WorldWideScience

Sample records for transient stability assessment

  1. Transient stability index for online stability assessment and contingency evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ribbens-Pavella, M; Murthy, P G; Horward, J L; Carpentier, J L

    1982-04-01

    An on-line methodology is proposed for assessing the robustness of a power system from the point of view of transient stability, and a scalar expression, the transient stability index, is accordingly derived. The reliability and sensitivity of this index are tested by means of simulations for a number of power system cases. The index is shown to be appropriate for online stability assessment, contingency evaluation and preventive control. 14 refs.

  2. Analytical Assessment for Transient Stability Under Stochastic Continuous Disturbances

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Ping [Hohai Univ., Nanjing (China); Li, Hongyu [Hohai Univ., Nanjing (China); Gan, Chun [The Univ. of Tennessee, Knoxville, TN (United States); Liu, Yong [The Univ. of Tennessee, Knoxville, TN (United States); Yu, Yiping [Hohai Univ., Nanjing (China); Liu, Yilu [Univ. of Tennessee, Knoxville, TN (United States)

    2017-06-28

    Here, with the growing integration of renewable power generation, plug-in electric vehicles, and other sources of uncertainty, increasing stochastic continuous disturbances are brought to power systems. The impact of stochastic continuous disturbances on power system transient stability attracts significant attention. To address this problem, this paper proposes an analytical assessment method for transient stability of multi-machine power systems under stochastic continuous disturbances. In the proposed method, a probability measure of transient stability is presented and analytically solved by stochastic averaging. Compared with the conventional method (Monte Carlo simulation), the proposed method is many orders of magnitude faster, which makes it very attractive in practice when many plans for transient stability must be compared or when transient stability must be analyzed quickly. Also, it is found that the evolution of system energy over time is almost a simple diffusion process by the proposed method, which explains the impact mechanism of stochastic continuous disturbances on transient stability in theory.

  3. Transient stability risk assessment of power systems incorporating wind farms

    DEFF Research Database (Denmark)

    Miao, Lu; Fang, Jiakun; Wen, Jinyu

    2013-01-01

    fed induction generator has been established. Wind penetration variation and multiple stochastic factors of power systems have been considered. The process of transient stability risk assessment based on the Monte Carlo method has been described and a comprehensive risk indicator has been proposed......Large-scale wind farm integration has brought several aspects of challenges to the transient stability of power systems. This paper focuses on the research of the transient stability of power systems incorporating with wind farms by utilizing risk assessment methods. The detailed model of double....... An investigation has been conducted into an improved 10-generator 39-bus system with a wind farm incorporated to verify the validity and feasibility of the risk assessment method proposed....

  4. An Artificial Intelligence Approach to Transient Stability Assessment

    OpenAIRE

    Akella, Vijay Ahaskar; Khincha, HP; Kumar, Sreerama R

    1991-01-01

    An artificial intelligence approach to online transient stability assessment is briefly discussed, and some crucial requirements for this algorithm are identified. Solutions to these are proposed. Some new attributes are suggested so as to reflect machine dynamics and changes in the network. Also a new representative learning set algorithm has been developed.

  5. Impact of Model Detail of Synchronous Machines on Real-time Transient Stability Assessment

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Østergaard, Jacob

    2013-01-01

    In this paper, it is investigated how detailed the model of a synchronous machine needs to be in order to assess transient stability using a Single Machine Equivalent (SIME). The results will show how the stability mechanism and the stability assessment are affected by the model detail. In order...... of the machine models is varied. Analyses of the results suggest that a 4th-order model may be sufficient to represent synchronous machines in transient stability studies....

  6. Probabilistic assessment of power system transient stability incorporating SMES

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Jiakun, E-mail: Jiakun.Fang@gmail.com [State Key Lab of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, No. 1037, Luoyu Road, Wuhan 430074 (China); Yao, Wei [State Key Lab of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, No. 1037, Luoyu Road, Wuhan 430074 (China); Wen, Jinyu, E-mail: jinyu.wen@hust.edu.cn [State Key Lab of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, No. 1037, Luoyu Road, Wuhan 430074 (China); Cheng, Shijie; Tang, Yuejin; Cheng, Zhuo [State Key Lab of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, No. 1037, Luoyu Road, Wuhan 430074 (China)

    2013-01-15

    Highlights: ► Probabilistic study of power system with wind farm and SMES is proposed. ► Quantitative relationship between system stability and SMES capacity is given. ► System stability increases with the capacity of the SMES. ► System stability decreases with the penetration of wind power. ► Together with the cost function, the coil size is optimized. -- Abstract: This paper presents a stochastic-based approach to evaluate the probabilistic transient stability index of the power system incorporating the wind farm and the SMES. Uncertain factors include both sequence of disturbance in power grid and stochastic generation of the wind farm. The spectrums of disturbance in the grid as the fault type, the fault location, the fault clearing time and the automatic reclosing process with their probabilities of occurrence are used to calculate the probability indices, while the wind speed statistics and parameters of the wind generator are used in a Monte Carlo simulation to generate samples for the studies. With the proposed method, system stability is ”measured”. Quantitative relationship of penetration level, SMES coil size and system stability is established. Considering the stability versus coil size to be the production curve, together with the cost function, the coil size is optimized economically.

  7. Probabilistic assessment of power system transient stability incorporating SMES

    International Nuclear Information System (INIS)

    Fang, Jiakun; Yao, Wei; Wen, Jinyu; Cheng, Shijie; Tang, Yuejin; Cheng, Zhuo

    2013-01-01

    Highlights: ► Probabilistic study of power system with wind farm and SMES is proposed. ► Quantitative relationship between system stability and SMES capacity is given. ► System stability increases with the capacity of the SMES. ► System stability decreases with the penetration of wind power. ► Together with the cost function, the coil size is optimized. -- Abstract: This paper presents a stochastic-based approach to evaluate the probabilistic transient stability index of the power system incorporating the wind farm and the SMES. Uncertain factors include both sequence of disturbance in power grid and stochastic generation of the wind farm. The spectrums of disturbance in the grid as the fault type, the fault location, the fault clearing time and the automatic reclosing process with their probabilities of occurrence are used to calculate the probability indices, while the wind speed statistics and parameters of the wind generator are used in a Monte Carlo simulation to generate samples for the studies. With the proposed method, system stability is ”measured”. Quantitative relationship of penetration level, SMES coil size and system stability is established. Considering the stability versus coil size to be the production curve, together with the cost function, the coil size is optimized economically

  8. Strategies for Voltage Control and Transient Stability Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Hiskens, Ian A.

    2013-09-25

    As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of

  9. Transient Stability Assessment of Power System with Large Amount of Wind Power Penetration

    DEFF Research Database (Denmark)

    Liu, Leo; Chen, Zhe; Bak, Claus Leth

    2012-01-01

    Recently, the security and stability of power system with large amount of wind power are the concerned issues, especially the transient stability. In Denmark, the onshore and offshore wind farms are connected to distribution system and transmission system respectively. The control and protection...... methodologies of onshore and offshore wind farms definitely affect the transient stability of power system. In this paper, the onshore and offshore wind farms are modeled in detail in order to assess the transient stability of western Danish power system. Further, the computation of critical clearing time (CCT...... plants, load consumption level and high voltage direct current (HVDC) transmission links are taken into account. The results presented in this paper are able to provide an early awareness of power system security condition of the western Danish power system....

  10. Transient Stability Assessment of Power Systems With Uncertain Renewable Generation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Villegas Pico, Hugo Nestor [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Aliprantis, Dionysios C. [Purdue University; Lin, Xiaojun [Purdue University

    2017-08-09

    The transient stability of a power system depends heavily on its operational state at the moment of a fault. In systems where the penetration of renewable generation is significant, the dispatch of the conventional fleet of synchronous generators is uncertain at the time of dynamic security analysis. Hence, the assessment of transient stability requires the solution of a system of nonlinear ordinary differential equations with unknown initial conditions and inputs. To this end, we set forth a computational framework that relies on Taylor polynomials, where variables are associated with the level of renewable generation. This paper describes the details of the method and illustrates its application on a nine-bus test system.

  11. Investigation of the Adaptability of Transient Stability Assessment Methods to Real-Time Operation

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Sommer, Stefan

    2012-01-01

    In this paper, an investigation of the adaptability of available transient stability assessment methods to real-time operation and their real-time performance is carried out. Two approaches based on Lyapunov’s method and the equal area criterion are analyzed. The results allow to determine...

  12. Investigation of the Adaptability of Transient Stability Assessment Methods to Real-Time Operation

    OpenAIRE

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Sommer, Stefan; Østergaard, Jacob

    2012-01-01

    In this paper, an investigation of the adaptability of available transient stability assessment methods to real-time operation and their real-time performance is carried out. Two approaches based on Lyapunov’s method and the equal area criterion are analyzed. The results allow to determine the runtime of each method with respect to the number of inputs. Furthermore, it allows to identify, which method is preferable in case of changes in the power system such as the integration of distributed ...

  13. A Multifeature Fusion Approach for Power System Transient Stability Assessment Using PMU Data

    Directory of Open Access Journals (Sweden)

    Yang Li

    2015-01-01

    Full Text Available Taking full advantage of synchrophasors provided by GPS-based wide-area measurement system (WAMS, a novel VBpMKL-based transient stability assessment (TSA method through multifeature fusion is proposed in this paper. First, a group of classification features reflecting the transient stability characteristics of power systems are extracted from synchrophasors, and according to the different stages of the disturbance process they are broken into three nonoverlapped subsets; then a VBpMKL-based TSA model is built using multifeature fusion through combining feature spaces corresponding to each feature subset; and finally application of the proposed model to the IEEE 39-bus system and a real-world power system is demonstrated. The novelty of the proposed approach is that it improves the classification accuracy and reliability of TSA using multifeature fusion with synchrophasors. The application results on the test systems verify the effectiveness of the proposal.

  14. An Improved On-line Contingency Screening for Power System Transient Stability Assessment

    DEFF Research Database (Denmark)

    Weckesser, Johannes Tilman Gabriel; Jóhannsson, Hjörtur; Glavic, Mevludin

    2017-01-01

    This paper presents a contingency screening method and a framework for its on-line implementation. The proposed method carries out contingency screening and on-line stability assessment with respect to first-swing transient stability. For that purpose, it utilizes the single machine equivalent...... method and aims at improving the prior developed contingency screening approaches. In order to determine vulnerability of the system with respect to a particular contingency, only one time-domain simulation needs to be performed. An early stop criteria is proposed so that in a majority of the cases...... the simulation can be terminated after a few hundred milliseconds of simulated system response. The method's outcome is an assessment of the system's stability and a classification of each considered contingency. The contingencies are categorized by exploiting parameters of an equivalent one machine infinite bus...

  15. Stability of Ignition Transients

    OpenAIRE

    V.E. Zarko

    1991-01-01

    The problem of ignition stability arises in the case of the action of intense external heat stimuli when, resulting from the cut-off of solid substance heating, momentary ignition is followed by extinction. Physical pattern of solid propellant ignition is considered and ignition criteria available in the literature are discussed. It is shown that the above mentioned problem amounts to transient burning at a given arbitrary temperature distribution in the condensed phase. A brief survey...

  16. Transient Dynamics of Electric Power Systems: Direct Stability Assessment and Chaotic Motions

    Science.gov (United States)

    Chu, Chia-Chi

    A power system is continuously experiencing disturbances. Analyzing, predicting, and controlling transient dynamics, which describe transient behaviors of the power system following disturbances, is a major concern in the planning and operation of a power utility. Important conclusions and decisions are made based on the result of system transient behaviors. As today's power network becomes highly interconnected and much more complex, it has become essential to enhance the fundamental understanding of transient dynamics, and to develop fast and reliable computational algorithms. In this thesis, we emphasize mathematical rigor rather than physical insight. Nonlinear dynamical system theory is applied to study two fundamental topics: direct stability assessment and chaotic motions. Conventionally, power system stability is determined by calculating the time-domain transient behaviors for a given disturbance. In contrast, direct methods identify whether or not the system will remain stable once the disturbance is removed by comparing the corresponding energy value of the post-fault system to a calculated threshold value. Direct methods not only avoid the time-consuming numerical integration of the time domain approach, but also provide a quantitative measure of the degree of system stability. We present a general framework for the theoretical foundations of direct methods. Canonical representations of network-reduction models as well as network-preserving models are proposed to facilitate the analysis and the construction of energy functions of various power system models. An advanced and practical method, called the boundary of stability region based controlling unstable equilibrium point method (BCU method), of computing the controlling unstable equilibrium point is proposed along with its theoretical foundation. Numerical solution algorithms capable of supporting on-line applications of direct methods are provided. Further possible improvements and enhancements are

  17. Rule Extraction Based on Extreme Learning Machine and an Improved Ant-Miner Algorithm for Transient Stability Assessment.

    Science.gov (United States)

    Li, Yang; Li, Guoqing; Wang, Zhenhao

    2015-01-01

    In order to overcome the problems of poor understandability of the pattern recognition-based transient stability assessment (PRTSA) methods, a new rule extraction method based on extreme learning machine (ELM) and an improved Ant-miner (IAM) algorithm is presented in this paper. First, the basic principles of ELM and Ant-miner algorithm are respectively introduced. Then, based on the selected optimal feature subset, an example sample set is generated by the trained ELM-based PRTSA model. And finally, a set of classification rules are obtained by IAM algorithm to replace the original ELM network. The novelty of this proposal is that transient stability rules are extracted from an example sample set generated by the trained ELM-based transient stability assessment model by using IAM algorithm. The effectiveness of the proposed method is shown by the application results on the New England 39-bus power system and a practical power system--the southern power system of Hebei province.

  18. On-line transient stability assessment of large-scale power systems by using ball vector machines

    International Nuclear Information System (INIS)

    Mohammadi, M.; Gharehpetian, G.B.

    2010-01-01

    In this paper ball vector machine (BVM) has been used for on-line transient stability assessment of large-scale power systems. To classify the system transient security status, a BVM has been trained for all contingencies. The proposed BVM based security assessment algorithm has very small training time and space in comparison with artificial neural networks (ANN), support vector machines (SVM) and other machine learning based algorithms. In addition, the proposed algorithm has less support vectors (SV) and therefore is faster than existing algorithms for on-line applications. One of the main points, to apply a machine learning method is feature selection. In this paper, a new Decision Tree (DT) based feature selection technique has been presented. The proposed BVM based algorithm has been applied to New England 39-bus power system. The simulation results show the effectiveness and the stability of the proposed method for on-line transient stability assessment procedure of large-scale power system. The proposed feature selection algorithm has been compared with different feature selection algorithms. The simulation results demonstrate the effectiveness of the proposed feature algorithm.

  19. Rule Extraction Based on Extreme Learning Machine and an Improved Ant-Miner Algorithm for Transient Stability Assessment.

    Directory of Open Access Journals (Sweden)

    Yang Li

    Full Text Available In order to overcome the problems of poor understandability of the pattern recognition-based transient stability assessment (PRTSA methods, a new rule extraction method based on extreme learning machine (ELM and an improved Ant-miner (IAM algorithm is presented in this paper. First, the basic principles of ELM and Ant-miner algorithm are respectively introduced. Then, based on the selected optimal feature subset, an example sample set is generated by the trained ELM-based PRTSA model. And finally, a set of classification rules are obtained by IAM algorithm to replace the original ELM network. The novelty of this proposal is that transient stability rules are extracted from an example sample set generated by the trained ELM-based transient stability assessment model by using IAM algorithm. The effectiveness of the proposed method is shown by the application results on the New England 39-bus power system and a practical power system--the southern power system of Hebei province.

  20. The qualitative criterion of transient angle stability

    DEFF Research Database (Denmark)

    Lyu, R.; Xue, Y.; Xue, F.

    2015-01-01

    In almost all the literatures, the qualitative assessment of transient angle stability extracts the angle information of generators based on the swing curve. As the angle (or angle difference) of concern and the threshold value rely strongly on the engineering experience, the validity and robust...... of these criterions are weak. Based on the stability mechanism from the extended equal area criterion (EEAC) theory and combining with abundant simulations of real system, this paper analyzes the criterions in most literatures and finds that the results could be too conservative or too optimistic. It is concluded...

  1. A Decision Support Tool for Transient Stability Preventive Control

    DEFF Research Database (Denmark)

    Pertl, Michael; Weckesser, Johannes Tilman Gabriel; Rezkalla, Michel M.N.

    2017-01-01

    The paper presents a decision support tool for transient stability preventive control contributing to increased situation awareness of control room operators by providing additional information about the state of the power system in terms of transient stability. A time-domain approach is used...... a predefined minimum critical clearing time for faults at all buses is proposed, while costs are minimized. The results of the assessment are presented to the control room operator, who decides to accept the suggested dispatch or to repeat the assessment considering additional user-specific constraints...

  2. HVDC-System-Interaction Assessment through Line-Flow Change-Distribution Factor and Transient-Stability Analysis at Planning Stage

    Directory of Open Access Journals (Sweden)

    Sungchul Hwang

    2016-12-01

    Full Text Available Many of the recent projects for new transmission line have considered the high-voltage direct current (HVDC system, owing to the many advantages of the direct current (DC system. The most noteworthy advantage is that a cable can serve as a substitute for the overhead transmission line in residential areas; therefore, the HVDC system application is increasing, and as the number of DC systems in the power system increases, the interaction assessment regarding the HVDC system gains importance. An index named multi-infeed interaction factor (MIIF is commonly used to estimate the interaction between power converters; however, the HVDC system is composed of two converters and a transmission line. The MIIF represents the interaction between the rectifiers and inverters, but not for the whole system. In this work, a method to assess the interaction of the whole system was therefore studied. To decide on the location of the new HVDC transmission system at the planning stage, in consideration of the interaction of the existing DC system, the line flow change distribution factor, according to the HVDC-transmission capacity change, was examined. Also, a power system transient -stability analysis was performed with different HVDC system locations, depending on the distribution factor. The simulation results indicate that when the factor is higher, two HVDC systems have a stronger interaction and are less stable in the transient state.

  3. NUMEL: a computer aided design suite for the assessment of the steady state, static/dynamic stability and transient responses of nuclear steam generators

    International Nuclear Information System (INIS)

    Rowe, D.; Lightfoot, P.

    1988-02-01

    NUMEL is a computer aided design suite for the assessment of the steady state, static/dynamic stability and transient responses of nuclear steam generators. The equations solved are those of a monotube coflow or counterflow heat exchanger. The advantages of NUMEL are its fast execution speed, robustness, extensive validation and flexibility coupled with ease of use. The code can simultaneously model up to four separate sections (e.g. reheater, HP boiler). This document is a user manual and describes in detail the running of the NUMEL suite. In addition, a discussion is presented of the necessary approximations involved in representing a serpentine or helical AGR boiler as a monotube counterflow heat exchanger. To date, NUMEL has been applied to the modelling of AGR, Fast Reactor and once through Magnox and conventional boilers. Other versions of the code are available for specialist applications, e.g. Magnox and conventional recirculation boilers. (author)

  4. Simulation of SBWR startup transient and stability

    International Nuclear Information System (INIS)

    Cheng, H.S.; Khan, H.J.; Rohatgi, U.S.

    1998-01-01

    The Simplified Boiling Water Reactor (SBWR) designed by General Electric is a natural circulation reactor with enhanced safety features for potential accidents. It has a strong coupling between power and flow in the reactor core, hence the neutronic coupling with thermal-hydraulics is specially important. The potential geysering instability during the early part of a SBWR startup at low flow, low power and low pressure is of particular concern. The RAMONA-4B computer code developed at Brookhaven National Laboratory (BNL) for the SBWR has been used to simulate a SBWR startup transient and evaluate its stability, using a simplified four-channel representation of the reactor core for the thermal-hydraulics. This transient was run for 20,000 sec (5.56 hrs) in order to cover the essential aspect of the SBWR startup. The simulation showed that the SBWR startup was a very challenging event to analyze as it required accurate modeling of the thermal-hydraulics at low pressures. This analysis did not show any geysering instability during the startup, following the startup procedure as proposed by GE

  5. Effects of agmatine on blood-brain barrier stabilization assessed by permeability MRI in a rat model of transient cerebral ischemia.

    Science.gov (United States)

    Ahn, S S; Kim, S H; Lee, J E; Ahn, K J; Kim, D J; Choi, H S; Kim, J; Shin, N-Y; Lee, S-K

    2015-02-01

    BBB disruption after acute ischemic stroke and subsequent permeability increase may be enhanced by reperfusion. Agmatine has been reported to attenuate BBB disruption. Our aim was to evaluate the effects of agmatine on BBB stabilization in a rat model of transient cerebral ischemia by using permeability dynamic contrast-enhanced MR imaging at early stages and subsequently to demonstrate the feasibility of dynamic contrast-enhanced MR imaging for the investigation of new therapies. Thirty-four male Sprague-Dawley rats were subjected to transient MCA occlusion for 90 minutes. Immediately after reperfusion, agmatine (100 mg/kg) or normal saline was injected intraperitoneally into the agmatine-treated group (n = 17) or the control group, respectively. MR imaging was performed after reperfusion. For quantitative analysis, regions of interest were defined within the infarct area, and values for volume transfer constant, rate transfer coefficient, volume fraction of extravascular extracellular space, and volume fraction of blood plasma were obtained. Infarct volume, infarct growth, quantitative imaging parameters, and numbers of factor VIII-positive cells after immunohistochemical staining were compared between control and agmatine-treated groups. Among the permeability parameters, volume transfer constant and volume fraction of extravascular extracellular space were significantly lower in the agmatine-treated group compared with the control group (0.05 ± 0.02 minutes(-1) versus 0.08 ± 0.03 minute(-1), P = .012, for volume transfer constant and 0.12 ± 0.06 versus 0.22 ± 0.15, P = .02 for volume fraction of extravascular extracellular space). Other permeability parameters were not significantly different between the groups. The number of factor VIII-positive cells was less in the agmatine-treated group than in the control group (3-fold versus 4-fold, P = .037). In ischemic stroke, agmatine protects the BBB, which can be monitored in vivo by quantification of

  6. Shallow landslide stability computation using a distributed transient response model for susceptibility assessment and validation. A case study from Ribeira Quente valley (S. Miguel island, Azores)

    Science.gov (United States)

    Amaral, P.; Marques, R.; Zêzere, J. L.; Marques, F.; Queiroz, G.

    2009-04-01

    In the last 15 years, several heavy rainstorms have occurred in Povoação County (S. Miguel Island, Azores), namely in the Ribeira Quente Valley. These rainfall events have triggered hundreds of shallow landslides that killed tens of people and have been responsible for direct and indirect damages amounting to tens of millions of Euros. On the 6th March 2005 an intense rainfall episode, up to 160 mm of rain in less than 24 h, triggered several shallow landslides that caused 3 victims and damaged/blocked roads. The Ribeira Quente Valley has an area of about 9.5 km2 and is mainly constituted by pyroclastic materials (pumice ash and lapilli), that were produced by the Furnas Volcano explosive eruptions. To provide an assessment of slope-failure conditions for the 6th March 2005 rainfall event, it was applied a distributed transient response model for slope stability analysis. The adopted methodology is a modified version of Iversońs (2000) transient response model, which couple an infinite slope stability analysis with an analytic solution of the Richard's equation for vertical water infiltration in quasi-saturated soil. The validation was made on two different scales: (1) at a slope scale, using two distinct test sites where landslides were triggered; and (2) at the basin scale, using the entire landslide database and generalizing the modeling input parameters for the regional spatialization of results. At the slope scale, the obtained results were very accurate, and it was possible to predict the precise time of the slope failures. At the basin scale, the obtained results were very conservative, even though the model predicted all the observed landslide locations, in the 23.7% of the area classified as untable at the time of the slope failures. This methodology revealed to be a reasonable tool for landslide forecast for both temporal and spatial distributions, on both slope and regional scales. In the future, the model components will be integrated into a GIS

  7. Stability of infinite slopes under transient partially saturated seepage conditions

    Science.gov (United States)

    Godt, Jonathan W.; ŞEner-Kaya, BaşAk; Lu, Ning; Baum, Rex L.

    2012-05-01

    Prediction of the location and timing of rainfall-induced shallow landslides is desired by organizations responsible for hazard management and warnings. However, hydrologic and mechanical processes in the vadose zone complicate such predictions. Infiltrating rainfall must typically pass through an unsaturated layer before reaching the irregular and usually discontinuous shallow water table. This process is dynamic and a function of precipitation intensity and duration, the initial moisture conditions and hydrologic properties of the hillside materials, and the geometry, stratigraphy, and vegetation of the hillslope. As a result, pore water pressures, volumetric water content, effective stress, and thus the propensity for landsliding vary over seasonal and shorter time scales. We apply a general framework for assessing the stability of infinite slopes under transient variably saturated conditions. The framework includes profiles of pressure head and volumetric water content combined with a general effective stress for slope stability analysis. The general effective stress, or suction stress, provides a means for rigorous quantification of stress changes due to rainfall and infiltration and thus the analysis of slope stability over the range of volumetric water contents and pressure heads relevant to shallow landslide initiation. We present results using an analytical solution for transient infiltration for a range of soil texture and hydrological properties typical of landslide-prone hillslopes and show the effect of these properties on the timing and depth of slope failure. We follow by analyzing field-monitoring data acquired prior to shallow landslide failure of a hillside near Seattle, Washington, and show that the timing of the slide was predictable using measured pressure head and volumetric water content and show how the approach can be used in a forward manner using a numerical model for transient infiltration.

  8. Transient stability of wind turbines connected to a power grid

    Energy Technology Data Exchange (ETDEWEB)

    Counan, C.; Juston, P.; Testud, G.

    1986-09-01

    A wind turbine generator model has been adapted for digital simulation using the E.D.F. transient stability program. Component models of the wind generator are described and computed results are provided.

  9. Congestion management enhancing transient stability of power systems

    International Nuclear Information System (INIS)

    Esmaili, Masoud; Shayanfar, Heidar Ali; Amjady, Nima

    2010-01-01

    In a competitive electricity market, where market parties try to maximize their profits, it is necessary to keep an acceptable level of power system security to retain the continuity of electricity services to customers at a reasonable cost. Congestion in a power system is turned up due to network limits. After relieving congestion, the network may be operated with a reduced transient stability margin because of increasing the contribution of risky participants. In this paper, a novel congestion management method based on a new transient stability criterion is introduced. Using the sensitivity of corrected transient stability margin with respect to generations and demands, the proposed method so alleviates the congestion that the network can more retain its transient security compared with earlier methods. The proposed transient stability index is constructed considering the likelihood of credible faults. Indeed, market parties participate by their security-effective bids rather than raw bids. Results of testing the proposed method along with the earlier ones on the New-England test system elaborate the efficiency of the proposed method from the viewpoint of providing a better transient stability margin with a lower security cost. (author)

  10. Transient stability with grid connection and wind turbine drive-train effects

    DEFF Research Database (Denmark)

    Fajardo-R, Luis A.; Medina, Aurelio; Iov, Florin

    2009-01-01

    This paper assesses transient stability of grid-connected wind turbines, combining grid-connection, wind turbine flexibility, and induction generator stability features. Through a grid-connected 2 MW wind turbine cage-generator, the investigation is conducted to identify the critical clearing time...

  11. Argonne program to assess superconducting stability

    International Nuclear Information System (INIS)

    Wang, S.T.; Turner, L.R.; Huang, Y.C.; Dawson, J.W.; Harrang, J.; Hilal, M.A.; Lieberg, M.; Gonczy, J.D.; Kim, S.H.

    1978-01-01

    To assess superconductor stability, a complete program is developed to obtain basic information on the effects of local mechanical perturbations on the cryostatic stability. An analytical model for computing the transient recovery following the mechanical perturbation is developed. A test program is undertaken to develop data needed to verify the conclusions reached through the analytical studies

  12. Transient Thermal Stability of Polymer Nanocomposites

    Science.gov (United States)

    2012-08-01

    modified Montmorillonite, Nanocor masterbatch ) 1 wt % carbon black (Na,Ca)0.33(Al,Mg)2(Si4O10)(OH)2·nH2O Multiwalled Carbon Nanotubes (Nanocyl... masterbatch ) Twin screw extrusion (190C) Slow Heating Regime Thermogravimetric Analysis Nanospecies improve thermal stability as expected Laser

  13. Dynamic remedial action scheme using online transient stability analysis

    Science.gov (United States)

    Shrestha, Arun

    Economic pressure and environmental factors have forced the modern power systems to operate closer to their stability limits. However, maintaining transient stability is a fundamental requirement for the operation of interconnected power systems. In North America, power systems are planned and operated to withstand the loss of any single or multiple elements without violating North American Electric Reliability Corporation (NERC) system performance criteria. For a contingency resulting in the loss of multiple elements (Category C), emergency transient stability controls may be necessary to stabilize the power system. Emergency control is designed to sense abnormal conditions and subsequently take pre-determined remedial actions to prevent instability. Commonly known as either Remedial Action Schemes (RAS) or as Special/System Protection Schemes (SPS), these emergency control approaches have been extensively adopted by utilities. RAS are designed to address specific problems, e.g. to increase power transfer, to provide reactive support, to address generator instability, to limit thermal overloads, etc. Possible remedial actions include generator tripping, load shedding, capacitor and reactor switching, static VAR control, etc. Among various RAS types, generation shedding is the most effective and widely used emergency control means for maintaining system stability. In this dissertation, an optimal power flow (OPF)-based generation-shedding RAS is proposed. This scheme uses online transient stability calculation and generator cost function to determine appropriate remedial actions. For transient stability calculation, SIngle Machine Equivalent (SIME) technique is used, which reduces the multimachine power system model to a One-Machine Infinite Bus (OMIB) equivalent and identifies critical machines. Unlike conventional RAS, which are designed using offline simulations, online stability calculations make the proposed RAS dynamic and adapting to any power system

  14. Transient stability analysis of a distribution network with distributed generators

    NARCIS (Netherlands)

    Xyngi, I.; Ishchenko, A.; Popov, M.; Sluis, van der L.

    2009-01-01

    This letter describes the transient stability analysis of a 10-kV distribution network with wind generators, microturbines, and CHP plants. The network being modeled in Matlab/Simulink takes into account detailed dynamic models of the generators. Fault simulations at various locations are

  15. Advanced methods for BWR transient and stability analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, A; Wehle, F; Opel, S; Velten, R [AREVA, AREVA NP, Erlangen (Germany)

    2008-07-01

    The design of advanced Boiling Water Reactor (BWR) fuel assemblies and cores is governed by the basic requirement of safe, reliable and flexible reactor operation with optimal fuel utilization. AREVA NP's comprehensive steady state and transient BWR methodology allows the designer to respond quickly and effectively to customer needs. AREVA NP uses S-RELAP5/RAMONA as the appropriate methodology for the representation of the entire plant. The 3D neutron kinetics and thermal-hydraulics code has been developed for the prediction of system, fuel and core behavior and provides additional margins for normal operation and transients. Of major importance is the extensive validation of the methodology. The validation is based on measurements at AREVA NP's test facilities, and comparison of the predictions with a great wealth of measured data gathered from BWR plants during many years of operation. Three of the main fields of interest are stability analysis, operational transients and reactivity initiated accidents (RIAs). The introduced 3D methodology for operational transients shows significant margin regarding the operational limit of critical power ratio, which has been approved by the German licensing authority. Regarding BWR stability a large number of measurements at different plants under various conditions have been performed and successfully post-calculated with RAMONA. This is the basis of reliable pre-calculations of the locations of regional and core-wide stability boundaries. (authors)

  16. Advanced methods for BWR transient and stability analysis

    International Nuclear Information System (INIS)

    Schmidt, A.; Wehle, F.; Opel, S.; Velten, R.

    2008-01-01

    The design of advanced Boiling Water Reactor (BWR) fuel assemblies and cores is governed by the basic requirement of safe, reliable and flexible reactor operation with optimal fuel utilization. AREVA NP's comprehensive steady state and transient BWR methodology allows the designer to respond quickly and effectively to customer needs. AREVA NP uses S-RELAP5/RAMONA as the appropriate methodology for the representation of the entire plant. The 3D neutron kinetics and thermal-hydraulics code has been developed for the prediction of system, fuel and core behavior and provides additional margins for normal operation and transients. Of major importance is the extensive validation of the methodology. The validation is based on measurements at AREVA NP's test facilities, and comparison of the predictions with a great wealth of measured data gathered from BWR plants during many years of operation. Three of the main fields of interest are stability analysis, operational transients and reactivity initiated accidents (RIAs). The introduced 3D methodology for operational transients shows significant margin regarding the operational limit of critical power ratio, which has been approved by the German licensing authority. Regarding BWR stability a large number of measurements at different plants under various conditions have been performed and successfully post-calculated with RAMONA. This is the basis of reliable pre-calculations of the locations of regional and core-wide stability boundaries. (authors)

  17. A robust nonlinear stabilizer as a controller for improving transient stability in micro-grids.

    Science.gov (United States)

    Azimi, Seyed Mohammad; Afsharnia, Saeed

    2017-01-01

    This paper proposes a parametric-Lyapunov approach to the design of a stabilizer aimed at improving the transient stability of micro-grids (MGs). This strategy is applied to electronically-interfaced distributed resources (EI-DRs) operating with a unified control configuration applicable to all operational modes (i.e. grid-connected mode, islanded mode, and mode transitions). The proposed approach employs a simple structure compared with other nonlinear controllers, allowing ready implementation of the stabilizer. A new parametric-Lyapunov function is proposed rendering the proposed stabilizer more effective in damping system transition transients. The robustness of the proposed stabilizer is also verified based on both time-domain simulations and mathematical proofs, and an ultimate bound has been derived for the frequency transition transients. The proposed stabilizer operates by deploying solely local information and there are no needs for communication links. The deteriorating effects of the primary resource delays on the transient stability are also treated analytically. Finally, the effectiveness of the proposed stabilizer is evaluated through time-domain simulations and compared with the recently-developed stabilizers performed on a multi-resource MG. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Impact of wind farms with energy storage on transient stability

    Science.gov (United States)

    Bowman, Douglas Allen

    Today's energy infrastructure will need to rapidly expand in terms of reliability and flexibility due to aging infrastructure, changing energy market conditions, projected load increases, and system reliability requirements. Over the few decades, several states in the U.S. are now requiring an increase in wind penetration. These requirements will have impacts on grid reliability given the inherent intermittency of wind generation and much research has been completed on the impact of wind on grid reliability. Energy storage has been proposed as a tool to provide greater levels of reliability; however, little research has occurred in the area of wind with storage and its impact on stability given different possible scenarios. This thesis addresses the impact of wind farm penetration on transient stability when energy storage is added. The results show that battery energy storage located at the wind energy site can improve the stability response of the system.

  19. Wind Power Impact to Transient and Voltage Stability of the Power System in Eastern Denmark

    DEFF Research Database (Denmark)

    Rasmussen, Joana; Jørgensen, Preben; Palsson, Magni Thor

    2005-01-01

    Voltage stability, transient stability and reactive power compensation are extremely important issues for largescale integration of wind power in areas distant from the main transmission system in Eastern Denmark. This paper describes the application of a dynamic wind farm model in simulation...... studies for assessments of a large wind power penetration. The simulation results reveal problems with voltage stability due to the characteristic of wind turbine generation as well as the inability of the power system to meet the reactive power demand. Furthermore, the established model is applied...

  20. Optimal Subinterval Selection Approach for Power System Transient Stability Simulation

    Directory of Open Access Journals (Sweden)

    Soobae Kim

    2015-10-01

    Full Text Available Power system transient stability analysis requires an appropriate integration time step to avoid numerical instability as well as to reduce computational demands. For fast system dynamics, which vary more rapidly than what the time step covers, a fraction of the time step, called a subinterval, is used. However, the optimal value of this subinterval is not easily determined because the analysis of the system dynamics might be required. This selection is usually made from engineering experiences, and perhaps trial and error. This paper proposes an optimal subinterval selection approach for power system transient stability analysis, which is based on modal analysis using a single machine infinite bus (SMIB system. Fast system dynamics are identified with the modal analysis and the SMIB system is used focusing on fast local modes. An appropriate subinterval time step from the proposed approach can reduce computational burden and achieve accurate simulation responses as well. The performance of the proposed method is demonstrated with the GSO 37-bus system.

  1. An Effective Distributed Model for Power System Transient Stability Analysis

    Directory of Open Access Journals (Sweden)

    MUTHU, B. M.

    2011-08-01

    Full Text Available The modern power systems consist of many interconnected synchronous generators having different inertia constants, connected with large transmission network and ever increasing demand for power exchange. The size of the power system grows exponentially due to increase in power demand. The data required for various power system applications have been stored in different formats in a heterogeneous environment. The power system applications themselves have been developed and deployed in different platforms and language paradigms. Interoperability between power system applications becomes a major issue because of the heterogeneous nature. The main aim of the paper is to develop a generalized distributed model for carrying out power system stability analysis. The more flexible and loosely coupled JAX-RPC model has been developed for representing transient stability analysis in large interconnected power systems. The proposed model includes Pre-Fault, During-Fault, Post-Fault and Swing Curve services which are accessible to the remote power system clients when the system is subjected to large disturbances. A generalized XML based model for data representation has also been proposed for exchanging data in order to enhance the interoperability between legacy power system applications. The performance measure, Round Trip Time (RTT is estimated for different power systems using the proposed JAX-RPC model and compared with the results obtained using traditional client-server and Java RMI models.

  2. Robotic exoskeleton assessment of transient ischemic attack.

    Directory of Open Access Journals (Sweden)

    Leif Simmatis

    Full Text Available We used a robotic exoskeleton to quantify specific patterns of abnormal upper limb motor behaviour in people who have had transient ischemic attack (TIA. A cohort of people with TIA was recruited within two weeks of symptom onset. All individuals completed a robotic-based assessment of 8 behavioural tasks related to upper limb motor and proprioceptive function, as well as cognitive function. Robotic task performance was compared to a large cohort of controls without neurological impairments corrected for the influence of age. Impairment in people with TIA was defined as performance below the 5th percentile of controls. Participants with TIA were also assessed with the National Institutes of Health Stroke Scale (NIHSS score, Chedoke-McMaster Stroke Assessment (CMSA of the arm, the Behavioural Inattention Test (BIT, the Purdue pegboard test (PPB, and the Montreal Cognitive Assessment (MoCA. Age-related white matter change (ARWMC, prior infarction and cella-media index (CMI were assessed from baseline CT scan that was performed within 24 hours of TIA. Acute infarction was assessed from diffusion-weighted imaging in a subset of people with TIA. Twenty-two people with TIA were assessed. Robotic assessment showed impaired upper limb motor function in 7/22 people with TIA patients and upper limb sensory impairment in 4/22 individuals. Cognitive tasks involving robotic assessment of the upper limb were completed in 13 participants, of whom 8 (61.5% showed significant impairment. Abnormal performance in the CMSA arm inventory was present in 12/22 (54.5% participants. ARWMC was 11.8 ± 6.4 and CMI was 5.4 ± 1.5. DWI was positive in 0 participants. Quantitative robotic assessment showed that people who have had a TIA display a spectrum of upper limb motor and sensory performance deficits as well as cognitive function deficits despite resolution of symptoms and no evidence of tissue infarction.

  3. Robotic exoskeleton assessment of transient ischemic attack.

    Science.gov (United States)

    Simmatis, Leif; Krett, Jonathan; Scott, Stephen H; Jin, Albert Y

    2017-01-01

    We used a robotic exoskeleton to quantify specific patterns of abnormal upper limb motor behaviour in people who have had transient ischemic attack (TIA). A cohort of people with TIA was recruited within two weeks of symptom onset. All individuals completed a robotic-based assessment of 8 behavioural tasks related to upper limb motor and proprioceptive function, as well as cognitive function. Robotic task performance was compared to a large cohort of controls without neurological impairments corrected for the influence of age. Impairment in people with TIA was defined as performance below the 5th percentile of controls. Participants with TIA were also assessed with the National Institutes of Health Stroke Scale (NIHSS) score, Chedoke-McMaster Stroke Assessment (CMSA) of the arm, the Behavioural Inattention Test (BIT), the Purdue pegboard test (PPB), and the Montreal Cognitive Assessment (MoCA). Age-related white matter change (ARWMC), prior infarction and cella-media index (CMI) were assessed from baseline CT scan that was performed within 24 hours of TIA. Acute infarction was assessed from diffusion-weighted imaging in a subset of people with TIA. Twenty-two people with TIA were assessed. Robotic assessment showed impaired upper limb motor function in 7/22 people with TIA patients and upper limb sensory impairment in 4/22 individuals. Cognitive tasks involving robotic assessment of the upper limb were completed in 13 participants, of whom 8 (61.5%) showed significant impairment. Abnormal performance in the CMSA arm inventory was present in 12/22 (54.5%) participants. ARWMC was 11.8 ± 6.4 and CMI was 5.4 ± 1.5. DWI was positive in 0 participants. Quantitative robotic assessment showed that people who have had a TIA display a spectrum of upper limb motor and sensory performance deficits as well as cognitive function deficits despite resolution of symptoms and no evidence of tissue infarction.

  4. Advanced hybrid transient stability and EMT simulation for VSC-HVDC systems

    NARCIS (Netherlands)

    Van Der Meer, A.A.; Gibescu, M.; Van Der Meijden, M.A.M.M.; Kling, W.L.; Ferreira, J.A.

    2015-01-01

    This paper deals with advanced hybrid transient stability and electromagnetic-transient (EMT) simulation of combined ac/dc power systems containing large amounts of renewable energy sources interfaced through voltage-source converter-high-voltage direct current (VSC-HVDC). The concerning transient

  5. Transient Stability Improvement of IEEE 9 Bus System Using Power World Simulator

    Directory of Open Access Journals (Sweden)

    Kaur Ramandeep

    2016-01-01

    Full Text Available The improvement of transient stability of power system was one of the most challenging research areas in power engineer.The main aim of this paper was transient stability analysis and improvement of IEEE 9 bus system. These studies were computed using POWER WORLD SIMULATOR. The IEEE 9 bus system was modelled in power world simulator and load flow studies were performed to determine pre-fault conditions in the system using Newton-Raphson method. The transient stability analysis was carried out using Runga method during three-phase balanced fault. For the improvement transient stability, the general methods adopted were fast acting exciters, FACT devices and addition of parallel transmission line. These techniques play an important role in improving the transient stability, increasing transmission capacity and damping low frequency oscillations.

  6. Analysis and estimation of transient stability for a grid-connected wind turbine with induction generator

    DEFF Research Database (Denmark)

    Li, H.; Zhao, B.; Yang, C.

    2011-01-01

    based on normal form theory is proposed. The transient models of the wind turbine generation system including the flexible drive train model are derived based on the direct transient stability estimation method. A method of critical clearing time (CCT) calculation is developed for the transient......Increasing levels of wind energy in modern electrical power system is initiating a need for accurate analysis and estimation of transient stability of wind turbine generation systems. This paper investigates the transient behaviors and possible direct methods for transient stability evaluation...... of a grid-connected wind turbine with squirrel cage induction generator (SCIG). Firstly, by using an equivalent lump mass method, a three-mass wind turbine equivalent model is proposed considering both the blades and the shaft flexibility of the wind turbine drive train system. Combined with the detailed...

  7. A hybrid superconducting fault current limiter for enhancing transient stability in Korean power systems

    Science.gov (United States)

    Seo, Sangsoo; Kim, Seog-Joo; Moon, Young-Hwan; Lee, Byongjun

    2013-11-01

    Additional power generation sites have been limited in Korea, despite the fact load demands are gradually increasing. In order to meet these increasing demands, Korea’s power system company has begun constructing new generators at existing sites. Thus, multi-unit plants can create problems in terms of transient stability when a large disturbance occurs. This paper proposes a hybrid superconducting fault current limiter (SFCL) application to enhance the transient stability of multi-unit power plants. SFCLs reduce fault currents, and limitation currents decrease the imbalance of the mechanical and electrical torque of the generators, resulting in an improvement in transient stability.

  8. Transient stability analysis with equal-area criterion for out of step ...

    African Journals Online (AJOL)

    user

    *Corresponding Author: e-mail: almoatazabdelaziz@hotmail.com, Tel. ...... Transient stability of power systems: theory and Practice, John Wiley and Sons. ... and protection and new optimization techniques in power systems operation and.

  9. Improvement of the transient stability using SFCL in Korean power systems

    International Nuclear Information System (INIS)

    Hwang, Intae; Lee, Seung Ryul; Seo, Sangsoo; Yoon, Jaeyoung; Kim, Chul-Hwan

    2013-01-01

    Highlights: •In Korea, the Special Protection System is applied for protecting the power system. •Hybrid SFCL is protecting the power system from viewpoint of the transient stability. •Basic hybrid SFCL system cannot recover during the auto-reclosing operation. •This paper performs analysis of transient stability using the novel hybrid SFCL. -- Abstract: This paper proposed a novel hybrid SFCL system for the enhancement of the transient stability in Korean power transmission system with auto-reclosing operation. The proposed SFCL system has an operation mechanism that the current limiting impedance is eliminated from the power system in a fault clearing time for the enhancement of the transient stability. Also, the system can cover the auto-reclosing operation of the transmission power system. This study analyzed an improvement of the special protection system by applying the proposed SFCL system to real power system in Korea

  10. Transient stability enhancement of modern power grid using predictive Wide-Area Monitoring and Control

    Science.gov (United States)

    Yousefian, Reza

    This dissertation presents a real-time Wide-Area Control (WAC) designed based on artificial intelligence for large scale modern power systems transient stability enhancement. The WAC using the measurements available from Phasor Measurement Units (PMUs) at generator buses, monitors the global oscillations in the system and optimally augments the local excitation system of the synchronous generators. The complexity of the power system stability problem along with uncertainties and nonlinearities makes the conventional modeling non-practical or inaccurate. In this work Reinforcement Learning (RL) algorithm on the benchmark of Neural Networks (NNs) is used to map the nonlinearities of the system in real-time. This method different from both the centralized and the decentralized control schemes, employs a number of semi-autonomous agents to collaborate with each other to perform optimal control theory well-suited for WAC applications. Also, to handle the delays in Wide-Area Monitoring (WAM) and adapt the RL toward the robust control design, Temporal Difference (TD) is proposed as a solver for RL problem or optimal cost function. However, the main drawback of such WAC design is that it is challenging to determine if an offline trained network is valid to assess the stability of the power system once the system is evolved to a different operating state or network topology. In order to address the generality issue of NNs, a value priority scheme is proposed in this work to design a hybrid linear and nonlinear controllers. The algorithm so-called supervised RL is based on mixture of experts, where it is initialized by linear controller and as the performance and identification of the RL controller improves in real-time switches to the other controller. This work also focuses on transient stability and develops Lyapunov energy functions for synchronous generators to monitor the stability stress of the system. Using such energies as a cost function guarantees the convergence

  11. Impacts of P-f & Q-V Droop Control on MicroGrids Transient Stability

    Science.gov (United States)

    Zhao-xia, Xiao; Hong-wei, Fang

    Impacts of P-f & Q-V droop control on MicroGrid transient stability was investigated with a wind unit of asynchronous generator in the MicroGrid. The system frequency stability was explored when the motor load starts and its load power changes, and faults of different types and different locations occurs. The simulations were done by PSCAD/EMTDC.

  12. Transient stability probability evaluation of power system incorporating with wind farm and SMES

    DEFF Research Database (Denmark)

    Fang, Jiakun; Miao, Lu; Wen, Jinyu

    2013-01-01

    Large scale renewable power generation brings great challenges to the power system operation and stabilization. Energy storage is one of the most important technologies to face the challenges. This paper proposes a method for transient stability probability evaluation of power system with wind farm...... and SMES. Firstly, a modified 11-bus test system with both wind farm and SMES has been implemented. The wind farm is represented as a doubly fed induction generator (DFIG). Then a stochastic-based approach to evaluate the probabilistic transient stability index of the power system is presented. Uncertain...... the probability indices. With the proposed method based on Monte-Carlo simulation and bisection method, system stability is "measured". Quantitative relationship of penetration level, SMES coil size and system stability is established. Considering the stability versus coil size to be the production curve...

  13. HYTRAN: hydraulic transient code for investigating channel flow stability

    International Nuclear Information System (INIS)

    Kao, H.S.; Cardwell, W.R.; Morgan, C.D.

    1976-01-01

    HYTRAN is an analytical program used to investigate the possibility of hydraulic oscillations occurring in a reactor flow channel. The single channel studied is ordinarily the hot channel in the reactor core, which is parallel to other channels and is assumed to share a constant pressure drop with other channels. Since the channel of highest thermal state is studied, provision is made for two-phase flow that can cause a flow instability in the channel. HYTRAN uses the CHATA(1) program to establish a steady-state condition. A heat flux perturbation is then imposed on the channel, and the flow transient is calculated as a function of time

  14. Impact of Load Behavior on Transient Stability and Power Transfer Limitations

    DEFF Research Database (Denmark)

    Gordon, Mark

    2009-01-01

    This paper presents utility based load modeling practices and explores the interaction between loads and the power system and the effect of the interaction on transient stability and power transfer limitations. The effect of load composition is investigated at major load centers together with the......This paper presents utility based load modeling practices and explores the interaction between loads and the power system and the effect of the interaction on transient stability and power transfer limitations. The effect of load composition is investigated at major load centers together...... with the impact on rotor angle excursions of large scale generators during the transient and post-transient period. Responses of multi-induction motor stalling are also considered for different fault clearances in the system. Findings of the investigations carried out on the Eastern Australian interconnected...

  15. Application of a combined superconducting fault current limiter and STATCOM to enhancement of power system transient stability

    Energy Technology Data Exchange (ETDEWEB)

    Mahdad, Belkacem, E-mail: bemahdad@mselab.org; Srairi, K.

    2013-12-15

    Highlights: •A simple interactive model SFCL–STATCOM Controller is proposed to enhance the transient stability. •The STATCOM controller is integrated in coordination with the SFCL to support the excessive reactive power during fault. •Voltage stability index based continuation power flow is used to locate the STATCOM and the SFCL. •The clearing time improved compared to other cases (with only SFCL, with only STATCOM). •The choice of the STATCOM parameters is very important to exploit efficiently the integration of STATCOM Controller. -- Abstract: Stable and reliable operation of the power system network is dependent on the dynamic equilibrium between energy production and power demand under large disturbance such as short circuit or important line tripping. This paper investigates the use of combined model based superconducting fault current limiter (SFCL) and shunt FACTS Controller (STATCOM) for assessing the transient stability of a power system considering the automatic voltage regulator. The combined model located at a specified branch based on voltage stability index using continuation power flow. The main role of the proposed combined model is to achieve simultaneously a flexible control of reactive power using STATCOM Controller and to reduce fault current using superconducting technology based SFCL. The proposed combined model has been successfully adapted within the transient stability program and applied to enhance the transient power system stability of the WSCC9-Bus system. Critical clearing time (CCT) has been used as an index to evaluate and validate the contribution of the proposed coordinated Controller. Simulation results confirm the effectiveness and perspective of this combined Controller to enhance the dynamic power system performances.

  16. Modelling and transient stability of large wind farms

    DEFF Research Database (Denmark)

    Akhmatov, Vladislav; Knudsen, Hans; Nielsen, Arne Hejde

    2003-01-01

    by a physical model of grid-connected windmills. The windmill generators ate conventional induction generators and the wind farm is ac-connected to the power system. Improvements-of short-term voltage stability in case of failure events in the external power system are treated with use of conventional generator...... technology. This subject is treated as a parameter study with respect to the windmill electrical and mechanical parameters and with use of control strategies within the conventional generator technology. Stability improvements on the wind farm side of the connection point lead to significant reduction...

  17. Power System Transient Stability Improvement Using Demand Side Management in Competitive Electricity Markets

    DEFF Research Database (Denmark)

    Hu, Weihao; Wang, Chunqi; Chen, Zhe

    2012-01-01

    Since the hourly spot market price is available one day ahead in Denmark, the price could be transferred to the consumers and they may shift some of their loads from high price periods to the low price periods in order to save their energy costs. The optimal load response to an electricity price...... for demand side management generates different load profiles and may provide an opportunity to improve the transient stability of power systems with high wind power penetrations. In this paper, the idea of the power system transient stability improvement by using optimal load response to the electricity...... price is proposed. A 102-bus power system which represents a simplified model of the western Danish power system is chosen as the study case. Simulation results show that the optimal load response to electricity prices is an effective measure to improve the power system transient stability with high...

  18. Morocco; Financial System Stability Assessment

    OpenAIRE

    International Monetary Fund

    2003-01-01

    The Financial System Stability Assessment of Morocco reviews the reform program that is aimed at establishing a modern, market-oriented financial system that optimizes the mobilization of savings and the allocation of financial resources. It reviews the modernization of the banking sector and the development of competition within the sector, development of financial markets, and removal of constraints on financial system activity. It also provides reports on the Observance of Standards and Co...

  19. Nigeria; Financial Sector Stability Assessment

    OpenAIRE

    International Monetary Fund

    2013-01-01

    This Financial Sector Stability Assessment on Nigeria discusses the macroeconomic performance and structure of the financial system. Although Nigerian economy experienced both domestic and external shocks in recent years, the economy continued to grow rapidly, achieving more than 7 percent growth each year since 2009. The performance of financial institutions has begun to improve, though some of the emergency anti-crisis measures continue to be in place. However, the regulatory and supervisor...

  20. Canada; Financial Sector Stability Assessment

    OpenAIRE

    International Monetary Fund

    2014-01-01

    This report discusses key findings of the Financial Sector Stability Assessment on Canada. Canada’s financial system successfully navigated the global financial crisis, and stress tests suggest that major financial institutions would continue to be resilient to credit, liquidity, and contagion risks arising from a severe stress scenario. Elevated housing prices and high household debt remain an area of concern, though targeted prudential and macroprudential measures are proving to be effectiv...

  1. Transient Stability Enhancement in Power System Using Static VAR Compensator (SVC

    Directory of Open Access Journals (Sweden)

    Youssef MOULOUDI

    2012-12-01

    Full Text Available In this paper, an indirect adaptive fuzzy excitation and static VAR (unit of reactive power, volt-ampere reactive compensator (SVC controller is proposed to enhance transient stability for the power system, which based on input-output linearization technique. A three-bus system, which contains a generator and static VAR compensator (SVC, is considered in this paper, the SVC is located at the midpoint of the transmission lines. Simulation results show that the proposed controller compared with a controller based on tradition linearization technique can enhance the transient stability of the power system under a large sudden fault, which may occur nearly at the generator bus terminal.

  2. Considerations for transient stability, fault capacity and power flow study of offsite power system

    Energy Technology Data Exchange (ETDEWEB)

    Shin, M C; Kim, C W; Gwon, M H; Park, C W; Lee, K W; Kim, H M; Lee, G Y; Joe, P H [Sungkyunkwan Univ., Seoul (Korea, Republic of)

    1994-04-15

    By study of power flow calculation, fault capacity calculation and stability analysis according to connection of two units YGN 3 and 4 to KEPCO power system, we have conclusions as follows. As the result of power flow calculation, at peak load, the voltage change of each bus is very small when YGN 3 and 4 is connected with KEPCO power system. At base load, installation of phase modifing equipment is necessary in Seoul, Kyungki province where load is concentrated because bus voltage rises by increasing of charge capacity caused installation of underground cables. As the result of fault capacity calculation, fault capacity is increased because fault current increases when two units YGN 3 and 4 is connected with KEPCO power system. But it is enough to operate with presenting circuits breaker rated capacity. Transient stability studies have been conducted on the YK N/P generators 3 and 4 using a digital computer program. Three phase short faults have been simulated at the YK N/P 345[KV] bus with the resulting outage of transmission circuits. Several fault clearing times are applied: 6 cycles, 12 cycles, 15 cycles. The study results demonstrate that the transient stability of YK N/P is adequate to maintain stable for three phase short faults cleared within 12 cycles. The study results also demonstrate that the transient stability of YK N/P is stable for machine removals except 4-machine removal. In addition, the study shows that the transient stability analysis is implemented for the case of load.

  3. Influencing Power Flow and Transient Stability by Static Synchronous Series Compensator

    Directory of Open Access Journals (Sweden)

    Md. Imran Azim

    2015-04-01

    Full Text Available In the present world, modern power system networks, being a complicated combination of generators, transmission lines, transformers, circuit breakers and other devices, are more vulnerable to various types of faults causing stability problems. Among these faults, transient fault is believed to be a major disturbance as it causes large damage to a sound system within a certain period of time. Therefore, the protection against transient faults, better known as transient stability control is one of the major considerations for the power system engineers. This paper presents the control approach in the transmission line during transient faults by means of Static Synchronous Series Compensator (SSSC in order to stabilize Single Machine Infinite Bus (SMIB system.  In this paper, SSSC is represented by variable voltage injection associated with the transformer leakage reactance and the voltage source. The comparative results depict that the swing curve of a system increases monotonically after the occurrence of transient faults However, SSSC is effective enough to make it stable after a while.

  4. Transient stability improvement by nonlinear controllers based on tracking

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, Juan M. [Centro de Investigacion y Estudios Avanzados, Guadalajara, Mexico. Av. Cientifica 1145. Col. El Bajio. Zapopan, Jal. 45015 (Mexico); Arroyave, Felipe Valencia; Correa Gutierrez, Rosa Elvira [Universidad Nacional de Colombia, Sede Medellin. Facultad de Minas, Escuela de Mecatronica (Colombia)

    2011-02-15

    This paper deals with the control problem in multi-machine electric power systems, which represent complex great scale nonlinear systems. Thus, the controller design is a challenging problem. These systems are subjected to different perturbations, such as short circuits, connection and/or disconnection of loads, lines, or generators. Then, the utilization of controllers which guarantee good performance under those perturbations is required in order to provide electrical energy to the loads with admissible stability margins. The proposed controllers are based on a systematic strategy, which calculate nonlinear controllers for generating units in a power plant, both for voltage and velocity regulation. The formulation allows designing controllers in a multi-machine power system without intricate calculations. Results on a power system of the open research indicate the proposition's suitability. The problem is formulated as a tracking problem. The designed controllers may be implemented in any electric power system. (author)

  5. Transient Voltage Stability Analysis and Improvement of A Network with different HVDC Systems

    DEFF Research Database (Denmark)

    Liu, Yan; Chen, Zhe

    2011-01-01

    This paper presents transient voltage stability analysis of an AC system with multi-infeed HVDC links including a traditional LCC HVDC link and a VSC HVDC link. It is found that the voltage supporting capability of the VSC-HVDC link is significantly influenced by the tie-line distance between the...

  6. Study on transient stability of wind turbine with induction generator based on variable pitch control strategy

    DEFF Research Database (Denmark)

    Zhao, B.; Li, H.; Han, L.

    2011-01-01

    In order to enhance and improve the transient stability of a grid-connected wind turbine generator system under the power grid fault, based on typical pitch control strategy of wind turbine, considering the wind turbine system oscillation caused by the drive-train shaft flexibility, Based on Matl...

  7. Transient Stability Improvement for Combined Heat and Power System Using Load Shedding

    Directory of Open Access Journals (Sweden)

    Hung-Cheng Chen

    2014-01-01

    Full Text Available The purpose of the paper is to analyze and improve the transient stability of an industrial combined heat and power (CHP system in a high-tech science park in Taiwan. The CHP system installed two 161 kV/161 kV high-impendence transformers to connect with Taipower System (TPS for both decreasing the short-circuit fault current and increasing the fault critical clearing time. The transient stabilities of three types of operation modes in CHP units, 3G1S, 2G1S, and 1G1S, are analyzed. Under the 3G1S operation mode, the system frequency is immediately restored to 60 Hz after tie line tripping with the TPS. Under the 1G1S and 2G1S operation modes, the system frequencies will continuously decrease and eventually become unstable. A novel transient stability improvement approach using load shedding technique based on the change in frequency is proposed to improve the transient stability.

  8. Transient Angle Stability Analysis of Grid-Connected Converters with the First-order Active Power Loop

    DEFF Research Database (Denmark)

    Wu, Heng; Wang, Xiongfei

    2018-01-01

    . To tackle this challenge, this paper employs the phase portrait to analyze the transient stability of power converters, and it is found that the better transient stability performance can be achieved if the grid-connected converters are controlled as the first-order nonlinear system. Simulations...

  9. Consequence and impact of electric utility industry restructuring on transient stability and small-signal stability analysis

    International Nuclear Information System (INIS)

    Vittal, V.

    2000-01-01

    The electric utility industry is undergoing unprecedented changes in its structure worldwide. With the advent of an open market environment and competition in the industry, and restructuring of the industry into separate generation, transmission, and distribution entities, new issues in power system operation and planning are inevitable. One of the major consequences of this new electric utility environment is the greater emphasis on reliability and secure operation of the power system. This paper examines the impact of restructuring on power system dynamic analysis. It specifically addresses issues related to transient stability analysis and small-signal stability analysis. Four major topics to examine the effect on the nature of studies conducted are considered. These topics are (1) system adequacy and security, (2) system modeling data requirements, (3) system protection and control, and (4) system restoration. The consequences and impact of each of these topics on the nature of the studies conducted are examined and discussed. The emphasis on greater reliability has led to a clearer enunciation of standards, measurements, and guides in some countries. These requirements will result in: (1) more measurements on existing systems, (2) rigorous analysis of transient stability and small-signal stability to determine operating limits and plan systems, (3) greater emphasis on studies to verify coordination and proper performance of protection and controls, and (4) development of a detailed plan for system restoration in the case of wide-spread outages

  10. Simplified distributed parameters BWR dynamic model for transient and stability analysis

    International Nuclear Information System (INIS)

    Espinosa-Paredes, Gilberto; Nunez-Carrera, Alejandro; Vazquez-Rodriguez, Alejandro

    2006-01-01

    This paper describes a simplified model to perform transient and linear stability analysis for a typical boiling water reactor (BWR). The simplified transient model was based in lumped and distributed parameters approximations, which includes vessel dome and the downcomer, recirculation loops, neutron process, fuel pin temperature distribution, lower and upper plenums reactor core and pressure and level controls. The stability was determined by studying the linearized versions of the equations representing the BWR system in the frequency domain. Numerical examples are used to illustrate the wide application of the simplified BWR model. We concluded that this simplified model describes properly the dynamic of a BWR and can be used for safety analysis or as a first approach in the design of an advanced BWR

  11. Optimized Extreme Learning Machine for Power System Transient Stability Prediction Using Synchrophasors

    Directory of Open Access Journals (Sweden)

    Yanjun Zhang

    2015-01-01

    Full Text Available A new optimized extreme learning machine- (ELM- based method for power system transient stability prediction (TSP using synchrophasors is presented in this paper. First, the input features symbolizing the transient stability of power systems are extracted from synchronized measurements. Then, an ELM classifier is employed to build the TSP model. And finally, the optimal parameters of the model are optimized by using the improved particle swarm optimization (IPSO algorithm. The novelty of the proposal is in the fact that it improves the prediction performance of the ELM-based TSP model by using IPSO to optimize the parameters of the model with synchrophasors. And finally, based on the test results on both IEEE 39-bus system and a large-scale real power system, the correctness and validity of the presented approach are verified.

  12. An improved direct feedback linearization technique for transient stability enhancement and voltage regulation of power generators

    Energy Technology Data Exchange (ETDEWEB)

    Kenne, Godpromesse [Laboratoire d' Automatique et d' Informatique Appliquee (LAIA), Departement de Genie Electrique, Universite de Dschang, B.P. 134 Bandjoun, Cameroun; Goma, Raphael; Lamnabhi-Lagarrigue, Francoise [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Nkwawo, Homere [Departement GEII, Universite Paris XIII, IUT Villetaneuse, 99 Avenue Jean Baptiste Clement, 93430 Villetaneuse (France); Arzande, Amir; Vannier, Jean Claude [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France)

    2010-09-15

    In this paper, a simple improved direct feedback linearization design method for transient stability and voltage regulation of power systems is discussed. Starting with the classical direct feedback linearization technique currently applied to power systems, an adaptive nonlinear excitation control of synchronous generators is proposed, which is new and effective for engineering. The power angle and mechanical power input are not assumed to be available. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of angular speed, active electric power and generator terminal voltage. Experimental results of a practical power system show that fast response, robustness, damping, steady-state and transient stability as well as voltage regulation are all achieved satisfactorily. (author)

  13. Improvement of Transient Stability of Power System by System Damping Series Resistor (SDSR)

    OpenAIRE

    上里, 勝実; 千住, 智信; 当銘, 秀之; 高原, 景滋; Uezato, Katsumi; Senjyu, Tomonobu; Toume, Hideyuki; Takahara, Keiji

    1990-01-01

    The system damping resistor is one of the method for improving the transient stability of power systems. The main circuit is the simple construction so that is low cost and is few abnormal surge, and is superior in ability of economy, reliability and maintenance. Conventionally, most of all system damping resistors have adopted the paralleled resistor, whereas the series resistor is used little.In this paper, we investigate the characteristics of the series resistor by comparing with the para...

  14. Quantification and analysis of color stability based on thermal transient behavior in white LED lamps.

    Science.gov (United States)

    Nisa Khan, M

    2017-09-20

    We present measurement and analysis of color stability over time for two categories of white LED lamps based on their thermal management scheme, which also affects their transient lumen depreciation. We previously reported that lumen depreciation in LED lamps can be minimized by properly designing the heat sink configuration that allows lamps to reach a thermal equilibrium condition quickly. Although it is well known that lumen depreciation degrades color stability of white light since color coordinates vary with total lumen power by definition, quantification and characterization of color shifts based on thermal transient behavior have not been previously reported in literature for LED lamps. Here we provide experimental data and analysis of transient color shifts for two categories of household LED lamps (from a total of six lamps in two categories) and demonstrate that reaching thermal equilibrium more quickly provides better stability for color rendering, color temperature, and less deviation of color coordinates from the Planckian blackbody locus line, which are all very important characterization parameters of color for white light. We report for the first time that a lamp's color degradation from the turn-on time primarily depends on thermal transient behavior of the semiconductor LED chip, which experiences a wavelength shift as well as a decrease in its dominant wavelength peak value with time, which in turn degrades the phosphor conversion. For the first time, we also provide a comprehensive quantitative analysis that differentiates color degradation due to the heat rise in GaN/GaInN LED chips and subsequently the boards these chips are mounted on-from that caused by phosphor heating in a white LED module. Finally, we briefly discuss why there are some inevitable trade-offs between omnidirectionality and color and luminous output stability in current household LED lamps and what will help eliminate these trade-offs in future lamp designs.

  15. A new strategy for transient stability using augmented generator control and local dynamic braking

    Energy Technology Data Exchange (ETDEWEB)

    Dorsey, J; Jiang, H; Habetler, T [Georgia Inst. of Tech., Atlanta, GA (United States); Qu, Z [University of Central Florida, Orlando, FL (United States)

    1994-12-31

    A decentralized automatic control strategy for significantly improving the transient stability of a large power system is introduced. The strategy combines local dynamic braking and a straightforward augmentation of the existing turbine / governor control system that uses only local feedback. The brake resistor, which employs thick film, metal oxide technology, has no inductance and is of very low resistance, allowing its use during fault to show a generator`s acceleration. Simulation results using the 39 Bus New England system show that the strategy dramatically increases the global stability of a power system. (author) 15 refs., 7 figs., 1 tab.

  16. Calculation and Simulation Study on Transient Stability of Power System Based on Matlab/Simulink

    Directory of Open Access Journals (Sweden)

    Shi Xiu Feng

    2016-01-01

    Full Text Available The stability of the power system is destroyed, will cause a large number of users power outage, even cause the collapse of the whole system, extremely serious consequences. Based on the analysis in single machine infinite system as an example, when at the f point two phase ground fault occurs, the fault lines on either side of the circuit breaker tripping resection at the same time,respectively by two kinds of calculation and simulation methods of system transient stability analysis, the conclusion are consistent. and the simulation analysis is superior to calculation analysis.

  17. Impact of PSS and SVC on the Power System Transient Stability

    Directory of Open Access Journals (Sweden)

    Mohammed Omar Benaissa

    2017-06-01

    Full Text Available The Static Var Compensator (SVC is used to improve the stability of the power system because of its role in injecting or absorbing the reactive power in the electrical transmission lines. The Power System Stabilizer (PSS is also a control device which ensures maximum power transfer and thus the stability of the power system enhancement. The PSS has been widely used to damp electromechanical oscillations occur in power systems. If no adequate damping is available, the oscillations will increase leading to instability. The present work is an original contribution to the problem of transient stability in the electrical power system, the authors have made some efforts to illustrate the flexibility and the importance of inserting the SVC alone or with the PSS the fact that maintain the characteristics of the system within acceptable limits in a very short time. The results show that the system has been developed successfully in terms of transient stability in a bi-machine transmission system only with the presence of PSS when a single-phase fault has been occurred, while the presence of SVC is more than essential when a three-phase fault is occurred.

  18. Stability of one-step methods in transient nonlinear heat conduction

    International Nuclear Information System (INIS)

    Hughes, J.R.

    1977-01-01

    The purpose of the present work is to ascertain practical stability conditions for one-step methods commonly used in transient nonlinear heat conduction analyses. In this paper the concepts of stability, appropriate to the nonlinear problem, are thoroughly discussed. They of course reduce to the usual stability critierion for the linear, constant coefficient case. However, for nonlinear problems there are differences and theses ideas are of key importance in obtaining practical stability conditions. Of particular importance is a recent result which indicates that, in a sense, the trapezoidal and midpoint families are equivalent. Thus, stability results for one family may be translated into a result for the other. The main results obtained are: The stability behaviour of the explicit Euler method in the nonlinear regime is analogous to that for linear problems. In particular, an a priori step size restriction may be determined for each time step. The precise time step restriction on implicit conditionally stable members of the trapezoidal and midpoint families is shown not to be determinable a priori. Of considerable practical significance, unconditionally stable members of the trapezoidal and midpoint families are identified. All notions of stability employed are motivated and defined, and their interpretations in practical computing are indicated. (Auth.)

  19. Stability of one-step methods in transient nonlinear heat conduction

    International Nuclear Information System (INIS)

    Hughes, J.R.

    1977-01-01

    The purpose of the present work is to ascertain practical stability conditions for one-step methods commonly used in transient nonlinear heat conduction analyses. The class of problems considered is governed by a temporally continuous, spatially discrete system involving the capacity matrix C, conductivity matrix K, heat supply vector, temperature vector and time differenciation. In the linear case, in which K and C are constant, the stability behavior of one-step methods is well known. But in this paper the concepts of stability, appropriate to the nonlinear problem, are thoroughly discussed. They of course reduce to the usual stability criterion for the linear, constant coefficient case. However, for nonlinear problems there are differences and these ideas are of key importance in obtaining practical stability conditions. Of particular importance is a recent result which indicates that, in a sense, the trapezoidal and midpoint families are quivalent. Thus, stability results for one family may be translated into a result for the other. The main results obtained are summarized as follows. The stability behavior of the explicit Euler method in the nonlinear regime is analogous to that for linear problems. In particular, an a priori step size restriction may be determined for each time step. The precise time step restriction on implicit conditionally stable members of the trapezoidal and midpoint families is shown not to be determinable a priori. Of considerable practical significance, unconditionally stable members of the trapezoidal and midpoint families are identified

  20. Simulation for transient stability study of the Taiwan power system - a nuclear majority system

    International Nuclear Information System (INIS)

    Huang, J.C.C.

    1984-01-01

    A transient stability program was developed for the Taiwan Power Company, which has a high proportion of nuclear generation in its power system. This program offers a new territory to investigate nuclear plant effects on the power system transient stability. This program also provides a high speed tool for the Taipower system operational planning. A generalized procedure of synchronous machine modeling for a large-scale stability study is presented. The merits and weaknesses of machine modeling can be comprehended through each item of this procedure. Three types of nonlinear synchronous machine modeling implemented into this stability program are derived by following this procedure. A robust subroutine was derived to perform the fourth order Runge-Kutta integration method, making the software programming neat and systematical. For simulating the nuclear plant influence on the system, this program implemented an additional four functions: load-limit operation simulated by a low-value gate in the governor model, bypass valve capacity monitored by sending out a warning message, rotor overspeed protection relay, and generator anti-motoring relay

  1. Western Wind and Solar Integration Study Phase 3 – Frequency Response and Transient Stability

    Energy Technology Data Exchange (ETDEWEB)

    Miller, N. W. [GE Energy Management, Schenectady, NY (United States); Shao, M. [GE Energy Management, Schenectady, NY (United States); Pajic, S. [GE Energy Management, Schenectady, NY (United States); D' Aquila, R. [GE Energy Management, Schenectady, NY (United States)

    2014-12-01

    Power system operators and utilities worldwide have concerns about the impact of high-penetration wind and solar generation on electric grid reliability (EirGrid 2011b, Hydro-Quebec 2006, ERCOT 2010). The stability of North American grids under these conditions is a particular concern and possible impediment to reaching future renewable energy goals. Phase 3 of the Western Wind and Solar Integration Study (WWSIS-3) considers a 33% wind and solar annual energy penetration level that results in substantial changes to the characteristics of the bulk power system, including different power flow patterns, different commitment and dispatch of existing synchronous generation, and different dynamic behavior of wind and solar generation. WWSIS-3 evaluates two specific aspects of fundamental frequency system stability: frequency response and transient stability.

  2. A Comparative Study on Controllers for Improving Transient Stability of DFIG Wind Turbines During Large Disturbances

    Directory of Open Access Journals (Sweden)

    Minh Quan Duong

    2018-02-01

    Full Text Available Under power system short-circuits, the Doubly-Fed Induction Generator (DFIG Wind Turbines (WT are required to be equipped with crowbar protections to preserve the lifetime of power electronics devices. When the crowbar is switched on, the rotor windings are short-circuited. In this case, the DFIG behaves like a squirrel-cage induction generator (SCIG and can adsorb reactive power, which can affect the power system. A DFIG based-fault-ride through (FRT scheme with crowbar, rotor-side and grid-side converters has recently been proposed for improving the transient stability: in particular, a hybrid cascade Fuzzy-PI-based controlling technique has been demonstrated to be able to control the Insulated Gate Bipolar Transistor (IGBT based frequency converter in order to enhance the transient stability. The performance of this hybrid control scheme is analyzed here and compared to other techniques, under a three-phase fault condition on a single machine connected to the grid. In particular, the transient operation of the system is investigated by comparing the performance of the hybrid system with conventional proportional-integral and fuzzy logic controller, respectively. The system validation is carried out in Simulink, confirming the effectiveness of the coordinated advanced fuzzy logic control.

  3. Segregated copper ratio experiment on transient stability (SeCRETS). Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzone, P. [ed.] [Ecole Polytechnique Federale de Lausanne, Centre de Recherches en Physique des Plasmas (CRPP), CH-1015 Lausanne (Switzerland)

    2001-01-01

    Two Nb{sub 3}Sn, steel jacketed, cable-in-conduit conductors have been manufactured with identical non-Cu cross sections and the stabilizer either included in the Nb{sub 3}Sn composite or partly segregated as copper wires. The two conductors are series connected and wound as a bifilar , single layer solenoid, assembled in the high field bore (11 T) of the SULTAN test facility. The operating current is up to 12 kA (400 A/mm{sup 2}). A transverse pulsed field is applied with {delta}B up to 2.7 T, field rate up to 180 T/s and field integral up to 530 T{sup 2}/s. In the dc test, a good agreement is found between the I{sub c} and the T{sub cs} results, both correctly scaling according to the parameters derived from the strand tests. The n-value from the V-I curve is in the range of 15. The current sharing at the high field section is correlated with a local current re-distribution, observed by arrays of miniature Hall sensors, detecting the self-field around the conductor. The ac losses results in the range of 2 to 9 Hz by gas flow calorimetry indicate coupling currents constant, n{tau}, in the range of 1.5 ms at high field, increasing by a factor of 2 with 12 kA transport current. Loss extrapolation to 0 frequency suggests that the loss curve may be not linear outside the test range, with higher n{tau} at lower field rate. The calorimetric loss estimation at the fast field transient (f=15 Hz) indicates n{tau} {approx_equal} 2 ms. The ITER plasma disruption transients have been reproduced by the pulsed coils. Due to the very low ac losses, no quench could be generated in either conductor even reducing the temperature margin below 0.2-0.3 K. Very large field transients, with integral above 100 T{sup 2}/s, are required to quench the conductors. In that range, the conductor without segregated copper has superior performance. Due to the large interstrand resistance (very low ac losses), the segregated copper has marginal contribution to the stability. No evidence of current

  4. Impact of Penetration Wind Turbines on Transient Stability in Sulbagsel Electrical Interconnection System

    Science.gov (United States)

    Nurtrimarini Karim, Andi; Mawar Said, Sri; Chaerah Gunadin, Indar; Darusman B, Mustadir

    2018-03-01

    This paper presents a rotor angle analysis when transient disturbance occurs when wind turbines enter the southern Sulawesi electrical interconnection system (Sulbagsel) both without and with the addition of a Power Stabilizer (PSS) control device. Time domain simulation (TDS) method is used to analyze the rotor angle deviation (δ) and rotor angle velocity (ω). A total of 44 buses, 47 lines, 6 transformers, 15 generators and 34 loads were modeled for analysis after the inclusion of large-scale wind turbines in the Sidrap and Jeneponto areas. The simulation and computation results show the addition of PSS devices to the system when transient disturbance occurs when the winds turbine entering the Sulbagsel electrical system is able to dampen and improve the rotor angle deviation (δ) and the rotor angle velocity (ω) towards better thus helping the system to continue operation at a new equilibrium point.

  5. Segregated copper ratio experiment on transient stability (SeCRETS). Final Report

    International Nuclear Information System (INIS)

    Bruzzone, P.

    2001-01-01

    Two Nb 3 Sn, steel jacketed, cable-in-conduit conductors have been manufactured with identical non-Cu cross sections and the stabilizer either included in the Nb 3 Sn composite or partly segregated as copper wires. The two conductors are series connected and wound as a bifilar , single layer solenoid, assembled in the high field bore (11 T) of the SULTAN test facility. The operating current is up to 12 kA (400 A/mm 2 ). A transverse pulsed field is applied with ΔB up to 2.7 T, field rate up to 180 T/s and field integral up to 530 T 2 /s. In the dc test, a good agreement is found between the I c and the T cs results, both correctly scaling according to the parameters derived from the strand tests. The n-value from the V-I curve is in the range of 15. The current sharing at the high field section is correlated with a local current re-distribution, observed by arrays of miniature Hall sensors, detecting the self-field around the conductor. The ac losses results in the range of 2 to 9 Hz by gas flow calorimetry indicate coupling currents constant, nτ, in the range of 1.5 ms at high field, increasing by a factor of 2 with 12 kA transport current. Loss extrapolation to 0 frequency suggests that the loss curve may be not linear outside the test range, with higher nτ at lower field rate. The calorimetric loss estimation at the fast field transient (f=15 Hz) indicates nτ ≅ 2 ms. The ITER plasma disruption transients have been reproduced by the pulsed coils. Due to the very low ac losses, no quench could be generated in either conductor even reducing the temperature margin below 0.2-0.3 K. Very large field transients, with integral above 100 T 2 /s, are required to quench the conductors. In that range, the conductor without segregated copper has superior performance. Due to the large interstrand resistance (very low ac losses), the segregated copper has marginal contribution to the stability. No evidence of current redistribution is observed during the field transients

  6. Transient improvements in fixational stability in strabismic amblyopes following bifoveal fixation and reduced interocular suppression.

    Science.gov (United States)

    Raveendran, Rajkumar Nallour; Babu, Raiju J; Hess, Robert F; Bobier, William R

    2014-03-01

    To test the hypothesis that fixational stability of the amblyopic eye in strabismics will improve when viewing provides both bifoveal fixation and reduced inter-ocular suppression by reducing the contrast to the fellow eye. Seven strabismic amblyopes (Age: 29.2 ± 9 years; five esotropes and two exotropes) showing clinical characteristics of central suppression were recruited. Interocular suppression was measured by a global motion task. For each participant, a balance point was determined which defined contrast levels for each eye where binocular combination was optimal (interocular suppression minimal). When the balance point could not be determined, this participant was excluded. Bifoveal fixation was established by ocular alignment using a haploscope. Participants dichoptically viewed similar targets (a cross of 2.3° surrounded by a square of 11.3°) at 40 cm. Target contrasts presented to each eye were either high contrast (100% to both eyes) or balanced contrast (attenuated contrast in the fellow fixing eye). Fixation stability was measured over a 5 min period and quantified using bivariate contour ellipse areas in four different binocular conditions; unaligned/high contrast, unaligned/balance point, aligned/high contrast and aligned/balance point. Fixation stability was also measured in six control subjects (Age: 25.3 ± 4 years). Bifoveal fixation in the strabismics was transient (58.15 ± 15.7 s). Accordingly, fixational stability was analysed over the first 30 s using repeated measures anova. Post hoc analysis revealed that for the amblyopic subjects, the fixational stability of the amblyopic eye was significantly improved in aligned/high contrast (p = 0.01) and aligned/balance point (p suppression. However, once initiated, bifoveal fixation is transient with the strabismic eye drifting away from foveal alignment, thereby increasing the angle of strabismus. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.

  7. Intelligent Control of UPFC for Enhancing Transient Stability on Multi-Machine Power Systems

    Directory of Open Access Journals (Sweden)

    Hassan Barati

    2010-01-01

    Full Text Available One of the benefit of FACTS devices is increase of stability in power systems with control active and reactive power at during the fault in power system. Although, the power system stabilizers (PSSs have been one of the most common controls used to damp out oscillations, this device may not produce enough damping especially to inter-area mode and therefore, there is an increasing interest in using FACTS devices to aid in damping of these oscillations. In This paper, UPFC is used for damping oscillations and to enhance the transient stability performance of power systems. The controller parameters are designed using an efficient version of the Takagi-Sugeno fuzzy control scheme. The function based Takagi-Sugeno-Kang (TSK fuzzy controller uses. For optimization parameters of fuzzy PI controller, the GA, PSO and HGAPSO algorithms are used. The computer simulation results, the effect of UPFC with conventional PI controller, fuzzy PI controller and intelligent controllers (GA, PSO and HGAPSO for damping the local-mode and inter-area mode of under large and small disturbances in the four-machine two-area power system evaluated and compared.

  8. The effect of the virtual mass force term on the stability of transient two-phase flow analysis

    International Nuclear Information System (INIS)

    Watanabe, Tadashi; Hirano, Masashi; Tanabe, Fumiya

    1989-08-01

    The effect of the virtual mass force term on the stability of transient two-phase flow analysis is studied. The objective form of the virtual mass acceleration is used. The virtual mass coefficient is determined from the stability condition of basic equations against infinitesimal high wave-number perturbations. The parameter is chosen so that a reasonable agreement between the analytical and experimental sound speed in two-phase flows can be obtained. A one-dimensional sedimentation problem is simulated by the MINCS code which is a tool for transient two-phase flow analysis. The stability analysis is performed for the numerical procedure. It is shown that calculated results are stabilized so long as the virtual mass coefficient satisfies the stability condition of differential equations. (author)

  9. Malaysia; Financial Sector Stability Assessment

    OpenAIRE

    International Monetary Fund

    2013-01-01

    This assessment is a review of the financial environment of Malaysia. Like many other Asian countries, Malaysia experienced financial distress in the late 1990s, but the country’s policy reforms have moved it to a successful economy. A ten-year financial plan (2001–10) by Bank Negara Malaysia restructured the financial sector. Banks were well capitalized, household debts were strengthened, and securities and insurances were developed. Malaysia thus became the global center for Islamic finance...

  10. Spain; Financial System Stability Assessment

    OpenAIRE

    International Monetary Fund

    2012-01-01

    This report summarizes the findings of the Financial Sector Assessment Program (FSAP) Update for Spain. Although there is a core of strong banks that are well managed and appear resilient to further shocks, vulnerabilities remain. Substantial progress has been made in reforming the former savings banks, and the most vulnerable institutions have either been resolved or are being restructured. Recent measures address the most problematic part of banks’ portfolios. Moving ahead, a further restru...

  11. Anfis Approach for Sssc Controller Design for the Improvement of Transient Stability Performance

    Science.gov (United States)

    Khuntia, Swasti R.; Panda, Sidhartha

    2011-06-01

    In this paper, Adaptive Neuro-Fuzzy Inference System (ANFIS) method based on the Artificial Neural Network (ANN) is applied to design a Static Synchronous Series Compensator (SSSC)-based controller for improvement of transient stability. The proposed ANFIS controller combines the advantages of fuzzy controller and quick response and adaptability nature of ANN. The ANFIS structures were trained using the generated database by fuzzy controller of SSSC. It is observed that the proposed SSSC controller improves greatly the voltage profile of the system under severe disturbances. The results prove that the proposed SSSC-based ANFIS controller is found to be robust to fault location and change in operating conditions. Further, the results obtained are compared with the conventional lead-lag controllers for SSSC.

  12. Non-modal stability analysis and transient growth in a magnetized Vlasov plasma

    KAUST Repository

    Ratushnaya, V.

    2014-12-01

    Collisionless plasmas, such as those encountered in tokamaks, exhibit a rich variety of instabilities. The physical origin, triggering mechanisms and fundamental understanding of many plasma instabilities, however, are still open problems. We investigate the stability properties of a 3-dimensional collisionless Vlasov plasma in a stationary homogeneous magnetic field. We narrow the scope of our investigation to the case of Maxwellian plasma and examine its evolution with an electrostatic approximation. For the first time using a fully kinetic approach we show the emergence of the local instability, a transient growth, followed by classical Landau damping in a stable magnetized plasma. We show that the linearized Vlasov operator is non-normal leading to the algebraic growth of the perturbations using non-modal stability theory. The typical time scales of the obtained instabilities are of the order of several plasma periods. The first-order distribution function and the corresponding electric field are calculated and the dependence on the magnetic field and perturbation parameters is studied. Our results offer a new scenario of the emergence and development of plasma instabilities on the kinetic scale.

  13. Improving power grid transient stability by plug-in electric vehicles

    International Nuclear Information System (INIS)

    Gajduk, Andrej; Kocarev, Ljupco; Todorovski, Mirko; Kurths, Juergen

    2014-01-01

    Plug-in electric vehicles (PEVs) can serve in discharge mode as distributed energy and power resources operating as vehicle-to-grid (V2G) devices and in charge mode as loads or grid-to-vehicle devices. It has been documented that PEVs serving as V2G systems can offer possible backup for renewable power sources, can provide reactive power support, active power regulation, load balancing, peak load shaving, can reduce utility operating costs and can generate revenue. Here we show that PEVs can even improve power grid transient stability, that is, stability when the power grid is subjected to large disturbances, including bus faults, generator and branch tripping, and sudden large load changes. A control strategy that regulates the power output of a fleet of PEVs based on the speed of generator turbines is proposed and tested on the New England 10-unit 39-bus power system. By regulating the power output of the PEVs we show that (1) speed and voltage fluctuations resulting from large disturbances can be significantly reduced up to five times, and (2) the critical clearing time can be extended by 20–40%. Overall, the PEVs control strategy makes the power grid more robust. (paper)

  14. Non-modal stability analysis and transient growth in a magnetized Vlasov plasma

    KAUST Repository

    Ratushnaya, V.; Samtaney, Ravi

    2014-01-01

    Collisionless plasmas, such as those encountered in tokamaks, exhibit a rich variety of instabilities. The physical origin, triggering mechanisms and fundamental understanding of many plasma instabilities, however, are still open problems. We investigate the stability properties of a 3-dimensional collisionless Vlasov plasma in a stationary homogeneous magnetic field. We narrow the scope of our investigation to the case of Maxwellian plasma and examine its evolution with an electrostatic approximation. For the first time using a fully kinetic approach we show the emergence of the local instability, a transient growth, followed by classical Landau damping in a stable magnetized plasma. We show that the linearized Vlasov operator is non-normal leading to the algebraic growth of the perturbations using non-modal stability theory. The typical time scales of the obtained instabilities are of the order of several plasma periods. The first-order distribution function and the corresponding electric field are calculated and the dependence on the magnetic field and perturbation parameters is studied. Our results offer a new scenario of the emergence and development of plasma instabilities on the kinetic scale.

  15. Factors affecting the stability and performance of ionic liquid-based planar transient photodetectors.

    Science.gov (United States)

    Dalgleish, Simon; Reissig, Louisa; Hu, Laigui; Matsushita, Michio M; Sudo, Yuki; Awaga, Kunio

    2015-05-12

    A novel planar architecture has been developed for the study of photodetectors utilizing the transient photocurrent response induced by a metal/insulator/semiconductor/metal (MISM) structured device, where the insulator is an ionic liquid (IL-MISM). Using vanadyl 2,3-naphthalocyanine, which absorbs in the communications-relevant near-infrared wavelength region (λ(max,film) ≈ 850 nm), in conjunction with C60 as a bulk heterojunction, the high capacitance of the formed electric double layers at the ionic liquid interfaces yields high charge separation efficiency within the semiconductor layer, and the minimal potential drop in the bulk ionic liquid allows the electrodes to be offset by distances of over 7 mm. Furthermore, the decrease in operational speed with increased electrode separation is beneficial for a clear modeling of the waveform of the photocurrent signal, free from the influence of measurement circuitry. Despite the use of a molecular semiconductor as the active layer in conjunction with a liquid insulating layer, devices with a stability of several days could be achieved, and the operational stability of such devices was shown to be dependent solely on the solubility of the active layer in the ionic liquid, even under atmospheric conditions. Furthermore, the greatly simplified device construction process, which does not rely on transparent electrode materials or direct electrode deposition, provides a highly reproducible platform for the study of the electronic processes within IL-MISM detectors that is largely free from architectural constraints.

  16. Scanning transient current study of the I-V stabilization phenomena in silicon detectors irradiated by fast neutrons

    International Nuclear Information System (INIS)

    Eremin, V.; Verbitskaya, E.; Sidorov, A.; Fretwurst, E.; Lindstrom, G.

    1996-03-01

    Investigation of the I-V stabilization phenomena in neutron irradiated silicon detectors has been carried out using scanning transient current technique (STCT) on non-irradiated PP + -p-n + detectors. The PP + -p-n + detectors were used to simulate the PP + -n-n + detectors irradiated beyond the space charge sign inversion (SCSI). Two mechanisms partially responsible for the I- V stabilization have been identified

  17. Fuel pin integrity assessment under large scale transients

    International Nuclear Information System (INIS)

    Dutta, B.K.

    2006-01-01

    The integrity of fuel rods under normal, abnormal and accident conditions is an important consideration during fuel design of advanced nuclear reactors. The fuel matrix and the sheath form the first barrier to prevent the release of radioactive materials into the primary coolant. An understanding of the fuel and clad behaviour under different reactor conditions, particularly under the beyond-design-basis accident scenario leading to large scale transients, is always desirable to assess the inherent safety margins in fuel pin design and to plan for the mitigation the consequences of accidents, if any. The severe accident conditions are typically characterized by the energy deposition rates far exceeding the heat removal capability of the reactor coolant system. This may lead to the clad failure due to fission gas pressure at high temperature, large- scale pellet-clad interaction and clad melting. The fuel rod performance is affected by many interdependent complex phenomena involving extremely complex material behaviour. The versatile experimental database available in this area has led to the development of powerful analytical tools to characterize fuel under extreme scenarios

  18. Automated Assessment of Postural Stability (AAPS)

    Science.gov (United States)

    2016-10-01

    performed a battery of standard clinical tests of dynamic posture, whereas the fourth subject performed the stereotyped postures (e.g. movements restricted...Processing & Control [2] Napoli A, Ward C, Glass S, Tucker C, Obeid I (2016) “Automated Assessment of Postural Stability System,” IEEE Engineering in

  19. Morocco; Financial System Stability Assessment: Update

    OpenAIRE

    International Monetary Fund

    2008-01-01

    This paper presents an update to the Financial System Stability Assessment on Morocco. Major reforms have been achieved since the 2002 Financial Sector Assessment Program (FSAP) within a policy of actively promoting economic and financial sector opening. The 2002 FSAP recommendations have been largely implemented. Although the financial system is stable and considerably more robust than in the past, the liberalization of capital flows and increased exchange rate flexibility present challenges...

  20. Practical considerations in voltage stability assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kundur, P; Gao, B [Powertech Labs. Inc., Surrey, BC (Canada)

    1994-12-31

    This paper deals with some of the most important practical issues related to voltage stability assessment of large practical systems. A brief discussion of the practical aspects of voltage stability problem and prevention of voltage instability is given first, followed by descriptions of different analytical techniques and tools for voltage stability analysis. Presentations of analytical tools is focused on the VSTAB program which incorporates the modal analysis, continuation power flow, and shortest distance to instability techniques, Finally, an example case study of a practical large system is presented. The case study illustrates how modal analysis is used to determine the most effective load shedding scheme for preventing voltage instability. (author) 15 refs., 2 figs., 2 tabs.

  1. Real-time transient stabilization and voltage regulation of power generators with unknown mechanical power input

    International Nuclear Information System (INIS)

    Kenne, Godpromesse; Goma, Raphael; Nkwawo, Homere; Lamnabhi-Lagarrigue, Francoise; Arzande, Amir; Vannier, Jean Claude

    2010-01-01

    A nonlinear adaptive excitation controller is proposed to enhance the transient stability and voltage regulation of synchronous generators with unknown power angle and mechanical power input. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of relative angular speed, active electric power, infinite bus and generator terminal voltages. The operating conditions are computed online using the above physical available measurements, the terminal voltage reference value and the estimate of the mechanical power input. The proposed design is therefore capable of providing satisfactory voltage in the presence of unknown variations of the power system operating conditions. Using the concept of sliding mode equivalent control techniques, a robust decentralized adaptive controller which insures the exponential convergence of the outputs to the desired ones, is obtained. Real-time experimental results are reported, comparing the performance of the proposed adaptive nonlinear control scheme to one of the conventional AVR/PSS controller. The high simplicity of the overall adaptive control scheme and its robustness with respect to line impedance variation including critical unbalanced operating condition and temporary turbine fault, constitute the main positive features of the proposed approach.

  2. Real-time transient stabilization and voltage regulation of power generators with unknown mechanical power input

    Energy Technology Data Exchange (ETDEWEB)

    Kenne, Godpromesse, E-mail: gokenne@yahoo.co [Laboratoire d' Automatique et d' Informatique Appliquee (LAIA), Departement de Genie Electrique, Universite de Dschang, B.P. 134 Bandjoun (Cameroon); Goma, Raphael, E-mail: raphael.goma@lss.supelec.f [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Nkwawo, Homere, E-mail: homere.nkwawo@iutv.univ-paris13.f [Departement GEII, Universite Paris XIII, 99 Avenue Jean Baptiste Clement, 93430 Villetaneuse (France); Lamnabhi-Lagarrigue, Francoise, E-mail: lamnabhi@lss.supelec.f [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Arzande, Amir, E-mail: Amir.arzande@supelec.f [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Vannier, Jean Claude, E-mail: Jean-claude.vannier@supelec.f [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France)

    2010-01-15

    A nonlinear adaptive excitation controller is proposed to enhance the transient stability and voltage regulation of synchronous generators with unknown power angle and mechanical power input. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of relative angular speed, active electric power, infinite bus and generator terminal voltages. The operating conditions are computed online using the above physical available measurements, the terminal voltage reference value and the estimate of the mechanical power input. The proposed design is therefore capable of providing satisfactory voltage in the presence of unknown variations of the power system operating conditions. Using the concept of sliding mode equivalent control techniques, a robust decentralized adaptive controller which insures the exponential convergence of the outputs to the desired ones, is obtained. Real-time experimental results are reported, comparing the performance of the proposed adaptive nonlinear control scheme to one of the conventional AVR/PSS controller. The high simplicity of the overall adaptive control scheme and its robustness with respect to line impedance variation including critical unbalanced operating condition and temporary turbine fault, constitute the main positive features of the proposed approach.

  3. Fatigue status assessment for reactor pressure vessel based on actual operational transient

    International Nuclear Information System (INIS)

    Zhu Guangqiang; Liao Changbin; Dai Bing; Gui Chun

    2013-01-01

    Background: Fatigue is an important aging mechanism in RPV and it must be contained to aging management working range. Purpose: In order to ensure the safety operation of nuclear power plants, as extension of RPV service time, it is necessary to assess the fatigue damage caused by actual operation transient. Methods: Based on monitoring data of actual operation during the past eleven years, refer to design transient, the statistic analysis for types and occurrence times of actual transient is carried out, at the same time, every transients are combined as different operation cycles and the temperature field and stress field of typical components are analyzed by FEM. Results: Based on these information, fatigue analysis and assessment are finished, if later-actual transients are similar with the previous transients, the calculation result shows that the ratio between maximum of cumulative usage factors and design calculation value is 0.4967 the design transients is conservative. Conclusions: Fatigue status of RPV could be assessed and traced quickly through fatigue status assessment method in this paper based on actual operational transient and assessment result would be a good reference for RPV aging management. (authors)

  4. A Hierarchical Method for Transient Stability Prediction of Power Systems Using the Confidence of a SVM-Based Ensemble Classifier

    Directory of Open Access Journals (Sweden)

    Yanzhen Zhou

    2016-09-01

    Full Text Available Machine learning techniques have been widely used in transient stability prediction of power systems. When using the post-fault dynamic responses, it is difficult to draw a definite conclusion about how long the duration of response data used should be in order to balance the accuracy and speed. Besides, previous studies have the problem of lacking consideration for the confidence level. To solve these problems, a hierarchical method for transient stability prediction based on the confidence of ensemble classifier using multiple support vector machines (SVMs is proposed. Firstly, multiple datasets are generated by bootstrap sampling, then features are randomly picked up to compress the datasets. Secondly, the confidence indices are defined and multiple SVMs are built based on these generated datasets. By synthesizing the probabilistic outputs of multiple SVMs, the prediction results and confidence of the ensemble classifier will be obtained. Finally, different ensemble classifiers with different response times are built to construct different layers of the proposed hierarchical scheme. The simulation results show that the proposed hierarchical method can balance the accuracy and rapidity of the transient stability prediction. Moreover, the hierarchical method can reduce the misjudgments of unstable instances and cooperate with the time domain simulation to insure the security and stability of power systems.

  5. Neural-net based calculation of voltage dips at maximum angular swing in direct transient stability analysis [of power systems

    Energy Technology Data Exchange (ETDEWEB)

    Djukanovic, M [Inst. ' Nikola Tesla' , Belgrade (Yugoslavia); Sobajic, D J; Pao, Yohhan [Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Electrical Engineering and Applied Physics Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Computer Engineering and Science AI WARE inc., Cleveland, OH (United States)

    1992-10-01

    In heavily stressed power systems, post-fault transient voltage dips can lead to undesired tripping of industrial drives and large induction motors. The lowest transient voltage dips occur when fault clearing times are less than critical ones. In this paper, we propose a new iterative analytical methodology to obtain more accurate estimates of voltage dips at maximum angular swing in direct transient stability analysis. We also propose and demonstrate the possibility of storing the results of these computations in the associative memory (AM) system, which exhibits remarkable generalization capabilities. Feature-based models stored in the AM can be utilized for fast and accurate prediction of the location, duration and the amount of the worst voltage dips, thereby avoiding the need and cost for lengthy time-domain simulations. Numerical results obtained using the example of the New England power system are presented to illustrate our approach. (Author)

  6. Models for the transient stability of conventional power generating stations connected to low inertia systems

    Science.gov (United States)

    Zarifakis, Marios; Coffey, William T.; Kalmykov, Yuri P.; Titov, Sergei V.

    2017-06-01

    An ever-increasing requirement to integrate greater amounts of electrical energy from renewable sources especially from wind turbines and solar photo-voltaic installations exists and recent experience in the island of Ireland demonstrates that this requirement influences the behaviour of conventional generating stations. One observation is the change in the electrical power output of synchronous generators following a transient disturbance especially their oscillatory behaviour accompanied by similar oscillatory behaviour of the grid frequency, both becoming more pronounced with reducing grid inertia. This behaviour cannot be reproduced with existing mathematical models indicating that an understanding of the behaviour of synchronous generators, subjected to various disturbances especially in a system with low inertia requires a new modelling technique. Thus two models of a generating station based on a double pendulum described by a system of coupled nonlinear differential equations and suitable for analysis of its stability corresponding to infinite or finite grid inertia are presented. Formal analytic solutions of the equations of motion are given and compared with numerical solutions. In particular the new finite grid model will allow one to identify limitations to the operational range of the synchronous generators used in conventional power generation and also to identify limits, such as the allowable Rate of Change of Frequency which is currently set to ± 0.5 Hz/s and is a major factor in describing the volatility of a grid as well as identifying requirements to the total inertia necessary, which is currently provided by conventional power generators only, thus allowing one to maximise the usage of grid connected non-synchronous generators, e.g., wind turbines and solar photo-voltaic installations.

  7. Understanding chemical-potential-related transient pore-pressure response to improve real-time borehole (in)stability predictions

    Energy Technology Data Exchange (ETDEWEB)

    Tare, U. A.; Mody, F. K.; Mese, A. I. [Haliburton Energy Services, TX (United States)

    2002-07-01

    In order to develop a real-time wellbore (in)stability modelling capability, experimental work was carried out to investigate the role of the chemical potential of drilling fluids on transient pore pressure and time-dependent rock property alterations of shale formations. Time-dependent alterations in the pore pressure, acoustic and rock properties of formations subjected to compressive tri-axial test were recorded during the experiments involving the Pore Pressure Transmission (PPT) test. Based on the transient pore pressure of shale exposed to the test fluid presented here, the 20 per cent calcium chloride showed a very low membrane efficiency of 4.45 per cent. The need for a thorough understanding of the drilling fluid/shale interaction prior to applying any chemical potential wellbore (in)stability model to real-time drilling operations was emphasized. 9 refs., 5 figs.

  8. Artificial Intelligence Software for Assessing Postural Stability

    Science.gov (United States)

    Lieberman, Erez; Forth, Katharine; Paloski, William

    2013-01-01

    A software package reads and analyzes pressure distributions from sensors mounted under a person's feet. Pressure data from sensors mounted in shoes, or in a platform, can be used to provide a description of postural stability (assessing competence to deficiency) and enables the determination of the person's present activity (running, walking, squatting, falling). This package has three parts: a preprocessing algorithm for reading input from pressure sensors; a Hidden Markov Model (HMM), which is used to determine the person's present activity and level of sensing-motor competence; and a suite of graphical algorithms, which allows visual representation of the person's activity and vestibular function over time.

  9. Assessment of the Prony's method for BWR stability analysis

    International Nuclear Information System (INIS)

    Ortiz-Villafuerte, Javier; Castillo-Duran, Rogelio; Palacios-Hernandez, Javier C.

    2011-01-01

    Highlights: → This paper describes a method to determine the degree of stability of a BWR. → Performance comparison between Prony's and common AR techniques is presented. → Benchmark data and actual BWR transient data are used for comparison. → DR and f results are presented and discussed. → The Prony's method is shown to be a robust technique for BWR stability. - Abstract: It is known that Boiling Water Reactors are susceptible to present power oscillations in regions of high power and low coolant flow, in the power-flow operational map. It is possible to fall in one of such instability regions during reactor startup, since both power and coolant flow are being increased but not proportionally. One other possibility for falling into those areas is the occurrence of a trip of recirculation pumps. Stability monitoring in such cases can be difficult, because the amount or quality of power signal data required for calculation of the stability key parameters may not be enough to provide reliable results in an adequate time range. In this work, the Prony's Method is presented as one complementary alternative to determine the degree of stability of a BWR, through time series data. This analysis method can provide information about decay ratio and oscillation frequency from power signals obtained during transient events. However, so far not many applications in Boiling Water Reactors operation have been reported and supported to establish the scope of using such analysis for actual transient events. This work presents first a comparison of decay ratio and frequency oscillation results obtained by Prony's method and those results obtained by the participants of the Forsmark 1 and 2 Boiling Water Reactor Stability Benchmark using diverse techniques. Then, a comparison of decay ratio and frequency oscillation results is performed for four real BWR transient event data, using Prony's method and two other techniques based on an autoregressive modeling. The four

  10. Development of transient initiating event frequencies for use in probabilistic risk assessments

    International Nuclear Information System (INIS)

    Mackowiak, D.P.; Gentillon, C.D.; Smith, K.L.

    1985-05-01

    Transient initiating event frequencies are an essential input to the analysis process of a nuclear power plant probabilistic risk assessment. These frequencies describe events causing or requiring scrams. This report documents an effort to validate and update from other sources a computer-based data file developed by the Electric Power Research Institute (EPRI) describing such events at 52 United States commercial nuclear power plants. Operating information from the United States Nuclear Regulatory Commission on 24 additional plants from their date of commercial operation has been combined with the EPRI data, and the entire data base has been updated to add 1980 through 1983 events for all 76 plants. The validity of the EPRI data and data analysis methodology and the adequacy of the EPRI transient categories are examined. New transient initiating event frequencies are derived from the expanded data base using the EPRI transient categories and data display methods. Upper bounds for these frequencies are also provided. Additional analyses explore changes in the dominant transients, changes in transient outage times and their impact on plant operation, and the effects of power level and scheduled scrams on transient event frequencies. A more rigorous data analysis methodology is developed to encourage further refinement of the transient initiating event frequencies derived herein. Updating the transient event data base resulted in approx.2400 events being added to EPRI's approx.3000-event data file. The resulting frequency estimates were in most cases lower than those reported by EPRI, but no significant order-of-magnitude changes were noted. The average number of transients per year for the combined data base is 8.5 for pressurized water reactors and 7.4 for boiling water reactors

  11. Development of transient initiating event frequencies for use in probabilistic risk assessments

    Energy Technology Data Exchange (ETDEWEB)

    Mackowiak, D.P.; Gentillon, C.D.; Smith, K.L.

    1985-05-01

    Transient initiating event frequencies are an essential input to the analysis process of a nuclear power plant probabilistic risk assessment. These frequencies describe events causing or requiring scrams. This report documents an effort to validate and update from other sources a computer-based data file developed by the Electric Power Research Institute (EPRI) describing such events at 52 United States commercial nuclear power plants. Operating information from the United States Nuclear Regulatory Commission on 24 additional plants from their date of commercial operation has been combined with the EPRI data, and the entire data base has been updated to add 1980 through 1983 events for all 76 plants. The validity of the EPRI data and data analysis methodology and the adequacy of the EPRI transient categories are examined. New transient initiating event frequencies are derived from the expanded data base using the EPRI transient categories and data display methods. Upper bounds for these frequencies are also provided. Additional analyses explore changes in the dominant transients, changes in transient outage times and their impact on plant operation, and the effects of power level and scheduled scrams on transient event frequencies. A more rigorous data analysis methodology is developed to encourage further refinement of the transient initiating event frequencies derived herein. Updating the transient event data base resulted in approx.2400 events being added to EPRI's approx.3000-event data file. The resulting frequency estimates were in most cases lower than those reported by EPRI, but no significant order-of-magnitude changes were noted. The average number of transients per year for the combined data base is 8.5 for pressurized water reactors and 7.4 for boiling water reactors.

  12. Test Bench Development for Femur Stability Assessment

    Directory of Open Access Journals (Sweden)

    Samuel SANCHEZ-CABALLERO

    2015-01-01

    Full Text Available This paper shows the design and development of a test bench for humanfemurs. The main uses of this test bench will run from artificial femurs comparisonwith real femurs, to join stability assessment after bone a fracture repair. Amongthis uses is specially designed for condylar fractures testing. The test bench isdeveloped from a self-made existing tensile/compression testing machine. Thedesign procedure is supported by a literature review about the bone mechanicalbehavior and composition generally and the knee joint performance and repairparticularly. On the basis of this review, the machine was designed to simulate theadduction and abduction movements of the joint. The magnitudes to be measuredare: the compression force, the bone displacement (vertical and the knee jointrotation

  13. RELAP5/MOD2 Overview and Developmental. Assessment Results from TMl-1 Plant Transient Analysis

    International Nuclear Information System (INIS)

    Lin, J. C.; Tsai, C. C.; Ransom, V. H.; Johnsen, G. W.

    2013-01-01

    RELAP5/MOD2 is a new version of the RELAP5 thermal-hydraulic computer code containing improved modeling features that provide a generic capability for pressurized water reactor transient simulation. The objective of this paper is to provide code users with an overview of the code and to report developmental assessment results obtained from a Three Mile Island Unit One plant transient analysis. The assessment shows that the injection of highly sub-cooled water into a high-pressure primary coolant system does not cause unphysical results or pose a problem for RELAP5/MOD2. (author)

  14. SUMOylation of the Forkhead transcription factor FOXL2 promotes its stabilization/activation through transient recruitment to PML bodies.

    Directory of Open Access Journals (Sweden)

    Adrien Georges

    Full Text Available BACKGROUND: FOXL2 is a transcription factor essential for ovarian development and maintenance. It is mutated in the genetic condition called Blepharophimosis Ptosis Epicantus inversus Syndrome (BPES and in cases of isolated premature ovarian failure. We and others have previously shown that FOXL2 undergoes several post-translational modifications. METHODS AND PRINCIPAL FINDINGS: Here, using cells in culture, we show that interference with FOXL2 SUMOylation leads to a robust inhibition of its transactivation ability, which correlates with a decreased stability. Interestingly, FOXL2 SUMOylation promotes its transient recruitment to subnuclear structures that we demonstrate to be PML (Promyelocytic Leukemia Nuclear Bodies. Since PML bodies are known to be sites where post-translational modifications of nuclear factors take place, we used tandem mass spectrometry to identify new post-translational modifications of FOXL2. Specifically, we detected four phosphorylated, one sulfated and three acetylated sites. CONCLUSIONS: By analogy with other transcription factors, we propose that PML Nuclear Bodies might transiently recruit FOXL2 to the vicinity of locally concentrated enzymes that could be involved in the post-translational maturation of FOXL2. FOXL2 acetylation, sulfation, phosphorylation as well as other modifications yet to be discovered might alter the transactivation capacity of FOXL2 and/or its stability, thus modulating its global intracellular activity.

  15. Impact Study of PMSG-Based Wind Power Penetration on Power System Transient Stability Using EEAC Theory

    Directory of Open Access Journals (Sweden)

    Zhongyi Liu

    2015-11-01

    Full Text Available Wind turbines with direct-driven permanent magnet synchronous generators (PMSGs are widely used in wind power generation. According to the dynamic characteristics of PMSGs, an impact analysis of PMSG-based wind power penetration on the transient stability of multi-machine power systems is carried out in this paper based on the theory of extended equal area criterion (EEAC. Considering the most severe PMSG integration situation, the changes in the system’s equivalent power-angle relationships after integrating PMSGs are studied in detail. The system’s equivalent mechanical input power and the fault period electrical output power curves are found to be mainly affected. The analysis demonstrates that the integration of PMSGs can cause either detrimental or beneficial effects on the system transient stability. It is determined by several factors, including the selection of the synchronous generators used to balance wind power, the reactive power control mode of PMSGs and the wind power penetration level. Two different simulation systems are also adopted to verify the analysis results.

  16. Evaluation of the schemes of protections of Sistema Nacional Interconectado of year 2014 by analyzing the transient stability

    International Nuclear Information System (INIS)

    Rojas Rojas, Luis Felipe

    2012-01-01

    The elaboration of a study of transient stability is seen as part of the planning process associated with the Plan de Expansion de la Transmision. Studies have historically contemplated the calculation of critics times of release of failures without allowing to obtain conclusive information about the performance of protection systems. An evaluation of the protection schemes of substations is determined make of the Sistema Nacional Interconectado of year 2014. Analysis of transient stability was used to verify compliance with the ''Criterios de Seguridad para la Planificacion, Diseno y Operacion del Sistema Electrico Nacional'' and ''Criterios de Calidad, Seguridad y Desempeno'' of the Reglamento del Mercado Electrico Regional in order to determine the necessary improvements. A methodology is proposed for simulating the behavior of protection systems using the software PSS/E, which has replaced the methodology based on the calculation of critical times. The presence of 42 substations were determined in which the release of failures for remote backup has caused unstable conditions of the system. 174 improvements have identified as necessary among which are: the implementation of distance relays in autotransformers, differential protections in reactors, differentials of lines and overcurrents of definite time in lines, duplication of differentials in bars, the replacement of pole breakers for monopolar and duplication of breakers of link bars. The current criteria have been recommended to supplement with probabilistic criteria to avoid incurring unnecessary investments. (author) [es

  17. Assessment of trace element stabilization in soil

    OpenAIRE

    Kumpiene, Jurate

    2005-01-01

    The thesis deals with the remediation of trace element contaminated soil by the chemical stabilization technique. The objective is to complement the knowledge about possibilities of applying the stabilization either (1) as an alternate soil remediation method to excavation and landfilling or (2) for a pre-treatment of contaminated soil before landfilling. The work is based on two case studies of the stabilization of 1) Cr, Cu, As, and Zn contaminated soil using metallic iron and 2) Pb and Cu ...

  18. Stability analysis of the Backward Euler time discretization for the pin-resolved transport transient reactor calculation

    International Nuclear Information System (INIS)

    Zhu, Ang; Xu, Yunlin; Downar, Thomas

    2016-01-01

    Three-dimensional, full core transport modeling with pin-resolved detail for reactor dynamic simulation is important for some multi-physics reactor applications. However, it can be computationally intensive due to the difficulty in maintaining accuracy while minimizing the number of time steps. A recently proposed Transient Multi-Level (TML) methodology overcomes this difficulty by use multi-level transient solvers to capture the physical phenomenal in different time domains and thus maximize the numerical accuracy and computational efficiency. One major problem with the TML method is the negative flux/precursor number density generated using large time steps for the MOC solver, which is due to the Backward Euler discretization scheme. In this paper, the stability issue of Backward Euler discretization is first investigated using the Point Kinetics Equations (PKEs), and the predicted maximum allowed time step for SPERT test 60 case is shown to be less than 10 ms. To overcome this difficulty, linear and exponential transformations are investigated using the PKEs. The linear transformation is shown to increase the maximum time step by a factor of 2, and the exponential transformation is shown to increase the maximum time step by a factor of 5, as well as provide unconditionally stability above a specified threshold. The two sets of transformations are then applied to TML scheme in the MPACT code, and the numerical results presented show good agreement for standard, linear transformed, and exponential transformed maximum time step between the PKEs model and the MPACT whole core transport solution for three different cases, including a pin cell case, a 3D SPERT assembly case and a row of assemblies (“striped assembly case”) from the SPERT model. Finally, the successful whole transient execution of the stripe assembly case shows the ability of the exponential transformation method to use 10 ms and 20 ms time steps, which all failed using the standard method.

  19. improving the transient stability of Nigerian 330kV transmission

    African Journals Online (AJOL)

    eobe

    The overloaded lines which could excite instability in the network are identified. ... stability of the network is analysed by determining the critical clearing time of the acute generators when a ...... economic analysis of stand-alone hybrid energy.

  20. Summary of PRA assessment of transient accident risks, human factors considerations, and PRA methods and applications

    International Nuclear Information System (INIS)

    Carnino, A.

    1984-01-01

    This chapter reviews the progress made in the probabilistic risk assessment (PRA) area to help in solving operational transient problems and to integrate human factors considerations, as discussed at the American Nuclear Society Topical Meeting on Anticipated and Abnormal Plant Transients in Light Water Reactors. Topics considered include core-melt frequency, external events (e.g., fires, floods), diagnostic errors, and operator aids. It is concluded that confidence in PRA results, predictions and uses for decisions in both the safety of the plants and their availability will improve

  1. Computationally Efficient Transient Stability Modeling of multi-terminal VSC-HVDC

    DEFF Research Database (Denmark)

    van der Meer, Arjen A; Rueda-Torres, José; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper studies the inclusion of averaged VSC-based grid interfaces and HVDC networks into stability type simulations, and compares the accuracy and speed of three multi-terminal DC dynamic models: 1) a state-space based model, 2) a multi-rate improved model, and 3) a reduced-order model...

  2. Transient stability of DFIG wind turbines at an external short-circuit fault

    DEFF Research Database (Denmark)

    Sun, Tao; Chen, Zhe; Blaabjerg, Frede

    2005-01-01

    The fast development of wind power generation brings new requirements for wind turbine integration into the network. After clearance of an external short-circuit fault, gridconnected wind turbines should restore their normal operation without power loss caused by disconnections. This article...... are described in detail. The transient process of grid-connected wind turbines with DFIGs at an external shortcircuit fault is analysed, and in critical post-fault situations a measure is proposed for the voltage recovery of DFIG wind turbines after fault clearance. Simulation results demonstrate...... that in uncritical post-fault situations the control schemes are able to restore the wind turbine's normal operation without disconnections.lt is also proved that the proposed measure is effective in re-establishing the voltage at the wind turbine terminal in critical post-fault situations....

  3. Detailed investigation of current transients from metastable pitting events on stainless steel - the transition to stability

    International Nuclear Information System (INIS)

    Pistorius, P.C.; Burstein, G.T.

    1992-01-01

    Current transients which result from metastable pitting events (on Type 304 stainless steel in an acidic solution containing 1 M Cl - ) are presented. A criterion for the stable growth of open hemispherical pits is developed; the criterion states that the product of current density and pit depth must exceed a certain minimum value, to sustain rapid dissolution. Analysis of the transients from metastable pits shows that these pits fall short of this minimum, as do stable pits initially. The growth of these pits thus requires the presence of another barrier to diffusion, which is thought to be a remnant of the passive film; this forms a flawed cover over the pit mouth. When this cover ruptures under the influence of osmotic pressure, the pit repassivates. Pits growing at higher current densities approach the minimum requirement for stable growth more closely. A ''pitting potential'' results from the effect that metastable pits formed at more positive potentials grow at higher current densities, and are thus more likely to grow into stable pits. The effect of potential on the current density does not result from either activation control or ohmic control; rather, the pits grow under diffusion control. A change, with potential, of the type of pit site which can be activated, causes the potential dependence of the distribution of current densities in metastable pits. Although the distribution of current densities changes with potential, each metastable pit grows under diffusion control with a current density which is independent of the potential; this is confirmed by polarisation tests on growing metastable pits

  4. Usefulness of cardiotoxicity assessment using calcium transient in human induced pluripotent stem cell-derived cardiomyocytes.

    Science.gov (United States)

    Watanabe, Hitoshi; Honda, Yayoi; Deguchi, Jiro; Yamada, Toru; Bando, Kiyoko

    2017-01-01

    Monitoring dramatic changes in intracellular calcium ion levels during cardiac contraction and relaxation, known as calcium transient, in human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) would be an attractive strategy for assessing compounds on cardiac contractility. In addition, as arrhythmogenic compounds are known to induce characteristic waveform changes in hiPSC-CMs, it is expected that calcium transient would allow evaluation of not only compound-induced effects on cardiac contractility, but also compound arrhythmogenic potential. Using a combination of calcium transient in hiPSC-CMs and a fast kinetic fluorescence imaging detection system, we examined in this study changes in calcium transient waveforms induced by a series of 17 compounds that include positive/negative inotropic agents as well as cardiac ion channel activators/inhibitors. We found that all positive inotropic compounds induced an increase in peak frequency and/or peak amplitude. The effects of a negative inotropic compound could clearly be detected in the presence of a β-adrenergic receptor agonist. Furthermore, most arrhythmogenic compounds raised the ratio of peak decay time to peak rise time (D/R ratio) in calcium transient waveforms. Compound concentrations at which these parameters exceeded cutoff values correlated well with systemic exposure levels at which arrhythmias were reported to be evoked. In conclusion, we believe that peak analysis of calcium transient and determination of D/R ratio are reliable methods for assessing compounds' cardiac contractility and arrhythmogenic potential, respectively. Using these approaches would allow selection of compounds with low cardiotoxic potential at the early stage of drug discovery.

  5. Energy Management System Based on Fuzzy fractional order PID Controller for Transient Stability Improvement in Microgrids with Energy Storage

    DEFF Research Database (Denmark)

    Moafi, Milad; Marzband, Mousa; Savaghebi, Mehdi

    2016-01-01

    in the islanded Microgrid (MG). To increase performance for a wide range of power system operating conditions, an energy management systems (EMS) is proposed based on a fuzzy fractional order PID (FFOPID) controller. It is able to analyze and simulate the dynamic behavior in grid connected MGs. This controller...... is proposed in the MG encompassing distributed generation resources with “plug and play” ability. The performance of FFOPID controller is verified for frequency control purposes and to support internal bus voltage in both islanded and grid connected operating modes in accordance with the failure time. Energy...... combined with a PID-controller (termed as FLPID) and Fuzzy fractional order PID (termed as FFOPID) are implemented according to the characteristics and limitations of overloading and state of charge (SOC). The obtained results show good performance of FFOPID controllers by improving the transient stability...

  6. Soft interactions and volume exclusion by polymeric crowders can stabilize or destabilize transient structure in disordered proteins depending on polymer concentration.

    Science.gov (United States)

    Rusinga, Farai I; Weis, David D

    2017-08-01

    The effects of macromolecular crowding on the transient structure of intrinsically disordered proteins is not well-understood. Crowding by biological molecules inside cells could modulate transient structure and alter IDP function. Volume exclusion theory and observations of structured proteins suggest that IDP transient structure would be stabilized by macromolecular crowding. Amide hydrogen exchange (HX) of IDPs in highly concentrated polymer solutions would provide valuable insights into IDP transient structure under crowded conditions. Here, we have used mass spectrometry to measure HX by a transiently helical random coil domain of the activator of thyroid and retinoid receptor (ACTR) in solutions containing 300 g L -1 and 400 g L -1 of Ficoll, a synthetic polysaccharide, using a recently-developed strong cation exchange-based cleanup method [Rusinga, et al., Anal Chem 2017;89:1275-1282]. Transiently helical regions of ACTR exchanged faster in 300 g L -1 Ficoll than in dilute buffer. In contrast, one transient helix exchanged more slowly in 400 g L -1 Ficoll. Nonspecific interactions destabilize ACTR helicity in 300 g L -1 Ficoll because ACTR engages with the Ficoll polymer mesh. In contrast, 400 g L -1 Ficoll is a semi-dilute solution where ACTR cannot engage the Ficoll mesh. At this higher concentration, volume exclusion stabilizes ACTR helicity because ACTR is compacted in interstitial spaces between Ficoll molecules. Our results suggest that the interplay between nonspecific interactions and volume exclusion in different cellular compartments could modulate IDP function by altering the stability of IDP transient structures. Proteins 2017; 85:1468-1479. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. Preliminary Assessment of Transient of Over Power Accident for DSFR-600

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Andong; Bae, Moohoon; Suh, Namduk [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-10-15

    TRACE code was selected as one of candidates for audit code, so sodium properties and heat transfer model in the code was verified first. On the basis of MARS-LMR code input, DSFR-600 TRACE model was developed and applied to PHTS tube rupture case, one of design base events (DBE) of DSFR-600. In this study, Transients of Over Power (TOP) event is assessed using TRACE code as one another case of DBEs of DSFR-600 for preparation of audit calculation of PGSFR.One of the design base events, transients of over power of Demonstration Sodium cooled Fast Reactor was simulated using TRACE code. Predicted fuel temperature showed that the peak fuel temperature occurs when the reactor scrammed and predicted temperature was similar to the MARS-LMRs assessment by KAERI. In this study, it is found that the second peak of fuel temperature is influenced by the inventory of steam generator and the natural circulation characteristic of the reactor vessel pool. Pre-calculation of the unprotected transients of over power with conservative reactivity assumption showed that this assumption is conservative in design base even assessment. However the method of measurement and applying the core radial, fuel and control rod axial expansion reactivity feedback is crucial in BDBE assessment of SFR.

  8. Understanding chemical-potential-related transient pore-pressure response to improve real-time borehole (in)stability predictions

    Energy Technology Data Exchange (ETDEWEB)

    Tare, U.A.; Mody, F.K.; Mese, A.I. [Halliburton Energy Services, Cairo (Egypt)

    2000-11-01

    Experimental studies were conducted to explain the concept of a real-time wellbore (in)stability logging methodology. The role of the chemical potential of drilling fluids on transient pore pressure and time-dependent rock property alterations of shale formations was examined by providing details about a pore pressure transmission (PPT) test. The PPT experiments exposed formation (shale) cores under simulated downhole conditions to various salt solutions and drilling fluids. The main objective was to translate the results of the PPT tests to actual drilling conditions. A 20 per cent w/w calcium chloride solution was exposed to a Pierre II shale under high pressure in the PPT apparatus. The PPT test was used to estimate the impact of a drilling fluid on shale pore pressure. The efficiency of the salt solution/shale system was also estimated. Estimates of the dynamic rock properties were made based on the obtained acoustic data. It was determined that in order to accurately model time-dependent wellbore (in)stability in the field, it is important to calibrate representative shale core response to drilling fluids under realistic in-situ conditions. The 20 per cent w/w calcium chloride solution showed very low membrane efficiency of 4.45 per cent. It was concluded that changes in the shale dynamic rock properties as a function of test fluid exposure can be obtained from the simultaneous acquisition of sonic compression and shear wave velocity data. 12 refs., 5 figs.

  9. Assessment of stability characteristics of MFTF coils

    International Nuclear Information System (INIS)

    1979-03-01

    Certain aspects of the MFTF (Mirror Fusion Test Facility) conductor performance were investigated. Recovery analysis of the MFTF conductor was studied using GA's stability code. The maximum length of uncooled, unsoldered composite core which can recover from a thermal excursion was determined analytically. A maximum credible mechanical disturbance in terms of energy deposition, conductor motion and length, and time duration, was postulated. 5 references, 4 figures

  10. The Bahamas; Financial Sector Stability Assessment

    OpenAIRE

    International Monetary Fund

    2013-01-01

    This article is an overview of the structure of the Bahamian financial system. After the financial crisis in the United States, the Bahamian financial structure showed fragile growth. Tourism, the main source of income for the domestic economy, weakened owing to the U.S. crisis. The increase in oil prices was the key reason for the destroyed infrastructure. However, amidst the vulnerabilities, the banking sector showed stability with high capital and liquidity and sustained challenges; the in...

  11. Assessment of Nutrient Stability in Space Foods

    Science.gov (United States)

    Zwart, S. R.; Perchonok, M.; Braby, L. A.; Kloeris, V. A.; Smith, S. M.

    2009-01-01

    Maintaining an intact nutrient supply in the food system flown on spacecraft is a critical issue for mission success and crew health and safety. Early polar expeditions and exploration expeditions by sailing vessels have taught us that a deficiency, or excess, of even a single vitamin in the food supply can be catastrophic. Evidence from ground-based research indicates that some vitamins are destroyed and fatty acids are oxidized (and therefore rendered dangerous or useless) by different types of radiation and by conditions of long-term storage. We hypothesize that radiation and long-term storage in the space-flight environment will affect the stability of vitamins, amino acids, and fatty acids in the space food system. The research objectives of our ongoing stability studies are to determine the stability of water- and fat-soluble vitamins, fatty acids, and amino acids in the space food supply before and after space flight on the International Space Station (ISS). Foods were analyzed after 2 weeks (a flight control), 11, 19, and 28 months of flight. Along with the space-flown foods, ground-based controls matched for time, light, and temperature are analyzed. The flight studies complement planned ground-based studies of the effects of radiation on vitamins, amino acids, and fatty acids. Flight studies are needed because a model based on ground-based data cannot predict all of the effects of the space-flight environment. Flight studies provide a more accurate test system to determine the effects on these nutrients of the temperature, and radiation conditions in the space-flight environment. Ground studies are required to evaluate longer missions and higher radiation levels expected outside low-Earth orbit. In addition to providing information about nutrient stability in space, the results of these studies will help NASA determine if a need exists to develop special packaging that can ensure stability of foods and nutrients in space, or if further studies of nutrient

  12. Assessment of the turbine trip transient in Cofrentes NPP with TRAC-BF1

    International Nuclear Information System (INIS)

    Castrillo, F.; Gomez, A.; Gallego, I.

    1993-06-01

    This report presents the results of the assessment of TRAC-BF1 (G1-J1) code with the model of C. N. Cofrentes for simulation of the transient originated by the manual trip of the main turbine. C. N. Cofrentes is a General Electric designed BWR/6 plant, with a nominal core thermal power of 2894 Mwt, in commercial operation since 1985, owned and operated by Hidroelectrica Espanola, S. A. The plant incorporates all the characteristics of BWR/6 reactors, with two turbine driven FW pumps. As a result of this assessment a model of C. N. Cofrentes has been developed for TRAC-BF1 that fairly reproduces operational transient behavior of the plant. A special purpose code was generated to obtain reactivity coefficients, as required by TRAC-BF1, from the 3D simulator

  13. Cognitive human reliability analysis for an assessment of the safety significance of complex transients

    International Nuclear Information System (INIS)

    Amico, P.J.; Hsu, C.J.; Youngblood, R.W.; Fitzpatrick, R.G.

    1989-01-01

    This paper reports that as part of a probabilistic assessment of the safety significance of complex transients at certain PWR power plants, it was necessary to perform a cognitive human reliability analysis. To increase the confidence in the results, it was desirable to make use of actual observations of operator response which were available for the assessment. An approach was developed which incorporated these observations into the human cognitive reliability (HCR) modeling approach. The results obtained provided additional insights over what would have been found using other approaches. These insights were supported by the observations, and it is suggested that this approach be considered for use in future probabilistic safety assessments

  14. Compilation of Quality Assurance Documentation for Analyses Performed for the Resumption of Transient Testing Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, Annette L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Sondrup, A. Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-11-01

    This is a companion document to the analyses performed in support of the environmental assessment for the Resumption of Transient Fuels and Materials Testing. It is provided to allow transparency of the supporting calculations. It provides computer code input and output. The basis for the calculations is documented separately in INL (2013) and is referenced, as appropriate. Spreadsheets used to manipulate the code output are not provided.

  15. Structural Integrity Assessment of VVER-1000 RPV under Accidental Cool down Transients

    International Nuclear Information System (INIS)

    Shrivastav, V.; Sen, R.N.; Yadav, R.S.

    2012-01-01

    Corrosion, Fatigue and Irradiation embrittlement are the major degradation mechanisms responsible for ageing of RPV (and its internals) of a Pressurized Water Reactor. While corrosion and fatigue can generate cracks, irradiation damage can lead to brittle fracture initiating from these cracks. Ageing in nuclear power plants needs to be managed so as to ensure that design functions remain available throughout the life of the plant. From safety perspective, this implies that ageing degradation of systems, structures and components important to safety remain within acceptable limits. Reactor Pressure Vessel has been identified as the highest priority key component in plant life management for Pressurized Water Reactors. Therefore special attention is required to ensure its structural integrity during its lifetime. In this paper, structural integrity assessment for typical VVER-1000 RPV is carried out under severe accidental cool down transients using the Finite Element Method. Three different accidental scenarios are postulated and safety of the vessel is conservatively assessed under these transients using the Linear Elastic Fracture Mechanics approach. Transient thermo mechanical stress analysis of the core belt region of the RPV is carried out in presence of postulated cracks and stress intensity factors are calculated and compared with the material fracture toughness to assess the structural integrity of the vessel. The paper also include some parametric analyses to justify the methodology. (author)

  16. Assessing Power System Stability Following Load Changes and Considering Uncertainty

    Directory of Open Access Journals (Sweden)

    D. V. Ngo

    2018-04-01

    Full Text Available An increase in load capacity during the operation of a power system usually causes voltage drop and leads to system instability, so it is necessary to monitor the effect of load changes. This article presents a method of assessing the power system stability according to the load node capacity considering uncertainty factors in the system. The proposed approach can be applied to large-scale power systems for voltage stability assessment in real-time.

  17. Transient Growth Analysis of Compressible Boundary Layers with Parabolized Stability Equations

    Science.gov (United States)

    Paredes, Pedro; Choudhari, Meelan M.; Li, Fei; Chang, Chau-Lyan

    2016-01-01

    The linear form of parabolized linear stability equations (PSE) is used in a variational approach to extend the previous body of results for the optimal, non-modal disturbance growth in boundary layer flows. This methodology includes the non-parallel effects associated with the spatial development of boundary layer flows. As noted in literature, the optimal initial disturbances correspond to steady counter-rotating stream-wise vortices, which subsequently lead to the formation of stream-wise-elongated structures, i.e., streaks, via a lift-up effect. The parameter space for optimal growth is extended to the hypersonic Mach number regime without any high enthalpy effects, and the effect of wall cooling is studied with particular emphasis on the role of the initial disturbance location and the value of the span-wise wavenumber that leads to the maximum energy growth up to a specified location. Unlike previous predictions that used a basic state obtained from a self-similar solution to the boundary layer equations, mean flow solutions based on the full Navier-Stokes (NS) equations are used in select cases to help account for the viscous-inviscid interaction near the leading edge of the plate and also for the weak shock wave emanating from that region. These differences in the base flow lead to an increasing reduction with Mach number in the magnitude of optimal growth relative to the predictions based on self-similar mean-flow approximation. Finally, the maximum optimal energy gain for the favorable pressure gradient boundary layer near a planar stagnation point is found to be substantially weaker than that in a zero pressure gradient Blasius boundary layer.

  18. Guernsey; Financial System Stability Assessment-Update

    OpenAIRE

    International Monetary Fund

    2011-01-01

    Guernsey is a leading international insurance center in Europe. Its economy purely depends on the performance of the financial sector. As per the 2003 assessment under the Offshore Financial Center (OFC) program, it is found that the Guernsey Financial Services Commission (GFSC)’s powers have been strengthened in recent years and many recommendations of the 2003 Financial Sector Assessment Program (FSAP) have been implemented. The GFSC has developed a strategy for addressing banks' financial ...

  19. Transient stability enhancement of wind farms using power electronics and facts controllers

    Science.gov (United States)

    Mohammadpour, Hossein Ali

    network, and the frequency of the exchanged energy is below the fundamental frequency of the system. This phenomenon may cause severe damage in the wind farm, if not prevented. Therefore, this dissertation deals with the SSR phenomena in a capacitive series compensated wind farm. A DFIG-based wind farm, which is connected to a series compensated transmission line, is considered as a case study. The small-signal stability analysis of the system is presented, and the eigenvalues of the system are obtained. Using both modal analysis and time-domain simulation, it is shown that the system is potentially unstable due to the SSR mode. Then, three different possibilities for the addition of SSR damping controller (SSRDC) are investigated. The SSRDC can be added to (1) gate-controlled series capacitor (GCSC), (2) thyristor-controlled series capacitor (TCSC), or (3) DFIG rotor-side converter (RSC) and grid-side converter (GSC) controllers. The first and second cases are related to the series flexible AC transmission systems (FACTS) family, and the third case uses the DFIG back-to-back converters to damp the SSR. The SSRDC is designed using residue-based analysis and root locus diagrams. Using residue-based analysis, the optimal input control signal (ICS) to the SSRDC is identified that can damp the SSR mode without destabilizing other modes, and using root-locus analysis, the required gain for the SSRDC is determined. Moreover, two methods are discussed in order to estimate the optimum input signal to the SSRDC, without measuring it directly. In this dissertation, MATLAB/Simulink is used as a tool for modeling and design of the SSRDC, and PSCAD/EMTDC is used to perform time-domain simulation in order to verify the design process.

  20. Assessment of remedial control schemes for damping transient oscillations in the Mexican system

    Energy Technology Data Exchange (ETDEWEB)

    Castellanos, R.B.; Sarmiento, H.U.; Pampin, G. [Inst.de Investigaciones Electricas, Morelos (Mexico); Messina, A.R. [Cinvestav, San Pedro Zacatenco (Mexico)

    2008-07-01

    In order to enhance voltage control and power system dynamic performance, special protection systems (SPS) are increasingly being used in the Mexican Interconnected System (MIS). These include extensive use of direct load shedding schemes, generator tripping schemes, controlled disconnection of lines, and automatic generation rejection and single phase reclosing schemes. Generator tripping based on local detection of severe disturbance is of particular importance and has been used to enhance transient stability. In addition, the onset of system instability has become more complex, often involving interactions between major system modes. Post-fault transient oscillations have become more common following the loss of major system elements and may result in uncontrolled system separation. This has motivated the need to develop system-wide special protection systems. This paper explored the possible benefits and feasibility of employing SPSs to mitigate wide-area inter-area oscillations in the MIS. The paper described the exploratory studies such as the coordinated application of automatic generation tripping schemes and automatic load shedding to enhance system dynamic performance. The paper also explained sensitivity studies that were conducted to determine the amount and location of generation (load) to be shed and suggested extensions to the basic security criteria to maintain network stability. The proposed techniques were developed and tested on a large-scale representation of the Mexican system that included the operation of several FACTS controllers. It was concluded that automatic generation shedding and automatic loading shedding were efficient alternatives to improve generation and transmission use, reliability and flexibility. 7 refs., 1 tab., 3 figs.

  1. Assessing Grasp Stability Based on Learning and Haptic Data

    DEFF Research Database (Denmark)

    Bekiroglu, Yasemin; Laaksonen, Janne; Jørgensen, Jimmy Alison

    2011-01-01

    a probabilistic learning framework to assess grasp stability and demonstrate that knowledge about grasp stability can be inferred using information from tactile sensors. Experiments on both simulated and real data are shown. The results indicate that the idea to exploit the learning approach is applicable...... data and machine-learning methods, including AdaBoost, support vector machines (SVMs), and hidden Markov models (HMMs). In particular, we study the effect of different sensory streams to grasp stability. This includes object information such as shape; grasp information such as approach vector; tactile...

  2. Assessment of the mechanical stability of underground excavations

    International Nuclear Information System (INIS)

    Kuroki, Shigemori; Taniguchi, Wataru

    1999-01-01

    Each tunnel in the underground high level radioactive waste repository must be mechanically stable to maintain safety throughout the construction, emplacement operations and closure phase. The mechanical stability of underground excavations were assessed using a theoretical analysis and a finite element method taking a wide range of geological environment in Japan into consideration to establish confidence in the construction of disposal facilities. The results show that it is possible to maintain the mechanical stability with adequate tunnel spacing and disposal pit pitch and proper mechanical support. The procedure used for the analysis of the mechanical stability in the H12 report and the results are described in this report. (author)

  3. Construction of climate change scenarios from transient climate change experiments for the IPCC impacts assessment

    International Nuclear Information System (INIS)

    Viner, D.; Hulme, M.; Raper, S.C.B.; Jones, P.D.

    1994-01-01

    This paper outlines the different methods which may be used for the construction of regional climate change scenarios. The main focus of the paper is the construction of global climate change scenarios from climate change experiments carried out using General Circulation Models (GCMS) An introduction to some GCM climate change experiments highlights the difference between model types and experiments (e.g., equilibrium or transient). The latest generation of climate change experiments has been performed using fully coupled ocean-atmosphere GCMS. These allow transient simulations of climate change to be performed with respect to a given greenhouse gas forcing scenario. There are, however, a number of problems with these simulations which pose difficulties for the construction of climate change scenarios for use in climate change impacts assessment. The characteristics of the transient climate change experiments which pose difficulties for the construction of climate change scenarios are discussed. Three examples of these problems are: different climate change experiments use different greenhouse gas concentration scenarios; the 'cold-start' problem makes it difficult to link future projections of climate change to a given calendar year; a drift of the climate is noticeable in the control simulations. In order to construct climate change scenarios for impacts assessment a method has therefore to be employed which addresses these problems. At present the climate modeling and climate change impacts communities are somewhat polarized in their approach to spatial scales. Current GCMs model the climate at resolutions larger than 2.5 x 3.75 degree, while the majority of impacts assessment studies are undertaken at scales below 50km (or 0.5 degree). This paper concludes by addressing the problems in bringing together these two different modeling perspectives by presenting a number of regional climate change scenarios. 35 refs., 8 figs., 2 tabs

  4. Assessing fly ash treatment: Remediation and stabilization of heavy metals

    DEFF Research Database (Denmark)

    Lima, A.T.; Ottosen, Lisbeth M.; Ribeiro, Alexandra B.

    2012-01-01

    Fly ashes from Municipal Solid Waste (MSW), straw (ST) and co-combustion of wood (CW) are here analyzed with the intent of reusing them. Two techniques are assessed, a remediation technique and a solidification/stabilization one. The removal of heavy metals from fly ashes through the electrodialy......Fly ashes from Municipal Solid Waste (MSW), straw (ST) and co-combustion of wood (CW) are here analyzed with the intent of reusing them. Two techniques are assessed, a remediation technique and a solidification/stabilization one. The removal of heavy metals from fly ashes through...

  5. Transient Social-Ecological Stability: the Effects of Invasive Species and Ecosystem Restoration on Nutrient Management Compromise in Lake Erie

    Directory of Open Access Journals (Sweden)

    Eric D. Roy

    2010-03-01

    Full Text Available Together, lake ecosystems and local human activity form complex social-ecological systems (SESs characterized by feedback loops and discontinuous change. Researchers in diverse fields have suggested that complex systems do not have single stable equilibria in the long term because of inevitable perturbation. During this study, we sought to address the general question of whether or not stable social-ecological equilibria exist in highly stressed and managed lacustrine systems. Using an integrated human-biophysical model, we investigated the impacts of a species invasion and ecosystem restoration on SES equilibrium, defined here as a compromise in phosphorus management among opposing stakeholders, in western Lake Erie. Our integrated model is composed of a calibrated ecological submodel representing Sandusky Bay, and a phosphorus management submodel that reflects the societal benefits and costs of phosphorus regulation. These two submodels together form a dynamic feedback loop that includes freshwater ecology, ecosystem services, and phosphorus management. We found that the invasion of dreissenid mussels decreased ecosystem resistance to eutrophication, necessitating increased phosphorus management to preserve ecosystem services and thus creating the potential for a shift in social-ecological equilibrium. Additionally, our results suggest that net benefits in the region following the invasion of dreissenids may never again reach the pre-invasion level if on-site phosphorus control is the sole management lever. Further demonstrating transient system stability, large-scale wetland restoration shifted points of management compromise to states characterized by less on-site phosphorus management and higher environmental quality, resulting in a significant increase in net benefits in the region. We conclude that lacustrine SESs are open and dynamic, and we recommend that future models of these systems emphasize site-specific perturbation over

  6. Transient stability analysis in electric power systems with frequency dependent loads; Analise de estabilidade transitoria em sistemas eletricos de potencia com cargas dependentes da frequencia

    Energy Technology Data Exchange (ETDEWEB)

    Alberto, Luis F. Costa; Borelli, Jose Renato; Bretas, Newton G. [Sao Paulo Univ., Sao Carlos, SP (Brazil). Dept. de Engenharia Eletrica

    1997-12-31

    The power system models normally used to transient stability analysis are very simplified. Damping effects such as frequency dependent loads are neglected. In order to incorporate these effects in the analysis, a frequency dependent load model is proposed, and it is shown the important influence that it causes in the critical clearing times for stability analysis beyond the first swing. this load model require the network structure preservation and the knowledge of frequency of non-generator buses. In this work, an efficient method to estimate the frequencies of non-generator buses was developed. (author) 11 refs., 5 figs., 2 tabs.; e-mail: ngbretas at sel.eesc.sc.usp.br

  7. Incentives and stability of international climate coalitions: An integrated assessment

    International Nuclear Information System (INIS)

    Bosetti, Valentina; Carraro, Carlo; De Cian, Enrica; Massetti, Emanuele; Tavoni, Massimo

    2013-01-01

    This paper analyses the incentives to participate in an international climate agreement and the stability of the resulting climate coalition using the integrated assessment model WITCH. Coalition stability is assessed under alternative assumptions concerning the pure rate of time preference, the aggregation of social welfare, and the severity of climate damages. The profitability, stability, and strong potential internal stability of a number of coalitions, those potentially effective in reducing GHG emissions, is explored in the paper. The main conclusion is that only the grand coalition, i.e. a coalition where all world regions cooperate to reduce emissions, can maintain GHG concentration below 550 ppm CO 2 -eq. However, this coalition is not internally stable, even when allowing for monetary transfers across world regions. Nonetheless, the paper also shows that strongly potentially internally stable coalitions exist, though of smaller size, which can mitigate global warming and limit GHG concentrations to 600 ppm CO 2 -eq. - Highlights: ► We analyse climate coalitions with an integrated assessment model. ► Coalitions’ profitability and stability is analysed under alternative assumptions. ► Effective coalitions should include larger emitters (such as India and China). ► A coalition that achieves 550 ppm CO 2 -eq is not internally stable. ► A stable coalition can achieve around 518 ppme in 2050 and 600 ppme in 2100

  8. Transient stability enhancement of wind farms connected to a multi-machine power system by using an adaptive ANN-controlled SMES

    International Nuclear Information System (INIS)

    Muyeen, S.M.; Hasanien, Hany M.; Al-Durra, Ahmed

    2014-01-01

    Highlights: • We present an ANN-controlled SMES in this paper. • The objective is to enhance transient stability of WF connected to power system. • The control strategy depends on a PWM VSC and DC–DC converter. • The effectiveness of proposed controller is compared with PI controller. • The validity of the proposed system is verified by simulation results. - Abstract: This paper presents a novel adaptive artificial neural network (ANN)-controlled superconducting magnetic energy storage (SMES) system to enhance the transient stability of wind farms connected to a multi-machine power system during network disturbances. The control strategy of SMES depends mainly on a sinusoidal pulse width modulation (PWM) voltage source converter (VSC) and an adaptive ANN-controlled DC–DC converter using insulated gate bipolar transistors (IGBTs). The effectiveness of the proposed adaptive ANN-controlled SMES is then compared with that of proportional-integral (PI)-controlled SMES optimized by response surface methodology and genetic algorithm (RSM–GA) considering both of symmetrical and unsymmetrical faults. For realistic responses, real wind speed data and two-mass drive train model of wind turbine generator system is considered in the analyses. The validity of the proposed system is verified by the simulation results which are performed using the laboratory standard dynamic power system simulator PSCAD/EMTDC. Notably, the proposed adaptive ANN-controlled SMES enhances the transient stability of wind farms connected to a multi-machine power system

  9. Overcooling transient selection and thermal hydraulic analyses of the Loviisa PTS assessments

    Energy Technology Data Exchange (ETDEWEB)

    Tuomisto, H [IVO Power Engineering Ltd, Vantaa (Finland)

    1997-09-01

    This paper describes transients selection and thermal hydraulic analyses of various PTS assessment studies performed for the pressure vessels of the Loviisa WWER-reactors. Deterministic analyses have been performed in various stages of the PTS studies and they have always made the formal basis for design and licensing of the reactor pressure vessel. The integrated, probabilistic PTS study was carried out to give an overview of the severity of all different PTS sequences, and give a quantitative estimate of the importance of the PTS issues in relation to the overall safety of the plant. Later, the sequences including external flooding of the pressure vessels were added to the PTS assessment. Thermal recovery annealing of the Loviisa 1 reactor pressure vessel took place during refuelling outage in 1996. (author). 10 refs, 4 figs, 3 tabs.

  10. Assessment of Groundwater Susceptibility to Non-Point Source Contaminants Using Three-Dimensional Transient Indexes.

    Science.gov (United States)

    Zhang, Yong; Weissmann, Gary S; Fogg, Graham E; Lu, Bingqing; Sun, HongGuang; Zheng, Chunmiao

    2018-06-05

    Groundwater susceptibility to non-point source contamination is typically quantified by stable indexes, while groundwater quality evolution (or deterioration globally) can be a long-term process that may last for decades and exhibit strong temporal variations. This study proposes a three-dimensional (3- d ), transient index map built upon physical models to characterize the complete temporal evolution of deep aquifer susceptibility. For illustration purposes, the previous travel time probability density (BTTPD) approach is extended to assess the 3- d deep groundwater susceptibility to non-point source contamination within a sequence stratigraphic framework observed in the Kings River fluvial fan (KRFF) aquifer. The BTTPD, which represents complete age distributions underlying a single groundwater sample in a regional-scale aquifer, is used as a quantitative, transient measure of aquifer susceptibility. The resultant 3- d imaging of susceptibility using the simulated BTTPDs in KRFF reveals the strong influence of regional-scale heterogeneity on susceptibility. The regional-scale incised-valley fill deposits increase the susceptibility of aquifers by enhancing rapid downward solute movement and displaying relatively narrow and young age distributions. In contrast, the regional-scale sequence-boundary paleosols within the open-fan deposits "protect" deep aquifers by slowing downward solute movement and displaying a relatively broad and old age distribution. Further comparison of the simulated susceptibility index maps to known contaminant distributions shows that these maps are generally consistent with the high concentration and quick evolution of 1,2-dibromo-3-chloropropane (DBCP) in groundwater around the incised-valley fill since the 1970s'. This application demonstrates that the BTTPDs can be used as quantitative and transient measures of deep aquifer susceptibility to non-point source contamination.

  11. Transient ischaemic attacks clinics provide equivalent and more efficient care than early in-hospital assessment.

    Science.gov (United States)

    Martínez-Martínez, M M; Martínez-Sánchez, P; Fuentes, B; Cazorla-García, R; Ruiz-Ares, G; Correas-Callero, E; Lara-Lara, M; Díez-Tejedor, E

    2013-02-01

    Clinics for early management of transient ischaemic attacks (TIAs) have been developed in some stroke centres, resulting in reduced recurrence rates compared to appointment-based outpatient management, thus saving on hospitalization. We analysed the care process, recurrence rates and economic impact of the first year of work in our early-management TIA clinic and compared these with our previous in-hospital study protocols for low- and moderate-risk TIA patients. This was a prospective evaluation of the management of low- to moderate-risk TIA patients, comparing a new TIA clinic model (2010) with a previous hospitalization model (2009). Demographic data, vascular risk factor profiles, diagnostic test performance, secondary prevention measures, final aetiological diagnoses and cerebrovascular recurrences at 7 and 90 days were compared between in-hospital and TIA clinic assessed patients. We also carried out an economic comparison of the costs of each model's process. Two hundred and eleven low- to moderate-risk TIA patients were included, of whom 40.8% were hospitalized. There were no differences between the TIA clinic assessed and in-hospital assessed patients in terms of risk factor diagnosis and secondary prevention measures. The stroke recurrence rate (2.4% vs. 1.2%; P = 0.65) was low and similar for both groups (CI 95%, 0.214-20.436; P = 0.52). Cost per patient was €393.28 for clinic versus €1931.18 for in-hospital management. Outpatient management resulted in a 77.8% reduction in hospitalizations. Transient ischaemic attacks clinics are efficient for the early management of low- to moderate-risk TIA patients compared to in-hospital assessment, with no higher recurrence rates and at almost one-fifth the cost. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  12. Title Qualitative stability assessment of cut slopes along the national ...

    Indian Academy of Sciences (India)

    64

    Qualitative stability assessment of cut slopes along the national highway- 05 around Jhakri area, .... The rock types in the area are augen migmatite, biotite gneiss, quartz ..... slopes using quantified method (Sonmez and Ulusay 1999, 2002). Finally a .... through numerical simulation is suggested by many researchers. 1. 2. 3.

  13. Graphical assessment of yield stability and adaptation in cowpeas ...

    African Journals Online (AJOL)

    Graphical assessment of yield stability and adaptation in cowpeas (Vigna unguiculata (L) Walp). DK Ojo, MS Oduola, OA Oduwaye. Abstract. No Abstract. Nigerian Journal of Genetics Vol. 20 2006: pp. 17-25. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  14. The Self-esteem Stability Scale (SESS) for Cross-Sectional Direct Assessment of Self-esteem Stability

    OpenAIRE

    Tobias Altmann; Marcus Roth

    2018-01-01

    Self-esteem stability describes fluctuations in the level of self-esteem experienced by individuals over a brief period of time. In recent decades, self-esteem stability has repeatedly been shown to be an important variable affecting psychological functioning. However, measures of self-esteem stability are few and lacking in validity. In this paper, we present the Self-Esteem Stability Scale (SESS), a unidimensional and very brief scale to directly assess self-esteem stability. In four studie...

  15. Stability Assessment as a Criterion of Stabilization of the Movement Trajectory of Mobile Crane Working Elements

    Science.gov (United States)

    Kacalak, W.; Budniak, Z.; Majewski, M.

    2018-02-01

    The article presents a stability assessment method of the mobile crane handling system based on the safety indicator values that were accepted as the trajectory optimization criterion. With the use of the mathematical model built and the model built in the integrated CAD/CAE environment, analyses were conducted of the displacements of the mass centre of the crane system, reactions of the outrigger system, stabilizing and overturning torques that act on the crane as well as the safety indicator values for the given movement trajectories of the crane working elements.

  16. Improved assessment of outcomes following transient global cerebral ischemia in mice

    DEFF Research Database (Denmark)

    Spray, Stine; Edvinsson, Lars

    2016-01-01

    by limited neurological assessment protocols and present insufficient reporting of the cumulative survival rate. Therefore, we aim at developing a reproducible and easily implementable model of transient GCI in mice with minimal impact on normal mouse behavior. GCI was induced in male C57BL/6 mice......Mouse models of global cerebral ischemia (GCI) allow experimental examination of cerebral pathophysiology in genetically modified mice and fast screening of new treatment strategies. Various surgical protocols of GCI-induction in mice have been published; however, many of these studies are hindered...... and again daily for up to 7 days after GCI or sham operation and was found to be significantly decreased 1-7 days after GCI compared to sham. Furthermore, we found delayed neuronal cell death in the frontal cortex and hippocampus 5 and 7 days after GCI but not at day 3 or after sham operation. The survival...

  17. Assessing resistance of stabilized corrosion resistant steels to intergranular corrosion

    International Nuclear Information System (INIS)

    Karas, A.; Cihal, V. Jr.; Vanek, V.; Herzan, J.; Protiva, K.; Cihal, V.

    1987-01-01

    Resistance to intergranular corrosion was determined for four types of titanium-stabilized steels from the coefficients of stabilization efficiency according to the degree the chemical composition was known. The ATA SUPER steel showed the highest resistance parameter value. The resistance of this type of steel of a specific composition, showing a relatively low value of mean nitrogen content was compared with steel of an optimized chemical composition and with low-carbon niobium stabilized, molybdenum modified steels. The comparison showed guarantees of a sufficient resistance of the steel to intergranular corrosion. The method of assessing the resistance to intergranular corrosion using the calculation of the minimum content of Cr', i.e., the effective chromium content, and the maximum effective carbon content C' giving the resistance parameter k seems to be prospective for practical use in the production of corrosion resistant steels. (author). 1 tab., 5 figs., 15 refs

  18. Development of a hardware-based AC microgrid for AC stability assessment

    Science.gov (United States)

    Swanson, Robert R.

    As more power electronic-based devices enable the development of high-bandwidth AC microgrids, the topic of microgrid power distribution stability has become of increased interest. Recently, researchers have proposed a relatively straightforward method to assess the stability of AC systems based upon the time-constants of sources, the net bus capacitance, and the rate limits of sources. In this research, a focus has been to develop a hardware test system to evaluate AC system stability. As a first step, a time domain model of a two converter microgrid was established in which a three phase inverter acts as a power source and an active rectifier serves as an adjustable constant power AC load. The constant power load can be utilized to create rapid power flow transients to the generating system. As a second step, the inverter and active rectifier were designed using a Smart Power Module IGBT for switching and an embedded microcontroller as a processor for algorithm implementation. The inverter and active rectifier were designed to operate simultaneously using a synchronization signal to ensure each respective local controller operates in a common reference frame. Finally, the physical system was created and initial testing performed to validate the hardware functionality as a variable amplitude and variable frequency AC system.

  19. Synchrophasor-Based Online Coherency Identification in Voltage Stability Assessment

    Directory of Open Access Journals (Sweden)

    ADEWOLE, A. C.

    2015-11-01

    Full Text Available This paper presents and investigates a new measurement-based approach in the identification of coherent groups in load buses and synchronous generators for voltage stability assessment application in large interconnected power systems. A hybrid Calinski-Harabasz criterion and k-means clustering algorithm is developed for the determination of the cluster groups in the system. The proposed method is successfully validated by using the New England 39-bus test system. Also, the performance of the voltage stability assessment algorithm using wide area synchrophasor measurements from the key synchronous generator in each respective cluster was tested online for the prediction of the system's margin to voltage collapse using a testbed comprising of a Programmable Logic Controller (PLC in a hardware-in-the-loop configuration with the Real-Time Digital Simulator (RTDS and Phasor Measurement Units (PMUs.

  20. Quality assessment of digested sludges produced by advanced stabilization processes.

    Science.gov (United States)

    Braguglia, C M; Coors, A; Gallipoli, A; Gianico, A; Guillon, E; Kunkel, U; Mascolo, G; Richter, E; Ternes, T A; Tomei, M C; Mininni, G

    2015-05-01

    The European Union (EU) Project Routes aimed to discover new routes in sludge stabilization treatments leading to high-quality digested sludge, suitable for land application. In order to investigate the impact of different enhanced sludge stabilization processes such as (a) thermophilic digestion integrated with thermal hydrolysis pretreatment (TT), (b) sonication before mesophilic/thermophilic digestion (UMT), and (c) sequential anaerobic/aerobic digestion (AA) on digested sludge quality, a broad class of conventional and emerging organic micropollutants as well as ecotoxicity was analyzed, extending the assessment beyond the parameters typically considered (i.e., stability index and heavy metals). The stability index was improved by adding aerobic posttreatment or by operating dual-stage process but not by pretreatment integration. Filterability was worsened by thermophilic digestion, either alone (TT) or coupled with mesophilic digestion (UMT). The concentrations of heavy metals, present in ranking order Zn > Cu > Pb > Cr ~ Ni > Cd > Hg, were always below the current legal requirements for use on land and were not removed during the processes. Removals of conventional and emerging organic pollutants were greatly enhanced by performing double-stage digestion (UMT and AA treatment) compared to a single-stage process as TT; the same trend was found as regards toxicity reduction. Overall, all the digested sludges exhibited toxicity to the soil bacterium Arthrobacter globiformis at concentrations about factor 100 higher than the usual application rate of sludge to soil in Europe. For earthworms, a safety margin of factor 30 was generally achieved for all the digested samples.

  1. Time course of regional myocardial glucose metabolism after transient ischemia assessed by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Hoshizaki, Hiroshi (Gunma Univ., Maebashi (Japan). School of Medicine)

    1992-11-01

    The purpose of this study was to examine the significance of glucose metabolism in ischemic canine myocardium after reperfusion. Transient ischemia was induced by 90 or 180 minutes occlusion of the left anterior descending coronary artery. Twelve hours and 4 weeks after reperfusion, myocardial blood flow (MBF) and glucose metabolism were assessed (with H[sub 2][sup 15]O and [sup 18]F-FDG, respectively) by positron emission tomography (PET) under the fasting state, and the metabolic findings were compared with the histologic examination. Glucose metabolism in ischemic regions was inversely related to the amount of tissue necrosis 12 hours and 4 weeks after reperfusion (r=-0.89 and r=-0.82, respectively). The perfusion-metabolism mismatch pattern was seen in the area with less than 10 percent necrosis 12 hours after reperfusion, but this pattern disappeared after 4 weeks. The area with 10 to 50 percent necrosis showed the mismatch pattern until 4 weeks after reperfusion, and in the area with more than 50 percent necrosis, perfusion-metabolism concordantly decreased. Thus, metabolic index assessed early after reperfusion by PET identified myocardial viability, and the perfusion-metabolism mismatch pattern sustained in relation to the degree of ischemic injury. Since some regions estimated to be irreversible by PET were viable by the histologic examination, PET study might underestimate the myocardial viability. (author).

  2. Assessing slope stability in unplanned settlements in developing countries.

    Science.gov (United States)

    Anderson, Malcolm G; Holcombe, Liz; Renaud, Jean-Philippe

    2007-10-01

    Unplanned housing in developing countries is often located on steep slopes. Frequently no building code is enforced for such housing and mains water is provided with no drainage provision. Both of these factors can be particularly significant in terms of landslide risk if, as is so often the case, such slopes lack any planned drainage provision. There is thus a need to develop a model that facilitates the assessment of slope stability in an holistic context, incorporating a wide range of factors (including surface cover, soil water topographic convergence, slope loading and point source water leakage) in order that appropriate advice can be given as to the general controls on slope stability in such circumstances. This paper outlines a model configured for this specific purpose and describes an application to a site in St. Lucia, West Indies, where there is active slope movement in an unplanned housing development on relatively steep topography. The model findings are in accord with the nature of the current failure at the site, provide guidance as to the significance of slope drainage and correspond to inferences drawn from an application of resistance envelope methods to the site. In being able to scenario test a uniquely wide range of combinations of factors, the model structure is shown to be highly valuable in assessing dominant slope stability process controls in such complex environments.

  3. Electromechanical impedance method to assess dental implant stability

    International Nuclear Information System (INIS)

    Tabrizi, Aydin; Rizzo, Piervincenzo; Ochs, Mark W

    2012-01-01

    The stability of a dental implant is a prerequisite for supporting a load-bearing prosthesis and establishment of a functional bone–implant system. Reliable and noninvasive methods able to assess the bone interface of dental and orthopedic implants (osseointegration) are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, we propose the electromechanical impedance method as a novel approach for the assessment of dental implant stability. Nobel Biocare ® implants with a size of 4.3 mm diameter ×13 mm length were placed inside bovine bones that were then immersed in a solution of nitric acid to allow material degradation. The degradation simulated the inverse process of bone healing. The implant–bone systems were monitored by bonding a piezoceramic transducer (PZT) to the implants’ abutment and measuring the admittance of the PZT over time. It was found that the PZT’s admittance and the statistical features associated with its analysis are sensitive to the degradation of the bones and can be correlated to the loss of calcium measured by means of the atomic absorption spectroscopy method. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of dental implant stability and integrity. (paper)

  4. Supersonic transient magnetic resonance elastography for quantitative assessment of tissue elasticity.

    Science.gov (United States)

    Liu, Yu; Liu, Jingfei; Fite, Brett Z; Foiret, Josquin; Ilovitsh, Asaf; Leach, J Kent; Dumont, Erik; Caskey, Charles F; Ferrara, Katherine W

    2017-05-21

    Non-invasive, quantitative methods to assess the properties of biological tissues are needed for many therapeutic and tissue engineering applications. Magnetic resonance elastography (MRE) has historically relied on external vibration to generate periodic shear waves. In order to focally assess a biomaterial or to monitor the response to ablative therapy, the interrogation of a specific region of interest by a focused beam is desirable and transient MRE (t-MRE) techniques have previously been developed to accomplish this goal. Also, strategies employing a series of discrete ultrasound pulses directed to increasing depths along a single line-of-sight have been designed to generate a quasi-planar shear wave. Such 'supersonic' excitations have been applied for ultrasound elasticity measurements. The resulting shear wave is higher in amplitude than that generated from a single excitation and the properties of the media are simply visualized and quantified due to the quasi-planar wave geometry and the opportunity to generate the wave at the site of interest. Here for the first time, we extend the application of supersonic methods by developing a protocol for supersonic transient magnetic resonance elastography (sst-MRE) using an MR-guided focused ultrasound system capable of therapeutic ablation. We apply the new protocol to quantify tissue elasticity in vitro using biologically-relevant inclusions and tissue-mimicking phantoms, compare the results with elasticity maps acquired with ultrasound shear wave elasticity imaging (US-SWEI), and validate both methods with mechanical testing. We found that a modified time-of-flight (TOF) method efficiently quantified shear modulus from sst-MRE data, and both the TOF and local inversion methods result in similar maps based on US-SWEI. With a three-pulse excitation, the proposed sst-MRE protocol was capable of visualizing quasi-planar shear waves propagating away from the excitation location and detecting differences in shear

  5. Supersonic transient magnetic resonance elastography for quantitative assessment of tissue elasticity

    Science.gov (United States)

    Liu, Yu; Liu, Jingfei; Fite, Brett Z.; Foiret, Josquin; Ilovitsh, Asaf; Leach, J. Kent; Dumont, Erik; Caskey, Charles F.; Ferrara, Katherine W.

    2017-05-01

    Non-invasive, quantitative methods to assess the properties of biological tissues are needed for many therapeutic and tissue engineering applications. Magnetic resonance elastography (MRE) has historically relied on external vibration to generate periodic shear waves. In order to focally assess a biomaterial or to monitor the response to ablative therapy, the interrogation of a specific region of interest by a focused beam is desirable and transient MRE (t-MRE) techniques have previously been developed to accomplish this goal. Also, strategies employing a series of discrete ultrasound pulses directed to increasing depths along a single line-of-sight have been designed to generate a quasi-planar shear wave. Such ‘supersonic’ excitations have been applied for ultrasound elasticity measurements. The resulting shear wave is higher in amplitude than that generated from a single excitation and the properties of the media are simply visualized and quantified due to the quasi-planar wave geometry and the opportunity to generate the wave at the site of interest. Here for the first time, we extend the application of supersonic methods by developing a protocol for supersonic transient magnetic resonance elastography (sst-MRE) using an MR-guided focused ultrasound system capable of therapeutic ablation. We apply the new protocol to quantify tissue elasticity in vitro using biologically-relevant inclusions and tissue-mimicking phantoms, compare the results with elasticity maps acquired with ultrasound shear wave elasticity imaging (US-SWEI), and validate both methods with mechanical testing. We found that a modified time-of-flight (TOF) method efficiently quantified shear modulus from sst-MRE data, and both the TOF and local inversion methods result in similar maps based on US-SWEI. With a three-pulse excitation, the proposed sst-MRE protocol was capable of visualizing quasi-planar shear waves propagating away from the excitation location and detecting differences in shear

  6. Comparative study of probabilistic methodologies for small signal stability assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rueda, J.L.; Colome, D.G. [Universidad Nacional de San Juan (IEE-UNSJ), San Juan (Argentina). Inst. de Energia Electrica], Emails: joseluisrt@iee.unsj.edu.ar, colome@iee.unsj.edu.ar

    2009-07-01

    Traditional deterministic approaches for small signal stability assessment (SSSA) are unable to properly reflect the existing uncertainties in real power systems. Hence, the probabilistic analysis of small signal stability (SSS) is attracting more attention by power system engineers. This paper discusses and compares two probabilistic methodologies for SSSA, which are based on the two point estimation method and the so-called Monte Carlo method, respectively. The comparisons are based on the results obtained for several power systems of different sizes and with different SSS performance. It is demonstrated that although with an analytical approach the amount of computation of probabilistic SSSA can be reduced, the different degrees of approximations that are adopted, lead to deceptive results. Conversely, Monte Carlo based probabilistic SSSA can be carried out with reasonable computational effort while holding satisfactory estimation precision. (author)

  7. Determination of equivalent mixing height and atmospheric stability assessment

    International Nuclear Information System (INIS)

    Simon, J.; Bulko, M.; Holy, K.

    2007-01-01

    Atmospheric stability is an indicator that reflects the intensity of boundary layer mixing processes. This feature of the atmosphere is especially important since it defines dispersive atmospheric conditions and provides information on how effectively the anthropogenic pollution will be transferred to the higher levels of the atmosphere. The assessment of atmospheric dispersiveness plays a crucial role in the protection of air quality and public health in big cities. The presented paper deals with determination of atmospheric stability via so called Equivalent Mixing Height (EMH) quantity using a radioactive noble gas 222 Rn. A method of deriving a link between 222 Rn activity concentration, eddy diffusion coefficient and EMH using fluid mechanics is also outlined in this work. (authors)

  8. Assessment of light stability of drugs in blood and plasma.

    Science.gov (United States)

    de Vries, Ronald; Diels, Luc; Dillen, Lieve; Sips, Luc; Van Roosbroek, Dirk; Verhaeghe, Tom; Timmerman, Philip

    2016-10-01

    A procedure was developed for the assessment of photochemical stability of drugs in blood and plasma under standardized conditions. The procedure avoids a variable outcome of photochemical stability experiments and tests relevant worst case conditions so that unnecessary light protection is avoided. Results/methodology: Blood and plasma were spiked with a mixture of drugs and incubated in a Suntest CPS(+), in the laboratory on the bench and near the window on a sunny summer day. The results were compared. No protection from light, limited protection from light and full protection from light are advised for drugs that are stable in plasma in the Suntest CPS(+) at 250 W/m(2) for at least 30 min, for 5-30 min and for <5 min, respectively.

  9. Assessment of RELAP5/MOD2 against a main feedwater turbopump trip transient in the Vandellos II Nuclear Power Plant

    International Nuclear Information System (INIS)

    Llopis, C.; Casals, A.; Perez, J.; Mendizabal, R.

    1993-12-01

    The Consejo de Seguridad Nuclear (CSN) and the Asociacion Nuclear Vandellos (ANV) have developed a model of Vandellos II Nuclear Power Plant. The ANV collaboration consisted in the supply of design and actual data, the cooperation in the simulation of the control systems and other model components, as well as in the results analysis. The obtained model has been assessed against the following transients occurred in plant: A trip from the 100% power level (CSN); a load rejection from 100% to 50% (CSN); a load rejection from 75% to 65% (ANV); and, a feedwater turbopump trip (ANV). This copy is a report of the feedwater turbopump trip transient simulation. This transient actually occurred in the plant on June 19, 1989

  10. Impacts Analyses Supporting the National Environmental Policy Act Environmental Assessment for the Resumption of Transient Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Annette L. Schafer; Lloyd C. Brown; David C. Carathers; Boyd D. Christensen; James J. Dahl; Mark L. Miller; Cathy Ottinger Farnum; Steven Peterson; A. Jeffrey Sondrup; Peter V. Subaiya; Daniel M. Wachs; Ruth F. Weiner

    2013-11-01

    Environmental and health impacts are presented for activities associated with transient testing of nuclear fuel and material using two candidate test reactors. Transient testing involves irradiation of nuclear fuel or materials for short time-periods under high neutron flux rates. The transient testing process includes transportation of nuclear fuel or materials inside a robust shipping cask to a hot cell, removal from the shipping cask, pre-irradiation examination of the nuclear materials, assembly of an experiment assembly, transportation of the experiment assembly to the test reactor, irradiation in the test reactor, transport back to the hot cell, and post-irradiation examination of the nuclear fuel or material. The potential for environmental or health consequences during the transportation, examination, and irradiation actions are assessed for normal operations, off-normal (accident) scenarios, and transportation. Impacts to the environment (air, soil, and groundwater), are assessed during each phase of the transient testing process. This report documents the evaluation of potential consequences to the general public. This document supports the Environmental Assessment (EA) required by the U.S. National Environmental Policy Act (NEPA) (42 USC Subsection 4321 et seq.).

  11. Vermicomposting of Food Waste: Assessing the Stability and Maturity

    Directory of Open Access Journals (Sweden)

    Monireh Majlessi

    2012-12-01

    Full Text Available The vermicompost using earthworms (Eisenia Fetida was produced from food waste and chemical parameters (EC, pH, carbon to nitrogen contents(C/N and germination bioassaywas examined in order to assess the stability and maturity indicators during the vermicomposting process. The seed used in the germination bioassay was cress.The ranges of EC,pH, C/N and germination index were 7.5-4.9 mS/cm, 5.6-7.53, 30.13-14.32% and 12.8- 58.4%, espectively. The germination index (GI value revealed that vermicompost rendered as moderate phytotoxic to cress seed.Pearson correlation coefficient was used to evaluate the relationship between the parameters. High statistically significant correlation coefficient was calculated between the GI value and EC in the vermicompost at the 99% confidence level.The C/N value showed that the vermicompost was stable. As a result of these observations, stability test alone, was not able to ensure high vermicompost quality. Therefore, it appears that determining vermicompost quality requires a simultaneous use of maturity and stability tests.

  12. Assessment of Liver Stiffness in Pediatric Fontan Patients Using Transient Elastography

    Directory of Open Access Journals (Sweden)

    Becky Chen

    2016-01-01

    Full Text Available Background. Hepatic fibrosis is a potential complication following Fontan surgery and heralds long-term risk for cirrhosis. Transient elastography (TE is a rapid, noninvasive method to assess liver fibrosis by measuring liver stiffness. Objectives. To compare liver stiffness and liver biochemistries in pediatric Fontan patients with age- and sex-matched controls and to determine patients’ acceptance of TE. Methods. Patients were recruited from British Columbia Children’s Hospital. Twenty-two Fontan patients (15 males were identified. Demographic information and cardiac data were collected. TE was measured using size-appropriate probes. Results. The median age of the Fontan cohort was 13.7 (5.9–16.8 years. Time from Fontan surgery to TE was 9.6 (1.0–12.9 years. The median Fontan circuit pressure was 13 (11–14 mmHg. TE values were higher in Fontan patients versus controls (18.6 versus 4.7 kPa, p<0.001. There was no association between TE values and patient age (r=0.41, p=0.058, time since Fontan surgery (r=0.40, p=0.062, or median Fontan circuit pressure (CVP (r=0.35, p=0.111. Patients found TE to be nonpainful, convenient, and safe. Conclusions. TE is feasible to assess liver stiffness in children following Fontan surgery. Pediatric Fontan patients have markedly elevated liver stiffness values. TE may have important utility in liver care follow-up of pediatric Fontan patients.

  13. Methods to assess the stability of a bicycle rider system

    NARCIS (Netherlands)

    Cooke, A.G.; Bulsink, Vera Elisabeth; Beusenberg, Mark; Dubbeldam, Rosemary; Bonnema, Gerrit Maarten; Poelman, Wim; Koopman, Hubertus F.J.M.

    2012-01-01

    The SOFIE (Intelligent Assisted Bicycles) project wishes to create performance and design guidelines for mechatronic appliances which improve the stability of electric bicycles, so-called intelligent stability assist devices (IAD). To achieve this goal, a stability hypothesis, an advanced

  14. Impact Assessment of Various Methods for Control of Synchronous Generator Excitation on Quality of Transient Processes

    Directory of Open Access Journals (Sweden)

    Y. D. Filipchik

    2011-01-01

    Full Text Available The paper considers an impact of various methods for control of an exciting current pertaining to a synchronous generator on the nature of transient processes. A control algorithm for the exciting current in relation to changes in sliding and acceleration of a generator rotor has been proposed in the paper. The algorithm makes it possible to improve quality of the transient processes due to reduction of oscillation range concerning as an active power so a δ-angle as well.

  15. Impacts Analyses Supporting the National Environmental Policy Act Environmental Assessment for the Resumption of Transient Testing Program

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, Annette L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Brown, LLoyd C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Carathers, David C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Christensen, Boyd D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Dahl, James J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Miller, Mark L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Farnum, Cathy Ottinger [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Peterson, Steven [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sondrup, A. Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States); Subaiya, Peter V. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Wachs, Daniel M. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Weiner, Ruth F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-02-01

    This document contains the analysis details and summary of analyses conducted to evaluate the environmental impacts for the Resumption of Transient Fuel and Materials Testing Program. It provides an assessment of the impacts for the two action alternatives being evaluated in the environmental assessment. These alternatives are (1) resumption of transient testing using the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory (INL) and (2) conducting transient testing using the Annular Core Research Reactor (ACRR) at Sandia National Laboratory in New Mexico (SNL/NM). Analyses are provided for radiologic emissions, other air emissions, soil contamination, and groundwater contamination that could occur (1) during normal operations, (2) as a result of accidents in one of the facilities, and (3) during transport. It does not include an assessment of the biotic, cultural resources, waste generation, or other impacts that could result from the resumption of transient testing. Analyses were conducted by technical professionals at INL and SNL/NM as noted throughout this report. The analyses are based on bounding radionuclide inventories, with the same inventories used for test materials by both alternatives and different inventories for the TREAT Reactor and ACRR. An upper value on the number of tests was assumed, with a test frequency determined by the realistic turn-around times required between experiments. The estimates provided for impacts during normal operations are based on historical emission rates and projected usage rates; therefore, they are bounding. Estimated doses for members of the public, collocated workers, and facility workers that could be incurred as a result of an accident are very conservative. They do not credit safety systems or administrative procedures (such as evacuation plans or use of personal protective equipment) that could be used to limit worker doses. Doses estimated for transportation are conservative and are based on

  16. Drainage effects on the transient, near-surface hydrologic response of a steep hillslope to rainfall: Implications for slope stability, Edmonds, Washington, USA

    Science.gov (United States)

    Biavati, G.; Godt, J.W.; McKenna, J.P.

    2006-01-01

    Shallow landslides on steep (>25??) hillsides along Puget Sound have resulted in occasional loss of life and costly damage to property during intense or prolonged rainfall. As part of a larger project to assess landslide hazards in the Seattle area, the U.S. Geological Survey instrumented two coastal bluff sites in 2001 to observe the subsurface hydrologic response to rainfall. The instrumentation at one of these sites, near Edmonds, Washington, consists of two rain gauges, two water-content probes that measure volumetric water content at eight depths between 0.2 and 2.0 m, and two tensiometer nests that measure soil-water suction at six depths ranging from 0.2 to 1.5m. Measurements from these instruments are used to test one- and two-dimensional numerical models of infiltration and groundwater flow. Capillary-rise tests, performed in the laboratory on soil sample from the Edmonds site, are used to define the soil hydraulic properties for the wetting process. The field observations of water content and suction show an apparent effect of porosity variation with depth on the hydraulic response to rainfall. Using a range of physical properties consistent with our laboratory and field measurements, we perform sensitivity analyses to investigate the effects of variation in physical and hydraulic properties of the soil on rainfall infiltration, pore-pressure response, and, hence, slope stability. For a two-layer-system in which the hydraulic conductivity of the upper layer is at least 10 times greater than the conductivity of the lower layer, and the infiltration rate is greater than the conductivity of the lower layer, a perched water table forms above the layer boundary potentially destabilizing the upper layer of soil. Two-dimensional modeling results indicate that the addition of a simple trench drain to the same two-layer slope has differing effects on the hydraulic response depending on the initial pressure head conditions. For slope-parallel flow conditions

  17. Drainage effects on the transient, near-surface hydrologic response of a steep hillslope to rainfall: implications for slope stability, Edmonds, Washington, USA

    Directory of Open Access Journals (Sweden)

    G. Biavati

    2006-01-01

    Full Text Available Shallow landslides on steep (>25° hillsides along Puget Sound have resulted in occasional loss of life and costly damage to property during intense or prolonged rainfall. As part of a larger project to assess landslide hazards in the Seattle area, the U.S. Geological Survey instrumented two coastal bluff sites in 2001 to observe the subsurface hydrologic response to rainfall. The instrumentation at one of these sites, near Edmonds, Washington, consists of two rain gauges, two water-content probes that measure volumetric water content at eight depths between 0.2 and 2.0 m, and two tensiometer nests that measure soil-water suction at six depths ranging from 0.2 to 1.5 m. Measurements from these instruments are used to test one- and two-dimensional numerical models of infiltration and groundwater flow. Capillary-rise tests, performed in the laboratory on soil sample from the Edmonds site, are used to define the soil hydraulic properties for the wetting process. The field observations of water content and suction show an apparent effect of porosity variation with depth on the hydraulic response to rainfall. Using a range of physical properties consistent with our laboratory and field measurements, we perform sensitivity analyses to investigate the effects of variation in physical and hydraulic properties of the soil on rainfall infiltration, pore-pressure response, and, hence, slope stability. For a two-layer-system in which the hydraulic conductivity of the upper layer is at least 10 times greater than the conductivity of the lower layer, and the infiltration rate is greater than the conductivity of the lower layer, a perched water table forms above the layer boundary potentially destabilizing the upper layer of soil. Two-dimensional modeling results indicate that the addition of a simple trench drain to the same two-layer slope has differing effects on the hydraulic response depending on the initial pressure head conditions. For slope

  18. Assessment of transient stability of cable based transmission grids with reactive power compensation

    DEFF Research Database (Denmark)

    Foo, Yii; Dall, Laurids; Silva, Filipe Miguel Faria da

    2017-01-01

    Underground transmission cables are gaining popularity due to its applications near cities and aesthetic purpose. For example in Denmark, the transmission power grid is changing significantly as many conventional overhead lines (OHL) are replaced by cables and more is expected over the coming years...... through a series of sensitivity analysis with respect to the cables compensation degree. A separate case of disconnecting the SRs of the faulted line is also carried out. The tendencies are initially observed and explained for smaller systems, Single-Machine Infinite Bus (SMIB) and 9-bus system...

  19. SCANAIR a transient fuel performance code Part two: Assessment of modelling capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Georgenthum, Vincent, E-mail: vincent.georgenthum@irsn.fr; Moal, Alain; Marchand, Olivier

    2014-12-15

    Highlights: • The SCANAIR code is devoted to the study of irradiated fuel rod behaviour during RIA. • The paper deals with the status of the code validation for PWR rods. • During the PCMI stage there is a good agreement between calculations and experiments. • The boiling crisis occurrence is rather well predicted. • The code assessment during the boiling crisis has still to be improved. - Abstract: In the frame of their research programmes on fuel safety, the French Institut de Radioprotection et de Sûreté Nucléaire develops the SCANAIR code devoted to the study of irradiated fuel rod behaviour during reactivity initiated accident. A first paper was focused on detailed modellings and code description. This second paper deals with the status of the code validation for pressurised water reactor rods performed thanks to the available experimental results. About 60 integral tests carried out in CABRI and NSRR experimental reactors and 24 separated tests performed in the PATRICIA facility (devoted to the thermal-hydraulics study) have been recalculated and compared to experimental data. During the first stage of the transient, the pellet clad mechanical interaction phase, there is a good agreement between calculations and experiments: the clad residual elongation and hoop strain of non failed tests but also the failure occurrence and failure enthalpy of failed tests are correctly calculated. After this first stage, the increase of cladding temperature can lead to the Departure from Nucleate Boiling. During the film boiling regime, the clad temperature can reach a very high temperature (>700 °C). If the boiling crisis occurrence is rather well predicted, the calculation of the clad temperature and the clad hoop strain during this stage have still to be improved.

  20. The assessment of RELAP5/MOD2 based on pressurizer transient experiments

    International Nuclear Information System (INIS)

    Xue Hanjun; Tanrikut, A.; Menzel, R.

    1992-03-01

    Two typical experiments have been performed in Chinese test facility under full pressure load corresponding to typical PWRs, 1) dynamic behavior of pressurizer due to relief valve operations (Case-I) is extremely important in transients and accident conditions regarding depressurization of PWR primary system; 2) Outsurge/Insurge operation is one of the transient which is often encountered and experienced in pressurizer systems due to pressure transients in primary system of PWRs. The simulation capability of RELAP5/MOD2 is good in comparison to experimental results. The physical models (such as interface model, stratification model), playing a major role in such simulation, seems to be realistic. The effect of realistic valve modeling in depressurization simulation is extremely important. Sufficient data for relief valve (the dynamic characteristics of valve) play a major role. The time dependent junction model and the trip valve model with a reduced discharge coefficient of 0.2 give better predictions in agreement with the experiment data while the trip valve models with discharge coefficient 1.0 yield overdepressurization. The simulation of outsurge/insurge transient yields satisfactory results. The thermal non-equilibrium model is important with respect to simulation of complicated physical phenomena in outsurge/insurge transient but has a negligible effect upon the depressurization simulation. (orig./HP)

  1. Stability assessment for underground excavations and key construction techniques

    CERN Document Server

    Zhu, Hanhua; Zhao, Yu; Niu, Fusheng

    2017-01-01

    This book examines how the state of underground structures can be determined with the assistance of force, deformation and energy. It then analyzes mechanized shield methods, the New Austrian tunneling method (NATM) and conventional methods from this new perspective. The book gathers a wealth of cases reflecting the experiences of practitioners and administrators alike. Based on statistical and engineering studies of these cases, as well as lab and field experiments, it develops a stability assessment approach incorporating a stable equilibrium, which enables engineers to keep the structure and surrounding rocks safe as long as the stable equilibrium and deformation compliance are maintained. The book illustrates the implementation of the method in various tunneling contexts, including soil-rock mixed strata, tunneling beneath operating roads, underwater tunnels, and tunnel pit excavation. It offers a valuable guide for researchers, designers and engineers, especially those who are seeking to understand the u...

  2. Testing of Method for Assessing of Room Thermal Stability

    Directory of Open Access Journals (Sweden)

    Charvátová Hana

    2017-01-01

    Full Text Available The paper presents the interim results of our research on the developing methodological procedure which could be used for assessment of a thermal stability of buildings with regards to its thermal accumulative parameters. The principle of testing is based on a combination of computer simulation of cooled room model developed in COMSOL Multiphysics software and on theoretical calculations with respect to compliance with valid European and Czech technical standards used in building industry and architecture under conditions obtained by real measurement for the room to be tested. The presented example shows the effect of the heataccumulation properties of the outside wall insulation materials on the course of the cooling room for winter conditions.

  3. TRIGRS - A Fortran Program for Transient Rainfall Infiltration and Grid-Based Regional Slope-Stability Analysis, Version 2.0

    Science.gov (United States)

    Baum, Rex L.; Savage, William Z.; Godt, Jonathan W.

    2008-01-01

    The Transient Rainfall Infiltration and Grid-Based Regional Slope-Stability Model (TRIGRS) is a Fortran program designed for modeling the timing and distribution of shallow, rainfall-induced landslides. The program computes transient pore-pressure changes, and attendant changes in the factor of safety, due to rainfall infiltration. The program models rainfall infiltration, resulting from storms that have durations ranging from hours to a few days, using analytical solutions for partial differential equations that represent one-dimensional, vertical flow in isotropic, homogeneous materials for either saturated or unsaturated conditions. Use of step-function series allows the program to represent variable rainfall input, and a simple runoff routing model allows the user to divert excess water from impervious areas onto more permeable downslope areas. The TRIGRS program uses a simple infinite-slope model to compute factor of safety on a cell-by-cell basis. An approximate formula for effective stress in unsaturated materials aids computation of the factor of safety in unsaturated soils. Horizontal heterogeneity is accounted for by allowing material properties, rainfall, and other input values to vary from cell to cell. This command-line program is used in conjunction with geographic information system (GIS) software to prepare input grids and visualize model results.

  4. Investigation of peeling-ballooning stability prior to transient outbursts accompanying transitions out of H-mode in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Eldon, D., E-mail: deldon@princeton.edu [University of California San Diego, 9500 Gilman Dr., La Jolla, California 92093-0964 (United States); Princeton University, Princeton, New Jersey 08543 (United States); Boivin, R. L.; Groebner, R. J.; Osborne, T. H.; Snyder, P. B.; Turnbull, A. D.; Burrell, K. H. [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States); Tynan, G. R.; Boedo, J. A. [University of California San Diego, 9500 Gilman Dr., La Jolla, California 92093-0964 (United States); Kolemen, E. [Princeton University, Princeton, New Jersey 08543 (United States); Schmitz, L. [University of California Los Angeles, Los Angeles, California 90095-7099 (United States); Wilson, H. R. [University of York, Heslington, York YO10 5DD (United Kingdom)

    2015-05-15

    The H-mode transport barrier allows confinement of roughly twice as much energy as in an L-mode plasma. Termination of H-mode necessarily requires release of this energy, and the timescale of that release is of critical importance for the lifetimes of plasma facing components in next step tokamaks such as ITER. H-L transition sequences in modern tokamaks often begin with a transient outburst which appears to be superficially similar to and has sometimes been referred to as a type-I edge localized mode (ELM). Type-I ELMs have been shown to be consistent with ideal peeling ballooning instability and are characterized by significant (up to ∼50%) reduction of pedestal height on short (∼1 ms) timescales. Knowing whether or not this type of instability is present during H-L back transitions will be important of planning for plasma ramp-down in ITER. This paper presents tests of pre-transition experimental data against ideal peeling-ballooning stability calculations with the ELITE code and supports those results with secondary experiments that together show that the transient associated with the H-L transition is not triggered by the same physics as are type-I ELMs.

  5. A development of the direct Lyapunov method for the analysis of transient stability of a system of synchronous generators based on the determination of non- stable equilibria on a multidimensional sphere

    Directory of Open Access Journals (Sweden)

    A. V. Stepanov

    2014-01-01

    Full Text Available A development of the direct Lyapunov method for the analysis of transient stability of a system of synchronous generators based on the determination of non- stable equilibria on a multidimensional sphere.We consider the problem of transient stability analysis for a system of synchronous generators under the action of strong perturbations. The aim of our work is to develop methods to analyze a transient stability of the system of synchronous generators, which allow getting trustworthy results on reserve transient stability under different perturbations. For the analysis of transient stability, we use the direct Lyapunov method.One of the problems for this method application is to find the Lypunov function that well reflects the properties of a parallel system of synchronous generators. The most reliable results were obtained when the analysis of transient stability was performed with a Lyapunov function of energy type. Another problem for application of the direct Lyapunov method is to determine the critical value of the Lyapunov function, which requires finding the non-stable equilibria of the system. Determination of the non-stable equilibria requires studying the Lyapunov function in a multidimensional space in a neighborhood of a stable equilibrium for the post-breakdown system; this is a complicated non-linear problem.In the paper, we propose a method for determination of the non-stable equilibria on a multidimensional sphere. The method is based on a search of a minimum of the Lyapunov function on a multidimensional sphere the center of which is a stable equilibrium. Our method allows, comparing with the other, e.g., gradient methods, reliable finding a non-stable equilibrium and calculating the critical value. The reliability of our method is proved by numerical experiments. The developed methods and a program realized in a MATLAB package can be recommended for design of a post-breakdown control system of synchronous generators or as a

  6. Characteristics and stability analyses of transient one-dimensional two-phase flow equations and their finite difference approximations

    International Nuclear Information System (INIS)

    Lyczkowski, R.W.; Gidaspow, D.; Solbrig, C.W.; Hughes, E.D.

    1975-01-01

    Equation systems describing one-dimensional, transient, two-phase flow with separate continuity, momentum, and energy equations for each phase are classified by use of the method of characteristics. Little attempt is made to justify the physics of these equations. Many of the equation systems possess complex-valued characteristics and hence, according to well-known mathematical theorems, are not well-posed as initial-value problems (IVPs). Real-valued characteristics are necessary but not sufficient to insure well-posedness. In the absence of lower order source or sink terms (potential type flows), which can affect the well-posedness of IVPs, the complex characteristics associated with these two-phase flow equations imply unbounded exponential growth for disturbances of all wavelengths. Analytical and numerical examples show that the ill-posedness of IVPs for the two-phase flow partial differential equations which possess complex characteristics produce unstable numerical schemes. These unstable numerical schemes can produce apparently stable and even accurate results if the growth rate resulting from the complex characteristics remains small throughout the time span of the numerical experiment or if sufficient numerical damping is present for the increment size used. Other examples show that clearly nonphysical numerical instabilities resulting from the complex characteristics can be produced. These latter types of numerical instabilities are shown to be removed by the addition of physically motivated differential terms which eliminate the complex characteristics. (auth)

  7. The Self-esteem Stability Scale (SESS) for Cross-Sectional Direct Assessment of Self-esteem Stability.

    Science.gov (United States)

    Altmann, Tobias; Roth, Marcus

    2018-01-01

    Self-esteem stability describes fluctuations in the level of self-esteem experienced by individuals over a brief period of time. In recent decades, self-esteem stability has repeatedly been shown to be an important variable affecting psychological functioning. However, measures of self-esteem stability are few and lacking in validity. In this paper, we present the Self-Esteem Stability Scale (SESS), a unidimensional and very brief scale to directly assess self-esteem stability. In four studies (total N = 826), we describe the development of the SESS and present evidence for its validity with respect to individual outcomes (life satisfaction, neuroticism, and vulnerable narcissism) and dyadic outcomes (relationship satisfaction in self- and partner ratings) through direct comparisons with existing measures. The new SESS proved to be a stronger predictor than the existing scales and had incremental validity over and above self-esteem level. The results also showed that all cross-sectional measures of self-esteem stability were only moderately associated with variability in self-esteem levels assessed longitudinally with multiple administrations of the Rosenberg Self-Esteem Scale. We discuss this validity issue, arguing that direct and indirect assessment approaches measure relevant, yet different aspects of self-esteem stability.

  8. The Self-esteem Stability Scale (SESS for Cross-Sectional Direct Assessment of Self-esteem Stability

    Directory of Open Access Journals (Sweden)

    Tobias Altmann

    2018-02-01

    Full Text Available Self-esteem stability describes fluctuations in the level of self-esteem experienced by individuals over a brief period of time. In recent decades, self-esteem stability has repeatedly been shown to be an important variable affecting psychological functioning. However, measures of self-esteem stability are few and lacking in validity. In this paper, we present the Self-Esteem Stability Scale (SESS, a unidimensional and very brief scale to directly assess self-esteem stability. In four studies (total N = 826, we describe the development of the SESS and present evidence for its validity with respect to individual outcomes (life satisfaction, neuroticism, and vulnerable narcissism and dyadic outcomes (relationship satisfaction in self- and partner ratings through direct comparisons with existing measures. The new SESS proved to be a stronger predictor than the existing scales and had incremental validity over and above self-esteem level. The results also showed that all cross-sectional measures of self-esteem stability were only moderately associated with variability in self-esteem levels assessed longitudinally with multiple administrations of the Rosenberg Self-Esteem Scale. We discuss this validity issue, arguing that direct and indirect assessment approaches measure relevant, yet different aspects of self-esteem stability.

  9. The Self-esteem Stability Scale (SESS) for Cross-Sectional Direct Assessment of Self-esteem Stability

    Science.gov (United States)

    Altmann, Tobias; Roth, Marcus

    2018-01-01

    Self-esteem stability describes fluctuations in the level of self-esteem experienced by individuals over a brief period of time. In recent decades, self-esteem stability has repeatedly been shown to be an important variable affecting psychological functioning. However, measures of self-esteem stability are few and lacking in validity. In this paper, we present the Self-Esteem Stability Scale (SESS), a unidimensional and very brief scale to directly assess self-esteem stability. In four studies (total N = 826), we describe the development of the SESS and present evidence for its validity with respect to individual outcomes (life satisfaction, neuroticism, and vulnerable narcissism) and dyadic outcomes (relationship satisfaction in self- and partner ratings) through direct comparisons with existing measures. The new SESS proved to be a stronger predictor than the existing scales and had incremental validity over and above self-esteem level. The results also showed that all cross-sectional measures of self-esteem stability were only moderately associated with variability in self-esteem levels assessed longitudinally with multiple administrations of the Rosenberg Self-Esteem Scale. We discuss this validity issue, arguing that direct and indirect assessment approaches measure relevant, yet different aspects of self-esteem stability. PMID:29487551

  10. Assessment of the TASS 1-D neutronics model for the westinghouse and ABB-CE type PWR reactivity induced transients

    International Nuclear Information System (INIS)

    Choi, J.D.; Yoon, H.Y.; Um, K.S.; Kim, H.C.; Sim, S.K.

    1997-01-01

    Best estimate transient analysis code, TASS, has been developed for the normal and transient simulation of the Westinghouse and ABB-CE type PWRs. TASS thermal hydraulic model is based on the non-homogeneous, non-equilibrium two-phase continuity, energy and mixture momentum equations with constitutive relations for closure. Core neutronics model employs both the point kinetics and one-dimensional neutron diffusion model. Semi-implicit numerical scheme is used to solve the discretized finite difference equations. TASS one dimensional neutronics core model has been assessed through the reactivity induced transient analyses for the KORI-3, three loop Westinghouse PWR, and Younggwang-3 (YGN-3), two-loop ABB-CE PWR, nuclear power plants currently operating in Korea. The assessment showed that the TASS one dimensional neutronics core model can be applied for the Westinghouse and ABB-CE type PWRs to gain thermal margin which is necessary for a potential use of the high fuel burnup, extended fuel cycle, power upgrading and for the plant life extension

  11. ASSESSING THE GOVERNANCE FOR COMMODITY PRICE STABILIZATION - A RETROSPECTIVE LOOK

    Directory of Open Access Journals (Sweden)

    Pop Larisa Nicoleta

    2015-07-01

    Full Text Available The volatility of commodity prices has become once again a matter of profound and controversial debates for both political and academic spheres worldwide in the framework of the global economy severely distressed by the recent economic turbulences. Although commodity markets were already notorious for their price instability, the events the world economy experienced in the years 2000s offered new connotations to this phenomenon. In the first decade of this millennium, the commodity markets have struggled with high volatility, with prices reaching historical peaks just to crash dramatically some months later and very soon to restart their rise. The significant increase in volatility generated many debates about its triggering factors, the implications in terms of risk exposure of economic actors, but also the need for reconfiguring regulatory policy frameworks. The quest for the most appropriate means to deal with commodity price turbulences has known different stages over the years. Decision makers worldwide have sought alternatives, formulated and tested various mechanisms whose central aim was to mitigate price fluctuations. Governments formulate and implement consistent regulatory policies whose international coordination is a ‘sine qua non’ condition for stabilizing these markets. However, the turbulences on commodity markets often generate policy responses that sometimes exacerbate rather than mitigate the price instability. The purpose of this paper is to assess the subject of governance regarding commodity price stabilization, offering a retrospective look at the mechanisms implemented over the years, with a central focus on the International Commodity Agreements – instruments through which in the previous decades the producer and consumer governments worldwide pursued price stabilization for some key commodities like sugar, coffee, cocoa, tin and natural rubber. After analyzing the effectiveness of the International Agreements and

  12. Improvement of Transient Stability in a Hybrid Power Multi-System Using a Designed NIDC (Novel Intelligent Damping Controller

    Directory of Open Access Journals (Sweden)

    Ting-Chia Ou

    2017-04-01

    Full Text Available This paper endeavors to apply a novel intelligent damping controller (NIDC for the static synchronous compensator (STATCOM to reduce the power fluctuations, voltage support and damping in a hybrid power multi-system. In this paper, we discuss the integration of an offshore wind farm (OWF and a seashore wave power farm (SWPF via a high-voltage, alternating current (HVAC electric power transmission line that connects the STATCOM and the 12-bus hybrid power multi-system. The hybrid multi-system consists of a battery energy storage system (BESS and a micro-turbine generation (MTG. The proposed NIDC consists of a designed proportional–integral–derivative (PID linear controller, an adaptive critic network and a proposed functional link-based novel recurrent fuzzy neural network (FLNRFNN. Test results show that the proposed controller can achieve better damping characteristics and effectively stabilize the network under unstable conditions.

  13. Conceptualization of preferential flow for hillslope stability assessment

    Science.gov (United States)

    Kukemilks, Karlis; Wagner, Jean-Frank; Saks, Tomas; Brunner, Philip

    2018-03-01

    This study uses two approaches to conceptualize preferential flow with the goal to investigate their influence on hillslope stability. Synthetic three-dimensional hydrogeological models using dual-permeability and discrete-fracture conceptualization were subsequently integrated into slope stability simulations. The slope stability simulations reveal significant differences in slope stability depending on the preferential flow conceptualization applied, despite similar small-scale hydrogeological responses of the system. This can be explained by a local-scale increase of pore-water pressures observed in the scenario with discrete fractures. The study illustrates the critical importance of correctly conceptualizing preferential flow for slope stability simulations. It further demonstrates that the combination of the latest generation of physically based hydrogeological models with slope stability simulations allows for improvement to current modeling approaches through more complex consideration of preferential flow paths.

  14. Applying programmatic risk assessment to nuclear materials stabilization R and D planning

    International Nuclear Information System (INIS)

    Kenley, C.R.; Brown-van Hoozer, S.A.

    1997-01-01

    A systems engineering approach to programmatic risk assessment, derived from the aerospace industry, was applied to various stabilization technologies to assess their relative maturity and availability for use in stabilizing nuclear materials. The assessment provided valuable information for trading off available technologies and identified the at-risk technologies that will require close tracking by the Department of Energy (DOE) to mitigate programmatic risks

  15. Assessing fly ash treatment: remediation and stabilization of heavy metals.

    Science.gov (United States)

    Lima, A T; Ottosen, Lisbeth M; Ribeiro, Alexandra B

    2012-03-01

    Fly ashes from Municipal Solid Waste (MSW), straw (ST) and co-combustion of wood (CW) are here analyzed with the intent of reusing them. Two techniques are assessed, a remediation technique and a solidification/stabilization one. The removal of heavy metals from fly ashes through the electrodialytic process (EDR) has been tried out before. The goal of removing heavy metals has always been the reuse of fly ash, for instance in agricultural fields (BEK). The best removal rates are here summarized and some new results have been added. MSW fly ashes are still too hazardous after treatment to even consider application to the soil. ST ash is the only residue that gets concentrations low enough to be reused, but its fertilizing value might be questioned. An alternative reuse for the three ashes is here preliminary tested, the combination of fly ash with mortar. Fly ashes have been substituted by cement fraction or aggregate fraction. Surprisingly, better compressive strengths were obtained by replacing the aggregate fraction. CW ashes presented promising results for the substitution of aggregate in mortar and possibly in concrete. Copyright © 2010 Elsevier Ltd. All rights reserved.

  16. Assessing fly ash treatment: Remediation and stabilization of heavy metals

    KAUST Repository

    Lima, A.T.

    2010-12-17

    Fly ashes from Municipal Solid Waste (MSW), straw (ST) and co-combustion of wood (CW) are here analyzed with the intent of reusing them. Two techniques are assessed, a remediation technique and a solidification/stabilization one. The removal of heavy metals from fly ashes through the electrodialytic process (EDR) has been tried out before. The goal of removing heavy metals has always been the reuse of fly ash, for instance in agricultural fields (BEK). The best removal rates are here summarized and some new results have been added. MSW fly ashes are still too hazardous after treatment to even consider application to the soil. ST ash is the only residue that gets concentrations low enough to be reused, but its fertilizing value might be questioned. An alternative reuse for the three ashes is here preliminary tested, the combination of fly ash with mortar. Fly ashes have been substituted by cement fraction or aggregate fraction. Surprisingly, better compressive strengths were obtained by replacing the aggregate fraction. CW ashes presented promising results for the substitution of aggregate in mortar and possibly in concrete. © 2010 Elsevier Ltd.

  17. Environmental Assessment -- Test Area North pool stabilization project update

    International Nuclear Information System (INIS)

    1997-08-01

    The purpose of this Environmental Assessment (EA) is to update the ''Test Area North Pool Stabilization Project'' EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped from the EA/FONSI issued May 6, 1996. A new drying process was subsequently developed and is analyzed in Section 2.1.2 of this document. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN

  18. Draft environmental assessment -- Test Area North pool stabilization project update

    International Nuclear Information System (INIS)

    1997-06-01

    The purpose of this Environmental Assessment (EA) is to update the ''Test Area North Pool Stabilization Project'' EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped form the Ea/FONSI issued May 6, 1996. The origin and nature of the TMI core debris and the proposed drying process are described and analyzed in detail in this EA. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN

  19. Test Area North Pool Stabilization Project: Environmental assessment

    International Nuclear Information System (INIS)

    1996-05-01

    The Test Area North (TAN) Pool is located within the fenced TAN facility boundaries on the Idaho National Engineering Laboratory (INEL). The TAN pool stores 344 canisters of core debris from the March, 1979, Three Mile Island (TMI) Unit 2 reactor accident; fuel assemblies from Loss-of-Fluid Tests (LOFT); and Government-owned commercial fuel rods and assemblies. The LOFT and government owned commercial fuel rods and assemblies are hereafter referred to collectively as open-quotes commercial fuelsclose quotes except where distinction between the two is important to the analysis. DOE proposes to remove the canisters of TMI core debris and commercial fuels from the TAN Pool and transfer them to the Idaho Chemical Processing Plant (ICPP) for interim dry storage until an alternate storage location other than at the INEL, or a permanent federal spent nuclear fuel (SNF) repository is available. The TAN Pool would be drained and placed in an industrially and radiologically safe condition for refurbishment or eventual decommissioning. This environmental assessment (EA) identifies and evaluates environmental impacts associated with (1) constructing an Interim Storage System (ISS) at ICPP; (2) removing the TMI and commercial fuels from the pool and transporting them to ICPP for placement in an ISS, and (3) draining and stabilizing the TAN Pool. Miscellaneous hardware would be removed and decontaminated or disposed of in the INEL Radioactive Waste Management Complex (RWMC). This EA also describes the environmental consequences of the no action alternative

  20. Assessing fly ash treatment: Remediation and stabilization of heavy metals

    KAUST Repository

    Lima, A.T.; Ottosen, Lisbeth M.; Ribeiro, Alexandra B.

    2010-01-01

    Fly ashes from Municipal Solid Waste (MSW), straw (ST) and co-combustion of wood (CW) are here analyzed with the intent of reusing them. Two techniques are assessed, a remediation technique and a solidification/stabilization one. The removal of heavy metals from fly ashes through the electrodialytic process (EDR) has been tried out before. The goal of removing heavy metals has always been the reuse of fly ash, for instance in agricultural fields (BEK). The best removal rates are here summarized and some new results have been added. MSW fly ashes are still too hazardous after treatment to even consider application to the soil. ST ash is the only residue that gets concentrations low enough to be reused, but its fertilizing value might be questioned. An alternative reuse for the three ashes is here preliminary tested, the combination of fly ash with mortar. Fly ashes have been substituted by cement fraction or aggregate fraction. Surprisingly, better compressive strengths were obtained by replacing the aggregate fraction. CW ashes presented promising results for the substitution of aggregate in mortar and possibly in concrete. © 2010 Elsevier Ltd.

  1. Development and assessment of a sub-channel code applicable for trans-critical transient of SCWR

    International Nuclear Information System (INIS)

    Liu, X.J.; Yang, T.; Cheng, X.

    2013-01-01

    Highlights: • A new sub-channel code COBRA-SC for SCWR is developed. • Pseudo two-phase method is employed to realize trans-critical transient calculation. • Good suitability of COBRA-SC is demonstrated by preliminary assessment. • The calculation results of COBRA-SC agree well with ATHLET code. -- Abstract: In the last few years, extensive R and D activities have been launched covering various aspects of supercritical water-cooled reactor (SCWR), especially the thermal-hydraulic analysis. Sub-channel code plays an indispensable role to predict the detail thermal-hydraulic behavior of the SCWR fuel assembly. This paper develops a new version of sub-channel code COBRA-SC based on the previous COBRA-IV code. The supercritical water property and heat transfer/pressure drop correlations under supercritical pressure are implemented to this code. Moreover, in order to simulate the trans-critical transient (the pressure undergo a decrease from the supercritical pressure to the subcritical pressure), pseudo two-phase method is employed in COBRA-SC code. This work is completed by introduction of a virtual two-phase region near the pseudo-critical line. A smooth transition of void fraction can be realized. In addition, several heat transfer correlations right underneath the critical point are introduced into this code to capture the heat transfer behavior during the trans-critical transient. Some experimental data from simple geometry, e.g. the single tube, small rod bundle, is used to validate and evaluate this new developed COBRA-SC code. The predicted results show a good agreement with the experimental data, demonstrating good feasibility of this code for SCWR condition. A code to code comparison between COBRA-SC and ATHLET for a blowdown transient of a small fuel assembly is also presented and discussed in this paper

  2. Doppler ultrasonography combined with transient elastography improves the non-invasive assessment of fibrosis in patients with chronic liver diseases.

    Science.gov (United States)

    Alempijevic, Tamara; Zec, Simon; Nikolic, Vladimir; Veljkovic, Aleksandar; Stojanovic, Zoran; Matovic, Vera; Milosavljevic, Tomica

    2017-01-31

    Accurate clinical assessment of liver fibrosis is essential and the aim of our study was to compare and combine hemodynamic Doppler ultrasonography, liver stiffness by transient elastography, and non-invasive serum biomarkers with the degree of fibrosis confirmed by liver biopsy, and thereby to determine the value of combining non-invasive method in the prediction significant liver fibrosis. We included 102 patients with chronic liver disease of various etiology. Each patient was evaluated using Doppler ultrasonography measurements of the velocity and flow pattern at portal trunk, hepatic and splenic artery, serum fibrosis biomarkers, and transient elastography. These parameters were then input into a multilayer perceptron artificial neural network with two hidden layers, and used to create models for predicting significant fibrosis. According to METAVIR score, clinically significant fibrosis (≥F2) was detected in 57.8% of patients. A model based only on Doppler parameters (hepatic artery diameter, hepatic artery systolic and diastolic velocity, splenic artery systolic velocity and splenic artery Resistance Index), predicted significant liver fibrosis with a sensitivity and specificity of75.0% and 60.0%. The addition of unrelated non-invasive tests improved the diagnostic accuracy of Doppler examination. The best model for prediction of significant fibrosis was obtained by combining Doppler parameters, non-invasive markers (APRI, ASPRI, and FIB-4) and transient elastography, with a sensitivity and specificity of 88.9% and 100%. Doppler parameters alone predict the presence of ≥F2 fibrosis with fair accuracy. Better prediction rates are achieved by combining Doppler variables with non-invasive markers and liver stiffness by transient elastography.

  3. Direct Drive Synchronous Machine Models for Stability Assessment of Wind Farms

    Energy Technology Data Exchange (ETDEWEB)

    Poeller, Markus; Achilles, Sebastian [DIgSILENT GmbH, Gomaringen (Germany)

    2003-11-01

    The increasing size of wind farms requires power system stability analysis including dynamic wind generator models. For turbines above 1MW doubly-fed induction machines are the most widely used concept. However, especially in Germany, direct-drive wind generators based on converter-driven synchronous generator concepts have reached considerable market penetration. This paper presents converter driven synchronous generator models of various order that can be used for simulating transients and dynamics in a very wide time range.

  4. Initial assessment of the MHD stability of TMX-U

    International Nuclear Information System (INIS)

    Nexsen, W.E.

    1983-01-01

    In its operation to date TMX-U has reached values of beta which, for all except the hot electron beta, are close to the proposal values and has not encountered MHD stability problems. The hot electron beta values are presently limited by gyrotron output power and pulse length as well as ion confinement time. Further exploration of stability awaits full thermal barrier operation

  5. The Problems and Prospects of Rating Assessment of Political Stability

    Directory of Open Access Journals (Sweden)

    Ирина Анатольевна Белоусова

    2015-12-01

    Full Text Available The article is devoted to the analysis of principles of qualitative and quantitative approaches to measurement of political stability. The author gives a detailed analysis of the problems and prospects of ratings and indices as tools of political analysis and measurement of political stability.

  6. The Automated Assessment of Postural Stability: Balance Detection Algorithm.

    Science.gov (United States)

    Napoli, Alessandro; Glass, Stephen M; Tucker, Carole; Obeid, Iyad

    2017-12-01

    Impaired balance is a common indicator of mild traumatic brain injury, concussion and musculoskeletal injury. Given the clinical relevance of such injuries, especially in military settings, it is paramount to develop more accurate and reliable on-field evaluation tools. This work presents the design and implementation of the automated assessment of postural stability (AAPS) system, for on-field evaluations following concussion. The AAPS is a computer system, based on inexpensive off-the-shelf components and custom software, that aims to automatically and reliably evaluate balance deficits, by replicating a known on-field clinical test, namely, the Balance Error Scoring System (BESS). The AAPS main innovation is its balance error detection algorithm that has been designed to acquire data from a Microsoft Kinect ® sensor and convert them into clinically-relevant BESS scores, using the same detection criteria defined by the original BESS test. In order to assess the AAPS balance evaluation capability, a total of 15 healthy subjects (7 male, 8 female) were required to perform the BESS test, while simultaneously being tracked by a Kinect 2.0 sensor and a professional-grade motion capture system (Qualisys AB, Gothenburg, Sweden). High definition videos with BESS trials were scored off-line by three experienced observers for reference scores. AAPS performance was assessed by comparing the AAPS automated scores to those derived by three experienced observers. Our results show that the AAPS error detection algorithm presented here can accurately and precisely detect balance deficits with performance levels that are comparable to those of experienced medical personnel. Specifically, agreement levels between the AAPS algorithm and the human average BESS scores ranging between 87.9% (single-leg on foam) and 99.8% (double-leg on firm ground) were detected. Moreover, statistically significant differences in balance scores were not detected by an ANOVA test with alpha equal to 0

  7. Assessment of the performance of an emergency boration system for anticipated transients without trip faults

    International Nuclear Information System (INIS)

    Rippon, J.P.; Smedley, C.

    1987-01-01

    Computer modeling of the emergency boration system (EBS) proposed for the Sizewell B PWR is described in relation to the investigation of two design basis Anticipated Transients Without Trip faults. The performance of the EBS is shown to be dependent on the assumptions made with regard to mixing of RCS coolant with boric acid solution in the tank. An experimental investigation of mixing is described, the results of which are used to validate the computer modeling. Beneficial effects of the EBS in the faults considered are demonstrated in terms of limiting primary pressure, voiding and increasing the shut-down margin

  8. ROSA-III/971, BWR Rig of Safety Assessment LOCA, Loss of Offsite Power Transient

    International Nuclear Information System (INIS)

    1992-01-01

    1 - Description of test facility: ROSA-III is a 1/124 scaled down test facility with electrically heated core designed to study the response of engineered safety features to loss-of-coolant accidents in in commercial BWR. It consists of the following, fully instrumented subsystems: (a) the pressure vessel with a core simulating four half-length fuel assemblies and control rod; (b) steam line and feed water line, which are independent open loops; (c) coolant recirculation system, which consists of two loops provided with a recirculation pump and two jet pumps in each loop; (d) emergency cooling system, including HPCS, LPCS, LPCI, and ADS. 2 - Description of test: Run 971 simulated a BWR LOSS of off-site power transient. The core scram was assumed to occur at 6 seconds after the transient initiated by the turbine trip. HPCS failure was assumed. After ADS started, the upper half of the core was uncovered by steam. The core was re-flooded by LPCS alone

  9. Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Leslie, William D; Levin, Daniel P; Demeter, Sandor J

    2007-01-01

    Transient arrhythmias can affect transient ischemic dilation (TID) ratios. This study was initiated to evaluate the frequency and effect of normal heart rate change on TID measures in routine clinical practice. Consecutive patients undergoing stress/rest sestamibi gated myocardial perfusion scintigraphy were studied (N = 407). Heart rate at the time of stress and rest imaging were recorded. TID ratios were analyzed in relation to absolute change in heart rate (stress minus rest) for subjects with normal perfusion and systolic function (Group 1, N = 169) and those with abnormalities in perfusion and/or function (Group 2, N = 238). In Group 1, mean TID ratio was inversely correlated with the change in heart rate (r = -0.47, P < 0.0001). For every increase of 10 BPM in heart rate change, the TID ratio decreased by approximately 0.06 (95% confidence interval 0.04–0.07). In Group 2, multiple linear regression demonstrated that the change in heart rate (beta = -0.25, P < 0.0001) and the summed difference score (beta = 0.36, P < 0.0001) were independent predictors of the TID ratio. Normal variation in heart rate between the stress and rest components of myocardial perfusion scans is common and can influence TID ratios in patients with normal and abnormal cardiac scans

  10. New possibilities for slope stability assessment of spoil banks

    Energy Technology Data Exchange (ETDEWEB)

    Radl, A [Palivovy Kombinat, Vresova (Czechoslovakia)

    1991-03-01

    Discusses problems associated with slope stability of spoil banks consisting of sedimentary rocks from brown coal surface mining. Effects of rock physical properties on slope stability are analyzed: grain size distribution, compression strength, moisture content, angle of internal friction, etc. Mechanism of plastic slope deformation which occurs during a landslide is evaluated. Formulae for calculating slope stability considering stress distribution in a spoil bank (including all the main factors that influence stresses) are derived. Practical use of the gamma-gamma logging and logging schemes used in geodetic surveys of unstable spoil banks in Czechoslovakia (the Vintirov spoil bank in the Sokolov brown coal district) are discussed. 5 refs.

  11. Qualitative stability assessment of cut slopes along the National ...

    Indian Academy of Sciences (India)

    Jagadish Kundu

    2017-11-23

    Nov 23, 2017 ... Landslide is the most common hazard in the state. Every year ... table 2. 3. Stability evaluation (qualitative) ..... the slopes using quantified method (Sonmez and ..... Research to Engineering, Proceedings of the 2nd Interna-.

  12. Environmental assessment of different strategies for production of stabilized yeast

    OpenAIRE

    Monclus, Vincent; Pénicaud, Caroline; Perret, Bruno; Fonseca, Fernanda

    2016-01-01

    Yeast are widely used for producing fermented (bread, beer...) and health benefit (probiotics) products. The production of stable and active yeast involves fermentation, concentration, protection, drying (stabilization) and storage. During the stabilization and storage steps, the cells face numerous stress which may deteriorate functional properties and cause cell death. Different strategies can be used to preserve cell survival, such as changing growth medium for fermentation or adapting pro...

  13. Assessment and mapping of slope stability based on slope units: A ...

    Indian Academy of Sciences (India)

    Shallow landslide; infinite slope stability equation; return period precipitation; assessment; slope unit. ... 2010), logistic regression ... model to assess the hazard of shallow landslides ..... grating a fuzzy k-means classification and a Bayesian.

  14. Assessment of the potential for high-pressure melt ejection resulting from a Surry station blackout transient

    International Nuclear Information System (INIS)

    Knudson, D.L.; Dobbe, C.A.

    1993-11-01

    Containment integrity could be challenged by direct heating associated with a high pressure melt ejection (HPME) of core materials following reactor vessel breach during certain severe accidents. Intentional reactor coolant system (RCS) depressurization, where operators latch pressurizer relief valves open, has been proposed as an accident management strategy to reduce risks by mitigating the severity of HPME. However, decay heat levels, valve capacities, and other plant-specific characteristics determine whether the required operator action will be effective. Without operator action, natural circulation flows could heat ex-vessel RCS pressure boundaries (surge line and hot leg piping, steam generator tubes, etc.) to the point of failure before vessel breach, providing an alternate mechanism for RCS depressurization and HPME mitigation. This report contains an assessment of the potential for HPME during a Surry station blackout transient without operator action and without recovery. The assessment included a detailed transient analysis using the SCDAP/RELAP5/MOD3 computer code to calculate the plant response with and without hot leg countercurrent natural circulation, with and without reactor coolant pump seal leakage, and with variations on selected core damage progression parameters. RCS depressurization-related probabilities were also evaluated, primarily based on the code results

  15. Assessing one-dimensional diffusion in nanoporous materials from transient concentration profiles

    International Nuclear Information System (INIS)

    Heinke, Lars; Kaerger, Joerg

    2008-01-01

    The use of interference microscopy has enabled the direct observation of transient concentration profiles generated by intracrystalline transport diffusion in nanoporous materials. The thus accessible intracrystalline concentration profiles contain a wealth of information which cannot be deduced by any macroscopic method. In this paper, we illustrate five different ways for determining the concentration-dependent diffusivity in one-dimensional systems and two for the surface permeability. These methods are discussed by application to concentration profiles evolving during the uptake of methanol by the zeolite ferrierite and of methanol by the metal organic framework (MOF) manganese(II) formate. We show that the diffusivity can be calculated most precisely by means of Fick's 1st law. As the circumstances permit, Boltzmann's integration method also yields very precise results. Furthermore, we present a simple procedure that enables the estimation of the influence of the surface barrier on the overall uptake process by plotting the boundary concentration versus the overall uptake

  16. Assessment of RELAP5/MOD2 code using loss of offsite power transient data of KNU [Korea Nuclear Unit] No. 1 Plant

    International Nuclear Information System (INIS)

    Chung, Bud-Dong; Kim, Hho-Jung

    1990-04-01

    This report presents a code assessment study based on a real plant transient that occurred on June 9, 1981 at the KNU number-sign 1 (Korea Nuclear Unit Number 1). KNU number-sign 1 is a two-loop Westinghouse PWR plant of 587 Mwe. The loss of offsite power transient occurred at the 77.5% reactor power with 0.5%/hr power ramp. The real plant data were collected from available on-line plant records and computer diagnostics. The transient was simulated by RELAP5/MOD2/36.05 and the results were compared with the plant data to assess the code weaknesses and strengths. Some nodalization studies were performed to contribute to developing a guideline for PWR nodalization for the transient analysis. 5 refs., 18 figs., 3 tabs

  17. The application of the Accelerated Stability Assessment Program (ASAP) to quality by design (QbD) for drug product stability.

    Science.gov (United States)

    Waterman, Kenneth Craig

    2011-09-01

    An isoconversion paradigm, where times in different temperature and humidity-controlled stability chambers are set to provide a fixed degradant level, is shown to compensate for the complex, non-single order kinetics of solid drug products. A humidity-corrected Arrhenius equation provides reliable estimates for temperature and relative humidity effects on degradation rates. A statistical protocol is employed to determine best fits for chemical stability data, which in turn allows for accurate estimations of shelf life (with appropriate confidence intervals) at any storage condition including inside packaging (based on the moisture vapor transmission rate of the packaging and moisture sorption isotherms of the internal components). These methodologies provide both faster results and far better predictions of chemical stability limited shelf life (expiry) than previously possible. Precise shelf-life estimations are generally determined using a 2-week, product-specific protocol. Once the model for a product is developed, it can play a critical role in providing the product understanding necessary for a quality by design (QbD) filing for product approval and enable rational control strategies to assure product stability. Moreover, this Accelerated Stability Assessment Program (ASAP) enables the coupling of product attributes (e.g., moisture content, packaging options) to allow for flexibility in how control strategies are implemented to provide a balance of cost, speed, and other factors while maintaining adequate stability.

  18. Assessment of Lightning Transients on a De-Iced Rotor Blade with Predictive Tools and Coaxial Return Measurements

    Science.gov (United States)

    Guillet, S.; Gosmain, A.; Ducoux, W.; Ponçon, M.; Fontaine, G.; Desseix, P.; Perraud, P.

    2012-05-01

    The increasing use of composite materials in aircrafts primary structures has led to different problematics in the field of safety of flight in lightning conditions. The consequences of this technological mutation, which occurs in a parallel context of extension of electrified critical functions, are addressed by aircraft manufacturers through the enhancement of their available assessment means of lightning transient. On the one hand, simulation tools, provided an accurate description of aircraft design, are today valuable assessment tools, in both predictive and operative terms. On the other hand, in-house test means allow confirmation and consolidation of design office hardening solutions. The combined use of predictive simulation tools and in- house test means offers an efficient and reliable support for all aircraft developments in their various life-time stages. The present paper provides PREFACE research project results that illustrate the above introduced strategy on the de-icing system of the NH90 composite main rotor blade.

  19. Damage Stability Assessment of an HSC after Grounding

    DEFF Research Database (Denmark)

    Ravn, Erik Sonne; Simonsen, Bo Cerup; Baatrup, Jan

    2000-01-01

    Currently a substantial effort is done within the International Maritime Organisation (IMO) on revision of the High Speed Craft (HSC) Code. A main issue is the extent of bottom damage and raking damage due to grounding on hard rocks and the corresponding requirements to the damage stability...... of the vessel. It has been found that high-speed craft can experience a damage length up to 100% of the ship length. It has, however, also been argued that the damage stability requirements should reflect the size and probability of the damage with a reduction of the demand for the largest damages.......In the present paper a detailed grounding and damage stability analysis is carried out for two specific HSC, a mono-hull (86 m) and a catamaran (69 m). First various grounding scenarios are considered with different values of the forward speed and ground geometry. The results indicate that 100% bottom damage...

  20. Assessment on the mechanical stability of underground excavations

    International Nuclear Information System (INIS)

    Kuroki, Shigemori; Taniguchi, Wataru; Sugino, Hiroyuki; Koo, Shigeru; Hasegawa, Hiroshi; Kubota, Shigeru; Dewa, Katsuyuki

    1999-11-01

    It is planned to construct the tunnels and emplace waste packages at several hundred meters to 1,000 meters under the ground for the repository of high-level radioactive waste based on a policy to assure the safe life environment. It is required to be mechanically stable for the tunnels to assure the work safety throughout the construction, operation and closure phase. In this report, the mechanical stability of tunnels, that is a factor of design requisites, was evaluated by the analyses to present an outline of the technical reliability of geological disposal. To put it concretely, the tunnel sections were determined to have the required areas and shapes, and the analyses on the mechanical stability at tunnel excavations and earthquake, at tunnel intersections were conducted by the theoretical analysis and finite element method. The results obtained by these investigations are shown below: It will be able to construct the tunnels with present techniques. The mechanical stability of tunnels will be assured if proper supports are given, and adequate tunnel spacing and disposal-pit pitches are set. The mechanical stability will be assured at the tunnel intersections if proper reinforcement measures are taken. The reinforcement will be required for the intersection areas over the distance of 1D (D: diameter of tunnels) on the obtuse angle side, and 4D on the acute angle side, when intersection angle is set at 30 degrees. The investigations were conducted on the assumption that the experienced big earthquake occurred. The results show that the effect of earthquake on the mechanical stability of tunnels is small, and tunnels are stable at the earthquake when the mechanical stability at tunnel excavations is assured. (author)

  1. Techniques for Liquid Rocket Combustion Spontaneous Stability and Rough Combustion Assessments

    Science.gov (United States)

    Kenny, R. J.; Giacomoni, C.; Casiano, M. J.; Fischbach, S. R.

    2016-01-01

    This work presents techniques for liquid rocket engine combustion stability assessments with respect to spontaneous stability and rough combustion. Techniques covering empirical parameter extraction, which were established in prior works, are applied for three additional programs: the F-1 Gas Generator (F1GG) component test program, the RS-84 preburner component test program, and the Marshall Integrated Test Rig (MITR) program. Stability assessment parameters from these programs are compared against prior established spontaneous stability metrics and updates are identified. Also, a procedure for comparing measured with predicted mode shapes is presented, based on an extension of the Modal Assurance Criterion (MAC).

  2. Quantitative Assessment of Interutterance Stability: Application to Dysarthria

    Science.gov (United States)

    Cummins, Fred; Lowit, Anja; van Brenk, Frits

    2014-01-01

    Purpose: Following recent attempts to quantify articulatory impairment in speech, the present study evaluates the usefulness of a novel measure of motor stability to characterize dysarthria. Method: The study included 8 speakers with ataxic dysarthria (AD), 16 speakers with hypokinetic dysarthria (HD) as a result of Parkinson's disease, and…

  3. THE USE OF GEOMORPHOLOGY IN THE ASSESSMENT OF STREAM STABILITY

    Science.gov (United States)

    Various applications of geomorphic data and stream stability rating systems are being considered in order to establish tools for the development of TMDLs for clean sediment in streams. The transport of "clean" sediment, as opposed to contaminated sediment, is of concern to the en...

  4. Assessing the roll stability of heavy vehicles in South Africa

    CSIR Research Space (South Africa)

    Benade, R

    2016-07-01

    Full Text Available of these crashes involve heavy vehicle rollover. The regulations in the National Road Traffic Act of South Africa that govern heavy vehicle design do not directly address the roll stability of heavy vehicles. The internationally accepted method of regulating roll...

  5. Performance assessment of mass flow rate measurement capability in a large scale transient two-phase flow test system

    International Nuclear Information System (INIS)

    Nalezny, C.L.; Chapman, R.L.; Martinell, J.S.; Riordon, R.P.; Solbrig, C.W.

    1979-01-01

    Mass flow is an important measured variable in the Loss-of-Fluid Test (LOFT) Program. Large uncertainties in mass flow measurements in the LOFT piping during LOFT coolant experiments requires instrument testing in a transient two-phase flow loop that simulates the geometry of the LOFT piping. To satisfy this need, a transient two-phase flow loop has been designed and built. The load cell weighing system, which provides reference mass flow measurements, has been analyzed to assess its capability to provide the measurements. The analysis consisted of first performing a thermal-hydraulic analysis using RELAP4 to compute mass inventory and pressure fluctuations in the system and mass flow rate at the instrument location. RELAP4 output was used as input to a structural analysis code SAPIV which is used to determine load cell response. The computed load cell response was then smoothed and differentiated to compute mass flow rate from the system. Comparison between computed mass flow rate at the instrument location and mass flow rate from the system computed from the load cell output was used to evaluate mass flow measurement capability of the load cell weighing system. Results of the analysis indicate that the load cell weighing system will provide reference mass flows more accurately than the instruments now in LOFT

  6. Assessment of Liver Viscoelasticity for the Diagnosis of Early Stage Fatty Liver Disease Using Transient Elastography

    Science.gov (United States)

    Remenieras, Jean-Pierre; Dejobert, Maelle; Bastard, Cécile; Miette, Véronique; Perarnau, Jean-Marc; Patat, Frédéric

    Nonalcoholic fatty liver disease (NAFLD) is characterized by accumulation of fat within the Liver. The main objective of this work is (1) to evaluate the feasibility of measuring in vivo in the liver the shear wave phase velocity dispersion cs(ω) between 20 Hz and 90 Hz using vibration-controlled transient elastography (VCTE); (2) to estimate through the rheological Kelvin-Voigt model the shear elastic μ and shear viscosity η modulus; (3) to correlate the evolution of these viscoelastic parameters on two patients at Tours Hospital with the hepatic fat percentage measured with T1-weighted gradient-echo in-and out-phase MRI sequence. For the first volunteer who has 2% of fat in the liver, we obtained μ = 1233 ± 133 Pa and η = 0.5 ± 0.4 Pa.s. For the patient with 22% of fat, we measure μ = 964 ± 91 Pa and η = 1.77 ± 0.3 Pa.s. In conclusion, this novel method showed to be sensitive in characterizing the visco-elastic properties of fatty liver.

  7. Assessment of stability during gait in patients with spinal deformity-A preliminary analysis using the dynamic stability margin.

    Science.gov (United States)

    Simon, Anne-Laure; Lugade, Vipul; Bernhardt, Kathie; Larson, A Noelle; Kaufman, Kenton

    2017-06-01

    Daily living activities are dynamic, requiring spinal motion through space. Current assessment of spinal deformities is based on static measurements from full-spine standing radiographs. Tools to assess dynamic stability during gait might be useful to enhance the standard evaluation. The aim of this study was to evaluate gait dynamic imbalance in patients with spinal deformity using the dynamic stability margin (DSM). Twelve normal subjects and 17 patients with spinal deformity were prospectively recruited. A kinematic 3D gait analysis was performed for the control group (CG) and the spinal deformity group (SDG). The DSM (distance between the extrapolated center of mass and the base of support) and time-distance parameters were calculated for the right and left side during gait. The relationship between DSM and step length was assessed using three variables: gait stability, symmetry, and consistency. Variables' accuracy was validated by a discriminant analysis. Patients with spinal deformity exhibited gait instability according to the DSM (0.25m versus 0.31m) with decreased velocity (1.1ms -1 versus 1.3ms -1 ) and decreased step length (0.32m versus 0.38m). According to the discriminant analysis, gait stability was the more accurate variable (area under the curve AUC=0.98) followed by gait symmetry and consistency. However, gait consistency showed 100% of specificity, sensitivity, and accuracy of precision. The DSM showed that patients with spinal malalignment exhibit decreased gait stability, symmetry, and consistency besides gait time-distance parameter changes. Additional work is required to determine how to apply the DSM for preoperative and postoperative spinal deformity management. Copyright © 2017. Published by Elsevier B.V.

  8. The utility of the historical record for assessing the transient climate response to cumulative emissions

    Science.gov (United States)

    Friedlingstein, Pierre

    2018-01-01

    The historical observational record offers a way to constrain the relationship between cumulative carbon dioxide emissions and global mean warming. We use a standard detection and attribution technique, along with observational uncertainties to estimate the all-forcing or ‘effective’ transient climate response to cumulative emissions (TCRE) from the observational record. Accounting for observational uncertainty and uncertainty in historical non-CO2 radiative forcing gives a best-estimate from the historical record of 1.84°C/TtC (1.43–2.37°C/TtC 5–95% uncertainty) for the effective TCRE and 1.31°C/TtC (0.88–2.60°C/TtC 5–95% uncertainty) for the CO2-only TCRE. While the best-estimate TCRE lies in the lower half of the IPCC likely range, the high upper bound is associated with the not-ruled-out possibility of a strongly negative aerosol forcing. Earth System Models have a higher effective TCRE range when compared like-for-like with the observations over the historical period, associated in part with a slight underestimate of diagnosed cumulative emissions relative to the observational best-estimate, a larger ensemble mean-simulated CO2-induced warming, and rapid post-2000 non-CO2 warming in some ensemble members. This article is part of the theme issue ‘The Paris Agreement: understanding the physical and social challenges for a warming world of 1.5°C above pre-industrial levels'. PMID:29610381

  9. The utility of the historical record for assessing the transient climate response to cumulative emissions

    Science.gov (United States)

    Millar, Richard J.; Friedlingstein, Pierre

    2018-05-01

    The historical observational record offers a way to constrain the relationship between cumulative carbon dioxide emissions and global mean warming. We use a standard detection and attribution technique, along with observational uncertainties to estimate the all-forcing or `effective' transient climate response to cumulative emissions (TCRE) from the observational record. Accounting for observational uncertainty and uncertainty in historical non-CO2 radiative forcing gives a best-estimate from the historical record of 1.84°C/TtC (1.43-2.37°C/TtC 5-95% uncertainty) for the effective TCRE and 1.31°C/TtC (0.88-2.60°C/TtC 5-95% uncertainty) for the CO2-only TCRE. While the best-estimate TCRE lies in the lower half of the IPCC likely range, the high upper bound is associated with the not-ruled-out possibility of a strongly negative aerosol forcing. Earth System Models have a higher effective TCRE range when compared like-for-like with the observations over the historical period, associated in part with a slight underestimate of diagnosed cumulative emissions relative to the observational best-estimate, a larger ensemble mean-simulated CO2-induced warming, and rapid post-2000 non-CO2 warming in some ensemble members. This article is part of the theme issue `The Paris Agreement: understanding the physical and social challenges for a warming world of 1.5°C above pre-industrial levels'.

  10. Rapid and Objective Assessment of Neural Function in Autism Spectrum Disorder Using Transient Visual Evoked Potentials.

    Directory of Open Access Journals (Sweden)

    Paige M Siper

    Full Text Available There is a critical need to identify biomarkers and objective outcome measures that can be used to understand underlying neural mechanisms in autism spectrum disorder (ASD. Visual evoked potentials (VEPs offer a noninvasive technique to evaluate the functional integrity of neural mechanisms, specifically visual pathways, while probing for disease pathophysiology.Transient VEPs (tVEPs were obtained from 96 unmedicated children, including 37 children with ASD, 36 typically developing (TD children, and 23 unaffected siblings (SIBS. A conventional contrast-reversing checkerboard condition was compared to a novel short-duration condition, which was developed to enable objective data collection from severely affected populations who are often excluded from electroencephalographic (EEG studies.Children with ASD showed significantly smaller amplitudes compared to TD children at two of the earliest critical VEP components, P60-N75 and N75-P100. SIBS showed intermediate responses relative to ASD and TD groups. There were no group differences in response latency. Frequency band analyses indicated significantly weaker responses for the ASD group in bands encompassing gamma-wave activity. Ninety-two percent of children with ASD were able to complete the short-duration condition compared to 68% for the standard condition.The current study establishes the utility of a short-duration tVEP test for use in children at varying levels of functioning and describes neural abnormalities in children with idiopathic ASD. Implications for excitatory/inhibitory balance as well as the potential application of VEP for use in clinical trials are discussed.

  11. Systematic Review of the Exposure Assessment and Epidemiology of High-Frequency Voltage Transients

    Directory of Open Access Journals (Sweden)

    Frank eDe Vocht

    2016-03-01

    Full Text Available Conclusions of epidemiological studies describing adverse health effects as a result of exposure to electromagnetic fields are not unanimous and often contradictory. It has been proposed that an explanation could be that high frequency voltage transients (dirty electricity [DE] which are superimposed on 50/60Hz fields, but are generally not measured, is the real causal agent. DE has been linked to many different health and wellbeing effects, and on the basis of this an industry selling measurement and filtering equipment is growing. We reviewed the available peer-reviewed evidence for DE as a causal agent for adverse human health effects.A literature search was performed in the Cochrane Library, PubMed, Web of Science, Google Scholar and additional publications were obtained from reference lists and from the grey literature. This search resulted in 25 publications; 16 included primary epidemiological and/or exposure data. All studies were reviewed by both authors independently, and including a re-review of studies included in a review of data available up to July 31 2009 by one of the authors. DE has been measured differently in different studies and comparison data are not available. There is no evidence for 50 Graham/Stetzer (G/S units as a safety threshold being anything more than arbitrary. The epidemiological evidence on human health effects of DE is primarily based on, often re-used, case descriptions. Quantitative evidence relies on self-reporting in non-blinded interventions, ecological associations, and one cross-sectional cohort study of cancer risk which does not point to DE as the causal agent. The available evidence for DE as an exposure affecting human health at present does not stand up to scientific scrutiny.

  12. Assessment of oscillatory stability constrained available transfer capability

    International Nuclear Information System (INIS)

    Jain, T.; Singh, S.N.; Srivastava, S.C.

    2009-01-01

    This paper utilizes a bifurcation approach to compute oscillatory stability constrained available transfer capability (ATC) in an electricity market having bilateral as well as multilateral transactions. Oscillatory instability in non-linear systems can be related to Hopf bifurcation. At the Hopf bifurcation, one pair of the critical eigenvalues of the system Jacobian reaches imaginary axis. A new optimization formulation, including Hopf bifurcation conditions, has been developed in this paper to obtain the dynamic ATC. An oscillatory stability based contingency screening index, which takes into account the impact of transactions on severity of contingency, has been utilized to identify critical contingencies to be considered in determining ATC. The proposed method has been applied for dynamic ATC determination on a 39-bus New England system and a practical 75-bus Indian system considering composite static load as well as dynamic load models. (author)

  13. Combustion Stability Assessments of the Black Brant Solid Rocket Motor

    Science.gov (United States)

    Fischbach, Sean

    2014-01-01

    The Black Brant variation of the Standard Brant developed in the 1960's has been a workhorse motor of the NASA Sounding Rocket Project Office (SRPO) since the 1970's. In March 2012, the Black Brant Mk1 used on mission 36.277 experienced combustion instability during a flight at White Sands Missile Range, the third event in the last four years, the first occurring in November, 2009, the second in April 2010. After the 2010 event the program has been increasing the motor's throat diameter post-delivery with the goal of lowering the chamber pressure and increasing the margin against combustion instability. During the most recent combustion instability event, the vibrations exceeded the qualification levels for the Flight Termination System. The present study utilizes data generated from T-burner testing of multiple Black Brant propellants at the Naval Air Warfare Center at China Lake, to improve the combustion stability predictions for the Black Brant Mk1 and to generate new predictions for the Mk2. Three unique one dimensional (1-D) stability models were generated, representing distinct Black Brant flights, two of which experienced instabilities. The individual models allowed for comparison of stability characteristics between various nozzle configurations. A long standing "rule of thumb" states that increased stability margin is gained by increasing the throat diameter. In contradiction to this experience based rule, the analysis shows that little or no margin is gained from a larger throat diameter. The present analysis demonstrates competing effects resulting from an increased throat diameter accompanying a large response function. As is expected, more acoustic energy was expelled through the nozzle, but conversely more acoustic energy was generated due to larger gas velocities near the propellant surfaces.

  14. Assessing Romanian financial sector stability: the importance of the international economic climate

    OpenAIRE

    Albulescu, Claudiu Tiberiu

    2008-01-01

    The aim of this paper is to develop an aggregate stability index for the Romanian financial system. The index which is meant to enhance the set of analysis used by the central bank to assess the financial stability accurately reflects the financial stability dynamics and the periods with financial turbulences during 1997-2007 in Romania. By the application of a technique which enables the measurement of the components’ contribution to the aggregate index volatility, we show that some individu...

  15. Stabilization

    Directory of Open Access Journals (Sweden)

    Muhammad H. Al-Malack

    2016-07-01

    Full Text Available Fuel oil flyash (FFA produced in power and water desalination plants firing crude oils in the Kingdom of Saudi Arabia is being disposed in landfills, which increases the burden on the environment, therefore, FFA utilization must be encouraged. In the current research, the effect of adding FFA on the engineering properties of two indigenous soils, namely sand and marl, was investigated. FFA was added at concentrations of 5%, 10% and 15% to both soils with and without the addition of Portland cement. Mixtures of the stabilized soils were thoroughly evaluated using compaction, California Bearing Ratio (CBR, unconfined compressive strength (USC and durability tests. Results of these tests indicated that stabilized sand mixtures could not attain the ACI strength requirements. However, marl was found to satisfy the ACI strength requirement when only 5% of FFA was added together with 5% of cement. When the FFA was increased to 10% and 15%, the mixture’s strength was found to decrease to values below the ACI requirements. Results of the Toxicity Characteristics Leaching Procedure (TCLP, which was performed on samples that passed the ACI requirements, indicated that FFA must be cautiously used in soil stabilization.

  16. Assessment of metabolic stability using the rainbow trout (Oncorhynchus mykiss) liver S9 fraction

    Science.gov (United States)

    Standard protocols are given for assessing metabolic stability in rainbow trout using the liver S9 fraction. These protocols describe the isolation of S9 fractions from trout livers, evaluation of metabolic stability using a substrate depletion approach, and expression of the res...

  17. Applying programmatic risk assessment to nuclear materials stabilization R and D planning

    International Nuclear Information System (INIS)

    Brown-Van Hoozer, S.A.; Kenley, C.R.

    1997-01-01

    A systems engineering approach to programmatic risk assessment, derived from the aerospace industry, was applied to various stabilization technologies to assess their relative maturity and availability for use in stabilizing nuclear materials. The assessment provided valuable information for trading off available technologies and identified the at-risk technologies that will require close tracking by the Department of Energy (DOE) to mitigate programmatic risks. This paper presents the programmatic risk assessment methodology developed for the 1995 R and D Plan and updated for the 1996 R and D Plan. Results of the 1996 assessment also are presented (DOE/ID-10561, 1996)

  18. The assessing the economic stability of the agricultural organizations of the Kemerovo region

    Directory of Open Access Journals (Sweden)

    Sekacheva Vera Mikhailovna

    2014-08-01

    Full Text Available The main aspects of the essence of economic stability analyzed in this article. The authors define the concept, the problems and the basic criteria for assessing the economic sustainability of the agricultural organizations of the Kemerovo region.

  19. Original Experimental Approach for Assessing Transport Fuel Stability.

    Science.gov (United States)

    Bacha, Kenza; Ben Amara, Arij; Alves Fortunato, Maira; Wund, Perrine; Veyrat, Benjamin; Hayrault, Pascal; Vannier, Axel; Nardin, Michel; Starck, Laurie

    2016-10-21

    The study of fuel oxidation stability is an important issue for the development of future fuels. Diesel and kerosene fuel systems have undergone several technological changes to fulfill environmental and economic requirements. These developments have resulted in increasingly severe operating conditions whose suitability for conventional and alternative fuels needs to be addressed. For example, fatty acid methyl esters (FAMEs) introduced as biodiesel are more prone to oxidation and may lead to deposit formation. Although several methods exist to evaluate fuel stability (induction period, peroxides, acids, and insolubles), no technique allows one to monitor the real-time oxidation mechanism and to measure the formation of oxidation intermediates that may lead to deposit formation. In this article, we developed an advanced oxidation procedure (AOP) based on two existing reactors. This procedure allows the simulation of different oxidation conditions and the monitoring of the oxidation progress by the means of macroscopic parameters, such as total acid number (TAN) and advanced analytical methods like gas chromatography coupled to mass spectrometry (GC-MS) and Fourier Transform Infrared - Attenuated Total Reflection (FTIR-ATR). We successfully applied AOP to gain an in-depth understanding of the oxidation kinetics of a model molecule (methyl oleate) and commercial diesel and biodiesel fuels. These developments represent a key strategy for fuel quality monitoring during logistics and on-board utilization.

  20. Assessing biogeochemical cycling and transient storage of surface water in Eastern Siberian streams using short-term solute additions

    Science.gov (United States)

    Schade, J. D.; Seybold, E.; Drake, T. W.; Bulygina, E. B.; Bunn, A. G.; Chandra, S.; Davydov, S.; Frey, K. E.; Holmes, R. M.; Sobczak, W. V.; Spektor, V. V.; Zimov, S. A.; Zimov, N.

    2009-12-01

    Recent studies highlight the role of stream networks in the processing of nutrient and organic matter inputs from the surrounding watershed. Clear evidence exists that streams actively regulate fluxes of carbon, nitrogen, and phosphorus from upland terrestrial ecosystems to downstream aquatic environments. This is of particular interest in Arctic streams because of the potential impact of permafrost thaw due to global warming on inputs of nutrients and organic matter to small streams high in the landscape. Knowledge of functional characteristics of these stream ecosystems is paramount to our ability to predict changes in stream ecosystems as climate changes. Biogeochemical models developed by stream ecologists, specifically nutrient spiraling models, provide a set of metrics that we used to assess nutrient processing rates in several streams in the Eastern Siberian Arctic. We quantified these metrics using solute addition experiments in which nitrogen and phosphorus were added simultaneously with chloride as a conservative tracer. We focused on 5 streams, three flowing across upland yedoma soils and two floodplain streams. Yedoma streams showed higher uptake of N than P, suggesting N limitation of biological processes, with large variation between these three streams in the severity of N limitation. Floodplain streams both showed substantially higher P uptake than N uptake, indicating strong P limitation. Given these results, it is probable that these two types of streams will respond quite differently to changes in nutrient and organic matter inputs as permafrost thaws. Furthermore, uptake was strongly linked to discharge and transient storage of surface water, measured using temporal patterns of the conservative tracer, with higher nutrient uptake in low discharge, high transient storage streams. Given the possibility that both discharge and nutrient inputs will increase as permafrost thaws, longer-term nutrient enrichment experiments are needed to develop

  1. Photo stability Assessment in Amorphous-Silicon Solar Cells

    International Nuclear Information System (INIS)

    Gandia, J. J.; Carabe, J.; Fabero, F.; Jimenez, R.; Rivero, J. M.

    1999-01-01

    The present status of amorphous-silicon-solar-cell research and development at CIEMAT requires the possibility to characterise the devices prepared from the point of view of their stability against sunlight exposure. Therefore a set of tools providing such a capacity has been developed. Together with an introduction to photovoltaic applications of amorphous silicon and to the photodegradation problem, the present work describes the process of setting up these tools. An indoor controlled photodegradation facility has been designed and built, and a procedure has been developed for the measurement of J-V characterisation in well established conditions. This method is suitable for all kinds of solar cells, even for those for which no model is still available. The photodegradation and characterisation of some cells has allowed to validate both the new testing facility and method. (Author) 14 refs

  2. Safety Assessment for transient event occurred during the ASTS test of Hanbit Unit 2

    International Nuclear Information System (INIS)

    Yang, Changkeun; Kim, Yohan; Ha, Sangjun

    2014-01-01

    Safety Injection has been actuated during the ASTS (Automatic Seismic Trip System) test of Hanbit Unit 2 on Feb. 28, 2014. It could be bad effect on system integrity. KHNP has been performed safety assessment of system for effect of Safety Injection (SI) actuation occurred during the ASTS test of hanbit Unit 2. Stable state of nuclear power plant system has been confirmed according to Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the power plant is in a safe condition were conformed. After ASTS action, thermal elimination has been processed throughout the turbine until turbine signal occurrence because ASTS is connected to M-G set in the present hanbit Unit 2. Therefore, Safety Injection signal has been actuated by rapid reduction of Steam Generator pressure. In this paper, it is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation. Stable state of nuclear power plant system has been confirmed for Safety Injection and reactor trip event occurred during the ASTS test of hanbit Unit 2. In the result of system safety assessment, major variables of nuclear power plant are located in optimal range and not exceed safety limit. It remains nuclear fuel and the integrity of the plant is in a safe condition were conformed. It is concluded that consideration of equipment and setpoint is needed for that Safety Injection has been not occurred under the unnecessary situation

  3. Assessment of Slope Stability of Various Cut Slopes with Effects of Weathering by Using Slope Stability Probability Classification (SSPC)

    Science.gov (United States)

    Ersöz, Timur; Topal, Tamer

    2017-04-01

    Rocks containing pore spaces, fractures, joints, bedding planes and faults are prone to weathering due to temperature differences, wetting-drying, chemistry of solutions absorbed, and other physical and chemical agents. Especially cut slopes are very sensitive to weathering activities because of disturbed rock mass and topographical condition by excavation. During and right after an excavation process of a cut slope, weathering and erosion may act on this newly exposed rock material. These acting on the material may degrade and change its properties and the stability of the cut slope in its engineering lifetime. In this study, the effect of physical and chemical weathering agents on shear strength parameters of the rocks are investigated in order to observe the differences between weathered and unweathered rocks. Also, slope stability assessment of cut slopes affected by these weathering agents which may disturb the parameters like strength, cohesion, internal friction angle, unit weight, water absorption and porosity are studied. In order to compare the condition of the rock materials and analyze the slope stability, the parameters of weathered and fresh rock materials are found with in-situ tests such as Schmidt hammer and laboratory tests like uniaxial compressive strength, point load and direct shear. Moreover, slake durability and methylene blue tests are applied to investigate the response of the rock to weathering and presence of clays in rock materials, respectively. In addition to these studies, both rock strength parameters and any kind of failure mechanism are determined by probabilistic approach with the help of SSPC system. With these observations, the performances of the weathered and fresh zones of the cut slopes are evaluated and 2-D slope stability analysis are modeled with further recommendations for the cut slopes. Keywords: 2-D Modeling, Rock Strength, Slope Stability, SSPC, Weathering

  4. Reliability assessment of slender concrete columns at the stability failure

    Science.gov (United States)

    Valašík, Adrián; Benko, Vladimír; Strauss, Alfred; Täubling, Benjamin

    2018-01-01

    The European Standard for designing concrete columns within the use of non-linear methods shows deficiencies in terms of global reliability, in case that the concrete columns fail by the loss of stability. The buckling failure is a brittle failure which occurs without warning and the probability of its formation depends on the columns slenderness. Experiments with slender concrete columns were carried out in cooperation with STRABAG Bratislava LTD in Central Laboratory of Faculty of Civil Engineering SUT in Bratislava. The following article aims to compare the global reliability of slender concrete columns with slenderness of 90 and higher. The columns were designed according to methods offered by EN 1992-1-1 [1]. The mentioned experiments were used as basis for deterministic nonlinear modelling of the columns and subsequent the probabilistic evaluation of structural response variability. Final results may be utilized as thresholds for loading of produced structural elements and they aim to present probabilistic design as less conservative compared to classic partial safety factor based design and alternative ECOV method.

  5. High diagnostic yield and accuracy of history, physical examination, and ECG in patients with transient loss of consciousness in FAST: The fainting assessment study

    NARCIS (Netherlands)

    van Dijk, Nynke; Boer, Kimberly R.; Colman, Nancy; Bakker, Annemieke; Stam, Jan; van Grieken, Johannes J. M.; Wilde, Arthur A. M.; Linzer, Mark; Reitsma, Johannes B.; Wieling, Wouter

    2008-01-01

    Yield and Accuracy of Diagnosing TLOC. Background: Transient loss of consciousness (TLOC) is a common clinical problem. Objective: The aim of this study was to assess the yield and accuracy of the initial evaluation, consisting of standardized history, physical examination, and ECG performed by

  6. Performance of real-time strain elastography, transient elastography, and aspartate-to-platelet ratio index in the assessment of fibrosis in chronic hepatitis C.

    Science.gov (United States)

    Ferraioli, Giovanna; Tinelli, Carmine; Malfitano, Antonello; Dal Bello, Barbara; Filice, Gaetano; Filice, Carlo; Above, Elisabetta; Barbarini, Giorgio; Brunetti, Enrico; Calderon, Willy; Di Gregorio, Marta; Lissandrin, Raffaella; Ludovisi, Serena; Maiocchi, Laura; Michelone, Giuseppe; Mondelli, Mario; Patruno, Savino F A; Perretti, Alessandro; Poma, Gianluigi; Sacchi, Paolo; Zaramella, Marco; Zicchetti, Mabel

    2012-07-01

    The purpose of this article is to evaluate the diagnostic performance of transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index in assessing fibrosis in patients with chronic hepatitis C by using histologic Metavir scores as reference standard. Consecutive patients with chronic hepatitis C scheduled for liver biopsy were enrolled. Liver biopsy was performed on the same day as transient elastography and real-time strain elastography. Transient elastography and real-time strain elastography were performed in the same patient encounter by a single investigator using a medical device based on elastometry and an ultrasound machine, respectively. Diagnostic performance was assessed by using receiver operating characteristic curves and area under the receiver operating characteristic curve (AUC) analysis. One hundred thirty patients (91 men and 39 women) were analyzed. The cutoff values for transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index were 6.9 kPa, 1.82, and 0.37, respectively, for fibrosis score of 2 or higher; 7.3 kPa, 1.86, and 0.70, respectively, for fibrosis score of 3 or higher; and 9.3 kPa, 2.33, and 0.70, respectively, for fibrosis score of 4. AUC values of transient elastography, real-time strain elastography, aspartate-to-platelet ratio index were 0.88, 0.74, and 0.86, respectively, for fibrosis score of 2 or higher; 0.95, 0.80, and 0.89, respectively, for fibrosis score of 3 or higher; and 0.97, 0.80, and 0.84, respectively, for fibrosis score of 4. A combination of the three methods, when two of three were in agreement, showed AUC curves of 0.93, 0.95, and 0.95 for fibrosis scores of 2 or higher, 3 or higher, and 4, respectively. Transient elastography, real-time strain elastography, and aspartate-to-platelet ratio index values were correlated with histologic stages of fibrosis. Transient elastography offered excellent diagnostic performance in assessing severe fibrosis and

  7. Transient Electromagnetic Modelling and Imaging of Thin Resistive Structures: Applications for Gas Hydrate Assessment

    Science.gov (United States)

    Swidinsky, Andrei

    Gas hydrates are a solid, ice-like mixture of water and low molecular weight hydrocarbons. They are found under the permafrost and to a far greater extent under the ocean, usually at water depths greater than 300m. Hydrates are a potential energy resource, a possible factor in climate change, and a geohazard. For these reasons, it is critical that gas hydrate deposits are quantitatively assessed so that their concentrations, locations and distributions may be established. Due to their ice-like nature, hydrates are electrically insulating. Consequently, a method which remotely detects changes in seafloor electrical conductivity, such as marine controlled source electromagnetics (CSEM), is a useful geophysical tool for marine gas hydrate exploration. Hydrates are geometrically complex structures. Advanced electromagnetic modelling and imaging techniques are crucial for proper survey design and data interpretation. I develop a method to model thin resistive structures in conductive host media which may be useful in building approximate geological models of gas hydrate deposits using arrangements of multiple, bent sheets. I also investigate the possibility of interpreting diffusive electromagnetic data using seismic imaging techniques. To be processed in this way, such data must first be transformed into its non-diffusive, seismic-like counterpart. I examine such a transform from both an analytical and a numerical point of view, focusing on methods to overcome inherent numerical instabilities. This is the first step to applying seismic processing techniques to CSEM data to rapidly and efficiently image resistive gas hydrate structures. The University of Toronto marine electromagnetics group has deployed a permanent marine CSEM array offshore Vancouver Island, in the framework of the NEPTUNE Canada cabled observatory, for the purposes of monitoring gas hydrate deposits. In this thesis I also propose and examine a new CSEM survey technique for gas hydrate which would

  8. Assessing control of postural stability in community-living older adults using performance-based limits of stability

    Directory of Open Access Journals (Sweden)

    Boissy Patrick

    2008-03-01

    Full Text Available Abstract Background Balance disability measurements routinely used to identify fall risks in frail populations have limited value in the early detection of postural stability deficits in community-living older adults. The objectives of the study were to 1 measure performance-based limits of stability (LOS in community-living older adults and compare them to theoretical LOS computed from data proposed by the Balance Master® system, 2 explore the feasibility of a new measurement approach based on the assessment of postural stability during weight-shifting tasks at performance-based LOS, 3 quantify intra-session performance variability during multiple trials using the performance-based LOS paradigm. Methods Twenty-four healthy community-living older adults (10 men, 14 women aged between 62 to 85 (mean age ± sd, 71.5 ± 6 yrs participated in the study. Subjects' performance-based LOS were established by asking them to transfer their body weight as far as possible in three directions (forward, right and left without changing their base of support. LOS were computed as the maximal excursion of the COP in each direction among three trials. Participants then performed two experimental tasks that consisted in controlling, with the assistance of visual feedback, their centre of pressure (COP within two predefined targets set at 100% of their performance-based LOS. For each tasks 8 trials were performed. Ground reaction forces and torques during performance-based LOS evaluation and experimental tasks were recorded with a force plate. Sway area and medio-lateral mean COP displacement speed variables were extracted from force plate recordings. Results Significant differences between theoretical LOS computed from maximum leaning angles derived from anthropometric characteristics and performance-based LOS were observed. Results showed that a motor learning effect was present as the participants optimized their weight-shifting strategy through the first three

  9. Time of flight MR angiography assessment casts doubt on the association between transient global amnesia and intracranial jugular venous reflux

    International Nuclear Information System (INIS)

    Kang, Yeonah; Kim, Eunhee; Kim, Jae Hyoung; Choi, Byung Se; Jung, Cheolkyu; Bae, Yun Jung; Lee, Kyung Mi; Lee, Dong Hoon

    2015-01-01

    Evidence of intracranial venous reflux flow due to jugular venous reflux (JVR) on time of flight (TOF) MR angiography (MRA) is thought to be highly associated with transient global amnesia (TGA) - evidence that supports the venous congestion theory of TGA pathophysiology. However, recent studies indicate that intracranial JVR on TOF MRA is occasionally observed in normal elderly. Therefore, the purpose of this study was to compare the prevalence of intracranial JVR on TOF MRA in patients with TGA and two control groups. Three age- and sex-matched groups of subjects that received MRI and MRA were enrolled. The groups comprised 167 patients with TGA, 167 visitors to the emergency room (ER) and 167 visitors to a health promotion centre (HPC). Intracranial JVR was defined as abnormal venous signals in the inferior petrosal, sigmoid and/or transverse sinuses on TOF MRA. The prevalence of intracranial JVR was assessed across the three groups. Intracranial JVR was seen in seven (4.2 %) TGA patients, eight (4.8 %) ER visitors and three (1.8 %) HPC visitors, respectively. No statistically significant differences were observed among the three groups. TGA patients showed a low prevalence of intracranial JVR on TOF MRA, and no statistical differences were found in comparison with control groups. (orig.)

  10. Time of flight MR angiography assessment casts doubt on the association between transient global amnesia and intracranial jugular venous reflux

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeonah; Kim, Eunhee; Kim, Jae Hyoung; Choi, Byung Se; Jung, Cheolkyu; Bae, Yun Jung; Lee, Kyung Mi [Seoul National University College of Medicine, Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Lee, Dong Hoon [Seoul Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2014-10-03

    Evidence of intracranial venous reflux flow due to jugular venous reflux (JVR) on time of flight (TOF) MR angiography (MRA) is thought to be highly associated with transient global amnesia (TGA) - evidence that supports the venous congestion theory of TGA pathophysiology. However, recent studies indicate that intracranial JVR on TOF MRA is occasionally observed in normal elderly. Therefore, the purpose of this study was to compare the prevalence of intracranial JVR on TOF MRA in patients with TGA and two control groups. Three age- and sex-matched groups of subjects that received MRI and MRA were enrolled. The groups comprised 167 patients with TGA, 167 visitors to the emergency room (ER) and 167 visitors to a health promotion centre (HPC). Intracranial JVR was defined as abnormal venous signals in the inferior petrosal, sigmoid and/or transverse sinuses on TOF MRA. The prevalence of intracranial JVR was assessed across the three groups. Intracranial JVR was seen in seven (4.2 %) TGA patients, eight (4.8 %) ER visitors and three (1.8 %) HPC visitors, respectively. No statistically significant differences were observed among the three groups. TGA patients showed a low prevalence of intracranial JVR on TOF MRA, and no statistical differences were found in comparison with control groups. (orig.)

  11. Bioassessment in nonperennial streams: Hydrologic stability influences assessment validity

    Science.gov (United States)

    Mazor, R. D.; Stein, E. D.; Schiff, K.; Ode, P.; Rehn, A.

    2011-12-01

    Nonperennial streams pose a challenge for bioassessment, as assessment tools developed in perennial streams may not work in these systems. For example, indices of biotic integrity (IBIs) developed in perennial streams may give improper indications of impairment in nonperennial streams, or may be unstable. We sampled benthic macroinvertebrates from 12 nonperennial streams in southern California. In addition, we deployed loggers to obtain continuous measures of flow. 3 sites were revisited over 2 years. For each site, we calculated several metrics, IBIs, and O/E scores to determine if assessments were consistent and valid throughout the summer. Hydrology varied widely among the streams, with several streams drying between sampling events. IBIs suggested good ecological health at the beginning of the study, but declined sharply at some sites. Multivariate ordination suggested that, despite differences among sites, changes in community structure were similar, with shifts from Ephemeroptera, Plecoptera, and Trichoptera to Coleoptera and more tolerant organisms. Site revisits revealed a surprising level of variability, as 2 of the 3 revisited sites had perennial or near-perennial flow in the second year of sampling. IBI scores were more consistent in streams with stable hydrographs than in those with strongly intermittent hydrographs. These results suggest that nonperennial streams can be monitored successfully, but they may require short index periods and distinct metrics from those used in perennial streams. In addition, better approaches to mapping nonperennial streams are required.

  12. Modeling and Stability Assessment of Single-Phase Grid Synchronization Techniques

    DEFF Research Database (Denmark)

    Golestan, Saeed; Guerrero, Josep M.; Vasquez, Juan

    2018-01-01

    (GSTs) is of vital importance. This task is most often based on obtaining a linear time-invariant (LTI) model for the GST and applying standard stability tests to it. Another option is modeling and dynamics/stability assessment of GSTs in the linear time-periodic (LTP) framework, which has received...... a very little attention. In this letter, the procedure of deriving the LTP model for single-phase GSTs is first demonstrated. The accuracy of the LTP model in predicting the GST dynamic behavior and stability is then evaluated and compared with that of the LTI one. Two well-known single-phase GSTs, i...

  13. GECM-Based Voltage Stability Assessment Using Wide-Area Synchrophasors

    OpenAIRE

    Heng-Yi Su; Tzu-Yi Liu

    2017-01-01

    Voltage instability is a crucial issue in the secure operation of power grids. Several methods for voltage stability assessment were presented. Some of them are highly computationally intensive, while others are reported not to work properly under all circumstances. This paper proposes a new methodology based on the generator equivalent circuit model (GECM) and the phasor measurement unit (PMU) technology for online voltage stability monitoring of a power grid. First, the proposed methodology...

  14. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  15. Chronic in vivo stability assessment of carbon fiber microelectrode arrays

    Science.gov (United States)

    Patel, Paras R.; Zhang, Huanan; Robbins, Matthew T.; Nofar, Justin B.; Marshall, Shaun P.; Kobylarek, Michael J.; Kozai, Takashi D. Y.; Kotov, Nicholas A.; Chestek, Cynthia A.

    2016-12-01

    Objective. Individual carbon fiber microelectrodes can record unit activity in both acute and semi-chronic (∼1 month) implants. Additionally, new methods have been developed to insert a 16 channel array of carbon fiber microelectrodes. Before assessing the in vivo long-term viability of these arrays, accelerated soak tests were carried out to determine the most stable site coating material. Next, a multi-animal, multi-month, chronic implantation study was carried out with carbon fiber microelectrode arrays and silicon electrodes. Approach. Carbon fibers were first functionalized with one of two different formulations of PEDOT and subjected to accelerated aging in a heated water bath. After determining the best PEDOT formula to use, carbon fiber arrays were chronically implanted in rat motor cortex. Some rodents were also implanted with a single silicon electrode, while others received both. At the end of the study a subset of animals were perfused and the brain tissue sliced. Tissue sections were stained for astrocytes, microglia, and neurons. The local reactive responses were assessed using qualitative and quantitative methods. Main results. Electrophysiology recordings showed the carbon fibers detecting unit activity for at least 3 months with average amplitudes of ∼200 μV. Histology analysis showed the carbon fiber arrays with a minimal to non-existent glial scarring response with no adverse effects on neuronal density. Silicon electrodes showed large glial scarring that impacted neuronal counts. Significance. This study has validated the use of carbon fiber microelectrode arrays as a chronic neural recording technology. These electrodes have demonstrated the ability to detect single units with high amplitude over 3 months, and show the potential to record for even longer periods. In addition, the minimal reactive response should hold stable indefinitely, as any response by the immune system may reach a steady state after 12 weeks.

  16. Assessing the relative stabilities of engineered hemoglobins using electrospray mass spectrometry.

    Science.gov (United States)

    Apostol, I

    1999-07-15

    An ion trap mass spectrometer equipped with an electrospray source was used to examine the relative thermodynamic stabilities of various hemoglobins with respect to both tetramer dissociation and hemin dissociation. The results demonstrated that the stability of hemoglobin molecules can be differentiated by the amount of applied collision-induced dissociation (CID) energy necessary to break up the intact tetramer into its constituent globins. The stability of the intact tetramer was affected by single mutations in the beta-globins. The stabilities of the constituent hologlobins were assessed via trap CID of selected ions. The results demonstrated the importance of the contributions of the hologlobin components to the stability of the intact tetramer. Genetic fusion of two alpha-globins, through the introduction of a single glycine residue between the C-terminus of one alpha-chain and the N-terminus of the second, significantly increased the stability of the hemoglobin pseudo-tetramer. Chemical crosslinking of the beta-globins in addition to genetic fusion of alpha-globins further stabilized the hemoglobin molecule. A dihemoglobin molecule produced by the genetic fusion of two di-alpha-globins with a flexible linker demonstrated a decreased stability relative to the corresponding monohemoglobin. Copyright 1999 Academic Press.

  17. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    Science.gov (United States)

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  18. PWR systems transient analysis

    International Nuclear Information System (INIS)

    Kennedy, M.F.; Peeler, G.B.; Abramson, P.B.

    1985-01-01

    Analysis of transients in pressurized water reactor (PWR) systems involves the assessment of the response of the total plant, including primary and secondary coolant systems, steam piping and turbine (possibly including the complete feedwater train), and various control and safety systems. Transient analysis is performed as part of the plant safety analysis to insure the adequacy of the reactor design and operating procedures and to verify the applicable plant emergency guidelines. Event sequences which must be examined are developed by considering possible failures or maloperations of plant components. These vary in severity (and calculational difficulty) from a series of normal operational transients, such as minor load changes, reactor trips, valve and pump malfunctions, up to the double-ended guillotine rupture of a primary reactor coolant system pipe known as a Large Break Loss of Coolant Accident (LBLOCA). The focus of this paper is the analysis of all those transients and accidents except loss of coolant accidents

  19. ASSESSMENT OF TECHNETIUM LEACHABILITY IN CEMENT STABILIZED BASIN 43 GROUNDWATER BRINE

    International Nuclear Information System (INIS)

    COOKE GA; DUNCAN JB; LOCKREM LL

    2008-01-01

    This report is an initial report on the laboratory effort executed under RPP-PLAN-33338, Test Plan for the Assessment of Technetium Leachability in Cement-Stabilized Basin 43 Groundwater Brine. This report delineates preliminary data obtained under subcontract 21065, release 30, from the RJ Lee Group, Inc., Center for Laboratory Sciences. The report is predicated on CLS RPT-816, Draft Report: Assessment of Technetium Leachability in Cement Stabilized Basin 43 Groundwater Brine. This document will be revised on receipt of the final RJ Lee Group, Inc., Center for Laboratory Sciences report, which will contain data subjected to quality control and quality assurance criteria

  20. Passivity-Based Stability Assessment of Grid-Connected VSCs - An Overview

    DEFF Research Database (Denmark)

    Harnefors, Lennart; Wang, Xiongfei; Yepes, Alejandro G.

    2016-01-01

    The interconnection stability of a grid-connected voltage-source converter (VSC) can be assessed by the passivity properties of the VSC input admittance. If critical grid resonances fall within regions where the input admittance acts passively, i.e., has nonnegative real part, then their destabil......The interconnection stability of a grid-connected voltage-source converter (VSC) can be assessed by the passivity properties of the VSC input admittance. If critical grid resonances fall within regions where the input admittance acts passively, i.e., has nonnegative real part...

  1. Evaluation of HVDC interconnection models for considering its impact in real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Lund, P.

    2015-01-01

    An approach to evaluate the HVDC interconnectionsmodels to be used in real-time voltage stability assessment is proposed.The existing models for the HVDC interconnections, thatare based on voltage source converter, were studied selecting theones that are suitable for its application in Thevenin...... equivalent ´methods for voltage stability assessment. The proposed methodis to evaluate the validity of the models by using synthetizedPMU measurements from simulations and from PMUs connectedto the danish system. Wide-area measurements are used toestimate the HVDC model parameters which are needed...

  2. A rapid stability assessment of China's IGS sites after the Ms7. 0 Lushan earthquake

    Directory of Open Access Journals (Sweden)

    Meng Jie

    2013-05-01

    Full Text Available A rapid and accurate assessment of the stability of surveying and mapping reference points is important for post – disaster rescue, disaster relief and reconstruction activities. Using Precise Point Positioning (PPP technology, a rapid assessment of the stability of the IGS sites in China was performed after the Ms 7. 0 Lushan earthquake using rapid precise ephemeris and rapid precise satellite clock products. The results show that the earthquake had a very small impact and did not cause significant permanent deformation at the IGS sites. Most of the sites were unaffected and remained stable after the earthquake.

  3. ATM and SIRT6/SNF2H Mediate Transient H2AX Stabilization When DSBs Form by Blocking HUWE1 to Allow Efficient γH2AX Foci Formation

    Directory of Open Access Journals (Sweden)

    Yuko Atsumi

    2015-12-01

    Full Text Available In response to DNA double-strand breaks (DSBs, H2AX is rapidly phosphorylated at Ser139 to promote DSB repair. Here we show that H2AX is rapidly stabilized in response to DSBs to efficiently generate γH2AX foci. This mechanism operated even in quiescent cells that barely expressed H2AX. H2AX stabilization resulted from the inhibition of proteasome-mediated degradation. Synthesized H2AX ordinarily underwent degradation through poly-ubiquitination mediated by the E3 ligase HUWE1; however, H2AX ubiquitination was transiently halted upon DSB formation. Such rapid H2AX stabilization by DSBs was associated with chromatin incorporation of H2AX and halting of its poly-ubiquitination mediated by the ATM kinase, the sirtuin protein SIRT6, and the chromatin remodeler SNF2H. H2AX Ser139, the ATM phosphorylation site, was essential for H2AX stabilization upon DSB formation. Our results reveal a pathway controlled by ATM, SIRT6, and SNF2H to block HUWE1, which stabilizes H2AX and induces its incorporation into chromatin only when cells are damaged.

  4. An Assessment of Economic Stability under the New European Economic Governance

    Directory of Open Access Journals (Sweden)

    Gheorghe HURDUZEU

    2015-06-01

    Full Text Available The economic crisis, followed by the sovereign debt crisis, resulted in high unemployment, unsustainable public finances and deepening disparities between Euro Area member states, and underlined the necessity of strengthening economic coordination. In order to lessen the effects of the crises, to prevent further deepening of the economic context and the appearance of new similar situations, the European framework was improved by the provisions of the new economic governance. The aim of this paper is to assess the effects regarding macroeconomic stability within Euro Area member states, achieved under the new economic governance framework. In this respect, the first part of the paper consists in an overview of the provisions imposed through the European Semester, the reformed Stability and Growth Pact and the other elements of the new European governance. In order to assess the achievement of economic stability we analyzed data for Southern Euro Area member states, during 2009-2013, as this group of countries registered most issues during 2013. We took into consideration five important indicators, essential in any economy that form the macroeconomic stability pentagon: economic growth rate, unemployment rate, inflation rate, budgetary balance and current account balance. By comparing the area obtained through the macroeconomic stability pentagon, we conclude on meeting one of the main objectives of the new European governance: economic stability.

  5. Assessing the implications of human land-use change for the transient climate response to cumulative carbon emissions

    International Nuclear Information System (INIS)

    Simmons, C T; Matthews, H D

    2016-01-01

    Recent research has shown evidence of a linear climate response to cumulative CO 2 emissions, which implies that the source, timing, and amount of emissions does not significantly influence the climate response per unit emission. Furthermore, these analyses have generally assumed that the climate response to land-use CO 2 emissions is equivalent to that of fossil fuels under the assumption that, once in the atmosphere, the radiative forcing induced by CO 2 is not sensitive to the emissions source. However, land-cover change also affects surface albedo and the strength of terrestrial carbon sinks, both of which have an additional climate effect. In this study, we use a coupled climate-carbon cycle model to assess the climate response to historical and future cumulative land-use CO 2 emissions, in order to compare it to the response to fossil fuel CO 2 . We find that when we isolate the CO 2 -induced (biogeochemical) temperature changes associated with land-use change, then the climate response to cumulative land-use emissions is equivalent to that of fossil fuel CO 2 . We show further that the globally-averaged albedo-induced biophysical cooling from land-use change is non-negligible and may be of comparable magnitude to the biogeochemical warming, with the result that the net climate response to land-use change is substantially different from a linear response to cumulative emissions. However, our new simulations suggest that the biophysical cooling from land-use change follows its own independent (negative) linear response to cumulative net land-use CO 2 emissions, which may provide a useful scaling factor for certain applications when evaluating the full transient climate response to emissions. (letter)

  6. Developing a stability assessment method for power electronics-based microgrids

    Science.gov (United States)

    Austin, Peter M.

    Modern microgrids with microsources and energy storage are dependent on power electronics for control and regulation. Under certain circumstances power electronics can be destabilizing to the system due to an effect called negative incremental impedance. A careful review of the theory and literature on the subject is presented. This includes stability criteria for both AC and DC systems, as well as a discussion on the limitations posed by the analysis. A method to integrate stability assessment with higher-level microgrid architectural design is proposed. Crucial to this is impedance characterization of individual components, which was accomplished through simulation. DC and AC impedance measurement blocks were created in Matlab simulink to automate the process. A detailed switching-level model of a DC microgrid was implemented in simulink, including wind turbine microsource, battery storage, and three phase inverter. Maximum power point tracking (MPPT) was included to maximize the efficiency of the turbine and was implemented through three rectifier alternatives and control schemes. The stability characteristics of each was compared in the final analysis. Impedance data was collected individually from the components and used to assess stability in the system as a whole. The results included the assessment of stability, margin, and unstable operating points to demonstrate the feasibility of the proposed approach.

  7. Urinary Biomarkers IGFBP7 and TIMP-2 for the Diagnostic Assessment of Transient and Persistent Acute Kidney Injury in Critically Ill Patients

    Science.gov (United States)

    Daubin, Delphine; Cristol, Jean Paul; Dupuy, Anne Marie; Kuster, Nils; Besnard, Noémie; Platon, Laura; Buzançais, Aurèle; Brunot, Vincent; Garnier, Fanny; Jonquet, Olivier; Klouche, Kada

    2017-01-01

    Objective The capability of urinary TIMP-2 (tissue inhibitor of metalloproteinase) and IGFBP7 (insulin-like growth factor binding protein)—NephroCheck Test (NC) = ([TIMP-2] x [IGFBP7]) / 1000)—to predict renal recovery from acute kidney injury (AKI) has been poorly studied. The aim of this study was to assess the performance of measurements of ([TIMP-2] x [IGFBP7]) / 1000) over 24 hours to differentiate transient from persistent AKI. Methods Of 460 consecutive adult patients admitted to the ICU, 101 were prospectively studied: 56 men, 62 (52–71) years old. A fresh urine sample was collected at H0, H4, H12 and H24 to determine ([TIMP-2] x [IGFBP7]) / 1000) levels. Areas under the curves of Delta NC H4-Ho and H12-H4 and serum creatinine (sCr) for detection of AKI recovery were compared. Results Forty-one (40.6%) patient were diagnosed with AKI: 27 transient and 14 persistent AKI. At admission (H0), AKI patients had a significantly higher NC score than patients without AKI (0.43 [0.07–2.06] vs 0.15 [0.07–0.35], p = 0.027). In AKI groups, transient AKI have a higher NC, at H0 and H4, than persistent AKI (0.87 [0.09–2.82] vs 0.13 [0.05–0.66] p = 0.035 and 0.13 [0.07–0.61] vs 0.05 [0.02–0.13] p = 0.013). Thereafter, NC level decreased in both AKI groups with a Delta NC score H4-H0 and H12-H4 significantly more important in transient AKI. Roc curves showed however that delta NC scores did not discriminate between transient and persistent AKI. Conclusion In our population, absolute urinary levels of NC score were higher at early hours after ICU admission (H0 and H4) in transient AKI as compared to persistent AKI patients. NC variations (Delta NC scores) over the first 12 hours may indicate the AKI’s evolving nature with a more significant decrease in case of transient AKI but were not able to differentiate transient from persistent AKI. PMID:28085896

  8. Urinary Biomarkers IGFBP7 and TIMP-2 for the Diagnostic Assessment of Transient and Persistent Acute Kidney Injury in Critically Ill Patients.

    Directory of Open Access Journals (Sweden)

    Delphine Daubin

    Full Text Available The capability of urinary TIMP-2 (tissue inhibitor of metalloproteinase and IGFBP7 (insulin-like growth factor binding protein-NephroCheck Test (NC = ([TIMP-2] x [IGFBP7] / 1000-to predict renal recovery from acute kidney injury (AKI has been poorly studied. The aim of this study was to assess the performance of measurements of ([TIMP-2] x [IGFBP7] / 1000 over 24 hours to differentiate transient from persistent AKI.Of 460 consecutive adult patients admitted to the ICU, 101 were prospectively studied: 56 men, 62 (52-71 years old. A fresh urine sample was collected at H0, H4, H12 and H24 to determine ([TIMP-2] x [IGFBP7] / 1000 levels. Areas under the curves of Delta NC H4-Ho and H12-H4 and serum creatinine (sCr for detection of AKI recovery were compared.Forty-one (40.6% patient were diagnosed with AKI: 27 transient and 14 persistent AKI. At admission (H0, AKI patients had a significantly higher NC score than patients without AKI (0.43 [0.07-2.06] vs 0.15 [0.07-0.35], p = 0.027. In AKI groups, transient AKI have a higher NC, at H0 and H4, than persistent AKI (0.87 [0.09-2.82] vs 0.13 [0.05-0.66] p = 0.035 and 0.13 [0.07-0.61] vs 0.05 [0.02-0.13] p = 0.013. Thereafter, NC level decreased in both AKI groups with a Delta NC score H4-H0 and H12-H4 significantly more important in transient AKI. Roc curves showed however that delta NC scores did not discriminate between transient and persistent AKI.In our population, absolute urinary levels of NC score were higher at early hours after ICU admission (H0 and H4 in transient AKI as compared to persistent AKI patients. NC variations (Delta NC scores over the first 12 hours may indicate the AKI's evolving nature with a more significant decrease in case of transient AKI but were not able to differentiate transient from persistent AKI.

  9. Assessment of engineering plant analyzer with Peach Bottom 2 stability tests

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Mallen, A.N.; Cheng, H.S.; Wulff, W.

    1992-01-01

    Engineering Plant Analyzer (EPA) has been developed to simulate plant transients for Boiling Water Reactor (BWR). Recently, this code has been used to simulate LaSalle-2 instability event which was initiated by a failure in the feed water heater. The simulation was performed for the scram conditions and for the postulated failure in the scram. In order to assess the capability of the EPA to simulate oscillatory flows as observed in the LaSalle event, EPA has been benchmarked with the available data from the Peach Bottom 2 (PB2) Instability tests PT1, PT2, and PT4. This document provides a description of these tests

  10. Chernobyl reactor transient simulation study

    International Nuclear Information System (INIS)

    Gaber, F.A.; El Messiry, A.M.

    1988-01-01

    This paper deals with the Chernobyl nuclear power station transient simulation study. The Chernobyl (RBMK) reactor is a graphite moderated pressure tube type reactor. It is cooled by circulating light water that boils in the upper parts of vertical pressure tubes to produce steam. At equilibrium fuel irradiation, the RBMK reactor has a positive void reactivity coefficient. However, the fuel temperature coefficient is negative and the net effect of a power change depends upon the power level. Under normal operating conditions the net effect (power coefficient) is negative at full power and becomes positive under certain transient conditions. A series of dynamic performance transient analysis for RBMK reactor, pressurized water reactor (PWR) and fast breeder reactor (FBR) have been performed using digital simulator codes, the purpose of this transient study is to show that an accident of Chernobyl's severity does not occur in PWR or FBR nuclear power reactors. This appears from the study of the inherent, stability of RBMK, PWR and FBR under certain transient conditions. This inherent stability is related to the effect of the feed back reactivity. The power distribution stability in the graphite RBMK reactor is difficult to maintain throughout its entire life, so the reactor has an inherent instability. PWR has larger negative temperature coefficient of reactivity, therefore, the PWR by itself has a large amount of natural stability, so PWR is inherently safe. FBR has positive sodium expansion coefficient, therefore it has insufficient stability it has been concluded that PWR has safe operation than FBR and RBMK reactors

  11. Wide-Area Assessment of Aperiodic Small Signal Rotor Angle Stability in Real-Time

    DEFF Research Database (Denmark)

    Jóhannsson, Hjörtur; Nielsen, Arne Hejde; Østergaard, Jacob

    2013-01-01

    This paper presents the details of a new real-time stability assessment method. The method assesses a particular mechanism of stability: each generator’s capability to generate sufficient steady state electromechanical torque. The lack of sufficient steady state torque causes aperiodic increase...... of multiple operating points is derived in the paper. Finally, results from time-domain simulation of instability scenarios in the Nordic32 test system are presented and results used for testing the assessment method. The results illustrate the method’s capability to efficiently identify the location...... in rotor angle and a loss of synchronism, referred to as aperiodic small signal instability. The paper provides the theoretical background of the method and an analytical assessment criterion. Furthermore, a mathematical mapping of the generators’ operating points that enables informative visualization...

  12. Study on transient stability of asynchronous wind turbine based on series dynamic braking resistor%基于串联动态制动电阻的异步风电机组暂态稳定性研究

    Institute of Scientific and Technical Information of China (English)

    肖兰; 赵斌; 李建; 范镇南

    2011-01-01

    以并网笼型异步风电机组为例,分析了利用串联动态制动电阻提高并网异步风电机组在电网故障下暂态稳定性的作用机理以及效果.建立了并网异步风电机组的数学模型,基于Matlab/Simulink仿真平台,对比分析了采用串联动态制动电阻、并联动态制动电阻以及无功补偿装置的作用效果.仿真结果表明,采用串联动态制动电阻可以有效改善并网异步风力发电机组的暂态稳定性;同时,采用串联动态制动电阻和无功补偿装置,可显著提高机组的暂态稳定性,减少对无功补偿的需求,降低风电场的运行成本.%Take the squirrel-cage type asynchronous wind turbine as example, the mechanism and efficiency of the improvement on the transient stability of wind turbine with grid-connected used by series dynamic braking resistor under the power grid fault is analyzed, the mathematical model of asynchronous wind turbine.with grid-connected is established, the transient behaviors of the wind turbine generator system using series dynamic breaking resistor, parallel dynamic breaking resistor and reactive compensation device are analyzed and compared based on Matlab/Simulink,. The simulation results have shown that the series dynamic breaking resistor can effectively improve the transient stability of asynchronous wind turbine system. Using series dynamic breaking resistor and reactive compensation device simultaneously can improve the transient stability of wind turbine generator system significantly , which reducing the reactive compensation requirement and cost of wind farm.

  13. Methods Used to Assess the Susceptibility to Contamination of Transient, Non-Community Public Ground-Water Supplies in Indiana

    Science.gov (United States)

    Arihood, Leslie D.; Cohen, David A.

    2006-01-01

    The Safe Water Drinking Act of 1974 as amended in 1996 gave each State the responsibility of developing a Source-Water Assessment Plan (SWAP) that is designed to protect public-water supplies from contamination. Each SWAP must include three elements: (1) a delineation of the source-water protection area, (2) an inventory of potential sources of contaminants within the area, and (3) a determination of the susceptibility of the public-water supply to contamination from the inventoried sources. The Indiana Department of Environmental Management (IDEM) was responsible for preparing a SWAP for all public-water supplies in Indiana, including about 2,400 small public ground-water supplies that are designated transient, non-community (TNC) supplies. In cooperation with IDEM, the U.S. Geological Survey compiled information on conditions near the TNC supplies and helped IDEM complete source-water assessments for each TNC supply. The delineation of a source-water protection area (called the assessment area) for each TNC ground-water supply was defined by IDEM as a circular area enclosed by a 300-foot radius centered at the TNC supply well. Contaminants of concern (COCs) were defined by IDEM as any of the 90 contaminants for which the U.S. Environmental Protection Agency has established primary drinking-water standards. Two of these, nitrate as nitrogen and total coliform bacteria, are Indiana State-regulated contaminants for TNC water supplies. IDEM representatives identified potential point and nonpoint sources of COCs within the assessment area, and computer database retrievals were used to identify potential point sources of COCs in the area outside the assessment area. Two types of methods-subjective and subjective hybrid-were used in the SWAP to determine susceptibility to contamination. Subjective methods involve decisions based upon professional judgment, prior experience, and (or) the application of a fundamental understanding of processes without the collection and

  14. Consistency and Stability of Italian Children's Spelling in Dictation versus Composition Assessments

    Science.gov (United States)

    Bigozzi, Lucia; Tarchi, Christian; Pinto, Giuliana

    2017-01-01

    The purpose of this study was to investigate consistency in spelling skills across 2 different tasks of written production (dictation vs. composition) and stability of performance across 4 different grades. We assessed 2nd, 3rd, 4th, and 5th graders' spelling performance through 4 tasks: 2 dictation tasks (passage and sentences) and 2 composition…

  15. Toward ambulatory balance assessment: Estimating variability and stability from short bouts of gait

    NARCIS (Netherlands)

    van Schooten, K.S.; Rispens, S.M.; Elders, P.J.M.; van Dieen, J.H.; Pijnappels, M.A.G.M.

    2014-01-01

    Stride-to-stride variability and local dynamic stability of gait kinematics are promising measures to identify individuals at increased risk of falling. This study aimed to explore the feasibility of using these metrics in clinical practice and ambulatory assessment, where only a small number of

  16. Toward a generalized computational workflow for exploiting transient pockets as new targets for small molecule stabilizers: Application to the homogentisate 1,2-dioxygenase mutants at the base of rare disease Alkaptonuria.

    Science.gov (United States)

    Bernini, Andrea; Galderisi, Silvia; Spiga, Ottavia; Bernardini, Giulia; Niccolai, Neri; Manetti, Fabrizio; Santucci, Annalisa

    2017-10-01

    Alkaptonuria (AKU) is an inborn error of metabolism where mutation of homogentisate 1,2-dioxygenase (HGD) gene leads to a deleterious or misfolded product with subsequent loss of enzymatic degradation of homogentisic acid (HGA) whose accumulation in tissues causes ochronosis and degeneration. There is no licensed therapy for AKU. Many missense mutations have been individuated as responsible for quaternary structure disruption of the native hexameric HGD. A new approach to the treatment of AKU is here proposed aiming to totally or partially rescue enzyme activity by targeting of HGD with pharmacological chaperones, i.e. small molecules helping structural stability. Co-factor pockets from oligomeric proteins have already been successfully exploited as targets for such a strategy, but no similar sites are present at HGD surface; hence, transient pockets are here proposed as a target for pharmacological chaperones. Transient pockets are detected along the molecular dynamics trajectory of the protein and filtered down to a set of suitable sites for structural stabilization by mean of biochemical and pharmacological criteria. The result is a computational workflow relevant to other inborn errors of metabolism requiring rescue of oligomeric, misfolded enzymes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Assessment of a pressurizer spray valve faulty opening transient at Asco Nuclear Power Plant with RELAP5/MOD2

    International Nuclear Information System (INIS)

    Reventos, F.; Baptista, J.S.; Navas, A.P.; Moreno, P.

    1993-12-01

    The Asociacion Nuclear Asco has prepared a model of Asco NPP using RELAP5/MOD2. This model, which include thermalhydraulics, kinetics and protection and controls, has been qualified in previous calculations of several actual plant transients. One of the transients of the qualification process is a ''Pressurizer spray valve faulty opening'' presented in this report. It consists in a primary coolant depressurization that causes the reactor trip by overtemperature and later on the actuation of the safety injection. The results are in close agreement with plant data

  18. Stabilization of diastolic calcium signal via calcium pump regulation of complex local calcium releases and transient decay in a computational model of cardiac pacemaker cell with individual release channels.

    Directory of Open Access Journals (Sweden)

    Alexander V Maltsev

    2017-08-01

    Full Text Available Intracellular Local Ca releases (LCRs from sarcoplasmic reticulum (SR regulate cardiac pacemaker cell function by activation of electrogenic Na/Ca exchanger (NCX during diastole. Prior studies demonstrated the existence of powerful compensatory mechanisms of LCR regulation via a complex local cross-talk of Ca pump, release and NCX. One major obstacle to study these mechanisms is that LCR exhibit complex Ca release propagation patterns (including merges and separations that have not been characterized. Here we developed new terminology, classification, and computer algorithms for automatic detection of numerically simulated LCRs and examined LCR regulation by SR Ca pumping rate (Pup that provides a major contribution to fight-or-flight response. In our simulations the faster SR Ca pumping accelerates action potential-induced Ca transient decay and quickly clears Ca under the cell membrane in diastole, preventing premature releases. Then the SR generates an earlier, more synchronized, and stronger diastolic LCR signal activating an earlier and larger inward NCX current. LCRs at higher Pup exhibit larger amplitudes and faster propagation with more collisions to each other. The LCRs overlap with Ca transient decay, causing an elevation of the average diastolic [Ca] nadir to ~200 nM (at Pup = 24 mM/s. Background Ca (in locations lacking LCRs quickly decays to resting Ca levels (<100 nM at high Pup, but remained elevated during slower decay at low Pup. Release propagation is facilitated at higher Pup by a larger LCR amplitude, whereas at low Pup by higher background Ca. While at low Pup LCRs show smaller amplitudes, their larger durations and sizes combined with longer transient decay stabilize integrals of diastolic Ca and NCX current signals. Thus, the local interplay of SR Ca pump and release channels regulates LCRs and Ca transient decay to insure fail-safe pacemaker cell operation within a wide range of rates.

  19. Assessment of SFR reactor safety issues: Part II: Analysis results of ULOF transients imposed on a variety of different innovative core designs with SAS-SFR

    Energy Technology Data Exchange (ETDEWEB)

    Kruessmann, R., E-mail: regina.kruessmann@kit.edu [Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology INR, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Ponomarev, A.; Pfrang, W.; Struwe, D. [Karlsruhe Institute of Technology, Institute of Neutron Physics and Reactor Technology INR, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Champigny, J.; Carluec, B. [AREVA, 10, rue J. Récamier, 69456 Lyon Cedex 06 (France); Schmitt, D.; Verwaerde, D. [EDF R& D, 1 avenue du général de Gaulle, 92140 Clamart (France)

    2015-04-15

    Highlights: • Comparison of different core designs for a sodium-cooled fast reactor. • Safety assessment with the code system SAS-SFR. • Unprotected Loss of Flow (ULOF) scenario. • Sodium boiling and core melting cannot be avoided. • A net negative Na void effect provides more grace time prior to local SA destruction. - Abstract: In the framework of cooperation agreements between KIT-INR and AREVA SAS NP as well as between KIT-INR and EDF R&D in the years 2008–2013, the evaluation of severe transient behavior in sodium-cooled fast reactors (SFRs) was investigated. In Part I of this contribution, the efficiency of newly conceived prevention and mitigation measures was investigated for unprotected loss-of-flow (ULOF), unprotected loss-of-heat-sink (ULOHS) and the unprotected transient-overpower (UTOP) transients. In this second part, consequence analyses were performed for the initiation phase of different unprotected loss-of-flow (ULOF) scenarios imposed on a variety of different core design options of SFRs. The code system SAS-SFR was used for this purpose. Results of analyses for cases postulating unavailability of prevention measures as shut-down systems, passive and/or active additional devices show that entering into an energetic power excursion as a consequence of the initiation phase of a ULOF cannot be avoided for those core designs with a cumulative void reactivity feedback larger than zero. However, even for core designs aiming at values of the void reactivity less than zero it is difficult to find system design characteristics which prevent the transient entering into partial core destruction. Further studies of the transient core and system behavior would require codes dedicated to specific aspects of transition phase analyses and of in-vessel material relocation analyses.

  20. Transient and 2-Dimensional Shear-Wave Elastography Provide Comparable Assessment of Alcoholic Liver Fibrosis and Cirrhosis

    DEFF Research Database (Denmark)

    Thiele, Maja; Detlefsen, Sönke; Møller, Linda Maria Sevelsted

    2016-01-01

    clinics (in Southern Denmark). The second, lower-risk group, was recruited from municipal alcohol rehabilitation centers and the Danish national public health portal. All subjects underwent same-day transient elastography (FibroScan), 2-dimensional shear wave elastography (Supersonic Aixplorer), and liver...

  1. Stabilization of emission of CO2: A computable general equilibrium assessment

    International Nuclear Information System (INIS)

    Glomsroed, S.; Vennemo, H.; Johnsen, T.

    1992-01-01

    A multisector computable general equilibrium model is used to study economic development perspectives in Norway if CO 2 emissions were stabilized. The effects discussed include impacts on main macroeconomic indicators and economic growth, sectoral allocation of production, and effects on the market for energy. The impact of other pollutants than CO 2 on emissions is assessed along with the related impact on noneconomic welfare. The results indicate that CO 2 emissions might be stabilized in Norway without dramatically reducing economic growth. Sectoral allocation effects are much larger. A substantial reduction in emissions to air other than CO 2 is found, yielding considerable gains in noneconomic welfare. 25 refs., 6 tabs., 2 figs

  2. Kinematic measures for assessing gait stability in elderly individuals: a systematic review.

    Science.gov (United States)

    Hamacher, D; Singh, N B; Van Dieën, J H; Heller, M O; Taylor, W R

    2011-12-07

    Falls not only present a considerable health threat, but the resulting treatment and loss of working days also place a heavy economic burden on society. Gait instability is a major fall risk factor, particularly in geriatric patients, and walking is one of the most frequent dynamic activities of daily living. To allow preventive strategies to become effective, it is therefore imperative to identify individuals with an unstable gait. Assessment of dynamic stability and gait variability via biomechanical measures of foot kinematics provides a viable option for quantitative evaluation of gait stability, but the ability of these methods to predict falls has generally not been assessed. Although various methods for assessing gait stability exist, their sensitivity and applicability in a clinical setting, as well as their cost-effectiveness, need verification. The objective of this systematic review was therefore to evaluate the sensitivity of biomechanical measures that quantify gait stability among elderly individuals and to evaluate the cost of measurement instrumentation required for application in a clinical setting. To assess gait stability, a comparative effect size (Cohen's d) analysis of variability and dynamic stability of foot trajectories during level walking was performed on 29 of an initial yield of 9889 articles from four electronic databases. The results of this survey demonstrate that linear variability of temporal measures of swing and stance was most capable of distinguishing between fallers and non-fallers, whereas step width and stride velocity prove more capable of discriminating between old versus young (OY) adults. In addition, while orbital stability measures (Floquet multipliers) applied to gait have been shown to distinguish between both elderly fallers and non-fallers as well as between young and old adults, local stability measures (λs) have been able to distinguish between young and old adults. Both linear and nonlinear measures of foot

  3. Local Dynamic Stability Assessment of Motion Impaired Elderly Using Electronic Textile Pants.

    Science.gov (United States)

    Liu, Jian; Lockhart, Thurmon E; Jones, Mark; Martin, Tom

    2008-10-01

    A clear association has been demonstrated between gait stability and falls in the elderly. Integration of wearable computing and human dynamic stability measures into home automation systems may help differentiate fall-prone individuals in a residential environment. The objective of the current study was to evaluate the capability of a pair of electronic textile (e-textile) pants system to assess local dynamic stability and to differentiate motion-impaired elderly from their healthy counterparts. A pair of e-textile pants comprised of numerous e-TAGs at locations corresponding to lower extremity joints was developed to collect acceleration, angular velocity and piezoelectric data. Four motion-impaired elderly together with nine healthy individuals (both young and old) participated in treadmill walking with a motion capture system simultaneously collecting kinematic data. Local dynamic stability, characterized by maximum Lyapunov exponent, was computed based on vertical acceleration and angular velocity at lower extremity joints for the measurements from both e-textile and motion capture systems. Results indicated that the motion-impaired elderly had significantly higher maximum Lyapunov exponents (computed from vertical acceleration data) than healthy individuals at the right ankle and hip joints. In addition, maximum Lyapunov exponents assessed by the motion capture system were found to be significantly higher than those assessed by the e-textile system. Despite the difference between these measurement techniques, attaching accelerometers at the ankle and hip joints was shown to be an effective sensor configuration. It was concluded that the e-textile pants system, via dynamic stability assessment, has the potential to identify motion-impaired elderly.

  4. Median of patient results as a tool for assessment of analytical stability

    DEFF Research Database (Denmark)

    Jørgensen, Lars Mønster; Hansen, Steen Ingemann; Petersen, Per Hyltoft

    2015-01-01

    BACKGROUND: In spite of the well-established external quality assessment and proficiency testing surveys of analytical quality performance in laboratory medicine, a simple tool to monitor the long-term analytical stability as a supplement to the internal control procedures is often needed. METHOD......: Patient data from daily internal control schemes was used for monthly appraisal of the analytical stability. This was accomplished by using the monthly medians of patient results to disclose deviations from analytical stability, and by comparing divergences with the quality specifications for allowable...... analytical bias based on biological variation. RESULTS: Seventy five percent of the twenty analytes achieved on two COBASs INTEGRA 800 instruments performed in accordance with the optimum and with the desirable specifications for bias. DISCUSSION: Patient results applied in analytical quality performance...

  5. Assessment of pipeline stability in the Gulf of Mexico during hurricanes using dynamic analysis

    Directory of Open Access Journals (Sweden)

    Yinghui Tian

    2015-03-01

    Full Text Available Pipelines are the critical link between major offshore oil and gas developments and the mainland. Any inadequate on-bottom stability design could result in disruption and failure, having a devastating impact on the economy and environment. Predicting the stability behavior of offshore pipelines in hurricanes is therefore vital to the assessment of both new design and existing assets. The Gulf of Mexico has a very dense network of pipeline systems constructed on the seabed. During the last two decades, the Gulf of Mexico has experienced a series of strong hurricanes, which have destroyed, disrupted and destabilized many pipelines. This paper first reviews some of these engineering cases. Following that, three case studies are retrospectively simulated using an in-house developed program. The study utilizes the offshore pipeline and hurricane details to conduct a Dynamic Lateral Stability analysis, with the results providing evidence as to the accuracy of the modeling techniques developed.

  6. Advanced controls for stability assessment of solar dynamics space power generation

    Science.gov (United States)

    Momoh, James A.; Anwah, Nnamdi A.

    1995-01-01

    In support of the power requirements for the Space Station Alpha (SSA), a joint program by the U.S. and Russia for a permanently manned space station to be launched into orbit by 1998, a robust control scheme is needed to assure the stability of the rotating machines that will be integrated into the power subsystem. A framework design and systems studies for modeling and analysis is presented. It employs classical d-q axes machine model with voltage/frequency dependent loads. To guarantee that design requirements and necessary trade studies are done, a functional analysis tool CORE is used for the study. This provides us with different control options for stability assessment. Initial studies and recommendations using advanced simulation tools are also presented. The benefits of the stability/control scheme for evaluating future designs and power management are discussed.

  7. Assessments of the kinetic and dynamic transient behavior of sub-critical systems (ADS) in comparison to critical reactor systems

    International Nuclear Information System (INIS)

    Schikorr, W.M.

    2001-01-01

    The neutron kinetic and the reactor dynamic behavior of Accelerator Driven Systems (ADS) is significantly different from those of conventional power reactor systems currently in use for the production of power. It is the objective of this study to examine and to demonstrate the intrinsic differences of the kinetic and dynamic behavior of accelerator driven systems to typical plant transient initiators in comparison to the known, kinetic and dynamic behavior of critical thermal and fast reactor systems. It will be shown that in sub-critical assemblies, changes in reactivity or in the external neutron source strength lead to an asymptotic power level essentially described by the instantaneous power change (i.e. prompt jump). Shutdown of ADS operating at high levels of sub-criticality, (i.e. k eff ∼0.99), without the support of reactivity control systems (such as control or safety rods), may be problematic in case the ability of cooling of the core should be impaired (i.e. loss of coolant flow). In addition, the dynamic behavior of sub-critical systems to typical plant transients such as protected or unprotected loss of flow (LOF) or heat sink (LOH) transients are not necessarily substantially different from the plant dynamic behavior of critical systems if the reactivity feedback coefficients of the ADS design are unfavorable. As expected, the state of sub-criticality and the temperature feedback coefficients, such as Doppler and coolant temperature coefficient, play dominant roles in determining the course and direction of plant transients. Should the combination of these safety coefficients be very unfavorable, not much additional margin in safety may be gained by making a critical system only sub-critical (i.e. k eff ∼0.95). A careful optimization procedure between the selected operating level of sub-criticality, the safety reactivity coefficients and the possible need for additional reactivity control systems seems, therefore, advisable during the early

  8. Investigations on the effect of heater and cooler orientation on the steady state, transient and stability behaviour of single-phase natural circulation in a rectangular loop

    International Nuclear Information System (INIS)

    Vijayan, P.K.; Bhojwani, V.K.; Bade, M.H.; Sharma, M.; Nayak, A.K.; Saha, D.; Sinha, R.K.

    2002-01-01

    An instability demonstration facility has been in operation in the heat transfer laboratory of the Reactor Engineering Div. for the past few years. This report deals with the investigations carried out in this facility so far. The facility is essentially a rectangular loop designed to generate single-phase natural circulation data on the steady state and stability behaviour for different orientations of the heat source and the heat sink. Effect of different heat addition paths (i.e. start-up from rest, power raising from initial stable steady and decay of instability due to power step back) and flow direction on the stability behaviour was also studied. The stability map of the system was generated both by the linear and the nonlinear methods

  9. Assessment of effect of SSSC stabilizer in different control channels on damping inter-area oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Shakarami, M.R., E-mail: shakarami@iust.ac.i [Centre of Excellence for Power System Automation and Operation, Department of Electrical Engineering, Iran University of Science and Technology, Narmak, Tehran (Iran, Islamic Republic of); Kazemi, A. [Centre of Excellence for Power System Automation and Operation, Department of Electrical Engineering, Iran University of Science and Technology, Narmak, Tehran (Iran, Islamic Republic of)

    2011-03-15

    A static synchronous series compensator (SSSC) is one of the series flexible ac transmission system (FACTS) devices that injects a balanced three-phase voltage in quadrature with the transmission line current. There are two channels for controlling of phase and magnitude of the voltage. When the SSSC is used for damping of inter-area oscillations, a SSSC-based stabilizer can be included in both channels. In this paper, the best location and suitable input control signal for SSSC in order to enhance the damping of inter-area oscillations are selected by residue analysis. A method by quadratic mathematic programming has been presented to the design of the stabilizer. By this method, the effect of the stabilizer in both control channels of the SSSC on damping of inter-area oscillations has been assessed. By considering the gain of stabilizer as a criterion, obtained results from studying on a small and a large multi-machine power system show that the stabilizer in the phase control channel is more effective for damping inter-are oscillations.

  10. Topical gel formulation and stability assessment of platelet lysate based on turbidimetric method

    Directory of Open Access Journals (Sweden)

    Soliman Mohammadi Samani

    2015-06-01

    Full Text Available Platelet-rich growth factors have attracted attentions of scientists and clinical practitioners who are involved in wound healing and regenerative medicine extensively, according to their unprecedented potential of promoting and catalyzing healing process. Platelet-rich growth factors are cost-benefit, available and more stable than recombinant human growth factors. These appealing characteristics have converted PRGF to one of the popular candidates for treatment of variety of wounds. According to these valuable properties, we decided to formulate and assess the effect of different excipients on the stability of such valuable protein based formulations. Different excipients have been chosen according to their effective ness on the stability of proteins and their application in other similar formulations. The stabilizing effect of excipients was evaluated by measuring heat-induced aggregation of growth factors by turbidimetric assay. Glycerol, glycine and dextrose were chosen as stabilizing excipients for these formulations. The results show that dextrose has more stabilizing effect on prevention of heat induced aggregation of the platelet lysate growth factors than glycerol and glycine. All of the formulations also contained antioxidant, chelating agents, preservative and carbopol934 in order to form appropriate gel.

  11. Effects of transient bottom water currents and oxygen concentrations on benthic exchange rates as assessed by eddy correlation measurements

    DEFF Research Database (Denmark)

    Holtappels, Moritz; Glud, Ronnie N.; Doris, Daphne

    2013-01-01

    Eddy correlation (EC) measurements in the benthic boundary layer (BBL) allow estimating benthic O2 uptake from a point distant to the sediment surface. This noninvasive approach has clear advantages as it does not disturb natural hydrodynamic conditions, integrates the flux over a large foot-print...... area and allows many repetitive flux measurements. A drawback is, however, that the measured flux in the bottom water is not necessarily equal to the flux across the sediment-water interface. A fundamental assumption of the EC technique is that mean current velocities and mean O2 concentrations...... in the bottom water are in steady state, which is seldom the case in highly dynamic environments like coastal waters. Therefore, it is of great importance to estimate the error introduced by nonsteady state conditions. We investigated two cases of transient conditions. First, the case of transient O2...

  12. GECM-Based Voltage Stability Assessment Using Wide-Area Synchrophasors

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2017-10-01

    Full Text Available Voltage instability is a crucial issue in the secure operation of power grids. Several methods for voltage stability assessment were presented. Some of them are highly computationally intensive, while others are reported not to work properly under all circumstances. This paper proposes a new methodology based on the generator equivalent circuit model (GECM and the phasor measurement unit (PMU technology for online voltage stability monitoring of a power grid. First, the proposed methodology utilizes synchronized phasor (synchrophasor measurements to determine the impedance parameters of a transmission grid by means of the recursive least squares (RLS algorithm. Furthermore, it incorporates the dynamic models of generators to handle the cases with generator reactive power limit violations. After that, an enhanced voltage stability index with GECMs incorporated is developed for reliable and accurate voltage stability assessment. The proposed methodology was first demonstrated on several standard IEEE power systems, and then applied to a practical power system, the Taiwan power (Taipower system. The test results demonstrate the flexibility and effectiveness of the proposed methodology.

  13. Median of patient results as a tool for assessment of analytical stability.

    Science.gov (United States)

    Jørgensen, Lars Mønster; Hansen, Steen Ingemann; Petersen, Per Hyltoft; Sölétormos, György

    2015-06-15

    In spite of the well-established external quality assessment and proficiency testing surveys of analytical quality performance in laboratory medicine, a simple tool to monitor the long-term analytical stability as a supplement to the internal control procedures is often needed. Patient data from daily internal control schemes was used for monthly appraisal of the analytical stability. This was accomplished by using the monthly medians of patient results to disclose deviations from analytical stability, and by comparing divergences with the quality specifications for allowable analytical bias based on biological variation. Seventy five percent of the twenty analytes achieved on two COBASs INTEGRA 800 instruments performed in accordance with the optimum and with the desirable specifications for bias. Patient results applied in analytical quality performance control procedures are the most reliable sources of material as they represent the genuine substance of the measurements and therefore circumvent the problems associated with non-commutable materials in external assessment. Patient medians in the monthly monitoring of analytical stability in laboratory medicine are an inexpensive, simple and reliable tool to monitor the steadiness of the analytical practice. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Assessing fire impacts on the carbon stability of fire-tolerant forests.

    Science.gov (United States)

    Bennett, Lauren T; Bruce, Matthew J; Machunter, Josephine; Kohout, Michele; Krishnaraj, Saravanan Jangammanaidu; Aponte, Cristina

    2017-12-01

    The carbon stability of fire-tolerant forests is often assumed but less frequently assessed, limiting the potential to anticipate threats to forest carbon posed by predicted increases in forest fire activity. Assessing the carbon stability of fire-tolerant forests requires multi-indicator approaches that recognize the myriad ways that fires influence the carbon balance, including combustion, deposition of pyrogenic material, and tree death, post-fire decomposition, recruitment, and growth. Five years after a large-scale wildfire in southeastern Australia, we assessed the impacts of low- and high-severity wildfire, with and without prescribed fire (≤10 yr before), on carbon stocks in multiple pools, and on carbon stability indicators (carbon stock percentages in live trees and in small trees, and carbon stocks in char and fuels) in fire-tolerant eucalypt forests. Relative to unburned forest, high-severity wildfire decreased short-term (five-year) carbon stability by significantly decreasing live tree carbon stocks and percentage stocks in live standing trees (reflecting elevated tree mortality), by increasing the percentage of live tree carbon in small trees (those vulnerable to the next fire), and by potentially increasing the probability of another fire through increased elevated fine fuel loads. In contrast, low-severity wildfire enhanced carbon stability by having negligible effects on aboveground stocks and indicators, and by significantly increasing carbon stocks in char and, in particular, soils, indicating pyrogenic carbon accumulation. Overall, recent preceding prescribed fire did not markedly influence wildfire effects on short-term carbon stability at stand scales. Despite wide confidence intervals around mean stock differences, indicating uncertainty about the magnitude of fire effects in these natural forests, our assessment highlights the need for active management of carbon assets in fire-tolerant eucalypt forests under contemporary fire regimes

  15. Developing integrated performance assessment and forecasting the level of financial and economic enterprise stability

    Directory of Open Access Journals (Sweden)

    Khudyakova T.A.

    2017-01-01

    Full Text Available The article deals with the problem of assessing and forecasting the level of financial and economic enterprise stability through the integrated indicators development. Currently, many enterprises operate under variable external environment, which imposes a strict requirement to consider this uncertainty. For the evaluation, analysis and prediction of the sustainability of the enterprise in the conditions of crisis we believe it possible and necessary to use the apparatus of probability theory and mathematical statistics. This problem solution will improve quantitative assessing the financial and economic stability level, forecasting possible scenarios of the enterprise development and, therefore, based on the proactive management principles and adaptation processes will greatly increase their effective functioning, as well as reduce bankruptcy probability.

  16. Risk Assessment Stability: A Revalidation Study of the Arizona Risk/Needs Assessment Instrument

    Science.gov (United States)

    Schwalbe, Craig S.

    2009-01-01

    The actuarial method is the gold standard for risk assessment in child welfare, juvenile justice, and criminal justice. It produces risk classifications that are highly predictive and that may be robust to sampling error. This article reports a revalidation study of the Arizona Risk/Needs Assessment instrument, an actuarial instrument for juvenile…

  17. Improved Thévenin equivalent methods for real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Østergaard, Jacob

    2016-01-01

    An improved Thévenin equivalent method for real-time voltage stability assessment that uses wide-area information from synchrophasors is proposed. The improvements are a better modeling of the limited synchronous generators, and a processing that anticipates the effect of field current limiters......, before the latter are activated. Several study cases using detailed dynamic simulations of the Nordic test system have been used to assess the performance of the proposed improvements. Their effectiveness is analyzed and, based on the results, their possible application in combination...

  18. Suitability of voltage stability study methods for real-time assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Vancraeyveld, Pieter

    2013-01-01

    This paper analyzes the suitability of existing methods for long-term voltage stability assessment for real-time operation. An overview of the relevant methods is followed with a comparison that takes into account the accuracy, computational efficiency and characteristics when used for security...... assessment. The results enable an evaluation of the run time of each method with respect to the number of inputs. Furthermore, the results assist in identifying which of the methods is most suitable for realtime operation in future power system with production based on fluctuating energy sources....

  19. A Comparison of Balance and Postural Stability Assessment Tools: BESS Versus NeuroCom Balance Manager

    OpenAIRE

    Joliffe, Jamie

    2012-01-01

    Postural stability assessment tools are one of the many ways concussions can be assessed and return to play decisions can be made; two of which are the Balance Error Scoring System (BESS) and force plate technology. OBJECTIVE: Validate the modified BESS used by Utah State University by comparing it to equivalent tests on the NeuroCom Balance Manager System. METHODS: 114 current or previous Utah State football players ranging in age from 18-24. Each athlete conducted a baseline BESS test durin...

  20. The Categorical Stability of Gambling Motives Among Community-Recruited Gamblers: A Longitudinal Assessment.

    Science.gov (United States)

    McGrath, Daniel S; Konkolÿ Thege, Barna

    2018-03-01

    Over the past decade, several motivational models have been proposed to explain the role of motives in gambling disorder. In the model captured by the four-factor Gambling Motives Questionnaire Financial (GMQ-F), gamblers are described as being primarily motivated to gamble for 'coping', 'enhancement', 'social', and 'financial' reasons. Although this model has received significant empirical support; to date, research assessing the role of motives in gambling disorder has been primarily cross-sectional in nature. Thus, the extent to which gambling motives remain stable over time has yet to be explored. In the current study, the stability versus fluidity of self-assessed gambling motives was investigated using the Quinte Longitudinal Study, a longitudinal dataset of gambling behaviour collected over 5 years. Gambling motives of 2795 gamblers were examined over all five annual assessments. The total proportion of gamblers who stayed in the same primary motive category across each of the 5 consecutive assessments was 22%, indicating substantial fluidity in category membership. Substantial movement between categories was seen for each GMQ-F group, as well as an additional group of non-classified motives. Logistic regression analyses suggest that greater resistance to gambling fallacies significantly predicted stability between the baseline assessment and a follow-up 1 year later, but gambling severity did not. Potential limitations in the study design and opportunities for future research are discussed.

  1. Performance Comparison of Adaptive Estimation Techniques for Power System Small-Signal Stability Assessment

    Directory of Open Access Journals (Sweden)

    E. A. Feilat

    2010-12-01

    Full Text Available This paper demonstrates the assessment of the small-signal stability of a single-machine infinite- bus power system under widely varying loading conditions using the concept of synchronizing and damping torques coefficients. The coefficients are calculated from the time responses of the rotor angle, speed, and torque of the synchronous generator. Three adaptive computation algorithms including Kalman filtering, Adaline, and recursive least squares have been compared to estimate the synchronizing and damping torque coefficients. The steady-state performance of the three adaptive techniques is compared with the conventional static least squares technique by conducting computer simulations at different loading conditions. The algorithms are compared to each other in terms of speed of convergence and accuracy. The recursive least squares estimation offers several advantages including significant reduction in computing time and computational complexity. The tendency of an unsupplemented static exciter to degrade the system damping for medium and heavy loading is verified. Consequently, a power system stabilizer whose parameters are adjusted to compensate for variations in the system loading is designed using phase compensation method. The effectiveness of the stabilizer in enhancing the dynamic stability over wide range of operating conditions is verified through the calculation of the synchronizing and damping torque coefficients using recursive least square technique.

  2. The Application of the Accelerated Stability Assessment Program (ASAP) to Quality by Design (QbD) for Drug Product Stability

    OpenAIRE

    Waterman, Kenneth Craig

    2011-01-01

    An isoconversion paradigm, where times in different temperature and humidity-controlled stability chambers are set to provide a fixed degradant level, is shown to compensate for the complex, non-single order kinetics of solid drug products. A humidity-corrected Arrhenius equation provides reliable estimates for temperature and relative humidity effects on degradation rates. A statistical protocol is employed to determine best fits for chemical stability data, which in turn allows for accurate...

  3. IX - MR Control Chart as a Tool in Assessment of the Cast Iron Properties Stability

    Directory of Open Access Journals (Sweden)

    F. Binczyk

    2007-07-01

    Full Text Available The study offers a statistical assessment of the stability of a technological process of melting and pouring low-carbon grey iron assigned for casting of brake discs. Some specific characteristics were presented that should be taken into consideration when statistical methods are used for technology improvement. The stability of the cast iron melting process was evaluated using data read out from the thermal analysis curve and true data, i.e. the results of spectrometric analysis of the chemical composition and measured values of the mechanical properties. The method for assessment of process stability was discussed on the example of carbon content and Brinell hardness. The examined parameters of the technological process of grey iron melting and casting are independent of each other (the results of carbon content determination in successive melts, the results of hardness measurements, etc.. Therefore, for analysis, the IX - MR type charts were chosen, where single measurements of the selected property (n = 1 serve as a measure of location, while a measure of variability are the, so called, Moving Ranges (MR, which are an absolute value of the difference between the two successive measurements.

  4. Nuclear Deterrence in South Asia - an Assessment of Deterrence and Stability in the India-Pakistan Conflict

    OpenAIRE

    Westh, Mark; Juel Giorgio, Maia; Wiegersma, Jakob; Madsen, Tina

    2011-01-01

    This paper offers a coherent assessment of the stability created by nuclear deterrence between India and Pakistan. Our examination posits the neorealist understanding of the stability created by nuclear deterrence in relation to alternative frameworks. To unfold the varying theoretical presuppositions upon which the concept of stability is based, three logically constructed analyses will be undertaken where the theories are explored in relation to empirical data. The Kargil Crisis in 1999 and...

  5. Online Voltage Stability Assessment for Load Areas Based on the Holomorphic Embedding Method

    DEFF Research Database (Denmark)

    Liu, Chengxi; Wang, Bin; Hu, Fengkai

    2018-01-01

    This paper proposes an online steady-state voltage stability assessment scheme to evaluate the proximity to voltage collapse at each bus of a load area. Using a non-iterative holomorphic embedding method (HEM) with a proposed physical germ solution, an accurate loading limit at each load bus can...... be calculated based on online state estimation on the entire load area and a measurement-based equivalent for the external system. The HEM employs a power series to calculate an accurate Power-Voltage (P-V) curve at each load bus and accordingly evaluates the voltage stability margin considering load variations...... and then demonstrated on a load area of the Northeast Power Coordinating Council (NPCC) 48-generator, 140-bus power system....

  6. Learning from anticipated and abnormal plant transients

    International Nuclear Information System (INIS)

    Varnado, B.

    1983-01-01

    A report is given of the American Nuclear Society topical meeting on Anticipated and Abnormal Transients in Light Water Reactors held in Jackson, Wyoming in September 1983. Industry involvement in the evaluation of operating experience, human error contributions, transient management, thermal hydraulic modelling, the role of probabilistic risk assessment and the cost of transient incidents are discussed. (U.K.)

  7. A statistical analysis to assess the maturity and stability of six composts.

    Science.gov (United States)

    Komilis, Dimitrios P; Tziouvaras, Ioannis S

    2009-05-01

    Despite the long-time application of organic waste derived composts to crops, there is still no universally accepted index to assess compost maturity and stability. The research presented in this article investigated the suitability of seven types of seeds for use in germination bioassays to assess the maturity and phytotoxicity of six composts. The composts used in the study were derived from cow manure, sea weeds, olive pulp, poultry manure and municipal solid waste. The seeds used in the germination bioassays were radish, pepper, spinach, tomato, cress, cucumber and lettuce. Data were analyzed with an analysis of variance at two levels and with pair-wise comparisons. The analysis revealed that composts rendered as phytotoxic to one type of seed could enhance the growth of another type of seed. Therefore, germination indices, which ranged from 0% to 262%, were highly dependent on the type of seed used in the germination bioassay. The poultry manure compost was highly phytotoxic to all seeds. At the 99% confidence level, the type of seed and the interaction between the seeds and the composts were found to significantly affect germination. In addition, the stability of composts was assessed by their microbial respiration, which ranged from approximately 4 to 16g O(2)/kg organic matter and from 2.6 to approximately 11g CO(2)-C/kg C, after seven days. Initial average oxygen uptake rates were all less than approximately 0.35g O(2)/kg organic matter/h for all six composts. A high statistically significant correlation coefficient was calculated between the cumulative carbon dioxide production, over a 7-day period, and the radish seed germination index. It appears that a germination bioassay with radish can be a valid test to assess both compost stability and compost phytotoxicity.

  8. Assessing Temporal Stability for Coarse Scale Satellite Moisture Validation in the Maqu Area, Tibet

    Science.gov (United States)

    Bhatti, Haris Akram; Rientjes, Tom; Verhoef, Wouter; Yaseen, Muhammad

    2013-01-01

    This study evaluates if the temporal stability concept is applicable to a time series of satellite soil moisture images so to extend the common procedure of satellite image validation. The area of study is the Maqu area, which is located in the northeastern part of the Tibetan plateau. The network serves validation purposes of coarse scale (25–50 km) satellite soil moisture products and comprises 20 stations with probes installed at depths of 5, 10, 20, 40, 80 cm. The study period is 2009. The temporal stability concept is applied to all five depths of the soil moisture measuring network and to a time series of satellite-based moisture products from the Advance Microwave Scanning Radiometer (AMSR-E). The in-situ network is also assessed by Pearsons's correlation analysis. Assessments by the temporal stability concept proved to be useful and results suggest that probe measurements at 10 cm depth best match to the satellite observations. The Mean Relative Difference plot for satellite pixels shows that a RMSM pixel can be identified but in our case this pixel does not overlay any in-situ station. Also, the RMSM pixel does not overlay any of the Representative Mean Soil Moisture (RMSM) stations of the five probe depths. Pearson's correlation analysis on in-situ measurements suggests that moisture patterns over time are more persistent than over space. Since this study presents first results on the application of the temporal stability concept to a series of satellite images, we recommend further tests to become more conclusive on effectiveness to broaden the procedure of satellite validation. PMID:23959237

  9. Assessment of a general methodology for the analysis of natural circulation stability with water at supercritical pressure

    International Nuclear Information System (INIS)

    Debrah, K. S.

    2014-07-01

    analyses of the actual CIAE natural circulation loop at 25 MPa operating pressure was performed using RELAP5 and newly developed in-house codes (NCLoop for transient and linear analysis). The stability analyses carried out buttressed the find made with the idealized loop on the issue of heat structures, in which the heat structures stabilizes the loop. Transient analysis carried out with RELAP5 and NCLoop agreed very well with the NCLoop linear code with little deviations during short transients. (au)

  10. Transient and 2-Dimensional Shear-Wave Elastography Provide Comparable Assessment of Alcoholic Liver Fibrosis and Cirrhosis.

    Science.gov (United States)

    Thiele, Maja; Detlefsen, Sönke; Sevelsted Møller, Linda; Madsen, Bjørn Stæhr; Fuglsang Hansen, Janne; Fialla, Annette Dam; Trebicka, Jonel; Krag, Aleksander

    2016-01-01

    Alcohol abuse causes half of all deaths from cirrhosis in the West, but few tools are available for noninvasive diagnosis of alcoholic liver disease. We evaluated 2 elastography techniques for diagnosis of alcoholic fibrosis and cirrhosis; liver biopsy with Ishak score and collagen-proportionate area were used as reference. We performed a prospective study of 199 consecutive patients with ongoing or prior alcohol abuse, but without known liver disease. One group of patients had a high pretest probability of cirrhosis because they were identified at hospital liver clinics (in Southern Denmark). The second, lower-risk group, was recruited from municipal alcohol rehabilitation centers and the Danish national public health portal. All subjects underwent same-day transient elastography (FibroScan), 2-dimensional shear wave elastography (Supersonic Aixplorer), and liver biopsy after an overnight fast. Transient elastography and 2-dimensional shear wave elastography identified subjects in each group with significant fibrosis (Ishak score ≥3) and cirrhosis (Ishak score ≥5) with high accuracy (area under the curve ≥0.92). There was no difference in diagnostic accuracy between techniques. The cutoff values for optimal identification of significant fibrosis by transient elastography and 2-dimensional shear wave elastography were 9.6 kPa and 10.2 kPa, and for cirrhosis 19.7 kPa and 16.4 kPa. Negative predictive values were high for both groups, but the positive predictive value for cirrhosis was >66% in the high-risk group vs approximately 50% in the low-risk group. Evidence of alcohol-induced damage to cholangiocytes, but not ongoing alcohol abuse, affected liver stiffness. The collagen-proportionate area correlated with Ishak grades and accurately identified individuals with significant fibrosis and cirrhosis. In a prospective study of individuals at risk for liver fibrosis due to alcohol consumption, we found elastography to be an excellent tool for diagnosing liver

  11. THE TRANSIENT ACCRETING X-RAY PULSAR XTE J1946+274: STABILITY OF X-RAY PROPERTIES AT LOW FLUX AND UPDATED ORBITAL SOLUTION

    Energy Technology Data Exchange (ETDEWEB)

    Marcu-Cheatham, Diana M.; Pottschmidt, Katja [CRESST and Department of Physics, University of Maryland Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250 (United States); Kühnel, Matthias; Müller, Sebastian; Falkner, Sebastian; Kreykenbohm, Ingo [Dr. Karl Remeis-Observatory and ECAP, University Erlangen-Nuremberg, Sternwartstr. 7, Bamberg (Germany); Caballero, Isabel [Laboratoire AIM, CEA/IRFU, CNRS/INSU, Université Paris Diderot, CEA DSM/IRFU/SAp, F-91191 Gif-sur-Yvette (France); Finger, Mark H. [Universities Space Research Association, National Space Science and Technology Center, 320 Sparkman Drive, Huntsville, AL 35805 (United States); Jenke, Peter J. [University of Alabama in Huntsville, 301 Sparkman Drive, Huntsville, AL 35899 (United States); Wilson-Hodge, Colleen A. [Astrophysics Office, ZP 12, NASA Marshall Space Flight Center, Huntsville, AL 35812 (United States); Fürst, Felix [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Grinberg, Victoria [Massachusetts Institute of Technology, Kavli Institute for Astrophysics, Cambridge, MA 02139 (United States); Hemphill, Paul B.; Rothschild, Richard E. [University of California, San Diego, Center for Astrophysics and Space Sciences, 9500 Gilman Drive, La Jolla, CA 92093-0424 (United States); Klochkov, Dmitry [Institut für Astronomie und Astrophysik, Universität Tübingen (IAAT), Sand 1, Tübingen (Germany); Terada, Yukikatsu [Graduate School of Science and Engineering, Saitama University, 255 Simo-Ohkubo, Sakura-ku, Saitama City, Saitama 338-8570 (Japan); and others

    2015-12-10

    We present a timing and spectral analysis of the X-ray pulsar XTE J1946+274 observed with Suzaku during an outburst decline in 2010 October and compare with previous results. XTE J1946+274 is a transient X-ray binary consisting of a Be-type star and a neutron star with a 15.75 s pulse period in a 172 days orbit with 2–3 outbursts per orbit during phases of activity. We improve the orbital solution using data from multiple instruments. The X-ray spectrum can be described by an absorbed Fermi–Dirac cut-off power-law model along with a narrow Fe Kα line at 6.4 keV and a weak Cyclotron Resonance Scattering Feature (CRSF) at ∼35 keV. The Suzaku data are consistent with the previously observed continuum flux versus iron line flux correlation expected from fluorescence emission along the line of sight. However, the observed iron line flux is slightly higher, indicating the possibility of a higher iron abundance or the presence of non-uniform material. We argue that the source most likely has only been observed in the subcritical (non-radiation dominated) state since its pulse profile is stable over all observed luminosities and the energy of the CRSF is approximately the same at the highest (∼5 × 10{sup 37} erg s{sup −1}) and lowest (∼5 × 10{sup 36} erg s{sup −1}) observed 3–60 keV luminosities.

  12. Evaluation of TRIGRS (transient rainfall infiltration and grid-based regional slope-stability analysis)'s predictive skill for hurricane-triggered landslides: A case study in Macon County, North Carolina

    Science.gov (United States)

    Liao, Z.; Hong, Y.; Kirschbaum, D.; Adler, R.F.; Gourley, J.J.; Wooten, R.

    2011-01-01

    The key to advancing the predictability of rainfall-triggered landslides is to use physically based slope-stability models that simulate the transient dynamical response of the subsurface moisture to spatiotemporal variability of rainfall in complex terrains. TRIGRS (transient rainfall infiltration and grid-based regional slope-stability analysis) is a USGS landslide prediction model, coded in Fortran, that accounts for the influences of hydrology, topography, and soil physics on slope stability. In this study, we quantitatively evaluate the spatiotemporal predictability of a Matlab version of TRIGRS (MaTRIGRS) in the Blue Ridge Mountains of Macon County, North Carolina where Hurricanes Ivan triggered widespread landslides in the 2004 hurricane season. High resolution digital elevation model (DEM) data (6-m LiDAR), USGS STATSGO soil database, and NOAA/NWS combined radar and gauge precipitation are used as inputs to the model. A local landslide inventory database from North Carolina Geological Survey is used to evaluate the MaTRIGRS' predictive skill for the landslide locations and timing, identifying predictions within a 120-m radius of observed landslides over the 30-h period of Hurricane Ivan's passage in September 2004. Results show that within a radius of 24 m from the landslide location about 67% of the landslide, observations could be successfully predicted but with a high false alarm ratio (90%). If the radius of observation is extended to 120 m, 98% of the landslides are detected with an 18% false alarm ratio. This study shows that MaTRIGRS demonstrates acceptable spatiotemporal predictive skill for landslide occurrences within a 120-m radius in space and a hurricane-event-duration (h) in time, offering the potential to serve as a landslide warning system in areas where accurate rainfall forecasts and detailed field data are available. The validation can be further improved with additional landslide information including the exact time of failure for each

  13. Assessment of TRAC-PF1/MOD1 against a loss-of-grid transient in Ringhals 4 power plant

    International Nuclear Information System (INIS)

    Sjoberg, A.; Almberger, J.; Sandervag, O.

    1989-07-01

    A loss of grid transient in a three loop Westinghouse PWR has been simulated with the frozen version of TRAC-PF1/MOD1 computer code. The results reveal the capability of the code to qualitatively predict the different pertinent phenomena and the data comparison was quite encouraging. Accurate predictions of the system response required careful determination of the boundary conditions simulating the turbine governor valves and steam dump valves behaviour. An explicit modeling of the steam generator internals was also found to be important for the results. It was also revealed that the pressurizer system including spray and heaters and their operation should be modeled in some detail for proper response. 4 refs., 18 figs

  14. Performance assessment and transient optimization of air precooling in multi-stage solid desiccant air conditioning systems

    International Nuclear Information System (INIS)

    Gadalla, Mohamed; Saghafifar, Mohammad

    2016-01-01

    Highlights: • Studying three two-stage solid desiccant cooling systems using Maisotsenko cooler. • Proposing precooling to improve two-stage desiccant systems’ COP for humid climates. • Performing transient analysis for a two-stage solid desiccant cooler in UAE. • Optimizing daily performance of a two-stage solid desiccant cooler for UAE. - Abstract: Renewable energy is one of the most promising solutions to both energy and global warming crisis. Energy consumption can be minimized considerably by utilizing solar energy in air conditioning systems operation. One of the popular solar air conditioning technologies is desiccant air conditioning. Nonetheless, conventional desiccant air conditioning systems have a relatively low coefficient of performance (COP). In consequence, two-stage desiccant air-conditioning systems are proposed to improve desiccant air conditioning systems’ COP. Moreover, a recently commercialized cooling method named Maisotsenko cooling cycle which is capable of cooling air near to its dew point temperature is considered to be integrated within the proposed multi-stage desiccant cooling systems. In this paper, three new two-stage desiccant air conditioning systems incorporating Maisotsenko cooling cycle are proposed and investigated in details for hot and humid climates such as UAE. Furthermore, air precooling is considered to improve two stage desiccant air conditioning systems’ COP. Moreover, full transient analysis and optimization are carried out in UAE within June–October. The proposed system can minimize the required solar heating during noon time as the ambient air dry bulb temperature rises. Average COP of the system during electricity load peak hours (10:00–14:00) for all five considered and combined months is 1.77. Average rate of heat input required to operate the system and average building cooling load are determined to be 100.3 kW and 46.2 kW, respectively. Therefore, system average COP is computed to be 0.46.

  15. Assessing control of postural stability in community-living older adults using performance-based limits of stability

    DEFF Research Database (Denmark)

    Jbabdi, Myriam; Boissy, Patrice; Hamel, Mathieu

    2008-01-01

    BACKGROUND: Balance disability measurements routinely used to identify fall risks in frail populations have limited value in the early detection of postural stability deficits in community-living older adults. The objectives of the study were to 1) measure performance-based limits of stability (LOS......-session performance variability during multiple trials using the performance-based LOS paradigm. METHODS: Twenty-four healthy community-living older adults (10 men, 14 women) aged between 62 to 85 (mean age +/- sd, 71.5 +/- 6 yrs) participated in the study. Subjects' performance-based LOS were established by asking...

  16. Long-term process of reforming the economy of Republic of Serbia in order to achieve macroeconomic stabilization: From transient changes to the activist approach

    Directory of Open Access Journals (Sweden)

    Gavrilović Milica

    2015-01-01

    Full Text Available In today's economy, which is burdened by problems such as non-productive economy, high unemployment rates, constant inflationary pressures, great attention is paid to the interaction of monetary and fiscal policies in order to achieve macroeconomic stability. There is no universal model of economic policy even in countries around the world, nor in the Serbian economy, and policy makers are looking for the optimal design of monetary and fiscal strategies and their synchronization with other non-negligible specific economic policy objectives (in terms of balance of payments, objectives related to foreign currency course, the distribution of income, implemented stage of market reforms of the nineties, and then phase of reforms in the first decade of the 21st century. How good coordination of monetary and fiscal measures can be no qualitative basis, or as it is not possible to reconstruct and degrade previous economic structure, and that there is no definition of the new strategy, and continued the process of reforming and in the period from the time of deepening global financial crisis in 2008 . The Republic of Serbia, a country whose economy in the long process of reforming, seeks better use of comparative advantages, encouraging production and employment, adequate planning and allocation of available resources of its own and charge, absorption of new technologies, intensifying exports, encouraging investment, and with a constant potential danger which increase the vulnerability of small economies. The solid foundations of macroeconomic stability and discipline must be in production, proper allocation of resources, which will run the economy, and then increase the employment rate, and therefore national income. of crucial importance of good projections of macroeconomic aggregates, because of them depend on public revenue and public expenditure.

  17. Slope stability and rockfall assessment of volcanic tuffs using RPAS with 2-D FEM slope modelling

    Science.gov (United States)

    Török, Ákos; Barsi, Árpád; Bögöly, Gyula; Lovas, Tamás; Somogyi, Árpád; Görög, Péter

    2018-02-01

    Steep, hardly accessible cliffs of rhyolite tuff in NE Hungary are prone to rockfalls, endangering visitors of a castle. Remote sensing techniques were employed to obtain data on terrain morphology and to provide slope geometry for assessing the stability of these rock walls. A RPAS (Remotely Piloted Aircraft System) was used to collect images which were processed by Pix4D mapper (structure from motion technology) to generate a point cloud and mesh. The georeferencing was made by Global Navigation Satellite System (GNSS) with the use of seven ground control points. The obtained digital surface model (DSM) was processed (vegetation removal) and the derived digital terrain model (DTM) allowed cross sections to be drawn and a joint system to be detected. Joint and discontinuity system was also verified by field measurements. On-site tests as well as laboratory tests provided additional engineering geological data for slope modelling. Stability of cliffs was assessed by 2-D FEM (finite element method). Global analyses of cross sections show that weak intercalating tuff layers may serve as potential slip surfaces. However, at present the greatest hazard is related to planar failure along ENE-WSW joints and to wedge failure. The paper demonstrates that RPAS is a rapid and useful tool for generating a reliable terrain model of hardly accessible cliff faces. It also emphasizes the efficiency of RPAS in rockfall hazard assessment in comparison with other remote sensing techniques such as terrestrial laser scanning (TLS).

  18. Slope stability and rockfall assessment of volcanic tuffs using RPAS with 2-D FEM slope modelling

    Directory of Open Access Journals (Sweden)

    Á. Török

    2018-02-01

    Full Text Available Steep, hardly accessible cliffs of rhyolite tuff in NE Hungary are prone to rockfalls, endangering visitors of a castle. Remote sensing techniques were employed to obtain data on terrain morphology and to provide slope geometry for assessing the stability of these rock walls. A RPAS (Remotely Piloted Aircraft System was used to collect images which were processed by Pix4D mapper (structure from motion technology to generate a point cloud and mesh. The georeferencing was made by Global Navigation Satellite System (GNSS with the use of seven ground control points. The obtained digital surface model (DSM was processed (vegetation removal and the derived digital terrain model (DTM allowed cross sections to be drawn and a joint system to be detected. Joint and discontinuity system was also verified by field measurements. On-site tests as well as laboratory tests provided additional engineering geological data for slope modelling. Stability of cliffs was assessed by 2-D FEM (finite element method. Global analyses of cross sections show that weak intercalating tuff layers may serve as potential slip surfaces. However, at present the greatest hazard is related to planar failure along ENE–WSW joints and to wedge failure. The paper demonstrates that RPAS is a rapid and useful tool for generating a reliable terrain model of hardly accessible cliff faces. It also emphasizes the efficiency of RPAS in rockfall hazard assessment in comparison with other remote sensing techniques such as terrestrial laser scanning (TLS.

  19. Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lin, Yashen [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Purba, Victor [University of Minnesota; Dhople, Sairaj [University of Minnesota

    2017-09-28

    From the inception of power systems, synchronous machines have acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, power electronics interfaces are playing a growing role as they are the primary interface for several types of renewable energy sources and storage technologies. As the role of power electronics in systems continues to grow, it is crucial to investigate the properties of bulk power systems in low inertia settings. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. Furthermore, the inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings and, hence, differing levels of inertia. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the interaction between the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

  20. Assessment of genetic stability in micropropagules of Jatropha curcas genotypes by RAPD and AFLP analysis

    KAUST Repository

    Sharma, Sweta K.

    2011-07-01

    Jatropha curcas (Euphorbiaceae), a drought resistant non edible oil yielding plant, has acquired significant importance as an alternative renewable energy source. Low and inconsistent yields found in field plantations prompted for identification of high yielding clones and their large scale multiplication by vegetative propagation to obtain true to type plants. In the current investigation plantlets of J. curcas generated by axillary bud proliferation (micropropagation) using nodal segments obtained from selected high yielding genotypes were assessed for their genetic stability using Randomly Amplified Polymorphic DNA (RAPD) and Amplified Fragment Length Polymorphism (AFLP) analyses. For RAPD analysis, 21 out of 52 arbitrary decamer primers screened gave clear reproducible bands. In the micropropagated plantlets obtained from the 2nd sub-culture, 4 out of a total of 177 bands scored were polymorphic, but in the 8th and 16th sub-cultures (culture cycle) no polymorphisms were detected. AFLP analysis revealed 0.63%, 0% and 0% polymorphism in the 2nd, 8th and 16th generations, respectively. When different genotypes, viz. IC 56557 16, IC 56557 34 and IC 56557 13, were assessed by AFLP, 0%, 0.31% and 0.47% polymorphisms were found, respectively, indicating a difference in genetic stability among the different genotypes. To the best of our knowledge this is the first report on assessment of genetic stability of micropropagated plantlets in J. curcas and suggests that axillary shoot proliferation can safely be used as an efficient micropropagation method for mass propagation of J. curcas. © 2011 Elsevier B.V.

  1. Tactile pavement for guiding walking direction: An assessment of heading direction and gait stability.

    Science.gov (United States)

    Pluijter, Nanda; de Wit, Lieke P W; Bruijn, Sjoerd M; Plaisier, Myrthe A

    2015-10-01

    For maintaining heading direction while walking we heavily rely on vision. Therefore, walking in the absence of vision or with visual attention directed elsewhere potentially leads to dangerous situations. Here we investigated whether tactile information from the feet can be used as a (partial) substitute for vision in maintaining a stable heading direction. If so, participants should be better able to keep a constant heading direction on tactile pavement that indicates directionality than on regular flat pavement. However, such a pavement may also be destabilizing. Thus we asked participants to walk straight ahead on regular pavement, and on tactile pavement (tiles with ridges along the walking direction) while varying the amount of vision. We assessed the effects of the type of pavement as well as the amount of vision on the variability of the heading direction as well as gait stability. Both of these measures were calculated from accelerations and angular velocities recorded from a smartphone attached to the participants trunk. Results showed that on tactile pavement participants had a less variations in their heading direction than on regular pavement. The drawback, however, was that the tactile pavement used in this study decreased gait stability. In sum, tactile pavement can be used as a partial substitute for vision in maintaining heading direction, but it can also decrease gait stability. Future work should focus on designing tactile pavement that does provided directional clues, but is less destabilizing. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Hazard assessment of the stability of a cavern roof along the coastline

    Science.gov (United States)

    Reina, A.; Lollino, P.

    2009-04-01

    This work concerns the hazard assessment about the stability of a large shallow depth cavern, located along the coastline rocky sector of Polignano town (Apulia, Southern Italy) under an intensely urbanised area. This cavern, which lies at the sea level, has been created by a prolonged process of sea erosion within a rock mass formed of a lower stratified limestone mass and an upper Gravina Calcarenite mass. The thickness of the cavern roof, which has a dome shape, is less than 10 metres in the centre. Important buildings, as hotels and private houses, are located just above the top of the roof. Erosion processes have been observed to be still active along the whole cavern due to climate factors and, in particular, to sea salt weathering and sea spray effects. In 2007 a large calcarenite block, 3 m large, fell down from the cavern roof and consequently a field investigation campaign was carried out for a rational stabilization plan in order to understand the current stability conditions of the roof and the potential failure mechanism. Therefore, a thorough geo-structural survey has firstly been carried out, together with laboratory and in-situ testing for measuring the physical and mechanical properties of the calcarenite rock and of the corresponding joints. A monitoring system has also been planned and installed in order to measure the erosional rate and the block displacements in the cavern.

  3. Captopril 25 mg tablets stability assessment in different primary packing materials

    Directory of Open Access Journals (Sweden)

    Flávia Costa Mendes Paiva

    2017-11-01

    Full Text Available Introduction: Packaging is used to provide protection and information, from the production to the administration of a formulation. It is essential to define the primary packaging, for keeping the therapeutic efficacy of drugs, safety of users and for protecting drugs from instability. Objectives: The main objective of this study was to assess the stability of captopril 25 mg tablets in different primary packaging materials. Method: The characterization (IR, DSC and physical tests of the packaging materials used for captopril was carried out prior to the manufacture of tablets. Tablets were also characterized by physical-chemical analysis, comparative dissolution profile and stability studies. Results: The characterization of packaging materials was crucial for understanding the behavior of captopril when packed in each material. Materials with significant barrier, as blisters PVC/PVdC 90 g.m-² and hard aluminum and PVC/PE/PVdC and hard aluminum showed satisfactory results in a second stage, S2. On the contrary, lower barrier materials as blisters PVC/PVdC 40 g.m-² and hard aluminum did not present dissolution analysis S2. Conclusions: The aluminum strip presented the best results. And the batch in glass bottle, although packaged in excellent material, was disapproved in accelerated stability.

  4. ASSESSING CLIMATE CHANGE IMPACTS ON THE STABILITY OF SMALL TIDAL INLETS: Part 2- DATA RICH ENVIRONMENTS.

    Science.gov (United States)

    Duong, Trang Minh; Ranasinghe, Roshanka; Thatcher, Marcus; Mahanama, Sarith; Wang, Zheng Bing; Dissanayake, Pushpa Kumara; Hemer, Mark; Luijendijk, Arjen; Bamunawala, Janaka; Roelvink, Dano; Walstra, Dirkjan

    2018-01-01

    Climate change (CC) is likely to affect the thousands of bar-built or barrier estuaries (here referred to as Small tidal inlets - STIs) around the world. Any such CC impacts on the stability of STIs, which governs the dynamics of STIs as well as that of the inlet-adjacent coastline, can result in significant socio-economic consequences due to the heavy human utilisation of these systems and their surrounds. This article demonstrates the application of a process based snap-shot modelling approach, using the coastal morphodynamic model Delft3D , to 3 case study sites representing the 3 main STI types; Permanently open, locationally stable inlets (Type 1), Permanently open, alongshore migrating inlets (Type 2) and Seasonally/Intermittently open, locationally stable inlets (Type 3). The 3 case study sites (Negombo lagoon - Type 1, Kalutara lagoon - Type 2, and Maha Oya river - Type 3) are all located along the southwest coast of Sri Lanka. After successful hydrodynamic and morphodynamic model validation at the 3 case study sites, CC impact assessment are undertaken for a high end greenhouse gas emission scenario. Future CC modified wave and riverflow conditions are derived from a regional scale application of spectral wave models (WaveWatch III and SWAN) and catchment scale applications of a hydrologic model (CLSM) respectively, both of which are forced with IPCC Global Climate Model output dynamically downscaled to ~ 50 km resolution over the study area with the stretched grid Conformal Cubic Atmospheric Model CCAM. Results show that while all 3 case study STIs will experience significant CC driven variations in their level of stability, none of them will change Type by the year 2100. Specifically, the level of stability of the Type 1 inlet will decrease from 'Good' to 'Fair to poor' by 2100, while the level of (locational) stability of the Type 2 inlet will also decrease with a doubling of the annual migration distance. Conversely, the stability of the Type 3 inlet

  5. Joint analysis of epistemic and aleatory uncertainty in stability analysis for geo-hazard assessments

    Science.gov (United States)

    Rohmer, Jeremy; Verdel, Thierry

    2017-04-01

    Uncertainty analysis is an unavoidable task of stability analysis of any geotechnical systems. Such analysis usually relies on the safety factor SF (if SF is below some specified threshold), the failure is possible). The objective of the stability analysis is then to estimate the failure probability P for SF to be below the specified threshold. When dealing with uncertainties, two facets should be considered as outlined by several authors in the domain of geotechnics, namely "aleatoric uncertainty" (also named "randomness" or "intrinsic variability") and "epistemic uncertainty" (i.e. when facing "vague, incomplete or imprecise information" such as limited databases and observations or "imperfect" modelling). The benefits of separating both facets of uncertainty can be seen from a risk management perspective because: - Aleatoric uncertainty, being a property of the system under study, cannot be reduced. However, practical actions can be taken to circumvent the potentially dangerous effects of such variability; - Epistemic uncertainty, being due to the incomplete/imprecise nature of available information, can be reduced by e.g., increasing the number of tests (lab or in site survey), improving the measurement methods or evaluating calculation procedure with model tests, confronting more information sources (expert opinions, data from literature, etc.). Uncertainty treatment in stability analysis usually restricts to the probabilistic framework to represent both facets of uncertainty. Yet, in the domain of geo-hazard assessments (like landslides, mine pillar collapse, rockfalls, etc.), the validity of this approach can be debatable. In the present communication, we propose to review the major criticisms available in the literature against the systematic use of probability in situations of high degree of uncertainty. On this basis, the feasibility of using a more flexible uncertainty representation tool is then investigated, namely Possibility distributions (e

  6. Advanced Techniques for Assessment of Postural and Locomotor Ataxia, Spatial Orientation, and Gaze Stability

    Science.gov (United States)

    Wall, Conrad., III

    1999-01-01

    In addition to adapting to microgravity, major neurovestibular problems of space flight include postflight difficulties with standing, walking, turning corners, and other activities that require stable upright posture and gaze stability. These difficulties inhibit astronauts' ability to stand or escape from their vehicle during emergencies. The long-ter7n goal of the NSBRI is the development of countermeasures to ameliorate the effects of long duration space flight. These countermeasures must be tested with valid and reliable tools. This project aims to develop quantitative, parametric approaches for assessing gaze stability and spatial orientation during normal gait and when gait is perturbed. Two of this year's most important findings concern head fixation distance and ideal trajectory analysis. During a normal cycle of walking the head moves up and down linearly. A simultaneous angular pitching motion of the head keeps it aligned toward an imaginary point in space at a distance of about one meter in front of a subject and along the line of march. This distance is called the head fixation distance. Head fixation distance provides the fundamental framework necessary for understanding the functional significance of the vestibular reflexes that couple head motion to eye motion. This framework facilitates the intelligent design of counter-measures for the effects of exposure to microgravity upon the vestibular ocular reflexes. Ideal trajectory analysis is a simple candidate countermeasure based upon quantifying body sway during repeated up and down stair stepping. It provides one number that estimates the body sway deviation from an ideal sinusoidal body sway trajectory normalized on the subject's height. This concept has been developed with NSBRI funding in less than one year. These findings are explained in more detail below. Compared to assessments of the vestibuo-ocular reflex, analysis of vestibular effects on locomotor function is relatively less well developed

  7. Assessment of Submarine Slope Stability on the Continental Margin off SW Taiwan

    Science.gov (United States)

    Hsu, Huai-Houh; Dong, Jia-Jyun; Cheng, Win-Bin; Su, Chih-Chieh

    2017-04-01

    The abundant gas hydrate reservoirs are distributed in the southwest (SW) off Taiwan. To explore this new energy, geological methods were systematically used and mainly emphasized on the storage potential evaluation. On the other hand, the correlation between gas hydrate dissociation and submarine slope stability is also an important issue. In this study, three submarine profiles on the active and passive continental margin were selected and assessed their slope stabilities by considering two influence factors (seismic forces and number of sedimentary layers). The gravity corers obtained from these three sites (Xiaoliuqiu, Yuan-An Ridge, and Pointer Ridge) to conduct soil laboratory tests. The physical property tests and isotropically consolidated undrained (CIU) triaxial tests were carried out to establish reference properties and shear strength parameters. Before the stability analysis is performed, it is also necessary to construct the seabed profile. For each submarine profile, data from P-waves and from S-waves generated by P-S conversion on reflection from airgun shots recorded along one line of ocean bottom seismometers were used to construct 2-D velocity sections. The seabed strata could be simplified to be only one sedimentary layer or to be multilayer in accordance with the velocity structure profile. Results show the safety factors (FS) of stability analysis are obviously different in considering the number of sedimentary layers, especially for a very thin layer of sediments on a steep slope. The simplified strata condition which treated all seabed strata as only one sedimentary layer might result in the FS lower than 1 and the slope was in an unstable state. On the contrary, the FS could be higher than 10 in a multilayer condition.

  8. Assessing the Benefits of Global Climate Stabilization Within an Integrated Modeling Framework

    Science.gov (United States)

    Beach, R. H.

    2015-12-01

    Increasing atmospheric carbon dioxide levels, higher temperatures, altered precipitation patterns, and other climate change impacts have already begun to affect US agriculture and forestry, with impacts expected to become more substantial in the future. There have been a number of studies of climate change impacts on agriculture or forestry. However, relatively few studies explore climate change impacts on both agriculture and forests simultaneously, including the interactions between alternative land uses and implications for market outcomes. Additionally, there is a lack of detailed analyses of the effects of stabilization scenarios relative to unabated emissions scenarios. Such analyses are important for developing estimates of the benefits of those stabilization scenarios, which can play a vital role in assessing tradeoffs associated with allocating resources across alternative mitigation and adaptation activities. We provide an analysis of the potential benefits of global climate change mitigation for US agriculture and forestry through 2100, accounting for landowner decisions regarding land use, crop mix, and management practices. The analytic approach involves a combination of climate models, a crop process model (EPIC), a dynamic vegetation model used for forests (MC1), and an economic model of the US forestry and agricultural sector (FASOM-GHG). We find substantial impacts on productivity, commodity markets, and consumer and producer welfare for the stabilization scenario relative to unabated climate change, though the magnitude and direction of impacts vary across regions and commodities. Although there is variability in welfare impacts across climate simulations, we find positive net benefits from stabilization in all cases, with cumulative impacts ranging from 32.7 billion to 54.5 billion over the period 2015-2100. Our estimates contribute to the literature on potential benefits of GHG mitigation and can help inform policy decisions weighing alternative

  9. Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

    Science.gov (United States)

    Hong, Christine; Truong, Peter; Song, Ha Na; Wu, Benjamin M; Moon, Won

    2011-11-01

    To assess the mechanical stability of a newly revised orthodontic mini-implant design (N2) compared with a design introduced in Part 1 of the study (N1) and the most widely-used commercially-available design (CA). To evaluate the mean buccal bone thickness of maxillary and mandibular posterior teeth using cone-beam computed tomography (CBCT). From the CBCT scans of 20 patients, six tomographic cross-sections were generated for each tooth. Buccal bone thickness was measured from the most convex point on the bone to the root surface. CA (1.5 mm in diameter and 6 mm in length), N1, and N2 (shorter and narrower than N1) were inserted in simulated bone with cortical and trabecular bone layers. Mechanical stability was compared in vitro through torque and lateral displacement tests. The bone thickness ranged from 2.26 to 3.88 mm. Maximum insertion torque was decreased significantly in N2 compared to N1. However, force levels for all displacement distances and torque ratio were the highest in N2, followed by N1 and CA (α = .05). Both torque and lateral displacement tests highlighted the enhanced stability of N2 compared with CA. Design revisions to N1 effectively mitigated N1's high insertion torque and thus potentially reduced microdamage to the surrounding bone. The N2 design is promising as evidenced by enhanced stability and high mechanical efficiency. Moreover, N2 is not limited to placement in interradicular spaces and has the capacity to be placed in the buccal bone superficial to the root surface with diminished risk of endangering nearby anatomic structures during placement and treatment.

  10. VALIDATING A COMPUTER-BASED TECHNIQUE FOR ASSESSING STABILITY TO FAILURE STRESS

    Directory of Open Access Journals (Sweden)

    I. F. Arshava

    2013-03-01

    Full Text Available An upsurge of interest in the implicit personality assessment, currently observed both in personality psycho-diagnostics and in experimental studies of social attitudes and prejudices, signals the shifting of researchers’ attention from de?ning between-person personality taxonomy to specifying comprehensive within-person processes, the dynamics of which can be captured at the level of an individual case. This research examines the possibility of the implicit assessment of the individual’s stability vs. susceptibility to failure stress by comparing the degrees of ef?cacy in the voluntary self-regulation of a computer-simulated information-processing activity under different conditions (patent of Ukraine № 91842, issued in 2010. By exposing two groups of participants (university undergraduates to processing the information, the scope of which exceeds the human short-term memory capacity at one of the stages of the modeled activity an unexpected and unavoidable failure is elicited. The participants who retain stability of their self-regulation behavior after having been exposed to failure, i.e. who keep processing information as effectively as they did prior to failure, are claimed to retain homeostasis and thus possess emotional stability. Those, who loose homeostasis after failure and display lower standards of self-regulation behavior, are considered to be susceptible to stress. The validity of the suggested type of the implicit diagnostics was empirically tested by clustering (K-means algorithm two samples of the participants on the  properties of their self-regulation behavior and testing between-cluster differences by a set of the explicitly assessed variables: Action control ef?cacy (Kuhl, 2001, preferred strategies of Coping with Stressful Situations (Endler, Parker, 1990,  Purpose-in-Life orientation (a Russian version of the test by Crumbaugh and Maholick, modi?ed by D.Leontiev, 1992, Psychological Well-being (Ryff, 1989

  11. Assessment of postural stability in overweight and obese middle-aged women

    Directory of Open Access Journals (Sweden)

    Zuzana Kováčiková

    2014-09-01

    Full Text Available Background: Obesity and overweight are defined as abnormal or excessive fat accumulation and are associated with balance disorders. Objective: To assess the postural stability in a natural stance in overweight and obese women based on center of pressure (CoP velocity in the anterior-posterior (AP and medial-lateral (ML directions. Methods: A total of 102 women categorized according to body mass index into normal weight, overweight and obese categories underwent a measurement of quiet standing with their eyes open (EO and with their eyes closed (EC. Postural stability was assessed with a force platform. The mean CoP velocity was evaluated in both directions. Results: In the AP direction under EO conditions, obese women swayed significantly faster than normal weight women (1.01 cm/s and 0.80 cm/s. In the ML direction, a higher CoP velocity was observed in normal weight women than in obese women (0.52 cm/s and 0.41 cm/s. Under EC conditions in the AP direction, obese women swayed significantly faster than normal weight women (1.29 cm/s and 0.97 cm/s. In the ML direction, a higher CoP velocity was observed in normal weight women than in obese women (0.65 cm/s and 0.48 cm/s. Conclusions: Results suggest a negative impact of obesity on postural stability in the AP direction. In the ML direction, obese women were more stable than normal weight women, probably due to enlargement of the support base in a natural stance.

  12. Nuclear power plant transients: where are we

    International Nuclear Information System (INIS)

    Majumdar, D.

    1984-05-01

    This document is in part a postconference review and summary of the American Nuclear Society sponsored Anticipated and Abnormal Plant Transients in Light Water Reactors Conference held in Jackson, Wyoming, September 26-29, 1983, and in part a reflection upon the issues of plant transients and their impact on the viability of nuclear power. This document discusses state-of-the-art knowledge, deficiencies, and future directions in the plant transients area as seen through this conference. It describes briefly what was reported in this conference, emphasizes areas where it is felt there is confidence in the nuclear industry, and also discusses where the experts did not have a consensus. Areas covered in the document include major issues in operational transients, transient management, transient events experience base, the status of the analytical tools and their capabilities, probabilistic risk assessment applications in operational transients, and human factors impact on plant transients management

  13. Assessment of Physical Stability and Antioxidant Activity of Polysiloxane Polyalkyl Polyether Copolymer-Based Creams

    Directory of Open Access Journals (Sweden)

    Atif Ali

    2013-01-01

    Full Text Available The purpose of the present work was to investigate the changes on physical stability (color, creaming, liquefaction, pH, conductivity, centrifugation, viscosity and rheological parameters by non-ionic surfactant polysiloxane polyalkyl polyether copolymer based creams following inclusion of plant extract containing phenolic compounds. The antioxidant activity of the plant extract alone and after addition in the cream was assessed using the stable free radical 1,1-diphenyl-2-picrylhydrazyl (DPPH assay. Physical stability was assessed by submitting the creams to storage at 8°C, 25°C, 40°C, and at 40°C with 70% RH (relative humidity for a period of two months. Physical characteristics of polysiloxane polyalkyl polyether copolymer based creams, that is, color, creaming, liquefaction, centrifugation and pH were noted at various intervals for 2 months. The viscosities and rheological behavior of creams were determined using a rotational rheometer. Data were analyzed by using Brookfield Software Rheocalc version (2.6 with IPC Paste and Power Law (PL math models. Cream with plant extract showed pseudo plastic behaviour with decreasing on viscosity. The Acacia nilotica (AN extract alone and the cream containing this extract showed great antioxidant and free radical scavenging activities. Power Law and IPC analysis were found to fit all the rheograms.

  14. Assessment of dental implant stability by means of the electromechanical impedance method

    International Nuclear Information System (INIS)

    Boemio, Giovanni; Rizzo, Piervincenzo; Nardo, Luigi De

    2011-01-01

    Implant stability is a prerequisite for functional recovery in load-bearing prostheses. Robust, reliable and noninvasive methods to assess the bone interface of dental and orthopedic implants are increasingly demanded for clinical diagnosis and direct prognosis. In this paper, a study of the feasibility of a noninvasive method based on electromechanical impedance (EMI) to assess dental prostheses stability is presented. Two different dental screws were entrenched in polyurethane foams (Sawbones ® ) and immersed in a solution of nitric acid to allow material degradation, inversely simulating a bone healing process. This process was monitored by bonding a piezoceramic transducer (PZT) to the implant and measuring the admittance of the PZT over time. It was found that the PZT's conductance and the statistical features associated with its analysis were sensitive to the degradation of the foams and can be correlated to the Sawbones mechanical properties. The present study shows promising results and may pave the road towards an innovative approach for the noninvasive monitoring of implanted prostheses

  15. Code assessment and modelling for Design Basis Accident analysis of the European Sodium Fast Reactor design. Part II: Optimised core and representative transients analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lazaro, A., E-mail: aulach@iqn.upv.es [JRC-IET European Commission, Westerduinweg 3, PO BOX 2, 1755 ZG Petten (Netherlands); Schikorr, M. [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Mikityuk, K. [PSI, Paul Scherrer Institut, 5232 Villigen (Switzerland); Ammirabile, L. [JRC-IET European Commission, Westerduinweg 3, PO BOX 2, 1755 ZG Petten (Netherlands); Bandini, G. [ENEA, Via Martiri di Monte Sole 4, 40129 Bologna (Italy); Darmet, G.; Schmitt, D. [EDF, 1 Avenue du Général de Gaulle, 92141 Clamart (France); Dufour, Ph.; Tosello, A. [CEA, St. Paul lez Durance, 13108 Cadarache (France); Gallego, E.; Jimenez, G. [UPM, José Gutiérrez Abascal, 2, 28006 Madrid (Spain); Bubelis, E.; Ponomarev, A.; Kruessmann, R.; Struwe, D. [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Stempniewicz, M. [NRG, Utrechtseweg 310, P.O. Box-9034, 6800 ES Arnhem (Netherlands)

    2014-10-01

    Highlights: • Benchmarked models have been applied for the analysis of DBA transients of the ESFR design. • Two system codes are able to simulate the behavior of the system beyond sodium boiling. • The optimization of the core design and its influence in the transients’ evolution is described. • The analysis has identified peak values and grace times for the protection system design. - Abstract: The new reactor concepts proposed in the Generation IV International Forum require the development and validation of computational tools able to assess their safety performance. In the first part of this paper the models of the ESFR design developed by several organisations in the framework of the CP-ESFR project were presented and their reliability validated via a benchmarking exercise. This second part of the paper includes the application of those tools for the analysis of design basis accident (DBC) scenarios of the reference design. Further, this paper also introduces the main features of the core optimisation process carried out within the project with the objective to enhance the core safety performance through the reduction of the positive coolant density reactivity effect. The influence of this optimised core design on the reactor safety performance during the previously analysed transients is also discussed. The conclusion provides an overview of the work performed by the partners involved in the project towards the development and enhancement of computational tools specifically tailored to the evaluation of the safety performance of the Generation IV innovative nuclear reactor designs.

  16. Code assessment and modelling for Design Basis Accident analysis of the European Sodium Fast Reactor design. Part II: Optimised core and representative transients analysis

    International Nuclear Information System (INIS)

    Lazaro, A.; Schikorr, M.; Mikityuk, K.; Ammirabile, L.; Bandini, G.; Darmet, G.; Schmitt, D.; Dufour, Ph.; Tosello, A.; Gallego, E.; Jimenez, G.; Bubelis, E.; Ponomarev, A.; Kruessmann, R.; Struwe, D.; Stempniewicz, M.

    2014-01-01

    Highlights: • Benchmarked models have been applied for the analysis of DBA transients of the ESFR design. • Two system codes are able to simulate the behavior of the system beyond sodium boiling. • The optimization of the core design and its influence in the transients’ evolution is described. • The analysis has identified peak values and grace times for the protection system design. - Abstract: The new reactor concepts proposed in the Generation IV International Forum require the development and validation of computational tools able to assess their safety performance. In the first part of this paper the models of the ESFR design developed by several organisations in the framework of the CP-ESFR project were presented and their reliability validated via a benchmarking exercise. This second part of the paper includes the application of those tools for the analysis of design basis accident (DBC) scenarios of the reference design. Further, this paper also introduces the main features of the core optimisation process carried out within the project with the objective to enhance the core safety performance through the reduction of the positive coolant density reactivity effect. The influence of this optimised core design on the reactor safety performance during the previously analysed transients is also discussed. The conclusion provides an overview of the work performed by the partners involved in the project towards the development and enhancement of computational tools specifically tailored to the evaluation of the safety performance of the Generation IV innovative nuclear reactor designs

  17. Assessment of Hypercoagulation State in Patients with Embolic Cerebrovascular or Transient Ischemic Attack and Patent Foramen Ovale

    Directory of Open Access Journals (Sweden)

    D Nikfarjam

    2010-03-01

    Full Text Available Background: Patent foramen ovale (PFO causes a right-to-left shunt in about a quarter of normal population. Hypercoagulation may be a risk factor for embolic cerebrovascular accidents (CVA in these patients by paradoxical emboli. In this study, we checked hypercoagulation states in the embolic CVA patients with PFO. Methods: In a cross- sectional study, 40 patients with CVA or transient ischemic attack ( TIA and PFO participated in the study. Serum level of Homocystein, lupus anticoagulant screening test, Factor V leiden, Anti Cardiolipin Antibody (ACLA (IgG, IgM , Anti- thrombin III, protein C, protein S,Anti B2 glycoprotein1 and platelet count were checked in all patients. The data were analyzed using the statistical package for social science series (SPSS 15.0 and descriptive statistical method.Results: The mean age was 42.4± 12.1. Seventeen (42.5% patients were females. Twenty- two (55% cases were diagnosed as having CVA and the others as TIA. Three (7.5% of the patients were diabetic and 8 (20% had a history of different stages of hypertension. Hyperlipidemia was detected in 6 (15% patients and according to the laboratory data none had any signs of hypercoagulation.Conclusion: According to the present study, hypercoagulation as a cofactor in CVA patients with PFO did not seem to be a direct risk factor for embolic CVA at least any higher than for normal population.

  18. Assessing anthropogenic impacts on limited water resources under semi-arid conditions: three-dimensional transient regional modelling in Jordan

    Science.gov (United States)

    Rödiger, Tino; Magri, Fabien; Geyer, Stefan; Morandage, Shehan Tharaka; Ali Subah, H. E.; Alraggad, Marwan; Siebert, Christian

    2017-11-01

    Both increasing aridity and population growth strongly stress freshwater resources in semi-arid areas such as Jordan. The country's second largest governorate, Irbid, with over 1 million inhabitants, is already suffering from an annual water deficit of 25 million cubic meters (MCM). The population is expected to double within the next 20 years. Even without the large number of refugees from Syria, the deficit will likely increase to more then 50 MCM per year by 2035 The Governorate's exclusive resource is groundwater, abstracted by the extensive Al Arab and Kufr Asad well fields. This study presents the first three-dimensional transient regional groundwater flow model of the entire Wadi al Arab to answer important questions regarding the dynamic quality and availability of water within the catchment. Emphasis is given to the calculation and validation of the dynamic groundwater recharge, derived from a multi-proxy approach, including (1) a hydrological model covering a 30-years dataset, (2) groundwater level measurements and (3) information about springs. The model enables evaluation of the impact of abstraction on the flow regime and the groundwater budget of the resource. Sensitivity analyses of controlling parameters indicate that intense abstraction in the southern part of the Wadi al Arab system can result in critical water-level drops of 10 m at a distance of 16 km from the production wells. Moreover, modelling results suggest that observed head fluctuations are strongly controlled by anthropogenic abstraction rather than variable recharge rates due to climate changes.

  19. Assessment of Effectiveness of Geologic Isolation Systems. Variable thickness transient ground-water flow model. Volume 2. Users' manual

    International Nuclear Information System (INIS)

    Reisenauer, A.E.

    1979-12-01

    A system of computer codes to aid in the preparation and evaluation of ground-water model input, as well as in the computer codes and auxillary programs developed and adapted for use in modeling major ground-water aquifers is described. The ground-water model is interactive, rather than a batch-type model. Interactive models have been demonstrated to be superior to batch in the ground-water field. For example, looking through reams of numerical lists can be avoided with the much superior graphical output forms or summary type numerical output. The system of computer codes permits the flexibility to develop rapidly the model-required data files from engineering data and geologic maps, as well as efficiently manipulating the voluminous data generated. Central to these codes is the Ground-water Model, which given the boundary value problem, produces either the steady-state or transient time plane solutions. A sizeable part of the codes available provide rapid evaluation of the results. Besides contouring the new water potentials, the model allows graphical review of streamlines of flow, travel times, and detailed comparisons of surfaces or points at designated wells. Use of the graphics scopes provide immediate, but temporary displays which can be used for evaluation of input and output and which can be reproduced easily on hard copy devices, such as a line printer, Calcomp plotter and image photographs

  20. Transient pseudohypoaldosteronism

    Directory of Open Access Journals (Sweden)

    Stajić Nataša

    2011-01-01

    Full Text Available Introduction. Infants with urinary tract malformations (UTM presenting with urinary tract infection (UTI are prone to develop transient type 1 pseudohypoaldosteronism (THPA1. Objective. Report on patient series with characteristics of THPA1, UTM and/or UTI and suggestions for the diagnosis and therapy. Methods. Patients underwent blood and urine electrolyte and acid-base analysis, serum aldosterosterone levels and plasma rennin activity measuring; urinalysis, urinoculture and renal ultrasound were done and medical and/or surgical therapy was instituted. Results. Hyponatraemia (120.9±5.8 mmol/L, hyperkalaemia (6.9±0.9 mmol/L, metabolic acidosis (plasma bicarbonate, 11±1.4 mmol/L, and a rise in serum creatinine levels (145±101 μmol/L were associated with inappropriately high urinary sodium (51.3±17.5 mmol/L and low potassium (14.1±5.9 mmol/L excretion. Elevated plasma aldosterone concentrations (170.4±100.5 ng/dL and the very high levels of the plasma aldosterone to potassium ratio (25.2±15.6 together with diminished urinary K/Na values (0.31±0.19 indicated tubular resistance to aldosterone. After institution of appropriate medical and/or surgical therapy, serum electrolytes, creatinine, and acid-base balance were normalized. Imaging studies showed ureteropyelic or ureterovesical junction obstruction in 3 and 2 patients, respectively, posterior urethral valves in 3, and normal UT in 1 patient. According to our knowledge, this is the first report on THPA1 in the Serbian literature. Conclusion. Male infants with hyponatraemia, hyperkalaemia and metabolic acidosis have to have their urine examined and the renal ultrasound has to be done in order to avoid both, the underdiagnosis of THPA1 and the inappropriate medication.

  1. Application of a high-throughput relative chemical stability assay to screen therapeutic protein formulations by assessment of conformational stability and correlation to aggregation propensity.

    Science.gov (United States)

    Rizzo, Joseph M; Shi, Shuai; Li, Yunsong; Semple, Andrew; Esposito, Jessica J; Yu, Shenjiang; Richardson, Daisy; Antochshuk, Valentyn; Shameem, Mohammed

    2015-05-01

    In this study, an automated high-throughput relative chemical stability (RCS) assay was developed in which various therapeutic proteins were assessed to determine stability based on the resistance to denaturation post introduction to a chaotrope titration. Detection mechanisms of both intrinsic fluorescence and near UV circular dichroism (near-UV CD) are demonstrated. Assay robustness was investigated by comparing multiple independent assays and achieving r(2) values >0.95 for curve overlays. The complete reversibility of the assay was demonstrated by intrinsic fluorescence, near-UV CD, and biologic potency. To highlight the method utility, we compared the RCS assay with differential scanning calorimetry and dynamic scanning fluorimetry methodologies. Utilizing C1/2 values obtained from the RCS assay, formulation rank-ordering of 12 different mAb formulations was performed. The prediction of long-term stability on protein aggregation is obtained by demonstrating a good correlation with an r(2) of 0.83 between RCS and empirical aggregation propensity data. RCS promises to be an extremely useful tool to aid in candidate formulation development efforts based on the complete reversibility of the method to allow for multiple assessments without protein loss and the strong correlation between the C1/2 data obtained and accelerated stability under stressed conditions. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  2. Field assessment of the use of borehole pressure transients to measure the permeability of fractured rock masses

    International Nuclear Information System (INIS)

    Forster, C.B.; Gale, J.E.

    1981-06-01

    A field experiment to evaluate the transient pressure pulse technique as a method of determining the in-situ hydraulic conductivity of low permeability fractured rock was made. The experiment attempted to define: the radius of influence of a pressure pulse-test in fractured rock and the correlation between pressure-pulse tests and steady-state flow tests performed in five boreholes drilled in fractured granite. Twenty-five test intervals, 2 to 3 m in length, were isolated in the boreholes, using air-inflated packers. During pressure pulse and steady-state tests, pressures were monitored in both the test and observation cavities. Rock-mass conductivities were calculated from steady-state test results and were found to range from less than 10 - 11 to 10 - 7 cm/sec. However, there was no consistent correlation between the steady-state conductivity and the pressure pulse decay characteristics of individual intervals. These conflicting test results can be attributed to the following factors: differences in volumes of rock affected by the test techniques; effects of equipment configuration and compliance; and complexity of the fracture network. Although the steady-state flow tests indicate that hydraulic connections exist between most of the test cavities, no pressure responses were noted in the observation cavities (located at least 0.3 m from the test cavities) during the pulse tests. This does not mean, however, that the pressure-pulse radius of influence is <0.3 m, because the observation cavities were too large (about 7 liters). The lack of correlation between steady-state conductivities and the corresponding pressure pulse decay times does not permit use of existing single-fracture type curves to analyze pulse tests performed in multiple-fracture intervals. Subsequent work should focus on the detailed interpretation of field results with particular reference to the effects of the fracture system at the test site

  3. Assessing the accuracy and stability of variable selection methods for random forest modeling in ecology.

    Science.gov (United States)

    Fox, Eric W; Hill, Ryan A; Leibowitz, Scott G; Olsen, Anthony R; Thornbrugh, Darren J; Weber, Marc H

    2017-07-01

    Random forest (RF) modeling has emerged as an important statistical learning method in ecology due to its exceptional predictive performance. However, for large and complex ecological data sets, there is limited guidance on variable selection methods for RF modeling. Typically, either a preselected set of predictor variables are used or stepwise procedures are employed which iteratively remove variables according to their importance measures. This paper investigates the application of variable selection methods to RF models for predicting probable biological stream condition. Our motivating data set consists of the good/poor condition of n = 1365 stream survey sites from the 2008/2009 National Rivers and Stream Assessment, and a large set (p = 212) of landscape features from the StreamCat data set as potential predictors. We compare two types of RF models: a full variable set model with all 212 predictors and a reduced variable set model selected using a backward elimination approach. We assess model accuracy using RF's internal out-of-bag estimate, and a cross-validation procedure with validation folds external to the variable selection process. We also assess the stability of the spatial predictions generated by the RF models to changes in the number of predictors and argue that model selection needs to consider both accuracy and stability. The results suggest that RF modeling is robust to the inclusion of many variables of moderate to low importance. We found no substantial improvement in cross-validated accuracy as a result of variable reduction. Moreover, the backward elimination procedure tended to select too few variables and exhibited numerous issues such as upwardly biased out-of-bag accuracy estimates and instabilities in the spatial predictions. We use simulations to further support and generalize results from the analysis of real data. A main purpose of this work is to elucidate issues of model selection bias and instability to ecologists interested in

  4. Analysis of transients aimed at assessing the feasibility of eliminating the HO-2 accident protection and the ''moderate leak'' SOB signal

    International Nuclear Information System (INIS)

    Sommer, J.

    1993-12-01

    Accidents and transient processes were analyzed in order to assess the feasibility of eliminating the 2nd level accident protection (HO-2). All analyses were performed in 3 alternatives, viz. for the normal performance of HO-2, for the HO-2 signals being transferred to the 1st level accident protection (HO-1), and for a complete elimination of HO-2. Transfer of HO-2 signals to HO-1 definitely brings about an improvement of the nuclear power plant operation safety. There is no evidence indicating that the safety would decrease intolerably if HO-2 were eliminated altogether. Elimination of the ''moderate leak'' safety system does not require any thermohydraulic analysis to be performed. 18 refs

  5. Comparison of transient arterial occlusion and muscle exercise provocation for assessment of perfusion reserve in skeletal muscle with real-time contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Krix, Martin; Krakowski-Roosen, Holger; Armarteifio, Erick; Fuerstenberger, Susanne; Delorme, Stefan; Kauczor, Hans-Ulrich; Weber, Marc-Andre

    2011-01-01

    Objective: Contrast-enhanced ultrasound (CEUS) is able to quantify muscle perfusion and changes in perfusion due to muscle exercise in real-time. However, reliable measurement of standardized muscle exercise is difficult to perform in clinical examinations. We compared perfusion reserve assessed by CEUS after transient arterial occlusion and exercise to find the most suitable measurement for clinical application. Methods: Contrast pulse sequencing (7 MHz) during continuous IV infusion of SonoVue (4.8 mL/300 s) was used in 8 healthy volunteers to monitor muscle perfusion of the gastrocnemius muscle during transient (1 min) arterial occlusion produced by a thigh cuff of a venous occlusion plethysmograph. Isometric muscle exercise (50% of individual maximum strength for 20 s) was subsequently performed during the same examination, and several CEUS parameters obtained from ultrasound-signal-intensity-time curves and its calculation errors were compared. Results: The mean maximum local blood volume after occlusion was 13.9 [∼mL] (range, 4.5-28.8 [∼mL]), and similar values were measured after sub-maximum exercise 13.8 [∼mL], (range, 4.6-22.2 [∼mL]. The areas under the curve during reperfusion vs. recovery were also similar (515.2 ± 257.5 compared to 482.2 ± 187.5 [∼mL s]) with a strong correlation (r = 0.65), as were the times to maximum (15.3 s vs. 15.9 s), with a significantly smaller variation for the occlusion method (±2.1 s vs. ±9.0 s, p = 0.03). The mean errors for all calculated CEUS parameters were lower for the occlusion method than for the exercise test. Conclusions: CEUS muscle perfusion measurements can be easily performed after transient arterial occlusion. It delivers data which are comparable to CEUS measurements after muscle exercise but with a higher robustness. This method can be easily applied in clinical examination of patients with e.g. PAOD or diabetic microvessel diseases to assess perfusion reserve.

  6. Channel Planform Dynamics Monitoring and Channel Stability Assessment in Two Sediment-Rich Rivers in Taiwan

    Directory of Open Access Journals (Sweden)

    Cheng-Wei Kuo

    2017-01-01

    Full Text Available Recurrent flood events induced by typhoons are powerful agents to modify channel morphology in Taiwan’s rivers. Frequent channel migrations reflect highly sensitive valley floors and increase the risk to infrastructure and residents along rivers. Therefore, monitoring channel planforms is essential for analyzing channel stability as well as improving river management. This study analyzed annual channel changes along two sediment-rich rivers, the Zhuoshui River and the Gaoping River, from 2008 to 2015 based on satellite images of FORMOSAT-2. Channel areas were digitized from mid-catchment to river mouth (~90 km. Channel stability for reaches was assessed through analyzing the changes of river indices including braid index, active channel width, and channel activity. In general, the valley width plays a key role in braided degree, active channel width, and channel activity. These indices increase as the valley width expands whereas the braid index decreases slightly close to the river mouth due to the change of river types. This downstream pattern in the Zhuoshui River was interrupted by hydraulic construction which resulted in limited changes downstream from the weir, due to the lack of water and sediment supply. A 200-year flood, Typhoon Morakot in 2009, induced significant changes in the two rivers. The highly active landscape in Taiwan results in very sensitive channels compared to other regions. An integrated Sensitivity Index was proposed for identifying unstable reaches, which could be a useful reference for river authorities when making priorities in river regulation strategy. This study shows that satellite image monitoring coupled with river indices analysis could be an effective tool to evaluate spatial and temporal changes in channel stability in highly dynamic river systems.

  7. A plan for the modification and assessment of TRAC-PF1/MOD2 for use in analyzing CANDU 3 transient thermal-hydraulic phenomena

    International Nuclear Information System (INIS)

    Siebe, D.A.; Boyack, B.E.; Giguere, P.T.

    1994-11-01

    This report presents the results of the review and planning done for the United States Nuclear Regulatory Commission to identify the thermal-hydraulic phenomena that could occur in the CANDU 3 reactor design during transient conditions, plan modifications to the TRAC-PF1/MOD2 (TRAC) computer code needed to adequately predict CANDU 3 transient thermal-hydraulic phenomena, and identify an assessment program to verify the ability of TRAC, when modified, to predict these phenomena. This work builds on analyses and recommendations produced by the Idaho National Engineering Laboratory (INEL). To identify the thermal-hydraulic phenomena, a large-break loss-of-coolant accident simulation, performed as part of earlier work by INEL with an Atomic Energy of Canada, Limited (AECL) thermal-hydraulic computer code (CATHENA), was analyzed in detail. Other accident scenarios were examined for additional phenomena. A group of Los Alamos National Laboratory reactor thermal-hydraulics experts ranked the phenomena to produce a preliminary phenomena identification and ranking table (PIRT). The preliminary nature of the PIRT was a result of a lack of direct expertise with the unique processes and phenomena of the CANDU 3. Nonetheless, this PIRT provided an adequate foundation for planning a program of code modifications. We believe that this PIRT captured the most important phenomena and that refinements to the PIRT will mainly produce clarification of the relative importance (ranking) of phenomena. A plan for code modifications was developed based on this PIRT and on information about the modeling methodologies for CANDU-specific phenomena used in AECL codes. AECL thermal-hydraulic test facilities and programs were reviewed and the information used in developing an assessment plan to ensure that TRAC-PF1/MOD2, when modified, will adequately predict CANDU 3 phenomena

  8. Acoustic radiation force impulse-imaging and transient elastography for non-invasive assessment of liver fibrosis and steatosis in NAFLD

    International Nuclear Information System (INIS)

    Friedrich-Rust, Mireen; Romen, Daniela; Vermehren, Johannes; Kriener, Susanne; Sadet, Dilek; Herrmann, Eva; Zeuzem, Stefan; Bojunga, Joerg

    2012-01-01

    Background: Transient elastography (TE) and acoustic radiation force impulse (ARFI)-imaging have shown promising results for the staging of liver fibrosis. Aim: The aim of the present study was to compare ARFI of the left and right liver lobe with TE using the standard and obese probes for the diagnosis of liver fibrosis in NAFL/NASH. In addition, liver steatosis is evaluated using the novel controlled attenuation parameter (CAP). Methods: Sixty-one patients with NAFLD/NASH were included in the study. All patients received TE with both probes, ARFI of both liver lobes and CAP. The results were compared with liver histology. Results: 57 patients were included in the final analysis. The diagnostic accuracy for TE measurements with the M-and XL-probe and for ARFI of the right and left liver lobe was 0.73, 0.84, 0.71 and 0.60 for the diagnosis of severe fibrosis, and 0.93, 0.93, 0.74 and 0.90 for the diagnosis of cirrhosis, respectively. No significant difference of results was observed between TE and ARFI in the subgroup of patients with reliable TE-measurement when taking into account the best results of both methods. However, while a significant correlation could be found for TE with histological liver fibrosis, the correlation of ARFI with liver fibrosis was not statistically significant. A significant correlation was found for CAP with histological steatosis (r = 0.49, p < 0.001). Conclusions: No significant difference in diagnostic accuracy for the non-invasive assessment of liver fibrosis was found for transient elastography and ARFI. Nevertheless TE significantly correlated with liver fibrosis while ARFI did not. CAP enables the non-invasive assessment of steatosis.

  9. Modelling of an ULOF transient in a sodium fast reactor

    International Nuclear Information System (INIS)

    Droin, Jean-Baptiste

    2016-01-01

    Within the framework of the Generation IV Sodium-cooled Fast Reactor (SFR) R and D program of CEA (French Commissariat a l'Energie Atomique et aux Energies Alternatives), safety in case of severe accidents is assessed.Such transients are usually simulated with mechanistic codes (such as SAS-SFR and SIMMER III). as a complement to these codes, which give reference accidental transient calculations, a new physico-statistical approach is currently followed by the CEA; its final objective being to derive the variability of the main results of interest for safety. This approach involves a fast-running description of extended accident sequences coupling physical models for the main phenomena to advanced statistical analysis techniques. It enables to perform a large number of simulations in a reasonable computational time and to describe all the possible bifurcations of the accident transient.In this context, this PhD work presents the physical tool (models and results assessment) dedicated to the initiation and primary phases of an Unprotected Loss Of Flow accident (i.e. until the end of sub-assemblies degradation and before large molten pools formation). The accident phenomenology during these phases is described and illustrated by numerous experimental evidences.It is underlined that the features of the new heterogeneous core concept (called CFV of the French ASTRID prototype) leads to different kinds of ULOF transients than those occurring in the previous past homogeneous cores (SuperPhenix, Phenix...). Indeed, its negative void effect drops the nuclear power when sodium heats-up and possibly boils. This enables three types of ULOF transients characterized by various core final states; the first two types leading to final coolable core states in natural circulation flow (the first one in single phase, the second one in stabilized two-phase flow) whereas the core undergoes a flow excursion followed by sub-assemblies degradation in the last type. In this study, a

  10. Stability assessment of a multi-port power electronic interface for hybrid micro-grid applications

    Science.gov (United States)

    Shamsi, Pourya

    Migration to an industrial society increases the demand for electrical energy. Meanwhile, social causes for preserving the environment and reducing pollutions seek cleaner forms of energy sources. Therefore, there has been a growth in distributed generation from renewable sources in the past decade. Existing regulations and power system coordination does not allow for massive integration of distributed generation throughout the grid. Moreover, the current infrastructures are not designed for interfacing distributed and deregulated generation. In order to remedy this problem, a hybrid micro-grid based on nano-grids is introduced. This system consists of a reliable micro-grid structure that provides a smooth transition from the current distribution networks to smart micro-grid systems. Multi-port power electronic interfaces are introduced to manage the local generation, storage, and consumption. Afterwards, a model for this micro-grid is derived. Using this model, the stability of the system under a variety of source and load induced disturbances is studied. Moreover, pole-zero study of the micro-grid is performed under various loading conditions. An experimental setup of this micro-grid is developed, and the validity of the model in emulating the dynamic behavior of the system is verified. This study provides a theory for a novel hybrid micro-grid as well as models for stability assessment of the proposed micro-grid.

  11. MR tomography in the assessment of functional stability of posterolateral lumbar fusions

    International Nuclear Information System (INIS)

    Lang, P.; Genant, H.K.; Chafetz, N.; Steiger, P.; Stoller, D.; California Univ., San Francisco

    1987-01-01

    MR tomography was used to assess functional lumbar stability in 30 patients with posterolateral fusions. The vertebral bodies of 9 of the 12 patients with unstable lumbar fusions presented with areas of decreased signal intensity on T 1 - and intermediately weighted images, which increased on T 2 -weighting. The vertebrae of 15 of the 18 patients with stable fusions demonstrated zones of increased signal intensity on T 1 - and intermediately weighted images, which were less intense or invisible on T 2 -weighting. Surgical correlation was available in 11 of the 30 patients studied. Hyperemia and inflammation appear to be responsible for the abnormal signal intensities in the patients with stable fusions, whereas an increase in adipose marrow due to decreased biomechanical stress is thought to account for the atypical signal intensities in the vertebral bodies of the patients with stable fusions. MR tomography seems to be a potential method for evaluating functional lumbar fusion stability. MR tomography may be particularly helpful in those patients with multiple back surgeries and possible instability, recurrent disc herniation, or post-operative fibrosis. MR is recommended in the patient, who appears clinically unstable, whose radiographs and CT, however, do not demonstrate fusion failure. (orig.) [de

  12. Impediment in upper airway stabilizing forces assessed by phrenic nerve stimulation in sleep apnea patients

    Directory of Open Access Journals (Sweden)

    Vérin E

    2005-09-01

    Full Text Available Abstract Background The forces developed during inspiration play a key role in determining upper airway stability and the occurrence of nocturnal breathing disorders. Phrenic nerve stimulation applied during wakefulness is a unique tool to assess Upper airway dynamic properties and to measure the overall mechanical effects of the inspiratory process on UA stability. Objectives To compare the flow/pressure responses to inspiratory and expiratory twitches between sleep apnea subjects and normal subjects. Methods Inspiratory and expiratory twitches using magnetic nerve stimulation completed in eleven untreated sleep apnea subjects and ten normal subjects. Results In both groups, higher flow and pressure were reached during inspiratory twitches. The two groups showed no differences in expiratory twitch parameters. During inspiration, the pressure at which flow-limitation occurred was more negative in normals than in apneic subjects, but not reaching significance (p = 0.07. The relationship between pharyngeal pressure and flow adequately fitted with a polynomial regression model providing a measurement of upper airway critical pressure during twitch. This pressure significantly decreased in normals from expiratory to inspiratory twitches (-11.1 ± 1.6 and -15.7 ± 1.0 cm H2O respectively, 95% CI 1.6–7.6, p Conclusion Inspiratory-related upper airway dilating forces are impeded in sleep apnea patients.

  13. CHANGE IN CONDYLAR POSITION AND SKELETAL STABILITY ASSESSMENT FOLLOWING BSSO FOR MANDIBULAR SET BACK

    Directory of Open Access Journals (Sweden)

    Manjunath

    2015-09-01

    Full Text Available Change in condylar position following mandibular bilateral sagittal split osteotomy (BSSO has been implicated as an important factor in the appearance of immediate postoperative relapse during rigid fixation. It has been suggested that the control of the condylar segment following BSSO is the most important aspect in preventing relapse. The study was done to evaluate changes in position of condyle taken with lateral and frontal cephalograms with 20 patients were assessed, 10 male and 10 female patients wer e divided as group 1 and group 2. Patients undergoing sagittal split ramus osteotomy for mandibular set back were selected; radiographs before operation/surgery, immediately after surgery, 3 months and 6 months post - surgery. Differences between groups were measured by PAIRED ‘T’ TEST a nd time dependent changes in cephalometric measurements were examined by FISCHERS TEST. The present study results conclude significant difference occurring in both proximal and distal segment including condyle. Occlusal stabil ity and skeletal stability also maintained post operatively

  14. Impedance Stability Assessment of Active Damping Strategies for LCL Grid-Connected Converters

    DEFF Research Database (Denmark)

    Diaz, Enrique Rodriguez; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2017-01-01

    as a countermeasure. This paper analyses the robustness of the closed-loop dynamics when different active damping strategies are implemented. Due to their readiness and simplicity, the following schemes are considered: 1) filtered capacitor voltage feed-forward and 2) notch filters in cascade with the main current......The use of LCL filters is a well accepted solution to attenuate the harmonics created by the pulsewidth modulation (PWM). However, inherently LCL filters have a resonance region where the unwanted harmonics are amplified, which can compromise instability. Active damping strategies are implemented...... controller. The impedance/admittance stability formulation is used to model the system, which has been proven to be very convenient for the assessment of robustness. The design case study shows that the filtered capacitor voltage feed-forward provides a more robust implementation than the one based...

  15. Isolation and Assessment of Stability of Six Formulations of Entomopathogenic Beauveria bassiana.

    Science.gov (United States)

    Mwamburi, Lizzy A

    2016-01-01

    Beauveria bassiana is the most widely studied and exploited entomopathogen. The development of a suitable formulation for B. bassiana is a critical component in aiding the entomopathogen germinate and infect the host. In addition to being economical to produce, having high residual activity, it is also important that the formulation is easy to handle, stable during storage, and convenient to mix and apply and be consistently effective in controlling the target pest.In this chapter we describe preparation of experimental formulations of conidia of B. bassiana. The formulations are prepared with barley, rice, wheat bran, clay, kaolin, and peat. The protocol for assessing the stability of the formulations of B. bassiana is also described.

  16. STUDY REGARDING THE ASSESSMENT OF THE FINANCIAL STABILITY OF THE ECONOMIC ENTITIES

    Directory of Open Access Journals (Sweden)

    N. Baltes

    2016-11-01

    Full Text Available The research presents both theoretical and practicalthe evolution of the financial stability assessed through the solvency indicators, the real economic growth rate and the GDP deflator in the manufacturing companies from Romania, through the Vector Autoregression Model (VAR. The sample consists in 36 companies belonging to the manufacturing industry in Romania, listed on the Bucharest Stock Exchange, on the first and second category. The study is conducted during the period 2007-2014 and demonstrated the fact that a change in the real economic growth causes a positive change in the GDP deflator. Not lastly, the change of the real economic growth also determines a positive change of the patrimonial solvency, and a change in the GDP deflator produces a reduction of the patrimonial solvency.

  17. Phasor Measurement Unit Test and Applications for Small Signal Stability Assessment and Improvement of Power System

    DEFF Research Database (Denmark)

    Ghiga, Radu

    to be less predictable. Therefore, the methods used for stability and security assessment will most likely use information from the wide-area measurements systems (WAMS). The work presented in this thesis deals on one hand with the development of test methods and validation of phasor measurement units (PMUs......) which are considered to be one of the key technologies in WAMS, and on the other hand with the possibility of using PMU measurements together with large wind power plants (WPPs) to help improve the damping of inter area oscillations. To validate the PMUs, a laboratory test setup is assembled....... The hardware components are capable of generating, with the required accuracy, the test signals injected in the PMUs. The signals are created according to the requirements defined in the current IEEE C37.118.1-2011 standard, to test the steady-state and dynamic compliance of the PMUs. The performance...

  18. Assessment of chromatographic methods for the chemical stability of a new miconazole nitrate cream

    International Nuclear Information System (INIS)

    Garcia Pulpeiro, Oscar; Calzadilla Aguiar, Wendy; Rodriguez Bencomo, Wendy

    2013-01-01

    To assess the chromatographic methods for the chemical stability of a new 2 % miconazol nitrate cream. arious degradation conditions were firstly used in the raw material miconazole nitrate in order to obtain the possible degradation products of this drug and to evaluate them by thin layer chromatography-based method, which was validated to identify the degradation products in the new cream. The performance of the official method based on high resolution liquid chromatography and reported in British Pharmacopoeia 2010 was evaluated, and its selectivity against the possible degradation products were also analyzed. Both chromatographic methods were applied to the analysis of cream samples from the three pilot batches under heat stress for 30 days

  19. Genomic stability and physiological assessments of live offspring sired by a bull clone, Starbuck II.

    Science.gov (United States)

    Ortegon, H; Betts, D H; Lin, L; Coppola, G; Perrault, S D; Blondin, P; King, W A

    2007-01-01

    It appears that overt phenotypic abnormalities observed in some domestic animal clones are not transmitted to their progeny. The current study monitored Holstein heifers sired by a bull clone, Starbuck II, from weaning to puberty. Genomic stability was assessed by telomere length status and chromosomal analysis. Growth parameters, blood profiles, physical exams and reproductive parameters were assessed for 12 months (and compared to age-matched control heifers). Progeny sired by the clone bull did not differ (P>0.05) in weight, length and height compared to controls. However, progeny had lower heart rates (HR) (P=0.009), respiratory rates (RR) (P=0.007) and body temperature (P=0.03). Hematological profiles were within normal ranges and did not differ (P>0.05) between both groups. External and internal genitalia were normal and both groups reached puberty at expected ages. Progeny had two or three ovarian follicular waves per estrous cycle and serum progesterone concentrations were similar (P=0.99) to controls. Telomere lengths of sperm and blood cells from Starbuck II were not different (P>0.05) than those of non-cloned cattle; telomere lengths of progeny were not different (P>0.05) from age-matched controls. In addition, progeny had normal karyotypes in peripheral blood leukocytes compared to controls (89.1% versus 86.3% diploid, respectively). In summary, heifers sired by a bull clone had normal chromosomal stability, growth, physical, hematological and reproductive parameters, compared to normal heifers. Furthermore, they had moderate stress responses to routine handling and restraint.

  20. Assessment of predictive capability of REFLA/TRAC code for large break LOCA transient in PWR using LOFT L2-5 test data

    International Nuclear Information System (INIS)

    Akimoto, Hajime; Ohnuki, Akira; Murao, Yoshio

    1994-03-01

    The REFLA/TRAC code is a best estimate code developed at Japan Atomic Energy Research Institute (JAERI) to provide advanced predictions of thermal hydraulic transient in light water reactors (LWRs). The REFLA/TRAC code uses the TRAC-PF1/MOD1 code as the framework of the code. The REFLA/TRAC code is expected to be used for the calibration of licensing codes, accident analysis, accident simulation of LWRs, and design of advanced LWRs. Several models have been implemented to the TRAC-PF1/MOD1 code at JAERI including reflood model, condensation model, interfacial and wall friction models, etc. These models have been verified using data from various separate effect tests. This report describes an assessment result of the REFLA/TRAC code, which was performed to assess the predictive capability for integral system behavior under large break loss of coolant accident (LBLOCA) using data from the LOFT L2-5 test. The assessment calculation confirmed that the REFLA/TRAC code can predict break mass flow rate, emergency core cooling water bypass and clad temperature excellently in the LOFT L2-5 test. The CPU time of the REFLA/TRAC code was about 1/3 of the TRAC-PF1/MOD1 code. The REFLA/TRAC code can perform stable and fast simulation of thermal hydraulic behavior in PWR LBLOCA with enough accuracy for practical use. (author)

  1. OECD/DOE/CEA VVER-1000 coolant transient (V1000CT) benchmark for assessing coupled neutronics/thermal-hydraulics system codes for VVER-1000 RIA analysis

    International Nuclear Information System (INIS)

    Ivanov, B.; Ivanov, K.; Aniel, S.; Royer, E.; Kolev, N.; Groudev, P.

    2004-01-01

    The present paper describes the two phases of the OECD/DOE/CEA VVER-1000 coolant transient benchmark labeled as V1000CT. This benchmark is based on a data from the Bulgarian Kozloduy NPP Unit 6. The first phase of the benchmark was designed for the purpose of assessing neutron kinetics and thermal-hydraulic modeling for a VVER-1000 reactor, and specifically for their use in analyzing reactivity transients in a VVER-1000 reactor. Most of the results of Phase 1 will be compared against experimental data and the rest of the results will be used for code-to-code comparison. The second phase of the benchmark is planned for evaluation and improvement of the mixing computational models. Code-to-code and code-to-data comparisons will be done based on data of a mixing experiment conducted at Kozloduy-6. Main steam line break will be also analyzed in the second phase of the V1000CT benchmark. The results from it will be used for code-to-code comparison. The benchmark team has been involved in analyzing different aspects and performing sensitivity studies of the different benchmark exercises. The paper presents a comparison of selected results, obtained with two different system thermal-hydraulics codes, with the plant data for the Exercise 1 of Phase 1 of the benchmark as well as some results for Exercises 2 and 3. Overall, this benchmark has been well accepted internationally, with many organizations representing 11 countries participating in the first phase of the benchmark. (authors)

  2. CSNI Integral test facility validation matrix for the assessment of thermal-hydraulic codes for LWR LOCA and transients

    International Nuclear Information System (INIS)

    1996-07-01

    This report deals with an internationally agreed integral test facility (ITF) matrix for the validation of best estimate thermal-hydraulic computer codes. Firstly, the main physical phenomena that occur during the considered accidents are identified, test types are specified, and test facilities suitable for reproducing these aspects are selected. Secondly, a life of selected experiments carried out in these facilities has been set down. The criteria to achieve the objectives are outlined. The construction of such a matrix is an attempt to collect together in a systematic way the best sets of openly available test data for code validation, assessment and improvement, including quantitative assessment of uncertainties in the modelling of phenomena by the codes. In addition to this objective, it is an attempt to record information which has been generated around the world over the last 20 years so that it is more accessible to present and future workers in that field than would otherwise be the case

  3. Experimental and Thermalhydraulic Code Assessment of the Transient Behavior of the Passive Condenser System in an Advanced Boiling Water Reactor

    Energy Technology Data Exchange (ETDEWEB)

    S.T. Revankar; W. Zhou; Gavin Henderson

    2008-07-08

    The main goal of the project was to study analytically and experimentally the condensation heat transfer for the passive condenser system such as GE Economic Simplified Boiling Water Reactor (ESBWR). The effect of noncondensable gas in condenser tube and the reduction of secondary pool water level to the condensation heat transfer coefficient was the main focus in this research. The objectives of this research were to : 1) obtain experimental data on the local and tube averaged condensation heat transfer rates for the PCCS with non-condensable and with change in the secondary pool water, 2) assess the RELAP5 and TRACE computer code against the experimental data, and 3) develop mathematical model and ehat transfer correlation for the condensation phenomena for system code application. The project involves experimentation, theoretical model development and verification, and thermal- hydraulic codes assessment.

  4. Experimental and Thermalhydraulic Code Assessment of the Transient Behavior of the Passive Condenser System in an Advanced Boiling Water Reactor

    International Nuclear Information System (INIS)

    S.T. Revankar; W. Zhou; Gavin Henderson

    2008-01-01

    The main goal of the project was to study analytically and experimentally the condensation heat transfer for the passive condenser system such as GE Economic Simplified Boiling Water Reactor (ESBWR). The effect of noncondensable gas in condenser tube and the reduction of secondary pool water level to the condensation heat transfer coefficient was the main focus in this research. The objectives of this research were to: (1) obtain experimental data on the local and tube averaged condensation heat transfer rates for the PCCS with non-condensable and with change in the secondary pool water, (2) assess the RELAP5 and TRACE computer code against the experimental data, and (3) develop mathematical model and heat transfer correlation for the condensation phenomena for system code application. The project involves experimentation, theoretical model development and verification, and thermal-hydraulic codes assessment

  5. Current interruption transients calculation

    CERN Document Server

    Peelo, David F

    2014-01-01

    Provides an original, detailed and practical description of current interruption transients, origins, and the circuits involved, and how they can be calculated Current Interruption Transients Calculationis a comprehensive resource for the understanding, calculation and analysis of the transient recovery voltages (TRVs) and related re-ignition or re-striking transients associated with fault current interruption and the switching of inductive and capacitive load currents in circuits. This book provides an original, detailed and practical description of current interruption transients, origins,

  6. A multidisciplinary methodological approach for slope stability assessment of an area prone to shallow landslides

    Science.gov (United States)

    Bordoni, Massimiliano; Meisina, Claudia; Valentino, Roberto; Bittelli, Marco; Battista Bischetti, Gian; Vercesi, Alberto; Chersich, Silvia; Giuseppina Persichillo, Maria

    2016-04-01

    Rainfall-induced shallow landslides are widespread slope instabilities phenomena in several hilly and mountainous contexts all over the world. Due to their high density of diffusion also in small areas, they can provoke important damages to terrains, infrastructures, buildings, and, sometimes, loss of human lives. Shallow landslides affect superficial soils of limited thickness (generally lower than 2 m), located above weathered or not bedrock levels. Their triggering mechanism is strictly linked to the hydrological response of the soils to rainfall events. Thus, it becomes fundamental a comprehensive analysis of the soil properties which can influence the susceptibility of a slope to shallow landslides. In this study, a multidisciplinary approach was followed for the characterization of the soils and the individuation of the triggering conditions in an area particularly prone to shallow failures, for slope stability assessment. This area corresponded to the hilly sector of North-Eastern Oltrepò Pavese (Lombardy Region, Northern Italy), where the density of shallow landslides is really high, reaching more than 36 landslides per km2. The soils of the study area were analyzed through a multidisciplinary characterization, which took into account for the main geotechnical, mechanical and mineralogical parameters and also for the main pedological features of the materials. This approach allowed for identifying the main features and the horizons which could influence the soil behavior in relation to the conditions that are preparatory to shallow landslides development. In a test-site slope, representative of the main geomorphological, geological and landslides distribution characteristics typical of the study area, a continuous in time monitoring of meteorological (rainfall amount, air temperature, air humidity, atmospheric pressure, net solar radiation, wind speed and direction) and hydrological (soil water content, pore water pressure) parameters was implemented. In

  7. Breath holding endurance: stability over time and relationship with self-assessed persistence

    Directory of Open Access Journals (Sweden)

    Daisy G.Y. Thompson-Lake

    2017-09-01

    Full Text Available Breath holding (BH endurance has been suggested as a measure of the distress tolerance that could predict the outcome of attempts to implement behavior changes, such as stopping smoking or illicit substance use. It is not known however, to what degree BH endurance is a variable trait that may vary depending on situational context, or a stable state characteristic. We measured BH in two groups of participants at baseline and 22 and 89 days (N = 62 and N = 41 post-baseline and in a third group at multiple times points across a 5-week period (N = 44. Participants also filled out a questionnaire created to assess their perceived persistence compared to peers. Correlations were found between baseline and final BH measures (r’s > 0.67, p’s < 0.0001 at all time points. When groups were combined, regardless of time point, Spearman’s rank correlation showed a strong positive correlation (rs = 0.66, p < 0.0001. Self-assessed persistence was not related to BH endurance. This study provides evidence of the stability of BH across time when tested under the same conditions in young adults. Further research is needed to clarify whether BH is linked to behavioral outcomes.

  8. Using education and support strategies to improve the way nurses assess regular and transient pain - A quality improvement study of three hospitals.

    Science.gov (United States)

    Peterson, Anna; Carlfjord, Siw; Schaller, Anne; Gerdle, Björn; Larsson, Britt

    2017-07-01

    of pain assessments. Further research is needed that examines the large discrepancy between patient-reported pain management and documentation in the medical recording system of transient pain. Copyright © 2017 Scandinavian Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  9. Silver nanoparticles in complex biological media: assessment of colloidal stability and protein corona formation

    Energy Technology Data Exchange (ETDEWEB)

    Argentiere, Simona, E-mail: simona.argentiere@fondazionefilarete.com; Cella, Claudia, E-mail: claudia.cella@unimi.it [Fondazione Filarete (Italy); Cesaria, Maura, E-mail: maura.cesaria@le.infn.it [Università del Salento, Dipartimento di Matematica e Fisica “Ennio De Giorgi” (Italy); Milani, Paolo, E-mail: paolo.milani@mi.infn.it; Lenardi, Cristina, E-mail: cristina.lenardi@mi.infn.it [Università degli Studi di Milano, CIMAINA and Dipartimento di Fisica (Italy)

    2016-08-15

    Engineered silver nanoparticles (AgNPs) are among the most used nanomaterials in consumer products, therefore concerns are raised about their potential for adverse effects in humans and environment. Although an increasing number of studies in vitro and in vivo are being reported on the toxicity of AgNPs, most of them suffer from incomplete characterization of AgNPs in the tested biological media. As a consequence, the comparison of toxicological data is troublesome and the toxicity evaluation still remains an open critical issue. The development of a reliable protocol to evaluate interactions of AgNPs with surrounding proteins as well as to assess their colloidal stability is therefore required. In this regard, it is of importance not only to use multiple, easy-to-access and simple techniques but also to understand limitations of each characterization methods. In this work, the morphological and structural behaviour of AgNPs has been studied in two relevant biological media, namely 10 % FBS and MP. Three different techniques (Dynamic Light Scattering, Transmission Electron Microscopy, UV–Vis spectroscopy) were tested for their suitability in detecting AgNPs of three different sizes (10, 40 and 100 nm) coated with either citrate or polyvinylpyrrolidone. Results showed that UV–Vis spectroscopy is the most versatile and informative technique to gain information about interaction between AgNPs and surrounding proteins and to determine their colloidal stability in the tested biological media. These findings are expected to provide useful insights in characterizing AgNPs before performing any further in vitro/in vivo experiment.

  10. Assessment of Rock Slope Stability in Limestone Quarries in the Tournai's Region (Belgium) Using Structural Data

    Science.gov (United States)

    Tshibangu, Jean-Pierre; Deloge, K. Pierre-Alexandre; Deschamps, Benoît; Coudyzer, Christophe

    The Tournais region is characterised by famous outcrops of carboniferous limestone which is mined out for cement and raw material production. The four main quarries found in the Region, i.e. Gaurain-Ramecroix, Milieu, Antoing and Lemay; are owned by the three main cement producers in Belgium: Italcimenti, Holcim and CBR. The global production of limestone is about 20 millions tons per year, giving big pits with depths up to 150 m. With the growth of the pits, the quarries are approaching each other leading to the problem of managing the reserves contained in the separating walls and their mechanical stability. The limestone deposit is composed of different seams having varying thickness, chemical com- position and even mechanical properties. The deposit has an overall horizontal dip and is intersected by two main sets of discontinuities with a spacing of about 10 m or less. It is also crossed by a set of east to west faults but the quarries are implanted in the in between areas, so to not be crossed by these faults. The layers and specially the shallow ones are characterised by a typical karstic weathering giving open or filled cavities. This paper presents the global work quarried out in order to study the stability of the Lemays quarry. First a description of the orientation and spacing of discontinuities is presented, and an attempt made to correlate to the development of weathering. Mechanical laboratory tests have been performed and a qualification of the rock mass assessed. A coupled approach is then presented using a mining planning analysis and mechanical simulation (i.e. Finite Element method).

  11. Controlled assessment of the efficacy of occlusal stabilization splints on sleep bruxism.

    Science.gov (United States)

    van der Zaag, Jacques; Lobbezoo, Frank; Wicks, Darrel J; Visscher, Corine M; Hamburger, Hans L; Naeije, Machiel

    2005-01-01

    To assess the efficacy of occlusal stabilization splints in the management of sleep bruxism (SB) in a double-blind, parallel, controlled, randomized clinical trial. Twenty-one participants were randomly assigned to an occlusal splint group (n = 11; mean age = 34.2 +/- 13.1 years) or a palatal splint (ie, an acrylic palatal coverage) group (n = 10; mean age = 34.9 +/- 11.2 years). Two polysomnographic recordings that included bilateral masseter electromyographic activity were made: one prior to treatment, the other after a treatment period of 4 weeks. The number of bruxism episodes per hour of sleep (Epi/h), the number of bursts per hour (Bur/h), and the bruxism time index (ie, the percentage of total sleep time spent bruxing) were established as outcome variables at a 10% maximum voluntary contraction threshold level. A general linear model was used to test both the effects between splint groups and within the treatment phase as well as their interaction for each outcome variable. Neither occlusal stabilization splints nor palatal splints had an influence on the SB outcome variables or on the sleep variables measured on a group level. In individual cases, variable outcomes were found: Some patients had an increase (33% to 48% of the cases), while others showed no change (33% to 48%) or a decrease (19% to 29%) in SB outcome variables. The absence of significant group effects of splints in the management of SB indicates that caution is required when splints are indicated, apart from their role in the protection against dental wear. The application of splints should therefore be considered at the individual patient level.

  12. Performance of 2-D shear wave elastography in liver fibrosis assessment compared with serologic tests and transient elastography in clinical routine.

    Science.gov (United States)

    Bota, Simona; Paternostro, Rafael; Etschmaier, Alexandra; Schwarzer, Remy; Salzl, Petra; Mandorfer, Mattias; Kienbacher, Christian; Ferlitsch, Monika; Reiberger, Thomas; Trauner, Michael; Peck-Radosavljevic, Markus; Ferlitsch, Arnulf

    2015-09-01

    Liver stiffness values assessed with 2-D shear wave elastography (SWE), transient elastography (TE) and simple serologic tests were compared with respect to non-invasive assessment in a cohort of 127 consecutive patients with chronic liver diseases. The rate of reliable liver stiffness measurements was significantly higher with 2-D SWE than with TE: 99.2% versus 74.8%, p < 0.0001 (different reliability criteria used, according to current recommendations). In univariate analysis, liver stiffness measured with 2-D SWE correlated best with fibrosis stage estimated with TE (r = 0.699, p < 0.0001), followed by Forns score (r = 0.534, p < 0.0001) and King's score (r = 0.512, p < 0.0001). However, in multivariate analysis, only 2-D SWE-measured values remained correlated with fibrosis stage (p < 0.0001). The optimal 2-D SWE cutoff values for predicting significant fibrosis were 8.03 kPa for fibrosis stage ≥2 (area under the receiver operating characteristic curve = 0.832) and 13.1 kPa for fibrosis stage 4 (area under the receiver operating characteristic curve = 0.915), respectively. In conclusion, 2-D SWE can be used to obtain reliable liver stiffness measurements in almost all patients and performs very well in predicting the presence of liver cirrhosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Stability and Transient Effects in Ultraviolet Filaments

    National Research Council Canada - National Science Library

    Niday, Thomas

    2004-01-01

    .... Much of the work in this field has been done with infrared pulses; however, it has been proposed that ultraviolet pulses have the advantage that longer pulse lengths can be used, thereby delivering more energy...

  14. Intention stability assessed using residual change scores moderates the intention-behaviour association: a prospective cohort study.

    Science.gov (United States)

    Rowan, Alicia A; McDermott, Máirtín S; Allen, Mark S

    2017-12-01

    Intention stability is considered to be one of the key pre-requisites for a strong association between intention and behaviour. It has been claimed, however, that studies examining the moderating impact of intention stability may be invalid, as they have relied on statistically inferior methods. Residual change scores have been suggested as a more appropriate method of measuring change (or lack thereof) in constructs. The aim of the current study, therefore, is to test whether intention stability, calculated using residual change scores, moderates the intention-physical activity behaviour association. A total of 163 participants (124 women, 39 men) completed questionnaires online at three time points separated by 14 day intervals. The moderating impact of intention stability was assessed using multiple linear regression followed up using simple slope analyses to identify the direction of any effect. The interaction of intention and intention stability was found to significantly improve the overall model fit. Intentions had a stronger positive association with behaviour when intentions were more stable than when they were more unstable. However, sensitivity analyses revealed that the association was not robust and reduced to non-significant with the removal of potential multivariate outliers. Future research should use residual change scores as the preferred method of assessing intention stability.

  15. Synchronizing noisy nonidentical oscillators by transient uncoupling

    Energy Technology Data Exchange (ETDEWEB)

    Tandon, Aditya, E-mail: adityat@iitk.ac.in; Mannattil, Manu, E-mail: mmanu@iitk.ac.in [Department of Physics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh 208016 (India); Schröder, Malte, E-mail: malte@nld.ds.mpg.de [Network Dynamics, Max Planck Institute for Dynamics and Self-Organization (MPIDS), 37077 Göttingen (Germany); Timme, Marc, E-mail: timme@nld.ds.mpg.de [Network Dynamics, Max Planck Institute for Dynamics and Self-Organization (MPIDS), 37077 Göttingen (Germany); Department of Physics, Technical University of Darmstadt, 64289 Darmstadt (Germany); Chakraborty, Sagar, E-mail: sagarc@iitk.ac.in [Department of Physics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh 208016 (India); Mechanics and Applied Mathematics Group, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh 208016 (India)

    2016-09-15

    Synchronization is the process of achieving identical dynamics among coupled identical units. If the units are different from each other, their dynamics cannot become identical; yet, after transients, there may emerge a functional relationship between them—a phenomenon termed “generalized synchronization.” Here, we show that the concept of transient uncoupling, recently introduced for synchronizing identical units, also supports generalized synchronization among nonidentical chaotic units. Generalized synchronization can be achieved by transient uncoupling even when it is impossible by regular coupling. We furthermore demonstrate that transient uncoupling stabilizes synchronization in the presence of common noise. Transient uncoupling works best if the units stay uncoupled whenever the driven orbit visits regions that are locally diverging in its phase space. Thus, to select a favorable uncoupling region, we propose an intuitive method that measures the local divergence at the phase points of the driven unit's trajectory by linearizing the flow and subsequently suppresses the divergence by uncoupling.

  16. Probabilistic fracture mechanics applied for DHC assessment in the cool-down transients for CANDU pressure tubes

    Energy Technology Data Exchange (ETDEWEB)

    Radu, Vasile, E-mail: vasile.radu@nuclear.ro [Institute for Nuclear Research Pitesti, 1st Campului Street, 115400 Mioveni, Arges, P.O. Box 78, Mioveni (Romania); Roth, Maria [Institute for Nuclear Research Pitesti, 1st Campului Street, 115400 Mioveni, Arges, P.O. Box 78, Mioveni (Romania)

    2012-12-15

    For CANDU pressure tubes made from Zr-2.5%Nb alloy, the mechanism called delayed hydride cracking (DHC) is widely recognized as main mechanism responsible for crack initiation and propagation in the pipe wall. Generation of some blunt flaws at the inner pressure tube surface during refueling by fuel bundle bearing pad or by debris fretting, combined with hydrogen/deuterium up-take (20-40 ppm) from normal corrosion process with coolant, may lead to crack initiation and growth. The process is governed by hydrogen hysteresis of terminal solid solubility limits in Zirconium and the diffusion of hydrogen atoms in the stress gradient near to a stress spot (flaw). Creep and irradiation growth under normal operating conditions promote the specific mechanisms for Zirconium alloys, which result in circumferential expansion, accompanied by wall thinning and length increasing. These complicate damage mechanisms in the case of CANDU pressure tubes that are also are affected by irradiation environment in the reactor core. The structural integrity assessment of CANDU fuel channels is based on the technical requirements and methodology stated in the Canadian Standard N285.8. Usually it works with fracture mechanics principles in a deterministic manner. However, there are inherent uncertainties from the in-service inspection, which are associated with those from material properties determination; therefore a necessary conservatism in deterministic evaluation should be used. Probabilistic approach, based on fracture mechanics principle and appropriate limit state functions defined as fracture criteria, appears as a promising complementary way to evaluate structural integrity of CANDU pressure tubes. To perform this, one has to account for the uncertainties that are associated with the main parameters for pressure tube assessment, such as: flaws distribution and sizing, initial hydrogen concentration, fracture toughness, DHC rate and dimensional changes induced by long term

  17. Preliminary assessment of potential underground stability (wedge and spalling) at Forsmark, Simpevarp and Laxemar sites

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Derek [Univ. of Alberta, Edmonton (Canada). Geotechnical Engineering

    2005-12-15

    In SKB's Underground Design Premises the objective in the early design phase is to estimate if there is sufficient space for the repository at a site. One of the conditions that could limit the space available is stability of the underground openings, i.e., deposition tunnels and deposition boreholes. The purpose of this report is to provide a preliminary assessment of the potential for wedge instability and spalling that may be encountered at the Forsmark, Simpevarp and Laxemar sites based on information from the site investigations program up to July 30, 2004. The rock mass spalling strength was defined using the in-situ results from SKB's Aespoe Pillar Stability Experiment and AECL's Mine-by Experiment. These experiments suggest that the rock mass spalling strength for crystalline rocks can be estimated as 0.57 of the mean laboratory uniaxial compressive strength. A probability-based methodology utilizing this in-situ rock mass spalling strength has been developed for assessing the risk for spalling in a repository at the Forsmark, Simpevarp and Laxemar sites. The in-situ stresses and the uniaxial compressive strength data from these sites were used as the bases for the analyses. Preliminary findings from all sites suggest that, generally, the risk for spalling increases as the depth of the repository increases, simply because the stress magnitudes increase with depth. The depth at which the risk for spalling is significant, depends on the individual sites which are discussed below. The greatest uncertainty in the spalling analyses for Forsmark is related to the uncertainty in the horizontal stress magnitudes and associated stress gradients with depth. The confidence in these analyses can only be increased by increasing the confidence in the stress and geology model for the site. From the analyses completed it appears that spalling in the deposition tunnels can be controlled by orienting the tunnels approximately parallel to the maximum horizontal

  18. Transient phenomena in electrical power systems

    CERN Document Server

    Venikov, V A; Higinbotham, W

    1964-01-01

    Electronics and Instrumentation, Volume 24: Transient Phenomena in Electrical Power Systems presents the methods for calculating the stability and the transient behavior of systems with forced excitation control. This book provides information pertinent to the analysis of transient phenomena in electro-mechanical systems.Organized into five chapters, this volume begins with an overview of the principal requirements in an excitation system. This text then explains the electromagnetic and electro-mechanical phenomena, taking into account the mutual action between the components of the system. Ot

  19. Complication assessment and prevention strategies using midfoot fusion bolt for medial column stabilization in Charcot's osteoarthropathy

    DEFF Research Database (Denmark)

    Mehlhorn, Alexander T; Walther, Markus; Iblher, Niklas

    2016-01-01

    and stabilization using midfoot fusion bolt and lateral lag screws. Age, gender, presence of preoperative osteomyelitis or ulcer, number of complications and operative revisions, Hba1c value, consolidation of arthrodesis, presence of a load-bearing foot and period to bolt dislocation was assessed. The mean follow......-up was 21.4±14.6 (mean±SDM) months, 64% of patients suffered from diabetes with a preoperative Hba1c of 8.5±2.4. The mean number of revisions per foot was 3.6±4.1. Bolt dislocation was seen in 57% of the patients following 11.3±8.5 months; in 75% of these patients bony healing occurred before dislocation....... There was a significant association between preoperative increased Hba1c value, presence of preoperative ulcer and wound infection. Healing of arthrodesis was demonstrated in 57% and a permanent weight-bearing foot without recurrent ulcer was achieved in 79%. The early and late postoperative complications could...

  20. Ultra-high resolution four dimensional geodetic imaging of engineered structures for stability assessment

    Science.gov (United States)

    Bawden, Gerald W.; Bond, Sandra; Podoski, J. H.; Kreylos, O.; Kellogg, L. H.

    2012-01-01

    We used ground-based Tripod LiDAR (T-LiDAR) to assess the stability of two engineered structures: a bridge spanning the San Andreas fault following the M6.0 Parkfield earthquake in Central California and a newly built coastal breakwater located at the Kaumālapa`u Harbor Lana'i, Hawaii. In the 10 weeks following the earthquake, we found that the surface under the bridge shifted 7.1 cm with an additional 2.6 cm of motion in the subsequent 13 weeks, which deflected the bridge's northern I-beam support 4.3 cm and 2.1 respectively; the bridge integrity remained intact. T-LiDAR imagery was collected after the completion of armored breakwater with 817 35-ton interlocking concrete armor units, Core-Locs®, in the summers of 2007, 2008 and 2010. We found a wide range of motion of individual Core-Locs, from a few centimeters to >110 cm along the ocean side of the breakwater, with lesser movement along the harbor side.

  1. Methods for assessing the stability of slopes during earthquakes-A retrospective

    Science.gov (United States)

    Jibson, R.W.

    2011-01-01

    During the twentieth century, several methods to assess the stability of slopes during earthquakes were developed. Pseudostatic analysis was the earliest method; it involved simply adding a permanent body force representing the earthquake shaking to a static limit-equilibrium analysis. Stress-deformation analysis, a later development, involved much more complex modeling of slopes using a mesh in which the internal stresses and strains within elements are computed based on the applied external loads, including gravity and seismic loads. Stress-deformation analysis provided the most realistic model of slope behavior, but it is very complex and requires a high density of high-quality soil-property data as well as an accurate model of soil behavior. In 1965, Newmark developed a method that effectively bridges the gap between these two types of analysis. His sliding-block model is easy to apply and provides a useful index of co-seismic slope performance. Subsequent modifications to sliding-block analysis have made it applicable to a wider range of landslide types. Sliding-block analysis provides perhaps the greatest utility of all the types of analysis. It is far easier to apply than stress-deformation analysis, and it yields much more useful information than does pseudostatic analysis. ?? 2010.

  2. Assessment of Stability and Energy Dissipation Performances of an Antifer Layer Protected Caisson

    Directory of Open Access Journals (Sweden)

    M. Sedat Kabdaşlı

    2015-08-01

    Full Text Available The present study intends to assess the stability and energy dissipation performances of a breakwater configuration (APC protected by an antifer layer. For comparison, an ordinary caisson (OC, which was 5% wider and 10% heavier, was also investigated. Physical models were implemented and tested under regular and irregular waves; and resulting linear and angular displacements were directly measured via a photogrammetric method. Additionally, wave forces and resulting horizontal displacements were estimated both from recorded pressure data and from individual incident waves by modified Goda method. To calculate the horizontal displacement, the estimated wave force time series were directly double-integrated, whilst the theoretical method proposed by Shimosako et al. (1994 were used on the individual force values. Although OC was tested under shorter durations and had a more favorable superstructure in terms of resisting forces, the results indicated that APC was significantly more stable. Energy dissipation performance of the tested configurations were quantified in terms of spectral averaged and phase resolved reflection coefficients, whereas antifer damage ratio was measured on a block-count basis. Results indicated that the APC configuration had an enhanced performance of dissipating the wave energy; moreover, the dissipated energy directly links to antifer damage ratio.

  3. Assessing the stability of soil organic matter by fractionation and 13C isotope techniques

    Science.gov (United States)

    Larionova, A. A.; Zolotareva, B. N.; Kvitkina, A. K.; Evdokimov, I. V.; Bykhovets, S. S.; Stulin, A. F.; Kuzyakov, Ya. V.; Kudeyarov, V. N.

    2015-02-01

    Carbon pools of different stabilities have been separated from the soil organic matter of agrochernozem and agrogray soil samples. The work has been based on the studies of the natural abundance of the carbon isotope composition by C3-C4 transition using the biokinetic, size-density, and chemical fractionation (6 M HCl hydrolysis) methods. The most stable pools with the minimum content of new carbon have been identified by particle-size and chemical fractionation. The content of carbon in the fine fractions has been found to be close to that in the nonhydrolyzable residue. This pool makes up 65 and 48% of Corg in the agrochernozems and agrogray soils, respectively. The combination of the biokinetic approach with particle-size fractionation or 6 M HCl hydrolysis has allowed assessing the size of the medium-stable organic carbon pool with a turnover time of several years to several decades. The organic matter pool with this turnover rate is usually identified from the variation in the 13C abundance by C3-C4 transition. In the agrochernozems and agrogray soils, the medium-stable carbon pool makes up 35 and 46% of Corg, respectively. The isotope indication may be replaced by a nonisotope method to significantly expand the study of the inert and mediumstable organic matter pools in the geographical aspect, but this requires a comparative analysis of particle-size and chemical fractionation data for all Russian soils.

  4. Comparative water quality assessment between a young and a stabilized hydroelectric reservoir in Aliakmon River, Greece.

    Science.gov (United States)

    Samiotis, Georgios; Trikoilidou, Eleni; Tsikritzis, Lazaros; Amanatidou, Elisavet

    2018-03-20

    In this work, a comparative study on the water quality characteristics of two in-line water reservoirs (artificial lakes) in Aliakmon River (Western Macedonia, Greece) is performed. Polyfytos Reservoir and Ilarion Reservoir were created in 1975 and 2012 respectively, in order to serve the homonymous hydroelectric stations. In young artificial lakes, severe deterioration of water quality may occur; thus, the monitoring and assessment of their water quality characteristics and their statistical interpretation are of great importance. In order to evaluate any temporal or spatial variations and to characterize water quality of these two in-line water reservoirs, water quality data from measurements conducted from 2012 to 2015 were statistically processed and interpreted by using a modified National Sanitation Foundation water quality index (WQI). The water physicochemical characteristics of the two reservoirs were found to be generally within the legislation limits, with relatively small temporal and spatial variations. Although Polyfytos Reservoir showed no significant deviations of its water quality, Ilarion Reservoir exhibited deviations in total Kjeldahl nitrogen, nitrite nitrogen, total suspended solids, and turbidity due to the inundated vegetation decomposition. The conducted measurements and the use of the modified NSFWQI revealed that during the inundation period of Ilarion Reservoir, its water quality was "moderate" and that the deviations were softened through time, leading to "good" water quality during its maturation period. Three years since the creation of Ilarion Reservoir, water quality does not match that of Aliakmon River (feeding water) or that of the stabilized reservoir (Polyfytos Reservoir), whose quality is characterized as "high." The use of a WQI, such as the proposed modified NSFWQI, for evaluating water quality of each sampling site and of an entire water system proved to be a rapid and relatively accurate assessment tool.

  5. VSC Input-Admittance Modeling and Analysis Above the Nyquist Frequency for Passivity-Based Stability Assessment

    DEFF Research Database (Denmark)

    Harnefors, Lennart; Finger, Raphael; Wang, Xiongfei

    2017-01-01

    The interconnection stability of a gridconnected voltage-source converter (VSC) can be assessed via the dissipative properties of its input admittance. In this paper, the modeling of the current control loop is revisited with the aim to improve the accuracy of the input-admittance model above...

  6. Assessment of the 3He pressure inside the CABRI transient rods - Development of a surrogate model based on measurements and complementary CFD calculations

    Science.gov (United States)

    Clamens, Olivier; Lecerf, Johann; Hudelot, Jean-Pascal; Duc, Bertrand; Cadiou, Thierry; Blaise, Patrick; Biard, Bruno

    2018-01-01

    CABRI is an experimental pulse reactor, funded by the French Nuclear Safety and Radioprotection Institute (IRSN) and operated by CEA at the Cadarache research center. It is designed to study fuel behavior under RIA conditions. In order to produce the power transients, reactivity is injected by depressurization of a neutron absorber (3He) situated in transient rods inside the reactor core. The shapes of power transients depend on the total amount of reactivity injected and on the injection speed. The injected reactivity can be calculated by conversion of the 3He gas density into units of reactivity. So, it is of upmost importance to properly master gas density evolution in transient rods during a power transient. The 3He depressurization was studied by CFD calculations and completed with measurements using pressure transducers. The CFD calculations show that the density evolution is slower than the pressure drop. Surrogate models were built based on CFD calculations and validated against preliminary tests in the CABRI transient system. Studies also show that it is harder to predict the depressurization during the power transients because of neutron/3He capture reactions that induce a gas heating. This phenomenon can be studied by a multiphysics approach based on reaction rate calculation thanks to Monte Carlo code and study the resulting heating effect with the validated CFD simulation.

  7. Assessment of the 3He pressure inside the CABRI transient rods - Development of a surrogate model based on measurements and complementary CFD calculations

    Directory of Open Access Journals (Sweden)

    Clamens Olivier

    2018-01-01

    Full Text Available CABRI is an experimental pulse reactor, funded by the French Nuclear Safety and Radioprotection Institute (IRSN and operated by CEA at the Cadarache research center. It is designed to study fuel behavior under RIA conditions. In order to produce the power transients, reactivity is injected by depressurization of a neutron absorber (3He situated in transient rods inside the reactor core. The shapes of power transients depend on the total amount of reactivity injected and on the injection speed. The injected reactivity can be calculated by conversion of the 3He gas density into units of reactivity. So, it is of upmost importance to properly master gas density evolution in transient rods during a power transient. The 3He depressurization was studied by CFD calculations and completed with measurements using pressure transducers. The CFD calculations show that the density evolution is slower than the pressure drop. Surrogate models were built based on CFD calculations and validated against preliminary tests in the CABRI transient system. Studies also show that it is harder to predict the depressurization during the power transients because of neutron/3He capture reactions that induce a gas heating. This phenomenon can be studied by a multiphysics approach based on reaction rate calculation thanks to Monte Carlo code and study the resulting heating effect with the validated CFD simulation.

  8. Clinical course in infants diagnosed with transient tachypnea of newborn: A clinical trial assessing the role of conservative versus conventional management.

    Science.gov (United States)

    Dehdashtian, M; Aletayeb, M; Malakian, A; Aramesh, M R; Malvandi, H

    2018-02-01

    Transient tachypnea of the newborn (TTN) is a respiratory disorder secondary to inadequate or delayed clearance of lung fluids. Early symptoms of the disease are indistinguishable from neonatal respiratory distress syndrome, pneumonia, and persistent pulmonary hypertension. Therefore, these newborns, in addition to receiving conservative management, receive antibiotics until blood cultures provide definite results. In this study, we assessed the clinical course of neonates diagnosed with TTN who received conventional versus conservative management. One hundred and thirty neonates diagnosed as having TTN were randomly enrolled in two study groups. While patients belonging to one group received conservative management, those from the other group were treated with conventional medical therapy. Mean duration of hospitalization was 7 ± 0.2 in the conventional and 5 ± 1.5 in the conservative group. Duration of antibiotic therapy was 6.7 ± 2.47 days in the conventional group. Newborns diagnosed with TTN without prenatal risk factors and a negative C reactive protein test do not need to be administered antibiotics and hospitalized until confirmatory blood culture results are obtained. Copyright © 2017. Published by Elsevier Taiwan LLC.

  9. Hybrid algorithm for rotor angle security assessment in power systems

    Directory of Open Access Journals (Sweden)

    D. Prasad Wadduwage

    2015-08-01

    Full Text Available Transient rotor angle stability assessment and oscillatory rotor angle stability assessment subsequent to a contingency are integral components of dynamic security assessment (DSA in power systems. This study proposes a hybrid algorithm to determine whether the post-fault power system is secure due to both transient rotor angle stability and oscillatory rotor angle stability subsequent to a set of known contingencies. The hybrid algorithm first uses a new security measure developed based on the concept of Lyapunov exponents (LEs to determine the transient security of the post-fault power system. Later, the transient secure power swing curves are analysed using an improved Prony algorithm which extracts the dominant oscillatory modes and estimates their damping ratios. The damping ratio is a security measure about the oscillatory security of the post-fault power system subsequent to the contingency. The suitability of the proposed hybrid algorithm for DSA in power systems is illustrated using different contingencies of a 16-generator 68-bus test system and a 50-generator 470-bus test system. The accuracy of the stability conclusions and the acceptable computational burden indicate that the proposed hybrid algorithm is suitable for real-time security assessment with respect to both transient rotor angle stability and oscillatory rotor angle stability under multiple contingencies of the power system.

  10. Transient drainage summary report

    International Nuclear Information System (INIS)

    1996-09-01

    This report summarizes the history of transient drainage issues on the Uranium Mill Tailings Remedial Action (UMTRA) Project. It defines and describes the UMTRA Project disposal cell transient drainage process and chronicles UMTRA Project treatment of the transient drainage phenomenon. Section 4.0 includes a conceptual cross section of each UMTRA Project disposal site and summarizes design and construction information, the ground water protection strategy, and the potential for transient drainage

  11. assessment of yield stability in sorghum abstract résumé

    African Journals Online (AJOL)

    Administrator

    environment followed by combined analysis of variance using IRRISTAT for Windows Version. 4.0. (IRRI, 1999). Because the genotype-by-environment interaction was significant, five out of the nine stability models, which were grouped into four groups and latter, divided in to three types of stability by Lin et al. (1986), were ...

  12. Assessment of read and write stability for 6T SRAM cell based on charge plasma DLTFET

    Science.gov (United States)

    Anju; Yadav, Shivendra; Sharma, Dheeraj

    2018-03-01

    To overcome the process variations due to random dopant fluctuations (RDFs) and complex annealing techniques a charge plasma based doping less TFET (CP-DLTFET) device has been proposed for designing of 6T SRAM cell. The proposed device also benefited by subthreshold slope, low leakage current, and low power supply. In this paper, to avoid the dependency of stability parameters of SRAM cell to supply voltage (Vdd), here N-curve metrics has been analyzed to determine read and write stability. Because N-curve provides stability analysis in terms of voltage and current as well as it gives combine stability analysis with the facility of an inline tester. Further, analyzing the N-curve metrics for different Vdd, cell ratio, and pull-up ratio assist in designing the configuration of transistors for the better read and write stability. Power metrics of N-curve gives the knowledge about read and write stability instead of using four metrics (SINM, SVNM, WTV, and WTI) of N-curve. Finally, in the 6T CP-DLTFET SRAM cell, read and write stability is tested by the interface trap charges (ITCs). The performance parameter of the 6T CP-DLTFET SRAM cell provides considerable read and write stability with less fabrication complexity.

  13. Assessment of zerovalent iron for stabilization of chromium, copper, and arsenic in soil

    International Nuclear Information System (INIS)

    Kumpiene, Jurate; Ore, Solvita; Renella, Giancarlo; Mench, Michel; Lagerkvist, Anders; Maurice, Christian

    2006-01-01

    Stabilization of soil contaminated with trace elements is a remediation practice that does not reduce the total content of contaminants, but lowers the amounts of mobile and bioavailable fractions. This study evaluated the efficiency of Fe to reduce the mobility and bioavailability of Cr, Cu, As and Zn in a chromated copper arsenate (CCA)-contaminated soil using chemical, biochemical and biotoxicity tests. Contaminated soil was stabilized with 1% iron grit. This treatment decreased As and Cr concentrations in leachates (by 98% and 45%, respectively), in soil pore water (by 99% and 94%, respectively) and in plant shoots (by 84% and 95%, respectively). The stabilization technique also restored most of analyzed soil enzyme activities and reduced microbial toxicity, as evaluated by the BioTox TM test. After stabilization, exchangeable and bioaccessible fractions of Cu remained high, causing some residual toxicity in the treated soil. - Zerovalent iron effectively reduces mobility and bioavailability of As and Cr, but does not adequately stabilize Cu

  14. PSH Transient Simulation Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-21

    PSH Transient Simulation Modeling presentation from the WPTO FY14 - FY16 Peer Review. Transient effects are an important consideration when designing a PSH system, yet numerical techniques for hydraulic transient analysis still need improvements for adjustable-speed (AS) reversible pump-turbine applications.

  15. Assessment of Liver Fibrosis by Transient Elastography Should Be Done After Hemodialysis in End Stage Renal Disease Patients with Liver Disease.

    Science.gov (United States)

    Taneja, Sunil; Borkakoty, Amritangsu; Rathi, Sahaj; Kumar, Vivek; Duseja, Ajay; Dhiman, Radha K; Gupta, Krishan L; Chawla, Yogesh

    2017-11-01

    The patients with end stage renal disease (ESRD) are at greater risk of acquiring chronic hepatitis B or C and subsequently development of liver disease. The aim of the study was to assess liver fibrosis by transient elastography (TE) and look for factors associated with change in liver stiffness measurement (LSM) with one session of hemodialysis (HD). Consecutive ESRD patients on maintenance hemodialysis (MHD) with suspected liver disease were enrolled. They underwent LSM by TE before and after one session of HD. Bioelectric impedance analysis was done to evaluate the volume status at the time of TE. Sixty-eight patients with mean age of 40 ± 14 years were included. There was a significant reduction in LSM after HD (18.5 [95% CI 14.8-23.1] vs. 11.2 [95% CI 8.8-13.7] kPa, p  or  2.5 L (8.6 [95% CI 5.7-11.5] vs. 5.1 [95% CI 2.9-7.5], p = 0.05). In 18 patients who underwent liver biopsy, LSM after HD performed better at detecting significant fibrosis, with area under receiver operating characteristics curve 0.71 [95% CI 0.46-0.97], versus 0.64 [95% CI 0.38-0.90], respectively. An LSM value of 12.2 kPa after HD was 71% sensitive and 74% specific for detection of significant fibrosis (≥ F2), while values less than 9 kPa ruled out significant fibrosis with a sensitivity and specificity of 37 and 100%, respectively. LSM by TE decreases significantly after HD in patients with ESRD on long-term MHD. Hence, TE should be done after HD for accurate assessment of liver fibrosis.

  16. Specificity of HPLC to assess the chemical stability based on partenine from Parthenium hysterophorus L. powdered dry foliage (escoba amarga)

    International Nuclear Information System (INIS)

    Saucedo Hernandez, Yanelis; Mohamad Safa, Bassam; Gonzalez Bedia, Mirtha Mayra

    2010-01-01

    It is required a specific analysis technique allowing the follow-up to stability study intrinsic of Parthenium hysterophorus L. (escoba amarga) powdered dry foliage to achieve in a pharmaceutical way a antiparasitic usefulness with the quality, safety and effectiveness demanded requirements. High performance liquid chromatography was applied to P. hysterophorus degraded samples under degradation conditions in an oxidative, basic and acid medium. The analysis technique specificity was assessed to detect the interest component without interferences of its degradation products and its possible usefulness in studies on solid stability in the plant powder

  17. Influences of geological parameters to probabilistic assessment of slope stability of embankment

    Science.gov (United States)

    Nguyen, Qui T.; Le, Tuan D.; Konečný, Petr

    2018-04-01

    This article considers influences of geological parameters to slope stability of the embankment in probabilistic analysis using SLOPE/W computational system. Stability of a simple slope is evaluated with and without pore–water pressure on the basis of variation of soil properties. Normal distributions of unit weight, cohesion and internal friction angle are assumed. Monte Carlo simulation technique is employed to perform analysis of critical slip surface. Sensitivity analysis is performed to observe the variation of the geological parameters and their effects on safety factors of the slope stability.

  18. Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

    Science.gov (United States)

    Choi, Taeyoung; Xiong, Xiaxiong; Chander, G.; Angal, Amit

    2009-01-01

    ) was included in the path of this continuous orbit, which served as a verification point between the shortterm and the long-term trending results from previous studies. This work focuses on monitoring the short-term on-orbit stability of MODIS and the ETM+ RSB. It also provides an assessment of the absolute calibration differences between the two sensors over their wide dynamic ranges.

  19. Small disturbance voltage stability assessment of power systems by modal analysis and dynamic simulation

    International Nuclear Information System (INIS)

    Amjady, Nima; Ansari, Mohammad Reza

    2008-01-01

    The introduction of liberalized electricity markets in many countries has resulted in more highly stressed power systems. On the other hand, operating points of a power system are acceptable in the feasible region, which is surrounded by the borders of different stabilities. Power system instability is critical for all participants of the electricity market. Determination of different stability margins can result in the optimum utilization of power system with minimum risk. This paper focuses on the small disturbance voltage stability, which is an important subset of the power system global stability. This kind of voltage stability is usually evaluated by static analysis tools such as continuation power flow, while it essentially has dynamic nature. Besides, a combination of linear and nonlinear analysis tools is required to correctly analyze it. In this paper, a hybrid evaluation method composed of static, dynamic, linear, and nonlinear analysis tools is proposed for this purpose. Effect of load scenario, generation pattern, branch and generator contingency on the small disturbance voltage stability are evaluated by the hybrid method. The test results are given for New England and IEEE68 bus test systems. (author)

  20. Transient survivability of LMR oxide fuel pins

    International Nuclear Information System (INIS)

    Weber, E.T.; Pitner, A.L.; Bard, F.E.; Culley, G.E.; Hunter, C.W.

    1986-01-01

    Fuel pin integrity during transient events must be assessed for both the core design and safety analysis phases of a reactor project. A significant increase in the experience related to limits of integrity for oxide fuel pins in transient overpower events has been realized from testing of fuel pins irradiated in FFTF and PFR. Fourteen FFTF irradiated fuel pins were tested in TREAT, representing a range of burnups, overpower ramp rates and maximum overpower conditions. Results of these tests along with similar testing in the PFR/TREAT program, provide a demonstration of significant safety margins for oxide fuel pins. Useful information applied in analytical extrapolation of fuel pin test data have been developed from laboratory transient tests on irradiated fuel cladding (FCTT) and on unirradiated fuel pellet deformation. These refinements in oxide fuel transient performance are being applied in assessment of transient capabilities of long lifetime fuel designs using ferritic cladding

  1. Abnormal liver stiffness assessed using transient elastography (Fibroscan® in HIV-infected patients without HBV/HCV coinfection receiving combined antiretroviral treatment.

    Directory of Open Access Journals (Sweden)

    Sang Hoon Han

    Full Text Available BACKGROUND AND AIMS: Liver stiffness measurement (LSM using transient elastography (Fibroscan® can identify individuals with potential underlying liver disease. We evaluated the prevalence of abnormal LSM values as assessed using LSM and its predictors in HIV-infected asymptomatic patients receiving combined antiretroviral treatment (cART without HBV/HCV coinfection. METHODS: We prospectively recruited 93 patients who had consistently been undergoing cART for more than 12 months at Severance Hospital in Seoul, Republic of Korea, from June to December 2010. LSM values >5.3 kPa were defined as abnormal. RESULTS: Thirty-nine (41.9% had abnormal LSM values. On multivariate correlation analysis, the cumulative duration of boosted and unboosted protease inhibitors (PIs were the independent factors which showed a negative and positive correlation to LSM values, respectively (β = -0.234, P = 0.023 and β = 0.430, P<0.001. In multivariate logistic regression analysis, the cumulative exposure duration of boosted-PIs and γ-glutamyltranspeptidase levels were selected as the independent predictors which showed a negative and positive correlation with abnormal LSM values, respectively (odds ratio [OR], 0.941; 95% confidence interval [CI], 0.889-0.997; P = 0.039 and OR, 1.032; 95% CI, 1.004-1.060; P = 0.023. CONCLUSION: The high percentage of HIV-infected asymptomatic patients receiving cART without HBV/HCV coinfection had abnormal LSM values. The cumulative exposure duration of boosted-PIs and γ-GT level were independent predictors which showed a negative and positive correlation with abnormal LSM values, respectively.

  2. Elastogram quality assessment score in vibration-controlled transient elastography: Diagnostic performance compared to digital morphometric analysis of liver biopsy in chronic hepatitis C.

    Science.gov (United States)

    Mendes, L C; Ferreira, P A; Miotto, N; Zanaga, L; Gonçales, E S L; Pedro, M N; Lazarini, M S; Júnior, F L G; Stucchi, R S B; Vigani, A G

    2018-04-01

    Vibration-controlled transient elastography (VCTE) is widely used for noninvasive fibrosis staging in chronic hepatitis C. However, internal validation is based solely on variability and success rate and lacks reproducible quality indicators. We analysed the graphic representation of shear wave propagation in comparison with morphometric results of liver biopsy, eliminating observer variability bias. Individual elastograms were classified according to two morphologic criteria: extension of wave propagation (length of the graphic representation) and shear wave dispersal (level of parallelism displayed in the elastogram). Then, a score based on these criteria stratified the elastogram in classes I through III (highest to lowest technical quality). Liver stiffness results of each measurement were compared with collagen contents in liver biopsy by morphometric analysis. A total of 3243 elastograms were studied (316 patients). Digital morphometry in liver biopsy showed significant fibrosis in 66% of samples and advanced fibrosis in 31%. Elastogram quality analysis resulted in 1438 class I measurements (44%), 1070 class II (34%) and 735 class III. Area under the receiver operating curve (AUROC) for severe fibrosis according to class (I, II and III) was 0.941, 0.887 and 0.766, respectively. For advanced fibrosis, AUROCs were 0.977, 0.883 and 0.781, respectively. Spearman's correlation testing for all classes and levels of fibrosis demonstrated significant independent association (r 2  = -.95, P digital morphometric imaging analysis. We concluded that VCTE performance is significantly influenced by quality assessment of individual measurements. Considering these criteria in clinical practice may improve accuracy. © 2017 John Wiley & Sons Ltd.

  3. Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density bone.

    Science.gov (United States)

    Kim, Yung-Soo; Lim, Young-Jun

    2011-10-01

    The aim of this biomechanical study was to assess the influence of self-tapping blades in terms of primary implant stability between implants with self-tapping blades and implants without self-tapping blades using five different analytic methods, especially in medium-density bone. Two different types of dental implants (4 × 10 mm) were tested: self-tapping and non-self-tapping. The fixture design including thread profiles was exactly the same between the two groups; the only difference was the presence of cutting blades on one half of the apical portion of the implant body. Solid rigid polyurethane blocks with corresponding densities were selected to simulate medium-density bone. Five mechanical assessments (insertion torque, resonance frequency analysis [RFA], reverse torque, pull-out and push in test) were performed for primary stability. Implants without self-tapping blades showed significantly higher values (P0.05). The outcomes of the present study indicate that the implant body design without self-tapping blades has a good primary stability compared with that with self-tapping blades in medium-density bone. Considering the RFA, a distinct layer of cortical bone on marginal bone will yield implant stability quotient values similar to those in medium-bone density when implants have the same diameter. © 2011 John Wiley & Sons A/S.

  4. Wearable sensor use for assessing standing balance and walking stability in people with Parkinson's disease: a systematic review.

    Science.gov (United States)

    Hubble, Ryan P; Naughton, Geraldine A; Silburn, Peter A; Cole, Michael H

    2015-01-01

    Postural instability and gait disability threaten the independence and well-being of people with Parkinson's disease and increase the risk of falls and fall-related injuries. Prospective research has shown that commonly-used clinical assessments of balance and walking lack the sensitivity to accurately and consistently identify those people with Parkinson's disease who are at a higher risk of falling. Wearable sensors provide a portable and affordable alternative for researchers and clinicians who are seeking to objectively assess movements and falls risk in the clinical setting. However, no consensus currently exists on the optimal placements for sensors and the best outcome measures to use for assessing standing balance and walking stability in Parkinson's disease patients. Hence, this systematic review aimed to examine the available literature to establish the best sensor types, locations and outcomes to assess standing balance and walking stability in this population. Papers listed in three electronic databases were searched by title and abstract to identify articles measuring standing balance or walking stability with any kind of wearable sensor among adults diagnosed with PD. To be eligible for inclusion, papers were required to be full-text articles published in English between January 1994 and December 2014 that assessed measures of standing balance or walking stability with wearable sensors in people with PD. Articles were excluded if they; i) did not use any form of wearable sensor to measure variables associated with standing balance or walking stability; ii) did not include a control group or control condition; iii) were an abstract and/or included in the proceedings of a conference; or iv) were a review article or case study. The targeted search of the three electronic databases identified 340 articles that were potentially eligible for inclusion, but following title, abstract and full-text review only 26 articles were deemed to meet the inclusion

  5. Wearable Sensor Use for Assessing Standing Balance and Walking Stability in People with Parkinson’s Disease: A Systematic Review

    Science.gov (United States)

    Hubble, Ryan P.; Naughton, Geraldine A.; Silburn, Peter A.; Cole, Michael H.

    2015-01-01

    Background Postural instability and gait disability threaten the independence and well-being of people with Parkinson’s disease and increase the risk of falls and fall-related injuries. Prospective research has shown that commonly-used clinical assessments of balance and walking lack the sensitivity to accurately and consistently identify those people with Parkinson’s disease who are at a higher risk of falling. Wearable sensors provide a portable and affordable alternative for researchers and clinicians who are seeking to objectively assess movements and falls risk in the clinical setting. However, no consensus currently exists on the optimal placements for sensors and the best outcome measures to use for assessing standing balance and walking stability in Parkinson’s disease patients. Hence, this systematic review aimed to examine the available literature to establish the best sensor types, locations and outcomes to assess standing balance and walking stability in this population. Methods Papers listed in three electronic databases were searched by title and abstract to identify articles measuring standing balance or walking stability with any kind of wearable sensor among adults diagnosed with PD. To be eligible for inclusion, papers were required to be full-text articles published in English between January 1994 and December 2014 that assessed measures of standing balance or walking stability with wearable sensors in people with PD. Articles were excluded if they; i) did not use any form of wearable sensor to measure variables associated with standing balance or walking stability; ii) did not include a control group or control condition; iii) were an abstract and/or included in the proceedings of a conference; or iv) were a review article or case study. The targeted search of the three electronic databases identified 340 articles that were potentially eligible for inclusion, but following title, abstract and full-text review only 26 articles were deemed

  6. Wearable sensor use for assessing standing balance and walking stability in people with Parkinson's disease: a systematic review.

    Directory of Open Access Journals (Sweden)

    Ryan P Hubble

    Full Text Available Postural instability and gait disability threaten the independence and well-being of people with Parkinson's disease and increase the risk of falls and fall-related injuries. Prospective research has shown that commonly-used clinical assessments of balance and walking lack the sensitivity to accurately and consistently identify those people with Parkinson's disease who are at a higher risk of falling. Wearable sensors provide a portable and affordable alternative for researchers and clinicians who are seeking to objectively assess movements and falls risk in the clinical setting. However, no consensus currently exists on the optimal placements for sensors and the best outcome measures to use for assessing standing balance and walking stability in Parkinson's disease patients. Hence, this systematic review aimed to examine the available literature to establish the best sensor types, locations and outcomes to assess standing balance and walking stability in this population.Papers listed in three electronic databases were searched by title and abstract to identify articles measuring standing balance or walking stability with any kind of wearable sensor among adults diagnosed with PD. To be eligible for inclusion, papers were required to be full-text articles published in English between January 1994 and December 2014 that assessed measures of standing balance or walking stability with wearable sensors in people with PD. Articles were excluded if they; i did not use any form of wearable sensor to measure variables associated with standing balance or walking stability; ii did not include a control group or control condition; iii were an abstract and/or included in the proceedings of a conference; or iv were a review article or case study. The targeted search of the three electronic databases identified 340 articles that were potentially eligible for inclusion, but following title, abstract and full-text review only 26 articles were deemed to meet the

  7. Temperature shock, injury and transient sensitivity to nisin in Gram negatives.

    Science.gov (United States)

    Boziaris, I S; Adams, M R

    2001-10-01

    The effect of thermal stresses on survival, injury and nisin sensitivity was investigated in Salmonella Enteritidis PT4, PT7 and Pseudomonas aeruginosa. Heating at 55 degrees C, rapid chilling to 0.5 degrees C or freezing at -20 degrees C produced transient sensitivity to nisin. Cells were only sensitive if nisin was present during stress. Resistance recovered rapidly afterwards, though some cells displayed residual injury. Injury was assessed by SDS sensitivity, hydrophobicity changes, lipopolysaccharide release and NPN uptake. LPS release and hydrophobicity were not always associated with transient nisin sensitivity. Uptake of NPN correlated better but persisted longer after treatment. Thermal shocks produce transient injury to the outer membrane, allowing nisin access. After treatment, the permeability barrier is rapidly restored by a process apparently involving reorganization rather than biosynthetic repair. Inclusion of nisin during food treatments that impose sub-lethal stress on Gram negatives could increase process lethality, enhancing microbiological safety and stability.

  8. Feedback stabilization initiative

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    Much progress has been made in attaining high confinement regimes in magnetic confinement devices. These operating modes tend to be transient, however, due to the onset of MHD instabilities, and their stabilization is critical for improved performance at steady state. This report describes the Feedback Stabilization Initiative (FSI), a broad-based, multi-institutional effort to develop and implement methods for raising the achievable plasma betas through active MHD feedback stabilization. A key element in this proposed effort is the Feedback Stabilization Experiment (FSX), a medium-sized, national facility that would be specifically dedicated to demonstrating beta improvement in reactor relevant plasmas by using a variety of MHD feedback stabilization schemes.

  9. Feedback stabilization initiative

    International Nuclear Information System (INIS)

    1997-06-01

    Much progress has been made in attaining high confinement regimes in magnetic confinement devices. These operating modes tend to be transient, however, due to the onset of MHD instabilities, and their stabilization is critical for improved performance at steady state. This report describes the Feedback Stabilization Initiative (FSI), a broad-based, multi-institutional effort to develop and implement methods for raising the achievable plasma betas through active MHD feedback stabilization. A key element in this proposed effort is the Feedback Stabilization Experiment (FSX), a medium-sized, national facility that would be specifically dedicated to demonstrating beta improvement in reactor relevant plasmas by using a variety of MHD feedback stabilization schemes

  10. Assessment of rock mechanical properties and seismic slope stability in variably weathered layered basalts

    Science.gov (United States)

    Greenwood, William; Clark, Marin; Zekkos, Dimitrios; Von Voigtlander, Jennifer; Bateman, Julie; Lowe, Katherine; Hirose, Mitsuhito; Anderson, Suzanne; Anderson, Robert; Lynch, Jerome

    2016-04-01

    A field and laboratory experimental study was conducted to assess the influence of weathering on the mechanical properties of basalts in the region of the Kohala volcano on the island of Hawaii. Through the systematic characterization of the weathering profiles developed in different precipitation regimes, we aim to explain the regional pattern of stability of slopes in layered basalts that were observed during the 2006 Mw 6.7 Kiholo Bay earthquake. While deeper weathering profiles on the wet side of the island might be expected to promote more and larger landslides, the distribution of landslides during the Kiholo Bay earthquake did not follow this anticipated trend. Landslide frequency (defined as number of landslides divided by total area) was similar on the steepest slopes (> 50-60) for both the dry and the wet side of the study area suggesting relatively strong ground materials irrespective of weathering. The study location is ideally suited to investigate the role of precipitation, and more broadly of climate, on the mechanical properties of the local rock units because the presence of the Kohala volcano produces a significant precipitation gradient on what are essentially identical basaltic flows. Mean annual precipitation (MAP) varies by more than an order of magnitude, from 200 mm/year on the western side of the volcano to 4000 mm/year in the eastern side. We will present results of measured shear wave velocities using a seismic surface wave methodology. These results were paired with laboratory testing on selected basalt specimens that document the sample-scale shear wave velocity and unconfined compressive strength of the basaltic rocks. Shear wave velocity and unconfined strength of the rocks are correlated and are both significantly lower in weathered rocks near the ground surface than at depth. This weathering-related reduction in shear wave velocity extends to greater depths in areas of high precipitation compared to areas of lower precipitation

  11. Long Term Behaviour of 14C and Stability Assessments of Graphite Under Repository Conditions

    International Nuclear Information System (INIS)

    Jones, Abbie N.; McDermott, Lorraine; Worth, Robert; Hagos, Bereket; Black, Greg; Marsden, Barry J

    2016-01-01

    The key objectives of the University of Manchester’s nuclear graphite research within the CRP are to provide analysis on the long term behaviour and stability assessments of irradiated graphite waste. The research will concentrate on isotopic 14 C mobility under repository environments. This also requires an understanding the long-term behaviour of the final waste form under repository conditions. Procedures to evaluate the long term leaching properties of radionuclides from irradiated graphite waste has been developed by combining ANSI 16.1 (USA) and NEN 7345 (Netherlands) standardised diffusion leaching techniques. The ANSI 16.1 standard has been followed to acquire the leachates and to determine the leach rate and diffusion coefficient. The NEN 7345 standard technique has been used to determine the diffusion mechanism of radionuclides. The investigation employs simulated Drigg groundwater as a leachant using semi-dynamic technique for the production of leachate specimens. Analysis of 3 H and 14 C activity release from Magnox graphite was measured using liquid scintillating counting. Preliminary results show that there is an initial high release of activity and decreases when the leaching period increases. This may be due to the depletion of contaminants that were initially bound by the internal pore networks and the free surface. During the leaching test approximately 275.33 ± 18.20 Bq of 3 H and 106.26 ± 7.01 Bq of 14 C was released into the leachant within 91 days. The work reported herein contributed several key findings to the international work on graphite leaching to offer guidance leading toward obtaining leaching data in the future: (a) the effective diffusion coefficient for 14 C from graphite waste has been determined. The diffusion process for 14 C has two stages resulting two different values of diffusion coefficient, i.e., for the fast and slow components; (b) the controlling leaching mechanism for 3 H radionuclide from graphite is shown to be

  12. Assessment of implant stability during various stages of healing placed immediately following extraction in an overdenture situation

    OpenAIRE

    Ashwin Thomas Koshy; T Aby Mathew; Nicholas Mathew; Angel Mary Joseph

    2017-01-01

    To assess the implant stability during different stages of healing in an immediate loaded implant soon after extraction. A 73-year-old female came with a chief complaint of bad smell and irritation in her lower front gum region. On examination, she was found to be completely edentulous in the maxillary arch and partially edentulous in the mandibular arch with only the canines present bilaterally. The posterior mandibular ridge was severely resorbed and hence could not be treated with a conven...

  13. Taxonomic Structure and Stability of the Bacterial Community in Belgian Sourdough Ecosystems as Assessed by Culture and Population Fingerprinting▿ †

    OpenAIRE

    Scheirlinck, Ilse; Van der Meulen, Roel; Van Schoor, Ann; Vancanneyt, Marc; De Vuyst, Luc; Vandamme, Peter; Huys, Geert

    2008-01-01

    A total of 39 traditional sourdoughs were sampled at 11 bakeries located throughout Belgium which were visited twice with a 1-year interval. The taxonomic structure and stability of the bacterial communities occurring in these traditional sourdoughs were assessed using both culture-dependent and culture-independent methods. A total of 1,194 potential lactic acid bacterium (LAB) isolates were tentatively grouped and identified by repetitive element sequence-based PCR, followed by sequence-base...

  14. The Amalgamation of SVR and ANFIS Models with Synchronized Phasor Measurements for On-Line Voltage Stability Assessment

    Directory of Open Access Journals (Sweden)

    Mohammed Amroune

    2017-10-01

    Full Text Available This paper presents the application of support vector regression (SVR and adaptive neuro-fuzzy inference system (ANFIS models that are amalgamated with synchronized phasor measurements for on-line voltage stability assessment. As the performance of SVR model extremely depends on the good selection of its parameters, the recently developed ant lion optimizer (ALO is adapted to seek for the SVR’s optimal parameters. In particular, the input vector of ALO-SVR and ANFIS soft computing models is provided in the form of voltage magnitudes provided by the phasor measurement units (PMUs. In order to investigate the effectiveness of ALO-SVR and ANFIS models towards performing the on-line voltage stability assessment, in-depth analyses on the results have been carried out on the IEEE 30-bus and IEEE 118-bus test systems considering different topologies and operating conditions. Two statistical performance criteria of root mean square error (RMSE and correlation coefficient (R were considered as metrics to further assess both of the modeling performances in contrast with the power flow equations. The results have demonstrated that the ALO-SVR model is able to predict the voltage stability margin with greater accuracy compared to the ANFIS model.

  15. Assessment of additional impacts to environment during Ukryttya object stabilization works

    International Nuclear Information System (INIS)

    Klyuchnikov, A.A.; Shcherbin, V.N.; Rud'ko, V.M.; Batij, V.G.; Sizov, A.A.; Khavrus', V.G.

    2004-01-01

    Estimates of impact levels onto environment were made when implementing stabilization works of unstable building structures of Ukryttya object. The impact were evaluated to air water medium, as well to ground cover, social and technogenic environments. It was demonstrated, that impact levels to above environmental components under normal conditions of work implementation are negligible, and radioactive substance amount, which will penetrate into the environment, will make parts of percents to existing contamination of exclusion zone area. Estimates are also made of accident impacts onto environment, whose origination is probable during the stabilization works of Ukryttya object

  16. Stabilizing greenhouse gas emissions: Assessing the intergenerational costs and benefits of the Kyoto Protocol

    International Nuclear Information System (INIS)

    Kavuncu, Y. Okan; Knabb, Shawn D.

    2005-01-01

    The costs and benefits current and future generations incur as the result of climate change or an environmental control policy are often confounded with other objectives, such as, generational discounting or optimal policy design. This paper uses a consumption equivalent measure to simulate the loss or gain of consumption independent of these confounding objectives. The findings suggest that the costs associated with an emissions stabilization program are relatively large for current generations and continue to increase over the next 100 years. The first generation to actually benefit from the stabilization program is born early during the 24th century

  17. Stability model and risk assessment for the Montescaglioso Landslide (Southern Italy)

    Science.gov (United States)

    Amanti, Marco; Chiessi, Vittorio; Guarino, Paolo Maria; Spizzichino, Daniele; Troccoli, Alessandro; Vizzini, Giorgio

    2015-04-01

    In this paper, we present the final results of a landslide risk assessment evaluation implemented for the recent Montescaglioso landslide emergency occurred on 3rd December 2013 when a large and rapid slope failure, triggered by prolonged and intense rainfall, affected a big portion of the SW slope of the village. The slope failure damaged a main road, private homes and commercial buildings. The Montescaglioso village (Basilicata Region, Italy) is located on the top of a conglomerate hill overlying a gentle slope constituted by Plio-Pleistocene clays. The area has been affected since ancient time by different landslide typologies and mechanism, as determined by a direct geomorphological survey and from mapping and available technical literature. Phenomena such as rock-falls and rock lateral spreading in the upper part of the hill, and rotational/translational slides and earth flows can be recognized in the area. Landslides are mainly promoted by the geological and structural setting of the area as well as by very low mechanical characteristics of sediments outcropping in the area. After the emergency phase, a detailed program of field survey and laboratory campaign has been implemented during the last year. A detailed topographical analysis has been developed by using the LIDAR survey in order to define morphometric conditions and geometry modifications of the slope affected by the landslide. Based on the studies carried out in the area, the research has been aimed to assessing the stability conditions (residual landslide risk) of the SW slope of the hill trough an extended geological, geomorphological and geotechnical campaign linked with numerical study of present instability mechanism. The geological and geotechnical model of the slope has been defined trough the analysis of the past and recent logs obtained from several boreholes and also through the results of many mechanical test performed on samples taken in the area. The numerical study has been carried out

  18. TRANSIENT ELECTRONICS CATEGORIZATION

    Science.gov (United States)

    2017-08-24

    AFRL-RY-WP-TR-2017-0169 TRANSIENT ELECTRONICS CATEGORIZATION Dr. Burhan Bayraktaroglu Devices for Sensing Branch Aerospace Components & Subsystems...SUBTITLE TRANSIENT ELECTRONICS CATEGORIZATION 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER N/A 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S) Dr. Burhan...88ABW-2017-3747, Clearance Date 31 July 2017. Paper contains color. 14. ABSTRACT Transient electronics is an emerging technology area that lacks proper

  19. Assessing phase stability and element distribution in Co-base superalloys at elevated temperatures by in situ TEM heating experiments

    Energy Technology Data Exchange (ETDEWEB)

    Eggeler, Yolita; Mueller, Julian; Spiecker, Erdmann [Lehrstuhl fuer Mikro- und Nanostrukturforschung and Center for Nanoanalysis and Electron Microscopy (CENEM), Department Werkstoffwissenschaften, Universitaet Erlangen-Nuernberg, Erlangen (Germany)

    2016-07-01

    Co-based alloys, of a composition of Co-12Al-9W, form a stable two phase γ/γ{sup '} microstructure at 900 C. γ{sup '} cubes, consisting of the L12 crystal structure are coherently embedded in a solid solution fcc (A1) γ matrix. To ensure precipitate hardening at temperatures, which are relevant to practical applications, 700-1100 C, as experienced in gas turbine applications, the stability of the γ/γ{sup '} phases is of fundamental importance. In this analysis in situ TEM studies with chip-based heating systems (by DENS solution) are applied on new Co-based superalloys. After in situ heating at apr. 900 C and controlled quenching with different quenching rates the elemental distribution at the γ/γ{sup '} interface is measured using ChemiSTEM EDX. Exploiting the driving force for interface movement resulting from temperature-dependent volume fraction of γ and γ{sup '} insight into the diffusion of individual alloying elements and the relationship between local chemistry and ordering can be gained from transient phenomena. The experimental results will be compared with theoretical calculations. This work has been carried out within the framework of the SFB-TR 103 ''Single Crystal Superalloys''.

  20. Assessment of stability of trace elements in two natural matrix environmental standard reference materials. NIST-SRM 1547 Peach leaves and NIST-SRM 1566a Oyster Tissue

    International Nuclear Information System (INIS)

    Mackey, E.A.; Spatz, R.O.

    2009-01-01

    The NIST program for environmental Standard Reference Materials (SRM) includes materials covering a range of matrices, mass fraction values and analytes. For many SRMs, mass fraction data are accumulated, incidentally, over time, as these are used routinely for quality assurance purposes. Although these are not formal stability studies, data generated may be useful in assessing stability. To evaluate the potential for assessing material stability from incidental use of SRMs, results of neutron activation analysis performed from 1992 through 2008 were compiled for SRM 1547 Peach Leaves and SRM 1566a Oyster Tissue. Results indicate that incidental use of SRMs yields useful information on SRM stability. (author)

  1. Is there a role for oligosaccharides in seed longevity? An assessment of intracellular glass stability

    NARCIS (Netherlands)

    Buitink, J.; Hemminga, M.A.; Hoekstra, F.A.

    2000-01-01

    We examined whether oligosaccharides extend seed longevity by increasing the intracellular glass stability. For that purpose, we used a spin probe technique to measure the molecular mobility and glass transition temperature of the cytoplasm of impatiens (Impatiens walleriana) and bell pepper

  2. A Project Assessment of Stabilizing System of WT Generation using Rechargeable Battery

    Science.gov (United States)

    Kojima, Yasuhiro; Takano, Tomihiro; Tanikawa, Ryoichi; Takagi, Tetsuro; Hirooka, Koutaro; Kumagai, Sadatoshi

    The expansion of the renewable energy introduction is examined as measures for controlling global warming. Wind power generation is expected as effective power resource, but the negative impact from the difficulty of an unstable output is concerned. In recent years, WT generation with contract of cut-of with shorting adjusting power and with rechargeable battery for stabilizing control are examined, but the introduction has not been accelerated yet because there is an influence in WT generation entrepreneur's business. In this paper, we make a brief summary of relation between the fluctuation of wind power generation and stability of electric power operation, and two types of approach; cut-off contract and stabilization using rechargeable battery. For the stabilization using battery, there are two methods, one is reduction control and the other is constant control. We propose a new control method for constant control based on profit optimization considering WT generation forecast and its risk of deviation. We also propose the estimation method for the .limitation of battery installation. Simulation results show the efficiency of our proposed methods.

  3. Temporal Stability of Strength-Based Assessments: Test-Retest Reliability of Student and Teacher Reports

    Science.gov (United States)

    Romer, Natalie; Merrell, Kenneth W.

    2013-01-01

    This study focused on evaluating the temporal stability of self-reported and teacher-reported perceptions of students' social and emotional skills and assets. We used a test-retest reliability procedure over repeated administrations of the child, adolescent, and teacher versions of the "Social-Emotional Assets and Resilience Scales".…

  4. Assessment of structural stability of a degraded sandy clay loam soil ...

    African Journals Online (AJOL)

    The effects of bare, two legumes and four grasses cover treatments on the structural stability of a sandy clay loam Ultisol were studied within a two year period. The experiment was of a randomised complete block design with seven treatments. The legume treatments were Centrosema pubescens (Ce) and Pueraria ...

  5. Stochastic stability assessment of a semi-free piston engine generator concept

    Science.gov (United States)

    Kigezi, T. N.; Gonzalez Anaya, J. A.; Dunne, J. F.

    2016-09-01

    Small engines, as power generators with low-noise and vibration characteristics, are needed in two niche application areas: as electric vehicle range extenders and as domestic micro Combined Heat and Power systems. A recent semi-free piston design known as the AMOCATIC generator fully meets this requirement. The engine potentially allows for high energy conversion efficiencies at resonance derived from having a mass and spring assembly. As with free-piston engines in general, stability and control of piston motion has been cited as the prime challenge limiting the technology's widespread application. Using physical principles, we derive in this paper two important results: an energy balance criterion and a related general stability criterion for a semi-free piston engine. Control is achieved by systematically designing a Proportional Integral (PI) controller using a control-oriented engine model for which a specific stability condition is stated. All results are presented in closed form throughout the paper. Simulation results under stochastic pressure conditions show that the proposed energy balance, stability criterion, and PI controller, operate as predicted to yield stable engine operation at fixed compression ratio.

  6. Stability of Early Risk Assessment for Autism Spectrum Disorder in Preterm Infants

    Science.gov (United States)

    Yaari, Maya; Yitzhak, Neta; Harel, Ayelet; Friedlander, Edwa; Bar-Oz, Benjamin; Eventov-Friedman, Smadar; Mankuta, David; Gamliel, Ifat; Yirmiya, Nurit

    2016-01-01

    Stability and change in early autism spectrum disorder risk were examined in a cohort of 99 preterm infants (?34 weeks of gestation) using the Autism Observation Scale for Infants at 8 and 12 months and the Autism Diagnostic Observation Schedule--Toddler Module at 18 months. A total of 21 infants were identified at risk by the Autism Observation…

  7. Stochastic stability assessment of a semi-free piston engine generator concept

    International Nuclear Information System (INIS)

    Kigezi, T N; Anaya, J A Gonzalez; Dunne, J F

    2016-01-01

    Small engines, as power generators with low-noise and vibration characteristics, are needed in two niche application areas: as electric vehicle range extenders and as domestic micro Combined Heat and Power systems. A recent semi-free piston design known as the AMOCATIC generator fully meets this requirement. The engine potentially allows for high energy conversion efficiencies at resonance derived from having a mass and spring assembly. As with free-piston engines in general, stability and control of piston motion has been cited as the prime challenge limiting the technology's widespread application. Using physical principles, we derive in this paper two important results: an energy balance criterion and a related general stability criterion for a semi-free piston engine. Control is achieved by systematically designing a Proportional Integral (PI) controller using a control-oriented engine model for which a specific stability condition is stated. All results are presented in closed form throughout the paper. Simulation results under stochastic pressure conditions show that the proposed energy balance, stability criterion, and PI controller, operate as predicted to yield stable engine operation at fixed compression ratio. (paper)

  8. Assessment of factors and conditions influencing bank stability of future lakes

    Czech Academy of Sciences Publication Activity Database

    Spanilá, Tamara; Kudrna, Z.; John, V.; Hartvich, Filip; Chour, V.

    2006-01-01

    Roč. 3, č. 4 (2006), s. 67-76 ISSN 1214-9705 R&D Projects: GA AV ČR IAA3046305 Institutional research plan: CEZ:AV0Z30460519 Keywords : flooding of residual mining pits * dangerous geodynamic phenomena * stability of banks and slopes Subject RIV: DB - Geology ; Mineralogy

  9. A Microfluidic Method to Assess Emulsion Stability in Crude-Oil/Water Separators

    NARCIS (Netherlands)

    Krebs, T.; Schroën, C.G.P.H.; Boom, R.M.

    2011-01-01

    The control of emulsion stability and droplet size is of crucial importance for oil production, especially for the processes of crude/oil water separation and cleanup of produced water. To recover pure oil and water, coalescence between droplets needs to take place, the extent of which will depend

  10. Environmental Assessment for Slope Stabilization Projects at Fort MacArthur, San Pedro, California

    Science.gov (United States)

    2012-01-01

    effective in stabilizing slopes. The USAF and its consultants identified the most effective remedial measures that can be economically constructed within...consultants identified the most effective remedial measures that can be economically constructed with the physical and property boundary constraints...carbon tetrachloride, ammonia, hydrogen sulfide, hydrogen cyanide , and methane. The SCAB is not classified under CAAQS for any TACs (CARB 2011). EA

  11. Assessment of ploidy stability of the somatic embryogenesis process in Quercus suber L. using flow cytometry

    Czech Academy of Sciences Publication Activity Database

    Loureiro, J.; Pinto, G.; Lopes, T.; Doležel, Jaroslav; Santos, C.

    2005-01-01

    Roč. 221, - (2005), s. 815-822 ISSN 0032-0935 Institutional research plan: CEZ:AV0Z50380511 Keywords : Flow cytometry * ploidy stability * nuclear DNA content Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 3.108, year: 2005

  12. Degradation and stabilization of ice wedges: Implications for assessing risk of thermokarst in northern Alaska

    Science.gov (United States)

    Kanevskiy, Mikhail; Shur, Yuri; Jorgenson, Torre; Brown, Dana R. N.; Moskalenko, Nataliya; Brown, Jerry; Walker, Donald A.; Raynolds, Martha K.; Buchhorn, Marcel

    2017-11-01

    Widespread degradation of ice wedges has been observed during the last decades in numerous areas within the continuous permafrost zone of Eurasia and North America. To study ice-wedge degradation, we performed field investigations at Prudhoe Bay and Barrow in northern Alaska during 2011-2016. In each study area, a 250-m transect was established with plots representing different stages of ice-wedge degradation/stabilization. Field work included surveying ground- and water-surface elevations, thaw-depth measurements, permafrost coring, vegetation sampling, and ground-based LiDAR scanning. We described cryostratigraphy of frozen soils and stable isotope composition, analyzed environmental characteristics associated with ice-wedge degradation and stabilization, evaluated the vulnerability and resilience of ice wedges to climate change and disturbances, and developed new conceptual models of ice-wedge dynamics that identify the main factors affecting ice-wedge degradation and stabilization and the main stages of this quasi-cyclic process. We found significant differences in the patterns of ice-wedge degradation and stabilization between the two areas, and the patterns were more complex than those previously described because of the interactions of changing topography, water redistribution, and vegetation/soil responses that can interrupt or reinforce degradation. Degradation of ice wedges is usually triggered by an increase in the active-layer thickness during exceptionally warm and wet summers or as a result of flooding or disturbance. Vulnerability of ice wedges to thermokarst is controlled by the thickness of the intermediate layer of the upper permafrost, which overlies ice wedges and protects them from thawing. In the continuous permafrost zone, degradation of ice wedges rarely leads to their complete melting; and in most cases wedges eventually stabilize and can then resume growing, indicating a somewhat cyclic and reversible process. Stabilization of ice wedges

  13. Consideration of the restoring plan in subsidence prone areas through the development of ground stability assessment techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kwang-Soo; Kim, Im-Ho; Baek, Sang-Ho [Korea Institute of Geology Mining and Materials, Taejon (KR)] (and others)

    1999-12-01

    This report consists of 2 subjects. (1) Consideration of the restoring plan in subsidence prone areas through the development of ground stability assessment techniques : The number of mines at rest as well as closed have abruptly increased since the 1980's, which has caused subsidence problems around the mined areas. To protect such places from damage due to subsidence, it is necessary to develop the assessment techniques of ground stability and make restoration plan. To achieve this goal, the site investigation should have been conducted before the subsidence events occurred, but ground behaviors around the places where a vertical movement is expected and recognised in advance before the occurrence of the subsidence events. In this study ground stability analysis for the area surrounding the Moo-Geuk Mine, located close to a city, was conducted and the measurements were recorded. The objectives of the present study include, the development of a risk assessment technique for the subsidence using GIS tool, an evaluation of the numerical methods related to the site investigation and the ground stability analysis, the application of the numerical tools to the present problems. (2) Integration of coal mine data and use of remote sensing in investigation of coal mine area : This study attempt to integrate the previous geological and mining data to avoid confusions often occurred when accessing source data. And the investigation of underground mining place using remote sensing method is the other effort to assure the geographic locations of mining places as well as to find out unknown mining place. The sample region for examining the remote sensing method is the Chungnam coal field, which locates in the middle western part of South Korea. Detailed investigation was held on the Seongju area, locating north eastern part of the coal field. (author). 54 refs., tabs., figs.

  14. Protein Comparability Assessments and Potential Applicability of High Throughput Biophysical Methods and Data Visualization Tools to Compare Physical Stability Profiles

    Directory of Open Access Journals (Sweden)

    Mohammad A. Alsenaidy

    2014-03-01

    Full Text Available In this review, some of the challenges and opportunities encountered during protein comparability assessments are summarized with an emphasis on developing new analytical approaches to better monitor higher-order protein structures. Several case studies are presented using high throughput biophysical methods to collect protein physical stability data as function of temperature, agitation, ionic strength and/or solution pH. These large data sets were then used to construct empirical phase diagrams (EPDs, radar charts, and comparative signature diagrams (CSDs for data visualization and structural comparisons between the different proteins. Protein samples with different sizes, post-translational modifications, and inherent stability are presented: acidic fibroblast growth factor (FGF-1 mutants, different glycoforms of an IgG1 mAb prepared by deglycosylation, as well as comparisons of different formulations of an IgG1 mAb and granulocyte colony stimulating factor (GCSF. Using this approach, differences in structural integrity and conformational stability profiles were detected under stress conditions that could not be resolved by using the same techniques under ambient conditions (i.e., no stress. Thus, an evaluation of conformational stability differences may serve as an effective surrogate to monitor differences in higher-order structure between protein samples. These case studies are discussed in the context of potential utility in protein comparability studies.

  15. Protein comparability assessments and potential applicability of high throughput biophysical methods and data visualization tools to compare physical stability profiles.

    Science.gov (United States)

    Alsenaidy, Mohammad A; Jain, Nishant K; Kim, Jae H; Middaugh, C Russell; Volkin, David B

    2014-01-01

    In this review, some of the challenges and opportunities encountered during protein comparability assessments are summarized with an emphasis on developing new analytical approaches to better monitor higher-order protein structures. Several case studies are presented using high throughput biophysical methods to collect protein physical stability data as function of temperature, agitation, ionic strength and/or solution pH. These large data sets were then used to construct empirical phase diagrams (EPDs), radar charts, and comparative signature diagrams (CSDs) for data visualization and structural comparisons between the different proteins. Protein samples with different sizes, post-translational modifications, and inherent stability are presented: acidic fibroblast growth factor (FGF-1) mutants, different glycoforms of an IgG1 mAb prepared by deglycosylation, as well as comparisons of different formulations of an IgG1 mAb and granulocyte colony stimulating factor (GCSF). Using this approach, differences in structural integrity and conformational stability profiles were detected under stress conditions that could not be resolved by using the same techniques under ambient conditions (i.e., no stress). Thus, an evaluation of conformational stability differences may serve as an effective surrogate to monitor differences in higher-order structure between protein samples. These case studies are discussed in the context of potential utility in protein comparability studies.

  16. OECD/DOE/CEA VVER-1000 coolant transient (V1000CT) benchmark - a consistent approach for assessing coupled codes for RIA analysis

    International Nuclear Information System (INIS)

    Boyan D Ivanov; Kostadin N Ivanov; Eric Royer; Sylvie Aniel; Nikola Kolev; Pavlin Groudev

    2005-01-01

    Full text of publication follows: The Rod Ejection Accident (REA) and Main Steam Line Break (MSLB) are two of the most important Design Basis Accidents (DBA) for VVER-1000 exhibiting significant localized space-time effects. A consistent approach for assessing coupled three-dimensional (3-D) neutron kinetics/thermal hydraulics codes for these Reactivity Insertion Accidents (RIA) is to first validate the codes using the available plant test (measured) data and after that perform cross code comparative analysis for REA and MSLB scenarios. In the framework of joint effort between the Nuclear Energy Agency (NEA) of OECD, the United States Department of Energy (US DOE), and the Commissariat a l'Energie Atomique (CEA), France a coupled 3-D neutron kinetics/thermal hydraulics benchmark was defined. The benchmark is based on data from the Unit 6 of the Bulgarian Kozloduy Nuclear Power Plant (NPP). In performing this work the PSU, USA and CEA-Saclay, France have collaborated with Bulgarian organizations, in particular with the KNPP and the INRNE. The benchmark consists of two phases: Phase 1: Main Coolant Pump Switching On; Phase 2: Coolant Mixing Tests and MSLB. In addition to the measured (experiment) scenario, an extreme calculation scenario was defined for better testing 3-D neutronics/thermal-hydraulics techniques: rod ejection simulation with control rod being ejected in the core sector cooled by the switched on MCP. Since the previous coupled code benchmarks indicated that further development of the mixing computation models in the integrated codes is necessary, a coolant mixing experiment and MSLB transients are selected for simulation in Phase 2 of the benchmark. The MSLB event is characterized by a large asymmetric cooling of the core, stuck rods and a large primary coolant flow variation. Two scenarios are defined in Phase 2: the first scenario is taken from the current licensing practice and the second one is derived from the original one using aggravating

  17. Stability Assessment and Tuning of an Adaptively Augmented Classical Controller for Launch Vehicle Flight Control

    Science.gov (United States)

    VanZwieten, Tannen; Zhu, J. Jim; Adami, Tony; Berry, Kyle; Grammar, Alex; Orr, Jeb S.; Best, Eric A.

    2014-01-01

    Recently, a robust and practical adaptive control scheme for launch vehicles [ [1] has been introduced. It augments a classical controller with a real-time loop-gain adaptation, and it is therefore called Adaptive Augmentation Control (AAC). The loop-gain will be increased from the nominal design when the tracking error between the (filtered) output and the (filtered) command trajectory is large; whereas it will be decreased when excitation of flex or sloshing modes are detected. There is a need to determine the range and rate of the loop-gain adaptation in order to retain (exponential) stability, which is critical in vehicle operation, and to develop some theoretically based heuristic tuning methods for the adaptive law gain parameters. The classical launch vehicle flight controller design technics are based on gain-scheduling, whereby the launch vehicle dynamics model is linearized at selected operating points along the nominal tracking command trajectory, and Linear Time-Invariant (LTI) controller design techniques are employed to ensure asymptotic stability of the tracking error dynamics, typically by meeting some prescribed Gain Margin (GM) and Phase Margin (PM) specifications. The controller gains at the design points are then scheduled, tuned and sometimes interpolated to achieve good performance and stability robustness under external disturbances (e.g. winds) and structural perturbations (e.g. vehicle modeling errors). While the GM does give a bound for loop-gain variation without losing stability, it is for constant dispersions of the loop-gain because the GM is based on frequency-domain analysis, which is applicable only for LTI systems. The real-time adaptive loop-gain variation of the AAC effectively renders the closed-loop system a time-varying system, for which it is well-known that the LTI system stability criterion is neither necessary nor sufficient when applying to a Linear Time-Varying (LTV) system in a frozen-time fashion. Therefore, a

  18. Spectroscopic classification of transients

    DEFF Research Database (Denmark)

    Stritzinger, M. D.; Fraser, M.; Hummelmose, N. N.

    2017-01-01

    We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017.......We report the spectroscopic classification of several transients based on observations taken with the Nordic Optical Telescope (NOT) equipped with ALFOSC, over the nights 23-25 August 2017....

  19. Extending the Cooperative Phenotype: Assessing the Stability of Cooperation across Countries.

    Science.gov (United States)

    Reigstad, Amanda G; Strømland, Eirik A; Tinghög, Gustav

    2017-01-01

    This paper studies whether individual cooperation is stable across settings and over time. Involving more than 7,000 subjects on two different continents, this study documents positive correlation in cooperative behavior across economic games in Norway, Sweden, Austria, and the United States. The game measures also correlate with a tendency to make deontological judgments in moral dilemmas, and display of general trust toward strangers. Using time-variation in the data, we test whether temporal stability of behavior is similar in the United States and Norway, and find similar stability estimates for both the American and Norwegian samples. The findings here provide further evidence of the existence of a stable behavioral inclination toward prosociality - a "cooperative phenotype," as it has recently been termed. Also in line with previous research, we find that punishment and cooperation seem to be uncorrelated.

  20. Extending the Cooperative Phenotype: Assessing the Stability of Cooperation across Countries

    Directory of Open Access Journals (Sweden)

    Amanda G. Reigstad

    2017-11-01

    Full Text Available This paper studies whether individual cooperation is stable across settings and over time. Involving more than 7,000 subjects on two different continents, this study documents positive correlation in cooperative behavior across economic games in Norway, Sweden, Austria, and the United States. The game measures also correlate with a tendency to make deontological judgments in moral dilemmas, and display of general trust toward strangers. Using time-variation in the data, we test whether temporal stability of behavior is similar in the United States and Norway, and find similar stability estimates for both the American and Norwegian samples. The findings here provide further evidence of the existence of a stable behavioral inclination toward prosociality – a “cooperative phenotype,” as it has recently been termed. Also in line with previous research, we find that punishment and cooperation seem to be uncorrelated.

  1. Thermodynamic assessment of the stabilization effect in deformed shape memory alloy martensite

    International Nuclear Information System (INIS)

    Kato, Hiroyuki; Yasuda, Yohei; Sasaki, Kazuaki

    2011-01-01

    When a martensitic shape memory alloy is deformed, the reverse transformation occurs at higher temperature than that of undeformed martensite. This is a typical case of the stabilization effect of martensite that is commonly observed in shape memory alloys. Regarding previous results measured by electric resistance and/or dilatometoric methods in NiTi and CuAlNi shape memory alloys, this study has performed calorimetric measurement in these alloys in order to re-examine the stabilization effect in terms of thermodynamics. Experimental evidence for appreciable changes in the reverse transformation temperature due to variant change of the martensite is presented. The elastic energy stored in the deformed martensite and the irreversible energy dissipated during the reverse transformation are estimated from the transformation temperatures, the stress-strain curves of the martensite and the latent heat of transformation. The temperatures of the reverse martensitic transformation have been related to these energies in explicit form.

  2. Experimental assessment of dry stone retaining wall stability on a rigid foundation

    OpenAIRE

    Villemus , B.; Morel , J.C.; Boutin , C.

    2007-01-01

    International audience; Dry stone masonry retaining walls are present in the majority of mountainous areas all around the world, but the technique is marginal today in developed countries. The emergence of the concept of sustainable development calls for renewed use of this technique, both for the repair of existing retaining walls and the building of new ones. The objective of this research was to seek the knowledge necessary to ensure the stability of these structures, using experimental in...

  3. Random matrix theory filters in portfolio optimisation: A stability and risk assessment

    Science.gov (United States)

    Daly, J.; Crane, M.; Ruskin, H. J.

    2008-07-01

    Random matrix theory (RMT) filters, applied to covariance matrices of financial returns, have recently been shown to offer improvements to the optimisation of stock portfolios. This paper studies the effect of three RMT filters on the realised portfolio risk, and on the stability of the filtered covariance matrix, using bootstrap analysis and out-of-sample testing. We propose an extension to an existing RMT filter, (based on Krzanowski stability), which is observed to reduce risk and increase stability, when compared to other RMT filters tested. We also study a scheme for filtering the covariance matrix directly, as opposed to the standard method of filtering correlation, where the latter is found to lower the realised risk, on average, by up to 6.7%. We consider both equally and exponentially weighted covariance matrices in our analysis, and observe that the overall best method out-of-sample was that of the exponentially weighted covariance, with our Krzanowski stability-based filter applied to the correlation matrix. We also find that the optimal out-of-sample decay factors, for both filtered and unfiltered forecasts, were higher than those suggested by Riskmetrics [J.P. Morgan, Reuters, Riskmetrics technical document, Technical Report, 1996. http://www.riskmetrics.com/techdoc.html], with those for the latter approaching a value of α=1. In conclusion, RMT filtering reduced the realised risk, on average, and in the majority of cases when tested out-of-sample, but increased the realised risk on a marked number of individual days-in some cases more than doubling it.

  4. Assessment of the availability of As and Pb in soils after in situ stabilization.

    Science.gov (United States)

    Zhang, Wanying; Yang, Jie; Li, Zhongyuan; Zhou, Dongmei; Dang, Fei

    2017-10-01

    The in situ stabilization has been widely used to remediate metal-contaminated soil. However, the long-term retaining performance of heavy metals and the associated risk after in situ stabilization remains unclear and has evoked amounting concerns. Here, Pb- or As-contaminated soil was stabilized by a commercial amendment. The availability of Pb and As after in situ stabilization were estimated by ten different in vitro chemical extractions and DGT technique. After amendment application, a significant decline in extractable Pb or As was observed in treatments of Milli-Q water, 0.01 M CaCl 2 , 0.1 M NaNO 3 , 0.05 M (NH 4 ) 2 SO 4 , and 0.43 M HOAc. Potential available metal(loid)s determined by DGT also showed remarkable reduction. Meanwhile, the results of in vivo uptake assays demonstrated that Pb concentrations in shoots of ryegrass Lolium perenne L. declined to 12% of the control samples, comparable to the extraction ratio of 0.1 M NaNO 3 (15.8%) and 0.05 M (NH 4 ) 2 SO 4 (17.3%). For As-contaminated soil, 0.43 M HOAC provided a better estimation of relative phytoavailability (64.6 vs. 65.4% in ryegrass) compared to other extraction methods. We propose that 0.1 M NaNO 3 or 0.05 M (NH 4 ) 2 SO 4 for Pb and 0.43 M HOAc for As may serve as surrogate measures to estimate the lability of metal(loid)s after soil remediation of the tested contaminated soils. Further studies over a wider range of soil types and amendments are necessary to validate extraction methods.

  5. Slope Stability Assessment of the Sarcheshmeh Landslide, Northeast Iran, Investigated Using InSAR and GPS Observations

    Directory of Open Access Journals (Sweden)

    Mahdi Motagh

    2013-07-01

    Full Text Available The detection and monitoring of mass movement of susceptible slopes plays a key role in mitigating hazards and potential damage associated with creeping slopes and landslides. In this paper, we use observations from both Interferometric Synthetic Aperture Radar (InSAR and Global Positioning System (GPS to assess the slope stability of the Sarcheshmeh ancient landslide in the North Khorasan province of northeast Iran. InSAR observations were obtained by the time-series analysis of Envisat SAR images covering 2004–2006, whereas repeated GPS observations were conducted by campaign measurements during 2010–2012. Surface displacement maps of the Sarcheshmeh landslide obtained from InSAR and GPS are both indicative of slope stability. Hydrogeological analysis suggests that the multi-year drought and lower than average precipitation levels over the last decade might have contributed to the current dormancy of the Sarcheshmeh landslide.

  6. An assessment of the impact of energy insecurity on state stability in India

    International Nuclear Information System (INIS)

    Varigonda, Kesava Chandra

    2013-01-01

    This paper studies the relation between energy insecurity and state stability in India. Primarily it looks at the ways in which specific aspects of energy insecurity impact the stability of the Indian state. The paper contends that energy insecurity in the form of fuel supply and electricity supply insecurities gives rise to social and political instability, which in extreme forms could lead to state destabilisation. A combination of inadequate and unreasonably priced fuel supply gives rise to instability in the social and political spheres; if the fuel supply is also unreliable, it could lead to chronic socio-political instability. Likewise, a combination of inadequate and unreliable electricity supply could, in certain instances, cause limited social instability; if this is also accompanied by an electricity price hike, it could lead to chronic socio-political instability. Chronic socio-political instability in an already weakened state could facilitate state destabilisation. - Highlights: • Studies the impact of energy insecurity on the stability of the Indian state. • Secondary sources from press releases of the last three decades are examined. • Fuel supply and electricity supply insecurities cause socio-political instability. • Chronic socio-political instability may lead to destabilisation of a week state

  7. Moving from laboratory to real life conditions: Influence on the assessment of variability and stability of gait.

    Science.gov (United States)

    Tamburini, Paola; Storm, Fabio; Buckley, Chris; Bisi, Maria Cristina; Stagni, Rita; Mazzà, Claudia

    2018-01-01

    The availability of wearable sensors allows shifting gait analysis from the traditional laboratory settings, to daily life conditions. However, limited knowledge is available about whether alterations associated to different testing environment (e.g. indoor or outdoor) and walking protocols (e.g. free or controlled), result from actual differences in the motor behaviour of the tested subjects or from the sensitivity to these changes of the indexes adopted for the assessment. In this context, it was hypothesized that testing environment and walking protocols would not modify motor control stability in the gait of young healthy adults, who have a mature and structured gait pattern, but rather the variability of their motor pattern. To test this hypothesis, data from trunk and shank inertial sensors were collected from 19 young healthy participants during four walking tasks in different environments (indoor and outdoor) and in both controlled (i.e. following a predefined straight path) and free conditions. Results confirmed what hypothesized: variability indexes (Standard deviation, Coefficient of variation and Poincaré plots) were significantly influenced by both environment and walking conditions. Stability indexes (Harmonic ratio, Short term Lyapunov exponents, Recurrence quantification analysis and Sample entropy), on the contrary, did not highlight any change in the motor control. In conclusion, this study highlighted an influence of environment and testing condition on the assessment of specific characteristics of gait (i.e. variability and stability). In particular, for young healthy adults, both environment and testing conditions affect gait variability indexes, whereas neither affect gait stability indexes. Copyright © 2017. Published by Elsevier B.V.

  8. Fast relaxation transients in a kicked damped oscillator

    Energy Technology Data Exchange (ETDEWEB)

    Urquizu, Merce [Laboratori d' Estudis Geofisics ' Eduard Fontsere' , IEC, Barcelona (Spain); Correig, Antoni M. [Departament d' Astronomical i Meteorologia, Laboratori d' Estudis Geofisics Eduard Fontsere, UB Marti Franques 1, E-08028 Barcelona (Spain) and Laboratori d' Estudis Geofisics ' Eduard Fontsere' , IEC, Barcelona (Spain)]. E-mail: ton.correig@am.ub.es

    2007-08-15

    Although nonlinear relaxation transients are very common in nature, very few studies are devoted to its characterization, mainly due to its short time duration. In this paper, we present a study about the nature of relaxation transients in a kicked damped oscillator, in which transients are generated in terms of continuous fast changes in the parameters of the system. We have found that transient dynamics can be described, rather than in terms of bifurcation dynamics, in terms of instantaneous stretching factors, which are related to the stability of fixed points of the corresponding stroboscopic maps.

  9. Hybrid dynamic stabilization: a biomechanical assessment of adjacent and supraadjacent levels of the lumbar spine.

    Science.gov (United States)

    Mageswaran, Prasath; Techy, Fernando; Colbrunn, Robb W; Bonner, Tara F; McLain, Robert F

    2012-09-01

    The object of this study was to evaluate the effect of hybrid dynamic stabilization on adjacent levels of the lumbar spine. Seven human spine specimens from T-12 to the sacrum were used. The following conditions were implemented: 1) intact spine; 2) fusion of L4-5 with bilateral pedicle screws and titanium rods; and 3) supplementation of the L4-5 fusion with pedicle screw dynamic stabilization constructs at L3-4, with the purpose of protecting the L3-4 level from excessive range of motion (ROM) and to create a smoother motion transition to the rest of the lumbar spine. An industrial robot was used to apply continuous pure moment (± 2 Nm) in flexion-extension with and without a follower load, lateral bending, and axial rotation. Intersegmental rotations of the fused, dynamically stabilized, and adjacent levels were measured and compared. In flexion-extension only, the rigid instrumentation at L4-5 caused a 78% decrease in the segment's ROM when compared with the intact specimen. To compensate, it caused an increase in motion at adjacent levels L1-2 (45.6%) and L2-3 (23.2%) only. The placement of the dynamic construct at L3-4 decreased the operated level's ROM by 80.4% (similar stability as the fusion at L4-5), when compared with the intact specimen, and caused a significant increase in motion at all tested adjacent levels. In flexion-extension with a follower load, instrumentation at L4-5 affected only a subadjacent level, L5-sacrum (52.0%), while causing a reduction in motion at the operated level (L4-5, -76.4%). The dynamic construct caused a significant increase in motion at the adjacent levels T12-L1 (44.9%), L1-2 (57.3%), and L5-sacrum (83.9%), while motion at the operated level (L3-4) was reduced by 76.7%. In lateral bending, instrumentation at L4-5 increased motion at only T12-L1 (22.8%). The dynamic construct at L3-4 caused an increase in motion at T12-L1 (69.9%), L1-2 (59.4%), L2-3 (44.7%), and L5-sacrum (43.7%). In axial rotation, only the placement of

  10. Thermal stability of hepatitis E virus assessed by a molecular biological approach

    Directory of Open Access Journals (Sweden)

    Appel Bernd

    2011-10-01

    Full Text Available Abstract Background Hepatitis E virus (HEV is a pathogen of emerging concern in industrialized countries. The consumption of wild boar meat has been identified as one risk factor for autochthonous HEV infections. Only limited information is available about thermal stability of HEV, mainly due to the lack of rapid and efficient cell culture systems for measurement of HEV infectivity. Methods A molecular biological method was implemented in order to distinguish disassembled from intact viral particles using RNase treatment followed by quantitative real-time RT-PCR. The method was applied to a wild boar liver suspension containing HEV genotype 3. Results Time-course analyses indicated that the decline of protected RNA could be described by a biphasic model with an initial decrease followed by a stationary phase. The stationary phase was reached after 1 hour at 4°C, 3 days at 22°C and 7 days at 37°C with log reductions of 0.34, 0.45 and 1.24, respectively. Protected RNA was detectable until the end of the experiments at day 50 or 70. Heat exposure for 1 minute resulted in a log reduction of 0.48 at 70°C and increased with higher temperatures to 3.67 at 95°C. Although HEV infectivity titration by inoculation of the liver suspension onto three cell lines did not succeed, the results of the RNase-based method are in accordance with published cell culture-based data. Conclusions Measurement of intact viral particles using the RNase-based method may provide data on the stability of RNA viruses when cell culture-based infectivity titrations are not efficient or not available. The method enables processing of large sample numbers and may be suitable to estimate stability of HEV in different types of food.

  11. Fast Dynamic Simulation-Based Small Signal Stability Assessment and Control

    Energy Technology Data Exchange (ETDEWEB)

    Acharya, Naresh [General Electric Company, Fairfield, CT (United States); Baone, Chaitanya [General Electric Company, Fairfield, CT (United States); Veda, Santosh [General Electric Company, Fairfield, CT (United States); Dai, Jing [General Electric Company, Fairfield, CT (United States); Chaudhuri, Nilanjan [General Electric Company, Fairfield, CT (United States); Leonardi, Bruno [General Electric Company, Fairfield, CT (United States); Sanches-Gasca, Juan [General Electric Company, Fairfield, CT (United States); Diao, Ruisheng [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wu, Di [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Huang, Zhenyu [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Yu [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jin, Shuangshuang [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zheng, Bin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chen, Yousu [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-31

    Power grid planning and operation decisions are made based on simulation of the dynamic behavior of the system. Enabling substantial energy savings while increasing the reliability of the aging North American power grid through improved utilization of existing transmission assets hinges on the adoption of wide-area measurement systems (WAMS) for power system stabilization. However, adoption of WAMS alone will not suffice if the power system is to reach its full entitlement in stability and reliability. It is necessary to enhance predictability with "faster than real-time" dynamic simulations that will enable the dynamic stability margins, proactive real-time control, and improve grid resiliency to fast time-scale phenomena such as cascading network failures. Present-day dynamic simulations are performed only during offline planning studies, considering only worst case conditions such as summer peak, winter peak days, etc. With widespread deployment of renewable generation, controllable loads, energy storage devices and plug-in hybrid electric vehicles expected in the near future and greater integration of cyber infrastructure (communications, computation and control), monitoring and controlling the dynamic performance of the grid in real-time would become increasingly important. The state-of-the-art dynamic simulation tools have limited computational speed and are not suitable for real-time applications, given the large set of contingency conditions to be evaluated. These tools are optimized for best performance of single-processor computers, but the simulation is still several times slower than real-time due to its computational complexity. With recent significant advances in numerical methods and computational hardware, the expectations have been rising towards more efficient and faster techniques to be implemented in power system simulators. This is a natural expectation, given that the core solution algorithms of most commercial simulators were developed

  12. Assessment of soil stabilization by chemical extraction and bioaccumulation using earthworm, Eisenia fetida

    Science.gov (United States)

    Lee, Byung-Tae; Abd Aziz, Azilah; Han, Heop Jo; Kim, Kyoung-Woong

    2014-05-01

    Soil stabilization does not remove heavy metals from contaminated soil, but lowers their exposures to ecosystem. Thus, it should be evaluated by measuring the fractions of heavy metals which are mobile and/or bioavailable in soils. The study compared several chemical extractions which intended to quantify the mobile or bioaccessible fractions with uptake and bioaccumulation by earthworm, Eisenia fetida. Soil samples were taken from the abandoned mine area contaminated with As, Cd, Cu, Pb and/or Zn. To stabilize heavy metals, the soils were amended with limestone and steel slag at 5% and 2% (w/w), respectively. All chemical extractions and earthworm tests were applied to both the contaminated and the stabilized soils with triplicates. The chemical extractions consisted of six single extractions which were 0.01M CaCl2 (unbufferred), EDTA or DTPA (chelating), TCLP (acidic), Mehlich 3 (mixture), and aqua regia (peudo-total). Sequential extractions were also applied to fractionate heavy metals in soils. In earthworm tests, worms were exposed to the soils for uptake of heavy metals. After 28 days of exposure to soils, worms were transferred to clean soils for elimination. During the tests, three worms were randomly collected at proper sampling events. Worms were rinsed with DI water and placed on moist filter paper for 48 h for depuration. Filter paper was renewed at 24 h to prevent coprophagy. The worms were killed with liquid nitrogen, dried in the oven, and digested with aqua regia for ICP-MS analysis. In addition to the bioaccumulation, several toxicity endpoints were observed such as burrowing time, mortality, cocoon production, and body weight changes. Toxicokinetics was applied to determine the uptake and elimination heavy metals by the earthworms. Bioaccumulation factor (BAF) was estimated using total metal concentrations and body burdens. Pearson correlation and simple linear regression were applied to evaluate the relationship between metal fractions by single

  13. Numerical assessment of efficiency and control stability of an HTS synchronous motor

    Energy Technology Data Exchange (ETDEWEB)

    Xian Wei; Yuan Weijia; Coombs, T A, E-mail: wx210@cam.ac.u [Electronic, Power and Energy Conversion Group, Engineering Department, Cambridge University, 9 JJ Thomson Avenue, Cambridge CB3 0FA (United Kingdom)

    2010-06-01

    A high temperature superconducting (HTS) permanent magnet synchronous motor (PMSM) is designed and developed in Cambridge University. It is expected to become cost competitive with the conventional PMSM owing to its high efficiency, high power density, high torque density, etc. The structure and parameters of HTS PMSM are detailed. Both AC losses by transport current and applied filed in stator armature winding of HTS PMSM are also analyzed. Computed and simulated results of the characteristics of the HTS PMSM and conventional PMSM are compared. The improvement on stability of direct torque control (DTC) on the HTS PMSM is estimated, and proved by simulation on Matlab/Simulink.

  14. On the stability of nongyrotropic ion populations: A first (analytic and simulation) assessment

    International Nuclear Information System (INIS)

    Brinca, A.L.; Borda De Agua, L.; Winske, D.

    1993-01-01

    Nongyrotropic particle populations have been observed in various space plasmas, and invoked to explain different observations within space plasmas. The authors consider waves whose frequency is below the lower hybrid frequency. They look at the stability of such low frequency waves propagating in a magnetoplasma with nongyrotropic ion populations. They derive wave equations and dispersion relations. They find that the introduction of nongyrotropy results in the coupling of wave eigenmodes, and the enhancement of instability growth rates. They consider the question of the instability growth rates in this paper

  15. Evaluation of enhancements to Thevenin equivalent based methods for real-time voltage stability assessment

    DEFF Research Database (Denmark)

    Perez, Angel; Jóhannsson, Hjörtur; Østergaard, Jacob

    2014-01-01

    The possibilities offered by the use of Phasor Measurement Units (PMU) in real - time monitoring provide interesting ways to ensure secure operation of power systems. This paper studies the specific case of voltage stability and the possible improvements to the Thevenin equivalent methods, which...... is applied generally with local measurements. This paper uses the PMU measurements to calculate the grid transformation coefficients to obtain wide - area information. This is achieved by studying the generator's electromo tive force estimated using values in the coefficient transformation matrix...

  16. Uncertainty in real-time voltage stability assessment methods based on Thevenin equivalent due to PMU’s accuracy

    DEFF Research Database (Denmark)

    Perez, Angel; Møller, Jakob Glarbo; Jóhannsson, Hjörtur

    2014-01-01

    This article studies the influence of PMU’s accuracy in voltage stability assessment, considering the specific case of Th ́ evenin equivalent based methods that include wide-area information in its calculations. The objective was achieved by producing a set of synthesized PMU measurements from...... a time domain simulation and using the Monte Carlo method to reflect the accuracy for the PMUs. This is given by the maximum value for the Total Vector Error defined in the IEEE standard C37.118. Those measurements allowed to estimate the distribution pa- rameters (mean and standard deviation...

  17. Assessment of effectiveness of anti-seismic measures in stabilization project of ChNPP shelter object

    International Nuclear Information System (INIS)

    Kondrat'ev, S.N.; Kritskij, V.B.; Ryzhov, D.I.; Shugajlo, A.P.; Shugajlo, Al.P.; Prabkhakara, M.

    2004-01-01

    The major factors, which may lead to the collapse of the Shelter object (SO) civil structures, are extreme natural phenomena and among them earthquake. In order to raise the resistance of the SO civil structure to seismic and other significant loads and to reduce the risk of their collapse ChNPP requested KSK Consortium to develop the SO Detailed Design for stabilization. At the present work the results of assessment of anti-seismic measures are given based on results of a technical review of the Detailed Design

  18. Summary of transient analysis

    International Nuclear Information System (INIS)

    Saha, P.

    1984-01-01

    This chapter reviews the papers on the pressurized water reactor (PWR) and boiling water reactor (BWR) transient analyses given at the American Nuclear Society Topical Meeting on Anticipated and Abnormal Plant Transients in Light Water Reactors. Most of the papers were based on the systems calculations performed using the TRAC-PWR, RELAP5 and RETRAN codes. The status of the nuclear industry in the code applications area is discussed. It is concluded that even though comprehensive computer codes are available for plant transient analysis, there is still a need to exercise engineering judgment, simpler tools and even hand calculations to supplement these codes

  19. Assessing deep-seated landslide susceptibility using 3-D groundwater and slope-stability analyses, southwestern Seattle, Washington

    Science.gov (United States)

    Brien, Dianne L.; Reid, Mark E.

    2008-01-01

    In Seattle, Washington, deep-seated landslides on bluffs along Puget Sound have historically caused extensive damage to land and structures. These large failures are controlled by three-dimensional (3-D) variations in strength and pore-water pressures. We assess the slope stability of part of southwestern Seattle using a 3-D limit-equilibrium analysis coupled with a 3-D groundwater flow model. Our analyses use a high-resolution digital elevation model (DEM) combined with assignment of strength and hydraulic properties based on geologic units. The hydrogeology of the Seattle area consists of a layer of permeable glacial outwash sand that overlies less permeable glacial lacustrine silty clay. Using a 3-D groundwater model, MODFLOW-2000, we simulate a water table above the less permeable units and calibrate the model to observed conditions. The simulated pore-pressure distribution is then used in a 3-D slope-stability analysis, SCOOPS, to quantify the stability of the coastal bluffs. For wet winter conditions, our analyses predict that the least stable areas are steep hillslopes above Puget Sound, where pore pressures are elevated in the outwash sand. Groundwater flow converges in coastal reentrants, resulting in elevated pore pressures and destabilization of slopes. Regions predicted to be least stable include the areas in or adjacent to three mapped historically active deep-seated landslides. The results of our 3-D analyses differ significantly from a slope map or results from one-dimensional (1-D) analyses.

  20. Stability assessment of lycopene microemulsion prepared using tomato industrial waste against various processing conditions.

    Science.gov (United States)

    Amiri-Rigi, Atefeh; Abbasi, Soleiman

    2017-11-01

    Green separation techniques are growing at a greater rate than solvent extraction as a result of the constant consumer drive to 'go natural'. Considering the increasing evidence of the health benefits of lycopene and massive tomato industrial waste, in the present study, lycopene was extracted from tomato industrial waste using microemulsion technique and its mean droplet size and size distribution was determined. Moreover, the effects of pasteurization, sterilization, freeze-thaw cycles and ultraviolet (UV) irradiation on the thermodynamic stability, turbidity and lycopene concentration of the lycopene microemulsion were monitored. Freeze-thaw cycles, pasteurization and short exposure to UV irradiation showed no or negligible influence on lycopene content and turbidity of the microemulsion. However, long exposure to UV (260 min) reduced the lycopene content and turbidity by 34% and 10%, respectively. HHST (higher-heat shorter-time) and sterilization also reduced lycopene content (25%) and increased turbidity (32%). The lycopene microemulsion showed satisfactory stability over a process where its monodispersity and nanosize could be of potential advantage to the food and related industries. Regarding the carcinogenicity of synthetic colourants, potential applications of the lycopene microemulsion include in soft drinks and minced meat, which would result in a better colour and well-documented health-promoting qualities. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  1. Resveratrol production in bioreactor: Assessment of cell physiological states and plasmid segregational stability

    Directory of Open Access Journals (Sweden)

    Margarida S. Afonso

    2015-03-01

    Full Text Available Resveratrol is a plant secondary metabolite commonly found in peanuts and grapevines with significant health benefits. Recombinant organisms can produce large amounts of resveratrol and, in this work, Escherichia coli BW27784 was used to produce resveratrol in bioreactors while monitoring cell physiology and plasmid stability through flow cytometry and real-time qPCR, respectively. Initially, the influence of culture conditions and precursor addition was evaluated in screening assays and the data gathered was used to perform the bioreactor assays, allowing the production of 160 μg/mL of resveratrol. Cellular physiology and plasmid instability affected the final resveratrol production, with lower viability and plasmid copy numbers associated with lower yields. In sum, this study describes new tools to monitor the bioprocess, evaluating the effect of culture conditions, and its correlation with cell physiology and plasmid segregational stability, in order to define a viable and scalable bioprocess to fulfill the need for larger quantities of resveratrol.

  2. Natural Stabilized Earth Panels versus Conventional Façade Systems. Economic and Environmental Impact Assessment

    Directory of Open Access Journals (Sweden)

    Carmen Galán-Marín

    2018-03-01

    Full Text Available More effective construction technologies are needed nowadays in order to reduce construction energy consumption during the life-cycle of buildings. Besides which, it is necessary to consider the economic feasibility and associated costs within the framework of these alternative technologies so as to favouring their practical implementation in the construction sector. In this sense, this paper presents an economic and environmental comparison of a new non-bearing façade construction solution based on the extruded unfired stabilized clay panels as opposed to three traditional solutions with similar physical, thermal, and aesthetic characteristics in terms of the exterior cladding. The proposed panels are a sandwich type configuration with an intermediate insulating material and two exterior pieces manufactured by extrusion with raw earth stabilized with alginate and animal wool fibers. In this paper, details of the constructive technology of the system are provided. From the results obtained, it is possible to conclude that the solution is a valid alternative from the environmental point of view, considerably reducing the Global Warming Potential and the Cumulative Energy Demand. And although the environmental improvement of the system can be considered the primary objective of this investigation, on the other hand, once executed, it will also be a competitive constructive technology from the perspective of the system’s final costs.

  3. Assessment of environmental stability of agroserous soil according to indicator of energy potential of organic substances

    Science.gov (United States)

    Murtazina, S. G.; Gaffarova, L. G.; Murtazin, MG

    2018-01-01

    Studies of the group and fractional composition of humus have determineded that the long-term use of soil (for 20 years) without the use of fertilizers (control) leads to a decrease in the content of humic acids and fulvic acids relative to the initial soil, which indicates an increase in mineralization of the soil humus. Under the influence of a long application of high doses of mineral fertilizers, the content of mobile fractions of humic and fulvic acids in the field rotation increases in the humus content. In systems of agriculture that are not balanced by organic matter, which are predominant in most farms of the Republic of Tatarstan, the use of very high doses of potassium fertilizers is not justified energetically. To compensate for losses of humus and its energy potential in calculating organic fertilizers on backgrounds with high doses of mineral fertilizers, the humification coefficients of organic residues should be increased by 30-40% during the rotational period of 5-6 years, which will reduce the loss of energy reserves and thereby improve the ecological stability of soils and the stability of agricultural landscapes

  4. Transient coupled calculations of the Molten Salt Fast Reactor using the Transient Fission Matrix approach

    Energy Technology Data Exchange (ETDEWEB)

    Laureau, A., E-mail: laureau.axel@gmail.com; Heuer, D.; Merle-Lucotte, E.; Rubiolo, P.R.; Allibert, M.; Aufiero, M.

    2017-05-15

    Highlights: • Neutronic ‘Transient Fission Matrix’ approach coupled to the CFD OpenFOAM code. • Fission Matrix interpolation model for fast spectrum homogeneous reactors. • Application for coupled calculations of the Molten Salt Fast Reactor. • Load following, over-cooling and reactivity insertion transient studies. • Validation of the reactor intrinsic stability for normal and accidental transients. - Abstract: In this paper we present transient studies of the Molten Salt Fast Reactor (MSFR). This generation IV reactor is characterized by a liquid fuel circulating in the core cavity, requiring specific simulation tools. An innovative neutronic approach called “Transient Fission Matrix” is used to perform spatial kinetic calculations with a reduced computational cost through a pre-calculation of the Monte Carlo spatial and temporal response of the system. Coupled to this neutronic approach, the Computational Fluid Dynamics code OpenFOAM is used to model the complex flow pattern in the core. An accurate interpolation model developed to take into account the thermal hydraulics feedback on the neutronics including reactivity and neutron flux variation is presented. Finally different transient studies of the reactor in normal and accidental operating conditions are detailed such as reactivity insertion and load following capacities. The results of these studies illustrate the excellent behavior of the MSFR during such transients.

  5. Transient coupled calculations of the Molten Salt Fast Reactor using the Transient Fission Matrix approach

    International Nuclear Information System (INIS)

    Laureau, A.; Heuer, D.; Merle-Lucotte, E.; Rubiolo, P.R.; Allibert, M.; Aufiero, M.

    2017-01-01

    Highlights: • Neutronic ‘Transient Fission Matrix’ approach coupled to the CFD OpenFOAM code. • Fission Matrix interpolation model for fast spectrum homogeneous reactors. • Application for coupled calculations of the Molten Salt Fast Reactor. • Load following, over-cooling and reactivity insertion transient studies. • Validation of the reactor intrinsic stability for normal and accidental transients. - Abstract: In this paper we present transient studies of the Molten Salt Fast Reactor (MSFR). This generation IV reactor is characterized by a liquid fuel circulating in the core cavity, requiring specific simulation tools. An innovative neutronic approach called “Transient Fission Matrix” is used to perform spatial kinetic calculations with a reduced computational cost through a pre-calculation of the Monte Carlo spatial and temporal response of the system. Coupled to this neutronic approach, the Computational Fluid Dynamics code OpenFOAM is used to model the complex flow pattern in the core. An accurate interpolation model developed to take into account the thermal hydraulics feedback on the neutronics including reactivity and neutron flux variation is presented. Finally different transient studies of the reactor in normal and accidental operating conditions are detailed such as reactivity insertion and load following capacities. The results of these studies illustrate the excellent behavior of the MSFR during such transients.

  6. Personality Stability from Childhood to Midlife: Relating Teachers’ Assessments in Elementary School to Observer- and Self-Ratings 40 Years Later

    Science.gov (United States)

    Edmonds, Grant W.; Goldberg, Lewis R.; Hampson, Sarah E.; Barckley, Maureen

    2013-01-01

    We report on the longitudinal stability of personality traits across an average 40 years in the Hawaii Personality and Health Cohort relating childhood teacher assessments of personality to adult self- and observer- reports. Stabilities based on self-ratings in adulthood were compared to those measured by the Structured Interview for the Five-Factor Model (SIFFM; Trull & Widiger, 1997), and trait ratings completed by interviewers. Although convergence between self-reports and observer-ratings was modest, childhood traits demonstrated similar levels of stability across methods in adulthood. Extraversion and Conscientiousness generally showed higher stabilities, whereas Neuroticism showed none. For Agreeableness and Intellect/Openness, stability was highest when assessed with observer-ratings. These findings are discussed in terms of differences in trait evaluativeness and observability across measurement methods. PMID:24039315

  7. Transients: The regulator's view

    International Nuclear Information System (INIS)

    Sheron, B.W.; Speis, T.P.

    1984-01-01

    This chapter attempts to clarify the basis for the regulator's concerns for transient events. Transients are defined as both anticipated operational occurrences and postulated accidents. Recent operational experience, supplemented by improved probabilistic risk analysis methods, has demonstrated that non-LOCA transient events can be significant contributors to overall risk. Topics considered include lessons learned from events and issues, the regulations governing plant transients, multiple failures, different failure frequencies, operator errors, and public pressure. It is concluded that the formation of Owners Groups and Regulatory Response Groups within the owners groups are positive signs of the industry's concern for safety and responsible dealing with the issues affecting both the US NRC and the industry

  8. Probabilistic stability and "tall" wind profiles: theory and method for use in wind resource assessment

    DEFF Research Database (Denmark)

    Kelly, Mark C.; Troen, Ib

    2016-01-01

    A model has been derived for calculating the aggregate effects of stability and the finite height of the planetary boundary layer upon the long-term mean wind profile. A practical implementation of this probabilistic extended similarity-theory model is made, including its incorporation within...... to the methodology. Results of the modeling are shown for a number of sites, with discussion of the models’ efficacy and the relative improvement shown by the new model, for situations where a user lacks local heat flux information, as well as performance of the new model using measured flux statistics. Further...... the European Wind Atlas (EWA) methodology for site-to-site application. Theoretical and practical implications of the EWA methodology are also derived and described, including unprecedented documentation of the theoretical framework encompassing vertical extrapolation, as well as some improvement...

  9. Transient multivariable sensor evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Vilim, Richard B.; Heifetz, Alexander

    2017-02-21

    A method and system for performing transient multivariable sensor evaluation. The method and system includes a computer system for identifying a model form, providing training measurement data, generating a basis vector, monitoring system data from sensor, loading the system data in a non-transient memory, performing an estimation to provide desired data and comparing the system data to the desired data and outputting an alarm for a defective sensor.

  10. Turbofan compressor dynamics during afterburner transients

    Science.gov (United States)

    Kurkov, A. P.

    1976-01-01

    The effects of afterburner light-off and shut-down transients on the compressor stability are investigated. The reported experimental results are based on detailed high response pressure and temperature measurements on the TF30-P-3 turbofan engine. The tests were performed in an altitude test chamber simulating high altitude engine operation. It is shown that during both types of transients, flow breaks down in the forward part of the fan bypass duct. At a sufficiently low engine inlet pressure this resulted in a compressor stall. Complete flow breakdown within the compressor was preceded by a rotating stall. At some locations in the compressor, rotating stall cells initially extended only through part of the blade span. For the shutdown transient the time between first and last detected occurrence of rotating stall is related to the flow Reynolds number. An attempt was made to deduce the number and speed of propagation of rotating stall cells.

  11. COMPARATIVE ASSESSMENT OF RICE HUSK ASH, POWDERED GLASS AND CEMENT AS LATERITIC SOIL STABILIZERS

    Directory of Open Access Journals (Sweden)

    Adebisi Ridwan

    2016-10-01

    Full Text Available This paper compares the stabilizing effects of three different materials, namely: rice husk ash, powdered glass, and cement on the properties of lateritic soil. The basic properties of the lateritic soil were first obtained through colour, moisture content determination, specific gravity, particle size distribution and Atterberg limits tests. Each of the stabilizing materials was then mixed with the lateritic soil in varying percentages of 2.5%, 5%, 7.5%, 10%, 12.5% and 15% by weight of the soil. Thereafter, compaction and California bearing ratio (CBR tests were carried out on the sample mixes to determine the effects of the materials on the lateritic soil. Chemical tests were also carried out on the samples to determine their percentage oxides composition. The compaction test showed that the highest maximum dry densities (MDD obtained for the mixed samples were 2.32 g/cm3 (at 2.5% cement addition, 2.28g/cm3 (at 5% powdered glass (PG addition and 2.18 g/cm3 (at 5% rice husk ash (RHA addition with corresponding optimum moisture contents (OMC of 10.06%, 14.3% and 12.31% respectively. The CBR tests showed that the CBR values increased in all cases as the materials were added with those of the cement and powdered glass giving the highest values and showing close semblance under unsoaked conditions. The chemical test showed that the significant oxides present in the cement, powdered glass and rice husk ash were CaO (53.60%, SiO2 (68.45% and SiO2 (89.84% respectively.

  12. Stability and variability of virulence of Phytophthorainfestans assessed in a ring test across European laboratories

    NARCIS (Netherlands)

    Andrivon, D.; Avendaño-Córcoles, J.; Cameron, A.M.; Raaij, van H.M.G.

    2011-01-01

    Determining virulence towards race-specific resistance genes is a prerequisite to understanding the response of pathogen populations to resistant cultivars, and therefore to assess the durability of these resistance genes and the performance of resistance management strategies. In Phytophthora

  13. Assessment of implant stability during various stages of healing placed immediately following extraction in an overdenture situation

    Directory of Open Access Journals (Sweden)

    Ashwin Thomas Koshy

    2017-01-01

    Full Text Available To assess the implant stability during different stages of healing in an immediate loaded implant soon after extraction. A 73-year-old female came with a chief complaint of bad smell and irritation in her lower front gum region. On examination, she was found to be completely edentulous in the maxillary arch and partially edentulous in the mandibular arch with only the canines present bilaterally. The posterior mandibular ridge was severely resorbed and hence could not be treated with a conventional mandibular complete denture. Considering the age of the patient and the preference of only a single surgical visit, we decided to plan for a conventional maxillary denture against an implant supported mandibular overdenture with two implants placed immediately after extraction of canines. The stability of these implants was assessed during the early phases of healing with the help of a resonance frequency analysis method (RFA using Osstell ISQ™. During the healing phase, implant stability quotient (ISQ values decrease by 4–5 values after installation with the lowest values at the 1st week postplacement. Following this, the ISQ values increased steadily for all implants up to 16 weeks. No significant differences were noted over time. At placement, the mean ISQ values at 33 and 43 regions were 74 and 75.2, respectively. The mean lowest ISQ values recorded at the 1st week were 58.8 and 65.4, respectively. At 16 weeks, the mean ISQ values were 70.5 and 67.9, respectively. The survival of such immediately placed implants, which are later used as overdenture supported implants, are highly predictable when the surgical and prosthetic part is done meticulously. However, there needs future studies oriented to understand better the healing pattern of immediately placed implants in extraction sockets, which would guide the clinician with the optimal loading time.

  14. The course of transient hypochondriasis.

    Science.gov (United States)

    Barsky, A J; Cleary, P D; Sarnie, M K; Klerman, G L

    1993-03-01

    This study examined the longitudinal course of patients known to have had a previous episode of transient hypochondriasis. Twenty-two transiently hypochondriacal patients and 24 nonhypochondriacal patients from the same general medical clinic were reexamined after an average of 22 months with the use of self-report questionnaires, structured diagnostic interviews, and medical record review. The hypochondriacal patients continued to manifest significantly more hypochondriacal symptoms, more somatization, and more psychopathological symptoms at follow-up. They also reported significantly more amplification of bodily sensations and more functional disability and utilized more medical care. These differences persisted after control for differences in medical morbidity and marital status. Only one hypochondriacal patient, however, had a DSM-III-R diagnosis of hypochondriasis at follow-up. Multivariate analyses revealed that the only significant predictors of hypochondriacal symptoms at follow-up were hypochondriacal symptoms and the tendency to amplify bodily sensations at the baseline evaluation. Hypochondriacal symptoms appear to have some temporal stability: patients who experienced hypochondriacal episodes at the beginning of the study were significantly more hypochondriacal 2 years later than comparison patients. They were not, however, any more likely to develop DSM-III-R-defined hypochondriasis. Thus, hypochondriacal symptoms may be distinct from the axis I disorder. The data are also compatible with the hypothesis that preexisting amplification of bodily sensations is an important predictor of subsequent hypochondriacal symptoms.

  15. Transient virulence of emerging pathogens.

    Science.gov (United States)

    Bolker, Benjamin M; Nanda, Arjun; Shah, Dharmini

    2010-05-06

    Should emerging pathogens be unusually virulent? If so, why? Existing theories of virulence evolution based on a tradeoff between high transmission rates and long infectious periods imply that epidemic growth conditions will select for higher virulence, possibly leading to a transient peak in virulence near the beginning of an epidemic. This transient selection could lead to high virulence in emerging pathogens. Using a simple model of the epidemiological and evolutionary dynamics of emerging pathogens, along with rough estimates of parameters for pathogens such as severe acute respiratory syndrome, West Nile virus and myxomatosis, we estimated the potential magnitude and timing of such transient virulence peaks. Pathogens that are moderately evolvable, highly transmissible, and highly virulent at equilibrium could briefly double their virulence during an epidemic; thus, epidemic-phase selection could contribute significantly to the virulence of emerging pathogens. In order to further assess the potential significance of this mechanism, we bring together data from the literature for the shapes of tradeoff curves for several pathogens (myxomatosis, HIV, and a parasite of Daphnia) and the level of genetic variation for virulence for one (myxomatosis). We discuss the need for better data on tradeoff curves and genetic variance in order to evaluate the plausibility of various scenarios of virulence evolution.

  16. Combining slope stability and groundwater flow models to assess stratovolcano collapse hazard

    Science.gov (United States)

    Ball, J. L.; Taron, J.; Reid, M. E.; Hurwitz, S.; Finn, C.; Bedrosian, P.

    2016-12-01

    Flank collapses are a well-documented hazard at volcanoes. Elevated pore-fluid pressures and hydrothermal alteration are invoked as potential causes for the instability in many of these collapses. Because pore pressure is linked to water saturation and permeability of volcanic deposits, hydrothermal alteration is often suggested as a means of creating low-permeability zones in volcanoes. Here, we seek to address the question: What alteration geometries will produce elevated pore pressures in a stratovolcano, and what are the effects of these elevated pressures on slope stability? We initially use a finite element groundwater flow model (a modified version of OpenGeoSys) to simulate `generic' stratovolcano geometries that produce elevated pore pressures. We then input these results into the USGS slope-stability code Scoops3D to investigate the effects of alteration and magmatic intrusion on potential flank failure. This approach integrates geophysical data about subsurface alteration, water saturation and rock mechanical properties with data about precipitation and heat influx at Cascade stratovolcanoes. Our simulations show that it is possible to maintain high-elevation water tables in stratovolcanoes given specific ranges of edifice permeability (ideally between 10-15 and 10-16 m2). Low-permeability layers (10-17 m2, representing altered pyroclastic deposits or altered breccias) in the volcanoes can localize saturated regions close to the surface, but they may actually reduce saturation, pore pressures, and water table levels in the core of the volcano. These conditions produce universally lower factor-of-safety (F) values than at an equivalent dry edifice with the same material properties (lower values of F indicate a higher likelihood of collapse). When magmatic intrusions into the base of the cone are added, near-surface pore pressures increase and F decreases exponentially with time ( 7-8% in the first year). However, while near-surface impermeable layers

  17. Assessment of polyelectrolyte coating stability under dynamic buffer conditions in CE.

    Science.gov (United States)

    Swords, Kyleen E; Bartline, Peter B; Roguski, Katherine M; Bashaw, Sarah A; Frederick, Kimberley A

    2011-09-01

    Dynamic buffer conditions are present in many electrophoretically driven separations. Polyelectrolyte multilayer coatings have been employed in CE because of their chemical and physical stability as well as their ease of application. The goal of this study is to measure the effect of dynamic changes in buffer pH on flow using a real-time method for measuring EOF. Polyelectrolyte multilayers (PEMs) were composed of pairs of strong or completely ionized polyelectrolytes including poly(diallyldimethylammonium) chloride and poly(styrene sulfonate) and weak or ionizable polyelectrolytes including poly(allylamine) and poly(methacrylic acid). Polyelectrolyte multilayers of varying thicknesses (3, 4, 7, 8, 15, or 16 layers) were also studied. While the magnitude of the EOF was monitored every 2 s, the buffer pH was exchanged from a relatively basic pH (7.1) to increasingly acidic pHs (6.6, 6.1, 5.5, and 5.1). Strong polyelectrolytes responded minimally to changes in buffer pH (10%) and sometimes irreversible changes were measured with weak polyelectrolytes. Thicker coatings resulted in a similar magnitude of response but were more likely to degrade in response to buffer pH changes. The most stable coatings were formed from thinner layers of strong polyelectrolytes. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Assessing the Stability and Robustness of Semantic Web Services Recommendation Algorithms Under Profile Injection Attacks

    Directory of Open Access Journals (Sweden)

    GRANDIN, P. H.

    2014-06-01

    Full Text Available Recommendation systems based on collaborative filtering are open by nature, what makes them vulnerable to profile injection attacks that insert biased evaluations in the system database in order to manipulate recommendations. In this paper we evaluate the stability and robustness of collaborative filtering algorithms applied to semantic web services recommendation when submitted to random and segment profile injection attacks. We evaluated four algorithms: (1 IMEAN, that makes predictions using the average of the evaluations received by the target item; (2 UMEAN, that makes predictions using the average of the evaluation made by the target user; (3 an algorithm based on the k-nearest neighbor (k-NN method and (4, an algorithm based on the k-means clustering method.The experiments showed that the UMEAN algorithm is not affected by the attacks and that IMEAN is the most vulnerable of all algorithms tested. Nevertheless, both UMEAN and IMEAN have little practical application due to the low precision of their predictions. Among the algorithms with intermediate tolerance to attacks but with good prediction performance, the algorithm based on k-nn proved to be more robust and stable than the algorithm based on k-means.

  19. Direct labelling of monoclonal antibodies with 99Tcm. Assessment of labelling, stability, immunoreactivity and biodistribution

    International Nuclear Information System (INIS)

    Janoki, G.A.

    1998-01-01

    Reduction of disulfide bonds to sulfhydryl groups for direct radiolabelling of monoclonal antibodies for immunoscintigraphic application continues to be of significant interest. Reducing agents that have been used are the following: stannous ion, 2-mercaptoethanol, dithiothreitol, dithioerythriol, and ascorbic acid. The radiolabelling of the reduced and purified antibody is performed via Sn 2+ reduction of pertechnetate in the presence of an excess of a low-affinity chelating ligand. In a recent work the 2-mercaptoethanol (2-ME) reduction based method was studied by using different analytical and biological techniques. Human IgG (Sandoglobulin), anti-CEA MoAb (ior-1), and anti-granulocyte MoAb (MAK 47), were reduced with 2-ME at two different molar ratios. To determine the amount of contaminating mercaptoethanol which may have survived the gel-filtration step 14 C-ME was used. The number of the free endogenous sulfhydryl groups generated by reduction was determined by Ellman's reagent; absorbance was measured at 412 nm. Within the quality assurance procedure of the 3 freeze dried kits the labelling efficiency, stability, pH, sterility, apyrogenicity, vial yield, syringe retention, filterable activity, free SH determination and animal distribution were studied again. After receiving permission from local ethics committee pilot human studies were initiated. Study protocols were also approved

  20. Impact assessment of intermediate soil cover on landfill stabilization by characterizing landfilled municipal solid waste.

    Science.gov (United States)

    Qi, Guangxia; Yue, Dongbei; Liu, Jianguo; Li, Rui; Shi, Xiaochong; He, Liang; Guo, Jingting; Miao, Haomei; Nie, Yongfeng

    2013-10-15

    Waste samples at different depths of a covered municipal solid waste (MSW) landfill in Beijing, China, were excavated and characterized to investigate the impact of intermediate soil cover on waste stabilization. A comparatively high amount of unstable organic matter with 83.3 g kg(-1) dry weight (dw) total organic carbon was detected in the 6-year-old MSW, where toxic inorganic elements containing As, Cd, Cr, Cu, Mn, Ni, Pb, and Zn of 10.1, 0.98, 85.49, 259.7, 530.4, 30.5, 84.0, and 981.7 mg kg(-1) dw, respectively, largely accumulated because of the barrier effect of intermediate soil cover. This accumulation resulted in decreased microbial activities. The intermediate soil cover also caused significant reduction in moisture in MSW under the soil layer, which was as low as 25.9%, and led to inefficient biodegradation of 8- and 10-year-old MSW. Therefore, intermediate soil cover with low permeability seems to act as a barrier that divides a landfill into two landfill cells with different degradation processes by restraining water flow and hazardous matter. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Wide-Area Assessment of Aperiodic Small Signal Rotor Angle Stability in Real-Time

    DEFF Research Database (Denmark)

    Jóhannsson, Hjörtur; Nielsen, Arne Hejde; Østergaard, Jacob

    2014-01-01

    in rotor angle and a loss of synchronism, referred to as aperiodic small signal instability. The paper provides the theoretical background of the method and an analytical assessment criterion. Furthermore, a mathematical mapping of the generators' operating points that enables informative visualization...

  2. Four RNA families with functional transient structures.

    Science.gov (United States)

    Zhu, Jing Yun A; Meyer, Irmtraud M

    2015-01-01

    Protein-coding and non-coding RNA transcripts perform a wide variety of cellular functions in diverse organisms. Several of their functional roles are expressed and modulated via RNA structure. A given transcript, however, can have more than a single functional RNA structure throughout its life, a fact which has been previously overlooked. Transient RNA structures, for example, are only present during specific time intervals and cellular conditions. We here introduce four RNA families with transient RNA structures that play distinct and diverse functional roles. Moreover, we show that these transient RNA structures are structurally well-defined and evolutionarily conserved. Since Rfam annotates one structure for each family, there is either no annotation for these transient structures or no such family. Thus, our alignments either significantly update and extend the existing Rfam families or introduce a new RNA family to Rfam. For each of the four RNA families, we compile a multiple-sequence alignment based on experimentally verified transient and dominant (dominant in terms of either the thermodynamic stability and/or attention received so far) RNA secondary structures using a combination of automated search via covariance model and manual curation. The first alignment is the Trp operon leader which regulates the operon transcription in response to tryptophan abundance through alternative structures. The second alignment is the HDV ribozyme which we extend to the 5' flanking sequence. This flanking sequence is involved in the regulation of the transcript's self-cleavage activity. The third alignment is the 5' UTR of the maturation protein from Levivirus which contains a transient structure that temporarily postpones the formation of the final inhibitory structure to allow translation of maturation protein. The fourth and last alignment is the SAM riboswitch which regulates the downstream gene expression by assuming alternative structures upon binding of SAM. All

  3. Transient cognitive dynamics, metastability, and decision making.

    Directory of Open Access Journals (Sweden)

    Mikhail I Rabinovich

    2008-05-01

    Full Text Available The idea that cognitive activity can be understood using nonlinear dynamics has been intensively discussed at length for the last 15 years. One of the popular points of view is that metastable states play a key role in the execution of cognitive functions. Experimental and modeling studies suggest that most of these functions are the result of transient activity of large-scale brain networks in the presence of noise. Such transients may consist of a sequential switching between different metastable cognitive states. The main problem faced when using dynamical theory to describe transient cognitive processes is the fundamental contradiction between reproducibility and flexibility of transient behavior. In this paper, we propose a theoretical description of transient cognitive dynamics based on the interaction of functionally dependent metastable cognitive states. The mathematical image of such transient activity is a stable heteroclinic channel, i.e., a set of trajectories in the vicinity of a heteroclinic skeleton that consists of saddles and unstable separatrices that connect their surroundings. We suggest a basic mathematical model, a strongly dissipative dynamical system, and formulate the conditions for the robustness and reproducibility of cognitive transients that satisfy the competing requirements for stability and flexibility. Based on this approach, we describe here an effective solution for the problem of sequential decision making, represented as a fixed time game: a player takes sequential actions in a changing noisy environment so as to maximize a cumulative reward. As we predict and verify in computer simulations, noise plays an important role in optimizing the gain.

  4. Assessing the stability of polio eradication after the withdrawal of oral polio vaccine

    Science.gov (United States)

    Selinger, Christian; McCarthy, Kevin A.; Eckhoff, Philip A.; Chabot-Couture, Guillaume

    2018-01-01

    immunity will be required to ensure the stability of polio eradication. PMID:29702638

  5. Assessing the stability of polio eradication after the withdrawal of oral polio vaccine.

    Directory of Open Access Journals (Sweden)

    Michael Famulare

    2018-04-01

    population immunity will be required to ensure the stability of polio eradication.

  6. Assessing the physical-chemical properties and stability of dapivirine-loaded polymeric nanoparticles.

    Science.gov (United States)

    das Neves, José; Amiji, Mansoor; Bahia, Maria Fernanda; Sarmento, Bruno

    2013-11-18

    Nanocarriers may provide interesting delivery platforms for microbicide drugs and their characterization should be addressed early in development. Differently surface-engineered dapivirine-loaded, poly(epsilon-caprolactone) (PCL)-based nanoparticles (NPs) were obtained by nanoprecipitation using polyethylene oxide (PEO), sodium lauryl sulfate (SLS), or cetyltrimethylammonium bromide (CTAB) as surface modifiers. Physical-chemical properties of NP aqueous dispersions were evaluated upon storage at -20-40 °C for one year. NPs presented 170-200 nm in diameter, roundish-shape, low polydispersity index (≤0.18), and high drug association efficiency (≥97%) and loading (≥12.7%). NPs differed in zeta potential, depending on surface modifier (PEO: -27.9 mV; SLS: -54.7 mV; CTAB: +42.4 mV). No interactions among formulation components were detected by differential scanning calorimetry (DSC) and Fourier transform infrared spectroscopy (FTIR), except for SLS-PCL NPs. Colloidal properties of NPs were lost at -20 °C storage. Negatively charged NPs were stable up to one year at 5-40°C; as for CTAB-PCL NPs, particle aggregation was observed from 30 to 90 days of storage depending on temperature. Colloidal instability affected the in vitro drug release of CTAB-PCL NPs after 360 days. In any case, no degradation of dapivirine was apparent. Overall, PEO-PCL and SLS-PCL NPs presented suitable properties as nanocarriers for dapivirine. Conversely, CTAB-PCL NPs require additional strategies in order to increase stability. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. A microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks

    KAUST Repository

    Lautenschlä ger, Karin; Hwang, Chiachi; Liu, Wentso; Boon, Nico; Kö ster, Oliver; Vrouwenvelder, Johannes S.; Egli, Thomas; Hammes, Frederik A.

    2013-01-01

    and sensitive tool to assess and evaluate biological stability and microbial processes in drinking water distribution systems. © 2013 Elsevier Ltd.

  8. A microbiology-based multi-parametric approach towards assessing biological stability in drinking water distribution networks

    KAUST Repository

    Lautenschläger, Karin

    2013-06-01

    and sensitive tool to assess and evaluate biological stability and microbial processes in drinking water distribution systems. © 2013 Elsevier Ltd.

  9. Transient flow combustion

    Science.gov (United States)

    Tacina, R. R.

    1984-01-01

    Non-steady combustion problems can result from engine sources such as accelerations, decelerations, nozzle adjustments, augmentor ignition, and air perturbations into and out of the compressor. Also non-steady combustion can be generated internally from combustion instability or self-induced oscillations. A premixed-prevaporized combustor would be particularly sensitive to flow transients because of its susceptability to flashback-autoignition and blowout. An experimental program, the Transient Flow Combustion Study is in progress to study the effects of air and fuel flow transients on a premixed-prevaporized combustor. Preliminary tests performed at an inlet air temperature of 600 K, a reference velocity of 30 m/s, and a pressure of 700 kPa. The airflow was reduced to 1/3 of its original value in a 40 ms ramp before flashback occurred. Ramping the airflow up has shown that blowout is more sensitive than flashback to flow transients. Blowout occurred with a 25 percent increase in airflow (at a constant fuel-air ratio) in a 20 ms ramp. Combustion resonance was found at some conditions and may be important in determining the effects of flow transients.

  10. First principles, thermal stability and thermodynamic assessment of the binary Ni-W system

    Energy Technology Data Exchange (ETDEWEB)

    Isomaeki, Iikka; Haemaelaeinen, Marko; Gasik, Michael [Aalto Univ., Espoo (Finland). School of Chemical Engineering; Braga, Maria H. [Porto Univ. (Portugal). CEMUC, Physics Engineering Dept.

    2017-12-15

    The Ni-W binary system was assessed using critically evaluated experimental data with assistance from first principles analysis and the CALPHAD method. The solution phases (liquid, fcc-A1 and bcc-A2) were modeled using the substitutional regular solution model. The recently discovered Ni{sub 8}W metastable phase was evaluated as Fe{sub 16}C{sub 2}- like martensite with three sublattices, and shown to be possibly stable according to first principles calculations. Ni{sub 8}W was also modeled as an interstitial compound, but the model is not good because the solubility of tungsten in nickel is very low, especially at low temperatures. There is no experimental evidence for such low solubility. The other binary compounds Ni{sub 4}W and Ni{sub 3}W were assessed as stoichiometric ones. Compared independent experimental and first principles data agree well with the calculated phase diagram using updated thermodynamic parameters.

  11. Theoretical stability assessment of uranyl phosphates and apatites: Selection of amendments for in situ remediation of uranium

    International Nuclear Information System (INIS)

    Raicevic, S.; Wright, J.V.; Veljkovic, V.; Conca, J.L.

    2006-01-01

    Addition of an amendment or reagent to soil/sediment is a technique that can decrease mobility and reduce bioavailability of uranium (U) and other heavy metals in the contaminated site. According to data from literature and results obtained in field studies, the general mineral class of apatites was selected as a most promising amendment for in situ immobilization/remediation of U. In this work we presented theoretical assessment of stability of U(VI) in four apatite systems (hydroxyapatite (HAP), North Carolina Apatite (NCA), Lisina Apatite (LA), and Apatite II) in order to determine an optimal apatite soil amendment which could be used for in situ remediation of uranium. In this analysis we used a theoretical criterion which is based on calculation of the ion-ion interaction potential, representing the main term of the cohesive energy of the matrix/pollutant system. The presented results of this analysis indicate (i) that the mechanism of immobilization of U by natural apatites depends on their chemical composition and (ii) that all analyzed apatites represent, from the point of view of stability, promising materials which could be used in field remediation of U-contaminated sites

  12. Stability assessment and operating parameter optimization on experimental results in very small plasma focus, using sensitivity analysis

    Science.gov (United States)

    Jafari, Hossein; Habibi, Morteza

    2018-04-01

    Regarding the importance of stability in small-scale plasma focus devices for producing the repeatable and strength pinching, a sensitivity analysis approach has been used for applicability in design parameters optimization of an actually very low energy device (84 nF, 48 nH, 8-9.5 kV, ∼2.7-3.7 J). To optimize the devices functional specification, four different coaxial electrode configurations have been studied, scanning an argon gas pressure range from 0.6 to 1.5 mbar via the charging voltage variation study from 8.3 to 9.3 kV. The strength and efficient pinching was observed for the tapered anode configuration, over an expanded operating pressure range of 0.6 to 1.5 mbar. The analysis results showed that the most sensitive of the pinch voltage was associated with 0.88 ± 0.8mbar argon gas pressure and 8.3-8.5 kV charging voltage, respectively, as the optimum operating parameters. From the viewpoint of stability assessment of the device, it was observed that the least variation in stable operation of the device was for a charging voltage range of 8.3 to 8.7 kV in an operating pressure range from 0.6 to 1.1 mbar.

  13. Screening and assessment of solidification/stabilization amendments suitable for soils of lead-acid battery contaminated site.

    Science.gov (United States)

    Zhang, Zhuo; Guo, Guanlin; Teng, Yanguo; Wang, Jinsheng; Rhee, Jae Seong; Wang, Sen; Li, Fasheng

    2015-05-15

    Lead exposure via ingestion of soil and dust generally occurs at lead-acid battery manufacturing and recycling sites. Screening solidification/stabilization (S/S) amendments suitable for lead contaminated soil in an abandoned lead-acid battery factory site was conducted based on its chemical forms and environmental risks. Twelve amendments were used to immobilize the Pb in soil and assess the solidification/stabilization efficiency by toxicity leaching tests. The results indicated that three amendments, KH₂PO₄ (KP), KH₂PO₄:oyster shell power=1:1 (by mass ratio; SPP), and KH₂PO₄:sintered magnesia=1:1 (by mass ratio; KPM) had higher remediation efficiencies that led to a 92% reduction in leachable Pb with the addition of 5% amendments, while the acid soluble fraction of Pb (AS-Pb) decreased by 41-46% and the residual fraction (RS-Pb) increased by 16-25%. The S/S costs of the three selected amendments KP, SPP, and KPM could be controlled to $22.3 per ton of soil when the Pb concentration in soil ranged from 2000 to 3000 mg/kg. The results of this study demonstrated that KP, SPP, and KPM can effectively decrease bioavailability of Pb. These findings could provide basis for decision-making of S/S remediation of lead-acid battery contaminated sites. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Assessment and Stability of Early Learning Abilities in Preterm and Full-Term Infants across the First Two Years of Life

    Science.gov (United States)

    Lobo, Michele A.; Galloway, James C.

    2013-01-01

    Infants born preterm have increased risk for learning disabilities yet we lack assessments to successfully detect these disabilities in early life. We followed 23 full-term and 29 preterm infants from birth through 24 months to assess for differences in and stability of learning abilities across time. Measures included the Bayley-III cognitive…

  15. Assessment of slope stability, Kemmerer Coal Company pit 1-U-D, Frontier, Wyoming

    Energy Technology Data Exchange (ETDEWEB)

    Visca, P J; Call, R D

    1978-01-01

    This paper presents the results of a study to generate probability of failure schedules for use in an economic optimization analysis. The main objectives of the study were assessment of the possible modes of instability, calculation of the attendant degree of instability for each mode, and final compilation of probability of failure schedules for use in the economic optimization programme. The University of Arizona provided the mine plan configurations from which slope geometries for analysis were determined. (Available from Micromedia Ltd., 144 Front Street West, Toronto, Ontario M5J 1G2, Canada. Quote Contract No. OSQ77-00036)

  16. A conceptual framework for an ecosystem services-based assessment of the so-called "emergency stabilization" measures following wildfire

    Science.gov (United States)

    Valente, Sandra; Prats, Sergio; Ribeiro, Cristina; Verheijen, Frank; Fleskens, Luuk; Keizer, Jacob

    2015-04-01

    Wildfires have become a major environmental concern in many Southern European countries over the past few decades. This includes Portugal, where, on average, some 100 000 ha of rural lands are affected by wildfire every year. While policies, laws, plans and public expenditure in Portugal continue to be largely directed towards fire combat and, arguably, to a lesser extent fire prevention, there has only recently been increasing attention for post-fire land management. For example following frequent and several large wildfires during the summer of 2010, so-called emergency stabilization measures were implemented in 16 different burnt areas in northern and central Portugal, using funds of the EU Rural Development Plan in Portugal (PRODER). The measures that were implemented included mulching (i.e. application of a protective layer of organic material), seeding and the construction of log barriers. However, the effectiveness of the implemented measures has not been monitored or otherwise assessed in a systematic manner. In fact, until very recently none of the post-fire emergency stabilization measures contemplated under PRODER seem to have been studied in an exhaustive manner in Portugal, whether under laboratory or field conditions. Prats et al. (2012, 2013, 2014) tested two of these measures by field trials, i.e. hydro-mulching and forest residue mulching. The authors found both measures to be highly effective in terms of reducing overland flow and especially erosion. It remains a challenge, however, to assess the effectiveness of these and other measures in a broader context, not only beyond overland flow and sediment losses but also beyond the spatio-temporal scale that are typical for such field trials (plots and the first two years after fire). This challenge will be addressed in the Portuguese case study of the RECARE project. Nonetheless, the present study wants to be a first attempt at an ecosystem services-based assessment of mulching as a post

  17. Transient elastography for liver fibrosis diagnosis

    DEFF Research Database (Denmark)

    Andersen, Ellen Sloth; Christensen, Peer Brehm; Weis, Nina

    2008-01-01

    Liver biopsy is considered the "golden standard" for assessment of hepatic fibrosis. However, the procedure has limitations because of inconvenience and rare but serious complications as bleeding. Furthermore, sampling errors are frequent, and interobserver variability often poses problems....... Recently, a modified ultrasound scanner (transient elastography) has been developed to assess fibrosis. The device measures liver elasticity, which correlates well with the degree of fibrosis. Studies have shown that transient elastography is more accurate in diagnosing cirrhosis than minor to moderate...... to be a valuable diagnostic procedure and follow-up of patients with chronic liver diseases....

  18. Transient elastography for liver fibrosis diagnosis

    DEFF Research Database (Denmark)

    Andersen, Ellen Sloth; Christensen, Peer Brehm; Weis, Nina

    2009-01-01

    Liver biopsy is considered the "golden standard" for assessment of hepatic fibrosis. However, the procedure has limitations because of inconvenience and rare but serious complications as bleeding. Furthermore, sampling errors are frequent, and interobserver variability often poses problems....... Recently, a modified ultrasound scanner (transient elastography) has been developed to assess fibrosis. The device measures liver elasticity, which correlates well with the degree of fibrosis. Studies have shown that transient elastography is more accurate in diagnosing cirrhosis than minor to moderate...... to be a valuable diagnostic procedure and follow-up of patients with chronic liver diseases....

  19. A Novel Index for Online Voltage Stability Assessment Based on Correlation Characteristic of Voltage Profiles

    Directory of Open Access Journals (Sweden)

    M. R. Aghamohammadi

    2011-06-01

    Full Text Available Abstract: Voltage instability is a major threat for security of power systems. Preserving voltage security margin at a certain limit is a vital requirement for today’s power systems. Assessment of voltage security margin is a challenging task demanding sophisticated indices. In this paper, for the purpose of on line voltage security assessment a new index based on the correlation characteristic of network voltage profile is proposed. Voltage profile comprising all bus voltages contains the effect of network structure, load-generation patterns and reactive power compensation on the system behaviour and voltage security margin. Therefore, the proposed index is capable to clearly reveal the effect of system characteristics and events on the voltage security margin. The most attractive feature for this index is its fast and easy calculation from synchronously measured voltage profile without any need to system modelling and simulation and without any dependency on network size. At any instant of system operation by merely measuring network voltage profile and no further simulation calculation this index could be evaluated with respect to a specific reference profile. The results show that the behaviour of this index with respect to the change in system security is independent of the selected reference profile. The simplicity and easy calculation make this index very suitable for on line application. The proposed approach has been demonstrated on IEEE 39 bus test system with promising results showing its effectiveness and applicability.

  20. Transient hardened power FETs

    International Nuclear Information System (INIS)

    Dawes, W.R. Jr.; Fischer, T.A.; Huang, C.C.C.; Meyer, W.J.; Smith, C.S.; Blanchard, R.A.; Fortier, T.J.

    1986-01-01

    N-channel power FETs offer significant advantages in power conditioning circuits. Similiarily to all MOS technologies, power FET devices are vulnerable to ionizing radiation, and are particularily susceptible to burn-out in high dose rate irradiations (>1E10 rads(Si)/sec.), which precludes their use in many military environments. This paper will summarize the physical mechanisms responsible for burn-out, and discuss various fabrication techniques designed to improve the transient hardness of power FETs. Power FET devices were fabricated with several of these techniques, and data will be presented which demonstrates that transient hardness levels in excess of 1E12 rads(Si)/sec. are easily achievable