gov (United States)

    Lentz, L. F.; Palermo, T. J.

    This paper describes an implementation of a tracking pulse sorter based on predictive gating techniques. Real-time pulse sorters or pulse train gating devices have been utilized by the ELINT signal analyst for many years. The more elementary of these devices employed a retriggerable delay interval and an acceptance gate, which were used in predictive fashion to track pulse trains whose PRIs fall within the limits of the programmed delay interval. This design utilizes the pulse hit/miss history of individual track files in a variation of a sequential observer detection algorithm. Use of a digital delay line with pulse history allows multiple pulse trains to be tracked simultaneously and independently without interference. The design also provides flexibility in lock-on and track criteria to allow maintenance of acquisition probability and false alarm rate in dense signal environments and with low SNRs. The hardware provides time interval resolution to 12.5 nsec and covers a PRI range of 50 microsec to 50 msec.

  6. Explanation of the Inverse Doppler Effect Observed in Nonlinear Transmission Lines

    International Nuclear Information System (INIS)

    Kozyrev, Alexander B.; Weide, Daniel W. van der

    2005-01-01

    The theory of the inverse Doppler effect recently observed in magnetic nonlinear transmission lines is developed. We explain the crucial role of the backward spatial harmonic in the occurrence of an inverse Doppler effect and draw analogies of the magnetic nonlinear transmission line to the backward wave oscillator

  7. Wireless Sensor Network for Electric Transmission Line Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Alphenaar, Bruce

    2009-06-30

    Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications

  8. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network.

    Science.gov (United States)

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin

    2014-06-01

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  9. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network

    Energy Technology Data Exchange (ETDEWEB)

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang, E-mail: zhaoliang0526@163.com; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin [Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi' an, Shaanxi 710024 (China)

    2014-06-15

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  10. Optimal Value of Series Capacitors for Uniform Field Distribution in Transmission Line MRI Coils

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy

    2016-01-01

    Transmission lines are often used as coils in high field magnetic resonance imaging (MRI). Due to the distributed nature of transmission lines, coils based on them produce inhomogeneous field. This work investigates application of series capacitors to improve field homogeneity along the coil....... The equations for optimal values of evenly distributed capacitors are derived and expressed in terms of the implemented transmission line parameters.The achieved magnetic field homogeneity is estimated under quasistatic approximation and compared to the regular transmission line resonator. Finally, a more...... practical case of a microstrip line coil with two series capacitors is considered....

  11. Research on UAV Intelligent Obstacle Avoidance Technology During Inspection of Transmission Line

    Science.gov (United States)

    Wei, Chuanhu; Zhang, Fei; Yin, Chaoyuan; Liu, Yue; Liu, Liang; Li, Zongyu; Wang, Wanguo

    Autonomous obstacle avoidance of unmanned aerial vehicle (hereinafter referred to as UAV) in electric power line inspection process has important significance for operation safety and economy for UAV intelligent inspection system of transmission line as main content of UAV intelligent inspection system on transmission line. In the paper, principles of UAV inspection obstacle avoidance technology of transmission line are introduced. UAV inspection obstacle avoidance technology based on particle swarm global optimization algorithm is proposed after common obstacle avoidance technologies are studied. Stimulation comparison is implemented with traditional UAV inspection obstacle avoidance technology which adopts artificial potential field method. Results show that UAV inspection strategy of particle swarm optimization algorithm, adopted in the paper, is prominently better than UAV inspection strategy of artificial potential field method in the aspects of obstacle avoidance effect and the ability of returning to preset inspection track after passing through the obstacle. An effective method is provided for UAV inspection obstacle avoidance of transmission line.

  12. Coaxial transmission line - Equalization

    International Nuclear Information System (INIS)

    Bonnerue, J.L.; Fremont, Jacques; Haubtmann, Jack; Pillon, Gerard.

    1981-09-01

    The transmission of electrical signal through a coaxial line is not perfect and signal distortions are increased as much as the frequency spectrum is extended. We have designed and achieved passive filters (named equalizers) with transfer functions which are inverse of coaxial transfer functions. Doing so our attempt is to avoid definitive loss of information in the recorded data. The main feature of our equalization method lies in the fact it could be either an electrical or a numerical correction or both of them. Some examples in the use of this technique are also proposed [fr

  13. Three-dimensional electromagnetic model of the pulsed-power Z-pinch accelerator

    Directory of Open Access Journals (Sweden)

    D. V. Rose

    2010-01-01

    Full Text Available A three-dimensional, fully electromagnetic model of the principal pulsed-power components of the 26-MA ZR accelerator [D. H. McDaniel et al., in Proceedings of the 5th International Conference on Dense Z-Pinches (AIP, New York, 2002, p. 23] has been developed. This large-scale simulation model tracks the evolution of electromagnetic waves through the accelerator’s intermediate-storage capacitors, laser-triggered gas switches, pulse-forming lines, water switches, triplate transmission lines, and water convolute to the vacuum insulator stack. The insulator-stack electrodes are coupled to a transmission-line circuit model of the four-level magnetically insulated vacuum-transmission-line section and double-post-hole convolute. The vacuum-section circuit model is terminated by a one-dimensional self-consistent dynamic model of an imploding z-pinch load. The simulation results are compared with electrical measurements made throughout the ZR accelerator, and are in good agreement with the data, especially for times until peak load power. This modeling effort demonstrates that 3D electromagnetic models of large-scale, multiple-module, pulsed-power accelerators are now computationally tractable. This, in turn, presents new opportunities for simulating the operation of existing pulsed-power systems used in a variety of high-energy-density-physics and radiographic applications, as well as even higher-power next-generation accelerators before they are constructed.

  14. Remote Control System of the TJ-II Microwave Transmission Lines Mirrors

    International Nuclear Information System (INIS)

    Lopez Sanchez, A.; Fernandez, A.; Cappa, A.; Gama, J. de la; Olivares, J.; Garcia, R.; Chamorro, M.

    2007-01-01

    The ECRH system of the TJ-II stellarator has two gyrotrons, which deliver a maximum power of 300 kW each at a frequency of 53.2 GHz. Another 28 GHz gyrotron will be used to heat the plasma by electron Bernstein waves (EBWH). The microwave power is transmitted from the gyrotrons to the vacuum chamber by two quasi-optical transmission lines for ECRH and a corrugated waveguide for EBWH. All transmission lines have an internal movable mirror inside the vacuum chamber to focus the beam and to be able to change the launching angle. The control of the beam polarization is very important and the lines have two corrugated mirrors, which actuate as polarizers. In this report the control system of the position of these three internal mirrors and the polarizers of the EBWH transmission line is described. (Author) 20 refs

  15. Powerful nanosecond pulse train generator

    International Nuclear Information System (INIS)

    Isakov, I.F.; Logachev, E.I.; Opekunov, M.S.; Pechenkin, S.A.; Remnev, G.E.; Usov, Yu.P.

    1987-01-01

    A generator permitting to shape on the load pulsed with the repetition frequency of 10 3 -10 6 Hz and more is described. The amplitude of shaped voltage pulses is up to 150 kV at pulse duration equal to 50 ns. The generator comprises connected in-series with the load two shaping and two transmission lines realized on the base of the KVI-300 low-ohmic cable. The shaping lines are supplied from two independently connected pulse voltage generators for obtaining time interval between pulses > 10 -6 s; they may be also supplied from one generator for obtaining time interval -6 s. At the expense of reducing losses in the discharge circuit the amplitude of the second pulse grows with increase of time interval between pulses up to 300 ns, further on the curve flat-topping exists. The described generator is used in high-current accelerators, in which the primary negative pulse results in generation of explosive-emission plasma, and the second positive pulse provides ion beam shaping including ions of heavy metal used for production of a potential electrode. The generator multipulse mode is used for successive ion acceleration in the transport system

  16. Application of superconductors to motors, generators, and transmission lines

    International Nuclear Information System (INIS)

    Kirtley, J.L.

    1989-01-01

    Superconductors are of interest to the designers of electric power equipment because they can carry current without loss, currents that are large enough to make very intense magnetic fields. This means that superconductors, used in suitable applications, can make electric power equipment smaller, lighter, more efficient, and perhaps with better dynamic response. Two specific applications are considered here: electric machinery (motors and generators) and transmission lines. The so-called high-T c superconductors will have beneficial impact on motors, generators, and transmission lines only if conductors with sufficient mechanical properties and current-carrying capabilities can be developed

  17. Dynamic Model for the Z Accelerator Vacuum Section Based on Transmission Line Code%Dynamic Model for the Z Accelerator Vacuum Section Based on Transmission Line Code

    Institute of Scientific and Technical Information of China (English)

    呼义翔; 雷天时; 吴撼宇; 郭宁; 韩娟娟; 邱爱慈; 王亮平; 黄涛; 丛培天; 张信军; 李岩; 曾正中; 孙铁平

    2011-01-01

    The transmission-line-circuit model of the Z accelerator, developed originally by W. A. STYGAR, P. A. CORCORAN, et al., is revised. The revised model uses different calculations for the electron loss and flow impedance in the magnetically insulated transmission line system of the Z accelerator before and after magnetic insulation is established. By including electron pressure and zero electric field at the cathode, a closed set of equations is obtained at each time step, and dynamic shunt resistance (used to represent any electron loss to the anode) and flow impedance are solved, which have been incorporated into the transmission line code for simulations of the vacuum section in the Z accelerator. Finally, the results are discussed in comparison with earlier findings to show the effectiveness and limitations of the model.

  18. Tornado risk model for transmission line design

    CSIR Research Space (South Africa)

    Milford, RV

    1997-11-01

    Full Text Available is in combination with ice loading. The wind load used in most codes of practice and design recommendations for transmission line design have until recently been based almost exclusively on large-scale wind storms, which may include severe storms such as hurricanes...

  19. A test of a 2 Tesla superconducting transmission line magnet system

    International Nuclear Information System (INIS)

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring, Roger; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; Wake, Masayoshi

    2005-01-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized

  20. A test of a 2 Tesla superconducting transmission line magnet system

    Energy Technology Data Exchange (ETDEWEB)

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring,; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; /Fermilab; Wake, Masayoshi; /KEK, Tsukuba

    2005-09-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized.

  1. A universal calculation model for the controlled electric transmission line

    International Nuclear Information System (INIS)

    Zivzivadze, O.; Zivzivadze, L.

    2009-01-01

    Difficulties associated with the development of calculation models are analyzed, and the ways of resolution of these problems are given. A version of the equivalent circuit as a six-pole network, the parameters of which do not depend on the angle of shift Θ between the voltage vectors of circuits is offered. The interrelation between the parameters of the equivalent circuit and the transmission constants of the line was determined. A universal calculation model for the controlled electric transmission line was elaborated. The model allows calculating the stationary modes of lines of such classes at any angle of shift Θ between the circuits. (author)

  2. Sensor Placement For Structural Monitoring of Transmission Line Towers

    Directory of Open Access Journals (Sweden)

    Benny eRaphael

    2015-11-01

    Full Text Available Transmission line towers are usually analyzed using linear elastic idealized truss models. Due to the assumptions used in the analysis, there are discrepancies between the actual results obtained from full scale prototype testing and the analytical results. Therefore, design engineers are interested in assessing the actual stress levels in transmission line towers. Since it is costly to place sensors on every member of a tower structure, the best locations for sensors need to be carefully selected. This study evaluates a methodology for sensor placement in transmission line towers. The objective is to find optimal locations for sensors such that the real behavior of the structure can be explained from measurements. The methodology is based on the concepts of entropy and model falsification. Sensor locations are selected based on maximum entropy such that there is maximum separation between model instances that represent different possible combinations of parameter values which have uncertainties. The performance of the proposed algorithm is compared to that of an intuitive method in which sensor locations are selected where the forces are maximum. A typical 220 kV transmission tower is taken as case study in this paper. It is shown that the intuitive method results in much higher number of non-separable models compared to the optimal sensor placement algorithm. Thus the intuitive method results in poor identification of the system.

  3. Electric field simulation and measurement of a pulse line ion accelerator

    International Nuclear Information System (INIS)

    Shen Xiaokang; Zhang Zimin; Cao Shuchun; Zhao Hongwei; Zhao Quantang; Liu Ming; Jing Yi; Wang Bo; Shen Xiaoli

    2012-01-01

    An oil dielectric helical pulse line to demonstrate the principles of a Pulse Line Ion Accelerator (PLIA) has been designed and fabricated. The simulation of the axial electric field of an accelerator with CST code has been completed and the simulation results show complete agreement with the theoretical calculations. To fully understand the real value of the electric field excited from the helical line in PLIA, an optical electric integrated electric field measurement system was adopted. The measurement result shows that the real magnitude of axial electric field is smaller than that calculated, probably due to the actual pitch of the resister column which is much less than that of helix. (authors)

  4. Research on the optoacoustic communication system for speech transmission by variable laser-pulse repetition rates

    Science.gov (United States)

    Jiang, Hongyan; Qiu, Hongbing; He, Ning; Liao, Xin

    2018-06-01

    For the optoacoustic communication from in-air platforms to submerged apparatus, a method based on speech recognition and variable laser-pulse repetition rates is proposed, which realizes character encoding and transmission for speech. Firstly, the theories and spectrum characteristics of the laser-generated underwater sound are analyzed; and moreover character conversion and encoding for speech as well as the pattern of codes for laser modulation is studied; lastly experiments to verify the system design are carried out. Results show that the optoacoustic system, where laser modulation is controlled by speech-to-character baseband codes, is beneficial to improve flexibility in receiving location for underwater targets as well as real-time performance in information transmission. In the overwater transmitter, a pulse laser is controlled to radiate by speech signals with several repetition rates randomly selected in the range of one to fifty Hz, and then in the underwater receiver laser pulse repetition rate and data can be acquired by the preamble and information codes of the corresponding laser-generated sound. When the energy of the laser pulse is appropriate, real-time transmission for speaker-independent speech can be realized in that way, which solves the problem of underwater bandwidth resource and provides a technical approach for the air-sea communication.

  5. Mass and loss analysis of a space-type radiation cooled insulated DC transmission line

    International Nuclear Information System (INIS)

    Schwarze, g.E.

    1986-01-01

    As both the power levels and transmission distances increase such as for large future nuclear power systems, the transmission line becomes an important element in the power chain between the source and load bus. Thus, the transmission line's characteristics must be determined so that the effect of these characteristics on the total power system can be assessed. These design characteristics include the specific mass, percent power loss, size, voltage and power levels, and operating temperatures of the conductor and insulating materials. In a previous paper, the dc transmission line's characteristics of a noninsulated solid cylindrical conductor were determined. In that analysis the expression derived for the transmission line's mass only included the conductor mass and the operating temperature of the line was that of the conductor. In the analysis of this paper, a single layer of insulation is added to the solid cylindrical conductor. In this analysis the dependency of the dc transmission line's mass, loss, and size on the power and voltage levels, conductor and insulation surface temperatures, transmission distance, and conductor and insulation material properties is determined. This analysis can be extended to multi-layers of insulation but the complexity of the analysis increases as the number of layers increase

  6. Design of Miniaturized 10dB Wideband Branch Line Coupler Using Dual and T-Shape Transmission Lines

    Directory of Open Access Journals (Sweden)

    M. Kumar

    2018-04-01

    Full Text Available This paper presents a design mechanism of miniaturized wideband branch line coupler (BLC with loose coupling of 10 dB. Dual transmission lines are used as a feed network which provides a size reduction of 32% with a fractional bandwidth (FBW of 60% for 10±0.5 dB coupling but return loss performance is found to be poor in the operating band. For further improvement of return loss performance as well as for size reduction of the BLC, a T- shape transmission lines are used instead of series quarter wavelength transmission lines, and hence the overall size reduction of around 44% with FBW of 50.4% is achieved. The return loss and isolation performance is found to be les than 15 dB in the entire operating band (2.5–4.1 GHz with respect to design frequency 3G Hz. The proposed BLC is analyzed, fabricated and tested.

  7. The Evaluation Method of the Lightning Strike on Transmission Lines Aiming at Power Grid Reliability

    Science.gov (United States)

    Wen, Jianfeng; Wu, Jianwei; Huang, Liandong; Geng, Yinan; Yu, zhanqing

    2018-01-01

    Lightning protection of power system focuses on reducing the flashover rate, only distinguishing by the voltage level, without considering the functional differences between the transmission lines, and being lack of analysis the effect on the reliability of power grid. This will lead lightning protection design of general transmission lines is surplus but insufficient for key lines. In order to solve this problem, the analysis method of lightning striking on transmission lines for power grid reliability is given. Full wave process theory is used to analyze the lightning back striking; the leader propagation model is used to describe the process of shielding failure of transmission lines. The index of power grid reliability is introduced and the effect of transmission line fault on the reliability of power system is discussed in detail.

  8. Toeless pulse shaping with a single delay-line network

    International Nuclear Information System (INIS)

    Tauhata, L.; Binns, D.C.

    1976-04-01

    New unipolar delay-line clippers producing negligible cancellation remnant have been developed. Near perfect clipping is achieved using a combination of several types of coaxial cable tranformers working as a phase inverter, a new pulse adder, or an impedance transformer. Only passive elements are used in the bridge network. The construction is simple and the performance is extremely stable and wide in dynamic range and frequency band width. Completely symmetrical bipolar pulses are also easily obtained using this technique

  9. Sound Transmission Through Multi-Panel Structures Lined with Elastic Porous Materials

    Science.gov (United States)

    Bolton, J. S.; Shiau, N.-M.; Kang, Y. J.

    1996-04-01

    Theory and measurements related to sound transmission through double panels lined with elastic porous media are presented. The information has application to the design of noise control barriers and to the optimization of aircraft fuselage transmission loss, for example. The major difference between the work described here and earlier research in this field relates to the treatment of the porous material that is used to line the cavity between the two panels of the double panel structure. Here we have used the porous material theory proposed by Biot since it takes explicit account of all the wave types known to propagate in elastic porous materials. As a result, it is possible to use the theory presented here to calculate the transmission loss of lined double panels at arbitrary angles of incidence; results calculated over a range of incidence angles may then be combined to yield the random incidence transmission loss. In this paper, the equations governing wave propagation in an elastic porous material are first considered briefly and then the general forms for the stresses and displacements within the porous material are given. Those solutions are expressed in terms of a number of constants that can be determined by application of appropriate boundary conditions. The boundary conditions required to model double panels having linings that are either directly attached to the facing panels or separated?!from them by air gaps are presented and discussed. Measurements of the random incidence transmission loss of aluminium double-panel structures lined with polyurethane foam are presented and have been found to be in good agreement with theoretical predictions. Both the theoretical predictions and the measured results have shown that the method by which an elastic porous lining material is attached to the facing panels can have a profound influence on the transmission loss of the panel system. It has been found, for example, that treatments in which the lining material

  10. Coupling and corona effects research plan for transmission lines. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bridges, J E; Formanek, V C

    1976-06-01

    Concern has arisen over the possible effects of electric and magnetic fields produced by EHV-UHV transmission lines. Past and ongoing research concerning the electric and magnetic field effects from EHV-UHV transmission lines was reviewed as it pertains to the following areas: (1) electromagnetic interference, (2) acoustic noise, (3) generation of gaseous effluents, and (4) safety considerations of induced voltages and currents. The intent of this review was to identify the short and long range research projects required to address these areas. The research plan identifies and gives priority to twenty programs in corona and coupling effects. In the case of the corona effects, a number of programs were recommended for acoustic noise and electromagnetic interference to delineate improved power line design criteria in terms of social, meteorological, geographical and cost constraints. Only one project is recommended in the case of ozone generation, because the results of comprehensive analyses, laboratory studies and field measurements have demonstrated that power lines do not contribute significant quantities of ozone. In the case of the coupling effects, a number of programs are recommended for HVAC transmission lines to improve the theoretically developed design guidelines by considering practical constraints. For HVDC transmission lines, programs are suggested to engender a better theoretical understanding and practical measurements capability for the coupling mechanisms of the dc electric and magnetic field with nearby objects. The interrelationship of the programs and their role in a long-term research plan is also discussed.

  11. Influences of the pulsed power supply on corona streamer appearance

    NARCIS (Netherlands)

    Veldhuizen, van E.M.; Briels, T.M.P.; Grabowski, L.R.; Pemen, A.J.M.; Ebert, U.M.

    2005-01-01

    Pulsed positive corona streamers in air are studied by images obtained with an intensified CCD camera. Using a switched capacitor power supply, thin streamers are observed that branch. A power supply consisting of a 4-stage transmission line transformer gives pulses of much higher current to the

  12. Characteristic analysis of coupled transmission lines in stripline-type beam position monitor

    International Nuclear Information System (INIS)

    Suwada, T.

    2013-01-01

    Signal transmission characteristics in stripline electrodes of a stripline-type beam position monitor (BPM) are discussed on the basis of a coupled-mode analysis in electromagnetically coupled transmission lines. The physical prospect in the calibration procedure of stripline electrodes is improved in terms of signal transmission characteristics in the frequency domain. It is demonstrated that in the signal transmission with electromagnetic coupling between the stripline electrodes, the magnetic- and electric-coupling parameters play an important role depending upon the spatial configuration and mechanical structure of the stripline electrodes. In this report, a theoretical analysis, and experimental investigation into signal transmission characteristics and performance in a standard stripline-type BPM are described in detail on the basis of a coupled-mode analysis in uniform transmission lines

  13. Kalman filter estimation of RLC parameters for UMP transmission line

    Directory of Open Access Journals (Sweden)

    Mohd Amin Siti Nur Aishah

    2018-01-01

    Full Text Available This paper present the development of Kalman filter that allows evaluation in the estimation of resistance (R, inductance (L, and capacitance (C values for Universiti Malaysia Pahang (UMP short transmission line. To overcome the weaknesses of existing system such as power losses in the transmission line, Kalman Filter can be a better solution to estimate the parameters. The aim of this paper is to estimate RLC values by using Kalman filter that in the end can increase the system efficiency in UMP. In this research, matlab simulink model is developed to analyse the UMP short transmission line by considering different noise conditions to reprint certain unknown parameters which are difficult to predict. The data is then used for comparison purposes between calculated and estimated values. The results have illustrated that the Kalman Filter estimate accurately the RLC parameters with less error. The comparison of accuracy between Kalman Filter and Least Square method is also presented to evaluate their performances.

  14. Canby Area Service Project substation and associated transmission line. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp`s substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC`s Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC`s substation can accommodate only about 10 percent of the expected additional electric load. BPA`s proposed action is intended to meet SVEC`s increasing electric load. BPA proposes to meet SVEC`s increasing energy load by tapping into BPA`s existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC`s Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ``environmental impact statement`` is not required.

  15. Canby Area Service Project : Substation and Associated Transmission Line : Environmental Assessment.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no environmental impact statement'' is not required.

  16. Manitoba Hydro long-term high-voltage transmission line magnetic field monitoring project

    International Nuclear Information System (INIS)

    Wong, P.S.; Ng, C.K.

    2008-01-01

    As part of the licensing process to construct a new 230 kV transmission line on an existing right-of-way in Manitoba, an electrical effects study was conducted in 1998. The study was part of the environmental assessment program crucial in obtaining government approval to construct the line. Some residents living adjacent to the new transmission circuit expressed concerns about alleged adverse health effects associated with long-term exposure to magnetic fields from high voltage transmission lines. In order to verify the accuracy of the predicted magnetic field levels submitted to the regulatory body in the the electrical effects study and to instill confidence in the residents of the affected communities, a three-year magnetic monitoring project was conducted between 2003 and 2005 along the right-of-way after the new 230kV transmission line was energized by Manitoba Hydro. This paper described the monitoring program, with reference to location; equipment; data analysis; and discussion of results. It was concluded that the long-term monitoring project demonstrated that the magnetic field prediction methodology was well understood and accurate, and provided valuable long-term magnetic field characteristics at the edge of the right-of-way. In addition, when there is opposition to a transmission line, public consultation and education were found to be the best options to arrive at a solution. 3 refs., 1 tab., 12 figs

  17. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    Yomi

    2010-08-18

    Aug 18, 2010 ... transmission lines on ornamental plant growth. Zeki Demir ... The effects of proximity to power-line on specific leaf area and seedling dbh were tested .... during vegetation season is about 72% and common wind blow.

  18. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

  19. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    International Nuclear Information System (INIS)

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park

  20. Environmental impact of high voltage aerial transmission lines

    International Nuclear Information System (INIS)

    Silva, R.P.; Mouallen, M.C.; Quintella, S.E.A.

    1989-01-01

    The identification of environmental impacts caused by the aerial transmission lines and the measures for reducing these impacts are discussed, considering the impact over the soil in different areas, biological effects caused by delayed exposure and visual impacts due to the line structures. A methodology for the impact evaluation and the aspects of the Environmental Impact Studies and Environmental Impact Report are also studied. (C.G.C.). 2 refs, 1 fig

  1. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  2. High voltage transmission lines studies with the use of artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Ekonomou, L. [A.S.PE.T.E. - School of Pedagogical and Technological Education, Department of Electrical Engineering Educators, N. Heraklion, 141 21 Athens (Greece)

    2009-12-15

    The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an additional tool of electric engineers. (author)

  3. 800 kW transmission line research at Leatherhead

    Energy Technology Data Exchange (ETDEWEB)

    1964-05-29

    The experimental transmission line was installed at Leatherhead to enable the Central Electricity Research Laboratories to study the insulators, fittings, and conductors likely to be needed for ac power transmission at voltages up to the equivalent of 800 kV three-phase. Continuous recording will be made of corona power loss and radio and television interference. For this purpose C.E.R.L. has developed a statistical radio-interference recorder. The instrumentation also includes an automatic corona-loss bridge and data logger.

  4. Discrete PSO algorithm based optimization of transmission lines loading in TNEP problem

    International Nuclear Information System (INIS)

    Shayeghi, H.; Mahdavi, M.; Bagheri, A.

    2010-01-01

    Transmission network expansion planning (TNEP) is a basic part of power system planning that determines where, when and how many new transmission lines should be added to the network. Up till now, various methods have been presented to solve the static transmission network expansion planning (STNEP) problem. But in all of these methods, lines adequacy rate has not been considered at the end of planning horizon, i.e. expanded network misses adequacy after some times and needs to be expanded again. In this paper, expansion planning has been implemented by merging lines loading parameter in the STNEP and inserting investment cost into the fitness function constraints using discrete particle swarm optimization (DPSO) algorithm. Expanded network will possess a maximum adequacy to provide load demand and also the transmission lines overloaded later. The proposed idea has been tested on the Garvers network and an actual transmission network of the Azerbaijan regional electric company, Iran, and the results are compared with the decimal codification genetic algorithm (DCGA) technique. The results evaluation shows that the network will possess maximum efficiency economically. Also, it is shown that precision and convergence speed of the proposed DPSO based method for the solution of the STNEP problem is superior to DCGA approach.

  5. A novel transmission line protection using DOST and SVM

    Directory of Open Access Journals (Sweden)

    M. Jaya Bharata Reddy

    2016-06-01

    Full Text Available This paper proposes a smart fault detection, classification and location (SFDCL methodology for transmission systems with multi-generators using discrete orthogonal Stockwell transform (DOST. The methodology is based on synchronized current measurements from remote telemetry units (RTUs installed at both ends of the transmission line. The energy coefficients extracted from the transient current signals due to occurrence of different types of faults using DOST are being utilized for real-time fault detection and classification. Support vector machine (SVM has been deployed for locating the fault distance using the extracted coefficients. A comparative study is performed for establishing the superiority of SVM over other popular computational intelligence methods, such as adaptive neuro-fuzzy inference system (ANFIS and artificial neural network (ANN, for more precise and reliable estimation of fault distance. The results corroborate the effectiveness of the suggested SFDCL algorithm for real-time transmission line fault detection, classification and localization.

  6. Tuning of JET transmission line/antenna system during ICRH

    International Nuclear Information System (INIS)

    Oeberg, J.

    1993-05-01

    The launched toroidal wave spectrum for ICRH and ICRH current drive is controlled by the phasing of the antenna currents. This causes imbalance in the transmission lines, which makes it more difficult to use the full power of the ICRH generators. Further, the generators are sensitive to the amount of reflected power. To reduce the amount of reflected power the transmission lines have to be constantly tuned. To study the tuning three models of the antenna are developed and compared with experimental results. A method is suggested which enables better usage of the generated power using a power correction unit to evenly distribute the power load between the generators. 4 refs, 24 figs

  7. Radio and television interference caused by corona discharges from high-voltage transmission lines

    International Nuclear Information System (INIS)

    Sarmadi, M.

    1996-01-01

    Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in foul weather

  8. Tracing overhead transmission line corridors with regard to environmental and spatial qualities

    Directory of Open Access Journals (Sweden)

    Alenka Cof

    2005-01-01

    Full Text Available The article deals with possibilities for running the proposed overhead transmission line Okroglo-Italian border. The Slovene and Italian methods are shown as methods enabling consideration of environmental and spatial impact within the process of planning overhead transmission line corridors. The Slovene method consists of analyses of attractiveness and vulnerability, whereby the first considers those functional and economic factors that affect spatial attractiveness for overhead transmission lines. Thus we can assess the level of economic and functional suitability of alternative routes of the proposed 400 kilovolt overhead transmission line from transformation station Okroglo (Slovenia to Srednje, Golo Brdo and Vrtojba, three potential contact points on the Slovene–Italian border. In accordance with stipulations of the Law on spatial management vulnerability models were prepared, which were used to simulate the development’s potential negative environmental effects and to analyse suitability, which implies harmonisation of development and protection demands. Their result is a possible corridor that can be developed without significant conflicts. The Italian procedure was developed to trace the transmission line corridor from the Slovenian border to the transformation station in Udine. It was also applied on the Slovenian side. Three groups of factors were considered in the procedure: exclusion, repulsion, and attraction. The much simpler procedure enables comparisons, since it uses the same or at least similar spatial data. In conclusion a short commentary is added about the corridor concept as a planning tool.

  9. 77 FR 35366 - Albany-Eugene Transmission Line Rebuild Project

    Science.gov (United States)

    2012-06-13

    ... materials, removing vegetation including danger trees, and revegetating areas disturbed by construction... implement the Proposed Action Alternative, based on the Albany-Eugene Transmission Line Rebuild Project (DOE...

  10. Research on Poppers Used as Electrical Connectors in High Speed Textile Transmission Lines

    Directory of Open Access Journals (Sweden)

    Leśnikowski Jacek

    2016-12-01

    Full Text Available This paper presents results of research on poppers used as electrical connectors connecting fragments of textile signal lines. These lines can be used in intelligent clothing for connecting electronic modules implemented in it. Intelligent (smart clothing can be used, among others, in the health monitoring of the elderly, newborn babies, or people working in hazardous conditions, for example, firefighters and soldiers. The aim of the present study was to examine the usefulness of poppers, widely used in clothing, as electrical connectors connecting parts of the textile signal lines designed for transmission of high-speed digital signals. The paper presents examples of measured parameters characterizing transmission properties of two fragments of the coplanar, textile transmission line connected to each other using conventional poppers. The presented measurement results contain the so-called s parameters, characteristic impedance of the poppers, and eye measurements characterizing distortions of digital signals passing through the tested line. In the article, the effect of temperature and humidity of air surrounding the tested poppers on their characteristic impedance was also presented. This property and its stability are important in signal lines designed for high-speed data transmission.

  11. Design and development of a high-power, 500 kV pulsed line

    International Nuclear Information System (INIS)

    Nicolas, A.

    A study was made of very high voltage (500 kV) pulse production for 50 ns at half height. A coaxial line was coupled to a Marx generator for obtaining the pulses on an impedance-adapted electron diode. The maximum power obtained was 6.4 x 10 10 W with a current front in the diode of about 30 ns (80 ns pulse length at half height)

  12. Radiating nonuniform transmission-line systems and the partial element equivalent circuit method

    CERN Document Server

    Nitsch, Juergen; Wollenberg, Gunter

    2009-01-01

    High frequencies of densely packed modern electronic equipment turn even the smallest piece of wire into a transmission line with signal retardation, dispersion, attenuation, and distortion. In electromagnetic environments with high-power microwave or ultra-wideband sources, transmission lines pick up noise currents generated by external electromagnetic fields. These are superimposed on essential signals, the lines acting not only as receiving antennas but radiating parts of the signal energy into the environment. This book is outstanding in its originality. While many textbooks rephrase

  13. Magnetically insulated transmission line used for relativistic electron beam injection into SPAC-VI

    International Nuclear Information System (INIS)

    Tsuzuki, Tetsuya; Narihara, Kazumichi; Tomita, Yukihiro; Mohri, Akihiro.

    1980-10-01

    For the purpose to inject the electron beam with energy of about 1.5 MeV and current of about 100 kA into the SPAC-6 (torus device), a magnetically insulated transmission line was designed and constructed. The motion of electrons in the line was theoretically analyzed. The requirements for the design of the transmission line were as follows-: (a) condition of magnetic insulation, (b) suppression against reverse gas flow from the beam source to the torus, (c) care to minimize the influence of strong torus magnetic field, (d) reduction of inductance and (e) safety engineering measures, e.g., separation valve in the MITL between the beam source and the SPAC-6. The transmission line of 2.4 m long was designed and constructed. The wave forms of electric potential and current were measured. The transmission efficiency of current along the axis and the efficiency as a function of current at the end of the line were also measured. The reason of the loss of current is discussed. (J.P.N.)

  14. High power RF transmission line component development

    International Nuclear Information System (INIS)

    Hong, B. G.; Hwang, C. K.; Bae, Y. D.; Yoon, J. S.; Wang, S. J.; Gu, S. H.; Yang, J. R.; Hahm, Y. S.; Oh, G. S.; Lee, J. R.; Lee, W. I.; Park, S. H.; Kang, M. S.; Oh, S. H.; Lee, W.I.

    1999-12-01

    We developed the liquid stub and phase shifter which are the key high RF power transmission line components. They show reliable operation characteristics and increased insulation capability, and reduced the size by using liquid (silicon oil, dielectric constant ε=2.72) instead of gas for insulating dielectric material. They do not have finger stock for the electric contact so the local temperature rise due to irregular contact and RF breakdown due to scratch in conductor are prevented. They can be utilized in broadcasting, radar facility which require high RF power transmission. Moreover, they are key components in RF heating system for fusion reactor. (author)

  15. High power RF transmission line component development

    Energy Technology Data Exchange (ETDEWEB)

    Hong, B. G.; Hwang, C. K.; Bae, Y. D.; Yoon, J. S.; Wang, S. J.; Gu, S. H.; Yang, J. R.; Hahm, Y. S.; Oh, G. S.; Lee, J. R.; Lee, W. I.; Park, S. H.; Kang, M. S.; Oh, S. H.; Lee, W.I

    1999-12-01

    We developed the liquid stub and phase shifter which are the key high RF power transmission line components. They show reliable operation characteristics and increased insulation capability, and reduced the size by using liquid (silicon oil, dielectric constant {epsilon}=2.72) instead of gas for insulating dielectric material. They do not have finger stock for the electric contact so the local temperature rise due to irregular contact and RF breakdown due to scratch in conductor are prevented. They can be utilized in broadcasting, radar facility which require high RF power transmission. Moreover, they are key components in RF heating system for fusion reactor. (author)

  16. Study on Writing Transmission Metal Grating with Pulse Shaping of Femtosecond Laser

    International Nuclear Information System (INIS)

    Ni, X C; Sun, Q; Wang, Ch Y; Yang, L; Wu, Y Z; Jia, W; Chai, L

    2006-01-01

    Pulse shaping in femtosecond(fs) laser micromachining is different from that of traditional laser, whose main purpose is to reduce focal scale size, wipe off fluorescence around laser beam, decrease pulse distortion, and fabricate all kinds of figures. To describe the spatial form of laser pulse around focal scale, the synchronous moving of focal objective and accepting material is presented. When a pinhole mask is placed in front of focal objective, the changing trend of laser spatial form around focal point with the laser beam diameter will be obtained by the diameter changing of the hole mask. Experimental results show that the diameter of laser pulse around focal point trends smoothly when the pinhole diameter is modulated to smaller, even the position of beam waist is changed. These phenomena can be explained by optical imaging theory. Finally, the transmission metal grating is written successfully with a selected parameter

  17. Transmission line transformer for reliable and low-jitter triggering of a railgap switch.

    Science.gov (United States)

    Verma, Rishi; Mishra, Ekansh; Sagar, Karuna; Meena, Manraj; Shyam, Anurag

    2014-09-01

    The performance of railgap switch critically relies upon multichannel breakdown between the extended electrodes (rails) in order to ensure distributed current transfer along electrode length and to minimize the switch inductance. The initiation of several simultaneous arc channels along the switch length depends on the gap triggering technique and on the rate at which the electric field changes within the gap. This paper presents design, construction, and output characteristics of a coaxial cable based three-stage transmission line transformer (TLT) that is capable of initiating multichannel breakdown in a high voltage, low inductance railgap switch. In each stage three identical lengths of URM67 coaxial cables have been used in parallel and they have been wounded in separate cassettes to enhance the isolation of the output of transformer from the input. The cascaded output impedance of TLT is ~50 Ω. Along with multi-channel formation over the complete length of electrode rails, significant reduction in jitter (≤2 ns) and conduction delay (≤60 ns) has been observed by the realization of large amplitude (~80 kV), high dV/dt (~6 kV/ns) pulse produced by the indigenously developed TLT based trigger generator. The superior performance of TLT over conventional pulse transformer for railgap triggering application has been compared and demonstrated experimentally.

  18. Sound transmission through triple-panel structures lined with poroelastic materials

    Science.gov (United States)

    Liu, Yu

    2015-03-01

    In this paper, previous theories on the prediction of sound transmission loss for a double-panel structure lined with poroelastic materials are extended to address the problem of a triple-panel structure. Six typical configurations are considered for a triple-panel structure based on the method of coupling the porous layers to the facing panels which determines critically the sound insulation performance of the system. The transfer matrix method is employed to solve the system by applying appropriate types of boundary conditions for these configurations. The transmission loss of the triple-panel structures in a diffuse sound field is calculated as a function of frequency and compared with that of corresponding double-panel structures. Generally, the triple-panel structure with poroelastic linings has superior acoustic performance to the double-panel counterpart, remarkably in the mid-high frequency range and possibly at low frequencies, by selecting appropriate configurations in which those with two air gaps in the structure exhibit the best overall performance over the entire frequency range. The poroelastic lining significantly lowers the cut-on frequency above which the triple-panel structure exhibits noticeably higher transmission loss. Compared with a double-panel structure, the wider range of system parameters for a triple-panel structure due to the additional partition provides more design space for tuning the sound insulation performance. Despite the increased structural complexity, the triple-panel structure lined with poroelastic materials has the obvious advantages in sound transmission loss while without the penalties in weight and volume, and is hence a promising replacement for the widely used double-panel sandwich structure.

  19. Numerical noise analysis for insulator of overhead transmission line

    Science.gov (United States)

    Zhang, Yulin; Chen, Yuwen; Huang, Yu

    2018-04-01

    As an important and complex issue in aero acoustic field, a lot of explorations have been devoted to the wind-induced noise. However, there is still lack of intensive investigations for aerodynamic noise in high-voltage transmission. The overhead transmission line system leads to serious occupational noise exposure in high wind-speed environment, and the noise can even injure the electricians in charge of insulator. By using computational fluid dynamics (CFD) which combined with computational aero acoustics (CAA), this paper predicts the noise generated by insulator of high voltage electricity transmission line which explores in wind environment. The simulation results indicate that the wind velocity, the assembly angle of the insulator and its ribs' distribution are the main contributory factors for the aerodynamic noise. Specifically, when wind velocity is greater than 15m/s, the alteration of noise is not sensitive to the wind velocity; furthermore, when the assembly angle increases from 0°to 60°, the noise decreases gradually, however, if the angle is happening to be 75°or 90°, it would be even greater than that at 0°. In order to inhibit the aerodynamic noise, it is necessary to control the flow blowing across the boundary of the insulator. Consequently, the result indicates that if the outermost rib is shorter than the second one, the noise reduced evidently. This information expects to provide useful help for the extremely suppression of aerodynamic noise, and also supply practical reference material for the design and application of overhead transmission line system.

  20. Analytical Model for High Impedance Fault Analysis in Transmission Lines

    Directory of Open Access Journals (Sweden)

    S. Maximov

    2014-01-01

    Full Text Available A high impedance fault (HIF normally occurs when an overhead power line physically breaks and falls to the ground. Such faults are difficult to detect because they often draw small currents which cannot be detected by conventional overcurrent protection. Furthermore, an electric arc accompanies HIFs, resulting in fire hazard, damage to electrical devices, and risk with human life. This paper presents an analytical model to analyze the interaction between the electric arc associated to HIFs and a transmission line. A joint analytical solution to the wave equation for a transmission line and a nonlinear equation for the arc model is presented. The analytical model is validated by means of comparisons between measured and calculated results. Several cases of study are presented which support the foundation and accuracy of the proposed model.

  1. North Central Transmission Line: Guidelines for the environmental impact statement

    International Nuclear Information System (INIS)

    1992-01-01

    Guidelines that Manitoba Hydro must follow in the preparation of the environmental impact statement on the proposed North Central Transmission Line (TCTL) project are presented. The project consists of a 138 kV transmission line, two 25 kV distribution lines, and related ancillary structures and facilities. The review process must be sensitive to cultural and community needs and must involve those most directly affected, and should be grounded in the impacted northern communities. The review should include a project background, the proposal, a description of the existing natural and socio-economic environment, and must address employment, education and training, impacts on renewable resource harvesting, environmental impacts, social impacts and economic impacts, legal/jurisdictional issues, infrastructure, mitigation and compensation, and environmental monitoring and follow-up. 1 fig., 20 tabs

  2. Electric and magnetic field reduction by alternative transmission line options

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, J.R. (Power Technologies, Inc., Schenectady, NY (United States)); Dale, S.J. (Oak Ridge National Lab., TN (United States)); Klein, K.W. (Energetics, Inc., Columbia, MD (United States))

    1991-01-01

    Ground level electric, and more recently magnetic, fields from overhead power transmission lines are increasingly important considerations in right of way specification, with states setting or planning to set edge of right of way limits. Research has been conducted in high phase order power transmission wherein six of twelve phases are used to transmit power in less physical space and with reduced electrical environmental effects than conventional designs. The first magnetic field testing, as reported in this paper, has verified predictive methods for determination of magnetic fields from high phase order lines. Based on these analytical methods, field profiles have been determined for lines of different phase order of comparable power capacity. Potential advantages of high phase order as a means of field mitigation are discussed. 10 refs., 12 figs., 3 tabs.

  3. Fully controlled 5-phase, 10-pulse, line commutated rectifier

    Directory of Open Access Journals (Sweden)

    Mahmoud I. Masoud

    2015-12-01

    Full Text Available The development and production of multiphase machines either generators or motors, specially five-phase, offers improved performance compared to three-phase counterpart. Five phase generators could generate power in applications such as, but not limited to, wind power generation, electric vehicles, aerospace, and oil and gas. The five-phase generator output requires converter system such as ac–dc converters. In this paper, a fully controlled 10-pulse line commutated rectifier, suitable to be engaged with wind energy applications, fed from five-phase source is introduced. A shunt active power filter (APF is used to improve power factor and supply current total harmonic distortion (THD. Compared to three-phase converters, 6-pulse or 12-pulse rectifiers, the 10-pulse rectifier engaged with 5-phase source alleviate their drawbacks such as high dc ripples and no need for electric gear or phase shifting transformer. MATLAB/SIMULINK platform is used as a simulation tool to investigate the performance of the proposed rectifier.

  4. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  5. Transmission Characteristics of an OFDM signal for Power Line Communication System with High Bit Rate

    Science.gov (United States)

    Mori, Akira; Watanabe, Yosuke; Tokuda, Masamitsu; Kawamoto, Koji

    In this paper, we measured what influence the sinusoidal transmission characteristics of the electric power line with various forms gave to the transmission characteristic of OFDM (Orthogonal Frequency Division Multiplexing) signal through PLC (power line communication system) modem. We classified the electric power line transmission line with various forms in a real environment into two basic elements, which are an outlet type branch and a switch type branch. Next, PHY rate (Physical rate) is measured for each basic element connected with the PLC modem. At this time, the transmission characteristics of the electric power line are simulated from measured data. OFDM sending and receiving systems are composed on the computer, and the PHY rate is simulated. By comparing with measured and calculated values, it is revealed that PHY rate of PLC modem is most affected in the case of the power line transmission characteristics having broad band and high level attenuation and group delay variation, and is not affected in the case of that having narrow band attenuation and group delay variation.

  6. Active high-power RF pulse compression using optically switched resonant delay lines

    International Nuclear Information System (INIS)

    Tantawi, S.G.; Ruth, R.D.; Vlieks, A.E.

    1996-11-01

    The authors present the design and a proof of principle experimental results of an optically controlled high power rf pulse compression system. The design should, in principle, handle few hundreds of Megawatts of power at X-band. The system is based on the switched resonant delay line theory. It employs resonant delay lines as a means of storing rf energy. The coupling to the lines is optimized for maximum energy storage during the charging phase. To discharge the lines, a high power microwave switch increases the coupling to the lines just before the start of the output pulse. The high power microwave switch, required for this system, is realized using optical excitation of an electron-hole plasma layer on the surface of a pure silicon wafer. The switch is designed to operate in the TE 01 mode in a circular waveguide to avoid the edge effects present at the interface between the silicon wafer and the supporting waveguide; thus, enhancing its power handling capability

  7. Breakdown of methylene blue and methyl orange by pulsed corona discharge

    NARCIS (Netherlands)

    Grabowski, L.R.; Veldhuizen, van E.M.; Pemen, A.J.M.; Rutgers, W.R.

    2007-01-01

    The recently developed corona above water technique is applied to water containing 10 mg l-1 methylene blue (MB) or methyl orange (MO). The corona discharge pulses are created with a spark gap switched capacitor followed by a transmission line transformer. The pulse amplitude is 40 kV; its duration

  8. Weld-Windsor 115-kV Transmission Line Project, Weld County, Colorado

    International Nuclear Information System (INIS)

    1996-05-01

    The Western Area Power Administration is proposing to rebuild a 3.0 mile segment of the existing Flatiron-Weld 115-kV transmission line in Weld County. The line would be reconductored with new conductor on new wood pole double circuit structures. The new structures would support a double circuit transmission line configuration. The first circuit would be owned by Western and the second by Public Service Company of Colorado (PSCO). Alternatives considered included no action, constructing PSCO's circuit on new right-of-way, and reconductoring Western's existing line on the same structures. The proposed action was selected because it provided an opportunity to share structures with PSCO and, overall, would minimize costs and environmental impacts. The environmental assessment identifies minor effects on existing natural or human resources and minor benefits for agricultural operations

  9. Pulse shaping for high data rate ultra-wideband wireless transmission under the Russian spectral emission mask

    DEFF Research Database (Denmark)

    Rommel, Simon; Grakhova, Elizaveta P.; Jurado-Navas, Antonio

    2017-01-01

    This paper addresses impulse-radio ultra-wideband (IR-UWB) transmission under the Russian spectral emission mask for unlicensed UWB radio communications. Four pulse shapes are proposed and their bit error rate (BER) performance is both estimated analytically and evaluated experimentally. Well......-known shapes such as the Gaussian, root-raised cosine, hyperbolic secant, and the frequency B-spline wavelet are used to form linear combinations of component pulses, shaped to make efficient use of the spectral emission mask. Analytical BER values are derived using a Nakagami-m model, and good agreement......-UWB transmission under the strict regulations of the Russian spectral emission mask....

  10. Reduction of the visual impact of overhead transmission line systems through utilisation of line surge arresters as lightning protection

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    with the Technical University of Denmark, on how to lessen the visual impact of 400 kV overhead line transmission systems. In this paper omission of shield wires combined with installation of a suitable number of line surge arresters is investigated as a possible alternative to transmission lines equipped...... with shielding wires thereby reducing tower height, allowing more compact designs of towers thus minimizing the visual environment impact of the lines. Omission of shield wires in the system and instead utilizing a larger number of surge arresters in the (upper) phases of an overhead line without reduction...... will be investigated by transient simulations on a 400 kV line with either shield wires or line surge arresters. These simulations will also be used to estimate number and location of the line surge arresters in the line to ensure a satisfactory performance of the line when omitting shield wires in the tower top...

  11. NMR imaging of solids with multiple-pulse line narrowing and radiofrequency gradients

    International Nuclear Information System (INIS)

    Werner, M.H.

    1993-01-01

    The usual methods of magnetic resonance imaging fail in rigid solids due to the line-shape contributions of dipolar coupling, chemical shift dispersion and anisotropy, and bulk magnetic susceptibility. This dissertation presents a new method of solid-stage imaging by nuclear magnetic resonance which averages away these contributions with multiple-pulse line-narrowing and encodes spatial information with pulsed radiofrequency field gradients. This method is closely related to simultaneously developed methods utilizing pulsed DC gradients, and offers similar improvements in sensitivity and resolution. The advantage of rf gradients is that they can be rapidly switched without inducing eddy currents in the probe or the magnet. In addition, the phases and amplitudes of the rf gradients can be switched by equipment which is already part of an NMR spectrometer capable of solid-state spectroscopy. The line-narrowing and gradient pulses originate in separate rf circuits tuned to the same frequency. Interactions between the circuits have been minimized by a method of active Q-switching which employs PIN diodes in the matching networks of these circuits. Both one- and two-dimensional images are presented. The latter are obtained by a novel method in which the two dimensions of imaging transverse to the static magnetic field are encoded by two orthogonal components of a single rf gradient. A π/2 phase shift of the rf phase relative to that of the line-narrowing pulses selects one component or the other. This arrangement allows the solid-state analogs of versatile imaging sequences based on Fourier imaging and eliminates the need for sample rotation and back-projection methods. Coherent averaging theory is used to analyze this imaging technique and exact numerical simulations on several coupled spins are discussed. These lend insight to the residual linewidth and its dependence on pixel position as well as to the range of applicability of this technique

  12. Research on Line Patrol Strategy of 110kV Transmission Line after Lightning Strike

    Directory of Open Access Journals (Sweden)

    Li Mingjun

    2016-01-01

    Full Text Available Lightning faults occupy in the majority of instantaneous fault and reclosing can usually be successful, so power supply can be restored without immediate patrol in many cases. Firstly, this paper introduces the lightning fault positioning and identifying method. Then test electrical performance of insulators after lightning strike from 110kV lines. Data shows that lightning strike has little effect on the electric performance of insulator. Finally, illustrating disposal process of the 110 kV transmission line after lightning fault, certifying that the power supply reliability be ensured without line patrol.

  13. Prediction of the Voltage Quality in an Overhead Transmission Line with Distributed Parameters

    OpenAIRE

    Bulyga Leonid L.; Tarasov Evgeniy V.; Ushakov Vasily Ya.; Kharlov Nikolay N.

    2015-01-01

    The present work is devoted to investigation of an electrical transmission line with allowance for distributed parameters. From the results of voltage measurements at terminals of an actual transmission line, effective values of the voltage are calculated for every line section. Special attention is given to higher harmonics and asymmetry. Spectral composition of the voltage is presented and changes in values of harmonic components are analyzed. The effect of higher harmonics on the equipment...

  14. Environmental impact of the aerial power transmission lines

    International Nuclear Information System (INIS)

    Cristescu, D.; Rusan, R.

    1993-01-01

    In the last 10-12 years the existence of the high voltage lines existence within populated areas has been more and more contested. The paper tries to complete a blank in the Romanian technical literature by introducing the concept of 'line corridor' which is different from the occupied geometric area and from 'the line disturbed corridor'. The concept is meant to specify the area where the high frequency and 50 Hz electromagnetic pollution exceeds some given limits. The impact of the power transmission lines on the human body, due to the effects of the electric and magnetic fields, is considered. Also, the aspects concerning the visual impact, the acoustic and radio noise and the area expensing by the high voltage lines, are considered. International standards and regulations regarding the limitations of this effects are presented. (author)

  15. Location of Faults in Power Transmission Lines Using the ARIMA Method

    Directory of Open Access Journals (Sweden)

    Danilo Pinto Moreira de Souza

    2017-10-01

    Full Text Available One of the major problems in transmission lines is the occurrence of failures that affect the quality of the electric power supplied, as the exact localization of the fault must be known for correction. In order to streamline the work of maintenance teams and standardize services, this paper proposes a method of locating faults in power transmission lines by analyzing the voltage oscillographic signals extracted at the line monitoring terminals. The developed method relates time series models obtained specifically for each failure pattern. The parameters of the autoregressive integrated moving average (ARIMA model are estimated in order to adjust the voltage curves and calculate the distance from the initial fault localization to the terminals. Simulations of the failures are performed through the ATPDraw ® (5.5 software and the analyses were completed using the RStudio ® (1.0.143 software. The results obtained with respect to the failures, which did not involve earth return, were satisfactory when compared with widely used techniques in the literature, particularly when the fault distance became larger in relation to the beginning of the transmission line.

  16. Very Fast Current Diagnostic for Linear Pulsed Beams

    Directory of Open Access Journals (Sweden)

    Nassisi Vincenzo

    2018-01-01

    Full Text Available Fast current pulses manage lasers and particle accelerators and require sophisticate systems to be detected. At today Rogowski coils are well known. They are designed and built with a toroidal structure. In recently application, flat transmission lines are imploded and for this reason we develop a linear Rogowski coil to detect current pulses inside flat conductors. To get deep information from the system, it was approached by means of the theory of the transmission lines. The coil we build presents a resistance but it doesn’t influence the rise time of the response, instead the integrating time. We also studied the influence of the magnetic properties of coil support. The new device was able to record pulses of more hundred nanoseconds depending on the inductance, load impedance and resistance of the coil. Furthermore, its response was characterized by a sub-nanosecond rise time (~100 ps, The attenuation coefficient depends mainly on the turn number of the coil, while the quality of the response depends both on the manufacture quality of the coil and on the magnetic core characteristics. In biophysical applications often, a double line is employed in order to have a sample as control and a sample stressed by a light source. So, in this case we build two equal plane lines by 100 Ω characteristic resistance connected in parallel. We diagnosed the current present in a line. The attenuation factor resulted to be 11,5 A/V.

  17. Very Fast Current Diagnostic for Linear Pulsed Beams

    Science.gov (United States)

    Nassisi, Vincenzo; Delle Side, Domenico; Turco, Vito

    2018-01-01

    Fast current pulses manage lasers and particle accelerators and require sophisticate systems to be detected. At today Rogowski coils are well known. They are designed and built with a toroidal structure. In recently application, flat transmission lines are imploded and for this reason we develop a linear Rogowski coil to detect current pulses inside flat conductors. To get deep information from the system, it was approached by means of the theory of the transmission lines. The coil we build presents a resistance but it doesn't influence the rise time of the response, instead the integrating time. We also studied the influence of the magnetic properties of coil support. The new device was able to record pulses of more hundred nanoseconds depending on the inductance, load impedance and resistance of the coil. Furthermore, its response was characterized by a sub-nanosecond rise time ( 100 ps), The attenuation coefficient depends mainly on the turn number of the coil, while the quality of the response depends both on the manufacture quality of the coil and on the magnetic core characteristics. In biophysical applications often, a double line is employed in order to have a sample as control and a sample stressed by a light source. So, in this case we build two equal plane lines by 100 Ω characteristic resistance connected in parallel. We diagnosed the current present in a line. The attenuation factor resulted to be 11,5 A/V.

  18. Rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC)

    Science.gov (United States)

    Li, Xiuling; Huang, Wen

    2015-04-28

    A rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC) comprises a multilayer sheet in a rolled configuration comprising multiple turns about a longitudinal axis, where the multilayer sheet comprises a conductive pattern layer on a strain-relieved layer. The conductive pattern layer comprises a first conductive film and a second conductive film separated from the first conductive film in a rolling direction. In the rolled configuration, the first conductive film surrounds the longitudinal axis, and the second conductive film surrounds the first conductive film. The first conductive film serves as a signal line and the second conductive film serves as a conductive shield for the rolled-up transmission line structure.

  19. Frequency Selective Properties of Coaxial Transmission Lines Loaded with Combined Artificial Inclusions

    Directory of Open Access Journals (Sweden)

    Francisco Falcone

    2014-01-01

    Full Text Available The properties of a modified coaxial transmission line by periodic inclusions will be discussed. The introduction of split ring resonators, conductor stubs, air gaps, and combination of these gives rise to new frequency selective properties, such as stopband or passband behavior, observable in planar as well as volumetric metamaterial structures. These results envisage new potential applications and implementation of devices in coaxial transmission line technology.

  20. An analytical theory of transmission line shielding

    International Nuclear Information System (INIS)

    Pettersson, Per

    1993-01-01

    The classical electrogeometric model of shielding failure flashovers on transmission lines is investigated by analytical methods. Most of the basic elements that has appeared in the literature on the subject have been incorporated and put into a comprehensive model. These elements are: tower top geometry, structure height above ground, line insulation, lateral slope of ground, probability distribution of lightning currents, ratio of striking distances to ground wire and earth relative to conductor, and probability distribution of lightning leader approach angle to ground. Departing from a basic idealistic case, the sensitivity of the model to variations in these parameters is studied. Numerical examples are given. 8 refs, 8 figs, 1 tab

  1. Simulation of 6 1/8 inch rigid coaxial RF transmission line

    International Nuclear Information System (INIS)

    Soni, Atul; Pande, M.M.; Rao, M.K.V.; Handu, V.K.

    2006-01-01

    A radio frequency (RF) transmission line has been designed based upon rigid coaxial 6 1/8 , 50-ohm line for coupling the RF power from its source to 400 KeV radio frequency quadrupole (RFQ) accelerator. Simulation and analysis have been carried out to evaluate various RF parameters of the line. (author)

  2. Characteristics of the λ/4 transmission line resonator

    International Nuclear Information System (INIS)

    Hashimoto, Y.; Masuda, H.; Yoshida, K.; Arai, S.; Niki, K.

    1994-01-01

    Though the spiral cavity is adequate for low frequency operation, mechanical instability becomes serious for such a low frequency as 20 MHz. We have then studied how to shorten the spiral length by using λ/4 transmission line models. Four models with reduced spiral length are presented. (author)

  3. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Science.gov (United States)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  4. Annular shape silver lined proportional counter for on-line pulsed neutron yield measurement

    International Nuclear Information System (INIS)

    Dighe, P.M.; Das, D.

    2015-01-01

    An annular shape silver lined proportional counter is developed to measure pulsed neutron radiation. The detector has 314 mm overall length and 235 mm overall diameter. The central cavity of 150 mm diameter and 200 mm length is used for placing the neutron source. Because of annular shape the detector covers >3π solid angle of the source. The detector has all welded construction. The detector is developed in two halves for easy mounting and demounting. Each half is an independent detector. Both the halves together give single neutron pulse calibration constant of 4.5×10 4 neutrons/shot count. The detector operates in proportional mode which gives enhanced working conditions in terms of dead time and operating range compared to Geiger Muller based neutron detectors

  5. Prediction of the Voltage Quality in an Overhead Transmission Line with Distributed Parameters

    Directory of Open Access Journals (Sweden)

    Bulyga Leonid L.

    2015-01-01

    Full Text Available The present work is devoted to investigation of an electrical transmission line with allowance for distributed parameters. From the results of voltage measurements at terminals of an actual transmission line, effective values of the voltage are calculated for every line section. Special attention is given to higher harmonics and asymmetry. Spectral composition of the voltage is presented and changes in values of harmonic components are analyzed. The effect of higher harmonics on the equipment operation is analyzed.

  6. Transmission Line for 258 GHz Gyrotron DNP Spectrometry

    Science.gov (United States)

    Bogdashov, Alexandr A.; Belousov, Vladimir I.; Chirkov, Alexey V.; Denisov, Gregory G.; Korchagin, Vyacheslav V.; Kornishin, Sergey Yu.; Tai, Evgeny M.

    2011-06-01

    We describe the design and test results of the transmission line for liquid-state (LS) and solid-state (SS) DNP spectrometers with the second-harmonic 258.6 GHz gyrotron at the Institute of the Biophysical Chemistry Center of Goethe University (Frankfurt). The 13-meter line includes a mode converter, HE11 waveguides, 4 mitre bends, a variable polarizer-attenuator, directional couplers, a water-flow calorimeter and a mechanical switch. A microwave power of about 15 W was obtained in the pure HE11 mode at the spectrometer inputs.

  7. A coaxial-output capacitor-loaded annular pulse forming line.

    Science.gov (United States)

    Li, Rui; Li, Yongdong; Su, Jiancang; Yu, Binxiong; Xu, Xiudong; Zhao, Liang; Cheng, Jie; Zeng, Bo

    2018-04-01

    A coaxial-output capacitor-loaded annular pulse forming line (PFL) is developed in order to reduce the flat top fluctuation amplitude of the forming quasi-square pulse and improve the quality of the pulse waveform produced by a Tesla-pulse forming network (PFN) type pulse generator. A single module composed of three involute dual-plate PFNs is designed, with a characteristic impedance of 2.44 Ω, an electrical length of 15 ns, and a sustaining voltage of 60 kV. The three involute dual-plate PFNs connected in parallel have the same impedance and electrical length. Due to the existed small inductance and capacitance per unit length in each involute dual-plate PFN, the upper cut-off frequency of the PFN is increased. As a result, the entire annular PFL has better high-frequency response capability. Meanwhile, the three dual-plate PFNs discharge in parallel, which is much closer to the coaxial output. The series connecting inductance between adjacent two modules is significantly reduced when the annular PFL modules are connected in series. The pulse waveform distortion is reduced when the pulse transfers along the modules. Finally, the shielding electrode structure is applied on both sides of the module. The electromagnetic field is restricted in the module when a single module discharges, and the electromagnetic coupling between the multi-stage annular PFLs is eliminated. Based on the principle of impedance matching between the multi-stage annular PFL and the coaxial PFL, the structural optimization design of a mixed PFL in a Tesla type pulse generator is completed with the transient field-circuit co-simulation method. The multi-stage annular PFL consists of 18 stage annular PFL modules in series, with the characteristic impedance of 44 Ω, the electrical length of 15 ns, and the sustaining voltage of 1 MV. The mixed PFL can generate quasi-square electrical pulses with a pulse width of 43 ns, and the fluctuation ratio of the pulse flat top is less than 8% when the

  8. A coaxial-output capacitor-loaded annular pulse forming line

    Science.gov (United States)

    Li, Rui; Li, Yongdong; Su, Jiancang; Yu, Binxiong; Xu, Xiudong; Zhao, Liang; Cheng, Jie; Zeng, Bo

    2018-04-01

    A coaxial-output capacitor-loaded annular pulse forming line (PFL) is developed in order to reduce the flat top fluctuation amplitude of the forming quasi-square pulse and improve the quality of the pulse waveform produced by a Tesla-pulse forming network (PFN) type pulse generator. A single module composed of three involute dual-plate PFNs is designed, with a characteristic impedance of 2.44 Ω, an electrical length of 15 ns, and a sustaining voltage of 60 kV. The three involute dual-plate PFNs connected in parallel have the same impedance and electrical length. Due to the existed small inductance and capacitance per unit length in each involute dual-plate PFN, the upper cut-off frequency of the PFN is increased. As a result, the entire annular PFL has better high-frequency response capability. Meanwhile, the three dual-plate PFNs discharge in parallel, which is much closer to the coaxial output. The series connecting inductance between adjacent two modules is significantly reduced when the annular PFL modules are connected in series. The pulse waveform distortion is reduced when the pulse transfers along the modules. Finally, the shielding electrode structure is applied on both sides of the module. The electromagnetic field is restricted in the module when a single module discharges, and the electromagnetic coupling between the multi-stage annular PFLs is eliminated. Based on the principle of impedance matching between the multi-stage annular PFL and the coaxial PFL, the structural optimization design of a mixed PFL in a Tesla type pulse generator is completed with the transient field-circuit co-simulation method. The multi-stage annular PFL consists of 18 stage annular PFL modules in series, with the characteristic impedance of 44 Ω, the electrical length of 15 ns, and the sustaining voltage of 1 MV. The mixed PFL can generate quasi-square electrical pulses with a pulse width of 43 ns, and the fluctuation ratio of the pulse flat top is less than 8% when the

  9. Simulation of loss electron in vacuum magnetically insulated transmission lines

    International Nuclear Information System (INIS)

    Zhang Pengfei; Li Yongdong; Liu Chunliang; Wang Hongguang; Guo Fan; Yang Hailiang; Qiu Aici; Su Zhaofeng; Sun Jianfeng; Sun Jiang; Gao Yi

    2011-01-01

    In the beginning of magnetic insulated period, loss electron in coaxial vacuum magnetically insulated transmission line (MITL) strikes anode and the bremsstrahlung photons are generated in the mean time. Based on the self-limited flow model, velocity in direction of energy transport, energy spectrum and angular distribution of loss electron are simulated by PIC code, energy spectrum of bremsstrahlung photons as well calculated though Monte Carlo method. Computational results show that the velocity of loss electron is less than 2.998 x 108 m/s, the angular excursion of electron is not much in a board extent of energy spectrum. These results show an indirect diagnosis of vacuum insulted transmission line working status based on loss electron bremsstrahlung. (authors)

  10. Cultural-resource survey report: Hoover Dam Powerplant Modification Project II. Associated transmission-line facility

    International Nuclear Information System (INIS)

    Queen, R.L.

    1991-06-01

    The Bureau of Reclamation (Reclamation) is proposing to modify or install additional transmission facilities between the Hoover Dam hydroelectric plant and the Western Area Power Authority substation near Boulder City, Nevada. Reclamation has completed cultural resource investigations to identify historic or prehistoric resources in the project area that might be affected during construction of the transmission line. Four possible transmission corridors approximately 50 feet wide and between 9.5 and 11.5 miles long were investigated. The proposed transmission lines either parallel or replace existing transmission lines. The corridors generally have undergone significant disturbance from past transmission line construction. A Class II sampling survey covering approximately 242 acres was conducted. Access or construction roads have not been identified and surveys of these areas will have to be completed in the future. No historic or prehistoric archeological sites were encountered within the four corridor right-of-ways. It is believed that the probability for prehistoric sites is very low. Four historic period sites were recorded that are outside, but near, the proposed corridor. These sites are not individually eligible for the National Register of Historic Places, but may be associated with the construction of Hoover Dam and contribute to a historic district or multiple property resource area focusing on the dam and its construction

  11. Analytical study for the ability of nonlinear transmission lines to generate solitons

    International Nuclear Information System (INIS)

    Mostafa, S.I.

    2009-01-01

    The ability of the nonlinear transmission lines (NLTL) has been studied analytically, in this paper to generate solitons and to cause waveform spreading. This can be achieved by balancing nonlinearity and dispersion. A new technique of improved tanh method (ITM) and improved sech methods (ISM) is applied to the nonlinear partial differential equation that describes the NLTL. It is found that the parameters of the transmission line play an important role in controlling the shape of the soliton.

  12. Multiwavelet packet entropy and its application in transmission line fault recognition and classification.

    Science.gov (United States)

    Liu, Zhigang; Han, Zhiwei; Zhang, Yang; Zhang, Qiaoge

    2014-11-01

    Multiwavelets possess better properties than traditional wavelets. Multiwavelet packet transformation has more high-frequency information. Spectral entropy can be applied as an analysis index to the complexity or uncertainty of a signal. This paper tries to define four multiwavelet packet entropies to extract the features of different transmission line faults, and uses a radial basis function (RBF) neural network to recognize and classify 10 fault types of power transmission lines. First, the preprocessing and postprocessing problems of multiwavelets are presented. Shannon entropy and Tsallis entropy are introduced, and their difference is discussed. Second, multiwavelet packet energy entropy, time entropy, Shannon singular entropy, and Tsallis singular entropy are defined as the feature extraction methods of transmission line fault signals. Third, the plan of transmission line fault recognition using multiwavelet packet entropies and an RBF neural network is proposed. Finally, the experimental results show that the plan with the four multiwavelet packet energy entropies defined in this paper achieves better performance in fault recognition. The performance with SA4 (symmetric antisymmetric) multiwavelet packet Tsallis singular entropy is the best among the combinations of different multiwavelet packets and the four multiwavelet packet entropies.

  13. Lightning Protection Performance Assessment of Transmission Line Based on ATP model Automatic Generation

    Directory of Open Access Journals (Sweden)

    Luo Hanwu

    2016-01-01

    Full Text Available This paper presents a novel method to solve the initial lightning breakdown current by combing ATP and MATLAB simulation software effectively, with the aims to evaluate the lightning protection performance of transmission line. Firstly, the executable ATP simulation model is generated automatically according to the required information such as power source parameters, tower parameters, overhead line parameters, grounding resistance and lightning current parameters, etc. through an interface program coded by MATLAB. Then, the data are extracted from the generated LIS files which can be obtained by executing the ATP simulation model, the occurrence of transmission lie breakdown can be determined by the relative data in LIS file. The lightning current amplitude should be reduced when the breakdown occurs, and vice the verse. Thus the initial lightning breakdown current of a transmission line with given parameters can be determined accurately by continuously changing the lightning current amplitude, which is realized by a loop computing algorithm that is coded by MATLAB software. The method proposed in this paper can generate the ATP simulation program automatically, and facilitates the lightning protection performance assessment of transmission line.

  14. Modeling digital pulse waveforms by solving one-dimensional Navier-stokes equations.

    Science.gov (United States)

    Fedotov, Aleksandr A; Akulova, Anna S; Akulov, Sergey A

    2016-08-01

    Mathematical modeling for composition distal arterial pulse wave in the blood vessels of the upper limbs was considered. Formation of distal arterial pulse wave is represented as a composition of forward and reflected pulse waves propagating along the arterial vessels. The formal analogy between pulse waves propagation along the human arterial system and the propagation of electrical oscillations in electrical transmission lines with distributed parameters was proposed. Dependencies of pulse wave propagation along the human arterial system were obtained by solving the one-dimensional Navier-Stokes equations for a few special cases.

  15. PSpice for filters and transmission lines

    CERN Document Server

    Tobin, Paul

    2007-01-01

    In this book, PSpice for Filters and Transmission Lines, we examine a range of active and passive filters where each design is simulated using the latest Cadence Orcad V10.5 PSpice capture software. These filters cannot match the very high order digital signal processing (DSP) filters considered in PSpice for Digital Signal Processing, but nevertheless these filters have many uses. The active filters considered were designed using Butterworth and Chebychev approximation loss functions rather than using the 'cookbook approach' so that the final design will meet a given specification in an exact

  16. Theory and Circuit Model for Lossy Coaxial Transmission Line

    Energy Technology Data Exchange (ETDEWEB)

    Genoni, T. C.; Anderson, C. N.; Clark, R. E.; Gansz-Torres, J.; Rose, D. V.; Welch, Dale Robert

    2017-04-01

    The theory of signal propagation in lossy coaxial transmission lines is revisited and new approximate analytic formulas for the line impedance and attenuation are derived. The accuracy of these formulas from DC to 100 GHz is demonstrated by comparison to numerical solutions of the exact field equations. Based on this analysis, a new circuit model is described which accurately reproduces the line response over the entire frequency range. Circuit model calculations are in excellent agreement with the numerical and analytic results, and with finite-difference-time-domain simulations which resolve the skindepths of the conducting walls.

  17. Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

  18. Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska

    International Nuclear Information System (INIS)

    1995-05-01

    The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA)

  19. Simulation of longitudinal differential protection of transmission lines with additional stabilization and APU system

    Directory of Open Access Journals (Sweden)

    Rajić Tomislav D.

    2016-01-01

    Full Text Available This paper explains the algorithm for the longitudinal differential protection of transmission lines with automatic reclosing. Classic stabilization is not sufficient for avoiding of unnecessary operations caused by saturation of current transformer. This problem can occur during the fault plased outside of the protected zone of the transmission line. It is shown how unnecessary operation can occur during the outside fault whithout using of additional stabilization. The different types of faults were simulated and comparison of relay operations with and without additional stabilization is presented. The simulations were performed on the three-phase model of the transmission line formed by using of MATLAB/Simulink program.

  20. Chameleon's behavior of modulable nonlinear electrical transmission line

    Science.gov (United States)

    Togueu Motcheyo, A. B.; Tchinang Tchameu, J. D.; Fewo, S. I.; Tchawoua, C.; Kofane, T. C.

    2017-12-01

    We show that modulable discrete nonlinear transmission line can adopt Chameleon's behavior due to the fact that, without changing its appearance structure, it can become alternatively purely right or left handed line which is different to the composite one. Using a quasidiscrete approximation, we derive a nonlinear Schrödinger equation, that predicts accurately the carrier frequency threshold from the linear analysis. It appears that the increasing of the linear capacitor in parallel in the series branch induced the selectivity of the filter in the right-handed region while it increases band pass filter in the left-handed region. Numerical simulations of the nonlinear model confirm the forward wave in the right handed line and the backward wave in the left handed one.

  1. Comparative study of aerial transmission lines and underground isolated on gas

    International Nuclear Information System (INIS)

    Quesada Jimenez, Marco Esteban

    2012-01-01

    A comparison was made of aerial power lines and underground isolated on gas. Growing electric demand has given way to debate the lines transmission. Multiple discussions have generated about its application, however, the energy must be supplied and this process leads to the search for more efficient methods. The theory has covered the most important design criteria of the airlines and an introduction to the little known transport lines isolated on gas. The process of manufacturing, installation and operation are studied within the scope of the project. Count information is included in the main aspects of calculation relating to power transmission. Besides, the planning of the optimal route nominal calculations, load flow and power losses are focused as well as magnetic field strengths and finally economic analysis. (author) [es

  2. METHODICAL APPROACHES TO THE CHOICE OF THE NEW GENERATION OF HIGH-VOLTAGE POWER TRANSMISSION LINE 220 kV OPTIONS

    Directory of Open Access Journals (Sweden)

    POSTOLATI V.M.

    2010-08-01

    Full Text Available The Transmission Power Lines of new generation are described in the article (single- compact, double-circuit compact, double-circuit Controlled Self-compensating High Voltage Transmission Power Lines (CSHVL. Basic principles of creation, design elements and comparative characteristics of the transmission lines of the new generation are described, the advantages of its are showed. Methodical approaches to the choosing of a new generation of transmission lines and facilities management FACTS are formulated. Methodical approaches to the choice of options for transmission lines 220 kV and facilities management are shown.

  3. Analytical methods for study of transmission line lightning protection

    International Nuclear Information System (INIS)

    Pettersson, Per.

    1993-04-01

    Transmission line lightning performance is studied by analytical methods. The elements of shielding failure flashovers and back-flashovers are analysed as functions of incidence, response and insulation. Closed-form approximate expressions are sought to enhance understanding of the phenomena. Probabilistic and wave propagation aspects are particularly studied. The electrogeometric model of lightning attraction to structures is used in combination with the log-normal probability distribution of lightning to ground currents. The log-normality is found to be retained for the currents collected by mast-type as well as line-type structures, but with a change of scale. For both types, exceedingly simple formulas for the number of hits are derived. Simple closed-form expressions for the line outage rates from back- flashovers and shielding failure flashovers are derived in a uniform way as functions of the critical currents. The expressions involve the standardized normal distribution function. System response is analysed by use of Laplace transforms in combination with text-book transmission-line theory. Inversion into time domain is accomplished by an approximate asymptotic method producing closed-form results. The back-flashover problem is analysed in particular. Approximate, image type expressions are derived for shunt admittance of wires above, on and under ground for analyses of fast transients. The derivation parallels that for series impedance, now well-known. 3 refs, 5 figs

  4. Design of pulse transformers for PFL charging

    International Nuclear Information System (INIS)

    Rohwein, G.J.

    1979-01-01

    Air core pulse transformers powered by low voltage capacitor banks can be simple efficient systems for charging high-voltage (0.5 to 3 MV), pulse forming transmission lines (PFL) such as those used in electron and ion beam accelerators. In these applications pulse transformers must have the combined capability of high voltage endurance and high energy transfer efficiency, particularly in repetitive pulse systems where these features are of primary importance. The design of shielded, high-voltage, spiral, strip transformers which fulfill these requirements is described in this paper. Transformers of this type have been tested in three systems which operate with greater than 90% transfer efficiency and have not failed in over 10 7 shots

  5. Environmental impacts of power plants and transmission lines in power system planning

    International Nuclear Information System (INIS)

    Miracapillo, C.; Moreschini, G.; Rome Univ. 'La Sapienza'

    1992-01-01

    This paper deals with a criterion to assess the environmental impacts of power plants and transmission lines in power system planning. First, the effects of hydro-plants, thermal plants and transmission lines are reviewed. Then, a number of methods for the evaluation of the environmental impacts of civil and industrial plants are described. A new criterion is proposed to introduce the evaluation of the environmental impact and related costs into methods for power system planning. Finally, the criterion is applied to a simple case

  6. High-voltage pulsed generator for dynamic fragmentation of rocks.

    Science.gov (United States)

    Kovalchuk, B M; Kharlov, A V; Vizir, V A; Kumpyak, V V; Zorin, V B; Kiselev, V N

    2010-10-01

    A portable high-voltage (HV) pulsed generator has been designed for rock fragmentation experiments. The generator can be used also for other technological applications. The installation consists of low voltage block, HV block, coaxial transmission line, fragmentation chamber, and control system block. Low voltage block of the generator, consisting of a primary capacitor bank (300 μF) and a thyristor switch, stores pulse energy and transfers it to the HV block. The primary capacitor bank stores energy of 600 J at the maximum charging voltage of 2 kV. HV block includes HV pulsed step up transformer, HV capacitive storage, and two electrode gas switch. The following technical parameters of the generator were achieved: output voltage up to 300 kV, voltage rise time of ∼50 ns, current amplitude of ∼6 kA with the 40 Ω active load, and ∼20 kA in a rock fragmentation regime (with discharge in a rock-water mixture). Typical operation regime is a burst of 1000 pulses with a frequency of 10 Hz. The operation process can be controlled within a wide range of parameters. The entire installation (generator, transmission line, treatment chamber, and measuring probes) is designed like a continuous Faraday's cage (complete shielding) to exclude external electromagnetic perturbations.

  7. High-voltage pulsed generator for dynamic fragmentation of rocks

    Science.gov (United States)

    Kovalchuk, B. M.; Kharlov, A. V.; Vizir, V. A.; Kumpyak, V. V.; Zorin, V. B.; Kiselev, V. N.

    2010-10-01

    A portable high-voltage (HV) pulsed generator has been designed for rock fragmentation experiments. The generator can be used also for other technological applications. The installation consists of low voltage block, HV block, coaxial transmission line, fragmentation chamber, and control system block. Low voltage block of the generator, consisting of a primary capacitor bank (300 μF) and a thyristor switch, stores pulse energy and transfers it to the HV block. The primary capacitor bank stores energy of 600 J at the maximum charging voltage of 2 kV. HV block includes HV pulsed step up transformer, HV capacitive storage, and two electrode gas switch. The following technical parameters of the generator were achieved: output voltage up to 300 kV, voltage rise time of ˜50 ns, current amplitude of ˜6 kA with the 40 Ω active load, and ˜20 kA in a rock fragmentation regime (with discharge in a rock-water mixture). Typical operation regime is a burst of 1000 pulses with a frequency of 10 Hz. The operation process can be controlled within a wide range of parameters. The entire installation (generator, transmission line, treatment chamber, and measuring probes) is designed like a continuous Faraday's cage (complete shielding) to exclude external electromagnetic perturbations.

  8. submitter Superconducting transmission lines – Sustainable electric energy transfer with higher public acceptance?

    CERN Document Server

    Thomas, Heiko; Chervyakov, Alexander; Stückrad, Stefan; Salmieri, Delia; Rubbia, Carlo

    2016-01-01

    Despite the extensive research and development investments into superconducting science and technology, both at the fundamental and at the applied levels, many benefits of superconducting transmission lines (SCTL) remain unknown to the public and decision makers at large. This paper aims at informing about the progress in this important research field. Superconducting transmission lines have a tremendous size advantage and lower total electrical losses for high capacity transmission plus a number of technological advantages compared to solutions based on standard conductors. This leads to a minimized environmental impact and enables an overall more sustainable transmission of electric energy. One of the direct benefits may be an increased public acceptance due to the low visual impact with a subsequent reduction of approval time. The access of remote renewable energy (RE) sources with high-capacity transmission is rendered possible with superior efficiency. That not only translates into further reducing $CO_2...

  9. The Transmission Line for the SPIDER experiment

    International Nuclear Information System (INIS)

    Boldrin, Marco; De Lorenzi, Antonio; Recchia, Mauro; Toigo, Vanni; Bonicelli, Tullio; Simon, Muriel

    2011-01-01

    The 100 keV Ion Source Test facility - Source for the Production of Ions of Deuterium Extracted from RF plasma (SPIDER) - is aimed to test the full scale prototype of the Ion Source for the ITER 1 MeV Neutral Beam Injector (NBI). The SPIDER facility requires the construction of a High Voltage Deck (HVD) and of a High Voltage Transmission Line (TL) respectively to host the Ion Source Power Supplies system polarized at 100 kV and to carry the power and signal conductors to the beam accelerator. In already existing NBI systems with beam energy above 100 keV, the TL is realized with the SF 6 Gas Insulated Line technology. In the SPIDER TL case, the presence of a large inner conductor (half meter diameter), would make the pressurized TL a complex and costly component; therefore a free air insulated solution has been proposed. The paper focuses on the design of this TL, which has to host inside the complex high potential (100 kV) inner electrode a number of power and measuring conductors and has to minimize the Electro Magnetic Interferences (EMI) produced by the frequent grids breakdowns. Finite Element (FE) analyses have been performed to verify the configuration from the electrostatic point of view, to evaluate EMI screening effectiveness and to assess the impact of the relatively high thermal dissipation of power conductors located inside the high potential electrode. Moreover, an experimental test campaign has been carried out on a TL mockup to validate the TL electrostatic configuration under DC voltage. Finally, the paper reports on the status of procurement activities for the Transmission Line.

  10. Study on the Extremely Low Frequency (ELF) Electromagnetic Field (EMF) emission from overhead High-Voltage Transmission Lines

    International Nuclear Information System (INIS)

    Parthasarathy, S.R.; Roha Tukimin; Wan Saffiey Wan Abdullah; Zulkifli Yusof; Mohd Azizi Mohd Jali

    2016-01-01

    The paper highlights the study on the Extremely Low Frequency (ELF) Electromagnetic Field (EMF) emission performed at an overhead 275-kV High-Voltage Transmission Lines. The study comprised of assessment at the transmission lines on 3 different cases and locations in Klang Valley, specifically on a vacant land near the transmission line, inside and around the house at the vicinity of the transmission line and the area directly under the transmission line. The instrument setup and measurement protocols during the assessment were adopted from standard measurement method and procedures stipulated under the Institute of Electrical and Electronics Engineers (IEEE) Standard. The results were compared with the standards recommended in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. The results showed that the measured field strengths are within the safety limit with the highest measured exposure was 10.8 % and 1.8 % of the permissible exposure limit for the electric and magnetic field respectively. Both the field strengths were found to drop significantly against distance from the transmission lines where closer distances showed higher field strengths. Furthermore, the study revealed that buildings and other object such as trees and shrubs screen out the electric field, resulting in a lower value at indoor measurements and near the stated objects. In addition, higher value of electric and magnetic field strengths were recorded when assessment was being done directly under the transmission line compared to the lateral measurement. (author)

  11. Application of reliability based design concepts to transmission line structure foundations. Part 2

    International Nuclear Information System (INIS)

    DiGioia, A.M. Jr.; Rojas-Gonzalez, L.F.

    1991-01-01

    The application of reliability based design (RBD) methods to transmission line structure foundations has developed somewhat more slowly than that for the other structural components in line systems. In a previous paper, a procedure was proposed for the design of transmission line structures foundations using a probability based load and resistance factor design (LRFD) format. This procedure involved the determination of a foundation strength factor, φ F , which was used as a multiplier of the calculated nominal design strength to estimate the five percent exclusion limit strength required in the calculated nominal design strength to estimate the five percent exclusion limit strength required in the LRFD equation. Statistical analyses of results from full-scale load tests were used to obtain φ F values applicable to various nominal design strength equations and for drilled shafts subjected to uplift loads. These results clearly illustrated the significant economic benefits of conducting more detailed subsurface investigations for the design of transmission line structure foundations. A design example was also presented. In this paper the proposed procedure is extended to laterally load drilled shafts

  12. Microscopic simulation model of superconducting transmission lines for standard microwave CAD programs

    International Nuclear Information System (INIS)

    Hoefer, G.J.; Kratz, H.A.

    1993-01-01

    Superconducting lines are very promising candidates for fast signal transmission in integrated circuits, because of their low losses and dispersion, which result in large usable bandwidths. Coplanar waveguides are of special interest, since only one superconducting layer is needed for their implementation. This requirement fits well the present day capabilities of the high temperature superconductor technology. At present, the major drawback of this type of transmission line is the lack of accurate and fast CAD models including the special properties of superconducting electrodes. In the following we will briefly describe the essentials of a model for the case of superconducting lines. For a complete description the reader is referenced to. The model has been proven to be useful in conjunction with commercially available microwave CAD programs. (orig.)

  13. TEr azimuthal modes for a biconic transmission line in the small-gap limit

    International Nuclear Information System (INIS)

    Johnson, W.A.; Mendel, C.W. Jr.; Seidel, D.B.

    1992-01-01

    Azimuthally asymmetric modes in a biconic transmission line with a small-gap angle may be approximated by ''transmission-line-like'' modes. It is shown that the errors in these approximations are second order in the gap angle and approximate error bounds are provided. As an example demonstrating the application of this analysis in biconic structures, an analysis to characterize of the electromagnetic waves in the vacuum feed of the Particle Beam Fusion Accelerator II is provided

  14. Power flow studies of magnetically insulated lines

    International Nuclear Information System (INIS)

    McDaniel, D.H.; Poukey, J.W.; Bergeron, K.D.; VanDevender, J.P.; Johnson, D.L.

    1977-01-01

    The designs for relativistic electron beam accelerators with power levels of 20 to 100 TW are greatly restricted by the inductance of a single diode of reasonable size. This fact leads to modular designs of very large accelerators. One concept uses several small insulators at a large radius arranged around the accelerator center. The total effective inductance is then low, but the energy must then be transported by self-magnetic insulated vacuum lines to the target volume. A triplate vacuum line configuration eases many mechanical support problems and allows more A-K gaps or feeds to be packaged around a given radius. This type of vacuum transmission line was chosen for initial experiments at Sandia. The experiments were conducted on the MITE (Magnetically Insulated Transmission Experiment) accelerator. The water pulse forming lines are connected to a vacuum triplate line through a conventional stacked insulator. Diagnostics on the experiment consisted of: (1) input V; (2) input I; (3) I monitors at the input, middle, and output of both the center conductor and ground plane of the transmission line; (4) magnetic energy analyzer to view peak electron energy in the A-K gap; (5) calorimetry; and (6) Faraday cups to look at electron current flowing across the transmission line. The main goal of the experiment is to obtain input impedance of the transmission line as a function of voltage and to measure electron loss currents. These measurements are compared to theoretical models for the input impedance and energy losses

  15. Using ice melting and ice rolling technologies to remove ice from sub-transmission and transmission lines at Manitoba Hydro

    International Nuclear Information System (INIS)

    Farias, A. R.

    1999-01-01

    Development of an of an Ice Storm Management program by Manitoba Hydro to reduce ice storm damage to its 8 kV feeders to 115 kV transmission lines, is discussed. The program consists of the de-icing of overhead lines, either by ice melting, or ice rolling. Ice melting involves the placement of a three-phase short at a calculated point. The term ice rolling denotes a process of mechanically stripping the ice from conductors. The most recent major ice storm experienced by Manitoba Hydro was in the winter of 1997/1998. During the period from February 6 to February 17, 1998, a total of 83 'ice melt' procedures were performed to melt the ice from 2,628 km of overhead line (7,883 km of conductor), in addition to 'ice rolling'. This paper describes Manitoba Hydro's 25-years' experience with ice melting and it also describes the advantages and disadvantages of both ice melting and ice rolling. Although not a panacea to combat the effects of ice storms, ice melting was found to be the most effective way of removing ice from overhead transmission and sub-transmission lines. Ice rolling was also found to be effective. Other tools that have been found to be useful by various utilities in combating ice storm damage include improved structure and line design, system design that provide more redundancies and emergency sources, and standby generators at critical load points

  16. Analysis of transmission lines loaded with pairs of coupled resonant elements and application to sensors

    International Nuclear Information System (INIS)

    Naqui, J.; Su, L.; Mata, J.; Martín, F.

    2015-01-01

    This paper is focused on the analysis of transmission lines loaded with pairs of magnetically coupled resonators. We have considered two different structures: (i) a microstrip line loaded with pairs of stepped impedance resonators (SIRs), and (ii) a coplanar waveguide (CPW) transmission line loaded with pairs of split ring resonators (SRRs). In both cases, the line exhibits a single resonance frequency (transmission zero) if the resonators are identical (symmetric structure with regard to the line axis), and this resonance is different to the one of the line loaded with a single resonator due to inter-resonator coupling. If the structures are asymmetric, inter-resonator coupling enhances the distance between the two split resonance frequencies that arise. In spite that the considered lines and loading resonators are very different and are described by different lumped element equivalent circuit models, the phenomenology associated to the effects of coupling is exactly the same, and the resonance frequencies are given by identical expressions. The reported lumped element circuit models of both structures are validated by comparing the circuit simulations with extracted parameters with both electromagnetic simulations and experimental data. These structures can be useful for the implementation of microwave sensors based on symmetry properties. - Highlights: • Magnetic-coupling between resonant elements affects transmission properties. • Inter-resonant coupling enhances the distance of two resonant frequencies. • The structures are useful for sensors and comparators, etc

  17. The effects of lightning and high altitude electromagnetic pulse on power distribution lines

    Energy Technology Data Exchange (ETDEWEB)

    Uman, M.A.; Rubinstein, M.; Yacoub, Z. [Florida Univ., Gainesville, FL (United States)

    1995-01-01

    We simultaneously recorded the voltages induced by lightning on both ends of an unenergized 448-meter long unenergized electric power line and the lightning vertical electric and horizontal magnetic fields at ground level near the line. The lightning data studied and presented here were due both to cloud lightning and to very close (about 20 m from the line) artificially initiated lightning. For cloud sources, a frequency-domain computer program called EMPLIN was used to calculate induced line voltages as a function of source elevation, angle of incidence, and wave polarization of the radiated cloud discharge pulses in order to compare with the measurements. For very-close lightning, the measured line voltages could be grouped into two categories, those in which multiple, similarly shaped, evenly spaced pulses were observed, which we call oscillatory, and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which we call impulsive. The amplitude of the induced voltage ranged from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages. A new technique is derived for the calculation of the electromagnetic fields from nearby lightning to ground above an imperfectly conducting ground. This technique was used in conjunction with an existing time domain coupling theory and lightning return stroke model to calculate voltages at either end of the line. The results show fair agreement with the measured oscillatory voltage waveforms if corona is ignored and improved results when corona effects are modeled. The modeling of the impulsive voltage, for which local flashover probably successful. In an attempt to understand better the sources of the line voltages for very close lightning, measurements of the horizontal and vertical electric fields 30 m from triggered lightning were obtained.

  18. Long-Haul Dense Space Division Multiplexed Transmission over Low-Crosstalk Heterogeneous 32-Core Transmission Line Using Partial Recirculating Loop System

    DEFF Research Database (Denmark)

    Mizuno, Takayuki; Shibahara, Kohki; Ye, Feihong

    2017-01-01

    In this paper, we present long-haul 32-core dense space division multiplexed (DSDM) unidirectional transmission over a single-mode multicore transmission line. We developed a low-crosstalk heterogeneous 32-core fiber with a square lattice arrangement, and a novel partial recirculating loop system...

  19. Identification of pulse echo impulse responses for multi source transmission

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jensen, Jørgen Arendt

    2004-01-01

    is a mixture of the information corresponding to several transmitters. There is, thus, no direct way of determining which information corresponds to which transmitter, preventing proper focusing. In this paper we decode the received signal by estimating the pulse echo impulse responses between every....... The method is evaluated using the simulation tool Field II. Three point spread functions are simulated where axial movement of 1 m/s is present. The axial resolution for the moving scatterer is 0.249 mm (-3dB) and 0.291 mm (-6dB), which is compared to a standard STA transmission scheme with sequential...

  20. Development of an accurate transmission line fault locator using the global positioning system satellites

    Science.gov (United States)

    Lee, Harry

    1994-01-01

    A highly accurate transmission line fault locator based on the traveling-wave principle was developed and successfully operated within B.C. Hydro. A transmission line fault produces a fast-risetime traveling wave at the fault point which propagates along the transmission line. This fault locator system consists of traveling wave detectors located at key substations which detect and time tag the leading edge of the fault-generated traveling wave as if passes through. A master station gathers the time-tagged information from the remote detectors and determines the location of the fault. Precise time is a key element to the success of this system. This fault locator system derives its timing from the Global Positioning System (GPS) satellites. System tests confirmed the accuracy of locating faults to within the design objective of +/-300 meters.

  1. Non-Linear Transmission Line (NLTL) Microwave Source Lecture Notes the United States Particle Accelerator School

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven J. [Los Alamos National Laboratory; Carlsten, Bruce E. [Los Alamos National Laboratory

    2012-06-26

    We will quickly go through the history of the non-linear transmission lines (NLTLs). We will describe how they work, how they are modeled and how they are designed. Note that the field of high power, NLTL microwave sources is still under development, so this is just a snap shot of their current state. Topics discussed are: (1) Introduction to solitons and the KdV equation; (2) The lumped element non-linear transmission line; (3) Solution of the KdV equation; (4) Non-linear transmission lines at microwave frequencies; (5) Numerical methods for NLTL analysis; (6) Unipolar versus bipolar input; (7) High power NLTL pioneers; (8) Resistive versus reactive load; (9) Non-lineaer dielectrics; and (10) Effect of losses.

  2. Development of Live-working Robot for Power Transmission Lines

    Science.gov (United States)

    Yan, Yu; Liu, Xiaqing; Ren, Chengxian; Li, Jinliang; Li, Hui

    2017-07-01

    Dream-I, the first reconfigurable live-working robot for power transmission lines successfully developed in China, has the functions of autonomous walking on lines and accurately positioning. This paper firstly described operation task and object of the robot; then designed a general platform, an insulator replacement end and a drainage plate bolt fastening end of the robot, presented a control system of the robot, and performed simulation analysis on operation plan of the robot; and finally completed electrical field withstand voltage tests in a high voltage hall as well as online test and trial on actual lines. Experimental results show that by replacing ends of manipulators, the robot can fulfill operation tasks of live replacement of suspension insulators and live drainage plate bolt fastening.

  3. Data transmission from the DRON-2 X-ray diffractometers to a computer

    International Nuclear Information System (INIS)

    Abramov, V.G.; Monov, N.A.; Sazonov, V.F.; Chernomorskaya, E.A.

    1991-01-01

    The circuit of data transmission from DRON-2 X-ray diffractometer to a measurement-computation complex based on UVK SM-3 computer and CAMAC crate is described. The data is transmitted along two-wire TRP 1x2 telephone line of 'current loop type'. Pulses from intensity channel outlet are transmitted as unipolar mark pulses of ∼1 μs duration. The channels are separated by amplitudes

  4. Comparison of Transmission Line Methods for Surface Acoustic Wave Modeling

    Science.gov (United States)

    Wilson, William; Atkinson, Gary

    2009-01-01

    Surface Acoustic Wave (SAW) technology is low cost, rugged, lightweight, extremely low power and can be used to develop passive wireless sensors. For these reasons, NASA is investigating the use of SAW technology for Integrated Vehicle Health Monitoring (IVHM) of aerospace structures. To facilitate rapid prototyping of passive SAW sensors for aerospace applications, SAW models have been developed. This paper reports on the comparison of three methods of modeling SAWs. The three models are the Impulse Response Method (a first order model), and two second order matrix methods; the conventional matrix approach, and a modified matrix approach that is extended to include internal finger reflections. The second order models are based upon matrices that were originally developed for analyzing microwave circuits using transmission line theory. Results from the models are presented with measured data from devices. Keywords: Surface Acoustic Wave, SAW, transmission line models, Impulse Response Method.

  5. The 12th 735-kV transmission line project: Hydro-Quebec network

    International Nuclear Information System (INIS)

    1992-01-01

    Hydro-Quebec is proposing to construct a 735-kV transmission line from the Chissibi station near the LG3 hydroelectric power plant to the Jacques-Cartier station near Quebec City. The width of the right-of-way will generally be 90 m and it is intended to install the line in two stages. The Chissibi-Chibougamau section should enter service in 1993 and the Chibougamau-Cartier section in 1994. The cost of the line is estimated at $1.21 billion, of which $900 million is for line construction and $310 million for station equipment. Prospective corridors for the line route have been selected, portions of which enable twinning with Hydro-Quebec's existing 9th 735-kV line. A series of hearings on the environmental and other impacts of the power line project was held by the Bureau d'audiences publiques sur l'environnement and results are summarized along with the views of the Bureau. The summary describes the justification for the project, the choice of the transmission line route, the evaluation of the impacts of the project on the natural and human environments, health effects due to magnetic fields, and effects on the economic development of northern Quebec. Recommendations are given for mitigating the impacts of the project. 13 refs., 8 figs., 2 tabs

  6. Preliminary study of steep pulse irreversible electroporation technology in human large cell lung cancer cell lines L9981

    Directory of Open Access Journals (Sweden)

    Song Zuoqing

    2013-01-01

    Full Text Available Our aim was to validate the effectiveness of steep pulse irreversible electroporation technology in human large cell lung cancer cells and to screen the optimal treatment of parameters for human large cell lung cancer cells. Three different sets of steep pulse therapy parameters were applied on the lung cancer cell line L9981. The cell line L9981 inhibition rate and proliferation capacity were detected by Vi-Cell vitality analysis and MTT. Steep pulsed irreversible electroporation technology for large cell lung cancer L9981 presents killing effects with various therapy parameters. The optimal treatment parameters are at a voltage amplitude of 2000V/cm, pulse width of 100μs, pulse frequency of 1 Hz, pulse number 10. With this group of parameters, steep pulse could have the best tumor cell-killing effects.

  7. Stark widths of Xe II lines in a pulsed plasma

    International Nuclear Information System (INIS)

    Djurovic, S; Pelaez, R J; Cirisan, M; Aparicio, J A; Mar, S

    2006-01-01

    In this paper, we present a review of experimental work on Stark broadening of singly ionized xenon lines. Eighty lines, from close UV to the red region of the spectrum, have been studied. Stark halfwidths were compared with experimental data from the literature and modified semi-empirical calculations. A pulsed arc with 95% of helium and 5% xenon was used as a plasma source for this study. Measured electron densities N e and temperatures T were in the ranges of 0.2-1.6 x 10 23 m -3 and 18 300-25 500 K, respectively

  8. Calculation of Voltages in Electric Power Transmission Lines During Historic Geomagnetic Storms: An Investigation Using Realistic Earth Impedances

    Science.gov (United States)

    Lucas, Greg M.; Love, Jeffrey J.; Kelbert, Anna

    2018-02-01

    Commonly, one-dimensional (1-D) Earth impedances have been used to calculate the voltages induced across electric power transmission lines during geomagnetic storms under the assumption that much of the three-dimensional structure of the Earth gets smoothed when integrating along power transmission lines. We calculate the voltage across power transmission lines in the mid-Atlantic region with both regional 1-D impedances and 64 empirical 3-D impedances obtained from a magnetotelluric survey. The use of 3-D impedances produces substantially more spatial variance in the calculated voltages, with the voltages being more than an order of magnitude different, both higher and lower, than the voltages calculated utilizing regional 1-D impedances. During the March 1989 geomagnetic storm 62 transmission lines exceed 100 V when utilizing empirical 3-D impedances, whereas 16 transmission lines exceed 100 V when utilizing regional 1-D impedances. This demonstrates the importance of using realistic impedances to understand and quantify the impact that a geomagnetic storm has on power grids.

  9. Quasi-Optical Transmission Lines for ECRH on TJ-II Stellarator

    International Nuclear Information System (INIS)

    Fernandez, A.; Likin, K.; Martin, R.; Cappa, A.; Cepero, J.R.

    1999-01-01

    Two mirror lines are used to transmit ht microwave power from the powerful microwave generators to the TJ-II plasmas. Both lines have been tested at nominal power level and they are now in operation. This paper is devoted to the final design of the transmission lines and their testing. Before starting operation at high power level measurements of the wave beam parameters at low power level were made. Two horn antennae were designed to simulate the gyrotron output. Numerical simulations of the far field radiation pattern of the antennae were made, a computer code based on Huygens diffraction theory was developed to simulate the propagation of the beam along a mirror line. A comparison of the theoretical and the experimental results is also presented here. (Author)

  10. Construction of a pulsed MeV positron beam line

    Energy Technology Data Exchange (ETDEWEB)

    Masuno, Shin-ichi; Okada, Sohei; Kawasuso, Atsuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    To develop a fast (1 MeV) and short pulsed (100 ps) positron beam which enables defect behavior analysis of bulk states of materials even at high temperatures where a usual positron source would melt, we have been performing design study and construction of the beam line in a three-year program since 1994. This report describes the components, design study results and experimental results of the completed parts until now. (author)

  11. Experimental study of the Fermi–Pasta–Ulam recurrence in a bi-modal electrical transmission line

    International Nuclear Information System (INIS)

    Farota, Abdou K; Faye, Mansour M

    2013-01-01

    We report on the experimental observation of the Fermi–Pasta–Ulam (FPU) recurrence in an experimental bi-modal nonlinear transmission line. The FPU recurrence is observed in the two transmission modes known as the low frequency mode and the high frequency mode. In each case, a spectrum analysis is performed in order to study the waves along the line. (paper)

  12. Characterization of superconducting transmission line resonators

    Energy Technology Data Exchange (ETDEWEB)

    Goetz, Jan; Summer, Philipp; Meier, Sebastian; Haeberlein, Max; Wulschner, Karl Friedrich; Eder, Peter; Fischer, Michael; Schwarz, Manuel; Deppe, Frank; Fedorov, Kirill; Huebl, Hans; Menzel, Edwin [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Krawczyk, Marta; Marx, Achim [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Baust, Alexander; Xie, Edwar; Zhong, Ling; Gross, Rudolf [Walther-Meissner-Institut, Bayerische Akademie der Wissenschaften, Garching (Germany); Physik-Department, TU Muenchen, Garching (Germany); Nanosystems Initiative Munich (NIM), Muenchen (Germany)

    2015-07-01

    Superconducting transmission line resonators are widely used in circuit quantum electrodynamics experiments as quantum bus or storage devices. For these applications, long coherence times, which can be linked to the internal quality factor of the resonators, are crucial. Here, we show a systematic study of the internal quality factor of niobium thin film resonators. We analyze different cleaning methods and substrate parameters for coplanar waveguide as well as microstrip geometries. In addition, we investigate the impact of a niobium-aluminum interface which is necessary for galvanically coupled flux qubits made from aluminum. This interface can be avoided by fabricating the complete resonator-qubit structure using Al/AlO{sub x}/Al technology during fabrication.

  13. Design and performance of the Z magnetically-insulated transmission lines

    International Nuclear Information System (INIS)

    Stygar, W.A.; Spielman, R.B.; Allshouse, G.O.

    1997-01-01

    The 36-module Z accelerator was designed to drive z-pinch loads for weapon-physics and inertial-confinement-fusion experiments, and to serve as a testing facility for pulsed-power research required to develop higher-current drivers. The authors have designed and tested a 10-nH 1.5-m-radius vacuum section for the Z accelerator. The vacuum section consists of four vacuum flares, four conical 1.3-m-radius magnetically-insulated transmission lines, a 7.6-cm-radius 12-post double-post-hole convolute which connects the four outer MITLs in parallel, and a 5-cm-long inner MITL which connects the output of the convolute to a z-pinch load. IVORY and ELECTRO calculations were performed to minimize the inductance of the vacuum flares with the constraint that there be no significant electron emission from the insulator-stack grading rings. Iterative TLCODE calculations were performed to minimize the inductance of the outer MITLs with the constraint that the MITL electron-flow-current fraction be ≤ 7% at peak current. The TLCODE simulations assume a 2.5 cm/micros MITL-cathode-plasma expansion velocity. The design limits the electron dose to the outer-MITL anodes to 50 J/g to prevent the formation of an anode plasma. The TLCODE results were confirmed by SCREAMER, TRIFL, TWOQUICK, IVORY, and LASNEX simulations. For the TLCODE, SCREAMER, and TRIFL calculations, the authors assume that after magnetic insulation is established, the electron-flow current launched in the outer MITLs is lost at the convolute. This assumption has been validated by 3-D QUICKSILVER simulations for load impedances ≤ 0.36 ohms. LASNEX calculations suggest that ohmic resistance of the pinch and conduction-current-induced energy loss to the MITL electrodes can be neglected in Z power-flow modeling that is accurate to first order. To date, the Z vacuum section has been tested on 100 shots. They have demonstrated they can deliver a 100-ns rise-time 20-MA current pulse to the baseline z-pinch load

  14. Influence of nonuniform external magnetic fields and anode--cathode shaping on magnetic insulation in coaxial transmission lines

    International Nuclear Information System (INIS)

    Mostrom, M.A.

    1979-01-01

    Coaxial transmission lines, used to transfer the high voltage pulse into the diode region of a relativistic electron beam generator, have been studied using the two-dimensional time-dependent fully relativistic and electromagnetic particle simulation code CCUBE. A simple theory of magnetic insulation that agrees well with simulation results for a straight cylindrical coax in a uniform external magnetic field is used to interpret the effects of anode--cathode shaping and nonuniform external magnetic fields. Loss of magnetic insulation appears to be minimized by satisfying two conditions: (1) the cathode surface should follow a flux surface of the external magnetic field; (2) the anode should then be shaped to insure that the magnetic insulation impedance, including transients, is always greater than the effective load impedance wherever there is an electron flow in the anode--cathode gap

  15. Project FOOTPRINT: Substation modeling and simulations for E1 pulses

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Scott D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Larson, D. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kirkendall, B. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-11-06

    This report includes a presentation with an: Introduction to CW coupling; Introduction to single-pulse coupling; Description of E1 waveforms; Structures in a substation yard --articulated (as part of the substation's defined electrical functionality)--unarticulated (not as part of the substation's defined electrical functionality); Coupling --electrical coupling (capacitive coupling) --magnetic coupling (inductive coupling); Connectivity to long-line transmission lines; Control infrastructure; Summary; and References.

  16. Proximity effects of high voltage electric power transmission lines on ...

    African Journals Online (AJOL)

    The proximity effects of high voltage electric power transmission lines on Leyland Cypress (xCupressocyparis leylandii (Dallim. and A.B. Jacks.) Dallim) and Japanese Privet (Ligustrum japonicum Thunb.) growth were examined in a private nursery located in Sakarya, Turkey. Five transect were randomly chosen in both ...

  17. Transmission Line Analysis of the Superconducting Quadrupole Chains of the LHC Collider at CERN

    CERN Document Server

    Dahlerup-Petersen, K

    2003-01-01

    Key information for determination of fundamental design features of magnet powering and protection circuits can be retrieved from the results of transmission line calculations of the superconducting magnet chains in a particle accelerator. Modelling and simulation of the behaviour of long magnet strings provide important data for the expected electrical behaviour and performances under all operating conditions. The presented results of a transmission line study concerns the sixteen superconducting main quadrupole chains QF/QD of CERN's future LHC collider. The paper details the elaboration of the synthesized electrical model of the individual quadrupoles and the associated lumped transmission line. It presents results on the current ripple for a given converter voltage output characteristics, the magnet excitation, leakage and earth currents during the ramping procedure, the impedance resonance spectrum and the need for individual magnet damping and the propagation, reflection, superposition and damping of th...

  18. Spatio-temporal imaging of voltage pulses with an ultrafast scanning tunneling microscope

    DEFF Research Database (Denmark)

    Jensen, Jacob Riis; Keil, Ulrich Dieter Felix; Hvam, Jørn Märcher

    1997-01-01

    Measurements on an ultrafast scanning tunneling microscope with simultaneous spatial and temporal resolution are presented. We show images of picosecond pulses propagating on a coplanar waveguide and resolve their mode structures. The influence of transmission line discontinuities on the mode...

  19. Study on Tower Models for EHV Transmission Line

    Directory of Open Access Journals (Sweden)

    Xu Bao-Qing

    2016-01-01

    Full Text Available Lightning outage accident is one of the main factors that threat seriously the safe and reliable operation of power system. So it is very important to establish reasonable transmission tower model and evaluate the impulse response characteristic of lightning wave traveling on the transmission tower properly for determining reliable lightning protection performance. With the help of Electromagnetic Transient Program (EMTP, six 500kV tower models are built. Aiming at one line to one transformer operating mode of 500kV substation, the intruding wave overvoltage under different tower models is calculated. The effect of tower model on intruding overvoltage has been studied. The results show that different tower models can result in great differences to the calculation results. Hence, reasonable selection of the tower model in the calculation of back- strike intruding wave is very important.

  20. Modeling generalized interline power-flow controller (GIPFC using 48-pulse voltage source converters

    Directory of Open Access Journals (Sweden)

    Amir Ghorbani

    2018-05-01

    Full Text Available Generalized interline power-flow controller (GIPFC is one of the voltage-source controller (VSC-based flexible AC transmission system (FACTS controllers that can independently regulate the power-flow over each transmission line of a multiline system. This paper presents the modeling and performance analysis of GIPFC based on 48-pulsed voltage-source converters. This paper deals with a cascaded multilevel converter model, which is a 48-pulse (three levels voltage source converter. The voltage source converter described in this paper is a harmonic neutralized, 48-pulse GTO converter. The GIPFC controller is based on d-q orthogonal coordinates. The algorithm is verified using simulations in MATLAB/Simulink environment. Comparisons between unified power flow controller (UPFC and GIPFC are also included. Keywords: Generalized interline power-flow controller (GIPFC, Voltage source converter (VCS, 48-pulse GTO converter

  1. Calculation of voltages in electric power transmission lines during historic geomagnetic storms: An investigation using realistic earth impedances

    Science.gov (United States)

    Lucas, Greg M.; Love, Jeffrey J.; Kelbert, Anna

    2018-01-01

    Commonly, one-dimensional (1-D) Earth impedances have been used to calculate the voltages induced across electric power transmission lines during geomagnetic storms under the assumption that much of the three-dimensional structure of the Earth gets smoothed when integrating along power transmission lines. We calculate the voltage across power transmission lines in the mid-Atlantic region with both regional 1-D impedances and 64 empirical 3-D impedances obtained from a magnetotelluric survey. The use of 3-D impedances produces substantially more spatial variance in the calculated voltages, with the voltages being more than an order of magnitude different, both higher and lower, than the voltages calculated utilizing regional 1-D impedances. During the March 1989 geomagnetic storm 62 transmission lines exceed 100 V when utilizing empirical 3-D impedances, whereas 16 transmission lines exceed 100 V when utilizing regional 1-D impedances. This demonstrates the importance of using realistic impedances to understand and quantify the impact that a geomagnetic storm has on power grids.

  2. CRPP's Evacuated Waveguide Proposal for JET-EP ECRH Transmission Line

    International Nuclear Information System (INIS)

    Henderson, M. A.; Alberti, S.; Goodman, T. P.; Hogge, J.-P.; Porte, L.; Tran, M. Q.

    2002-01-01

    The goal of this document is to provide a detailed description of the preliminary design and technical information of a proposed evacuated transmission lines for JET . EP ECRH system. Three waveguide diameters (31.75mm, 45mm and 63.5mm) were studied and compared to the base design of the 87mm waveguide/quasi.optical proposal (WG87-QO). This report concentrates on only the 45mm waveguide diameter (WG45). This size represents an optimization between the flexibility of the smaller diameter and the low loss of the larger. For simplicity only the WG45 will be compared with the WG87-QO, but the other diameters (31.75 and 63.5 mm) should be kept under consideration for a final evacuated waveguide line. The characteristics of the 63.5 mm waveguide system can be found in the report which was distributed in September. After an introduction of the history and motivation for this study a general overview of the proposal is presented. Sections 4 and 5 describe the elements to be used in the proposed line including the overall transmission losses for the line. Section 6 offers a cost comparison of the two proposaIs. The 7th section is a brief description of an alternative launcher design using the waveguide inserted into the launcher port. The 8th section describes the ca1ibration and conditioning process to be performed after the line is insta1led and how the torus displacements wi1l be handled. The 9th section describes the proposed schedule for purchasing and insta1lation of the waveguide lines. Sections II and 12 include a conclusion and summary of the proposal. (author)

  3. Mechanical Implementation and Simulation of MoboLab, A Mobile Robot for Inspection of Power Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mahmud Saadat Foumani

    2008-11-01

    Full Text Available This paper describes the first phase in development of a mobile robot that can navigate aerial power transmission lines completely unattended by human operator. Its ultimate purpose is to automate inspection of power transmission lines and their equipments. The authors have developed a scaled functional model of such a mobile robot with a preliminary simple computer based on-off controller. MoboLab (Mobile Laboratory navigates a power transmission line between two strain towers. It can maneuver over obstructions created by line equipments such as insulators, warning spheres, dampers, and spacer dampers. It can also easily negotiate the towers by its three flexible arms. MoboLab has an internal main screw which enables the robot to move itself or its two front and rear arms independently through changing gripped points. When the front arm gets close to an obstacle, the arm detaches from the line and goes down, the robot moves forward, the arm passes the obstacle and grippes the line again. In a same way another arms pass the obstacle.

  4. On increasing the spectral efficiency and transmissivity in the data transmission channel on the spacecraft-ground tracking station line

    Science.gov (United States)

    Andrianov, M. N.; Kostenko, V. I.; Likhachev, S. F.

    2018-01-01

    The algorithms for achieving a practical increase in the rate of data transmission on the space-craft-ground tracking station line has been considered. This increase is achieved by applying spectral-effective modulation techniques, the technology of orthogonal frequency compression of signals using millimeterrange radio waves. The advantages and disadvantages of each of three algorithms have been revealed. A significant advantage of data transmission in the millimeter range has been indicated.

  5. Conducting properties of classical transmission lines with Ornstein-Uhlenbeck type disorder

    International Nuclear Information System (INIS)

    Lazo, E.; Diez, E.

    2011-01-01

    In this work we study the behavior of bands of extended states and localized states which appear in classical disordered electrical transmission lines, when we use a ternary map and the Ornstein-Uhlenbeck process to generate the long-range correlated disorder, instead of using the Fourier filtering method. By performing finite-size scaling we obtain the asymptotic value of the map parameter b in the thermodynamic limit in a selected range of values of the parameters γ and C of the Ornstein-Uhlenbeck process. With these data we obtain the phase diagrams which separate the localized states from the extended states. These are the fundamental results of this article. - Highlights: → We study disordered classical transmission lines. → We use the Ornstein-Uhlenbeck process to generate long-range correlated disorder. → We obtain the phase diagram of the transition in the thermodynamic limit.

  6. Ion diode performance on a positive polarity inductive voltage adder with layered magnetically insulated transmission line flow

    International Nuclear Information System (INIS)

    Hinshelwood, D. D.; Schumer, J. W.; Allen, R. J.; Commisso, R. J.; Jackson, S. L.; Murphy, D. P.; Phipps, D.; Swanekamp, S. B.; Weber, B. V.; Ottinger, P. F.; Apruzese, J. P.; Cooperstein, G.; Young, F. C.

    2011-01-01

    A pinch-reflex ion diode is fielded on the pulsed-power machine Mercury (R. J. Allen, et al., 15th IEEE Intl. Pulsed Power Conf., Monterey, CA, 2005, p. 339), which has an inductive voltage adder (IVA) architecture and a magnetically insulated transmission line (MITL). Mercury is operated in positive polarity resulting in layered MITL flow as emitted electrons are born at a different potential in each of the adder cavities. The usual method for estimating the voltage by measuring the bound current in the cathode and anode of the MITL is not accurate with layered flow, and the interaction of the MITL flow with a pinched-beam ion diode load has not been studied previously. Other methods for determining the diode voltage are applied, ion diode performance is experimentally characterized and evaluated, and circuit and particle-in-cell (PIC) simulations are performed. Results indicate that the ion diode couples efficiently to the machine operating at a diode voltage of about 3.5 MV and a total current of about 325 kA, with an ion current of about 70 kA of which about 60 kA is proton current. It is also found that the layered flow impedance of the MITL is about half the vacuum impedance.

  7. A Pilot Directional Protection for HVDC Transmission Line Based on Relative Entropy of Wavelet Energy

    Directory of Open Access Journals (Sweden)

    Sheng Lin

    2015-07-01

    Full Text Available On the basis of analyzing high-voltage direct current (HVDC transmission system and its fault superimposed circuit, the direction of the fault components of the voltage and the current measured at one end of transmission line is certified to be different for internal faults and external faults. As an estimate of the differences between two signals, relative entropy is an effective parameter for recognizing transient signals in HVDC transmission lines. In this paper, the relative entropy of wavelet energy is applied to distinguish internal fault from external fault. For internal faults, the directions of fault components of voltage and current are opposite at the two ends of the transmission line, indicating a huge difference of wavelet energy relative entropy; for external faults, the directions are identical, indicating a small difference. The simulation results based on PSCAD/EMTDC show that the proposed pilot protection system acts accurately for faults under different conditions, and its performance is not affected by fault type, fault location, fault resistance and noise.

  8. Transmission Delay Modeling of Packet Communication over Digital Subscriber Line

    Directory of Open Access Journals (Sweden)

    Jiri Vodrazka

    2013-01-01

    Full Text Available Certain multimedia and voice services, such as VoIP, IPTV, etc., are significantly delay sensitive and their performance is influenced by the overall transmission delay and its variance. One of the most common solutions used in access networks are xDSL lines, especially ADSL2+ or VDSL2. Although these subscriber lines also use packet communication, there are several differences and mechanisms, which influence their resulting delay. Their delay characteristics are also dependent on the individual settings of each xDSL provider, therefore we decided to investigate this area for typical commercially available lines in Czech Republic. Based on the measured values and experiments with real ADSL2+ lines we also developed a potential modeling method, which is presented in this article as well. The parameters for packet jitter based on the generalized Pareto distribution were modeled.

  9. Bidirectional pulser made from pulse lines for linear induction accelerators

    International Nuclear Information System (INIS)

    Hotta, E.; Mori, T.; Kobayashi, T.; Okino, A.; Haginomori, E.; Ko, K.C.

    1996-01-01

    In order to obtain high-current charged particle beams, linear induction accelerators (LIA's) of two types have been already constructed. Conventional LIA's adopt a unidirectional pulse injected from an external pulser. The other LIA's, one of which has been proposed and constructed by Pavlovskii et al., have accelerating cavities made from pulse forming lines (PFL's). In this case, no magnetic core loaded in the cavity is necessary. However, the injected pulse must be a bidirectional one. Since a part of the voltage pulse with reversed polarity is used to accelerate a beam, it is possible to make the time integral of the output voltage zero. Thus the final magnetic energy stored in the cavity can be made zero at the end of the pulse, and the pulser-accelerator system attains the energy transfer efficiency of 100%. Accelerators of this type can be divided into two kinds, one of which has cavities with internal energy storage, and the other has cavities with energy injected from external bidirectional pulsers. The accelerator of latter type has been first proposed by Smith, but it has not been realized. Several bidirectional pulsers, which consist of three individual PFL's with arbitrary impedances and a closing switch, are analyzed. Output voltages are analytically calculated by using the method proposed by Dommel for digital computations of electromagnetic transients in networks, and conditions for attaining the maximum efficiency of energy transfer from the pulser to the beam are derived. Thus, 4 bidirectional pulsers of internal energy storage type and 2 of external pulse injection type with energy transfer efficiency of 100% are obtained, including the pulsers already reported by other authors

  10. Nanosecond bipolar pulse generators for bioelectrics.

    Science.gov (United States)

    Xiao, Shu; Zhou, Chunrong; Yang, Enbo; Rajulapati, Sambasiva R

    2018-04-26

    Biological effects caused by a nanosecond pulse, such as cell membrane permeabilization, peripheral nerve excitation and cell blebbing, can be reduced or cancelled by applying another pulse of reversed polarity. Depending on the degree of cancellation, the pulse interval of these two pulses can be as long as dozens of microseconds. The cancellation effect diminishes as the pulse duration increases. To study the cancellation effect and potentially utilize it in electrotherapy, nanosecond bipolar pulse generators must be made available. An overview of the generators is given in this paper. A pulse forming line (PFL) that is matched at one end and shorted at the other end allows a bipolar pulse to be produced, but no delay can be inserted between the phases. Another generator employs a combination of a resistor, an inductor and a capacitor to form an RLC resonant circuit so that a bipolar pulse with a decaying magnitude can be generated. A third generator is a converter, which converts an existing unipolar pulse to a bipolar pulse. This is done by inserting an inductor in a transmission line. The first phase of the bipolar pulse is provided by the unipolar pulse's rising phase. The second phase is formed during the fall time of the unipolar pulse, when the inductor, which was previously charged during the flat part of the unipolar pulse, discharges its current to the load. The fourth type of generator uses multiple MOSFET switches stacked to turn on a pre-charged, bipolar RC network. This approach is the most flexible in that it can generate multiphasic pulses that have different amplitudes, delays, and durations. However, it may not be suitable for producing short nanosecond pulses (<100 ns), whereas the PFL approach and the RLC approach with gas switches are used for this range. Thus, each generator has its own advantages and applicable range. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Environmental Assessment and Finding of No Significant Impact: Curecanti-Lost Canyon 230-kV Transmission Line Reroute Project, Montrose County, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    2000-03-20

    The Department of Energy (DOE), Western Area Power Administration (Western) is proposing to reroute a section of the Curecanti-Lost Canyon 230-kilovolt (kV) transmission line, in Montrose County, Colorado. A portion of the transmission line, situated 11 miles southeast of Montrose, Colorado, crosses Waterdog Peak, an area of significant geologic surface activity, which is causing the transmission line's lattice steel towers to shift. This increases stress to structure hardware and conductors, and poses a threat to the integrity of the transmission system. Western proposes to relocate the lattice steel towers and line to a more geologically stable area. The existing section of transmission line and the proposed relocation route cross Bureau of Land Management and private land holdings.

  12. Broadband microwave frequency doubler based on left-handed nonlinear transmission lines

    International Nuclear Information System (INIS)

    Huang Jie; Gu Wenwen; Zhao Qian

    2017-01-01

    A bandwidth microwave second harmonic generator is successfully designed using composite right/left-handed nonlinear transmission lines (CRLH NLTLs) in a GaAs monolithic microwave integrated circuit (MMIC) technology. The structure parameters of CRLH NLTLs, e.g. host transmission line, rectangular spiral inductor, and nonlinear capacitor, have a great impact on the second harmonic performance enhancement in terms of second harmonic frequency, output power, and conversion efficiency. It has been experimentally demonstrated that the second harmonic frequency is determined by the anomalous dispersion of CRLH NLTLs and can be significantly improved by effectively adjusting these structure parameters. A good agreement between the measured and simulated second harmonic performances of Ka-band CRLH NLTLs frequency multipliers is successfully achieved, which further validates the design approach of frequency multipliers on CRLH NLTLs and indicates the potentials of CRLH NLTLs in terms of the generation of microwave and millimeter-wave signal source. (paper)

  13. Sidney-North Yuma 230-kV Transmission Line Project, Colorado and Nebraska

    Energy Technology Data Exchange (ETDEWEB)

    1991-06-01

    This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB)

  14. Pattern decomposition and quantitative-phase analysis in pulsed neutron transmission

    International Nuclear Information System (INIS)

    Steuwer, A.; Santisteban, J.R.; Withers, P.J.; Edwards, L.

    2004-01-01

    Neutron diffraction methods provide accurate quantitative insight into material properties with applications ranging from fundamental physics to applied engineering research. Neutron radiography or tomography on the other hand, are useful tools in the non-destructive spatial imaging of materials or engineering components, but are less accurate with respect to any quantitative analysis. It is possible to combine the advantages of diffraction and radiography using pulsed neutron transmission in a novel way. Using a pixellated detector at a time-of-flight source it is possible to collect 2D 'images' containing a great deal of interesting information in the thermal regime. This together with the unprecedented intensities available at spallation sources and improvements in computing power allow for a re-assessment of the transmission methods. It opens the possibility of simultaneous imaging of diverse material properties such as strain or temperature, as well as the variation in attenuation, and can assist in the determination of phase volume fraction. Spatial and time resolution (for dynamic experiment) are limited only by the detector technology and the intensity of the source. In this example, phase information contained in the cross-section is extracted from Bragg edges using an approach similar to pattern decomposition

  15. Doppler-shifted neutral beam line shape and beam transmission

    International Nuclear Information System (INIS)

    Kamperschroer, J.H.; Grisham, L.R.; Kokatnur, N.; Lagin, L.J.; Newman, R.A.; O'Connor, T.E.; Stevenson, T.N.; von Halle, A.

    1994-04-01

    Analysis of Doppler-shifted Balmer-α line emission from the TFTR neutral beam injection systems has revealed that the line shape is well approximated by the sum of two Gaussians, or, alternatively, by a Lorentzian. For the sum of two Gaussians, the broad portion of the distribution contains 40% of the beam power and has a divergence five times that of the narrow part. Assuming a narrow 1/e- divergence of 1.3 degrees (based on fits to the beam shape on the calorimeter), the broad part has a divergence of 6.9 degrees. The entire line shape is also well approximated by a Lorentzian with a half-maximum divergence of 0.9 degrees. Up to now, fusion neutral beam modelers have assumed a single Gaussian velocity distribution, at the extraction plane, in each direction perpendicular to beam propagation. This predicts a beam transmission efficiency from the ion source to the calorimeter of 97%. Waterflow calorimetry data, however, yield a transmission efficiency of ∼75%, a value in rough agreement with predictions of the Gaussian or Lorentzian models presented here. The broad wing of the two Gaussian distribution also accurately predicts the loss in the neutralizer. An average angle of incidence for beam loss at the exit of the neutralizer is 2.2 degrees, rather than the 4.95 degrees subtended by the center of the ion source. This average angle of incidence, which is used in computing power densities on collimators, is shown to be a function of beam divergence

  16. A Novel Method of Autonomous Inspection for Transmission Line based on Cable Inspection Robot LiDAR Data

    Directory of Open Access Journals (Sweden)

    Xinyan Qin

    2018-02-01

    Full Text Available With the growth of the national economy, there is increasing demand for electricity, which forces transmission line corridors to become structurally complicated and extend to complex environments (e.g., mountains, forests. It is a great challenge to inspect transmission line in these regions. To address these difficulties, a novel method of autonomous inspection for transmission line is proposed based on cable inspection robot (CIR LiDAR data, which mainly includes two steps: preliminary inspection and autonomous inspection. In preliminary inspection, the position and orientation system (POS data is used for original point cloud dividing, ground point filtering, and structured partition. A hierarchical classification strategy is established to identify the classes and positions of the abnormal points. In autonomous inspection, CIR can autonomously reach the specified points through inspection planning. These inspection targets are imaged with PTZ (pan, tilt, zoom cameras by coordinate transformation. The feasibility and effectiveness of the proposed method are verified by test site experiments and actual line experiments, respectively. The proposed method greatly reduces manpower and improves inspection accuracy, providing a theoretical basis for intelligent inspection of transmission lines in the future.

  17. Comparison of ATLOG and Xyce for Bell Labs Electromagnetic Pulse Excitation of Finite-Long Dissipative Conductors over a Ground Plane.

    Energy Technology Data Exchange (ETDEWEB)

    campione, Salvatore [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Warne, Larry K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schiek, Richard [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Basilio, Lorena I. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-09-01

    This report details the modeling results for the response of a finite-length dissipative conductor interacting with a conducting ground to the Bell Labs electromagnetic pulse excitation. We use both a frequency-domain and a time-domain method based on transmission line theory through a code we call ATLOG - Analytic Transmission Line Over Ground. Results are compared to the circuit simulator Xyce for selected cases. Intentionally Left Blank

  18. Adaptive Pulsed Laser Line Extraction for Terrain Reconstruction using a Dynamic Vision Sensor

    Directory of Open Access Journals (Sweden)

    Christian eBrandli

    2014-01-01

    Full Text Available Mobile robots need to know the terrain in which they are moving for path planning and obstacle avoidance. This paper proposes the combination of a bio-inspired, redundancy-suppressing dynamic vision sensor with a pulsed line laser to allow fast terrain reconstruction. A stable laser stripe extraction is achieved by exploiting the sensor’s ability to capture the temporal dynamics in a scene. An adaptive temporal filter for the sensor output allows a reliable reconstruction of 3D terrain surfaces. Laser stripe extractions up to pulsing frequencies of 500Hz were achieved using a line laser of 3mW at a distance of 45cm using an event-based algorithm that exploits the sparseness of the sensor output. As a proof of concept, unstructured rapid prototype terrain samples have been successfully reconstructed with an accuracy of 2mm.

  19. Quantum information generation, storage and transmission based on nuclear spins

    Science.gov (United States)

    Zaharov, V. V.; Makarov, V. I.

    2018-05-01

    A new approach to quantum information generation, storage and transmission is proposed. It is shown that quantum information generation and storage using an ensemble of N electron spins encounter unresolvable implementation problems (at least at the present time). As an alternative implementation we discuss two promising radical systems, one with N equivalent nuclear spins and another with N nonequivalent nuclear spins. Detailed analysis shows that only the radical system containing N nonequivalent nuclei is perfectly matched for quantum information generation, storage and transmission. We develop a procedure based on pulsed electron paramagnetic resonance (EPR) and we apply it to the radical system with the set of nonequivalent nuclei. The resulting EPR spectrum contains 2N transition lines, where N is the number of the atoms with the nuclear spin 1/2, and each of these lines may be encoded with a determined qudit sequence. For encoding the EPR lines we propose to submit the radical system to two magnetic pulses in the direction perpendicular to the z axis of the reference frame. As a result, the radical system impulse response may be measured, stored and transmitted through the communications channel. Confirming our development, the ab initio analysis of the system with three anion radicals was done showing matching between the simulations and the theoretical predictions. The developed method may be easily adapted for quantum information generation, storage, processing and transmission in quantum computing and quantum communications applications.

  20. Rényi entropies of electrical transmission lines with Fibonacci distribution of inductances

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, E., E-mail: elazo@uta.cl [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile); Mellado, F. [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile); Escuela Universitaria de Ingeniería Eléctrica-Electrónica, Universidad de Tarapacá, Arica (Chile); Saavedra, E. [Departamento de Física, Facultad de Ciencias, Universidad de Tarapacá, Arica (Chile)

    2012-10-01

    We study classical dual transmission lines with constant capacitances C{sub j}=C{sub 0}, ∀j, when we distribute two inductance values L{sub A} and L{sub B} according to the Fibonacci sequence. Using the electric current function I{sub j}(ω), we study the normalized localization length Λ(ω), the Rényi entropies R{sub m}(ω) and the normalized information length β(ω). We found three kinds of behavior of the I{sub j}(ω) function: localized, extended and intermediate. In addition, it is found that the transmission line with Fibonacci distribution of inductances shows a behavior characteristic of quasi-periodic systems, namely, a self-similar frequency spectrum, where each subband is divided into three subbands, but the number of global subbands is greater than four.

  1. Plasma-pulse formation and acceleration for fast high-power technology and switching applications

    International Nuclear Information System (INIS)

    Doucet, H.J.; Jones, W.D.; Moustaizis, S.; Lamain, H.; Rouille, C.

    1985-01-01

    A carbon plasma gun powered by a low-inductance capacitor bank and transmission line is used to produce μsec-length pulses of protons having densities of 10/sup 12/-10/sup 14/ cm/sup -3/ at distances of 0.3-1.5 m from the gun and velocities of 10-20 cm/μs. Essential features are a low-inductance surface switch and a nonlinear transmission grid

  2. Pulsed corona generation using a diode-based pulsed power generator

    Science.gov (United States)

    Pemen, A. J. M.; Grekhov, I. V.; van Heesch, E. J. M.; Yan, K.; Nair, S. A.; Korotkov, S. V.

    2003-10-01

    Pulsed plasma techniques serve a wide range of unconventional processes, such as gas and water processing, hydrogen production, and nanotechnology. Extending research on promising applications, such as pulsed corona processing, depends to a great extent on the availability of reliable, efficient and repetitive high-voltage pulsed power technology. Heavy-duty opening switches are the most critical components in high-voltage pulsed power systems with inductive energy storage. At the Ioffe Institute, an unconventional switching mechanism has been found, based on the fast recovery process in a diode. This article discusses the application of such a "drift-step-recovery-diode" for pulsed corona plasma generation. The principle of the diode-based nanosecond high-voltage generator will be discussed. The generator will be coupled to a corona reactor via a transmission-line transformer. The advantages of this concept, such as easy voltage transformation, load matching, switch protection and easy coupling with a dc bias voltage, will be discussed. The developed circuit is tested at both a resistive load and various corona reactors. Methods to optimize the energy transfer to a corona reactor have been evaluated. The impedance matching between the pulse generator and corona reactor can be significantly improved by using a dc bias voltage. At good matching, the corona energy increases and less energy reflects back to the generator. Matching can also be slightly improved by increasing the temperature in the corona reactor. More effective is to reduce the reactor pressure.

  3. Broadband Impedance Transformer Based on Asymmetric Coupled Transmission Lines in Nonhomogeneous Medium

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Krozer, Viktor; Meincke, Peter

    2007-01-01

    A new broadband quarter-wavelength impedance transformer based on an asymmetric coupled line section is presented. The bandwidth of the coupled line transformer is extended with the help of an interconnecting transmission line. An analytical model for the transformer is developed. The analysis...... of the structure reveals that a fractional bandwidth of more than 100% at –20 dB reflection level can be achieved with such a structure. An experimental transformer circuit has been designed, fabricated and tested. Theoretical and experimental results are fair agreement and confirm the established theory...

  4. Line Capacity Expansion and Transmission Switching in Power Systems With Large-Scale Wind Power

    DEFF Research Database (Denmark)

    Villumsen, Jonas Christoffer; Bronmo, Geir; Philpott, Andy B.

    2013-01-01

    In 2020 electricity production from wind power should constitute nearly 50% of electricity demand in Denmark. In this paper we look at optimal expansion of the transmission network in order to integrate 50% wind power in the system, while minimizing total fixed investment cost and expected cost...... of power generation. We allow for active switching of transmission elements to reduce congestion effects caused by Kirchhoff's voltage law. Results show that actively switching transmission lines may yield a better utilization of transmission networks with large-scale wind power and increase wind power...

  5. Study of thermal response of superconducting NbN meander line by using 20 ps pulse laser

    International Nuclear Information System (INIS)

    Miki, Shigehito; Fujiwara, Daisuke; Simakage, Hisashi; Kawakami, Akira; Wang Zhen; Satoh, Kazuo; Yotsuya, Tsutomu; Ishida, Takekazu

    2005-01-01

    The thermal response of a superconducting NbN thin-film meander line was studied by irradiating with a 20 ps pulse laser. A 10 nm-thick NbN thin film was prepared by dc magnetron sputtering and then processed to fabricate a 3 μm-wide, 125.5 mm-long meander line. The device was placed in a 4 K refrigerator, and the bias temperature was kept below the critical temperature T c . The end of an optical fiber was fixed at the front of a meander line, which was then directly irradiated by using the 20 ps pulse laser. The output voltage was observed with a digital oscilloscope and a low-noise amplifier. The output signals of the thermal response were clearly observed

  6. Pulsed power inductive energy storage in the microsecond range

    International Nuclear Information System (INIS)

    Rix, W.; Miller, A.R.; Thompson, J.; Waisman, E.; Wilkinson, M.; Wilson, A.

    1993-01-01

    During the past five years Maxwell has developed a series of inductive energy storage (IES) pulsed power generators; ACE 1, ACE 2, ACE 3, and ACE 4, to drive electron-beam loads. They are all based on a plasma opening switch (POS) contained in a single vacuum envelope operating at conduction times of around one microsecond. They all employ fast capacitor bank technology to match this conduction time without intermediate power conditioning. Oil or air filled transmission lines transfer capacitor bank energy to a vacuum section where the final pulse compression is accomplished. Development of the ACE series is described, emphasizing capacitor bank and the opening switch technology for delivering high voltage, multimegampere pulses to electron beam loads

  7. Big George to Carter Mountain 115-kV transmission line project, Park and Hot Springs Counties, Wyoming. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1994-02-01

    The Western Area Power Administration (Western) is proposing to rebuild, operate, and maintain a 115-kilovolt (kV) transmission line between the Big George and Carter Mountain Substations in northwest Wyoming (Park and Hot Springs Counties). This environmental assessment (EA) was prepared in compliance with the National Environmental Policy Act (NEPA) and the regulations of the Council on Environmental Quality (CEQ) and the Department of Energy (DOE). The existing Big George to Carter Mountain 69-kV transmission line was constructed in 1941 by the US Department of Interior, Bureau of Reclamation, with 1/0 copper conductor on wood-pole H-frame structures without an overhead ground wire. The line should be replaced because of the deteriorated condition of the wood-pole H-frame structures. Because the line lacks an overhead ground wire, it is subject to numerous outages caused by lightning. The line will be 54 years old in 1995, which is the target date for line replacement. The normal service life of a wood-pole line is 45 years. Under the No Action Alternative, no new transmission lines would be built in the project area. The existing 69-kV transmission line would continue to operate with routine maintenance, with no provisions made for replacement.

  8. Cyber Risk Assessment of Transmission Lines in Smart Grids

    Directory of Open Access Journals (Sweden)

    Xuan Liu

    2015-12-01

    Full Text Available The increasing use of information technologies in power systems has increased the risk of power systems to cyber-attacks. In this paper, we assess the risk of transmission lines being overloaded due to cyber-based false data injection attacks. The cyber risk assessment is formulated as bilevel optimization problems that determine the maximum line flows under false data injection attacks. We propose efficient techniques to reduce the computation complexity of solving the bilevel problems. Specifically, primary and secondary filtering techniques are employed to identify the lines whose flows will never exceed their limits, which can significantly reduce computation burden. A special feasibility cut-based acceleration technique is introduced to further reduce the computation burden. The simulation results on the IEEE 30-bus, IEEE 118-bus, IEEE 300-bus and IEEE 2383-bus systems verify the proposed risk assessment model and the effectiveness of the proposed filtering and acceleration techniques.

  9. Using technique vibration diagnostics for assessing the quality of power transmission line supports repairs

    Directory of Open Access Journals (Sweden)

    Cherpakov Aleksander

    2017-01-01

    Full Text Available The considered method for assessing the quality of the repair work to restore the rack supports of transmission lines is based on the method of vibration diagnostics. Power transmission line supports with a symmetrical destruction of the protective layer of concrete in the ground in violation of the construction section were chosen as an object. Finite element modelling package Ansys was used in assessing the quality of repair work. The example of evaluating the quality of repair using the relative adhesion defective area design criteria in the analysis of natural vibration frequencies is given.

  10. Controlling the transmission line shape of molecular t-stubs and potential thermoelectric applications

    DEFF Research Database (Denmark)

    Stadler, Robert; Markussen, Troels

    2011-01-01

    Asymmetric line shapes can occur in the transmission function describing electron transport in the vicinity of a minimum caused by quantum interference effects. Such asymmetry can be used to increase the thermoelectric efficiency of molecular junctions. So far, however, asymmetric line shapes hav...... calculations for a variety of t-stub molecules and also address their suitability for thermoelectric applications....

  11. Equipment for data transmission from scintillation detectors and motion scintiaraph to multichannel analyzer or computer

    International Nuclear Information System (INIS)

    Runczik, I.; Cernoch, V.

    1981-01-01

    The patent is claimed for the connection of the equipment. By its positional output the data selection circuit is connected to the input of a program counter and by its time output to the input of a time analyzer. A pulse tape recorder is connected to the input of the selection circuit. The equipment may be used off-line and on-line. In the on-line mode the data are fed directly to the selection circuit, in the off-line mode they are recorded on a tape of the pulse tape recorder and then fed to the selection data circuit. The selection data circuit classifies data into time and positional depending on the type of information. Control circuits increase the reliability of data transmission. (J.P.)

  12. Fiber Bragg Grating Sensor for Fault Detection in Radial and Network Transmission Lines

    Directory of Open Access Journals (Sweden)

    Mehdi Shadaram

    2010-10-01

    Full Text Available In this paper, a fiber optic based sensor capable of fault detection in both radial and network overhead transmission power line systems is investigated. Bragg wavelength shift is used to measure the fault current and detect fault in power systems. Magnetic fields generated by currents in the overhead transmission lines cause a strain in magnetostrictive material which is then detected by Fiber Bragg Grating (FBG. The Fiber Bragg interrogator senses the reflected FBG signals, and the Bragg wavelength shift is calculated and the signals are processed. A broadband light source in the control room scans the shift in the reflected signal. Any surge in the magnetic field relates to an increased fault current at a certain location. Also, fault location can be precisely defined with an artificial neural network (ANN algorithm. This algorithm can be easily coordinated with other protective devices. It is shown that the faults in the overhead transmission line cause a detectable wavelength shift on the reflected signal of FBG and can be used to detect and classify different kind of faults. The proposed method has been extensively tested by simulation and results confirm that the proposed scheme is able to detect different kinds of fault in both radial and network system.

  13. Lumped transmission line avalanche pulser

    Science.gov (United States)

    Booth, Rex

    1995-01-01

    A lumped linear avalanche transistor pulse generator utilizes stacked transistors in parallel within a stage and couples a plurality of said stages, in series with increasing zener diode limited voltages per stage and decreasing balanced capacitance load per stage to yield a high voltage, high and constant current, very short pulse.

  14. Effects of Electron Flow Current Density on Flow Impedance of Magnetically Insulated Transmission Lines

    International Nuclear Information System (INIS)

    He Yong; Zou Wen-Kang; Song Sheng-Yi

    2011-01-01

    In modern pulsed power systems, magnetically insulated transmission lines (MITLs) are used to couple power between the driver and the load. The circuit parameters of MITLs are well understood by employing the concept of flow impedance derived from Maxwell's equations and pressure balance across the flow. However, the electron density in an MITL is always taken as constant in the application of flow impedance. Thus effects of electron flow current density (product of electron density and drift velocity) in an MITL are neglected. We calculate the flow impedances of an MITL and compare them under three classical MITL theories, in which the electron density profile and electron flow current density are different from each other. It is found that the assumption of constant electron density profile in the calculation of the flow impedance is not always valid. The electron density profile and the electron flow current density have significant effects on flow impedance of the MITL. The details of the electron flow current density and its effects on the operation impedance of the MITL should be addressed more explicitly by experiments and theories in the future. (nuclear physics)

  15. Cross Talk Analysis on Multiple Coupled Transmission Lines; (The calculation of transfer functions on multiple coupled tansmission lines in an inhomogeneous dielectric medium)

    DEFF Research Database (Denmark)

    Dalby, Arne Brejning

    1994-01-01

    A flow graph relating voltages and the forward and reflected propagation modes (¿ TEM) on multiple coupled transmission lines in an inhomogeneous dielectric medium is presented. This flow graph directy gives the different transfer functions, including S-parameters, in matrix form needed to calcul......A flow graph relating voltages and the forward and reflected propagation modes (¿ TEM) on multiple coupled transmission lines in an inhomogeneous dielectric medium is presented. This flow graph directy gives the different transfer functions, including S-parameters, in matrix form needed...

  16. Broadband THz pulse emission and transmission properties of nanostructured Pt thin films

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Mingzhe [Department of Physics and Electronics, Liupanshui Normal University, Liupanshui, Guizhou 553004 (China); College of Electronics and Information, Guizhou University, Huaxi 550025, Guiyang, Guizhou (China); Mu, Kaijun; Zhang, Cunlin [Department of Physics, Capital Normal University, Yuquan Road 100082, Beijing (China); Gu, Haoshuang, E-mail: guhs@hubu.edu.cn [Department of Electronic Sci& Tech, Hubei University, Xueyuan Road 430062, Wuhan, Hubei (China); Ding, Zhao [College of Electronics and Information, Guizhou University, Huaxi 550025, Guiyang, Guizhou (China)

    2015-10-01

    The THz transmission and emitting properties of a composite metallic nanostructure, composed of Ag nanowires electrodeposited in an anodic aluminum oxide (AAO) template and a Pt thin film, were investigated by using a femtosecond pulse laser irradiation. The microstructure of the above sub-wavelength nanostructure was investigated by XRD, SEM, AFM and TEM. The results indicated that the thickness of the Pt thin film was about 200 nm and the Ag nanowire array had a sparse and random distribution inside the AAO template, with a length distribution in the range of 10–25 μm. The THz radiation properties of above sub-wavelength nanostructure indicated that the generated THz fluence from the Pt film was a magnitude of μW scale with a broadband frequency range and its subsequent transmission could be significantly improved by the better impedance matching property of the Ag nanowire embedded AAO film compared with that of the empty AAO film.

  17. Development of 700 pps high-duty-cycle line-type pulse modulator

    Energy Technology Data Exchange (ETDEWEB)

    Baba, H.; Satoh, K.; Miura, A. [NIHON KOSHUHA Co., LTD., Yokohama, Kanagawa (Japan)] [and others

    1997-04-01

    The high-duty-cycle line-type pulse modulator has been developed to drive the 5.5 MW S-band klystron at the 700 pps maximum repetition-rate and the 14 {mu}sec flat-top pulse-width. To keep an enough recovery time to the thyratron-tube, the command charging scheme was adopted. To do this, a charging SCR-bank has been developed, which is capable of handling the peak charging current of 50 A. The system achieved the world wide highest average output-power of 205 kW. Two modulators have been installed in a new high-duty-cycle electron linear accelerator, which has been started its business operation in March 1996 as an electron-beam-sterilization facility. (J.P.N)

  18. Experimental observation on asymmetric energy flux within the forbidden frequency band in the LC transmission line

    International Nuclear Information System (INIS)

    Tao Feng; Chen Weizhong; Pan Junting; Xu Wen; Du Sidan

    2012-01-01

    We study the energy flux in a nonlinear electrical transmission line consisting of two coupled segments which are identical in structure and different in parameters. The asymmetry of energy flux caused by nonlinear wave has been observed experimentally in the forbidden band of the line. The experiment shows whether the energy can flow through the transmission line depends on the amplitude of the boundary driving voltages, which can be well explained in the theoretical framework of nonlinear supratransmission. The numerical simulation based on Kirchhoff’s laws further verifies the existence of the asymmetric energy flux in the forbidden band.

  19. Study of a phase-to-ground fault on a 400 kV overhead transmission line

    Science.gov (United States)

    Iagăr, A.; Popa, G. N.; Diniş, C. M.

    2018-01-01

    Power utilities need to supply their consumers at high power quality level. Because the faults that occur on High-Voltage and Extra-High-Voltage transmission lines can cause serious damages in underlying transmission and distribution systems, it is important to examine each fault in detail. In this work we studied a phase-to-ground fault (on phase 1) of 400 kV overhead transmission line Mintia-Arad. Indactic® 650 fault analyzing system was used to record the history of the fault. Signals (analog and digital) recorded by Indactic® 650 were visualized and analyzed by Focus program. Summary of fault report allowed evaluation of behavior of control and protection equipment and determination of cause and location of the fault.

  20. A Ku-band magnetically insulated transmission line oscillator with overmoded slow-wave-structure

    Science.gov (United States)

    Jiang, Tao; He, Jun-Tao; Zhang, Jian-De; Li, Zhi-Qiang; Ling, Jun-Pu

    2016-12-01

    In order to enhance the power capacity, an improved Ku-band magnetically insulated transmission line oscillator (MILO) with overmoded slow-wave-structure (SWS) is proposed and investigated numerically and experimentally. The analysis of the dispersion relationship and the resonant curve of the cold test indicate that the device can operate at the near π mode of the TM01 mode, which is useful for mode selection and control. In the particle simulation, the improved Ku-band MILO generates a microwave with a power of 1.5 GW and a frequency of 12.3 GHz under an input voltage of 480 kV and input current of 42 kA. Finally, experimental investigation of the improved Ku-band MILO is carried out. A high-power microwave (HPM) with an average power of 800 MW, a frequency of 12.35 GHz, and pulse width of 35 ns is generated under a diode voltage of 500 kV and beam current of 43 kA. The consistency between the experimental and simulated far-field radiation pattern confirms that the operating mode of the improved Ku-band MILO is well controlled in π mode of the TM01 mode. Project supported partly by the National Natural Science Foundation of China (Grant No. 61171021).

  1. On-line nuclear ash gauge for coal based on gamma-ray transmission techniques

    International Nuclear Information System (INIS)

    Rizk, R.A.M.; El-Kateb, A.H.; Abdul-Kader, A.M.

    1999-01-01

    Developments and applications of on-line nuclear gauges in the coal industry are highly requested. A nuclear ash gauge for coal, based on γ-ray transmission techniques is developed. Single and dual energy γ-ray beams are used to determine the ash content of coal. The percentage ash content as a function of the γ-ray intensities transmitted through coal samples is measured and sensitivity curves are obtained. An empirical formulation relating the ash content values to the γ-ray intensities is derived. Preliminary results show that both single and dual energy γ-ray transmission techniques can be used to give a rapid on-line estimation of the ash concentration values in coal with low cost and reasonable accuracy, but the dual one is much preferable. (author)

  2. Experimental analysis of a TEM plane transmission line for DNA studies at 900 MHz EM fields

    International Nuclear Information System (INIS)

    Belloni, F; Doria, D; Lorusso, A; Nassisi, V; Velardi, L; Alifano, P; Monaco, C; Tala, A; Tredici, M; Raino, A

    2006-01-01

    A suitable plane transmission line was developed and its behaviour analysed at 900 MHz radiofrequency fields to study DNA mutability and the repair of micro-organisms. In this work, utilizing such a device, we investigated the behaviour of DNA mutability and repair of Escherichia coli strains. The transmission line was very simple and versatile in changing its characteristic resistance and field intensity by varying its sizes. In the absence of cell samples inside the transmission line, the relative modulation of the electric and/or magnetic field was ±31% with respect to the mean values, allowing the processing of more samples at different exposure fields in a single run. A slight decrease in spontaneous mutability to rifampicin-resistance of the E. coli JC411 strain was demonstrated in mismatch-repair proficient samples exposed to the radio-frequency fields during their growth on solid medium

  3. Transmission line sag calculations using interval mathematics

    Energy Technology Data Exchange (ETDEWEB)

    Shaalan, H. [Institute of Electrical and Electronics Engineers, Washington, DC (United States)]|[US Merchant Marine Academy, Kings Point, NY (United States)

    2007-07-01

    Electric utilities are facing the need for additional generating capacity, new transmission systems and more efficient use of existing resources. As such, there are several uncertainties associated with utility decisions. These uncertainties include future load growth, construction times and costs, and performance of new resources. Regulatory and economic environments also present uncertainties. Uncertainty can be modeled based on a probabilistic approach where probability distributions for all of the uncertainties are assumed. Another approach to modeling uncertainty is referred to as unknown but bounded. In this approach, the upper and lower bounds on the uncertainties are assumed without probability distributions. Interval mathematics is a tool for the practical use and extension of the unknown but bounded concept. In this study, the calculation of transmission line sag was used as an example to demonstrate the use of interval mathematics. The objective was to determine the change in cable length, based on a fixed span and an interval of cable sag values for a range of temperatures. The resulting change in cable length was an interval corresponding to the interval of cable sag values. It was shown that there is a small change in conductor length due to variation in sag based on the temperature ranges used in this study. 8 refs.

  4. Lagrangian and Hamiltonian Formulation of Transmission Line Systems with Boundary Energy Flow

    NARCIS (Netherlands)

    Jeltsema, Dimitri; Schaft, Arjan J. van der

    The classical Lagrangian and Hamiltonian formulation of an electrical transmission line is reviewed and extended to allow for varying boundary conditions, The method is based on the definition of an infinite-dimensional analogue of the affine Lagrangian and Hamiltonian input-output systems

  5. Advanced materials for the optical delay line of frequency pulse modulator on the basis of semiconductor laser

    International Nuclear Information System (INIS)

    Abrarov, S.M.

    1999-01-01

    In the paper some materials which can be sued as an optical delay line of the pulse frequency modulator are considered. The structure and the principle are described as a modulator consisting of a laser diode with two Fabry Perot resonators and an optical wave guide providing a feedback loop. The optical wave guide fulfills the function of delay line and links the two resonators. The pulse sequence of the radiation of the semiconductor laser arises due to failure and recovery of optical generation. The pulse frequency modulation can be carried out by the action of electrical tension field on the electro optic martial of the wave guide. The selection of three electro-optic crystals for making of the optical wave guide of the considered modulator is justified. (author)

  6. Minimal inductance for axisymmetric transmission lines with radially dependent anode-cathode gap

    Directory of Open Access Journals (Sweden)

    Eduardo M. Waisman

    2009-09-01

    Full Text Available We extend the variational calculus technique for inductance minimization of constant gap axisymmetric transmission lines (TL, introduced by Hurricane [J. Appl. Phys. 95, 4503 (2004JAPIAU0021-897910.1063/1.1687986], to the case in which the anode-cathode gap is a linear function of the midgap radius. The full analytic optimal midgap solution curve z(r yielding minimum inductance is obtained in terms of a single parameter ρ_{0}, determined numerically by imposing that z(r goes through prescribed end points. The radius of curvature ρ(r of the optimal curve is obtained everywhere the function is defined, even outside of the end point range, and it is shown that a convenient choice is ρ_{0}=ρ(0. The value of the transmission line inductance is calculated by 1D numerical quadrature. A simple numerical technique is introduced for TL with nonlinear radial gap dependence.

  7. Shielding Effectiveness Analysis and Modification of the Coupling Effect Transmission Line Method on Cavities with Multi-Sided Apertures

    Directory of Open Access Journals (Sweden)

    Tao Hu

    2018-04-01

    Full Text Available Because the traditional transmission line method treats electromagnetic waves as excitation sources and the cavity as a rectangular waveguide whose terminal is shorted, the transmission line method can only calculate shielding effectiveness in the center line of the cavity with apertures on one side. In this paper, the aperture coupling effect of different sides was analyzed based on vector analysis. According to the field intensity distribution of different transport modes in the rectangular waveguide, the calculation model of cavity shielding effectiveness in any position is proposed, which can solve the question of the calculation model of shielding effectiveness in any position in the traditional method of equivalent transmission methods. Further expansion of the equivalent transmission lines model is adopted to study the shielding effectiveness of different aperture cavities, and the coupling effect rule of the incident angle, the number of apertures, and the size of the cavity is obtained, which can provide the technical support for the design of electromagnetic shielding cavities for electronic equipment.

  8. Assessment of surge arrester failure rate and application studies in Hellenic high voltage transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Christodoulou, C.A.; Fotis, G.P.; Gonos, I.F.; Stathopulos, I.A. [National Technical University of Athens, School of Electrical and Computer Engineering, High Voltage Laboratory, 9 Iroon Politechniou St., Zografou Campus, 157 80 Athens (Greece); Ekonomou, L. [A.S.PE.T.E. - School of Pedagogical and Technological Education, Department of Electrical Engineering Educators, N. Heraklion, 141 21 Athens (Greece)

    2010-02-15

    The use of transmission line surge arresters to improve the lightning performance of transmission lines is becoming more common. Especially in areas with high soil resistivity and ground flash density, surge arresters constitute the most effective protection mean. In this paper a methodology for assessing the surge arrester failure rate based on the electrogeometrical model is presented. Critical currents that exceed arresters rated energy stress were estimated by the use of a simulation tool. The methodology is applied on operating Hellenic transmission lines of 150 kV. Several case studies are analyzed by installing surge arresters on different intervals, in relation to the region's tower footing resistance and the ground flash density. The obtained results are compared with real records of outage rate showing the effectiveness of the surge arresters in the reduction of the recorded failure rate. The presented methodology can be proved valuable to the studies of electric power systems designers intending in a more effective lightning protection, reducing the operational costs and providing continuity of service. (author)

  9. 55-TW magnetically insulated transmission-line system: Design, simulations, and performance

    Directory of Open Access Journals (Sweden)

    W. A. Stygar

    2009-12-01

    Full Text Available We describe herein a system of self-magnetically insulated vacuum transmission lines (MITLs that operated successfully at 20 MA, 3 MV, and 55 TW. The system delivered the electromagnetic-power pulse generated by the Z accelerator to a physics-package load on over 1700 Z shots. The system included four levels that were electrically in parallel. Each level consisted of a water flare, vacuum-insulator stack, vacuum flare, and 1.3-m-radius conical outer MITL. The outputs of the four outer MITLs were connected in parallel by a 7.6-cm-radius 12-post double-post-hole vacuum convolute. The convolute added the currents of the four outer MITLs, and delivered the combined current to a single 6-cm-long inner MITL. The inner MITL delivered the current to the load. The total initial inductance of the stack-MITL system was 11 nH. A 300-element transmission-line-circuit model of the system has been developed using the tl code. The model accounts for the following: (i impedance and electrical length of each of the 300 circuit elements, (ii electron emission from MITL-cathode surfaces wherever the electric field has previously exceeded a constant threshold value, (iii Child-Langmuir electron loss in the MITLs before magnetic insulation is established, (iv MITL-flow-electron loss after insulation, assuming either collisionless or collisional electron flow, (v MITL-gap closure, (vi energy loss to MITL conductors operated at high lineal current densities, (vii time-dependent self-consistent inductance of an imploding z-pinch load, and (viii load resistance, which is assumed to be constant. Simulations performed with the tl model demonstrate that the nominal geometric outer-MITL-system impedance that optimizes overall performance is a factor of ∼3 greater than the convolute-load impedance, which is consistent with an analytic model of an idealized MITL-load system. Power-flow measurements demonstrate that, until peak current, the Z stack-MITL system

  10. Sound transmission through double panel constructions lined with elastic porous materials

    Science.gov (United States)

    Bolton, J. S.; Green, E. R.

    1986-07-01

    Attention is given to a theory governing one-dimensional wave motion in elastic porous materials which is capable of reproducing experimental transmission measurements for unfaced polyurethane foam layers. Calculations of the transmission loss of fuselage-like foam-lined double panels are presented and it is shown that the foam/panel boundary conditions have a large effect on the panel performance; a hybrid arrangement whereby the foam is bonded directly to one panel and separated from the other by a thin air gap appears to be the most advantageous under practical circumstances. With this configuratiom, the mass-air-mass resonance is minimized and increased low-frequency performance is offered.

  11. System for Relay Protection Command Transmission by High-Voltage Lines

    Directory of Open Access Journals (Sweden)

    D. A. Yenkov

    2009-01-01

    Full Text Available Development of a system for relay protection command transmission by high-voltage lines is shown in the paper. The paper describes an architecture of the system, main principles of its operation, engineering aspects of the development that is accomplishment of technical requirements, solution of trades-off. Justification of the selected design and an algorithm of the reliable detection of relay protection signals are given in the paper.

  12. Induced voltages in metallic pipelines near power transmission lines

    International Nuclear Information System (INIS)

    Grcev, Leonid; Jankov, Voislav; Filiposki, Velimir

    2002-01-01

    With the continuous development of the electric power system and the pipeline networks used to convey oil or natural gas, cases of close proximity of high voltage structures and metallic pipelines become more and more frequent. Accordingly there is a growing concern about possible hazards resulting from voltages induced in the metallic pipelines by magnetic coupling with nearby power transmission lines. This paper presents a methodology for computation of the induced voltages in buried isolated metallic pipelines. A practical example of computation is also presented. (Author)

  13. Alleviation SSR and Low Frequency Power Oscillations in Series Compensated Transmission Line using SVC Supplementary Controllers

    Science.gov (United States)

    Kumar, Sanjiv; Kumar, Narendra

    2017-06-01

    In this work, supplementary sub-synchronous damping controllers (SSDC) are proposed for damping sub-synchronous oscillations in power systems with series compensated transmission lines. Series compensation have extensively been used as effective means of increasing the power transfer capability of a transmission lines and improving transient stability limits of power systems. Series compensation with transmission lines may cause sub-synchronous resonance (SSR). The eigenvalue investigation tool is used to ascertain the existence of SSR. It is shown that the addition of supplementary controller is able to stabilize all unstable modes for T-network model. Eigenvalue investigation and time domain transient simulation of detailed nonlinear system are considered to investigate the performance of the controllers. The efficacies of the suggested supplementary controllers are compared on the IEEE first benchmark model for computer simulations of SSR by means of time domain simulation in Matlab/Simulink environment. Supplementary SSDC are considered in order to compare effectiveness of SSDC during higher loading in alleviating the small signal stability problem.

  14. Seismic Response of Power Transmission Tower-Line System Subjected to Spatially Varying Ground Motions

    Directory of Open Access Journals (Sweden)

    Li Tian

    2010-01-01

    Full Text Available The behavior of power transmission tower-line system subjected to spatially varying base excitations is studied in this paper. The transmission towers are modeled by beam elements while the transmission lines are modeled by cable elements that account for the nonlinear geometry of the cables. The real multistation data from SMART-1 are used to analyze the system response subjected to spatially varying ground motions. The seismic input waves for vertical and horizontal ground motions are also generated based on the Code for Design of Seismic of Electrical Installations. Both the incoherency of seismic waves and wave travel effects are accounted for. The nonlinear time history analytical method is used in the analysis. The effects of boundary conditions, ground motion spatial variations, the incident angle of the seismic wave, coherency loss, and wave travel on the system are investigated. The results show that the uniform ground motion at all supports of system does not provide the most critical case for the response calculations.

  15. Fuzzy-Wavelet Based Double Line Transmission System Protection Scheme in the Presence of SVC

    Science.gov (United States)

    Goli, Ravikumar; Shaik, Abdul Gafoor; Tulasi Ram, Sankara S.

    2015-06-01

    Increasing the power transfer capability and efficient utilization of available transmission lines, improving the power system controllability and stability, power oscillation damping and voltage compensation have made strides and created Flexible AC Transmission (FACTS) devices in recent decades. Shunt FACTS devices can have adverse effects on distance protection both in steady state and transient periods. Severe under reaching is the most important problem of relay which is caused by current injection at the point of connection to the system. Current absorption of compensator leads to overreach of relay. This work presents an efficient method based on wavelet transforms, fault detection, classification and location using Fuzzy logic technique which is almost independent of fault impedance, fault distance and fault inception angle. The proposed protection scheme is found to be fast, reliable and accurate for various types of faults on transmission lines with and without Static Var compensator at different locations and with various incidence angles.

  16. Transmission of laser pulses with high output beam quality using step-index fibers having large cladding

    Science.gov (United States)

    Yalin, Azer P; Joshi, Sachin

    2014-06-03

    An apparatus and method for transmission of laser pulses with high output beam quality using large core step-index silica optical fibers having thick cladding, are described. The thick cladding suppresses diffusion of modal power to higher order modes at the core-cladding interface, thereby enabling higher beam quality, M.sup.2, than are observed for large core, thin cladding optical fibers. For a given NA and core size, the thicker the cladding, the better the output beam quality. Mode coupling coefficients, D, has been found to scale approximately as the inverse square of the cladding dimension and the inverse square root of the wavelength. Output from a 2 m long silica optical fiber having a 100 .mu.m core and a 660 .mu.m cladding was found to be close to single mode, with an M.sup.2=1.6. Another thick cladding fiber (400 .mu.m core and 720 .mu.m clad) was used to transmit 1064 nm pulses of nanosecond duration with high beam quality to form gas sparks at the focused output (focused intensity of >100 GW/cm.sup.2), wherein the energy in the core was laser pulses was about 6 ns. Extending the pulse duration provided the ability to increase the delivered pulse energy (>20 mJ delivered for 50 ns pulses) without damaging the silica fiber.

  17. Scenario calculations for the 2012 grid development plan. Overdimensioned HVDC transmission lines; Szenarienrechnungen zum Netzentwicklungsplan (NEP) 2012. HGUe-Leitungen ueberdimensioniert

    Energy Technology Data Exchange (ETDEWEB)

    Oei, Pao-Yu; Sander, Aram; Hankel, Lisa; Laurisch, Lilian; Lorenz, Casimir [Technische Univ. Berlin (Germany); Schroeder, Andreas [Deutsches Institut fuer Wirtschaftsforschung, Berlin (Germany)

    2012-09-15

    The grid development plan presented in June 2012 by the German Federal Network Agency envisages a large number of new AC and DC transmission lines for Germany. The purpose of these transmission lines is to facilitate the point-to-point transport of electricity produced from renewable resources to load centres. The authors present a model-assisted analysis of the impact of these transmission lines on the structure of electricity production. They also investigate to what extent an increase in storage capacity and the steering of demand can serve as alternatives to grid expansion.

  18. Nonlinear left-handed transmission line metamaterials

    International Nuclear Information System (INIS)

    Kozyrev, A B; Weide, D W van der

    2008-01-01

    Metamaterials, exhibiting simultaneously negative permittivity ε and permeability μ, more commonly referred to as left-handed metamaterials (LHMs) and also known as negative-index materials, have received substantial attention in the scientific and engineering communities [1]. Most studies of LHMs (and electromagnetic metamaterials in general) have been in the linear regime of wave propagation and have already inspired new types of microwave circuits and devices. The results of these studies have already been the subject of numerous reviews and books. This review covers a less explored but rapidly developing area of investigation involving media that combine nonlinearity (dependence of the permittivity and permeability on the magnitude of the propagating field) with the anomalous dispersion exhibited by LHM. The nonlinear phenomena in such media will be considered on the example of a model system: the nonlinear left-handed transmission line. These nonlinear phenomena include parametric generation and amplification, harmonic and subharmonic generation as well as modulational instabilities and envelope solitons. (topical review)

  19. Transmission of reactive pulsed laser deposited VO{sub 2} films in the THz domain

    Energy Technology Data Exchange (ETDEWEB)

    Émond, Nicolas; Hendaoui, Ali; Ibrahim, Akram; Al-Naib, Ibraheem; Ozaki, Tsuneyuki; Chaker, Mohamed, E-mail: chaker@emt.inrs.ca

    2016-08-30

    Highlights: • Synthesis of vanadium dioxide (VO{sub 2}) thin films as a function of oxygen pressure (2–25 mTorr) using Reactive Pulsed Laser Deposition (RPLD). • Characterization of RPLD-grown VO{sub 2} thin films in the THz frequency range. • THz switches and/or sensors require VO{sub 2} films deposited at low oxygen pressure (i.e. low transition temperature, large amplitude contrast of THz transmission, narrow hysteresis width). • THz optical memory applications require VO{sub 2} films deposited at high oxygen pressure (broad hysteresis width). - Abstract: This work reports on the characteristics of the insulator-to-metal transition (IMT) of reactive pulsed laser deposited vanadium dioxide (VO{sub 2}) films in the terahertz (THz) frequency range, namely the transition temperature T{sub IMT}, the amplitude contrast of the THz transmission over the IMT ΔA, the transition sharpness ΔT and the hysteresis width ΔH. XRD analysis shows the sole formation of VO{sub 2} monoclinic structure with an enhancement of (011) preferential orientation when varying the O{sub 2} pressure (P{sub O2}) during the deposition process from 2 to 25 mTorr. THz transmission measurements as a function of temperature reveal that VO{sub 2} films obtained at low P{sub O2} exhibit low T{sub IMT}, large ΔA, and narrow ΔH. Increasing P{sub O2} results in VO{sub 2} films with higher T{sub IMT}, smaller ΔA, broader ΔH and asymmetric hysteresis loop. The good control of the VO{sub 2} IMT features in the THz domain could be further exploited for the development of advanced smart devices, such as ultrafast switches, modulators, memories and sensors.

  20. A simple sub-nanosecond ultraviolet light pulse generator with high repetition rate and peak power.

    Science.gov (United States)

    Binh, P H; Trong, V D; Renucci, P; Marie, X

    2013-08-01

    We present a simple ultraviolet sub-nanosecond pulse generator using commercial ultraviolet light-emitting diodes with peak emission wavelengths of 290 nm, 318 nm, 338 nm, and 405 nm. The generator is based on step recovery diode, short-circuited transmission line, and current-shaping circuit. The narrowest pulses achieved have 630 ps full width at half maximum at repetition rate of 80 MHz. Optical pulse power in the range of several hundreds of microwatts depends on the applied bias voltage. The bias voltage dependences of the output optical pulse width and peak power are analysed and discussed. Compared to commercial UV sub-nanosecond generators, the proposed generator can produce much higher pulse repetition rate and peak power.

  1. Sensitive detection of chlorine in iron oxide by single pulse and dual pulse laser-induced breakdown spectroscopy

    Science.gov (United States)

    Pedarnig, J. D.; Haslinger, M. J.; Bodea, M. A.; Huber, N.; Wolfmeir, H.; Heitz, J.

    2014-11-01

    The halogen chlorine is hard to detect in laser-induced breakdown spectroscopy (LIBS) mainly due to its high excited state energies of 9.2 and 10.4 eV for the most intense emission lines at 134.72 nm and 837.59 nm, respectively. We report on sensitive detection of Cl in industrial iron oxide Fe2O3 powder by single-pulse (SP) and dual-pulse (DP) LIBS measurements in the near infrared range in air. In compacted powder measured by SP excitation (Nd:YAG laser, 532 nm) Cl was detected with limit of detection LOD = 440 ppm and limit of quantitation LOQ = 720 ppm. Orthogonal DP LIBS was studied on pressed Fe2O3 pellets and Fe3O4 ceramics. The transmission of laser-induced plasma for orthogonal Nd:YAG 1064 nm and ArF 193 nm laser pulses showed a significant dependence on interpulse delay time (ipd) and laser wavelength (λL). The UV pulses (λL = 193 nm) were moderately absorbed in the plasma and the Cl I emission line intensity was enhanced while IR pulses (λL = 1064 nm) were not absorbed and Cl signals were not enhanced at ipd = 3 μs. The UV laser enhancement of Cl signals is attributed to the much higher signal/background ratio for orthogonal DP excitation compared to SP excitation and to the increased plasma temperature and electron number density. This enabled measurement at a very short delay time of td ≥ 0.1 μs with respect to the re-excitation pulse and detection of the very rapidly decaying Cl emission with higher efficiency.

  2. Multiband Slot-Based Dual Composite Right/Left-Handed Transmission Line

    Directory of Open Access Journals (Sweden)

    E. Abdo-Sanchez

    2012-10-01

    Full Text Available A dual Composite Right-/Left-Handed Transmission Line (CRLH TL implementation that presents multiband behaviour is proposed in this contribution. The artificial TL is realized by loading a host microstrip line with alternate rectangular stubs and slots. The required series and shunt immittances are respectively provided by the slot and the stub. Due to the distributed nature of these immittances, the resultant phase response presents theoretically infinite RH and LH alternate bands, thus being appropriate for multiband applications. The design methodology is described with the help of a proposed TLs-based equivalent circuit and highlights the simplicity for balance condition. Full wave simulated results of the dispersion characteristics and frequency response of a unit-cell and a three-cells structure are presented.

  3. Electrostatic induction under the Tanashi test transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Kitani, Y; Yokata, S

    1964-06-01

    Experimental results are given on the electrostatic voltage induced in small and medium-sized motorcars under the Tanashi 800 kV Test Transmission Line, which is of horizontal arrangement, 200 m span, four bundle conductors and average height of 13.52 m. The induced voltage was measured between 1600 and 3000 V under the line voltage of 520 kV. The voltage and current were measured with four kinds of model motorcars in air and water, and results of the measurements are compared with those of actual measurements with good agreements. The values of capacity and leakage resistance, whose parallel circuit was considered to represent an equivalent circuit of the motorcar, were measured with a Maxwell-Wien bridge at frequencies between 30 and 1000 c/s. It was found that the values at 60 c/s were measured to be approximately six or seven times higher than its values at 1000 c/s, and that new tires have higher conductivities than the old ones, reducing the electrostatic induction voltage by a large amount.

  4. Generalized transmission line method to study the far-zone radiation of antennas under a multilayer structure

    CERN Document Server

    Wu, Xuan Hui

    2008-01-01

    This book gives a step-by-step presentation of a generalized transmission line method to study the far-zone radiation of antennas under a multilayer structure. Normally, a radiation problem requires a full wave analysis which may be time consuming. The beauty of the generalized transmission line method is that it transforms the radiation problem for a specific type of structure, say the multilayer structure excited by an antenna, into a circuit problem that can be efficiently analyzed. Using the Reciprocity Theorem and far-field approximation, the method computes the far-zone radiation due to

  5. Ultrashort pulse energy distribution for propulsion in space

    Science.gov (United States)

    Bergstue, Grant Jared

    This thesis effort focuses on the development of a novel, space-based ultrashort pulse transmission system for spacecraft. The goals of this research include: (1) ultrashort pulse transmission strategies for maximizing safety and efficiency; (2) optical transmission system requirements; (3) general system requirements including control techniques for stabilization; (4) optical system requirements for achieving effective ablative propulsion at the receiving spacecraft; and (5) ultrashort pulse transmission capabilities required for future missions in space. A key element of the research is the multiplexing device required for aligning the ultrashort pulses from multiple laser sources along a common optical axis for transmission. This strategy enables access to the higher average and peak powers required for useful missions in space.

  6. Conceptual design of a 10^{13}-W pulsed-power accelerator for megajoule-class dynamic-material-physics experiments

    Directory of Open Access Journals (Sweden)

    W. A. Stygar

    2016-07-01

    Full Text Available We have developed a conceptual design of a next-generation pulsed-power accelerator that is optimized for megajoule-class dynamic-material-physics experiments. Sufficient electrical energy is delivered by the accelerator to a physics load to achieve—within centimeter-scale samples—material pressures as high as 1 TPa. The accelerator design is based on an architecture that is founded on three concepts: single-stage electrical-pulse compression, impedance matching, and transit-time-isolated drive circuits. The prime power source of the accelerator consists of 600 independent impedance-matched Marx generators. Each Marx comprises eight 5.8-GW bricks connected electrically in series, and generates a 100-ns 46-GW electrical-power pulse. A 450-ns-long water-insulated coaxial-transmission-line impedance transformer transports the power generated by each Marx to a system of twelve 2.5-m-radius water-insulated conical transmission lines. The conical lines are connected electrically in parallel at a 66-cm radius by a water-insulated 45-post sextuple-post-hole convolute. The convolute sums the electrical currents at the outputs of the conical lines, and delivers the combined current to a single solid-dielectric-insulated radial transmission line. The radial line in turn transmits the combined current to the load. Since much of the accelerator is water insulated, we refer to it as Neptune. Neptune is 40 m in diameter, stores 4.8 MJ of electrical energy in its Marx capacitors, and generates 28 TW of peak electrical power. Since the Marxes are transit-time isolated from each other for 900 ns, they can be triggered at different times to construct–over an interval as long as 1  μs–the specific load-current time history required for a given experiment. Neptune delivers 1 MJ and 20 MA in a 380-ns current pulse to an 18-mΩ load; hence Neptune is a megajoule-class 20-MA arbitrary waveform generator. Neptune will allow the international

  7. Stress Analysis of Boom of Special Mobile Crane for Plain Region in Transmission Line

    Science.gov (United States)

    Qin, Jian; Shao, Tao; Chen, Jun; Wan, Jiancheng; Li, Zhonghuan; Jiang, Ming

    2017-10-01

    Basis of the boom force analysis of special mobile crane for plain region in transmission line, the load type of boom design is confirmed. According to the different combinations of boom sections, the composite pattern of the different boom length is obtained to suit the actual conditions of boom overlapping. The large deformation model is employed with FEM to simulate the stress distribution of boom, and the calculation results are checked. The performance curves of rated load with different arm length and different working range are obtained, which ensures the lifting capacity of special mobile crane meeting the requirement of tower erection of transmission line. The proposed FEM of boom of mobile crane would provide certain guiding and reference to the boom design.

  8. Analysis of lightning fault detection, location and protection on short and long transmission lines using Real Time Digital Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Andre Luiz Pereira de [Siemens Ltda., Sao Paulo, SP (Brazil)], E-mail: andreluiz.oliveira@siemens.com

    2007-07-01

    The purpose of this paper is to present an analysis of lightning fault detection, location and protection using numeric distance relays applied in high voltage transmission lines, more specifically in the 500 kV transmission lines of CEMIG (Brazilian Energy Utility) between the Vespasiano 2 - Neves 1 (short line - 23.9 km) and Vespasiano 2 - Mesquita (long line - 148.6 km) substations. The analysis was based on the simulations results of numeric distance protective relays on power transmission lines, realized in September 02 to 06, 2002, at Siemens AG's facilities (Erlangen - Germany), using Real Time Digital Simulator (RTDS{sup TM}). Several lightning faults simulations were accomplished, in several conditions of the electrical power system where the protective relays would be installed. The results are presented not only with the times of lightning faults elimination, but also all the functionality of a protection system, including the correct detection, location and other advantages that these modern protection devices make possible to the power system. (author)

  9. Program for the analysis of pulse height spectra and the background from a proportional detector

    International Nuclear Information System (INIS)

    Flores-Llamas, H.; Yee-Madeira, H.; Contreras-Puente, G.; Zamorano-Ulloa, R.

    1991-01-01

    A PC-Fortran program is presented for fitting of lineshapes and the analysis of pulse height spectra obtainable with proportional detectors. The common fitting and analysis of pulse height spectra by means of mixed Gaussian lineshapes is readily improved by using Voigt lineshapes. In addition, the background can be evaluated during the fitting process without the need of extra measurements. As an application of the program, a pulse height transmission spectrum accumulated with a static 57 Co source and detected with an argon-metane proportional detector, was least squares fitted to an elaborated complex trial lineshape function containing two Voigt lines plus a straight line. The fitting straight line parameters a and b characterize quantitatively the background. The very good PC-fitting obtained shows that the fitting of experimental spectra with the more realistic Voigt lineshapes is no longer a formidable task and that it is possible to evaluate and subtract the background inherent to the experiment during the fitting process. (orig.)

  10. Definition of a matrix of the generalized parameters asymmetrical multiphase transmission lines

    Directory of Open Access Journals (Sweden)

    Suslov V.M.

    2005-12-01

    Full Text Available Idle time, without introduction of wave characteristics, algorithm of definition of a matrix of the generalized parameters asymmetrical multiphase transmission lines is offered. Definition of a matrix of parameters is based on a matrix primary specific of parameters of line and simple iterative procedure. The amount of iterations of iterative procedure is determined by a set error of performance of the resulted matrix ratio between separate blocks of a determined matrix. The given error is connected by close image of with a margin error determined matrix.

  11. Wild Horse 69-kV transmission line environmental assessment

    International Nuclear Information System (INIS)

    1996-12-01

    Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline's pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE's review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest

  12. Wild Horse 69-kV transmission line environmental assessment

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline`s pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE`s review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest.

  13. Transmission line model for coupled rectangular double split‐ring resonators

    DEFF Research Database (Denmark)

    Yan, Lei; Tang, Meng; Krozer, Viktor

    2011-01-01

    In this work, a model based on a coupled transmission line formulation is developed for microstrip rectangular double split‐ring resonators (DSRRs). This model allows using the physical dimensions of the DSRRs as an input avoiding commonly used extraction of equivalent parameters. The model inclu...... simulations of the DSRR structures. © 2011 Wiley Periodicals, Inc. Microwave Opt Technol Lett 53:1311–1315, 2011; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.25988...

  14. Sound transmission through triple-panel structures lined with poroelastic materials

    OpenAIRE

    Liu, Y

    2015-01-01

    In this paper, previous theories on the prediction of sound transmission loss for a double-panel structure lined with poroelastic materials are extended to address the problem of a triple-panel structure. Six typical configurations are considered for a triple-panel structure based on the method of coupling the porous layers to the facing panels which determines critically the sound insulation performance of the system. The transfer matrix method is employed to solve the system by applying app...

  15. Calculation of large ion densities under HVdc transmission lines by the finite difference method

    International Nuclear Information System (INIS)

    Suda, Tomotaka; Sunaga, Yoshitaka

    1995-01-01

    A calculation method for large ion densities (charged aerosols) under HVdc transmission lines was developed considering both the charging mechanism of aerosols by small ions and the drifting process by wind. Large ion densities calculated by this method agreed well with the ones measured under the Shiobara HVdc test line on the lateral profiles at ground level up to about 70m downwind from the line. Measured values decreased more quickly than calculated ones farther downwind from the line. Considering the effect of point discharge from ground cover (earth corona) improved the agreement in the farther downwind region

  16. Technical and economic data for overhead lines in high-voltage a. c. and d. c. transmission

    Energy Technology Data Exchange (ETDEWEB)

    1977-11-01

    For the study of 'High-power electricity transmission and distribution in densely populated areas' technical and economic data were compiled for high-voltage alternating current and direct current transmission. A modification of the overhead lines for transmitting higher powers is possible as required by means of higher rated transmission voltages, larger conductor cross-sections and a larger number of circuits installed on each mast. For the use of larger partial conductor cross-sections and of bundle conductors with more than 4 partial conductors, and also to use voltages higher than 380 kV, development work is requisite from the points of view of construction, installation, insulators and fittings. Further possible developments result from the use of new materials such as plastic insulators which make possible the use of more versatile shapes for application in heavy pollution, particulary for direct current overhead lines. By using insulating crossarms the width of path can be considerably reduced. Economic efficiency investigations show even today higher cost for such techniques compared with lines of earlier construction.

  17. DEVELOPMENT AND INVESTIGATION OF LAYOUT OF ACTIVE SCREENING SYSTEM OF THE MAGNETIC FIELD GENERATED BY GROUP OF OVERHEAD TRANSMISSION LINES

    Directory of Open Access Journals (Sweden)

    B. I. Kuznetsov

    2018-04-01

    Full Text Available Purpose. Development and field experimental research of layout of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area is given. Methodology. Mathematical model of magnetic field, generated by group of high voltage transmission lines in residential area, based of the experimental values of magnetic field flux density in given points on the basis of optimization problem solving is improved. The objective of the synthesis of the single circuit active screening system is to determine their number, configuration, spatial arrangement, wiring diagrams and compensation cables currents, setting algorithm of the control systems as well as the resulting value of the magnetic flux density at the points of the protected space. Synthesis of the full-scale model of active screening system is reduced to the problem of multiobjective nonlinear programming with constraints in which calculation of the objective functions and constraints are carried out on the basis of the Maxwell equations solutions in the quasi-stationary approximation. The problem is solved by a stochastic multiswarm multi-agent particles optimization. Results. The single-circuit active screening system synthesis results for reduction of a magnetic field generated by group of high voltage transmission lines in residential area is given. Field experimental researches of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area with various control algorithms is given. Originality. For the first time out the development and field experimental studies of the single-circuit active screening system of the magnetic field generated by group of high voltage transmission lines in residential area are carried out. Practical value. Practical recommendations on reasonable choice of the spatial arrangement of compensating cables of single

  18. Temporal characterization of short-pulse third-harmonic generation in an atomic gas by a transmission-grating Michelson interferometer.

    Science.gov (United States)

    Papadogiannis, N A; Nersisyan, G; Goulielmakis, E; Rakitzis, T P; Hertz, E; Charalambidis, D; Tsakiris, G D; Witte, K

    2002-09-01

    By use of a transmission-grating-based Michelson interferometer, second-order interferometric as well as intensity autocorrelation traces of the third harmonic of a Ti:sapphire 50-fs laser beam produced in Ar have been measured. The duration of the harmonic is found to be that expected from lowest-order perturbation theory. At this wavelength, the performance of the interferometer with respect to pulse-front distortion and dispersion is found to be satisfactory. This result is a first step toward the use of the interferometer for the temporal characterization of higher harmonics or harmonic superposition forming attosecond pulse trains.

  19. Continuous single pulse resolved measurement of beam diameters at 200 kHz using optical transmission filters

    Science.gov (United States)

    Fruechtenicht, Johannes; Letsch, Andreas; Voss, Andreas; Abdou Ahmed, Marwan; Graf, Thomas

    2012-02-01

    We present a novel laser beam measurement setup which allows the determination of the beam diameter for each single pulse of a pulsed laser beam at repetition rates of up to 200 kHz. This is useful for online process-parameter control e.g. in micromachining or for laser source characterization. Basically, the developed instrument combines spatial transmission filters specially designed for instantaneous optical determination of the second order moments of the lateral intensity distribution of the light beam and photodiodes coupled to customized electronics. The acquisition is computer-based, enabling real-time operation for online monitoring or control. It also allows data storage for a later analysis and visualization of the measurement results. The single-pulse resolved beam diameter can be measured and recorded without any interruption for an unlimited number of pulses. It is only limited by the capacity of the data storage means. In our setup a standard PC and hard-disk provided 2 hours uninterrupted operation and recording of varying beam diameters at 200 kHz. This is about three orders of magnitude faster than other systems. To calibrate our device we performed experiments in cw and pulsed regimes and the obtained results were compared to those obtained with a commercial camera based system. Only minor deviations of the beam diameter values between the two instruments were observed, proving the reliability of our approach.

  20. Inductive line energy storage generator

    Energy Technology Data Exchange (ETDEWEB)

    Choi, P [Ecole Polytechnique, Palaiseau (France). Laboratoire de Physique des Milieux Ionises

    1997-12-31

    The inductive energy storage (IES) generator has long been considered to be the most efficient system for energy usage in large pulsed power system at the MA level. A number of parameters govern the efficiency of energy transfer between the storage capacitors and the load, and the level of current deliverable to the load. For high power system, the energy storage capacitors are arranged as a Marx generator. The primary constraints are the inductances in the various parts of the circuit, in particular, the upstream inductance between the Marx and the POS, and the downstream inductance between the POS and the load. This paper deals with the effect of replacing part of the upstream inductance with a transmission line and introduces the new concept of an inductive line for energy storage (ILES). Extensive parametric scans were carried out on circuit simulations to investigate the effect of this upstream transmission line. A model was developed to explain the operation of the ILES design based on the data obtained. Comparison with an existing IES generator shows that the ILES design offers a significant improvement in the maximum current and hence energy delivered to an inductive load. (author). 5 figs., 1 ref.

  1. Quality factor of a transmission line coupled coplanar waveguide resonator

    Energy Technology Data Exchange (ETDEWEB)

    Besedin, Ilya [National University for Science and Technology (MISiS), Moscow (Russian Federation); National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation); Menushenkov, Alexey P. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2018-12-15

    We investigate analytically the coupling of a coplanar waveguide resonator to a coplanar waveguide feedline. Using a conformal mapping technique we obtain an expression for the characteristic mode impedances and coupling coefficients of an asymmetric multi-conductor transmission line. Leading order terms for the external quality factor and frequency shift are calculated. The obtained analytical results are relevant for designing circuit-QED quantum systems and frequency division multiplexing of superconducting bolometers, detectors and similar microwave-range multi-pixel devices. (orig.)

  2. Fractional analysis for nonlinear electrical transmission line and nonlinear Schroedinger equations with incomplete sub-equation

    Science.gov (United States)

    Fendzi-Donfack, Emmanuel; Nguenang, Jean Pierre; Nana, Laurent

    2018-02-01

    We use the fractional complex transform with the modified Riemann-Liouville derivative operator to establish the exact and generalized solutions of two fractional partial differential equations. We determine the solutions of fractional nonlinear electrical transmission lines (NETL) and the perturbed nonlinear Schroedinger (NLS) equation with the Kerr law nonlinearity term. The solutions are obtained for the parameters in the range (0<α≤1) of the derivative operator and we found the traditional solutions for the limiting case of α =1. We show that according to the modified Riemann-Liouville derivative, the solutions found can describe physical systems with memory effect, transient effects in electrical systems and nonlinear transmission lines, and other systems such as optical fiber.

  3. A 350 KV nanosecond pulse voltage generator with adjustable pulsed-width

    International Nuclear Information System (INIS)

    Wang, X.; Wang, M.; Chen, Y.Q.; Zeng, L.G.; Han, M.

    2002-01-01

    This paper presents a 350 kV nanosecond pulse voltage generator (NPVG). The voltage pulsed-width can be adjusted from 30 to 160 ns. The generator consists of: Marx generator, pulsed forming line (PFL), main switch and matched impedance. The output voltage of Marx generator is over than nU c (n- the stage number of Marx generator, U c -the charging voltage of capacitor). When the pulse forming line is terminated with an impedance that is over than the characteristic impedance of PFL, the higher voltage pulse was provided for the load

  4. Planning Electric Transmission Lines: A Review of Recent Regional Transmission Plans

    Energy Technology Data Exchange (ETDEWEB)

    Eto, Joseph H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-04-13

    The first Quadrennial Energy Review (QER) recommends that the U.S. Department of Energy (DOE) conduct a national review of transmission plans and assess the barriers and incentives to their implementation. DOE tasked Lawrence Berkeley National Laboratory (LBNL) to prepare two reports to support the agency’s response to this recommendation. This report reviews regional transmission plans and regional transmission planning processes that have been directed by Federal Energy Regulatory Commission (FERC) Order Nos. 890 and 1000. We focus on the most recent regional transmission plans (those issued in 2015 and through approximately mid-year 2016) and current regional transmission planning processes. A companion report focuses on non-plan-related factors that affect transmission projects.

  5. Review of fire behavior during passage of Sandy Lake Fire 13 (NWT) across a Northwest Territories Power Corporation transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, D.; Thomasson, J.

    2009-03-15

    The Sandy Lake Fire 13 of July 2008 was an intense forest fire that burned up to and across a power line right-of-way in the Northwest Territories, approximately 160 km northwest of Fort Smith. The terrain in the area is flat and vegetation is characterized by boreal pine and black spruce uplands with black spruce and tamarack in lower areas and adjacent to wetlands. This report documented post fire conditions at locations where the fire crossed the power line. The towers on this line were made from an aluminum alloy and may not have had the same resistance to heat damage as steel towers, more commonly used on major transmission lines. The transmission line was de-energized during the fire. Therefore, the effects of fire on power transmission were not documented. Although the intense wildfire crossed sections of the power line, it did not result in observable damage to the towers or lines. Fire intensity was likely greater than 40,000 kw/m along some sections of the right-of-way. Although the management of the right-of-way may have reduced heat exposure to the transmission towers, it did not stop the fire. Pine mixed with an aspen component greater than 50 per cent had a mitigating effect on fire behaviour. The fire did not result in any immediate damage to the power line infrastructure. It was concluded that the use of power lines for fire operations should consider right-of-way width in order to assess equipment maneuverability, especially around tower guy wires. 5 refs., 1 tab., 12 figs.

  6. New neutron imaging using pulsed sources. Characteristics of a pulsed neutron source and principle of pulsed neutron imaging

    International Nuclear Information System (INIS)

    Kiyanagi, Yoshiaki

    2012-01-01

    Neutron beam is one of important tools to obtain the transmission image of an object. Until now, steady state neutron sources such as reactors are mainly used for this imaging purpose. Recently, it has been demonstrated that pulsed neutron imaging based on accelerator neutron sources can provide a real-space distribution of physical information of materials such as crystallographic structure, element, temperature, hydrogen bound state, magnetic field and so on, by analyzing wavelength dependent transmission spectrum, which information cannot be observed or difficult to obtain with a traditional imaging method using steady state neutrons. Here, characteristics of the pulsed neutron source and principle of the pulsed neutron imaging are explained as a basic concept of the new method. (author)

  7. Effect of a superconducting coil as a fault current limiter on current density distribution in BSCCO tape after an over-current pulse

    International Nuclear Information System (INIS)

    Tallouli, M; Yamaguchi, S.; Shyshkin, O.

    2017-01-01

    The development of power transmission lines based on long-length high temperature superconducting (HTS) tapes is complicated and technically challenging task. A serious problem for transmission line operation could become HTS power cable damage due to over-current pulse conditions. To avoid the cable damage in any urgent case the superconducting coil technology, i.e. superconductor fault current limiter (SFCL) is required. Comprehensive understanding of the current density characteristics of HTS tapes in both cases, either after pure over-current pulse or after over-current pulse limited by SFCL, is needed to restart or to continue the operation of the power transmission line. Moreover, current density distribution along and across the HTS tape provides us with the sufficient information about the quality of the tape performance in different current feeding regimes. In present paper we examine BSCCO HTS tape under two current feeding regimes. The first one is 100A feeding preceded by 900A over-current pulse. In this case none of tape protection was used. The second scenario is similar to the fist one but SFCL is used to limit an over-current value. For both scenarios after the pulse is gone and the current feeding is set up at 100A we scan magnetic field above the tape by means of Hall probe sensor. Then the feeding is turned of and the magnetic field scanning is repeated. Using the inverse problem numerical solver we calculate the corresponding direct and permanent current density distributions during the feeding and after switch off. It is demonstrated that in the absence of SFCL the current distribution is highly peaked at the tape center. At the same time the current distribution in the experiment with SFCL is similar to that observed under normal current feeding condition. The current peaking in the first case is explained by the effect of an opposite electric field induced at the tape edges during the overcurrent pulse decay, and by degradation of

  8. Implementation of a microcomputer based distance relay for parallel transmission lines

    International Nuclear Information System (INIS)

    Phadke, A.G.; Jihuang, L.

    1986-01-01

    Distance relaying for parallel transmission lines is a difficult application problem with conventional phase and ground distance relays. It is known that for cross-country faults involving dissimilar phases and ground, three phase tripping may result. This paper summarizes a newly developed microcomputer based relay which is capable of classifying the cross-country fault correctly. The paper describes the principle of operation and results of laboratory tests of this relay

  9. Overhead Transmission Lines Deicing under Different Incentive Displacement

    Directory of Open Access Journals (Sweden)

    Qing He

    2014-01-01

    Full Text Available Overhead transmission line icing is one of the main factors affecting safety and reliability of power grid. This paper proposed an excitation deicing method of iced wire and theoretically revealed the ice removal mechanism under displacement excitation conditions, by taking the LGJ-70/10 glaze icing wire as the 3D model and analyzing and studying its dynamic response under the effect of displacement excitation. The simulation results show that the stress of wire icing area is enlarged with the increase of excitation displacement and frequency. Through the comparison of the compression strength experimental results on a series of different iced wires in low temperature environment, the authors found out that the stress generated from the wire icing area is greater than the crushing strength of the ice within the scope of the calculation parameters, which proved the validity and the feasibility of the method, and finally the suitable excitation displacement is determined. Following studies show that, as far as possible, it is necessary to reduce the incentive displacement and also to select the appropriate constraint length in order to avoid the line jumping that may be caused by large span ice shedding.

  10. Thermal analysis of a transmission line for Traveling Wave Tube TWT

    International Nuclear Information System (INIS)

    Chbiki, Mounir; Laraqi, Najib; Jarno, Jean-François; Herrewyn, Jacques; Silva Botelho, Tony da

    2012-01-01

    A new analytical method has been developed to study the delay line of Traveling Waves Tubes (TWT). Our study is focused on the analysis of the hot lines shrinking phenomenon. In the studied case, unlike brazed configuration, the contact areas are not perfect, resulting in a diminution of the heat transfer process. In this work, we highlight the influence of the macro-constriction on the heat transfer rate in the various parts of a TWT the geometry of which is also relatively complex. We propose in this work an analytical study of the thermal behavior of a transmission line in established regime. First, we determine the individual thermal resistance of each component. Secondly, we estimate the global resistance of the device according to the geometrical parameters and the respective conductivities of the various elements of this line. In this analytical model, we proceed to parametric studies in order to determine the geometrical configurations that will provide the lowest global thermal resistance. We will emphasize the potential gain according to the used materials and the increase of contact areas.

  11. PROTO-II: a short pulse water insulated accelerator

    International Nuclear Information System (INIS)

    Martin, T.H.; VanDevender, J.P.; Johnson, D.L.; McDaniel, D.H.; Aker, M.

    1975-01-01

    A new accelerator, designated Proto-II, is presently under construction at Sandia Laboratories. Proto-II will have a nominal output of 100 kJ into a two-sided diode at a voltage of 1.5 MV and a total current of over 6 MA for 24 ns. This accelerator will be utilized for electron beam fusion experiments and for pulsed power and developmental studies leading to a proposed further factor of five scale-up in power. The design of Proto-II is based upon recent water switching developments and represents a 10-fold extrapolation of those results. Initial testing of Proto-II is scheduled to begin in 1976. Proto-II power flow starts with eight Marx generators which charge 16 water-insulated storage capacitors. Eight triggered, 3 MV, SF 6 gas-insulated switches next transfer the energy through oil-water interfaces into the first stage of 16 parallel lines. Next, the 16 first stages transfer their energy into the pulse forming lines and fast switching sections.The energy is then delivered to two converging, back-to-back, disk-shaped transmission line. Two back-to-back diodes then form the electron beams which are focused onto a common anode

  12. Adjustable direct current and pulsed circuit fault current limiter

    Science.gov (United States)

    Boenig, Heinrich J.; Schillig, Josef B.

    2003-09-23

    A fault current limiting system for direct current circuits and for pulsed power circuit. In the circuits, a current source biases a diode that is in series with the circuits' transmission line. If fault current in a circuit exceeds current from the current source biasing the diode open, the diode will cease conducting and route the fault current through the current source and an inductor. This limits the rate of rise and the peak value of the fault current.

  13. Time-dependent H-like and He-like Al lines produced by ultra-short pulse laser

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Takako; Kato, Masatoshi [National Inst. for Fusion Science, Nagoya (Japan); Shepherd, R; Young, B; More, R; Osterheld, Al

    1998-03-01

    We have performed numerical modeling of time-resolved x-ray spectra from thin foil targets heated by the LLNL Ultra-short pulse (USP) laser. The targets were aluminum foils of thickness ranging from 250 A to 1250 A, heated with 120 fsec pulses of 400 nm light from the USP laser. The laser energy was approximately 0.2 Joules, focused to a 3 micron spot size for a peak intensity near 2 x 10{sup 19} W/cm{sup 2}. Ly{alpha} and He{alpha} lines were recorded using a 900 fsec x-ray streak camera. We calculate the effective ionization, recombination and emission rate coefficients including density effects for H-like and He-like aluminum ions using a collisional radiative model. We calculate time-dependent ion abundances using these effective ionization and recombination rate coefficients. The time-dependent electron temperature and density used in the calculation are based on an analytical model for the hydrodynamic expansion of the target foils. During the laser pulse the target is ionized. After the laser heating stops, the plasma begins to recombine. Using the calculated time dependent ion abundances and the effective emission rate coefficients, we calculate the time dependent Ly{alpha} and He{alpha} lines. The calculations reproduce the main qualitative features of the experimental spectra. (author)

  14. Evaluation of Fibre Lifetime in Optical Ground Wire Transmission Lines

    Science.gov (United States)

    Grunvalds, R.; Ciekurs, A.; Porins, J.; Supe, A.

    2017-06-01

    In the research, measurements of polarisation mode dispersion of two OPGWs (optical ground wire transmission lines), in total four fibres, have been carried out, and the expected lifetime of the infrastructure has been assessed on the basis of these measurements. The cables under consideration were installed in 1995 and 2011, respectively. Measurements have shown that polarisation mode dispersion values for cable installed in 1995 are four times higher than that for cable installed in 2011, which could mainly be explained by technological differences in fibre production and lower fibre polarisation mode dispersion requirements in 1995 due to lack of high-speed (over 10 Gbit/s) optical transmission systems. The calculation methodology of non-refusal work and refusal probabilities, using the measured polarisation mode dispersion parameters, is proposed in the paper. Based on reliability calculations, the expected lifetime is then predicted, showing that all measured fibres most likely will be operational within minimum theoretical service life of 25 years accepted by the industry.

  15. Optical modeling of fiber organic photovoltaic structures using a transmission line method.

    Science.gov (United States)

    Moshonas, N; Stathopoulos, N A; O'Connor, B T; Bedeloglu, A Celik; Savaidis, S P; Vasiliadis, S

    2017-12-01

    An optical model has been developed and evaluated for the calculation of the external quantum efficiency of cylindrical fiber photovoltaic structures. The model is based on the transmission line theory and has been applied on single and bulk heterojunction fiber-photovoltaic cells. Using this model, optimum design characteristics have been proposed for both configurations, and comparison with experimental results has been assessed.

  16. An ME-PC Enhanced HDMR Method for Efficient Statistical Analysis of Multiconductor Transmission Line Networks

    KAUST Repository

    Yucel, Abdulkadir C.; Bagci, Hakan; Michielssen, Eric

    2015-01-01

    An efficient method for statistically characterizing multiconductor transmission line (MTL) networks subject to a large number of manufacturing uncertainties is presented. The proposed method achieves its efficiency by leveraging a high

  17. Evidence of localized wave transmission

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    LLNL [Lawrence Livermore National Lab.] experiments to test the feasibility of launching an acoustic, directed-energy pulse train (ADEPT) in water have demonstrated localized transmission of wave energy far beyond the classical Rayleigh length that defines the boundary between near-field and far-field transmission for Gaussian (diffraction-limited) pulses. The results of the experiments are in excellent agreement with computer simulations

  18. On-line analysis of bulk materials using pulsed neutron interrogation

    International Nuclear Information System (INIS)

    Lebrun, P.; Tourneur, P. Le; Poumarede, B.; Bach, P.; Moeller, H.

    1999-01-01

    On the basis of our joint experience in neutronics for SODERN and in cement plant engineering for KRUPP POLYSIUS, we have developed a new on-line bulk materials analyser for the cement industry. This equipment includes a pulsed neutron generator GENIE 16, some gamma ray and neutron detectors, specially designed electronics with high counting rate, software delivering the mean elemental composition of raw material, and adequate shielding. This material is transported through the equipment on a conveyor belt, the size of which is adapted to the requirements. This paper briefly describes the equipment and some results, as obtained in dynamic test from a demonstrator installed in Germany

  19. On-line analysis of bulk materials using pulsed neutron interrogation

    Science.gov (United States)

    Lebrun, P.; Tourneur, P. Le; Poumarede, B.; Möller, H.; Bach, P.

    1999-06-01

    On the basis of our joint experience in neutronics for SODERN and in cement plant engineering for KRUPP POLYSIUS, we have developed a new on-line bulk materials analyser for the cement industry. This equipment includes a pulsed neutron generator GENIE 16, some gamma ray and neutron detectors, specially designed electronics with high counting rate, software delivering the mean elemental composition of raw material, and adequate shielding. This material is transported through the equipment on a conveyor belt, the size of which is adapted to the requirements. This paper briefly describes the equipment and some results, as obtained in dynamic test from a demonstrator installed in Germany.

  20. Measuring the complex permittivity tensor of uniaxial biological materials with coplanar waveguide transmission line

    Science.gov (United States)

    A simple and accurate technique is described for measuring the uniaxial permittivity tensor of biological materials with a coplanar waveguide transmission-line configuration. Permittivity tensor results are presented for several chicken and beef fresh meat samples at 2.45 GHz....

  1. Analyzing the Health Risks Resulting from Extending the 400kV High Voltage Transmission Lines on the Human

    Directory of Open Access Journals (Sweden)

    Mohammed Hassan Dervish

    2018-01-01

    Full Text Available Although it is difficult to imagine life without electricity, there are compiling confirmations show thatexposure to magnetic fields correlated electricity and radio frequencies pose magnificent hazards to human health. The most economist method to transfer electricity from power generation stations to users is by measures of high power transmission lines, buoyed by big transmission towers. The cables laced between the towers radiate magnetic and electric fields. In this research study, the magnetic field at ground level under 400 kV network lines extended in residential places have been conducted in two ways, mathematical calculation and practical measurement then the obtained results analyzed and compared with the international standards reference values. the reason of chose this type of transmission line is frequently using. The results indicate that they fall within the safe limiter commended by the WorldHealth Organization. the strength of radiation increasing with high of sea level and moisture ratiobecause of air ionization.

  2. A Design of a PET Detector Using Micro-Channel Plate Photomultipliers with Transmission-Line Readout.

    Science.gov (United States)

    Kim, H; Frisch, H; Chen, C-T; Genat, J-F; Tang, F; Moses, W W; Choong, W S; Kao, C-M

    2010-01-01

    A computer simulation study has been conducted to investigate the feasibility of a positron emission tomography (PET) detector design by using micro-channel plate (MCP) photomultiplier tubes (PMT) with transmission-line (TL) read-out and waveform sampling. The detector unit consisted of a 24×24 array of pixelated LSO crystals, each of which was 4×4×25 mm(3) in size, and two 102×102 mm(2) MCP-PMTs coupled to both sides of the scintillator array. The crystal (and TL) pitch was 4.25 mm and reflective medium was inserted between the crystals. The transport of the optical photons inside the scintillator were simulated by using the Geant4 package. The output pulses of the MCP-PMT/TL unit were formed by applying the measured single photo-electron response of the MCP-PMT/TL unit to each individual photon that interacts with the photo-cathode of the MCP-PMT. The waveforms of the pulses at both ends of the TL strips were measured and analyzed to produce energy and timing information for the detected event. An experimental setup was developed by employing a Photonis Planacon MCP-PMT (XP85022) and a prototype TL board for measuring the single photo-electron response of the MCP-PMT/TL. The simulation was validated by comparing the predicted output pulses to measurements obtained with a single MCP-PMT/TL coupled to an LSO crystal exposed to 511 keV gamma rays. The validated simulation was then used to investigate the performance of the proposed new detector design. Our simulation result indicates an energy resolution of ~11% at 511 keV. When using a 400-600 keV energy window, we obtain a coincidence timing resolution of ~323 ps FWHM and a coincidence detection efficiency of ~40% for normally-incident 511keV photons. For the positioning accuracy, it is determined by the pitch of the TLs (and crystals) in the direction normal to the TLs and measured to be ~2.5 mm in the direction parallel to the TLs. The energy and timing obtained at the front- and back-end of the scintillator

  3. Method of selecting optimum cross arm lengths for a 750 kV transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Aleksandrov, G N; Olorokov, V P

    1965-01-01

    A method is presented, based on both technical and economic considerations, for selecting cross arm lengths for intermediate poles of power transmission lines according to the effects of internal overvoltage, methods from probability theory and mathematical statistics employed. The problem of optimum pole size is considered in terms of the effect of internal overvoltages for a prescribed maximum level of 2.1 PU currently used in the USSR for the design of 750 kV lines.

  4. Thermal Rectification in Graded Nonlinear Transmission Lines

    International Nuclear Information System (INIS)

    Xu Wen; Chen Wei-Zhong; Tao Feng

    2011-01-01

    We consider heat conduction in a nonlinear inductance-capacitance (LC) transmission line with an inductance gradient by adding white-noise signals. It is found that the heat flux in the direction of inductance decrease is larger than that in the direction of inductance increase. When the low-inductance end is at higher temperature, the phonon density decreases due to conversion to high-frequency phonons, which can not move to the high-inductance end due to its lower cutoff frequency. However, when the high-inductance end is at higher temperature, the loss of phonon density can be compensated for because some high-frequency phonons can move to the low-inductance end dur to its higher cutoff frequency. This leads to the asymmetry of energy transfer. Discussion shows that this asymmetry exists in a particular range of temperatures, and increases with the increase of the difference between heat baths and the inductance gradient. (fundamental areas of phenomenology(including applications))

  5. Long term investigation of thermal behaviour of 110 kV underground transmission lines in the Belgrade area

    Energy Technology Data Exchange (ETDEWEB)

    Sredojevic, M.R.; Naumov, R.M.; Popovic, D.P. [Nikola Tesla Electrical Engineering Inst., Belgrade (Yugoslavia); Simic, M.D. [Electrical Utility Co., Belgrade (Yugoslavia)

    1997-12-31

    The paper describes the procedure for applying a special cable backfill material, developed and manufactured at the Institute ``Nikola Tesla`` for the thermal stabilisation and reduction of hot spot cable operating temperature, on specific hot spots of 110 kV underground transmission lines in the Belgrade area. The results presented in this paper are an important contribution to the proof of the justification and necessity of defining and introducing in practice new procedures for the thermal stabilisation and reduction of operating temperature of existing, as well as of new, underground transmission cable lines to be built. (author)

  6. Simulation calculation for the energy deposition profile and the transmission fraction of intense pulsed electron beam at various incident angles

    International Nuclear Information System (INIS)

    Yang Hailiang; Qiu Aici; Zhang Jiasheng; Huang Jianjun; Sun Jianfeng

    2002-01-01

    The incident angles have a heavy effect on the intense pulsed electron beam energy deposition profile, energy deposition fraction and beam current transmission fraction in material. The author presents electron beam energy deposition profile and energy deposition fraction versus electron energy (0.5-2.0 MeV), at various incident angles for three aluminum targets of various thickness via theoretical calculation. The intense pulsed electron beam current transmission fractions versus electron energy (0.4-1.4 MeV) at various incident angles for three thickness of carbon targets were also theoretically calculated. The calculation results indicate that the deposition energy in unit mass of material surface layer increase with the rise of electron beam incident angle, and electron beam with low incident angle (closer to normal incident angle) penetrates deeper into the target material. The electron beams deposit more energy in unit mass of material surface layer at 60 degree-70 degree incident angle

  7. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  8. A NON-ISOTHERMAL THEORY FOR INTERPRETING SODIUM LINES IN TRANSMISSION SPECTRA OF EXOPLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Heng, Kevin; Lavie, Baptiste [University of Bern, Physics Institute, Center for Space and Habitability, Sidlerstrasse 5, CH-3012 Bern (Switzerland); Wyttenbach, Aurélien; Ehrenreich, David; Lovis, Christophe [Observatoire de l’Université de Genève, 51 chemin des Maillettes, CH-1290 Sauverny (Switzerland); Sing, David K., E-mail: kevin.heng@csh.unibe.ch [Astrophysics Group, School of Physics, University of Exeter, Stocker Road, Exeter EX4 4QL (United Kingdom)

    2015-04-10

    We present a theory for interpreting the sodium lines detected in transmission spectra of exoplanetary atmospheres. Previous analyses employed the isothermal approximation and dealt only with the transit radius. By recognizing the absorption depth and the transit radius as being independent observables, we develop a theory for jointly interpreting both quantities, which allows us to infer the temperatures and number densities associated with the sodium lines. We are able to treat a non-isothermal situation with a constant temperature gradient. Our novel diagnostics take the form of simple-to-use algebraic formulae and require measurements of the transit radii (and their corresponding absorption depths) at line center and in the line wing for both sodium lines. We apply our diagnostics to the HARPS data of HD 189733b, confirm the upper atmospheric heating reported by Huitson et al., derive a temperature gradient of 0.4376 ± 0.0154 K km{sup −1}, and find densities ∼1–10{sup 4} cm{sup −3}.

  9. Transmission Lines or Poles, Electric, Electric transmission lines locations provided to us from Kansas City Power and Light and City of Gardner only at this time. AIMS is working on getting other providers in area. Data is limited to CUE (Collaborative Utility Exchange) Participants and subc, Published in 2004, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Transmission Lines or Poles, Electric dataset current as of 2004. Electric transmission lines locations provided to us from Kansas City Power and Light and City of...

  10. Advanced Design of the First Quasi-optical Transmission Line for ECRH at TJ-II

    International Nuclear Information System (INIS)

    Fernandez, A.; Likin, K.; Martin, R.

    1999-01-01

    TJ-II plasma start-up and heating are made by electron cyclotron resonance waves at the second harmonic of the electron cyclotron frequency. The microwave power of the gyrotrons is transmitted by two quasi-optical transmission lines. The first line launches the microwave power under fixed injection geometry, i. e. there is no a possibility to change the launching angle the wave polarization. Due to the long distance between the last focusing mirror and the center TJ-II vessel the beam is quite wide at plasma border. The second line has a moveable mirror installed inside the TJ-II vessel. To get high absorption efficiency and a narrow energy deposition profile the internal mirror focuses the wave beam at plasma center. The beam width is about 2 cm. To get more flexibility in experiments on heating and current drive the first transmission line needs to be upgraded. The designs is presented in this report. It includes and internal mirror to focus the beam and to change the injection angle. A polarizer consisting in two corrugated mirrors will be incorporated to get any wave polarization. Two mirrors with an array of coupling holes and calorimetric measurements of the energy absorbed in the barrier window will permit the estimation of the microwave power launched the TJ-II. (Author) 13 refs

  11. A transmission line model for propagation in elliptical core optical fibers

    Science.gov (United States)

    Georgantzos, E.; Papageorgiou, C.; Boucouvalas, A. C.

    2015-12-01

    The calculation of mode propagation constants of elliptical core fibers has been the purpose of extended research leading to many notable methods, with the classic step index solution based on Mathieu functions. This paper seeks to derive a new innovative method for the determination of mode propagation constants in single mode fibers with elliptic core by modeling the elliptical fiber as a series of connected coupled transmission line elements. We develop a matrix formulation of the transmission line and the resonance of the circuits is used to calculate the mode propagation constants. The technique, used with success in the case of cylindrical fibers, is now being extended for the case of fibers with elliptical cross section. The advantage of this approach is that it is very well suited to be able to calculate the mode dispersion of arbitrary refractive index profile elliptical waveguides. The analysis begins with the deployment Maxwell's equations adjusted for elliptical coordinates. Further algebraic analysis leads to a set of equations where we are faced with the appearance of harmonics. Taking into consideration predefined fixed number of harmonics simplifies the problem and enables the use of the resonant circuits approach. According to each case, programs have been created in Matlab, providing with a series of results (mode propagation constants) that are further compared with corresponding results from the ready known Mathieu functions method.

  12. A transmission line model for propagation in elliptical core optical fibers

    International Nuclear Information System (INIS)

    Georgantzos, E.; Boucouvalas, A. C.; Papageorgiou, C.

    2015-01-01

    The calculation of mode propagation constants of elliptical core fibers has been the purpose of extended research leading to many notable methods, with the classic step index solution based on Mathieu functions. This paper seeks to derive a new innovative method for the determination of mode propagation constants in single mode fibers with elliptic core by modeling the elliptical fiber as a series of connected coupled transmission line elements. We develop a matrix formulation of the transmission line and the resonance of the circuits is used to calculate the mode propagation constants. The technique, used with success in the case of cylindrical fibers, is now being extended for the case of fibers with elliptical cross section. The advantage of this approach is that it is very well suited to be able to calculate the mode dispersion of arbitrary refractive index profile elliptical waveguides. The analysis begins with the deployment Maxwell’s equations adjusted for elliptical coordinates. Further algebraic analysis leads to a set of equations where we are faced with the appearance of harmonics. Taking into consideration predefined fixed number of harmonics simplifies the problem and enables the use of the resonant circuits approach. According to each case, programs have been created in Matlab, providing with a series of results (mode propagation constants) that are further compared with corresponding results from the ready known Mathieu functions method

  13. Development of a compact generator for gigawatt, nanosecond high-voltage pulses

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Lin, E-mail: zhoulin-2003@163.com; Jiang, Zhanxing; Liang, Chuan; Li, Mingjia; Wang, Wenchuan; Li, Zhenghong [Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, P.O. Box 919-226, Mianyang 621999 (China)

    2016-03-15

    A compact generator producing 2.2-ns 1.5 GW high-voltage pulses was developed. The generator employed a 27.6 Ω, 0.9 ns pulse-forming-line (PFL), which was charged by an iron core transformer with a turn ratio of 2:33.5 and a coefficient of 0.94. A 1.2 μF, 20 kV capacitor and a hydrogen thyratron were used in the primary circuit. When the thyratron closed at 14.5 kV, 3.4% of the energy stored in the capacitor was delivered to the PFL in 850 ns, producing a peak voltage of up to ∼500 kV. In addition, the principle of triple resonance transformation was employed by adding a 50 pF tuning capacitor and a 1.15 mH inductor between the transformer and the PFL, which led to a significant reduction of the duration and peak value of the transformer voltage without reducing that in the PFL. Meanwhile, an adjustable self-break oil switch was applied. By using transmission lines with impedance overmatched to that of the PFL, the generator delivered a 512 kV pulse across an electron beam diode, generating radiation with a dose of 20 mR/pulse at 20 cm ahead of the diode. The generator provides an excellent ultra-short radiation pulse source for the studies on radiation physics.

  14. Coupling of an applied field magnetically insulated ion diode to a high power magnetically insulated transmission line system

    International Nuclear Information System (INIS)

    Maenchen, J.E.

    1983-01-01

    The coupling of energy from a high power pulsed accelerator through a long triplate magnetically insulated transmission line (MITL) in vacuum to an annular applied magnetic field insulated extraction ion diode is examined. The narrow power transport window and the wave front erosion of the MITL set stringent impedance history conditions on the diode load. A new ion diode design developed to satisfy these criteria with marginal electron insulation is presented. The LION accelerator is used to provide a positive polarity 1.5 MV, 350 kA, 40 ns FWHM pulse with a 30 kA/ns current rate from a triplate MITL source. A transition converts the triplate into a cylindrical cross section which flares into the ion diode load. Extensive current and voltage measurements performed along this structure and on the extracted ion beam provide conclusive evidence that the self insulation condition of the MITL is maintained in the transition by current loss alone. The ion diode utilizes a radial magnetic field between a grounded cathode annular emission tip and a disk anode. A 50 cm 2 dielectric/metal anode area serves as the ion plasma source subject to direct electron bombardment from the opposing cathode tip under marginal magnetic insulation conditions. The ions extracted cross the radial magnetic field and exit the diode volume as an annular cross section beam of peak current about 100 kA. The diode current gradually converts from the initial electron flow to nearly 100% ion current after 30 ns, coupling 60% of the diode energy into ions

  15. A compact very wideband amplifying filter based on RTD loaded composite right/left-handed transmission lines.

    Science.gov (United States)

    Abu-Marasa, Mahmoud O Mahmoud; El-Khozondar, Hala Jarallah

    2015-01-01

    The composite right/left-handed (CRLH) transmission line (TL) is presented as a general TL possessing both left-handed (LH) and right-handed (RH) natures. RH materials have both positive permittivity and positive permeability, and LH materials have both negative permittivity and negative permeability. This paper aims to design and analyze nonlinear CRLH-TL transmission line loaded with resonant tunneling diode (RTD). The main application of this design is a very wideband and compact filter that amplifies the travelling signal. We used OrCAD and ADS software to analyze the proposed circuit. CRLH-TL consists of a microstrip line which is loaded with complementary split-rings resonators (CSRRs), series gaps, and shunt inductor connected parallel to the RTD. The designed structure possess a wide band that ranges from 5 to 10.5 GHz and amplifies signal up to 50 %. The proposed design is of interest to microwave compact component designers.

  16. Commissioning of the 28 GHz ECRH power transmission line for the TJ-II stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Fernández, J., E-mail: jose.martinez@ciemat.es [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Cappa, Á. [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Chirkov, A. [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod (Russian Federation); Ros, A.; Tolkachev, A.; Catalán, G.; Soleto, A.; Redondo, M. [Laboratorio Nacional de Fusión (LNF), Centro de Investigaciones Tecnológicas, Medioambientales y Tecnológicas (CIEMAT), Av/Complutense 40, 28040 Madrid (Spain); Doane, J.L.; Anderson, J.P. [General Atomics, P.O. Box 85608, San Diego, CA 92186-5608 (United States)

    2015-10-15

    Highlights: • The 28 GHz power transmission line of the TJ-II stellarator is described. • Mismatch and alignment problems are covered, presenting infrared measurements. • Beam distortion in the matching optics unit led to unwanted modes in the waveguide. • After a redesign distortion was eliminated and coupling maximized. • Final measurements suggest finer alignment must be performed. - Abstract: The commissioning of the 28 GHz power transmission line of the TJ-II stellarator, designed for the excitation of electron Bernstein waves (EBW) through the O-X-B mode conversion process, is presented in this paper. Based upon a comprehensive set of thermal measurements, its purpose is to go into details about the several problems that arouse during the whole process, namely higher order modes excitation because of the wider beam size and alignment mismatches at the waveguide mouth. All these drawbacks may have prevented the correct O-X mode conversion, thus providing a reasonable explanation for the unsuccessful EBW heating experiments.

  17. Distance protection of multiple-circuit shared tower transmission lines with different voltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    combined faults, being advised to increase the resistive limit of the protection zone, if the network has lower short-circuit power. It is recommended to assure that the fault can only happen for cases where the faulted phase from the higher voltage level leads the faulted phase from the lower voltage......Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. In this study, the fault loop impedance of combined faults is compared with the fault loop impedance......-phase-to-ground faults. It is also demonstrated that the fault loop impedance of combined faults is more resistive, when compared with equivalent single-phase-to-ground faults. It is concluded that the settings used to protect a line against single-phase-to-ground faults are capable of protecting the line against...

  18. In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Mueller Steffen; Wibbing Sascha; Weigel Robert; Koelpin Alexander; Dennerlein, Juergen; Janke, Iryna; Weber, Johannes

    2015-01-01

    Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails

  19. In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Mueller Steffen; Wibbing Sascha; Weigel Robert; Koelpin Alexander [Institute for Electronics Engineering, University of Erlangen-Nuremberg (Germany); Dennerlein, Juergen; Janke, Iryna; Weber, Johannes [AREVA GmbH, Paul-Gossen-Str. 100, 91052 Erlangen (Germany)

    2015-07-01

    Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails

  20. Progress of high power and long pulse ECRH system in EAST

    International Nuclear Information System (INIS)

    Wang, Xiaojie; Liu, Fukun; Shan, Jiafang; Xu, Handong; DajunWu; Li, Bo; Wei, Wei; Zhang, Jian; Huang, Yiyun; Tang, Yunying; Xu, Weiye; Hu, Huaichuan; Wang, Jian; Xu, Li; Zhang, Liyuan; Feng, Jianqiang

    2015-01-01

    Highlights: • The design and the status of the 140 GHz/4 MW/1000 s ECRH system on EAST tokamak is described in detail. • Two of the four gyrotrons are tested in factory. • The transmission line and the equatorial launcher for the first 2 MW system are ready for installation. • Series tests have been carried out for the most critical elements for the real-time launcher. • The auxiliary system includes the water cooling system, the HVPS system, the vacuum system have been installed and tested. - Abstract: In accordance with the long pulse objectives of the Experimental Advanced Superconducting Tokamak (EAST), an electron cyclotron resonance heating (ECRH) system with the feature of 4 MW power for a pulse length up to 1000 s at 140 GHz, using second harmonic of the extraordinary mode (X2) is presently under construction at the institute of plasma physics, Chinese academy of sciences (ASIPP). The missions of the system are to provide central heating, current drive, plasma profile tailoring and control of magneto-hydrodynamic (MHD) instabilities. The continuous wave (CW) power is transmitted from the gyrotrons to EAST via low-loss evacuated waveguide transmission lines. Considering the diverse applications of the EC system, the front steering launcher is designed to inject four individually steered beams across nearly the entire plasma cross section. The beam's launch angles can be continuously varied with the optimized scanning range of over 30° in poloidal direction and ±25° in toroidal, as well as the polarization will be adjusted during the discharge by the orientations of a pair of polarizers in the transmission line to maintain the highest absorption for different operational scenarios. The commissioning of the first 2 MW system will be commenced in the end of 2014.

  1. Updating the induction module from single-pulse to double-pulses

    International Nuclear Information System (INIS)

    Huang Ziping; Wang Huacen; Deng Jianjun

    2002-01-01

    A double-pulse Linear Induced Accelerator (LIA) module is reconstructed based on a usual simple-pulse LIA module. By changing the length of one of the cables between the inductive cell and the Blumlein pulse forming line, two induction pulses with 90 ns FWHM and 150 kV pulse voltage are generated by the ferrite cores inductive cell. The interval time of the pulses is adjustable by changing the lengths of the cable

  2. Optimization of the vacuum insulator stack of the MIG pulsed power generator

    International Nuclear Information System (INIS)

    Khamzakhan, G; Chaikovsky, S A

    2014-01-01

    The MIG multi-purpose pulsed power machine is intended to generate voltage pulses of amplitude up to 6 MV with electron-beam loads and current pulses of amplitude up to 2.5 MA and rise time '00 ns with inductive loads like Z pinches. The MIG generator is capable of producing a peak power of 2.5 TW. Its water transmission line is separated from the vacuum line by an insulator stack. In the existing design of the insulator, some malfunctions have been detected. The most serious problems revealed are the vacuum surface flashover occurring before the current peaks and the deep discharge traces on the water-polyethylene interface of the two rings placed closer to the ground. A comprehensive numerical simulation of the electric field distribution in the insulator of the MIG generator has been performed. It has been found that the chief drawbacks are nonuniform voltage grading across the insulator rings and significant enhancement of the electric field at anode triple junctions. An improved design of the insulator stack has been developed. It is expected that the proposed modification that requires no rearrangement of either the water line or the load-containing vacuum chamber will provide higher electric strength of the insulator

  3. Parametric amplifications in the nonlinear transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Kawata, T; Sakai, J; Inoue, H [Toyama Univ., Takaoka (Japan). Faculty of Engineering

    1980-03-01

    The parametric amplification in a transmission line with nonlinear capacitors is analysed theoretically using the equations of three wave interactions. Since this line has two modes, high frequency and low frequency modes, there may occur some mode coupling phenomena through the resonant interactions. We consider three waves with wave number k sub(j) and frequency ..omega..sub(j) in resonance with each other, that is, ..omega../sub 1/ + ..omega../sub 2/ = ..omega../sub 3/ and k/sub 1/ + k/sub 2/ = k/sub 3/, where 0 <= ..omega../sub 1/ <= ..omega../sub 2/ <= ..omega../sub 3/ and k/sub 3/ >= 0. Such conditions are realized in our network and there exist two states: ''forward state'' (each group velocity is positive) and ''backward state'' (one of the group velocities is negative). The coupled equations of three waves has two constant pumps: high frequency (HF) pump and low frequency (LF) pump. Using linear approximations, we examine the possible types of parametric amplification and obtain the power gains depending on the frequency deviation. For only the case of HF pump we get the gain between signals with seme frequency and also get the gain from the low frequency signal to the high frequency signal (''up-conversion'') for the LF pump. The nonlinear analysis gives the exact relation between input and output signals. For the forward state the gain is absolutely suppressed by the ratio of pumping power to input power, while the gain of backward state has no finite maximum and there may appear an ''oscillating state'' if the pumping power is comparatively small.

  4. Artificial neural networks to estimate the EMF ELF on car travelling near power transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Al-Sayegh, O.A.; Qabazard, A.M. [Kuwait Inst. for Scientific Research, Safat (Kuwait). advanced Systems Division of Environment and Urban

    2007-07-01

    An artificial neural network (ANN) was developed to determine the electromagnetic field (EMF) and extremely low frequency (ELF) intensity on a vehicle body at different distances from a high tension power line and at varying power loads. EMF radiated emissions from ELF source power transmission lines can produce interference in the electric components in vehicles traveling at variable speed near the power lines. The passengers in the vehicle may also experience EMF-related health problems. Although EMF has been recently categorized as a new form of pollution, the situation has been largely ignored by the industry. Typically, electromagnetic fields at different frequencies show the fastest growing environmental influences. All populations are now exposed to varying degrees of EMF and the levels will continue to increase as technology advances. The purpose of this work was to promote discussion and help find design solutions to manufacture a new device for measuring the EMF at variable speed. In this study, a set of near field measurements outside the vehicle were used to train ANN. Estimations of the EMF ELF for various distances from the high tension power line were presented. It was determined that the most important factors affecting the electric field model include exposure conditions; size, shape and position of the exposed body in the field; and, surface charge density. The EMF ELF was found to increase near sagging areas of the overhead power transmission line. The EMF ELF was found to be proportional to the total amps flowing through the line at the time of measurement. 14 refs., 3 figs.

  5. Common raven occurrence in relation to energy transmission line corridors transiting human-altered sagebrush steppe

    Science.gov (United States)

    Coates, Peter S.; Howe, Kristy B.; Casazza, Michael L.; Delehanty, David J.

    2014-01-01

    Energy-related infrastructure and other human enterprises within sagebrush steppe of the American West often results in changes that promote common raven (Corvus corax; hereafter, raven) populations. Ravens, a generalist predator capable of behavioral innovation, present a threat to many species of conservation concern. We evaluate the effects of detailed features of an altered landscape on the probability of raven occurrence using extensive raven survey (n= 1045) and mapping data from southern Idaho, USA. We found nonlinear relationships between raven occurrence and distances to transmission lines, roads, and facilities. Most importantly, raven occurrence was greater with presence of transmission lines up to 2.2 km from the corridor.We further explain variation in raven occurrence along anthropogenic features based on the amount of non-native vegetation and cover type edge, such that ravens select fragmented sagebrush stands with patchy, exotic vegetative introgression. Raven occurrence also increased with greater length of edge formed by the contact of big sagebrush (Artemisia tridentate spp.) with non-native vegetation cover types. In consideration of increasing alteration of sagebrush steppe, these findings will be useful for planning energy transmission corridor placement and other management activities where conservation of sagebrush obligate species is a priority.

  6. Laser ablation comparison by picosecond pulses train and nanosecond pulse

    Science.gov (United States)

    Lednev, V. N.; Filippov, M. N.; Bunkin, A. F.; Pershin, S. M.

    2015-12-01

    A comparison of laser ablation by a train of picosecond pulses and nanosecond pulses revealed a difference in laser craters, ablation thresholds, plasma sizes and spectral line intensities. Laser ablation with a train of picosecond pulses resulted in improved crater quality while ablated mass decreased up to 30%. A reduction in laser plasma dimensions for picosecond train ablation was observed while the intensity of atomic/ionic lines in the plasma spectra was greater by a factor of 2-4 indicating an improved excitation and atomization in the plasma.

  7. Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages

    Directory of Open Access Journals (Sweden)

    ISTRATE, M.

    2009-10-01

    Full Text Available The increased accuracy into the fault's detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids' lines are presented. The double-end synchronized data algorithms are very precise, but the current transformers can limit the accuracy of these estimations. The paper presents an algorithm to estimate the location of the single-phased faults which uses only voltage measurements at both terminals of the transmission lines by eliminating the error due to current transformers and without introducing the restriction of perfect data synchronization. In such conditions, the algorithm can be used with the actual equipment of the most power grids, the installation of phasor measurement units with GPS system synchronized timer not being compulsory. Only the positive sequence of line parameters and sources are used, thus, eliminating the incertitude in zero sequence parameter estimation. The algorithm is tested using the results of EMTP-ATP simulations, after the validation of the ATP models on the basis of registered results in a real power grid.

  8. Contribution to the study of an on line inspection system for pulsed Nd:YAG laser welding operations

    International Nuclear Information System (INIS)

    Charton, Stephane

    1999-01-01

    This thesis deals with the study of a on line inspection system for pulsed Nd 3+ :YAG laser welding operations. During a welding operation, laser-material interaction results in the emission of signals (optical, acoustical, electrical, thermal), characteristic of its behavior. On line inspection is based on the hypothesis that the signals evolutions, measured by sensors such as photodiodes, microphones.., may be correlated with the welding defects. Laser weld quality inspection can be done by the machine qualification (before and during welding), and by on line monitoring of the welding operation. The similarity of the signals produced by pulsed lasers (machine or interaction) has led us to develop a specific data acquisition and processing software. Signal processing tools utilization (Fourier and wavelets transforms) in conjunction with classification techniques (stress polytopes), introduces an innovating on line inspection approach. Discriminant parameters determination (signals/defect correlation) becomes thus automatic and non subjective. The developed prototype is not dedicated to the detection of a particular defect because the classification operator is a supervised one and needs a learning phase. lt has been validated on welding defects which are easy to deal with, and then applied to a precise production control at the Nuclear Fabrications and Technology Division of the Valduc Center of the French Atomic Energy Agency. (author) [fr

  9. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-KV Transmission Line

    Science.gov (United States)

    Lee, Jack Monroe, Jr.

    There is ongoing controversy about the possibility of adverse biological effects from environmental exposures to electric and magnetic fields. These fields are produced by all electrical equipment and appliances including electrical transmission lines. The objective of this environmental science study was to investigate the possible effects of a high voltage transmission line on domestic sheep (Ovis aries L.), a species that can often be found near such lines. The study was primarily designed to determine whether a specific effect of electric and magnetic fields found in laboratory animals also occurs in livestock under natural environmental conditions. The effect is the ability of fields, at levels found in the environment, to significantly depress the normally high nocturnal concentrations of the pineal hormone-melatonin. Ten female Suffolk lambs were penned for 10 months directly beneath a 500-kV transmission line near Estacada, Oregon. Ten other lambs of the same type were penned in a control area away from the transmission line where electric and magnetic fields were at ambient levels. Serum melatonin was analyzed by radioimmunoassay (RIA) from 6618 blood samples collected at 0.5 to 3-hour intervals over eight 48-hour periods. Serum progesterone was analyzed by RIA from blood samples collected twice weekly. Serum cortisol was also assayed by RIA from the blood samples collected during the 48-hour samples. Results showed that lambs in both the control and line groups had the typical pattern of melatonin secretion consisting of low daytime and high nighttime serum concentrations. There were no statistically significant differences between groups in melatonin levels, or in the phase or duration of the nighttime melatonin elevation. Age at puberty and number of reproductive cycles also did not differ between groups. Serum cortisol showed a circadian rhythm with highest concentrations during the day. There were, however, no differences in cortisol concentrations

  10. Visual impact of overhead power transmission lines and dielectric and corona effects constraints on insulation coordination

    International Nuclear Information System (INIS)

    Deponti, F.; Fini, G.P.; Porrino, A.; Rosa, F.

    1992-06-01

    In assessing overhead power transmission line design and planning criteria for the optimization of visual impact, safety and the reduction of electro magnetic disturbance effects, this paper reviews the research findings of ENEL, the Italian Electricity Board. The on-going research activities involve theoretical calculations and laboratory performance tests to determine the best compact configurations for 380 kV lines. The parameters under examination include: insulator spacing, sizing and salt fog resistivity; allowable overvoltages; maximum line length; behaviour in lightning conditions; radio and acoustics disturbances

  11. Full Scale Experimental Study on the Air Insulation of 765kV Transmission Lines

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Boo; Shin, Jeong Woon; Cho, Sung Bae; Chang, Sung Chil; Kwak, Joo Shik [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Kim, Ik Soo; Lee, Heyoung Ho; Kang, Young Sik; Lee, Hong Sik; Choi, Beyoung Joo; Kim, Young Bae [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of)

    1997-12-31

    Design and construction of testing yard. Technical specification of impulse voltage generator which was installed in testing yard. Corrosion and statistical analysis of test data. Test object setup and test results of flashover characteristic in various paths. Recommended optimum air clearance of 765kV transmission lines. (author). 163 refs., figs.

  12. Transmission line properties of long strings of superconducting magnets

    International Nuclear Information System (INIS)

    Shafer, R.E.

    1980-09-01

    The purpose of this paper is to discuss the electrical characteristics of a long string of superconducting magnets, such as in a superconducting storage ring or accelerator. As the magnets have a shunt capacitance to ground as well as a series inductance, travelling waves can propagate along the string, as in a transmission line. As the string is of finite length, standing waves can also exist. In accelerator quality superconducting magnets, considerable effort has been devoted to minimizing ac losses, the net result being that the magnet string has a high Q precisely at the frequencies which are important for the standing and travelling waves. The magnitude of these effects are estimated, and the solution to be used at Fermilab will be discussed

  13. Recovery and updating of power transmission lines. The experience made by ELETROSUL; Recapacitacao e repotenciacao de linhas de transmissao. A experiencia da ELETROSUL

    Energy Technology Data Exchange (ETDEWEB)

    Stephan, Jose Carlos de Saboia [ELETROSUL, Curitiba, PR (Brazil)]. E-mail: jcsaboia@eletrosul.gov.br

    2001-07-01

    This document presents a procedures synthesis for analysis and verification of power transmission line adjustments, aiming their recovery or power updating, it also shows the executed procedures during the stages of preliminary design, final design and construction of the modernized transmission lines by ELETROSUL for the 138, 230 and 500 Kv tensions. The concepts on which the evaluation criteria of the structural components for the transmission lines(metallic supports, foundations in metallic grills and reinforced concrete) have been based are presented, as well as the main aspects of the used methodologies for that. It also makes a comparative analysis related to the used processes for structural analyses of the metallic support in trelliswork (computational process which uses the finite element and graphical methods), as well as the foundations of these supports (structural verifications and others). Also are reported the researches and jobs which involved the power updating of the three 138 and 230 kv transmission lines of ELETROSUL.

  14. Quantifying siting difficulty: a case study of US transmission line siting

    Energy Technology Data Exchange (ETDEWEB)

    Vajjhala, S.P. [Resources for the Future, Washington DC (United States); Fischbeck, P.S. [Carnegie Mellon University, Pittsburgh, PA (United States). Departments of Social and Decision Sciences and Engineering and Public Policy

    2007-01-15

    The worldwide demand for new energy infrastructures has been paralleled in recent years by the increasing difficulty of siting major facilities. Siting difficulty is the subject of widespread discussion, but because of the complexity of the problem, potential solutions are not obvious or well understood. This paper presents a two-step policy-level framework that first develops an empirical measure of siting difficulty and then qualitatively assesses its major causes. The approach is based on the creation and aggregation of four siting indicators that are independent of the common causes and localized effects of siting problems. The proposed framework is demonstrated for the case of US transmission line siting. Results of the analyses reveal significant variations in state siting difficulty and industry experts' perceptions of its dominant causes, with implications for the long-term success of Regional Transmission Organizations (RTOs) and knowledge transfer among siting professionals in the deregulated industry. (author)

  15. Development of electric power transmission line anomaly approaching alarm system. Sodensen ijo sekkin keiho sochi no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kusaba, Masaro; Tabata, Takatoshi; Miyazaki, Shusuke [Kyushu Electric Power Co., Inc., Fukuoka (Japan)

    1989-03-30

    In order to plan preventive measures from the occurrence of electric power transmission line accident, a power transmission line anomaly approaching alarm system was developed to automatically alarm the operators and surveillants. The surveillance system, composed of camera, surveillance unit proper and alarm receiving portion, generates alarm and indicate hazard to the operators, when animal invades a hazardous area designated on the monitor. Wireless telegraph for the alarm transmission use used frequency around a 322MHz band with the Radio Ray law and preventive measures from noise, taken into consideration. The prototype is characterized by unnecessary ancillary fitting to the surveillance object, rare erroneous operations and high reliability. While the hazardous area can be simply designated, changed and released, as made by volume on the control panel. It is moreover easy to designate, as done by confirming the surveillance object on the display. It is also possible in multidimensional surveillance and easy to use on site. 7 figs.

  16. Simplified method to solve sound transmission through structures lined with elastic porous material.

    Science.gov (United States)

    Lee, J H; Kim, J

    2001-11-01

    An approximate analysis method is developed to calculate sound transmission through structures lined with porous material. Because the porous material has both the solid phase and fluid phase, three wave components exist in the material, which makes the related analysis very complicated. The main idea in developing the approximate method is very simple: modeling the porous material using only the strongest of the three waves, which in effect idealizes the material as an equivalent fluid. The analysis procedure has to be conducted in two steps. In the first step, sound transmission through a flat double panel with a porous liner of infinite extents, which has the same cross sectional construction as the actual structure, is solved based on the full theory and the strongest wave component is identified. In the second step sound transmission through the actual structure is solved modeling the porous material as an equivalent fluid while using the actual geometry of the structure. The development and validation of the method are discussed in detail. As an application example, the transmission loss through double walled cylindrical shells with a porous core is calculated utilizing the simplified method.

  17. Electric transmission technology

    International Nuclear Information System (INIS)

    Shah, K.R.

    1990-01-01

    Electric transmission technology has matured and can transmit bulk power more reliably and economically than the technology 10 years ago.In 1882, Marcel Depres transmitted 15 kW electric power at 2 kV, using a constant direct current; present transmission voltages have risen to ± 600 kV direct current (DC) and 765 kV alternating current (AC), and it is now possible to transmit bulk electric power at voltages as high as ± 1000 kV DC and 1500 kV AC. Affordable computer systems are now available to optimize transmission reliably. New materials have reduced the bulk of insulation for lines and equipment. New conducting materials and configurations have reduced losses in transmission. Advances in line structures and conductor motion, understanding of flashover characteristics of insulators and air-gaps and electrical performance of lines have resulted in more compact urban transmission lines. (author). 15 refs., 7 tabs., 11 figs

  18. Effects of dispersion on electromagnetic parameters of tape-helix Blumlein pulse forming line of accelerator

    International Nuclear Information System (INIS)

    Zhang, Y.; Liu, J.L.; Feng, J.H.

    2012-01-01

    In this paper, the tape-helix model is introduced in the field of intense electron beam accelerator to analyze the dispersion effects on the electromagnetic parameters of helical Blumlein pulse forming line (PFL). Work band and dispersion relation of the PFL are analyzed, and the normalized coefficients of spatial harmonics are calculated. Dispersion effects on the important electromagnetic parameters of PFL, such as phase velocity, slow-wave coefficient, electric length and pulse duration, are analyzed as the central topic. In the PFL, electromagnetic waves with different frequencies in the work band of PFL have almost the same phase velocity. When de-ionized water, transformer oil and air are used as the PFL filling dielectric, respectively, the pulse duration of the helical Blumlein PFL is calculated as 479.6 ns, 81.1 ns and 53.1 ns in order. Electromagnetic wave simulation and experiments are carried out to demonstrate the theoretical calculations of the electric length and pulse duration which directly describe the phase velocity and dispersion of the PFL. Simulation results prove the theoretical analysis and calculation on pulse duration. Experiment is carried out based on the tape-helix Blumlein PFL and magnetic switch system. Experimental results show that the pulse durations are tested as 460 ns, 79 ns and 49 ns in order when de-ionized water, transformer oil and air are used respectively. Experimental results basically demonstrate the theoretical calculations and the analyses of dispersion. (authors)

  19. Equivalent circuit modeling of space charge dominated magnetically insulated transmission lines

    Energy Technology Data Exchange (ETDEWEB)

    Hiraoka, Kazuki; Nakajima, Mitsuo; Horioka, Kazuhiko

    1997-12-31

    A new equivalent circuit model for space charge dominated MITLs (Magnetically Insulated Transmission Lines) was developed. MITLs under high power operation are dominated with space charge current flowing between anode and cathode. Conventional equivalent circuit model does not account for space charge effects on power flow. The model was modified to discuss the power transportation through the high power MITLs. With this model, it is possible to estimate the effects of space charge current on the power flow efficiency, without using complicated particle code simulations. (author). 3 figs., 3 refs.

  20. Four-deep charge-time and pulse-width scaling discriminator for delay line MWPC's

    International Nuclear Information System (INIS)

    Lee, K.L.; Kirsten, F.A.; Grigorian, A.; Guiragossian, Z.G.T.

    1976-01-01

    A discriminator has been developed for digitizing both intercepted total charge and location of electromagnetic shower and particle trajectories in multi-wire proportional chambers read by delay lines. Determination of shower trajectory is aided by video signal integration followed by centroid-locating discrimination. Calibrated run-down of the signal integrating capacitor gives the charge information above a given threshold level. The discriminator is designed to handle up to four shower-induced video signals per event by incorporating steering circuits within the module. Each video signal is examined for time over an adjustable threshold. Video pulses with separation of less than 20 nsec are treated as a single pulse. Counter-logic circuits indicate the number of video signals digitized. These signal processing circuits provide a first level of data sifting which otherwise must be carried out with additional discriminator channels and added complexity in data recognition

  1. EBFA: pulsed power for fusion

    International Nuclear Information System (INIS)

    Martin, T.H.; VanDevender, J.P.; Barr, G.W.; Johnson, D.L.

    1979-01-01

    This paper will describe the EBFA I accelerator under construction for inertial confinement fusion studies with particle beams and will update previous publications concerning particle beam fusion accelerators. Previous information included Proto I, a triggered oil insulated 1 TW accelerator; Proto II, a water insulated 10 TW accelerator; and EBFA I, a 30 TW, 1 MJ accelerator. Some modifications to the original design have occurred. A new pulse-forming-line concept has been developed which increases the flexibility of the accelerator. The major problem of vacuum interface flashover has been solved by the use of long, magnetically-insulated, transmission lines. The first production module of EBFA I has been received, assembled, and is now undergoing extensive testing. The technology is extendable to at least a factor of ten above the projected EBFA capabilities of 30 TW and 1 MJ output. Progress on facilities associated with the Sandia Particle Beam fusion program is reported

  2. An overview of the mechanical design of the Atlas pulsed power machine

    CERN Document Server

    Bowman, D W; Barr, G W; Bennett, G A; Cochrane, J C; Davis, H A; Davis, T O; Dorr, G; Gribble, R F; Griego, J R; Hood, M; Kimerly, H J; Martínez, A; McCuistian, B T; Miller, R B; Ney, S A; Nielsen, K; Pankuch, P; Parsons, W M; Potter, C; Ricketts, R L; Salazar, H R; Scudder, D W; Shapiro, C; Thompson, M C; Trainor, R J; Valdez, G A; Yonemoto, W; Kirbie, H C

    1999-01-01

    Atlas is a pulsed-power facility being designed at Los Alamos National Laboratory to perform high-energy density experiments in support of Science-Based Stockpile Stewardship and basic research programs. Atlas will consist of 24 individual maintenance units, each consisting of 4 240-kV Marx units. Maintenance units are contained in large oil tanks arrayed in a circle about a central target chamber. Total stored energy of the capacitor bank will be 23 MJ. Maintenance units will discharge through an output shorting switch into a vertical tri-plate transmission line, and from there into a transition area/collector inside a large vacuum chamber. An overview of mechanical design aspects of the Atlas machine is presented. These include maintenance unit design and design of the tri-plate transmission line and transition region. Findings from fabrication and testing of prototype systems are discussed. (2 refs).

  3. 100 Gb/s single VCSEL data transmission link

    DEFF Research Database (Denmark)

    Rodes Lopez, Roberto; Estaran Tolosa, Jose Manuel; Li, Bomin

    2012-01-01

    100 Gb/s optical fiber transmission link with a single 1.5 um VCSEL has been experimentally demonstrated using 4-level pulse amplitude modulation.......100 Gb/s optical fiber transmission link with a single 1.5 um VCSEL has been experimentally demonstrated using 4-level pulse amplitude modulation....

  4. Residual life assessment of overhead transmission lines 110 kV and above and determination of their reconstruction terms

    Directory of Open Access Journals (Sweden)

    Uteuliyev Bauyrzhan

    2017-01-01

    Full Text Available In this article is given a method for assessment the residual life of overhead transmission lines on reinforced concrete supports with centrifuged poles. Reinforced concrete poles of supports, wires and lightning protection cables are adopted as the main elements. The intensity of change in the actual state parameters of these elements is determined by the laws of random variables distribution that allow predicting the residual life and the timing of repairs and reconstruction of overhead transmission lines. The parameters of natural climatic conditions and other external factors are considered by including of coefficients into the formula for changing the actual state parameters.

  5. A hybrid Boundary Element Unstructured Transmission-line (BEUT) method for accurate 2D electromagnetic simulation

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, Daniel, E-mail: daniel.simmons@nottingham.ac.uk; Cools, Kristof; Sewell, Phillip

    2016-11-01

    Time domain electromagnetic simulation tools have the ability to model transient, wide-band applications, and non-linear problems. The Boundary Element Method (BEM) and the Transmission Line Modeling (TLM) method are both well established numerical techniques for simulating time-varying electromagnetic fields. The former surface based method can accurately describe outwardly radiating fields from piecewise uniform objects and efficiently deals with large domains filled with homogeneous media. The latter volume based method can describe inhomogeneous and non-linear media and has been proven to be unconditionally stable. Furthermore, the Unstructured TLM (UTLM) enables modelling of geometrically complex objects by using triangular meshes which removes staircasing and unnecessary extensions of the simulation domain. The hybridization of BEM and UTLM which is described in this paper is named the Boundary Element Unstructured Transmission-line (BEUT) method. It incorporates the advantages of both methods. The theory and derivation of the 2D BEUT method is described in this paper, along with any relevant implementation details. The method is corroborated by studying its correctness and efficiency compared to the traditional UTLM method when applied to complex problems such as the transmission through a system of Luneburg lenses and the modelling of antenna radomes for use in wireless communications. - Graphical abstract:.

  6. Mode and climatic factors effect on energy losses in transient heat modes of transmission lines

    Science.gov (United States)

    Bigun, A. Ya; Sidorov, O. A.; Osipov, D. S.; Girshin, S. S.; Goryunov, V. N.; Petrova, E. V.

    2018-01-01

    Electrical energy losses increase in modern grids. The losses are connected with an increase in consumption. Existing models of electric power losses estimation considering climatic factors do not allow estimating the cable temperature in real time. Considering weather and mode factors in real time allows to meet effectively and safely the consumer’s needs to minimize energy losses during transmission, to use electric power equipment effectively. These factors increase an interest in the evaluation of the dynamic thermal mode of overhead transmission lines conductors. The article discusses an approximate analytic solution of the heat balance equation in the transient operation mode of overhead lines based on the least squares method. The accuracy of the results obtained is comparable with the results of solving the heat balance equation of transient thermal mode with the Runge-Kutt method. The analysis of mode and climatic factors effect on the cable temperature in a dynamic thermal mode is presented. The calculation of the maximum permissible current for variation of weather conditions is made. The average electric energy losses during the transient process are calculated with the change of wind, air temperature and solar radiation. The parameters having the greatest effect on the transmission capacity are identified.

  7. The Atlas pulsed power facility for high energy density physics experiments

    CERN Document Server

    Miller, R B; Barr, G W; Bowman, D W; Cochrane, J C; Davis, H A; Elizondo, J M; Gribble, R F; Griego, J R; Hicks, R D; Hinckley, W B; Hosack, K W; Nielsen, K E; Parker, J V; Parsons, M O; Rickets, R L; Salazar, H R; Sánchez, P G; Scudder, D W; Shapiro, C; Thompson, M C; Trainor, R J; Valdez, G A; Vigil, B N; Watt, R G; Wysocki, F J; Kirbie, H C

    1999-01-01

    The Atlas facility, now under construction at Los Alamos National Laboratory (LANL), will provide a unique capability for performing high-energy-density experiments in support of weapon-physics and basic-research programs. Here, the authors describe how the primary element of Atlas is a 23-MJ capacitor bank, comprised of 96 separate Marx generators housed in 12 separate oil-filled tanks, surrounding a central target chamber. Each tank will house two, independently- removable maintenance units, with each maintenance unit consisting of four Marx modules. Each Marx module has four capacitors that can each be charged to a maximum of 60 kilovolts. When railgap switches are triggered, the Marx modules erect to a maximum of 240 kV. The parallel discharge of these 96 Marx modules will deliver a 30-MA current pulse with a 4-5-ys risetime to a cylindrical, imploding liner via 24 vertical, tri-plate, oil-insulated transmission lines. An experimental program for testing and certifying all Marx and transmission line compo...

  8. Measurement and diagnosis system for 1.2 MV repetitive pulsed power source

    International Nuclear Information System (INIS)

    Li Yawei; Deng Jianjun; Xie Min; Feng Zongming; Liu Yuntao; Ma Chenggang

    2010-01-01

    In order to analyze the discharge performance and improve the design of the power system, a set of measurement and diagnosis system for the 1.2 MV repetitive pulsed power source, which supplies the drive power for a high power microwave source, has been designed by studying the high-voltage, high-current testing technology, data acquisition, signal processing, fault diagnosis, virtual instruments and electromagnetic compatibility technology, etc. A resistive-capacitive divider and a Rogowski coil are adopted in measurement; ADLINK corporation's PXI chips are used in data acquisition; data transmission system, condition monitoring and data analysis are developed by LabVIEW. This system can realize on-line monitoring and data analysis for the repetitive pulsed power source. (authors)

  9. Development of the pulse transformer for NLC klystron pulse modulator

    International Nuclear Information System (INIS)

    Akemoto, M.; Gold, S.; Koontz, R.; Krasnykh, A.

    1997-05-01

    We have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250ns and pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests are also presented

  10. Theoretical investigation of dielectric corona pre-ionization TEA nitrogen laser based on transmission line method

    Science.gov (United States)

    Bahrampour, Alireza; Fallah, Robabeh; Ganjovi, Alireza A.; Bahrampour, Abolfazl

    2007-07-01

    This paper models the dielectric corona pre-ionization, capacitor transfer type of flat-plane transmission line traveling wave transverse excited atmospheric pressure nitrogen laser by a non-linear lumped RLC electric circuit. The flat-plane transmission line and the pre-ionizer dielectric are modeled by a lumped linear RLC and time-dependent non-linear RC circuit, respectively. The main discharge region is considered as a time-dependent non-linear RLC circuit where its resistance value is also depends on the radiated pre-ionization ultra violet (UV) intensity. The UV radiation is radiated by the resistance due to the surface plasma on the pre-ionizer dielectric. The theoretical predictions are in a very good agreement with the experimental observations. The electric circuit equations (including the ionization rate equations), the equations of laser levels population densities and propagation equation of laser intensities, are solved numerically. As a result, the effects of pre-ionizer dielectric parameters on the electrical behavior and output laser intensity are obtained.

  11. On-line statistical processing of radiation detector pulse trains with time-varying count rates

    International Nuclear Information System (INIS)

    Apostolopoulos, G.

    2008-01-01

    Statistical analysis is of primary importance for the correct interpretation of nuclear measurements, due to the inherent random nature of radioactive decay processes. This paper discusses the application of statistical signal processing techniques to the random pulse trains generated by radiation detectors. The aims of the presented algorithms are: (i) continuous, on-line estimation of the underlying time-varying count rate θ(t) and its first-order derivative dθ/dt; (ii) detection of abrupt changes in both of these quantities and estimation of their new value after the change point. Maximum-likelihood techniques, based on the Poisson probability distribution, are employed for the on-line estimation of θ and dθ/dt. Detection of abrupt changes is achieved on the basis of the generalized likelihood ratio statistical test. The properties of the proposed algorithms are evaluated by extensive simulations and possible applications for on-line radiation monitoring are discussed

  12. Transmission line theory for long plasma production by radio frequency discharges between parallel-plate electrodes

    International Nuclear Information System (INIS)

    Nonaka, S.

    1991-01-01

    In order to seek for a radio frequency (RF) eigen-mode of waves in producing a plasma between a pair of long dielectric-covered parallel-plate RF electrodes, this paper analyzed all normal modes propagating along the electrodes by solving Maxwell's equations. The result showed that only an odd surface wave mode will produce the plasma in usual experimental conditions, which will become a basic transmission line theory when use of such long electrodes for on-line mass-production of amorphous silicon solar cells

  13. Termination for a superconducting power transmission line including a horizontal cryogenic bushing

    Science.gov (United States)

    Minati, Kurt F.; Morgan, Gerry H.; McNerney, Andrew J.; Schauer, Felix

    1984-01-01

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminates the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  14. Efficient production of hot plasmas through multiple-wire implosion in transmission line generators

    International Nuclear Information System (INIS)

    Bloomberg, H.W.

    1980-01-01

    Model equations for the implosion of multiple-wire arrays mounted across the electrodes of a transmission line generator are used to obtain an expression for the energy-coupling efficiency. For a useful class of imploding loads, the efficiency is shown to depend on a single dimensionless parameter. Furthermore, the efficiency curve has a maximum, and this permits an explicit optimization of the wire load parameters in terms of the machine parameters

  15. Evaluation of the probability of arrester failure in a high-voltage transmission line using a Q learning artificial neural network model

    International Nuclear Information System (INIS)

    Ekonomou, L; Karampelas, P; Vita, V; Chatzarakis, G E

    2011-01-01

    One of the most popular methods of protecting high voltage transmission lines against lightning strikes and internal overvoltages is the use of arresters. The installation of arresters in high voltage transmission lines can prevent or even reduce the lines' failure rate. Several studies based on simulation tools have been presented in order to estimate the critical currents that exceed the arresters' rated energy stress and to specify the arresters' installation interval. In this work artificial intelligence, and more specifically a Q-learning artificial neural network (ANN) model, is addressed for evaluating the arresters' failure probability. The aims of the paper are to describe in detail the developed Q-learning ANN model and to compare the results obtained by its application in operating 150 kV Greek transmission lines with those produced using a simulation tool. The satisfactory and accurate results of the proposed ANN model can make it a valuable tool for designers of electrical power systems seeking more effective lightning protection, reducing operational costs and better continuity of service

  16. Evaluation of the probability of arrester failure in a high-voltage transmission line using a Q learning artificial neural network model

    Science.gov (United States)

    Ekonomou, L.; Karampelas, P.; Vita, V.; Chatzarakis, G. E.

    2011-04-01

    One of the most popular methods of protecting high voltage transmission lines against lightning strikes and internal overvoltages is the use of arresters. The installation of arresters in high voltage transmission lines can prevent or even reduce the lines' failure rate. Several studies based on simulation tools have been presented in order to estimate the critical currents that exceed the arresters' rated energy stress and to specify the arresters' installation interval. In this work artificial intelligence, and more specifically a Q-learning artificial neural network (ANN) model, is addressed for evaluating the arresters' failure probability. The aims of the paper are to describe in detail the developed Q-learning ANN model and to compare the results obtained by its application in operating 150 kV Greek transmission lines with those produced using a simulation tool. The satisfactory and accurate results of the proposed ANN model can make it a valuable tool for designers of electrical power systems seeking more effective lightning protection, reducing operational costs and better continuity of service.

  17. Transmission-line resonators for the study of individual two-level tunneling systems

    Science.gov (United States)

    Brehm, Jan David; Bilmes, Alexander; Weiss, Georg; Ustinov, Alexey V.; Lisenfeld, Jürgen

    2017-09-01

    Parasitic two-level tunneling systems (TLS) emerge in amorphous dielectrics and constitute a serious nuisance for various microfabricated devices, where they act as a source of noise and decoherence. Here, we demonstrate a new test bed for the study of TLS in various materials which provides access to properties of individual TLS as well as their ensemble response. We terminate a superconducting transmission-line resonator with a capacitor that hosts TLS in its dielectric. By tuning TLS via applied mechanical strain, we observe the signatures of individual TLS strongly coupled to the resonator in its transmission characteristics and extract the coupling components of their dipole moments and energy relaxation rates. The strong and well-defined coupling to the TLS bath results in pronounced resonator frequency fluctuations and excess phase noise, through which we can study TLS ensemble effects such as spectral diffusion, and probe theoretical models of TLS interactions.

  18. [Apoptosis of human lung carcinoma cell line GLC-82 induced by high power electromagnetic pulse].

    Science.gov (United States)

    Cao, Xiao-zhe; Zhao, Mei-lan; Wang, De-wen; Dong, Bo

    2002-09-01

    Electromagnetic pulse (EMP) could be used for sterilization of food and the efficiency is higher than 2450 MHz continuous microwave done. This study was designed to evaluate the effect of electromagnetic pulse (EMP) on apoptosis of human lung carcinoma cell line GLC-82, so that to explore and develop therapeutic means for cancer. The injury changes in GLC-82 cells after irradiated with EMP (electric field intensity was 60 kV/m, 5 pulses/2 min) were analyzed by cytometry, MTT chronometry, and flow cytometry. The immunohistochemical SP staining was used to determine the expressions of bcl-2 protein and p53 protein. The stained positive cells were analyzed by CMIAS-II image analysis system at a magnification 400. All data were analyzed by SPSS8.0 software. EMP could obviously inhibited proliferation and activity of lung carcinoma cell line GLC-82. The absorbance value (A570) of MTT decreased immediately, at 0 h, 1 h, and 6 h after the GLC-82 cells irradiated by EMP as compared with control group. The highest apoptosis rate was found to reach 13.38% by flow cytometry at 6 h after EMP irradiation. Down-regulation of bcl-2 expression and up-regulation of p53 expression were induced by EMP. EMP promotes apoptosis of GLC-82 cells. At same time, EMP can down-regulate bcl-2 expression and up-regulate p53 expression in GLC-82 cells. The bcl-2 and the p53 protein may involve the apoptotic process.

  19. Conducting to non-conducting transition in dual transmission lines using a ternary model with long-range correlated disorder

    International Nuclear Information System (INIS)

    Lazo, E.; Diez, E.

    2010-01-01

    In this work we study the behavior of the allowed and forbidden frequencies in disordered classical dual transmission lines when the values of capacitances {C j } are distributed according to a ternary model with long-range correlated disorder. We introduce the disorder from a random sequence with a power spectrum S(k)∝k -(2α-1) , where α≥0.5 is the correlation exponent. From this sequence we generate an asymmetric ternary map using two map parameters b 1 and b 2 , which adjust the occupancy probability of each possible value of the capacitances C j ={C A, C B, C C, }. If the sequence of capacitance values is totally at random α=0.5 (white noise), the electrical transmission line is in the non-conducting state for every frequency ω. When we introduce long-range correlations in the distribution of capacitances, the electrical transmission lines can change their conducting properties and we can find a transition from the non-conducting to conducting state for a fixed system size. This implies the existence of critical values of the map parameters for each correlation exponent α. By performing finite-size scaling we obtain the asymptotic value of the map parameters in the thermodynamic limit for any α. With these data we obtain a phase diagram for the symmetric ternary model, which separates the non-conducting state from the conducting one. This is the fundamental result of this Letter. In addition, introducing one or more impurities in random places of the long-range correlated distribution of capacitances, we observe a dramatic change in the conducting properties of the electrical transmission lines, in such a way that the system jumps from conducting to non-conducting states. We think that this behavior can be considered as a possible mechanism to secure communication.

  20. Vessel calibre and haemoglobin effects on pulse oximetry

    International Nuclear Information System (INIS)

    McEwen, M P; Reynolds, K J; Bull, G P

    2009-01-01

    Despite its success as a clinical monitoring tool, pulse oximetry may be improved with respect to the need for empirical calibration and the reports of biases in readings associated with peripheral vasoconstriction and haemoglobin concentration. To effect this improvement, this work aims to improve the understanding of the photoplethysmography signal—as used by pulse oximeters—and investigates the effect of vessel calibre and haemoglobin concentration on pulse oximetry. The digital temperature and the transmission of a wide spectrum of light through the fingers of 57 people with known haemoglobin concentrations were measured and simulations of the transmission of that spectrum of light through finger models were performed. Ratios of pulsatile attenuations of light as used in pulse oximetry were dependent upon peripheral temperature and on blood haemoglobin concentration. In addition, both the simulation and in vivo results showed that the pulsatile attenuation of light through fingers was approximately proportional to the absorption coefficients of blood, only when the absorption coefficients were small. These findings were explained in terms of discrete blood vessels acting as barriers to light transmission through tissue. Due to the influence of discrete blood vessels on light transmission, pulse oximeter outputs tend to be dependent upon haemoglobin concentration and on the calibre of pulsing blood vessels—which are affected by vasoconstriction/vasodilation. The effects of discrete blood vessels may account for part of the difference between the Beer–Lambert pulse oximetry model and empirical calibration

  1. Study of data transmission over drive motor power cables of a remotely operated robot using power line communication technology

    International Nuclear Information System (INIS)

    Balaji, Kanchi; Singh, Ashutosh Pratap; Rakesh, V.; Rajagopalan, C.; Murugan, S.

    2016-01-01

    In nuclear power plants (NPPs), robotic devices are widely used for carrying out in-service inspection (lSI) and repair tasks at elevated temperatures and radiation environments. These devices comprises servo motors that are powered and controlled by the motion control unit/electric drives. The control and inspection data are to be transmitted back from the inspection device to the control unit using separate industrial graded data transmission cables compatible for high temperature applications. This increases complexity of robot trailing cables and cost. Hence, it is proposed to use power cables that are used for powering the motor for sending information signals using power line communication (PLC) technology. The domestically used PLC modems adds noise to the information signal when coupled on to the motor feed cables during IGBT switching. Therefore, passive low pass filters are used at the motor drive end to reduce the impulsive noise. The aim of this study is to compare noise characteristics for different type of filter structures over pulse width modulation (PWM) network. We will highlight the choice of cut off frequency of filter based on frequency of information signal

  2. Support vector machine based fault classification and location of a long transmission line

    Directory of Open Access Journals (Sweden)

    Papia Ray

    2016-09-01

    Full Text Available This paper investigates support vector machine based fault type and distance estimation scheme in a long transmission line. The planned technique uses post fault single cycle current waveform and pre-processing of the samples is done by wavelet packet transform. Energy and entropy are obtained from the decomposed coefficients and feature matrix is prepared. Then the redundant features from the matrix are taken out by the forward feature selection method and normalized. Test and train data are developed by taking into consideration variables of a simulation situation like fault type, resistance path, inception angle, and distance. In this paper 10 different types of short circuit fault are analyzed. The test data are examined by support vector machine whose parameters are optimized by particle swarm optimization method. The anticipated method is checked on a 400 kV, 300 km long transmission line with voltage source at both the ends. Two cases were examined with the proposed method. The first one is fault very near to both the source end (front and rear and the second one is support vector machine with and without optimized parameter. Simulation result indicates that the anticipated method for fault classification gives high accuracy (99.21% and least fault distance estimation error (0.29%.

  3. Wideband Isolation by Frequency Conversion in a Josephson-Junction Transmission Line

    Science.gov (United States)

    Ranzani, Leonardo; Kotler, Shlomi; Sirois, Adam J.; DeFeo, Michael P.; Castellanos-Beltran, Manuel; Cicak, Katarina; Vale, Leila R.; Aumentado, José

    2017-11-01

    Nonreciprocal transmission and isolation at microwave frequencies are important in many practical applications. In particular, compact isolators are useful in protecting sensitive quantum circuits operating at cryogenic temperatures from amplifier backaction and other environmental noise such as black-body radiation from higher temperature stages. However, the size of commercial cryogenic isolators limits the ability to measure multiple quantum circuits because of space constraints in typical dilution refrigerator systems. Furthermore, isolators usually require the use of ferrite components that cannot be integrated at the chip level and, since they also need large biasing magnetic fields, are incompatible with superconducting quantum circuits. In this work we show one way to accomplish isolation in a superconducting chip-scale device, a traveling-wave unidirectional frequency converter based on a parametrically pumped superconducting Josephson-junction transmission line, demonstrating better than 4.8 dB of inferred signal isolation from 6.6 to 11.4 GHz, with a maximum of 12 dB at 9.5 GHz. By using frequency diplexing techniques a conventional isolator could be implemented over this bandwidth.

  4. Optical transmission control in graphene oxide and its organic composites with ultrashort laser pulses

    International Nuclear Information System (INIS)

    Bala Murali Krishna, M; Narayana Rao, D; Venkatramaiah, N

    2014-01-01

    Nonlinear optical transmission of graphene oxide–(Cu, Zn, Sn, H 2 ) porphyrin composites was investigated using the Z-scan technique at 532 nm with picosecond (ps) and 800 nm with femtosecond laser pulses. Pure porphyrins show saturable absorption (SA) in reverse saturable absorption (RSA) behaviour and graphene oxide shows complete RSA behaviour, observed in an open aperture Z-scan curve. Interestingly, composites have shown a switch-over from reverse RSA to SA and back to RSA behaviour, observed with variation of intensity towards the focus, due to strong two-photon absorption as well as excited state absorption in the ps regime. This switching behaviour was interpreted as due to long lifetimes and saturation of the excited states. This may find application in optical switching. (paper)

  5. Pulse transformer R and D for NLC klystron pulse modulator

    International Nuclear Information System (INIS)

    Akemoto, M.; Gold, S.; Krasnykh, A.; Koontz, R.

    1997-07-01

    The authors have studied a conventional pulse transformer for the NLC klystron pulse modulator. The transformer has been analyzed using a simplified lumped circuit model. It is found that a fast rise time requires low leakage inductance and low distributed capacitance and can be realized by reducing the number of secondary turns, but it produces larger pulse droop and requires a larger core size. After making a tradeoff among these parameters carefully, a conventional pulse transformer with a rise time of 250ns and a pulse droop of 3.6% has been designed and built. The transmission characteristics and pulse time-response were measured. The data were compared with the model. The agreement with the model was good when the measured values were used in the model simulation. The results of the high voltage tests using a klystron load are also presented

  6. The Experimental Verification of Gaussian Beam Coupling for ECH Transmission Line at 400 GHz

    Directory of Open Access Journals (Sweden)

    Choe Mun Seok

    2017-01-01

    Full Text Available We design a quasi-optical transmission line system for a 400 GHz gyrotron beam. The 400GHz Gaussian beam is injected to a corrugated waveguide bounced from a quasi-optical mirror. From detailed 2D field patterns of the output beam emitted from the corrugated waveguide, we analyze the mode contents and the source of non-ideal beam expansion

  7. Gain assisted coherent control of microwave pulse in a one dimensional array of artificial atoms

    Science.gov (United States)

    Waqas, Mohsin; Ayaz, M. Q.; Waseem, M.; Qamar, Sajid; Qamar, Shahid

    2018-06-01

    We study the coherent propagation of a microwave pulse through a one-dimensional array of artificial atoms. The scheme is based upon gain assisted propagation of the pulse using two-photon Raman transition in a three-level superconducting artificial atoms (SAAs) coupled to a microwave transmission line. Our results show that the group velocity can be significantly reduced by increasing the Rabi frequency of the pump fields which in turn can lead to an efficient storage of the pulse inside a 1D array of SAAs. Further, the intensity of the transmitted pulse increases with the number of artificial atoms owing to the gain associated with the two-photon Raman transition. Our results also show that the window width decreases for both scattering and negligible scattering cases with the increase in the number of SAAs. The fidelity of the system also remains high even after the passage of the pulse through a large number of SAAs.

  8. Asymmetries of the solar Ca II lines

    International Nuclear Information System (INIS)

    Heasley, J.N.

    1975-01-01

    A theoretical study of the influence of propagating acoustic pulses in the solar chromosphere upon the line profiles of the Ca II resonance and infrared triplet lines has been made. The major objective has been to explain the observed asymmetries seen in the cores of the H and K lines and to predict the temporal behavior of the infrared lines caused by passing acoustic or shock pulses. The velocities in the pulses, calculated from weak shock theory, have been included consistently in the non-LTE calculations. The results of the calculations show that these lines are very sensitive to perturbations in the background atmosphere caused by the pulses. Only minor changes in the line shapes result from including the velocities consistently in the line source function calculations. The qualitative changes in the line profiles vary markedly with the strength of the shock pulses. The observed differences in the K line profiles seen on the quiet Sun can be explained in terms of a spectrum of pulses with different wavelengths and initial amplitudes in the photosphere. (Auth.)

  9. A modular restoration tower for electric power line transmission

    Energy Technology Data Exchange (ETDEWEB)

    Nicolazzi, L.C.; Pereira, J.C.; Leonel, C.E.L.; Rocha, G.B.; Bianchezzi, V.; Mendes, F. [Universidade Federal Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica], Emails: lauro@grante.ufsc.br, jcarlos@grante.ufsc.br; Luz, R.L. [ELETROSUL Centrais Eletricas S.A., Florianopolis, SC (Brazil)], Email: rluz@eletrosul.gov.br

    2009-07-01

    The main target of this R and D project is to develop an restoration tower for electric energy lines transmission. Whereas these towers should present the main features like transport facility, easiest assembling associated with a low cost of manufacture, it was applied the single-column tower concepts supported by stays, modularized, framed and articulated at the base. The concepts used for this development was a design methodology. From the different definition situations of load, numerical models have been developed focusing the design to the best of structural element arrangements of its modules. Then, tests were performed in laboratory to determine the module structural performance for different work load situations. These tests served to identify inconsistencies in the numerical models and proposed adjustments in its design to improve its performance on the strength and stability. (author)

  10. A Smart Grid Framework for Optimally Integrating Supply-Side, Demand-Side and Transmission Line Management Systems

    Directory of Open Access Journals (Sweden)

    Chukwuka Monyei

    2018-04-01

    Full Text Available A coordinated centralized energy management system (ConCEMS is presented in this paper that seeks to integrate for optimal grid operation—the supply side energy management system (SSEMS, home energy management system (HEMS and transmission line management system (TLMS. ConCEMS in ensuring the optimal operation of an IEEE 30-bus electricity network harmonizes the individual objective function of SSEMS, HEMS and TLMS to evolve an optimal dispatch of participating demand response (DR loads that does not violate transmission line ampacity limits (TLMS constraint while minimizing consumer cost (HEMS constraint and supply side operations cost (SSEMS constraint. An externally constrained genetic algorithm (ExC-GA that is influenced by feedback from TLMS is also presented that intelligently varies the dispatch time of participating DR loads to meet the individual objective functions. Hypothetical day ahead dynamic pricing schemes (Price1, Price2 and Price3 have also been adopted alongside an existing time of use (Price0 pricing scheme for comparison and discussion while a dynamic thermal line rating (DTLR algorithm has also been incorporated to dynamically compute power limits based on real time associated data.

  11. Polymeric electrochemical element for adaptive networks: Pulse mode

    International Nuclear Information System (INIS)

    Smerieri, Anteo; Berzina, Tatiana; Erokhin, Victor; Fontana, M. P.

    2008-01-01

    An electrochemically controlled polymeric heterojunction working as a memristor, i.e., having memory properties, was investigated in pulse mode, mimicking synaptic behavior of signal transmission in biological systems. Influence of parameters such as pulse duration, interval between pulses, and value of potential base level was analyzed. Learning capabilities were shown to be reversible and repeatable for both potentiation and inhibition of signal transmission. The adaptive behavior of the element was investigated and was shown to be more efficient than the dc mode

  12. Effects of Pulsed Electromagnetic Field on Differentiation of HUES-17 Human Embryonic Stem Cell Line

    Directory of Open Access Journals (Sweden)

    Yi-Lin Wu

    2014-08-01

    Full Text Available Electromagnetic fields are considered to potentially affect embryonic development, but the mechanism is still unknown. In this study, human embryonic stem cell (hESC line HUES-17 was applied to explore the mechanism of exposure on embryonic development to pulsed electromagnetic field (PEMF for 400 pulses at different electric field intensities and the differentiation of HUES-17 cells was observed after PEMF exposure. The expression of alkaline phosphatase (AP, stage-specific embryonic antigen-3 (SSEA-3, SSEA-4 and the mRNA level and protein level of Oct4, Sox2 and Nanog in HUES-17 cells remained unchanged after PEMF exposure at the electric field intensities of 50, 100, 200 or 400 kV/m. Four hundred pulses PEMF exposure at the electric field intensities of 50, 100, 200 or 400 kV/m did not affect the differentiation of HUES-17 cells. The reason why electromagnetic fields affect embryonic development may be due to other mechanisms rather than affecting the differentiation of embryonic stem cells.

  13. Study of electric and magnetic fields on transmission lines using a computer simulation program

    International Nuclear Information System (INIS)

    Robelo Mojica, Nelson

    2011-01-01

    A study was conducted to determine and reduce levels of electric and magnetic fields with different configurations used by the Instituto Costarricense de Electricidad in power transmission lines in Costa Rica. The computer simulation program PLS-CADD with EPRI algorithm has been used to obtain field values close to those actual to lines easements that have worked to date. Different configurations have been compared on equal terms and the lowest levels of electric and magnetic fields are determined. The most appropriate configuration of the tower has been obtained and therefore has decreased exposure to electromagnetic fields people, without affecting the energy demand of the population. (author) [es

  14. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-106)SnoKing Tap to Monroe-Samamish Line

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Mark A. [Bonneville Power Administration, Portland, OR (United States)

    2002-09-30

    Vegetation Management along the SnoKing Tap to the Monroe-Samamish transmission line from structure 8/1 through structure 20/6. BPA proposes to remove unwanted vegetation along the right-of-way, access roads and around tower structures along the subject transmission line corridor. The right-of-way will be treated using selective and non-selective methods that include hand cutting, mowing and herbicide treatments. Approximately 12 miles of access roads will be cleared using selective and non-selective methods that include hand cutting, mowing and herbicide treatments. Approximately 65 tower sites will be treated using selective and non-selective methods that include hand cutting, mowing and herbicide treatments. Vegetation management is required for unimpeded operation and maintenance of the subject transmission line. See Section 1of the attached checklist for a complete description of the proposal.

  15. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines.

    Science.gov (United States)

    Mazur, Katarzyna; Wydra, Michal; Ksiezopolski, Bogdan

    2017-07-11

    Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs) as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Network (WSN) for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs.

  16. Method and apparatus for magnetic resonance imaging and spectroscopy using microstrip transmission line coils

    Science.gov (United States)

    Zhang, Xiaoliang; Ugurbil, Kamil; Chen, Wei

    2006-04-04

    Apparatus and method for MRI imaging using a coil constructed of microstrip transmission line (MTL coil) are disclosed. In one method, a target is positioned to be imaged within the field of a main magnetic field of a magnet resonance imaging (MRI) system, a MTL coil is positioned proximate the target, and a MRI image is obtained using the main magnet and the MTL coil. In another embodiment, the MRI coil is used for spectroscopy. MRI imaging and spectroscopy coils are formed using microstrip transmission line. These MTL coils have the advantageous property of good performance while occupying a relatively small space, thus allowing MTL coils to be used inside restricted areas more easily than some other prior art coils. In addition, the MTL coils are relatively simple to construct of inexpensive components and thus relatively inexpensive compared to other designs. Further, the MTL coils of the present invention can be readily formed in a wide variety of coil configurations, and used in a wide variety of ways. Further, while the MTL coils of the present invention work well at high field strengths and frequencies, they also work at low frequencies and in low field strengths as well.

  17. Bipolar pulse generator for intense pulsed ion beam accelerator

    International Nuclear Information System (INIS)

    Ito, H.; Igawa, K.; Kitamura, I.; Masugata, K.

    2007-01-01

    A new type of pulsed ion beam accelerator named ''bipolar pulse accelerator'' (BPA) has been proposed in order to improve the purity of intense pulsed ion beams. To confirm the principle of the BPA, we developed a bipolar pulse generator for the bipolar pulse experiment, which consists of a Marx generator and a pulse forming line (PFL) with a rail gap switch on its end. In this article, we report the first experimental result of the bipolar pulse and evaluate the electrical characteristics of the bipolar pulse generator. When the bipolar pulse generator was operated at 70% of the full charge condition of the PFL, the bipolar pulse with the first (-138 kV, 72 ns) and the second pulse (+130 kV, 70 ns) was successfully obtained. The evaluation of the electrical characteristics indicates that the developed generator can produce the bipolar pulse with fast rise time and sharp reversing time

  18. Production and guide tube transmission of very cold neutrons from pulsed cold source

    International Nuclear Information System (INIS)

    Utsuro, Masahiko; Okumura, Kiyoshi

    1982-01-01

    The intensity and the energy spectra of Very Cold Neutrons (VCN) transmitted through a curved guide tube were measured by using the time-of-flight method of VCN. In the measurements, the curved guide tube having a characteristic neutron velocity of about 70 m/s is combined to a pulsed cold source of an electron linac in an internal target geometry. A space dependence of the VCN spectra was observed on the radial positions of a detector at the guide tube exit. A simple theoretical analysis on the transmission of VCN in the curved guide tube is also presented with taking into consideration about the effects of a finite size and a finite distance of the VCN-emitting source, and simple analytical formulas for the exit spectra of the guide tube are given. Comparisons between the experimental results and the theoretical calculations show good agreements, and the satisfactory performance of the present VCN guide tube assembly was ascertained. These results present also instructive features for understanding the structures and the space dependence of the exit spectra of a neutron guide tube. The VCN spectra at the guide tube exit can be divided into a few energy regions according to the transmission processes of VCN. Thus, the present study provides useful informations for the preparations of a VCN source with a curved guide tube. (author)

  19. Improving the output voltage waveform of an intense electron-beam accelerator based on helical type Blumlein pulse forming line

    Directory of Open Access Journals (Sweden)

    Xin-Bing Cheng

    2010-07-01

    Full Text Available The Blumlein pulse forming line (BPFL consisting of an inner coaxial pulse forming line (PFL and an outer coaxial PFL is widely used in the field of pulsed power, especially for intense electron-beam accelerators (IEBA. The output voltage waveform determines the quality and characteristics of the output beam current of the IEBA. Comparing with the conventional BPFL, an IEBA based on a helical type BPFL can increase the duration of the output voltage in the same geometrical volume. However, for the helical type BPFL, the voltage waveform on a matched load may be distorted which influences the electron-beam quality. In this paper, an IEBA based on helical type BPFL is studied theoretically. Based on telegrapher equations of the BPFL, a formula for the output voltage of IEBA is obtained when the transition section is taken into account, where the transition section is between the middle cylinder of BPFL and the load. From the theoretical analysis, it is found that the wave impedance and transit time of the transition section influence considerably the main pulse voltage waveform at the load, a step is formed in front of the main pulse, and a sharp spike is also formed at the end of the main pulse. In order to get a well-shaped square waveform at the load and to improve the electron-beam quality of such an accelerator, the wave impedance of the transition section should be equal to that of the inner PFL of helical type BPFL and the transit time of the transition section should be designed as short as possible. Experiments performed on an IEBA with the helical type BPFL show reasonable agreement with theoretical analysis.

  20. Ultrasonic monitoring system

    International Nuclear Information System (INIS)

    McLain, R.E.

    1975-01-01

    The ultrasonic monitoring system is used in LMFBR's, BWR's or PWR's. A remotely controlled, movable instrument carrier may be used which contains the piezo-electric transducer and is connected to the main control console by a transmission cable. An excitation pulse coming from a pulse generator is used to excite the transducer with a maximum of energy, independent of the length of the transmission line. Pulse width and pulse amplitude can be set without any direct interference into the transducer. For this purpose, a resistor whose impedance has been matched to that of the transmission line is connected to the input of the transmission line. Moreover, a capacitor for generation of the excitation pulse is coupled with the transmission line by means of a four-layer switching diode and is discharged. For termination of the excitation and the control pulses, respectively, another four-layer switching diode connected parallel to the capacitor quickly discharges the capacitor. The capacitor and the capacitance of the line constitute a voltage divider. In this way it is possible to change the length of the transmission line and, to safeguard the generation of a pulse of the desired amplitude, only vary the capacitance of the capacitor. (DG/RF) [de

  1. A vacuum-sealed, gigawatt-class, repetitively pulsed high-power microwave source

    Science.gov (United States)

    Xun, Tao; Fan, Yu-wei; Yang, Han-wu; Zhang, Zi-cheng; Chen, Dong-qun; Zhang, Jian-de

    2017-06-01

    A compact L-band sealed-tube magnetically insulated transmission line oscillator (MILO) has been developed that does not require bulky external vacuum pump for repetitive operations. This device with a ceramic insulated vacuum interface, a carbon fiber array cathode, and non-evaporable getters has a base vacuum pressure in the low 10-6 Pa range. A dynamic 3-D Monte-Carlo model for the molecular flow movement and collision was setup for the MILO chamber. The pulse desorption, gas evolution, and pressure distribution were exactly simulated. In the 5 Hz repetition rate experiments, using a 600 kV diode voltage and 48 kA beam current, the average radiated microwave power for 25 shots is about 3.4 GW in 45 ns pulse duration. The maximum equilibrium pressure is below 4.0 × 10-2 Pa, and no pulse shortening limitations are observed during the repetitive test in the sealed-tube condition.

  2. Antenna Parts and Waveguide Transmission Line of Short Pulse Radar System Design

    Directory of Open Access Journals (Sweden)

    M. E. Golubcov

    2014-01-01

    Full Text Available The main point of this research was работы являлось to create a stand to explore the application of short pulse radio signals in radar. The stand consists of antenna and waveguide elements. Each element out to guarantee operation in X-band with 10 percent working bank and 5 percent instantaneous bandwidth and the power output gotta be 1.5 kW. The form of the antenna beam patten need to be similar to cosecant pattern Side-lobe level need to be less than -25 dB. Background level got to be at least -30 dB. Wave friction, which is radiated from the antenna aperture, got to simultaneous formed in a space.As the most easily realizing variant of such antenna cutting parabolic mirror antenna with offset irradiator was chosen. The irradiator phase centre is shifted from the focal point of the paraboloid to form a cosecant pattern. Method of physical optics is used for the analysis of antennas. Calculating pattern of horn irradiator and mirror antenna which were met the requirements was received. The construction choice was limited by the preproduction possibilities, mass and dimensions. Mirror antenna consists of skeleton framing with mirroring elements which are fixing on it. Mirroring plane is multiplex and consists off rectangular planes made by hydroforming method. Antenna was tested and adjusted at the antenna darkroom after fabricating. The results were meted requirements.Besides the mirror antenna and the horn antenna waveguide elements, waveguide bends and rotating joints were calculated, manufactured and researched. All calculations included the manufacturers tolerances, technological corner R etc. As the construction base of rotating joint coaxial waveguide was chosen. The decision on the one hand: let keep the axial symmetry of excited wave at rotating part of the waveguide, on the other hand there’s no necessary to apply resonant rings, which are plug into dielectric beads for the transition from rotating ring part to

  3. Pricing transmission services

    International Nuclear Information System (INIS)

    Haaden, E.

    1995-01-01

    The price structure for transmission of electric power through the main lines in Sweden is analyzed. After deregulation of the electricity market, the main transmission lines are owned by a separate national company, with no interests from the power producers. Comparisons are made to ideal marginal price structures. 6 refs

  4. Distance protection of multiple-circuit shared tower transmission lines with different voltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. This study presents a detailed theoretical analysis of such combined faults, including the development...... of a formula for estimating the magnitude of the short-circuit current. It is demonstrated that if the faulted phase from the higher voltage level leads the faulted phase from the lower voltage level, a distance relay at the higher voltage level sees the fault in the forward direction, whereas a distance relay...

  5. PIC simulation of the vacuum power flow for a 5 terawatt, 5 MV, 1 MA pulsed power system

    Science.gov (United States)

    Liu, Laqun; Zou, Wenkang; Liu, Dagang; Guo, Fan; Wang, Huihui; Chen, Lin

    2018-03-01

    In this paper, a 5 Terawatt, 5 MV, 1 MA pulsed power system based on vacuum magnetic insulation is simulated by the particle-in-cell (PIC) simulation method. The system consists of 50 100-kV linear transformer drive (LTD) cavities in series, using magnetically insulated induction voltage adder (MIVA) technology for pulsed power addition and transmission. The pulsed power formation and the vacuum power flow are simulated when the system works in self-limited flow and load-limited flow. When the pulsed power system isn't connected to the load, the downstream magnetically insulated transmission line (MITL) works in the self-limited flow, the maximum of output current is 1.14 MA and the amplitude of voltage is 4.63 MV. The ratio of the electron current to the total current is 67.5%, when the output current reached the peak value. When the impedance of the load is 3.0 Ω, the downstream MITL works in the self-limited flow, the maximums of output current and the amplitude of voltage are 1.28 MA and 3.96 MV, and the ratio of the electron current to the total current is 11.7% when the output current reached the peak value. In addition, when the switches are triggered in synchronism with the passage of the pulse power flow, it effectively reduces the rise time of the pulse current.

  6. Validation of the design of small diameter pulsed columns for the process line DRA. Tests reliability compared with the industrial scale

    International Nuclear Information System (INIS)

    Leybros, J.

    2000-01-01

    As part of the Spin program related to the management of nuclear wastes, studies have been undertaken to develop partitioning processes like Diamex process. The process line CCBP/DRA in Atalante facility forms one of the main equipment devoted to these studies. On this line industrial apparatus are used but some like pulsed columns need to be adapted because of the specificity of the installation: limiting amount of nuclear matter, gaseous waste minimization, safety, limiting amounts of new extractants,... This article presents the comparison of 2 air pulsed columns, one with a standard diameter of 25 (DN25), the other with a reduced diameter of 15 (DN15). This comparison is based on 3 main criteria: pulsation capability, superficial throughput and mass transfer efficiency. The overall comparison shows that a DN15 pulsed column can be considered as a representative tool of research and development. Particularly, the study demonstrates the possibility of scaling up the results

  7. Line facilities outline

    International Nuclear Information System (INIS)

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  8. Accurate fault location algorithm on power transmission lines with use of two-end unsynchronized measurements

    Directory of Open Access Journals (Sweden)

    Mohamed Dine

    2012-01-01

    Full Text Available This paper presents a new approach to fault location on power transmission lines. This approach uses two-end unsynchronised measurements of the line and benefits from the advantages of digital technology and numerical relaying, which are available today and can easily be applied for off-line analysis. The approach is to modify the apparent impedance method using a very simple first-order formula. The new method is independent of fault resistance, source impedances and pre-fault currents. In addition, the data volume communicated between relays is sufficiently small enough to be transmitted easily using a digital protection channel. The proposed approach is tested via digital simulation using MATLand the applied test results corroborate the superior performance of the proposed approach.

  9. High power semiconductor switches in the 12 kV, 50 kA pulse generator of the SPS beam dump kicker system

    CERN Document Server

    Bonthond, J; Faure, P; Vossenberg, Eugène B

    2001-01-01

    Horizontal deflection of the beam in the dump kicker system of the CERN SPS accelerator is obtained with a series of fast pulsed magnets. The high current pulses of 50 kA per magnet are generated with capacitor discharge type generators which, combined with a resistive free-wheel diode circuit, deliver a critically damped half-sine current with a rise-time of 25 ms. Each generator consists of two 25 kA units, connected in parallel to a magnet via a low inductance transmission line.

  10. Transmission line analysis of beam deflection in a BPM stripline kicker

    International Nuclear Information System (INIS)

    Caporaso, G.J.; Chen, Yu Ju; Poole, B.

    1997-05-01

    In the usual treatment of impedances of beamline structures the electromagnetic response is computed under the assumption that the source charge trajectory is parallel to the propagation axis and is unaffected by the wake of the structure. For high energy beams of relatively low current this is generally a valid assumption. Under certain conditions the assumption of a parallel source charge trajectory is no longer valid and the effects of the changing trajectory must be included in the analysis. Here the usual transmission line analysis that has been applied to BPM type transverse kickers is extended to include the self-consistent motion of the beam in the structure

  11. Multi-band Microwave Antennas and Devices based on Generalized Negative-Refractive-Index Transmission Lines

    Science.gov (United States)

    Ryan, Colan Graeme Matthew

    Focused on the quad-band generalized negative-refractive-index transmission line (G-NRI-TL), this thesis presents a variety of novel printed G-NRI-TL multi-band microwave device and antenna prototypes. A dual-band coupled-line coupler, an all-pass G-NRI-TL bridged-T circuit, a dual-band metamaterial leaky-wave antenna, and a multi-band G-NRI-TL resonant antenna are all new developments resulting from this research. In addition, to continue the theme of multi-band components, negative-refractive-index transmission lines are used to create a dual-band circularly polarized transparent patch antenna and a two-element wideband decoupled meander antenna system. High coupling over two independently-specified frequency bands is the hallmark of the G-NRI-TL coupler: it is 0.35lambda0 long but achieves approximately -3 dB coupling over both bands with a maximum insertion loss of 1 dB. This represents greater design flexibility than conventional coupled-line couplers and less loss than subsequent G-NRI-TL couplers. The single-ended bridged-T G-NRI-TL offers a metamaterial unit cell with an all-pass magnitude response up to 8 GHz, while still preserving the quad-band phase response of the original circuit. It is shown how the all-pass response leads to wider bandwidths and improved matching in quad-band inverters, power dividers, and hybrid couplers. The dual-band metamaterial leaky-wave antenna presented here was the first to be reported in the literature, and it allows broadside radiation at both 2 GHz and 6 GHz without experiencing the broadside stopband common to conventional periodic antennas. Likewise, the G-NRI-TL resonant antenna is the first reported instance of such a device, achieving quad-band operation between 2.5 GHz and 5.6 GHz, with a minimum radiation efficiency of 80%. Negative-refractive-index transmission line loading is applied to two devices: an NRI-TL meander antenna achieves a measured 52% impedance bandwidth, while a square patch antenna incorporates

  12. Cryogenic Fiber Optic Sensors for Superconducting Magnets and Power Transmission Lines in High Energy Physics Applications

    CERN Document Server

    AUTHOR|(CDS)2081689; Bajko, Marta

    In the framework of the Luminosity upgrade of the Large Hadron Collider (HL - LHC), a remarkable R&D effort is now ongoing at the European Organization for Nuclear Research (CERN) in order to develop a new generation of accelerator magnets and superconducting power transmission lines. The magnet technology will be based on Nb$_{3}$Sn enabling to operate in the 11 - 13 T range. In parallel, in order to preserve the power converters from the increasing radiation level, high power transmission lines are foreseen to feed the magnets from free - radiation zones. These will be based on high temperature superconductors cooled down with helium gas in the range 5 - 30 K. The new technologies will require advanced design and fabrication approaches as well as adapted instrumentation for monitoring both the R&D phase and operation. Resistive sensors have been used so far for voltage, temperature and strain monitoring but their integration still suffers from the number of electrical wires and the complex compensat...

  13. Pulsed rf excited spectrometer having improved pulse width control

    International Nuclear Information System (INIS)

    1977-01-01

    RF excitation for a spectrometer is obtained by pulse width modulating an RF carrier to produce the desired broadband RF exciting spectrum. The RF excitation includes a train of composite RF pulses, each composite pulse having a primary pulse portion of a first RF phase and a second pulse portion of a second RF phase opposite that of the first. In this manner, the finite rise and fall times of the primary pulse portion are compensated for by the corresponding rise and fall times of the secondary pulse portion. The primary pulse portion is lengthened by an amount equal to the secondary pulse portion so that the secondary pulse portion cancels the added primary pulse portion. In a spectrometer, the compensating second pulse component removes certain undesired side bands of the RF excitation caused by the finite rise and fall times of the applied RF pulses. The compensating second pulse component removes certain undesired side bands associated with each of the resonant lines of the excited resonance spectrum of the sample under analysis, particularly for wide band RF excitation

  14. Decision support for mitigating the risk of tree induced transmission line failure in utility rights-of-way.

    Science.gov (United States)

    Poulos, H M; Camp, A E

    2010-02-01

    Vegetation management is a critical component of rights-of-way (ROW) maintenance for preventing electrical outages and safety hazards resulting from tree contact with conductors during storms. Northeast Utility's (NU) transmission lines are a critical element of the nation's power grid; NU is therefore under scrutiny from federal agencies charged with protecting the electrical transmission infrastructure of the United States. We developed a decision support system to focus right-of-way maintenance and minimize the potential for a tree fall episode that disables transmission capacity across the state of Connecticut. We used field data on tree characteristics to develop a system for identifying hazard trees (HTs) in the field using limited equipment to manage Connecticut power line ROW. Results from this study indicated that the tree height-to-diameter ratio, total tree height, and live crown ratio were the key characteristics that differentiated potential risk trees (danger trees) from trees with a high probability of tree fall (HTs). Products from this research can be transferred to adaptive right-of-way management, and the methods we used have great potential for future application to other regions of the United States and elsewhere where tree failure can disrupt electrical power.

  15. A two-dimensional uniplanar transmission-line metamaterial with a negative index of refraction

    International Nuclear Information System (INIS)

    Elek, Francis; Eleftheriades, George V

    2005-01-01

    A uniplanar transmission-line (TL) network has been loaded with lumped elements (chip or printed), enabling one to achieve a two-dimensional (2D) uniplanar negative-refractive-index (NRI) metamaterial. The metamaterial consists of a 2D array of unit cells, composed of TL sections connected in series and loaded in a specified manner. The unit cell dimensions can be designed to be much smaller than the operating wavelength, enabling one to identify the structure as an effective medium, with a negative index of refraction. This NRI metamaterial supports transverse electric (TE) waves, as opposed to related previous work on NRI-TL media that supported transverse magnetic (TM) waves. The dispersion characteristics are calculated using a simple, fast 2D loaded TL model with periodic (Bloch) boundary conditions. Subsequently the dispersion relation is simplified in the homogeneous limit, thus allowing one to identify effective permittivities and permeabilities, which are shown to be simultaneously negative. Simulations demonstrating the negative refraction of a plane wave on an interface between such a NRI uniplanar metamaterial and a commensurate positive-refractive-index (PRI) metamaterial verify the validity of the proposed concept and theory. A fully printed unit cell is presented at microwave frequencies (∼10 GHz) along with a prescription for synthesizing an isotropic 3D transmission line NRI metamaterial based on this unit cell

  16. RIIM two-pulse injector experiments

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Smith, D.L.; Jones, E.E.; Hasti, D.E.; Jojola, J.M.; Lehmann, M.

    1987-01-01

    The RADLAC-II foilless diode injector was operated under double pulse conditions utilizing the RIIM accelerator as the test bed. The original RIIM accelerator pulse-power network was modified to provide for the generation, transmission, and delivery to the foilless diode of two distinct voltage pulses with variable interpulse separation from 0 to 2 ms. Two pulse-power assemblies were investigated and will be presented in connection with the diode performance. In both cases, the generated plasma and an excessive neutral gas release, following the first pulse, prevented the diode from producing a second beam pulse for interpulse separations larger than ∼1 μs. 4 refs

  17. Flatiron-Erie 115kV transmission line project, Larimer, Weld and Boulder Counties, Colorado

    International Nuclear Information System (INIS)

    1993-05-01

    Western Area Power Administration (Western) proposes to uprate its existing 115-kV Flatiron-Erie transmission line. The line is located in Larimer, Weld and Boulder Counties, Colorado, and passes through the City of Longmont. The line connects Flatiron Substation and several of the substations supplying Longmont. It is a single circuit 115-kV line, 31.5 miles long, and was built in 1950-51 on a 75-foot wide right-of-way (ROW) using wood H-frame structures. Western proposes to build 27 new structures along the line, to replace or modify 45 of the existing structures and to remote 11 of them. Many of these additions and changes would involve structures that are approximately 5 to 15 feet taller than the existing ones. The existing conductors and ground wires would remain in place. The purpose of these actions would be to allow the power carrying capability of the line to be increased and to replace deteriorating/structural members. Western would be the sole participant in the proposed project. This report gives an analysis of the study area environment and the development of alternative routes. An assessment is presented of the impacts of the primary alternative routes. The environmental consequences of this project are addressed

  18. Mathematical modeling of agricultural fires beneath high voltage transmission lines

    International Nuclear Information System (INIS)

    El-Zohri, Emad H.; Shafey, Hamdy M.; Abdel-Salam, M.; Ahmed, A.

    2011-01-01

    This paper presents a mathematical model for agricultural fires based on a multi-phase formulation. The model includes dehydration and pyrolysis of agricultural fuel and pyrolysis products. The model considers a homogeneous distribution of the agricultural solid fuel particles, interacting with the gas flow via source terms. These terms include: drag forces, production of water vapour and pyrolysis products, radiative and convective heat exchange. A multi-phase radiative transfer equation for absorbing-emitting medium is considered to account for the radiative heat exchange between the gas and solid phases of the fire. The main outputs of the present model are most important to study the influence of agricultural fire occurring beneath high voltage transmission lines. The agricultural fire causes a flashover due to the ambient temperature rise and soot accumulation on the insulator of these transmission lines. Numerical results of the present model are obtained for flat grassland fires to study the effects of wind velocity, solid fuel moisture content and ignition length on some selected fire outputs. These outputs include the temperature, velocity, soot volume fraction fields of the gas phase, together with fire propagation rate and flame geometry. The numerical results are compared to the available experimental work in the literature. -- Research highlights: → The model is sensitive to the initial condition of the ignition length affecting the fire propagation rate and width. → The model predicts the effects of both the wind velocity and the fuel moisture content on fire propagation rate, in agreement with the available experimental work in the literature. → The model shows that both the wind velocity and the fuel moisture content are important factors affecting the fire plume thickness, location, and inclination. → The model is able to visualize the flame geometry through tracing radiative heat rates exceeding a threshold value for flame visibility (60 k

  19. Broad line and pulsed NMR study of molecular motion in furfuryl alcohol resins

    International Nuclear Information System (INIS)

    Glowinkowski, S.; Pajak, Z.

    1978-01-01

    Broad line and pulsed nuclear magnetic resonance studies are carried out on a number of furfuryl alcohol resins differentiated by viscosity. Proton NMR spectra and relaxation times T 1 and Tsub(1rho) are measured over a wide temperature range and the results are interpreted in terms of molecular motion. The marked decrease in second moment and existence of high temperature spin-lattice relaxation times minima are presumed to result from rotational motion of polymer chains. The relaxation processes at low temperature are believed to be due to rotational motion of methyl endgroup and paramagnetic centres. (author)

  20. Full-wave analysis using a tangential vector finite-element formulation of arbitrary cross-section transmission lines for millimeter and microwave applications

    Science.gov (United States)

    Helal, M.; Legier, J. F.; Pribetich, P.; Kennis, P.

    1994-06-01

    A tangential vector finite-element formulation is implemented to deal with arbitrary cross section and metallic strip shape. Classical planar transmission lines as well as nonconventional cross-section waveguides such as the new microshield line are treated. Effects on propagation characteristics for these lines are studied when the metallization shape is approximated by a lossy trapezoid area.