WorldWideScience

Sample records for transitory endolymph leakage

  1. Transitory endolymph leakage induced hearing loss and tinnitus: depolarization, biphasic shortening and loss of electromotility of outer hair cells

    Science.gov (United States)

    Zenner, H. P.; Reuter, G.; Zimmermann, U.; Gitter, A. H.; Fermin, C.; LePage, E. L.

    1994-01-01

    There are types of deafness and tinnitus in which ruptures or massive changes in the ionic permeability of the membranes lining the endolymphatic space [e.g., of the reticular lamina (RL)] are believed to allow potassium-rich endolymph to deluge the low [K+] perilymphatic fluid (e.g., in the small spaces of Nuel). This would result in a K+ intoxication of sensory and neural structures. Acute attacks of Meniere's disease have been suggested to be an important example for this event. The present study investigated the effects of transiently elevated [K+] due to the addition of artificial endolymph to the basolateral cell surface of outer hair cells (OHC) in replicating endolymph-induced K+ intoxication of the perilymph in the small spaces of Nuel. The influence of K+ intoxication of the basolateral OHC cell surface on the transduction was then examined. Intoxication resulted in an inhibition of the physiological repolarizing K+ efflux from hair cells. This induced unwanted depolarizations of the hair cells, interfering with mechanoelectrical transduction. A pathological longitudinal OHC shortening was also found, with subsequent compression of the organ of Corti possibly influencing the micromechanics of the mechanically active OHC. Both micromechanical and electrophysiological alterations are proposed to contribute to endolymph leakage induced attacks of deafness and possibly also to tinnitus. Moreover, repeated or long-lasting K+ intoxications of OHC resulted in a chronic and complete loss of OHC motility. This is suggested to be a pathophysiological basis in some patients with chronic hearing loss resulting from Meniere's syndrome.

  2. Corporate Policies with Permanent and Transitory Shocks

    NARCIS (Netherlands)

    J-P. Decamps (Jean-Paul); S. Gryglewicz (Sebastian); E. Morellec (Erwan); S. Villeneuve (Stephane)

    2016-01-01

    textabstractWe model the financing, cash holdings, and hedging policies of a firm facing financing frictions and subject to permanent and transitory cash flow shocks. We show that permanent and transitory shocks generate distinct, sometimes opposite, effects on corporate policies and use the model

  3. Transition problems and play as transitory activity

    DEFF Research Database (Denmark)

    Broström, Stig

    2005-01-01

    Because too many children experience the transition to school as a culture shock, during the past decade teachers have implemented so-called transition activities in order to bridge the gap betwen pre-school and schoo. However, transition to school also calls for a development of higher mental...... functions, among others the development of children's learning motive. From the view of activity theori, transition to formal education entails crossing boundaries from the activity system play to the activity system of school learning. The transition can be facilitated by developing a 'transitory activity...... system', which mediates between the two systems, ensuring that the result of one system serves as a tool for the next. Advanced forms of play might make up a transitory activity system. The paper describes different forms of play crossing the boundaies of role play (frame-play, aesthetic theme play...

  4. The Density Difference of Cupula and Endolymph Changes the Mechanics of Semicircular Canals

    Science.gov (United States)

    Kondrachuk, Alexander V.; Boyle, Richard D.

    2011-11-01

    A precise balance of cupula and endolymph densities is key to the proper sensing of angular acceleration by the semicircular canals (SC). Estimates show that a density difference of cupula and endolymph (DD) as small as 10 - 4 g/cm3 is sufficient to make the SC sensitive to gravity and centrifugal forces provided they are comparable with gravity. As a result this might cause vestibular disorders. There are conditions under which the DD may even exceed this value. One of them is a change of intra-labyrinth pressure (IP) that may take place during a spaceflight. Here, the effect of DD on SC dynamics is considered using a simplified one-dimensional toroidal mathematical model of a canal for rotation with constant or harmonically oscillating angular velocities. The DD results in: dependence of cupula dynamics on orientation of both the gravity vector relative to the SC plane and the axis of rotation, as well as on the distance between the axis of rotation and the center of SC; shift of the cupula to a new position of equilibrium that depends on both the gravity vector and the parameters of head rotation; and onset of cupula oscillations with multiple frequencies under harmonic stimulation. The DD effect may be important under conditions of artificial gravity where the directions of centrifugal forces, the values of which are comparable with Earth's gravity, the orientations of the axis of rotation of a space station, and the axes of the SCs change during movements of the individuals and their habitat.

  5. Study of transitory forms of carotenoids

    International Nuclear Information System (INIS)

    Mathis, Paul

    1970-01-01

    In order to explain the biological role of the carotenoids their transitory forms were studied with an apparatus measuring the small (∼10 -3 ) short-lived (100 ns to 1 ms) optical density variations obtained by excitation with a ruby laser. Two forms were studied: a) Triplet state 3 Car. - This state (t 1/2 ∼6 μs) is obtained not by direct excitation but by T-T energy transfer from chlorophyll, in different media (chloroplasts, pigments in solution or in micelle). Two arguments can be advanced to explain in terms of triplet energy transfer an essential biological role of carotenoids, protection against photodynamic effects: - the energy level of 3 Car is lower than that of the singlet of oxygen; - in vivo the T-T transfer from chlorophyll to the carotenoids is very fast: 30 ns.. b) Radical cation Car + . - This form is obtained by electron transfer from carotene to the triplet of Toluidine Blue, in ethanol. Car + (t 1/2 ∼200 μs) shows a strong absorption band at 910 nm. The properties of Car + are discussed in relation to other polyene derivatives and to hydrocarbon ions. Car + could be involved in certain biological electron transfers. (author) [fr

  6. Getting the parking right for transit-oriented development.

    Science.gov (United States)

    2012-03-01

    Increasingly MPOs in Texas are incorporating Transit-Oriented Development (TOD) or similar : concepts into their long-range plans for the purpose of achieving sustainable transportation. : One major challenge to implementing these TOD-type strategies...

  7. Lumbricidae as transitory hosts in Metastrongylus infection in swine

    Directory of Open Access Journals (Sweden)

    Pavlović Ivan

    2005-01-01

    Full Text Available Metastrongylidosis or lungworm disease in swine is a disease caused by several types of nematodes of the genus Metastrongylus. Metastrongylidae are biohelminths whose causes use transitory hosts for their development and maintaining their biological cycle, and in this case they are numerous species of Lumbricidae (earthworms. Depending on the geographic environment, numerous representatives of Lumbricidae persist as transitory hosts. In our environment, these are dominant earthworm species of the genus Eisenia spp, Dandreobena spp, Allopbophora spp, Lubricus spp, Octoiasium spp, Bimastus spp, and rarely those from the genus Heledrillus spp. Swine are infected perorally with Metastrongylidae when they ingest infected earthworms.

  8. On Probability Leakage

    OpenAIRE

    Briggs, William M.

    2012-01-01

    The probability leakage of model M with respect to evidence E is defined. Probability leakage is a kind of model error. It occurs when M implies that events $y$, which are impossible given E, have positive probability. Leakage does not imply model falsification. Models with probability leakage cannot be calibrated empirically. Regression models, which are ubiquitous in statistical practice, often evince probability leakage.

  9. Transitory Control of Unsteady Separation using Pulsed Actuation

    International Nuclear Information System (INIS)

    Woo, George T K; Glezer, Ari

    2011-01-01

    The dynamic mechanisms of transitory flow attachment effected by pulsed actuation of the separated flow over a stalled airfoil are investigated experimentally. Actuation is effected by momentary pulsed jets generated by a spanwise array of combustion-based actuators such that the characteristic time of jet duration is nominally an order of magnitude shorter than the flow's convective time scale. The transitory flow field in the cross stream plane above the airfoil and in its near wake is investigated using multiple high-resolution PIV images that are obtained phase-locked to the actuation for continuous tracking of vorticity concentrations. The brief actuation pulse leads to severing of the separated vorticity layer and the subsequent shedding of large-scale vortical structures owing to the collapse of the separated flow domain which is accompanied by strong changes in the circulation about the entire airfoil. By exploiting the disparity between the characteristic times of flow response to actuation and relaxation, it is shown that successive actuation pulses can extend the flow attachment and enhance the global aerodynamic performance. It is also shown that coupling of the actuation to the airfoil's motion during cyclical pitch enhances the effect of transitory flow control and leads to a significant suppression of dynamic stall.

  10. Permanent and transitory oil volatility and aggregate investment in Malaysia

    International Nuclear Information System (INIS)

    Ibrahim, Mansor H.; Ahmed, Huson Joher Ali

    2014-01-01

    This paper investigates the relation between aggregate investment and oil volatility and its permanent and transitory components for a developing country, Malaysia. In the paper, the components generalized autoregressive conditional heteroskedasticity (CGARCH) model is utilized to decompose conditional oil volatility into permanent oil volatility and transitory oil volatility. Respectively reflecting fundamental-driven and random shifts in oil volatility, they are expected to exert differential effects on aggregate investment. Adopting a vector autoregression (VAR) framework to allow feedback effects between aggregate investment and its determinants, the paper documents evidence supporting the adverse effects of conditional oil volatility, permanent oil volatility and transitory oil volatility on aggregate investment and real output. Interestingly, contrary to the findings for the developed markets (US and OECD), the real effects of permanent oil volatility tend to be stronger. These findings are reasonably robust to variable specification and measurements in the VAR system. Hence, there is an indication that heightened oil volatility accounts for the slumps in Malaysia's aggregate investment after the Asian financial crisis. - Highlights: • Examines the role of oil volatility in Malaysia's aggregate investment. • Makes distinction between permanent and temporary volatility using CGARCH. • Both volatility components depress investment. • Permanent volatility has larger adverse effects. • Results are robust to alternative model specifications

  11. The duration of the transitory period of public gas distribution

    International Nuclear Information System (INIS)

    Gazzola, D.

    2006-01-01

    The article describes the interpretative problems concerning the duration of the transitory period of public gas distribution after law decree 273/05 came into effect. This decree is the third legislative measure which, in a period of five years, reforms the transitory provisions. The article outlines the normative background of legislative decree n. 164/00 (so called Letta decree) and law n. 239/04 (so called Marzano law) and it analyses their judicial interpretations. It then explains the changes introduced by law decree n. 273/05 and the new interpretative problems there might be with reference to this decree. The decree clarifies the due date of the transitory period and specifies that the date of 31st December 2005 is postponed to 31st December 2007. The Administrative Tribunal of Lombardia Region Brescia tried to limit the effects of law decree n. 273/05, stating that the new expiration date could not regard the contracts for which the local authorities had already acknowledged the previous due date. The State Council argued instead that the new law decree regards all the contracts. This decree also clarifies that the chances of increasing duration ex art. 15, comma 7, legislative decree n. 164/00, applies automatically, but it doesn't solve the interpretative problem concerning the possibility of adding up more than one of these chances. The article focuses on the problems of the public gas distribution after the reform of this sector with the implementation of directive n. 98/30/CE and it underlines that the various legislative measures of these years are indicative of the difficulty to allow a gradual transition towards a liberalized market. In this context, law decree n. 273/05 is the last legislative measure which tries to guarantee a balance between the rapid liberalization of the market, on one hand, and the interests of the firms which had contracts when the reform came into effect, on the other hand [it

  12. Attention-level transitory response: a novel hybrid BCI approach

    Science.gov (United States)

    Diez, Pablo F.; Garcés Correa, Agustina; Orosco, Lorena; Laciar, Eric; Mut, Vicente

    2015-10-01

    Objective. People with disabilities may control devices such as a computer or a wheelchair by means of a brain-computer interface (BCI). BCI based on steady-state visual evoked potentials (SSVEP) requires visual stimulation of the user. However, this SSVEP-based BCI suffers from the ‘Midas touch effect’, i.e., the BCI can detect an SSVEP even when the user is not gazing at the stimulus. Then, these incorrect detections deteriorate the performance of the system, especially in asynchronous BCI because ongoing EEG is classified. In this paper, a novel transitory response of the attention-level of the user is reported. It was used to develop a hybrid BCI (hBCI). Approach. Three methods are proposed to detect the attention-level of the user. They are based on the alpha rhythm and theta/beta rate. The proposed hBCI scheme is presented along with these methods. Hence, the hBCI sends a command only when the user is at a high-level of attention, or in other words, when the user is really focused on the task being performed. The hBCI was tested over two different EEG datasets. Main results. The performance of the hybrid approach is superior to the standard one. Improvements of 20% in accuracy and 10 bits min-1 are reported. Moreover, the attention-level is extracted from the same EEG channels used in SSVEP detection and this way, no extra hardware is needed. Significance. A transitory response of EEG signal is used to develop the attention-SSVEP hBCI which is capable of reducing the Midas touch effect.

  13. Land-use Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  14. Data leakage quantification

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.; Atluri, V.; Pernul, G.

    2014-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. These solutions often produce a large number of alerts, whose

  15. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  16. ATR confinement leakage determination

    International Nuclear Information System (INIS)

    Kuan, P.; Buescher, B.J.

    1998-01-01

    The air leakage rate from the Advanced Test Reactor (ATR) confinement is an important parameter in estimating hypothesized accidental releases of radiation to the environment. The leakage rate must be determined periodically to assure that the confinement has not degraded with time and such determination is one of the technical safety requirements of ATR operation. This paper reviews the methods of confinement leakage determination and presents an analysis of leakage determination under windy conditions, which can complicate the interpretation of the determined leakage rates. The paper also presents results of analyses of building air exchange under windy conditions. High wind can enhance air exchange and this could increase the release rates of radioisotopes following an accident

  17. Radioactivity leakage monitoring system

    International Nuclear Information System (INIS)

    Nakajima, Takuichiro; Noguchi, Noboru.

    1982-01-01

    Purpose: To obtain a device for detecting the leakage ratio of a primary coolant by utilizing the variation in the radioactivity concentration in a reactor container when the coolant is leaked. Constitution: A measurement signal is produced from a radioactivity measuring instrument, and is continuously input to a malfunction discriminator. The discriminator inputs a measurement signal to a concentration variation discriminator when the malfunction is recognized and simultaneously inputs a measurement starting time from the inputting time to a concentration measuring instrument. On the other hand, reactor water radioactivity concentration data obtained by sampling the primary coolant is input to a concentration variation computing device. A comparator obtains the ratio of the measurement signal from the measuring instrument and the computed data signal from the computing device at the same time and hence the leakage rate, indicates the average leakage rate by averaging the leakage rate signals and also indicates the total leakage amount. (Yoshihara, H.)

  18. Model for Electromagnetic Information Leakage

    OpenAIRE

    Mao Jian; Li Yongmei; Zhang Jiemin; Liu Jinming

    2013-01-01

    Electromagnetic leakage will happen in working information equipments; it could lead to information leakage. In order to discover the nature of information in electromagnetic leakage, this paper combined electromagnetic theory with information theory as an innovative research method. It outlines a systematic model of electromagnetic information leakage, which theoretically describes the process of information leakage, intercept and reproduction based on electromagnetic radiation, and ana...

  19. Predator transitory spillover induces trophic cascades in ecological sinks

    DEFF Research Database (Denmark)

    Casini, Michele; Blenckner, Thorsten; Möllmann, Christian

    2012-01-01

    Understanding the effects of cross-system fluxes is fundamental in ecosystem ecology and biological conservation. Source-sink dynamics and spillover processes may link adjacent ecosystems by movement of organisms across system boundaries. However, effects of temporal variability in these cross-sy...... in structuring natural systems. The integration of regional and local processes is central to predict species and ecosystem responses to future climate changes and ongoing anthropogenic disturbances......Understanding the effects of cross-system fluxes is fundamental in ecosystem ecology and biological conservation. Source-sink dynamics and spillover processes may link adjacent ecosystems by movement of organisms across system boundaries. However, effects of temporal variability in these cross......-system fluxes on a whole marine ecosystem structure have not yet been presented. Here we show, using 35 y of multitrophic data series from the Baltic Sea, that transitory spillover of the top-predator cod from its main distribution area produces cascading effects in the whole food web of an adjacent and semi...

  20. The impact of transit-oriented development on social capital : [brief].

    Science.gov (United States)

    2016-10-01

    Transit-oriented development (TOD), : the clustering of new, more intensive : development near transit stations, : has many advantages. While TODs : can lead to increased public transit use, some have argued that wider community benefits can : accrue...

  1. Moving toward implementation : an examination of the organizational and political structures of transit-oriented development.

    Science.gov (United States)

    2009-06-01

    The research explores the costs and impacts of Transit Oriented Development (TOD) and : addresses the rationale for designing transit-oriented neighborhoods. It also documents the : outcomes and the impacts of implementing such projects and examines ...

  2. Universal leakage elimination

    International Nuclear Information System (INIS)

    Byrd, Mark S.; Lidar, Daniel A.; Wu, L.-A.; Zanardi, Paolo

    2005-01-01

    'Leakage' errors are particularly serious errors which couple states within a code subspace to states outside of that subspace, thus destroying the error protection benefit afforded by an encoded state. We generalize an earlier method for producing leakage elimination decoupling operations and examine the effects of the leakage eliminating operations on decoherence-free or noiseless subsystems which encode one logical, or protected qubit into three or four qubits. We find that by eliminating a large class of leakage errors, under some circumstances, we can create the conditions for a decoherence-free evolution. In other cases we identify a combined decoherence-free and quantum error correcting code which could eliminate errors in solid-state qubits with anisotropic exchange interaction Hamiltonians and enable universal quantum computing with only these interactions

  3. The Role of Permanent and Transitory Components in Business Cycle Volatility Moderation

    OpenAIRE

    Korenok, Oleg; Radchenko, Stanislav

    2004-01-01

    The paper examines the processes underlying economic fluctuations by investigating the volatility moderation of U.S. economy in the early 1980's. We decompose the volatility decline using a dynamic factor framework into a common stochastic trend, common transitory component and idiosyncratic components. We find that the moderation of business cycle was a result of the moderation in transitory and idiosyncratic components. Our results suggest that important part of stochastic process that driv...

  4. Trace element-protein interactions in endolymph from the inner ear of fish: implications for environmental reconstructions using fish otolith chemistry.

    Science.gov (United States)

    Thomas, Oliver R B; Ganio, Katherine; Roberts, Blaine R; Swearer, Stephen E

    2017-03-22

    Otoliths, the biomineralised hearing "ear stones" from the inner ear of fish, grow throughout the lifespan of an individual, with deposition of alternating calciferous and proteinaceous bands occurring daily. Trace element : calcium ratios within daily increments measured by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) are often used in fisheries science to reconstruct environmental histories. There is, however, considerable uncertainty as to which elements are interacting with either the proteinaceous or calciferous zones of the otolith, and thus their utility as indicators of environmental change. To answer this, we used size exclusion chromatography-inductively coupled plasma-mass spectrometry (SEC-ICP-MS) of endolymph, the otolith growth medium, to determine the binding interactions for a range of elements. In addition, we used solution ICP-MS to quantify element concentrations in paired otolith and endolymph samples and determined relative enrichment factors for each. We found 12 elements that are present only in the proteinaceous fraction, 6 that are present only in the salt fraction, and 4 that are present in both. These findings have important implications for the reconstruction of environmental histories based on changes in otolith elemental composition: (1) elements occurring only in the salt fraction are most likely to reflect changes in the physico-chemical environment experienced during life; (2) elements occurring only in the proteinaceous fraction are more likely to reflect physiological rather than environmental events; and (3) elements occurring in both the salt and proteinaceous fractions are likely to be informative about both endogenous and exogenous processes, potentially reducing their utility in environmental reconstructions.

  5. Coolant leakage detecting device

    International Nuclear Information System (INIS)

    Yamauchi, Kiyoshi; Kawai, Katsunori; Ishihara, Yoshinao.

    1995-01-01

    The device of the present invention judges an amount of leakage of primary coolants of a PWR power plant at high speed. Namely, a mass of coolants contained in a pressurizer, a volume controlling tank and loop regions is obtained based on a preset relational formula and signals of each of process amount, summed up to determine the total mass of coolants for every period of time. The amount of leakage for every period of time is calculated by a formula of Karman's filter based on the total mass of the primary coolants for every predetermined period of time, and displays it on CRT. The Karman's filter is formed on every formula for several kinds of states formed based on the preset amount of the leakage, to calculate forecasting values for every mass of coolants. An adaptable probability for every preset leakage amount is determined based on the difference between the forecast value and the observed value and the scattering thereof. The adaptable probability is compared with a predetermined threshold value, which is displayed on the CRT. This device enables earlier detection of leakage and identification of minute leakage amount as compared with the prior device. (I.S.)

  6. Coolant leakage detection device

    International Nuclear Information System (INIS)

    Ito, Takao.

    1983-01-01

    Purpose: To surely detect the coolant leakage at a time when the leakage amount is still low in the intra-reactor inlet pipeway of FBR type reactor. Constitution: Outside of the intra-reactor inlet piping for introducing coolants at low temperature into a reactor core, an outer closure pipe is furnished. The upper end of the outer closure pipe opens above the liquid level of the coolants in the reactor, and a thermocouple is inserted to the opening of the upper end. In such a structure, if the coolants in the in-reactor piping should leak to the outer closure pipe, coolants over-flows from the opening thereof, at which the thermocouple detects the temperature of the coolants at a low temperature, thereby enabling to detect the leakage of the coolants at a time when it is still low. (Kamimura, M.)

  7. Channel follower leakage restrictor

    International Nuclear Information System (INIS)

    Williamson, H.E.; Smith, B.A.

    1977-01-01

    An improved means is provided to control coolant leakage between the flow channel and the lower tie plate of a nuclear fuel assembly. The means includes an opening in the lower tie plate and a movable element adjacent thereto. The coolant pressure within the tie plate biases the movable means toward the inner surface of the surrounding flow channel to compensate for any movement of the flow channel away from the lower tie plate to thereby control the leakage of coolant flow from the fuel assemblies to the spaces among the fuel assemblies of the core. 9 figures

  8. Assessing Agulhas leakage

    NARCIS (Netherlands)

    van Sebille, E.

    2009-01-01

    Agulhas leakage, the water that flows from the Indian Ocean to the Atlantic Ocean, plays an important role in the circulation of the Atlantic Ocean. The magnitude of this flux of warm and saline Indian Ocean water into the much colder and fresher Atlantic Ocean can be related to the strength of the

  9. Roxby Downs water leakage

    International Nuclear Information System (INIS)

    1996-01-01

    The Environment, Resource and development Committee has been asked by Parliament to examine 'a massive leakage of water at Roxby Downs' and to make recommendations 'as to further action'. It has also been specifically asked to comment on 'the desirability of the Department of Mines and Energy having prime responsibility for environmental matters in relation to mining operations'. This report begins with a description of the Olympic Dam operations near Roxby Downs and with a brief overview of the regulations controlling those operations. The site of the leakage the Olympic Dam tailings retention system is then described in greater detail. Part 3 describes how the system was originally designed, modified and approved. It ends with a series of findings about the adequacy of the original design (including the monitoring systems built into it) and of the approvals process. Recommendations are then made about how future approvals should be handled. Part 4 of the report outlines how the tailings retention system was built and operated and how the massive leakage from it was detected and reported. Findings about the adequacy of the management of the system and about the initial reactions to the leakage are then made, together with recommendations designed to improve future management of the system. 25 refs., 15 figs

  10. Colorectal Anastomotic Leakage: New perspectives

    NARCIS (Netherlands)

    F. Daams (Freek)

    2014-01-01

    markdownabstract__Abstract__ This thesis provides new perspectives on colorectal anastomotic leakages. In both experimental and clinical studies, aspects of prevention, early identification, treatment and consequences of anastomotic leakage are discussed.

  11. 77 FR 21098 - Notice of Meeting of the Environmental Financial Advisory Board (EFAB), and Transit-Oriented...

    Science.gov (United States)

    2012-04-09

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9656-6] Notice of Meeting of the Environmental Financial... Financial Advisory Board (EFAB) will hold a meeting on May 22-23, 2012 and a Transit-Oriented Development... discussed include: clean air technology; tribal environmental programs; transit-oriented development; energy...

  12. The common-trend and transitory dynamics in real exchange rate fluctuations

    DEFF Research Database (Denmark)

    Bergman, Ulf Michael; Cheung, Yin-Wong; Lai, Kon S.

    2011-01-01

    estimate can be sensitive to whether or not long-run Purchasing Power Parity (PPP) is imposed on the data. Further analysis suggests that both CT and transitory innovations are linked much more to interest rate changes than to productivity changes. Accordingly, it is interest rate, not productivity...

  13. The role of incentives in implementing successful transit-oriented development strategies

    NARCIS (Netherlands)

    Tan, W.G.Z.; Janssen-Jansen, L.B.; Bertolini, L.

    2014-01-01

    The pursuit of transit-oriented development strategies (TODS) is a worldwide phenomenon but knowledge of the process of implementation remains approximate. The ingredients for changing from a non-conducive to a conducive environment for TODS and how that change occurs remain unclear. In cases of

  14. The Role of Incentives in Implementing Successful Transit-Oriented Development Strategies

    NARCIS (Netherlands)

    Tan, Wendy G.Z.; Janssen-jansen, Leonie B.; Bertolini, Luca

    2014-01-01

    The pursuit of transit-oriented development strategies (TODS) is a worldwide phenomenon but knowledge of the process of implementation remains approximate. The ingredients for changing from a non-conducive to a conducive environment for TODS and how that change occurs remain unclear. In cases of

  15. The role of institutional innovation and learning when pursuing transit-oriented development strategies : EURA 2013

    NARCIS (Netherlands)

    Tan, Wendy

    2013-01-01

    Transit-oriented development strategies (TODS) are widely pursued by planners and policy makers. However, there is a lack of0clarity on how institutional innovation and learning accompanying0institutional change0facilitates an explicit shift towards a conducive context for TODS. This is evident in

  16. Leakage radiation interference microscopy.

    Science.gov (United States)

    Descrovi, Emiliano; Barakat, Elsie; Angelini, Angelo; Munzert, Peter; De Leo, Natascia; Boarino, Luca; Giorgis, Fabrizio; Herzig, Hans Peter

    2013-09-01

    We present a proof of principle for a new imaging technique combining leakage radiation microscopy with high-resolution interference microscopy. By using oil immersion optics it is demonstrated that amplitude and phase can be retrieved from optical fields, which are evanescent in air. This technique is illustratively applied for mapping a surface mode propagating onto a planar dielectric multilayer on a thin glass substrate. The surface mode propagation constant estimated after Fourier transformation of the measured complex field is well matched with an independent measurement based on back focal plane imaging.

  17. Leakage resilient password systems

    CERN Document Server

    Li, Yingjiu; Deng, Robert H

    2015-01-01

    This book investigates tradeoff between security and usability in designing leakage resilient password systems (LRP) and introduces two practical LRP systems named Cover Pad and ShadowKey. It demonstrates that existing LRP systems are subject to both brute force attacks and statistical attacks and that these attacks cannot be effectively mitigated without sacrificing the usability of LRP systems. Quantitative analysis proves that a secure LRP system in practical settings imposes a considerable amount of cognitive workload unless certain secure channels are involved. The book introduces a secur

  18. Understanding the importance of permanent and transitory shocks at business cycle horizons for the UK

    Science.gov (United States)

    Narayan, Paresh Kumar

    2008-05-01

    The goal of this paper is to examine the relative importance of permanent and transitory shocks in explaining variations in macroeconomic aggregates for the UK at business cycle horizons. Using the common trend-common cycle restrictions, we estimate a variance decomposition of shocks, and find that over short horizons the bulk of the variations in income and consumption were due to permanent shocks while transitory shocks explain the bulk of the variations in investment. Our findings for income and consumption are consistent with real business cycle models which emphasize the role of aggregate supply shocks, while our findings for investment are consistent with the Keynesian school of thought, which emphasizes the role of aggregate demand shocks in explaining business cycles.

  19. Predicting bulk powder flow dynamics in a continuous mixer operating in transitory regimes

    OpenAIRE

    Ammarcha , Chawki; Gatumel , Cendrine; Dirion , Jean-Louis; Cabassud , Michel; Mizonov , Vadim; Berthiaux , Henri

    2012-01-01

    International audience; Over recent years there has been increasing interest in continuous powder mixing processes, due mainly to the development of on-line measurement techniques. However, our understanding of these processes remains limited, particularly with regard to their flow and mixing dynamics. In the present work, we study the behaviour of a pilot-scale continuous mixer during transitory regimes, in terms of hold-up weight and outflow changes. We present and discuss experimental resu...

  20. Transit-Oriented Development and Ports: National Analysis across the United States and a Case Study of New Orleans

    Science.gov (United States)

    2017-11-01

    The aim of this study is to examine the extent that freight and passenger transportation planning overlap within the context of transit-oriented developments (TODs) near ports. This study also includes a case study of New Orleans. Research questions ...

  1. Leakage monitoring device and method

    International Nuclear Information System (INIS)

    Yamada, Izumi; Matsui, Yuji; Fujimori, Haruo.

    1995-01-01

    In a water leakage monitor for a steam generator, output signals from an acoustic sensor disposed in the vicinity of a region to be monitored is subjected to phasing calculation (beam forming calculation) to determine the distribution of a sound source intensity distribution. A peak is retrieved based on the distribution of the sound source intensity distribution. A correction coefficient depending on the position of the peak is multiplied to the sound source intensity. The presence or absence of leakage is determined based on the degree of the sound source intensity after the completion of correction. Namely, a relative value of sound source intensity for each of the portions in the region to be monitored is determined, and the point of the greatest sound source intensity is assumed as a leaking point, to determine the position of the leakage. An absolute value of the sound source intensity at the leaking point is determined by such a constitution that a correction coefficient depending on the position is multiplied to the intensity of the position of the peak in the distribution of the sound intensity. A threshold value for the determination of the presence or absence of the leakage can be set if a relation between an amount of the leakage previously determined experimentally and the intensity of the sound source. Then, a countermeasure can easily be taken after the detection of the leakage and a restoring operation can be carried out rapidly after the occurrence of leakage while avoiding unnecessary shutdown. (N.H.)

  2. Inner volume leakage during integrated leakage rate testing

    International Nuclear Information System (INIS)

    Glover, J.P.

    1987-01-01

    During an integrated leak rate test (ILRT), the containment structure is maintained at test pressure with most penetrations isolated. Since penetrations typically employ dual isolation, the possibility exists for the inner isolation to leak while the outer holds. In this case, the ILRT instrumentation system would indicate containment out-leakage when, in fact, only the inner volume between closures is being pressurized. The problem is compounded because this false leakage is not readily observable outside of containment by standard leak inspection techniques. The inner volume leakage eventually subsides after the affected volumes reach test pressure. Depending on the magnitude of leakage and the size of the volumes, equalization could occur prior to the end of the pretest stabilization period, or significant false leakages may persist throughout the entire test. Two simple analyses were performed to quantify the effects of inside volume leakages. First, a lower bound for the equalization time was found. A second analysis was performed to find an approximate upper bound for the stabilization time. The results of both analyses are shown

  3. [Use of fibrin glue in the prevention of leakage in pancreatico-jejunal anastomoses].

    Science.gov (United States)

    Stojanović, M; Jeremic, M; Stojanović, P; Stojiljković, M; Gmijović, D; Stanojković, Z; Savić, V; Djordjević, V; Cvetković, Z; Kostov, M; Colović, R

    2002-01-01

    The aim of this study was to test the protective effects of fibrin sealing on the pancreatico-jejunostomy (PJA), the high-risk anastomosis following pancreas head resection. Experimental study was performed on the mongrel dogs, divided in two groups (20 animals each): Experimental group-with end to end "dunking" PJA, protected by temporary occlusion of the pancreatic duct with fibrin sealant/Tissucol/Immuno Ag/, while control group was without any protective procedure. The animals were followed 5 months in order to study: protective effects of such procedure on the PJA quantified with the percent of anastomotic leakage, effects of the exocrine secretion and effects the endocrine function Results: PJA leakage occurred in 13.33% in control group. No leakage was registered in experimental group. Biochemical, histological and electron microscopic study showed slight transitory elevation of amylase levels. Fibrin glue plug was dissolved and pancreatic juice output was reestablished 12th days postoperatively. Long term follow-up showed no damages of the endocrine and exocrine pancreas. Pancreatic duct occlusion with fibrin glue appeared to be an useful method in the prevention of pancreatico-jejunostomy leakage, without negative effects on the exocrine and endocrine pancreas.

  4. The transitory and permanent volatility of oil prices: What implications are there for the US industrial production?

    International Nuclear Information System (INIS)

    Ali Ahmed, Huson Joher; Bashar, Omar H.M.N.; Wadud, I.K.M. Mokhtarul

    2012-01-01

    Highlights: ► This study examines the impact of oil price uncertainty on the US industrial production (IPI). ► The transitory component of the oil price volatility has an adverse impact on the US IPI. ► The transitory oil price volatility induces higher volatility in CPI, commodity prices and IPI. -- Abstract: This study examines the impact of oil price uncertainty on the US industrial production by decomposing oil price volatility into permanent and transitory components. The decompositions provide important evidence on sources and asymmetric effects of oil price volatility. To estimate the component structure of volatility and to analyse the dynamic impacts of the volatility components, the study uses a threshold based CGARCH and VAR modelling over a period from 1980 to 2010 for the US economy. The CGARCH model estimates show significant asymmetric effect of oil price shock on the transitory oil price volatility. Dynamic impulse response functions obtained from the estimated VAR models reveal that there is a significant and prolonged dampening impact of increased transitory oil price volatility on industrial production. The results also suggest that shocks to transitory component induce increased volatility in the general price level and non-fuel commodity prices in the US. Variance decomposition analysis reconfirms that the transitory volatility is the second most important factor to explain the variance of industrial production. These results provide additional insights on the sources of oil price uncertainty and point to the need to direct US energy policies towards stabilising short-term uncertainties in oil prices.

  5. Transitory cell attachments in the differentiating glomerular epithelium of the opossum metanephros.

    Science.gov (United States)

    Krause, W J; Cutts, J H

    1980-01-01

    Numerous transitory intercellular attachments are observed between the central, lateral surfaces of adjacent glomerular epithelial cells in the differentiating renal corpuscle. The junctions are characterized by an increased electron density of the adjacent cell membranes and cytoplasm. The intervening intercellular space may contain an amorphous material of moderate electron density. The distribution and position of such temporary cell attachments, together with their modification and subsequent loss during the differentiation of podocytes, suggest that they play an important role in the histogenesis of the glomerular epithelium.

  6. Simulation of the fault transitory of the feedwater controller in a Boiling water reactor with the Ramona-3B code

    International Nuclear Information System (INIS)

    Hernandez M, J.L.; Ortiz V, J.

    2005-01-01

    The obtained results when carrying out the simulation of the fault transitory of the feedwater controller (FCAA) with the Ramona-3B code, happened in the Unit 2 of the Laguna Verde power plant (CNLV), in September of the year 2000 are presented. The transitory originates as consequence of the controller's fault of speed of a turbo pump of feedwater. The work includes a short description of the event, the suppositions considered for the simulation and the obtained results. Also, a discussion of the impact of the transitory event is presented on aspects of reactor safety. Although the carried out simulation is limited by the capacities of the code and for the lack of available information, it was found that even in a conservative situation, the power was incremented only in 12% above the nominal value, while that the thermal limit determined by the minimum reason of the critical power, MCPR, always stayed above the limit values of operation and safety. (Author)

  7. Containment leakage rate testing requirements

    International Nuclear Information System (INIS)

    Arndt, E.G.

    1992-01-01

    This report presents the status of several documents under revision or development that provide requirements and guidance for testing nuclear power plant containment systems for leakage rates. These documents include the general revision to 10 CFR Part 50, Appendix J; the regulatory guide affiliated with the revision to Appendix J; the national standard that the regulatory guide endorses, ANSI/ANS-56.8, 'Containment System Leakage Rate Testing Requirements'; and the draft industry Licensing Topical Report, 'Standardized Program for Primary Containment Integrity Testing'. The actual or potential relationships between these documents are also explored

  8. Practical Leakage-Resilient Symmetric Cryptography

    DEFF Research Database (Denmark)

    Faust, Sebastian; Pietrzak, Krzysztof; Schipper, Joachim

    2012-01-01

    Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount of arbitr......Leakage resilient cryptography attempts to incorporate side-channel leakage into the black-box security model and designs cryptographic schemes that are provably secure within it. Informally, a scheme is leakage-resilient if it remains secure even if an adversary learns a bounded amount...

  9. An Empirical Study on Transit-Oriented Low-Carbon Urban Land Use Planning

    DEFF Research Database (Denmark)

    Dou, Yi; Luo, Xiao; Dong, Liang

    2016-01-01

    Low-carbon urban development is a hot spot of global concerns for fighting against climate change for China, transportation sector has a significant contribution to urban CO2 emissions, while the emissions are still increasing. Transit-Oriented Development (TOD) strategies provide a novel approach...... for urban planners to facilitate the urban carbon mitigation from transportation sector in long-term. While TOD strategies are emerging cases, they are merely qualitatively discussed in China, lacking practical indicators and quantitative verification for supporting the real urban plan...... population and transportation accessibility with Geographic Weighted Regression model. Results highlight that TOD can effectively improve the transportation network with higher accessibility and lower urban carbon emissions. The outcomes of this study provide critical insights to the recent practice...

  10. Analysis of travel patterns between road and transit-oriented development areas

    International Nuclear Information System (INIS)

    Lee, S.; Park, D.; Lee, C.

    2010-01-01

    Rapid economic growth has caused severe traffic congestion and air pollution in the Seoul metropolitan area (SMA). As a consequence, traffic demand management (TDM) policies have been implemented to mitigate traffic congestion in the region. This study analyzed travel patterns that occurred as a result of transport policy changes in Seoul between 1996 and 2002. General travel pattern changes in the SMA were compared with the travel patterns of regions with car-oriented road construction policies and public transit-invested regions. Results of the study showed that investment in road construction had no significant impact on reducing traffic congestion. The modal shift to public transit modes caused a reduction in the number of cars on roads. The study demonstrated that transit-oriented policies can be used to overcome severe traffic congestion. 7 refs., 7 tabs., 6 figs.

  11. Transitory provisions on public gas distribution in the light of the Marzano law

    International Nuclear Information System (INIS)

    Vedaschi, Arianna

    2005-01-01

    The article begins by describing community law on public gas distribution service, then it examines legislative decree 164/2000( also called Letta Decree), which implements directive no. 98/30/CE. This directive reforms the gas sector and in particular it reforms the way gas is distributed. Art. 14 of the Letta Decree states that the distribution of natural gas shall be a public service, contractors shall be selected through a public tender and contracts shall be stipulate for a maximum of 12 years. Thus it is evident that the new model is radically different from the previous one. Before, the service was provided by the local authorities (either directly or through a long-term lease); now the new model aims at liberalizing the market by out sourcing gas distribution. Out sourcing is carried out through a public tender and for short periods of time. In order to allow a gradual transition from the old model to the new one, the Letta Decree provides for a transitory period articulated in various phases. This has the aim of guaranteeing a balance between the interest of local authorities, on one hand and the firms that distributed gas before the reform came into effect, on the other. The first part of the article focuses on interpretative problems that arose after law no. 239/2004 (so called Marzano law) was passed. In the second half it compares the different judicial interpretations concerning: a) duration of the transitory period; b) possibility of increasing duration as provided for by art. 15, par.7 of legislative decree 164/2000; c) efficacy of the abrogation of art. 15, par.8 of legislative decree 164/2000 and finally d) whether advanced redemption of the gas distribution service is still possible. With regards to the transitory period, the article compares judgement no. 111/2005 by the Administrative Tribunal of Lombardia, with judgement no. 6187/2005 delivered by the Sixth Section of the State Council. It then argues that the prohibition of concentration has

  12. Impacts of Transit-Oriented Compact-Growth on Air Pollutant Concentrations and Exposures in the Tampa Region

    Science.gov (United States)

    2018-03-31

    Amy L. Stuart (ORCID # 0000-0003-1229-493) The objective of this study was to model the potential impacts of alternative transit-oriented urban design scenarios on community exposures to roadway air pollution. We used a modeling framework developed p...

  13. Automation of unit for leakage test

    OpenAIRE

    LYCHKOVSKAYA V.S.; TSYGANKOV A.S.; GRINBERG G.M.; STANOVOVA O.A.

    2015-01-01

    Federal state educational standard requirements for training of university students have been considered. Leakage test procedures for components of aerospace vehicles have been described. Automation procedures of existing laboratory leakage test units have been outlined.

  14. Issues behind Competitiveness and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the vulnerability of heavy industry to carbon leakage and competitiveness loss. It reviews the existing literature on competitiveness and carbon leakage under uneven climate policies. It also suggests a statistical method to track carbon leakage, and applies this methodology to Phase I of the EU emissions trading scheme, for various industrial activities: iron and steel, cement, aluminium and refineries. Finally, it reviews measures to mitigate carbon leakage, as discussed in Australia, Canada, Europe, New Zealand and the US.

  15. Subsea Hydraulic Leakage Detection and Diagnosis

    OpenAIRE

    Stavenes, Thomas

    2010-01-01

    The motivation for this thesis is reduction of hydraulic emissions, minimizing of process emergency shutdowns, exploitation of intervention capacity, and reduction of costs. Today, monitoring of hydraulic leakages is scarce and the main way to detect leakage is the constant need for filling of hydraulic fluid to the Hydraulic Power Unit (HPU). Leakage detection and diagnosis has potential, which would be adressed in this thesis. A strategy towards leakage detection and diagnosis is given....

  16. Simulation of leakage through mechanical sealing device

    Science.gov (United States)

    Tikhomorov, V. P.; Gorlenko, O. A.; Izmerov, M. A.

    2018-03-01

    The procedure of mathematical modeling of leakage through the mechanical seal taking into account waviness and roughness is considered. The percolation process is represented as the sum of leakages through a gap between wavy surfaces and percolation through gaps formed by fractal roughness, i.e. the total leakage is determined by the slot model and filtration leakage. Dependences of leaks on the contact pressure of corrugated and rough surfaces of the mechanical seal elements are presented.

  17. Heat exchanger leakage problem location

    Directory of Open Access Journals (Sweden)

    Jícha Miroslav

    2012-04-01

    Full Text Available Recent compact heat exchangers are very often assembled from numerous parts joined together to separate heat transfer fluids and to form the required heat exchanger arrangement. Therefore, the leak tightness is very important property of the compact heat exchangers. Although, the compact heat exchangers have been produced for many years, there are still technological problems associated with manufacturing of the ideal connection between the individual parts, mainly encountered with special purpose heat exchangers, e.g. gas turbine recuperators. This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine recuperator. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.

  18. Integrating Regret Psychology to Travel Mode Choice for a Transit-Oriented Evacuation Strategy

    Directory of Open Access Journals (Sweden)

    Shi An

    2015-06-01

    Full Text Available Facing the potential dangers from sudden disasters in urban cities, emergency administrators have to make an appropriate evacuation plan to mitigate negative consequences. However, little attention has been paid to evacuee real decision psychology when developing a strategy. The aim of this paper is to analyze evacuee mode choice behavior considering regret aversion psychology during evacuation. First, the utility-based and regret-based models are formulated to obtain evacuees’ preferences on travel mode choice, respectively. According to the data collected from the stated preference (SP survey on evacuee mode choice, the estimation results show that the regret-based model performs better than the utility model. Moreover, based on the estimates from behavioral analysis, the elasticities of evacuee mode choices are calculated, and transit strategy simulation is undertaken to investigate the influence on evacuee mode switching from private automobile to public transit. The results are expected to help emergency administrators to make a transit-oriented strategy for a sustainable evacuation plan, especially for the benefit of carless people.

  19. Model for the analysis of transitories and stability of a BWR reactor with fuel of thorium

    International Nuclear Information System (INIS)

    Nunez C, A.; Espinosa P, G.; Francois L, J.L.

    2004-01-01

    In this work it is described the thermo hydraulic and neutronic pattern used to simulate the behavior of a nucleus of thorium-uranium under different conditions of operation. The analysed nucleus was designed with base to assemblies that operate under the cover-seed concept. The pattern was proven to conditions of stationary state and transitory state. Here it is only presented the simulation of the one SCRAM manual and it is compared in the behavior of a nucleus with UO 2 . Additionally one carries out an analysis of stability taking into account the four corners that define the area of stability of the map flow-power and to conditions of 100% of flow and 100% of power. The module of stability is based on the pattern of Lahey and Podowsky to estimate the drops of pressure during a perturbation. It is concludes that the behavior of this nucleus is not very different to the one shown by the nuclei loaded with the fuel of UO 2 . (Author)

  20. A Study of the Planning and Designing of the Built Environment under the Green Transit-Oriented Development

    OpenAIRE

    Wann-Ming Wey

    2016-01-01

    In recent years, the problems of global climate change and natural disasters have induced the concerns and attentions of environmental sustainability issues for the public. Aside from the environmental planning efforts done for human environment, Transit-Oriented Development (TOD) has been widely used as one of the future solutions for the sustainable city development. In order to be more consistent with the urban sustainable development, the development of the built environment planning base...

  1. Why the CDM can reduce carbon leakage

    International Nuclear Information System (INIS)

    Kallbekken, S.

    2006-04-01

    Carbon leakage is an important concern because it can reduce the environmental effectiveness of the Kyoto Protocol. The Clean Development Mechanism, one of the flexibility mechanisms allowed under the protocol, has the potential to reduce carbon leakage significantly because it reduces the relative competitive disadvantage to Annex B countries of restricting greenhouse gas emissions. The economic intuition behind this mechanism is explored in a theoretical analysis. It is then analyzed numerically using a CGE model. The results indicate that, assuming appropriate accounting for leakage and under realistic assumptions on CDM activity, the CDM has the potential to reduce the magnitude of carbon leakage by around three fifths

  2. Modelling and simulating the transitory regimes in NPP using the MMS package programs

    International Nuclear Information System (INIS)

    Prisecaru, I.; Dupleac, Daniel; Constantinescu, Adrian Cornel

    2003-01-01

    This paper introduces a brief presentation of the preoccupation of modelling and simulating group at the Nuclear Power Plant Department of the Faculty of Power Plant Engineering in 'Politehnica' University of Bucharest in using the Modular Modeling System, MMS, package programs for the simulation of NPP transitory regimes. Nuclear power plants are large, non-linear systems with numerous interactions between its components. In the analysis of such complex systems, dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. The MMS is a simulation tool that has built in models for plant components using a modular approach to dynamic simulation. The MMS software modules were developed to correspond to plant components that are familiar to power plant engineers. The interface specifications of the modules were defined so that the modules can be interconnected analogously to components in the actual plant. For some components, several modules of differing complexity are available. These alternative modules allow the user to choose the module appropriate to his application, i.e. a detailed model or a more economical model with less detail. The modular nature of the MMS allows the user to tailor the goal of his simulation to the complexity of the application and allows the user to develop independent subsystems that can be integrated into a larger simulation. The MMS module library contains modules for components for fossil and nuclear power plants. Each module is a mathematical model of a type of plant component formulated from first principles. The MMS uses a simulation language that provides features to simplify the development of simulations. Features important to the development of the MMS are the macro capability, automatic sorting of modeling equations, and integration algorithms. The macro capability is used to express the modeling equations for an MMS module. Since modules may be used more than once in the same simulation

  3. Zero Time of Transitory Nuclear Events Derived by Parent-Daughter Systems

    International Nuclear Information System (INIS)

    Nir-El, Y.

    2014-01-01

    The detection and identification of a nuclear event that results in the dissemination of radioactive products into the environment can be realized by dating the age of the event. In order to correct observed activities for the decay since the occurrence of the event, the age must be known to a high level of confidence. Previous papers. described the method to date the age of a nuclear event by measuring the activity of two fission products, which constitute the clock in this application. Within the proficiency test programme for radionuclide laboratories supporting the CTBT, a simulated gamma spectrum with the characteristics of an atmospheric test of a Chinese thermonuclear device, was used to determine the zero time by calculating the theoretical peak area ratio of 95Nb/95Zr. Their approach used only the main gamma lines at 766 and 757 keV and assigned the same detection efficiency to both these close lines. Their methodology of calculating the uncertainty of zero time is subject to comments because it takes the sum of two components (nuclide ratio and activity ratio as function of time) in quadrature. In another paper, the activity of 95Nb as a function of time was presented without any development or expression for the zero time. Analytical equations for zero time and the associated uncertainty calculations were derived in a recent paper using a measured activity ratio of two nuclides and illustrating the procedure by data from the Chinese test. The evaluation of the zero time uncertainty was performed by a very large set of very complicated analytical equations. The present paper aims at developing a procedure to determine the zero time and its uncertainty in a transitory nuclear event by treating a parent-daughter system of 3 nuclides, where one daughter feeds the other one, in addition to its direct feeding by the decay of the parent

  4. Valve packing leakage monitoring device

    International Nuclear Information System (INIS)

    Ezekoye, L.I.

    1985-01-01

    A device for monitoring leakage of fluid across a seal in a component connected to a pressurized fluid system including a housing having a chamber with an inlet for receiving fluid leaking across the seal and an outlet. A positioning means is connected to an orifice plug so as to move the plug for permitting the fluid to be discharged through the orifice at the same rate at which it enters the first chamber and means for detecting the movement of the plug is provided to produce and output signal corresponding to the distance moved by the plug and thereby indicate flow rate. The positioning means compromise a piston attached to the plug by a hollow tube and springs, which at low flow rates locate the piston. When flow increases sufficiently pressure increases and urges the piston upwards. A magnetic portion of tube actuates a succession of proximity switches to indicate flow rate. (author)

  5. Forest Carbon Leakage Quantification Methods and Their Suitability for Assessing Leakage in REDD

    Directory of Open Access Journals (Sweden)

    Sabine Henders

    2012-01-01

    Full Text Available This paper assesses quantification methods for carbon leakage from forestry activities for their suitability in leakage accounting in a future Reducing Emissions from Deforestation and Forest Degradation (REDD mechanism. To that end, we first conducted a literature review to identify specific pre-requisites for leakage assessment in REDD. We then analyzed a total of 34 quantification methods for leakage emissions from the Clean Development Mechanism (CDM, the Verified Carbon Standard (VCS, the Climate Action Reserve (CAR, the CarbonFix Standard (CFS, and from scientific literature sources. We screened these methods for the leakage aspects they address in terms of leakage type, tools used for quantification and the geographical scale covered. Results show that leakage methods can be grouped into nine main methodological approaches, six of which could fulfill the recommended REDD leakage requirements if approaches for primary and secondary leakage are combined. The majority of methods assessed, address either primary or secondary leakage; the former mostly on a local or regional and the latter on national scale. The VCS is found to be the only carbon accounting standard at present to fulfill all leakage quantification requisites in REDD. However, a lack of accounting methods was identified for international leakage, which was addressed by only two methods, both from scientific literature.

  6. Radiofrequency radiation leakage from microwave ovens

    International Nuclear Information System (INIS)

    Lahham, A.; Sharabati, A.

    2013-01-01

    This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm -1 with an average value equalling 3.64 μW cm -2 . Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm -2 . The highest radiation leakage from any tested oven was ∼16.4 μW cm -2 , and found in two cases only. In no case did the leakage exceed the limit of 1 μWcm -1 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age. (authors)

  7. Leakage-resilient cryptography from minimal assumptions

    DEFF Research Database (Denmark)

    Hazay, Carmit; López-Alt, Adriana; Wee, Hoeteck

    2013-01-01

    We present new constructions of leakage-resilient cryptosystems, which remain provably secure even if the attacker learns some arbitrary partial information about their internal secret key. For any polynomial ℓ, we can instantiate these schemes so as to tolerate up to ℓ bits of leakage. While the...

  8. Predicting Envelope Leakage in Attached Dwellings

    Energy Technology Data Exchange (ETDEWEB)

    Faakye, O. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Arena, L. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Griffiths, D. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  9. Leakage of caesium braquitherapy sources

    International Nuclear Information System (INIS)

    Lozada, J.A.

    1998-01-01

    In several Venezuelan public hospitals where cervix uteri tumours are treated by intracavitary radiotherapy, that use manual after loading Fletcher method, with Caesium 137 sources, the use of improper source holders, locally manufactured from pieces of drainage plastic tubing, which deteriorated and created a corrosive environment all around the sources, omission of manufacturer's recommendations regarding corrosion information, source storage, inspection and testing, violation of International Atomic Energy Agency Radiation Protection Procedures, and lack of proper regulatory control, resulted integrity damage to about sixty special form sources (ISO2919 C 63322), leakage of Cs-137 from a supposed insoluble refractory active content (caesium silicoaluminate), and contamination of applicators, floors and bedding. When the situation was detected by means removal contamination tests, after routine inspections, the sources were removed from the hospitals, decontaminated by means of immersion in 3% EDTA solution in ultrasonic bath, subjected to leaking assessment tests, and the ones that passed were placed in low cost stainless steel source holders, designed and built by the instituto Venezolano de Investigaciones Cientificas (IVIC) returned to the hospitals. The leaking sources were removed from use and considered radioactive waste. In order to avoid the occurrence of similar situations, all the importers of such sources are now required to send them to IVIC for testing and placement in proper source holders, before they are shipped to the hospitals. (author)

  10. Climate Policy and Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    This report explores the effects of the EU emissions trading scheme on the aluminium sector (i.e. competitiveness loss and carbon leakage). With its very high electricity intensity, primary aluminium stands out in the heavy industry picture: a sector whose emissions are not capped in the present EU ETS, European aluminium smelters still stand to lose profit margins and, possibly, market shares, as electricity prices increase following CO2 caps on generators' emissions - the famous pass-through of CO2 prices into electricity prices. The analysis includes a method of quantification of this issue, based on two indicators: profit margins and trade flows. As the EU is at the forefront of such policy, the paper provides policy messages to all countries on how trade exposed energy-intensive industries can be 'moved' by carbon constraint. This also is a contentious topic in Australia, Japan, New Zealand, and the US, where ambitious climate policies -- including cap-and-trade systems -- are currently debated.

  11. Experimental evaluation of clinical colon anastomotic leakage.

    Science.gov (United States)

    Pommergaard, Hans-Christian

    2014-03-01

    Colorectal anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. Patient and procedure related risk factors for anastomotic leakage have been identified. However, the responsible pathophysiological mechanisms are still unknown. Among these, ischemia and insufficient surgical technique have been suggested to play a central role. Animal models are valuable means to evaluate pathophysiological mechanisms and may be used to test preventive measures aiming at reducing the risk of anastomotic leakage, such as external anastomotic coating. The aim of this thesis was to: Clarify the best suited animal to model clinical anastomotic leakage in humans; Create animal models mimicking anastomotic leakage in humans induced by insufficient surgical technique and tissue ischemia; Determine the best suited coating materials to prevent anastomotic leakage. This study is a systematic review using the databases MEDLINE and Rex. MEDLINE was searched up to October 2010 to identify studies on experimental animal models of clinical colon anastomotic leakage. From the Rex database, textbooks on surgical aspects as well as gastrointestinal physiology and anatomy of experimental animals were identified. The results indicated that the mouse and the pig are the best suited animals to evaluate clinical anastomotic leakage. However, the pig model is less validated and more costly to use compared with the mouse. Most frequently, rats are used as models. However, extreme interventions are needed to create clinical leakage in these animals. The knowledge from this study formed the basis for selecting the animal species most suited for the models in the next studies. STUDY 2: In this experimental study, technically insufficient colonic anastomoses were performed in 110 C57BL/6 mice. The number of sutures in the intervention group was reduced to produce a suitable leakage rate. Moreover, the analgesia and suture material were changed in order to optimize the

  12. Leakage Resilient Secure Two-Party Computation

    DEFF Research Database (Denmark)

    Damgård, Ivan Bjerre; Hazay, Carmit; Patra, Arpita

    2012-01-01

    we initiate the study of {\\em secure two-party computation in the presence of leakage}, where on top of corrupting one of the parties the adversary obtains leakage from the content of the secret memory of the honest party. Our study involves the following contributions: \\BE \\item {\\em Security...... and returns its result. Almost independently of secure computation, the area of {\\em leakage resilient cryptography} has recently been evolving intensively, studying the question of designing cryptographic primitives that remain secure even when some information about the secret key is leaked. In this paper...

  13. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  14. IMPACT OF JUTE RETTING ON NATIVE FISH DIVERSITY AND AQUATIC HEALTH OF ROADSIDE TRANSITORY WATER BODIES: AN ASSESSMENT IN EASTERN INDIA

    Directory of Open Access Journals (Sweden)

    Dipankar Ghosh

    2015-09-01

    Full Text Available Roadside transitory water bodies being manmade depressions have a great ecological and socio-economic importance from years. The effects of agricultural runoffs, jute retting, macro-phytes infestations and inadequate rainfall in changed climate often degrade transitory water bodies’ environment while the biodiversity have impacted severely because of population pressure, over exploitation and indiscriminate use of fine meshed fishing gears as a whole. Physico-chemical and biological analysis with fish species composition, relative abundance, diversity indices like species richness, evenness and Shannon-Wiener index were carried out for pre-, during and post-jute retting season and for year mean as a whole to assess impact of jute retting on the roadside transitory water body’s environmental health and indigenous fish diversity at Sahebnagar village in Nadia District, India. All the physico-chemical parameters barring biochemical oxygen demand and water transparency remained more or less same or marginally got little changed during those three seasons. As much as 19 native fish species with varied relative abundances and dominances were identified. Jute retting impacted lower native fish diversity indices like Shannon-Wiener index values (1.94 to 2.68 clearly indicated poor to moderate pollution status of the transitory water body in that area during monsoon in particular and throughout the year in general. So we opined there should be some control over the intense jute retting in the road side transitory water bodies for sustainable management of these manmade resources.

  15. Do Transit-Oriented Developments (TODs) and Established Urban Neighborhoods Have Similar Walking Levels in Hong Kong?

    Science.gov (United States)

    Lu, Yi; Gou, Zhonghua; Xiao, Yang; Sarkar, Chinmoy; Zacharias, John

    2018-03-20

    A sharp drop in physical activity and skyrocketing obesity rate has accompanied rapid urbanization in China. The urban planning concept of transit-oriented development (TOD) has been widely advocated in China to promote physical activity, especially walking. Indeed, many design features thought to promote walking-e.g., mixed land use, densification, and well-connected street network-often characterize both TODs and established urban neighborhoods. Thus, it is often assumed that TODs have similar physical activity benefits as established urban neighborhoods. To verify this assumption, this study compared walking behaviors in established urban neighborhoods and transit-oriented new towns in Hong Kong. To address the limitation of self-selection bias, we conducted a study using Hong Kong citywide public housing scheme, which assigns residents to different housing estates by flat availability and family size rather than personal preference. The results show new town residents walked less for transportation purpose than urban residents. New town residents far from the transit station (800-1200 m) walked less for recreational purpose than TOD residents close to a rail transit station (transit stations.

  16. Do Transit-Oriented Developments (TODs) and Established Urban Neighborhoods Have Similar Walking Levels in Hong Kong?

    Science.gov (United States)

    Xiao, Yang; Sarkar, Chinmoy; Zacharias, John

    2018-01-01

    A sharp drop in physical activity and skyrocketing obesity rate has accompanied rapid urbanization in China. The urban planning concept of transit-oriented development (TOD) has been widely advocated in China to promote physical activity, especially walking. Indeed, many design features thought to promote walking—e.g., mixed land use, densification, and well-connected street network—often characterize both TODs and established urban neighborhoods. Thus, it is often assumed that TODs have similar physical activity benefits as established urban neighborhoods. To verify this assumption, this study compared walking behaviors in established urban neighborhoods and transit-oriented new towns in Hong Kong. To address the limitation of self-selection bias, we conducted a study using Hong Kong citywide public housing scheme, which assigns residents to different housing estates by flat availability and family size rather than personal preference. The results show new town residents walked less for transportation purpose than urban residents. New town residents far from the transit station (800–1200 m) walked less for recreational purpose than TOD residents close to a rail transit station (urban residents. The observed disparity in walking behaviors challenges the common assumption that TOD and established urban neighborhoods have similar impact on walking behavior. The results suggest the necessity for more nuanced planning strategies, taking local-level factors into account to promote walking of TOD residents who live far from transit stations. PMID:29558379

  17. Do Transit-Oriented Developments (TODs and Established Urban Neighborhoods Have Similar Walking Levels in Hong Kong?

    Directory of Open Access Journals (Sweden)

    Yi Lu

    2018-03-01

    Full Text Available A sharp drop in physical activity and skyrocketing obesity rate has accompanied rapid urbanization in China. The urban planning concept of transit-oriented development (TOD has been widely advocated in China to promote physical activity, especially walking. Indeed, many design features thought to promote walking—e.g., mixed land use, densification, and well-connected street network—often characterize both TODs and established urban neighborhoods. Thus, it is often assumed that TODs have similar physical activity benefits as established urban neighborhoods. To verify this assumption, this study compared walking behaviors in established urban neighborhoods and transit-oriented new towns in Hong Kong. To address the limitation of self-selection bias, we conducted a study using Hong Kong citywide public housing scheme, which assigns residents to different housing estates by flat availability and family size rather than personal preference. The results show new town residents walked less for transportation purpose than urban residents. New town residents far from the transit station (800–1200 m walked less for recreational purpose than TOD residents close to a rail transit station (<400 m or urban residents. The observed disparity in walking behaviors challenges the common assumption that TOD and established urban neighborhoods have similar impact on walking behavior. The results suggest the necessity for more nuanced planning strategies, taking local-level factors into account to promote walking of TOD residents who live far from transit stations.

  18. Signal attenuation due to cavity leakage

    International Nuclear Information System (INIS)

    Sherman, M.H.; Modera, M.P.

    1988-01-01

    The propagation of sound waves in fluids requires information about three properties of the system: capacitance (compressibility), resistance (friction), and inductance (inertia). Acoustical design techniques to date have tended to ignore the frictional effects associated with airflow across the envelope of the acoustic cavity (e.g., resistive vents). Since such leakage through the cavity envelope is best expressed with a power law dependence on the pressure, standard Fourier techniques that rely on linearity cannot be used. In this article, the theory relevant to nonlinear leakage is developed and equations presented. Potential applications of the theory to techniques for quantifying the leakage of buildings are presented. Experimental results from pressure decays in a full-scale test structure are presented and the leakage so measured is compared with independent measurements to demonstrate the technique

  19. Apparatus for detecting leakage of liquid sodium

    Science.gov (United States)

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  20. Electroplating eliminates gas leakage in brazed areas

    Science.gov (United States)

    Leigh, J. D.

    1966-01-01

    Electroplating method seals brazed or welded joints against gas leakage under high pressure. Any conventional electroplating process with many different metal anodes can be used, as well as the build up of layers of different metals to any required thickness.

  1. Analysis of ONKALO water leakage mapping results

    International Nuclear Information System (INIS)

    Ahokas, H.; Nummela, J; Turku, J.

    2014-04-01

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  2. Analysis of ONKALO water leakage mapping results

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Nummela, J; Turku, J. [Poeyry Finland Oy, Vantaa (Finland)

    2014-04-15

    As part of the programme for the final disposal of spent nuclear fuel, an analysis has been compiled of water leakage mapping performed in ONKALO. Leakage mapping is part of the Olkiluoto Monitoring Programme (OMO) and the field work has been carried out by Posiva Oy. The main objective of the study is to analyse differences detected between mapping campaigns carried out typically twice a year in 2005-2012. Differences were estimated to be caused by the differences in groundwater conditions caused by seasonal effects or by differences between the years. The effect of technical changes like shotcreting, postgrouting, ventilation etc. on the results was also studied. The development of the visualisation of mapping results was also an objective of this work. Leakage mapping results have been reported yearly in the monitoring reports of Hydrology with some brief comments on the detected differences. In this study, the development of the total area and the number of different leakages as well as the correlation of changes with shotcreting and grouting operations were studied. In addition, traces of fractures on tunnel surfaces, and the location of rock bolts and drain pipes were illustrated together with leakage mapping. In water leakage mapping, the tunnel surfaces are visually mapped to five categories: dry, damp, wet, dripping and flowing. Major changes were detected in the total area of damp leakages. It is likely that the increase has been caused by the condensation of warm ventilation air on the tunnel surfaces and the corresponding decrease by the evaporation of moisture into the dry ventilation air. Shotcreting deep in ONKALO may also have decreased the total area of damp leakages. Changes in the total area and number of wet leakages correlate at least near the surface with differences in yearly precipitation. It is possible that strong rains have also caused a temporary increase in wet leakages. Dripping and wet leakages have been observed on average more

  3. Technology evaluation for space station atmospheric leakage

    Energy Technology Data Exchange (ETDEWEB)

    Lemon, D.K.; Friesel, M.A.; Griffin, J.W.; Skorpik, J.R.; Shepard, C.L.; Antoniak, Z.I.; Kurtz, R.J.

    1990-02-01

    A concern in operation of a space station is leakage of atmosphere through seal points and through the walls as a result of damage from particle (space debris and micrometeoroid) impacts. This report describes a concept for a monitoring system to detect atmosphere leakage and locate the leak point. The concept is based on analysis and testing of two basic methods selected from an initial technology survey of potential approaches. 18 refs., 58 figs., 5 tabs.

  4. Carbon leakage from a Nordic perspective

    Energy Technology Data Exchange (ETDEWEB)

    Naess-Schmidt, S.; Hansen, Martin Bo; Sand Kirk, J. [Copenhagen Economics, Copenhagen (Denmark)

    2012-02-15

    Carbon pricing is generally considered a highly effective tool in reducing carbon emissions. Putting a price on carbon provides incentives for users and producers of fossil fuels to reduce consumption and develop low carbon products and processes. However, pursuing an ambitious climate policy can lead to carbon leakage, which refers to a situation where unilateral or regional climate change policy drives the relocation of industry investments and installations, and associated emissions, to third countries. This report by Copenhagen Economics has been commissioned by the Nordic Council of Ministers to give an overview of the industries at risk of carbon leakage in the Nordic countries, and estimate the expected extent of carbon leakage from unilateral climate policies in the Nordic countries. The report also assesses available policy options that may reduce the risk of carbon leakage, such as exemptions from energy tax and exemptions from quota obligations under green certificate schemes. The key drivers of carbon leakage are identified, which include energy intensity, product differentiation, transportation costs and capital intensity. The analysis suggests that industries such as paper and pulp, iron and steel, aluminium, cement, pharmaceuticals, chemicals, and fertilizers are most at risk of carbon leakage in the Nordic manufacturing sector. (Author)

  5. Application of the FFTBM method and the power relative contribution to the discharge transitory of the recirculation pumps of a BWR

    International Nuclear Information System (INIS)

    Castillo D, R.; Ortiz V, J.; Fuentes M, L.

    2013-10-01

    In this work was realized the simulation of the discharge transitory of both recirculation pumps of a BWR with the Simulate-3K code. This type of transitory is used in the stability analyses for the licensing of the fuel reload. An analysis of the precision of the simulation is also presented, using the FFTBM method jointly with the power relative contribution. This way, instead of determining the total precision of the calculation, a weighed precision is obtained by the contribution of each relevant parameter of the transitory. The results show that the precision of the simulation is acceptable due to the small magnitude of the merit figure of the width total average. The error in the merit figure comes mainly from the parameters total flow in the core and temperature of the fuel in the core. (Author)

  6. Pickering unit 1 containment leakage characterization

    International Nuclear Information System (INIS)

    Zakaib, G.D.

    1994-01-01

    Results of the design pressure test carried out on Pickering Reactor Building number 1 during late 1992 showed that the leakage rate of the building was close to the safety analysis value of 2.7% contained mass per hour at the design pressure of 41.4 kPa(g) and was significantly higher than that reported after the previous test conducted in the spring of 1987. This unexpected finding initiated the longest and the most comprehensive containment leakage investigation ever undertaken by Ontario Hydro. A thorough investigation of leakage behaviour by repeated testing, inspections, leak search and analysis was launched. The extensive leak search effort included items such as: leak source detection by soap solution application, use of ultrasonic detectors, fogging and tracer gas techniques, systematic systems isolation, thermal imaging of the exterior, and quantification of leak sites by flowmeter and bagging. Using a specially designed volumetric technique, the root cause of the problem was finally confirmed as being due to 'pressure dependent laminar leakage' through the hairline cracks in the dome concrete. Structural analysis indicated that the thermal gradients and pressure loading combined to cause the cracking early in the structure's operating history and that overall structural integrity has not been compromised. Leakage rate analysis using a new fluid mechanics model augmented by the effect of thermal strains indicated that the leakage could be significantly less under certain transient temperature gradient conditions. Several options for repairing the dome were considered by a multidisciplinary team and it was finally decided to apply a specially engineered multilayer elastomeric coating to the exterior concrete surface. When the unit was re-tested in October 1993, a dramatic ten-fold improvement in leakage rate (down to 0.25%/h at design pressure) was observed. This is lower than even the commissioning results and comparable to the performance of newer units

  7. How to attribute market leakage to CDM projects

    NARCIS (Netherlands)

    Vöhringer, F.; Kuosmanen, T.K.; Dellink, R.B.

    2006-01-01

    Economic studies suggest that market leakage rates of greenhouse gas abatement can reach the two-digit percentage range. Although the Marrakesh Accords require Clean Development Mechanism (CDM) projects to account for leakage, most projects neglect market leakage. Insufficient leakage accounting is

  8. Calculation of Leakage Inductance for High Frequency Transformers

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Jun, Zhang; Hurley, William Gerard

    2015-01-01

    Frequency dependent leakage inductance is often observed. High frequency eddy current effects cause a reduction in leakage inductance. The proximity effect between adjacent layers is responsible for the reduction of leakage inductance. This paper gives a detailed analysis of high frequency leakag...

  9. Determination of leakage areas in nuclear piping

    International Nuclear Information System (INIS)

    Keim, E.

    1997-01-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack

  10. Sustainable management of leakage from wastewater pipelines.

    Science.gov (United States)

    DeSilva, D; Burn, S; Tjandraatmadja, G; Moglia, M; Davis, P; Wolf, L; Held, I; Vollertsen, J; Williams, W; Hafskjold, L

    2005-01-01

    Wastewater pipeline leakage is an emerging concern in Europe, especially with regards to the potential effect of leaking effluent on groundwater contamination and the effects infiltration has on the management of sewer reticulation systems. This paper describes efforts by Australia, in association with several European partners, towards the development of decision support tools to prioritize proactive rehabilitation of wastewater pipe networks to account for leakage. In the fundamental models for the decision support system, leakage is viewed as a function of pipeline system deterioration. The models rely on soil type identification across the service area to determine the aggressiveness of the pipe environment and for division of the area into zones based on pipe properties and operational conditions. By understanding the interaction between pipe materials, operating conditions, and the pipe environment in the mechanisms leading to pipe deterioration, the models allow the prediction of leakage rates in different zones across a network. The decision support system utilizes these models to predict the condition of pipes in individual zones, and to optimize the utilization of rehabilitation resources by targeting the areas with the highest leakage rates.

  11. Determination of leakage areas in nuclear piping

    Energy Technology Data Exchange (ETDEWEB)

    Keim, E. [Siemens/KWU, Erlangen (Germany)

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  12. Analogical reasoning and the differential outcome effect: transitory bridging of the conceptual gap for rhesus monkeys (Macaca mulatta).

    Science.gov (United States)

    Flemming, Timothy M; Thompson, Roger K R; Beran, Michael J; Washburn, David A

    2011-07-01

    Monkeys, unlike chimpanzees and humans, have a marked difficulty acquiring relational matching-to-sample (RMTS) tasks that likely reflect the cognitive foundation upon which analogical reasoning rests. In the present study, rhesus monkeys (Macaca mulatta) completed a categorical (identity and nonidentity) RMTS task with differential reward (pellet ratio) and/or punishment (timeout ratio) outcomes for correct and incorrect choices. Monkeys in either differential reward-only or punishment-only conditions performed at chance levels. However, the RMTS performance of monkeys experiencing both differential reward and punishment conditions was significantly better than chance. Subsequently when all animals experienced nondifferential outcomes tests, their RMTS performance levels were at chance. These results indicate that combining differential reward and punishment contingencies provide an effective, albeit transitory, scaffolding for monkeys to judge analogical relations-between-relations. PsycINFO Database Record (c) 2011 APA, all rights reserved

  13. Component external leakage and rupture frequency estimates

    International Nuclear Information System (INIS)

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results

  14. Leakage-Resilient Circuits without Computational Assumptions

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2012-01-01

    Physical cryptographic devices inadvertently leak information through numerous side-channels. Such leakage is exploited by so-called side-channel attacks, which often allow for a complete security breache. A recent trend in cryptography is to propose formal models to incorporate leakage...... on computational assumptions, our results are purely information-theoretic. In particular, we do not make use of public key encryption, which was required in all previous works...... into the model and to construct schemes that are provably secure within them. We design a general compiler that transforms any cryptographic scheme, e.g., a block-cipher, into a functionally equivalent scheme which is resilient to any continual leakage provided that the following three requirements are satisfied...

  15. Markovian Processes for Quantitative Information Leakage

    DEFF Research Database (Denmark)

    Biondi, Fabrizio

    Quantification of information leakage is a successful approach for evaluating the security of a system. It models the system to be analyzed as a channel with the secret as the input and an output as observable by the attacker as the output, and applies information theory to quantify the amount...... and randomized processes with Markovian models and to compute their information leakage for a very general model of attacker. We present the QUAIL tool that automates such analysis and is able to compute the information leakage of an imperative WHILE language. Finally, we show how to use QUAIL to analyze some...... of information transmitted through such channel, thus effectively quantifying how many bits of the secret can be inferred by the attacker by analyzing the system’s output. Channels are usually encoded as matrices of conditional probabilities, known as channel matrices. Such matrices grow exponentially...

  16. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the 13 N content in the containment atmosphere. 13 N is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/ 13 N+ 4 He. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium 13 N concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  17. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1980-01-01

    This study deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process Hl+016/yields/Nl3+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m/sup -3/ and 7 kBq m/sup -3/ for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge(Li) flow detector assembly operated at elevated pressure. 8 refs

  18. Reactor coolant pressure boundary leakage detection system

    International Nuclear Information System (INIS)

    Dissing, E.; Svansson, L.

    1979-08-01

    The present paper deals with a system for monitoring the leakage of reactor coolant. This system is based primarily on the detection of the N13 content in the containment atmosphere. N13 is produced from the oxygen of the reactor water via the recoil proton nuclear process H1+016 → N13+He4. The generation is therefore independent of fuel element leakage and of the corrosion product content in the water. It is solely related to the neutron flux level in the reactor core. Typical figures for the equilibrium N13 concentration in the containment atmosphere following a 4 kg/minute coolant leakage are 5 kBq m -3 and 7 kBq m -3 for BWR and PWR respectively. These levels are readily measured with a 10 liter Ge (Li) flow detector assembly operated at elevated pressure. (Auth.)

  19. Quantifying information leakage of randomized protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Legay, Axel; Malacaria, Pasquale

    2015-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model deterministic and probabilistic systems. By using a methodology generalizing the lattice of information approach we model refined attackers...... capable to observe the internal behavior of the system, and quantify the information leakage of such systems. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed and non-timed attacks...

  20. Quantifying Information Leakage of Randomized Protocols

    DEFF Research Database (Denmark)

    Biondi, Fabrizio; Wasowski, Andrzej; Legay, Axel

    2013-01-01

    The quantification of information leakage provides a quantitative evaluation of the security of a system. We propose the usage of Markovian processes to model and analyze the information leakage of deterministic and probabilistic systems. We show that this method generalizes the lattice...... of information approach and is a natural framework for modeling refined attackers capable to observe the internal behavior of the system. We also use our method to obtain an algorithm for the computation of channel capacity from our Markovian models. Finally, we show how to use the method to analyze timed...

  1. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  2. The Leakage determination on corrosion fretting machine

    International Nuclear Information System (INIS)

    Sriyono; Satmoko, Ari; Hafid, Abdul; Febrianto; Prasetio, Joko; Abtokhi; Sumarno, Edy; Handoyo, Ismu; Hidayati, Nur Rahmah; Histori

    1998-01-01

    Fretting machine is an experimental loop to learn fretting corrosion phenomena wich is caused by loading and vibration. On the steam generator, one of the corrosion process that's occurred, it can be caused by vibration between tubes and bending material. Because of high flow rate inside the tube, the high frequency vibration will appeared so it can make the corrosion on bending material more faster. This process can be simulate by fretting machine. This machine has already damage because of leakage. So it will be repaired by dismantling, radiography testing and redrawing. from the result of radiography, the leakage is caused by cracking on bellows seals of the dynamic main support

  3. Integral leakage rate tests of containments

    International Nuclear Information System (INIS)

    Engel, M.; Siefart, E.; Walter, R.

    1978-01-01

    A method is presented for the integral leakage rate tests of containments. This method, used in conjunction with statistical methods, provides reliable information on the tightness of the containment. This method forms the basis of DIN 25436/KTA 3405. (orig.) [de

  4. Poloidal field leakage optimization in ETE

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Carlos Shinya; Montes, Antonio

    1996-12-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs.

  5. The concept of leakage in threat assessment.

    Science.gov (United States)

    Meloy, J Reid; O'Toole, Mary Ellen

    2011-01-01

    Leakage in the context of threat assessment is the communication to a third party of an intent to do harm to a target. Third parties are usually other people, but the means of communication vary, and include letters, diaries, journals, blogs, videos on the internet, emails, voice mails, and other social media forms of transmission. Leakage is a type of warning behavior that typically infers a preoccupation with the target, and may signal the research, planning, and implementation of an attack. Nomothetic data suggest that leakage occurs in a majority of cases of attacks on and assassinations of public figures, adult mass murders, adolescent mass murders, and school or campus shootings: very low-frequency, but catastrophic acts of intended and targeted violence. Idiographic or case data illustrate the various permutations of leakage. We discuss the operational importance of the concept, place it in the context of other warning behaviors, emphasize the need for further research, and outline risk management strategies for the mitigation of such acts of violence in both law enforcement and clinical mental health settings. Copyright © 2011 John Wiley & Sons, Ltd.

  6. Secret rate - Privacy leakage in biometric systems

    NARCIS (Netherlands)

    Ignatenko, T.; Willems, F.M.J.

    2009-01-01

    Ahlswede and Csiszár [1993] introduced the concept of secret sharing. In their source model two terminals observe two correlated sequences. It is the objective of the terminals to form a common secret by interchanging a public message (helper data) in such a way that the secrecy leakage is

  7. Radiation leakage in nuclear ship 'MUTSU'

    International Nuclear Information System (INIS)

    Ando, Yoshio; Miyasaka, Shun-ichi; Takeuchi, Kiyoshi.

    1975-01-01

    Associated with the radiation leakage in MUTSU occurred in September 1974, this report reviews the shielding design for MUTSU, radiation measurement and inspection activities by a survey group, and 2 dimensional analysis on the behavior of fast neutrons to shielding based on Ssub(N) codes. In the first part, the purpose and the structure of the primary and the secondary shields of MUTSU are briefly illustrated. In the second part, the progress of the series of affairs is explained, starting from zero power criticality experiment, through discovery of radiation leakage in output-increasing test, sending of a survey group for various measurement and inspection, and finally to the conclusion drawn by the survey group. In the third part, various numerical analyses performed to investigate into the leakage are illustrated with their results. The transport codes used were ANISN, TWOTRAN, SPAN, and PALLAS-2DCY. As a result of those inspection and calculation, it was found that the radiation leakage was due to fast neutrons coming through the gap between the reactor vessel and the primary shield. (Aoki, K.)

  8. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  9. Poloidal field leakage optimization in ETE

    International Nuclear Information System (INIS)

    Shibata, Carlos Shinya; Montes, Antonio.

    1996-01-01

    A very simple but efficient numerical algorithm is used to minimize the Ohmic coil field leakage into the plasma region of the tokamak ETE. After few interactions the code provides the positions and the current required for two pairs of compensation coils. Resulting optimum field intensity distribution is presented and commented. (author). 5 refs., 4 figs., 2 tabs

  10. Zero leakage quantization scheme for biometric verification

    NARCIS (Netherlands)

    Groot, de J.A.; Linnartz, J.P.M.G.

    2011-01-01

    Biometrics gain increasing interest as a solution for many security issues, but privacy risks exist in case we do not protect the stored templates well. This paper presents a new verification scheme, which protects the secrets of the enrolled users. We will show that zero leakage is achieved if

  11. Acoustic control of sodium leakage in valve gates of NPP

    International Nuclear Information System (INIS)

    Trykov, E.L.; Kovtun, S.N.; Anan'ev, A.A.; Yugov, S.I.

    2014-01-01

    Short description of sodium bench and acoustic investigation results on leakage monitoring of valves DN10 and DN40 are given. It is shown that acoustic method can be used successfully to control the leakages of sodium valves. Leakages on both type of valves increase the acoustic signal dispersion by 2-3 orders. For each type of valve acoustic system of leakage determination allows to conduct the preliminary graduation of signal dispersion on the sodium discharge rate. It make possible not only to record the leakage presence but also to determine the sodium discharge rate through the valve during the leakage [ru

  12. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  13. Lung protein leakage in feline septic shock.

    Science.gov (United States)

    Schützer, K M; Larsson, A; Risberg, B; Falk, A

    1993-06-01

    The aim of the present study was to explore lung microvascular leakage of protein and water in a feline model of septic shock, using a double isotope technique with external gamma camera detection and gravimetric lung water measurements. The experiments were performed on artificially ventilated cats. One group of cats (n = 8) was given an infusion of live Escherichia coli bacteria, and another group (n = 5) served as a control group receiving saline. Plasma transferrin was radiolabeled in vivo with indium-113m-chloride, and erythrocytes were labeled with technetium-99m. The distribution of these isotopes in the lungs was continuously measured with a gamma camera. A normalized slope index (NSI) was calculated, indicative of the transferrin accumulation corrected for changes in local blood volume that reflect protein leakage. In the septic group there was a protein leakage after bacterial infusion, with a NSI of 39 x 10(-4) +/- 5 x 10(-4) min-1 (mean +/- SEM), and the PaO2 diminished from 21 +/- 1 to 9.5 +/- 1 kPa. In control cats a slight protein leakage with a NSI of 9 +/- 10(-4) +/- 2 x 10(-4) min-1 was detected, probably caused by the operative procedure, but PaO2 did not change. Wet-to-dry-weight ratios of postmortem lungs were not significantly different between the groups. It was concluded that an intravenous infusion of live E. coli bacteria induces a lung capillary protein leakage without increased lung water and a concomitantly disturbed gas exchange.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Pancreatic anastomosis leakage management following pancreaticoduodenectomy how could be manage the anastomosis leakage after pancreaticoduodenectomy?

    Directory of Open Access Journals (Sweden)

    Seyed Abbas Tabatabei

    2015-01-01

    Full Text Available Background: Pancreatic anastomosis leakage and fistula formation following pancreaticoduodenectomy (Whipple′s procedure is a common complication. Delay in timely diagnosis and proper management is associated with high morbidity and mortality. To report our experience with management of pancreatic fistula following Whipple′s procedure. Materials and Methods: In this retrospective study, medical records of 90 patients who underwent Whipple′s procedure from 2009 to 2013 at our medical center were reviewed for documents about pancreatic anastomosis leakage and fistula formation. Results: There were 15 patients who developed pancreatico-jejunal anastomosis leakage. In 6 patients (3 males and 3 females the leakage was mild (conservative therapy was administered, but in 9 patients (6 males and 3 females, there was severe leakage. For the latter group, surgical intervention was done (2 cases underwent re-anastomosis and for 7 cases pancreatico-jejunal stump ligation was done along with drainage of the location. Conclusion: In severe pancreatic anastomotic leakage, it is better to intervene surgically as soon as possible by debridement of the distal part of the pancreas and ligation of the stump with nonabsorbable suture. Furthermore, debridement of the jejunum should be done, and the stump should be ligated thoroughly along with drainage.

  15. Incidence and management of pancreatic leakage after pancreatoduodenectomy

    NARCIS (Netherlands)

    de Castro, S. M. M.; Busch, O. R. C.; van Gulik, T. M.; Obertop, H.; Gouma, D. J.

    2005-01-01

    Background: Optimal management of severe pancreatic leakage after pancreatoduodenectomy can reduce morbidity and mortality. Completion pancreatectomy may be adequate but leads to endocrine insufficiency. This study evaluated an alternative management strategy for pancreatic leakage. Methods: Outcome

  16. Multiple leakage localization and leak size estimation in water networks

    NARCIS (Netherlands)

    Abbasi, N.; Habibi, H.; Hurkens, C.A.J.; Klabbers, M.D.; Tijsseling, A.S.; Eijndhoven, van S.J.L.

    2012-01-01

    Water distribution networks experience considerable losses due to leakage, often at multiple locations simultaneously. Leakage detection and localization based on sensor placement and online pressure monitoring could be fast and economical. Using the difference between estimated and measured

  17. A new method to detect transitory signatures and local time/space variability structures in the climate system: the scale-dependent correlation analysis

    Science.gov (United States)

    Rodó, Xavier; Rodríguez-Arias, Miquel-Àngel

    2006-10-01

    The study of transitory signals and local variability structures in both/either time and space and their role as sources of climatic memory, is an important but often neglected topic in climate research despite its obvious importance and extensive coverage in the literature. Transitory signals arise either from non-linearities, in the climate system, transitory atmosphere-ocean couplings, and other processes in the climate system evolving after a critical threshold is crossed. These temporary interactions that, though intense, may not last long, can be responsible for a large amount of unexplained variability but are normally considered of limited relevance and often, discarded. With most of the current techniques at hand these typology of signatures are difficult to isolate because the low signal-to-noise ratio in midlatitudes, the limited recurrence of the transitory signals during a customary interval of data considered. Also, there is often a serious problem arising from the smoothing of local or transitory processes if statistical techniques are applied, that consider all the length of data available, rather than taking into account the size of the specific variability structure under investigation. Scale-dependent correlation (SDC) analysis is a new statistical method capable of highlighting the presence of transitory processes, these former being understood as temporary significant lag-dependent autocovariance in a single series, or covariance structures between two series. This approach, therefore, complements other approaches such as those resulting from the families of wavelet analysis, singular-spectrum analysis and recurrence plots. A main feature of SDC is its high-performance for short time series, its ability to characterize phase-relationships and thresholds in the bivariate domain. Ultimately, SDC helps tracking short-lagged relationships among processes that locally or temporarily couple and uncouple. The use of SDC is illustrated in the present

  18. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  19. Performance-based containment leakage testing

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1995-01-01

    The U.S. Nuclear Regulatory Commission (NRC) is reviewing regulatory requirements in an effort to revise those that are marginal to safety but impose significant burdens on licensees. Identification of requirements marginal to safety and development and evaluation of alternatives utilize the NRC safety goals and insights from probabilistic risk assessments (PRAs). Since earlier studies found design-basis containment leakage to be a minor contributor to reactor accident risk, containment leakage testing has been selected as a candidate for change in regulations. This paper summarizes the technical analyses supporting the NRC proposal to amend Appendix J of 10 CFR Part 50 as its first effort to decrease unnecessary regulatory burdens on licensees

  20. Methane leakage in natural gas operations

    International Nuclear Information System (INIS)

    Jennervik, A.

    1992-01-01

    The world gas industry is efficient in conservation of natural gas within its systems. As the influence of methane as an infra-red absorbent gas has been more widely recognized, the considerations of methane's greenhouse effect has become vitally important to gas companies around the world. The industry is universally environmentally conscious. natural gas transmission and distribution companies want to maintain their image as suppliers of clean fuel. Further reductions in methane leakage --- particularly in older distribution systems --- can, should and will be pursued. Unfortunately, there has been little exchange of views on methane leakages between commentators on environmental matters and gas companies and organizations. There is absolutely no need for the industry to avoid the issue of greenhouse gases. Without industry involvement, the environmental debate concerning fossil fuels could lead to selective interpretation of scientific views and available evidence. Companies and authorities would be presented with confusing, contradictory evidence on which to base policy approaches and regulations

  1. Measurement Methods to Determine Air Leakage Between Adjacent Zones

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Phillip N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-09-01

    Air leakage between adjacent zones of a building can lead to indoor air quality and energy efficiency concerns, however there is no existing standard for measuring inter-zonal leakage. In this study, synthesized data and field measurements are analyzed in order to explore the uncertainty associated with different methods for collecting and analyzing fan pressurization measurements to calculate interzone leakage.

  2. Numerical investigation of tip leakage vortex

    OpenAIRE

    Fredriksen, Vegard

    2017-01-01

    The Kaplan turbine has a small clearance gap between the blade tip and casing to allow the blades to rotate freely. This clearance gap is the cause of an undesirable Tip Leakage Vortex (TLV). A TLV might reduce the turbine efficiency, erode the turbine blades or cause instabilities for the power output. A literature study indicated that the tip clearance gap was a critical parameter affecting the behavior of the TLV. A research gap was observed for an operating Kaplan turbine where the ...

  3. Controlled Aerodynamic Loads on an Airfoil in Coupled Pitch/Plunge by Transitory Regulation of Trapped Vorticity

    Science.gov (United States)

    Tan, Yuehan; Crittenden, Thomas; Glezer, Ari

    2017-11-01

    The aerodynamic loads on an airfoil moving in coupled, time-periodic pitch-plunge beyond the static stall margin are controlled using transitory regulation of trapped vorticity concentrations. Actuation is effected by a spanwise array of integrated miniature chemical (combustion based) impulse actuators that are triggered intermittently during the airfoil's motion and have a characteristic time scale that is an order of magnitude shorter than the airfoil's convective time scale. Each actuation pulse effects momentary interruption and suspension of the vorticity flux with sufficient control authority to alter the airfoil's global aerodynamic characteristics throughout its motion cycle. The effects of the actuation are assessed using time-dependent measurements of the lift and pitching moment coupled with time-resolved particle image velocimetry over the airfoil and in its near wake that is acquired phased-locked to its motion. It is shown that while the presence of the pitch-coupled plunge delays lift and moment stall during upstroke, it also delays flow reattachment during the downstroke and results in significant degradation of the pitch stability. These aerodynamic shortcomings are mitigated using superposition of a limited number of pulses that are staged during the pitch/plunge cycle and lead to enhancement of cycle lift and pitch stability, and reduces the cycle hysteresis and peak pitching moment.

  4. Time reversal technique for gas leakage detection.

    Science.gov (United States)

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.

  5. THE PARTICIPATION OF THE NITRERGIC PATHWAY IN INCREASED RATE OF TRANSITORY RELAXATION OF LOWER ESOPHAGEAL SPHINCTER INDUCED BY RECTAL DISTENSION IN DOGS

    Directory of Open Access Journals (Sweden)

    Michel Santos PALHETA

    2014-04-01

    Full Text Available Context The rectal distension in dogs increases the rate of transitory lower esophageal sphincter relaxation considered the main factor causing gastroesophageal reflux. Objectives The aim of this study was evaluate the participation of the nitrergic pathway in the increased transitory lower esophageal sphincter relaxation rate induced by rectal distension in anesthetized dogs. Methods Male mongrel dogs (n = 21, weighing 10-15 kg, were fasted for 12 hours, with water ad libitum. Thereafter, they were anesthetized (ketamine 10 mg.Kg-1 + xylazine 20 mg.Kg-1, so as to carry out the esophageal motility evaluation protocol during 120 min. After a 30-minute basal period, the animals were randomly intravenous treated whith: saline solution 0.15M (1ml.Kg-1, L-NAME (3 mg.Kg-1, L-NAME (3 mg.Kg-1 + L-Arginine (200 mg.Kg-1, glibenclamide (1 mg.Kg-1 or methylene blue (3 mg.Kg-1. Forty-five min after these pre-treatments, the rectum was distended (rectal distension, 5 mL.Kg-1 or not (control with a latex balloon, with changes in the esophageal motility recorded over 45 min. Data were analyzed using ANOVA followed by Student Newman-Keuls test. Results In comparison to the respective control group, rectal distension induces an increase in transitory lower esophageal sphincter relaxation. Pre-treatment with L-NAME or methylene blue prevents (P<0.05 this phenomenon, which is reversible by L-Arginine plus L-NAME. However, pretreating with glibenclamide failed to abolish this process. Conclusions Therefore, these experiments suggested, that rectal distension increases transitory lower esophageal sphincter relaxation in dogs via through nitrergic pathways.

  6. Hypoplasia of the basi-occipital bone and persistance of the spheno-occipital synchondrosis in a patient with transitory supplementary fissure of the basi-occipital

    International Nuclear Information System (INIS)

    Wackenheim, A.

    1985-01-01

    The author had the opportunity to observe the progressive development of a special form of basilar impression characterized by transitory supplementary fissure of the basi-occipital bone, persistance of the spheno-occipital synchondrosis and hypoplasia of the basi-occipital. He proposes to dissociate the general concept of basilar impression and to consider anatomo-clinical entities such as the example described in this paper. (orig.)

  7. Alopecia associated with unexpected leakage from electron cone

    Energy Technology Data Exchange (ETDEWEB)

    Wen, B.C.; Pennington, E.C.; Hussey, D.H.; Jani, S.K.

    1989-06-01

    Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

  8. Radiation induced leakage current and stress induced leakage current in ultra-thin gate oxides

    International Nuclear Information System (INIS)

    Ceschia, M.; Paccagnella, A.; Cester, A.; Scarpa, A.

    1998-01-01

    Low-field leakage current has been measured in thin oxides after exposure to ionizing radiation. This Radiation Induced Leakage Current (RILC) can be described as an inelastic tunneling process mediated by neutral traps in the oxide, with an energy loss of about 1 eV. The neutral trap distribution is influenced by the oxide field applied during irradiation, thus indicating that the precursors of the neutral defects are charged, likely being defects associated to trapped holes. The maximum leakage current is found under zero-field condition during irradiation, and it rapidly decreases as the field is enhanced, due to a displacement of the defect distribution across the oxide towards the cathodic interface. The RILC kinetics are linear with the cumulative dose, in contrast with the power law found on electrically stressed devices

  9. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  10. Leakage warning system for flexible underwater pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, E; Bernstein, L

    1985-08-01

    Underwater pipelines for unloading oil tankers, e.g. in 30 km distance from the harbour site, are required to be flexible and require supervision. This is done by implementation of oil sensitive sensors between the inner rubber tube and the following impregnated textile layer. The generated sensor signals, influenced by leak oil, have to be wireless transmitted from 150 meters under water to the supervisory station at the coast. Sensor configurations are described, to derive the point of the leakage from the topologized warning signals.

  11. Facepiece leakage and fitting of respirators

    International Nuclear Information System (INIS)

    White, J.M.

    1978-05-01

    The ways in which airborne contaminants can penetrate respirators and the factors which affect the fit of respirators are discussed. The fit of the respirator to the face is shown to be the most critical factor affecting the protection achieved by the user. Qualitative and quantitative fit testing techniques are described and their application to industrial respirator programs is examined. Quantitative measurement of the leakage of a respirator while worn can be used to numerically indicate the protection achieved. These numbers, often referred to as protection factors, are sometimes used as the basis for selecting suitable respirators and this practice is reviewed. (author)

  12. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  13. Unusual dialysate leakage complicating peritoneal dialysis

    International Nuclear Information System (INIS)

    Chiu, Jainn-Shiun; Yu, Fu-Chiu; Chen, Chiou-An; Wang, Yuh-Feng

    2006-01-01

    A 16-year-old female who had end-stage renal disease on 2-month continuous ambulatory peritoneal dialysis (CAPD) presented with perineal pain 4 days before admission. The physical examination revealed bilateral labial edema. Peritoneal scintigraphy was requested after infusing 2 L peritoneal dialysate with direct administration of 370 MBq (10mCi) technetium-99m diethylenetriamine pentra-acetic acid into peritoneal cavity via Tenckhoff catheter. Radioactive uptake from right inguinal to labial region was clearly demonstrated, and this indicated the site of peritoneal leakage. After surgical intervention unilaterally, she continued CAPD without any recurrence (au)

  14. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage

    Czech Academy of Sciences Publication Activity Database

    Braun, S.; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, H.; Hoernke, M.

    2018-01-01

    Roč. 12, č. 1 (2018), s. 813-819 ISSN 1936-0851 R&D Projects: GA ČR GA17-03160S Institutional support: RVO:61388955 Keywords : leakage * dye release * pore Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 13.942, year: 2016

  15. Leakage in the Juelich research reactor

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    On August 17, 1978, a leakage occurred in the DIDO research reactor. Early in the afternoon of this day, the valves of the coolant loop had been checked with the reactor shut off. When the mechanics wanted to oil a tight valve and drilled a hole in the valve cover for this, heavy water started to leak (leakage in the valve membrane). The mechanics left the shielded valve space at once; directly after having a shower, they underwent a radiation protection examination. It was found that none of the mechanics had been exposed to an excessive dose. When other mechanics in protective suits had closed the leak in the valve, a total of 150 liters had leaked into the sump pump at the valve entrance. They were pumped back into the cooling system. About 5 liters of water were evaporated and, via the stack, escaped into the environment. The activity released was about 40 curie; this is less than the permissible amount of 60 curie per week during normal operation. Neither the KFA personnel nor the inhabitants of Juelich and its surroundings were in danger at any moment. Calculations so far yield a maximum radiation exposure below 1mrem at the point of maximum exposure. The cooling circuit could be entered again only one day after the incident. The present shut-off phase of the reactor is not unduly prolonged by this accident. (orig./HP) [de

  16. Leakage detection device for weld portion

    International Nuclear Information System (INIS)

    Shinkawa, Toshio; Setokuchi, Sadayuki.

    1994-01-01

    The present invention concerns leakage detection device for weld portions, for example, in a nuclear reactor cavity, which can rapidly detect by remote control. That is, a detection device capable of self running and stopping on a guide rail along a weld line is disposed. The detection device comprises a coating mechanism for automatically coating soap water to the weld portion, a vacuum box capable of evacuating the coated surface and a camera for detecting the presence or absence of the soap bubbles generated under the evacuation. Such a device can conduct, by remote control, self running/stopping along with the weld line, coating of the soap water, settling of the vacuum box and confirmation and recording of foaming by using a television monitor. Accordingly, leakage in the weld portion in the reactor cavity or the like can be inspected. As a result, it greatly contributes to improvement of danger upon worker's operation at high place, detection accuracy and reliability of detection and shortening of operation period. (I.S.)

  17. Leakage detection system in nuclear reactor container

    International Nuclear Information System (INIS)

    Kurosawa, Masahiko.

    1993-01-01

    The present invention comprises an injection means for adding radioactive materials to coolants in a container cooler, a gamma ray amplitude analyzer connected to coolant pipelines and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to a drain water sump and a means for recording/transferring the data of the result of the measurement, a gamma ray amplitude analyzer connected to various kinds of pipelines and a means for recording/transferring the data of the result of the measurement, and a data processing means for comparing and analyzing the measured data of each of the gamma ray amplitude analyzers inputted from each of date recording/transferring means. The gamma ray amplitude analysis for each of the pipelines and drain water sump are conducted at an appropriate frequency, and the measured data are compared and analyzed, to improve the detection accuracy for a trace amount of leakage from each of the pressure pipelines and the container cooler coolant pipelines, thereby enabling to specify the pipeline having leakage. Maintenance efficiency is improved, and severe rupture accident in each of pressure pipelines is prevented previously. (N.H.)

  18. Calculation of transformers leakage reactance using electromagnetic energy technique

    International Nuclear Information System (INIS)

    Feiz, J.; Mohseni, H.; Sabet Marzooghi, S.; Naderian Jahromi, A.

    2004-01-01

    Determination of transformer leakage reactance using magnetic cores has long been an area of interest to engineers involved in the design of power and distribution transformers. This is required for predicting the performance of transformers before actual assembly of the transformers. In this paper a closed form solution technique applicable to the leakage reactance calculations for transformers is presented. An emphasis is on the development of a simple method to calculate the leakage reactance of the distribution transformers and smaller transformers. Energy technique procedure for computing the leakage reactances in distribution transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using test. This paper presents a novel technique for calculation of the leakage inductance in different parts of the transformer using the electromagnetic stored energy

  19. Indocyanine green staining facilitates detection of bleb leakage during trabeculectomy.

    Science.gov (United States)

    Okazaki, Teruhiko; Kiuchi, Takahiro; Kawana, Keisuke; Oshika, Tetsuro

    2007-03-01

    To report a new technique to visualize bleb leakage using indocyanine green (ICG) staining during trabeculectomy. The ICG solution was widely applied over the filtering bleb including the conjunctival wound before completion of trabeculectomy. This procedure was performed in 48 eyes of 44 consecutive patients undergoing trabeculectomy between December 2004 and October 2005. Without staining, bleb leakage was not identified by the direct observation under the operating microscope. ICG staining clearly visualized aqueous leakage from the bleb in 5 eyes (10.4%). The bleb leakage in these eyes was easily repaired with 10-0 nylon sutures, and no eyes, including these 5 cases, showed bleb leakage after surgery. There were no intraoperative and postoperative complications related to ICG application. The application of ICG during trabeculectomy is a simple and useful technique to facilitate detection and repair of the bleb leakage.

  20. Device for preventing leakage of coolant in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kobayashi, Yukio; Sekiguchi, Mamoru; Yoshida, Hideo.

    1975-01-01

    Object: To prevent leakage of coolant from between lower tie plate and channel box without causing deformation of the channel box and also without the possibility of disturbing the installation and removal of the box by the provision of a thin plate provided with leakage holes for the lower tie plate. Structure: Static water pressure within the lower tie plate is adapted to act upon the bear side of a flat plate for leakage prevention through leakage holes formed in the tie plate, thus urging the flat plate against the channel box inner surface. Meanwhile, static water pressure having been led through the leakage holes in the flat plate is adapted to press the flat plate in the vertical direction, thus urging the flat plate against the channel box inner surface and thereby preventing leakage of the coolant through a gap between the channel box and lower tie plate. (Yoshino, Y.)

  1. Radiologic assessment of spinal CSF leakage in spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Han, Chang Jin; Kim, Ji Hyung; Kim, Jang Sung; Kim, Sun Yong; Suh, Jung Ho

    1999-01-01

    To assess the usefulness of imaging modalities in the detection of spinal CSF leakage in spontaneous intracranial hypotension. Fifteen patients who complained of postural headache without any preceding cause showed typical brain MR findings of intracranial hypotension, including radiologically confirmed CSF leakage. All fifteen underwent brain MRI and radionuclide cisternography. CT myelography was performed in eight patients and spinal MRI in six. Medical records, imaging findings and the incidence of spinal CSF leakage during each modality were retrospectively reviewed. CSF leakage was most common at the cervicothoracic junction, where in seven of 15 cases it was seen on radionuclide cisternography as increased focal paraspinal activity. Leakage was noted at the mid-tho-racic level in three patients, at the upper thoracic level in two, and at the cervical and lumbar levels in the remaining two. In two patients multiple CSF leaks were noted, and in all, early radioactive accumulation in the bladder was visualized. CT myelography revealed extrathecal and paraspinal contrast leakage in three of eight patients, and among those who underwent spinal MRI, dural enhancement was observed at the site of CSF leakage in all six, abnormal CSF signal in the neural foramen in one, and epidural CSF collection in one. Radionuclide cisternography is a useful method for the detection of CSF leakage in spontaneous intracranial hypotension. CT myelography and spinal MRI help determine the precise location of leakage

  2. Particle and radiation leakage importance: definition, analysis, and interpretation

    International Nuclear Information System (INIS)

    Cacuci, D.G.; Wagschal, J.J.; Yaari, A.

    1982-01-01

    The concept of leakage importance function has been introduced and analyzed for physical systems governed by the Boltzmann transport equation. This leakage importance function represents a measure of the relative importance of source particles located at every point in phase space in contributing to the leakage and provides insight regarding the specific physical process that leads to leakage. The equation satisfied by the leakage importance function has been derived by using adjoint operators. It has been shown that procedures that are customarily used to derive an equation obeyed by an importance function suitable for an integral parameter such as a detector response or an eigenvalue lead to difficulties when directly applied to derive an equation obeyed by the leakage importance function. This is because, although leakage is also an integral parameter (i.e., a functional of the forward flux density), leakage is expressed in terms of a surface integral rather than in terms of volume integrals such as those appearing in expressions of detector responses or eigenvalues. Therefore, a procedure that departs from the customary course has been devised to derive the equation satisfied by the leakage importance function

  3. Radionuclide diagnosis of pulmonary capillary protein leakage

    International Nuclear Information System (INIS)

    Creutzig, H.; Sturm, J.A.; Schober, O.; Nerlich, M.L.; Kant, C.J.; Medizinische Hochschule Hannover

    1984-01-01

    Pulmonary extravascular albumin extra-vasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques. (orig.) [de

  4. Fluid leakage near the percolation threshold

    Science.gov (United States)

    Dapp, Wolf B.; Müser, Martin H.

    2016-02-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal—applying common assumptions of elasticity, contact mechanics, and fluid dynamics—show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again.

  5. Anomaly detection using magnetic flux leakage technology

    Energy Technology Data Exchange (ETDEWEB)

    Rempel, Raymond G. [BJ Pipeline Inspection Services, Alberta (Canada)

    2005-07-01

    There are many aspects to properly assessing the integrity of a pipeline. In-line-Inspection (ILI) tools, in particular those that employ the advanced use of Magnetic Flux Leakage (MFL) technology, provide a valuable means of achieving required up-to-date knowledge of a pipeline. More prevalent use of High Resolution MFL In-Line-Inspection tools is growing the knowledge base that leads to more reliable and accurate identification of anomalies in a pipeline, thus, minimizing the need for expensive verification excavations. Accurate assessment of pipeline anomalies can improve the decision making process within an Integrity Management Program and excavation programs can then focus on required repairs instead of calibration or exploratory digs. Utilizing the information from an MFL ILI inspection is not only cost effective but, as well, can also prove to be an extremely valuable building block of a Pipeline Integrity Management Program. (author)

  6. Leakages and pressure relation: an experimental research

    Directory of Open Access Journals (Sweden)

    F. De Paola

    2012-11-01

    Full Text Available Leaks in water systems are presently a frequent and increasing event that involves cost increase and poor service, not compliant to quality standards and modern management criteria. The most recent data available in Italy, resumed into the report issued by Control Committee for Water Resources Use (CONVIRI, shows leakages with an average value of 37%. It is therefore important, for maintenance perspective, to investigate occurrence and evolution of water leaks and the analytical link between leaks Qp and network pressure P, for a reliable calibration of water networks quali-quantitative simulation models. The present work reports the first results of an experimental campaign started at Laboratory of Hydraulics of Department of Hydraulics, Geotechnical and Environmental Engineering of University of Naples Federico II in order to analyze the features of Qp(P relation, which are compared with other results issued in literature.

  7. Potential gonadal dose from leakage radiation?

    International Nuclear Information System (INIS)

    Nicholson, R.A.

    1995-01-01

    The author draws attention to the potential dangers of leakage radiation from mobile image intensifier units, and points out that during interventional urological procedures, radiation from below the urologist's knees may irradiate male gonads without being intercepted by protective aprons. Results are presented for a Shimatzu WHA mobile II, phantom doses being measured with an ionization chamber. Dose rates measured in the male gonad position were compared with rates at waist level behind a 0.35 mm lead equivalent shielding and dose rates at collar level outside the lead apron. Results are also presented of a study on the effect on gonad dose of a) adding 0.7 mm lead shielding to the tube housing and b) adding 0.7 mm lead and removing the spacer cone to reduce scatter. Results show that it is possible for gonad doses to be comparable with those assumed for the eyes, rather than the body. (Author)

  8. Acoustic emission generated by fluid leakage

    International Nuclear Information System (INIS)

    Kim, H.C.

    1987-01-01

    The noise generated by the leaking saturated steam and subcooled water form various sizes of hole has been measured as function of leak rate and stagnation pressure. Acoustic emission (proportinal to root mean sguare voltage) is shown to be proportional to the leak rate and stagnation pressure. A transition of acoustic emission power is observed at the stagnation pressure 0.185 MPa associated with the transition to the critical flow state. Substantially higher acoustic emission power generated by the subcooled water leakage is attributed to the flashing source involving the phase transformation and volume expansion. The relative amplitude of noise spectrum becomes more spiky as the leak rate and stagnation pressure increased. (Author)

  9. Biomembrane Permeabilization: Statistics of Individual Leakage Events Harmonize the Interpretation of Vesicle Leakage.

    Science.gov (United States)

    Braun, Stefan; Pokorná, Šárka; Šachl, Radek; Hof, Martin; Heerklotz, Heiko; Hoernke, Maria

    2018-01-23

    The mode of action of membrane-active molecules, such as antimicrobial, anticancer, cell penetrating, and fusion peptides and their synthetic mimics, transfection agents, drug permeation enhancers, and biological signaling molecules (e.g., quorum sensing), involves either the general or local destabilization of the target membrane or the formation of defined, rather stable pores. Some effects aim at killing the cell, while others need to be limited in space and time to avoid serious damage. Biological tests reveal translocation of compounds and cell death but do not provide a detailed, mechanistic, and quantitative understanding of the modes of action and their molecular basis. Model membrane studies of membrane leakage have been used for decades to tackle this issue, but their interpretation in terms of biology has remained challenging and often quite limited. Here we compare two recent, powerful protocols to study model membrane leakage: the microscopic detection of dye influx into giant liposomes and time-correlated single photon counting experiments to characterize dye efflux from large unilamellar vesicles. A statistical treatment of both data sets does not only harmonize apparent discrepancies but also makes us aware of principal issues that have been confusing the interpretation of model membrane leakage data so far. Moreover, our study reveals a fundamental difference between nano- and microscale systems that needs to be taken into account when conclusions about microscale objects, such as cells, are drawn from nanoscale models.

  10. Leakage Inductance Calculation for Planar Transformers with a Magnetic Shunt

    DEFF Research Database (Denmark)

    Jun, Zhang; Ouyang, Ziwei; Duffy, M. C.

    2013-01-01

    The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer...

  11. Macrophage migration inhibitory factor induces vascular leakage via autophagy

    Directory of Open Access Journals (Sweden)

    Hong-Ru Chen

    2015-01-01

    Full Text Available Vascular leakage is an important feature of acute inflammatory shock, which currently has no effective treatment. Macrophage migration inhibitory factor (MIF is a pro-inflammatory cytokine that can induce vascular leakage and plays an important role in the pathogenesis of shock. However, the mechanism of MIF-induced vascular leakage is still unclear. In this study, using recombinant MIF (rMIF, we demonstrated that MIF induced disorganization and degradation of junction proteins and increased the permeability of human endothelial cells in vitro. Western blotting analysis showed that rMIF treatment induced LC3 conversion and p62 degradation. Inhibition of autophagy with a PI3K inhibitor (3-MA, a ROS scavenger (NAC or autophagosomal-lysosomal fusion inhibitors (bafilomycin A1 and chloroquine rescued rMIF-induced vascular leakage, suggesting that autophagy mediates MIF-induced vascular leakage. The potential involvement of other signaling pathways was also studied using different inhibitors, and the results suggested that MIF-induced vascular leakage may occur through the ERK pathway. In conclusion, we showed that MIF triggered autophagic degradation of endothelial cells, resulting in vascular leakage. Inhibition of MIF-induced autophagy may provide therapeutic targets against vascular leakage in inflammatory shock.

  12. Theory and Practice of a Leakage Resilient Masking Scheme

    DEFF Research Database (Denmark)

    Balasch, Josep; Faust, Sebastian; Gierlichs, Benedikt

    2012-01-01

    A recent trend in cryptography is to formally prove the leakage resilience of cryptographic implementations – that is, one formally shows that a scheme remains provably secure even in the presence of side channel leakage. Although many of the proposed schemes are secure in a surprisingly strong m...

  13. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  14. Leakage-Resilient Cryptography from the Inner-Product Extractor

    DEFF Research Database (Denmark)

    Dziembowski, Stefan; Faust, Sebastian

    2011-01-01

    We present a generic method to secure various widely-used cryptosystems against arbitrary side-channel leakage, as long as the leakage adheres three restrictions: first, it is bounded per observation but in total can be arbitrary large. Second, memory parts leak independently, and, third, the ran...

  15. Anastomotic leakage after anterior resection for rectal cancer

    DEFF Research Database (Denmark)

    Bulow, S.

    2008-01-01

    On the basis of the literature about anastomotic leakage after anterior resection for rectal cancer a review is presented of the frequency, potential risk factors and consequences of leakage. The risk factors are evaluated according to the level of scientific evidence of the individual background...

  16. On the scaling of gas leakage from static seals

    International Nuclear Information System (INIS)

    Chivers, T.C.; Hunt, R.P.

    1977-01-01

    The interaction between gas leakage from static seals and eight potential variables is discussed. From a consideration of the interaction of these various parameters and the mechanical design of the seal system the importance of correctly interpreting leakage data is demonstrated. Given a situation where model experiments are necessary, this document forms a basis for the definition and interpretation of a test programme. (author)

  17. A review on leakage rate tests for containment isolation systems

    International Nuclear Information System (INIS)

    Kim, In Goo; Kim, Hho Jung

    1992-01-01

    Wide experiences in operating containment isolation systems have been accumulated in Korea since 1978. Hence, it becomes necessary to review the operating data in order to confirm the integrity of containments with about 50 reactor-years of experience and to establish the future direction to the containment test program. The objectives of present work are to collect, consolidate and assess the leakage rate data, and then to find out dominant leakage paths and factors affecting integrated leakage rate test. General trends of overall leakage show that more careful surveillance during pre-operational test can reduce the containment leakage. Dominant leakage paths are found to be through air locks and large-sized valves, such as butterfly valves of purge lines, so that weighted surveillance and inspection on these dominant leakage paths can considerably reduce the containment leakage. The atmosphere stabilization are found to be the most important to obtain the reliable result. In order to get well stabilized atmosphere, temperature and flow rate of compressed air should be kept constant and it is preferable not to operate fan cooler during pressurizing the containment for test

  18. Hunting the unknown: White-box database leakage detection

    NARCIS (Netherlands)

    Costante, E.; Hartog, den J.I.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.; Atluri, V.; Pernul, G.

    2014-01-01

    Data leakage causes significant losses and privacy breaches worldwide. In this paper we present a white-box data leakage detection system to spot anomalies in database transactions. We argue that our approach represents a major leap forward w.r.t. previous work because: i) it significantly decreases

  19. Determination of Unidentified Leakage Using a Kalman Smoother

    International Nuclear Information System (INIS)

    Jang, Soek Bo; Heo, Gyunyoung; Ra, Insik; Han, Jeonghyun; Lee, Seon Woo

    2008-01-01

    Since the safety significance of leaks from the RCS can widely vary depending on the source of the leak as well as the leak rate, the detection of the leakage is an important issue. The leakage is classified into 1) identified leakage which is defined as leakage into closed systems such as pump seal or valve packing leaks that can be captured, and 2) unidentified leakage which is all other leakage. The unidentified leakage is typically determined by the RCS inventory balance method which is based on NUREG-1107. Since the accuracy of leak rate calculation is dependent of the plant operating condition, the change in the RCS temperature, inventory, and the transient operating condition should be avoided during the measurement period. Nevertheless, the operation of the makeup of the borated water into the RCS and the diversion of the inventory to the outside of the RCS boundary makes it difficult to maintain the plant stable over an hour. Due to the large fluctuation of the calculated leak rate, it is sometimes hard to know the trend of the leakage as well as the instantaneous leak rate. Any fluctuation of operating conditions can results in unreliable leak rate. This study proposes a new way of determining the unidentified leak rate using a Kalman filter and smoother technique. The proposed algorithm enhances the accuracy of the leak rate calculation not only for the steady state operations but also for transients in a well timed manner

  20. Failure analysis of leakage current in plastic encapsulated packages

    International Nuclear Information System (INIS)

    Hu, S.J.; Cheang, F.T.

    1989-12-01

    Plastic encapsulated packages exhibit high leakage current after a few hundred hours steam pressure pot test. The present study investigates two possible sources of leakage current, the mold compound and the lead frame tape used for taping the lead frame fingers. The results of the study indicate that the leakage current is independent of the frame and is not caused by the mold compound. The data further indicates that it is the ionic contents and acrylic-based adhesive layer of the lead frame tapes which cause the leakage current. To eliminate the leakage current, lead frame tape with low ionic contents and non acrylic-based adhesive should be used. (author). 1 fig., 2 tabs, 3 graphs

  1. An objective comparison of leakage between commonly used earplugs.

    Science.gov (United States)

    Alt, Jeremiah A; Collins, William O

    2012-01-01

    We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P leakage when compared with the cotton ball coated with petroleum jelly (P leakage compared with the customized plug (P leakage than the cotton plug (P leakage rate (f(4,45) = 94 [P water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. PERFORMANCE OF LEAKAGE POWER MINIMIZATION TECHNIQUE FOR CMOS VLSI TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    T. Tharaneeswaran

    2012-06-01

    Full Text Available Leakage power of CMOS VLSI Technology is a great concern. To reduce leakage power in CMOS circuits, a Leakage Power Minimiza-tion Technique (LPMT is implemented in this paper. Leakage cur-rents are monitored and compared. The Comparator kicks the charge pump to give body voltage (Vbody. Simulations of these circuits are done using TSMC 0.35µm technology with various operating temper-atures. Current steering Digital-to-Analog Converter (CSDAC is used as test core to validate the idea. The Test core (eg.8-bit CSDAC had power consumption of 347.63 mW. LPMT circuit alone consumes power of 6.3405 mW. This technique results in reduction of leakage power of 8-bit CSDAC by 5.51mW and increases the reliability of test core. Mentor Graphics ELDO and EZ-wave are used for simulations.

  3. Leakage current characteristics of the multiple metal alloy nanodot memory

    International Nuclear Information System (INIS)

    Lee, Gae Hun; Lee, Jung Min; Yang, Hyung Jun; Song, Yun Heub; Bea, Ji Chel; Tanaka, Tetsu

    2010-01-01

    The leakage current characteristics of a multiple metal alloy nanodot device for a nonvolatile random access memory using FePt materials are investigated. Several annealing conditions are evaluated and optimized to suppress the leakage current and to better the memory characterisctics. This work confirmed that the annealing condition of 700 .deg. C in a high vacuum ambience (under 1 x 10 -5 Pa) simultaneously provided good cell characteristics from a high dot density of over 1 x 10 13 /cm 2 and a low leakage current. In addition, a smaller nanodot diameter was found to give a lower leakage current for the multiple nanodot memory. Finally, for the proposed annealing condition, the quadruple FePt multiple nanodot memory with a 2-nm dot diameter provided good leakage current characteristics, showing a threshold voltage shift of under 5% at an initial retention stage of 1000 sec.

  4. Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

    Directory of Open Access Journals (Sweden)

    Bing Luo

    2012-07-01

    Full Text Available In this paper, an artificial pollution test is carried out to study the leakage current of porcelain insulators. Fractal theory is adopted to extract the characteristics hidden in leakage current waveforms. Fractal dimensions of the leakage current for the security, forecast and danger zones are analyzed under four types of degrees of contamination. The mean value and the standard deviation of the fractal dimension in the forecast zone are calculated to characterize the differences. The analysis reveals large differences in the fractal dimension of leakage current under different contamination discharge stages and degrees. The experimental and calculation results suggest that the fractal dimension of a leakage current waveform can be used as a new indicator of the discharge process and contamination degree of insulators. The results provide new methods and valid indicators for forecasting contamination flashovers.

  5. Ship cabin leakage alarm based on ARM SCM

    Science.gov (United States)

    Qu, Liyan

    2018-03-01

    If there is a leakage in the cabin of a sailing ship, it is a major accident that threatens the personnel and property of the ship. If we can’t take timely measures, there will be a devastating disaster. In order to judge the leakage of the cabin, it is necessary to set up a leakage alarm system, so as to achieve the purpose of detecting and alarming the leakage of the cabin, and avoid the occurrence of accidents. This paper discusses the design of ship cabin leakage alarm system based on ARM SCM. In order to ensure the stability and precision of the product, the hardware design of the alarm system is carried out, such as circuit design, software design, the programming of SCM, the software programming of upper computer, etc. It is hoped that it can be of reference value to interested readers.

  6. Distributed public key schemes secure against continual leakage

    DEFF Research Database (Denmark)

    Akavia, Adi; Goldwasser, Shafi; Hazay, Carmit

    2012-01-01

    -secure against continual memory leakage. Our DPKE scheme also implies a secure storage system on leaky devices, where a value s can be secretely stored on devices that continually leak information about their internal state to an external attacker. The devices go through a periodic refresh protocol......In this work we study distributed public key schemes secure against continual memory leakage. The secret key will be shared among two computing devices communicating over a public channel, and the decryption operation will be computed by a simple 2-party protocol between the devices. Similarly...... against continual memory leakage, under the Bilinear Decisional Diffie-Hellman and $2$-linear assumptions. Our schemes have the following properties: 1. Our DPKE and DIBE schemes tolerate leakage at all times, including during refresh. During refresh the tolerated leakage is a (1/2-o (1),1)-fraction...

  7. Leakage experiences with 1 MW steam generator

    International Nuclear Information System (INIS)

    Kanamori, A.; Kawara, M.; Sano, A.

    1975-01-01

    An 1 MW steam generator was tested from October, 1971 and completed with the first series of experiments by May, 1972 after 3600 hours of operation. During these tests, unextraordinary heat absorption was experienced in the downcomer region, which led to shortage of heat transfer area to attain the rated steam temperature and to one of the reasons of flow instabilities. The steam generator was disassembled to get test pieces for structure as well as material examinations and then it was reassembled to proceed the second series of tests. Before it was done, a modification was provided to insulate the downcomer region by putting a gas space around the downcomer tube. The gas space was provided by a dual tube and spacers were welded on the inner tube and an end plate was welded on upper parts between the two to seal the gap by means of fillet welding. After the modified steam generator was put into operation, water happened to leak into a sodium side two times through these additional welding spots for the gas insulation. This paper presents operating conditions and behaviors of monitors at the time of the leakages, identifications of leaked spots, an evaluation of causes and a treatment or a precaution for them

  8. Radiation leakage from linac electron applicator assembly

    International Nuclear Information System (INIS)

    Keys, R.A.; Purdy, J.A.

    1984-01-01

    The electron beam applicator system currently in use on the linear accelerator is constructed of light-weight fiberglass and aluminum. With an applicator in place on the accelerator, the photon collimator jaws are automatically set several centimeters greater than the electron field size projected at the patient's surface. To ensure that no regions of high dose levels exist outside the useful beam, ionization and film measurements were made to quantitate the amount of leakage radiation through the 10 cm x 10 cm and 25 cm x 25 cm applicators. In most regions, the ionization levels at the patient's surface were below 5% of the central axis dose. In one area for the 25 cm applicator, the percentage ionization was 8.5%, which could be reduced by the addition of a small piece of 1/8 inch thick lead. However, ionization levels on the outside surface of the applicator were found to be considerably higher at certain locations for the 25 cm applicator. Results for 6, 9, 12 and 20 MeV electrons are reported here

  9. Leakage pattern of linear accelerator treatment heads from multiple vendors

    International Nuclear Information System (INIS)

    Lonski, P.R.; Taylor, M.L.; Franich, R.D.; Harty, P.; Clements, N.; Kron, T.

    2011-01-01

    Full text: Patient life expectancy post-radiotherapy is becoming longer. Therefore, secondary cancers caused by radiotherapy treatment have more time to develop. Increasing attention is being given to out-of-field dose resulting from scatter and accelerator head leakage. Dose leakage from equivalent positions on Varian600C, Varian21-X, Siemens Primus and Elekta Synergy-II linacs were measured with TLD 1 00 H dosimeter chips and compared. Treatment parameters such as field size and beam energy were altered. Leakage doses are presented as a percentage of the dose to isocentre (5 Gy). Results illustrate significant variations in leakage dose between linac models where no model emits consistently lower amounts of radiation leakage for all treatment parameters. Results are shown below. Leakage through the collimator assembly in different units is varying as a function of location and unit design by more than a factor of 10. Differences are more pronounced in comparing Varian or Elekta models, which are fitted with an additional collimator separate from the MLC leaves, to the Siemens model, which uses MLC leaves as its only secondary collimator. Further measurements are currently being taken at the patient plane with a directional detector system to determine the spatial distribution of high leakage sources.

  10. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  11. Developement of leakage localization technique by using acoustic signal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. H.; Jeon, J. H.; Seo, D. H.; Kim, K. W. [KAIST, Daejeon (Korea, Republic of)

    2010-07-15

    The objective of this research is to develop a leakage monitoring system for pipelines or valves in the secondary water system of a nuclear power plant. The system aims to detect the existence of leakage and to estimate the leak location, especially by utilizing the noise generated from the leak. It is safe, precise real-time alert system compared with the previous monitoring methods and tools such as the visual test and the thermal imaging camera. When there exists leakage in the pipeline or valves of nuclear power plant, the noise due to gas flow is radiated through leak region. That is, the secondary water system with leakage generates different noise from the system without leakage. This motivates us to measure and analyze the noise generated from the secondary water system, so as firstly to detect the existence of leakage, and secondly to estimate the leak location by using the noise source identification technique such as beamforming and acoustic holography. Especially the beamforming method models the signal from the noise source to estimate the location of source. Therefore, it is necessary to model the noise due to leakage which is dependent upon parameters. In the process of leak localization, the reflected wave due to interior walls and the measurement noise should be removed for the precise estimation. Therefore, we attempt to characterize the reflected wave and the measurement noise by modeling the interior sound field, thus to remove them and to localize the leak location with high precision

  12. Detection device for pipeway water leakage in building

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1988-01-01

    Purpose: To rapidly detect pipeway leakage at predetermined areas over a wide range in a building. Constitution: If flooding should occur in a power plant building and left as it is, emergency core cooling system, as well as auxiliary equipments and electrical equipments of the system are flooded to make the safety shutdown of the plant impossible. The present invention copes with such a risk. That is, an inlet flow meter and as exit flow meter are disposed to the inlet and the exit of pipeways disposed in a predetermined region in the building and a flow rate difference detector between them is disposed. In this way, pipeway leakage is detected by detecting the flow rate difference between the inlet flow rate and the exit flow rate of the pipeway in the predetermined region. According to the present invention, if a pipeway in a predetermined region is raptured to cause water leakage, the pipeway leakage can rapidly be detected depending on the flow rate difference between the inlet flow rate and the exit flow rate. Further, the water leakage over the entire the predetermined region can be detected rapidly as compared with the conventional case of detecting the leakage at a restricted portion where the leakage detector is disposed. (Kamimura, M.)

  13. Junction leakage measurements with micro four-point probes

    DEFF Research Database (Denmark)

    Lin, Rong; Petersen, Dirch Hjorth; Wang, Fei

    2012-01-01

    We present a new, preparation-free method for measuring the leakage current density on ultra-shallow junctions. The junction leakage is found by making a series of four-point sheet resistance measurements on blanket wafers with variable electrode spacings. The leakage current density is calculated...... using a fit of the measured four-point resistances to an analytical two-sheet model. The validity of the approximation involved in the two-sheet model is verified by a comparison to finite element model calculations....

  14. Theory and Application of Magnetic Flux Leakage Pipeline Detection.

    Science.gov (United States)

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-12-10

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted.

  15. Copper ion as a new leakage tracer.

    Science.gov (United States)

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  16. Toward Understanding Tip Leakage Flows in Small Compressor Cores Including Stator Leakage Flow

    Science.gov (United States)

    Berdanier, Reid A.; Key, Nicole L.

    2017-01-01

    The focus of this work was to provide additional data to supplement the work reported in NASA/CR-2015-218868 (Berdanier and Key, 2015b). The aim of that project was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue University with a specific focus on analyzing the multistage effects resulting from the tip leakage flow. Three separate rotor tip clearances were studied with nominal tip clearance gaps of 1.5 percent, 3.0 percent, and 4.0 percent based on a constant annulus height. Overall compressor performance was previously investigated at four corrected speedlines (100 percent, 90 percent, 80 percent, and 68 percent) for each of the three tip clearance configurations. This study extends the previously published results to include detailed steady and time-resolved pressure data at two loading conditions, nominal loading (NL) and high loading (HL), on the 100 percent corrected speedline for the intermediate clearance level (3.0 percent). Steady detailed radial traverses of total pressure at the exit of each stator row are supported by flow visualization techniques to identify regions of flow recirculation and separation. Furthermore, detailed radial traverses of time-resolved total pressures at the exit of each rotor row have been measured with a fast-response pressure probe. These data were combined with existing three-component velocity measurements to identify a novel technique for calculating blockage in a multistage compressor. Time-resolved static pressure measurements have been collected over the rotor tips for all rotors with each of the three tip clearance configurations for up to five loading conditions along the 100 percent corrected speedline using fast-response piezoresistive pressure sensors. These time-resolved static pressure measurements reveal new knowledge about the

  17. Leakage potential through mechanical penetrations in a severe accident environment

    International Nuclear Information System (INIS)

    Koenig, L.N.

    1986-01-01

    This paper reviews the findings of an ongoing program, Integrity of Containment Penetrations Under Severe Accident Loads. The program is concerned with the leakage modes as well as the magnitude of leakage through mechanical penetrations in a containment building subject to a severe accident. Seal and gasket tests are used to evaluate the effect of radiation aging, thermal aging, seal geometry, and seal squeeze on seals and gaskets subjected to a hypothesized severe accident. The effects on leakage of the structural response of equipment hatches, personnel airlocks, and drywell heads subjected to severe accident pressures are studied by experiments and analyses. The data gathered during this program will be used to develop methodologies for predicting leakage

  18. N13 - based reactor coolant pressure boundary leakage system

    International Nuclear Information System (INIS)

    Dissing, E.; Marbaeck, L.; Sandell, S.; Svansson, L.

    1980-05-01

    A system for the monitoring of leakage of coolant from the reactor coolant pressure boundary and auxiliary systems to the reactor containment, based on the detection of the N13 content in the atmosphere, has been tested. N13 is produced from the oxyegen of the reactor water via the recoil photon nuclear process H1 + 016 + He4. The generation of N13 is therefore independent of fuel element leakage and of the corrosion product content in the water. In the US AEC regulatory guide 1.45 has a leakage increase of 4 liter/ min been suggested as the response limit. The experiments carried out in Ringhals indicate, that with the accomplishment of minor improvements in the installation, a 4 liter/min leakage to the containment will give rise to a signal with a random error range of +- 0.25 liter/min, 99.7 % confidence level. (author)

  19. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Moreover, the proposed inverter can also eliminate the well-known double line frequency pulsating power....... The mechanism of leakage current suppression and the closed-loop control of pulsating power decoupling are discussed in the paper in details. A 500 W prototype was also built and tested in the laboratory, and both simulation and experimental results are finally presented to show the excellent performance...

  20. Competitiveness and carbon leakages in industry under asymmetric climate policy

    International Nuclear Information System (INIS)

    Demailly, D.

    2008-02-01

    This research aims at studying how to predict competitiveness loss for an industry submitted to an asymmetric carbon constraint, and carbon leakages, whether high losses and important leakages might be feared, and which policies can be used to mitigate these losses and escapes. The author analyses and comments the content of four articles dealing with: the impact on competitiveness, revenue distribution and economic efficiency of a change in the allocation rules for EU greenhouse gas allowances; the relationship between allocation of CO 2 allowances and competitiveness in the case of the European iron and steel industry; CO 2 abatement, competitiveness and leakage in the European cement industry under EU ETS; and leakage from climate policies and border tax adjustment (lessons from a geographic model of the cement industry). Then, the author combines several approaches to study the cement and steel industries

  1. Fractal modeling of fluidic leakage through metal sealing surfaces

    Science.gov (United States)

    Zhang, Qiang; Chen, Xiaoqian; Huang, Yiyong; Chen, Yong

    2018-04-01

    This paper investigates the fluidic leak rate through metal sealing surfaces by developing fractal models for the contact process and leakage process. An improved model is established to describe the seal-contact interface of two metal rough surface. The contact model divides the deformed regions by classifying the asperities of different characteristic lengths into the elastic, elastic-plastic and plastic regimes. Using the improved contact model, the leakage channel under the contact surface is mathematically modeled based on the fractal theory. The leakage model obtains the leak rate using the fluid transport theory in porous media, considering that the pores-forming percolation channels can be treated as a combination of filled tortuous capillaries. The effects of fractal structure, surface material and gasket size on the contact process and leakage process are analyzed through numerical simulations for sealed ring gaskets.

  2. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... completion of the operation the patients were randomized in two groups with and without a transanal stent. RESULTS: A clinically significant leakage was diagnosed in 25 patients (13%). No significant difference was found 17 of 98 patients with a stent and 8 of 96 without (P = 0.09), or in 9 of 44 ileostomy...... patients with a stent and in 3 of 45 without (P = 0.07). Several leaks over a short time led to an interim analysis after inclusion of 194 of 448 planned patients. The analysis showed no significant protective effect of the stent, and more leakages in the stent group, although not statistically significant...

  3. Prediction of leakage in the fixed mechanical seal

    Directory of Open Access Journals (Sweden)

    Asheichik Anatoly A.

    2017-01-01

    Full Text Available The questions of influence of the shape of contact surfaces on leakages through rubber seals in fixed connection of subassemblies are considered in the article. It is known from practice of operation of seals of various designs that the shape of contact surfaces and consequently also the shape of diagram of stresses in a contact zone considerably influences on value of leaks Linking leakage magnitude and distribution of contact stresses enables, firstly, more precisely calculate the amount of leakage for existing seals, and, secondly, to optimize the shape of the seals in their design in each case. As the result of experimental studies on the introduction of the rubber gasket ring fixed indenters different profiles found that by optimizing the shape of the indenter magnitude of leakage can be reduced by 10 times.

  4. Magnetic leakage shield of septum magnet for SPring-8 synchrotron

    International Nuclear Information System (INIS)

    Abe, Hiroshi; Aoki, Tsuyoshi; Fukami, Kenji

    1997-01-01

    This paper describes magnetic field measurements of the prototype septum magnet and countermeasure for reducing the leakage magnetic fields in the incidence and the extraction parts of the SPring-8 synchrotron. We studied and developed 'leakage magnetic shield' on the basis of the tests data got in these measurements. Consequentially, it succeeded in reducing effects of the leakage field to about 50% by installing the shield board in the magnet main body. Then, it was possible to manufacture the magnet which sufficiently held the effect of the leakage field for the electron and positron beam. In this examination, we confirmed the reproduction with the magnetic field distribution of the magnet measured in the manufacturer. We developed and produced of the septum magnets which were carried out determination of the shapes of the magnetic shielding. (author)

  5. Leakage Testing for Different Adhesive Systems and Composites to ...

    African Journals Online (AJOL)

    2015-11-16

    Nov 16, 2015 ... resin composite, the fifth group – two‑stage SE adhesive applied and cavities filled with ... KEYWORDS: Adhesives, composite, evaluation, leakage ... the glass ionomers. ... systems are realized in one or two clinical step(s).[5].

  6. Detecting the leakage source of a reservoir using isotopes.

    Science.gov (United States)

    Yi, Peng; Yang, Jing; Wang, Yongdong; Mugwanezal, Vincent de Paul; Chen, Li; Aldahan, Ala

    2018-07-01

    A good monitoring method is vital for understanding the sources of a water reservoir leakage and planning for effective restoring. Here we present a combination of several tracers ( 222 Rn, oxygen and hydrogen isotopes, anions and temperature) for identification of water leakage sources in the Pushihe pumped storage power station which is in the Liaoning province, China. The results show an average 222 Rn activity of 6843 Bq/m 3 in the leakage water, 3034 Bq/m 3 in the reservoir water, and 41,759 Bq/m 3 in the groundwater. Considering that 222 Rn activity in surface water is typically less than 5000 Bq/m 3 , the low level average 222 Rn activity in the leakage water suggests the reservoir water as the main source of water. Results of the oxygen and hydrogen isotopes show comparable ranges and values in the reservoir and the leakage water samples. However, important contribution of the groundwater (up to 36%) was present in some samples from the bottom and upper parts of the underground powerhouse, while the leakage water from some other parts indicate the reservoir water as the dominant source. The isotopic finding suggests that the reservoir water is the main source of the leakage water which is confirmed by the analysis of anions (nitrate, sulfate, and chloride) in the water samples. The combination of these tracer methods for studying dam water leakage improves the accuracy of identifying the source of leaks and provide a scientific reference for engineering solutions to ensure the dam safety. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Method of detecting leakage in nuclear reactor containment vessel

    International Nuclear Information System (INIS)

    Koba, Akitoshi; Goto, Seiichiro.

    1974-01-01

    Object: To permit accurate and prompt detection of leakage of a radioactive substance. Structure: The rate of change of such factors as radiation dose, temperature and pressure in the containment vessel, and each detected rate of change is compared with a reference value. The running cycle of the condensed drain exhausting pump in a drain collecting tank within a predetermined period is detected, and it is also compared with a reference value. These comparisons determine the absence or presence of leakage. (Kamimura, M.)

  8. LMFBR technology. FFTF cover-gas leakage calculation

    International Nuclear Information System (INIS)

    Deboi, H.

    1974-01-01

    The FFTF LMFBR is intended to have a near zero release of radioactive gases during normal reactor operation with 1% failed fuel. This report presents calculations which provide an approximation of these cover gas leakages. Data from ongoing static and dynamic seal leak tests at AI are utilized. Leakage through both elastomeric and metallic seals in all sub-assemblies and penetrations comprising the reactor cover gas containment during reactor operation system are included

  9. An alternative treatment for anastomotic leakage after oesophageal resection

    DEFF Research Database (Denmark)

    Damm, P; Hoffmann, J.

    1988-01-01

    An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity.......An alternative non-operative method for treatment for anastomotic leakage after oesophageal resection is presented. A mediastinal abscess cavity was drained by an ordinary nasogastric tube introduced via the nose through the anastomotic defect and into the cavity....

  10. From Tree Structure to Interactive Network:A Preliminary Study on Transit-Oriented Spatial Development Patterns of Village-Town Communities

    Institute of Scientific and Technical Information of China (English)

    Jinyan; WANG; Shuhua; HE; Fang; QIAN

    2014-01-01

    Based on the relatively developed highway and road network in China’s eastern coastal provinces, the public transit-oriented development model(TOD) for village-town communities aims to create a network connecting the urban and rural public transportation system and the public service system, by selectively constructing 'urban-type' communities with bus stops, thus promoting the mobility of urban and rural factors and to optimize the public service system, so as to change the traditional top-down development mode with tree structure. Through the planning practice in Linyi County, Dezhou City, it is found that a TOD-based spatial development mode in village-town communities can provide references for new countryside planning and construction in China in terms of upgrading the urban-rural functional structure, satisfying local demands, optimizing local government decisions, improving the planning mode, etc.

  11. Management and prevention of chylous leakage after laparoscopic lymphadenectomy.

    Science.gov (United States)

    Han, L-P; Zhang, H-M; Abha, H-D; Liu, T; Zhang, X-P

    2014-01-01

    To investigate the development and management of chylous leakage after laparoscopic retroperitoneal lymphadenectomy. From July 2006 to September 2013, 13 cases of chylous leakage after the laparoscopic lymphadenectomy (6 cases of renal cell carcinoma, 4 cases of gastric cancer, 2 cases of ovarian cancer, 1 case of endometrial cancer) were studied to analyze the occurrence, development and management of chylous leakage. In 3 cases (2 cases of renal cell carcinoma, 1 case of gastric cancer) massive amount of milky fluid drainage was be seen after the first two days post operation. Dietary intervention, TPN (total parenteral nutrition), somatostatin therapy, maintenance of continuous drainage helped to successfully manage the condition in about 1 month duration. In the remaining 10 cases, chylous leakage appeared after restoring normal diet. Managed with changes in diet and maintenance of unobstructed drainage, they were cured in about 2 weeks after treatment. There was significant reduction in drain output, ultrasonography did not reveal presence of free fluid collection in abdomen, and the patients were in good condition without signs and symptoms of infections. Chylous leakage is a rare complication of retroperitoneal lymph node dissection. Surgeons should be familiar with laparoscopic techniques, relevant anatomy and be aware of the fact that the effect of CO2 pressure and use of ultrasonic knife to occlude the lymphatic vessel can transiently block the leakage making the surgeon overlook them. Routine placement of indwelling drainage tube, immediate diagnosis, dietary modification, TPN, somatostatin and drainage are the modalities of conservative management.

  12. Field size dependent mapping of medical linear accelerator radiation leakage

    International Nuclear Information System (INIS)

    Vu Bezin, Jérémi; De Vathaire, Florent; Diallo, Ibrahima; Veres, Attila; Lefkopoulos, Dimitri; Chavaudra, Jean; Deutsch, Eric

    2015-01-01

    The purpose of this study was to investigate the suitability of a graphics library based model for the assessment of linear accelerator radiation leakage. Transmission through the shielding elements was evaluated using the build-up factor corrected exponential attenuation law and the contribution from the electron guide was estimated using the approximation of a linear isotropic radioactive source. Model parameters were estimated by a fitting series of thermoluminescent dosimeter leakage measurements, achieved up to 100 cm from the beam central axis along three directions. The distribution of leakage data at the patient plane reflected the architecture of the shielding elements. Thus, the maximum leakage dose was found under the collimator when only one jaw shielded the primary beam and was about 0.08% of the dose at isocentre. Overall, we observe that the main contributor to leakage dose according to our model was the electron beam guide. Concerning the discrepancies between the measurements used to calibrate the model and the calculations from the model, the average difference was about 7%. Finally, graphics library modelling is a readily and suitable way to estimate leakage dose distribution on a personal computer. Such data could be useful for dosimetric evaluations in late effect studies. (paper)

  13. International Market Leakage from China’s Forestry Policies

    Directory of Open Access Journals (Sweden)

    Xin Hu

    2014-11-01

    Full Text Available Carbon leakage can be a problem when seeking to reduce carbon emissions through forest policy. International market leakage is mainly caused by supply and demand imbalances in the timber market. This paper selects China, which is implementing forestry policy changes, as the research object. We begin by offering a brief analysis of China’s forestry policy changes, such as the logging quota and Six Key Forestry Programs to determine whether those policies affect timber supply. Second, through the use of three shock variables, carbon leakage is simulated under different scenarios by the Global Trade Analysis Project (GTAP model. The results reveal that the magnitude of leakage caused by implementing China’s forestry policies is between 79.7% and 88.8% with carbon leakage mainly displaced to Russia, Southeast Asia, and the EU. Two effective scenarios for reducing market leakage are presented: forest tenure reform and fast growing forest projects to improve domestic timber production, and raising tariffs on timber imports to reduce imports.

  14. Leakage localization with an acoustic array that covers a wide area for pipeline leakage monitoring in a closed space

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon Su [Center for Safety Measurements, Division of Metrology for Quality of Life, Korea Research institute of Standards and Science, Daejeon (Korea, Republic of); Jeon, Jong Hoon [Hyundai Heavy Industry Co.,Ltd., Ulsan (Korea, Republic of); Park, Jin Ho [Korea Atomiv Energy Institute, Daejeon (Korea, Republic of)

    2013-10-15

    It is of great importance to localize leakages in complex pipelines for assuring their safety. A sensor array that can detect where leakages occur enables us to monitor a wide area with a relatively low cost. Beam forming is a fast and efficient algorithm to estimate where sources are, but it is generally made use of in free field condition. In practice, however, many pipelines are placed in a closed space for the purpose of safety and maintenance. This leads us to take reflected waves into account to the beam forming for interior leakage localization. Beam power distribution of reflected waves in a closed space is formulated, and spatial average is introduced to suppress the effect of reflected waves. Computer simulations and experiments ensure how the proposed method is effective to localize leakage in a closed space for structural health monitoring.

  15. [Bile leakage after liver resection: A retrospective cohort study].

    Science.gov (United States)

    Menclová, K; Bělina, F; Pudil, J; Langer, D; Ryska, M

    2015-12-01

    Many previous reports have focused on bile leakage after liver resection. Despite the improvements in surgical techniques and perioperative care the incidence of this complication rather keeps increasing. A number of predictive factors have been analyzed. There is still no consensus regarding their influence on the formation of bile leakage. The objective of our analysis was to evaluate the incidence of bile leakage, its impact on mortality and duration of hospitalization at our department. At the same time, we conducted an analysis of known predictive factors. The authors present a retrospective review of the set of 146 patients who underwent liver resection at the Department of Surgery of the 2nd Faculty of Medicine of the Charles University and Central Military Hospital Prague, performed between 20102013. We used the current ISGLS (International Study Group of Liver Surgery) classification to evaluate the bile leakage. The severity of this complication was determined according to the Clavien-Dindo classification system. Statistical significance of the predictive factors was determined using Fishers exact test and Students t-test. The incidence of bile leakage was 21%. According to ISGLS classification the A, B, and C rates were 6.5%, 61.2%, and 32.3%, respectively. The severity of bile leakage according to the Clavien-Dindo classification system - I-II, IIIa, IIIb, IV and V rates were 19.3%, 42%, 9.7%, 9.7%, and 19.3%, respectively. We determined the following predictive factors as statistically significant: surgery for malignancy (pBile leakage significantly prolonged hospitalization time (pbile leakage the perioperative mortality was 23 times higher (pBile leakage is one of the most serious complications of liver surgery. Most of the risk factors are not easily controllable and there is no clear consensus on their influence. Intraoperative leak tests could probably reduce the incidence of bile leakage. In the future, further studies will be required to improve

  16. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  17. Leakage evaluation in the PCV (Primary Containment Vessel) using chemical and radiochemical data

    International Nuclear Information System (INIS)

    Maeda, Katsuji; Nagasawa, Katsumi

    1998-01-01

    Keeping the reliability of nuclear power plant operation, the primary coolant leakage in the PCV is strictly restricted by the Technical Specifications. It is very important to detect an indication of leakage and estimate the source of leakage to provide countermeasures. Usually the indication of leakage will be detected by increase of drain flow in the PCV sump. There are some possibilities of leakage sources in the PCV, such as reactor water, main steam, condensate, feedwater and closed cooling water. The leakage source contain different chemical and radiochemical species. This means that the leakage source can be presumed and detected by using chemical information from the PCV atmosphere and sump water. To detect the leakage indication and the source quickly and exactly, the PCV Leakage Detection Expert System has been developed. This paper describes how to evaluate the leakage indication and source in the PCV by using chemical and radiochemical data. (author)

  18. Suppression and control of leakage field in electromagnetic helical microwiggler

    Energy Technology Data Exchange (ETDEWEB)

    Ohigashi, N. [Kansai Univ., Osaka (Japan); Tsunawaki, Y. [Osaka Sangyo Univ. (Japan); Imasaki, K. [Institute for Laser Technology, Osaka (Japan)] [and others

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  19. Report on the water leakage from instrumentation pipe in JMTR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-03-01

    On December 10, 2002, the leakage was found at the pressure instrumentation pipe attached to the exit pipe of No.1 charging pump of the purification system of a primary cooling system at JMTR in the Oarai Research establishment, JAERI. The Investigation Committee for Water Leakage from Instrumentation Pipe in JMTR was established and organized by specialists from inside and outside JAERI on December 16 and its meeting was held in public 3 times by 6th January, 2003. They found out the cause and countermeasures of cracks, and also investigated enhancement of safety management. As the result, it was considered that the leakage started around the 6th of December 2002 and the cause of the cracks was due to fatigue by vibration of the charging pump during operation. The committee discovered following incorrect actions in the safety management. First, operation of JMTR was continued without keeping careful watch in spite of occurrence of leakage detector alarm. Second, every time when the alarm range for the reasons other than the leakage, appropriate investigation and countermeasure were not taken. Third, the manager in charge didn't have a fair understanding of the situation and didn't give an appropriate direction. This is the report on the cause and countermeasures of cracks and enhancement of safety management. (author)

  20. Transanal stent in anterior resection does not prevent anastomotic leakage

    DEFF Research Database (Denmark)

    Bülow, Steffen; Bulut, O; Christensen, Ib Jarle

    2006-01-01

    OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS AND METH....... On this basis it was decided to discontinue the study prematurely for ethical reasons. CONCLUSION: Decompression of the anastomosis with a transanal stent does not reduce the risk of anastomotic leakage after anterior resection.......OBJECTIVE: A defunctioning transanal stent may theoretically reduce the leakage rate after anterior rectal resection. We present a randomized open study with the aim of comparing the leakage rate after anterior resection with a loop ileostomy, a transanal stent, both or neither. PATIENTS...... AND METHODS: Randomized open trial of 194 patients operated in 11 hospitals during September 2000 to September 2003 with anterior resection for a mobile rectal tumour, 115 men and 79 women, median age 68 years (range 37-90 years). The surgeon decided upon the use of a protective ileostomy, and after...

  1. New Method for Leakage Detection by Using Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Mohammad Attari

    2018-03-01

    Full Text Available Nowadays water loss has been turned into a global concern and on the other hand the demand for water is increasing. This problem has made the demand management and consumption pattern reform necessary. One of the most important methods for managing water consumption is to decrease the water loss. In this study by using neural networks, a new method is presented to specify the location and quantity of leakages in water distribution networks.  In this method, by producing the training data and applying it to neural network, the network is able to determine approximate location and quantity of nodal leakage with receiving the nodal pressure. Production of training data is carried out by applying assumed leakage to specific nodes in the network and calculating the new nodal pressures. The results show that by minimum use of hydraulic data taken from pressures, not only this method can determine the location of nodal leakages, but also it can specify the amount of leakage on each node with reasonable accuracy.

  2. Gas-path leakage seal for a gas turbine

    Science.gov (United States)

    Wolfe, C.E.; Dinc, O.S.; Bagepalli, B.S.; Correia, V.H.; Aksit, M.F.

    1996-04-23

    A gas-path leakage seal is described for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a gas turbine (such as combustor casing segments). The seal includes a generally imperforate foil-layer assemblage which is generally impervious to gas and is located in the leakage-gap. The seal also includes a cloth-layer assemblage generally enclosingly contacting the foil-layer assemblage. In one seal, the first edge of the foil-layer assemblage is left exposed, and the foil-layer assemblage resiliently contacts the first member near the first edge to reduce leakage in the ``plane`` of the cloth-layer assemblage under conditions which include differential thermal growth of the two members. In another seal, such leakage is reduced by having a first weld-bead which permeates the cloth-layer assemblage, is attached to the metal-foil-layer assemblage near the first edge, and unattachedly contacts the first member. 4 figs.

  3. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  4. Risk factors, treatment and impact on outcomes of bile leakage after hemihepatectomy.

    Science.gov (United States)

    Zheng, Si-Ming; Li, Hong; Li, Gen-Cong; Yu, Dan-Song; Ying, Dong-Jian; Zhang, Bin; Lu, Cai-De; Zhou, Xin-Hua

    2017-07-01

    Risk factors for bile leakage after hemihepatectomy are unknown. A prospectively maintained database review identified patients undergoing hemihepatectomy between 1 January 2009 and 30 September 2014. Patients were divided into B/C and non-B/C bile leakage groups. Risk factors for bile leakage were predicted and assessments of their impact on patients were made. Bile leakage occurred in 91 of the 297 patients (30.6%); 64 cases were classified as grade B bile leakage (21.5%) and three cases as grade C bile leakage (1.0%). Multivariate analysis confirmed that elevated preoperative alanine transaminase (ALT), positive bile culture during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery were risk factors for B/C grade bile leakage (P bile leakage (P bile leakage (P bile leakage group were higher than those in the non-B/C bile leakage group (P bile leakage group also required prolonged hospitalization (P 0.05). Patient with elevated preoperative ALT, positive bile cultures during surgery, hilar bile duct plasty, bilioenteric anastomosis and laparoscopic surgery are more likely to complicate bile leakage. We should use biliary drainage such as preoperative PTBD, ENBD or intraoperative Kehr's T-tube drainage to reduce and treat bile leakage in patients with high risk of bile leakage. © 2015 Royal Australasian College of Surgeons.

  5. Air Leakage Rates in Typical Air Barrier Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Hun, Diana E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Atchley, Jerald Allen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Childs, Phillip W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    Estimates for 2010 indicate that infiltration in residential buildings was responsible for 2.85 quads of energy (DOE 2014), which is about 3% of the total energy consumed in the US. One of the mechanisms being implemented to reduce this energy penalty is the use of air barriers as part of the building envelope. These technologies decrease airflow through major leakage sites such as oriented strand board (OSB) joints, and gaps around penetrations (e.g., windows, doors, pipes, electrical outlets) as indicated by Hun et al. (2014). However, most air barrier materials do not properly address leakage spots such as wall-to-roof joints and wall-to-foundation joints because these are difficult to seal, and because air barrier manufacturers usually do not provide adequate instructions for these locations. The present study focuses on characterizing typical air leakage sites in wall assemblies with air barrier materials.

  6. Evaluation of isolation valve leakage in alternate charging piping

    International Nuclear Information System (INIS)

    Strauch, P.L.; Roarty, D.H.; Brice-Nash, R.L.

    1995-01-01

    The chemical and volume control system (CVCS) alternate charging flow path at an operating pressurized water reactor (PWR) plant was determined to be susceptible to adverse stresses from isolation valve leakage. Isolation valve leakage had resulted in pipe cracks at several nuclear units worldwide, as described in United States Nuclear Regulatory Commission Bulletin 88-08 and its supplements. To provide for continuing assurance that cracks would not initiate over the plant life, the operators considered performing fatigue evaluation to demonstrate structural integrity of the system. This evaluation included heat transfer, stress and fatigue analysis, using methods described in Electric Power Research Institute Report ''Thermal Stratification, Cycling, and Striping (TASCS),'' March 1994. The evaluation concluded that the fatigue usage would be less than 1.0 under worst case isolation valve leakage conditions, and therefore a significant investment in permanent temperature monitoring was avoided

  7. Functions and requirements for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides the initial functions and requirements for the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. A Mission Analysis has been completed, this document reflects the next step in the systems engineering approach to decompose the mission into primary functions and requirements. The functions and requirements in this document apply to mitigative actions to be taken regarding below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage mitigation is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities

  8. Research on leakage detection of nuclear power station primary loop

    International Nuclear Information System (INIS)

    Cao Shengquan; Yang Jicai; Li Jianjun; Dong Zhijuan; Ren Juyan; Zhang Pinyuan

    1993-01-01

    The sensor of leak-detection system is a special humidity-sensitive element. In this system, the collection and treatment of detected data, and the leakage alarm are controlled by a simple board computer. The three parameters A, B and C are set up in this system, and the alarm will give out when signal surpasses values of B and C at the same time. The effects of environment humidity and temperature on collection of detected data are considered, and the leakage alarm is reliable. When the leakage rate of water at 320 degree C and 12.2 MPa is 0.3 g/min, the alarm signal will sent out within 5 s

  9. Leakage of pressurized gases through unlined concrete containment structures

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.

    1983-01-01

    Eight reinforced concrete specimens were fabricated and subjected to tensile membrane forces and air pressure to study the air leakage characteristics in cracked reinforced concrete members. A mathematical expression for the rate of pressurized air flowing through an idealized crack is presented. The mathematical expression is refined by using the experimental data to describe the air flow rate through any given crack pattern. Graphical charts are also presented for the calculation of the air leakage rate through concrete cracks. The concept of equivalent crack width for a given crack pattern is introduced. The mathematical expression and graphical charts are modified to include this equivalent crack width concept. The proposed technique is applicable for the prediction of the leakage from concrete containment structures or any similar structures due to high internal pressure sufficient to initiate cracking. (orig.)

  10. Suppression of tunneling leakage current in junctionless nanowire transistors

    International Nuclear Information System (INIS)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-01-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out. (paper)

  11. Suppression of tunneling leakage current in junctionless nanowire transistors

    Science.gov (United States)

    Lou, Haijun; Li, Dan; Dong, Yan; Lin, Xinnan; He, Jin; Yang, Shengqi; Chan, Mansun

    2013-12-01

    In this paper, the characteristics of tunneling leakage current for the dual-material gate junctionless nanowire transistor (DMG-JNT) are investigated by three-dimensional numerical simulations and compared with conventional junctionless nanowire transistor (JNT). The suppression of the tunneling leakage current on the JNT by introducing an energy band step with the DMG structure is verified and presented for the first time. The effects of channel length on the DMG-JNT and the JNT are also studied. Results showed that the tunneling leakage current of the DMG-JNT is two orders smaller than that of the JNT, and further, the DMG-JNT exhibits superior scaling capability. Two key design parameters of the DMG-JNT, control gate ratio (Ra) and work function difference (δW), have been optimized and the optimal ranges of Ra and δW are pointed out.

  12. On the Connection between Leakage Tolerance and Adaptive Security

    DEFF Research Database (Denmark)

    Nielsen, Jesper Buus; Venturi, Daniele; Zottarel, Angela

    2013-01-01

    We revisit the context of leakage-tolerant interactive protocols as defined by Bitanski, Canetti and Halevi (TCC 2012). Our contributions can be summarized as follows: For the purpose of secure message transmission, any encryption protocol with message space M and secret key space SK tolerating...... at the end of the protocol execution, if and only if the protocol has passive adaptive security against an adaptive corruption of one party at the end of the protocol execution. This shows that as soon as a little leakage is tolerated, one needs full adaptive security. In case more than one party can...... be corrupted, we get that leakage tolerance is equivalent to a weaker form of adaptivity, which we call semi-adaptivity. Roughly, a protocol has semi-adaptive security if there exist a simulator which can simulate the internal state of corrupted parties, however, such a state is not required...

  13. On camera-based smoke and gas leakage detection

    Energy Technology Data Exchange (ETDEWEB)

    Nyboe, Hans Olav

    1999-07-01

    Gas detectors are found in almost every part of industry and in many homes as well. An offshore oil or gas platform may host several hundred gas detectors. The ability of the common point and open path gas detectors to detect leakages depends on their location relative to the location of a gas cloud. This thesis describes the development of a passive volume gas detector, that is, one than will detect a leakage anywhere in the area monitored. After the consideration of several detection techniques it was decided to use an ordinary monochrome camera as sensor. Because a gas leakage may perturb the index of refraction, parts of the background appear to be displaced from their true positions, and it is necessary to develop algorithms that can deal with small differences between images. The thesis develops two such algorithms. Many image regions can be defined and several feature values can be computed for each region. The value of the features depends on the pattern in the image regions. The classes studied in this work are: reference, gas, smoke and human activity. Test show that observation belonging to these classes can be classified fairly high accuracy. The features in the feature set were chosen and developed for this particular application. Basically, the features measure the magnitude of pixel differences, size of detected phenomena and image distortion. Interesting results from many experiments are presented. Most important, the experiments show that apparent motion caused by a gas leakage or heat convection can be detected by means of a monochrome camera. Small leakages of methane can be detected at a range of about four metres. Other gases, such as butane, where the densities differ more from the density of air than the density of methane does, can be detected further from the camera. Gas leakages large enough to cause condensation have been detected at a camera distance of 20 metres. 59 refs., 42 figs., 13 tabs.

  14. The Effect of Internal Leakages on Thermal Performance in NPPs

    International Nuclear Information System (INIS)

    Heo, Gyun Young; Kim, Doo Won; Jang, Seok Bo

    2007-01-01

    Since the Balance Of Plant (BOP, limited to a turbine cycle in this study) does not contain radioactive material, regulatory authorities did not need to have concerns on it. As the interests on safety and performance is getting more serious and extensive, controlling the level of safety and performance of a BOP have just begun or is about to begin. The performance standards or ageing management programs of the major equipment in a BOP is being developed. The regulatory requirements for tests and/or maintenance are being actively built up. There is also a probabilistic approach quantifying performance of a BOP. The study on quantifying the rate of unanticipated shutdowns caused by careless maintenance and/or tests conducted in a BOP is going on. In this study, the modeling of the entire BOP and the methodologies of thermal performance analysis should be one of the must-have items as well. This study was achieved to ensure fundamental skills related to 1) the detailed steady-state modeling of a BOP and 2) thermal performance analysis under various conditions. Particularly, the paper will focus on the effect of internal leakages inside the valves and FeedWater Heaters (FWHs). The internal leakage is regarded as the flow movement through the isolated path but remaining inside the system boundary of a BOP. For instance, the leakage from one side of a valve seat to the other side, or the leakage through the cracked tubes or tube-sheets in a heat exchanger correspond to internal leakages. We made a BOP model of OPR1000 and investigated thermal performance under the internal leakage in Turbine Bypass Condenser Dump Valves (TBCDV) and FWHs

  15. Marginal Leakage of Class V Composite Resin Restorations

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2018-01-01

    Full Text Available >Introduction: Marginal leakage is one of the significant causes of restoration failure. This in-vitro study was conducted to compare cone beam computed tomography (CBCT and dye-penetration methods for determining marginal leakage at gingival surface of class V resin composite restorations.Materials and Methods: Class V cavities were prepared on the buccal surfaces of nineteen caries-free extracted human molar teeth. Cavities were conditioned and filled. The teeth were immersed in a 50% w/w aqueous silver nitrate solution for 24 h and were taken out and rinsed with distilled water. Then, they were put into a developing solution. Whole specimens were first viewed with CBCT and were then sectioned and evaluated by stereomicroscope.Results: Measurement of agreement between CBCT and stereomicroscope revealed that 15 (78.9% teeth had score 0, 1 (5.3% tooth had score 1, and 1 (5.3% tooth had score 2 in both techniques. Measurement of agreement between CBCT and stereomicroscope techniques, in the detection of marginal leakage, was 89.5% (Kappa coefficient = 0.627, P = 0.00. The Wilcoxon paired rank test revealed no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin (P = 0.157.Conclusion: Considering the limitations of the study, there was no significant difference between the results of CBCT and stereomicroscope in measuring the leakage at gingival margin of class V composite restorations. CBCT can be used noninvasively to detect the marginal leakage of gingival wall of class V composite restorations using aqueous silver nitrate solution as a tracer.

  16. Root cause evaluation of pressurizer relief valve leakage

    International Nuclear Information System (INIS)

    Olson, D.E.; Voll, B.J.

    1996-01-01

    Pressurizer relief valves at two pressurized water reactor units experienced unacceptable leakage during plant heatup. The leakage was suspected to be caused by excessive pipe loads on the valves. This paper describes how monitoring via hard-wired transducers and a digital data acquisition system was used to quantify the pipe loads on the valves, and assist in determining the root cause of the pipe loads and appropriate corrective actions. The selection of the parameters monitored, how the monitoring was accomplished and interpretation of the results is discussed. The corrective actions implemented based on the monitoring results are also discussed

  17. Leakage radiation spectroscopy of organic/dielectric/metal systems

    DEFF Research Database (Denmark)

    Fiutowski, Jacek; Kawalec, Tomasz; Kostiučenko, Oksana

    2014-01-01

    side of a hemisphere fused silica prism with an index matching liquid was illuminated under normal incidence by a He-Cd 325 nm laser. Two orthogonal linear polarizations were used both parallel and perpendicular to the detection plane. Spectrally resolved leakage radiation was observed on the opposite......Leakage radiation spectroscopy of organic para-Hexaphenylene (p-6P) molecules has been performed in the spectral range 420-675 nm which overlaps with the p-6P photoluminescence band. The p-6P was deposited on 40 nm silver (Ag) films on BK7 glass, covered with SiO2 layers. The SiO2 layer thickness...

  18. Method for detecting resin leakage in LWR coolant

    International Nuclear Information System (INIS)

    Girard, J.E.

    1988-05-01

    Resin leakage from condensate polishing units can result in steam generator corrosion. This report describes the development of a resin leakage detection method based in analyzing the organic breakdown products released from resin on heating. The breakdown products are analyzed using high performance liquid chromatography (HPLC) with fluorescence detection. Some of the organic products formed have been identified. A design for a resin monitoring unit, suitable for incorporation into the IONTRAC system, is presented. Theoretically, detection of ppB levels of resin by processing about one liter of water, is possible

  19. Carbon leakage revisited. Unilateral climate policy under directed technical change

    International Nuclear Information System (INIS)

    Maria, Corrado Di; Van derWerf, E.

    2005-01-01

    This paper analyzes the consequences of unilateral climate policy in the presence of directed technical change. We develop a dynamic two-country model in which two otherwise identical countries differ in their environmental policy: one of the countries enforces a (binding) cap on emissions while the other does not. Focusing on carbon leakage, we show how, compared with a 'traditional' endogenous growth model, directed technical change will always lead to lower emissions in the unconstrained country. When clean and dirty goods are good substitutes, it may even be induced to reduce its emissions below the optimum level when both countries are unconstrained, so leakage is negative

  20. Leakage tests of wall segments of reactor containments

    International Nuclear Information System (INIS)

    Rizkalla, S.H.; Simmonds, S.H.; MacGregor, J.G.

    1979-10-01

    Two prestressed concrete wall segments simulating portions of containment walls were loaded by axial tensile forces to cause cracking of the concrete. At each load increment air pressure was applied in steps up to 21 psi to one side of the segment and the rate of leakage of air through the cracked concrete section was measured. A theoretical equation for the flow of air through concrete cracks is developed and the results from one leakage test are used to determine the dimensionless constant required for this equation. (author)

  1. ELECTROPHYSIOLOGICAL EVALUATION OF THE TRANSITORY DYSFUNCTION OF THE NERVUS TRIGEMINUS AND THE NERVUS FACIALIS IN THE PATIENTS SUFFERING FROM THE DIABETES NEUROPATHY BY EXAMINING THE BLINK REFLEX

    Directory of Open Access Journals (Sweden)

    Milica Lazovic

    2000-11-01

    Full Text Available In 90 patients with clinically mild diabetes neuropathy (DN with no clinic signs of any affection of the nervus trigeminus (NTR and of the nervus facialis (NF including 50 with the insulin-independent diabetes (IND and 40 with the insulin-dependent diabetes (IZD of average age between 44,23+12,56 years of average diabetes duration of 9,42±7,85 years, the latencies (in ms Rl, R2 and R2' of the blink reflex response (BR after the nervus supraorbital is electric stimulation are determined. Besides, in the given patients the values (in m/s of the motor (MBP and of the sensitive transmission rate (SBP of the impulse along the nervus peroneus (NP and the nervus tibialis (NT are also determined. The control group consisted of 50 healthy persons of respective age.On the same day when the electrophysiological examination was done, the following biochemic parameters were determined in the patients' serum, namely, the glycemia profile with calculation of the glycemia average value (MBG as well as the values of the glycolized chemoglobine (HgAl, of the basal insulin level and of sodium (Na and potassium (K. After that, the correlation between the given electrophysiological and the biochemic parameters was examined as well as that between the given parameters and the age of the examined and the diabetes duration.A statistically significant correlation (p(,(5 between the values of the other examined parameters registered.The obtained results show that hyperglycemia causes the emergence of the transitory dysfunction of the NTR and/or the NF in the patients with the IND and the clinically mild DN. The dysfunction of the NTR and/or the NF is approximately symmetrically present on the left and the right side in the patients with the IND and the clinically mild DN while in the persons with the IZD and the clinically mild DN there is asymmetry of the functional disturbance in the system of the NT-NF complex which is probably related to different effects of the

  2. 75 FR 29699 - Total Inward Leakage Requirements for Respirators

    Science.gov (United States)

    2010-05-27

    ... or other half-mask respirator inward leakage measurement, and offer any additional comments on the..., facsimile (412) 386-4089, e-mail [email protected] . SUPPLEMENTARY INFORMATION: I. Background The Department of... order to conduct tests and prepare responses. On April 20, 2010, NIOSH responded by reopening the docket...

  3. University student's education after Fukushima nuclear leakage crisis

    International Nuclear Information System (INIS)

    Dou Daying; Gu Jianzhong; Zheng Jianying

    2012-01-01

    Fukushima nuclear leakage crisis after 3.11 earthquake and tsunami, the horrible INES-7 accident warns the colleagues all over the world. Own much to the experts' reports on public media, INES classification, basic knowledge of nuclear reactor, nuclear safety and protection had been discussed and brain-stormed in detail. (authors)

  4. Leakage monitoring equipment of fuel element by delayed neutron method

    International Nuclear Information System (INIS)

    Ji Changsong; Zhang Shulan; Zhang Shuheng

    1999-01-01

    Based on monitoring results of delayed neutrons from reactor first circle water, the leakage of reactor fuel elements is monitored. A monitoring equipment consisted of an array of 3 He proportional counter tubes with 75 s delay has been developed. The neutron detection efficiency of 6.1% is obtained

  5. Benchmarking leakage from water reticulation systems in South Africa

    African Journals Online (AJOL)

    driniev

    Abstract. A project to assess the levels of leakage in 30 water utilities throughout South Africa was initiated by the Water ... average operating pressure, systems input volume and the compo- ... simple, user-friendly model that is based on an excel spreadsheet ..... One can see from the four graphs presented here that various.

  6. Development of Wireless System for Containment Integrated Leakage Rate Test

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Oh, Eung-Se; Yang, Seung-Ok

    2006-01-01

    The containment system leakage rate should be estimated periodically with reliable test equipment. In light-water reactor nuclear power plants, ANSI/ANS- 56.8 is a basis for determining leakage rates. Two types of data acquisition system, centralized type and networked type, has been used. In centralized type, all sensors are connected directly from sensors in the containment to the measuring equipment outside the building. The other hand, the networked type has several branch chains which connect one group of the network-sensors together. To test leakage rate, more than 20 temperature sensors and 6 humidity sensors, which are different for each plant, should be installed on a specific level in the containment. A wireless technology gives the benefits such as reducing installation efforts, making pretest easy, so it is widely used more and more in the plant monitoring. As the containment system has many kinds of complex barriers to the radio frequency, the radio power and frequency band for better transmission rate as well as the interference by the radio frequency should be considered. The overview of the wireless sensor system for the containment leakage rate test is described here and the test results on Yonggwang unit 4 PWR plant is presented

  7. Reaction-driven casing expansion : potential for wellbore leakage mitigation

    NARCIS (Netherlands)

    Wolterbeek, Timotheus K. T.; van Noort, Reinier; Spiers, Christopher J.

    It is generally challenging to predict the post-abandonment behaviour and integrity of wellbores. Leakage is, moreover, difficult to mitigate, particularly between the steel casing and outer cement sheath. Radially expanding the casing with some form of internal plug, thereby closing annular voids

  8. Carbon Leakage Revisited : Unilateral Climate Policy with Directed Technical Change

    NARCIS (Netherlands)

    Di Maria, C.; van der Werf, E.H.

    2005-01-01

    The increase in carbondioxide emissions by some countries in reaction to an emission reduction by countries with climate policy (carbon leakage) is seen as a serious threat to unilateral climate policy.Using a two-country model where only one of the countries enforces an exogenous cap on emissions,

  9. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Science.gov (United States)

    2010-10-01

    ... following minimum requirements: (1) A leakage survey with leak detector equipment must be conducted in business districts, including tests of the atmosphere in gas, electric, telephone, sewer, and water system... survey with leak detector equipment must be conducted outside business districts as frequently as...

  10. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  11. Superconducting coil configurations, with low flux leakage, for energy storage

    International Nuclear Information System (INIS)

    Vincent-Viry, O.; Mailfert, A.; Trassart, D.

    2001-01-01

    This paper presents two original types of SMES structures for energy storage. These two groups of SMES structures proceeded from an ideal structure: the full toroid, are modeled by the use of purely surface current densities. Their main advantage is to present no flux leakage, they give then satisfactory solution to the problem of energy storage. (orig.)

  12. Optimized quantization in Zero Leakage Helper data systems

    NARCIS (Netherlands)

    Stanko, T.; Andini, F.N.; Skoric, B.

    2017-01-01

    Helper data systems are a cryptographic primitive that allows for the reproducible extraction of secrets from noisy measurements. Redundancy data called helper data makes it possible to do error correction while leaking little or nothing (Zero Leakage) about the extracted secret string. We study the

  13. Modelling of heterogenous neutron leakages in a nuclear reactor

    International Nuclear Information System (INIS)

    Wohleber, X.

    1997-01-01

    The TIBERE Model is a neutron leakage method based on B 1 heterogeneous transport equation resolution. In this work, we have studied the influence of the reflection mode at the boundary of the assembly. In particular the White boundary condition has been implemented in the APOLLO2 neutron transport code. We have compared the two TIBERE kinds of boundary conditions (specular and white) with the classical B 1 homogeneous leakage method in the modelling of some reactors. We have remarked the better capability of the TIBERE Model to compute voided assemblies. The white boundary condition is also able to compute a completely voided assembly and, besides, wins a factor 10 in CPU time in comparison with the specular boundary condition. These two heterogenous leakage formalisms have been tested on a partially voided experiment and have shown that the TIBERE Model can compute this kind of situation with a greater precision than the classical B 1 homogeneous leakage method, and with a shorter computational time. (author)

  14. Exploitation of Unintentional Information Leakage from Integrated Circuits

    Science.gov (United States)

    Cobb, William E.

    2011-01-01

    The information leakage of electronic devices, especially those used in cryptographic or other vital applications, represents a serious practical threat to secure systems. While physical implementation attacks have evolved rapidly over the last decade, relatively little work has been done to allow system designers to effectively counter the…

  15. Visual Inspection of Water Leakage from Ground Penetrating Radar Radargram

    Science.gov (United States)

    Halimshah, N. N.; Yusup, A.; Mat Amin, Z.; Ghazalli, M. D.

    2015-10-01

    Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR) as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD) of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  16. Leakage detection in underground gas mains with radioaktive argon

    International Nuclear Information System (INIS)

    Schmitz, J.

    1975-01-01

    In the field of gas supply, radionuclide techniques are suitable for the routine monitoring of transport mains by means of highly active tracer clouds and a measuring scraper as well as for exact leakage detection in local gas distribution systems. Very good results are obtained in the case of mains lying lower than 1.5 m if the length and alignment of the pipe section allow a towing probe to be pulled through. This was investigated systematically on a model stretch under practical conditions. The attempts to detect leakages were made with the aid of the radioactive isotope 41 Ar. Under conditions close to practice concerning pipe bedding, branching, pre-pressure, and leakage diameter, a leak with leakage rates as small as approx. 1 l/min could be measured with the aid of a towing probe with a precision of +-0.5 m. This accuracy is another advantage of this method. Branching and fittings with a big dead volume do not interfere with the evaluation. The investment for this method can be compared to other physical/technical investigations on mains, e.g. weld seam tests. (orig./LN) [de

  17. VISUAL INSPECTION OF WATER LEAKAGE FROM GROUND PENETRATING RADAR RADARGRAM

    Directory of Open Access Journals (Sweden)

    N. N. Halimshah

    2015-10-01

    Full Text Available Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  18. Colorectal anastomotic leakage: Aspects of prevention, detection and treatment

    NARCIS (Netherlands)

    F. Daams (Freek); M. Luyer (Misha); J.F. Lange (Johan)

    2013-01-01

    textabstractAll colorectal surgeons are faced from time to time with anastomotic leakage after colorectal surgery. This complication has been studied extensively without a significant reduction of incidence over the last 30 years. New techniques of prevention, by innovative anastomotic techniques

  19. First principle leakage current reduction technique for CMOS devices

    CSIR Research Space (South Africa)

    Tsague, HD

    2015-12-01

    Full Text Available This paper presents a comprehensive study of leakage reduction techniques applicable to CMOS based devices. In the process, mathematical equations that model the power-performance trade-offs in CMOS logic circuits are presented. From those equations...

  20. Incidence and management of chyle leakage after esophagectomy

    NARCIS (Netherlands)

    Lagarde, Sjoerd M.; Omloo, Jikke M. T.; de Jong, Koen; Busch, Olivier R. C.; Obertop, Hugo; van Lanschot, J. Jan B.

    2005-01-01

    BACKGROUND: Postoperative chyle leakage is a rare but well-recognized complication after esophageal surgery. The aim of this study was to identify its incidence and potentially predisposing factors and to assess the consequences and management. METHODS: A consecutive series of 536 patients who

  1. Characterization of CO2 leakage into the freshwater body

    DEFF Research Database (Denmark)

    Singh, Ashok; Delfs, Jens Olaf; Shao, H.

    2013-01-01

    urrent research into CO2 capture and storage is dominated by improving the CO2 storage capacity. In this context, risk related to CO2 leakage is an important issue which may cause environmental problems, particularly when freshwater resources nearby are intruded by the CO2 plume. In this work...

  2. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  3. Effects of Aspergillus niger inoculum concentration upon the kinetics of starchy wastewater pretreatment in a tanks-in-series bioreactor under transitory conditions

    Directory of Open Access Journals (Sweden)

    L. Coulibaly

    2007-12-01

    Full Text Available This paper discusses the effects of three Aspergillus niger inoculum concentrations (0.12, 2.3 and 3.6 g/l upon the kinetics of starch pretreatment under aerobic and transitory conditions using a tanks-in-series reactor. A synthetic wastewater containing starch as model polysaccharide was fed into the reactor system to study this polymer transformation by Aspergillus niger. Starch and metabolites (oligosaccharides with a molecular weight lower than 1 kDa in the individual reactors were quantified respectively by the starch iodine complex (SIC and anthrone methods. Enzyme activities were characterised with API ZYM kits. Starch degradation and metabolite accumulation were both influenced by both fungal inoculum and reactor HRT. Starch degradation improved from 34 to 99% with a parallel in increase inoculum concentration from 0.12 to 3.6 g/l. An overall of 400 mg/l of metabolites accumulated in the reactor system. A. niger secreted both extracellular and cell-wall-bound enzymes among which amylases.

  4. Factors related to ostomy leakage in the community setting.

    Science.gov (United States)

    Ratliff, Catherine R

    2014-01-01

    The purpose of this study was to describe demographic and clinical variables related to ostomy pouch leakage from those discharged from a major medical center during a 2-year period. A convenience sample of 198 persons with an ostomy was obtained using the ICD-9 (International Classification of Diseases, Ninth Revision) codes for colostomy, ileostomy, and ileal conduit for patients who were discharged from the medical center within the time frame of July 2009 to July 2011. One hundred seven participants (55%) returned a completed survey. Respondents included 57 men (53%) and 50 women (47%). The mean age was 60 years with age range from 23 to 91 years. Fecal ostomies made up the majority of the stomas representing 71 patients (66%). A descriptive, cross-sectional research design was used to describe clinical variables related to ostomy pouch leakage for those discharged from a major academic medical center over a 2-year period of time. Participants were mailed an introductory letter from the principal investigator, a self-administered questionnaire, and a prepaid return envelope. Ninety-three patients (87%) reported leakage; however, 48 patients (45%) stated that they did not leak often. A logistic regression was estimated to determine which variables were significant predictors of the dependent variable of leaking status (no/seldom leaking vs more frequent leaking). Two variables were individually significant predictors, sex (P = .021) and 2-piece pouch (P = .015). Women were 4 times more likely to be in the more frequent leaking group than were men. Those who were wearing 2-piece pouches were 78% less likely to be in the more frequent leaking group. Participants with ileostomies or urostomies were more likely to be in the more frequent leaking group and those with peristomal skin irritation were more likely to be in the more frequent leaking group. Findings from this study reveal that women were more likely to experience leakage than men and that wearing a 2-piece

  5. Understanding and managing leakage in forest-based greenhouse-gas-mitigation projects.

    Science.gov (United States)

    Schwarze, Reimund; Niles, John O; Olander, Jacob

    2002-08-15

    A major concern about land use, land-use change and forestry (LULUCF) projects under the Clean Development Mechanism (CDM) is the potential for leakage. Leakage refers to a net increase of greenhouse-gas emissions in an area outside the project resulting from the CDM activity. This paper provides an overview of leakage, its definitions and its causes. It describes ways that LULUCF projects may suffer from leakage and attempts to assess the magnitude of leakage risks for different LULUCF project types. It also summarizes some of the approaches, both in terms of policies and project development, to address LULUCF leakage.

  6. Early detection of anastomotic leakage after elective low anterior resection.

    Science.gov (United States)

    Fouda, Elyamani; El Nakeeb, Ayman; Magdy, Alaa; Hammad, Enas A; Othman, Gamal; Farid, Mohamed

    2011-01-01

    Colorectal anastomotic leakage is a serious complication leading to major postoperative morbidity and mortality. In the present study, we investigated the early detection of anastomotic leakage before its clinical presentation. Fifty-six patients with rectal cancer were included prospectively in this study. All patients underwent elective low anterior resection. Peritoneal samples were collected from the abdominal drains at the first, third, and fifth days postoperatively for bacteriological study (quantitative cultures for both aerobes and anaerobes) and cytokines (IL-6, IL-10, TNF) measurement. Patients were divided into two groups: those without symptomatic or clinical evidence of anastomotic leakage (AL; group 1) and those with clinical evidence of AL (group 2). Study variables included hospital stay, wound infection, operative time, blood loss, height of anastomosis, intraperitoneal cytokines, and microbiological study of peritoneal fluid. Clinically evident AL occurred in eight patients (14.3%) and diagnosed postoperatively on median day 6. Intraperitoneal bacterial colonization and cytokine levels were significantly higher in patients with clinical evidence of AL. Wound infection was significantly higher in anastomotic leakage group. The hospital stay for the patients with anastomotic leakage was significantly longer than those without AL (14 ± 1.41 vs. 5.43 ± 0.89 days). A significant difference among two groups was observed regarding operative time, blood loss, blood transfusion, and height of the anastomosis. The peritoneal cytokines levels and intraperitoneal bacterial colonization might be an additional diagnostic tool that can support the decision making of surgeons for early detection of anastomotic leak in colorectal surgery.

  7. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario.

    Science.gov (United States)

    Ma, Jing; Zhang, Wangyuan; Zhang, Shaoliang; Zhu, Qianlin; Feng, Qiyan; Chen, Fu

    2017-01-01

    The technology of carbon dioxide (CO 2 ) capture and storage (CCS) has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO 2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO 2 geological storage was designed to investigate the short-term effects of different CO 2 leakage concentration (from 400 g m -2 day -1 to 2,000 g m -2 day -1 ) on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO 2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO 2 concentrations. Increasing CO 2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 ( p soil CO 2 concentration increased. The dominant phylum in the soil samples was Proteobacteria , whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% ( p soil ecosystems.

  8. Radiation leakage dose from Elekta electron collimation system.

    Science.gov (United States)

    Pitcher, Garrett M; Hogstrom, Kenneth R; Carver, Robert L

    2016-09-08

    This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were measured and calculated for two primary purposes: 1) to evaluate and document the out-of-field leakage dose in the patient plane and 2) to validate the dose distributions calculated using a BEAMnrc Monte Carlo (MC) model for out-of-field dose profiles. Off-axis dose profiles were measured in a water phantom at 100 cm SSD for 1 and 2 cm depths along the in-plane, cross-plane, and both diagonal axes using a cylindrical ionization chamber with the 10 × 10 and 20 × 20 cm2 applicators and 7, 13, and 20 MeV beams. Dose distributions were calculated using a previously developed BEAMnrc MC model of the Elekta Infinity accelerator for the same beam energies and applicator sizes and compared with measurements. Measured results showed that the in-field beam flatness met our acceptance criteria (± 3% on major and ±4% on diagonal axes) and that out-of-field mean and maximum percent leakage doses in the patient plane met acceptance criteria as specified by the International Electrotechnical Commission (IEC). Cross-plane out-of-field dose profiles showed greater leakage dose than in-plane profiles, attributed to the curved edges of the upper X-ray jaws and multileaf collimator. Mean leakage doses increased with beam energy, being 0.93% and 0.85% of maximum central axis dose for the 10 × 10 and 20 × 20 cm2 applicators, respectively, at 20 MeV. MC calculations predicted the measured dose to within 0.1% in most profiles outside the radiation field; however, excluding model-ing of nontrimmer applicator components led to calculations exceeding measured data by as much as 0.2% for some regions

  9. Perioperative Statin Therapy Is Not Associated With Reduced Risk of Anastomotic Leakage After Colorectal Resection

    DEFF Research Database (Denmark)

    Bisgård, Anne Sofie; Noack, Morten Westergaard; Klein, Mads

    2013-01-01

    Anastomotic leakage is a serious complication of colorectal surgery. Several studies have demonstrated the beneficial pleiotropic effects of statins, and preliminary studies have suggested that perioperative statin treatment may be associated with reduced risk of anastomotic leakage....

  10. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events

    OpenAIRE

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while c...

  11. Evaluation of the White Test for the Intraoperative Detection of Bile Leakage

    OpenAIRE

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was c...

  12. Transitory increased blood pressure after upper airway surgery for snoring and sleep apnea correlates with the apnea-hypopnea respiratory disturbance index

    Directory of Open Access Journals (Sweden)

    M.T.M. Araújo

    2003-12-01

    Full Text Available A transitory increase in blood pressure (BP is observed following upper airway surgery for obstructive sleep apnea syndrome but the mechanisms implicated are not yet well understood. The objective of the present study was to evaluate changes in BP and heart rate (HR and putative factors after uvulopalatopharyngoplasty and septoplasty in normotensive snorers. Patients (N = 10 were instrumented for 24-h ambulatory BP monitoring, nocturnal respiratory monitoring and urinary catecholamine level evaluation one day before surgery and on the day of surgery. The influence of postsurgery pain was prevented by analgesic therapy as confirmed using a visual analog scale of pain. Compared with preoperative values, there was a significant (P < 0.05 increase in nighttime but not daytime systolic BP (119 ± 5 vs 107 ± 3 mmHg, diastolic BP (72 ± 4 vs 67 ± 2 mmHg, HR (67 ± 4 vs 57 ± 2 bpm, respiratory disturbance index (RDI characterized by apnea-hypopnea (30 ± 10 vs 13 ± 4 events/h of sleep and norepinephrine levels (22.0 ± 4.7 vs 11.0 ± 1.3 µg l-1 12 h-1 after surgery. A positive correlation was found between individual variations of BP and individual variations of RDI (r = 0.81, P < 0.01 but not between BP or RDI and catecholamines. The visual analog scale of pain showed similar stress levels on the day before and after surgery (6.0 ± 0.8 vs 5.0 ± 0.9 cm, respectively. These data strongly suggest that the cardiovascular changes observed in patients who underwent uvulopalatopharyngoplasty and septoplasty were due to the increased postoperative RDI.

  13. In regard to Levi-Strauss’s "motive of oblivion". Structure of disturbed communication and styles of thoughts in transitory Serbia

    Directory of Open Access Journals (Sweden)

    Dragana Antonijević

    2016-02-01

    Full Text Available This paper starts with Levi-Strauss’s semantic concept that consists of oblivion, misunderstanding, indiscretion and nostalgia. Through his analysis of North American and Greek myths, Levi-Strauss concluded that "semantic filed of oblivion" has an important meaning especially in the construction of particular rules and rituals; or, in other words, it has an important part in the introduction of culture to the nature of cognitive and social processes. After the introduction of concept Structure of disturbed communication and some corrections to the Levi-Strauss’s concept, I start with the proposition that the period of transition represents unstable and ‘slippery’ time in which society negotiates different meanings. That is the time when different styles of thoughts, represented by different and powerful groups that have an impact on current social, political and ideological processes, compete with each other fighting for supremacy. Their field of communication can be seen as a field of "disturbed communication", which in the final instance has a normative function: to reinforce and regulate certain attitudes, ideas and knowledge. This is achieved through the narratives which symbolise a community of newly established order in the moment of its supposed sociohistorical stabilisation. Finally, combining two different theoretical models – Levi-Strauss’s one described above with Greimas’s ideas about structures of modes of veridiction, this paper predicts chances of particular paradigmatic forms of thought in transitory Serbia to became dominant modes of thought, despite of their current low visibility in the public sphere. In mythical terms, it seems though that their domineering efforts are predetermined to success or fail, since they position themselves according to the laws immanent to these structures themselves, which on their part a priori position these structures as powerful orpowerless, influential or non

  14. Allocation of emission permits with leakage through capital markets

    International Nuclear Information System (INIS)

    Maestad, Ottar

    2007-01-01

    This paper analyses how tradable emission permits should be allocated to firms when capital is internationally mobile. When international environmental problems are attempted solved through uncoordinated policies between countries, it might be desirable for the home country to issue free emission permits in proportion to the use of capital in order to prevent leakage through international capital movements. The desirability of free emission permits will however be reduced if capital also can be employed in a domestic non-polluting sector. In this case, it may even be optimal to tax the use of capital in the polluting sector. It is also shown that it is always optimal to subsidise the use of capital in the polluting sector if the use of labour is taxed at an optimal rate. Finally, leakage does not affect the optimal domestic emission limit as long as appropriate capital subsidies and labour taxes are implementeed. (author)

  15. Impact of the Indonesian Throughflow on Agulhas leakage

    Directory of Open Access Journals (Sweden)

    D. Le Bars

    2013-09-01

    Full Text Available Using ocean models of different complexity we show that opening the Indonesian Passage between the Pacific and the Indian oceans increases the input of Indian Ocean water into the South Atlantic via the Agulhas leakage. In a strongly eddying global ocean model this response results from an increased Agulhas Current transport and a constant proportion of Agulhas retroflection south of Africa. The leakage increases through an increased frequency of ring shedding events. In an idealized two-layer and flat-bottom eddy resolving model, the proportion of the Agulhas Current transport that retroflects is (for a wide range of wind stress forcing not affected by an opening of the Indonesian Passage. Using a comparison with a linear model and previous work on the retroflection problem, the result is explained as a balance between two mechanisms: decrease retroflection due to large-scale momentum balance and increase due to local barotropic/baroclinic instabilities.

  16. Combined approach to reduced duration integrated leakage rate testing

    International Nuclear Information System (INIS)

    Galanti, P.J.

    1987-01-01

    Even though primary reactor containment allowable leakage rates are expressed in weight percent per day of contained air, engineers have been attempting to define acceptable methods to test in < 24 h as long as these tests have been performed. The reasons to reduce testing duration are obvious, because time not generating electricity is time not generating revenue for the utilities. The latest proposed revision to 10CFR50 Appendix J, concerning integrated leakage rate testing (ILRTs), was supplemented with a draft regulatory guide proposing yet another method. This paper proposes a method that includes elements of currently accepted concepts for short duration testing with a standard statistical check for criteria acceptance. Following presentation of the method, several cases are presented showing the results of these combined criteria

  17. Correlation among ESDD, NSDD and leakage current in distribution insulators

    International Nuclear Information System (INIS)

    Montoya, G.; Ramirez, I.; Montoya, J.I.

    2004-01-01

    The maintenance of distribution networks is more effective if the insulation contamination levels are known. The selection of measuring methods of pollution levels is then crucial. The relationship between several evaluation methods of pollution levels and the operating behaviour of several insulator profiles in a polluted zone is described. Laboratory tests were carried out to reproduce pollution levels found in the field. The quantity of non-soluble materials deposited over the insulators' surface affect the magnitude of the leakage current generated over a contaminated insulator. The relationship that defines leakage current with respect to the equivalent salt deposit density (ESDD) level for a specific non-soluble material level is almost linear, from which it is possible to develop a relationship between them for each insulator. (author)

  18. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P.; Vranka, L. [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1997-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  19. Low-leakage, high-current power crowbar transformer

    International Nuclear Information System (INIS)

    Buck, R.T.; Galbraith, J.D.; Nunnally, W.C.

    1979-01-01

    The design, fabrication, and testing of two sizes of power crowbar transformers for the ZT-40 Toroidal Z-Pinch experiment at the Los Alamos Scientific Laboratory are described. Low-leakage transformers in series with the poloidal and the toroidal field coils are used to sustain magnetic field currents initially produced by 50-kV capacitor banks. The transformer primaries are driven by cost-effective, ignitron-switched, 10-kV high-density capacitor banks. The transformer secondaries, in series with the field coils, provide from 1,000 to 1,500 V to cancel the resistive voltage drop in the coil circuits. Prototype transformers, with a total leakage inductance measured in the secondary of 5 nH, have been tested with peak secondary currents in excess of 600 kA resulting from a 10-kV primary charge voltage. The test procedures and results and the mechanical construction details are presented

  20. The Impact of Statistical Leakage Models on Design Yield Estimation

    Directory of Open Access Journals (Sweden)

    Rouwaida Kanj

    2011-01-01

    Full Text Available Device mismatch and process variation models play a key role in determining the functionality and yield of sub-100 nm design. Average characteristics are often of interest, such as the average leakage current or the average read delay. However, detecting rare functional fails is critical for memory design and designers often seek techniques that enable accurately modeling such events. Extremely leaky devices can inflict functionality fails. The plurality of leaky devices on a bitline increase the dimensionality of the yield estimation problem. Simplified models are possible by adopting approximations to the underlying sum of lognormals. The implications of such approximations on tail probabilities may in turn bias the yield estimate. We review different closed form approximations and compare against the CDF matching method, which is shown to be most effective method for accurate statistical leakage modeling.

  1. Modelling of Consequences of Biogas Leakage from Gasholder

    Directory of Open Access Journals (Sweden)

    Petr Trávníček

    2017-03-01

    Full Text Available This paper describes modelling of consequences of biogas leakage from a gasholder on agricultural biogas station. Four scenarios were selected for the purpose of this work. A rupture of gasholders membrane and instantaneous explosion of gas cloud, blast of gas with delay, emptying of whole volume of gas (without initiation and initiation of gas with Jet-Fire. Leakage of gas is modelled by special software and consequences are determined on the basis of results. The first scenario was modelled with help of equations because used software does not include an appropriate model. A farm with high building density was chosen as a model case. Biogas is replaced by methane because used software does not support modelling of dispersion of mixtures. From this viewpoint, a conservative approach is applied because biogas contains “only” approximately 60% of methane (in dependence on technology and processed material.

  2. Mission analysis report for single-shell tank leakage mitigation

    International Nuclear Information System (INIS)

    Cruse, J.M.

    1994-01-01

    This document provides an analysis of the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site's 149 single-shell high-level waste tanks. This mission is a part of the overall missions of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineers principles are being applied to this effort. Mission analysis supports early decision making by clearly defining program objectives. This documents identifies the initial conditions and acceptable final conditions, defines the programmatic and physical interfaces and constraints, estimates the resources to carry out the mission, and establishes measures of success. The results of the mission analysis provide a consistent basis for subsequent systems engineering work

  3. The root caused analysis of leakaged heat exchanger tube

    International Nuclear Information System (INIS)

    Shamsudin, Shaiful Rizam; Salleh, M.A.A. Mohd; Rahmat, Azmi; Anuar, Mohd Arif; Harun, Mohd; Zayid, Hafizal; Noor, Mazlee Mohd

    2015-01-01

    AISI type 316L stainless steel was used as a heat exchanger tube material in an inter-cooler column. After less than a year of operation, severe corrosion failures occurred and a transverse opening leakage was observed on one of the heat exchanger tubes. The failed tube was carefully analyzed using various metallurgical laboratory equipments. The root cause of the tube leakage was believed due to the presence of horizontal micro and macro pores as a hydrogen gas entrapment during casting of the parent ingot. The overlapped and gaping pores formed notch on the shell side of the tube surface, and it increasingly evident when the use of a high-energy water-jet and metal brush as cleaning procedure results in an establishment of pitting type local-action corrosion cells penetrated the tube wall. As a result, corrosive fluid in the tube side dissolved into the cooling water, accelerating the corrosion process.

  4. A software sampling frequency adaptive algorithm for reducing spectral leakage

    Institute of Scientific and Technical Information of China (English)

    PAN Li-dong; WANG Fei

    2006-01-01

    Spectral leakage caused by synchronous error in a nonsynchronous sampling system is an important cause that reduces the accuracy of spectral analysis and harmonic measurement.This paper presents a software sampling frequency adaptive algorithm that can obtain the actual signal frequency more accurately,and then adjusts sampling interval base on the frequency calculated by software algorithm and modifies sampling frequency adaptively.It can reduce synchronous error and impact of spectral leakage;thereby improving the accuracy of spectral analysis and harmonic measurement for power system signal where frequency changes slowly.This algorithm has high precision just like the simulations show,and it can be a practical method in power system harmonic analysis since it can be implemented easily.

  5. Remote laser detection of natural gas leakages from pipelines

    International Nuclear Information System (INIS)

    Petukhov, V O; Gorobets, V A; Andreev, Yu M; Lanskii, G V

    2010-01-01

    A differential absorption lidar based on a tunable TEA CO 2 laser emitting at 42 lines of the 'hot' 01 1 1 - 11 1 0 band in the range from 10.9 to 11.4 μm is developed for detecting natural gas leakages from oil pipelines by measuring the ethane content in the atmosphere. The ethane detection sensitivity is 0.9 ppm km. The presence of methane does not distort the measurement results. The developed lidar can detect the natural gas leakage from kilometre heights at the flying velocities up to 200 km h -1 and a probe pulse repetition rate of 5 Hz. (laser applications and other topics in quantum electronics)

  6. Model-Based Detection of Pipe Leakage at Joints

    International Nuclear Information System (INIS)

    Kim, Taejin; Youn, Byeng D.; Woo, Sihyong

    2015-01-01

    Time domain reflectometry (TDR) is widely used for wire failure detection. It transmits a pulse that is reflected at the boundaries of different characteristic impedances. By analyzing the reflected signal, TDR makes it possible to locate the failure. In this study, TDR was used to detect the water leakage at a pipe joint. A wire attached to the pipe surface was soaked by water when a leak occurred, which affected the characteristic impedance of the wet part, resulting in a change in the reflected signal. To infer the leakage from the TDR signal, we first developed a finite difference time domain-based forward model that provided the output of the TDR signal given the configuration of the transmission line. Then, by solving the inverse problem, the locations of the leaks were found

  7. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran (Univ. of Gaevle, Gaevle (Sweden)); Meijer, Jan-Erik; Rosqvist, Haakan (NSR AB, Helsingborg (Sweden))

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  8. Support calculations for management of PRISE leakage accidents

    Energy Technology Data Exchange (ETDEWEB)

    Matejovic, P; Vranka, L [Nuclear Power Plants Research Inst. Vuje, Trnava (Slovakia)

    1998-12-31

    Accidents involving primary-to-secondary leakage (PRISE) caused by rupture of one or a few tubes are well known design basis events in both, western and VVER NPPs. Operating experience and in-service inspections of VVER-440 units have demonstrated also the potential for large PRISE leaks in the case of the steam generator (SG) primary collector cover lift-up (Rovno NPP). Without performing any countermeasure for limitation of SG collector cover lift-up, a full opening results in PRISE leak with an equivalent diameter 107 mm. Although this accident was not considered in the original design, this event is usually analysed as DBA too. Different means are available for detection and mitigation of PRISE leakage in NPPs currently in operation (J.Bohunice V-1 and V-2) or under construction (Mochovce) in Slovakia. 8 refs.

  9. Practical implementation of a higher order transverse leakage approximation

    International Nuclear Information System (INIS)

    Prinsloo, Rian H.; Tomašević

    2011-01-01

    Transverse integrated nodal diffusion methods currently represent the standard in full core neutronic simulation. The primary shortcoming in this approach, be it via the Analytic Nodal Method or Nodal Expansion Method, is the utilization of the quadratic transverse leakage approximation. This approach, although proven to work well for typical LWR problems, is not consistent with the formulation of nodal methods and can cause accuracy and convergence problems. In this work an improved, consistent quadratic leakage approximation is formulated, which derives from the class of higher order nodal methods developed some years ago. In this new approach, only information relevant to describing the transverse leak- age terms in the zero-order nodal equations are obtained from the higher order formalism. The method yields accuracy comparable to full higher order methods, but does not suffer from the same computational burden which these methods typically incur. (author)

  10. Air leakage test of reactor hall using tracer technique

    International Nuclear Information System (INIS)

    Yang Yanqiu; Yang Liang; Yang Tongzai

    2011-01-01

    The leakage ratios of three related reactor halls were tested by sulfur hexafluoride gaseous tracer technique. Moreover, the accumulation intensities of leak gas and its retention time in some important working rooms, the crossroads of corridors and anteroom of the building were detected. The results show that the air leakage ratios of the three reactor halls are (7.30±0.16) x 10 -4 , (1.88±0.12) x 10 -4 and (2.07±0.07) x 10 -4 h -1 . The leak gas accumulates in all the detected working rooms fast, and the retention time to various rooms is about 5 h. The heaviest intensities are in the clothes change rooms on the first floor. However, the retention time to the crossroads and the anteroom is about 10 h, and the accumulation intensities are much small. (authors)

  11. Injection Technique and Pen Needle Design Affect Leakage From Skin After Subcutaneous Injections

    DEFF Research Database (Denmark)

    Præstmark, Kezia Ann; Stallknecht, Bente; Jensen, Morten Lind

    2016-01-01

    BACKGROUND: After a subcutaneous injection fluid might leak out of the skin, commonly referred to as leakage or backflow. The objective was to examine the influence of needle design and injection technique on leakage after injections in the subcutaneous tissue of humans and pigs. METHOD: Leakage ...

  12. Some possible causes and probability of leakages in LMFBR steam generators

    International Nuclear Information System (INIS)

    Bolt, P.R.

    1984-01-01

    Relevant operational experience with steam generators for process and conventional plant and thermal and fast reactors is reviewed. Possible causes of water/steam leakages into sodium/gas are identified and data is given on the conditions necessary for failure, leakage probability and type of leakage path. (author)

  13. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  14. CloudSafetyNet: Detecting Data Leakage between Cloud Tenants

    OpenAIRE

    Pietzuch, PR; Priebe, C; Muthukumaran, D; O'Keeffe, D; Eyers, D; Shand, B; Kapitza, R

    2014-01-01

    01.12.14 KB. Ok to add accepted version to spiral. Copyright ? 2014 by the Association for Computing Machinery, Inc. (ACM).When tenants deploy applications under the control of third-party cloud providers, they must trust the providers security mechanisms for inter-tenant isolation, resource sharing and access control. Despite a providers best efforts, accidental data leakage may occur due to misconfigurations or bugs in the cloud platform. Especially in Platform-as-a-Service (PaaS) clouds...

  15. Deforestation, Leakage and Avoided Deforestation Policies: A Spatial Analysis

    OpenAIRE

    Philippe Delacote; Elizabeth J. Z. Robinson; Sébastien Roussel

    2015-01-01

    This paper analyses the impact of several avoided deforestation policies within a patchy forested landscape. Central is the idea that one neighbour's deforestation actions may impact the returns to deforestation in nearby patches. We determine the impact of each policy in terms of avoided deforestation and leakage levels at the landscape scale through modelling and simulations. Avoided deforestation policies at a landscape level are respectively: two Payment for Environmental Services (PES) p...

  16. A code for leakage neutron spectra through thick shields

    International Nuclear Information System (INIS)

    Nagarajan, P.S.; Sethulakshmi, P.; Raghavendran, C.P.

    1975-01-01

    An exponential transform Monte Carlo code has been developed for deep penetration of neutrons and the results of leakage neutron spectra of this code have been compared with those of a basic Monte Carlo code for small thickness. The development of the code and optimisation of certain transform parameters are discussed and results are presented for a few thick shields of concrete and water in the context of neutron monitoring in the environs of accelerator and reactor shields. (author)

  17. The Technique to Prevent the Data Leakage using Covert Channels

    Directory of Open Access Journals (Sweden)

    Anna Vasilievna Arkhangelskaya

    2013-12-01

    Full Text Available The purpose of the article was to analyze technique to prevent information leakage using covert channels. The main steps are as follows: involving covert channels identification, data throughput estimation, its elimination or limitation, audit and detection. Three schemes of identification had been analyzed: shared resources methodology, covert flow tree method, message sequence diagram method. Ways of guarantee information delivery from systems with low security level to systems with high security level have been investigated.

  18. A decision support system for on-line leakage localization

    OpenAIRE

    Meseguer, Jordi; Mirats-Tur, Josep M.; Cembrano, Gabriela; Puig, Vicenç; Quevedo, Joseba; Pérez, Ramon; Sanz, Gerard; Ibarra, David

    2014-01-01

    This paper describes a model-driven decision-support system (software tool) implementing a model-based methodology for on-line leakage detection and localization which is useful for a large class of water distribution networks. Since these methods present a certain degree of complexity which limits their use to experts, the proposed software tool focuses on the integration of a method emphasizing its use by water network managers as a decision support system. The proposed software tool integr...

  19. Binding and leakage of barium in alginate microbeads.

    Science.gov (United States)

    Mørch, Yrr A; Qi, Meirigeng; Gundersen, Per Ole M; Formo, Kjetil; Lacik, Igor; Skjåk-Braek, Gudmund; Oberholzer, Jose; Strand, Berit L

    2012-11-01

    Microbeads of alginate crosslinked with Ca(2+) and/or Ba(2+) are popular matrices in cell-based therapy. The aim of this study was to quantify the binding of barium in alginate microbeads and its leakage under in vitro and accumulation under in vivo conditions. Low concentrations of barium (1 mM) in combination with calcium (50 mM) and high concentrations of barium (20 mM) in gelling solutions were used for preparation of microbeads made of high-G and high-M alginates. High-G microbeads accumulated barium from gelling solution and contained higher concentrations of divalent ions for both low- and high-Ba exposure compared with high-G microbeads exposed to calcium solely and to high-M microbeads for all gelling conditions. Although most of the unbound divalent ions were removed during the wash and culture steps, leakage of barium was still detected during storage. Barium accumulation in blood and femur bone of mice implanted with high-G beads was found to be dose-dependent. Estimated barium leakage relevant to transplantation to diabetic patients with islets in alginate microbeads showed that the leakage was 2.5 times lower than the tolerable intake value given by WHO for high-G microbeads made using low barium concentration. The similar estimate gave 1.5 times higher than is the tolerable intake value for the high-G microbeads made using high barium concentration. To reduce the risk of barium accumulation that may be of safety concern, the microbeads made of high-G alginate gelled with a combination of calcium and low concentration of barium ions is recommended for islet transplantation. Copyright © 2012 Wiley Periodicals, Inc.

  20. Exchange-Rate Unification with Black Market Leakages; Russia 1992

    OpenAIRE

    Linda S. Goldberg

    1993-01-01

    In 1992 Russia unified the multiple exchange rates that had applied to international transactions. This paper describes the multiple exchange rate system that existed in Russia prior to mid-1992 and undertakes a theoretical exploration of the effects of the exchange rate unification that took place in July 1992. The model developed here allows for leakages between official and black markets and permits flexibility of the exchange rates in both official and parallel currency markets. Within th...

  1. Artificial-Crack-Behavior Test Evaluation of the Water-Leakage Repair Materials Used for the Repair of Water-Leakage Cracks in Concrete Structures

    OpenAIRE

    Soo-Yeon Kim; Sang-Keun Oh; Byoungil Kim

    2016-01-01

    There are no existing standard test methods at home and abroad that can verify the performance of water leakage repair materials, and it is thus very difficult to perform quality control checks in the field of water leakage repair. This study determined that the key factors that have the greatest impact on the water leakage repair materials are the micro-behaviors of cracks, and proposed an artificial-crack-behavior test method for the performance verification of the repair materials. The per...

  2. Environmental and artificial tracers for investigating leakages into salt mines

    International Nuclear Information System (INIS)

    Zuber, A.; Grabczak, J.; Kolonko, M.

    1979-01-01

    The paper presents the results of five years of experience in investigating the origin of waters in the Wapno mine, where salt is exploited in a Zechstein dome, in northwestern Poland. Tritium and 14 C measurements showed young infiltration waters in leakages at the third level of the mine. Stable isotope determinations showed a considerable shift of values from the precipitation line, both on activity and on concentration scales. Despite this shift, it was possible to distinguish infiltration waters from connate ones appearing at deeper mine levels. In 1976 and 1977 leakage flow-rates increased and the mineralization decreased. Tritium and 14 C contents did not then change, showing that, at the initial stages of flooding, the origin of water in the leakages was not changed. The first results of isotope investigations in the Klodawa mine, situated in another Zechstein salt dome in central Poland, showed connate waters. Observations performed in the Wieliczka salt mine, situated in Miocene formations in southern Poland, showed old waters originating from the surrounding formations. Their stable isotope composition shows that recharge took place in a cooler climate. The 14 C content of these waters is 1 to 2% of recent carbon. The experimental procedure used to determine the isotopic composition of highly mineralized brines is also described. (author)

  3. Leakage losses from a hydraulic fracture and fracture propagation

    International Nuclear Information System (INIS)

    Johnson, R.E.; Gustafson, C.W.

    1988-01-01

    The fluid mechanics of viscous fluid injection into a fracture embedded in a permeable rock formation is studied. Coupling between flow in the fracture and flow in the rock is retained. The analysis is based on a perturbation scheme that assumes the depth of penetration of the fluid into the rock is small compared to the characteristic length w 3 0 /k, where w 0 is the characteristic crack width and k is the permeability. This restriction, however, is shown to be minor. The spatial dependence of the leakage rate per unit length from the fracture is found to be linear, decreasing from the well bore to the fracture tip where it vanishes. The magnitude of the leakage rate per unit length is found to decay in time as t -1 /sup // 3 if the injection rate at the well bore is constant, and as t -1 /sup // 2 if the well bore pressure is held constant. The results cast considerable doubt on the validity of Carter's well-known leakage formula (Drilling Prod. Prac. API 1957, 261) derived from a one-dimensional theory. Using the simple fracture propagation model made popular by Carter, the present work also predicts that the fracture grows at a rate proportional to t 1 /sup // 3 for a fixed well bore injection rate and a rate proportional to t 1 /sup // 4 for a fixed well bore pressure

  4. Mechanistic approach to the sodium leakage and fire analysis

    International Nuclear Information System (INIS)

    Yamaguchi, Akira; Muramatsu, Toshiharu; Ohira, Hiroaki; Ida, Masao

    1997-04-01

    In December 1995, a thermocouple well was broken and liquid sodium leaked out of the intermediate heat transport system of the prototype fast breeder reactor Monju. In the initiating process of the incident, liquid sodium flowed out through the hollow thermocouple well, nipple and connector. As a result, liquid sodium, following ignition and combustion, was dropping from the connector to colide with the duct and grating placed below. The collision may cause fragmentation and scattering of the sodium droplet that finally was piled up on the floor. This report deals with the development of computer programs for the phenomena based on mechanistics approach. Numerical analyses are also made for fundamental sodium leakage and combustion phenomenon, sodium combustion experiment, and Monju incident condition. The contents of this report is listed below: (1) Analysis of chemical reaction process based on molecular orbital method, (2) Thermalhy draulic analysis of the sodium combustion experiment II performed in 1996 at O-arai Engineering Center, PNC, (3) Thermalhy draulic analysis of room A-446 of Monju reactor when the sodium leakage took place, (4) Direct numerical simulation of sodium droplet, (5) Sodium leakage and scattering analysis using three dimensional particle method, (6) Multi-dimensional combustion analysis and multi-point approximation combustion analysis code. Subsequent to the development work of the programs, they are to be applied to the safety analysis of the Fast Breeder Reactor. (author)

  5. A Minimum Leakage Quasi-Static RAM Bitcell

    Directory of Open Access Journals (Sweden)

    Adam Teman

    2011-05-01

    Full Text Available As SRAMs continue to grow and comprise larger percentages of the area and power consumption in advanced systems, the need to minimize static currents becomes essential. This brief presents a novel 9T Quasi-Static RAM Bitcell that provides aggressive leakage reduction and high write margins. The quasi-static operation method of this cell, based on internal feedback and leakage ratios, minimizes static power while maintaining sufficient, albeit depleted, noise margins. This paper presents the concept of the novel cell, and discusses the stability of the cell under hold, read and write operations. The cell was implemented in a low-power 40 nm TSMC process, showing as much as a 12× reduction in leakage current at typical conditions, as compared to a standard 6T or 8T bitcell at the same supply voltage. The implemented cell showed full functionality under global and local process variations at nominal and low voltages, as low as 300 mV.

  6. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  7. Detection Test for Leakage of CO2 into Sodium Loop

    International Nuclear Information System (INIS)

    Park, Sun Hee; Wi, Myung-Hwan; Min, Jae Hong

    2015-01-01

    This report is about the facility for the detection test for leakage of CO 2 into sodium loop. The facility for the detection test for leakage of CO 2 into sodium loop was introduced. The test will be carried out. Our experimental results are going to be expected to be used for approach methods to detect CO 2 leaking into sodium in heat exchangers. A sodium-and-carbon dioxide (Na-CO 2 ) heat exchanger is one of the key components for the supercritical CO 2 Brayton cycle power conversion system of sodium-cooled fast reactors (SFRs). A printed circuit heat exchanger (PCHE) is considered for the Na-CO 2 heat exchanger, which is known to have potential for reducing the volume occupied by the exchangers compared to traditional shell-and-tube heat exchangers. Among various issues about the Na- CO 2 exchanger, detection of CO 2 leaking into sodium in the heat exchanger is most important thing for its safe operation. It is known that reaction products from sodium and CO 2 such as sodium carbonate (Na 2 CO 3 ) and amorphous carbon are hardly soluble in sodium, which cause plug sodium channels. Detection technique for Na 2 CO 3 in sodium loop has not been developed yet. Therefore, detection of CO 2 and CO from reaction of sodium and CO 2 are proper to detect CO 2 leakage into sodium loop

  8. Method of detecting water leakage in radioactive waste containing vessel

    International Nuclear Information System (INIS)

    Ishioka, Hitoshi; Takao, Yoshiaki; Hayakawa, Kiyoshige.

    1989-01-01

    Lower level radioactive wastes formed upon operation of nuclear facilities are processed by underground storage. In this case, a plurality of drum cans packed with radioactive wastes are contained in a vessel and a water soluble dye material is placed at the inside of the vessel. The method of placing the water soluble dye material at the inside of the vessel includes a method of coating the material on the inner surface of the vessel and a method of mixing the material in sands to be filled between each of the drum cans. Then, leakage of water soluble dye material is detected when water intruding from the outside into the vessel is again leached out of the vessel, to detect the water leakage from the inside of the vessel. In this way, it is possible to find a water-invaded vessel before corrosion of the drum can by water intruded into the vessel and leakage of nuclides in the drum can. Accordingly, it is possible to apply treatment such as repair before occurrence of accident and can maintain the safety of radioactive water processing facilities. (I.S.)

  9. Fail-safe first wall for preclusion of little leakage

    International Nuclear Information System (INIS)

    Shibui, Masanao; Nakahira, Masataka; Tada, Eisuke; Takatsu, Hideyuki

    1994-05-01

    Leakages although excluded by design measures would occur most probably in highly stressed areas, weldments and locations without possibility to classify the state by in-service inspection. In a water-cooled first wall, allowable leak rate of water is generally very small, and therefore, locating of the leak portion under highly activated environment will be very difficult and be time-consuming. The double-wall concept is promising for the ITER first wall, because it can be made fail-safe by the application of the leak-before-break and the multiple load path concepts, and because it has a potential capability to solve the little leak problem. When the fail safe strength is well defined, subcritical crack growth in the damaged wall can be permitted. This will enable to detect stable leakage of coolant without deteriorating plasma operation. The paper deals with the little leak problem and presents method for evaluating small leak rate of a liquid coolant from crack-like defects. The fail-safe first wall with the double-wall concept is also proposed for preclusion of little leakage and its fail-safety is discussed. (author)

  10. Leakage flow simulation in a specific pump model

    International Nuclear Information System (INIS)

    Dupont, P; Bayeul-Lainé, A C; Dazin, A; Bois, G; Roussette, O; Si, Q

    2014-01-01

    This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 8.06 code (RANS frozen and unsteady calculations). Comparisons between numerical and experimental results are presented and discussed for three flow rates. The performances of the diffuser obtained by numerical simulation results are compared to the performances obtained by three-hole probe indications. The comparisons show few influence of fluid leakage on global performances but a real improvement concerning the efficiency of the impeller, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up

  11. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  12. Sodium leakage experience at the prototype FBR Monju

    International Nuclear Information System (INIS)

    Miyakawa, A.; Maeda, H.; Kani, Y.; Ito, K.

    2000-01-01

    Monju is Japan's prototype fast breeder reactor: 280 MWe (714 MWt), fueled with mixed oxides of plutonium and uranium, cooled by liquid sodium. Construction was started in 1985 and initial criticality was attained in April 1994. On 8th December 1995, sodium leakage from a secondary circuit occurred in a piping room of the reactor auxiliary building. The secondary sodium leaked through a temperature sensor, due to the breakaway of the tip of the thermocouple well tube installed near the secondary circuit outlet of the intermediate heat exchanger (IHX). The reactor remained cooled and thus, from the viewpoint of radiological hazards, the safety of the reactor was secured. There was no release of radioactive material. There were no adverse effects for personnel and the surrounding environment. The thermocouple well tube failure resulted from high cycle fatigue due to flow induced vibration. It was found that this flow induced vibration was not caused by well-known Von Karman vortex shedding, but a symmetric vortex shedding. The design of the thermocouple well, which was subject to avoid this phenomenon, was reviewed. A new design guide against the flow-induced vibration was prepared by JNC (Japan Nuclear Cycle Development Institute). This is more comprehensive and definitive than the existing guide 'ASME N-1300' (Flow-induced vibration of tube and tube banks). New thermocouple well designs were proposed consistent with this design guide. To prevent a recurrence of the secondary sodium leakage incident, comprehensive design review activities were started for the purpose of checking the safety and reliability of the plant. As a result, several aspects to be improved were identified and improvements and countermeasures have been studied. The main improvements and countermeasures are as follows: To enable the operators to understand and react to incidents quickly, new sodium leakage detectors (TV monitors, smoke sensors) and a new surveillance system will be installed; To

  13. [Detection of marginal leakage of Class V restorations in vitro by micro-CT].

    Science.gov (United States)

    Gu, Lin-juan; Zhao, Xin-yi; Li, Shi-bao

    2012-09-01

    To evaluate the reliability and superiority of micro-CT in marginal leakage assessment of Class V restorations. Class V preparations with gingival margins in dentin and occlusal in enamel were made in sixteen extracted non-carious human molars and restored with dental bonding agents and composite resin. All teeth were then immersed in 50% ammonia-silver nitrate solution for 12 hours, followed by developing solution for 8 hours. Each restoration was scanned by a micro-CT and silver leakage was measured and three-dimensional image of the silver leakage alone cavity wall were reconstructed. Afterward, all restorations were sectioned and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by micro-CT and microscope were compared for equivalency. The silver leakage depths in gingival wall obtained with micro-CT (0.78 mm) and microscope (0.74 mm) showed no significant difference (P > 0.05), while the judgment of leakage depths in occlusal wall in micro-CT image (0.40 mm) was affected by adjacent enamel structure, giving less leakage depths compared to microscope (0.72 mm)(P leakages showed channels on their way to spreading. Micro-CT can detect precisely the silver leakage in the dentin wall of a restoration and display its three-dimensional shape fully. Enamel structure affects the detection of the silver leakage next to it.

  14. IMPACT OF DUCT LEAKAGE PRESSURES ON THE SHAPE OF THE DELTA Q CURVE

    International Nuclear Information System (INIS)

    Andrews, J.W.

    2002-01-01

    The question of whether and to what extent information on the pressures driving duct leaks can be extracted from the data taken during the Delta Q test for duct leakage is investigated. Curves of Delta Q vs. house pressure are generated for sets of cases where the supply and return leakage rates to/from outside are held constant while the leakage pressures are varied. It is found that the Delta Q curve takes on two qualitatively different shapes, one for leakage pressures within the range of house pressures used in the Delta Q test (i.e., -25 Pa to +25 Pa) and the other for leakage pressures well outside this range. These effects are seen in experimental data taken with leakage at known pressures. However, extracting the signal of the leakage pressure from the surrounding noise caused by random measurement variation is likely to be a difficult problem in many cases

  15. Leakage characterization of top select transistor for program disturbance optimization in 3D NAND flash

    Science.gov (United States)

    Zhang, Yu; Jin, Lei; Jiang, Dandan; Zou, Xingqi; Zhao, Zhiguo; Gao, Jing; Zeng, Ming; Zhou, Wenbin; Tang, Zhaoyun; Huo, Zongliang

    2018-03-01

    In order to optimize program disturbance characteristics effectively, a characterization approach that measures top select transistor (TSG) leakage from bit-line is proposed to quantify TSG leakage under program inhibit condition in 3D NAND flash memory. Based on this approach, the effect of Vth modulation of two-cell TSG on leakage is evaluated. By checking the dependence of leakage and corresponding program disturbance on upper and lower TSG Vth, this approach is validated. The optimal Vth pattern with high upper TSG Vth and low lower TSG Vth has been suggested for low leakage current and high boosted channel potential. It is found that upper TSG plays dominant role in preventing drain induced barrier lowering (DIBL) leakage from boosted channel to bit-line, while lower TSG assists to further suppress TSG leakage by providing smooth potential drop from dummy WL to edge of TSG, consequently suppressing trap assisted band-to-band tunneling current (BTBT) between dummy WL and TSG.

  16. A coupled approach for the three-dimensional simulation of pipe leakage in variably saturated soil

    Science.gov (United States)

    Peche, Aaron; Graf, Thomas; Fuchs, Lothar; Neuweiler, Insa

    2017-12-01

    In urban water pipe networks, pipe leakage may lead to subsurface contamination or to reduced waste water treatment efficiency. The quantification of pipe leakage is challenging due to inaccessibility and unknown hydraulic properties of the soil. A novel physically-based model for three-dimensional numerical simulation of pipe leakage in variably saturated soil is presented. We describe the newly implemented coupling between the pipe flow simulator HYSTEM-EXTRAN and the groundwater flow simulator OpenGeoSys and its validation. We further describe a novel upscaling of leakage using transfer functions derived from numerical simulations. This upscaling enables the simulation of numerous pipe defects with the benefit of reduced computation times. Finally, we investigate the response of leakage to different time-dependent pipe flow events and conclude that larger pipe flow volume and duration lead to larger leakage while the peak position in time has a small effect on leakage.

  17. Automated detection of leakage in fluorescein angiography images with application to malarial retinopathy.

    Science.gov (United States)

    Zhao, Yitian; MacCormick, Ian J C; Parry, David G; Leach, Sophie; Beare, Nicholas A V; Harding, Simon P; Zheng, Yalin

    2015-06-01

    The detection and assessment of leakage in retinal fluorescein angiogram images is important for the management of a wide range of retinal diseases. We have developed a framework that can automatically detect three types of leakage (large focal, punctate focal, and vessel segment leakage) and validated it on images from patients with malarial retinopathy. This framework comprises three steps: vessel segmentation, saliency feature generation and leakage detection. We tested the effectiveness of this framework by applying it to images from 20 patients with large focal leak, 10 patients with punctate focal leak, and 5,846 vessel segments from 10 patients with vessel leakage. The sensitivity in detecting large focal, punctate focal and vessel segment leakage are 95%, 82% and 81%, respectively, when compared to manual annotation by expert human observers. Our framework has the potential to become a powerful new tool for studying malarial retinopathy, and other conditions involving retinal leakage.

  18. Short-term effects of CO2 leakage on the soil bacterial community in a simulated gas leakage scenario

    Directory of Open Access Journals (Sweden)

    Jing Ma

    2017-11-01

    Full Text Available The technology of carbon dioxide (CO2 capture and storage (CCS has provided a new option for mitigating global anthropogenic emissions with unique advantages. However, the potential risk of gas leakage from CO2 sequestration and utilization processes has attracted considerable attention. Moreover, leakage might threaten soil ecosystems and thus cannot be ignored. In this study, a simulation experiment of leakage from CO2 geological storage was designed to investigate the short-term effects of different CO2 leakage concentration (from 400 g m−2 day−1 to 2,000 g m−2 day−1 on soil bacterial communities. A shunt device and adjustable flow meter were used to control the amount of CO2 injected into the soil. Comparisons were made between soil physicochemical properties, soil enzyme activities, and microbial community diversity before and after injecting different CO2 concentrations. Increasing CO2 concentration decreased the soil pH, and the largest variation ranged from 8.15 to 7.29 (p < 0.05. Nitrate nitrogen content varied from 1.01 to 4.03 mg/Kg, while Olsen-phosphorus and total phosphorus demonstrated less regular downtrends. The fluorescein diacetate (FDA hydrolytic enzyme activity was inhibited by the increasing CO2 flux, with the average content varying from 22.69 to 11.25 mg/(Kg h (p < 0.05. However, the increasing activity amplitude of the polyphenol oxidase enzyme approached 230%, while the urease activity presented a similar rising trend. Alpha diversity results showed that the Shannon index decreased from 7.66 ± 0.13 to 5.23 ± 0.35 as the soil CO2 concentration increased. The dominant phylum in the soil samples was Proteobacteria, whose proportion rose rapidly from 28.85% to 67.93%. In addition, the proportion of Acidobacteria decreased from 19.64% to 9.29% (p < 0.01. Moreover, the abundances of genera Methylophilus, Methylobacillus, and Methylovorus increased, while GP4, GP6 and GP7 decreased. Canonical correlation analysis

  19. Exploring the Cross-sectional Association between Transit-Oriented Development Zoning and Active Travel and Transit Usage in the United States, 2010-2014

    Directory of Open Access Journals (Sweden)

    Emily eThrun

    2016-06-01

    Full Text Available Background: In response to traditional zoning codes that contribute to car-dependent, sprawling, and disconnected neighborhoods, communities are reforming their land use laws to create pedestrian-friendly areas that promote physical activity. One such reform is the adoption of transit-oriented developments or districts (TODs. TODs are higher-density, compact, mixed use areas located around transit stops that are designed to encourage walking.Purpose: To identify the characteristics of communities that have adopted TODs in their land use laws and examine if communities that have included TODs in their zoning codes are more likely to have adults that commute by any form of active transportation (i.e., walking, biking, or public transportation or by using public transportation specifically.Methods: Zoning codes effective as of 2010 were obtained for a purposeful sample of the largest 3,914 municipal jurisdictions located in 473 of the most populous US counties and consolidated cities within 48 states and the District of Columbia. They were evaluated to determine whether they included TOD districts or regulations using a coding tool developed by the study team. Descriptive statistics together with t-tests and Pearson’s chi-squared independence test were used to compare characteristics of jurisdictions with and without TOD zoning. Multivariate linear regressions were used to compute the adjusted association between TOD zoning and taking public or active transportation to work.Results: Jurisdictions with TOD zoning were located more in the South and West than non-TOD jurisdictions and were more populous, higher income, more racially diverse, and younger. Jurisdictions with TOD zoning had significantly higher percentages of occupied housing with no vehicle than those without TOD zoning. TOD zoning was associated with significantly higher rates of public transportation to work (β=2.10, 95% CI=0.88, 3.32 and active transportation to work (β=2.48, 95

  20. Numerical investigation of the leakage behaviour of reinforced concrete walls

    International Nuclear Information System (INIS)

    Christoph Niklasch; Laurent Coudert; Gregory Heinfling; Chantal Hervouet; Benoit Masson; Nico Herrmann; Lothar Stempniewski

    2005-01-01

    Full text of publication follows: For the verification of nuclear power plant safety, the leakage behaviour of the containment walls is of decisive importance. Extreme temperatures well over the water boiling temperature accompanied by high internal pressures can occur during an severe accident. In case of cracks through the entire thickness of the containment wall, an air-steam-water mixture may be released. In order to improve the knowledge of the leakage behaviour through cracks during such abnormal occurrences an experimental setup was developed at IfMB and several tests with different parameters were performed. The details of the experimental facility and the performed tests will be described in a separate paper. To improve the understanding of the behaviour of the tested wall elements during the tests numerical simulations of the performed leakage experiments are necessary. Reliable numerical tools provide a basis for the transfer of the leakage behaviour from the tested specimens to the behaviour of whole containment structures. To address the task of developing tools for the numerical simulation of the leakage behaviour of reinforced containment structures, EDF and IfMB decided to cooperate. During this cooperation two different numerical approaches had been made basing on existing tools and models of EDF and IfMB. In the following sections a short overview about the two different models will be given. For the numerical investigation of the leakage phenomena IfMB used the commercial Finite-Element- Program ADINA with ADINA's capability to solve coupled fluid-structure-interaction (FSI) problems. For the investigation of the moving of the specimen and the change of the crack profiles during the tests, it is important to take into account the heating of the specimen by the fluid flowing through the cracks. This is done by an iterative calculation of the fluid model and the structural model of the specimen. The thermo-dynamic boundary conditions representing

  1. Simulations of hydraulic fracturing and leakage in sedimentary basins

    Energy Technology Data Exchange (ETDEWEB)

    Lothe, Ane Elisabeth

    2004-01-01

    Hydraulic fracturing and leakage of water through the caprock is described from sedimentary basin over geological time scale. Abnormal pressure accumulations reduce the effective stresses in the underground and trigger the initiation of hydraulic fractures. The major faults in the basin define these pressure compartments. In this Thesis, basin simulations of hydraulic fracturing and leakage have been carried out. A simulator (Pressim) is used to calculate pressure generation and dissipitation between the compartments. The flux between the compartments and not the flow within the compartments is modelled. The Griffith-Coulomb failure criterion determines initial failure at the top structures of overpressured compartments, whereas the frictional sliding criterion is used for reactivation along the same fractures. The minimum horizontal stress is determined from different formulas, and an empirical one seems to give good results compared to measured pressures and minimum horizontal stresses. Simulations have been carried out on two datasets; one covering the Halten Terrace area and one the Tune Field area in the northern North Sea. The timing of hydraulic fracturing and amount of leakage has been quantified in the studies from the Halten Terrace area. This is mainly controlled by the lateral fluid flow and the permeability of the major faults in the basin. Low fault permeability gives early failure, while high fault permeabilities results in no or late hydraulic fracturing and leakage from overpressured parts of the basin. In addition to varying the transmissibility of all faults in a basin, the transmissibility across individual faults can be varied. Increasing the transmissibility across faults is of major importance in overpressured to intermediately pressured areas. However, to obtain change in the flow, a certain pressure difference has to be the situation between the different compartments. The coefficient of internal friction and the coefficient of frictional

  2. Air-steam leakage through cracks in concrete

    International Nuclear Information System (INIS)

    Georges Nahas; Helene Simon

    2005-01-01

    Full text of publication follows: In the context of a severe accident in a Pressurised Water nuclear plant, the evaluation of the leakage rate through the containment wall remains a key point of the safety analysis, because it influences directly the consequences on the environment. During a severe accident, large amounts of steam could be released in the containment; internal pressure could rise beyond design limits causing cracks to appear in the internal concrete wall of the double-wall containment and fission products to leak towards the containment annulus. A research program led by the French Institute for Radiological Protection and Nuclear Safety aims to estimate this leakage. In the presence of cracks, most of the leak flows through them. Hence, a first phase of the program was to build a two-phase homogeneous model for the flow of an air-steam mixture through a idealized traversing crack, taking into account condensation phenomena, and considering crack openings from 25 μm to several hundred μm. A numerical model for the flow, coupled with heat transfer in the wall, was implemented in the Finite Element code CAST3M. This model was validated on a small scaled experiment which was made of two parallel glass plates. Comparison of the numerical and experimental results in this 'channel case' has shown good results for the total mass flow rate for channel openings greater than 100 μm. For the 50 μm opening the calculation gave a 50 % estimate of the experimental total mass flow rate. The second phase of the program is now to validate the model on cracks performed in a concrete specimen. In order to do so, we have simulated the experiment VK2/2 described in the article named 'Investigation of the leakage behavior of reinforced concrete walls' by N. Herrmann, C. Niklasch, M. Stegemann, L. Stempniewski. The reinforced concrete slab, 2.7 m long in the reinforcement direction and 1.2 m thick in the cracking direction, is placed in a mechanical set-up and an

  3. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  4. POWER BEAMING LEAKAGE RADIATION AS A SETI OBSERVABLE

    Energy Technology Data Exchange (ETDEWEB)

    Benford, James N. [Microwave Sciences, 1041 Los Arabis Lane, Lafayette, CA 94549 (United States); Benford, Dominic J., E-mail: jimbenford@gmail.com [NASA’s Goddard Space Flight Center, Observational Cosmology Laboratory, Greenbelt, MD 20771 (United States)

    2016-07-10

    The most observable leakage radiation from an advanced civilization may well be from the use of power beaming to transfer energy and accelerate spacecraft. Applications suggested for power beaming involve launching spacecraft to orbit, raising satellites to a higher orbit, and interplanetary concepts involving space-to-space transfers of cargo or passengers. We also quantify beam-driven launch to the outer solar system, interstellar precursors, and ultimately starships. We estimate the principal observable parameters of power beaming leakage. Extraterrestrial civilizations would know their power beams could be observed, and so could put a message on the power beam and broadcast it for our receipt at little additional energy or cost. By observing leakage from power beams we may find a message embedded on the beam. Recent observations of the anomalous star KIC 8462852 by the Allen Telescope Array (ATA) set some limits on extraterrestrial power beaming in that system. We show that most power beaming applications commensurate with those suggested for our solar system would be detectable if using the frequency range monitored by the ATA, and so the lack of detection is a meaningful, if modest, constraint on extraterrestrial power beaming in that system. Until more extensive observations are made, the limited observation time and frequency coverage are not sufficiently broad in frequency and duration to produce firm conclusions. Such beams would be visible over large interstellar distances. This implies a new approach to the SETI search: instead of focusing on narrowband beacon transmissions generated by another civilization, look for more powerful beams with much wider bandwidth. This requires a new approach for their discovery by telescopes on Earth. Further studies of power beaming applications should be performed, potentially broadening the parameter space of the observable features that we have discussed here.

  5. Contrast media for radiological examination in gastrointestinal tract leakage

    International Nuclear Information System (INIS)

    Ginai-Karamat, A.Z.

    1987-01-01

    The aim of this investigation has been to find a safe and suitable contrast medium (CM) for radiological evaluation of the gastrointestinal tract (GIT) in cases where leakage outside the GIT can be suspected. An experimental study was carried out to evaluate the reactions of various available CM in the bronchi and lungs, mediastinum, pleura and peritoneum of rats. The CM evaluated in the experimental study were, pure barium sulphate (without any additives), commercial barium sulphate (Micropaque, with additives), Dionosil, Hytrast, Gastrografin, Amipaque (in pleura Omnipaque) and Hexabrix. (Auth.)

  6. Failure/leakage predictions of concrete structures containing cracks

    International Nuclear Information System (INIS)

    Pan, Y.C.; Marchertas, A.H.; Kennedy, J.M.

    1984-06-01

    An approach is presented for studying the cracking and radioactive release of a reactor containment during severe accidents and extreme environments. The cracking of concrete is modeled as the blunt crack. The initiation and propagation of a crack are determined by using the maximum strength and the J-integral criteria. Furthermore, the extent of cracking is related to the leakage calculation by using a model developed by Rizkalla, Lau and Simmonds. Numerical examples are given for a three-point bending problem and a hypothetical case of a concrete containment structure subjected to high internal pressure during an accident

  7. Large Epiphrenic Diverticulum with Perforation and Leakage below the Diaphragm

    DEFF Research Database (Denmark)

    Brønserud, Majken Munk; Brenøe, Anne-Sofie; Eckardt, Jens

    2015-01-01

    contrast revealed contrast leakage near the minor curvature of the stomach. The following esophagogastroduodenoscopy demonstrated a giant dilatation of the esophagus, as well as a second esophageal lumen originating 25 cm from the incisors. The “false” lumen of the esophagus was located parallel...... to esophagus, ending blindly in a perforation below the diaphragm. The clinical presentation and the patient’s age make it most likely, that it was a long epiphrenic diverticulum of pulsion type. The patient was treated conservatively, discharged after 10 days and has been followed in our outpatient clinic...... for 8 months, until he died of aggressive pulmonary cancer....

  8. Pressure control for minimizing leakage in water distribution systems

    OpenAIRE

    Nourhan Samir; Rawya Kansoh; Walid Elbarki; Amr Fleifle

    2017-01-01

    In the last decades water resources availability has been a major issue on the international agenda. In a situation of worsening scarcity of water resources and the rapidly increasing of water demands, the state of water losses management is part of manâs survival on earth. Leakage in water supply networks makes up a significant amount, sometimes more than 70% of the total water losses. The best practices suggest that pressure management is one of the most effective way to reduce the amount o...

  9. Distributed fiber optic system for oil pipeline leakage detection

    Science.gov (United States)

    Paranjape, R.; Liu, N.; Rumple, C.; Hara, Elmer H.

    2003-02-01

    We present a novel approach for the detection of leakage in oil pipelines using methods of fiber optic distributed sensors, a presence-of-oil based actuator, and Optical Time Domain Reflectometry (OTDR). While the basic concepts of our approach are well understood, the integration of the components into a complete system is a real world engineering design problem. Our focus has been on the development of the actuator design and testing using installed dark fiber. Initial results are promising, however environmental studies into the long term effects of exposure to the environment are still pending.

  10. Lightweight space radiator with leakage control by internal electrostatic fields

    International Nuclear Information System (INIS)

    Kim, H.; Bankoff, S.G.; Miksis, M.J.

    1991-01-01

    An electrostatic liquid film space radiator is proposed. This will employ an internal electrostatic field to prevent leakage of the liquid-metal coolant out of a puncture. This overcomes the major disadvantage of membrane radiators, which is their vulnerability to micrometeorite impacts. Calculations show that leaks of liquid lithium at 700 degree K can easily be stopped from punctures which are several mm in diameter, with very large safety factors. The basic idea lends itself to a variety of radiator concepts, both rotating and non-rotating. Some typical film thickness and pressure calculations in the presence of an electric field are shown

  11. Threats of Password Pattern Leakage Using Smartwatch Motion Recognition Sensors

    Directory of Open Access Journals (Sweden)

    Jihun Kim

    2017-06-01

    Full Text Available Thanks to the development of Internet of Things (IoT technologies, wearable markets have been growing rapidly. Smartwatches can be said to be the most representative product in wearable markets, and involve various hardware technologies in order to overcome the limitations of small hardware. Motion recognition sensors are a representative example of those hardware technologies. However, smartwatches and motion recognition sensors that can be worn by users may pose security threats of password pattern leakage. In the present paper, passwords are inferred through experiments to obtain password patterns inputted by users using motion recognition sensors, and verification of the results and the accuracy of the results is shown.

  12. [Endoscopic endonasal detection of cerebrospinal fluid leakage with topical fluorescein].

    Science.gov (United States)

    Sato, Taku; Kishida, Yugo; Watanabe, Tadashi; Tani, Akiko; Tada, Yasuhiro; Tamura, Takamitsu; Ichikawa, Masahiro; Sakuma, Jun; Omori, Koichi; Saito, Kiyoshi

    2013-08-01

    We evaluated the effectiveness of intraoperative topical application of fluorescein to detect the leakage point of cerebrospinal fluid(CSF)rhinorrhea. Three patients with CSF rhinorrhea were treated with an endoscopic endonasal technique. Ten percent fluorescein was topically used for intraoperative localization of the leak site. A change of the fluorescein color from brown to green due to dilation of CSF were recognized as evidence of CSF rhinorrhea. We repeated the procedure to detect any small defects. All CSF rhinorrheas were successfully repaired by this endoscopic endonasal approach. Topical application of fluorescein is simple and sensitive for identifying intraoperative CSF rhinorrhea.

  13. Early localization of containment leakage during an accident

    International Nuclear Information System (INIS)

    Pepin, P.; Chauliac, C.; Libmann, M.; Martinez, J.M.

    1990-01-01

    In case of an accident in a nuclear plant, checking the containment leaktightness would be a fundamental step for the diagnosis and prognosis of the radiological consequences. Significant help in this task can be provided by softwares. For that purpose, the French Atomic Energy Commission (CEA) is developing an expert system which can provide early in the accident a classification of the possible leakage paths and help understanding the necessary corrections which have to be undertaken by the utility. This software will be used at the Emergency Technical Center of the CEA. Its basic principles are described in this paper

  14. Artificial-Crack-Behavior Test Evaluation of the Water-Leakage Repair Materials Used for the Repair of Water-Leakage Cracks in Concrete Structures

    Directory of Open Access Journals (Sweden)

    Soo-Yeon Kim

    2016-09-01

    Full Text Available There are no existing standard test methods at home and abroad that can verify the performance of water leakage repair materials, and it is thus very difficult to perform quality control checks in the field of water leakage repair. This study determined that the key factors that have the greatest impact on the water leakage repair materials are the micro-behaviors of cracks, and proposed an artificial-crack-behavior test method for the performance verification of the repair materials. The performance of the 15 kinds of repair materials that are currently being used in the field of water leakage repair was evaluated by applying the proposed test method. The main aim of such a test method is to determine if there is water leakage by injecting water leakage repair materials into a crack behavior test specimen with an artificial 5-mm crack width, applying a 2.5 mm vertical behavior load at 100 cycles, and applying 0.3 N/mm2 constant water pressure. The test results showed that of the 15 kinds of repair materials, only two effectively sealed the crack and thus stopped the water leakage. The findings of this study confirmed the effectiveness of the proposed artificial-crack-behavior test method and suggest that it can be used as a performance verification method for checking the responsiveness of the repair materials being used in the field of water leakage repair to the repetitive water leakage behaviors that occur in concrete structures. The study findings further suggest that the use of the proposed test method makes it possible to quantify the water leakage repair quality control in the field.

  15. Studies of axial-leakage simulations for homogeneous and heterogeneous EBR-II core configurations

    International Nuclear Information System (INIS)

    Grimm, K.N.; Meneghetti, D.

    1985-08-01

    When calculations of flux are done in less than three dimensions, leakage-absorption cross sections are normally used to model leakages (flows) in the dimensions for which the flux is not calculated. Since the neutron flux is axially dependent, the leakages, and hence the leakage-absorption cross sections, are also axially dependent. Therefore, to obtain axial flux profiles (or reaction rates) for individual subassemblies, an XY-geometry calculation delineating each subassembly has to be done at several axial heights with space- and energy-dependent leakage-absorption cross sections that are appropriate for each height. This report discusses homogeneous and heterogeneous XY-geometry calculations at various axial locations and using several differing assumptions for the calculation of the leakage-absorption cross section. The positive (outward) leakage-absorption cross sections are modeled as actual leakage absorptions, but the negative (inward) leakage-absorption cross sections are modeled as either negative leakage absorptions (+-B 2 method) or positive downscatter cross sections [the Σ/sub s/(1 → g) method]. 3 refs., 52 figs., 10 tabs

  16. Application Of The Climafor Baseline To Determine Leakage: TheCase Of Scolel Te.

    Energy Technology Data Exchange (ETDEWEB)

    De Jong, B.H.J.; Bazan, E. Esquivel; Quechulpa Montalvo, S.

    2007-06-01

    The acceptance of forestry-based project activities tomitigate greenhouse gases emissions has been subjected to a number ofmethodological questions to be answered, of which the most challengingare baseline establishment and identification of and measuring leakage.Here we pose hypotheses for and quantify leakage of the Scolel Te projectin Chiapas, Mexico. In this project small-scale farmers are implementingforestry, agroforestry, and forest conservation activities, with carbonsequestration as one of the goals. The main leakage monitoring domain isdefined as the area owned by the participating farmers or communitiesoutside the area where the specific project activities take place. Thenull-hypothesis (no leakage) is that non-project land owned by the farmeror community will experience the same carbon stock changes as predictedby the regional baseline, specifically developed for the project. Firstwe assessed the most likely causes and sources of leakage that may occurin the project. From this analysis, one type of leakage seems to beimportant, i.e., activity shifting. Second we estimated the leakage of asample of participating farmers and communities. Actual land use was thencompared with expected land use derived from the baseline. The Plan Vivoof each participant, complemented with readily available tools toidentify the main sources and drivers of leakage are used to developsimple leakage assessment procedures, as demonstrated in this paper.Negative leakage was estimated to be negligible in this study.Incorporating these procedures already in the project planning stage willreduce the uncertainties related to the actual carbon mitigationpotential of any forestry project.

  17. Heterogeneous neutron-leakage model for PWR pin-by-pin calculation

    International Nuclear Information System (INIS)

    Li, Yunzhao; Zhang, Bin; Wu, Hongchun; Shen, Wei

    2017-01-01

    Highlights: •The derivation of the formula of the leakage model is introduced. This paper evaluates homogeneous and heterogeneous leakage models used in PWR pin-by-pin calculation. •The implements of homogeneous and heterogeneous leakage models used in pin-cell homogenization of the lattice calculation are studied. A consistent method of cooperation between the heterogeneous leakage model and the pin-cell homogenization theory is proposed. •Considering the computational cost, a new buckling search scheme is proposed to reach the convergence faster. The computational cost of the newly proposed neutron balance scheme is much less than the power-method scheme and the linear-interpolation scheme. -- Abstract: When assembly calculation is performed with the reflective boundary condition, a leakage model is usually required in the lattice code. The previous studies show that the homogeneous leakage model works effectively for the assembly homogenization. However, it becomes different and unsettled for the pin-cell homogenization. Thus, this paper evaluates homogeneous and heterogeneous leakage models used in pin-by-pin calculation. The implements of homogeneous and heterogeneous leakage models used in pin-cell homogenization of the lattice calculation are studied. A consistent method of cooperation between the heterogeneous leakage model and the pin-cell homogenization theory is proposed. Considering the computational cost, a new buckling search scheme is proposed to reach the convergence faster. For practical reactor-core applications, the diffusion coefficients determined by the transport cross-section or by the leakage model are compared with each other to determine which one is more accurate for the Pressurized Water Reactor pin-by-pin calculation. Numerical results have demonstrated that the heterogeneous leakage model together with the diffusion coefficient determined by the heterogeneous leakage model would have the higher accuracy. The new buckling search

  18. Cement Leakage in Percutaneous Vertebral Augmentation for Osteoporotic Vertebral Compression Fractures: Analysis of Risk Factors.

    Science.gov (United States)

    Xie, Weixing; Jin, Daxiang; Ma, Hui; Ding, Jinyong; Xu, Jixi; Zhang, Shuncong; Liang, De

    2016-05-01

    The risk factors for cement leakage were retrospectively reviewed in 192 patients who underwent percutaneous vertebral augmentation (PVA). To discuss the factors related to the cement leakage in PVA procedure for the treatment of osteoporotic vertebral compression fractures. PVA is widely applied for the treatment of osteoporotic vertebral fractures. Cement leakage is a major complication of this procedure. The risk factors for cement leakage were controversial. A retrospective review of 192 patients who underwent PVA was conducted. The following data were recorded: age, sex, bone density, number of fractured vertebrae before surgery, number of treated vertebrae, severity of the treated vertebrae, operative approach, volume of injected bone cement, preoperative vertebral compression ratio, preoperative local kyphosis angle, intraosseous clefts, preoperative vertebral cortical bone defect, and ratio and type of cement leakage. To study the correlation between each factor and cement leakage ratio, bivariate regression analysis was employed to perform univariate analysis, whereas multivariate linear regression analysis was employed to perform multivariate analysis. The study included 192 patients (282 treated vertebrae), and cement leakage occurred in 100 vertebrae (35.46%). The vertebrae with preoperative cortical bone defects generally exhibited higher cement leakage ratio, and the leakage is typically type C. Vertebrae with intact cortical bones before the procedure tend to experience type S leakage. Univariate analysis showed that patient age, bone density, number of fractured vertebrae before surgery, and vertebral cortical bone were associated with cement leakage ratio (Pcement leakage are bone density and vertebral cortical bone defect, with standardized partial regression coefficients of -0.085 and 0.144, respectively. High bone density and vertebral cortical bone defect are independent risk factors associated with bone cement leakage.

  19. Detection and quantification of methane leakage from landfills

    Energy Technology Data Exchange (ETDEWEB)

    Ljungberg, Sven-Aake; Maartensson, Stig-Goeran [Univ. of Gaevle, Gaevle (Sweden); Meijer, Jan-Erik; Rosqvist, Haakan [NSR AB, Helsingborg (Sweden)

    2009-03-15

    The purpose of this project was to detect gas leakage and to measure and quantify methane emission from landfills using modern remote sensing techniques. In this project, a handheld laser instrument and an IR camera were used. The overall objective was to develop cost-effective methods for detecting and quantifying methane emissions from landfills. There are many methods available for measuring the methane concentration in air, both from close-up and from long distances. Combined with the use of a tracer gas, the methane emission from entire landfills can be measured relatively accurately. A number of methods are used to detect leakage from parts of landfill surfaces, but there are few methods for quantifying leakage from sub-zones. Field measurements with the laser instrument and the IR camera were carried out at seven Swedish landfills and two landfills in France. The investigated surfaces at the Swedish landfills were divided into different zones, such as top surface, slope, crest and toe of slope. The field measurements in France were taken over entire landfills. The methane emission varied between the different landfills in the project, and also between the different landfill zones. The results from repeated field measurements indicated that a landfill with a final cap and a successful gas recovery system produces barely measurable emissions. The weak points at a landfill are generally slopes, including crests and toes of slopes. Where the covering of the waste is inadequate, leakage often occurs at lift joints and in areas where waste protrudes through the cover. Other weak points are deficiencies in the gas recovery system. Leachate systems can lead landfill gas and thereby cause methane leakage. Along with wind velocity and variations in atmospheric pressure, moisture content in the ground is an important factor that affects methane emissions from landfill surfaces. Results from field measurements of the same feature/surface at different points in time and

  20. Secure Mobile Agent from Leakage-Resilient Proxy Signatures

    Directory of Open Access Journals (Sweden)

    Fei Tang

    2015-01-01

    Full Text Available A mobile agent can sign a message in a remote server on behalf of a customer without exposing its secret key; it can be used not only to search for special products or services, but also to make a contract with a remote server. Hence a mobile agent system can be used for electronic commerce as an important key technology. In order to realize such a system, Lee et al. showed that a secure mobile agent can be constructed using proxy signatures. Intuitively, a proxy signature permits an entity (delegator to delegate its signing right to another entity (proxy to sign some specified messages on behalf of the delegator. However, the proxy signatures are often used in scenarios where the signing is done in an insecure environment, for example, the remote server of a mobile agent system. In such setting, an adversary could launch side-channel attacks to exploit some leakage information about the proxy key or even other secret states. The proxy signatures which are secure in the traditional security models obviously cannot provide such security. Based on this consideration, in this paper, we design a leakage-resilient proxy signature scheme for the secure mobile agent systems.

  1. AN ADVANCED LEAKAGE SCHEME FOR NEUTRINO TREATMENT IN ASTROPHYSICAL SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Perego, A. [Institut für Kernphysik, Technische Universität Darmstadt, Schlossgartenstraße 2, D-64289 Darmstadt (Germany); Cabezón, R. M. [Physics Department, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland); Käppeli, R., E-mail: albino.perego@physik.tu-darmstadt.de [Seminar for Applied Mathematics, ETH Zürich, Rämistrasse 101, 8092 Zürich (Switzerland)

    2016-04-15

    We present an Advanced Spectral Leakage (ASL) scheme to model neutrinos in the context of core-collapse supernovae (CCSNe) and compact binary mergers. Based on previous gray leakage schemes, the ASL scheme computes the neutrino cooling rates by interpolating local production and diffusion rates (relevant in optically thin and thick regimes, respectively) separately for discretized values of the neutrino energy. Neutrino trapped components are also modeled, based on equilibrium and timescale arguments. The better accuracy achieved by the spectral treatment allows a more reliable computation of neutrino heating rates in optically thin conditions. The scheme has been calibrated and tested against Boltzmann transport in the context of Newtonian spherically symmetric models of CCSNe. ASL shows a very good qualitative and a partial quantitative agreement for key quantities from collapse to a few hundreds of milliseconds after core bounce. We have proved the adaptability and flexibility of our ASL scheme, coupling it to an axisymmetric Eulerian and to a three-dimensional smoothed particle hydrodynamics code to simulate core collapse. Therefore, the neutrino treatment presented here is ideal for large parameter-space explorations, parametric studies, high-resolution tests, code developments, and long-term modeling of asymmetric configurations, where more detailed neutrino treatments are not available or are currently computationally too expensive.

  2. Endoscopic Management of Bile Leakage after Liver Transplantation

    Science.gov (United States)

    Oh, Dongwook; Lee, Sung Koo; Song, Tae Jun; Park, Do Hyun; Lee, Sang Soo; Seo, Dong-Wan; Kim, Myung-Hwan

    2015-01-01

    Background/Aims Endoscopic retrograde cholangiopancreatography (ERCP) can be an effective treatment for bile leakage after liver transplantation. We evaluated the efficacy of endoscopic treatment in liver transplantation in patients who developed bile leaks. Methods Forty-two patients who developed bile leaks after liver transplantation were included in the study. If a bile leak was observed on ERCP, a sphincterotomy was performed, and a nasobiliary catheter was then inserted. If a bile leak was accompanied by a bile duct stricture, either the stricture was dilated with balloons, followed by nasobiliary catheter insertion across the bile duct stricture, or endoscopic retrograde biliary drainage was performed. Results In the bile leakage alone group (22 patients), endoscopic treatment was technically successful in 19 (86.4%) and clinically successful in 17 (77.3%) cases. Among the 20 patients with bile leaks with bile duct strictures, endoscopic treatment was technically successful in 13 (65.0%) and clinically successful in 10 (50.0%) cases. Among the 42 patients who underwent ERCP, technical success was achieved in 32 (76.2%) cases and clinical success was achieved in 27 (64.3%) cases. Conclusions ERCP is an effective and safe therapeutic modality for bile leaks after liver transplantation. ERCP should be considered as an initial therapeutic modality in post-liver transplantation patients. PMID:25717048

  3. Leakage current measurements on pixelated CdZnTe detectors

    International Nuclear Information System (INIS)

    Dirks, B.P.F.; Blondel, C.; Daly, F.; Gevin, O.; Limousin, O.; Lugiez, F.

    2006-01-01

    In the field of the R and D of a new generation hard X-ray cameras for space applications we focus on the use of pixelated CdTe or CdZnTe semiconductor detectors. They are covered with 64 (0.9x0.9 mm 2 ) or 256 (0.5x0.5 mm 2 ) pixels, surrounded by a guard ring and operate in the energy ranging from several keV to 1 MeV, at temperatures between -20 and +20 o C. A critical parameter in the characterisation of these detectors is the leakage current per pixel under polarisation (∼50-500 V/mm). In operation mode each pixel will be read-out by an integrated spectroscopy channel of the multi-channel IDeF-X ASIC currently developed in our lab. The design and functionality of the ASIC depends directly on the direction and value of the current. A dedicated and highly insulating electronics circuit is designed to automatically measure the current in each individual pixel, which is in the order of tens of pico-amperes. Leakage current maps of different CdZnTe detectors of 2 and 6 mm thick and at various temperatures are presented and discussed. Defect density diagnostics have been performed by calculation of the activation energy of the material

  4. Low standby leakage 12T SRAM cell characterisation

    Science.gov (United States)

    Yadav, Arjun; Nakhate, Sangeeta

    2016-09-01

    In this work, a low power and variability-aware static random access memory (SRAM) architecture based on a twelve-transistor (12T) cell is proposed. This cell obtains low static power dissipation due to a parallel global latch (G-latch) and storage latch (S-latch), along with a global wordline (GWL), which offer a high cell ratio and pull-up ratio for reliable read and write operations and a low cell ratio and pull-up ratio during idle mode to reduce the standby power dissipation. In the idle state, only the S-latch stores bits, while the G-latch is isolated from the S-latch and the GWL is deactivated. The leakage power consumption of the proposed SRAM cell is thereby reduced by 38.7% compared to that of the conventional six-transistor (6T) SRAM cell. This paper evaluates the impact of the chip supply voltage and surrounding temperature variations on the standby leakage power and observes considerable improvement in the power dissipation. The read/write access delay, read static noise margin (SNM) and write SNM were evaluated, and the results were compared with those of the standard 6T SRAM cell. The proposed cell, when compared with the existing cell using the Monte Carlo method, shows an appreciable improvement in the standby power dissipation and layout area.

  5. MR images of rupture and leakage of breast implants

    International Nuclear Information System (INIS)

    Fang Ling; Liu Pengcheng; Huang Rong; Hu Huaxin; Chen Zaizhong; Du Duanming; Liu Hanqiao; Feng Fei

    2002-01-01

    Objective: To investigate the diagnostic value of magnetic resonance imaging in detecting rupture and leakage of breast implants. Methods: Seventeen cases with breast implants were imaged by MR scanner. 1 normal silicone breast implant outside the body was scanned by MR as an consultative standard. MR images of silicone implants and polypropylene acyl amine implants were classified and analyzed. Results: In 7 cases, 12 single lumen silicone implants were intact, among them 8 were silicone gel-filled implants, 4 were physiological saline-filled implants. 2 physiological saline-filled implants ruptured, among them 1 belonged to intracapsular silicone implant rupture with subsided silicone gel capsule which presented as long T 1 signal and short T 2 signal on MR images; The other belonged to extracapsular silicone implant rapture with physiological saline granule outside breast on MR images. 20 breast implants in 10 cases were injected by polypropylene acyl amine, among them 2 breast implants were intact, 16 breast implants ruptured completely with pieces and nodes of long T 1 signal and long T 2 signal on MR images, 14 of 16 also presented polypropylene acyl amine granule outside breast; 2 breast implants splited inside with linguine sign. Conclusion: The magnetic resonance imaging can make clear the type and the seat of breast implants, the type of rupture of breast implants, and the distribution of leakage material. Therefore magnetic resonance imaging can be an effective guidance for clinical operation and can be an consultative standard for follow-up

  6. Rapid measurement of blood leakage during regional chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, C. (Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. fuer Nuklearmedizin); Omlor, G.; Gross, G.; Feifel, G. (Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. fuer Allgemeine Chirurgie); Berberich, R. (Staedtische Klinik Wuppertal (Germany). Abt. fuer Nuklearmedizin)

    1993-03-01

    A method using technetium-99m in vivo red blood cell (RBC) labelling is reported that provides results within 3 min. Blood samples drawn from the systemic and the extracorporeal circulation were measured for [sup 99m]Tc activity using a mobile well counter, and the leakage values calculated. The mean result was 7.6%[+-]6.5%/15 min (n=209). The corresponding flow rate was 100.2[+-]85.7 ml/15 min. The values for isolation perfusion of the upper and the lower extremities are compared. The leakage results using [sup 99m]Tc RBC labelling were correlated with other blood pool markers. Iodine-125 human serum albumin and indium-113 m transferrin were administered in subgroups of 4 and 19 patients simultaneously. Using linear regression, the coefficient of correlation was 0.72 for [sup 99m]Tc/[sup 113m]In and 0.58 for [sup 99m]Tc/[sup 125]I. Comparison with the alternatives suggests that the method can be considered one of the most practicable and reliable methods available. (orig.).

  7. Plasma membrane damage detected by nucleic acid leakage

    International Nuclear Information System (INIS)

    Fortunati, E.; Bianchi, V.

    1989-01-01

    Among the indicators of membrane damage, the leakage of intracellular components into the medium is the most directly related to the perturbations of the membrane molecular organization. The extent of the damage can be evaluated from the size of the released components. We have designed a protocol for the detection of membrane leakage based on the preincubation of cells with tritiated adenine for 24 h, followed by a 24-h chase in nonradioactive medium. The treatment takes place when the distribution of the precursor among its end products has reached the plateau, and thus the differences of radioactivity in the fractions obtained from the control and treated cultures (medium, nucleotide pool, RNA, DNA) correspond to actual quantitative variations induced by the test chemical. Aliquots of the medium are processed to determine which percentage of the released material is macromolecular, in order to distinguish between mild and severe membrane damage. The origin of the extracellular radioactivity can be recognized from the variations of RNA counts in the treated cells. DNA radioactivity is used to evaluate the number of cells that remain attached to the plates in the different conditions of treatment. By this means, generalized permeabilization of membranes to macromolecules is distinguished from complete solubilization of only a subpopulation of cells. We present some examples of application of the protocol with detergents (LAS, SDS, Triton X-100) and with Cr(VI), which damages cell membranes by a different mechanism of action

  8. Uncertainty Analysis of In leakage Test for Pressurized Control Room Envelop

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. B. [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    In leakage tests for control room envelops(CRE) of newly constructed nuclear power plants are required to prove the control room habitability. Results of the in leakage tests should be analyzed using an uncertainty analysis. Test uncertainty can be an issue if the test results for pressurized CREs show low in leakage. To have a better knowledge of the test uncertainty, a statistical model for the uncertainty analysis is described here and a representative uncertainty analysis of a sample in leakage test is presented. A statistical method for analyzing the uncertainty of the in leakage test is presented here and a representative uncertainty analysis of a sample in leakage test was performed. By using the statistical method we can evaluate the test result with certain level of significance. This method can be more helpful when the difference of the two mean values of the test result is small.

  9. A study on two phase flows of linear compressors for the prediction of refrigerant leakage

    International Nuclear Information System (INIS)

    Hwang, Il Sun; Lee, Young Lim; Oh, Won Sik; Park, Kyeong Bae

    2015-01-01

    Usage of linear compressors is on the rise due to their high efficiency. In this paper, leakage of a linear compressor has been studied through numerical analysis and experiments. First, nitrogen leakage for a stagnant piston with fixed cylinder pressure as well as for a moving piston with fixed cylinder pressure was analyzed to verify the validity of the two-phase flow analysis model. Next, refrigerant leakage of a linear compressor in operation was finally predicted through 3-dimensional unsteady, two phase flow CFD (Computational fluid dynamics). According to the research results, the numerical analyses for the fixed cylinder pressure models were in good agreement with the experimental results. The refrigerant leakage of the linear compressor in operation mainly occurred through the oil exit and the leakage became negligible after about 0.4s following operation where the leakage became lower than 2.0x10 -4 kg/s.

  10. Uncertainty Analysis of In leakage Test for Pressurized Control Room Envelop

    International Nuclear Information System (INIS)

    Lee, J. B.

    2013-01-01

    In leakage tests for control room envelops(CRE) of newly constructed nuclear power plants are required to prove the control room habitability. Results of the in leakage tests should be analyzed using an uncertainty analysis. Test uncertainty can be an issue if the test results for pressurized CREs show low in leakage. To have a better knowledge of the test uncertainty, a statistical model for the uncertainty analysis is described here and a representative uncertainty analysis of a sample in leakage test is presented. A statistical method for analyzing the uncertainty of the in leakage test is presented here and a representative uncertainty analysis of a sample in leakage test was performed. By using the statistical method we can evaluate the test result with certain level of significance. This method can be more helpful when the difference of the two mean values of the test result is small

  11. Investigation of pool thermal hydraulics and temperature distribution in inner vessel under mechanical seal leakage

    International Nuclear Information System (INIS)

    Abraham, Juby; Velusamy, K.; Selvaraj, P.

    2015-01-01

    The primary heat sink of prototype fast breeder reactor is a sodium pool which is partitioned into cold pool and hot pool. The inner vessel which separates the cold and hot pools is having penetrations for intermediate heat exchangers. The hot sodium from hot pool leaks into the cold pool through these penetrations and to reduce the leakage, mechanical seals are provided. Leakage of hot sodium into cold pool can lead to thermal stratification in the cold pool and also will affect the temperature distribution in inner vessel. 3-D CFD studies were performed focusing these features as a function of sodium leakage. The analyses indicate that the maximum temperature difference across the IV thickness is 65°C without any leakage of sodium. The temperature difference is found to decrease with increase in leakage through the seals. It is seen that a leakage of 2.5% is acceptable. (author)

  12. Helium/solid powder O-ring leakage correlation experiments using a radiotracer

    International Nuclear Information System (INIS)

    Bild, R.W.; Leisher, W.B.; Weissman, S.H.; Seya, M.

    1984-01-01

    UO 2 definitely leaked past the O-ring in three of the tests confirming the major results of the previous work. Continuous leakage at these levels may require additional precautions under present regulatory policies. The mechanism and the time and particle size dependence for the leakage are not known, but there is some indication leakage is more likely at low temperatures. It is possible leakage is due to movement of the O-ring during temperature or pressure cycling at the beginning or end of a test. The radiotracer method involves less labor and is much less susceptible to contamination than the previous method. Future work will investigate leakage past lubricated O-rings and time dependence of leakage. 1 reference, 1 table

  13. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology

    OpenAIRE

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective...

  14. The use of wavelet transform in oil conveying pipeline's leakage detection and location

    International Nuclear Information System (INIS)

    Han Jian; Wang Yongtao; Mu Haiwei

    2006-01-01

    This paper uses the negative press wave method basing on wavelet transform to detect the singularity point of the pressure signal of oil conveying pipeline and uses the detected singularity point to locate the leakage, this method has better effect in real applying. And this paper analyzes the merits and shortcomings of this method in detecting and locating the leakage of oil conveying pipeline, so it offers reference for studying weak leakage of oil conveying pipeline in the future. (authors)

  15. Incidental Detection of Urinary Leakage on FDG PET/CT Imaging for Staging of Gastric Cancer.

    Science.gov (United States)

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    A 71-year-old woman presented to the emergency department with right flank pain and dysuria. An abdominal CT scan detected a gastric malignancy and hydronephrosis with urinary leakage of the right kidney. Percutaneous nephrostomy was performed on the right kidney. F-FDG PET/CT for staging the gastric malignancy revealed additional urinary leakage of the contralateral kidney. The interest in this case is the incidental detection of unexpected urinary leakage during an oncologic assessment with FDG PET/CT.

  16. On leakage and seepage from geological carbon sequestration sites

    Energy Technology Data Exchange (ETDEWEB)

    Oldenburg, C.M.; Unger, A.J.A.; Hepple, R.P.; Jordan, P.D.

    2002-07-18

    Geologic carbon sequestration is one strategy for reducing the rate of increase of global atmospheric carbon dioxide (CO{sub 2} ) concentrations (IEA, 1997; Reichle, 2000). As used here, the term geologic carbon sequestration refers to the direct injection of supercritical CO{sub 2} deep into subsurface target formations. These target formations will typically be either depleted oil and gas reservoirs, or brine-filled permeable formations referred to here as brine formations. Injected CO{sub 2} will tend to be trapped by one or more of the following mechanisms: (1) permeability trapping, for example when buoyant supercritical CO{sub 2} rises until trapped by a confining caprock; (2) solubility trapping, for example when CO{sub 2} dissolves into the aqueous phase in water-saturated formations, or (3) mineralogic trapping, such as occurs when CO{sub 2} reacts to produce stable carbonate minerals. When CO{sub 2} is trapped in the subsurface by any of these mechanisms, it is effectively sequestered away from the atmosphere where it would otherwise act as a greenhouse gas. The purpose of this report is to summarize our work aimed at quantifying potential CO{sub 2} seepage due to leakage from geologic carbon sequestration sites. The approach we take is to present first the relevant properties of CO{sub 2} over the range of conditions from the deep subsurface to the vadose zone (Section 2), and then discuss conceptual models for how leakage might occur (Section 3). The discussion includes consideration of gas reservoir and natural gas storage analogs, along with some simple estimates of seepage based on assumed leakage rates. The conceptual model discussion provides the background for the modeling approach wherein we focus on simulating transport in the vadose zone, the last potential barrier to CO{sub 2} seepage (Section 4). Because of the potentially wide range of possible properties of actual future geologic sequestration sites, we carry out sensitivity analyses by

  17. Modeling of leakage currents in high-k dielectrics

    International Nuclear Information System (INIS)

    Jegert, Gunther Christian

    2012-01-01

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO 2 material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO 2 /TiN capacitor structures were suggested and problem areas that may

  18. Modeling of leakage currents in high-k dielectrics

    Energy Technology Data Exchange (ETDEWEB)

    Jegert, Gunther Christian

    2012-03-15

    Leakage currents are one of the major bottlenecks impeding the downscaling efforts of the semiconductor industry. Two core devices of integrated circuits, the transistor and, especially, the DRAM storage capacitor, suffer from the increasing loss currents. In this perspective a fundamental understanding of the physical origin of these leakage currents is highly desirable. However, the complexity of the involved transport phenomena so far has prevented the development of microscopic models. Instead, the analysis of transport through the ultra-thin layers of high-permittivity (high-k) dielectrics, which are employed as insulating layers, was carried out at an empirical level using simple compact models. Unfortunately, these offer only limited insight into the physics involved on the microscale. In this context the present work was initialized in order to establish a framework of microscopic physical models that allow a fundamental description of the transport processes relevant in high-k thin films. A simulation tool that makes use of kinetic Monte Carlo techniques was developed for this purpose embedding the above models in an environment that allows qualitative and quantitative analyses of the electronic transport in such films. Existing continuum approaches, which tend to conceal the important physics behind phenomenological fitting parameters, were replaced by three-dimensional transport simulations at the level of single charge carriers. Spatially localized phenomena, such as percolation of charge carriers across pointlike defects, being subject to structural relaxation processes, or electrode roughness effects, could be investigated in this simulation scheme. Stepwise a self-consistent, closed transport model for the TiN/ZrO{sub 2} material system, which is of outmost importance for the semiconductor industry, was developed. Based on this model viable strategies for the optimization of TiN/ZrO{sub 2}/TiN capacitor structures were suggested and problem areas

  19. Polarization leakage in epoch of reionization windows - II. Primary beam model and direction-dependent calibration

    Science.gov (United States)

    Asad, K. M. B.; Koopmans, L. V. E.; Jelić, V.; Ghosh, A.; Abdalla, F. B.; Brentjens, M. A.; de Bruyn, A. G.; Ciardi, B.; Gehlot, B. K.; Iliev, I. T.; Mevius, M.; Pandey, V. N.; Yatawatta, S.; Zaroubi, S.

    2016-11-01

    Leakage of diffuse polarized emission into Stokes I caused by the polarized primary beam of the instrument might mimic the spectral structure of the 21-cm signal coming from the epoch of reionization (EoR) making their separation difficult. Therefore, understanding polarimetric performance of the antenna is crucial for a successful detection of the EoR signal. Here, we have calculated the accuracy of the nominal model beam of Low Frequency ARray (LOFAR) in predicting the leakage from Stokes I to Q, U by comparing them with the corresponding leakage of compact sources actually observed in the 3C 295 field. We have found that the model beam has errors of ≤10 per cent on the predicted levels of leakage of ˜1 per cent within the field of view, I.e. if the leakage is taken out perfectly using this model the leakage will reduce to 10-3 of the Stokes I flux. If similar levels of accuracy can be obtained in removing leakage from Stokes Q, U to I, we can say, based on the results of our previous paper, that the removal of this leakage using this beam model would ensure that the leakage is well below the expected EoR signal in almost the whole instrumental k-space of the cylindrical power spectrum. We have also shown here that direction-dependent calibration can remove instrumentally polarized compact sources, given an unpolarized sky model, very close to the local noise level.

  20. Radiation-induced off-state leakage current in commercial power MOSFETs

    International Nuclear Information System (INIS)

    Dodd, Paul Emerson; Shaneyfelt, Marty Ray; Draper, Bruce Leroy; Felix, James Andrew; Schwank, James Ralph; Dalton, Scott Matthew

    2005-01-01

    The total dose hardness of several commercial power MOSFET technologies is examined. After exposure to 20 krad(SiO 2 ) most of the n- and p-channel devices examined in this work show substantial (2 to 6 orders of magnitude) increases in off-state leakage current. For the n-channel devices, the increase in radiation-induced leakage current follows standard behavior for moderately thick gate oxides, i.e., the increase in leakage current is dominated by large negative threshold voltage shifts, which cause the transistor to be partially on even when no bias is applied to the gate electrode. N-channel devices biased during irradiation show a significantly larger leakage current increase than grounded devices. The increase in leakage current for the p-channel devices, however, was unexpected. For the p-channel devices, it is shown using electrical characterization and simulation that the radiation-induced leakage current increase is related to an increase in the reverse bias leakage characteristics of the gated diode which is formed by the drain epitaxial layer and the body. This mechanism does not significantly contribute to radiation-induced leakage current in typical p-channel MOS transistors. The p-channel leakage current increase is nearly identical for both biased and grounded irradiations and therefore has serious implications for long duration missions since even devices which are usually powered off could show significant degradation and potentially fail.

  1. Modelling of Leakage Current Through Double Dielectric Gate Stack in Metal Oxide Semiconductor Capacitor

    International Nuclear Information System (INIS)

    Fatimah A Noor; Mikrajuddin Abdullah; Sukirno; Khairurrijal

    2008-01-01

    In this paper, we have derived analytical expression of leakage current through double barriers in Metal Oxide Semiconductor (MOS) capacitor. Initially, electron transmittance through the MOS capacitor was derived by including the coupling between the transverse and longitudinal energies. The transmittance was then employed to obtain leakage current through the double barrier. In this model, we observed the effect of electron velocity due to the coupling effect and the oxide thickness to the leakage current. The calculated results showed that the leakage current decreases as the electron velocity increases. (author)

  2. Single phase cascaded H5 inverter with leakage current elimination for transformerless photovoltaic system

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Jia, X.; Lu, Z.

    2016-01-01

    Leakage current reduction is one of the important issues for the transformelress PV systems. In this paper, the transformerless single-phase cascaded H-bridge PV inverter is investigated. The common mode model for the cascaded H4 inverter is analyzed. And the reason why the conventional cascade H4...... inverter fails to reduce the leakage current is clarified. In order to solve the problem, a new cascaded H5 inverter is proposed to solve the leakage current issue. Finally, the experimental results are presented to verify the effectiveness of the proposed topology with the leakage current reduction...... for the single-phase transformerless PV systems....

  3. Leakage Current Elimination of Four-Leg Inverter for Transformerless Three-Phase PV Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; He, Ran; Jian, Jiamin

    2016-01-01

    Eliminating the leakage current is one of the most important issues for transformerless three phase photovoltaic (PV) systems. In this paper, the leakage current elimination of a three-phase four-leg PV inverter is investigated. With the common mode loop model established, the generation mechanism...... of the leakage current is clearly identified. Different typical carrier-based modulation methods and their corresponding common mode voltages are discussed. A new modulation strategy with Boolean logic function is proposed to achieve the constant common mode voltage for the leakage current reduction. Finally...

  4. Estimation of leakage power and delay in CMOS circuits using parametric variation

    Directory of Open Access Journals (Sweden)

    Preeti Verma

    2016-09-01

    Full Text Available With the advent of deep-submicron technologies, leakage power dissipation is a major concern for scaling down portable devices that have burst-mode type integrated circuits. In this paper leakage reduction technique HTLCT (High Threshold Leakage Control Transistor is discussed. Using high threshold transistors at the place of low threshold leakage control transistors, result in more leakage power reduction as compared to LCT (leakage control transistor technique but at the scarifies of area and delay. Further, analysis of effect of parametric variation on leakage current and propagation delay in CMOS circuits is performed. It is found that the leakage power dissipation increases with increasing temperature, supply voltage and aspect ratio. However, opposite pattern is noticed for the propagation delay. Leakage power dissipation for LCT NAND gate increases up to 14.32%, 6.43% and 36.21% and delay decreases by 22.5%, 42% and 9% for variation of temperature, supply voltage and aspect ratio. Maximum peak of equivalent output noise is obtained as 127.531 nV/Sqrt(Hz at 400 mHz.

  5. Reanastomosis with Stapler in Duodenojejunal Junction Anastomosis Leakage: A Case Report

    Directory of Open Access Journals (Sweden)

    Ahmet Seker

    2013-04-01

    Full Text Available After anastomosis leakages, treatment of patient gets more difficult and mortality rates increase. At lower level gastrointestinal anastomosis leakages, because of always there is an ostomy alternative, digestion problems are seen lesser. But at upper level gastrointestinal system anastomosis leakages, when it is taken account of nutrient condition of patient, requirement of making anastomos increases. So moratlity rates increase. At this article we aimed to present a different technique that we administered on management of a patient who had duodenojejunal junction anastomosis leakage.

  6. Investigations of leakage mechanisms and its influences on a micro swing engine considering rarefaction effects

    International Nuclear Information System (INIS)

    Zhou, Xiong; Zhang, Zhenyu; Kong, Wenjun; Du, Ning

    2016-01-01

    Highlights: • Mechanisms of the leakage flow in different flow regimes have been studied. • The leakage flow regime and patterns in the micro swing engine are presented. • Slip on the walls has a larger effect on leakage flow with decreasing the gap. • Rarefaction effects on the engine performance have been investigated. - Abstract: Considering rarefaction effects, this paper investigated mechanisms of the clearance leakage and its influences on a micro swing engine for the micro power generation by employing three different flow models named as discrete velocity direction (DVD) model, Navier-Stokes equations with slip boundary conditions (NS-slip) and no-slip boundary conditions (NS-no slip). Using the DVD model, this paper firstly studied leakage mechanisms of a micro Couette-Poisueille flow. Factors which control the leakage in different regimes were obtained. Furthermore, the system-level predictions of the clearance leakage in the micro swing engine have been conducted by solving the Navier-Stokes equations. The leakage flow regime, patterns and characteristics were presented. Results by NS-slip and NS-no slip were compared to study the rarefaction effects. Finally, investigations of the engine size and the gap height on the engine performance have been conducted. The significance of the leakage in different engine size regimes was presented, and the results show that rarefaction effects affect the indicated thermal efficiency greatly with the decrease of the engine size scale.

  7. Detection of marginal leakage of Class V restorations in vitro by micro-computed tomography.

    Science.gov (United States)

    Zhao, X Y; Li, S B; Gu, L J; Li, Y

    2014-01-01

    This in vitro study evaluated the efficacy of micro-computed tomography (CT) in marginal leakage detection of Class V restorations. Standardized Class V preparations with cervical margins in dentin and occlusal margins in enamel were made in 20 extracted human molars and restored with dental bonding agents and resin composite. All teeth were then immersed in 50% ammoniacal silver nitrate solution for 12 hours, followed by a developing solution for eight hours. Each restoration was scanned by micro-CT, the depth of marginal silver leakage in the central scanning section was measured, and the three-dimensional images of the silver leakage around each restoration were reconstructed. Afterward, all restorations were cut through the center and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by the micro-CT and the microscope were compared for equivalency. The silver leakage depth in cervical walls observed by micro-CT and microscope showed no significant difference; however, in certain cases the judgment of leakage depth in the occlusal wall in micro-CT image was affected by adjacent enamel structure, providing less leakage depth than was observed with the microscope (pleakage around the Class V restorations with clear borders only in the dentin region. It can be concluded that micro-CT can detect nondestructively the leakage around a resin composite restoration in two and three dimensions, with accuracy comparable to that of the conventional microscope method in the dentin region but with inferior accuracy in the enamel region.

  8. Method of detecting leakage from geologic formations used to sequester CO.sub.2

    Science.gov (United States)

    White, Curt [Pittsburgh, PA; Wells, Arthur [Bridgeville, PA; Diehl, J Rodney [Pittsburgh, PA; Strazisar, Brian [Venetia, PA

    2010-04-27

    The invention provides methods for the measurement of carbon dioxide leakage from sequestration reservoirs. Tracer moieties are injected along with carbon dioxide into geological formations. Leakage is monitored by gas chromatographic analyses of absorbents. The invention also provides a process for the early leak detection of possible carbon dioxide leakage from sequestration reservoirs by measuring methane (CH.sub.4), ethane (C.sub.2H.sub.6), propane (C.sub.3H.sub.8), and/or radon (Rn) leakage rates from the reservoirs. The invention further provides a method for branding sequestered carbon dioxide using perfluorcarbon tracers (PFTs) to show ownership.

  9. Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology.

    Science.gov (United States)

    Apperl, Benjamin; Pressl, Alexander; Schulz, Karsten

    2017-01-01

    The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective sheathing of the pipe; this paper aims at testing the feasibility of detecting leakages with temporary introduced fiber optic cable inside the pipe. The detection and localization were tested in a laboratory experiment. The intrusion of water from leakages into the pipe, producing a local temperature drop, served as indicator for leakages. Measurements were taken under varying measurement conditions, including the number of leakages as well as the positioning of the fiber optic cable. Experiments showed that leakages could be detected accurately with the proposed methodology, when measuring resolution, temperature gradient and measurement time were properly selected. Despite the successful application of DTS for leakage detection in this lab environment, challenges in real system applications may arise from temperature gradients within the pipe system over longer distances and the placement of the cable into the real pipe system.

  10. Detection of gaseous heavy water leakage points in CANDU 6 pressurized heavy water reactors

    International Nuclear Information System (INIS)

    Park, T-K.; Jung, S-H.

    1996-01-01

    During reactor operation, the heavy water filled primary coolant system in a CANDU 6 Pressurized Heavy Water (PHWR) may leak through routine operations of the plant via components, mechanical joints, and during inadvertent operations etc. Early detection of leak points is therefore important to maintain plant safety and economy. There are many independent systems to monitor and recover heavy water leakage in a CANDU 6 PHWR. Methodology for early detection based on operating experience from these systems, is investigated in this paper. In addition, the four symptoms of D 2 O leakage, the associated process for clarifying and verifying the leakage, and the probable points of leakage are discussed. (author)

  11. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D.; Shaffer, M.

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Warme und Feuchte instationar Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  12. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    Energy Technology Data Exchange (ETDEWEB)

    Prahl, D. [IBACOS, Inc., Pittsburgh, PA (United States); Shaffer, M. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Wärme und Feuchte instationär Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  13. Quench tank in-leakage diagnosis at St. Lucie

    Energy Technology Data Exchange (ETDEWEB)

    Price, J.E.; Au-Yang, M.K.; Beckner, D.A.; Vickery, A.N.

    1996-12-01

    In February 1995, leakage into the quench tank of the St. Lucie Nuclear Station Unit 1 was becoming an operational concern. This internal leak resulted in measurable increases in both the temperature and level of the quench tank water, and was so severe that, if the trend continued, plant shut down would be necessary. Preliminary diagnosis based on in-plant instrumentation indicated that any one of 11 valves might be leaking into the quench tank. This paper describes the joint effort by two teams of engineers--one from Florida Power & Light, the other from Framatome Technologies--to identify the sources of the leak, using the latest technology developed for valve diagnosis.

  14. Neutron leakage measurements from a medical linear accelerator

    International Nuclear Information System (INIS)

    Palta, J.R.; Hogstrom, K.R.; Tannanonta, C.

    1984-01-01

    The McCall method has been used to measure neutron leakage from the Mevatron 77, 18- and 15-MV photon beams. Gold foil activation has been used employing a beta counting technique for the 18-MV beam and a gamma counting technique for both the 18- and 15-MV beam. The two counting techniques were used to evaluate their relative merit. The measurements were made at various locations in the patient-treatment plane for different field sizes. The results show that the thermal-neutron dose equivalent contributes only about 1%--2% of the total neutron dose equivalent. At 100 cm, the neutron dose equivalent for the 18-MV beam is approximately six times that of the 15-MV beam, slightly exceeding the 0.1% of the useful beam criteria used by some of the regulatory agencies. In light of the uncertainty in fluence to dose equivalent conversion factors, the increased dose equivalent above 0.1% is insignificant

  15. BH2201 type leakage monitoring equipment of reactor fuel elements

    International Nuclear Information System (INIS)

    Ji Changsong; Dai Zhude; Xie Liangnian; Zhang Shulan; Zhang Shuheng

    1999-01-01

    A high-sensitive equipment monitoring leakage of the reactor fuel elements has been developed. The delayed neutrons emitted from fission product-pioneer nucleus are monitored in the 1st circle water. An array of 3 He proportional counter tubes is designed as a neutron detector for delayed neutrons, the detection geometry of which is near to 4π. In order to reduce the influence of interference factors the monitoring of fission product is carried out with 75s delay. The 87 Br delayed neutron pioneer nucleus is chosen as a monitoring object. The neutron detection efficiency of the developed equipment is 6.1%, which is 3 times higher than one of all available advanced equipment of the same function both at home and abroad

  16. A rare disease mimics postoperative bile leakage: Invasive aspergillosis.

    Science.gov (United States)

    Yazar, Fatih Mehmet; Urfalıoğlu, Aykut; Boran, Ömer Faruk; Sayar, Hamide; Kanat, Burhan Hakan; Emre, Arif; Cengiz, Emrah; Bülbüloğlu, Ertan

    2016-09-01

    Aspergillus fungi can cause serious infections, including intra-abdominal infection, particularly in patients with compromised immune system. Described in the present report is case of 46-year-old female patient who had undergone laparoscopic cholecystectomy (LC) at another healthcare facility. In early postoperative period, she had increasing complaints of swelling, nausea, and vomiting. On postoperative 19th day, she was referred to our clinic with diagnosis of acute abdomen. Surgery was performed with suspected possibility of bile leakage. However, pathological examination of soft, yellow-green mass found in subhepatic space determined it was fungus ball caused by fungi of the genus Aspergillus. Patient was diagnosed postoperative intra-abdominal aspergillosis (IAA).

  17. Gas leakage rate through reinforced concrete shear walls: Numerical study

    International Nuclear Information System (INIS)

    Wang Ting; Hutchinson, Tara C.

    2005-01-01

    Unlined reinforced concrete shear walls are often used as 'tertiary boundaries' in the United States Department of Energy (DOE) to house dangerous gases. An unanticipated event, such as an earthquake, may cause gases stored inside the walls to disperse into the environment resulting in excess pollution. To address this concern, in this paper, a methodology to numerically predict the gas leakage rate through these shear walls under lateral loading conditions is proposed. This methodology involves finite element and flow rate analysis. Strain distributions are obtained from the finite element analysis, and then used to simulate the crack characteristics on the concrete specimen. The flow rate through the damaged concrete specimen is then estimated using flow rate formulas available from the literature. Results from an experimental specimen are used to evaluate the methodology, and particularly its robustness in the flow rate estimation

  18. Probabilistic modeling of caprock leakage from seismic reflection data

    DEFF Research Database (Denmark)

    Zunino, Andrea; Hansen, Thomas Mejer; Bergjofd-Kitterød, Ingjerd

    We illustrate a methodology which helps to perform a leakage risk analysis for a CO2 reservoir based on a consistent, probabilistic approach to geophysical and geostatistical inversion. Generally, risk assessments of storage complexes are based on geological models and simulations of CO2 movement...... within the storage complexes. The geological models are built on top of geophysical data such as seismic surveys, geological information and well logs from the reservoir or nearby regions. The risk assessment of CO2 storage requires a careful analysis which accounts for all sources of uncertainty....... However, at present, no well-defined and consistent method for mapping the true uncertainty related to the geophysical data and how that uncertainty affects the overall risk assessment for the potential storage site is available. To properly quantify the uncertainties and to avoid unrealistic...

  19. Preliminary Study of Magnetic Flux Leakage on Tube Inspection

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Ilham Mukriz Zainal Abidin; Nurul Ain Ahmad Latif

    2015-01-01

    Magnetic Flux Leakage (MFL) is an advanced NDT technique which has the inspection capability in wall loss detection and measurement of sharp defects such as pitting, grooving and circumferential cracks in ferromagnetic samples. The working principle of MFL involves the induction of magnetic field in the part to be tested and the response or signal produced is analysed to determine the presence and characteristics of defects. In this paper, simulation and experimental work on wall loss detection in steel tube using MFL were carried out. The simulation was performed using Comsol software and followed by experimental work using MFL system for validation. The results from the simulation and experiment indicates that variation of the groove defect affect the magnetisation and the output of the MFL signal is related to change of flux caused by the detection of wall loss. (author)

  20. Modern diagnostic systems for loose parts, vibration and leakage monitoring

    International Nuclear Information System (INIS)

    Kunze, U.

    1997-01-01

    The modern diagnostic systems for loose parts, vibration and leakage monitoring of Siemens marked improvements in signal detection, ease of operation, and the display of information. The paper gives an overview on: Loose parts monitoring system KUeS '95 - a computer-based system. The knowledge and experience about loose parts detection incorporated into this system can be characterized as ''intelligence''. Vibration monitoring system SUeS '95 - a fully automated system for early detection of changes in the vibration patterns of the reactor coolant system components and reactor pressure vessel internals. Leak detection system FLUeS - a system that detects even small leaks in steam-carrying components and very accurately determines their location. Leaks are detected on the moisture distribution in a sample air column into which the escaping steam locally diffuses. All systems described represent the latest state of technology. Nevertheless a considerable amount of operational experience can be reported. (author). 5 refs, 10 figs

  1. Application of a leakage model to assess exfiltration from sewers.

    Science.gov (United States)

    Karpf, C; Krebs, P

    2005-01-01

    The exfiltration of wastewater from sewer systems in urban areas causes a deterioration of soil and possibly groundwater quality. Beside the simulation of transport and degradation processes in the unsaturated zone and in the aquifer the analysis of the potential impact requires the estimation of quantity and temporal variation of wastewater exfiltration. Exfiltration can be assessed by the application of a leakage model. The hydrological approach was originally developed to simulate the interactions between the groundwater and surface water, it was adapted to allow for modelling of interactions between groundwater and sewer system. In order to approximate the exfiltration specific model parameters infiltration specific parameters were used as a basis. Scenario analysis of the exfiltration in the City of Dresden from 1997 to 1999 and during the flood event in August 2002 shows the variation and the extent of exfiltration rates.

  2. A Labview Based Leakage Current Monitoring System For HV Insulators

    Directory of Open Access Journals (Sweden)

    N. Mavrikakis

    2015-10-01

    Full Text Available In this paper, a Labview based leakage current monitoring system for High Voltage insulators is described. The system uses a general purpose DAQ system with the addition of different current sensors. The DAQ system consists of a chassis and hot-swappable modules. Through the proper design of current sensors, low cost modules operating with a suitable input range can be employed. Fully customizable software can be developed using Labview, allowing on-demand changes and incorporation of upgrades. Such a system provides a low cost alternative to specially designed equipment with the added advantage of maximum flexibility. Further, it can be modified to satisfy the specifications (technical and economical set under different scenarios. In fact, the system described in this paper has already been installed in the HV Lab of the TEI of Crete whereas a variation of it is currently in use in TALOS High Voltage Test Station.

  3. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Horomichi

    1990-01-01

    The purpose of this study is to estimate the availability of acoustic method for detecting the internal leakage of valves at power plants. Experiments have been carried out on the characteristics of acoustic noise caused by the leak simulated flow. From the experimental results, the mechanism of the acoustic noisegenerated from flow, the relation between acoustic intensity and leak flow velocity, and the characteristics of the acoustic frequency spectrum were clarified. The acoustic method was applied to valves at site, and the background noises were measured in abnormal plant conditions. When the background level is higher than the acoustic signal, the difference between the background noise frequency spectrum and the acoustic signal spectrum provide a very useful leak detection method. (author)

  4. A nationwide study on anastomotic leakage after colonic cancer surgery

    DEFF Research Database (Denmark)

    Krarup, Peter-Martin; Jorgensen, L N; Andreasen, A H

    2012-01-01

    Aim: Anastomotic leakage (AL) is a major challenge in colorectal cancer surgery due to increased morbidity and mortality. Possible risk factors should be investigated differentially, distinguishing between rectal and colonic surgery in large-scale studies to avoid selection bias and confounding....... Method: The incidence and risk factors associated with AL were analysed in an unselected nation-wide prospective cohort of patient subjected to curative colonic cancer surgery with primary anastomosis and entered into The Danish Colorectal Cancer Group database between May 2001 and December 2008. Results......: AL occurred in 593 (6.4%) of 9333 patients. Laparoscopic surgery (odds ratio [OR], 1.34; 95% confidence interval [CI], 1.05-1.70; P = 0.03); left hemicolectomy (OR, 2.02; 95% CI, 1.50-2.72) or sigmoid colectomy (OR, 1.69; 95% CI, 1.32-2.17; P = 0.01); intraoperative blood loss (OR, 1.04; 95% CI, 1...

  5. Program for stator winding leakage inductance determination by FEA

    Directory of Open Access Journals (Sweden)

    Olivian Chiver

    2009-05-01

    Full Text Available This paper presents a program designed by the author in order to determine the stator winding parameters. The program is realized in Visual Basic and, in fact, it is for computer aided design of AC machines. Starting from the design data, based on the classical analytical formulas, geometrical parameters of the stator and the parameters of the stator winding are computed. This program works with a finite elements analysis (FEA software (the one used by the author is MagNet, a product of Infolytica company and according to data obtained after the design calculation, or according to data specified by user (in case of an existing machine, the stator and stator winding are built 3D (three-dimensional. For the same stator, different types of winding can be chosen. After realizing numerical model, by 3D FEA, leakage inductance is determined.

  6. A Study of Neutron Leakage in Finite Objects

    Science.gov (United States)

    Wilson, John W.; Slaba, Tony C.; Badavi, Francis F.; Reddell, Brandon D.; Bahadori, Amir A.

    2015-01-01

    A computationally efficient 3DHZETRN code capable of simulating High charge (Z) and Energy (HZE) and light ions (including neutrons) under space-like boundary conditions with enhanced neutron and light ion propagation was recently developed for simple shielded objects. Monte Carlo (MC) benchmarks were used to verify the 3DHZETRN methodology in slab and spherical geometry, and it was shown that 3DHZETRN agrees with MC codes to the degree that various MC codes agree among themselves. One limitation in the verification process is that all of the codes (3DHZETRN and three MC codes) utilize different nuclear models/databases. In the present report, the new algorithm, with well-defined convergence criteria, is used to quantify the neutron leakage from simple geometries to provide means of verifying 3D effects and to provide guidance for further code development.

  7. Quench tank in-leakage diagnosis at St. Lucie

    International Nuclear Information System (INIS)

    Price, J.E.; Au-Yang, M.K.; Beckner, D.A.; Vickery, A.N.

    1996-01-01

    In February 1995, leakage into the quench tank of the St. Lucie Nuclear Station Unit 1 was becoming an operational concern. This internal leak resulted in measurable increases in both the temperature and level of the quench tank water, and was so severe that, if the trend continued, plant shut down would be necessary. Preliminary diagnosis based on in-plant instrumentation indicated that any one of 11 valves might be leaking into the quench tank. This paper describes the joint effort by two teams of engineers--one from Florida Power ampersand Light, the other from Framatome Technologies--to identify the sources of the leak, using the latest technology developed for valve diagnosis

  8. Securing the best performance entitlement from MFL (Magnetic Flus Leakage)

    Energy Technology Data Exchange (ETDEWEB)

    Mullin, Ian P. [GE Oil and Gas, PII Pipeline Solutions, Stutensee (Germany)

    2009-07-01

    Magnetic Flux Leakage (MFL) tools are used to inspect around 70-80% of pipelines in the world, and the art of designing these tools has been established over the past 40 years. This paper investigates the science behind the art, and describes the fundamentals of MFL magnetiser design, focusing on the effects that various design options have on magnetic performance. Comparisons are drawn between a magnetiser bar design (hereafter referenced as 'magbar') and solid core bristle design (hereafter referenced as 'sweep's brush') including variations upon each. The study was carried out through the combined use of Vector Fields 3D and 2D finite element modelling and analysis software. (author)

  9. [A mobile sensor for remote detection of natural gas leakage].

    Science.gov (United States)

    Zhang, Shuai; Liu, Wen-qing; Zhang, Yu-jun; Kan, Rui-feng; Ruan, Jun; Wang, Li-ming; Yu, Dian-qiang; Dong, Jin-ting; Han, Xiao-lei; Cui, Yi-ben; Liu, Jian-guo

    2012-02-01

    The detection of natural gas pipeline leak becomes a significant issue for body security, environmental protection and security of state property. However, the leak detection is difficult, because of the pipeline's covering many areas, operating conditions and complicated environment. A mobile sensor for remote detection of natural gas leakage based on scanning wavelength differential absorption spectroscopy (SWDAS) is introduced. The improved soft threshold wavelet denoising was proposed by analyzing the characteristics of reflection spectrum. And the results showed that the signal to noise ratio (SNR) was increased three times. When light intensity is 530 nA, the minimum remote sensitivity will be 80 ppm x m. A widely used SWDAS can make quantitative remote sensing of natural gas leak and locate the leak source precisely in a faster, safer and more intelligent way.

  10. Colorectal anastomotic leakage: aspects of prevention, detection and treatment.

    Science.gov (United States)

    Daams, Freek; Luyer, Misha; Lange, Johan F

    2013-04-21

    All colorectal surgeons are faced from time to time with anastomotic leakage after colorectal surgery. This complication has been studied extensively without a significant reduction of incidence over the last 30 years. New techniques of prevention, by innovative anastomotic techniques should improve results in the future, but standardization and "teachability" should be guaranteed. Risk scoring enables intra-operative decision-making whether to restore continuity or deviate. Early detection can lead to reduction in delay of diagnosis as long as a standard system is used. For treatment options, no firm evidence is available, but future studies could focus on repair and saving of the anastomosis on the one hand or anastomotical breakdown and definitive colostomy on the other hand.

  11. [Nuclear medicine diagnosis of pulmonary capillary protein leakage].

    Science.gov (United States)

    Creutzig, H; Sturm, J A; Schober, O; Nerlich, M L; Kant, C J

    1984-10-01

    Pulmonary extravascular albumin extravasation in patients with adult respiratory distress syndrome can be quantified with radionuclide techniques. While imaging procedures with a computerized gamma camera will allow reproducible ROIs, this will be the main limitation in nonimaging measurements with small scintillation probes. Repeated positioning by one operator results in a mean spatial variation of position of about 2 cm and a variation in count rate of 25%. For the estimation of PCPL the small probes must be positioned under scintigraphic control. Under these conditions the results of both techniques are identical. The upper limit of normal was estimated to be 1 x E-5/sec. The standard deviation of abnormal measurements was about 10%. The pulmonary capillary protein leakage can be quantified by radionuclide techniques with good accuracy, using the combination of imaging and nonimaging techniques.

  12. Review of leakage-flow-induced vibrations of reactor components

    International Nuclear Information System (INIS)

    Mulcahy, T.M.

    1983-05-01

    The primary-coolant flow paths of a reactor system are usually subject to close scrutiny in a design review to identify potential flow-induced vibration sources. However, secondary-flow paths through narrow gaps in component supports, which parallel the primary-flow path, occasionally are the excitation source for significant vibrations even though the secondary-flow rates are orders of magnitude smaller than the primary-flow rate. These so-called leakage flow problems are reviewed here to identify design features and excitation sources that should be avoided. Also, design rules of thumb are formulated that can be employed to guide a design, but quantitative prediction of component response is found to require scale-model testing

  13. Application of the FFTBM method and the power relative contribution to the discharge transitory of the recirculation pumps of a BWR; Aplicacion del metodo FFTBM y de la contribucion relativa de potencia al transitorio de disparo de las bombas de recirculacion de un BWR

    Energy Technology Data Exchange (ETDEWEB)

    Castillo D, R.; Ortiz V, J.; Fuentes M, L., E-mail: rogelio.castillo@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    In this work was realized the simulation of the discharge transitory of both recirculation pumps of a BWR with the Simulate-3K code. This type of transitory is used in the stability analyses for the licensing of the fuel reload. An analysis of the precision of the simulation is also presented, using the FFTBM method jointly with the power relative contribution. This way, instead of determining the total precision of the calculation, a weighed precision is obtained by the contribution of each relevant parameter of the transitory. The results show that the precision of the simulation is acceptable due to the small magnitude of the merit figure of the width total average. The error in the merit figure comes mainly from the parameters total flow in the core and temperature of the fuel in the core. (Author)

  14. SETI VIA LEAKAGE FROM LIGHT SAILS IN EXOPLANETARY SYSTEMS

    International Nuclear Information System (INIS)

    Guillochon, James; Loeb, Abraham

    2015-01-01

    The primary challenge of rocket propulsion is the burden of needing to accelerate the spacecraft’s own fuel, resulting in only a logarithmic gain in maximum speed as propellant is added to the spacecraft. Light sails offer an attractive alternative in which fuel is not carried by the spacecraft, with acceleration being provided by an external source of light. By artificially illuminating the spacecraft with beamed radiation, speeds are only limited by the area of the sail, heat resistance of its material, and power use of the accelerating apparatus. In this paper, we show that leakage from a light sail propulsion apparatus in operation around a solar system analogue would be detectable. To demonstrate this, we model the launch and arrival of a microwave beam-driven light sail constructed for transit between planets in orbit around a single star, and find an optimal beam frequency on the order of tens of GHz. Leakage from these beams yields transients with flux densities of Jy and durations of tens of seconds at 100 pc. Because most travel within a planetary system would be conducted between the habitable worlds within that system, multiply transiting exoplanetary systems offer the greatest chance of detection, especially when the planets are in projected conjunction as viewed from Earth. If interplanetary travel via beam-driven light sails is commonly employed in our galaxy, this activity could be revealed by radio follow-up of nearby transiting exoplanetary systems. The expected signal properties define a new strategy in the search for extraterrestrial intelligence (SETI)

  15. SETI via Leakage from Light Sails in Exoplanetary Systems

    Science.gov (United States)

    Guillochon, James; Loeb, Abraham

    2015-10-01

    The primary challenge of rocket propulsion is the burden of needing to accelerate the spacecraft’s own fuel, resulting in only a logarithmic gain in maximum speed as propellant is added to the spacecraft. Light sails offer an attractive alternative in which fuel is not carried by the spacecraft, with acceleration being provided by an external source of light. By artificially illuminating the spacecraft with beamed radiation, speeds are only limited by the area of the sail, heat resistance of its material, and power use of the accelerating apparatus. In this paper, we show that leakage from a light sail propulsion apparatus in operation around a solar system analogue would be detectable. To demonstrate this, we model the launch and arrival of a microwave beam-driven light sail constructed for transit between planets in orbit around a single star, and find an optimal beam frequency on the order of tens of GHz. Leakage from these beams yields transients with flux densities of Jy and durations of tens of seconds at 100 pc. Because most travel within a planetary system would be conducted between the habitable worlds within that system, multiply transiting exoplanetary systems offer the greatest chance of detection, especially when the planets are in projected conjunction as viewed from Earth. If interplanetary travel via beam-driven light sails is commonly employed in our galaxy, this activity could be revealed by radio follow-up of nearby transiting exoplanetary systems. The expected signal properties define a new strategy in the search for extraterrestrial intelligence (SETI).

  16. Mind the gap - tip leakage vortex in axial turbines

    International Nuclear Information System (INIS)

    Dreyer, M; Farhat, M; Decaix, J; Münch-Alligné, C

    2014-01-01

    The tendency of designing large Kaplan turbines with a continuous increase of output power is bringing to the front the cavitation erosion issue. Due to the flow in the gap between the runner and the discharge ring, axial turbine blades may develop the so called tip leakage vortex (TLV) cavitation with negative consequences. Such vortices may interact strongly with the wake of guide vanes leading to their multiple collapses and rebounds. If the vortex trajectory remains close to the blade tip, these collapses may lead to severe erosion. One is still unable today to predict its occurrence and development in axial turbines with acceptable accuracy. Numerical flow simulations as well as the actual scale-up rules from small to large scales are unreliable. The present work addresses this problematic in a simplified case study representing TLV cavitation to better understand its sensitivity to the gap width. A Naca0009 hydrofoil is used as a generic blade in the test section of EPFL cavitation tunnel. A sliding mounting support allowing an adjustable gap between the blade tip and wall was manufactured. The vortex trajectory is visualized with a high speed camera and appropriate lighting. The three dimensional velocity field induced by the TLV is investigated using stereo particle image velocimetry. We have taken into account the vortex wandering in the image processing to obtain accurate measurements of the vortex properties. The measurements were performed in three planes located downstream of the hydrofoil for different values of the flow velocity, the incidence angle and the gap width. The results clearly reveal a strong influence of the gap width on both trajectory and intensity of the tip leakage vortex

  17. Mind the gap - tip leakage vortex in axial turbines

    Science.gov (United States)

    Dreyer, M.; Decaix, J.; Münch-Alligné, C.; Farhat, M.

    2014-03-01

    The tendency of designing large Kaplan turbines with a continuous increase of output power is bringing to the front the cavitation erosion issue. Due to the flow in the gap between the runner and the discharge ring, axial turbine blades may develop the so called tip leakage vortex (TLV) cavitation with negative consequences. Such vortices may interact strongly with the wake of guide vanes leading to their multiple collapses and rebounds. If the vortex trajectory remains close to the blade tip, these collapses may lead to severe erosion. One is still unable today to predict its occurrence and development in axial turbines with acceptable accuracy. Numerical flow simulations as well as the actual scale-up rules from small to large scales are unreliable. The present work addresses this problematic in a simplified case study representing TLV cavitation to better understand its sensitivity to the gap width. A Naca0009 hydrofoil is used as a generic blade in the test section of EPFL cavitation tunnel. A sliding mounting support allowing an adjustable gap between the blade tip and wall was manufactured. The vortex trajectory is visualized with a high speed camera and appropriate lighting. The three dimensional velocity field induced by the TLV is investigated using stereo particle image velocimetry. We have taken into account the vortex wandering in the image processing to obtain accurate measurements of the vortex properties. The measurements were performed in three planes located downstream of the hydrofoil for different values of the flow velocity, the incidence angle and the gap width. The results clearly reveal a strong influence of the gap width on both trajectory and intensity of the tip leakage vortex.

  18. SETI VIA LEAKAGE FROM LIGHT SAILS IN EXOPLANETARY SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Guillochon, James; Loeb, Abraham, E-mail: jguillochon@cfa.harvard.edu, E-mail: aloeb@cfa.harvard.edu [Harvard-Smithsonian Center for Astrophysics, The Institute for Theory and Computation, 60 Garden Street, Cambridge, MA 02138 (United States)

    2015-10-01

    The primary challenge of rocket propulsion is the burden of needing to accelerate the spacecraft’s own fuel, resulting in only a logarithmic gain in maximum speed as propellant is added to the spacecraft. Light sails offer an attractive alternative in which fuel is not carried by the spacecraft, with acceleration being provided by an external source of light. By artificially illuminating the spacecraft with beamed radiation, speeds are only limited by the area of the sail, heat resistance of its material, and power use of the accelerating apparatus. In this paper, we show that leakage from a light sail propulsion apparatus in operation around a solar system analogue would be detectable. To demonstrate this, we model the launch and arrival of a microwave beam-driven light sail constructed for transit between planets in orbit around a single star, and find an optimal beam frequency on the order of tens of GHz. Leakage from these beams yields transients with flux densities of Jy and durations of tens of seconds at 100 pc. Because most travel within a planetary system would be conducted between the habitable worlds within that system, multiply transiting exoplanetary systems offer the greatest chance of detection, especially when the planets are in projected conjunction as viewed from Earth. If interplanetary travel via beam-driven light sails is commonly employed in our galaxy, this activity could be revealed by radio follow-up of nearby transiting exoplanetary systems. The expected signal properties define a new strategy in the search for extraterrestrial intelligence (SETI)

  19. Regulatory analysis for the resolution of generic issue C---8, main steam isolation valve leakage and LCS [leakage control system] failure

    International Nuclear Information System (INIS)

    Graves, C.C.

    1990-06-01

    Generic Issue C-8 deals with staff concerns about public risk because of the incidence of leak test failures reported for main steam isolation valves (MSIVs) at boiling water reactors and the limitations of the leakage control systems (LCSs) for mitigating the consequences of leakage from these valves. If the MSIV leakage is greatly in excess of the allowable value in the technical specifications, the LCS would be unavailable because of design limitations. The issue was initiated in 1983 to assess (1) the causes of MSIV leakage failures, (2) the effectiveness of the LCS and alternative mitigation paths, and (3) the need for additional regulatory action to reduce public risk. This report presents the regulatory analysis for Generic Issue C-8 and concludes that no new regulatory requirements are warranted

  20. Air leakage control in chief tunnel of uranium mines using air screen

    International Nuclear Information System (INIS)

    Xiao Gengsheng

    1987-01-01

    In this paper the results of air leakage control are described using air screen in the chief tunnels of some uranium mines. The air leakage decreases by 79-91% after using air screen. On the basis of mathematical treatment, the formulas for calculating the air resistance efficiency of air screen are presented

  1. Neutron leakage from Pb and Bc spherical shells with 14 MeV central neutron source

    International Nuclear Information System (INIS)

    Antonov, S.; Daskalov, G.; Ilieva, K.; Jordanova, J.; Prodanova, R.; Zagryadskij, V.A.; Novikov, V.M.; Chuvilin, D.Yu.

    1988-01-01

    Results of measuring neutron leakage from spherical shells of different thickness, made of Pb and Be with a point neutron source in the sphere centrum are presented. The experiment results are compared to calculations according to different programs using data of various nuclear data libraies. The comparison has shown that all the calculations understate the neutron leakage from Pb assmebly. 9 refs.; 2 tabs

  2. REDD+ and international leakage via food and timber markets: a CGE analysis

    NARCIS (Netherlands)

    Kuik, O.J.

    2014-01-01

    This paper studies the effect of international trade in food and timber on land use and potential carbon leakage in the context of actions to reduce emissions from deforestation and forest degradation (REDD+). First a simple analytical model of international leakage is presented that focuses on

  3. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  4. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    Energy Technology Data Exchange (ETDEWEB)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H. [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH{sub T} was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle.

  5. Prevention through policy : Urban macroplastic leakages to the marine environment during extreme rainfall events

    NARCIS (Netherlands)

    Axelsson, Charles; van Sebille, Erik

    2017-01-01

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic

  6. The Analysis and Comparison of Leakage Inductance in Different Winding Arrangements for Planar Transformer

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Thomsen, Ole Cornelius; Andersen, Michael Andreas E.

    2009-01-01

    The coupling of the windings can be easily increased by using multiply stacked planar windings connection. Interleaving is a well-known technique used to reduce leakage inductance and minimize high-frequency winding losses. The paper aims to analyze leakage inductance based on magneto motive force...

  7. Hyperspectral indices for detecting changes in canopy reflectance as a result of underground natural gas leakage

    NARCIS (Netherlands)

    Noomen, M.F.; Smith, K.L.; Colls, J.J.; Steven, M.D.; Skidmore, A.K.; Meer, van der F.D.

    2008-01-01

    Natural gas leakage from underground pipelines is known to affect vegetation adversely, probably by displacement of the soil oxygen needed for respiration. This causes changes in plant and canopy reflectance, which may serve as indicators of gas leakage. In this study, a covariance analysis was

  8. Microvascular dysfunction with increased vascular leakage response in mice systemically exposed to arsenic.

    Science.gov (United States)

    Chen, Shih-Chieh; Huang, Shin-Yin; Lu, Chi-Yu; Hsu, Ya-Hung; Wang, Dean-Chuan

    2014-09-01

    The mechanisms underlying cardiovascular disease induced by arsenic exposure are not completely understood. The objectives of this study were to investigate whether arsenic-fed mice have an increased vascular leakage response to vasoactive agents and whether enhanced type-2 protein phosphatase (PP2A) activity is involved in mustard oil-induced leakage. ICR mice were fed water or sodium arsenite (20 mg/kg) for 4 or 8 weeks. The leakage response to vasoactive agents was quantified using the Evans blue (EB) technique or vascular labeling with carbon particles. Increased EB leakage and high density of carbon-labeled microvessels were detected in arsenic-fed mice treated with mustard oil. Histamine induced significantly higher vascular leakage in arsenic-fed mice than in water-fed mice. Pretreatment with the PP2A inhibitor okadaic acid or the neurokinin 1 receptor (NK1R) blocker RP67580 significantly reduced mustard oil-induced vascular leakage in arsenic-fed mice. The protein levels of PP2Ac and NK1R were similar in both groups. PP2A activity was significantly higher in the arsenic-fed mice compared with the control group. These findings indicate that microvessels generally respond to vasoactive agents, and that the increased PP2A activity is involved in mustard oil-induced vascular leakage in arsenic-fed mice. Arsenic may initiate endothelial dysfunction, resulting in vascular leakage in response to vasoactive agents.

  9. A conservation planning approach to mitigate the impacts of leakage from protected area networks.

    Science.gov (United States)

    Bode, Michael; Tulloch, Ayesha I T; Mills, Morena; Venter, Oscar; Ando, Amy W

    2015-06-01

    Protected area networks are designed to restrict anthropogenic pressures in areas of high biodiversity. Resource users respond by seeking to replace some or all of the lost resources from locations elsewhere in the landscape. Protected area networks thereby perturb the pattern of human pressures by displacing extractive effort from within protected areas into the broader landscape, a process known as leakage. The negative effects of leakage on conservation outcomes have been empirically documented and modeled using homogeneous descriptions of conservation landscapes. Human resource use and biodiversity vary greatly in space, however, and a theory of leakage must describe how this heterogeneity affects the magnitude, pattern, and biodiversity impacts of leakage. We combined models of household utility, adaptive human foraging, and biodiversity conservation to provide a bioeconomic model of leakage that accounts for spatial heterogeneity. Leakage had strong and divergent impacts on the performance of protected area networks, undermining biodiversity benefits but mitigating the negative impacts on local resource users. When leakage was present, our model showed that poorly designed protected area networks resulted in a substantial net loss of biodiversity. However, the effects of leakage can be mitigated if they are incorporated ex-ante into the conservation planning process. If protected areas are coupled with nonreserve policy instruments such as market subsidies, our model shows that the trade-offs between biodiversity and human well-being can be further and more directly reduced. © 2014 Society for Conservation Biology.

  10. Risk factors for leakage following intestinal anastomosis in dogs and cats: 115 cases (1991-2000).

    Science.gov (United States)

    Ralphs, S Christopher; Jessen, Carl R; Lipowitz, Alan J

    2003-07-01

    To identify factors associated with leakage following intestinal anastomosis in dogs and cats. Retrospective study. 90 dogs and 25 cats. Medical records of all dogs and cats that underwent intestinal resection and anastomosis between 1991 and 2000 were reviewed, and information on 27 factors was recorded. Anastomotic leakage was identified in 13 of the 90 dogs but in none of the 25 cats. Preoperative factors significantly associated with development of anastomotic leakage in dogs included preoperative peritonitis, serum albumin concentration, a left shift, and indication for surgery (dogs with intestinal foreign bodies were more likely to have leakage than dogs that underwent surgery for any other cause). Postoperative and case management factors significantly associated with development of leakage included duration of hospitalization, supplemental alimentation, whether the dog ate the day after surgery, blood product administration, and outcome (died vs survived). Discriminant analysis was performed, and dogs with 2 or more of the following factors were predicted to develop anastomotic leakage: preoperative peritonitis, intestinal foreign body, and serum albumin concentration dogs. Results suggest that a variety of factors may be associated with development of intestinal anastomotic leakage in dogs. In particular, dogs with 2 or more of the following risk factors are predicted to be at high risk for developing anastomotic leakage: preoperative peritonitis, intestinal foreign body, and serum albumin concentration < or = 2.5 g/dL.

  11. Estimation of Leakage Ratio Using Principal Component Analysis and Artificial Neural Network in Water Distribution Systems

    Directory of Open Access Journals (Sweden)

    Dongwoo Jang

    2018-03-01

    Full Text Available Leaks in a water distribution network (WDS constitute losses of water supply caused by pipeline failure, operational loss, and physical factors. This has raised the need for studies on the factors affecting the leakage ratio and estimation of leakage volume in a water supply system. In this study, principal component analysis (PCA and artificial neural network (ANN were used to estimate the volume of water leakage in a WDS. For the study, six main effective parameters were selected and standardized data obtained through the Z-score method. The PCA-ANN model was devised and the leakage ratio was estimated. An accuracy assessment was performed to compare the measured leakage ratio to that of the simulated model. The results showed that the PCA-ANN method was more accurate for estimating the leakage ratio than a single ANN simulation. In addition, the estimation results differed according to the number of neurons in the ANN model’s hidden layers. In this study, an ANN with multiple hidden layers was found to be the best method for estimating the leakage ratio with 12–12 neurons. This suggested approaches to improve the accuracy of leakage ratio estimation, as well as a scientific approach toward the sustainable management of water distribution systems.

  12. A severity-based quantification of data leakages in database systems

    NARCIS (Netherlands)

    Vavilis, S.; Petkovic, M.; Zannone, N.

    2016-01-01

    The detection and handling of data leakages is becoming a critical issue for organizations. To this end, data leakage solutions are usually employed by organizations to monitor network traffic and the use of portable storage devices. However, these solutions often produce a large number of alerts,

  13. Evaluation of the white test for the intraoperative detection of bile leakage.

    Science.gov (United States)

    Leelawat, Kawin; Chaiyabutr, Kittipong; Subwongcharoen, Somboon; Treepongkaruna, Sa-Ad

    2012-01-01

    We assess whether the White test is better than the conventional bile leakage test for the intraoperative detection of bile leakage in hepatectomized patients. This study included 30 patients who received elective liver resection. Both the conventional bile leakage test (injecting an isotonic sodium chloride solution through the cystic duct) and the White test (injecting a fat emulsion solution through the cystic duct) were carried out in the same patients. The detection of bile leakage was compared between the conventional method and the White test. A bile leak was demonstrated in 8 patients (26.7%) by the conventional method and in 19 patients (63.3%) by the White test. In addition, the White test detected a significantly higher number of bile leakage sites compared with the conventional method (Wilcoxon signed-rank test; P detection of bile leakage. Based on our study, we recommend that surgeons investigating bile leakage sites during liver resections should use the White test instead of the conventional bile leakage test.

  14. Oxygen-tension measurements - The first step towards prevention and early detection of anastomotic leakage

    NARCIS (Netherlands)

    Tanase, D.; French, P.J.; Komen, N.; Kleinrensink, G.J.; Jeekel, J.; Lange, J.F.; Draaijer, A.

    2007-01-01

    Many patients still die every year as a result of anastomotic leakage after surgery. The medical world needs an objective aid to detect leakage during surgery and during the critical recovery period. We propose a miniature measurement system to detect adequate tissue oxygenation pre- and

  15. A white-box anomaly-based framework for database leakage detection

    NARCIS (Netherlands)

    Costante, E.; den Hartog, J.; Petkovic, M.; Etalle, S.; Pechenizkiy, M.

    2017-01-01

    Data leakage is at the heart most of the privacy breaches worldwide. In this paper we present a white-box approach to detect potential data leakage by spotting anomalies in database transactions. We refer to our solution as white-box because it builds self explanatory profiles that are easy to

  16. Preoperative risk factors for anastomotic leakage after resection for colorectal cancer

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian; Gessler, B; Burcharth, Jakob

    2014-01-01

    AIM: Colorectal anastomotic leakage is a serious complication. Despite extensive research, no consensus on the most important preoperative risk factors exists. The aim of this systematic review and meta-analysis was to evaluate risk factors for anastomotic leakage in patients operated with colore...

  17. The extent of on-site leakage in selected suburbs of Johannesburg ...

    African Journals Online (AJOL)

    This study investigated on-site leakage on 182 properties with relatively new municipal water meters in well-established suburbs of Johannesburg. A methodology was developed to estimate the on-site leakage rate from readings taken from these municipal water meters, which was then adjusted to account for metering ...

  18. Effects of Chemistry Parameters of Primary Water affecting Leakage of Steam Generator Tube Cracks

    International Nuclear Information System (INIS)

    Shin, D. M.; Cho, N. C.; Kang, Y. S.; Lee, K. H.

    2016-01-01

    Degradation of steam generator (SG) tubes can affect pressure boundary tightness. As a defense-in-depth measure, primary to secondary leak monitoring program for steam generators is implemented, and operation is allowed under leakage limits in nuclear power plants. Chemistry parameters that affect steam generator tube leakage due to primary water stress corrosion cracking (PWSCC) are investigated in this study. Tube sleeves were installed to inhibit leakage and improve tube integrity as a part of maintenance methods. Steam generators occurred small leak during operation have been replaced with new steam generators according to plant maintenance strategies. The correlations between steam generator leakage and chemistry parameters are presented. Effects of primary water chemistry parameters on leakage from tube cracks were investigated for the steam generators experiencing small leak. Unit A experienced small leakage from steam generator tubes in the end of operation cycle. It was concluded that increased solubility of oxides due to high pHT could make leakage paths, and low boron concentration lead to less blockage in cracks. Increased dissolved hydrogen may retard crack propagations, but it did not reduce leak rate of the leaking steam generator. In order to inhibit and reduce leakage, pH_T was controlled by servicing cation bed operation. The test results of decreasing pHT indicate low pHT can reduce leak rate of PWSCC cracks in the end of cycle

  19. Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

    Science.gov (United States)

    Teverovsky, Alexander A.

    2016-01-01

    Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

  20. Leakage current analysis of single-phase transformer-less grid-connected PV inverters

    DEFF Research Database (Denmark)

    Ma, Lin; Kerekes, Tamas; Teodorescu, Remus

    2016-01-01

    Transformer-less string PV inverter is getting more and more widely utilized due to its higher efficiency, smaller volume and weight. However, without the galvanic isolation, the leakage current limitation and operation safety became the key issues of transformer-less inverters. This paper...... simplifies the leakage current generation circuit model and presents a leakage current estimation method both in real time and frequency domain. It shows that the leakage current is related to the circuit stray parameters, output filter and common mode voltage. Furthermore, with the proposed analysis method......, the leakage current generation of H-bridge with different modulation methods and HERIC inverter are discussed individually. At last, the presented method has been verified via simulation....

  1. Modeling the leakage of LCD displays with local backlight for quality assessment

    DEFF Research Database (Denmark)

    Mantel, Claire; Korhonen, Jari; Pedersen, Jesper M.

    2014-01-01

    The recent technique of local backlight dimming has a significant impact on the quality of images displayed with a LCD screen with LED local dimming. Therefore it represents a necessary step in the quality assessment chain, independently from the other processes applied to images. This paper...... investigates the modeling of one of the major spatial artifacts produced by local dimming: leakage. Leakage appears in dark areas when the backlight level is too high for LC cells to block sufficiently and the final displayed brightness is higher than it should. A subjective quality experiment was run...... on videos displayed on LCD TV with local backlight dimming viewed from a 0° and 15° angles. The subjective results are then compared objective data using different leakage models: constant over the whole display or horizontally varying and three leakage factor (no leakage, measured at 0° and 15...

  2. Anastomotic leakage after esophageal resection: new treatment options by endoluminal vacuum therapy.

    Science.gov (United States)

    Weidenhagen, Rolf; Hartl, Wolfgang H; Gruetzner, Klaus U; Eichhorn, Martin E; Spelsberg, Fritz; Jauch, Karl W

    2010-11-01

    Anastomotic leakage after esophagectomy is an important determinant of early and late morbidity and mortality. Control of the septic focus is essential when treating patients with anastomotic leakages. Surgical and endoscopic treatment options are limited. Between 2005 and 2009, we treated 6 patients who experienced an intrathoracic anastomotic leakage after esophageal resection. After all established therapeutic measures had failed, we explored the feasibility of an endoscopically assisted mediastinal vacuum therapy. We were able to heal intrathoracic esophageal leakages in all 6 patients without any local complications and without the need for reoperation. One patient died because of a progressive pneumonia. Endoscopic vacuum-assisted closure of anastomotic leakages may help to overcome the limitations that are associated with intermittent endoscopic treatment and conventional drainage therapy. Our preliminary results suggest that this new concept may be suitable for those patients. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Application of thermometric methods for detection and characterization of leakages in embankment dams

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Y.L.; Cunat, P.; Fry, J.J. [EDF, Grenoble (France); Faure, Y.H. [LTHE, Saint Martin d' Heres (France)

    2010-07-01

    The earliest possible detection of leakages in dikes is essential. Distributed temperature measurements using fibre optics allow the monitoring of large sections of the dike with a high spatial and temperature resolution. This paper presented the application of thermometric methods for detection and characterization of leakage in embankment dams. After a brief description of the system used, its application on a controlled experimental site and an EDF industrial site instrumented with fibre optics was presented. The instrumentation is complemented by installation of local temperature and pressure sensors in the piezometers for complete characterization of the detected leakages. The analysis of the results data clearly allowed detecting the leakages. The vertical location, intensity and location of the detected leakages were also identified. It was found that thermometry is potentially very powerful for detecting leaks and as a diagnostic tool.

  4. Prevention through policy: Urban macroplastic leakages to the marine environment during extreme rainfall events.

    Science.gov (United States)

    Axelsson, Charles; van Sebille, Erik

    2017-11-15

    The leakage of large plastic litter (macroplastics) into the ocean is a major environmental problem. A significant fraction of this leakage originates from coastal cities, particularly during extreme rainfall events. As coastal cities continue to grow, finding ways to reduce this macroplastic leakage is extremely pertinent. Here, we explore why and how coastal cities can reduce macroplastic leakages during extreme rainfall events. Using nine global cities as a basis, we establish that while cities actively create policies that reduce plastic leakages, more needs to be done. Nonetheless, these policies are economically, socially and environmentally cobeneficial to the city environment. While the lack of political engagement and economic concerns limit these policies, lacking social motivation and engagement is the largest limitation towards implementing policy. We recommend cities to incentivize citizen and municipal engagement with responsible usage of plastics, cleaning the environment and preparing for future extreme rainfall events. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  5. Pipeline leakage recognition based on the projection singular value features and support vector machine

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Wei; Zhang, Laibin; Mingda, Wang; Jinqiu, Hu [College of Mechanical and Transportation Engineering, China University of Petroleum, Beijing, (China)

    2010-07-01

    The negative wave pressure method is one of the processes used to detect leaks on oil pipelines. The development of new leakage recognition processes is difficult because it is practically impossible to collect leakage pressure samples. The method of leakage feature extraction and the selection of the recognition model are also important in pipeline leakage detection. This study investigated a new feature extraction approach Singular Value Projection (SVP). It projects the singular value to a standard basis. A new pipeline recognition model based on the multi-class Support Vector Machines was also developed. It was found that SVP is a clear and concise recognition feature of the negative pressure wave. Field experiments proved that the model provided a high recognition accuracy rate. This approach to pipeline leakage detection based on the SVP and SVM has a high application value.

  6. Signal-based Gas Leakage Detection for Fluid Power Accumulators in Wind Turbines

    DEFF Research Database (Denmark)

    Liniger, Jesper; Sepehri, Nariman; N. Soltani, Mohsen

    2017-01-01

    This paper describes the development and application of a signal-based fault detection method for identifying gas leakage in hydraulic accumulators used in wind turbines. The method uses Multiresolution Signal Decomposition (MSD) based on wavelets for feature extraction from a~single fluid pressure...... measurement located close to the accumulator. Gas leakage is shown to create increased variations in this pressure signal. The Root Mean Square (RMS) of the detail coefficient Level 9 from the MSD is found as the most sensitive and robust fault indicator of gas leakage. The method is verified...... on an experimental setup allowing for the replication of the conditions for accumulators in wind turbines. Robustness is tested in a multi-fault environment where gas and external fluid leakage occurs simultaneously. In total, 24 experiments are performed, which show that the method is sensitive to gas leakage...

  7. Management of chyle leakage after thyroidectomy, cervical lymph node dissection, in patients with thyroid cancer.

    Science.gov (United States)

    Park, Inhye; Her, Nayoon; Choe, Jun-Ho; Kim, Jee Soo; Kim, Jung-Han

    2018-01-01

    The purpose of this study was to evaluate the incidence and pattern of chyle leakage after thyroidectomy and/or cervical lymph node dissection and to establish management protocols for chyle leakage. Patients who underwent surgical management for thyroid cancer were analyzed retrospectively. For this study, 131 patients with chyle leakage were identified; the overall incidence was 0.9%. Of them, 43.7% of patients underwent central neck dissection without lateral neck dissection, and chyle leakage was easily controlled with conservative management. Patients whose chyle drainage was reduced by >50% after dietary modification had a significantly shorter hospital stay (P leakage after central compartment dissection even without lateral neck dissection was not rare, but was easily controlled with conservative management. Surgical management should be considered if the drainage amount does not decrease by >50% of the original amount of the day of detection after 2 days of NPO. © 2017 Wiley Periodicals, Inc.

  8. Study on detecting leachate leakage of municipal solid waste landfill site.

    Science.gov (United States)

    Liu, Jiangang; Cao, Xianxian; Ai, Yingbo; Zhou, Dongdong; Han, Qiting

    2015-06-01

    The article studies the detection of the leakage passage of leachate in a waste landfill dam. The leachate of waste landfill has its own features, like high conductivity, high chroma and an increasing temperature, also, the horizontal flow velocity of groundwater on the leakage site increases. This article proposes a comprehensive tracing method to identify the leakage site of an impermeable membrane by using these features. This method has been applied to determine two leakage sites of the Yahu municipal solid waste landfill site in Pingshan District, Shenzhen, China, which shows that there are two leachate leakage passages in the waste landfill dam A between NZK-2 and NZK-3, and between NZK-6 and NZK-7. © The Author(s) 2015.

  9. WWER steam generator tube structural and leakage integrity

    International Nuclear Information System (INIS)

    Splichal, K.; Krhounek, Vl.; Otruba, J.; Ruscak, M.

    1998-01-01

    The integrity of heat exchange tubes may influence the lifetime of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirements are to assure very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evaluation and heat exchange tubes plugging. The stress corrosion cracking and pitting are the main corrosion damages of WWER heat exchange tubes and are initiated from the outer surface. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through wall cracks, oriented preferentially in the axial direction. The paper presents the leakage and plugging limits for WWER steam generators, which have been determined from leak tests and burst tests. The tubes with axial part-through and through-wall defects have been used. The permissible value of primary to secondary leak rate was evaluated with respect to permissible axial through-wall defect size of WWER 440 and 1000 steam generator tubes. Blocking of the tube cracks by corrosion product particles and other compounds reduces the primary to secondary leak rate. The plugging limits involve the following factors: permissible tube wall thickness which determine further operation of the tubes with defects and assures their integrity under operating conditions and permissible size of a through-wall crack which is sufficiently stable under normal and accident conditions in relation to the critical crack length. For the evaluation of burst test of heat exchange tubes with longitudinal through-wall defects the instability criterion has been used and the dependence of the normalised burst pressure on the normalised length of an axial through-wall defect has been determined. The validity of the criterion of instability for WWER tubes with through

  10. Pad use and patient reported bother from urinary leakage after radical prostatectomy.

    Science.gov (United States)

    Wallerstedt, Anna; Carlsson, Stefan; Nilsson, Andreas E; Johansson, Eva; Nyberg, Tommy; Steineck, Gunnar; Wiklund, N Peter

    2012-01-01

    To better understand clinically significant definitions of urinary incontinence we investigated the relationship between urinary leakage and patient reported bother from urinary leakage. A consecutive series of 1,411 men who underwent radical prostatectomy at Karolinska University Hospital, Stockholm, Sweden, from 2002 to 2006 were invited to complete a study specific questionnaire with questions on pad status, urinary leakage and bother from urinary leakage. Questionnaires were received from 1,179 men with a followup of greater than 1 year (median 2.2). Results showed that even a small amount of urinary leakage resulted in a high risk of urinary bother. Of 775 survivors 46 (6%) reporting 0 pads indicated moderate or much bother compared to 38 of 123 (31%) who reported using a security pad. When comparing the 2 groups, the risk of bother from urinary leakage was more than 5 times higher in the safety pad vs the 0 pad group (RR 5.2, 95% CI 3.5-7.7). As the number of pads increased, we noted a higher bother risk. Cross-tabulation of pad use and urinary leakage revealed wide variation in pad requirements despite the same answer to urinary leakage questions. If the definition of continence is based on pad use, for example safety pads, a certain number of men who report moderate or much bother from urinary leakage will be defined as continent. Our results also show that for each stated rate of urinary leakage men prove to have a major variation in the pad requirement. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Specifics of Building Envelope Air Leakage Problems and Airtightness Measurements

    Directory of Open Access Journals (Sweden)

    Borodinecs Anatolijs

    2016-01-01

    Full Text Available In addition to transmission heat loses the infiltration of outdoor air can cause significant heat losses. The external building envelope should be airtight in order to prevent uncontrolled cold air infiltration. The article analysis modern building materials and structures influence on airtightness. The practical measurements of renovated buildings’ airtightness are presented and compared to non-renovated buildings. In addition paper presents data on airtightness measurements of whole multi apartment building and single apartment in analyzed building taking inco accout properties of building materials. The airtightness of single apartment was evaluated with support pressure in neighbor apartments. The results show that the airtightness measurements of multi apartment building can be evaluated by measuring single apartment on last floor with support pressure in neighbor apartments. The practical measurement of renovated buildings had shown the air leakage rate q50 of typical Latvian construction after renovation is between 2.5 and 2.9 m3/(m2·h. Since the building envelope has to minimize the heat loses (transmission and infiltration and ventilation system either mechanical or natural has to provide necessary air exchange, the building envelope airtightness shouldn’t be dependent on type of ventilation systems.

  12. Structural and leakage integrity assessment of WWER steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Splichal, K.; Otruba, J. [Nuclear Research Inst., Rez (Switzerland)

    1997-12-31

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction. 10 refs.

  13. Rubber contact mechanics: adhesion, friction and leakage of seals.

    Science.gov (United States)

    Tiwari, A; Dorogin, L; Tahir, M; Stöckelhuber, K W; Heinrich, G; Espallargas, N; Persson, B N J

    2017-12-13

    We study the adhesion, friction and leak rate of seals for four different elastomers: Acrylonitrile Butadiene Rubber (NBR), Ethylene Propylene Diene (EPDM), Polyepichlorohydrin (GECO) and Polydimethylsiloxane (PDMS). Adhesion between smooth clean glass balls and all the elastomers is studied both in the dry state and in water. In water, adhesion is observed for the NBR and PDMS elastomers, but not for the EPDM and GECO elastomers, which we attribute to the differences in surface energy and dewetting. The leakage of water is studied with rubber square-ring seals squeezed against sandblasted glass surfaces. Here we observe a strongly non-linear dependence of the leak rate on the water pressure ΔP for the elastomers exhibiting adhesion in water, while the leak rate depends nearly linearly on ΔP for the other elastomers. We attribute the non-linearity to some adhesion-related phenomena, such as dewetting or the (time-dependent) formation of gas bubbles, which blocks fluid flow channels. Finally, rubber friction is studied at low sliding speeds using smooth glass and sandblasted glass as substrates, both in the dry state and in water. The measured friction coefficients are compared to theory, and the origin of the frictional shear stress acting in the area of real contact is discussed. The NBR rubber, which exhibits the strongest adhesion both in the dry state and in water, also shows the highest friction both in the dry state and in water.

  14. Electrical leakage phenomenon in heteroepitaxial cubic silicon carbide on silicon

    Science.gov (United States)

    Pradeepkumar, Aiswarya; Zielinski, Marcin; Bosi, Matteo; Verzellesi, Giovanni; Gaskill, D. Kurt; Iacopi, Francesca

    2018-06-01

    Heteroepitaxial 3C-SiC films on silicon substrates are of technological interest as enablers to integrate the excellent electrical, electronic, mechanical, thermal, and epitaxial properties of bulk silicon carbide into well-established silicon technologies. One critical bottleneck of this integration is the establishment of a stable and reliable electronic junction at the heteroepitaxial interface of the n-type SiC with the silicon substrate. We have thus investigated in detail the electrical and transport properties of heteroepitaxial cubic silicon carbide films grown via different methods on low-doped and high-resistivity silicon substrates by using van der Pauw Hall and transfer length measurements as test vehicles. We have found that Si and C intermixing upon or after growth, particularly by the diffusion of carbon into the silicon matrix, creates extensive interstitial carbon traps and hampers the formation of a stable rectifying or insulating junction at the SiC/Si interface. Although a reliable p-n junction may not be realistic in the SiC/Si system, we can achieve, from a point of view of the electrical isolation of in-plane SiC structures, leakage suppression through the substrate by using a high-resistivity silicon substrate coupled with deep recess etching in between the SiC structures.

  15. Potential acidification impacts on zooplankton in CCS leakage scenarios.

    Science.gov (United States)

    Halsband, Claudia; Kurihara, Haruko

    2013-08-30

    Carbon capture and storage (CCS) technologies involve localized acidification of significant volumes of seawater, inhabited mainly by planktonic species. Knowledge on potential impacts of these techniques on the survival and physiology of zooplankton, and subsequent consequences for ecosystem health in targeted areas, is scarce. The recent literature has a focus on anthropogenic greenhouse gas emissions into the atmosphere, leading to enhanced absorption of CO2 by the oceans and a lowered seawater pH, termed ocean acidification. These studies explore the effects of changes in seawater chemistry, as predicted by climate models for the end of this century, on marine biota. Early studies have used unrealistically severe CO2/pH values in this context, but are relevant for CCS leakage scenarios. Little studied meso- and bathypelagic species of the deep sea may be especially vulnerable, as well as vertically migrating zooplankton, which require significant residence times at great depths as part of their life cycle. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Investigation of Underground Hydrocarbon Leakage using Ground Penetrating Radar

    Science.gov (United States)

    Srigutomo, Wahyu; Trimadona; Agustine, Eleonora

    2016-08-01

    Ground Penetrating Radar (GPR) survey was carried out in several petroleum plants to investigate hydrocarbon contamination beneath the surface. The hydrocarbon spills are generally recognized as Light Non-Aqueous Phase Liquids (LNAPL) if the plume of leakage is distributed in the capillary fringe above the water table and as Dense Non-Aqueous Phase Liquids (DNAPL) if it is below the water table. GPR antennas of 200 MHz and 400 MHz were deployed to obtain clear radargrams until 4 m deep. In general, the interpreted radargram sections indicate the presence of surface concrete layer, the compacted silty soill followed by sand layer and the original clayey soil as well as the water table. The presence of hydrocarbon plumes are identified as shadow zones (radar velocity and intensity contrasts) in the radargram that blur the layering pattern with different intensity of reflected signal. Based on our results, the characteristic of the shadow zones in the radargram is controlled by several factors: types of hydrocarbon (fresh or bio-degraded), water moisture in the soil, and clay content which contribute variation in electrical conductivity and dielectric constants of the soil.

  17. Smart integrated containment leakage rate test system using wireless communication

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hwan; Lee, Sang Yong; Kim, Jung Sun; Kim, Gun Soo; Kim, Jong Myeong; Ahn, Jong Han [Research and Development Center, Ulsan (Korea, Republic of)

    2012-10-15

    Integrated Leakage Rate Test (ILRT) is the important test the confidentiality and integrity of the containment building, which is the last barrier when Design basis accidents (DBA) of Nuclear Power plant occur. Since the result of this test is the basis to guarantee the safety of nuclear power plants, the test process, test procedure, and the test equipment are required to have high reliability. The test devices previously used have been products of VOLUMERTRICS and GRAFTEL of USA. These devices have been inconvenient to calibrate and use. Thus improved devices needed to be developed to remove the inconveniences, to verify the safety of Korean nuclear power plants with Korea's own technology, and to secure core technology. A new leak test system was developed by domestic technology for that purpose and needed to be verified. In this paper, technical details of the newly developed easy to use and highly reliable measuring test device, which is in operation at the nuclear power plant sites, will be introduced. State of art technology was applied to the device to address the shortcomings of previous US made devices and the difficulties to use on site.

  18. Feasibility study of tank leakage mitigation using subsurface barriers

    International Nuclear Information System (INIS)

    Treat, R.L.; Peters, B.B.; Cameron, R.J.; McCormak, W.D.; Trenkler, T.; Walters, M.F.; Rouse, J.K.; McLaughlin, T.J.; Cruse, J.M.

    1994-01-01

    The US Department of Energy (DOE) has established the Tank Waste Remediation System (TWRS) to satisfy manage and dispose of the waste currently stored in the underground storage tanks. The retrieval element of TWRS includes a work scope to develop subsurface impermeable barriers beneath SSTs. The barriers could serve as a means to contain leakage that may result from waste retrieval operations and could also support site closure activities by facilitating cleanup. Three types of subsurface barrier systems have emerged for further consideration: (1) chemical grout, (2) freeze walls, and (3) desiccant, represented in this feasibility study as a circulating air barrier. This report contains analyses of the costs and relative risks associated with combinations retrieval technologies and barrier technologies that from 14 alternatives. Eight of the alternatives include the use of subsurface barriers; the remaining six nonbarrier alternative are included in order to compare the costs, relative risks and other values of retrieval with subsurface barriers. Each alternative includes various combinations of technologies that can impact the risks associated with future contamination of the groundwater beneath the Hanford Site to varying degrees. Other potential risks associated with these alternatives, such as those related to accidents and airborne contamination resulting from retrieval and barrier emplacement operations, are not quantitatively evaluated in this report

  19. Assessment of Petroleum Leakage in Groundwater of the Abadan Refinery

    Directory of Open Access Journals (Sweden)

    Seyed Reza Shadizadeh

    2010-06-01

    Full Text Available Knowledge of petroleum leakage at oil refineries is vital for environmental study of water and soil pollution. Abadan Refinery is located between the Arvandrud and Bahmanshir rivers in the highly populated area of Abadan city. These rivers supply domestic, industrial, and agricultural water toAbadancity. During the war betweenIranandIraq, enormous volumes of oil and petroleum products leaked from storage tanks and pipelines at Abadan Refinery into the surrounding environment. The resulting pollution is a serious threat and a growing environmental concern for the region. In this work, twenty boreholes were dug to investigate petroleum leaks into the surrounding area both during and after the war. The thickness of petroleum floating on underground waters at the refinery was measured by sampling underground water over a period of one year along with measuring the piezometric heads of groundwater monitoring wells. Also, groundwater movement pattern at Abadan Refinery was determined by measuring the water table in each well over the same period. The results of sampling indicate that oil leaks were observed in just two wells; namely, wells No.3 and No.11. The results also show that the greatest portion of the oil spill in underground layers at Abadan Refinery was absorbed into clay soil.

  20. Potential acidification impacts on zooplankton in CCS leakage scenarios

    International Nuclear Information System (INIS)

    Halsband, Claudia; Kurihara, Haruko

    2013-01-01

    Highlights: • Effects of CCS techniques and ocean acidification on zooplankton are under-studied. • Vulnerable zooplankton are meso-, bathypelagic and vertically migrating species. • Impacts include impaired calcification, reproduction, development and survival. • Need for modelling studies combining physico-chemical with ecological impacts. -- Abstract: Carbon capture and storage (CCS) technologies involve localized acidification of significant volumes of seawater, inhabited mainly by planktonic species. Knowledge on potential impacts of these techniques on the survival and physiology of zooplankton, and subsequent consequences for ecosystem health in targeted areas, is scarce. The recent literature has a focus on anthropogenic greenhouse gas emissions into the atmosphere, leading to enhanced absorption of CO 2 by the oceans and a lowered seawater pH, termed ocean acidification. These studies explore the effects of changes in seawater chemistry, as predicted by climate models for the end of this century, on marine biota. Early studies have used unrealistically severe CO 2 /pH values in this context, but are relevant for CCS leakage scenarios. Little studied meso- and bathypelagic species of the deep sea may be especially vulnerable, as well as vertically migrating zooplankton, which require significant residence times at great depths as part of their life cycle

  1. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.

    1997-01-01

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction

  2. The Dangers of Rooting: Data Leakage Detection in Android Applications

    Directory of Open Access Journals (Sweden)

    Luca Casati

    2018-01-01

    Full Text Available Mobile devices are widely spread all over the world, and Android is the most popular operative system in use. According to Kaspersky Lab’s threat statistic (June 2017, many users are tempted to root their mobile devices to get an unrestricted access to the file system, to install different versions of the operating system, to improve performance, and so on. The result is that unintended data leakage flaws may exist. In this paper, we (i analyze the security issues of several applications considered relevant in terms of handling user sensitive information, for example, financial, social, and communication applications, showing that 51.6% of the tested applications suffer at least of an issue and (ii show how an attacker might retrieve a user access token stored inside the device thus exposing users to a possible identity violation. Notice that such a token, and a number of other sensitive information, can be stolen by malicious users through a man-in-the-middle (MITM attack.

  3. Method of detecting leakage from sealing attached to pressure tube

    International Nuclear Information System (INIS)

    Tomomatsu, Ken-ichi; Hayashi, Ken-ichi.

    1990-01-01

    The present invention provides a detection method for measuring the amount of water leaked from sealings attached to the lower end of a pressure tube. That is, the lower end of the pressure tube is sealed only by a metal sealing. A capturing vessel is placed under the pressure tube for capturing the leaked water dropping from the lower end of the pressure tube and the weight of the leaked water is measured on every capturing vessels to determine the amount of the leaked water. The leakage detection method based on the weight measurement has higher accuracy compared with a conventional volume measuring method using a water level gauge as described below. For example, if the volume of the captured water is 10cc, an error of about 0.1cc is caused by the volume measuring method using the water level gauge, whereas if 10g (10cc) weight of water is measured by using an accurate balance, error is only about 10 -4 g (10 -4 cc). Accordingly, the method of the present invention can measure at an accuracy about 1000 times as high as the conventional method. (I.S.)

  4. Managing the Cost of Plant Piping System Leakage

    International Nuclear Information System (INIS)

    Jenco, John M.; Keck, Donna R.; Johnson, Gary L.

    2002-01-01

    Recent studies have shown that the average annual cost impact of external piping system leakage on commercial nuclear plant operations and maintenance can easily range into the millions of dollars for each reactor unit. Evidence suggests that this significant O and M cost reduction opportunity has largely been overlooked, due to the number of diverse line items and budget areas affected. Results released last year from an EPRI pilot study of more than a dozen reactor units at seven plant sites operated by multiple utilities found that the average annual cost impact was indeed around $1.6 million per year per unit. Subsequent field experience has also demonstrated that an effective fluid leak management program can substantially reduce these costs within the first three years of implementation. This paper presents the general cost impact research results from various studies, outlines key elements of an effective plant fluid leak management program, discusses important implementation issues, and presents results from case studies covering different utility approaches to developing and implementing an effective fluid leak management program. Actual cost data will be included where appropriate. (authors)

  5. Anastomotic leakage after colorectal surgery: diagnostic accuracy of CT

    Energy Technology Data Exchange (ETDEWEB)

    Kauv, Paul; Benadjaoud, Samir; Boulay-Coletta, Isabelle; Zins, Marc [Fondation Hopital Saint-Joseph, Department of Radiology, Paris (France); Curis, Emmanuel [Universite Paris Descartes, Laboratoire de biomathematiques, Faculte de pharmacie, Paris (France); Loriau, Jerome [Fondation Hopital Saint-Joseph, Department of Digestive Surgery, Paris (France)

    2015-12-15

    To evaluate the diagnostic accuracy of CT in postoperative colorectal anastomotic leakage (AL). Two independent blinded radiologists reviewed 153 CTs performed for suspected AL within 60 days after surgery in 131 consecutive patients, with (n = 58) or without (n = 95) retrograde contrast enema (RCE). Results were compared to original interpretations. The reference standard was reoperation or consensus (a radiologist and a surgeon) regarding clinical, laboratory, radiological, and follow-up data after medical treatment. AL was confirmed in 34/131 patients. For the two reviewers and original interpretation, sensitivity of CT was 82 %, 87 %, and 71 %, respectively; specificity was 84 %, 84 %, and 92 %. RCE significantly increased the positive predictive value (from 40 % to 88 %, P = 0.0009; 41 % to 92 %, P = 0.0016; and 40 % to 100 %, P = 0.0006). Contrast extravasation was the most sensitive (reviewers, 83 % and 83 %) and specific (97 % and 97 %) sign and was significantly associated with AL by univariate analysis (P < 0.0001 and P < 0.0001). By multivariate analysis with recursive partitioning, CT with RCE was accurate to confirm or rule out AL with contrast extravasation. CT with RCE is accurate for diagnosing postoperative colorectal AL. Contrast extravasation is the most reliable sign. RCE should be performed during CT for suspected AL. (orig.)

  6. Structural and leakage integrity assessment of WWER steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Splichal, K; Otruba, J [Nuclear Research Inst., Rez (Switzerland)

    1998-12-31

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction. 10 refs.

  7. Data Leakage Prevention: E-Mail Protection via Gateway

    Science.gov (United States)

    Kaur, Kamaljeet; Gupta, Ishu; Singh, Ashutosh Kumar

    2018-01-01

    Protection of digital assets and intellectual property is becoming a challenge for most of the companies. Due to increasing availability of database services on internet, data may be insecure after passing through precarious networks. To protect intellectual property (IP) is a major concern for today's organizations, because a leakage that compromises IP means, sensitive information of a company is in the hands of biggest competitors. Electronic information processing and communication is replacing paper in many applications increasingly. Instead of paper, an email is being used for communication at workplace and from social media logins to bank accounts. Nowadays an email is becoming a mainstream business tool. An email can be misused to leave company’s sensitive data open to compromise. So, it may be of little surprise that attacks on emails are common. So, here we need an email protection system (EPS) that will protect information to leave organization via mail. In this paper, we developed an algorithm that will offer email protection via gateway during data transfer. This algorithm matches the patterns with the keywords stored in the database and then takes the actions accordingly to protect the data. This paper describes why email protection is important? How companies can protect their confidential information from being leaked by insiders.

  8. Study tube housing leakage of 111 conventional diagnostic X-ray machines using ion chamber survey meter

    International Nuclear Information System (INIS)

    Lalrinmawia, Jonathan; Tiwari, Ramesh Chandra; Pau, Kham Suan

    2018-01-01

    This study aims at measuring the leakage radiation from X-ray tube and compare to national and international safety standard. The leakage radiation is formed at the anode inside the X-ray tube and transmitted through the tube housing. The tube housing is proposed to protect both patients and workers from leakage radiation. To the best of the authors' knowledge, no tube housing leakage measurements have been done so far in the present study area

  9. CT evaluation of local leakage of bone cement after percutaneous kyphoplasty and vertebroplasty

    International Nuclear Information System (INIS)

    Lee, In Jae; Choi, A. Lam; Yie, Mi-Yeon; Yoon, Ji Young; Jeon, Eui Yong; Koh, Sung Hye; Yoon, Dae Young; Lim, Kyung Ja; Im, Hyoung June

    2010-01-01

    Background: Percutaneous injection of bone cement (acrylic cement) during percutaneous kyphoplasty and vertebroplasty can cause symptomatic or asymptomatic complications due to leakage, extravasation or vascular migration of cement. Purpose: To investigate and to compare the incidence and site of local leakage or complications of bone cement after percutaneous kyphoplasty and vertebroplasty using bone cement. Material and Methods: We retrospectively reviewed 473 cases of percutaneous kyphoplasty or vertebroplasty performed under fluoroscopic guidance. Of the 473 cases, follow-up CT scans that covered the treated bones were available for 83 cases (59 kyphoplasty and 24 vertebroplasty). Results: The rate of local leakage of bone cement was 87.5% (21/24) for percutaneous vertebroplasty and 49.2% (29/59) for kyphoplasty. The most common site of local leakage was perivertebral soft tissue (n=8, 38.1%) for vertebroplasty. The most common site of local leakage was a perivertebral vein (n=7, 24.1%) for kyphoplasty. Two cases of pulmonary cement embolism developed: one case after kyphoplasty and one case after vertebroplasty. Conclusion: Local leakage of bone cement was more common for percutaneous vertebroplasty compared with kyphoplasty (P<0.005). The most common sites of local leakage were perivertebral soft tissue and perivertebral vein.

  10. Enhanced ground bounce noise reduction in a low-leakage CMOS multiplier

    Science.gov (United States)

    Verma, Bipin Kumar; Akashe, Shyam; Sharma, Sanjay

    2015-09-01

    In this paper, various parameters are used to reduce leakage power, leakage current and noise margin of circuits to enhance their performance. A multiplier is proposed with low-leakage current and low ground bounce noise for the microprocessor, digital signal processors (DSP) and graphics engines. The ground bounce noise problem appears when a conventional power-gating circuit transits from sleep-to-active mode. This paper discusses a reduction in leakage current in the stacking power-gating technique by three modes - sleep, active and sleep-to-active. The simulation results are performed on a 4 × 4 carry-save multiplier for leakage current, active power, leakage power and ground bounce noise, and comparison made for different nanoscales. Ground bounce noise is limited to 90%. The leakage current of the circuit is decimated up to 80% and the active power is reduced to 31%. We performed simulations using cadence virtuoso 180 and 45 nm at room temperature at various supply voltages.

  11. Leakage and sweet spots in triple-quantum-dot spin qubits: A molecular-orbital study

    Science.gov (United States)

    Zhang, Chengxian; Yang, Xu-Chen; Wang, Xin

    2018-04-01

    A triple-quantum-dot system can be operated as either an exchange-only qubit or a resonant-exchange qubit. While it is generally believed that the decisive advantage of the resonant-exchange qubit is the suppression of charge noise because it is operated at a sweet spot, we show that the leakage is also an important factor. Through molecular-orbital-theoretic calculations, we show that when the system is operated in the exchange-only scheme, the leakage to states with double electron occupancy in quantum dots is severe when rotations around the axis 120∘ from z ̂ is performed. While this leakage can be reduced by either shrinking the dots or separating them further, the exchange interactions are also suppressed at the same time, making the gate operations unfavorably slow. When the system is operated as a resonant-exchange qubit, the leakage is three to five orders of magnitude smaller. We have also calculated the optimal detuning point which minimizes the leakage for the resonant-exchange qubit, and have found that although it does not coincide with the double sweet spot for the charge noise, they are rather close. Our results suggest that the resonant-exchange qubit has another advantage, that leakage can be greatly suppressed compared to the exchange-only qubit, and operating at the double sweet spot point should be optimal both for reducing charge noise and suppressing leakage.

  12. Leakage limits for inflatable seals of sodium cooled fast breeder reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, N.K., E-mail: nksinha@igcar.gov.in; Raj, Baldev

    2014-01-15

    Highlights: • All possible types/modes of gas escape covered. • Limits include simultaneous contributions from bypass and permeation leakage modes. • Leakage of radioactive cover gas with fission products assumed. • Possibility of sodium frost deposition in sealed gap considered. • Cover gas activity decay during fuel handling and relative importance of types/modes of leakage considered for realistic results and simpler seal design. -- Abstract: Estimation and stipulation of allowable leakage for inflatable seals of 500 MWe Prototype Fast Breeder Reactor is depicted. Leakage limits are specified using a conservative approach, which assumes escape of radioactive cover gas with fission products across the seals in bypass and permeation modes and possibility of sodium frost deposition in sealed gaps because of permeation leakage of inflation gas. Procedures to arrive at the allowable leakages of argon cover gas (normal-operation/fuel-handling: 10{sup −3}/10{sup −2} scc/s/m length of seal) and argon inflation gas (10{sup −3} scc/s/m length of seal) is described.

  13. A new on-line leakage current monitoring system of ZnO surge arresters

    International Nuclear Information System (INIS)

    Lee, Bok-Hee; Kang, Sung-Man

    2005-01-01

    This paper presents a new on-line leakage current monitoring system of zinc oxide (ZnO) surge arresters. To effectively diagnose the deterioration of ZnO surge arresters, a new algorithm and on-line leakage current detection device, which uses the time-delay addition method, for discriminating the resistive and capacitive currents was developed to use in the aging test and durability evaluation for ZnO arrester blocks. A computer-based measurement system of the resistive leakage current, the on-line monitoring device can detect accurately the leakage currents flowing through ZnO surge arresters for power frequency ac applied voltages. The proposed on-line leakage current monitoring device of ZnO surge arresters is more highly sensitive and gives more linear response than the existing devices using the detection method of the third harmonic leakage currents. Therefore, the proposed leakage current monitoring device can be useful for predicting the defects and performance deterioration of ZnO surge arresters in power system applications

  14. RETRAN code analysis of Tsuruga-2 plant chemical volume control system (CVCS) reactor coolant leakage incident

    International Nuclear Information System (INIS)

    Kawai, Hiroshi

    2002-01-01

    In the Chemical Volume Control System (CVCS) reactor primary coolant leakage incident, which occurred in Tsuruga-2 (4-loop PWR, 3,423 MWt, 1,160 MWe) on July 12, 1999, it took about 14 hours before the leakage isolation. The delayed leakage isolation and a large amount of leakage have become a social concern. Effective procedure modification was studied. Three betterments were proposed based on a qualitative analysis to reduce the pressure and temperature of the primary loop as fast as possible by the current plant facilities while maintaining enough subcooling of the primary loop. I analyzed the incident with RETRAN code in order to quantitatively evaluate the leakage reduction when these betterments are adopted. This paper is very new because it created a typical analysis method for PWR plant behavior during plant shutdown procedure which conventional RETRAN transient analyses rarely dealt with. Also the event time is very long. To carry out this analysis successfully, I devised new models such as an Residual Heat Removal System (RHR) model etc. and simplified parts of the conventional model. Based on the analysis results, I confirmed that leakage can be reduced by about 30% by adopting these betterments. Then the Japan Atomic Power Company (JAPC) modified the operational procedure for reactor primary coolant leakage events adopting these betterments. (author)

  15. Impact of leakage delay on bifurcation in high-order fractional BAM neural networks.

    Science.gov (United States)

    Huang, Chengdai; Cao, Jinde

    2018-02-01

    The effects of leakage delay on the dynamics of neural networks with integer-order have lately been received considerable attention. It has been confirmed that fractional neural networks more appropriately uncover the dynamical properties of neural networks, but the results of fractional neural networks with leakage delay are relatively few. This paper primarily concentrates on the issue of bifurcation for high-order fractional bidirectional associative memory(BAM) neural networks involving leakage delay. The first attempt is made to tackle the stability and bifurcation of high-order fractional BAM neural networks with time delay in leakage terms in this paper. The conditions for the appearance of bifurcation for the proposed systems with leakage delay are firstly established by adopting time delay as a bifurcation parameter. Then, the bifurcation criteria of such system without leakage delay are successfully acquired. Comparative analysis wondrously detects that the stability performance of the proposed high-order fractional neural networks is critically weakened by leakage delay, they cannot be overlooked. Numerical examples are ultimately exhibited to attest the efficiency of the theoretical results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Postprocedural CT for perivertebral cement leakage in percutaneous vertebroplasty is not necessary - results from VERTOS II

    International Nuclear Information System (INIS)

    Venmans, Alexander; Klazen, Caroline A.; Rooij, Willem Jan van; Lohle, Paul N.; Vries, Jolanda de; Mali, Willem P.

    2011-01-01

    During percutaneous vertebroplasty (PV), perivertebral cement leakage frequently occurs. There is some concern that cement deposits may migrate towards the lungs via the veins during follow-up. We used baseline and follow-up computed tomography (CT) to assess the incidence and extend of late cement migration in a large consecutive patient cohort. VERTOS II is a prospective multicenter randomized controlled trial comparing PV with conservative therapy for osteoporotic vertebral compression fractures (OVCFs). Patients assigned to PV had baseline postprocedural CT scans of the treated vertebral bodies. After a mean follow-up of 22 months, 54 of 78 patients (69%) had follow-up CT. CT scans were analyzed and compared for perivertebral venous, discal, and soft tissue leakage. Perivertebral cement leakage occurred in 64 of 80 treated vertebrae (80%; 95% CI, 70% to 87%). All patients remained asymptomatic. Perivertebral venous leakage was present in 56 vertebrae (88%), mostly in the anterior external venous plexus (46 of 56, 82%). Discal leakage occurred in 22 of 64 vertebrae (34%) and soft tissue leakage in two of 64 (4%). Mean injected cement volume in vertebrae with leakage was higher (4.5 versus 3.7 cm 3 , p = 0.04). Follow-up CT scan showed unchanged perivertebral cement leakages without late cement migration. Perivertebral cement leaks during PV for OVCFs occurred frequently in the VERTOS II trial. Cement leakage occurred more frequently with higher injected volumes. However, all patients remained asymptomatic, and late cement migration during follow-up did not occur. Standard postprocedural CT of the treated vertebral body in PV is not necessary. (orig.)

  17. Postprocedural CT for perivertebral cement leakage in percutaneous vertebroplasty is not necessary - results from VERTOS II

    Energy Technology Data Exchange (ETDEWEB)

    Venmans, Alexander; Klazen, Caroline A.; Rooij, Willem Jan van; Lohle, Paul N. [St. Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Vries, Jolanda de [St. Elisabeth Ziekenhuis Tilburg, Department of Medical Psychology, Tilburg (Netherlands); Mali, Willem P. [University Medical Centre Utrecht, Department of Radiology, Utrecht (Netherlands)

    2011-01-15

    During percutaneous vertebroplasty (PV), perivertebral cement leakage frequently occurs. There is some concern that cement deposits may migrate towards the lungs via the veins during follow-up. We used baseline and follow-up computed tomography (CT) to assess the incidence and extend of late cement migration in a large consecutive patient cohort. VERTOS II is a prospective multicenter randomized controlled trial comparing PV with conservative therapy for osteoporotic vertebral compression fractures (OVCFs). Patients assigned to PV had baseline postprocedural CT scans of the treated vertebral bodies. After a mean follow-up of 22 months, 54 of 78 patients (69%) had follow-up CT. CT scans were analyzed and compared for perivertebral venous, discal, and soft tissue leakage. Perivertebral cement leakage occurred in 64 of 80 treated vertebrae (80%; 95% CI, 70% to 87%). All patients remained asymptomatic. Perivertebral venous leakage was present in 56 vertebrae (88%), mostly in the anterior external venous plexus (46 of 56, 82%). Discal leakage occurred in 22 of 64 vertebrae (34%) and soft tissue leakage in two of 64 (4%). Mean injected cement volume in vertebrae with leakage was higher (4.5 versus 3.7 cm{sup 3}, p = 0.04). Follow-up CT scan showed unchanged perivertebral cement leakages without late cement migration. Perivertebral cement leaks during PV for OVCFs occurred frequently in the VERTOS II trial. Cement leakage occurred more frequently with higher injected volumes. However, all patients remained asymptomatic, and late cement migration during follow-up did not occur. Standard postprocedural CT of the treated vertebral body in PV is not necessary. (orig.)

  18. A retrospective analysis of endoscopic treatment outcomes in patients with postoperative bile leakage.

    Science.gov (United States)

    Sayar, Suleyman; Olmez, Sehmus; Avcioglu, Ufuk; Tenlik, Ilyas; Saritas, Bunyamin; Ozdil, Kamil; Altiparmak, Emin; Ozaslan, Ersan

    2016-01-01

    Bile leakage, while rare, can be a complication seen after cholecystectomy. It may also occur after hepatic or biliary surgical procedures. Etiology may be underlying pathology or surgical complication. Endoscopic retrograde cholangiopancreatography (ERCP) can play major role in diagnosis and treatment of bile leakage. Present study was a retrospective analysis of outcomes of ERCP procedure in patients with bile leakage. Patients who underwent ERCP for bile leakage after surgery between 2008 and 2012 were included in the study. Etiology, clinical and radiological characteristics, and endoscopic treatment outcomes were recorded and analyzed. Total of 31 patients (10 male, 21 female) were included in the study. ERCP was performed for bile leakage after cholecystectomy in 20 patients, after hydatid cyst operation in 10 patients, and after hepatic resection in 1 patient. Clinical signs and symptoms of bile leakage included abdominal pain, bile drainage from percutaneous drain, peritonitis, jaundice, and bilioma. Twelve (60%) patients were treated with endoscopic sphincterotomy (ES) and nasobiliary drainage (NBD) catheter, 7 patients (35%) were treated with ES and biliary stent (BS), and 1 patient (5%) was treated with ES alone. Treatment efficiency was 100% in bile leakage cases after cholecystectomy. Ten (32%) cases of hydatid cyst surgery had subsequent cystobiliary fistula. Of these patients, 7 were treated with ES and NBD, 2 were treated with ES and BS, and 1 patient (8%) with ES alone. Treatment was successful in 90% of these cases. ERCP is an effective method to diagnose and treat bile leakage. Endoscopic treatment of postoperative bile leakage should be individualized based on etiological and other factors, such as accompanying fistula.

  19. Numerical studies of CO2 and brine leakage into a shallow aquifer through an open wellbore

    Science.gov (United States)

    Wang, Jingrui; Hu, Litang; Pan, Lehua; Zhang, Keni

    2018-03-01

    Industrial-scale geological storage of CO2 in saline aquifers may cause CO2 and brine leakage from abandoned wells into shallow fresh aquifers. This leakage problem involves the flow dynamics in both the wellbore and the storage reservoir. T2Well/ECO2N, a coupled wellbore-reservoir flow simulator, was used to analyze CO2 and brine leakage under different conditions with a hypothetical simulation model in water-CO2-brine systems. Parametric studies on CO2 and brine leakage, including the salinity, excess pore pressure (EPP) and initially dissolved CO2 mass fraction, are conducted to understand the mechanism of CO2 migration. The results show that brine leakage rates increase proportionally with EPP and inversely with the salinity when EPP varies from 0.5 to 1.5 MPa; however, there is no CO2 leakage into the shallow freshwater aquifer if EPP is less than 0.5 MPa. The dissolved CO2 mass fraction shows an important influence on the CO2 plume, as part of the dissolved CO2 becomes a free phase. Scenario simulation shows that the gas lifting effect will significantly increase the brine leakage rate into the shallow freshwater aquifer under the scenario of 3.89% dissolved CO2 mass fraction. The equivalent porous media (EPM) approach used to model the wellbore flow has been evaluated and results show that the EPM approach could either under- or over-estimate brine leakage rates under most scenarios. The discrepancies become more significant if a free CO2 phase evolves. Therefore, a model that can correctly describe the complex flow dynamics in the wellbore is necessary for investigating the leakage problems.

  20. Millennial-scale Agulhas Current variability and its implications for salt-leakage through the Indian–Atlantic Ocean Gateway

    NARCIS (Netherlands)

    Simon, M.H.; Arthur, K.L.; Hall, I.R.; Peeters, F.J.C.; Loveday, B.R.; Barker, S.; Zahn, R.

    2013-01-01

    The inter-ocean exchange of warm and salt-enriched waters around South Africa (Agulhas leakage), may have played an important role in the mechanism of deglaciations. Paleoceanographic reconstructions from the Agulhas leakage corridor show that leakage maxima occurred during glacial terminations.

  1. Dosimetry and evaluating the effect of treatment parameters on the leakage of multi leaf collimators in ONCOR linear accelerators

    Directory of Open Access Journals (Sweden)

    Keyvan Jabbari

    2016-01-01

    Conclusions: The amount of leakage was more for 18 MV compare to 6 MV The percentage of the leakage for both energies is less than the 5% value which is recommended by protocols. The fluctuation of the MLC leakage reduced by increasing the field size and depth.

  2. SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J; Bosco, G; Darenbourg, B; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of

  3. The Diagnosis of Internal Leakage of Control Valve Based on the Grey Correlation Analysis Method

    Directory of Open Access Journals (Sweden)

    Zheng DING

    2014-07-01

    Full Text Available The valve plays an important part in the industrial automation system. Whether it operates normally or not relates with the quality of the products directly while its faults are relatively common because of bad working conditions. And the internal leakage is one of the common faults. Consequently, this paper sets up the experimental platform to make the valve in different working condition and collect relevant data online. Then, diagnose the internal leakage of the valve by using the grey correlation analysis method. The results show that this method can not only diagnose the internal leakage of valve accurately, but also distinguish fault degree quantitatively.

  4. Acoustic emission monitoring of leakage through seal-plug in PHWR systems

    Energy Technology Data Exchange (ETDEWEB)

    Jha, S K; Badgujar, B P; Goswami, G L [Bhabha Atomic Research Centre, Bombay (India). Atomic Fuels Div.; Patel, R J; Bhattacharya, S; Agrawal, R G [Bhabha Atomic Research Centre, Mumbai (India). Refuelling Technology Division

    1994-12-31

    Acoustic Emission (AE) technique is being developed as an in-service inspection tool for monitoring the leakage through seal-plugs in Pressurised Heavy Water Reactors (PHWRs). Time as well as frequency domain analysis have been utilised during the experiment carried out at Bhabha Atomic Research Centre (BARC) using test set up simulating the pressure and temperature conditions. The work involved were to determine the temperature profile on end-fitting, effect of pressure and temperature on leakage etc. This paper discusses various relationships like signal-level vs. pressure, frequency spectrum of signal, signal-level vs. leakage based on the above experimental work. (author). 4 refs., 6 figs.

  5. Surface CO2 leakage during the first shallow subsurface CO2 release experiment

    OpenAIRE

    Lewicki, J.L.; Oldenburg, C.; Dobeck, L.; Spangler, L.

    2008-01-01

    A new field facility was used to study CO2 migration processes and test techniques to detect and quantify potential CO2 leakage from geologic storage sites. For 10 days starting 9 July 2007, and for seven days starting 5 August 2007, 0.1 and 0.3 t CO2 d-1, respectively, were released from a ~;100-m long, sub-water table (~;2.5-m depth) horizontal well. The spatio-temporal evolution of leakage was mapped through repeated grid measurements of soil CO2 flux (FCO2). The surface leakage onset...

  6. Influence of leakage flow on the behaviour of gas behind a blockage in LMFBR subassembly geometry

    International Nuclear Information System (INIS)

    Fukuzawa, Y.

    1980-07-01

    Observations were made of the behaviour of gas behind a uniform porous 21% corner blockage within a pin-bundle of LMFBR subassembly geometry. The main parameter of the experiment was the leakage flow rate through the blockage. The behaviour of gas is significantly influenced by the leakage flow rate. The measured size and residence time of a gas cavity formed behind the blockage are shown and the mechanisms of the gas cavity dispersion by the leakage flow discussed by using a simple model of the liquid flow distribution behind the blockage. (orig.) [de

  7. ERROR REDUCTION IN DUCT LEAKAGE TESTING THROUGH DATA CROSS-CHECKS

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS, J.W.

    1998-12-31

    One way to reduce uncertainty in scientific measurement is to devise a protocol in which more quantities are measured than are absolutely required, so that the result is over constrained. This report develops a method for so combining data from two different tests for air leakage in residential duct systems. An algorithm, which depends on the uncertainty estimates for the measured quantities, optimizes the use of the excess data. In many cases it can significantly reduce the error bar on at least one of the two measured duct leakage rates (supply or return), and it provides a rational method of reconciling any conflicting results from the two leakage tests.

  8. Cumulative Impacts of Energy and Climate Change Policies on Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Varma, A.; Milnes, R.; Miller, K.; Williams, E. [AEA Technology plc, London (United Kingdom); De Bruyn, S.; Brinke, L. [CE Delft, Delft (Netherlands)

    2012-02-15

    Carbon leakage occurs when climate change policy aimed at reducing carbon dioxide emissions in one country leads to an increase in carbon dioxide emissions in a country that is not bound by these policies. Given that climate change is a global issue, carbon leakage impacts upon the effectiveness of climate change policies. This independent study examines the cumulative impact of climate change policies on carbon leakage. The report brings together findings and analysis from a wide range of primary literature in this area and where possible, conclusions relevant to the UK are drawn.

  9. Model-based Estimation of Gas Leakage for Fluid Power Accumulators in Wind Turbines

    DEFF Research Database (Denmark)

    Liniger, Jesper; Pedersen, Henrik Clemmensen; N. Soltani, Mohsen

    2017-01-01

    for accumulators, namely gas leakage. The method utilizes an Extended Kalman Filter for joint state and parameter estimation with special attention to limiting the use of sensors to those commonly used in wind turbines. The precision of the method is investigated on an experimental setup which allows for operation...... of the accumulator similar to the conditions in a turbine. The results show that gas leakage is indeed detectable during start-up of the turbine and robust behavior is achieved in a multi-fault environment where both gas and external fluid leakage occur simultaneously. The estimation precision is shown...... to be sensitive to initial conditions for the gas temperature and volume....

  10. Leakage monitoring and maintenance for main heat-exchanger of project 871

    International Nuclear Information System (INIS)

    Li Yanshui; Cao Zhibin

    1995-01-01

    Main heat-exchanger is one of the most important equipment. To prevent the occurrence of leakage accident, desalting and water treatment for secondary cooling water is conducted chemical except controlling the water quality of coolant. There is a small loop for leakage monitoring to find out the leakage immediately. In order to ensure the safety of operation, the treatment of eliminating water dirt and inspection for outside and inside must be done periodically, and the relevant means must be adopted if any abnormal phenomenon is found

  11. Pulse sequences for suppressing leakage in single-qubit gate operations

    Science.gov (United States)

    Ghosh, Joydip; Coppersmith, S. N.; Friesen, Mark

    2017-06-01

    Many realizations of solid-state qubits involve couplings to leakage states lying outside the computational subspace, posing a threat to high-fidelity quantum gate operations. Mitigating leakage errors is especially challenging when the coupling strength is unknown, e.g., when it is caused by noise. Here we show that simple pulse sequences can be used to strongly suppress leakage errors for a qubit embedded in a three-level system. As an example, we apply our scheme to the recently proposed charge quadrupole (CQ) qubit for quantum dots. These results provide a solution to a key challenge for fault-tolerant quantum computing with solid-state elements.

  12. Containment Leakage Rate Testing Program in NPP Krsko

    International Nuclear Information System (INIS)

    Dudas, M.; Heruc, Z.

    2002-01-01

    NPP Krsko adopted new regulations for testing of the reactor building containment as stipulated by 10CFR50 (Code of Federal Regulation) Appendix J, Option B instead of the previous requirement 10CFR50 Appendix J now renamed to 10CFR50 Appendix J, Option A. In the USA a thorough analyses of nuclear power plants reactor building containment testing was conducted. As part of these analyses the test results obtained from testing of various reactor-building containments in the last ten years were reviewed. It was concluded that it would be meaningful to, based on test results historical data, reconsider possibility of redefining testing intervals. The official proposal of such approach was reviewed and approved by the NRC and published in September of 1995 in the FR Vol.60 No.186. Based on directions from 10CFR50 Appendix J, Option B, the new criteria for definition of test intervals were created. Criteria were based upon past performance during testing (Performance-based Requirements) and safety impact. At NPP Krsko, the analyses of the Reactor Building Containment. Integrity Test results was performed . This included test results of the Containment Integrated Leak Rate Testing (CILRT or Type A tests), Containment Isolation Valves Local Leak Rater Tests (Type C tests) and Mechanical and Electrical Penetrations Local Leak Rate tests (Type B tests). In accordance with instructions from NEI 94-01 and based on analyses of test results, NPP Krsko created Containment Leakage Rate Testing Program with the purpose to establish the performance-based definition of test intervals, inspection scope, trending and reporting. Equally, the program gives instructions how to evaluate test results and how to deal with the containment penetration or isolation valve repair contingency. All changes caused with transition from Option A to Option B are marginal to public safety. (author)

  13. Magnetic shaft seals prevent hazardous leakage from wastewater agitators

    International Nuclear Information System (INIS)

    Traino, F.A.

    1985-01-01

    The US Department of Energy's laboratory in Miamisburg, OH, operated by Monsanto Research Corporation, processes approximately 45,000 gallons per week of low-level radioactive wastewater to meet Federal Environmental Protection Agency quality standards. Preventing the spread of radioactive contamination throughout the operating area demands effective sealing of all process piping, valves, pumps, and agitators. Rotating shafts of pumps and agitators installed a the start of operations in 1947 were sealed by stuffing glands with graphite impregnated asbestos packing. These pumps proved to be unsatisfactory. In the mid-1970's, new process pumps with mechanical seals and some with magnetic drives were installed. Later, in January 1979, new agitator shaft drives with double tandem, spring-loaded mechanical seals were installed, maintenance of these pumps was costly. The agitator drive shafts were redesigned to accommodate magnetic seals of the type successfully used in blowers and vacuum/pressure pumps in other plant locations. One inherent advantage of the magnetic seal is that it operates with a face loading as much as 50% less than a conventional spring-loaded mechanical seal. The lower loading by a predetermined uniform magnetic force contributes to long face life. Other advantages include compactness, ease of assembly with only a few parts, and insensitivity to vibration. The magnetic shaft seals installed on the agitator shafts in February 1983 are still in service without any leakage or need for maintenance. Based on current operating data and a projected five-year meantime between failures, the estimated cost benefit of the magnetic seals over spring-loaded mechanical seals over spring-loaded mechanical seals will be $640 vs $2400 respectively per seal, with 60% less downtime for maintenance

  14. Detection of mechanical damage using the magnetic flux leakage technique

    International Nuclear Information System (INIS)

    Clapham, L.; Babbar, V.; Byrne, J.

    2007-01-01

    Since magnetism is strongly stress dependent, Magnetic Flux Leakage (MFL) inspection tools have the potential to locate and characterize mechanical damage in pipelines. However, MFL application to mechanical damage detection faces hurdles which make signal interpretation problematic: 1) the MFL signal is a superposition of geometrical and stress effects; 2) the stress distribution around a mechanically damaged region is very complex, consisting of plastic deformation and residual (elastic) stresses; 3) the effect of stress on magnetic behaviour is not well understood. This paper summarizes recent results of experimental and modeling studies of MFL signals resulting from mechanical damage. In experimental studies, mechanical damage was simulated using a tool and die press to produce dents of varying depths in plate samples. MFL measurements were made before and after selective stress-relieving heat treatments. These annealing treatments enabled the stress and geometry components of the MFL signal to be separated. In general, geometry effects scale with dent depth and tend to dominate in deep dents, while stress contribution to the MFL signals is relatively constant and is more significant for shallow dents. The influence of other parameters such as flux density and topside/bottomside inspection was also quantified. In the finite element analysis work, stress was incorporated by modifying the magnetic permeability in the residual stress regions of the modeled dent. Both stress and geometry contributions to the MFL signal were examined separately. Despite using a number of simplifying assumptions, the modeled results matched the experimental results very closely, and were used to aid in interpretation of the MFL signals. (author)

  15. Ion leakage from mixed beds in condensate polishing plants

    International Nuclear Information System (INIS)

    Venderbosch, H.W.; Overman, L.J.; Snel, A.

    1977-01-01

    In view to the interest for theoretical and practical factors, which influence the ion slip of mixed bed filters, these facts were studied in detail. It proved to be necessary that the slip shall be subdivided into kinetic - and elution slip. The kinetic slip is depending e.g. on the electrolyte concentration of the influenct condensate, as well as on the period of contact, however it does not depend on the regeneration condition; the elution slip however depends clearly on the regeneration condition. Incomplete regeneration of the exchangers, a too low excess of regenerant, incomplete separation of cation - and anion exchanger, and the contact of an exchanger layer with the wrong regenerant in the separation zone, during the internal regeneration are raising the slip. With tests on mixed bed filters, which have been well regenerated, (less than 0.1% Na in the cation exchanger) and by using filters with normal regenerated exchangers, (approx. 10% Na in the cation exchanger) the quality of the effluent was compared with values, which were expected from calculations. In order to decrease the elution leakage, the contamination of the exchangers, especially at NH 4 OH - mixed bed filters, must be limited to a very low percentage. Several possibilities to obtain this, will be discussed in the lecture. Special attention will be paid to the internal regeneration procedure. KEMA has developed a method, the so-called partial regeneration method, in order to operate internal regenerated mixed bed filters, which have been designed for the HOH cycle, also in the ammonia form, without the occurence of an undue slip of sodium or chloride. Not only extended running periods and lower operating- and regeneration costs are of advantage, but also the reducing of salt- and ammonia containing sewage were achieved. (orig.) [de

  16. Cerebrospinal fluid leakage during transsphenoidal surgery: postoperative external lumbar drainage reduces the risk for meningitis

    NARCIS (Netherlands)

    van Aken, M. O.; Feelders, R. A.; de Marie, S.; van de Berge, J. H.; Dallenga, A. H. G.; Delwel, E. J.; Poublon, R. M. L.; Romijn, J. A.; van der Lely, A. J.; Lamberts, S. W. J.; de Herder, W. W.

    2004-01-01

    Postoperative meningitis is a well known complication of transsphenoidal surgery (TSS). The objective of this study was to evaluate whether postoperative external cerobrospinal fluid (CSF) drainage in case of intraoperative CSF-leakage, reduces the risk of postoperative meningitis. We

  17. Computing Optimal Mixed Strategies for Terrorist Plot Detection Games with the Consideration of Information Leakage

    Directory of Open Access Journals (Sweden)

    Li MingChu

    2017-01-01

    Full Text Available The terrorist’s coordinated attack is becoming an increasing threat to western countries. By monitoring potential terrorists, security agencies are able to detect and destroy terrorist plots at their planning stage. Therefore, an optimal monitoring strategy for the domestic security agency becomes necessary. However, previous study about monitoring strategy generation fails to consider the information leakage, due to hackers and insider threat. Such leakage events may lead to failure of watching potential terrorists and destroying the plot, and cause a huge risk to public security. This paper makes two major contributions. Firstly, we develop a new Stackelberg game model for the security agency to generate optimal monitoring strategy with the consideration of information leakage. Secondly, we provide a double-oracle framework DO-TPDIL for calculation effectively. The experimental result shows that our approach can obtain robust strategies against information leakage with high feasibility and efficiency.

  18. Inward contaminant leakage tests of the S-Tron Corporation emergency escape breathing device.

    Science.gov (United States)

    1992-04-01

    At the request of S-Tron Corporation, to support their contract with the U.S. Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur ...

  19. Intrathoracic Anastomotic Leakage after Gastroesophageal Cancer Resection Is Associated with Reduced Long-term Survival

    DEFF Research Database (Denmark)

    Kofoed, Steen Christian; Calatayud, Dan; Jensen, Lone Susanne

    2014-01-01

    BACKGROUND: Most likely because of low statistical power, no previous studies have shown any significant association between long-term survival and anastomotic leakage in patients who have undergone gastroesophageal cancer resection. MATERIAL AND METHODS: The present study included, prospectively...

  20. Increased risk of anastomotic leakage with diclofenac treatment after laparoscopic colorectal surgery

    DEFF Research Database (Denmark)

    Klein, Mads; Andersen, Lars Peter Holst; Harvald, Thomas

    2009-01-01

    BACKGROUND: Over a period our department experienced an unexpected high frequency of anastomotic leakages. After diclofenac was removed from the postoperative analgesic regimen, the frequency dropped. This study aimed to evaluate the influence of diclofenac on the risk of developing anastomotic...... leakage after laparoscopic colorectal surgery. METHODS: This was a retrospective case-control study based on 75 consecutive patients undergoing laparoscopic colorectal resection with primary anastomosis. In period 1, patients received diclofenac 150 mg/day. In period 2, diclofenac was withdrawn...... and the patients received an opioid analgesic instead. The primary outcome parameter was clinically significant anastomotical leakage verified at reoperation. RESULTS: 1/42 patients in the no-diclofenac group compared with 7/33 in the diclofenac group had an anastomotic leakage after operation (p = 0...

  1. Compilation of current literature on seals, closures, and leakage for radioactive material packagings

    International Nuclear Information System (INIS)

    Warrant, M.M.; Ottinger, C.A.

    1989-01-01

    This report presents an overview of the features that affect the sealing capability of radioactive material packagings currently certified by the US Nuclear Regulatory Commission. The report is based on a review of current literature on seals, closures, and leakage for radioactive material packagings. Federal regulations that relate to the sealing capability of radioactive material packagings, as well as basic equations for leakage calculations and some of the available leakage test procedures are presented. The factors which affect the sealing capability of a closure, including the properties of the sealing surfaces, the gasket material, the closure method and the contents are discussed in qualitative terms. Information on the general properties of both elastomer and metal gasket materials and some specific designs are presented. A summary of the seal material, closure method, and leakage tests for currently certified packagings with large diameter seals is provided. 18 figs., 9 tabs

  2. Horizontal H 2-air turbulent buoyant jet resulting from hydrogen leakage

    KAUST Repository

    El-Amin, Mohamed; Sun, Shuyu

    2012-01-01

    The current article is devoted to introducing mathematical and physical analyses with numerical investigation of a buoyant jet resulting from hydrogen leakage in air from a horizontal round source. H 2-air jet is an example of the non

  3. Leakage Account for Radial Face Contact Seal in Aircraft Engine Support

    Science.gov (United States)

    Vinogradov, A. S.; Sergeeva, T. V.

    2018-01-01

    The article is dedicated to the development of a methodology for the radial face contact seal design taking into consideration the supporting elements deformations in different aircraft engine operating modes. Radial face contact seals are popular in the aircraft engines bearing support. However, there are no published leakage calculation methodologies of these seals. Radial face contact seal leakage is determined by the gap clearance in the carbon seal ring split. In turn, the size gap clearance depends on the deformation of the seal assembly parts and from the engine operation. The article shows the leakage detection sequence in the intershaft radial face contact seal of the compressor support for take-off and cruising modes. Evaluated calculated leakage values (2.4 g/s at takeoff and 0.75 g/s at cruising) go with experience in designing seals.

  4. Development of dual field magnetic flux leakage (MFL) inspection technology to detect mechanical damage.

    Science.gov (United States)

    2013-03-01

    This report details the development and testing of a dual magnetization in-line inspection (ILI) : tool for detecting mechanical damage in operating pipelines, including the first field trials of a : fully operational dual-field magnetic flux leakage...

  5. Costa Rica's Presentation to the 1st Workshop on Problems of Leakage in Dams

    International Nuclear Information System (INIS)

    Cordero Calderon, C.F.

    1994-03-01

    This paper includes information about the Instituto Costarricense de Electricidad (ICE); the project T racer Application to Leakage in Dams; the description of the Cachi's Dam and the description of the Arenal's Dam. (S. Grainger)

  6. Hydrogeochemical Impact of CO2 Leakage from Geological Sequestration on Shallow Potable Aquifers

    DEFF Research Database (Denmark)

    Cahill, Aaron Graham

    . Although considered highly unlikely following appropriate site selection, leakage of CO2 from CCGS forms a major concern for both scientists and the public. Leakage would potentially occur through faults or abandoned boreholes and ultimately result in upward migration and discharge to the atmosphere....... During migration CO2 would dissolve into groundwater forming carbonic acid, induce water-rock reactions and thus change groundwater chemistry. Therefore prior to implementation of this potentially necessary technology, environmental risks associated with leakage must be understood. Over the past 10 years...... it be detected geochemically? Some common hydrochemical development is apparent from the literature however many aspects of hydrogeological and hydrogeochemical impact of leakage into shallow aquifers used in water supply remain unclear. In this Ph.D. study an integrated approach was employed in order to answer...

  7. An investigation into the signals leakage from a smartcard based on different runtime code

    CSIR Research Space (South Africa)

    Frieslaar, I

    2015-09-01

    Full Text Available September 2015 at the Arabella Hotel & Spa in the heart of the Kogelberg Biosphere Reserve near Hermanus, Western Cape, South Africa An Investigation into the Signals Leakage From a Smartcard based on Different Runtime Code Ibraheem Frieslaar...

  8. Effect of condenser water in-leakage on steam generator water chemistry

    International Nuclear Information System (INIS)

    Balakrishnan, P.V.

    1978-01-01

    Corrosive environments may be generated within steam genrators from condenser cooling water in-leakage. Theoretical as well as experimental evaluation of the aggressiveness of such environments is being carried out for the condenser-cooling waters used at CANDU-PHW nuclear power stations. Calculations have shown that highly concentrated chloride solutions - acidic in the case of sea-water in-leakage, and alkaline in the rest of the cases considered - would be produced within the steam generator. Experiments in a model boiler showed that sea-water in-leakage caused rapid corrosion of carbon steel components when only AVT (all volatile treatment) was used for water chemistry control. Use of a non-volatile reagent, as in the congruent phosphate treatment, avoided the rapid corrosion of carbon steel. On the basis of our studies, congruent phosphate treatment during sea water in-leakage appears desirable. (author)

  9. A method to investigate inter-aquifer leakage using hydraulics and multiple environmental tracers

    Science.gov (United States)

    Priestley, Stacey; Love, Andrew; Wohling, Daniel; Post, Vincent; Shand, Paul; Kipfer, Rolf; Tyroller, Lina

    2016-04-01

    Informed aquifer management decisions regarding sustainable yields or potential exploitation require an understanding of the groundwater system (Alley et al. 2002, Cherry and Parker 2004). Recently, the increase in coal seam gas (CSG) or shale gas production has highlighted the need for a better understanding of inter-aquifer leakage and contaminant migration. In most groundwater systems, the quantity or location of inter-aquifer leakage is unknown. Not taking into account leakage rates in the analysis of large scale flow systems can also lead to significant errors in the estimates of groundwater flow rates in aquifers (Love et al. 1993, Toth 2009). There is an urgent need for robust methods to investigate inter-aquifer leakage at a regional scale. This study builds on previous groundwater flow and inter-aquifer leakage studies to provide a methodology to investigate inter-aquifer leakage in a regional sedimentary basin using hydraulics and a multi-tracer approach. The methodology incorporates geological, hydrogeological and hydrochemical information in the basin to determine the likelihood and location of inter-aquifer leakage. Of particular benefit is the analysis of hydraulic heads and environmental tracers at nested piezometers, or where these are unavailable bore couplets comprising bores above and below the aquitard of interest within a localised geographical area. The proposed methodology has been successful in investigating inter-aquifer leakage in the Arckaringa Basin, South Australia. The suite of environmental tracers and isotopes used to analyse inter-aquifer leakage included the stable isotopes of water, radiocarbon, chloride-36, 87Sr/86Sr and helium isotopes. There is evidence for inter-aquifer leakage in the centre of the basin ~40 km along the regional flow path. This inter-aquifer leakage has been identified by a slight draw-down in the upper aquifer during pumping in the lower aquifer, overlap in Sr isotopes, δ2H, δ18O and chloride

  10. Leakage of colon anastomoses: development of an experimental model in pigs

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Sørensen, Michael

    2007-01-01

    model has only been developed in one gastric bypass study. The aim of the present study was to develop a leakage model of pig colon anastomoses. This type of study has never been performed before. Materials and Methods: Anastomosis was performed in 22 pigs. In all anastomoses a standardized rupture......: A model of anastomotic leakage on pig colon is developed with creation of a 21-mm rupture in the anastomotic line....

  11. Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kariya, Shuji, E-mail: kariyas@hirakata.kmu.ac.jp; Nakatani, Miyuki, E-mail: nakatanm@hirakata.kmu.ac.jp; Yoshida, Rie, E-mail: yagir@hirakata.kmu.ac.jp; Ueno, Yutaka, E-mail: uenoyut@hirakata.kmu.ac.jp; Komemushi, Atsushi, E-mail: komemush@takii.kmu.ac.jp; Tanigawa, Noboru, E-mail: tanigano@hirakata.kmu.ac.jp [Kansai Medical University, Department of Radiology (Japan)

    2017-01-15

    PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct and leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.

  12. The influence of interband tunneling on leakage current in manganite/titanate heterojunction

    International Nuclear Information System (INIS)

    Han Peng; Jia Jinfeng

    2008-01-01

    The behavior of leakage current at reverse bias in p-La 0.9 Sr 0.1 MnO 3 /n-SrNb 0.01 Ti 0.99 O 3 heterojunction has been theoretically studied by calculating interband tunneling current with various doping densities and temperatures. Our results reveal that the reduction of leakage current with decrease of doping density and increase of temperature originates from properties of interband tunneling

  13. Leakage Risk Assessment for a Potential CO2 Storage Project in Saskatchewan, Canada

    Energy Technology Data Exchange (ETDEWEB)

    Houseworth, J.E.; Oldenburg, C.M.; Mazzoldi, A.; Gupta, A.K.; Nicot, J.-P.; Bryant, S.L.

    2011-05-01

    A CO{sub 2} sequestration project is being considered to (1) capture CO{sub 2} emissions from the Consumers Cooperative Refineries Limited at Regina, Saskatchewan and (2) geologically sequester the captured CO{sub 2} locally in a deep saline aquifer. This project is a collaboration of several industrial and governmental organizations, including the Petroleum Technology Research Centre (PTRC), Sustainable Development Technology Canada (SDTC), SaskEnvironment Go Green Fund, SaskPower, CCRL, Schlumberger Carbon Services, and Enbridge. The project objective is to sequester 600 tonnes CO{sub 2}/day. Injection is planned to start in 2012 or 2013 for a period of 25 years for a total storage of approximately 5.5 million tonnes CO{sub 2}. This report presents an assessment of the leakage risk of the proposed project using a methodology known as the Certification Framework (CF). The CF is used for evaluating CO{sub 2} leakage risk associated with geologic carbon sequestration (GCS), as well as brine leakage risk owing to displacement and pressurization of brine by the injected CO{sub 2}. We follow the CF methodology by defining the entities (so-called Compartments) that could be impacted by CO{sub 2} leakage, the CO{sub 2} storage region, the potential for leakage along well and fault pathways, and the consequences of such leakage. An understanding of the likelihood and consequences of leakage forms the basis for understanding CO{sub 2} leakage risk, and forms the basis for recommendations of additional data collection and analysis to increase confidence in the risk assessment.

  14. Comparison of the Standard of Air Leakage in Current Metal Duct Systems in the World

    Science.gov (United States)

    Di, Yuhui; Wang, Jiqian; Feng, Lu; Li, Xingwu; Hu, Chunlin; Shi, Junshe; Xu, Qingsong; Qiao, Leilei

    2018-01-01

    Based on the requirements of air leakage of metal ducts in Chinese design standards, technical measures and construction standards, this paper compares the development history, the classification of air pressure levels and the air tightness levels of air leakage standards of current Chinese and international metal ducts, sums up the differences, finds shortage by investigating the design and construction status and access to information, and makes recommendations, hoping to help the majority of engineering and technical personnel.

  15. Embolization for Thoracic Duct Collateral Leakage in High-Output Chylothorax After Thoracic Surgery

    International Nuclear Information System (INIS)

    Kariya, Shuji; Nakatani, Miyuki; Yoshida, Rie; Ueno, Yutaka; Komemushi, Atsushi; Tanigawa, Noboru

    2017-01-01

    PurposeThis study was designed to investigate thoracic duct collateral leakage and the supply route of lymphatic fluid by lymphangiography and transcatheter thoracic ductography and to evaluate the results of embolization for thoracic duct collateral leakage performed to cut off this supply route.MethodsData were retrospectively collected from five patients who underwent embolization for thoracic duct collateral leakage in persistent high-output chylothorax after thoracic surgery. Extravasation of lipiodol at the ruptured thoracic duct collaterals was confirmed in all patients on lymphangiography. Transcatheter thoracic ductography was used to identify extravasation of iodinated contrast agent and to identify communication between the thoracic duct and leakage site. Thoracic duct embolization (TDE) was performed using the percutaneous transabdominal approach to cut off the supply route using N-butyl cyanoacrylate (NBCA) mixed with lipiodol (1:5–1:20).ResultsClinical success (drainage volume ≤10 mL/kg/day within 7 days after TDE) was achieved in all patients. The collateral routes developed as consequence of surgical thoracic duct ligation. In three patients, NBCA-Lipiodol reached the leakage site through direct communication between the thoracic duct and the ruptured lymphatic duct. In the other two patients, direct communication and extravasation was not detected on thoracic ductography, and NBCA-Lipiodol did not reach the leakage site. However, NBCA-Lipiodol did reach the cisterna chyli, lumbar trunks, and some collateral routes via the cisterna chyli or lumbar lymphatics. As a result, leakage was stopped.ConclusionsTDE was effective for the management of leakage of the collaterals in high-output chylothorax after thoracic surgery.

  16. Intrathoracic anastomotic leakage after gastroesophageal cancer resection is associated with increased risk of recurrence

    DEFF Research Database (Denmark)

    Kofoed, Steen C; Calatayud, Dan; Jensen, Lone S

    2015-01-01

    OBJECTIVE: Intrathoracic anastomotic leakage after intended curative resection for cancer in the esophagus or gastroesophageal junction has a negative impact on long-term survival. The aim of this study was to investigate whether an anastomotic leakage was associated with an increased recurrence......]: 1.17-2.29, P = .004) and all-cause mortality (HR = 1.57; 95% CI: 1.23-2.05, P cancer resection....

  17. Uncertainty and risk assessment of leakage in water tunnels - a case from Nepal Himalaya

    OpenAIRE

    Panthi, Krishna Kanta; Nilsen, Bjørn

    2008-01-01

    Safety and stability are the key issues in underground excavations. Making tunnels water tight plays an important role in this regards. Water leakage problems in unlined or shotcrete lined water tunnels are not new issues. In many occasions severe water inflow as well as leakage problems have been faced that not only reduced stability of the rock mass surrounding the tunnel, but also valuable water has been lost from it, causing safety risk as well as huge economic loss to the projects. I...

  18. Computing Optimal Mixed Strategies for Terrorist Plot Detection Games with the Consideration of Information Leakage

    OpenAIRE

    Li MingChu; Yang Zekun; Lu Kun; Guo Cheng

    2017-01-01

    The terrorist’s coordinated attack is becoming an increasing threat to western countries. By monitoring potential terrorists, security agencies are able to detect and destroy terrorist plots at their planning stage. Therefore, an optimal monitoring strategy for the domestic security agency becomes necessary. However, previous study about monitoring strategy generation fails to consider the information leakage, due to hackers and insider threat. Such leakage events may lead to failure of watch...

  19. Influence of rain water leakage on the hygrothermal performance of exterior insulation systems

    OpenAIRE

    Künzel, H.M.; Zirkelbach, D.

    2008-01-01

    This investigation shows that ETICS on light weight structures pose no moisture problem in cold and moderate climates when the detailing of joints and openings is well done, i.e. there is no rain water leakage. This holds for all locations investigated. However, if water leakage cannot be excluded completely and therefore the North-American Standard assumptions - penetration of 1% of the driving rain load - are applied this picture changes, making the drying potential an essential feature. Th...

  20. Determination of the Steady State Leakage Current in Structures with Ferroelectric Ceramic Films

    Science.gov (United States)

    Podgornyi, Yu. V.; Vorotilov, K. A.; Sigov, A. S.

    2018-03-01

    Steady state leakage currents have been investigated in capacitor structures with ferroelectric solgel films of lead zirconate titanate (PZT) formed on silicon substrates with a lower Pt electrode. It is established that Pt/PZT/Hg structures, regardless of the PZT film thickness, are characterized by the presence of a rectifying contact similar to p-n junction. The steady state leakage current in the forward direction increases with a decrease in the film thickness and is determined by the ferroelectric bulk conductivity.

  1. Measurement and analysis of leakage neutron energy spectra around the Kinki University Reactor, UTR-KINKI

    CERN Document Server

    Ogawa, Y; Sagawa, H; Tsujimoto, T

    2002-01-01

    The highly sensitive cylindrical multi-moderator type neutron spectrometer was constructed for measurement of low level environmental neutrons. This neutron spectrometer was applied for the determination of leakage neutron energy spectra around the Kinki University Reactor. The analysis of the leakage neutron energy spectra was performed by MCNP Monte Carlo code. From the obtained results, the agreement between the MCNP predictions and the experimentally determined values is fairly good, which indicates the MCNP model is correctly simulating the UTR-KINKI.

  2. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun [Radiation Eng. Center, Shihung (Korea, Republic of); Lee, Dongbum [Academic Support Dept., Seoul (Korea, Republic of)

    2013-05-15

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  3. Preadmission glucocorticoid use and anastomotic leakage after colon and rectal cancer resections: a Danish cohort study

    Science.gov (United States)

    Ostenfeld, Eva Bjerre; Erichsen, Rune; Baron, John A; Thorlacius-Ussing, Ole; Iversen, Lene Hjerrild; Riis, Anders H; Sørensen, Henrik Toft

    2015-01-01

    Objective To examine whether preadmission glucocorticoid use increases the risk of anastomotic leakage after colon and rectal cancer resections. Design A population-based cohort study. Setting Denmark (2001–2011). Participants We identified patients who had undergone a primary anastomosis after a colorectal cancer resection by linking medical registries. Participants who filled their most recent glucocorticoid prescription ≤90, 91–365 and >365 days before their surgery date were categorised as current, recent and former users, respectively. Main outcome measures We calculated 30-day absolute risk of anastomotic leakage and computed ORs using logistic regression models with adjustment for potential confounders. Results Of the 18 190 patients with colon cancer, anastomotic leakage occurred in 1184 (6.5%). Glucocorticoid use overall was not associated with an increased risk of leakage (6.4% vs 6.9% among never-users; OR 1.05; 95% CI 0.89 to 1.23). Categories of oral, inhaled or intestinal-acting glucocorticoids did not greatly affect risk of leakage. Anastomotic leakage occurred in 695 (13.2%) of 5284 patients with rectal cancer. Glucocorticoid use overall slightly increased risk of leakage (14.6% vs 12.8% among never-users; OR 1.36, 95% CI 1.08 to 1.72). Results did not differ significantly within glucocorticoid categories. Conclusions Preadmission glucocorticoids modestly increased the risk of anastomotic leakage mainly after rectal cancer resection. However, absolute risk differences were small and the clinical impact of glucocorticoid use may therefore be limited. PMID:26408282

  4. Sistem Proteksi Arus Bocor Menggunakan Earth Leakage Circuit Breaker Berbasis Arduino

    OpenAIRE

    Syukriyadin, Syukriyadin

    2016-01-01

    Touching a live part of electrical equipment either intentionally or unintentionally can cause an electric shock. The touch can occur directly or indirectly and results in the flow of electric current through the human body to the ground. This electric current is known as the leakage current and can have fatal effects on the human body such as burns, cramps, faint and death. This paper aims to design a prototype protection model of the earth leakage circuit breaker device based on Arduino (EL...

  5. Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%.

    Science.gov (United States)

    Chee, Soon-Phaik

    2005-01-01

    The purpose of this work was to study the incidence of clear corneal wound leakage at the conclusion of standard co-axial phacoemulsification in a prospective observational series of 100 consecutive cataract cases in a single surgeon's institutional practice. At the conclusion of standard co-axial phacoemulsification using a 2.75 mm temporal single plane clear corneal incision with a 1 mm clear corneal side-port incision, the wounds were hydrated and checked for water-tightness. Povidone iodine 5% (P-I) was then evenly dripped over the cornea and the wounds were inspected visually. Any leakage of aqueous observed was recorded. The amount of leakage was graded as small or large from each wound. Leaky wounds were further hydrated and retested with P-I until sealed. Wound integrity was reassessed on the first postoperative day by use of fluorescein. Of the 100 cases, wound leakage was observed for 31 eyes (31%)-ten main incisions, nineteen side-port incisions, and both incisions in two cases. Wound leakage was easily detected as a ribbon of clear fluid streaming from the incision amid a pool of brown solution. Povidone iodine was not observed within the tract in any incision. All wound leakage was small except for one from the main incision and two from the side-port incision. None of the eyes developed wound leakage the day after surgery and none developed endophthalmitis. In conclusion, leakage from clear corneal incisions at the conclusion of phacoemulsification occurs in almost a third of cases, predominantly from the side incision. It is easily detected by use of the P-I test.

  6. Leakage Detection and Estimation Algorithm for Loss Reduction in Water Piping Networks

    Directory of Open Access Journals (Sweden)

    Kazeem B. Adedeji

    2017-10-01

    Full Text Available Water loss through leaking pipes constitutes a major challenge to the operational service of water utilities. In recent years, increasing concern about the financial loss and environmental pollution caused by leaking pipes has been driving the development of efficient algorithms for detecting leakage in water piping networks. Water distribution networks (WDNs are disperse in nature with numerous number of nodes and branches. Consequently, identifying the segment(s of the network and the exact leaking pipelines connected to this segment(s where higher background leakage outflow occurs is a challenging task. Background leakage concerns the outflow from small cracks or deteriorated joints. In addition, because they are diffuse flow, they are not characterised by quick pressure drop and are not detectable by measuring instruments. Consequently, they go unreported for a long period of time posing a threat to water loss volume. Most of the existing research focuses on the detection and localisation of burst type leakages which are characterised by a sudden pressure drop. In this work, an algorithm for detecting and estimating background leakage in water distribution networks is presented. The algorithm integrates a leakage model into a classical WDN hydraulic model for solving the network leakage flows. The applicability of the developed algorithm is demonstrated on two different water networks. The results of the tested networks are discussed and the solutions obtained show the benefits of the proposed algorithm. A noteworthy evidence is that the algorithm permits the detection of critical segments or pipes of the network experiencing higher leakage outflow and indicates the probable pipes of the network where pressure control can be performed. However, the possible position of pressure control elements along such critical pipes will be addressed in future work.

  7. Leakage localisation method in a water distribution system based on sensitivity matrix: methodology and real test

    OpenAIRE

    Pascual Pañach, Josep

    2010-01-01

    Leaks are present in all water distribution systems. In this paper a method for leakage detection and localisation is presented. It uses pressure measurements and simulation models. Leakage localisation methodology is based on pressure sensitivity matrix. Sensitivity is normalised and binarised using a common threshold for all nodes, so a signatures matrix is obtained. A pressure sensor optimal distribution methodology is developed too, but it is not used in the real test. To validate this...

  8. Leakage investigation in an underground cooling water pipeline at a thermal power station using radiotracer technique

    International Nuclear Information System (INIS)

    Khan, I.H.; Din, U.G.; Gul, S.; Farooq, M.; Qureshi, R.M.

    2004-05-01

    The objective of this study was to locate the leakage point(s) in an underground cooling water pipeline of a Thermal Power Station for pre-shutdown planning purposes. The internal diameter of the pipeline was 2240 mm with 12 mm with 12 (mild steel) wall thickness and it was buried under 1.0 meter reinforced concrete and 0.5-1.0 meter soil/sand cover. The volume flow rate of the pipeline was 29043 m/sup 3/hour at 2kg/cm/sup 2/ pressure. The linear speed of water flowing inside the pipeline was around 2 m/sec. This gave rise to a very high volume fast moving system. Radiotracer technique was used to investigate the problem under investigation. About 50 mCi of /sup 131/I radiotracer, in the form of NaI solution, was injected into the system and radiotracer evolution near suspected leakage point(s) was monitored using radiation detectors (NaI, 2 x 2 inch crystal size). Seven detectors were installed around three teeing off pipes (leakage area) inside the plant building and one at the injection point near the pump outlet. On line data acquisition system was used to acquire the radiotracer data. The leakage water was exiting from the floor just along the pipes carrying main flow of water. The time lag between the arrival, at detectors, of radiotracer flowing inside the pipeline and that present in the leakage water (outside the pipeline) was exploited to identify the position of leakage. The tracer test revealed that there was leakage at two points. The leakage at one point was small as compared at the other points. (author)

  9. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    International Nuclear Information System (INIS)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun; Lee, Dongbum

    2013-01-01

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  10. Type of incision does not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage

    DEFF Research Database (Denmark)

    Jensen, Kristian Kiim; Oma, Erling; Harling, Henrik

    2017-01-01

    for anastomotic leakage were included with a median follow-up of 5.4 years. Incisional hernia occurred in 41 of 227 (15.3%) patients undergoing midline incision compared with 14 of 81 (14.7%) following transverse incision, P = 1.00. After adjusting for confounders, there was no association between the type...... not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage....

  11. Passivity of memristive BAM neural networks with leakage and additive time-varying delays

    Science.gov (United States)

    Wang, Weiping; Wang, Meiqi; Luo, Xiong; Li, Lixiang; Zhao, Wenbing; Liu, Linlin; Ping, Yuan

    2018-02-01

    This paper investigates the passivity of memristive bidirectional associate memory neural networks (MBAMNNs) with leakage and additive time-varying delays. Based on some useful inequalities and appropriate Lyapunov-Krasovskii functionals (LKFs), several delay-dependent conditions for passivity performance are obtained in linear matrix inequalities (LMIs). Moreover, the leakage delays as well as additive delays are considered separately. Finally, numerical simulations are provided to demonstrate the feasibility of the theoretical results.

  12. SPACETRAN, Radiation Leakage from Cylinder with ANISN Flux Calculation

    International Nuclear Information System (INIS)

    Cramer, S.N.; Solomito, M.

    1974-01-01

    1 - Nature of physical problem solved: SPACETRAN is designed to calculate the energy-dependent total flux or some proportional quantity such as kerma, due to the radiation leakage from the surface of a right-circular cylinder at detector positions located at arbitrary distances from the surface. The assumptions are made that the radiation emerging from the finite cylinder has no spatial dependence and that a vacuum surrounds the cylinder. 2 - Method of solution: There are three versions of the program in the code package. SPACETRAN-I uses the surface angular fluxes calculated by the discrete ordinates SN code ANISN, as input. SPACETRAN-II assumes that the surface angular flux for all energies can be represented as a function (Cos(PHI))**N, where PHI is the angle between surface outward normal and radiation direction, and N is an integer specified by the user. For both versions the energy group structure and the number and location of detectors is arbitrary. The flux (or response function) for a given energy group at some detection point is computed by summing the contributions from each surface area element over the entire surface. The surface area elements are defined by input data. SPACETRAN-III uses surface angular fluxes from DOT-3. SPACETRAN-I handles contributions either from a cylinder 'end' or 'side', so the total contributions must be obtained by adding the results of separate end and side runs. ANISN angular fluxes are specified for discrete directions. In general, the direction between the detector and contributing area will not exactly coincide with one of these discrete directions. In this case, the ANISN angular flux for the 'closest' discrete direction is used to approximate the contribution to the detector. SPACETRAN-II handles contributions from both the side and end of a cylinder in a single run. Since the assumed angular distribution is specified by a continuous function, it is not necessary to perform the angle selection described above. For

  13. Long-term monitoring of marine gas leakage

    Science.gov (United States)

    Spickenbom, Kai; Faber, Eckhard; Poggenburg, Jürgen; Seeger, Christian; Furche, Markus

    2010-05-01

    The sequestration of CO2 in sub-seabed geological formations is one of the Carbon Capture and Storage (CCS) strategies currently under study. Although offshore operations are significantly more expensive than comparable onshore operations, the growing public resistance against onshore CCS projects makes sub-seabed storage a promising option. Even after a thorough review of the geological setting, there is always the possibility of leakage from the reservoir. As part of the EU-financed project CO2ReMoVe (Research, Monitoring, Verification), which aims to develop innovative research and technologies for monitoring and verification of carbon dioxide geological storage, we are working on the development of submarine long-term gas flow monitoring systems. The basic design of the monitoring system builds on our experience in volcano monitoring. Early prototypes were composed of a raft floating on the surface of a mud volcano, carrying sensors for CO2 flux and concentration, data storage and transmission, and power supply by battery-buffered solar panels. The system was modified for installation in open sea by using a buoy instead of a raft and a funnel on the seafloor to collect the gas, connected by a flexible tube. This setup provides a cost-effective solution for shallow waters. However, a buoy interferes with ship traffic, and it is also difficult to adapt this design to greater water depths. These requirements can best be complied by a completely submersed system. A system for unattended long-term monitoring in a marine environment has to be extremely durable. Therefore, we focussed on developing a mechanically and electrically as simple setup as possible, which has the additional advantage of low cost. The system consists of a funnel-shaped gas collector, a sensor head and pressure housings for electronics and power supply. Since this setup is inexpensive, it can be deployed in numbers to cover larger areas. By addition of multi-channel data loggers, data

  14. Correlation between dislocations and leakage current of p-n diodes on a free-standing GaN substrate

    Science.gov (United States)

    Usami, Shigeyoshi; Ando, Yuto; Tanaka, Atsushi; Nagamatsu, Kentaro; Deki, Manato; Kushimoto, Maki; Nitta, Shugo; Honda, Yoshio; Amano, Hiroshi; Sugawara, Yoshihiro; Yao, Yong-Zhao; Ishikawa, Yukari

    2018-04-01

    Dislocations that cause a reverse leakage current in vertical p-n diodes on a GaN free-standing substrate were investigated. Under a high reverse bias, dot-like leakage spots were observed using an emission microscope. Subsequent cathodoluminescence (CL) observations revealed that the leakage spots coincided with part of the CL dark spots, indicating that some types of dislocation cause reverse leakage. When etch pits were formed on the dislocations by KOH etching, three sizes of etch pits were obtained (large, medium, and small). Among these etch pits, only the medium pits coincided with leakage spots. Additionally, transmission electron microscopy observations revealed that pure screw dislocations are present under the leakage spots. The results revealed that 1c pure screw dislocations are related to the reverse leakage in vertical p-n diodes.

  15. Radionuclide leakage monitoring during hyperthermic isolated limb perfusion for treatment of local melanoma metastasis in an extremity

    DEFF Research Database (Denmark)

    Paulsen, Ida F; Chakera, Annette Hougaard; Schmidt, Grethe

    2015-01-01

    (99m) Tc-labelled tracer infused into the isolated limb circulation. RESULTS: One hundred and sixteen of 131 procedures were completed. In 13%, a leakage of ≥10% was detected; in 6% (n = 8), the cytotoxic drug was never infused because of constant leakage; in 7% (n = 9), leakage ≥10% was measured......INTRODUCTION: The aim is to describe the importance of leakage monitoring in hyperthermic isolated limb perfusion (ILP). It is generally recommended that leakage should not exceed 10% because of risk of systemic toxicity. MATERIAL AND METHODS: Data retrieved by retrospective analysis of 131...... were observed in 14%. Three of the patients with leakage ≥10% were successfully treated in a repeated procedure. CONCLUSION: Leakage monitoring using a threshold of 10% during ILP saves the patients from systemic toxicity, however, at the expense of early termination or cancellation of ILP treatment...

  16. Non-fistulous urinary leakage among women attending a Nigerian family planning clinic

    Directory of Open Access Journals (Sweden)

    Ijaiya MA

    2011-12-01

    Full Text Available Munir'deen A Ijaiya1, Hadijat O Raji1, Abiodun P Aboyeji1, Kike T Adesina1, Idowu O Adebara2, Grace G Ezeoke11Department of Obstetrics and Gynaecology, University of Ilorin Teaching Hospital, Ilorin, Nigeria; 2Department of Obstetrics and Gynaecology, Federal Medical Centre, Ido-Ekiti, NigeriaAbstract: Urinary leakage is an important gynecological challenge, which has a substantial impact on quality of life. The aim of this study was to determine the prevalence and types of non-fistulous urinary leakage among women attending the family planning clinic of the University of Ilorin teaching hospital, Ilorin, Nigeria. The study was a cross-sectional study carried out between January 3 and April 25 2009. One hundred and two women experienced urinary leakage out of 333 women interviewed, giving a prevalence rate of 30.6%. Stress incontinence was the most common urinary leakage (prevalence rate 12.0%. This is followed by urge incontinence (10.8%, urinary incontinence (4.8%, and overflow incontinence (3.0%. None of the women afflicted sought medical help. Conclusively, this study has demonstrated that non-fistulous urinary leakage is a common problem among women of reproductive age in this environment.Keywords: non-fistulous urinary leakage, family planning, women, prevalence, types

  17. Regulatory concerns for leakage testing of packagings with three O-ring closure seals

    International Nuclear Information System (INIS)

    Oras, J.J.; Towell, R.H.; Wangler, M.E.

    1997-01-01

    The American National Standard for Radioactive Materials--Leakage Tests on Packages for Shipment (ANSI N14.5) provides guidance for leakage rate testing to show that a particular packaging complies with regulatory requirements and also provides guidance in determining appropriate acceptance criteria. Recent radioactive packagings designs have incorporated three O-ring closure seals, the middle O-ring being the containment seal. These designs have the potential for false positive results of leakage rate tests. The volume between the containment O-ring and the inner O-ring is used for the helium gas required for the leakage rate tests to reduce both the amount of helium used and the time required to conduct the tests. A leak detector samples the evacuated volume between the outer O-ring and the containment O-ring. False positive results can be caused in two ways, a large leakage in the containment seal or leakage in the inner seal. This paper will describe the problem together with possible solutions/areas that need to be addressed in a Safety Analysis Report for Packagings before a particular packaging design can be certified for transport

  18. Effects of cavity on leakage loss in straight-through labyrinth seals

    International Nuclear Information System (INIS)

    Zhao, W; Nielsen, T K; Billdal, J T

    2010-01-01

    Labyrinth seals are widely used in rotating fluid machinery, due to its low-cost, simplicity and reliability. A straight-through labyrinth seal consists of a clearance between the stator and rotor, and sometimes cavities which are included on the stator or the rotator side. In this type of seals, making cavities are an effective way to convert turbulence kinetic energy into thermal energy by forming turbulence vortices, thereby reducing pressure difference and leakage flow. In this paper, the effect of cavities on leakage loss in straight-through labyrinth seals are studied by changing cavity dimensions such as depth and length, cavity number and cavity location. The influences of unilateral cavities and bilateral cavities on the leakage loss in straight-through labyrinth seals are also compared. The fluid flow characteristics through straight-through labyrinth seals were obtained by using viscous flow analysis along with a standard k-ωturbulence model. The cavity dimensions and cavity numbers have significant effects on the leakage as well as on the flow pattern in the seal. The bilateral cavity has better leakage performance than the unilateral cavity when cavity dimensions are identical. However, the cavity location shows no significant influences on the leakage flow.

  19. The Impact of Gas Turbine Component Leakage Fault on GPA Performance Diagnostics

    Directory of Open Access Journals (Sweden)

    E. L. Ntantis

    2016-01-01

    Full Text Available The leakage analysis is a key factor in determining energy loss from a gas turbine. Once the components assembly fails, air leakage through the opening increases resulting in a performance loss. Therefore, the performance efficiency of the engine cannot be reliably determined, without good estimates and analysis of leakage faults. Consequently, the implementation of a leakage fault within a gas turbine engine model is necessary for any performance diagnostic technique that can expand its diagnostics capabilities for more accurate predictions. This paper explores the impact of gas turbine component leakage fault on GPA (Gas Path Analysis Performance Diagnostics. The analysis is demonstrated with a test case where gas turbine performance simulation and diagnostics code TURBOMATCH is used to build a performance model of a model engine similar to Rolls-Royce Trent 500 turbofan engine, and carry out the diagnostic analysis with the presence of different component fault cases. Conclusively, to improve the reliability of the diagnostic results, a leakage fault analysis of the implemented faults is made. The diagnostic tool used to deal with the analysis of the gas turbine component implemented faults is a model-based method utilizing a non-linear GPA.

  20. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    Science.gov (United States)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.