WorldWideScience

Sample records for transient magnetic effects

  1. Numerical calculation of transient field effects in quenching superconducting magnets

    International Nuclear Information System (INIS)

    Schwerg, Juljan Nikolai

    2010-01-01

    The maximum obtainable magnetic induction of accelerator magnets, relying on normal conducting cables and iron poles, is limited to around 2 T because of ohmic losses and iron saturation. Using superconducting cables, and employing permeable materials merely to reduce the fringe field, this limit can be exceeded and fields of more than 10 T can be obtained. A quench denotes the sudden transition from the superconducting to the normal conducting state. The drastic increase in electrical resistivity causes ohmic heating. The dissipated heat yields a temperature rise in the coil and causes the quench to propagate. The resulting high voltages and excessive temperatures can result in an irreversible damage of the magnet - to the extend of a cable melt-down. The quench behavior of a magnet depends on numerous factors, e.g. the magnet design, the applied magnet protection measures, the external electrical network, electrical and thermal material properties, and induced eddy current losses. The analysis and optimization of the quench behavior is an integral part of the construction of any superconducting magnet. The dissertation is divided in three complementary parts, i.e. the thesis, the detailed treatment and the appendix. In the thesis the quench process in superconducting accelerator magnets is studied. At first, we give an overview over features of accelerator magnets and physical phenomena occurring during a quench. For all relevant effects numerical models are introduced and adapted. The different models are weakly coupled in the quench algorithm and solved by means of an adaptive time-stepping method. This allows to resolve the variation of material properties as well as time constants. The quench model is validated by means of measurement data from magnets of the Large Hadron Collider. In a second step, we show results of protection studies for future accelerator magnets. The thesis ends with a summary of the results and a critical outlook on aspects which could

  2. Numerical calculation of transient field effects in quenching superconducting magnets

    Energy Technology Data Exchange (ETDEWEB)

    Schwerg, Juljan Nikolai

    2010-07-01

    The maximum obtainable magnetic induction of accelerator magnets, relying on normal conducting cables and iron poles, is limited to around 2 T because of ohmic losses and iron saturation. Using superconducting cables, and employing permeable materials merely to reduce the fringe field, this limit can be exceeded and fields of more than 10 T can be obtained. A quench denotes the sudden transition from the superconducting to the normal conducting state. The drastic increase in electrical resistivity causes ohmic heating. The dissipated heat yields a temperature rise in the coil and causes the quench to propagate. The resulting high voltages and excessive temperatures can result in an irreversible damage of the magnet - to the extend of a cable melt-down. The quench behavior of a magnet depends on numerous factors, e.g. the magnet design, the applied magnet protection measures, the external electrical network, electrical and thermal material properties, and induced eddy current losses. The analysis and optimization of the quench behavior is an integral part of the construction of any superconducting magnet. The dissertation is divided in three complementary parts, i.e. the thesis, the detailed treatment and the appendix. In the thesis the quench process in superconducting accelerator magnets is studied. At first, we give an overview over features of accelerator magnets and physical phenomena occurring during a quench. For all relevant effects numerical models are introduced and adapted. The different models are weakly coupled in the quench algorithm and solved by means of an adaptive time-stepping method. This allows to resolve the variation of material properties as well as time constants. The quench model is validated by means of measurement data from magnets of the Large Hadron Collider. In a second step, we show results of protection studies for future accelerator magnets. The thesis ends with a summary of the results and a critical outlook on aspects which could

  3. Numerical calculation of transient field effects in quenching superconducting magnets

    CERN Document Server

    Schwerg, Nikolai; Russenschuck, Stephan

    2009-01-01

    The maximum obtainable magnetic induction of accelerator magnets, relying on normal conducting cables and iron poles, is limited to around 2 T because of ohmic losses and iron saturation. Using superconducting cables, and employing permeable materials merely to reduce the fringe field, this limit can be exceeded and fields of more than 10 T can be obtained. A quench denotes the sudden transition from the superconducting to the normal conducting state. The drastic increase in electrical resistivity causes ohmic heating. The dissipated heat yields a temperature rise in the coil and causes the quench to propagate. The resulting high voltages and excessive temperatures can result in an irreversible damage of the magnet - to the extend of a cable melt-down. The quench behavior of a magnet depends on numerous factors, e.g. the magnet design, the applied magnet protection measures, the external electrical network, electrical and thermal material properties, and induced eddy current losses. The analysis and optimizat...

  4. Transient anisotropic magnetic field calculation

    International Nuclear Information System (INIS)

    Jesenik, Marko; Gorican, Viktor; Trlep, Mladen; Hamler, Anton; Stumberger, Bojan

    2006-01-01

    For anisotropic magnetic material, nonlinear magnetic characteristics of the material are described with magnetization curves for different magnetization directions. The paper presents transient finite element calculation of the magnetic field in the anisotropic magnetic material based on the measured magnetization curves for different magnetization directions. For the verification of the calculation method some results of the calculation are compared with the measurement

  5. Magnetic transients in flares

    International Nuclear Information System (INIS)

    Zirin, H.; Tanaka, K.

    1981-01-01

    We present data on magnetic transients (mgtr's) observed in flares on 1980 July 1 and 5 with Big Bear videomagnetograph (VMG). The 1980 July 1 event was a white light flare in which a strong bipolar mgtr was observed, and a definite change in the sunspots occurred at the time of the flare. In the 1980 July 5 flare, a mgtr was observed in only one polarity, and, although no sunspot changes occurred simultaneous with the flare, major spot changes occurred in a period of hours

  6. Effect of transient annealing on patterned CoFeB-based magnetic tunnel junctions

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kuo-Ming; Huang, Chao-Hsien; Lin, Shiao-Chi; Wu, Jong-Ching [Department of Physics and Taiwan SPIN Research Center, National Changhua University of Education, Changhua 50007 (China); Kao, Ming-Jer; Tsai, Ming-Jinn [Industrial Technology Research Institute, Hsinchu 31040 (China); Horng, Lance

    2007-12-15

    In this study, the transient annealing effect on the switching behavior of microstructured Co{sub 60}Fe{sub 20}B{sub 20}-based magnetic tunnel junctions has been studied through magnetoresistance measurements (R-H loop). Elliptical shape of devices with long/short axis of 4/2 micrometers was patterned out of sheet film stack of: Ta(20)/PtMn(15)/CoFeB(3)/Al(0.7)-oxide/CoFeB(2)/Ru(8)/Ta(40) (thickness unit in nanometers) after a conventional long time field cooling annealing. The transient annealing was then executed by sample loading into a furnace with pre-set temperatures ranging from 100 to 400 C for only 5 minutes in the absence of any external magnetic field. The vortex-like reverse of free layer in as-etched MTJ evidently changes to single-domain-like reverser after 200{proportional_to}250 C transient annealing. The magnetoresistance was found to increase with increasing annealing temperatures up to 265 C and then slowly decrease at higher annealing temperatures. The transient thermal annealing creates obvious efforts to repair magnetic properties of MTJ cell befor 265 C annealing and results in less damage at temperature of 350 C and 400 C. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Effect of transient annealing on patterned CoFeB-based magnetic tunnel junctions

    International Nuclear Information System (INIS)

    Wu, Kuo-Ming; Huang, Chao-Hsien; Lin, Shiao-Chi; Wu, Jong-Ching; Kao, Ming-Jer; Tsai, Ming-Jinn; Horng, Lance

    2007-01-01

    In this study, the transient annealing effect on the switching behavior of microstructured Co 60 Fe 20 B 20 -based magnetic tunnel junctions has been studied through magnetoresistance measurements (R-H loop). Elliptical shape of devices with long/short axis of 4/2 micrometers was patterned out of sheet film stack of: Ta(20)/PtMn(15)/CoFeB(3)/Al(0.7)-oxide/CoFeB(2)/Ru(8)/Ta(40) (thickness unit in nanometers) after a conventional long time field cooling annealing. The transient annealing was then executed by sample loading into a furnace with pre-set temperatures ranging from 100 to 400 C for only 5 minutes in the absence of any external magnetic field. The vortex-like reverse of free layer in as-etched MTJ evidently changes to single-domain-like reverser after 200∝250 C transient annealing. The magnetoresistance was found to increase with increasing annealing temperatures up to 265 C and then slowly decrease at higher annealing temperatures. The transient thermal annealing creates obvious efforts to repair magnetic properties of MTJ cell befor 265 C annealing and results in less damage at temperature of 350 C and 400 C. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Magnetic state dependent transient lateral photovoltaic effect in patterned ferromagnetic metal-oxide-semiconductor films

    Directory of Open Access Journals (Sweden)

    Isidoro Martinez

    2015-11-01

    Full Text Available We investigate the influence of an external magnetic field on the magnitude and dephasing of the transient lateral photovoltaic effect (T-LPE in lithographically patterned Co lines of widths of a few microns grown over naturally passivated p-type Si(100. The T-LPE peak-to-peak magnitude and dephasing, measured by lock-in or through the characteristic time of laser OFF exponential relaxation, exhibit a notable influence of the magnetization direction of the ferromagnetic overlayer. We show experimentally and by numerical simulations that the T-LPE magnitude is determined by the Co anisotropic magnetoresistance. On the other hand, the magnetic field dependence of the dephasing could be described by the influence of the Lorentz force acting perpendiculary to both the Co magnetization and the photocarrier drift directions. Our findings could stimulate the development of fast position sensitive detectors with magnetically tuned magnitude and phase responses.

  9. Application of Java Technology to Simulation of Transient Effects in Accelerator Magnets

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Superconducting magnets are one of the key building blocks of modern high-energy particle accelerators. Operating at extremely low temperatures (1.9 K), superconducting magnets produce high magnetic field needed to control the trajectory of beams travelling at nearly the speed of light. With high performance comes considerable complexity represented by several coupled physical domains characterized by multi-rate and multi-scale behaviour. The full exploitation of the LHC, as well as the design of its upgrades and future accelerators calls for more accurate simulations. With such a long-term vision in mind, the STEAM (Simulation of Transient Effects in Accelerator Magnets) project has been establish and is based on two pillars: (i) models developed with optimised solvers for particular sub-problems, (ii) coupling interfaces allowing to exchange information between the models. In order to tackle these challenges and develop a maintainable and extendable simulation framework, a team of developers implemented a ...

  10. Transient magnetic field changes in flares

    International Nuclear Information System (INIS)

    Patterson, A.; Zirin, H.

    1981-01-01

    Magnetic changes have been detected with the videomagnetograph (VMG) at Big Bear during two large flares on 1979 November 5. Two kinds of changes were detected in both flares: a decrease in satellite field strength near the locus of the flare and the appearance of strong transient fields during the peak of the flare. We explain why we believe that the observed effects are real and not instrumental and discuss their significance for flare studies

  11. Effect of coupling currents on the dynamic inductance during fast transient in superconducting magnets

    Directory of Open Access Journals (Sweden)

    V. Marinozzi

    2015-03-01

    Full Text Available We present electromagnetic models aiming to calculate the variation of the inductance in a magnet due to dynamic effects such as the variation of magnetization or the coupling with eddy currents. The models are studied with special regard to the calculation of the inductance in superconducting magnets which are affected by interfilament coupling currents. The developed models have been compared with experimental data coming from tests of prototype Nb_{3}Sn magnets designed for the new generation of accelerators. This work is relevant for the quench protection study of superconducting magnets: quench is an unwanted event, when part of the magnet becomes resistive; in these cases, the current should be discharged as fast as possible, in order to maintain the resistive zone temperature under a safe limit. The magnet inductance is therefore a relevant term for the description of the current discharge, especially for the high-field new generation superconducting magnets for accelerators, and this work shows how to calculate the correct value during rapid current changes, providing a mean for simulations of the reached temperature.

  12. Globally coherent short duration magnetic field transients and their effect on ground based gravitational-wave detectors

    International Nuclear Information System (INIS)

    Kowalska-Leszczynska, Izabela; Bulik, Tomasz; Bizouard, Marie-Anne; Robinet, Florent; Christensen, Nelson; Rohde, Maximilian; Coughlin, Michael; Gołkowski, Mark; Kubisz, Jerzy; Kulak, Andrzej; Mlynarczyk, Janusz

    2017-01-01

    It has been recognized that the magnetic fields from the Schumann resonances could affect the search for a stochastic gravitational-wave background by LIGO and Virgo. Presented here are the observations of short duration magnetic field transients that are coincident in the magnetometers at the LIGO and Virgo sites. Data from low-noise magnetometers in Poland and Colorado, USA, are also used and show short duration magnetic transients of global extent. We measure at least 2.3 coincident (between Poland and Colorado) magnetic transient events per day where one of the pulses exceeds 200 pT. Given the recently measured values of the magnetic coupling to differential arm motion for Advanced LIGO, there would be a few events per day that would appear simultaneously at the gravitational-wave detector sites and could move the test masses of order 10 −18 m. We confirm that in the advanced detector era short duration transient gravitational-wave searches must account for correlated magnetic field noise in the global detector network. (paper)

  13. Response of dairy cattle to transient voltages and magnetic fields

    International Nuclear Information System (INIS)

    Reinemann, D.J.; Laughlin, N.K.; Stetson, L.E.

    1995-01-01

    Stray voltages in dairy facilities have been studied since the 1970's. Previous research using steady-state ac and dc voltages has defined cow-contact voltage levels which may cause behavior and associated production problems. This research was designed to address concerns over possible effects of transient voltages and magnetic fields on dairy cows. Dairy cows response to transient voltages and magnetic fields was measured. The waveforms of the transient voltages applied were: 5 cycles of 60-Hz ac with a total pulse time of 83 ms, 1 cycle of 60-Hz ac with a total pulse time of 16 ms, and 1 cycle of an ac square wave (spiking positive and negative) of 2-ms duration. Alternating magnetic fields were produced by passing 60-Hz ac fundamental frequency with 2nd and 3rd harmonic and random noise components in metal structures around the cows. The maximum magnetic field associated with this current flow was in excess of 4 G. A wide range of sensitivity to transient voltages was observed among cows. Response levels from 24 cows to each transient exposure were normally distributed. No responses to magnetic fields were observed

  14. Protective effects of repetitive transcranial magnetic stimulation in a rat model of transient cerebral ischaemia: a microPET study

    International Nuclear Information System (INIS)

    Gao, Feng; Wang, Shuang; Guo, Yi; Lou, Min; Wu, Jimin; Ding, Meiping; Wang, Jing; Zhang, Hong; Tian, Mei

    2010-01-01

    Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive method to excite neurons in the brain. However, the underlying mechanism of its therapeutic effects in stroke remains unclear. The aim of this study was to investigate the neuroprotective effect of high-frequency rTMS in a rat model of transient cerebral ischaemia using positron emission tomography (PET). Sprague-Dawley rats (n=30) were anaesthetized with chloral hydrate and subjected to 90 min of intraluminal middle cerebral artery occlusion (MCAO) with subsequent reperfusion in three groups: control (n=10), rTMS (n=10), or sham-rTMS groups (n=10). In the rTMS group, rTMS was given 1 h after ischaemia and every 24 h for 7 days after MCAO. In all three groups, small-animal PET (microPET) imaging with 18 F-FDG was used to evaluate brain glucose metabolism. Apoptotic molecules were measured in the infarct margin using immunohistochemical staining. The neurological scores of the rats in the rTMS group were higher than in those of the control group over the whole 7-day observation period. The total, cortical and striatal infarct volumes were significantly less in the rTMS group than in the control group, as measured by 2,3,5-triphenyltetrazolium chloride staining. 18 F-FDG microPET images showed significantly higher standardized uptake values in the cortex and striatum in the rTMS group than in the control group in the affected hemisphere. The number of cells positive for caspase-3 was significantly lower in the rTMS group than in the control group, while the Bcl-2/Bax ratio was significantly higher in the rTMS group than in the control group. rTMS therapy increased glucose metabolism and inhibited apoptosis in the ischaemic hemisphere. 18 F-FDG PET could be used to monitor rTMS therapy in transient cerebral ischaemia in animal studies and in future clinical trials. (orig.)

  15. Protective effects of repetitive transcranial magnetic stimulation in a rat model of transient cerebral ischaemia: a microPET study

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Feng [Second Affiliated Hospital of Zhejiang University School of Medicine, Department of Nuclear Medicine, Hangzhou, Zhejiang (China); Second Affiliated Hospital of Zhejiang University School of Medicine, Department of Neurology, Hangzhou, Zhejiang (China); Zhejiang University Medical PET Center, Hangzhou, Zhejiang (China); Institute of Nuclear Medicine and Molecular Imaging of Zhejiang University, Hangzhou, Zhejiang (China); Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, Zhejiang (China); Wang, Shuang; Guo, Yi; Lou, Min; Wu, Jimin; Ding, Meiping [Second Affiliated Hospital of Zhejiang University School of Medicine, Department of Neurology, Hangzhou, Zhejiang (China); Wang, Jing; Zhang, Hong [Second Affiliated Hospital of Zhejiang University School of Medicine, Department of Nuclear Medicine, Hangzhou, Zhejiang (China); Zhejiang University Medical PET Center, Hangzhou, Zhejiang (China); Institute of Nuclear Medicine and Molecular Imaging of Zhejiang University, Hangzhou, Zhejiang (China); Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, Zhejiang (China); Tian, Mei [The University of Texas M.D. Anderson Cancer Center, Department of Experimental Diagnostic Imaging, Houston, TX (United States)

    2010-05-15

    Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive method to excite neurons in the brain. However, the underlying mechanism of its therapeutic effects in stroke remains unclear. The aim of this study was to investigate the neuroprotective effect of high-frequency rTMS in a rat model of transient cerebral ischaemia using positron emission tomography (PET). Sprague-Dawley rats (n=30) were anaesthetized with chloral hydrate and subjected to 90 min of intraluminal middle cerebral artery occlusion (MCAO) with subsequent reperfusion in three groups: control (n=10), rTMS (n=10), or sham-rTMS groups (n=10). In the rTMS group, rTMS was given 1 h after ischaemia and every 24 h for 7 days after MCAO. In all three groups, small-animal PET (microPET) imaging with {sup 18}F-FDG was used to evaluate brain glucose metabolism. Apoptotic molecules were measured in the infarct margin using immunohistochemical staining. The neurological scores of the rats in the rTMS group were higher than in those of the control group over the whole 7-day observation period. The total, cortical and striatal infarct volumes were significantly less in the rTMS group than in the control group, as measured by 2,3,5-triphenyltetrazolium chloride staining. {sup 18}F-FDG microPET images showed significantly higher standardized uptake values in the cortex and striatum in the rTMS group than in the control group in the affected hemisphere. The number of cells positive for caspase-3 was significantly lower in the rTMS group than in the control group, while the Bcl-2/Bax ratio was significantly higher in the rTMS group than in the control group. rTMS therapy increased glucose metabolism and inhibited apoptosis in the ischaemic hemisphere. {sup 18}F-FDG PET could be used to monitor rTMS therapy in transient cerebral ischaemia in animal studies and in future clinical trials. (orig.)

  16. Generation of intense transient magnetic fields

    International Nuclear Information System (INIS)

    Benjamin, R.F.

    1983-01-01

    In a laser system, the return current of a laser generated plasma is conducted near a target to subject that target to a magnetic field. The target may be either a small non-fusion object for testing under the magnetic field or a laser-fusion pellet. In the laser-fusion embodiment, the laser-fusion pellet is irradiated during the return current flow and the intense transient magnetic field is used to control the hot electrons thereof to hinder them from striking and heating the core of the irradiated laser-fusion pellet. An emitter, e.g. a microballoon of glass, metal or plastics, is subjected to a laser pulse to generate the plasma from which the return current flows into a wire cage or a coil and then to earth. (author)

  17. Transient Analysis of a Magnetic Heat Pump

    Science.gov (United States)

    Schroeder, E. A.

    1985-01-01

    An experimental heat pump that uses a rare earth element as the refrigerant is modeled using NASTRAN. The refrigerant is a ferromagnetic metal whose temperature rises when a magnetic field is applied and falls when the magnetic field is removed. The heat pump is used as a refrigerator to remove heat from a reservoir and discharge it through a heat exchanger. In the NASTRAN model the components modeled are represented by one-dimensional ROD elements. Heat flow in the solids and fluid are analyzed. The problem is mildly nonlinear since the heat capacity of the refrigerant is temperature-dependent. One simulation run consists of a series of transient analyses, each representing one stroke of the heat pump. An auxiliary program was written that uses the results of one NASTRAN analysis to generate data for the next NASTRAN analysis.

  18. Investigation of transient electrical, magnetic, and mechanical phenomena in large superconducting magnet coils

    International Nuclear Information System (INIS)

    Sihler, C.

    1996-07-01

    The progress in the field of technology for superconducting magnets led to the necessity of transferring existing calculation methods from electrical power engineering, modifying these tools to satisfy the boundary conditions for superconducting magnets, and also developing new calculation methods for special purposes. In this work suitable calculation methods are elaborated. Their validity and applicability is demonstrated in employing these scientific engineering tools to actual developments of the Forschungszentrum Karlsruhe. In detail this work deals with: 1. calculating eddy current and force densities in the conducting environment of a superconducting magnet or magnet system. 2. the effects of eddy current forces in experimental engineering; 3. transient effects of electrical surges acting on new coil designs; and 4. the electrical and magnetic properties of superconducting cables. Especially, the magnetic properties can lead to an inhomogeneous current distribution in the cable and, thus, to a considerable reduction of the current carrying capacity of the whole magnet. These investigations demonstrate that a detailed analysis of electrodynamic phenomena is indispensable in order to find the optimum technical way to make use of the physical potential of superconductivity. (orig./MM) [de

  19. ELF Magnetic Fields, Transients and TWA Metrics (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Kavet, R

    1999-07-01

    Residential measurements of ambient power frequency magnetic fields may serve as surrogates for personal exposures. There are few data available, however, to determine how far back in time this surrogacy holds. A limited amount of research on residential transients suggests that, all other factors being equivalent, larger transients may propagate within VHCC neighbourhoods than within LCC neighbourhoods. However, the presence of a conductive residential ground pathway also appears to be a potentially important factor associated with residential transient activity. The use of the TWA metric was prompted by the need for an exposure score simple enough to summarise an individual's exposure over a prior interval, yet specific to the agent of concern, namely the power frequency magnetic field. To the extent that the TWA exposure is associated with health outcomes in the absence of bias, including confounding, the TWA metric is important. (author)

  20. ELF Magnetic Fields, Transients and TWA Metrics (invited paper)

    International Nuclear Information System (INIS)

    Kavet, R.

    1999-01-01

    Residential measurements of ambient power frequency magnetic fields may serve as surrogates for personal exposures. There are few data available, however, to determine how far back in time this surrogacy holds. A limited amount of research on residential transients suggests that, all other factors being equivalent, larger transients may propagate within VHCC neighbourhoods than within LCC neighbourhoods. However, the presence of a conductive residential ground pathway also appears to be a potentially important factor associated with residential transient activity. The use of the TWA metric was prompted by the need for an exposure score simple enough to summarise an individual's exposure over a prior interval, yet specific to the agent of concern, namely the power frequency magnetic field. To the extent that the TWA exposure is associated with health outcomes in the absence of bias, including confounding, the TWA metric is important. (author)

  1. Multiharmonic rf feedforward system for compensation of beam loading and periodic transient effects in magnetic-alloy cavities of a proton synchrotron

    Directory of Open Access Journals (Sweden)

    Fumihiko Tamura

    2013-05-01

    Full Text Available Beam loading compensation is a key for acceleration of a high intensity proton beam in the main ring (MR of the Japan Proton Accelerator Research Complex (J-PARC. Magnetic alloy loaded rf cavities with a Q value of 22 are used to achieve high accelerating voltages without a tuning bias loop. The cavity is driven by a single harmonic (h=9 rf signal while the cavity frequency response also covers the neighbor harmonics (h=8,10. Therefore the wake voltage induced by the high intensity beam consists of the three harmonics, h=8,9,10. The beam loading of neighbor harmonics is the source of periodic transient effects and a possible source of coupled bunch instabilities. In the article, we analyze the wake voltage induced by the high intensity beam. We employ the rf feedforward method to compensate the beam loading of these three harmonics (h=8,9,10. The full-digital multiharmonic feedforward system was developed for the MR. We describe the system architecture and the commissioning methodology of the feedforward patterns. The commissioning of the feedforward system has been performed by using high intensity beams with 1.0×10^{14} proteins per pulse. The impedance seen by the beam is successfully reduced and the longitudinal oscillations due to the beam loading are reduced. By the beam loading compensation, stable high power beam operation is achieved. We also report the reduction of the momentum loss during the debunching process for the slow extraction by the feedforward.

  2. Application of transient magnetic field to the measurement of nuclear magnetic moments

    International Nuclear Information System (INIS)

    Ribas, R.V.

    1987-01-01

    A review on: the mechanism for producing transient magnetic field; techniques for measuring nuclear gyromagnetic factor; and some examples of recent measurements using this technique is presented. (M.C.K.) [pt

  3. Magnetic field measurements using the transient internal probe (TIP)

    International Nuclear Information System (INIS)

    Galambos, J.P.; Bohnet, M.A.; Jarboe, T.R.; Mattick, A.T.

    1995-01-01

    Knowledge of the internal magnetic field profile in hot plasmas is fundamental to understanding the structure and behavior of the current profile. The transient internal probe (TIP) is a novel diagnostic designed to measure internal magnetic fields in hot plasmas. The diagnostic involves shooting a magneto-optic probe through the plasma at high velocities (greater than 2 km/s) using a two stage light gas gun. Local fields are obtained by illuminating the probe with an argon ion laser and measuring the amount of Faraday rotation in the reflected beam. Initial development of the diagnostic is complete. Results of magnetic field measurements conducted at 2 km/s will be presented. Helium muzzle gas introduction to the plasma chamber has been limited to less than 0.4 Torr-ell. Magnetic field resolution of 40 Gauss and spatial resolution of 5 mm have been achieved. System frequency response is 10 MHz

  4. Transient flows in rectangular MHD ducts under the influence of suddenly changing applied magnetic fields

    International Nuclear Information System (INIS)

    Kobayashi, Junichi

    1979-01-01

    The study on the transient flow characteristics in MHD ducts under orthogonal magnetic field is divided into handling two problems: the problem of changing pressure gradient in a uniform orthogonal magnetic field and the problem in which the orthogonal magnetic field itself changes with time. The former has been investigated by many persons, but the latter has not been investigated so often as the former because of its difficulty of handling. In addition, if it is intended to grasp properly the transient flow characteristics in actual MHD ducts, it will be also important that the effects of the electric conductivity of side walls and aspect ratio are clarified. In other words, this paper deals with the problem in which a uniform orthogonal magnetic field is suddenly applied in such manner as Heaviside's step function to or removed from the conductive fluids flowing in sufficiently long rectangular MHD ducts. First, the MHD fundamental equations are described, then they are normalized to give boundary conditions and initial conditions. Next, the transient flow and the derived magnetic field characteristics are numerically analyzed by the difference calculus, and thus the effects of conductor, insulated wall, aspect ratio, Hartmann number, magnetic Prandtl number and others on the above characteristics are clarified. (Wakatsuki, Y.)

  5. Transient finite element magnetic field calculation method in the anisotropic magnetic material based on the measured magnetization curves

    International Nuclear Information System (INIS)

    Jesenik, M.; Gorican, V.; Trlep, M.; Hamler, A.; Stumberger, B.

    2006-01-01

    A lot of magnetic materials are anisotropic. In the 3D finite element method calculation, anisotropy of the material is taken into account. Anisotropic magnetic material is described with magnetization curves for different magnetization directions. The 3D transient calculation of the rotational magnetic field in the sample of the round rotational single sheet tester with circular sample considering eddy currents is made and compared with the measurement to verify the correctness of the method and to analyze the magnetic field in the sample

  6. Development of transient internal probe (TIP) magnetic field diagnostic

    International Nuclear Information System (INIS)

    Galambos, J.P.; Bohnet, M.A.; Jarboe, T.R.; Mattick, A.T.

    1994-01-01

    The Transient Internal Probe (TIP) is designed to permit measurement of internal magnetic fields, in hot, high density plasmas. The concept consists of accelerating a probe to high velocities (2.2 Km/s) in order to minimize probe exposure time to plasma. Faraday rotation within the probe is used to measure the local magnetic field. An Argon laser illuminates the probe consisting of a Faraday-rotator material with a retro-reflector that returns the incident light to the detection system. Performance results of the light gas gun and optical detection system will be shown. To date, the gas gun has been extensively tested consistently achieving velocities between 2 and 3 km/s. The probe and detection scheme have been tested by dropping the probe through a static magnetic field. Magnetic field resolution of 20 gauss and spatial resolution of 5 mm has been achieved. System frequency response is 10Mhz. Work is currently being conducted to integrate the diagnostic system with laboratory plasma experiments. Specifically a gas interfaced system has been developed to prevent helium muzzle gas from entering the plasma chamber with the probe. Additionally the probe must be separated from the sabot which protects the probe during acceleration in the gas gun. Data will be presented showing the results of various separation techniques

  7. Strain and thermally induced magnetic dynamics and spin current in magnetic insulators subject to transient optical grating

    Science.gov (United States)

    Wang, Xi-Guang; Chotorlishvili, Levan; Berakdar, Jamal

    2017-07-01

    We analyze the magnetic dynamics and particularlythe spin current in an open-circuit ferromagnetic insulator irradiated by two intense, phase-locked laser pulses. The interference of the laser beams generates a transient optical grating and a transient spatio-temporal temperature distribution. Both effects lead to elastic and heat waves at the surface and into the bulk of the sample. The strain induced spin current as well as the thermally induced magnonic spin current are evaluated numerically on the basis of micromagnetic simulations using solutions of the heat equation. We observe that the thermo-elastically induced magnonic spin current propagates on a distance larger than the characteristic size of thermal profile, an effect useful for applications in remote detection of spin caloritronics phenomena. Our findings point out that exploiting strain adds a new twist to heat-assisted magnetic switching and spin-current generation for spintronic applications.

  8. THE EFFECTS OF TRANSIENTS ON PHOTOSPHERIC AND CHROMOSPHERIC POWER DISTRIBUTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Samanta, T.; Banerjee, D.; Pant, V. [Indian Institute of Astrophysics, Koramangala, Bangalore 560034 (India); Henriques, V. M. J.; Prasad, S. Krishna; Mathioudakis, M.; Jess, D., E-mail: tsamanta@iiap.res.in, E-mail: v.henriques@qub.ac.uk [Astrophysics Research Centre, School of Mathematics and Physics, Queen’s University Belfast, Belfast BT7 1NN (United Kingdom)

    2016-09-01

    We have observed a quiet-Sun region with the Swedish 1 m Solar Telescope equipped with the CRISP Imaging SpectroPolarimeter. High-resolution, high-cadence, H α line scanning images were taken to observe different layers of the solar atmosphere from the photosphere to upper chromosphere. We study the distribution of power in different period bands at different heights. Power maps of the upper photosphere and the lower chromosphere show suppressed power surrounding the magnetic-network elements, known as “magnetic shadows.” These also show enhanced power close to the photosphere, traditionally referred to as “power halos.” The interaction between acoustic waves and inclined magnetic fields is generally believed to be responsible for these two effects. In this study we explore whether small-scale transients can influence the distribution of power at different heights. We show that the presence of transients, like mottles, Rapid Blueshifted Excursions (RBEs), and Rapid Redshifted Excursions (RREs), can strongly influence the power maps. The short and finite lifetime of these events strongly affects all power maps, potentially influencing the observed power distribution. We show that Doppler-shifted transients like RBEs and RREs that occur ubiquitously can have a dominant effect on the formation of the power halos in the quiet Sun. For magnetic shadows, transients like mottles do not seem to have a significant effect on the power suppression around 3 minutes, and wave interaction may play a key role here. Our high-cadence observations reveal that flows, waves, and shocks manifest in the presence of magnetic fields to form a nonlinear magnetohydrodynamic system.

  9. Transient effects in friction fractal asperity creep

    CERN Document Server

    Goedecke, Andreas

    2013-01-01

    Transient friction effects determine the behavior of a wide class of mechatronic systems. Classic examples are squealing brakes, stiction in robotic arms, or stick-slip in linear drives. To properly design and understand mechatronic systems of this type, good quantitative models of transient friction effects are of primary interest. The theory developed in this book approaches this problem bottom-up, by deriving the behavior of macroscopic friction surfaces from the microscopic surface physics. The model is based on two assumptions: First, rough surfaces are inherently fractal, exhibiting roughness on a wide range of scales. Second, transient friction effects are caused by creep enlargement of the real area of contact between two bodies. This work demonstrates the results of extensive Finite Element analyses of the creep behavior of surface asperities, and proposes a generalized multi-scale area iteration for calculating the time-dependent real contact between two bodies. The toolset is then demonstrated both...

  10. CONNECTING FLARES AND TRANSIENT MASS-LOSS EVENTS IN MAGNETICALLY ACTIVE STARS

    Energy Technology Data Exchange (ETDEWEB)

    Osten, Rachel A. [Space Telescope Science Institute 3700 San Martin Drive, Baltimore, MD 21218 (United States); Wolk, Scott J., E-mail: osten@stsci.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge MA 02138 (United States)

    2015-08-10

    We explore the ramification of associating the energetics of extreme magnetic reconnection events with transient mass-loss in a stellar analogy with solar eruptive events. We establish energy partitions relative to the total bolometric radiated flare energy for different observed components of stellar flares and show that there is rough agreement for these values with solar flares. We apply an equipartition between the bolometric radiated flare energy and kinetic energy in an accompanying mass ejection, seen in solar eruptive events and expected from reconnection. This allows an integrated flare rate in a particular waveband to be used to estimate the amount of associated transient mass-loss. This approach is supported by a good correspondence between observational flare signatures on high flaring rate stars and the Sun, which suggests a common physical origin. If the frequent and extreme flares that young solar-like stars and low-mass stars experience are accompanied by transient mass-loss in the form of coronal mass ejections, then the cumulative effect of this mass-loss could be large. We find that for young solar-like stars and active M dwarfs, the total mass lost due to transient magnetic eruptions could have significant impacts on disk evolution, and thus planet formation, and also exoplanet habitability.

  11. Influence of resonant magnetic perturbations on transient heat load deposition and fast ion losses

    International Nuclear Information System (INIS)

    Rack, Michael Thomas

    2014-01-01

    Thermonuclear fusion is the energy conversion process which keeps the sun shining. For the last six decades, researchers have been investigating the physics involved in order to enable the usage of this energy supply on Earth. The most promising candidates for fusion power plants are based on magnetic confinement of plasma to provide the ideal conditions for efficient thermonuclear fusion in well controlled surroundings. One important aspect is the control of instabilities that occur in the edge region of the plasma and lead to an ejection of huge amounts of energy. Magnetic perturbation fields which are resonant in the plasma edge are found to modify the plasma favourably and reduce the impact of these instabilities. This dissertation focuses on the effects of resonant magnetic perturbation fields on the ejected energy as well as on the drawbacks of these perturbation fields. The transient energy ejection which is triggered by the instabilities causes extreme heat loads on the wall components in fusion devices. Therefore, it is crucial to understand how resonant magnetic perturbation fields affect the heat load deposition. Furthermore, the impact of resonant magnetic perturbation fields on the confinement of fast ions is an important aspect as fast ions are still required to be well confined in order to avoid additional wall loads and increase the fusion efficiency. Recent upgrades on the Joint European Torus allow for a detailed study of the heat load deposition profiles caused by transient events. Throughout this work, the new features are used for the study of the modifications of the transient heat load depositions that occur if resonant magnetic perturbation fields are applied. This leads to a further understanding of the processes involved during the plasma edge instabilities. Additionally, an alternative method using lower hybrid waves for applying resonant magnetic perturbations is investigated. Furthermore, a new diagnostic, capable of detecting fast ion

  12. Influence of resonant magnetic perturbations on transient heat load deposition and fast ion losses

    Energy Technology Data Exchange (ETDEWEB)

    Rack, Michael Thomas

    2014-07-11

    Thermonuclear fusion is the energy conversion process which keeps the sun shining. For the last six decades, researchers have been investigating the physics involved in order to enable the usage of this energy supply on Earth. The most promising candidates for fusion power plants are based on magnetic confinement of plasma to provide the ideal conditions for efficient thermonuclear fusion in well controlled surroundings. One important aspect is the control of instabilities that occur in the edge region of the plasma and lead to an ejection of huge amounts of energy. Magnetic perturbation fields which are resonant in the plasma edge are found to modify the plasma favourably and reduce the impact of these instabilities. This dissertation focuses on the effects of resonant magnetic perturbation fields on the ejected energy as well as on the drawbacks of these perturbation fields. The transient energy ejection which is triggered by the instabilities causes extreme heat loads on the wall components in fusion devices. Therefore, it is crucial to understand how resonant magnetic perturbation fields affect the heat load deposition. Furthermore, the impact of resonant magnetic perturbation fields on the confinement of fast ions is an important aspect as fast ions are still required to be well confined in order to avoid additional wall loads and increase the fusion efficiency. Recent upgrades on the Joint European Torus allow for a detailed study of the heat load deposition profiles caused by transient events. Throughout this work, the new features are used for the study of the modifications of the transient heat load depositions that occur if resonant magnetic perturbation fields are applied. This leads to a further understanding of the processes involved during the plasma edge instabilities. Additionally, an alternative method using lower hybrid waves for applying resonant magnetic perturbations is investigated. Furthermore, a new diagnostic, capable of detecting fast ion

  13. Ultrafast Control of Magnetism in Ferromagnetic Semiconductors via Photoexcited Transient Carriers

    Energy Technology Data Exchange (ETDEWEB)

    Cotoros, Ingrid A. [Univ. of California, Berkeley, CA (United States)

    2008-12-01

    The field of spintronics offers perspectives for seamless integration of coupled and inter-tunable electrical and magnetic properties in a single device. For integration of the spin degree of freedom with current electronic technology, new semiconductors are needed that show electrically-tunable magnetic properties at room temperature and above. Dilute magnetic semiconductors derived from III-V compounds, like GaMnAs and InMnAs, show coupled and tunable magnetic, transport, and optical properties, due to the fact that their ferromagnetism is hole-mediated. These unconventional materials are ideal systems for manipulating the magnetic order by changing the carrier polarization, population density, and energy band distribution of the complementary subsystem of holes. This is the main theme we cover in this thesis. In particular, we develop a unique setup by use of ultraviolet pump, near-infrared probe femtosecond laser pulses, that allows for magneto-optical Kerr effect (MOKE) spectroscopy experiments. We photo-excite transient carriers in our samples, and measure the induced transient magnetization dynamics. One set of experiments performed allowed us to observe for the first time enhancement of the ferromagnetic order in GaMnAs, on an ultrafast time scale of hundreds of picoseconds. The corresponding transient increase of Curie temperature (Tc, the temperature above which a ferromagnetic material loses its permanent magnetism) of about 1 K for our experimental conditions is a very promising result for potential spintronics applications, especially since it is seconded by observation of an ultrafast ferromagnetic to paramagnetic phase transition above Tc. In a different set of experiments, we "write" the magnetization in a particular orientation in the sample plane. Using an ultrafast scheme, we alter the distribution of holes in the system and detect signatures of the particular memory state in the subsequent magnetization dynamics, with unprecedented hundreds of

  14. Transient heat transfer analysis of superconducting magnetic levitating flywheel rotor operating in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Mochida, A.; Kudo, K.; Higasa, H.

    1999-07-01

    In the present study, transient temperature rise is analyzed in a flywheel type power storage system operated in vacuum environment. The flywheel rotor is levitated by high-temperature-superconducting magnetic bearing to reduce the bearing loss. Though the superconductor is cooled by liquid nitrogen, the temperature of the whole system rises due to Joule heating in the coils of the bearings and the motor during the operation. If the temperature should reach the critical temperature of the permanent magnet used for the magnetic bearings after long time operation, the magnetic bearings lose their effect. The heat generated in the levitated rotor diffuses within it by heat conduction and finally emitted to its surrounding solid materials by thermal radiation from the rotor surfaces across vacuum layer. Numerical simulation is carried out calculating the transient radiative-conductive heat transfer and time-dependent profiles of temperature within the rotor are obtained. The results are compared with the experimentally obtained temperatures by measured a test model of 1kWh power storage and the measured profiles of the temperature rise of the rotor fit very well with the calculated ones. Using this simulation tool, the effects of the surface emissivity of the materials of the rotor and the stator, the temperature of the surrounding casings and the thermal conductivity of the materials on the temperature profiles in the system are estimated.

  15. Transient birefringence effects in electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Parshkov, O M

    2015-01-01

    We report the results of numerical modelling of transient birefringence that arises as a result of electromagnetically induced transparency on degenerate quantum transitions between the states with J = 0, 1 and 2 in the presence of the Doppler broadening of spectral lines. It is shown that in the case of a linearly polarised control field, the effect of transient birefringence leads to a decay of the input circularly polarised probe pulse into separate linearly polarised pulses inside a medium. In the case of a circularly polarised control field, the effect of transient birefringence manifests itself in a decay of the input linearly polarised probe pulse into separate circularly polarised pulses. It is shown that the distance that a probe pulse has to pass in a medium before decaying into subpulses is considerably greater in the first case than in the second. The influence of the input probe pulse power and duration on the process of spatial separation into individual pulses inside a medium is studied. A qualitative analysis of the obtained results is presented. (nonlinear optical phenomena)

  16. Low-frequency transient electric and magnetic fields coupling to child body

    International Nuclear Information System (INIS)

    Ozen, S.

    2008-01-01

    Much of the research related to residential electric and magnetic field exposure focuses on cancer risk for children. But until now only little knowledge about coupling of external transient electric and magnetic fields with the child's body at low frequency transients existed. In this study, current densities, in the frequency range from 50 Hz up to 100 kHz, induced by external electric and magnetic fields to child and adult human body, were investigated, as in residential areas, electric and magnetic fields become denser in this frequency band. For the calculations of induced fields and current density, the ellipsoidal body models are used. Current density induced by the external magnetic field (1 μT) and external electric field (1 V/m) is estimated. The results of this study show that the transient electric and magnetic fields would induce higher current density in the child body than power frequency fields with similar field strength. (authors)

  17. Magnetic effects in electrochemistry

    Directory of Open Access Journals (Sweden)

    NEBOJSA D. NIKOLIC

    2005-05-01

    Full Text Available The effect of imposed magnetic fields onto the electrodeposition of magnetic (nickel and non – magnetic (copper metals was analysed. Also, magnetic properties of electrochemically obtained nanocontacts were examined. An effort to establish a possible correlation between the morphologies of the nanocontacts and the effect of the very large ballistic magnetoresistance (BMR effect was made.

  18. Transient magnetic fields of H-like ions in the range 10≤ZIon≤28

    International Nuclear Information System (INIS)

    Cub, J.

    1993-07-01

    Experiments with the hydrogen-like ions Ne-20, S-32, Ar-40, Fe-54 and Ni-62 were performed in order to measure the transient magnetic fields of the ions by perturbed angular correlation of the gamma radiation

  19. Measurement of radiation induced transients in hybrid microcircuits by magnetic thin film sensor/recorders

    International Nuclear Information System (INIS)

    Hsieh, E.J.; Vindelov, K.E.; Brown, T.G.; Miller, D.E.

    1976-01-01

    Magnetic thin film transient current sensor/recorders were modified to make two types of nuclear test measurements, transient currents in hybrid microcircuits and internal electromagnetic pulse (IEMP) fields. The measurements were made possible by the invention of split-domain sensor/recorders which can measure bilateral currents and can be reset and readout on location. The sensor/recorders were used in two underground nuclear tests and numerous calibration tests in radiation-simulation machines. The data showed that the nuclear environment had negligible effect on the sensor/recorder's operation and the recorded informations on the sensor/recorders were the signals intended to be monitored. Also, the experimental data agreed with the theoretical analysis in controlled experiments. The data were examined first by on location readout with a magnetic tape viewer and later by Kerr magneto-optic readout in the laboratory. To translate the data into current readings, we reconstructed facsimile data (on each of the sensor/recorders) in the laboratory by current pulses with the same pulse width as the radiation event. An additional check on the accuracy of the data was made by using both the sensor/recorder and the conventional pickup-oscilloscope-camera technique to monitor the same current lead in a simulated radiation environment. Over five runs were made, and the agreement among the two measurement methods was within 25%. The data collectively implied that the measurements were reliable and dependable

  20. Data Analysis of Transient Energy Releases in the LHC Superconducting Dipole Magnets

    CERN Document Server

    Calvi, M; Bottura, L; Di Castro, M; Masi, A; Siemko, A

    2007-01-01

    Premature training quenches are caused by transient energy released within the LHC dipole magnet coils while it is energized. Voltage signals recorded across the magnet coils and on the so-called quench antenna carry information about these disturbances. The transitory events correlated to transient energy released are extracted making use of continuous wavelet transform. Several analyses are performed to understand their relevance to the so called training phenomenon. The statistical distribution of the signals amplitude, the number of events occurring at a given current level, the average frequency content of the events are the main parameters on which the analysis have been focalized. Comparisons among different regions of the magnet, among different quenches in the same magnet and among magnets made by different builders are reported. Conclusions about the efficiency of the raw data treatment and the relevance of the parameters developed with respect to the magnet global behavior are finally given.

  1. Transient magnetic tunneling mediated by a molecular bridge

    Czech Academy of Sciences Publication Activity Database

    Kalvová, Anděla; Špička, Václav; Velický, B.

    2015-01-01

    Roč. 28, č. 3 (2015), 1087-1091 ISSN 1557-1939 R&D Projects: GA ČR GAP204/12/0897 Institutional support: RVO:68378271 Keywords : non-equilibrium * initial conditions * transient currents * molecular islands Subject RIV: BE - Theoretical Physics Impact factor: 1.100, year: 2015

  2. High-frequency, transient magnetic susceptibility of ferroelectrics

    Science.gov (United States)

    Grimes, Craig A.

    1996-10-01

    A significant high-frequency magnetic susceptibility was measured both in weakly polarized and nonpolarized samples of barium titanate, lead zirconate titanate, and carnauba wax. Magnetic susceptibility measurements were made from 10 to 500 MHz using a thin film permeameter at room temperature; initial susceptibilities ranged from 0.1 to 2.5. These values are larger than expected for paramagnets and smaller than expected for ferromagnets. It was found that the magnetic susceptibility decreases rapidly with exposure to the exciting field. The origin of the magnetic susceptibility is thought to originate with the applied time varying electric field associated with the susceptibility measurements. An electric field acts to rotate an electric dipole, creating a magnetic quadrupole if the two moments are balanced, and a net magnetic dipole moment if imbalanced. It is thought that local electrostatic fields created at ferroelectric domain discontinuities associated with grain boundaries create an imbalance in the anion rotation that results in a net, measurable, magnetic moment. The origin of the magnetic aftereffect may be due to the local heating of the material through the moving charges associated with the magnetic moment.

  3. The transient radiation effects and hardness of programmed device

    International Nuclear Information System (INIS)

    Du Chuanhua; Xu Xianguo; Zhao Hailin

    2014-01-01

    A review and summary of research and development in the investigation of transient ionizing radiation effects in device and cirviut is presented. The transient ionizing radiation effects in two type of programmed device, that's 32 bit Microcontroller and antifuse FPGA, were studied. The expeiment test data indicate: The transient ionizing radiation effects of 32 bit Microcontroller manifested self-motion restart and Latchup, the Latchup threshold was 5 × 10"7 Gy (Si)/s. The transient ionizing radiation effects of FPGA was reset, no Latchup. The relationship of circuit effects to physical mechanisms was analized. A new method of hardness in circiut design was put forward. (authors)

  4. Do Magnetic Fields drive high-energy explosive transients?

    OpenAIRE

    Mundell, Carole

    2017-01-01

    I will review the current state-of-the-art in real-time, rapid response optical imaging and polarimetric followup of transient sources such as Gamma Ray Bursts. I will interpret current results within the context of the external shock model and present predictions for future mm- and cm-wave radio observatories. Recent observational results from new radio pilot studies will also be presented.

  5. Do Magnetic Fields Drive High-Energy Explosive Transients?

    Science.gov (United States)

    Mundell, Carole

    2017-10-01

    I will review the current state-of-the-art in real-time, rapid response optical imaging and polarimetric followup of transient sources such as Gamma Ray Bursts. I will interpret current results within the context of the external shock model and present predictions for future mm- and cm-wave radio observatories. Recent observational results from new radio pilot studies will also be presented.

  6. Effect of transient heating loads on beryllium

    International Nuclear Information System (INIS)

    Kupriyanov, Igor B.; Porezanov, Nicolay P.; Nikolaev, Georgyi N.; Kurbatova, Liudmila A.; Podkovyrov, Vyacheslav L.; Muzichenko, Anatoliy D.; Zhitlukhin, Anatoliy M.; Khimchenko, Leonid N.; Gervash, Alexander A.

    2014-01-01

    Highlights: • We study the effect of transient plasma loads on beryllium erosion and surface microstructure. • Beryllium targets were irradiated by plasma streams with energy of 0.5–1 MJ/m 2 at ∼250 °C. • Under plasma loads 0.5–1 MJ/m 2 cracking of beryllium surface is rather slight. • Under 0.5 MJ/m 2 the mass loss of Be is no more than 0.2 g/m 2 shot and decreasing with shots number. • Under 1 MJ/m 2 maximum mass loss of beryllium was 3.7 g/m 2 shot and decreasing with shots number. - Abstract: Beryllium will be used as a plasma facing material for ITER first wall. It is expected that erosion of beryllium under transient plasma loads such as the edge-localized modes (ELMs) and disruptions will mainly determine a lifetime of ITER first wall. The results of recent experiments with the Russian beryllium of TGP-56FW ITER grade on QSPA-Be plasma gun facility are presented. The Be/CuCrZr mock-ups were exposed to upto 100 shots by deuterium plasma streams with pulse duration of 0.5 ms at ∼250 °C and average heat loads of 0.5 and 1 MJ/m 2 . Experiments were performed at 250 °C. The evolution of surface microstructure and cracks morphology as well as beryllium mass loss are investigated under erosion process

  7. Transient and intermittent magnetic reconnections in TS-3/UTST merging startup experiments

    International Nuclear Information System (INIS)

    Ono, Y.; Imazawa, R.; Imanaka, H.; Hayamizu, T.; Inomoto, M.; Sato, M.; Kawamori, E.; Ejiri, A.; Takase, Y.; Asai, T.; Takahashi, T.

    2007-01-01

    The high-power reconnection heating has been developed in the TS-3 merging experiments, leading us to a new pulsed high-beta spherical tokamak (ST) formation. Two ST plasmas were produced inductively by two or four PF coils without using any central solenoid (CS) coil and were merged together for MW-GW reconnection heating. The magnetic reconnection transformed the magnetic energy of reconnecting magnetic field through the outflow kinetic energy finally to the ion thermal energy, increasing the plasma beta of ST up to 0.5. A new finding is that ejection of current sheet (or plasmoid) causes high-speed merging/ reconnection as well as high-power heating. In the high-q ST merging, the sheet resistivity was almost classical due to the sheet thickness much longer than ion gyroradius. Large inflow flux and low current-sheet dissipation resulted in flux pileup followed by rapid growth of the current sheet. When the flux pileup exceeded a critical limit, the sheet was ejected mechanically from the squeezed X-point area. The reconnection (outflow) speed was slow during the flux pileup and was fast during the ejection, indicating that intermittent reconnection similar to the solar flare increased the averaged reconnection speed. These transient effects enable us to have the fast reconnection as well as the high-power reconnection heating, even if the merging high-q tokamaks have low current-sheet resistivity. (author)

  8. About the parametrizations utilized to perform magnetic moments measurements using the transient field technique

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, A. M., E-mail: amgomezl-1@uqvirtual.edu.co [Programa de Física, Universidad del Quindo (Colombia); Torres, D. A., E-mail: datorresg@unal.edu.co [Physics Department, Universidad Nacional de Colombia, Bogotá (Colombia)

    2016-07-07

    The experimental study of nuclear magnetic moments, using the Transient Field technique, makes use of spin-orbit hyperfine interactions to generate strong magnetic fields, above the kilo-Tesla regime, capable to create a precession of the nuclear spin. A theoretical description of such magnetic fields is still under theoretical research, and the use of parametrizations is still a common way to address the lack of theoretical information. In this contribution, a review of the main parametrizations utilized in the measurements of Nuclear Magnetic Moments will be presented, the challenges to create a theoretical description from first principles will be discussed.

  9. Transient thermal effects in Alpine permafrost

    Directory of Open Access Journals (Sweden)

    J. Noetzli

    2009-04-01

    Full Text Available In high mountain areas, permafrost is important because it influences the occurrence of natural hazards, because it has to be considered in construction practices, and because it is sensitive to climate change. The assessment of its distribution and evolution is challenging because of highly variable conditions at and below the surface, steep topography and varying climatic conditions. This paper presents a systematic investigation of effects of topography and climate variability that are important for subsurface temperatures in Alpine bedrock permafrost. We studied the effects of both, past and projected future ground surface temperature variations on the basis of numerical experimentation with simplified mountain topography in order to demonstrate the principal effects. The modeling approach applied combines a distributed surface energy balance model and a three-dimensional subsurface heat conduction scheme. Results show that the past climate variations that essentially influence present-day permafrost temperatures at depth of the idealized mountains are the last glacial period and the major fluctuations in the past millennium. Transient effects from projected future warming, however, are likely larger than those from past climate conditions because larger temperature changes at the surface occur in shorter time periods. We further demonstrate the accelerating influence of multi-lateral warming in steep and complex topography for a temperature signal entering the subsurface as compared to the situation in flat areas. The effects of varying and uncertain material properties (i.e., thermal properties, porosity, and freezing characteristics on the subsurface temperature field were examined in sensitivity studies. A considerable influence of latent heat due to water in low-porosity bedrock was only shown for simulations over time periods of decades to centuries. At the end, the model was applied to the topographic setting of the Matterhorn

  10. Nonlinear Modeling of Forced Magnetic Reconnection with Transient Perturbations

    Science.gov (United States)

    Beidler, Matthew T.; Callen, James D.; Hegna, Chris C.; Sovinec, Carl R.

    2017-10-01

    Externally applied 3D magnetic fields in tokamaks can penetrate into the plasma and lead to forced magnetic reconnection, and hence magnetic islands, on resonant surfaces. Analytic theory has been reasonably successful in describing many aspects of this paradigm with regard to describing the time asymptotic-steady state. However, understanding the nonlinear evolution into a low-slip, field-penetrated state, especially how MHD events such as sawteeth and ELMs precipitate this transition, is in its early development. We present nonlinear computations employing the extended-MHD code NIMROD, building on previous work by incorporating a temporally varying external perturbation as a simple model for an MHD event that produces resonant magnetic signals. A parametric series of proof-of-principle computations and accompanying analytical theory characterize the transition into a mode-locked state with an emphasis on detailing the temporal evolution properties. Supported by DOE OFES Grants DE-FG02-92ER54139, DE-FG02-86ER53218, and the U.S. DOE FES Postdoctoral Research program administered by ORISE and managed by ORAU under DOE contract DE-SC0014664.

  11. Transient growth of a Vlasov plasma in a weakly inhomogeneous magnetic field

    KAUST Repository

    Ratushnaya, Valeria

    2016-12-17

    We investigate the stability properties of a collisionless Vlasov plasma in a weakly inhomogeneous magnetic field using non-modal stability analysis. This is an important topic in a physics of tokamak plasma rich in various types of instabilities. We consider a thin tokamak plasma in a Maxwellian equilibrium, subjected to a small arbitrary perturbation. Within the framework of kinetic theory, we demonstrate the emergence of short time scale algebraic instabilities evolving in a stable magnetized plasma. We show that the linearized governing operator (Vlasov operator) is non-normal leading to the transient growth of the perturbations on the time scale of several plasma periods that is subsequently followed by Landau damping. We calculate the first-order distribution function and the electric field and study the dependence of the transient growth characteristics on the magnetic field strength and perturbation parameters of the system. We compare our results with uniformly magnetized plasma and field-free Vlasov plasma.

  12. Transient growth of a Vlasov plasma in a weakly inhomogeneous magnetic field

    KAUST Repository

    Ratushnaya, Valeria; Samtaney, Ravi

    2016-01-01

    We investigate the stability properties of a collisionless Vlasov plasma in a weakly inhomogeneous magnetic field using non-modal stability analysis. This is an important topic in a physics of tokamak plasma rich in various types of instabilities. We consider a thin tokamak plasma in a Maxwellian equilibrium, subjected to a small arbitrary perturbation. Within the framework of kinetic theory, we demonstrate the emergence of short time scale algebraic instabilities evolving in a stable magnetized plasma. We show that the linearized governing operator (Vlasov operator) is non-normal leading to the transient growth of the perturbations on the time scale of several plasma periods that is subsequently followed by Landau damping. We calculate the first-order distribution function and the electric field and study the dependence of the transient growth characteristics on the magnetic field strength and perturbation parameters of the system. We compare our results with uniformly magnetized plasma and field-free Vlasov plasma.

  13. Diffusion magnetic resonance imaging in transient global amnesia

    Energy Technology Data Exchange (ETDEWEB)

    Godeiro-Junior, Clecio; Miranda-Alves, Maramelia Araujo de [Federal University of Sao Paulo (UNIFESP-EPM), Sao Paulo SP (Brazil). Dept. of Neurology and Neurosurgery], e-mail: cleciojunior@yahoo.com.br; Massaro, Ayrton Roberto [Fleury Diagnostic Center, Sao Paulo SP (Brazil)

    2009-03-15

    Transient global amnesia (TGA) is a well known clinical entity characterized by anterograde memory disturbance of sudden onset that lasts 1 to 24 hours. Orientation in space and time is impaired while consciousness remains undisturbed. TGA may refer to a single expression of several physiopathological phenomena. Conceptually, cerebral ischemia, epileptic discharge, and migraine constitute the main pathogenic hypothesis. Diffusion-weighted imaging (DWI) has become a powerful tool in the evaluation of patients with suspected stroke owing to its high sensitivity and specificity, even for small areas of acute ischemia. Consequently, this method has also been applied to TGA to gain further insights into the ischemic hypothesis of this condition. We report a patient with a typical TGA presentation and MRI findings suggestive of an ischemic insult. We further discuss the ischemic hypothesis of TGA. (author)

  14. Diffusion magnetic resonance imaging in transient global amnesia

    International Nuclear Information System (INIS)

    Godeiro-Junior, Clecio; Miranda-Alves, Maramelia Araujo de

    2009-01-01

    Transient global amnesia (TGA) is a well known clinical entity characterized by anterograde memory disturbance of sudden onset that lasts 1 to 24 hours. Orientation in space and time is impaired while consciousness remains undisturbed. TGA may refer to a single expression of several physiopathological phenomena. Conceptually, cerebral ischemia, epileptic discharge, and migraine constitute the main pathogenic hypothesis. Diffusion-weighted imaging (DWI) has become a powerful tool in the evaluation of patients with suspected stroke owing to its high sensitivity and specificity, even for small areas of acute ischemia. Consequently, this method has also been applied to TGA to gain further insights into the ischemic hypothesis of this condition. We report a patient with a typical TGA presentation and MRI findings suggestive of an ischemic insult. We further discuss the ischemic hypothesis of TGA. (author)

  15. Transient events at the magnetopause and bipolar magnetic signatures

    Czech Academy of Sciences Publication Activity Database

    Krupařová, Oksana; Šafránková, J.; Němeček, Z.; Přech, L.

    2015-01-01

    Roč. 115, September (2015), s. 19-26 ISSN 0032-0633 R&D Projects: GA ČR(CZ) GA14-19376S; GA ČR GP13-37174P Institutional support: RVO:68378289 Keywords : flux transfer events * magnetopause deformation * magnetosheath * fluctuations * magnetic reconnection * foreshock bubbles Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.942, year: 2015 http://www.sciencedirect.com/science/article/pii/S0032063315000434#

  16. Effects of glycyrrhizin pre-treatment on transient ischemic brain ...

    African Journals Online (AJOL)

    Effects of glycyrrhizin pre-treatment on transient ischemic brain injury in mice. ... on transient ischemic brain injury in mice. Chiyeon Lim, Sehyun Lim, Young-Jun Lee, Bokcheul Kong, Byoungho Lee, Chang-Hyun Kim, Buyeo Kim, Suin Cho ... induced brain damage. Keywords: Glycyrrhizin, licorice, stroke, apoptosis ...

  17. The Relevance of the Dynamic Stall Effect for Transient

    DEFF Research Database (Denmark)

    Jauch, Clemens; Sørensen, Poul; Bak-Jensen, Birgitte

    2005-01-01

    This article describes a methodology to quantify the influence of dynamic stall on transient fault operations of active-stall turbines. The model of the dynamic stall effect is introduced briefly. The behaviour of the dynamic stall model during a transient fault operation is described mathematica...

  18. Effective magnetic Hamiltonians

    Czech Academy of Sciences Publication Activity Database

    Drchal, Václav; Kudrnovský, Josef; Turek, I.

    2013-01-01

    Roč. 26, č. 5 (2013), s. 1997-2000 ISSN 1557-1939 R&D Projects: GA ČR GA202/09/0775 Institutional support: RVO:68378271 Keywords : effective magnetic Hamiltonian * ab initio * magnetic structure Subject RIV: BE - Theoretical Physics Impact factor: 0.930, year: 2013

  19. Modeling transient radiation effects in power MOSFETS

    International Nuclear Information System (INIS)

    Hoffman, J.R.; Hall, W.E.; Dunn, D.E.

    1987-01-01

    Using standard device specifications and simple assumptions, the transient radiation response of VDMOS MOSFETs can be modeled in a standard circuit analysis program. The device model consists of a body diode, a parasitic bipolar transistor, and elements to simulate high-current reduced breakdown. The attached photocurrent model emulates response to any pulse shape and accounts for bias-dependent depletion regions. The model can be optimized to best fit available test data

  20. On transient effects in violent nuclear collisions

    International Nuclear Information System (INIS)

    Suraud, E.; Belkacem, M.; Feng-Shou Zhang; Academia Sinica, Lanzhou, GS

    1993-01-01

    It is shown that the numerical simulations of the recently developed Boltzmann-Langevin model exhibit large dynamical fluctuations in momentum space during the early stages of heavy-ion collisions, which arise from an interplay between the nuclear meanfield and binary collisions. It is pointed out that this transient behaviour provides an initial seed for the development of density fluctuations, and could strongly influence the particle production cross-sections at subthreshold energies. (author) 13 refs.; 3 figs

  1. Magnetization effects in superconducting dipole magnets

    International Nuclear Information System (INIS)

    Ishimoto, H.; Peters, R.E.; Price, M.E.; Yamada, R.

    1977-01-01

    Magnetization effect of superconductors on the field quality was investigated for some of the typical Energy Doubler bending magnets. Calculations were made using the computor program GFUN2D and compared with some measured results. Agreement between them is good. The field quality at low excitation is mainly determined by the magnetization effect. A similar effect due to a stainless collar mechanical support was also calculated, although it is not as big as the first one

  2. Transient Perturbations and their Effects in the Heliosphere, the Geo ...

    Indian Academy of Sciences (India)

    tures of transient perturbations related to space weather effects. Relation- ships between ... or health (e.g., see Kudela et al. 2000). Spacecraft systems ... storms. Precursors to Forbush decreases are of practical interest as possible predictors ...

  3. Topside ionosphere of Mars: Variability, transient layers, and the role of crustal magnetic fields

    Science.gov (United States)

    Gopika, P. G.; Venkateswara Rao, N.

    2018-04-01

    The topside ionosphere of Mars is known to show variability and transient topside layers. In this study, we analyzed the electron density profiles measured by the radio occultation technique aboard the Mars Global Surveyor spacecraft to study the topside ionosphere of Mars. The electron density profiles that we used in the present study span between 1998 and 2005. All the measurements are done from the northern high latitudes, except 220 profiles which were measured in the southern hemisphere, where strong crustal magnetic fields are present. We binned the observations into six measurement periods: 1998, 1999-north, 1999-south, 2000-2001, 2002-2003, and 2004-2005. We found that the topside ionosphere in the southern high latitudes is more variable than that from the northern hemisphere. This feature is clearly seen with fluctuations of wavelengths less than 20 km. Some of the electron density profiles show a transient topside layer with a local maximum in electron density between 160 km and 210 km. The topside layer is more prone to occur in the southern hemispheric crustal magnetic field regions than in the other regions. In addition, the peak density of the topside layer is greater in regions of strong crustal magnetic fields than in other regions. The variability of the topside ionosphere and the peak density of the topside layer, however, do not show one-to-one correlation with the strength of the crustal magnetic fields and magnetic field inclination. The results of the present study are discussed in the light of current understanding on the topside ionosphere, transient topside layers, and the role of crustal magnetic fields on plasma motions.

  4. Transient Behaviour of Superconducting Magnet Systems of Fusion Reactor ITER during Safety Discharge

    Directory of Open Access Journals (Sweden)

    A. M. Miri

    2008-01-01

    Full Text Available To investigate the transient behaviour of the toroidal and poloidal field coils magnet systems of the International Thermonuclear Experimental Reactor during safety discharge, network models with lumped elements are established. Frequency-dependant values of the network elements, that is, inductances and resistances are calculated with the finite element method. That way, overvoltages can be determined. According to these overvoltages, the insulation coordination of coils has to be selected.

  5. Investigation of Thermal and Vacuum Transients on the LHC Prototype Magnet String

    CERN Document Server

    Cruikshank, P; Riddone, G; Tavian, L

    1996-01-01

    The prototype magnet string, described in a companion paper, is a full-scale working model of a 50-m length of the future Large Hadron Collider (LHC), CERN's new accelerator project, which will use high-field superconducting magnets operating below 2 K in superfluid helium. As such, it provides an excellent test bed for practising standard operating modes of LHC insulation vacuum and cryogenics, as well as for experimentally assessing accidental behaviour and failure modes, and thus verifying design calculations. We present experimental investigation of insulation vacuum pumpdown, magnet forced-flow cooldown and warmup, and evolution of residual vacuum pressures and temperatures in natural warmup, as well as catastrophic loss of insulation vacuum. In all these transient modes, experimental results are compared with simulated behaviour, using a non-linear, one-dimensional thermal model of the magnet string.

  6. THE EFFECT OF TRANSIENT ACCRETION ON THE SPIN-UP OF MILLISECOND PULSARS

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharyya, Sudip; Chakrabarty, Deepto, E-mail: sudip@tifr.res.in [Department of Astronomy and Astrophysics, Tata Institute of Fundamental Research, 1 Homi Bhabha Road, Colaba, Mumbai 400005 (India)

    2017-01-20

    A millisecond pulsar is a neutron star that has been substantially spun up by accretion from a binary companion. A previously unrecognized factor governing the spin evolution of such pulsars is the crucial effect of nonsteady or transient accretion. We numerically compute the evolution of accreting neutron stars through a series of outburst and quiescent phases, considering the drastic variation of the accretion rate and the standard disk–magnetosphere interaction. We find that, for the same long-term average accretion rate, X-ray transients can spin up pulsars to rates several times higher than can persistent accretors, even when the spin-down due to electromagnetic radiation during quiescence is included. We also compute an analytical expression for the equilibrium spin frequency in transients, by taking spin equilibrium to mean that no net angular momentum is transferred to the neutron star in each outburst cycle. We find that the equilibrium spin rate for transients, which depends on the peak accretion rate during outbursts, can be much higher than that for persistent sources. This explains our numerical finding. This finding implies that any meaningful study of neutron star spin and magnetic field distributions requires the inclusion of the transient accretion effect, since most accreting neutron star sources are transients. Our finding also implies the existence of a submillisecond pulsar population, which is not observed. This may point to the need for a competing spin-down mechanism for the fastest-rotating accreting pulsars, such as gravitational radiation.

  7. Electrical effects of transient neutron irradiation of silicon devices

    International Nuclear Information System (INIS)

    Hjalmarson, H.P.; Pease, R.L.; Van Ginhoven, R.M.; Schultz, P.A.; Modine, N.A.

    2007-01-01

    The key effects of combined transient neutron and ionizing radiation on silicon diodes and bipolar junctions transistors are described. The results show that interstitial defect reactions dominate the annealing effects in the first stage of annealing for certain devices. Furthermore, the results show that oxide trapped charge can influence the effects of bulk silicon displacement damage for particular devices

  8. Transient Simulation of a Rotating Conducting Cylinder in a Transverse Magnetic Field

    Science.gov (United States)

    2016-09-01

    the boundary conditions and magnetic field excitation. The balloon (no fringing at infinity ) boundary condition is used for the model. Two magnetic...cylinder to study the effects of the magnetic responses of the cylinder in the time history . Table 1 summarizes the electromagnetic properties of the...and phase shift angles of the magnetic flux density in the time history , at the center of the structural steel, aluminum, and copper cylinder

  9. Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis.

    Science.gov (United States)

    Masuzawa, Toru; Ohta, Akiko; Tanaka, Nobuatu; Qian, Yi; Tsukiya, Tomonori

    2009-01-01

    The effect of the hydraulic force on magnetically levitated (maglev) pumps should be studied carefully to improve the suspension performance and the reliability of the pumps. A maglev centrifugal pump, developed at Ibaraki University, was modeled with 926 376 hexahedral elements for computational fluid dynamics (CFD) analyses. The pump has a fully open six-vane impeller with a diameter of 72.5 mm. A self-bearing motor suspends the impeller in the radial direction. The maximum pressure head and flow rate were 250 mmHg and 14 l/min, respectively. First, a steady-state analysis was performed using commercial code STAR-CD to confirm the model's suitability by comparing the results with the real pump performance. Second, transient analysis was performed to estimate the hydraulic force on the levitated impeller. The impeller was rotated in steps of 1 degrees using a sliding mesh. The force around the impeller was integrated at every step. The transient analysis revealed that the direction of the radial force changed dynamically as the vane's position changed relative to the outlet port during one circulation, and the magnitude of this force was about 1 N. The current maglev pump has sufficient performance to counteract this hydraulic force. Transient CFD analysis is not only useful for observing dynamic flow conditions in a centrifugal pump but is also effective for obtaining information about the levitation dynamics of a maglev pump.

  10. In beam test of a transient magnetic field based g factor setup

    International Nuclear Information System (INIS)

    Saxena, Mansi; Mandal, S.; Siwal, Davinder; Kumar, Chandan; Goyal, Savi; Garg, Ritika; Khushboo; Rohilla, Aman; Kumar, Naveen; Kumar, S.; Chamoli, S.; Mandal, A.; Kumar, Rajesh; Barua, P.; Kumar, R.; Gujjar, R.; Bala, Indu; Singh, R.P.; Muralithar, S.; Rehman, Anisur; Roy, Minakshi

    2012-01-01

    Magnetic moments or g factors provide substantial information on the microscopic structure of the nuclei. Since the g factor is very different in sign and magnitude for neutrons and protons, therefore they can serve as a good indicator as to which nucleon contributes most to the wave function of that state. There are different techniques available for measuring g factors depending on the lifetime of the state involved. Using transient field technique we can measure the g factor of nuclei having a lifetime of the order of several hundreds of femto seconds. To measure the g factor of such low lifetime states we have designed and fabricated a setup based on the Transient Field Technique Measurement

  11. TRANSIENT BEAM LOADING EFFECTS IN RF SYSTEMS IN JLEIC

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Haipeng [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Guo, Jiquan [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Rimmer, Robert A. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Wang, Shaoheng [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-05-01

    The pulsed electron bunch trains generated from the Continuous Electron Beam Accelerator Facility (CEBAF) linac to inject into the proposed Jefferson Lab Electron Ion Collider (JLEIC) e-ring will produce transient beam loading effects in the Superconducting Radio Frequency (SRF) systems that, if not mitigated, could cause unacceptably large beam energy deviation in the injection capture, or exceed the energy acceptance of CEBAF’s recirculating arcs. In the electron storage ring, the beam abort or ion clearing gaps or uneven bucket filling can cause large beam phase transients in the (S)RF cavity control systems and even beam loss due to Robinson instability. We have first analysed the beam stability criteria in steady state and estimated the transient effect in Feedforward and Feedback RF controls. Initial analytical models for these effects are shown for the design of the JLEIC e-ring from 3GeV to 12GeV.

  12. Dayside magnetopause transients correlated with changes of the magnetosheath magnetic field orientation

    Directory of Open Access Journals (Sweden)

    O. Tkachenko

    2011-04-01

    Full Text Available The paper analyses one long-term pass (26 August 2007 of the THEMIS spacecraft across the dayside low-latitude magnetopause. THEMIS B, serving partly as a magnetosheath monitor, observed several changes of the magnetic field that were accompanied by dynamic changes of the magnetopause location and/or the structure of magnetopause layers observed by THEMIS C, D, and E, whereas THEMIS A scanned the inner magnetosphere. We discuss the plasma and the magnetic field data with motivation to identify sources of observed quasiperiodic plasma transients. Such events at the magnetopause are usually attributed to pressure pulses coming from the solar wind, foreshock fluctuations, flux transfer events or surface waves. The presented transient events differ in nature (the magnetopause surface deformation, the low-latitude boundary layer thickening, the crossing of the reconnection site, but we found that all of them are associated with changes of the magnetosheath magnetic field orientation and with enhancements or depressions of the plasma density. Since these features are not observed in the data of upstream monitors, the study emphasizes the role of magnetosheath fluctuations in the solar wind-magnetosphere coupling.

  13. Velocity dependence of transient hyperfine field at Pt ions rapidly recoiling through magnetized Fe

    International Nuclear Information System (INIS)

    Stuchbery, A.E.; Ryan, C.G.; Bolotin, H.H.

    1981-01-01

    The velocity-dependence of the transient hyperfine magnetic field acting at nuclei of 196 Pt ions rapidly recoiling through thin magnetized Fe was investigated at a number of recoil velocities. The state of interest (2 1 + ) was populated by Coulomb excitation using beams of 80- and 120-MeV 32 S and 150- and 220-MeV 58 Ni ions. The 2 1 + →0 1 + γ-ray angular distribution precession measurements were carried out in coincidence with backscattered projectiles. From these results, the strength of the transient field acting on Pt ions recoiling through magnetized Fe with average velocities in the extended range 2.14<=v/vsub(o)<=4.82 (vsub(o) = c/137) was found to be consistent with a linear velocity dependence and to be incompatible with the specific vsup(0.45+-0.18) dependence which has been previously reported to account well for all ions in the mass range from oxygen through samarium. This seemingly singular behaviour for Pt and other ions in the Pt mass vicinity is discussed

  14. Effect of transient postpubertal hypo- and hyperthyroidism on ...

    African Journals Online (AJOL)

    Effect of transient postpubertal hypo- and hyperthyroidism on reproductive parameters of Iranian broiler breeder hens. ... Egg number, fertility, hatchability, grading of day-old chicks and embryonic developmental stage of unhatched eggs were determined for individual artificially inseminated hen. Effects of PTU and T4 ...

  15. Transient loss of plasma from a theta pinch having an initially reversed magnetic field

    International Nuclear Information System (INIS)

    Heidrich, J.E.

    1981-01-01

    The results of an experimental study of the transient loss of plasma from a 25-cm-long theta pinch initially containing a reversed trapped magnetic field are presented. The plasma, amenable to MHD analyses, was a doubly ionized helium plasma characterized by an ion density N/sub i/ = 2 x 10 16 cm -3 and an ion temperature T/sub i/ = 15 eV at midcoil and by N/sub i/ = 0.5 x 10 16 cm -3 and T/sub i/ = 6 eV at a position 2.5 cm beyond the end of the theta coil

  16. Study on shadowing effect caused by transient rods at NSRR

    International Nuclear Information System (INIS)

    Nakamura, T.; Yachi, S.; Ishijima, K.

    1992-01-01

    Irregularly inserted three control rods created so called shadowing effects on some of the neutronic instruments at the Nuclear Safety Research Reactor (NSRR). During operations at the reactor power of up to 10 MW, the three control rods called transient rods, could be fully or partly inserted into the NSRR core. Reactor power monitors located outside of the core at the direction of deeply inserted transient rods indicated lower power in such operations. Power profiles of the reactor and neutron fluxes at power monitor locations were calculated with a three dimensional neutron diffusion code, CITATION. The calculation indicated that the real reactor power could be smaller than the measured maximum power by as mush as 30 % in such operations. The calculated neutron fluxes well described the changes in the apparent power monitor indications as a function of the transient rod position. (author)

  17. Cerebellar transcranial static magnetic field stimulation transiently reduces cerebellar brain inhibition.

    Science.gov (United States)

    Matsugi, Akiyoshi; Okada, Y

    The aim of this study was to investigate whether transcranial static magnetic field stimulation (tSMS) delivered using a compact cylindrical NdFeB magnet over the cerebellum modulates the excitability of the cerebellum and contralateral primary motor cortex, as measured using cerebellar brain inhibition (CBI), motor evoked potentials (MEPs), and resting motor threshold (rMT). These parameters were measured before tSMS or sham stimulation and immediately, 5 minutes and 10 minutes after stimulation. There were no significant changes in CBI, MEPs or rMT over time in the sham stimulation condition, and no changes in MEPs or rMT in the tSMS condition. However, CBI was significantly decreased immediately after tSMS as compared to that before and 5 minutes after tSMS. Our results suggest that tSMS delivered to the cerebellar hemisphere transiently reduces cerebellar inhibitory output but does not affect the excitability of the contralateral motor cortex.

  18. MSCAP [Magnet System Circuitry Analysis Program] simulations of TESPE magnet safety transients

    International Nuclear Information System (INIS)

    Herring, J.S.; Juengst, K.P.; Jones, J.L.; Kraus, H.G.

    1988-01-01

    During 1987, a series of tests were carried out on the TESPE Facility at the Institut fuer Technische Physik of the Kernforschungszentrum Karlsruhe in conjunction with the Idaho National Engineering Laboratory (INEL) to experimentally and analytically investigate arcing phenomena in high field superconducting magnets. One objective of the tests was to verify computer code simulations of the magnet system. TESPE is a six coil, NbTi, toroidal magnet set, designed to operate with 7 T and 8.3 MJ at 7000 A. The full TESPE circuit was modeled for four series of experiments: internal shorts during charge and discharge, arcs initiated by electrode separation, arcs initiated by a vaporizing wire, and arcs moving along two rails. 3 refs., 15 figs., 1 tab

  19. Helioseismic Effects of Energetic Transients Ashok Ambastha

    Indian Academy of Sciences (India)

    NOAA 10486 on 2003 October 28 and 29 (Fig. 4). Interestingly, these acoustic sources were strongly associated with the foot-points of a coronal loop that hosted the flares and hard X-ray signatures. 3.3 Amplification of p-mode power by flares in NOAA 10486. The effect of flares on solar oscillation modes has been explored ...

  20. Effects of transient hypo- and hyper-thyroidism on growth ...

    African Journals Online (AJOL)

    In order to investigate the effects of transient hypo- and hyperthyroidism on growth performance, organ weights and serum thyroid hormones of broilers, 120 one-day-old broiler chicks were randomly divided into four dietary treatments for six weeks. The dietary treatments included: 1) control, 2) hypothyroid (hypo; ...

  1. Transient Hypothyroidism During Lactation Arrests Myelination in the Anterior Commissure of Rats. A Magnetic Resonance Image and Electron Microscope Study.

    Science.gov (United States)

    Lucia, Federico S; Pacheco-Torres, Jesús; González-Granero, Susana; Canals, Santiago; Obregón, María-Jesús; García-Verdugo, José M; Berbel, Pere

    2018-01-01

    Thyroid hormone deficiency at early postnatal ages affects the cytoarchitecture and function of neocortical and telencephalic limbic areas, leading to impaired associative memory and in a wide spectrum of neurological and mental diseases. Neocortical areas project interhemispheric axons mostly through the corpus callosum and to a lesser extent through the anterior commissure (AC), while limbic areas mostly project through the AC and hippocampal commissures. Functional magnetic resonance data from children with late diagnosed congenital hypothyroidism and abnormal verbal memory processing, suggest altered ipsilateral and contralateral telencephalic connections. Gestational hypothyroidism affects AC development but the possible effect of transient and chronic postnatal hypothyroidism, as occurs in late diagnosed neonates with congenital hypothyroidism and in children growing up in iodine deficient areas, still remains unknown. We studied AC development using in vivo magnetic resonance imaging and electron microscopy in hypothyroid and control male rats. Four groups of methimazole (MMI) treated rats were studied. One group was MMI-treated from postnatal day (P) 0 to P21; some of these rats were also treated with L-thyroxine (T4) from P15 to P21, as a model for early transient hypothyroidism. Other rats were MMI-treated from P0 to P150 and from embryonic day (E) 10 to P170, as a chronic hypothyroidism group. The results were compared with age paired control rats. The normalized T2 signal using magnetic resonance image was higher in MMI-treated rats and correlated with the number and percentage of myelinated axons. Using electron microscopy, we observed decreased myelinated axon number and density in transient and chronic hypothyroid rats at P150, unmyelinated axon number increased slightly in chronic hypothyroid rats. In MMI-treated rats, the myelinated axon g-ratio and conduction velocity was similar to control rats, but with a decrease in conduction delays. These

  2. Transient Hypothyroidism During Lactation Arrests Myelination in the Anterior Commissure of Rats. A Magnetic Resonance Image and Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Federico S. Lucia

    2018-04-01

    Full Text Available Thyroid hormone deficiency at early postnatal ages affects the cytoarchitecture and function of neocortical and telencephalic limbic areas, leading to impaired associative memory and in a wide spectrum of neurological and mental diseases. Neocortical areas project interhemispheric axons mostly through the corpus callosum and to a lesser extent through the anterior commissure (AC, while limbic areas mostly project through the AC and hippocampal commissures. Functional magnetic resonance data from children with late diagnosed congenital hypothyroidism and abnormal verbal memory processing, suggest altered ipsilateral and contralateral telencephalic connections. Gestational hypothyroidism affects AC development but the possible effect of transient and chronic postnatal hypothyroidism, as occurs in late diagnosed neonates with congenital hypothyroidism and in children growing up in iodine deficient areas, still remains unknown. We studied AC development using in vivo magnetic resonance imaging and electron microscopy in hypothyroid and control male rats. Four groups of methimazole (MMI treated rats were studied. One group was MMI-treated from postnatal day (P 0 to P21; some of these rats were also treated with L-thyroxine (T4 from P15 to P21, as a model for early transient hypothyroidism. Other rats were MMI-treated from P0 to P150 and from embryonic day (E 10 to P170, as a chronic hypothyroidism group. The results were compared with age paired control rats. The normalized T2 signal using magnetic resonance image was higher in MMI-treated rats and correlated with the number and percentage of myelinated axons. Using electron microscopy, we observed decreased myelinated axon number and density in transient and chronic hypothyroid rats at P150, unmyelinated axon number increased slightly in chronic hypothyroid rats. In MMI-treated rats, the myelinated axon g-ratio and conduction velocity was similar to control rats, but with a decrease in conduction

  3. Transient rotation of photospheric vector magnetic fields associated with a solar flare.

    Science.gov (United States)

    Xu, Yan; Cao, Wenda; Ahn, Kwangsu; Jing, Ju; Liu, Chang; Chae, Jongchul; Huang, Nengyi; Deng, Na; Gary, Dale E; Wang, Haimin

    2018-01-03

    As one of the most violent eruptions on the Sun, flares are believed to be powered by magnetic reconnection. The fundamental physics involving the release, transfer, and deposition of energy have been studied extensively. Taking advantage of the unprecedented resolution provided by the 1.6 m Goode Solar Telescope, here, we show a sudden rotation of vector magnetic fields, about 12-20° counterclockwise, associated with a flare. Unlike the permanent changes reported previously, the azimuth-angle change is transient and cospatial/temporal with Hα emission. The measured azimuth angle becomes closer to that in potential fields suggesting untwist of flare loops. The magnetograms were obtained in the near infrared at 1.56 μm, which is minimally affected by flare emission and no intensity profile change was detected. We believe that these transient changes are real and discuss the possible explanations in which the high-energy electron beams or Alfve'n waves play a crucial role.

  4. Are interplanetary magnetic clouds manifestations of coronal transients at 1 AU

    International Nuclear Information System (INIS)

    Wilson, R.M.; Hildner, E.

    1984-01-01

    Using proxy data for the occurrence of those mass ejections from the solar corona which are directed earthward, we investigate the association between the post-1970 interplanetary magnetic clouds of Klein and Burlaga (1982) and coronal mass ejections. The evidence linking magnetic clouds following shocks with coronal mass ejections is striking; six of nine clouds observed at Earth were preceded an appropriate time earlier by meter-wave type II radio bursts indicative of coronal shock waves and coronal mass ejections occurring near central meridian. During the selected control periods when no clouds were detected near Earth, the only type II bursts reported were associated with solar activity near the limbs. Where the proxy solar data to be sought are not so clearly suggested, that is, for clouds preceding interaction regions and clouds within cold magnetic enhancements, the evidence linking the clouds and coronal mass ejections is not as clear; proxy data usually suggest many candidate mass-ejection events for each cloud. Overall, the data are consistent with and support the hypothesis suggested by Klein and Burlaga that magnetic clouds observed with spacecraft at 1 AU are manifestations of solar coronal mass ejection transients. (orig.)

  5. Surface Effects in Magnetic Nanoparticles

    CERN Document Server

    Fiorani, Dino

    2005-01-01

    This volume is a collection of articles on different approaches to the investigation of surface effects on nanosized magnetic materials, with special emphasis on magnetic nanoparticles. The book aims to provide an overview of progress in the understanding of surface properties and surface driven effects in magnetic nanoparticles through recent results of different modeling, simulation, and experimental investigations.

  6. Non-modal stability analysis and transient growth in a magnetized Vlasov plasma

    KAUST Repository

    Ratushnaya, V.

    2014-12-01

    Collisionless plasmas, such as those encountered in tokamaks, exhibit a rich variety of instabilities. The physical origin, triggering mechanisms and fundamental understanding of many plasma instabilities, however, are still open problems. We investigate the stability properties of a 3-dimensional collisionless Vlasov plasma in a stationary homogeneous magnetic field. We narrow the scope of our investigation to the case of Maxwellian plasma and examine its evolution with an electrostatic approximation. For the first time using a fully kinetic approach we show the emergence of the local instability, a transient growth, followed by classical Landau damping in a stable magnetized plasma. We show that the linearized Vlasov operator is non-normal leading to the algebraic growth of the perturbations using non-modal stability theory. The typical time scales of the obtained instabilities are of the order of several plasma periods. The first-order distribution function and the corresponding electric field are calculated and the dependence on the magnetic field and perturbation parameters is studied. Our results offer a new scenario of the emergence and development of plasma instabilities on the kinetic scale.

  7. Non-modal stability analysis and transient growth in a magnetized Vlasov plasma

    KAUST Repository

    Ratushnaya, V.; Samtaney, Ravi

    2014-01-01

    Collisionless plasmas, such as those encountered in tokamaks, exhibit a rich variety of instabilities. The physical origin, triggering mechanisms and fundamental understanding of many plasma instabilities, however, are still open problems. We investigate the stability properties of a 3-dimensional collisionless Vlasov plasma in a stationary homogeneous magnetic field. We narrow the scope of our investigation to the case of Maxwellian plasma and examine its evolution with an electrostatic approximation. For the first time using a fully kinetic approach we show the emergence of the local instability, a transient growth, followed by classical Landau damping in a stable magnetized plasma. We show that the linearized Vlasov operator is non-normal leading to the algebraic growth of the perturbations using non-modal stability theory. The typical time scales of the obtained instabilities are of the order of several plasma periods. The first-order distribution function and the corresponding electric field are calculated and the dependence on the magnetic field and perturbation parameters is studied. Our results offer a new scenario of the emergence and development of plasma instabilities on the kinetic scale.

  8. Experimental research on transient ionizing radiation effects of CMOS microcontroller

    International Nuclear Information System (INIS)

    Jin Xiaoming; Fan Ruyu; Chen Wei; Wang Guizhen; Lin Dongsheng; Yang Shanchao; Bai Xiaoyan

    2010-01-01

    This paper presents an experimental test system of CMOS microcontroller EE80C196KC20. Based on this system, the transient ionizing radiation effects on microcontroller were investigated using 'Qiangguang-I' accelerator. The gamma pulse width was 20 ns and the dose rate (for the Si atom) was in the range of 6.7 x 10 6 to 2.0 x 10 8 Gy/s in the experimental study. The disturbance and latchup effects were observed at different dose rate levels. Latchup threshold of the microcontroller was obtained. Disturbance interval and the system power supply current have a relationship with the dose rate level. The transient ionizing radiation induces photocurrent in the PN junctions that are inherent in CMOS circuits. The photocurrent is responsible for the electrical and functional degradation. (authors)

  9. Chiral magnetic effect of light

    Science.gov (United States)

    Hayata, Tomoya

    2018-05-01

    We study a photonic analog of the chiral magnetic (vortical) effect. We discuss that the vector component of magnetoelectric tensors plays a role of "vector potential," and its rotation is understood as "magnetic field" of a light. Using the geometrical optics approximation, we show that "magnetic fields" cause an anomalous shift of a wave packet of a light through an interplay with the Berry curvature of photons. The mechanism is the same as that of the chiral magnetic (vortical) effect of a chiral fermion, so that we term the anomalous shift "chiral magnetic effect of a light." We further study the chiral magnetic effect of a light beyond geometric optics by directly solving the transmission problem of a wave packet at a surface of a magnetoelectric material. We show that the experimental signal of the chiral magnetic effect of a light is the nonvanishing of transverse displacements for the beam normally incident to a magnetoelectric material.

  10. Abnormalities on diffusion-weighted magnetic resonance imaging in patients with transient ischemic attack

    International Nuclear Information System (INIS)

    Nakamura, Tomomi; Shibagaki, Yasuro; Uchiyama, Shinichiro; Iwata, Makoto

    2003-01-01

    We studied abnormalities on diffusion-weighted magnetic resonance imaging (DWI) in patients with transient ischemic attack (TIA). Out of 18 consecutive TIA patients, 9 patients had relevant focal abnormalities on DWI. Among TIA patients, six patients were associated with atrial fibrillation (Af), and all of these patients had focal abnormalities on DWI as well. TIA patients with Af had significantly more frequent focal abnormalities on DWI than those without Af (p=0.009; Fisher's exact probability test). In addition, the duration of TIA symptoms was not related to the presence of focal abnormalities on DWI. These results indicate that embolic mechanism may cause focal abnormalities on DWI. DWI was more sensitive to detect responsible ischemic lesions in these patients than T2-weighted image or fluid-attenuated inversion recovery image. (author)

  11. Abnormalities on diffusion-weighted magnetic resonance imaging in patients with transient ischemic attack

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Tomomi; Shibagaki, Yasuro [Ushiku Aiwa General Hospital, Ibaraki (Japan); Uchiyama, Shinichiro; Iwata, Makoto [Tokyo Women' s Medical Coll. (Japan)

    2003-03-01

    We studied abnormalities on diffusion-weighted magnetic resonance imaging (DWI) in patients with transient ischemic attack (TIA). Out of 18 consecutive TIA patients, 9 patients had relevant focal abnormalities on DWI. Among TIA patients, six patients were associated with atrial fibrillation (Af), and all of these patients had focal abnormalities on DWI as well. TIA patients with Af had significantly more frequent focal abnormalities on DWI than those without Af (p=0.009; Fisher's exact probability test). In addition, the duration of TIA symptoms was not related to the presence of focal abnormalities on DWI. These results indicate that embolic mechanism may cause focal abnormalities on DWI. DWI was more sensitive to detect responsible ischemic lesions in these patients than T2-weighted image or fluid-attenuated inversion recovery image. (author)

  12. Prospective comparison of magnetic resonance imaging to transient elastography and serum markers for liver fibrosis detection.

    Science.gov (United States)

    Dyvorne, Hadrien A; Jajamovich, Guido H; Bane, Octavia; Fiel, M Isabel; Chou, Hsin; Schiano, Thomas D; Dieterich, Douglas; Babb, James S; Friedman, Scott L; Taouli, Bachir

    2016-05-01

    Establishing accurate non-invasive methods of liver fibrosis quantification remains a major unmet need. Here, we assessed the diagnostic value of a multiparametric magnetic resonance imaging (MRI) protocol including diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE)-MRI and magnetic resonance elastography (MRE) in comparison with transient elastography (TE) and blood tests [including ELF (Enhanced Liver Fibrosis) and APRI] for liver fibrosis detection. In this single centre cross-sectional study, we prospectively enrolled 60 subjects with liver disease who underwent multiparametric MRI (DWI, DCE-MRI and MRE), TE and blood tests. Correlation was assessed between non-invasive modalities and histopathologic findings including stage, grade and collagen content, while accounting for covariates such as age, sex, BMI, HCV status and MRI-derived fat and iron content. ROC curve analysis evaluated the performance of each technique for detection of moderate-to-advanced liver fibrosis (F2-F4) and advanced fibrosis (F3-F4). Magnetic resonance elastography provided the strongest correlation with fibrosis stage (r = 0.66, P fibrosis (F2-F4), AUCs were 0.78, 0.82, 0.72, 0.79, 0.71 for MRE, TE, DCE-MRI, DWI and APRI, respectively. For detection of advanced fibrosis (F3-F4), AUCs were 0.94, 0.77, 0.79, 0.79 and 0.70, respectively. Magnetic resonance elastography provides the highest correlation with histopathologic markers and yields high diagnostic performance for detection of advanced liver fibrosis and cirrhosis, compared to DWI, DCE-MRI, TE and serum markers. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Hybrid finite difference/finite element solution method development for non-linear superconducting magnet and electrical circuit breakdown transient analysis

    International Nuclear Information System (INIS)

    Kraus, H.G.; Jones, J.L.

    1986-01-01

    The problem of non-linear superconducting magnet and electrical protection circuit system transients is formulated. To enable studying the effects of coil normalization transients, coil distortion (due to imbalanced magnetic forces), internal coil arcs and shorts, and other normal and off-normal circuit element responses, the following capabilities are included: temporal, voltage and current-dependent voltage sources, current sources, resistors, capacitors and inductors. The concept of self-mutual inductance, and the form of the associated inductance matrix, is discussed for internally shorted coils. This is a Kirchhoff's voltage loop law and Kirchhoff's current node law formulation. The non-linear integrodifferential equation set is solved via a unique hybrid finite difference/integral finite element technique. (author)

  14. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, M.; Sakamoto, S.; Ishii, K. [Division of Neuroimaging Research, Hyogo Institute for Aging Brain and Cognitive Disorders (Japan); Imamura, T.; Kazui, H.; Mori, E. [Division of Clinical Neurosciences, Hyogo Institute for Aging Brain and Cognitive Disorders, Hyogo (Japan)

    2002-03-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  15. Transient global amnesia: increased signal intensity in the right hippocampus on diffusion-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Matsui, M.; Sakamoto, S.; Ishii, K.; Imamura, T.; Kazui, H.; Mori, E.

    2002-01-01

    We report on a patient with pure transient global amnesia (TGA) whose magnetic resonance imaging (MRI) demonstrated a small region of increased signal intensity in the right hippocampus on diffusion-weighted imaging (DWI). DWI was sensitive and useful for evaluating the early stage of TGA and might help to explain the pathophysiology of TGA. (orig.)

  16. The Grenoble station for producing strong transient magnetic fields higher than 100 teslas by an explosive driven flux compression

    International Nuclear Information System (INIS)

    Guillot, M.

    1976-01-01

    Reproducible transient magnetic fields up to 400 teslas (4 megaoersted) are achieved by a simple explosive driven flux compression. The results are described simply from the point of view of energy conversion. The problems of field measurements are studied: the precision is +-2% with a field cavity of 5 mm diameter [fr

  17. Verification and Validation of a Coordinate Transformation Method in Axisymmetric Transient Magnetics.

    Energy Technology Data Exchange (ETDEWEB)

    Ashcraft, C. Chace [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Niederhaus, John Henry [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Robinson, Allen C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-29

    We present a verification and validation analysis of a coordinate-transformation-based numerical solution method for the two-dimensional axisymmetric magnetic diffusion equation, implemented in the finite-element simulation code ALEGRA. The transformation, suggested by Melissen and Simkin, yields an equation set perfectly suited for linear finite elements and for problems with large jumps in material conductivity near the axis. The verification analysis examines transient magnetic diffusion in a rod or wire in a very low conductivity background by first deriving an approximate analytic solution using perturbation theory. This approach for generating a reference solution is shown to be not fully satisfactory. A specialized approach for manufacturing an exact solution is then used to demonstrate second-order convergence under spatial refinement and tem- poral refinement. For this new implementation, a significant improvement relative to previously available formulations is observed. Benefits in accuracy for computed current density and Joule heating are also demonstrated. The validation analysis examines the circuit-driven explosion of a copper wire using resistive magnetohydrodynamics modeling, in comparison to experimental tests. The new implementation matches the accuracy of the existing formulation, with both formulations capturing the experimental burst time and action to within approximately 2%.

  18. Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zevenhoven, Koos C. J.; Ilmoniemi, Risto J.; Dong, Hui; Clarke, John

    2015-01-01

    Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents

  19. Transcranial magnetic stimulation-induced global propagation of transient phase resetting associated with directional information flow

    Directory of Open Access Journals (Sweden)

    Masahiro eKawasaki

    2014-03-01

    Full Text Available Electroencephalogram (EEG phase synchronization analyses can reveal large-scale communication between distant brain areas. However, it is not possible to identify the directional information flow between distant areas using conventional phase synchronization analyses. In the present study, we applied transcranial magnetic stimulation (TMS to the occipital area in subjects who were resting with their eyes closed, and analyzed the spatial propagation of transient TMS-induced phase resetting by using the transfer entropy (TE, to quantify the causal and directional flow of information. The time-frequency EEG analysis indicated that the theta (5 Hz phase locking factor (PLF reached its highest value at the distant area (the motor area in this study, with a time lag that followed the peak of the transient PLF enhancements of the TMS-targeted area at the TMS onset. PPI (phase-preservation index analyses demonstrated significant phase resetting at the TMS-targeted area and distant area. Moreover, the TE from the TMS-targeted area to the distant area increased clearly during the delay that followed TMS onset. Interestingly, the time lags were almost coincident between the PLF and TE results (152 vs. 165 ms, which provides strong evidence that the emergence of the delayed PLF reflects the causal information flow. Such tendencies were observed only in the higher-intensity TMS condition, and not in the lower-intensity or sham TMS conditions. Thus, TMS may manipulate large-scale causal relationships between brain areas in an intensity-dependent manner. We demonstrated that single-pulse TMS modulated global phase dynamics and directional information flow among synchronized brain networks. Therefore, our results suggest that single-pulse TMS can manipulate both incoming and outgoing information in the TMS-targeted area associated with functional changes.

  20. Experimental investigation of transient thermoelastic effects in dynamic fracture

    International Nuclear Information System (INIS)

    Rittel, D.

    1997-01-01

    Thermoelastic effects in fracture are generally considered to be negligible at the benefit of the conversion of plastic work into heat. For the case of dynamic crack initiation, the experimental and theoretical emphasis has been put on the temperature rise associated with crack-tip plasticity. Nevertheless, earlier experimental work with polymers has shown that thermoelastic cooling precedes the temperature rise at the tip of a propagating crack (Fuller et al., 1975). Transient thermoelastic effects at the tip of a dynamically loaded crack have been theoretically assessed and shown to be significant when thermal conductivity is initially neglected. However, the fundamental question of the relation between crack initiation and thermal fields, both of transient nature, is still open. In this paper, we present an experimental investigation of the thermoelastic effect at the tip of fatigue cracks subjected to mixed-mode (dominant mode 1) dynamic loading. The material is commercial polymethylmethacrylate as an example of 'brittle' material. The applied loads, crack-tip temperatures and fracture time are simultaneously monitored to provide a more complete image of dynamic crack initiation. The corresponding evolution of the stress intensity factors is calculated by a hybrid-experimental numerical model. The results show that substantial crack-tip cooling develops initially to an extent which corroborates theoretical estimates. This effect is followed by a temperature rise. Fracture is shown to initiate during the early cooling phase, thus emphasizing the relevance of the phenomenon to dynamic crack initiation in this material as probably in other materials. (author)

  1. Modeling and analysis of biomagnetic blood Carreau fluid flow through a stenosis artery with magnetic heat transfer: A transient study.

    Science.gov (United States)

    Abdollahzadeh Jamalabadi, Mohammad Yaghoub; Daqiqshirazi, Mohammadreza; Nasiri, Hossein; Safaei, Mohammad Reza; Nguyen, Truong Khang

    2018-01-01

    We present a numerical investigation of tapered arteries that addresses the transient simulation of non-Newtonian bio-magnetic fluid dynamics (BFD) of blood through a stenosis artery in the presence of a transverse magnetic field. The current model is consistent with ferro-hydrodynamic (FHD) and magneto-hydrodynamic (MHD) principles. In the present work, blood in small arteries is analyzed using the Carreau-Yasuda model. The arterial wall is assumed to be fixed with cosine geometry for the stenosis. A parametric study was conducted to reveal the effects of the stenosis intensity and the Hartman number on a wide range of flow parameters, such as the flow velocity, temperature, and wall shear stress. Current findings are in a good agreement with recent findings in previous research studies. The results show that wall temperature control can keep the blood in its ideal blood temperature range (below 40°C) and that a severe pressure drop occurs for blockages of more than 60 percent. Additionally, with an increase in the Ha number, a velocity drop in the blood vessel is experienced.

  2. Supersonic transient magnetic resonance elastography for quantitative assessment of tissue elasticity.

    Science.gov (United States)

    Liu, Yu; Liu, Jingfei; Fite, Brett Z; Foiret, Josquin; Ilovitsh, Asaf; Leach, J Kent; Dumont, Erik; Caskey, Charles F; Ferrara, Katherine W

    2017-05-21

    Non-invasive, quantitative methods to assess the properties of biological tissues are needed for many therapeutic and tissue engineering applications. Magnetic resonance elastography (MRE) has historically relied on external vibration to generate periodic shear waves. In order to focally assess a biomaterial or to monitor the response to ablative therapy, the interrogation of a specific region of interest by a focused beam is desirable and transient MRE (t-MRE) techniques have previously been developed to accomplish this goal. Also, strategies employing a series of discrete ultrasound pulses directed to increasing depths along a single line-of-sight have been designed to generate a quasi-planar shear wave. Such 'supersonic' excitations have been applied for ultrasound elasticity measurements. The resulting shear wave is higher in amplitude than that generated from a single excitation and the properties of the media are simply visualized and quantified due to the quasi-planar wave geometry and the opportunity to generate the wave at the site of interest. Here for the first time, we extend the application of supersonic methods by developing a protocol for supersonic transient magnetic resonance elastography (sst-MRE) using an MR-guided focused ultrasound system capable of therapeutic ablation. We apply the new protocol to quantify tissue elasticity in vitro using biologically-relevant inclusions and tissue-mimicking phantoms, compare the results with elasticity maps acquired with ultrasound shear wave elasticity imaging (US-SWEI), and validate both methods with mechanical testing. We found that a modified time-of-flight (TOF) method efficiently quantified shear modulus from sst-MRE data, and both the TOF and local inversion methods result in similar maps based on US-SWEI. With a three-pulse excitation, the proposed sst-MRE protocol was capable of visualizing quasi-planar shear waves propagating away from the excitation location and detecting differences in shear

  3. Supersonic transient magnetic resonance elastography for quantitative assessment of tissue elasticity

    Science.gov (United States)

    Liu, Yu; Liu, Jingfei; Fite, Brett Z.; Foiret, Josquin; Ilovitsh, Asaf; Leach, J. Kent; Dumont, Erik; Caskey, Charles F.; Ferrara, Katherine W.

    2017-05-01

    Non-invasive, quantitative methods to assess the properties of biological tissues are needed for many therapeutic and tissue engineering applications. Magnetic resonance elastography (MRE) has historically relied on external vibration to generate periodic shear waves. In order to focally assess a biomaterial or to monitor the response to ablative therapy, the interrogation of a specific region of interest by a focused beam is desirable and transient MRE (t-MRE) techniques have previously been developed to accomplish this goal. Also, strategies employing a series of discrete ultrasound pulses directed to increasing depths along a single line-of-sight have been designed to generate a quasi-planar shear wave. Such ‘supersonic’ excitations have been applied for ultrasound elasticity measurements. The resulting shear wave is higher in amplitude than that generated from a single excitation and the properties of the media are simply visualized and quantified due to the quasi-planar wave geometry and the opportunity to generate the wave at the site of interest. Here for the first time, we extend the application of supersonic methods by developing a protocol for supersonic transient magnetic resonance elastography (sst-MRE) using an MR-guided focused ultrasound system capable of therapeutic ablation. We apply the new protocol to quantify tissue elasticity in vitro using biologically-relevant inclusions and tissue-mimicking phantoms, compare the results with elasticity maps acquired with ultrasound shear wave elasticity imaging (US-SWEI), and validate both methods with mechanical testing. We found that a modified time-of-flight (TOF) method efficiently quantified shear modulus from sst-MRE data, and both the TOF and local inversion methods result in similar maps based on US-SWEI. With a three-pulse excitation, the proposed sst-MRE protocol was capable of visualizing quasi-planar shear waves propagating away from the excitation location and detecting differences in shear

  4. Nernst Effect in Magnetized Plasmas

    OpenAIRE

    Joglekar, Archis S.; Thomas, Alexander G. R.; Ridgers, Christopher P.; Kingham, Robert J.

    2015-01-01

    We present nanosecond timescale Vlasov-Fokker-Planck-Maxwell modeling of magnetized plasma transport and dynamics in a hohlraum with an applied external magnetic field, under conditions similar to recent experiments. Self-consistent modeling of the kinetic electron momentum equation allows for a complete treatment of the heat flow equation and Ohm's Law, including Nernst advection of magnetic fields. In addition to showing the prevalence of non-local behavior, we demonstrate that effects such...

  5. Effective magnetic moment of neutrinos in strong magnetic fields

    International Nuclear Information System (INIS)

    Perez M, A.; Perez R, H.; Masood, S.S.; Gaitan, R.; Rodriguez R, S.

    2002-01-01

    In this paper we compute the effective magnetic moment of neutrinos propagating in dense high magnetized medium. Taking typical values of magnetic field and densities of astrophysical objects (such as the cores of supernovae and neutron stars) we obtain an effective type of dipole magnetic moment in agreement with astrophysical and cosmological bounds. (Author)

  6. A semi-quantitative study of transient ischemic attacks by diffusion weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    Wen Feng; Guo Liang

    2007-01-01

    Objective: To explore the incidence and morphological findings of transient ischemic attacks (TIA) related-focus by diffusion weighted magnetic resonance imaging(DWI), and the semi-quantitative characteristics of TIA related-focus on DWI manifestation were researched. Methods: A prospective analysis was performed on 39 TIA patients who were admitted to the Pudong New Area People Hospital and who had also undergone DWI scan 3 , and rADC ratio of the lesion was (-25.8 ± 9.01)%, and rAI ratio was(59.9 ± 12.9)% and compared with that of the contralateral side there was significant difference. Conclusion: The incidence of positivity rate of DWI is more than that obtained by conventional MR imaging. The related focus of TIA are very small and the ADC value of the lesion is decreased slightly, but averge intensity is increased highly. These data may be of value in identifying those TIA patients for whom MRI evaluation with DWI is of great clinical utility. (authors)

  7. Sequential changes in ischemic edema following transient focal cerebral ischemia in rats; Magnetic resonance imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Nagahiro, Shinji; Goto, Satoshi; Kogo, Kasei; Sumi, Minako; Takahashi, Mutsumasa; Ushio, Yukitaka [Kumamoto Univ. (Japan). School of Medicine

    1994-07-01

    Sequential and regional changes in ischemic edema following various durations of focal cerebral ischemia were studied by magnetic resonance (MR) imaging in a rat unilateral intraluminal middle cerebral artery occlusion model. Occlusion was performed from 5 minutes to 5 hours. T[sub 2]-weighted images were obtained chronologically 6 hours after onset of ischemia, on day 1 and day 7. An immunohistochemical study using antibodies to calcineurin and glial fibrillary acidic protein was performed to observe histological changes in the ischemic brain. The T[sub 2] high-signal-intensity areas representing ischemic edema were observed in the lateral striatum and/or the cerebral cortex by day 1 in all rats with 1- to 5-hour ischemia, and the areas were larger and detected earlier with longer durations of ischemia. In three of six rats with 15-minute ischemia and five of six rats with 30-minute ischemia, the T[sub 2] high-signal-intensity areas appeared transiently on day 1 in the dorsolateral striatum where loss of neurons expressing calcineurin immunoreactivity and associated gliosis were found. MR imaging in animal models of reversible focal ischemia can achieve sequential and noninvasive evaluation of dynamic regional changes in ischemic edema. (author).

  8. Magnetic resonance imaging and transient elastography in the management of Nonalcoholic Fatty Liver Disease (NAFLD).

    Science.gov (United States)

    Han, Ma Ai Thanda; Saouaf, Rola; Ayoub, Walid; Todo, Tsuyoshi; Mena, Edward; Noureddin, Mazen

    2017-04-01

    Nonalcoholic fatty liver disease (NAFLD) is the most common cause of chronic liver disease and cirrhosis worldwide and the second most common cause of liver transplantation in major medical centers. Because liver steatosis and fibrosis severity are related to disease morbidity and mortality, the extent of disease, and disease progression, they need to be assessed and monitored. In addition, innovation with new drug developments requires disease staging and monitoring in both phase 2 and 3 clinical trials. Currently, disease assessment in both clinical practice and research is mostly performed by liver biopsy, an invasive, procedure with risks. Noninvasive, highly accurate tests are needed that could be used in clinical trials as surrogate endpoints and in clinical practice for monitoring patients. Area Covered: We discuss noninvasive tests, transient elastography (TE) with controlled attenuation parameter (CAP), magnetic resonance imaging (MRI), and MR elastography (MRE), summarize the available evidence of their usefulness for assessing steatosis and fibrosis. Therefore they could be used as clinical trials outcomes and in disease monitoring in clinical practice. Expert Commentary: TE with CAP, MRI and MRE are highly accurate noninvasive diagnostic tools for quantifying hepatic steatosis and fibrosis. Therefore they could be used as clinical trials outcomes and in disease monitoring in clinical practice.

  9. Mere exposure effect can be elicited in transient global amnesia.

    Science.gov (United States)

    Marin-Garcia, Eugenia; Ruiz-Vargas, Jose M; Kapur, Narinder

    2013-01-01

    Transient global amnesia (TGA) is one of the most severe forms of anterograde amnesia seen in clinical practice, yet patients may show evidence of spared learning during the amnesic episode. The scope of spared learning in such a severe form of amnesia remains uncertain, and it is also unclear whether findings from single-case studies hold up in group studies of TGA patients. In this group study, we found evidence that extended the domain of spared learning in TGA to include the mere exposure effect, whereby enhanced preference is primed by prior exposure to stimuli. We demonstrate this effect during an acute episode in a group of TGA patients, where they showed enhanced preference for previously exposed faces, despite markedly impaired performance on standard anterograde memory tests.

  10. Study of axial magnetic effect

    Energy Technology Data Exchange (ETDEWEB)

    Braguta, Victor [IHEP, Protvino, Moscow region, 142284 Russia ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 (Russian Federation); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Chernodub, M. N. [CNRS, Laboratoire de Mathématiques et Physique Théorique, Université François-Rabelais Tours, Fédération Denis Poisson, Parc de Grandmont, 37200 Tours, France Department of Physics and Astronomy, University of Gent, Krijgslaan 281, S9, B-9000 Gent (Belgium); School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Goy, V. A. [School of Natural Sciences, Far Eastern Federal University, Sukhanova street 8, Vladivostok, 690950 (Russian Federation); Landsteiner, K. [Instituto de Física Teórica UAM/CSIC, C/ Nicolás Cabrera 13-15, Universidad Autónoma de Madrid, Cantoblanco, 28049 Madrid (Spain); Molochkov, A. V. [School of Biomedicine, Far Eastern Federal University, Ajax 10 Building 25, Russian island, Vladivostok, 690922 (Russian Federation); Ulybyshev, M. [ITEP, B. Cheremushkinskaya street 25, Moscow, 117218 Russia Institute for Theoretical Problems of Microphysics, Moscow State University, Moscow, 119899 (Russian Federation)

    2016-01-22

    The Axial Magnetic Effect manifests itself as an equilibrium energy flow of massless fermions induced by the axial (chiral) magnetic field. Here we study the Axial Magnetic Effect in the quenched SU(2) lattice gauge theory with massless overlap fermions at finite temperature. We numerically observe that in the low-temperature hadron phase the effect is absent due to the quark confinement. In the high-temperature deconfinement phase the energy flow is an increasing function of the temperature which reaches the predicted asymptotic T{sup 2} behavior at high temperatures. We find, however, that energy flow is about one order of magnitude lower compared to a theoretical prediction.

  11. Effect of magnet/slot combination on triple-frequency magnetic force and vibration of permanent magnet motors

    Science.gov (United States)

    Huo, Mina; Wang, Shiyu; Xiu, Jie; Cao, Shuqian

    2013-10-01

    The relationship between magnet/slot combination and magnetic forces including unbalanced magnetic force (UMF) and cogging torque (CT) of permanent magnet (PM) motors is investigated by using superposition principle and mechanical and magnetic symmetries. The results show that magnetic force can be produced by all magnets passing a single slot, by all slots passing a single magnet, or by eccentricity, which respectively correspond to three frequency components. The results further show that net force/torque can be classified into three typical cases: UMF is suppressed and CT is excited, UMF excited and CT suppressed, and UMF and CT both suppressed, and consequently possible vibrations include three unique groups: rotational modes, translational modes, and balanced modes. The conclusion that combinations with the greatest common divisor (GCD) greater than unity can avoid UMF is mathematically verified, and at the same time lower CT harmonics are preliminarily addressed by the typical excitations. The above findings can create simple guidelines for the suppression of certain UMF and/or CT by using suitable combinations, which in turn can present approach to yield a more desirable response in high performance applications. The superposition effect and predicted relationship are verified by the transient magnetic Finite Element method. Since this work is motivated by symmetries, comparisons are made in order to give further insight into the inner force and vibration behaviors of general rotary power-transmission systems.

  12. Analysis of Unbalanced Magnetic Pull in Wound Rotor Induction Machines using Finite Element Analysis – Transient, Motoring and Generating Modes

    DEFF Research Database (Denmark)

    Dorrell, David G.; Hermann, Alexander Niels August; Jensen, Bogi Bech

    2013-01-01

    eccentricity. The operating conditions are varied so that transient, motoring and doubly-fed induction generator modes are studied. This allows greater understanding of the radial forces involved. Wound rotor induction machines exhibit higher unbalanced magnetic pull than cage induction machines so......There has been much literature on unbalanced magnetic pull in various types of electrical machine. This can lead to bearing wear and additional vibrations in the machine. In this paper a wound rotor induction is studied. Finite element analysis studies are conducted when the rotor has 10 % rotor...

  13. Kinematics analysis of vertical magnetic suspension energy storage flywheel rotor under transient rotational speed

    Science.gov (United States)

    Ren, Zhengyi; Huang, Tong; Feng, Jiajia; Zhou, Yuanwei

    2018-05-01

    In this paper, a 600Wh vertical maglev energy storage flywheel rotor system is taken as a model. The motion equation of a rigid rotor considering the gyroscopic effect and the center of mass offset is obtained by the centroid theorem, and the experimental verification is carried out. Using the state variable method, the Matlab software was used to program and simulate the radial displacement and radial electromagnetic force of the rotor system at each speed. The results show that the established system model is in accordance with the designed 600Wh vertical maglev energy storage flywheel model. The results of the simulation analysis are helpful to further understand the dynamic nature of the flywheel rotor at different transient speeds.

  14. Transient magnetoviscosity of dilute ferrofluids

    International Nuclear Information System (INIS)

    Soto-Aquino, Denisse; Rinaldi, Carlos

    2011-01-01

    The magnetic field induced change in the viscosity of a ferrofluid, commonly known as the magnetoviscous effect and parameterized through the magnetoviscosity, is one of the most interesting and practically relevant aspects of ferrofluid phenomena. Although the steady state behavior of ferrofluids under conditions of applied constant magnetic fields has received considerable attention, comparatively little attention has been given to the transient response of the magnetoviscosity to changes in the applied magnetic field or rate of shear deformation. Such transient response can provide further insight into the dynamics of ferrofluids and find practical application in the design of devices that take advantage of the magnetoviscous effect and inevitably must deal with changes in the applied magnetic field and deformation. In this contribution Brownian dynamics simulations and a simple model based on the ferrohydrodynamics equations are applied to explore the dependence of the transient magnetoviscosity for two cases: (I) a ferrofluid in a constant shear flow wherein the magnetic field is suddenly turned on, and (II) a ferrofluid in a constant magnetic field wherein the shear flow is suddenly started. Both simulations and analysis show that the transient approach to a steady state magnetoviscosity can be either monotonic or oscillatory depending on the relative magnitudes of the applied magnetic field and shear rate. - Research Highlights: →Rotational Brownian dynamics simulations were used to study the transient behavior of the magnetoviscosity of ferrofluids. →Damped and oscillatory approach to steady state magnetoviscosity was observed for step changes in shear rate and magnetic field. →A model based on the ferrohydrodynamics equations qualitatively captured the damped and oscillatory features of the transient response →The transient behavior is due to the interplay of hydrodynamic, magnetic, and Brownian torques on the suspended particles.

  15. User effects on the transient system code calculations. Final report

    International Nuclear Information System (INIS)

    Aksan, S.N.; D'Auria, F.

    1995-01-01

    Large thermal-hydraulic system codes are widely used to perform safety and licensing analyses of nuclear power plants to optimize operational procedures and the plant design itself. Evaluation of the capabilities of these codes are accomplished by comparing the code predictions with the measured experimental data obtained from various types of separate effects and integral test facilities. In recent years, some attempts have been made to establish methodologies to evaluate the accuracy and the uncertainty of the code predictions and consequently judgement on the acceptability of the codes. In none of the methodologies has the influence of the code user on the calculated results been directly addressed. In this paper, the results of the investigations on the user effects for the thermal-hydraulic transient system codes is presented and discussed on the basis of some case studies. The general findings of the investigations show that in addition to user effects, there are other reasons that affect the results of the calculations and which are hidden under user effects. Both the hidden factors and the direct user effects are discussed in detail and general recommendations and conclusions are presented to control and limit them

  16. Transient electromagnetic and dynamic structural analyses of a blanket structure with coupling effects

    Energy Technology Data Exchange (ETDEWEB)

    Koganezawa, K. [Mitsubishi Atomic Power Industries, Inc., Yokohama (Japan); Kushiyama, M. [Mitsubishi Atomic Power Industries, Inc., Yokohama (Japan); Niikura, S. [Mitsubishi Atomic Power Industries, Inc., Yokohama (Japan); Kudough, F. [Mitsubishi Atomic Power Industries, Inc., Yokohama (Japan); Onozuka, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Koizumi, K. [Japan Atomic Energy Research Inst., Ibaraki (Japan)

    1995-12-31

    Transient electromagnetic and dynamic structural analyses of a blanket structure in the fusion experimental reactor (FER) under a plasma disruption event and a vertical displacement event (VDE) have been performed to investigate the dynamic structural characteristics and the feasibility of the structure. Coupling effects between eddy currents and dynamic deflections have also been taken into account in these analyses. In this study, the inboard blanket was employed because of our computer memory limitation. A 1/192 segment model of a full torus was analyzed using the analytical code, EDDYCUFF. In the plasma disruption event, the maximum magnetic pressure caused by eddy currents and poloidal fields was 1.2MPa. The maximum stress intensity by this magnetic pressure was 114MPa. In the VDE, the maximum magnetic pressure was 2.4MPa and the maximum stress intensity was 253MPa. This stress was somewhat beyond the allowable stress limit. Therefore, the blanket structure and support design should be reviewed to reduce the stress to a suitable value. In summary, the dynamic structural characteristics and design issues of the blanket structure have been identified. (orig.).

  17. Magnetic effects in anomalous dispersion

    International Nuclear Information System (INIS)

    Blume, M.

    1992-01-01

    Spectacular enhancements of magnetic x-ray scattering have been predicted and observed experimentally. These effects are the result of resonant phenomena closely related to anomalous dispersion, and they are strongest at near-edge resonances. The theory of these resonances will be developed with particular attention to the symmetry properties of the scatterer. While the phenomena to be discussed concern magnetic properties the transitions are electric dipole or electric quadrupole in character and represent a subset of the usual anomalous dispersion phenomena. The polarization dependence of the scattering is also considered, and the polarization dependence for magnetic effects is related to that for charge scattering and to Templeton type anisotropic polarization phenomena. It has been found that the strongest effects occur in rare-earths and in actinides for M shell edges. In addition to the scattering properties the theory is applicable to ''forward scattering'' properties such as the Faraday effect and circular dichroism

  18. Effects of transient conditions on exhaust emissions from two non-road diesel engines

    International Nuclear Information System (INIS)

    Lindgren, M.; Hansson, P.-A.

    2004-01-01

    Growing interest in quantifying and reducing the amount of engine emissions of carbon monoxide, hydrocarbons, and nitrogen oxides loading the environment has led to increasingly tighter environmental regulations. However, current non-road emission standards are performed according to a steady-state test cycle, which does not include transient effects and thus underestimates the amount of emissions produced in real use of the engine. This study quantifies the effects of transients in engine speed and torque on the fuel consumption and emissions from two diesel engines intended for non-road mobile machinery. Fuel consumption and emissions from the engines were measured in an engine dynamometer during various transient load conditions. The results showed that during fast transients, the measured fuel consumption was up to twice as high as the corresponding steady-state load conditions. The effects of transients on emissions of nitrogen oxides were even greater, as were the effects of transient load increase with increasing transient conditions i. e. rate of change. The results showed that the effect of transients on fuel consumption and emissions were also dependent on the type of diesel injection pump and the engine equipment used. Furthermore, the results indicated that the air/fuel ratio was an important contributor to the emission formation process during transient loads. (Author)

  19. Effect of transmitter turn-off time on transient soundings

    Science.gov (United States)

    Fitterman, D.V.; Anderson, W.L.

    1987-01-01

    A general procedure for computing the effect of non-zero turn-off time on the transient electromagnetic response is presented which can be applied to forward and inverse calculation methods for any transmitter-receiver configuration. We consider in detail the case of a large transmitter loop which has a receiver coil located at the center of the loop (central induction or in-loop array). For a linear turn-off ramp of width t0, the voltage response is shown to be the voltage due to an ideal step turn-off averaged over windows of width t0. Thus the effect is similar to that obtained by using averaging windows in the receiver. In general when time zero is taken to be the end of the ramp, the apparent resistivity increases for a homogeneous half-space over a limited time range. For time zero taken to be the start of the ramp the apparent resistivity is affected in the opposite direction. The effect of the ramp increases with increasing t0 and first-layer resistivity, is largest during the intermediate stage, and decreases with increasing time. It is shown that for a ramp turn-off, there is no effect in the early and late stages. For two-layered models with a resistive first layer (??1>??2), the apparent resistivity is increased in the intermediate stage. When the first layer is more conductive than the second layer (??1interpretation as shown by field examples; the influence is the greatest on near-surface layer parameters. ?? 1987.

  20. Effects of electrode geometry on transient plasma induced ignition

    International Nuclear Information System (INIS)

    Shukla, B; Gururajan, V; Eisazadeh-Far, K; Windom, B; Egolfopoulos, F N; Singleton, D; Gundersen, M A

    2013-01-01

    Achieving effective ignition of reacting mixtures using nanosecond pulsed discharge non-equilibrium transient plasma (TP), requires that the effects of several experimental parameters be quantified and understood. Among them are the electrode geometry, the discharge location especially in non-premixed systems, and the relative ignition performance by spark and TP under the same experimental conditions. In the present investigation, such issues were addressed experimentally using a cylindrical constant volume combustion chamber and a counterflow flame configuration coupled with optical shadowgraph that enables observation of how and where the ignition process starts. Results were obtained under atmospheric pressure and showed that the electrode geometry has a notable influence on ignition, with the needle-to-semicircle exhibiting the best ignition performance. Furthermore, it was determined that under non-premixed conditions discharging TP in the reactants mixing layer was most effective in achieving ignition. It was also determined that in the cases considered, the TP induced ignition initiates from the needle head where the electric field and electron densities are the highest. In the case of a spark, however, ignition was found to initiate always from the hot region between the two electrodes. Comparison of spark and TP discharges in only air (i.e. without fuel) and ignition phenomena induced by them also suggest that in the case of TP ignition is at least partly non-thermal and instead driven by the production of active species. Finally, it was determined that single pulsed TP discharges are sufficient to ignite both premixed and non-premixed flames of a variety of fuels ranging from hydrogen to heavy fuels including F-76 diesel and IFO380 bunker fuel even at room temperature. (paper)

  1. Exposure to power frequency magnetic fields suppresses X-ray-induced apoptosis transiently in Ku80-deficient xrs5 cells

    International Nuclear Information System (INIS)

    Tian, Furong; Nakahara, Takehisa; Yoshida, Masami; Honda, Naoko; Hirose, Hideki; Miyakoshi, Junji

    2002-01-01

    In an attempt to determine whether exposure to extremely low frequency (ELF) electromagnetic fields can affect cells, Ku80-deficient cells (xrs5) and Ku80-proficient cells (CHO-K1) were exposed to ELF electromagnetic fields. Cell survival, and the levels of the apoptosis-related genes p21, p53, phospho-p53 (Ser 15 ), caspase-3 and the anti-apoptosis gene bcl-2 were determined in xrs5 and CHO-K1 cells following exposure to ELF electromagnetic fields and X-rays. It was found that exposure of xrs5 and CHO-K1 cells to 60 Hz ELF electromagnetic fields had no effect on cell survival, cell cycle distribution and protein expression. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields for 5 h after irradiation significantly inhibited G 1 cell cycle arrest induced by X-rays (1 Gy) and resulted in elevated bcl-2 expression. A significant decrease in the induction of p53, phospho-p53, caspase-3 and p21 proteins was observed in xrs5 cells when irradiation by X-rays (8 Gy) was followed by exposure to 5 mT ELF magnetic fields. Exposure of xrs5 cells to the ELF electromagnetic fields for 10 h following irradiation significantly decreased X-ray-induced apoptosis from about 1.7% to 0.7%. However, this effect was not found in CHO-K1 cells within 24 h of irradiation by X-rays alone and by X-rays combined with ELF electromagnetic fields. Exposure of xrs5 cells to 60 Hz ELF electromagnetic fields following irradiation can affect cell cycle distribution and transiently suppress apoptosis by decreasing the levels of caspase-3, p21, p53 and phospho-p53 and by increasing bcl-2 expression

  2. Cognitive Load Theory and the Effects of Transient Information on the Modality Effect

    Science.gov (United States)

    Leahy, Wayne; Sweller, John

    2016-01-01

    Based on cognitive load theory and the "transient information effect," this paper investigated the "modality effect" while interpreting a contour map. The length and complexity of auditory and visual text instructions were manipulated. Experiment 1 indicated that longer audio text information within a presentation was inferior…

  3. Transient Splenial Lesion of Corpus Callosum Associated with Antiepileptic Drug: Conventional and Diffusion-weighted Magnetic Resonance Images

    Energy Technology Data Exchange (ETDEWEB)

    Hakyemez, B.; Erdogan, C.; Yildirim, N.; Gokalp, G.; Parlak, M. [Uludag Univ. Medical School, Bursa (Turkey). Dept. of Radiology

    2005-11-01

    Transient focal lesions of splenium of corpus callosum can be seen as a component of many central nervous system diseases, including antiepileptic drug toxicity. The conventional magnetic resonance (MR) findings of the disease are characteristic and include ovoid lesions with high signal intensity at T2-weighted MRI. Limited information exists about the diffusion-weighted MRI characteristics of these lesions vanishing completely after a period of time. We examined the conventional, FLAIR, and diffusion-weighted MR images of a patient complaining of depressive mood and anxiety disorder after 1 year receiving antiepileptic medication.

  4. A High-Performance Portable Transient Electro-Magnetic Sensor for Unexploded Ordnance Detection

    Directory of Open Access Journals (Sweden)

    Haofeng Wang

    2017-11-01

    Full Text Available Portable transient electromagnetic (TEM systems can be well adapted to various terrains, including mountainous, woodland, and other complex terrains. They are widely used for the detection of unexploded ordnance (UXO. As the core component of the portable TEM system, the sensor is constructed with a transmitting coil and a receiving coil. Based on the primary field of the transmitting coil and internal noise of the receiving coil, the design and testing of such a sensor is described in detail. Results indicate that the primary field of the transmitting coil depends on the diameter, mass, and power of the coil. A higher mass–power product and a larger diameter causes a stronger primary field. Reducing the number of turns and increasing the clamp voltage reduces the switch-off time of the transmitting current effectively. Increasing the cross-section of the wire reduces the power consumption, but greatly increases the coil’s weight. The study of the receiving coil shows that the internal noise of the sensor is dominated by the thermal noise of the damping resistor. Reducing the bandwidth of the system and increasing the size of the coil reduces the internal noise effectively. The cross-sectional area and the distance between the sections of the coil have little effect on the internal noise. A less damped state can effectively reduce signal distortion. Finally, a portable TEM sensor with both a transmitting coil (constructed with a diameter, number of turns, and transmitting current of 0.5 m, 30, and 5 A, respectively and a receiving coil (constructed with a length and resonant frequency of 5.6 cm and 50 kHz, respectively was built. The agreement between experimental and calculated results confirms the theory used in the sensor design. The responses of an 82 mm mortar shell at different distances were measured and inverted by the differential evolution (DE algorithm to verify system performance. Results show that the sensor designed in this

  5. A High-Performance Portable Transient Electro-Magnetic Sensor for Unexploded Ordnance Detection.

    Science.gov (United States)

    Wang, Haofeng; Chen, Shudong; Zhang, Shuang; Yuan, Zhiwen; Zhang, Haiyang; Fang, Dong; Zhu, Jun

    2017-11-17

    Portable transient electromagnetic (TEM) systems can be well adapted to various terrains, including mountainous, woodland, and other complex terrains. They are widely used for the detection of unexploded ordnance (UXO). As the core component of the portable TEM system, the sensor is constructed with a transmitting coil and a receiving coil. Based on the primary field of the transmitting coil and internal noise of the receiving coil, the design and testing of such a sensor is described in detail. Results indicate that the primary field of the transmitting coil depends on the diameter, mass, and power of the coil. A higher mass-power product and a larger diameter causes a stronger primary field. Reducing the number of turns and increasing the clamp voltage reduces the switch-off time of the transmitting current effectively. Increasing the cross-section of the wire reduces the power consumption, but greatly increases the coil's weight. The study of the receiving coil shows that the internal noise of the sensor is dominated by the thermal noise of the damping resistor. Reducing the bandwidth of the system and increasing the size of the coil reduces the internal noise effectively. The cross-sectional area and the distance between the sections of the coil have little effect on the internal noise. A less damped state can effectively reduce signal distortion. Finally, a portable TEM sensor with both a transmitting coil (constructed with a diameter, number of turns, and transmitting current of 0.5 m, 30, and 5 A, respectively) and a receiving coil (constructed with a length and resonant frequency of 5.6 cm and 50 kHz, respectively) was built. The agreement between experimental and calculated results confirms the theory used in the sensor design. The responses of an 82 mm mortar shell at different distances were measured and inverted by the differential evolution (DE) algorithm to verify system performance. Results show that the sensor designed in this study can not only

  6. Magnetic field effects in proteins

    Science.gov (United States)

    Jones, Alex R.

    2016-06-01

    Many animals can sense the geomagnetic field, which appears to aid in behaviours such as migration. The influence of man-made magnetic fields on biology, however, is potentially more sinister, with adverse health effects being claimed from exposure to fields from mobile phones or high voltage power lines. Do these phenomena have a common, biophysical origin, and is it even plausible that such weak fields can profoundly impact noisy biological systems? Radical pair intermediates are widespread in protein reaction mechanisms, and the radical pair mechanism has risen to prominence as perhaps the most plausible means by which even very weak fields might impact biology. In this New Views article, I will discuss the literature over the past 40 years that has investigated the topic of magnetic field effects in proteins. The lack of reproducible results has cast a shadow over the area. However, magnetic field and spin effects have proven to be useful mechanistic tools for radical mechanism in biology. Moreover, if a magnetic effect on a radical pair mechanism in a protein were to influence a biological system, the conditions necessary for it to do so appear increasing unlikely to have come about by chance.

  7. Thermoelectric effects in magnetic nanostructures

    NARCIS (Netherlands)

    Hatami, Moosa; Bauer, Gerrit E.W.; Zhang, Q.F.; Kelly, Paul J.

    2009-01-01

    We model and evaluate the Peltier and Seebeck effects in magnetic multilayer nanostructures by a finite-element theory of thermoelectric properties. We present analytical expressions for the thermopower and the current-induced temperature changes due to Peltier cooling/heating. The thermopower of a

  8. Simulation of transient effects in the heavy ion fusion injectors

    International Nuclear Information System (INIS)

    Chen, Y.J.; Hewett, D.

    1993-01-01

    The authors have used the 2-D PIC code, GYMNOS, to study the transient behaviors in the Heavy Ion Fusion (HIF) injectors. GYMNOS simulations accurately provide the steady state Child-Langmuir current and the beam transient behavior within a planar diode. The simulations of the LBL HIF ESAC injector experiments agree well with the experimental data and EGUN steady state results. Simulations of the nominal HIF injectors have revealed the need to design the accelerating electrodes carefully to control the ion beam current, particularly the ion loss at the end of the bunch as the extraction voltage is reduced

  9. Simulation of transient effects in the heavy ion fusion injectors

    Science.gov (United States)

    Chen, Yu-Jiuan; Hewett, D. W.

    1993-05-01

    We have used the 2-D PIC code, GYMNOS, to study the transient behaviors in the Heavy Ion Fusion (HIF) injectors. GYMNOS simulations accurately provide the steady state Child-Langmuir current and the beam transient behavior within a planar diode. The simulations of the LBL HIF ESAC injector experiments agree well with the experimental data and EGUN steady state results. Simulations of the nominal HIF injectors have revealed the need to design the accelerating electrodes carefully to control the ion beam current, particularly the ion loss at the end of the bunch as the extraction voltage is reduced.

  10. Magnetic field effects on brain monoamine oxidase activity

    Energy Technology Data Exchange (ETDEWEB)

    Borets, V.M.; Ostrovskiy, V.Yu.; Bankovskiy, A.A.; Dudinskaya, T.F.

    1985-03-01

    In view of the increasing use of magnetotherapy, studies were conducted on the effects of 35 mTesla magnetic fields on monoamine oxidase activity in the rat brain. Under in vitro conditions a constant magnetic field in the continuous mode was most effective in inhibiting deamination of dopamine following 1 min exposure, while in vivo studies with 8 min or 10 day exposures showed that inhibition was obtained only with a variable field in the continuous mode. However, inhibition of dopamine deamination was only evident within the first 24 h after exposure was terminated. In addition, in none of the cases was norepinephrine deamination inhibited. The effects of the magnetic fields were, therefore, transient and selective with the CNS as the target system. 9 references.

  11. Magnetic field and magnetic isotope effects on photochemical reactions

    International Nuclear Information System (INIS)

    Wakasa, Masanobu

    1999-01-01

    By at present exact experiments and the theoretical analysis, it was clear that the magnetic field less than 2 T affected a radical pair reaction and biradical reaction. The radical pair life and the dissipative radical yield showed the magnetic field effects on chemical reactions. The radical pair mechanism and the triplet mechanism were known as the mechanism of magnetic field effects. The radical pair mechanism consists of four mechanisms such as the homogeneous hyperfine interaction (HFC), the delta-g mechanism, the relaxation mechanism and the level cross mechanism. In order to observe the magnetic effects of the radical pair mechanism, two conditions need, namely, the recombination rate of singlet radical pair > the dissipation rate and the spin exchange rate > the dissipation rate. A nanosecond laser photo-decomposition equipment can observe the magnetic field effects. The inversion phenomena of magnetic field effect, isolation of the relaxation mechanism and the delta-g mechanism, the magnetic field effect of heavy metal radical reaction, the magnetic field effect in homogeneous solvent, saturation of delta-g mechanism are explained. The succeeded examples of isotope concentration by the magnetic isotope effect are 17 O, 19 Si, 33 S, 73 Ge and 235 U. (S.Y.)

  12. Radiation-Induced Transient Effects in Near Infrared Focal Plane Arrays

    Science.gov (United States)

    Reed, Robert A.; Pickel, J.; Marshall, P.; Waczynski, A.; McMurray, R.; Gee, G.; Polidan, E.; Johnson, S.; McKeivey, M.; Ennico, K.; hide

    2004-01-01

    This viewgraph presentation describes a test simulate the transient effects of cosmic ray impacts on near infrared focal plane arrays. The objectives of the test are to: 1) Characterize proton single events as function of energy and angle of incidence; 2) Measure charge spread (crosstalk) to adjacent pixels; 3) Assess transient recovery time.

  13. Transient protective effect of caspase inhibitors in RCS rat.

    Science.gov (United States)

    Perche, O; Doly, M; Ranchon-Cole, I

    2008-03-01

    In most retinal degenerations in humans and in animal models, photoreceptor cells die by apoptosis. Although the biochemical features are similar in all apoptotic cells, different molecular events lead the cell to death. In the present study we used a rat model of inherited retinal degeneration, the RCS rats, to investigate the involvement of the proteases, caspases and/or calpains, in photoreceptor apoptosis. In the first experiments, rats were untreated or injected intravitreally at post natal day 27 (P27) with the large broad spectrum caspase inhibitor, ZVAD, the calpain inhibitor, MuhPhe, or with the vehicle, DMSO. Retinal status was evaluated at P35 and P42 by electroretinography, morphometry and apoptotic nuclei detection. DMSO and MuhPhe had no effect on RCS retinas as evidenced by equivalent loss of function and equivalent number of apoptotic cells than in untreated group. ZVAD transiently reduced apoptotic cells and preserved photoreceptor function at P35 but not at P42. These results suggest that caspases but not calpains are involved in retinal degeneration in the RCS. In the second experiments, RCS rats were injected twice at P27 and P35 with ZVAD or DMSO. Although ZVAD-treated retinas were preserved at P35 compared to the DMSO controls, the second injection of ZVAD did not extend the preserving effect to P42. Moreover, a single injection of ZVAD at P35 had no preserving effect at P42. All these data taken together suggest that caspases do not play a pivotal role after P35. In a fourth set of experiments, we used specific caspase inhibitors to elucidate which caspase was activated. The caspase-1/4 inhibitor (YVAD) or the caspase-3/7 inhibitor (DEVD) were injected intravitreally at P27 and retinal status was evaluated at P35 and P42. Electroretinograms and apoptotic nuclei detection demonstrated that YVAD and DEVD preserved photoreceptors at P35 but not at P42. These results suggest that both caspase-1/4 and caspase-3/7 play a major role in the apoptotic

  14. Transient optical and electrical effects in polymeric semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Bange, Sebastian

    2009-05-28

    Classical semiconductor physics has been continuously improving electronic components such as diodes, light-emitting diodes, solar cells and transistors based on highly purified inorganic crystals over the past decades. Organic semiconductors, notably polymeric, are a comparatively young field of research, the first light-emitting diode based on conjugated polymers having been demonstrated in 1990. Polymeric semiconductors are of tremendous interest for high-volume, low-cost manufacturing (''printed electronics''). Due to their rather simple device structure mostly comprising only one or two functional layers, polymeric diodes are much more difficult to optimize compared to small-molecular organic devices. Usually, functions such as charge injection and transport are handled by the same material which thus needs to be highly optimized. The present work contributes to expanding the knowledge on the physical mechanisms determining device performance by analyzing the role of charge injection and transport on device efficiency for blue and white-emitting devices, based on commercially relevant spiro-linked polyfluorene derivatives. It is shown that such polymers can act as very efficient electron conductors and that interface effects such as charge trapping play the key role in determining the overall device efficiency. This work contributes to the knowledge of how charges drift through the polymer layer to finally find neutral emissive trap states and thus allows a quantitative prediction of the emission color of multichromophoric systems, compatible with the observed color shifts upon driving voltage and temperature variation as well as with electrical conditioning effects. In a more methodically oriented part, it is demonstrated that the transient device emission observed upon terminating the driving voltage can be used to monitor the decay of geminately-bound species as well as to determine trapped charge densities. This enables direct comparisons with numerical

  15. Transient optical and electrical effects in polymeric semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Bange, Sebastian

    2009-05-28

    Classical semiconductor physics has been continuously improving electronic components such as diodes, light-emitting diodes, solar cells and transistors based on highly purified inorganic crystals over the past decades. Organic semiconductors, notably polymeric, are a comparatively young field of research, the first light-emitting diode based on conjugated polymers having been demonstrated in 1990. Polymeric semiconductors are of tremendous interest for high-volume, low-cost manufacturing (''printed electronics''). Due to their rather simple device structure mostly comprising only one or two functional layers, polymeric diodes are much more difficult to optimize compared to small-molecular organic devices. Usually, functions such as charge injection and transport are handled by the same material which thus needs to be highly optimized. The present work contributes to expanding the knowledge on the physical mechanisms determining device performance by analyzing the role of charge injection and transport on device efficiency for blue and white-emitting devices, based on commercially relevant spiro-linked polyfluorene derivatives. It is shown that such polymers can act as very efficient electron conductors and that interface effects such as charge trapping play the key role in determining the overall device efficiency. This work contributes to the knowledge of how charges drift through the polymer layer to finally find neutral emissive trap states and thus allows a quantitative prediction of the emission color of multichromophoric systems, compatible with the observed color shifts upon driving voltage and temperature variation as well as with electrical conditioning effects. In a more methodically oriented part, it is demonstrated that the transient device emission observed upon terminating the driving voltage can be used to monitor the decay of geminately-bound species as well as to determine trapped charge densities. This enables direct

  16. Transient thermo-structural and static magnetic characteristics of 1:1 prototype JET ELM control coils

    Energy Technology Data Exchange (ETDEWEB)

    Kundu, Ananya; Pradhan, Subrata, E-mail: pradhan@ipr.res.in; Ghate, Mahesh; Kanabar, Deven; Roy, Swati; Kumar, Nitish

    2017-01-15

    3D transient thermo-structural analyses and steady state magnetic field analyses of 1:1 prototyped JET Edge Localized Mode (ELM) coils have been carried out. Temperature distribution within the magnet winding as well as the temperature evolution have also been simulated as a function of pulsed transport currents in both large and small ELM coils as per the operational scenarios. The induced thermal stresses along with the shear stress components acting on the winding elements have also been analyzed. The deformations caused by thermal stresses have been calculated for the case, the conductor bundle and the insulation layers within the coils. In addition to thermo-structural analyses, steady state magnetic field analyses have also been carried out in the current carrying ELM coils. These values have been compared with the experimental values. The experimentally obtained values matches well with those obtained in simulations indicating that the prototyped ELM coils can operate successfully in JET operational scenarios. Additionally, the R & D and technologies developed in the context of JET ELM coils have also been validated with the magnet performances experimentally.

  17. Three-Dimensional View of Transient Horizontal Magnetic Fields in the Photosphere

    Czech Academy of Sciences Publication Activity Database

    Ishikawa, R.; Tsuneta, S.; Jurčák, Jan

    2010-01-01

    Roč. 713, č. 2 (2010), s. 1310-1321 ISSN 0004-637X R&D Projects: GA AV ČR IAA300030808 Institutional research plan: CEZ:AV0Z10030501 Keywords : magnetic fields * Sun * photosphere * granulation * surface magnetism Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 7.436, year: 2010

  18. Measurement of Fast Voltage Transients in High-Performance Nb3Sn Magnets

    Energy Technology Data Exchange (ETDEWEB)

    Lietzke, A. F.; Sabbi., G. L.; Ferracin, P.; Caspi, S.; Zimmerman, S.; Joseph, J.; Doering, D.; Lizarazo, J.

    2008-06-01

    The Superconducting Magnet group at Lawrence Berkeley National Laboratory has been developing Nb{sub 3}Sn high-field accelerator magnet technology for the last fifteen years. In order to support the magnet R&D effort, we are developing a diagnostic system that can help identify the causes of performance limiting quenches by recording small flux-changes within the magnet prior to quench-onset. These analysis techniques were applied to the test results from recent Nb{sub 3}Sn magnets. This paper will examine various types of events and their distinguishing characteristics. The present measurement techniques are discussed along with the design of a new data acquisition system that will substantially improve the quality of the recorded signals.

  19. Transient magnetized plasma as an optical element for high power laser pulses

    Directory of Open Access Journals (Sweden)

    Nobuhiko Nakanii

    2015-02-01

    Full Text Available Underdense plasma produced in gas jets by low intensity laser prepulses in the presence of a static magnetic field, B∼0.3  T, is shown experimentally to become an optical element allowing steering of tightly focused high power femtosecond laser pulses within several degrees along with essential enhancement of pulse’s focusability. Strong laser prepulses form a density ramp perpendicularly to magnetic field direction and, owing to the light refraction, main laser pulses propagate along the magnetic field even if it is tilted from the laser axis. Electrons generated in the laser pulse wake are well collimated and follow in the direction of the magnetic field; their characteristics are measured to be not sensitive to the tilt of magnetic field up to angles ±5°.

  20. Magnetic Resonance Imaging of Transient Left Ventricular Apical Ballooning Related to Emotional Stress: a Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mu Sook; Choi, Byoung Wook; Choe, Kyu Ok; Chung, Namsik [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-02-15

    Transient left ventricular apical ballooning is characterized by transient wall motion abnormalities involving the left ventricular apex and mid-ventricle in the absence of coronary arterial occlusion. A 66-year-old woman presented to the emergency department with chest pain that mimicked acute myocardial infarction. An aortogram showed akinesis from the mid to apical left ventricle with sparing of the basal segments. Four days later, she underwent MRI, which demonstrated characteristic apical contractile dysfunction, the same as the aortogram, without evidence of myocardial infarction on the MRI. Two weeks later, her symptoms were resolved and follow-up echocardiography showed normal ventricular function. We suggest that MRI might be an integrated imaging diagnostic tool for the diagnosis of this syndrome, which demonstrated characteristic apical contractile dysfunction with performing cine MRI, the absence of significant coronary artery stenosis with performing coronary MR angiography and the absence of myocardial infarction with performing contrast enhanced delayed MRI.

  1. Magnetic Resonance Imaging of Transient Left Ventricular Apical Ballooning Related to Emotional Stress: a Case Report

    International Nuclear Information System (INIS)

    Lee, Mu Sook; Choi, Byoung Wook; Choe, Kyu Ok; Chung, Namsik

    2007-01-01

    Transient left ventricular apical ballooning is characterized by transient wall motion abnormalities involving the left ventricular apex and mid-ventricle in the absence of coronary arterial occlusion. A 66-year-old woman presented to the emergency department with chest pain that mimicked acute myocardial infarction. An aortogram showed akinesis from the mid to apical left ventricle with sparing of the basal segments. Four days later, she underwent MRI, which demonstrated characteristic apical contractile dysfunction, the same as the aortogram, without evidence of myocardial infarction on the MRI. Two weeks later, her symptoms were resolved and follow-up echocardiography showed normal ventricular function. We suggest that MRI might be an integrated imaging diagnostic tool for the diagnosis of this syndrome, which demonstrated characteristic apical contractile dysfunction with performing cine MRI, the absence of significant coronary artery stenosis with performing coronary MR angiography and the absence of myocardial infarction with performing contrast enhanced delayed MRI

  2. Magnetic effects in cellular and molecular systems

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Brief discussions are presented of six aspects of the phenomenon. Individual topics discussed include: (1) mechanisms of magnetic field interactions with retinal rods; (2) orientation of biological membranes and cells in magnetic fields; (3) enzyme-substrate reactions in high magnetic fields; (4) effects on cell function resulting from exposure to strong magnetic fields at 4 0 K; (5) effects of a transverse magnetic field on the dose distribution of high energy electrons and in the responses of mammalian cells in vitro to x rays; and (6) effect of magnetic fields on the drug-induced contractility of the ciliate Spirostomum

  3. Plasma effect on tunnelling, charge transfer and transient quasimolecular states

    International Nuclear Information System (INIS)

    Fisher, D V

    2003-01-01

    The influence of a dense plasma environment on electron tunnelling between two ion potential wells in collectivized states and in charge-transfer collisions is studied. We show that the tunnelling probabilities in dilute plasma (in a close ion-ion collision) and in dense plasma differ strongly. The difference is due to the mixing between Stark components of donor-ion energy levels, caused by the field of spectator ions in a dense plasma. The mixing is determined by an angle α between the nearest-neighbour ion field and the total electric field acting on the donor ion. In close ion-ion binary collisions the mixing may be considered weak. However, for most plasma ions charge transfer, electron state collectivization and transient quasimolecule formation are strongly affected by the field of spectator ions. We derive approximate analytical expressions for the distribution function of α in an ideal plasma and perform molecular dynamics simulations to find the distribution function of α in both ideal and nonideal plasmas. Both α-dependent and average mixing coefficients are determined. We have found that the mixing is strong, even in ideal plasmas, and increases further with an increase in plasma nonideality. It is shown that there is no resonant charge transfer in dense plasmas. The applicability of a transient 'dicenter' quasimolecule model for dense plasmas is discussed

  4. Transient ElectroMagnetic and Electric Self-Potential survey in the TAG hydrothermal field in MAR

    Science.gov (United States)

    Tao, C.; Deng, X.; Wu, G.; Xi, Z.; Zhou, D.; Zuo, L.

    2012-12-01

    The TAG hydrothermal field is one of the most studied hydrothermal fields. This field covers an area of 5km×5km, which includes low-temperature Mn- and Fe-oxides and nontronites zone, relict massive sulfide mounds as well as active hydrothermal mound(TAG mound) [Thompson, 1985, Rona, 1993]. Drilling program was performed in the ODP (Ocean Drilling Program) Leg 158 in the TAG mound [Humphris, 1996]. In 1996, electrical resistivity survey in the TAG mound was conducted using innovative transient electric dipole-dipole instruments which was carried by DSV 'Alvin' [Cairns et al., 1996, Von Herzen et al., 1996]. In June 2012, the 2nd Leg of the Chinese 26th cruise was carried out in the TAG hydrothermal field at Mid Atlantic Ridge by R/V DAYANGYIHAO. Six TEM (Transient ElectroMagnetic) survey lines were deployed, with four of which across the ODP Leg 158 drilling area. Besides, two SP (Electric Self-Potential) survey lines were across the ODP drilling area. The survey results of TEM preliminary revealed the vertical structure of the TAG hydrothermal field. The survey results of both TEM and SP are consistent with the ODP drilling result, and also agree well with the temperature and water-column anomalies obtained in this leg. Preliminary results show that the TEM and SP methods are capable of revealing the horizontal and vertical distribution of the hydrothermal sulfide fields.

  5. Magnetic moment measurement of 140Ba nuclei using transient field technique

    International Nuclear Information System (INIS)

    Saxena, Mansi; Mandal, S.; Siwal, Davinder; Rainovski, G.; Danchev, M.; Damyanova, A.; Gladnishki, K.; Leske, J.; Bauer, C.; Bloch, T.; John, P.; Pietralla, N.; Wollersheim, H.J.; Kojouharov, I.; Pietri, S.; Schaffner, H.

    2011-01-01

    Mixed symmetry states have been identified in the neutron proton version of the Interacting Boson Model. The motivation of this experiment is to identify uniquely one phonon mixed symmetry states in 140 Ba nuclei by g factor measurement of the states. Magnetic moments measurements provide substantial information on the microscopic structure of the nuclei as the magnetic moment of a nuclei is described by the wave function of one state only. In this present paper we report the preliminary results of the g factor measurement of the first 2 + state of 140 Ba

  6. Magnetization effects from the g-2 inflector magnet superconductor

    International Nuclear Information System (INIS)

    Green, M.A.; Meng, W.

    1994-01-01

    The g-2 muon storage ring at Brookhaven National Laboratory will have a 1.7 meter long superconducting inflector magnet for injection of the muon beam into the storage ring. The field within the inflector is designed to be nearly zero. The inflector bucks out the main dipole field, but generates little or no stray field of its own. A portion of the field that remains is the field that is generated by circulating currents in the inflector magnet superconductor. Because the magnetization field has a different structure from field generated by the transport current, the magnetization field can adversely affect the field quality within the muon storage ring good field region. Correction of the effects of inflector superconductor magnetization and its effect on the good field region in the storage ring is discussed

  7. Evaluation of Transient Motion During Gadoxetic Acid-Enhanced Multiphasic Liver Magnetic Resonance Imaging Using Free-Breathing Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging.

    Science.gov (United States)

    Yoon, Jeong Hee; Lee, Jeong Min; Yu, Mi Hye; Hur, Bo Yun; Grimm, Robert; Block, Kai Tobias; Chandarana, Hersh; Kiefer, Berthold; Son, Yohan

    2018-01-01

    The aims of this study were to observe the pattern of transient motion after gadoxetic acid administration including incidence, onset, and duration, and to evaluate the clinical feasibility of free-breathing gadoxetic acid-enhanced liver magnetic resonance imaging using golden-angle radial sparse parallel (GRASP) imaging with respiratory gating. In this institutional review board-approved prospective study, 59 patients who provided informed consents were analyzed. Free-breathing dynamic T1-weighted images (T1WIs) were obtained using GRASP at 3 T after a standard dose of gadoxetic acid (0.025 mmol/kg) administration at a rate of 1 mL/s, and development of transient motion was monitored, which is defined as a distinctive respiratory frequency alteration of the self-gating MR signals. Early arterial, late arterial, and portal venous phases retrospectively reconstructed with and without respiratory gating and with different temporal resolutions (nongated 13.3-second, gated 13.3-second, gated 6-second T1WI) were evaluated for image quality and motion artifacts. Diagnostic performance in detecting focal liver lesions was compared among the 3 data sets. Transient motion (mean duration, 21.5 ± 13.0 seconds) was observed in 40.0% (23/59) of patients, 73.9% (17/23) of which developed within 15 seconds after gadoxetic acid administration. On late arterial phase, motion artifacts were significantly reduced on gated 13.3-second and 6-second T1WI (3.64 ± 0.34, 3.61 ± 0.36, respectively), compared with nongated 13.3-second T1WI (3.12 ± 0.51, P < 0.0001). Overall, image quality was the highest on gated 13.3-second T1WI (3.76 ± 0.39) followed by gated 6-second and nongated 13.3-second T1WI (3.39 ± 0.55, 2.57 ± 0.57, P < 0.0001). Only gated 6-second T1WI showed significantly higher detection performance than nongated 13.3-second T1WI (figure of merit, 0.69 [0.63-0.76]) vs 0.60 [0.56-0.65], P = 0.004). Transient motion developed in 40% (23/59) of patients shortly after

  8. Neuroprotective effect of agmatine in rats with transient cerebral ischemia using MR imaging and histopathologic evaluation.

    Science.gov (United States)

    Huang, Y C; Tzeng, W S; Wang, C C; Cheng, B C; Chang, Y K; Chen, H H; Lin, P C; Huang, T Y; Chuang, T J; Lin, J W; Chang, C P

    2013-09-01

    This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation. Following surgical induction of MCAO for 90min, agmatine was injected 5min after beginning of reperfusion and again once daily for the next 3 post-operative days. The events during ischemia and reperfusion were investigated by T2-weighted images (T2WI), serial diffusion-weighted images (DWI), calculated apparent diffusion coefficient (ADC) maps and contrast-enhanced T1-weighted images (CE-T1WI) during 3h-72h in a 1.5T Siemens MAGNETON Avanto Scanner. Lesion volumes were analyzed in a blinded and randomized manner. Triphenyltetrazolium chloride (TTC), Nissl, and Evans Blue stainings were performed at the corresponding sections. Increased lesion volumes derived from T2WI, DWI, ADC, CE-T1WI, and TTC all were noted at 3h and peaked at 24h-48h after MCAO injury. TTC-derived infarct volumes were not significantly different from the T2WI, DWI-, and CE-T1WI-derived lesion volumes at the last imaging time (72h) point except for significantly smaller ADC lesions in the MCAO model (Pagmatine-treated rats compared with the control ischemia rats (Pagmatine has neuroprotective effects against brain edema on a reperfusion model after transient cerebral ischemia. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Ant groups optimally amplify the effect of transiently informed individuals

    Science.gov (United States)

    Gelblum, Aviram; Pinkoviezky, Itai; Fonio, Ehud; Ghosh, Abhijit; Gov, Nir; Feinerman, Ofer

    2015-07-01

    To cooperatively transport a large load, it is important that carriers conform in their efforts and align their forces. A downside of behavioural conformism is that it may decrease the group's responsiveness to external information. Combining experiment and theory, we show how ants optimize collective transport. On the single-ant scale, optimization stems from decision rules that balance individuality and compliance. Macroscopically, these rules poise the system at the transition between random walk and ballistic motion where the collective response to the steering of a single informed ant is maximized. We relate this peak in response to the divergence of susceptibility at a phase transition. Our theoretical models predict that the ant-load system can be transitioned through the critical point of this mesoscopic system by varying its size; we present experiments supporting these predictions. Our findings show that efficient group-level processes can arise from transient amplification of individual-based knowledge.

  10. Hybrid Adaptive Filter development for the minimisation of transient fluctuations superimposed on electrotelluric field recordings mainly by magnetic storms

    Directory of Open Access Journals (Sweden)

    A. Konstantaras

    2006-01-01

    Full Text Available The method of Hybrid Adaptive Filtering (HAF aims to recover the recorded electric field signals from anomalies of magnetotelluric origin induced mainly by magnetic storms. An adaptive filter incorporating neuro-fuzzy technology has been developed to remove any significant distortions from the equivalent magnetic field signal, as retrieved from the original electric field signal by reversing the magnetotelluric method. Testing with further unseen data verifies the reliability of the model and demonstrates the effectiveness of the HAF method.

  11. Study of hyperfine transient field acting on the O16 excited nuclei (6.13 MeV, 3-) crossing iron and gadolinium magnetic foils

    International Nuclear Information System (INIS)

    Dekhissi, H.

    1985-07-01

    Precise measurements of transient magnetic field in iron and gadolinium have been obtained for oxygen ion at velocities from 2 to 8V o . At high recoil velocity, a transient field twice higher in gadolinium than in iron has been observed; this is contradictory with general predictions on transient field proportional growing with matrice polarization density. The degree of polarization can be deduced from transient field with measuring the ion fraction having an unpaired electron in K level. The resulting degree has been compared with theoretical estimations based on spin exchange, molecular orbital method, and polarized electron direct capture, as well as polarization mechanisms of 1s level of O 16 . Empiric forms aimed at the calibration of this field have been also tested [fr

  12. Transient magnetic currents through a molecular bridge: limits to reduction of non-equilibrium Green's functions to a generalized master equation

    Czech Academy of Sciences Publication Activity Database

    Kalvová, Anděla; Velický, B.; Špička, Václav

    2017-01-01

    Roč. 30, č. 3 (2017), s. 807-811 ISSN 1557-1939 Institutional support: RVO:68378271 Keywords : non-equilibrium * initial conditions * transient currents * molecular islands Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.180, year: 2016

  13. Analysis methods of stochastic transient electro–magnetic processes in electric traction system

    Directory of Open Access Journals (Sweden)

    T. M. Mishchenko

    2013-04-01

    Full Text Available Purpose. The essence and basic characteristics of calculation methods of transient electromagnetic processes in the elements and devices of non–linear dynamic electric traction systems taking into account the stochastic changes of voltages and currents in traction networks of power supply subsystem and power circuits of electric rolling stock are developed. Methodology. Classical methods and the methods of non–linear electric engineering, as well as probability theory method, especially the methods of stationary ergodic and non–stationary stochastic processes application are used in the research. Findings. Using the above-mentioned methods an equivalent circuit and the system of nonlinear integra–differential equations for electromagnetic condition of the double–track inter-substation zone of alternating current electric traction system are drawn up. Calculations allow obtaining electric traction current distribution in the areas of feeder zones. Originality. First of all the paper is interesting and important from scientific point of view due to the methods, which allow taking into account probabilistic character of change for traction voltages and electric traction system currents. On the second hand the researches develop the most efficient methods of nonlinear circuits’ analysis. Practical value. The practical value of the research is presented in application of the methods to the analysis of electromagnetic and electric energy processes in the traction power supply system in the case of high-speed train traffic.

  14. Interplanetary stream magnetism: Kinematic effects

    International Nuclear Information System (INIS)

    Burlaga, L.F.; Barouch, E.

    1976-01-01

    The particle density, and the magnetic field intensity and direction, are calculated for volume elements of the solar wind as a function of the initial magnetic field direction, Phi 0 , and the initial speed gradient, (deltaV/deltaR) 0 . It is assumed that the velocity is constant and radial. These assumptions are approximately valid between approx.0.1 and 1.0 AU for many streams. Time profiles of n, B, and V are calculated for corotating streams, neglecting effects of pressure gradients. The compression and rarefaction of B depend sensitively on Phi 0 . By averaging over a typical stream, it is found that approx.r -2 , whereas does not vary in a simple way, consistent with deep space observations. Changes of field direction may be very large, depending on the initial angle; but when the initial angle at 0.1 Au is such that the base of the field line corotates with the Sun, the spiral angle is the preferred direction at 1 AU. The theory is also applicable to nonstationary flows

  15. An Effective Distributed Model for Power System Transient Stability Analysis

    Directory of Open Access Journals (Sweden)

    MUTHU, B. M.

    2011-08-01

    Full Text Available The modern power systems consist of many interconnected synchronous generators having different inertia constants, connected with large transmission network and ever increasing demand for power exchange. The size of the power system grows exponentially due to increase in power demand. The data required for various power system applications have been stored in different formats in a heterogeneous environment. The power system applications themselves have been developed and deployed in different platforms and language paradigms. Interoperability between power system applications becomes a major issue because of the heterogeneous nature. The main aim of the paper is to develop a generalized distributed model for carrying out power system stability analysis. The more flexible and loosely coupled JAX-RPC model has been developed for representing transient stability analysis in large interconnected power systems. The proposed model includes Pre-Fault, During-Fault, Post-Fault and Swing Curve services which are accessible to the remote power system clients when the system is subjected to large disturbances. A generalized XML based model for data representation has also been proposed for exchanging data in order to enhance the interoperability between legacy power system applications. The performance measure, Round Trip Time (RTT is estimated for different power systems using the proposed JAX-RPC model and compared with the results obtained using traditional client-server and Java RMI models.

  16. Observations of white-light flares in NOAA active region 11515: high occurrence rate and relationship with magnetic transients

    Science.gov (United States)

    Song, Y. L.; Tian, H.; Zhang, M.; Ding, M. D.

    2018-06-01

    Aims: There are two goals in this study. One is to investigate how frequently white-light flares (WLFs) occur in a flare-productive active region (NOAA active region 11515). The other is to investigate the relationship between WLFs and magnetic transients (MTs). Methods: We used the high-cadence (45 s) full-disk continuum filtergrams and line-of-sight magnetograms taken by the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO) to identify WLFs and MTs, respectively. Images taken by the Atmospheric Imaging Assembly (AIA) on board SDO were also used to show the flare morphology in the upper atmosphere. Results: We found at least 20 WLFs out of a total of 70 flares above C class (28.6%) in NOAA active region 11515 during its passage across the solar disk (E45°-W45°). Each of these WLFs occurred in a small region, with a short duration of about 5 min. The enhancement of the white-light continuum intensity is usually small, with an average enhancement of 8.1%. The 20 WLFs we observed were found along an unusual configuration of the magnetic field that was characterized by a narrow ribbon of negative field. Furthermore, the WLFs were found to be accompanied by MTs, with radical changes in magnetic field strength (or even a sign reversal) observed during the flare. In contrast, there is no obvious signature of MTs in the 50 flares without white-light enhancements. Conclusions: Our results suggest that WLFs occur much more frequently than previously thought, with most WLFs being fairly weak enhancements. This may explain why WLFs are reported rarely. Our observations also suggest that MTs and WLFs are closely related and appear cospatial and cotemporal, when considering HMI data. A greater enhancement of WL emission is often accompanied by a greater change in the line-of-sight component of the unsigned magnetic field. Considering the close relationship between MTs and WLFs, many previously reported flares with MTs may be WLFs. The movie

  17. Pre-steady state transients in the Drosophila alcohol dehydrogenase catalyzed reaction: isotope effects and stereospecificity

    International Nuclear Information System (INIS)

    Place, A.R.; Eccleston, J.F.

    1987-01-01

    The alcohol dehydrogenase (ADH) isolated from Drosophila is unique among alcohol metabolizing enzymes by not requiring metals for catalysis, by showing 4-pro-S (B-sided) hydride transfer stereospecificity, and by possessing a greater catalytic turnover rate for secondary alcohols than for primary alcohols. They have extended their studies on the kinetic mechanism for this enzyme by examining the pre-steady state transients of ternary complex interconversion using stopped-flow fluorescence methods. When enzyme and a 30-fold molar excess of NADH is mixed with excess acetadehyde, methyl ethyl ketone (MEK), or cyclohexanone a rapid (> 100 s -1 ) transient is observe before the steady-state. The rates are insensitive to isotope substitution. With the substrate MEK, the rate and amplitude suggests a single turnover of the enzyme. Similar pre-steady state transients are observed when enzyme and a 50-fold molar excess of NAD + is mixed with ethanol, 2-propanol, and cyclohexanol. The rates show a hyperbolic concentration dependence and a deuterium isotope effect. With d 6 -deuteroethanol the transient no longer occurs in the pre-steady state. When the optical isomers of secondary alcohols are used as substrates, transients are observed only in the R-(-) isomers for all chain lengths. With 2-S(+)-heptanol and 2-S(+)-octanol no transients occur

  18. Effect of guideway discontinuities on magnetic levitation and drag forces

    International Nuclear Information System (INIS)

    Rossing, T.D.; Korte, R.; Hull, J.R.

    1991-01-01

    Transients in the lift and drag forces on a NdFeB permanent magnet were observed as the magnet passed over various discontinuities in a rotating aluminum disk at velocities of 4 to 25 m/s. For full cuts in the disk, the amplitude of the lift and drag transients and the wave form of the drag transient depend on the width, and the amplitudes are much larger than for partial cuts. The use of a backing plate to join two cut segments is ineffective

  19. Effects of slow repetitive transcranial magnetic stimulation in patients with corticobasal syndrome.

    Science.gov (United States)

    Civardi, Carlo; Pisano, Fabrizio; Delconte, Carmen; Collini, Alessandra; Monaco, Francesco

    2015-06-01

    Corticobasal syndrome is characterized by asymmetric cortical sensorimotor dysfunction and parkinsonism; an altered cortical excitability has been reported. We explored with transcranial magnetic stimulation the motor cortical excitability in corticobasal syndrome, and the effects of slow repetitive transcranial magnetic stimulation. With transcranial magnetic stimulation, we studied two corticobasal syndrome patients. We determined bilaterally from the first dorsal interosseous muscle: relaxed threshold, and contralateral and ipsilateral silent period. We also evaluated the contralateral silent period after active/sham slow repetitive transcranial magnetic stimulation on the most affected side. At T0 the silent period was bilaterally short. On the most affected side, active slow repetitive transcranial magnetic stimulation induced a short lasting prolongation of the contralateral silent period. In corticobasal syndrome, transcranial magnetic stimulation showed a reduction cortical inhibitory phenomenon potentially reversed transiently by slow repetitive transcranial magnetic stimulation.

  20. Gravitomagnetic effect in magnetized neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Chatterjee, Debarati [LPC/ENSICAEN, 6 Boulevard Maréchal Juin, Caen, 14050 France (France); Chakraborty, Chandrachur [Department of Astronomy and Astrophysics, Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai, 400005 India (India); Bandyopadhyay, Debades, E-mail: dchatterjee@lpccaen.in2p3.fr, E-mail: chandrachur.chakraborty@tifr.res.in, E-mail: debades.bandyopadhyay@saha.ac.in [Astroparticle Physics and Cosmology Division, Saha Institute of Nuclear Physics, HBNI, 1/AF Bidhannagar, Kolkata, 700064 India (India)

    2017-01-01

    Rotating bodies in General Relativity produce frame dragging, also known as the gravitomagnetic effect in analogy with classical electromagnetism. In this work, we study the effect of magnetic field on the gravitomagnetic effect in neutron stars with poloidal geometry, which is produced as a result of its rotation. We show that the magnetic field has a non-negligible impact on frame dragging. The maximum effect of the magnetic field appears along the polar direction, where the frame-dragging frequency decreases with increase in magnetic field, and along the equatorial direction, where its magnitude increases. For intermediate angles, the effect of the magnetic field decreases, and goes through a minimum for a particular angular value at which magnetic field has no effect on gravitomagnetism. Beyond that particular angle gravitomagnetic effect increases with increasing magnetic field. We try to identify this 'null region' for the case of magnetized neutron stars, both inside and outside, as a function of the magnetic field, and suggest a thought experiment to find the null region of a particular pulsar using the frame dragging effect.

  1. Transient performances analysis of wind turbine system with induction generator including flux saturation and skin effect

    DEFF Research Database (Denmark)

    Li, H.; Zhao, B.; Han, L.

    2010-01-01

    In order to analyze correctly the effect of different models for induction generators on the transient performances of large wind power generation, Wind turbine driven squirrel cage induction generator (SCIG) models taking into account both main and leakage flux saturation and skin effect were...

  2. Magnetic Resonance Imaging More Accurately Classifies Steatosis and Fibrosis in Patients With Nonalcoholic Fatty Liver Disease Than Transient Elastography.

    Science.gov (United States)

    Imajo, Kento; Kessoku, Takaomi; Honda, Yasushi; Tomeno, Wataru; Ogawa, Yuji; Mawatari, Hironori; Fujita, Koji; Yoneda, Masato; Taguri, Masataka; Hyogo, Hideyuki; Sumida, Yoshio; Ono, Masafumi; Eguchi, Yuichiro; Inoue, Tomio; Yamanaka, Takeharu; Wada, Koichiro; Saito, Satoru; Nakajima, Atsushi

    2016-03-01

    Noninvasive methods have been evaluated for the assessment of liver fibrosis and steatosis in patients with nonalcoholic fatty liver disease (NAFLD). We compared the ability of transient elastography (TE) with the M-probe, and magnetic resonance elastography (MRE) to assess liver fibrosis. Findings from magnetic resonance imaging (MRI)-based proton density fat fraction (PDFF) measurements were compared with those from TE-based controlled attenuation parameter (CAP) measurements to assess steatosis. We performed a cross-sectional study of 142 patients with NAFLD (identified by liver biopsy; mean body mass index, 28.1 kg/m(2)) in Japan from July 2013 through April 2015. Our study also included 10 comparable subjects without NAFLD (controls). All study subjects were evaluated by TE (including CAP measurements), MRI using the MRE and PDFF techniques. TE identified patients with fibrosis stage ≥2 with an area under the receiver operating characteristic (AUROC) curve value of 0.82 (95% confidence interval [CI]: 0.74-0.89), whereas MRE identified these patients with an AUROC curve value of 0.91 (95% CI: 0.86-0.96; P = .001). TE-based CAP measurements identified patients with hepatic steatosis grade ≥2 with an AUROC curve value of 0.73 (95% CI: 0.64-0.81) and PDFF methods identified them with an AUROC curve value of 0.90 (95% CI: 0.82-0.97; P steatosis in patients with NAFLD than TE and CAP methods. MRI-based noninvasive assessment of liver fibrosis and steatosis is a potential alternative to liver biopsy in clinical practice. UMIN Clinical Trials Registry No. UMIN000012757. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Effect of additional holes on transient thermal fatigue life of gas turbine casing

    Directory of Open Access Journals (Sweden)

    H. Bazvandi

    2017-10-01

    Full Text Available Gas turbines casings are susceptible to cracking at the edge of eccentric pin hole, which is the most likely position for crack initiation and propagation. This paper describes the improvement of transient thermal fatigue crack propagation life of gas turbines casings through the application of additional holes. The crack position and direction was determined using non-destructive tests. A series of finite element patterns were developed and tested in ASTM-A395 elastic perfectly-plastic ductile cast iron. The effect of arrangement of additional holes on transient thermal fatigue behavior of gas turbines casings containing hole edge cracks was investigated. ABAQUS finite element package and Zencrack fracture mechanics code were used for modeling. The effect of the reduction of transient thermal stress distribution around the eccentric pin hole on the transient thermal fatigue crack propagation life of the gas turbines casings was discussed. The result shows that transient thermal fatigue crack propagation life could be extended by applying additional holes of larger diameter and decreased by increasing the vertical distance, angle, and distance between the eccentric pin hole and the additional holes. The results from the numerical predictions were compared with experimental data.

  4. Transient Response Dynamic Module Modifications to Include Static and Kinetic Friction Effects

    Science.gov (United States)

    Misel, J. E.; Nenno, S. B.; Takahashi, D.

    1984-01-01

    A methodology that supports forced transient response dynamic solutions when both static and kinetic friction effects are included in a structural system model is described. Modifications that support this type of nonlinear transient response solution are summarized for the transient response dynamics (TRD) NASTRAN module. An overview of specific modifications for the NASTRAN processing subroutines, INITL, TRD1C, and TRD1D, are described with further details regarding inspection of nonlinear input definitions to define the type of nonlinear solution required, along with additional initialization requirements and specific calculation subroutines to successfully solve the transient response problem. The extension of the basic NASTRAN nonlinear methodology is presented through several stages of development to the point where constraint equations and residual flexibility effects are introduced into the finite difference Newmark-Beta recurrsion formulas. Particular emphasis is placed on cost effective solutions for large finite element models such as the Space Shuttle with friction degrees of freedom between the orbiter and payloads mounted in the cargo bay. An alteration to the dynamic finite difference equations of motion is discussed, which allows one to include friction effects at reasonable cost for large structural systems such as the Space Shuttle. Data are presented to indicate the possible impact of transient friction loads to the payload designer for the Space Shuttle. Transient response solution data are also included, which compare solutions without friction forces and those with friction forces for payloads mounted in the Space Shuttle cargo bay. These data indicate that payload components can be sensitive to friction induced loads.

  5. Magnetic resonance: safety measures and biological effects

    International Nuclear Information System (INIS)

    Gordillo, I.; Lafuente, J.; Fernandez, C.; Barbero, M.J.; Cascon, E.

    1997-01-01

    The biological effects of electromagnetic fields is currently a subject of great controversy. For this reason, magnetic resonance imaging (MRI) and spectroscopy are constantly under investigation. The source of the risk in MRI is associated with the three types of electromagnetic radiation to which the patient is exposed: the static magnetic field, variable (gradient) magnetic fields and radiofrequency fields. Each is capable of producing significant biological effects when employed at sufficient intensity. Patients exposed to risk sources are those situated within the lines of force of the magnetic field, ellipsoid lines that are arranged around the magnet, representing the strength of the surrounding field. To date, at the intensity normally utilized in MRI(<2T) and respecting the field limit recommendations established by the US Food and Drug Administration (FDA) for clinical use of this technique no adverse secondary biological effects have been reported. The known biological effects and other possible secondary effects are reviewed, and the recommended safety measures are discussed. (Author)

  6. ITER safety studies: The effect of two simultaneous perturbations during a loss of plasma control transient

    International Nuclear Information System (INIS)

    Rivas, J.C.; Dies, J.

    2014-01-01

    Highlights: •We have re-examined the methodology employed in the analysis of the “Loss of plasma transients in ITER” safety reference events. •We show the possible transient effects of a combined malfunction in external heating system and change in plasma confinement. •We show the possible transient effects of a combined malfunction in fuelling system and change in plasma confinement. •We have shown that new steady-states can be achieved that are potentially dangerous for the wall integrity. -- Abstract: The loss of plasma control events in ITER are safety cases investigated to give an upper bound of the worse effects foreseeable from a total failure of the plasma control function. Conservative analyses based on simple 0D models for plasma balance equations and 1D models for wall heat transfer are used to determine the effects of such transients on wall integrity from a thermal point of view. In this contribution, progress in a “two simultaneous perturbations over plasma” approach to the analysis of the loss of plasma control transients in ITER is presented. The effect of variation in confinement time is now considered, and the consequences of this variation are shown over a n–T diagram. The study has been done with the aid of AINA 3.0 code. This code implements the same 0D plasma-1D wall scheme used in previous LOPC studies. The rationale of this study is that, once the occurrence of a loss of plasma transient has been assumed, and due to the uncertainties in plasma physics, it does not seem so unlikely to assume the possibility of finding a new confinement mode during the transient. The cases selected are intended to answer to the question “what would happen if an unexpected change in plasma confinement conditions takes place during a loss of plasma control transient due to a simultaneous malfunction of heating, or fuelling systems?” Even taking into account the simple models used and the uncertainties in plasma physics and design data, the

  7. Effect of magnetic field on food freezing

    OpenAIRE

    村田, 圭治; 奥村, 太一; 荒賀, 浩一; 小堀, 康功

    2010-01-01

    [Abstract] This paper presents an experimental investigation on effects of magnetic field on food freezing process. Although purpose of food freezing is to suppress the deterioration of food, freezing breaks food tissue down, and some nutrient and delicious element flow out after thawing. Recently, a few of refrigeration equipments with electric and magnetic fields have attracted attention from food production companies and mass media. Water and tuna were freezed in magnetic field (100kH, 1.3...

  8. Effect of hydrostatic pressure on magnetic phase transitions and magnetization in gadolinium monocrystal

    International Nuclear Information System (INIS)

    Nikitin, S.A.; Bezdushnyj, R.V.

    1989-01-01

    Effect of hydrostatic pressure on magnetization in gadolinium monocrystal (Δσ-effect) was investigated. Dependences of spesific magnetization, Δσ-effect and bulk magnetostriction of gadolinium monocrystal on temperatures were studied. Results of conducted investigation have shown that in gadolinium the change of specific magnetization under the hydrostatic pressure effect is caused in general case by three effects: a)change of spontaneous magnetization under the effect of hydrostatic pressure; b)change of magnetization within technical magnetization range due to the effect of hydrostatic pressure on magnetic anisotropy constants; c)change of magnetization due to the effect of hydrostatic pressure on temperature of spin-reoriented transition

  9. The effects of transient conditions on the onset of intermittent dryout during blowdown

    Energy Technology Data Exchange (ETDEWEB)

    Statham, B.A., E-mail: stathaba@mcmaster.ca; Novog, D.R., E-mail: novog@mcmaster.ca

    2017-06-15

    Highlights: • This papers presents the results of an experimental investigation of transient critical heat flux in high quality and intermediate pressure water. • In existing literature conclusions vary from those showing no effect of transient conditions to results which show 30–40% improvement in CHF. • Along with new CHF data points in the liquid film dominated flow regime, the authors provide a methodology for producing bias free estimates of CHF based on existing correlations. • With these bias free CHF estimates, comparisons are made between transient and steady-state CHF at comparable local conditions. • The work concludes that based on consistently collected and analyzed data that quasi-steady CHF experiments adequately predict transient CHF using the same local thermalhydraulic conditions. - Abstract: For a given set of conditions in a boiling system the point of liquid film dryout or departure from nucleate boiling corresponds to the change from convective or nucleate boiling to transition or film boiling. This change is associated with a rapid deterioration of the heat transfer coefficient and the heat flux at this transition is denoted the critical heat flux (CHF). Computer models used to predict station transients and CHF rely heavily on empirical correlations to predict the CHF. Liquid film CHF data are usually obtained using a quasi-steady method wherein the heat flux is incremented in small steps with each step being allowed to reach a new equilibrium until an abnormal temperature increase is detected on the experimental surfaces. In applying a correlation derived from steady-state experiments to transient analyses these codes implicitly assume that dryout will occur for the same local conditions during transients as during steady state conditions. There is some disagreement in literature as to the validity of this hypothesis. This paper provides new steady-state and transient experimental data for CHF in water at intermediate pressures

  10. Transient state of electron transport in semiconductors: over velocity and ballistic effect

    International Nuclear Information System (INIS)

    Laval, S.

    1984-01-01

    As the dimensions of the active regions of electronic components are reduced, transient effects must be considered when electrons encounter a high electric field gradient. The electron velocity can overshoot its stationary value over a few tenths of a micron and during about one picosecond. This has been observed experimentally and permits to forecast new ultrafast electronic devices [fr

  11. Possible effects of oxidation on the transient release of fission gas from UO2

    International Nuclear Information System (INIS)

    Stoner, H.C.; Matthews, J.R.; Wood, M.H.

    1981-01-01

    The effect of varying the fuel composition from UO 2 to UOsub(2.3), on the transient behaviour of fission gas is simulated on the assumption that surface diffusion behaves in a similar manner to volume diffusion. The results may help in the understanding of fuel behaviour after pin failure in accident conditions in thermal reactor systems. (author)

  12. CMOS/SOS RAM transient radiation upset and ''inversion'' effect investigation

    International Nuclear Information System (INIS)

    Nikiforov, A.Y.; Poljakov, I.V.

    1996-01-01

    The Complementary Metal-Oxide-Semiconductor/Silicon-on-Sapphire Random Access Memory (CMOS/SOS RAM) transient upset and inversion effect were investigated with pulsed laser, pulsed voltage generator and low-intensity light simulators. It was found that the inversion of information occurs due to memory cell photocurrents simultaneously with the power supply voltage drop transfer to memory cells outputs

  13. Manifestation of transient effects in fission induced by relativistic heavy-ion collisions

    Energy Technology Data Exchange (ETDEWEB)

    Jurado, B.; Schmitt, C.; Schmidt, K.H.; Benlliure, J. [Universidad de Santiago de Compostela (Spain); Junghans, A.R. [Forschungszentrum Rossendorf e.V. (FZR), Dresden (Germany)

    2004-03-01

    We examine the manifestation of transient effects in fission by analysing experimental data where fission is induced by peripheral heavy-ion collisions at relativistic energies. Available total nuclear fission cross sections of {sup 238}U at1.A GeV on gold and uranium targets are compared with a nuclear-reaction code, where transient effects in fission are modelled using different approximations to the numerical time-dependent fission-decay width: a new analytical description based on the solution of the Fokker-Planck equation and two widely used but less realistic descriptions, a step function and an exponential-like function. The experimental data are only reproduced when transient effects are considered. The deduced value of the dissipation strength {beta} depends strongly on the approximation applied for the time-dependent fission-decay width and is estimated to be of the order of 2 x 10{sup 21} s{sup -1}. A careful analysis sheds severe doubts on the use of the exponential-like in-growth function largely used in the past. Finally, we discuss which should be the characteristics of experimental observables to be most sensitive to transient effects in fission. (orig.)

  14. Analyzing transient closed chamber effects on canopy gas exchange for optimizing flux calculation timing

    NARCIS (Netherlands)

    Langensiepen, M.; Kupisch, M.; Wijk, van M.T.; Ewert, F.

    2012-01-01

    Transient type canopy chambers are still the only currently available practical solution for rapid screening of gas-exchange in agricultural fields. The technique has been criticized for its effect on canopy microclimate during measurement which affects the transport regime and regulation of plant

  15. Susceptibility effects in nuclear magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ziener, Christian Herbert

    2008-01-01

    The properties of dephasing and the resulting relaxation of the magnetization are the basic principle on which all magnetic resonance imaging methods are based. The signal obtained from the gyrating spins is essentially determined by the properties of the considered tissue. Especially the susceptibility differences caused by magnetized materials (for example, deoxygenated blood, BOLD-effect) or magnetic nanoparticles are becoming more important for biomedical imaging. In the present work, the influence of such field inhomogeneities on the NMR-signal is analyzed. (orig.)

  16. Transient Monotonic and Cyclic Load Effects on Mono Bucket Foundations

    DEFF Research Database (Denmark)

    Nielsen, Søren Dam

    Today, 80 % of all European offshore wind turbines are installed on monopiles. A cost-effective alternative to the monopile is the mono bucket foundation. For an offshore wind turbine foundation in open seas, the dominant load is often coming from waves. During storms, large waves are formed...... the foundation is sucked to the seabed, creating extra capacity during the impact. Over the life-time of an offshore wind turbine foundation will be hit by millions of waves. Each wave might lead to a permanent rotation of the foundation. Therefore, it is important to be able to estimate the total deformation...

  17. Transient radiation effects in GaAs semiconductor devices

    International Nuclear Information System (INIS)

    Chang, J.Y.; Stauber, M.; Ezzeddine, A.; Howard, J.W.; Constantine, A.G.; Becker, M.; Block, R.C.

    1988-01-01

    This paper describes an ongoing program to identify the response of GaAs devices to intense pulses of ionizing radiation. The program consists of experimental measurements at the Rensselaer Polytechnic Institute's RPI electron linear accelerator (Linac) on generic GaAs devices built by Grumman Tachonics Corporation and the analysis of these results through computer simulation with the circuit model code SPICE (including radiation effects incorporated in the variations TRISPICE and TRIGSPICE and the device model code PISCES IIB). The objective of this program is the observation of the basic response phenomena and the development of accurate simulation tools so that results of Linac irradiations tests can be understood and predicted

  18. Magnetic after-effect in manganite films

    International Nuclear Information System (INIS)

    Sirena, M.; Steren, L.B.; Guimpel, J.

    2001-01-01

    The time dependence of the magnetic and transport properties on La 0.6 Sr 0.4 MnO 3 films and bulk samples has been studied through magnetization and resistivity measurements. A magnetic after-effect has been observed in all samples. At low temperatures, the low-field magnetization, can be described by the function M(t)=M c +M d exp(-t/τ)+S(H,T)ln(t). The resistivity increases logarithmically in the same temperature range, indicating the evolution of the sample to a more disordered state. Above a characteristic temperature, this behaviour is reversed and an increase of the magnetization with time is observed. The relaxation parameters depend on the bulk or films character of the samples. In the latter case, a dependence on the film thickness was found. A direct correlation between the time dependence of the resistivity and magnetization curves in manganite compounds was found

  19. Modeling the effect of transient populations on epidemics in Washington DC.

    Science.gov (United States)

    Parikh, Nidhi; Youssef, Mina; Swarup, Samarth; Eubank, Stephen

    2013-11-06

    Large numbers of transients visit big cities, where they come into contact with many people at crowded areas. However, epidemiological studies have not paid much attention to the role of this subpopulation in disease spread. We evaluate the effect of transients on epidemics by extending a synthetic population model for the Washington DC metro area to include leisure and business travelers. A synthetic population is obtained by combining multiple data sources to build a detailed minute-by-minute simulation of population interaction resulting in a contact network. We simulate an influenza-like illness over the contact network to evaluate the effects of transients on the number of infected residents. We find that there are significantly more infections when transients are considered. Since much population mixing happens at major tourism locations, we evaluate two targeted interventions: closing museums and promoting healthy behavior (such as the use of hand sanitizers, covering coughs, etc.) at museums. Surprisingly, closing museums has no beneficial effect. However, promoting healthy behavior at the museums can both reduce and delay the epidemic peak. We analytically derive the reproductive number and perform stability analysis using an ODE-based model.

  20. Modeling the effect of transient populations on epidemics in Washington DC

    Science.gov (United States)

    Parikh, Nidhi; Youssef, Mina; Swarup, Samarth; Eubank, Stephen

    2013-11-01

    Large numbers of transients visit big cities, where they come into contact with many people at crowded areas. However, epidemiological studies have not paid much attention to the role of this subpopulation in disease spread. We evaluate the effect of transients on epidemics by extending a synthetic population model for the Washington DC metro area to include leisure and business travelers. A synthetic population is obtained by combining multiple data sources to build a detailed minute-by-minute simulation of population interaction resulting in a contact network. We simulate an influenza-like illness over the contact network to evaluate the effects of transients on the number of infected residents. We find that there are significantly more infections when transients are considered. Since much population mixing happens at major tourism locations, we evaluate two targeted interventions: closing museums and promoting healthy behavior (such as the use of hand sanitizers, covering coughs, etc.) at museums. Surprisingly, closing museums has no beneficial effect. However, promoting healthy behavior at the museums can both reduce and delay the epidemic peak. We analytically derive the reproductive number and perform stability analysis using an ODE-based model.

  1. Nodalization effects on RELAP5 results related to MTR research reactor transient scenarios

    Directory of Open Access Journals (Sweden)

    Khedr Ahmed

    2005-01-01

    Full Text Available The present work deals with the anal y sis of RELAP5 results obtained from the evaluation study of the total loss of flow transient with the deficiency of the heat removal system in a research reactor using two different nodalizations. It focuses on the effect of nodalization on the thermal-hydraulic evaluation of the re search reactor. The analysis of RELAP5 results has shown that nodalization has a big effect on the predicted scenario of the postulated transient. There fore, great care should be taken during the nodalization of the reactor, especially when the avail able experimental or measured data are insufficient for making a complete qualification of the nodalization. Our analysis also shows that the research reactor pool simulation has a great effect on the evaluation of natural circulation flow and on other thermal-hydraulic parameters during the loss of flow transient. For example, the on set time of core boiling changes from less than 2000 s to 15000 s, starting from the beginning of the transient. This occurs if the pool is simulated by two vertical volumes in stead of one vertical volume.

  2. Interaction effects in magnetic oxide nanoparticle systems

    Indian Academy of Sciences (India)

    The interaction effects in magnetic nanoparticle system were studied through a Monte Carlo simulation. The results of simulations were compared with two different magnetic systems, namely, iron oxide polymer nanocomposites prepared by polymerization over core and nanocrystalline cobalt ferrite thin films prepared by ...

  3. Simulating Transient Effects of Pulsed Beams on Beam Intercepting Devices

    CERN Document Server

    Richter, Herta; Noah Messomo, Etam

    2011-01-01

    The development in the physics community towards higher beam power through the possibilities of particle accelerators lead to challenges for the developers of elements which are exposed to effect of particle beams (beam intercepting devices = BIDs). For the design of BIDs, the increasing heat load onto these devices due to energetic and focused beams and - in most cases - their highly pulsed nature has to be taken into account. The physics requirements are sometimes opposed to the current state of the art. As one possibility of many in combining the different aspects for these ambitious demands, two highly developed computer programs, namely FLUKA and ANSYS AUTODYN, were joined for this dissertation. The former is a widely enhanced Monte-Carlo-code which specializes on the interaction of particles with static matter, while the latter is a versatile explicit code for the simulation of highly dynamic processes. Both computer programs were developed intensively over years and are still continuously enhanced in o...

  4. Transient environmental effects of light alloy substitutions in transport vehicles

    International Nuclear Information System (INIS)

    Caceres, Carlos H.

    2009-01-01

    Materials indices and exchange constants are combined with Field et al.'s fleet analysis [Field F, Kirchain R, Clark J. Life-cycle assessment and temporal distributions of emissions: developing a fleet-based analysis. J Indust Ecol 2000;4:71-91, (doi:10.1162/108819800569816)] to examine the time-dependent CO 2 emissions attached to the production of the Al and Mg alloys used to reduce the mass of transport vehicles. The model is used to breakdown the temporal pattern of upfront emissions of passenger cars according to the mass and CO 2 -footprint efficiency of typical automotive structural substitutions (castings, stiff panels and stiff beams), accounting for the effect of recycling. The fleet's upfront emissions of Al and Mg castings with high content of secondary metal are offset by the increased fuel efficiency after 4 years of driving. Al beams and panels and electrolytic Mg panels require between 8 and 15 years, whereas for panels and beams of Pidgeon Mg no environmental benefits ever materialise.

  5. Transient Thunderstorm Downbursts and Their Effects on Wind Turbines

    Directory of Open Access Journals (Sweden)

    Hieu H. Nguyen

    2014-10-01

    Full Text Available The International Electrotechnical Commission (IEC Standard 61400-1 for the design of wind turbines does not explicitly address site-specific conditions associated with anomalous atmospheric events or conditions. Examples of off-standard atmospheric conditions include thunderstorm downbursts, hurricanes, tornadoes, low-level jets, etc. The simulation of thunderstorm downbursts and associated loads on a utility-scale wind turbine is the focus of this study. Since the problem has not received sufficient attention, especially in terms of design, we thus focus in this paper on practical aspects. A wind field model that incorporates component non-turbulent and turbulent parts is described and employed in inflow simulations. The non-turbulent part is based on an available analytical model with some modifications, while the turbulent part is simulated as a stochastic process using standard turbulence power spectral density functions and coherence functions whose defining parameters are related to the downburst characteristics such as the storm translation velocity. Available information on recorded downbursts is used to define two storm scenarios that are studied. Rotor loads are generated using stochastic simulation of the aeroelastic response of a model of a utility-scale 5-MW turbine. An illustrative single storm simulation and the associated turbine response are used to discuss load characteristics and to highlight storm-related and environmental parameters of interest. Extensive simulations for two downbursts are then conducted while varying the storm’s location and track relative to the turbine. Results suggest that wind turbine yaw and pitch control systems clearly influence overall system response. Results also highlight the important effects of both the turbulence as well as the downburst mean wind profiles on turbine extreme loads.

  6. Transient heating effects in high pressure Diesel injector nozzles

    International Nuclear Information System (INIS)

    Strotos, George; Koukouvinis, Phoevos; Theodorakakos, Andreas; Gavaises, Manolis; Bergeles, George

    2015-01-01

    Highlights: • Simulation of friction-induced heating in high pressure Diesel fuel injectors. • Injection pressures up to 3000 bar. • Simulations with variable fuel properties significantly affect predictions. • Needle motion affects flow and temperature fields. • Possible heterogeneous boiling as injection pressures increase above 2000 bar. - Abstract: The tendency of today’s fuel injection systems to reach injection pressures up to 3000 bar in order to meet forthcoming emission regulations may significantly increase liquid temperatures due to friction heating; this paper identifies numerically the importance of fuel pressurization, phase-change due to cavitation, wall heat transfer and needle valve motion on the fluid heating induced in high pressure Diesel fuel injectors. These parameters affect the nozzle discharge coefficient (C d ), fuel exit temperature, cavitation volume fraction and temperature distribution within the nozzle. Variable fuel properties, being a function of the local pressure and temperature are found necessary in order to simulate accurately the effects of depressurization and heating induced by friction forces. Comparison of CFD predictions against a 0-D thermodynamic model, indicates that although the mean exit temperature increase relative to the initial fuel temperature is proportional to (1 − C d 2 ) at fixed needle positions, it can significantly deviate from this value when the motion of the needle valve, controlling the opening and closing of the injection process, is taken into consideration. Increasing the inlet pressure from 2000 bar, which is the pressure utilized in today’s fuel systems to 3000 bar, results to significantly increased fluid temperatures above the boiling point of the Diesel fuel components and therefore regions of potential heterogeneous fuel boiling are identified

  7. Magnetization effects in electron cooling

    International Nuclear Information System (INIS)

    Derbenev, Ya.S.; Skrinskii, A.N.

    A study is made of cooling in an electron beam which is accompanied by a strong magnetic field and a longitudinal temperature low compared to the transverse temperature. It is shown that the combination of two factors--magnetization and low longitudinal temperature of electrons--can sharply increase the cooling rate of a heavy-particle beam when the velocity spread is smaller than the transverse spread of electron velocities and reduce its temperature to the longitudinal temperature of the electrons, which is lower than that of the cathode by several orders of magnitude

  8. Is There a Magnet-School Effect? A Multisite Study of MSAP-Funded Magnet Schools

    Science.gov (United States)

    Wang, Jia; Schweig, Jonathan D.; Herman, Joan L.

    2017-01-01

    Magnet schools are one of the largest sectors of choice schools in the United States. In this study, we explored the heterogeneity in magnet-school effects on student achievement by examining 24 magnet schools, funded under the Magnet Schools Assistance Program (MSAP), in 5 school districts across 4 states. The magnet effects were synthesized…

  9. Evaluation of core modeling effect on transients for multi-flow zone design of SFR

    International Nuclear Information System (INIS)

    Shin, Andong; Choi, Yong Won

    2016-01-01

    SFR core is composed of different types of assemblies including fuel driver, reflector, blanket, control, safety drivers and other drivers. Modeling of different types of assemblies is inevitable in general. But modeling of core flow zones of with different channels needs a lot of effort and could be a challenge for system code modeling due to its limitation on the number of modeling components. In this study, core modeling effect on SFR transient was investigated with flow-zone model and averaged inner core channel model to improve modeling efficiency and validation of simplified core model for EBR-II loss of flow transient case with the modified TRACE code for SFRs. Core modeling effect on the loss flow transient was analyzed with flow-zoned channel model, single averaged inner core model and highest flow channel with averaged inner core channel model for EBR-II SHRT-17 test core. Case study showed that estimations of transient pump and channel flow as well as channel outlet temperatures were similar for all cases macroscopically. Comparing the result of the base case (flow-zone channel inner core model) and the case 2 (highest flow channel considered averaged inner core channel model), flow and channel outlet temperature response were closer than the case1 (single averaged inner core model)

  10. Evaluation of core modeling effect on transients for multi-flow zone design of SFR

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Andong; Choi, Yong Won [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    SFR core is composed of different types of assemblies including fuel driver, reflector, blanket, control, safety drivers and other drivers. Modeling of different types of assemblies is inevitable in general. But modeling of core flow zones of with different channels needs a lot of effort and could be a challenge for system code modeling due to its limitation on the number of modeling components. In this study, core modeling effect on SFR transient was investigated with flow-zone model and averaged inner core channel model to improve modeling efficiency and validation of simplified core model for EBR-II loss of flow transient case with the modified TRACE code for SFRs. Core modeling effect on the loss flow transient was analyzed with flow-zoned channel model, single averaged inner core model and highest flow channel with averaged inner core channel model for EBR-II SHRT-17 test core. Case study showed that estimations of transient pump and channel flow as well as channel outlet temperatures were similar for all cases macroscopically. Comparing the result of the base case (flow-zone channel inner core model) and the case 2 (highest flow channel considered averaged inner core channel model), flow and channel outlet temperature response were closer than the case1 (single averaged inner core model)

  11. The integrated circuit IC EMP transient state disturbance effect experiment method investigates

    International Nuclear Information System (INIS)

    Li Xiaowei

    2004-01-01

    Transient state disturbance characteristic study on the integrated circuit, IC, need from its coupling path outset. Through cable (aerial) coupling, EMP converts to an pulse current voltage and results in the impact to the integrated circuit I/O orifice passing the cable. Aiming at the armament system construction feature, EMP effect to the integrated circuit, IC inside the system is analyzed. The integrated circuit, IC EMP effect experiment current injection method is investigated and a few experiments method is given. (authors)

  12. Effect of vortex generators on the closing transient flow of bileaflet mechanical heart valves

    Science.gov (United States)

    Murphy, David; Dasi, Lakshmi; Yoganathan, Ajit; Glezer, Ari

    2006-11-01

    The time-periodic closing of bileaflet mechanical heart valves is accompanied by a strong flow transient that is associated with the formation of a counter-rotating vortex pair near the b-datum line of leaflet edges. The strong transitory shear that is generated by these vortices may be damaging to blood elements and may result in platelet activation. In the present work, these flow transients are mitigated using miniature vortex generator arrays that are embedded on the surface of the leaflets. Two vortex generator designs were investigated: one design comprised staggered rectangular fins and the other one staggered hemispheres. The closing transients in the absence and presence of the passive vortex generators are characterized using phase locked PIV measurements. The study utilizes a 25 mm St. Jude Medical valve placed in the aortic position of the Georgia Tech left heart simulator. Measurements of the velocity field in the center plane of the leaflets demonstrate that the dynamics of the transient vortices that precede the formation of the leakage jets can be significantly altered and controlled by relatively simple passive modifications of existing valve designs. Human blood experiments validated the effectiveness of miniature vortex generators in reducing thrombus formation by over 42 percent.

  13. The effects of transient attention on spatial resolution and the size of the attentional cue.

    Science.gov (United States)

    Yeshurun, Yaffa; Carrasco, Marisa

    2008-01-01

    It has been shown that transient attention enhances spatial resolution, but is the effect of transient attention on spatial resolution modulated by the size of the attentional cue? Would a gradual increase in the size of the cue lead to a gradual decrement in spatial resolution? To test these hypotheses, we used a texture segmentation task in which performance depends on spatial resolution, and systematically manipulated the size of the attentional cue: A bar of different lengths (Experiment 1) or a frame of different sizes (Experiments 2-3) indicated the target region in a texture segmentation display. Observers indicated whether a target patch region (oriented line elements in a background of an orthogonal orientation), appearing at a range of eccentricities, was present in the first or the second interval. We replicated the attentional enhancement of spatial resolution found with small cues; attention improved performance at peripheral locations but impaired performance at central locations. However, there was no evidence of gradual resolution decrement with large cues. Transient attention enhanced spatial resolution at the attended location when it was attracted to that location by a small cue but did not affect resolution when it was attracted by a large cue. These results indicate that transient attention cannot adapt its operation on spatial resolution on the basis of the size of the attentional cue.

  14. Case study of a magnetic transient in NOAA 11429 observed by SDO/HMI during the M7.9 flare on 2012 march 13

    International Nuclear Information System (INIS)

    Harker, Brian J.; Pevtsov, Alexei A.

    2013-01-01

    NOAA 11429 was the source of an M7.9 X-ray flare at the western solar limb (N18° W63°) on 2012 March 13 at 17:12 UT. Observations of the line-of-sight magnetic flux and the Stokes I and V profiles from which it is derived were carried out by the Solar Dynamics Observatory Helioseismic and Magnetic Imager (SDO/HMI) with a 45 s cadence over the full disk, at a spatial sampling of 0.''5. During flare onset, a transient patch of negative flux can be observed in SDO/HMI magnetograms to rapidly appear within the positive polarity penumbra of NOAA 11429. We present here a detailed study of this magnetic transient and offer interpretations as to whether this highly debated phenomenon represents a 'real' change in the structure of the magnetic field at the site of the flare, or is instead a product of instrumental/algorithmic artifacts related to particular SDO/HMI data reduction techniques.

  15. Magnetic field considerations in fusion power plant environs

    International Nuclear Information System (INIS)

    Liemohn, H.B.; Lessor, D.L.; Duane, B.H.

    1976-09-01

    A summary of magnetic field production mechanisms and effects is given. Discussions are included on the following areas: (1) stray magnetic and electric fields from tokamaks, (2) methods for reducing magnetic fields, (3) economics of magnetic field reductions, (4) forces on magnetizable objects near magnetic confinement fusion reactors, (5) electric field transients in tokamaks, (6) attenuation and decay of electromagnetic fields, and (7) magnetic field transients from tokamak malfunctions

  16. Mode and climatic factors effect on energy losses in transient heat modes of transmission lines

    Science.gov (United States)

    Bigun, A. Ya; Sidorov, O. A.; Osipov, D. S.; Girshin, S. S.; Goryunov, V. N.; Petrova, E. V.

    2018-01-01

    Electrical energy losses increase in modern grids. The losses are connected with an increase in consumption. Existing models of electric power losses estimation considering climatic factors do not allow estimating the cable temperature in real time. Considering weather and mode factors in real time allows to meet effectively and safely the consumer’s needs to minimize energy losses during transmission, to use electric power equipment effectively. These factors increase an interest in the evaluation of the dynamic thermal mode of overhead transmission lines conductors. The article discusses an approximate analytic solution of the heat balance equation in the transient operation mode of overhead lines based on the least squares method. The accuracy of the results obtained is comparable with the results of solving the heat balance equation of transient thermal mode with the Runge-Kutt method. The analysis of mode and climatic factors effect on the cable temperature in a dynamic thermal mode is presented. The calculation of the maximum permissible current for variation of weather conditions is made. The average electric energy losses during the transient process are calculated with the change of wind, air temperature and solar radiation. The parameters having the greatest effect on the transmission capacity are identified.

  17. Effects of transient soil waterlogging and its importance for rootstock selection

    Directory of Open Access Journals (Sweden)

    Michelle Morales-Olmedo

    2015-08-01

    Full Text Available Under transient waterlogging, a number of transformations in the soil are generated associated with lack of aeration, seriously affecting the root system. Significant progress has been reported on understanding the effects of lack of oxygen on the metabolism of the roots, although few studies have examined changes in the soil. Diverging conclusions about the degree of tolerance exhibited by plants exclude the effects of hypoxia and anoxia on physical-chemical soil properties under plant experiments. This review examines the main changes occurring in soil and roots due to transient soil waterlogging conditions. Parameters such as antioxidant capacity, nutrient uptake dynamics and regeneration and distribution of the root system are relevant for selecting rootstocks tolerant to soil waterlogging.

  18. Gyromagnetic Faraday effect in transparent magnetic crystals

    International Nuclear Information System (INIS)

    Krinchik, G.S.; Koptsik, S.V.; Gan'shina, E.A.

    1982-01-01

    Faraday effect in the transparent paramagnetic Gd 3 Ga 5 O 12 at 4.2 K in magnetic fields up to 50 kE within 1-2.5 μm range is studied. The gyromagnetic Faraday effect caused by precession of magnetization vector under the effect of the magnetic field of wave light is shown to be the determinimg one in the infrared range. Hyromagnetic and gyroelectric contributions to Faraday effect in Gd 3 Fe 5 O 12 and Y 3 Fe 5 O 12 are determined. It is shown that field dependence of Faraday effect in non-colinear ferrimagnetic Yb 3 Fe 5 O 12 qualitatively proves the existence of gyromagnetic Faraday effect

  19. Transient effect of soil thermal diffusivity on performance of EATHE system

    OpenAIRE

    Mathur, Anuj; Srivastava, Ayushman; Mathur, Jyotirmay; Mathur, Sanjay; Agrawal, G.D.

    2015-01-01

    This paper presents effect of thermo-physical properties of soil on performance of an Earth Air Tunnel Heat Exchanger (EATHE). The analysis has been carried out using a validated three-dimensional, transient numerical model for three different types of soil. The governing equations, based on the k–ε model and energy equation were used to describe the turbulence and heat transfer phenomena, are solved by using finite volume method. Comparisons were made in terms of temperature drop, heat trans...

  20. Pressure effects on single chain magnets

    Energy Technology Data Exchange (ETDEWEB)

    Mito, M. E-mail: mitoh@elcs.kyutech.ac.jp; Shindo, N.; Tajiri, T.; Deguchi, H.; Takagi, S.; Miyasaka, H.; Yamashita, M.; Clerac, R.; Coulon, C

    2004-05-01

    Pressure effects on a single chain magnet [Mn{sub 2}(saltmen){sub 2}Ni(pao){sub 2}(py){sub 2}](ClO{sub 4}){sub 2} (saltmen{sup 2-}=N,N'-(1,1,2,2-tetramethylethylene)bis(salicylideneiminate), and pao{sup -}=pyridine-2-aldoximate) have been investigated through AC magnetic measurements under pressure (P). The slow relaxation of the magnetization depends on pressure. Both the blocking temperature (T{sub B}) and energy barrier ({delta}) increase by pressurization, and those enhancements saturate at around P=7 kbar.

  1. Inertial effects in systems with magnetic charge

    Science.gov (United States)

    Armitage, N. P.

    2018-05-01

    This short article sets out some of the basic considerations that go into detecting the mass of quasiparticles with effective magnetic charge in solids. Effective magnetic charges may be appear as defects in particular magnetic textures. A magnetic monopole is a defect in this texture and as such these are not monopoles in the actual magnetic field B, but instead in the auxiliary field H. They may have particular properties expected for such quasiparticles such as magnetic charge and mass. This effective mass may-in principle-be detected in the same fashion that the mass is detected of other particles classically e.g. through their inertial response to time-dependent electromagnetic fields. I discuss this physics in the context of the "simple" case of the quantum spin ices, but aspects are broadly applicable. Based on extensions to Ryzkhin's model for classical spin ice, a hydrodynamic formulation can be given that takes into account inertial and entropic forces. Ultimately, a form for the susceptibility is obtained that is equivalent to the Rocard equation, which is a classic form used to account for inertial effects in the context of Debye-like relaxation.

  2. User effects on the thermal-hydraulic transient system code calculations

    International Nuclear Information System (INIS)

    Aksan, S.N.; D'Auria, F.; Staedtke, H.

    1993-01-01

    In the paper, the results of the investigations on the user effects for the thermalhydraulic transient system codes will be presented and discussed on the basis of some case studies. The general findings of the investigations show that in addition to user effects, there are other reasons that affect the results of the calculations and which are hidden under user effects. Both the hidden factors and the direct user effects will be discussed in detail and general recommendations and conclusions will be presented to control and limit them. (orig.)

  3. Effects Of Hydrothermal Alteration On Magnetic Properties And Magnetic Signatures - Implications For Predictive Magnetic Exploration Models

    Science.gov (United States)

    Clark, D.

    2012-12-01

    Magnetics is the most widely used geophysical method in hard rock exploration and magnetic surveys are an integral part of exploration programs for many types of mineral deposit, including porphyry Cu, intrusive-related gold, volcanic-hosted epithermal Au, IOCG, VMS, and Ni sulfide deposits. However, the magnetic signatures of ore deposits and their associated mineralized systems are extremely variable and exploration that is based simply on searching for signatures that resemble those of known deposits and systems is rarely successful. Predictive magnetic exploration models are based upon well-established geological models, combined with magnetic property measurements and geological information from well-studied deposits, and guided by magnetic petrological understanding of the processes that create, destroy and modify magnetic minerals in rocks. These models are designed to guide exploration by predicting magnetic signatures that are appropriate to specific geological settings, taking into account factors such as tectonic province; protolith composition; post-formation tilting/faulting/ burial/ exhumation and partial erosion; and metamorphism. Patterns of zoned hydrothermal alteration are important indicators of potentially mineralized systems and, if properly interpreted, can provided vectors to ore. Magnetic signatures associated with these patterns at a range of scales can provide valuable information on prospectivity and can guide drilling, provided they are correctly interpreted in geological terms. This presentation reviews effects of the important types of hydrothermal alteration on magnetic properties within mineralized systems, with particular reference to porphyry copper and IOCG deposits. For example, an unmodified gold-rich porphyry copper system, emplaced into mafic-intermediate volcanic host rocks (such as Bajo de la Alumbrera, Argentina) exhibits an inner potassic zone that is strongly mineralized and magnetite-rich, which is surrounded by an outer

  4. Effect of helium pressure on the response of unirradiated UO2 subjected to thermal transients

    International Nuclear Information System (INIS)

    Fenske, G.R.; Chapello, P.M.; Emerson, J.E.; Poeppel, R.B.

    1983-01-01

    The effect of helium pressure on the transient response of unirradiated depleted UO 2 subjected to simulated hypothetical loss-of-flow accidents in a gas-cooled fast reactor was examined by use of the direct electrical heating technique. Transient tests were performed at pressures ranging from 7 to 10 X 10 5 Pa(7 to 10 atm) to 7 to 8 MPa (70 to 80 atm) on radially restrained and unrestrained fuel segments. The average heating rates ranged from about17 to 240 J/g x s. The results indicate that while the mechanical integrity of the fuel segment was independent of the test pressure, the rapid ejection of molten fuel from pellet interfaces of unrestrained fuel, observed at the lower pressures, was delayed or suppressed at the higher pressures

  5. Emergence of currents as a transient quantum effect in nonequilibrium systems

    Energy Technology Data Exchange (ETDEWEB)

    Granot, Er' el; Marchewka, Avi [Department of Electrical and Electronics Engineering, Ariel University Center of Samaria, Ariel (Israel)

    2011-09-15

    Most current calculations are based on equilibrium or semi-equilibrium models. However, except for very special scenarios (like ring configuration), the current cannot exist in equilibrium. Moreover, unlike with equilibrium scenarios, there is no generic approach to confront out-of-equilibrium currents. In this paper we used recent studies on transient quantum mechanics to solve the current, which appears in the presence of very high density gradients and fast transients. It shows that the emerging current appears instantaneously, and although the density beyond the discontinuity is initially negligible the currents there have a finite value, and remain constant for a finite period. It is shown that this nonequilibrium effect can be measured in real experiments (such as cooled rubidium atoms), where the discontinuity is replaced with a finite width (hundreds of nanometers) gradient.

  6. Emergence of currents as a transient quantum effect in nonequilibrium systems

    International Nuclear Information System (INIS)

    Granot, Er'el; Marchewka, Avi

    2011-01-01

    Most current calculations are based on equilibrium or semi-equilibrium models. However, except for very special scenarios (like ring configuration), the current cannot exist in equilibrium. Moreover, unlike with equilibrium scenarios, there is no generic approach to confront out-of-equilibrium currents. In this paper we used recent studies on transient quantum mechanics to solve the current, which appears in the presence of very high density gradients and fast transients. It shows that the emerging current appears instantaneously, and although the density beyond the discontinuity is initially negligible the currents there have a finite value, and remain constant for a finite period. It is shown that this nonequilibrium effect can be measured in real experiments (such as cooled rubidium atoms), where the discontinuity is replaced with a finite width (hundreds of nanometers) gradient.

  7. Emergence of currents as a transient quantum effect in nonequilibrium systems

    Science.gov (United States)

    Granot, Er'El; Marchewka, Avi

    2011-09-01

    Most current calculations are based on equilibrium or semi-equilibrium models. However, except for very special scenarios (like ring configuration), the current cannot exist in equilibrium. Moreover, unlike with equilibrium scenarios, there is no generic approach to confront out-of-equilibrium currents. In this paper we used recent studies on transient quantum mechanics to solve the current, which appears in the presence of very high density gradients and fast transients. It shows that the emerging current appears instantaneously, and although the density beyond the discontinuity is initially negligible the currents there have a finite value, and remain constant for a finite period. It is shown that this nonequilibrium effect can be measured in real experiments (such as cooled rubidium atoms), where the discontinuity is replaced with a finite width (hundreds of nanometers) gradient.

  8. Results from transient transport experiments in Rijnhuizen tokamak project: Heat convection, transport barriers and 'non-local' effects

    International Nuclear Information System (INIS)

    Mantica, P.; Gorini, G.; Hogeweij, G.M.D.; Kloe, J. de; Lopez Cardozo, N.J.; Schilham, A.M.R.

    2001-01-01

    An overview of experimental transport studies performed on the Rijnhuizen Tokamak Project (RTP) using transient transport techniques in both Ohmic and ECH dominated plasmas is presented. Modulated Electron Cyclotron Heating (ECH) and oblique pellet injection (OPI) have been used to induce electron temperature (T e ) perturbations at different radial locations. These were used to probe the electron transport barriers observed near low order rational magnetic surfaces in ECH dominated steady-state RTP plasmas. Layers of inward electron heat convection in off-axis ECH plasmas were detected with modulated ECH. This suggests that RTP electron transport barriers consist of heat pinch layers rather than layers of low thermal diffusivity. In a different set of experiments, OPI triggered a transient rise of the core T e due to an increase of the T e gradient in the 1< q<2 region. These transient transport barriers were probed with modulated ECH and found to be due to a transient drop of the electron heat diffusivity, except for off-axis ECH plasmas, where a transient inward pinch is also observed. Transient transport studies in RTP could not solve this puzzling interplay between heat diffusion and convection in determining an electron transport barrier. They nevertheless provided challenging experimental evidence both for theoretical modelling and for future experiments. (author)

  9. Magnetic field effects on electrochemical metal depositions

    Directory of Open Access Journals (Sweden)

    Andreas Bund, Adriana Ispas and Gerd Mutschke

    2008-01-01

    Full Text Available This paper discusses recent experimental and numerical results from the authors' labs on the effects of moderate magnetic (B fields in electrochemical reactions. The probably best understood effect of B fields during electrochemical reactions is the magnetohydrodynamic (MHD effect. In the majority of cases it manifests itself in increased mass transport rates which are a direct consequence of Lorentz forces in the bulk of the electrolyte. This enhanced mass transport can directly affect the electrocrystallization. The partial currents for the nucleation of nickel in magnetic fields were determined using an in situ micro-gravimetric technique and are discussed on the basis of the nucleation model of Heerman and Tarallo. Another focus of the paper is the numerical simulation of MHD effects on electrochemical metal depositions. A careful analysis of the governing equations shows that many MHD problems must be treated in a 3D geometry. In most cases there is a complex interplay of natural and magnetically driven convection.

  10. PSH Transient Simulation Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-21

    PSH Transient Simulation Modeling presentation from the WPTO FY14 - FY16 Peer Review. Transient effects are an important consideration when designing a PSH system, yet numerical techniques for hydraulic transient analysis still need improvements for adjustable-speed (AS) reversible pump-turbine applications.

  11. Magnetic Field Effects on Plasma Plumes

    Science.gov (United States)

    Ebersohn, F.; Shebalin, J.; Girimaji, S.; Staack, D.

    2012-01-01

    Here, we will discuss our numerical studies of plasma jets and loops, of basic interest for plasma propulsion and plasma astrophysics. Space plasma propulsion systems require strong guiding magnetic fields known as magnetic nozzles to control plasma flow and produce thrust. Propulsion methods currently being developed that require magnetic nozzles include the VAriable Specific Impulse Magnetoplasma Rocket (VASIMR) [1] and magnetoplasmadynamic thrusters. Magnetic nozzles are functionally similar to de Laval nozzles, but are inherently more complex due to electromagnetic field interactions. The two crucial physical phenomenon are thrust production and plasma detachment. Thrust production encompasses the energy conversion within the nozzle and momentum transfer to a spacecraft. Plasma detachment through magnetic reconnection addresses the problem of the fluid separating efficiently from the magnetic field lines to produce maximum thrust. Plasma jets similar to those of VASIMR will be studied with particular interest in dual jet configurations, which begin as a plasma loops between two nozzles. This research strives to fulfill a need for computational study of these systems and should culminate with a greater understanding of the crucial physics of magnetic nozzles with dual jet plasma thrusters, as well as astrophysics problems such as magnetic reconnection and dynamics of coronal loops.[2] To study this problem a novel, hybrid kinetic theory and single fluid magnetohydrodynamic (MHD) solver known as the Magneto-Gas Kinetic Method is used.[3] The solver is comprised of a "hydrodynamic" portion based on the Gas Kinetic Method and a "magnetic" portion that accounts for the electromagnetic behaviour of the fluid through source terms based on the resistive MHD equations. This method is being further developed to include additional physics such as the Hall effect. Here, we will discuss the current level of code development, as well as numerical simulation results

  12. A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

    Science.gov (United States)

    Shen, Yang-Wu; Ke, De-Ping; Sun, Yuan-Zhang; Daniel, Kirschen; Wang, Yi-Shen; Hu, Yuan-Chao

    2015-07-01

    A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. Project supported by the National Natural Science Foundation of China (Grant No. 51307124) and the Major Program of the National Natural Science Foundation of China (Grant No. 51190105).

  13. Effect of magnetic reconnection in stellar plasma

    Science.gov (United States)

    Hammoud, M.; El Eid, M.; Darwish, M.

    2017-06-01

    An important phenomenon in Astrophysics is the process of magnetic reconnection (MGR), which is envisaged to understand the solar flares, coronal mass ejection, interaction of the solar wind with the Earth’s magnetic field (so called geomagnetic storm) and other phenomena. In addition, it plays a role in the formation of stars. MGR involves topological change of a set of magnetic field lines leading to a new equilibrium configuration of lower magnetic energy. The MGR is basically described in the framework of the Maxwell’s equations linked to Navier-Stockes equations. Nevertheless, many details are still not understood. In this paper, we investigate the MGR process in the framework of the Magnetohydrodynamic (MHD) model of a single conducting fluid using a modern powerful computational tool (OpenFOAM). We will show that the MGR process takes place only if resistivity exists. However, despite the high conductivity of the plasma, resistivity becomes effective in a very thin layer generating sharp gradients of the magnetic field, and thus accelerating the reconnection process. The net effect of MGR is that magnetic energy is converted into thermal and kinetic energies leading to heating and acceleration of charged particles. The Sun’s coronal ejection is an example of the MGR process.

  14. Analysis of the Magnetic Field Effect on Entropy Generation at Thermosolutal Convection in a Square Cavity

    Directory of Open Access Journals (Sweden)

    Ammar Ben Brahim

    2011-05-01

    Full Text Available Thermosolutal convection in a square cavity filled with air and submitted to an inclined magnetic field is investigated numerically. The cavity is heated and cooled along the active walls with a mass gradient whereas the two other walls of the cavity are adiabatic and insulated. Entropy generation due to heat and mass transfer, fluid friction and magnetic effect has been determined in transient state for laminar flow by solving numerically the continuity, momentum energy and mass balance equations, using a Control Volume Finite—Element Method. The structure of the studied flows depends on four dimensionless parameters which are the Grashof number, the buoyancy ratio, the Hartman number and the inclination angle. The results show that the magnetic field parameter has a retarding effect on the flow in the cavity and this lead to a decrease of entropy generation, Temperature and concentration decrease with increasing value of the magnetic field parameter.

  15. Hysteretic memory effects in disordered magnets

    OpenAIRE

    Katzgraber, Helmut G.; Zimanyi, Gergely T.

    2005-01-01

    We study the return point as well as the complementary point memory effects numerically with paradigmatic models for random magnets and show that already simple systems with Ising spin symmetry can reproduce the experimental results of Pierce et al. where both memory effects become more pronounced for increasing disorder and return point memory is always better than complementary point memory.

  16. The particle concentration effect on magnetic resonance linewidth for magnetic liquids with chain aggregates

    International Nuclear Information System (INIS)

    Marin, C.N.

    2002-01-01

    Based on the assumption of particle chains formation within a magnetic liquid, computer simulation of the magnetic resonance line is presented. The dependence on particle concentration within a magnetic liquid of magnetic resonance linewidth is analyzed. The computer simulation demonstrates that the particles chaining has an important effect on the enlargement of the magnetic resonance line. Increasing the particle concentration within magnetic liquid leads to an increase in the linewidth. The agreement with some experimental findings is discussed

  17. Simulation of the effects of grain boundary fission gas during thermal transients

    International Nuclear Information System (INIS)

    Fenske, G.R.; Emerson, J.E.; Beiersdorf, B.A.

    1984-11-01

    This report presents the results of an initial set of out-of-cell transient heating experiments performed on unirradiated UO 2 pellets fabricated to simulate the effect of grain boundary fission gas on fuel swelling and cladding failure. The fabrication involved trapping high-pressure argon on internal pores by sintering annular UO 2 pellets in a hot isostatic press (HIP). The pellet stack was subjected to two separate transients (DGF83-03A and -03B). Figures show photomicrographs of HIPped and non-HIPped UO 2 , respectively, and the adjacent cladding after DGF83-03B. Fuel melting occurred at the center of both the HIPped and non-HIPped pellets; however, a dark ring is present near the center in the HIPped fuel but not in the non-HIPped fuel. This dark band is a high-porosity region due to increased grain boundary/edge swelling in that pellet. In contrast, grain boundary/edge swelling did not occur in the non-HIPped pellets. Thus, the presence of the high-pressure argon trapped on internal pores during sintering in the HIP altered the microstructural behavior. Results of these preliminary tests indicate that the microstructural behavior of HIPped fuel during thermal transients is different from the behavior of conventionally fabricated fuel

  18. Computing the effect of plastic deformation of piping on pressure transient propagation

    International Nuclear Information System (INIS)

    Youngdahl, C.K.; Kot, C.A.

    1977-01-01

    The computer program PTA-1 performs pressure-transient analysis of large piping networks using the one-dimensional method of characteristics applied to a fluid-hammer formulation. The effect of elastic-plastic deformation of piping on pulse propagation is included in the computation. Each pipe is modeled as a series of rings, neglecting axial effects, bending moments, and inertia. The fluid wave speed is a function of pipe deformation and, consequently, of position and time. Comparison with existing experimental data indicate that this simple fluid-structure interaction model gives suprisingly accurate results for both pressure histories in the fluid and strain histories in the piping

  19. Radiation effects on superconducting fusion magnet components

    International Nuclear Information System (INIS)

    Weber, H.W.

    2011-01-01

    Nuclear fusion devices based on the magnetic confinement principle heavily rely on the existence and performance of superconducting magnets and have always significantly contributed to advancing superconductor and magnet technology to their limits. In view of the presently ongoing construction of the tokamak device ITER and the stellerator device Wendelstein 7X and their record breaking parameters concerning size, complexity of design, stored energy, amperage, mechanical and magnetic forces, critical current densities and stability requirements, it is deemed timely to review another critical parameter that is practically unique to these devices, namely the radiation response of all magnet components to the lifetime fluence of fast neutrons and gamma rays produced by the fusion reactions of deuterium and tritium. I will review these radiation effects in turn for the currently employed standard "technical" low temperature superconductors NbTi and Nb 3 Sn, the stabilizing material (Cu) as well as the magnet insulation materials and conclude by discussing the potential of high temperature superconducting materials for future generations of fusion devices, such as DEMO. (author)

  20. Magnetic effects of interstitial hydrogen in nickel

    Energy Technology Data Exchange (ETDEWEB)

    León, Andrea [Departamento de Física, Universidad Técnica Federico Santa María, Valparaíso (Chile); Velásquez, E.A. [Facultad de Física y Centro de Investigación en Nanotecnología y Materiales Avanzados CIEN-UC, Pontificia Universidad Católica de Chile, Santiago (Chile); Centro para el Desarrollo de la Nanociencia y la Nanotecnología CEDENNA, Santiago (Chile); Grupo de Investigación en Modelamiento y Simulación Computacional, Universidad de San Buenaventura Sec. Medellín, Medellín (Colombia); Mazo-Zuluaga, J. [Grupo de Instrumentación Científica y Microelectrónica, Grupo de Estado Sólido, IF-FCEN, Universidad de Antioquia UdeA, Calle 70 No. 52-21, Medellín (Colombia); Mejía-López, J. [Facultad de Física y Centro de Investigación en Nanotecnología y Materiales Avanzados CIEN-UC, Pontificia Universidad Católica de Chile, Santiago (Chile); Centro para el Desarrollo de la Nanociencia y la Nanotecnología CEDENNA, Santiago (Chile); Florez, J.M. [Departamento de Física, Universidad Técnica Federico Santa María, Valparaíso (Chile); and others

    2017-01-01

    Hydrogen storage in materials is among the most relevant fields when thinking about energy conversion and storage. In this work we present a study that responds to a couple of questions concerning induced electronic changes that H produces in ferromagnetic nickel (Ni) host. We calculate and explain the change of magnetic properties of Ni with different concentrations of H. Density functional theory calculations (DFT) were performed for super-cells of fcc Ni with interstitial H in octahedral sites at different concentrations. In order to physically explain the effect of magnetization diminishing as the hydrogen concentration increases, we propose a simple Stoner type of model to describe the influence of the H impurity on the magnetic properties of Ni. The exchange splitting reduction, as shown in first principles calculations, is clearly explained within this physical model. Using a paramagnetic Ni fcc band with variable number of electrons and a Stoner model allow us to obtain the correct trend for the magnetic moment of the system as a function of the H concentration. - Highlights: • We calculate and explain the change of magnetic properties of Ni with different concentrations of H. • We propose a simple Stoner type of model to describe the influence of the H impurity on the magnetic properties of Ni. • The band exchange splitting reduction as the H concentration increases, is a consequence of the competition between the band energy term (kinetic energy) and the ferromagnetic energy term (Weiss field).

  1. Magnetic after-effect in manganite films

    Energy Technology Data Exchange (ETDEWEB)

    Sirena, M. E-mail: sirenam@ib.cnea.gov.ar; Steren, L.B.; Guimpel, J

    2001-05-01

    The time dependence of the magnetic and transport properties on La{sub 0.6}Sr{sub 0.4}MnO{sub 3} films and bulk samples has been studied through magnetization and resistivity measurements. A magnetic after-effect has been observed in all samples. At low temperatures, the low-field magnetization, can be described by the function M(t)=M{sub c}+M{sub d} exp(-t/{tau})+S(H,T)ln(t). The resistivity increases logarithmically in the same temperature range, indicating the evolution of the sample to a more disordered state. Above a characteristic temperature, this behaviour is reversed and an increase of the magnetization with time is observed. The relaxation parameters depend on the bulk or films character of the samples. In the latter case, a dependence on the film thickness was found. A direct correlation between the time dependence of the resistivity and magnetization curves in manganite compounds was found.

  2. Transient Relative Age Effects across annual age groups in National level Australian Swimming.

    Science.gov (United States)

    Cobley, Stephen; Abbott, Shaun; Dogramaci, Sera; Kable, Adam; Salter, James; Hintermann, Mirjam; Romann, Michael

    2017-12-29

    To determine the prevalence, magnitude and transient patterning of Relative Age Effects (RAEs) according to sex and stroke event across all age-groups at the Australian National age swimming Championships. Repeated years of cross-sectional participation data were examined. Participants were 6014 unique male (3185) and female (2829) swimmers (aged 12-18 years) who participated in Freestyle (50, 400m) and/or Breaststroke (100, 200m) at the National age swimming Championships between 2000-2014 (inclusive). RAE prevalence, magnitude and transience were determined using Chi-square tests and Cramer's V estimates for effect size. Odds Ratios (OR) and 95% Confidence Intervals (CI) examined relative age quartile discrepancies. These steps were applied across age-groups and according to sex and each stroke event. Consistent RAEs with large-medium effect sizes were evident for males at 12-15 years of age respectively, and with large-medium effects for females at 12-14 respectively across all four swimming strokes. RAE magnitude then consistently reduced with age across strokes (e.g., Q1 vs. Q4 OR range 16year old males=0.94-1.20; females=0.68-1.41). With few exceptions, by 15-16 years RAEs had typically dissipated; and by 17-18 years, descriptive and significant inverse RAEs emerged, reflecting overrepresentation of relatively younger swimmers. Performance advantages associated with relative age (and thereby likely growth and maturation) are transient. Greater consideration of transient performance and participation in athlete development systems is necessary. This may include revising the emphasis of sport programmes according to developmental stages and delaying forms of athlete selection to improve validity. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  3. Effects of a magnetic field on growth of porous alumina films on aluminum

    Energy Technology Data Exchange (ETDEWEB)

    Ispas, Adriana; Bund, Andreas [Technische Universitaet Dresden, Physikalische Chemie und Elektrochemie, 01062 Dresden (Germany); Vrublevsky, Igor, E-mail: vrublevsky@bsuir.edu.b [Belarusian State University of Informatics and Radioelectronics Minsk, Department of Micro and Nanoelectronics, 220013 Minsk (Belarus)

    2010-05-01

    The effects induced by a magnetic field on the oxide film growth on aluminum in sulfuric, oxalic, phosphoric and sulfamic acid, and on current transients during re-anodizing of porous alumina films in the barrier-type electrolyte, were studied. Aluminum films of 100 nm thickness were prepared by thermal evaporation on Si wafer substrates. We could show that the duration of the anodizing process increased by 33% during anodizing in sulfuric acid when a magnetic field was applied (0.7 T), compared to the process without a magnetic field. Interestingly, such a magnetic field effect was not found during anodizing in oxalic and sulfamic acid. The pore intervals were decreased by ca. 17% in oxalic acid. These findings were attributed to variations in electronic properties of the anodic oxide films formed in various electrolytes and interpreted on the basis of the influence of trapped electrons on the mobility of ions migrating during the film growth. The spin dependent tunneling of electrons into the surface layer of the oxide under the magnetic field could be responsible for the shifts of the current transients to lower potentials during re-anodizing of heat-treated oxalic and phosphoric acid alumina films.

  4. Transient hydrodynamic finite-size effects in simulations under periodic boundary conditions

    Science.gov (United States)

    Asta, Adelchi J.; Levesque, Maximilien; Vuilleumier, Rodolphe; Rotenberg, Benjamin

    2017-06-01

    We use lattice-Boltzmann and analytical calculations to investigate transient hydrodynamic finite-size effects induced by the use of periodic boundary conditions. These effects are inevitable in simulations at the molecular, mesoscopic, or continuum levels of description. We analyze the transient response to a local perturbation in the fluid and obtain the local velocity correlation function via linear response theory. This approach is validated by comparing the finite-size effects on the steady-state velocity with the known results for the diffusion coefficient. We next investigate the full time dependence of the local velocity autocorrelation function. We find at long times a crossover between the expected t-3 /2 hydrodynamic tail and an oscillatory exponential decay, and study the scaling with the system size of the crossover time, exponential rate and amplitude, and oscillation frequency. We interpret these results from the analytic solution of the compressible Navier-Stokes equation for the slowest modes, which are set by the system size. The present work not only provides a comprehensive analysis of hydrodynamic finite-size effects in bulk fluids, which arise regardless of the level of description and simulation algorithm, but also establishes the lattice-Boltzmann method as a suitable tool to investigate such effects in general.

  5. Occupational exposure of healthcare and research staff to static magnetic stray fields from 1.5–7 Tesla MRI scanners is associated with reporting of transient symptoms

    Science.gov (United States)

    Schaap, Kristel; Christopher-de Vries, Yvette; Mason, Catherine K; de Vocht, Frank; Portengen, Lützen; Kromhout, Hans

    2014-01-01

    Objectives Limited data is available about incidence of acute transient symptoms associated with occupational exposure to static magnetic stray fields from MRI scanners. We aimed to assess the incidence of these symptoms among healthcare and research staff working with MRI scanners, and their association with static magnetic field exposure. Methods We performed an observational study among 361 employees of 14 clinical and research MRI facilities in The Netherlands. Each participant completed a diary during one or more work shifts inside and/or outside the MRI facility, reporting work activities and symptoms (from a list of potentially MRI-related symptoms, complemented with unrelated symptoms) experienced during a working day. We analysed 633 diaries. Exposure categories were defined by strength and type of MRI scanner, using non-MRI shifts as the reference category for statistical analysis. Non-MRI shifts originated from MRI staff who also participated on MRI days, as well as CT radiographers who never worked with MRI. Results Varying per exposure category, symptoms were reported during 16–39% of the MRI work shifts. We observed a positive association between scanner strength and reported symptoms among healthcare and research staff working with closed-bore MRI scanners of 1.5 Tesla (T) and higher (1.5 T OR=1.88; 3.0 T OR=2.14; 7.0 T OR=4.17). This finding was mainly driven by reporting of vertigo and metallic taste. Conclusions The results suggest an exposure-response association between exposure to strong static magnetic fields (and associated motion-induced time-varying magnetic fields) and reporting of transient symptoms on the same day of exposure. Trial registration number 11-032/C PMID:24714654

  6. Optical investigation of effective permeability of dilute magnetic dielectrics with magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Ananya, E-mail: banerjee.ananya2008@gmail.com; Sarkar, A. [Dept. of Physics, Bijoy Krishna Girls’ College, 5/3 M.G. Road, Howrah 711101, W.B. (India)

    2016-05-06

    The prime objective of this paper is to investigate the magnetic nature of dilute magnetic dielectrics (DMD) under variation of external magnetic field. The said variation is studied over developed nano-sized Gadolinium Oxide as a DMD system. The observed experimental field variation of the effective magnetic permeability is analyzed results of optical experiment. The experiment records the variation of Brewster angle of incident polarized LASER beam from the surface of developed DMD specimen with applied out of plane external magnetic field. The effective refractive index and hence relative magnetic permeability were estimated following electro-magnetic theory. The overall results obtained and agreement between theory and experiment are good.

  7. Optical investigation of effective permeability of dilute magnetic dielectrics with magnetic field

    Science.gov (United States)

    Banerjee, Ananya; Sarkar, A.

    2016-05-01

    The prime objective of this paper is to investigate the magnetic nature of dilute magnetic dielectrics (DMD) under variation of external magnetic field. The said variation is studied over developed nano-sized Gadolinium Oxide as a DMD system. The observed experimental field variation of the effective magnetic permeability is analyzed results of optical experiment. The experiment records the variation of Brewster angle of incident polarized LASER beam from the surface of developed DMD specimen with applied out of plane external magnetic field. The effective refractive index and hence relative magnetic permeability were estimated following electro-magnetic theory. The overall results obtained and agreement between theory and experiment are good.

  8. Effect of external magnetic effect of external magnetic field annealing on magnetic texture of Mo containing NANOPERM-type alloys

    International Nuclear Information System (INIS)

    Kanuch, T.; Miglierini, M.; Greneche, J.-M.; Skorvanek, I.; Schaaf, P.

    2006-01-01

    External magnetic fields are known to modify microstructure of materials during their solidification and/or crystallisation. In an external magnetic field strong particle to particle interactions lead to a highly anisotropic microstructure. If the alloy is in ferromagnetic state, stronger particle magnetization - external field interactions and also particle-to-particle couplings are expected. To reveal the magnetic texture, originally amorphous precursors of Fe 76 Mo 8 Cu 1 B 15 were annealed at 510 grad C and 550 grad C in an external longitudinal and transverse magnetic field of 0.025 T and 0.8 T, respectively. Magnetic measurements were applied to follow the changes of saturation magnetization and coercive force. Moessbauer experiments were performed at room and liquid nitrogen temperature to provide an information about orientation of with respect to an external magnetic field. The obtained results were compared with those achieved on zero field annealed samples. We can conclude that such a low external magnetic fields applied during crystallisation cause no significant changes in the magnetic microstructural anisotropy. Afterwards, magneto-optical Kerr effect (MOKE) was applied to investigate possible changes at the surface of the ribbon as a function of annealing temperature and applied magnetic field. We observed combination of uniaxial anisotropy, which originates from the shape anisotropy, and four-fold anisotropy, which is a contribution from crystallites of nanometre size embedded in the residual amorphous matrix. We expect more pronounced effects on cobalt substituted (Fe1 -x Co x ) 76 Mo 8 Cu 1 B 15 alloy. (authors)

  9. Linear Magnetoelectric Effect by Orbital Magnetism

    NARCIS (Netherlands)

    Scaramucci, A.; Bousquet, E.; Fechner, M.; Mostovoy, M.; Spaldin, N. A.

    2012-01-01

    We use symmetry analysis and first-principles calculations to show that the linear magnetoelectric effect can originate from the response of orbital magnetic moments to the polar distortions induced by an applied electric field. Using LiFePO4 as a model compound we show that spin-orbit coupling

  10. Transient thermal effect, nonlinear refraction and nonlinear absorption properties of graphene oxide sheets in dispersion.

    Science.gov (United States)

    Zhang, Xiao-Liang; Liu, Zhi-Bo; Li, Xiao-Chun; Ma, Qiang; Chen, Xu-Dong; Tian, Jian-Guo; Xu, Yan-Fei; Chen, Yong-Sheng

    2013-03-25

    The nonlinear refraction (NLR) properties of graphene oxide (GO) in N, N-Dimethylformamide (DMF) was studied in nanosecond, picosecond and femtosecond time regimes by Z-scan technique. Results show that the dispersion of GO in DMF exhibits negative NLR properties in nanosecond time regime, which is mainly attributed to transient thermal effect in the dispersion. The dispersion also exhibits negative NLR in picosecond and femtosecond time regimes, which are arising from sp(2)- hybridized carbon domains and sp(3)- hybridized matrix in GO sheets. To illustrate the relations between NLR and nonlinear absorption (NLA), NLA properties of the dispersion were also studied in nanosecond, picosecond and femtosecond time regimes.

  11. New insight into the parasitic bipolar amplification effect in single event transient production

    International Nuclear Information System (INIS)

    Chen Jian-Jun; Chen Shu-Ming; Liang Bin; Deng Ke-Feng

    2012-01-01

    In this paper, a new method is proposed to study the mechanism of charge collection in single event transient (SET) production in 90 nm bulk complementary metal oxide semiconductor (CMOS) technology. We find that different from the case in the pMOSFET, the parasitic bipolar amplification effect (bipolar effect) in the balanced inverter does not exist in the nMOSFET after the ion striking. The influence of the substrate process on the bipolar effect is also studied in the pMOSFET. We find that the bipolar effect can be effectively mitigated by a buried deep P + -well layer and can be removed by a buried SO 2 layer. (condensed matter: structural, mechanical, and thermal properties)

  12. Spin and magnetization effects in plasmas

    International Nuclear Information System (INIS)

    Brodin, G; Marklund, M; Zamanian, J; Stefan, M

    2011-01-01

    Quantum effects in plasmas are of interest for a diverse set of systems, and have thus as a field been revived and attracted a lot of attention from a wide community over the past decade. In models of quantum plasmas, the effects studied mostly are due to the quantum particle dispersion and tunnelling. Such effects can be of importance in dense systems and on short length scales. There are also a number of effects related to spin and statistics. However, up to recently the magnetization effect in plasmas due to the intrinsic electron spin has been largely ignored. The magnetization dynamics of e.g. solids has many important applications, such as components for memory storage, but has also been discussed in more 'proper' plasma environments, such as fusion plasmas. Furthermore, also from a basic science point-of-view the effects of intrinsic spin and gyromagnetic effects are of considerable interest. Here we give a short review of a number of different models for treating magnetization effects in plasmas, with a focus on recent results. In particular, the transition between kinetic models and fluid models is discussed. We also give a number of examples of applications of such theories, as well as an outlook for possible future work.

  13. Coherent synchrotron radiation transient effects in the energy-dependent region

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Botman, Jan; Goloviznin, Vladimir; Wiel, Marnix van der

    2002-01-01

    Coherent synchrotron radiation (CSR) is a well known phenomenon that originates from coherent superposition of electromagnetic waves by ultrarelativistic electrons. CSR longitudinal effects during the passage of a Gaussian beam from a straight to a circular path have often been studied in a regime in which they are energy independent. Nevertheless, the approximations used in such a regime may fail in several practical situations, as in the case of low-energy injectors or for small-wavelength structures within the bunch distribution in CSR-related instability problems. These situations demand a deeper investigation of longitudinal transient effects in the region where the approximations above are no longer valid: a strong γ dependence is found, and described in this paper, in the rate of energy change induced by CSR during the transient of a Gaussian bunch between a straight and a circular path, which was studied with the help of the authors' previous work. Results show that the overall CSR longitudinal effects, in this case, are reduced. One of the outcomes of previous work by Saldin et al. was extended to this situation and very good agreement between the two studies was found

  14. Magnon Valve Effect between Two Magnetic Insulators

    Science.gov (United States)

    Wu, H.; Huang, L.; Fang, C.; Yang, B. S.; Wan, C. H.; Yu, G. Q.; Feng, J. F.; Wei, H. X.; Han, X. F.

    2018-03-01

    The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.

  15. Vibrating sample magnetometer 2D and 3D magnetization effects associated with different initial magnetization states

    Directory of Open Access Journals (Sweden)

    Ronald E. Lukins

    2017-05-01

    Full Text Available Differences in VSM magnetization vector rotation associated with various initial magnetization states were demonstrated. Procedures and criteria were developed to select sample orientation and initial magnetization states to allow for the combination of two different 2D measurements runs (with the same field profiles to generate a dataset that can be representative of actual 3D magnetization rotation. Nickel, cast iron, and low moment magnetic tape media were used to demonstrate these effects using hysteresis and remanent magnetization test sequences. These results can be used to generate 2D and 3D magnetic properties to better characterize magnetic phenomena which are inherently three dimensional. Example applications are magnetic tape-head orientation sensitivity, reinterpretation of 3D coercivity and other standard magnetic properties, and multi-dimensional shielding effectiveness.

  16. Geminate free radical processes and magnetic field effects

    International Nuclear Information System (INIS)

    Eveson, Robert W.

    2000-01-01

    This thesis is concerned with the study of the dynamics of radical pair recombination reactions in solution by flash photolysis Electron Spin Resonance (ESR) and the influence of low static external magnetic fields upon them (MFE). An outline of the concepts of ESR is presented, followed by the theories of Chemically Induced Dynamic Electron Polarisation (CIDEP) of transient radical pairs. This is then followed by a brief review of the flash photolysis ESR apparatus and application of the Bloch equations to solve the equations of time-resolved ESR. Completing the theory section is an overview of the mechanisms by which magnetic fields alter the course of a geminate radical pair reaction in solution. Experimental CIDEP observations of the radical pair produced on photolysis of 1,3-dihydroxypropanone are simulated using polarisation theory and applied to a random-walk diffusion model to find, for the first time, the geminate reaction probability in solutions of varying viscosity. CIDEP spectra of the radical pair formed on photolysis of hydroxypropanone in contrast are not accounted for by current polarisation theory. The discrepancy is due to moderately fast relaxation of the acyl radical, CH 3 CO·, which alters the relative intensities in the ST 0 RPM pattern of the counter radical. Calculations taking into account this now provide an adequate basis for simulation of the spectrum. This method also, in principle, represents a new method for the measurement of phase relaxation times. Concluding the ESR work is a CIDEP study of 2,4,6-trimethylbenzoyl diphenylphosphine oxide. Unusual spin polarisation phenomena are found. The time-resolved optical absorption spectroscopy technique used for detecting low magnetic field effects on neutral radical pair reactions is described. Various improvements to the experiment are discussed which result in the observation of the low field effect for a neutral radical pair produced by Norrish type II chemistry. This is followed by an

  17. Transient effects of sudden changes of heat load in a naturally ventilated room

    Science.gov (United States)

    Caulfield, C. P.; Bower, D. J.; Fitzgerald, S.; Woods, A. W.

    2006-11-01

    Using reduced numerical models and small-scale laboratory experiments, we investigate the transient effects of changing isolated heat loads discontinuously within a large, ventilated space. We consider the emptying filling box (with high and low openings) driven by a single isolated source of buoyancy. The original steady state consists of a buoyant layer, whose depth (for the simplest case of a point source plume) is determined by the geometric properties of the room alone. When the buoyancy flux of the source is increased, a new layer `fills' the room from the top with a more buoyant layer. The original layer disappears due to entrainment by the rising plume. The behaviour is qualitatively different when the source buoyancy flux is decreased. In this case, the rising plume fluid is now relatively dense, and so it inevitably collapses back to `intrude' below the original layer. In this case, the original layer disappears due to both draining through the upper opening, and penetrative entrainment by the dense plume. We compare the predictions of three numerical models using different penetrative entrainment parametrizations to a sequence of laboratory experiments. This entrainment reduces the density of the intruding layer, and so the rising plume eventually stalls, and no longer reaches the (draining) original layer. We demonstrate that it is necessary to consider the transient effects of penetrative entrainment when the reduction in source buoyancy flux is sufficiently small.

  18. Effect of transients on the beam in the Superconducting Supercollider Coupled-Cavity Linac

    International Nuclear Information System (INIS)

    Young, L.M.; Nath, S.

    1992-01-01

    Each module of the Superconducting Super Collider (SSC) Coupled-Cavity Linac (CCL) consists of eight tanks (10 accelerating cells each) coupled with bridge couplers. The radio frequency (rf) power drive is in the center of the module at the bridge coupler between the fourth and fifth tanks. In this simulation of the beam dynamics, the rf power is turned on 10 μs before the beam is turned on. This time lapse allows the fields to build up and stabilize before they are required by the beam. When the beam is turned on, the beam loading causes the fields to change. This transient state of the fields together with their effect on the beam is presented. A model has been developed to calculate field distribution throughout the module as a function of time. Beam dynamics simulations were run with the results of this model at several times during the beam pulse. An estimate of the effect of the transients is given by the results of these simulations

  19. Neuroprotective Effect of Xueshuantong for Injection (Lyophilized in Transient and Permanent Rat Cerebral Ischemia Model

    Directory of Open Access Journals (Sweden)

    Xumei Wang

    2015-01-01

    Full Text Available Xueshuantong for Injection (Lyophilized (XST, a Chinese Materia Medica standardized product extracted from Panax notoginseng (Burk., is used extensively for the treatment of cerebrovascular diseases such as acutely cerebral infarction clinically in China. In the present study, we evaluated the acute and extended protective effects of XST in different rat cerebral ischemic model and explored its effect on peroxiredoxin (Prx 6-toll-like receptor (TLR 4 signaling pathway. We found that XST treatment for 3 days could significantly inhibit transient middle cerebral artery occlusion (MCAO induced infarct volume and swelling percent and regulate the mRNA expression of interleukin-1β (IL-1β, IL-17, IL-23p19, tumor necrosis factor-α (TNFα, and inducible nitric oxide synthase (iNOS in brain. Further study demonstrated that treatment with XST suppressed the protein expression of peroxiredoxin (Prx 6-toll-like receptor (TLR 4 and phosphorylation level of p38 and upregulated the phosphorylation level of STAT3. In permanent MCAO rats, XST could reduce the infarct volume and swelling percent. Moreover, our results revealed that XST treatment could increase the rats’ weight and improve a batch of functional outcomes. In conclusion, the present data suggested that XST could protect against ischemia injury in transient and permanent MCAO rats, which might be related to Prx6-TLR4 pathway.

  20. The effect of transient conditions on synovial fluid protein aggregation lubrication.

    Science.gov (United States)

    Myant, Connor William; Cann, Philippa

    2014-06-01

    Little is known about the prevailing lubrication mechanisms in artificial articular joints and the way in which these mechanisms determine implant performance. The authors propose that interfacial film formation is determined by rheological changes local to the contact and is driven by aggregation of synovial fluid proteins within the contact inlet region. A direct relationship between contact film thickness and size of the protein aggregation within the inlet region has been observed. In this paper the latest experimental observations of the protein aggregation mechanism are presented for conditions which more closely mimic joint kinematics and loading. Lubricant films were measured for a series of bovine calf serum solutions for CoCrMo femoral component sliding against a glass disc. An optical interferometric apparatus was employed to study the effects of transient motion on lubricant film formation. Central film thickness was measured as a function of time for a series of transient entrainment conditions; start-up motion, steady-state and non-steady-state uni-directional sliding, and bi-directional sliding. The size of the inlet aggregations was found to be dependent upon the type of transient condition. Thick protective protein films were observed to build up within the main contact region for all uni-directional tests. In contrast the inlet aggregation was not observed for bi-directional tests. Contact film thickness and wear was found to be directly proportional to the presence of the inlet protein phase. The inlet phase and contact films were found to be fragile when disrupted by surface scratches or subjected to reversal of the sliding direction. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Investigation of collisional effects within the bending magnet region of a DIII-D neutral beamline

    International Nuclear Information System (INIS)

    Kessler, D.N.; Hong, R.; Kellman, D.H.

    1993-10-01

    The region between the pole faces of the DIII-D neutral beamline residual ion bending magnets is an area of transient high gas pressure which may cause beam defocusing and increased heating of beamline internal components due to collisional effects. An investigation of these effects helps in understanding residual ion trajectories and in providing information for studying in the beamline capability for operation with increased pulse duration. Examination of collisional effects, and of the possible existence of space charge blow-up, was carried out by injecting deuterium gas into the region between the magnet pole faces with rates varying from 0 to 18 torr-ell/sec. Thermocouple and waterflow calorimetry data were taken to measure the beamline component heating and beam powder deposition on the magnet pole shields, magnet louvers, ion dump, beam collimators, and calorimeter. Data was also taken at gas flow rates varying from 0 to 25 torr-ell/sec into the neutralizer cell and is compared with the magnet region gas injection data obtained. Results show that both collisional effects and space charge blow-up play a role in magnet region component heating and that neutralizer gas flow sufficiently reduces component heating without incurring unacceptable power losses through collisional effects

  2. The relevance of the dynamic stall effect for transient fault operations of active-stall wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Jauch, Clemens; Soerensen, Poul; Jensen, Birgitte Bak

    2005-06-15

    This article describes a methodology to quantify the influence of dynamic stall on transient fault operations of active-stall turbines. The model of the dynamic stall effect is introduced briefly. The behaviour of the dynamic stall model during a transient fault operation is described mathematically, and from this its effect quantified. Two quantities are chosen to describe the influence of the dynamic stall effect: one is active power and the other is time delay. Subsequently a transient fault scenario is simulated with and without the dynamic stall effect and the differences discussed. From this comparison, the conclusion is drawn that the dynamic stall effect has some influence on the post-fault behaviour of the wind turbine, and it is hence suggested that the dynamic stall effect is considered if an active-stall wind turbine is to be modelled realistically. (Author)

  3. The effect of high-flux H plasma exposure with simultaneous transient heat loads on tungsten surface damage and power handling

    NARCIS (Netherlands)

    van Eden, G. G.; Morgan, T. W.; van der Meiden, H. J.; J Matejicek,; T Chraska,; Wirtz, M.; De Temmerman, G.

    2014-01-01

    The performance of the full-W ITER divertor may be significantly affected by the interplay between steady-state plasma exposure and transient events. To address this issue, the effect of a high-flux H plasma on the thermal shock response of W to ELM-like transients has been investigated. Transient

  4. Effects of transients in LIGO suspensions on searches for gravitational waves.

    Science.gov (United States)

    Walker, M; Abbott, T D; Aston, S M; González, G; Macleod, D M; McIver, J; Abbott, B P; Abbott, R; Adams, C; Adhikari, R X; Anderson, S B; Ananyeva, A; Appert, S; Arai, K; Ballmer, S W; Barker, D; Barr, B; Barsotti, L; Bartlett, J; Bartos, I; Batch, J C; Bell, A S; Betzwieser, J; Billingsley, G; Birch, J; Biscans, S; Biwer, C; Blair, C D; Bork, R; Brooks, A F; Ciani, G; Clara, F; Countryman, S T; Cowart, M J; Coyne, D C; Cumming, A; Cunningham, L; Danzmann, K; Da Silva Costa, C F; Daw, E J; DeBra, D; DeRosa, R T; DeSalvo, R; Dooley, K L; Doravari, S; Driggers, J C; Dwyer, S E; Effler, A; Etzel, T; Evans, M; Evans, T M; Factourovich, M; Fair, H; Fernández Galiana, A; Fisher, R P; Fritschel, P; Frolov, V V; Fulda, P; Fyffe, M; Giaime, J A; Giardina, K D; Goetz, E; Goetz, R; Gras, S; Gray, C; Grote, H; Gushwa, K E; Gustafson, E K; Gustafson, R; Hall, E D; Hammond, G; Hanks, J; Hanson, J; Hardwick, T; Harry, G M; Heintze, M C; Heptonstall, A W; Hough, J; Izumi, K; Jones, R; Kandhasamy, S; Karki, S; Kasprzack, M; Kaufer, S; Kawabe, K; Kijbunchoo, N; King, E J; King, P J; Kissel, J S; Korth, W Z; Kuehn, G; Landry, M; Lantz, B; Lockerbie, N A; Lormand, M; Lundgren, A P; MacInnis, M; Márka, S; Márka, Z; Markosyan, A S; Maros, E; Martin, I W; Martynov, D V; Mason, K; Massinger, T J; Matichard, F; Mavalvala, N; McCarthy, R; McClelland, D E; McCormick, S; McIntyre, G; Mendell, G; Merilh, E L; Meyers, P M; Miller, J; Mittleman, R; Moreno, G; Mueller, G; Mullavey, A; Munch, J; Nuttall, L K; Oberling, J; Oliver, M; Oppermann, P; Oram, Richard J; O'Reilly, B; Ottaway, D J; Overmier, H; Palamos, J R; Paris, H R; Parker, W; Pele, A; Penn, S; Phelps, M; Pierro, V; Pinto, I; Principe, M; Prokhorov, L G; Puncken, O; Quetschke, V; Quintero, E A; Raab, F J; Radkins, H; Raffai, P; Reid, S; Reitze, D H; Robertson, N A; Rollins, J G; Roma, V J; Romie, J H; Rowan, S; Ryan, K; Sadecki, T; Sanchez, E J; Sandberg, V; Savage, R L; Schofield, R M S; Sellers, D; Shaddock, D A; Shaffer, T J; Shapiro, B; Shawhan, P; Shoemaker, D H; Sigg, D; Slagmolen, B J J; Smith, B; Smith, J R; Sorazu, B; Staley, A; Strain, K A; Tanner, D B; Taylor, R; Thomas, M; Thomas, P; Thorne, K A; Thrane, E; Torrie, C I; Traylor, G; Tuyenbayev, D; Vajente, G; Valdes, G; van Veggel, A A; Vecchio, A; Veitch, P J; Venkateswara, K; Vo, T; Vorvick, C; Ward, R L; Warner, J; Weaver, B; Weiss, R; Weßels, P; Willke, B; Wipf, C C; Worden, J; Wu, G; Yamamoto, H; Yancey, C C; Yu, Hang; Yu, Haocun; Zhang, L; Zucker, M E; Zweizig, J

    2017-12-01

    This paper presents an analysis of the transient behavior of the Advanced LIGO (Laser Interferometer Gravitational-wave Observatory) suspensions used to seismically isolate the optics. We have characterized the transients in the longitudinal motion of the quadruple suspensions during Advanced LIGO's first observing run. Propagation of transients between stages is consistent with modeled transfer functions, such that transient motion originating at the top of the suspension chain is significantly reduced in amplitude at the test mass. We find that there are transients seen by the longitudinal motion monitors of quadruple suspensions, but they are not significantly correlated with transient motion above the noise floor in the gravitational wave strain data, and therefore do not present a dominant source of background noise in the searches for transient gravitational wave signals. Using the suspension transfer functions, we compared the transients in a week of gravitational wave strain data with transients from a quadruple suspension. Of the strain transients between 10 and 60 Hz, 84% are loud enough that they would have appeared above the sensor noise in the top stage quadruple suspension monitors if they had originated at that stage at the same frequencies. We find no significant temporal correlation with the suspension transients in that stage, so we can rule out suspension motion originating at the top stage as the cause of those transients. However, only 3.2% of the gravitational wave strain transients are loud enough that they would have been seen by the second stage suspension sensors, and none of them are above the sensor noise levels of the penultimate stage. Therefore, we cannot eliminate the possibility of transient noise in the detectors originating in the intermediate stages of the suspension below the sensing noise.

  5. Magnetic resonance imaging: effects of magnetic field strength

    International Nuclear Information System (INIS)

    Crooks, L.E.; Arakawa, M.; Hoenninger, J.; McCarten, B.; Watts, J.; Kaufman, L.

    1984-01-01

    Magnetic resonance images of the head, abdomen, and pelvis of normal adult men were obtained using varying magnetic field strength, and measurements of T1 and T2 relaxations and of signal-to-noise (SN) ratios were determined. For any one spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part, and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields

  6. Modeling of Interfilament Coupling Currents and Their Effect on Magnet Quench Protection

    CERN Document Server

    Ravaioli, E; Chlachidze, G; Maciejewski, M; Sabbi, G; Stoynev, S E; Verweij, A

    2017-01-01

    Variations in the transport current of a superconducting magnet cause several types of transitory losses. Due to its relatively short time constant, usually of the order of a few tens of milliseconds, interfilament coupling loss can have a significant effect on the coil protection against overheating after a quench. This loss is deposited in the strands and can facilitate a more homogeneous transition to the normal state of the coil turns. Furthermore, the presence of local interfilament coupling currents reduces the magnet's differential inductance, which in turn provokes a faster discharge of the transport current. The lumped-element dynamic electrothermal model of a superconducting magnet has been developed to reproduce these effects. Simulations are compared to experimental electrical transients and found in good agreement. After its validation, the model can be used for predicting the performance of quench protection systems based on energy extraction, quench heaters, the newly developed coupling-loss-in...

  7. Effect of process on the magnetic properties of bonded NdFeB magnet

    International Nuclear Information System (INIS)

    Li, J.; Liu, Y.; Gao, S.J.; Li, M.; Wang, Y.Q.; Tu, M.J.

    2006-01-01

    The effects of magnetic separation, coupling treatment, lubricating treatment, preform and biaxial molding on the density and magnetic properties of bonded NdFeB magnet were investigated. The results demonstrate that magnetic separation separates the powders with low coercive force; coupling treatment improves the interfaces between the powders and the binders; decrease in volume fraction of the binder increases magnetic properties of the magnet; granular arrangement improves both the magnetic and mechanical properties when powders are arranged in certain size; lubricating treatment improves the formability of the magnet and preform and biaxial molding improves both density and magnetic properties greatly. Combining these methods, the density of the bonded NdFeB magnet can reach 6.52 g/cm 3 and the maximum energy product can reach 114 kJ/m 3

  8. Effect of process on the magnetic properties of bonded NdFeB magnet

    Energy Technology Data Exchange (ETDEWEB)

    Li, J. [School of Materials Science and Engineering, Sichuan University, Chengdu, 610065 (China); Liu, Y. [School of Materials Science and Engineering, Sichuan University, Chengdu, 610065 (China)]. E-mail: liuying5536@163.com; Gao, S.J. [School of Materials Science and Engineering, Sichuan University, Chengdu, 610065 (China); Li, M. [School of Materials Science and Engineering, Sichuan University, Chengdu, 610065 (China); Wang, Y.Q. [South-West Magnetic Science and Technology Developing Company, Mianyang, 621600 (China); Tu, M.J. [School of Materials Science and Engineering, Sichuan University, Chengdu, 610065 (China)

    2006-04-15

    The effects of magnetic separation, coupling treatment, lubricating treatment, preform and biaxial molding on the density and magnetic properties of bonded NdFeB magnet were investigated. The results demonstrate that magnetic separation separates the powders with low coercive force; coupling treatment improves the interfaces between the powders and the binders; decrease in volume fraction of the binder increases magnetic properties of the magnet; granular arrangement improves both the magnetic and mechanical properties when powders are arranged in certain size; lubricating treatment improves the formability of the magnet and preform and biaxial molding improves both density and magnetic properties greatly. Combining these methods, the density of the bonded NdFeB magnet can reach 6.52 g/cm{sup 3} and the maximum energy product can reach 114 kJ/m{sup 3}.

  9. The Effect of a Pulsed Magnetic Field on Domain Wall Resistance in Magnetic Nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Majidi, R; Tehranchi, M M; Tabrizi, K Ghafoori [Department of Physics, G.C., Shahid Beheshti University, Evin, 19838-63113, Tehran (Iran, Islamic Republic of); Phirouznia, A, E-mail: Teranchi@cc.sbu.ac.ir [Department of Physics, Azarbaijan University of Tarbiat Moallem, 53714-161 Tabriz (Iran, Islamic Republic of)

    2011-04-01

    The effect of a pulsed magnetic field on domain wall magnetoresistance for an ideal one-dimensional magnetic nanowire with a domain wall has been investigated. The analysis has been based on the Boltzmann transport equation, within the relaxation time approximation. The results indicate that the domain wall resistance increase when enhancing the magnetic field. The evaluation of local magnetization has been considered in the presence of a pulsed magnetic field. The time evaluation of the magnetization also has an effect on the domain wall resistance. The resistance depends on the contribution of the Zeeman and exchange interactions.

  10. The Effect of a Pulsed Magnetic Field on Domain Wall Resistance in Magnetic Nanowires

    International Nuclear Information System (INIS)

    Majidi, R; Tehranchi, M M; Tabrizi, K Ghafoori; Phirouznia, A

    2011-01-01

    The effect of a pulsed magnetic field on domain wall magnetoresistance for an ideal one-dimensional magnetic nanowire with a domain wall has been investigated. The analysis has been based on the Boltzmann transport equation, within the relaxation time approximation. The results indicate that the domain wall resistance increase when enhancing the magnetic field. The evaluation of local magnetization has been considered in the presence of a pulsed magnetic field. The time evaluation of the magnetization also has an effect on the domain wall resistance. The resistance depends on the contribution of the Zeeman and exchange interactions.

  11. Transient effects of ionizing and displacive radiation on the dielectric properties of ceramics

    Science.gov (United States)

    Goulding, R. H.; Zinkle, S. J.; Rasmussen, D. A.; Stoller, R. E.

    1996-03-01

    A resonant cavity technique was used to measure the dielectric constant and loss tangent of ceramic insulators at a frequency near 100 MHz during pulsed fission reactor irradiation near room temperature. Tests were performed on single crystal and several different grades of polycrystalline Al2O3, MgAl2O4, AlN, and Si3N4. Lead shielding experiments were performed for some of the irradiations in order to examine the importance of gamma ray versus neutron irradiation effects. With the exception of AlN, the dielectric constant of all of the ceramics decreased slightly (irradiation. The dielectric constant of AlN was observed to slightly increase during irradiation. Significant transient increases in the loss tangent to values as high as 6×10-3 occurred during pulsed reactor irradiation with peak ionizing and displacements per atom (dpa) radiation fields of 4.2×104 Gy/s and 2.4×10-6 dpa/s, respectively. The loss tangent measured during irradiation for the different ceramics did not show any correlation with the preirradiation or postirradiation values. Analysis of the results indicates that the transient increases in loss tangent are due to radiation induced increases in the electrical conductivity. The loss tangent increases were proportional to the ionizing dose rate in all materials except for AlN, which exhibited a dose rate exponent of ˜1.6.

  12. MASTER-2.0: Multi-purpose analyzer for static and transient effects of reactors

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Byung Oh; Song, Jae Seung; Joo, Han Gyu [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-01-01

    MASTER-2.0 (Multi-purpose Analyzer for Static and Transient Effects of Reactors) is a nuclear design code based on the two group diffusion theory to calculate the steady-state and transient pressurized water reactor core in a 3-dimensional Cartesian or hexagonal geometry. Its neutronics model solves the space-time dependent neutron diffusion equations with NIM(Nodal Integration Method), NEM (Nodal Expansion Method), AFEN (Analytic Function Expansion Nodal Method)/NEM Hybrid Method, NNEM (Non-linear Nodal Expansion Method) or NANM (Non-linear Analytic Nodal Method) for a Cartesian geometry and with AFEN/NEM Hybrid Method or NLFM (Non-linear Local Fine-Mesh Method) for a hexagonal one. Coarse mesh rebalancing, Krylov Subspace method and asymptotic extrapolation method are implemented to accelerate the convergence of iteration process. Master-2.0 performs microscopic depletion calculations using microscopic cross sections provided by CASMO-3 or HELIOS and also has the reconstruction capability of pin information by use of MSS-IAS (Method of Successive Smoothing with Improved Analytic Solution). For the thermal-hydraulic calculation, fuel temperature table or COBRA3-C/P model can be used selectively. In addition, MASTER-2.0 is designed to cover various PWRs including SMART as well as WH-and CE-type reactors, providing all data required in their design procedures. (author). 39 refs., 12 figs., 4 tabs.

  13. Master-3.0: multi-purpose analyzer for static and transient effects of reactors

    International Nuclear Information System (INIS)

    Cho, Byung Oh; Joo, Han Gyu; Cho, Jin Young; Song, Jae Seung; Zee, Sung Quun

    2002-03-01

    MASTER-3.0 (Multi-purpose Analyzer for Static and Transient Effects of Reactors) is a nuclear design code based on the multi-group diffusion theory to calculate the steady-state and transient pressurized water reactor core in a 3-dimensional Cartesian or hexagonal geometry. Its neutronics model solves the space-time dependent neutron diffusion equations with NIM (Nodal Integration Method), NEM (Nodal Expansion Method), AFEN (Analytic Function Expansion Nodal Method)/NEM Hybrid Method, NNEM (Non-linear Nodal Expansion Method) or NANM (Non-linear Analytic Nodal Method) for a Cartesian geometry and with NTPEN (Non-linear Triangle-based Polynomial Expansion Nodal Method), AFEN (Analytic Function Expansion Nodal)/NEM Hybrid Method or NLFM (Non-linear Local Fine-Mesh Method) for a hexagonal one. Coarse mesh rebalancing, Krylov Subspace method, energy group restriction/prolongation method and asymptotic extrapolation method are implemented to accelerate the convergence of iteration process. MASTER-3.0 performs microscopic depletion calculations using microscopic cross sections provided by CASMO-3 or HELIOS and also has the reconstruction capability of pin information by use of MSS-IAS (Method of Successive Smoothing with Improved Analytic Solution). For the thermal-hydraulic calculation, fuel temperature table or COBRA3-C/P or MATRA model can be used selectively. In addition, MASTER-3.0 is designed to cover various PWRs including SMART as well as WH- and CE-type reactors, providing all data required in their design procedures

  14. A comparison of the heating effect of magnetic fluid between the alternating and rotating magnetic field

    International Nuclear Information System (INIS)

    Beković, Miloš; Trlep, Mladen; Jesenik, Marko; Hamler, Anton

    2014-01-01

    Magnetic fluids are distinct magnetic materials that have recently been the subject of extensive research precisely because of their unique properties. One of them is the heating effect when exposed to alternating magnetic fields, wherein the objective is to use this property in medicine as an alternative method for the treatment of tumors in the body. In this paper, we focus on two methods of magnetizing magnetic fluids, firstly using the alternating magnetic field (AMF), and secondly with the rotational magnetic field (RMF). The effects of the first are scientifically well-established, whilst the impact of RMF has not as yet been investigated as presented in this article. So far the effects of RMF have only been studied at low frequencies and high amplitudes, or vice versa. This article presents the results of heating at high frequencies and high magnetic field amplitudes, and the results compared with AMF. This paper presents the construction and implementation of a measuring system which is suitable both types of magnetic field. - Highlights: • Development of a new measurement system for the characterization of magnetic fluids. • System enables pulsed magnetic field, or a rotary magnetic field. • Analysis of the conditions to create a rotational magnetic field by means of a double power supply. • Good agreement between the analytical and numerical calculation of magnetic field and measurements. • Increase of the heating power when sample is exposed to rotating field compared to pulsating field

  15. Levels-of-processing effects on recollection and familiarity during transient global amnesia and after recovery.

    Science.gov (United States)

    Thoma, Patrizia; Schwarz, Michael; Daum, Irene

    2010-11-01

    The aim of the present study was to investigate the pattern of recollection and familiarity deficits and the modulation of recognition memory performance by the depth of encoding (deep vs. shallow) in transient global amnesia (TGA). Ten patients with TGA and 11 control subjects were assessed during the acute stage and after recovery 7 to 19 days later. Both recollection and familiarity were impaired in the acute stage and showed significant, albeit not complete, recovery by the time of the postacute assessment. The patients did, however, show a significant levels-of-processing effect, which was significantly reduced in acute TGA, but not at follow-up. The significant levels-of-processing effect during acute TGA might be linked to recruitment of the prefrontal cortex. (c) 2010 APA, all rights reserved

  16. Temporal Damping Effect of the Yucca Mountain Fractured Saturated Rock on Transient Infiltration Pulses

    International Nuclear Information System (INIS)

    K. Zhang; Y.S. Wu; L. Pan

    2006-01-01

    Performance assessment of the Yucca Mountain unsaturated zone (UZ) as the site for an underground repository of high-level radioactive waste relies on the crucial assumption that water percolation processes in the unsaturated zone can be approximated as a steady-state condition. Justification of such an assumption is based on temporal damping effects of several geological units within the unsaturated tuff formation. In particular, the nonwelded tuff of the Paintbrush Group (PTn unit) at Yucca Mountain, because of its highly porous nature, has been conceptualized to have a significant capacity for temporally damping transient percolation fluxes. The objective of this study is to investigate these damping effects, using a three-dimensional (3-D) mountain-scale model as well as several one-dimensional (1-D) models. The 3-D model incorporates a wide variety of the updated field data for the highly heterogeneous unsaturated formation at Yucca Mountain. The model is first run to steady state and calibrated using field-measured data and then transient pulse infiltrations are applied to the model top boundary. Subsequent changes in percolation fluxes at the bottom of and within the PTn unit are examined under episodic infiltration boundary conditions. The 1-D model is used to examine the long-term response of the flow system to higher infiltration pulses, while the damping effect is also investigated through modeling tracer transport in the UZ under episodic infiltration condition. Simulation results show the existence of damping effects within the PTn unit and also indicate that the assumption of steady-state flow conditions below the PTn unit is reasonable. However, the study also finds that some fast flow paths along faults exist, causing vertical-flux quick responses at the PTn bottom to the episodic infiltration at the top boundary

  17. Low Dimensionality Effects in Complex Magnetic Oxides

    Science.gov (United States)

    Kelley, Paula J. Lampen

    Complex magnetic oxides represent a unique intersection of immense technological importance and fascinating physical phenomena originating from interwoven structural, electronic and magnetic degrees of freedom. The resulting energetically close competing orders can be controllably selected through external fields. Competing interactions and disorder represent an additional opportunity to systematically manipulate the properties of pure magnetic systems, leading to frustration, glassiness, and other novel phenomena while finite sample dimension plays a similar role in systems with long-range cooperative effects or large correlation lengths. A rigorous understanding of these effects in strongly correlated oxides is key to manipulating their functionality and device performance, but remains a challenging task. In this dissertation, we examine a number of problems related to intrinsic and extrinsic low dimensionality, disorder, and competing interactions in magnetic oxides by applying a unique combination of standard magnetometry techniques and unconventional magnetocaloric effect and transverse susceptibility measurements. The influence of dimensionality and disorder on the nature and critical properties of phase transitions in manganites is illustrated in La0.7 Ca0.3MnO3, in which both size reduction to the nanoscale and chemically-controlled quenched disorder are observed to induce a progressive weakening of the first-order nature of the transition, despite acting through the distinct mechanisms of surface effects and site dilution. In the second-order material La0.8Ca0.2MnO3, a strong magnetic field is found to drive the system toward its tricritical point as competition between exchange interactions in the inhomogeneous ground state is suppressed. In the presence of large phase separation stabilized by chemical disorder and long-range strain, dimensionality has a profound effect. With the systematic reduction of particle size in microscale-phase-separated (La, Pr

  18. Effect of Transient Maternal Hypotension on Apoptotic Cell Death in Foetal Rat Brain

    Directory of Open Access Journals (Sweden)

    Hamit Özyürek

    2014-03-01

    Full Text Available Background: Intrauterine perfusion insufficiency induced by transient maternal hypotension has been reported to be associated with foetal brain malformations. However, the effects of maternal hypotension on apoptotic processes in the foetal brain have not been investigated experimentally during the intrauterine period. Aims: The aim of this study was to investigate the effects of transient maternal hypotension on apoptotic cell death in the intrauterine foetal brain. Study Design: Animal experimentation. Methods: Three-month-old female Wistar albino rats were allocated into four groups (n=5 each. The impact of hypoxic/ischemic injury induced by transient maternal hypotension on the 15th day of pregnancy (late gestation in rats was investigated at 48 (H17 group or 96 hours (H19 group after the insult. Control groups underwent the same procedure except for induction of hypotension (C17 and H17 groups. Brain sections of one randomly selected foetus from each pregnant rat were histopathologically evaluated for hypoxic/ischemic injury in the metencephalon, diencephalon, and telencephalon by terminal transferase-mediated dUTP nick end labelling and active cysteine-dependent aspartate-directed protease-3 (caspase-3 positivity for cell death. Results: The number of terminal transferase-mediated dUTP nick end labelling (+ cells in all the areas examined was comparable in both hypotension and control groups. The H17 group had active caspase-3 (+ cells in the metencephalon and telencephalon, sparing diencephalon, whereas the C19 and H19 groups had active caspase-3 (+ cells in all three regions. The number of active caspase-3 (+ cells in the telencephalon in the H19 group was higher compared with the metencephalon and diencephalon and compared with H17 group (p<0.05. Conclusion: Our results suggest that prenatal hypoxic/ischemic injury triggers apoptotic mechanisms. Therefore, blockade of apoptotic pathways, considering the time pattern of the insult, may

  19. The effect of dipolar interaction on the magnetic isotope effect

    DEFF Research Database (Denmark)

    Mojaza, Matin; Pedersen, Jørgen Boiden; Lukzen, Nikita

    2010-01-01

    A multi-channel kinetic description is used to study the magnetic isotope effect (MIE) in zero magnetic field. The maximal isotope effect is equal to the number of channels, two for the hyperfine interaction but four for the electron spin dipole–dipole interaction of the intermediate radical pair....... Quantum mechanical calculations agree with these conclusion and show that large MIE may be obtained even in the presence of a strong exchange interaction. The observed magnesium isotope effect on the rate of enzymatic synthesis of adenosine triphosphate (ATP) is approximately 3 implying that the dipolar...... interaction is responsible for the effect. Our calculations provide support for the proposed mechanism....

  20. Magnetic field effect on flow parameters of blood along with magnetic particles in a cylindrical tube

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Shashi, E-mail: shashisharma1984@gmail.com; Singh, Uaday; Katiyar, V.K.

    2015-03-01

    In this paper, the effect of external uniform magnetic field on flow parameters of both blood and magnetic particles is reported through a mathematical model using magnetohydrodynamics (MHD) approach. The fluid is acted upon by a varying pressure gradient and an external uniform magnetic field is applied perpendicular to the cylindrical tube. The governing nonlinear partial differential equations were solved numerically and found that flow parameters are affected by the influence of magnetic field. Further, artificial blood (75% water+25% Glycerol) along with iron oxide magnetic particles were prepared and transported into a glass tube with help of a peristaltic pump. The velocity of artificial blood along with magnetic particles was experimentally measured at different magnetic fields ranging from 100 to 600 mT. The model results show that the velocity of blood and magnetic particles is appreciably reduced under the influence of magnetic field, which is supported by our experimental results. - Highlights: • Effect of magnetic field on flow parameters of blood and magnetic particles is studied. • The velocity of blood and magnetic particles is appreciably reduced under a magnetic field. • Experimental results of the velocity of magnetic particles within blood support the mathematical model results.

  1. Transient Simulation Study of Slip-Frequency Vector Control for Variable Speed Doubly-Fed Brushless Motor with Magnetic Barrier Rotor

    Directory of Open Access Journals (Sweden)

    Jingxiong ZHANG

    2014-01-01

    Full Text Available In this paper, a transient simulation model of a variable speed doubly fed brushless motor (DFBM using back-to-back converter is described. Based on analysis of rotor flux oriented vector control theory of doubly fed induction motor, the control of the currents in DFBM that produce the magnetic flux and the torque is achieved by a digital controller, the speed is regulated by a PI controller which is tuned by a genetic algorithm. According to the state equation of DFBM and the control schemes, the system simulation module is established in MATLAB/ SIMULINK. An extensive simulation study is performed to examine the control characteristics of the machine-side converter under different operation conditions in variable-speed DFBM driver system.

  2. Magnetic field effects in hybrid perovskite devices

    Science.gov (United States)

    Zhang, C.; Sun, D.; Sheng, C.-X.; Zhai, Y. X.; Mielczarek, K.; Zakhidov, A.; Vardeny, Z. V.

    2015-05-01

    Magnetic field effects have been a successful tool for studying carrier dynamics in organic semiconductors as the weak spin-orbit coupling in these materials gives rise to long spin relaxation times. As the spin-orbit coupling is strong in organic-inorganic hybrid perovskites, which are promising materials for photovoltaic and light-emitting applications, magnetic field effects are expected to be negligible in these optoelectronic devices. We measured significant magneto-photocurrent, magneto-electroluminescence and magneto-photoluminescence responses in hybrid perovskite devices and thin films, where the amplitude and shape are correlated to each other through the electron-hole lifetime, which depends on the perovskite film morphology. We attribute these responses to magnetic-field-induced spin-mixing of the photogenerated electron-hole pairs with different g-factors--the Δg model. We validate this model by measuring large Δg (~ 0.65) using field-induced circularly polarized photoluminescence, and electron-hole pair lifetime using picosecond pump-probe spectroscopy.

  3. Effect of Anode Magnetic Shield on Magnetic Field and Ion Beam in Cylindrical Hall Thruster

    International Nuclear Information System (INIS)

    Zhao Jie; Wang Shiqing; Liu Jian; Xu Li; Tang Deli; Geng Shaofei

    2010-01-01

    Numerical simulation of the effect of the anode magnetic shielding on the magnetic field and ion beam in a cylindrical Hall thruster is presented. The results show that after the anode is shielded by the magnetic shield, the magnetic field lines near the anode surface are obviously convex curved, the ratio of the magnetic mirror is enhanced, the width of the positive magnetic field gradient becomes larger than that without the anode magnetic shielding, the radial magnetic field component is enhanced, and the discharge plasma turbulence is reduced as a result of keeping the original saddle field profile and the important role the other two saddle field profiles play in restricting electrons. The results of the particle in cell (PIC) numerical simulation show that both the ion number and the energy of the ion beam increase after the anode is shielded by the magnetic shield. In other words, the specific impulse of the cylindrical Hall thruster is enhanced.

  4. Effect of surfactant for magnetic properties of iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Haracz, S. [Faculty of Chemistry, Adam Mickiewicz University, Umultowska 89B, 61-614 Poznań (Poland); Hilgendorff, M. [Freie Universität Berlin, Fachbereich Physik, Arnimalle 14, 14195 Berlin (Germany); Rybka, J.D. [Faculty of Chemistry, Adam Mickiewicz University, Umultowska 89B, 61-614 Poznań (Poland); Giersig, M. [Faculty of Chemistry, Adam Mickiewicz University, Umultowska 89B, 61-614 Poznań (Poland); Freie Universität Berlin, Fachbereich Physik, Arnimalle 14, 14195 Berlin (Germany)

    2015-12-01

    Highlights: • Dynamic behavior of magnetic nanoparticles. • Synthesis of iron oxide nanoparticles. • Effect of surfactant for magnetic properties. - Abstract: For different medical applications nanoparticles (NPs) with well-defined magnetic properties have to be used. Coating ligand can change the magnetic moment on the surface of nanostructures and therefore the magnetic behavior of the system. Here we investigated magnetic NPs in a size of 13 nm conjugated with four different kinds of surfactants. The surface anisotropy and the magnetic moment of the system were changed due to the presence of the surfactant on the surface of iron oxide NPs.

  5. Transient radiation effects in D.O.I. optical materials: Schott filter glass

    International Nuclear Information System (INIS)

    Simmons-Potter, K.

    1998-07-01

    Department of Energy and Defense Programs systems are becoming increasingly reliant on the use of optical technologies that must perform under a range of ionizing radiation environments. In particular, the radiation response of materials under consideration for applications in direct optical initiation (D.O.I.) schemes must be well characterized. In this report, transient radiation effects observed in Schott filter glass S-7010 are characterized. Under gamma exposure with 2 MeV photons in a 20--30 nsec pulse, the authors observe strong initial induced fluorescence in the red region of the spectrum followed by significant induced absorption over the same spectral region. Peak induced absorption coefficients of 0.113 cm -1 and 0.088 cm -1 were calculated at 800 nm and 660 nm respectively

  6. Transient radiation effects in D.O.I. optical materials: KD*P

    International Nuclear Information System (INIS)

    Simmons-Potter, K.

    1998-07-01

    Department of Energy and Defense Programs systems are becoming increasingly reliant on the use of optical technologies that must perform under a range of ionizing radiation environments. In particular, the radiation response of materials under consideration for applications in direct optical initiation (D.O.I.) schemes must be well characterized. In this report, transient radiation effects observed in a KD*P crystal are characterized. Under gamma exposure with 2 MeV photons in a 20--30 nsec pulse, the authors observe induced absorption at 1.06 microm that causes a peak decrease in overall sample transmittance of only 10%. This induced loss is seen to recover fully within the first 30 microsec

  7. Transient and cyclic effects on a PCM-cooled mobile device

    Directory of Open Access Journals (Sweden)

    Tso C.P.

    2015-01-01

    Full Text Available A mock handset with heat storage unit (HSU has been designed, fabricated, and experimented under various conditions to examine the effect of external heat sink on the handset’s transient temperature distribution, performance of the individual HSU under different power level and orientation, as well as under the more realistic cyclic heating. The cooling of the handset is through using a phase change material (PCM, n-eicosane, stored in the external HSU connected to the handset through a miniature heat pipe. The heat pipe channels the internal heat dissipation to the HSU where it is absorbed by the PCM. Results show that the temperature is significantly lowered with the PCM-based HSU.

  8. Effect of structure transformation on transient creep behavior of Al-Ag system

    Energy Technology Data Exchange (ETDEWEB)

    Deaf, G.H.; Yossef, S.B.; Mahmoud, M.A.; Graiss, G. [Ain Shams Univ., Cairo (Egypt). Dept. of Physics; Kenawy, M.A. [Ain Shams Univ., Cairo (Egypt). Womens Coll.

    1996-12-16

    The transient creep of Al-16 wt% Ag and Al-16 wt% Ag-0.1 wt% Zr solid solution alloys is investigated in the temperature range 428 to 673 K for various ageing times under constant load. The subsequent decrease and increase in the values of creep parameters n and {beta} with increasing ageing times and ageing temperatures has been explained on the basis of structure transformations occuring in Al-Ag alloys. It was found that the addition of Zr to Al-16 wt% Ag alloy accelerates the precipitation of GP zones, {gamma}`-phase, and {gamma}-phase. TEM investigations confirmed the above effects. The mean values of the activation energy of both alloys were found to be equal to that quoted for dislocation intersection. (orig.) 21 refs.

  9. Transient effects in SIMS analysis of Si with Cs sup + at high incidence angles Secondary ion yield variations

    CERN Document Server

    Heide, P A W

    2002-01-01

    Secondary ion mass spectrometry (SIMS) depth profile analysis of Si wafers using 1 keV Cs sup + primary ions at large incidence angles (80 deg. ) is plagued by unusually strong transient effects (variations in both sputter and ion yields). Analysis of a native oxide terminated Si wafer with and without the aid of an O sub 2 leak, and an Ar sup + pre-sputtered wafer revealed correlations between the implanted Cs content and various secondary ion intensities consistent with that expected from a resonance charge transfer process (that assumed by the electron tunneling model). Cs concentrations were defined through X-ray photoelectron spectroscopy of the sputtered surface from SIMS profiles terminated within the transient region. These scaled with the surface roughening occurring under these conditions and can be explained as resulting from the associated drop in sputter rates. An O induced transient effect from the native oxide was also identified. Characterization of these effects allowed the reconstruction of ...

  10. ANALYSIS AND SIMULATION OF MAIN MAGNET TRANSMISSION LINE EFFECT

    Energy Technology Data Exchange (ETDEWEB)

    ZHANG,W.; MARNERIS, I.; SANDBERG, J.

    2007-06-25

    A main magnet chain forms a pair of transmission lines. Pulse-reflection-caused voltage and current differentiation throughout the magnet chain can have adverse effect on main magnet field quality. This effect is associated with magnet system configuration, coupling efficiency, and parasitic parameters. A better understanding of this phenomenon will help us in new design and existing system upgrade. In this paper, we exam the transmission line effect due to different input functions as well as configuration, coupling, and other parameters.

  11. Effect of thermal transients on the hardness of Zircaloy fuel cladding

    International Nuclear Information System (INIS)

    Hobson, D.O.

    1976-06-01

    This study is directed toward the determination of the effects of annealing cycles with rapid heating rates, short hold times at specific temperatures, and rapid cool-down rates on the hardness of Zircaloy fuel cladding. These rapid annealing cycles are designed to provide preliminary annealing behavior data on Loss-of-Fluid-Test Reactor cladding samples. Information has been obtained on (1) the time dependence of the hardness as a function of annealing temperature, and (2) a correlation of single- and multitransient annealing relationships. Both single- and triple-cycle transients were used; four hold times at each of five maximum temperatures comprised the data set (each portion of the triple-cycle experiments had isothermal hold times equal to one-third of their analogous single-cycle times). It was found that there was little difference in the hardness response between single- and triple-cycle transients for a given total hold time at a particular temperature. Test temperatures range from 1000 to 1400 0 F (538 to 760 0 C) and hold times from 5 to 135 sec. The 1100 0 F (593 0 C) level was found to be the transition level for hardness changes, with shorter times (5 and 15 sec) effecting little or no hardness decrease and the longer times (45 and 135 sec) producing partially and fully annealed material, respectively. Temperatures equal to or greater than 1300 0 F (704 0 C) resulted in fully annealed material for all hold times. The 1000 0 F (538 0 C) tests produced no measurable softening

  12. Hysteresis effects in the cores of particle accelerator magnets

    CERN Document Server

    AUTHOR|(CDS)2086181; Schoerling, Daniel

    A study of the hysteresis effects in the cores of particle accelerator magnets has been performed in the framework of the work presented in this thesis. This study has been focused on normal conducting particle accelerator magnets whose cores are manufactured using ferromagnetic materials. The magnetic circuits have been modelled using the developed models: one model for the magnetic circuit and one for the magnetization of the material in the core. The parameters of the magnetic circuit model have been identified with the help of simulations which rely on the finite element method (Opera 3D), while the parameters of the magnetic hysteresis model have been identified through experimental measurements performed using a method developed in the framework of this work. The modelling results have been validated by means of experimental measurements performed on two magnets: one small size magnet which has been specifically designed and manufactured, and one magnet which is currently used in a particle accelerator ...

  13. State, space relay modeling and simulation using the electromagnetic Transients Program and its transient analysis of control systems capability

    International Nuclear Information System (INIS)

    Domijan, A.D. Jr.; Emami, M.V.

    1990-01-01

    This paper reports on a simulation of a MHO distance relay developed to study the effect of its operation under various system conditions. Simulation is accomplished using a state space approach and a modeling technique using ElectroMagnetic Transient Program (Transient Analysis of Control Systems). Furthermore, simulation results are compared with those obtained in another independent study as a control, to validate the results. A data code for the practical utilization of this simulation is given

  14. The use of single-crystal iron frames in transient field measurements

    International Nuclear Information System (INIS)

    Zalm, P.C.; Laan, J. van der; Middelkoop, G. van

    1979-01-01

    Single-crystal Fe frames have been investigated for use as a ferromagnetic backing in transient magnetic field experiments. For this purpose the surface magnetization as a function of applied magnetic field has been determined with the magneto-optical Kerr effect. The frames, which have two sides parallel to the crystal axis, can be fully magnetized at low external fields such that fringing fields are negligibly small. These single-crystal Fe backings have been used in several transient magnetic field experiments. Comparison of the measured precession angles with previous results, obtained in polycrystalline Fe foils at high external magnetic fields, shows that the single-crystal backings are satisfactory. After extended periods of heavy-ion bombardment the crystals exhibited no radiation damage effects. The absence of fringing fields leads to a reduction of a factor of four in the measuring time for transient field experiments. (Auth.)

  15. The effects of filament magnetization in superconducting magnets as calculated by POISSON

    International Nuclear Information System (INIS)

    Caspi, S.; Gilbert, W.S.; Helm, M.; Laslett, L.J.

    1986-09-01

    Magnetization of superconducting material can be introduced into POISSON through a field dependent permeability table (in the same way that iron characteristics are introduced). This can be done by representing measured magnetization data of the increasing and decreasing field by two independent B-γ curves (γ = 1/μ). Magnetization curves of this type were incorporated into the current regions of the program POISSON and their effect on the field coefficients observed. We have used this technique to calculate the effect of magnetization on the multipole coefficients of a SSC superconducting dipole magnet and to compare these coefficients with measured values

  16. Effect of axial stress on the transient mechanical response of 20%, cold-worked Type 316 stainless-steel cladding

    International Nuclear Information System (INIS)

    Yamada, H.

    1979-01-01

    To understand the effects of the fuel-cladding mechanical interaction on the failure of 20% cold-worked Type 316 stainless-steel cladding during anticipated nuclear reactor transients, the transient mechanical response of the cladding was investigated using a transient tube burst method at a heating rate of 5.6 0 C/s and axial-to-hoop-stress ratios in the range of 1/2 to 2. The failure temperatures were observed to remain essentially constant for the transient tests at axial-to-hoop-stress ratios between 1/2 and 1, but to decrease with an increase in axial-to-hoop-stress ratios above unity. The uniform diametral strains to failure were observed to decrease monotonically with an increase in axial-to-hoop-stress ratio from 1/2 to 2, and in general, the uniform axial strains to failure were observed to increase with an increase in axial-to-hoop-stress ratio. The fracture of the cladding during thermal transients was found to be strongly affected by the maximum principal stress but not by the effective stress

  17. The effects of air stoichiometry and air excess ratio on the transient response of a PEMFC under load change conditions

    International Nuclear Information System (INIS)

    Kim, Bosung; Cha, Dowon; Kim, Yongchan

    2015-01-01

    Highlights: • Effects of controlling parameters on the transient response of a PEMFC are studied. • The transient response is measured by varying air stoichiometry and air excess ratio. • Voltage drop, undershoot, and voltage fluctuation are analyzed under the load change. • Optimal air stoichiometry and air excess ratio are suggested for stable operation. - Abstract: The transient response of a proton exchange membrane fuel cell (PEMFC) is an important issue for transportation applications. The objective of this study is to investigate the effects of operating and controlling parameters on the transient response of a PEMFC for achieving more stable cell performance under load change conditions. The transient response of a PEMFC was measured and analyzed by varying air stoichiometry, air humidity, and air excess ratio (AER). The optimal air stoichiometry and AER were determined to minimize the voltage drop, undershoot, and voltage fluctuation under the load change, while maintaining high cell performance. Based on the present data, the optimal air stoichiometry was determined to be between 2.0 and 2.5, and the optimal AER was suggested to be between 1.65 and 2.0

  18. Magnetic Thermometer: Thermal effect on the Agglomeration of Magnetic Nanoparticles by Magnetic field

    Science.gov (United States)

    Jin, Daeseong; Kim, Hackjin

    2018-03-01

    We have investigated the agglomeration of magnetite nanoparticles in the aqueous solution under magnetic field by measuring temporal change of magnetic weight. The magnetic weight corresponds to the force due to the magnetization of magnetic materials. Superparamagnetic magnetite nanoparticles are synthesized and used in this work. When the aqueous solution of magnetite nanoparticle is placed under magnetic field, the magnetic weight of the sample jumps instantaneously by Neel and Brown mechanisms and thereafter increases steadily following a stretched exponential function as the nanoparticles agglomerate, which results from the distribution of energy barriers involved in the dynamics. Thermal motions of nanoparticles in the agglomerate perturb the ordered structure of the agglomerate to reduce the magnetic weight. Fluctuation of the structural order of the agglomerate by temperature change is much faster than the formation of agglomerate and explained well with the Boltzmann distribution, which suggests that the magnetic weight of the agglomerate works as a magnetic thermometer.

  19. Magnetic field and screening effects in condensed and ultradense matter

    International Nuclear Information System (INIS)

    Roussel, K.M.

    1974-01-01

    The investigations of three topics are presented: the origin of magnetic fields in white dwarfs and neutron stars, the detection of magnetic fields in white dwarfs, and screening effects due to free charged particles, particularly in semiconductors. (U.S.)

  20. PTA-1 computer program for treating pressure transients in hydraulic networks including the effect of pipe plasticity

    International Nuclear Information System (INIS)

    Youngdahl, C.K.; Kot, C.A.

    1977-01-01

    Pressure pulses in the intermediate sodium system of a liquid-metal-cooled fast breeder reactor, such as may originate from a sodium/water reaction in a steam generator, are propagated through the complex sodium piping network to system components such as the pump and intermediate heat exchanger. To assess the effects of such pulses on continued reliable operation of these components and to contribute to system designs which result in the mitigation of these effects, Pressure Transient Analysis (PTA) computer codes are being developed for accurately computing the transmission of pressure pulses through a complicated fluid transport system, consisting of piping, fittings and junctions, and components. PTA-1 provides an extension of the well-accepted and verified fluid hammer formulation for computing hydraulic transients in elastic or rigid piping systems to include plastic deformation effects. The accuracy of the modeling of pipe plasticity effects on transient propagation has been validated using results from two sets of Stanford Research Institute experiments. Validation of PTA-1 using the latter set of experiments is described briefly. The comparisons of PTA-1 computations with experiments show that (1) elastic-plastic deformation of LMFBR-type piping can have a significant qualitative and quantitative effect on pressure pulse propagation, even in simple systems; (2) classical fluid-hammer theory gives erroneous results when applied to situations where piping deforms plastically; and (3) the computational model incorporated in PTA-1 for predicting plastic deformation and its effect on transient propagation is accurate

  1. Ultrathin Interface Regime of Core-Shell Magnetic Nanoparticles for Effective Magnetism Tailoring.

    Science.gov (United States)

    Moon, Seung Ho; Noh, Seung-Hyun; Lee, Jae-Hyun; Shin, Tae-Hyun; Lim, Yongjun; Cheon, Jinwoo

    2017-02-08

    The magnetic exchange coupling interaction between hard and soft magnetic phases has been important for tailoring nanoscale magnetism, but spin interactions at the core-shell interface have not been well studied. Here, we systematically investigated a new interface phenomenon termed enhanced spin canting (ESC), which is operative when the shell thickness becomes ultrathin, a few atomic layers, and exhibits a large enhancement of magnetic coercivity (H C ). We found that ESC arises not from the typical hard-soft exchange coupling but rather from the large magnetic surface anisotropy (K S ) of the ultrathin interface. Due to this large increase in magnetism, ultrathin core-shell nanoparticles overreach the theoretical limit of magnetic energy product ((BH) max ) and exhibit one of the largest values of specific loss power (SLP), which testifies to their potential capability as an effective mediator of magnetic energy conversion.

  2. Magnetization, magnetic susceptibility, effective magnetic moment of Fe3+ ions in Bi25FeO39 ferrite

    International Nuclear Information System (INIS)

    Zatsiupa, A.A.; Bashkirov, L.A.; Troyanchuk, I.O.; Petrov, G.S.; Galyas, A.I.; Lobanovsky, L.S.; Truhanov, S.V.

    2014-01-01

    Magnetic susceptibility for ferrite Bi 25 FeO 39 is measured at 5–950 K in the magnetic field of 0.86 T. It is shown that Bi 25 FeO 39 is paramagnetic in the temperature range 5−950 K. The saturation magnetization is equal to 5.04μ B per formula unit at 5 K in a magnetic field of 10 T. It is found that at 5−300 K the effective magnetic moment of Fe 3+ ions in Bi 25 FeO 39 is equal to 5.82μ B . - Graphical abstract: The dependence of the magnetization (n, μ B ) on the magnetic field for one formula unit of Bi 25 FeO 39 at 5 K. - Highlights: • Magnetic susceptibility for Bi 25 FeO 39 is measured at 5–950 K in the magnetic field of 0.86 T. • It is shown that Bi 25 FeO 39 is paramagnetic in the temperature range 5−950 K. • The saturation magnetization is equal to 5.04μ B per formula unit at 5 K in a magnetic field of 10 T

  3. The effects of levosimendan on brain metabolism during initial recovery from global transient ischaemia/hypoxia

    Directory of Open Access Journals (Sweden)

    Roehl Anna B

    2012-08-01

    Full Text Available Abstract Backround Neuroprotective strategies after cardiopulmonary resuscitation are currently the focus of experimental and clinical research. Levosimendan has been proposed as a promising drug candidate because of its cardioprotective properties, improved haemodynamic effects in vivo and reduced traumatic brain injury in vitro. The effects of levosimendan on brain metabolism during and after ischaemia/hypoxia are unknown. Methods Transient cerebral ischaemia/hypoxia was induced in 30 male Wistar rats by bilateral common carotid artery clamping for 15 min and concomitant ventilation with 6% O2 during general anaesthesia with urethane. After 10 min of global ischaemia/hypoxia, the rats were treated with an i.v. bolus of 24 μg kg-1 levosimendan followed by a continuous infusion of 0.2 μg kg-1 min-1. The changes in the energy-related metabolites lactate, the lactate/pyruvate ratio, glucose and glutamate were monitored by microdialysis. In addition, the effects on global haemodynamics, cerebral perfusion and autoregulation, oedema and expression of proinflammatory genes in the neocortex were assessed. Results Levosimendan reduced blood pressure during initial reperfusion (72 ± 14 vs. 109 ± 2 mmHg, p = 0.03 and delayed flow maximum by 5 minutes (p = 0.002. Whereas no effects on time course of lactate, glucose, pyruvate and glutamate concentrations in the dialysate could be observed, the lactate/pyruvate ratio during initial reperfusion (144 ± 31 vs. 77 ± 8, p = 0.017 and the glutamate release during 90 minutes of reperfusion (75 ± 19 vs. 24 ± 28 μmol·L-1 were higher in the levosimendan group. The increased expression of IL-6, IL-1ß TNFα and ICAM-1, extend of cerebral edema and cerebral autoregulation was not influenced by levosimendan. Conclusion Although levosimendan has neuroprotective actions in vitro and on the spinal cord in vivo and has been shown to cross the blood–brain barrier, the present

  4. A Effect discussion of transient electromagnetic sounding technique in paleochannel-type sandstone-hosted uranium deposit

    International Nuclear Information System (INIS)

    Yang Jianchun; Fang Genxian; Yang Yaxin

    2003-01-01

    On the base of the application of transient electromagnetic technique of paleochannel-type sandstone-hosted uranium deposits in Tengchong region of Yunan Province, this paper analyses the detect example. It discusses the theory foundation of TEM, fieldwork means, data processing and interpret. By contrast with routine electricity farad, the transient electromagnetic technique have the special merit and favorable space resolve gender under conditions of intricacy terrain. This means can get good effect in detecting paleochannel-type sandstone-hosted uranium deposits space position. It is a good reference for other prospecting and exploration work

  5. Intense transient electric field sensor based on the electro-optic effect of LiNbO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qing, E-mail: yangqing@cqu.edu.cn; Sun, Shangpeng; Han, Rui; Sima, Wenxia; Liu, Tong [State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing, 400044 (China)

    2015-10-15

    Intense transient electric field measurements are widely applied in various research areas. An optical intense E-field sensor for time-domain measurements, based on the electro-optic effect of lithium niobate, has been studied in detail. Principles and key issues in the design of the sensor are presented. The sensor is insulated, small in size (65 mm × 15 mm × 15 mm), and suitable for high-intensity (<801 kV/m) electric field measurements over a wide frequency band (10 Hz–10 MHz). The input/output characteristics of the sensor were obtained and the sensor calibrated. Finally, an application using this sensor in testing laboratory lightning impulses and in measuring transient electric fields during switch-on of a disconnector confirmed that the sensor is expected to find widespread use in transient intense electric field measurement applications.

  6. Effects of turbine's selection on hydraulic transients in the long pressurized water conveyance system

    International Nuclear Information System (INIS)

    Zhou, J X; Hu, M; Cai, F L; Huang, X T

    2014-01-01

    For a hydropower station with longer water conveyance system, an optimum turbine's selection will be beneficial to its reliable and stable operation. Different optional turbines will result in possible differences of the hydraulic characteristics in the hydromechanical system, and have different effects on the hydraulic transients' analysis and control. Therefore, the premise for turbine's selection is to fully understand the properties of the optional turbines and their effects on the hydraulic transients. After a brief introduction of the simulation models for hydraulic transients' computation and stability analysis, the effects of hydraulic turbine's characteristics at different operating points on the hydro-mechanical system's free vibration analysis were theoretically investigated with the hydraulic impedance analysis of the hydraulic turbine. For a hydropower station with long water conveyance system, based on the detailed hydraulic transients' computation respectively for two different optional turbines, the effects of the turbine's selection on hydraulic transients were analyzed. Furthermore, considering different operating conditions for each turbine and the similar operating conditions for these two turbines, free vibration analysis was comprehensively carried out to reveal the effects of turbine's impedance on system's vibration characteristics. The results indicate that, respectively with two different turbines, most of the controlling parameters under the worst cases have marginal difference, and few shows obvious differences; the turbine's impedances under different operating conditions have less effect on the natural angular frequencies; different turbine's characteristics and different operating points have obvious effects on system's vibration stability; for the similar operating conditions of these two turbines, system's vibration characteristics are basically consistent with

  7. The effects of magnetic perturbations on plasma transport or is magnetic turbulence important in tokamaks?

    International Nuclear Information System (INIS)

    Wootton, A.J.

    1993-01-01

    A test particle model is verified and then used to interpret estimates of fast electron diffusivities in terms of magnetic fluctuation levels. The implied fluctuation levels are themselves interpreted with another verified model to predict electron thermal diffusivities. If the fast electron diffusivities represent local values, then the implied associated thermal transport is too small to explain experimental values. That is, magnetic fluctuations are not important. However, if the fast electron diffusivities represent effective values across mixed good (i.e. with no magnetic fluctuations) and bad (with magnetic fluctuations) surfaces then the implied magnetic fluctuation levels can influence electron thermal transport. (author)

  8. EFFECTS OF A TRANSIENT CANCER SCARE ON PROPERTY VALUES: IMPLICATIONS FOR RISK VALUATION AND THE VALUE OF LIFE. (R825173)

    Science.gov (United States)

    AbstractA transient cancer scare is presented as a rare opportunity to observe the effect of a perceived increase in risk on the price of residential property. The temporary nature of the perceived excess risk allows for the isolation of a risk premium from the change...

  9. Experimental investigation of the effect of titanium dioxide and barium titanate additives on DC transient currents in low density polyethylene

    DEFF Research Database (Denmark)

    Khalil, M.S; Henk, Peter O; Henriksen, Mogens

    1988-01-01

    The effect of titanium dioxide as a semiconductive additive and barium titanate as a highly polar additive on the DC transient currents in low-density polyethylene is investigated. Experiments were made using thick specimens under a high electric field (>25×106 V/m) and a constant temperature of 40...

  10. Liver fibrosis in type I Gaucher disease: magnetic resonance imaging, transient elastography and parameters of iron storage.

    Directory of Open Access Journals (Sweden)

    Anneloes E Bohte

    Full Text Available Long term liver-related complications of type-1 Gaucher disease (GD, a lysosomal storage disorder, include fibrosis and an increased incidence of hepatocellular carcinoma. Splenectomy has been implicated as a risk factor for the development of liver pathology in GD. High ferritin concentrations are a feature of GD and iron storage in Gaucher cells has been described, but iron storage in the liver in relation to liver fibrosis has not been studied. Alternatively, iron storage in GD may be the result of iron supplementation therapy or regular blood transfusions in patients with severe cytopenia. In this pilot study, comprising 14 type-1 GD patients (7 splenectomized, 7 non-splenectomized and 7 healthy controls, we demonstrate that liver stiffness values, measured by Transient Elastography and MR-Elastography, are significantly higher in splenectomized GD patients when compared with non-splenectomized GD patients (p = 0.03 and p = 0.01, respectively. Liver iron concentration was elevated (>60±30 µmol/g in 4 GD patients of whom 3 were splenectomized. No relationship was found between liver stiffness and liver iron concentration. HFE gene mutations were more frequent in splenectomized (6/7 than in non-splenectomized (2/7 participants (p = 0.10. Liver disease appeared more advanced in splenectomized than in non-splenectomized patients. We hypothesize a relationship with excessive hepatic iron accumulation in splenectomized patients. We recommend that all splenectomized patients, especially those with evidence of substantial liver fibrosis undergo regular screening for HCC, according to current guidelines.

  11. Magnetic resonance perfusion and diffusion imaging characteristics of transient bone marrow edema, avascular necrosis and subchondral insufficiency fractures of the proximal femur

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Dirk, E-mail: d.mueller@uk-koeln.de [Department of Radiology, University of Cologne (Germany); Department of Radiology, Technische Universität München (Germany); Schaeffeler, Christoph, E-mail: schaeffeler@me.com [Department of Radiology, Cantonal Hospital Graubuenden, Chur (Switzerland); Department of Radiology, Cantonal Hospital Graubuenden, Chur (Switzerland); Baum, Thomas, E-mail: thomas-baum@gmx.de [Department of Radiology, Technische Universität München (Germany); Walter, Flavia, E-mail: flavia_walter2000@yahoo.de [Department of Radiology, Technische Universität München (Germany); Rechl, Hans, E-mail: rechl@tum.de [Department of Orthopaedics, Technische Universität München (Germany); Rummeny, Ernst J., E-mail: rummeny@tum.de [Department of Radiology, Technische Universität München (Germany); Woertler, Klaus, E-mail: klaus.woertler@tum.de [Department of Radiology, Technische Universität München (Germany)

    2014-10-15

    Highlights: • DCE-MRI may add information to the pathophysiology of bone marrow edema (BME) of the proximal femur. • Patients with transient bone marrow edema (TBME) or subchondral insufficiency fractures (SIF) and avascular osteonecrosis (AVN) showed different MR perfusion patterns. • Perfusion characteristics suggest different pathophysiology for AVN compared with TBME or SIF. • Diffusion weighted imaging (DWI) was not able to discriminate necrotic from edematous bone marrow. • DWI is of limited value to evaluate BME of the proximal femur. - Abstract: Purpose: To evaluate magnetic resonance (MR) perfusion and diffusion imaging characteristics in patients with transient bone marrow edema (TBME), avascular necrosis (AVN), or subchondral insufficiency fractures (SIF) of the proximal femur. Materials and methods: 29 patients with painful hip and bone marrow edema pattern of the proximal femur on non-contrast MR imaging were examined using diffusion-weighted and dynamic gadolinium-enhanced sequences. Apparent diffusion coefficients (ADCs) and perfusion parameters were calculated for different regions of the proximal femur. Regional distribution and differences in ADC values and perfusion parameters were evaluated. Results: Seven patients presented with TBME, 15 with AVN and seven with SIF of the proximal femur. Perfusion imaging showed significant differences for maximum enhancement values (E{sub max}), slope (E{sub slope}) and time to peak (TTP) between the three patient groups (p < 0.05). In contrast, no significant differences for ADC values were calculated when comparing TBME, AVN, and SIF patients. Conclusion: Diffusion weighted imaging of bone marrow of the proximal femur did not show significant differences between patients with TBME, AVN or SIF. In contrast, MR perfusion imaging demonstrated significant differences for the different patient groups and may as a complementary imaging technique add information to the understanding of the pathophysiology

  12. Magnetic resonance perfusion and diffusion imaging characteristics of transient bone marrow edema, avascular necrosis and subchondral insufficiency fractures of the proximal femur

    International Nuclear Information System (INIS)

    Mueller, Dirk; Schaeffeler, Christoph; Baum, Thomas; Walter, Flavia; Rechl, Hans; Rummeny, Ernst J.; Woertler, Klaus

    2014-01-01

    Highlights: • DCE-MRI may add information to the pathophysiology of bone marrow edema (BME) of the proximal femur. • Patients with transient bone marrow edema (TBME) or subchondral insufficiency fractures (SIF) and avascular osteonecrosis (AVN) showed different MR perfusion patterns. • Perfusion characteristics suggest different pathophysiology for AVN compared with TBME or SIF. • Diffusion weighted imaging (DWI) was not able to discriminate necrotic from edematous bone marrow. • DWI is of limited value to evaluate BME of the proximal femur. - Abstract: Purpose: To evaluate magnetic resonance (MR) perfusion and diffusion imaging characteristics in patients with transient bone marrow edema (TBME), avascular necrosis (AVN), or subchondral insufficiency fractures (SIF) of the proximal femur. Materials and methods: 29 patients with painful hip and bone marrow edema pattern of the proximal femur on non-contrast MR imaging were examined using diffusion-weighted and dynamic gadolinium-enhanced sequences. Apparent diffusion coefficients (ADCs) and perfusion parameters were calculated for different regions of the proximal femur. Regional distribution and differences in ADC values and perfusion parameters were evaluated. Results: Seven patients presented with TBME, 15 with AVN and seven with SIF of the proximal femur. Perfusion imaging showed significant differences for maximum enhancement values (E max ), slope (E slope ) and time to peak (TTP) between the three patient groups (p < 0.05). In contrast, no significant differences for ADC values were calculated when comparing TBME, AVN, and SIF patients. Conclusion: Diffusion weighted imaging of bone marrow of the proximal femur did not show significant differences between patients with TBME, AVN or SIF. In contrast, MR perfusion imaging demonstrated significant differences for the different patient groups and may as a complementary imaging technique add information to the understanding of the pathophysiology of

  13. Modeling demagnetization effects in permanent magnet synchronous machines

    NARCIS (Netherlands)

    Kral, C.; Sprangers, R.L.J.; Waarma, J.; Haumer, A.; Winter, O.; Lomonova, E.

    2010-01-01

    This paper presents a permanent magnet model which takes temperature dependencies and demagnetization effects into account. The proposed model is integrated into a magnetic fundamental wave machine model using the model- ing language Modelica. For different rotor types permanent magnet models are

  14. effects of magnetically treated water on germination and growth

    African Journals Online (AJOL)

    Toshiba

    This study was conducted to evaluate the effect of magnetically treated water on the survival ... density used was 719 gauss (G) measured inside the pipe. ... of the meristem cells and chlorophyll were ..... Table 4 Tomato stem girth irrigated with magnetically and non–magnetically treated .... Electrical Separation, 7: 77-107.

  15. Studies on an Electromagnetic Transient Model of Offshore Wind Turbines and Lightning Transient Overvoltage Considering Lightning Channel Wave Impedance

    Directory of Open Access Journals (Sweden)

    Li Zhang

    2017-12-01

    Full Text Available In recent years, with the rapid development of offshore wind turbines (WTs, the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs, the influencing factors and the response rules of transient overvoltage are analyzed. In this paper, a new integrated electromagnetic transient model of offshore WTs is established by using the numerical calculation method of the electromagnetic field first. Then, based on the lightning model and considering the impedance of the lightning channel, the transient overvoltage of lightning is analyzed. Last, the electromagnetic transient model of offshore WTs is simulated and analyzed by using the alternative transients program electro-magnetic transient program (ATP-EMTP software. The influence factors of lightning transient overvoltage are studied. The main influencing factors include the sea depth, the blade length, the tower height, the lightning flow parameters, the lightning strike point, and the blade rotation position. The simulation results show that the influencing factors mentioned above have different effects on the lightning transient overvoltage. The results of the study have some guiding significance for the design of the lightning protection of the engine room.

  16. Effective field theory for magnetic compactifications

    Energy Technology Data Exchange (ETDEWEB)

    Buchmuller, Wilfried; Dierigl, Markus [Deutsches Elektronen-Synchrotron DESY,22607 Hamburg (Germany); Dudas, Emilian [Centre de Physique Théorique, École Polytechnique, CNRS, Université Paris-Saclay,F-91128 Palaiseau (France); Schweizer, Julian [Deutsches Elektronen-Synchrotron DESY,22607 Hamburg (Germany)

    2017-04-10

    Magnetic flux plays an important role in compactifications of field and string theories in two ways, it generates a multiplicity of chiral fermion zero modes and it can break supersymmetry. We derive the complete four-dimensional effective action for N=1 supersymmetric Abelian and non-Abelian gauge theories in six dimensions compactified on a torus with flux. The effective action contains the tower of charged states and it accounts for the mass spectrum of bosonic and fermionic fields as well as their level-dependent interactions. This allows us to compute quantum corrections to the mass and couplings of Wilson lines. We find that the one-loop corrections vanish, contrary to the case without flux. This can be traced back to the spontaneous breaking of symmetries of the six-dimensional theory by the background gauge field, with the Wilson lines as Goldstone bosons.

  17. Transient heating effects on tungsten: Ablation of Be layers and enhanced fuzz growth

    International Nuclear Information System (INIS)

    Yu, J.H.; Baldwin, M.J.; Doerner, R.P.; Dittmar, T.; Hakola, A.; Höschen, T.; Likonen, J.; Nishijima, D.; Toudeshki, H.H.

    2015-01-01

    A pulsed laser in the PISCES-B facility is used to simulate transient heating events such as ELMs and disruptions on W. The first study of enhanced nano-scale W tendril growth (“fuzz”) due to cyclic fast transient heating of W exposed to low energy (E He+ ∼ 30 eV) He + ions is presented. Fuzz due to transient heating is up to ∼10× thicker than the steady state fuzz thickness with no laser heating. A general thermal activation model yields higher values for the activation energy and pre-exponential factor than previously reported in steady state experiments with E He+ ∼ 60 eV. Transient heating of W exposed to D plasma with Be seeding shows that the removal threshold of Be follows simple energy considerations based on the heat of formation of Be

  18. Effect of state feedback coupling on the transient performance of voltage source inverters with LC filter

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; Antonio DeSouza Ribeiro, Luiz

    2016-01-01

    State feedback coupling between the capacitor voltage and inductor current deteriorates notably the performance during transients of voltage and current regulators in stand-alone systems based on voltage source inverters. A decoupling technique is proposed, considering the limitations introduced...

  19. Modeling of transient ionizing radiation effects in bipolar devices at high dose-rates

    International Nuclear Information System (INIS)

    FJELDLY, T.A.; DENG, Y.; SHUR, M.S.; HJALMARSON, HAROLD P.; MUYSHONDT, ARNOLDO

    2000-01-01

    To optimally design circuits for operation at high intensities of ionizing radiation, and to accurately predict their a behavior under radiation, precise device models are needed that include both stationary and dynamic effects of such radiation. Depending on the type and intensity of the ionizing radiation, different degradation mechanisms, such as photoelectric effect, total dose effect, or single even upset might be dominant. In this paper, the authors consider the photoelectric effect associated with the generation of electron-hole pairs in the semiconductor. The effects of low radiation intensity on p-II diodes and bipolar junction transistors (BJTs) were described by low-injection theory in the classical paper by Wirth and Rogers. However, in BJTs compatible with modem integrated circuit technology, high-resistivity regions are often used to enhance device performance, either as a substrate or as an epitaxial layer such as the low-doped n-type collector region of the device. Using low-injection theory, the transient response of epitaxial BJTs was discussed by Florian et al., who mainly concentrated on the effects of the Hi-Lo (high doping - low doping) epilayer/substrate junction of the collector, and on geometrical effects of realistic devices. For devices with highly resistive regions, the assumption of low-level injection is often inappropriate, even at moderate radiation intensities, and a more complete theory for high-injection levels was needed. In the dynamic photocurrent model by Enlow and Alexander. p-n junctions exposed to high-intensity radiation were considered. In their work, the variation of the minority carrier lifetime with excess carrier density, and the effects of the ohmic electric field in the quasi-neutral (q-n) regions were included in a simplified manner. Later, Wunsch and Axness presented a more comprehensive model for the transient radiation response of p-n and p-i-n diode geometries. A stationary model for high-level injection in p

  20. Effects of geometry in itinerant electron magnets

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H [Graduate School of Material Science, University of Hyogo, Kamigori, Ako-gun, Hyogo 678-1297 (Japan); Muro, Y [Graduate School of Material Science, University of Hyogo, Kamigori, Ako-gun, Hyogo 678-1297 (Japan); Kohara, T [Graduate School of Material Science, University of Hyogo, Kamigori, Ako-gun, Hyogo 678-1297 (Japan); Shiga, M [Department of Materials Science and Engineering, Kyoto University, Kyoto 606-8501 (Japan)

    2007-04-11

    The magnetism of quasi-one-dimensional itinerant electron magnets RMn{sub 4}Al{sub 8} is compared with that of the typical frustrated itinerant electron magnet YMn{sub 2}. The possible formation and observation of the spin pseudogap are discussed in connection with the spin-liquid state in strongly correlated itinerant electron systems.

  1. Effect of automatic recirculation flow control on the transient response for Lungmen ABWR plant

    Energy Technology Data Exchange (ETDEWEB)

    Tzang, Y.-C., E-mail: yctzang@aec.gov.t [National Tsing Hua University, Department of Engineering and System Science, Hsinchu 30013, Taiwan (China); Chiang, R.-F.; Ferng, Y.-M.; Pei, B.-S. [National Tsing Hua University, Department of Engineering and System Science, Hsinchu 30013, Taiwan (China)

    2009-12-15

    In this study the automatic mode of the recirculation flow control system (RFCS) for the Lungmen ABWR plant has been modeled and incorporated into the basic RETRAN-02 system model. The integrated system model is then used to perform the analyses for the two transients in which the automatic RFCS is involved. The two transients selected are: (1) one reactor internal pump (RIP) trip, and (2) loss of feedwater heating. In general, the integrated system model can predict well the response of key system parameters, including neutron flux, steam dome pressure, heat flux, RIP flow, core inlet flow, feedwater flow, steam flow, and reactor water level. The transients are also analyzed for manual RFCS case, between the automatic RFCS and the manual RFCS cases, comparisons of the transient response for the key system parameter show that the difference of transient response can be clearly identified. Also, the results show that the DELTACPR (delta critical power ratio) for the transients analyzed may not be less limiting for the automatic RFCS case under certain combination of control system settings.

  2. Particle size, magnetic field, and blood velocity effects on particle retention in magnetic drug targeting.

    Science.gov (United States)

    Cherry, Erica M; Maxim, Peter G; Eaton, John K

    2010-01-01

    A physics-based model of a general magnetic drug targeting (MDT) system was developed with the goal of realizing the practical limitations of MDT when electromagnets are the source of the magnetic field. The simulation tracks magnetic particles subject to gravity, drag force, magnetic force, and hydrodynamic lift in specified flow fields and external magnetic field distributions. A model problem was analyzed to determine the effect of drug particle size, blood flow velocity, and magnetic field gradient strength on efficiency in holding particles stationary in a laminar Poiseuille flow modeling blood flow in a medium-sized artery. It was found that particle retention rate increased with increasing particle diameter and magnetic field gradient strength and decreased with increasing bulk flow velocity. The results suggest that MDT systems with electromagnets are unsuitable for use in small arteries because it is difficult to control particles smaller than about 20 microm in diameter.

  3. Dynamo Effects in Magnetized Ideal Plasma Cosmologies

    Science.gov (United States)

    Kleidis, Kostas; Kuiroukidis, Apostolos; Papadopoulos, Demetrios; Vlahos, Loukas

    The excitation of cosmological perturbations in an anisotropic cosmological model and in the presence of a homogeneous magnetic field has been studied, using the ideal magnetohydrodynamic (MHD) equations. In this case, the system of partial differential equations which governs the evolution of the magnetized cosmological perturbations can be solved analytically. Our results verify that fast-magnetosonic modes propagating normal to the magnetic field, are excited. But, what is most important, is that, at late times, the magnetic-induction contrast (δB/B) grows, resulting in the enhancement of the ambient magnetic field. This process can be particularly favored by condensations, formed within the plasma fluid due to gravitational instabilities.

  4. Measurements of Bauschinger effect and transient behavior of a quenched and partitioned advanced high strength steel

    International Nuclear Information System (INIS)

    Zang, Shun-lai; Sun, Li; Niu, Chao

    2013-01-01

    In recent decades, the needs for new advanced high strength steels (AHSS) with high ductility and strength have rapidly increased to achieve the targets of more fuel-efficient and safer vehicles in automotive industry. However, several undesirable phenomena are experimentally observed during the forming of such materials, particularly with complex loading and large plastic deformation. Springback is one of the most important problems that should be compensated in sheet metal forming process. In this paper, we investigated the hardening behavior of a Q and P (quench and partitioning) steel designated by QP980CR, which is a new third generation advance high strength steel, from the Baosteel Group Corp. in Shanghai, China. The uni-axial tensile and cyclic simple shear tests were conducted. The uni-axial tensile tests were performed on the specimens at 0°, 45° and 90° to rolling direction (RD). The flow stress and transverse strain evolution were obtained in view of the digital image correlation (DIC) measurement. The plastic anisotropy was optimized from the uni-axial tensile tests and thereafter incorporated into the simulations of cyclic simple shear tests. The cyclic simple shear tests were conducted with three prestrains to measure the Bauschinger effect, transient behavior and permanent softening, and to determine the material parameters of the combined isotropic-kinematic hardening model

  5. Measurements of Bauschinger effect and transient behavior of a quenched and partitioned advanced high strength steel

    Energy Technology Data Exchange (ETDEWEB)

    Zang, Shun-lai, E-mail: shawn@mail.xjtu.edu.cn [School of Mechanical Engineering, Xi' an Jiaotong University, No. 28, Xianning Road, Xi' an, Shaanxi (China); Sun, Li [Manufacturing Process Research, General Motors China Science Lab, No. 56, Jinwan Road, Shanghai (China); Niu, Chao [School of Mechanical Engineering, Xi' an Jiaotong University, No. 28, Xianning Road, Xi' an, Shaanxi (China)

    2013-12-01

    In recent decades, the needs for new advanced high strength steels (AHSS) with high ductility and strength have rapidly increased to achieve the targets of more fuel-efficient and safer vehicles in automotive industry. However, several undesirable phenomena are experimentally observed during the forming of such materials, particularly with complex loading and large plastic deformation. Springback is one of the most important problems that should be compensated in sheet metal forming process. In this paper, we investigated the hardening behavior of a Q and P (quench and partitioning) steel designated by QP980CR, which is a new third generation advance high strength steel, from the Baosteel Group Corp. in Shanghai, China. The uni-axial tensile and cyclic simple shear tests were conducted. The uni-axial tensile tests were performed on the specimens at 0°, 45° and 90° to rolling direction (RD). The flow stress and transverse strain evolution were obtained in view of the digital image correlation (DIC) measurement. The plastic anisotropy was optimized from the uni-axial tensile tests and thereafter incorporated into the simulations of cyclic simple shear tests. The cyclic simple shear tests were conducted with three prestrains to measure the Bauschinger effect, transient behavior and permanent softening, and to determine the material parameters of the combined isotropic-kinematic hardening model.

  6. Transient effects during erosion of WN by deuterium ions studied with the quartz crystal microbalance technique

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Bernhard M., E-mail: berger@iap.tuwien.ac.at [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Stadlmayr, Reinhard [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Meisl, Gerd [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Čekada, Miha [Jožef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Eisenmenger-Sittner, Christoph [Institute of Solid State Physics, TU Wien, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Schwarz-Selinger, Thomas [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Aumayr, Friedrich, E-mail: aumayr@iap.tuwien.ac.at [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria)

    2016-09-01

    Transient effects during erosion of polycrystalline tungsten-nitride (WN) films by mono-energetic deuterium projectiles are studied using a quartz crystal microbalance technique. The evolution of the mass removal rate of a 360 nm thin WN film under 500 eV/D and 1000 eV/D bombardment is investigated at a temperature of 465 K in situ and in real-time as a function of the deuterium fluence. The measurements are performed at a typical flux of 10{sup 18} m{sup −2} s{sup −1}. A strong dependency of the observed mass change rate on the deuterium fluence is found. The mass loss is initially higher than for pure tungsten (W) and drops with fluence, finally reaching the same steady state value as for pure W sputtering. Steady state surface conditions are obtained at a fluence of about 0.2 × 10{sup 23} D/m{sup 2} for 500 eV/D and 0.6 × 10{sup 23} D/m{sup 2} for 1000 eV/D. SDTrimSP simulations indicate a preferential removal of N and a corresponding W enrichment of the surface.

  7. Effect of Transient Treatment with Propylthiouracil on Some Reproduction Traits and Live Weight of Japanese Quails

    Directory of Open Access Journals (Sweden)

    B Sogut

    Full Text Available ABSTRACT This study was conducted to investigate the effects of transient treatment with propylthiouracil (PTU on some reproduction traits and live weight of quails. The trial lasted 8 weeks. To accomplish this goal, 700 1-day-old quail chicks were used, randomly divided into 8 groups. PTU was added to feed by 0.1% and 0.5% /wt. The first 4 groups had 0.5% PTU at the age of 2-4, 4-6, 6-8 and 2-8 wk., respectively. The 5 th, 6 th and 7 th groups had 0.1% PTU at the age of 2-4, 4-6 and 6-8 wk., respectively, and the 8 th group was the control with no PTU. Quails were bled at 60 days of age. Then right and left testes were taken out and weighed. At the end of the trail, least square means of the live weight of the treatment groups were higher than the control (p<0.05. Similar results (p<0.05 were observed for testis weight, testis diameter and fertility rate. As a result, it can be said that the inclusion of PTU in quail rations positively affects the live weight and reproduction traits of quails.

  8. Effect of magnetic field on the physical properties of water

    Science.gov (United States)

    Wang, Youkai; Wei, Huinan; Li, Zhuangwen

    2018-03-01

    In this study, the effect of magnetic field (MF) on the partial physical properties of water are reported, tap water (TW) and 4 types of magnetized water (MW) were measured in the same condition. It was found that the properties of TW were changed following the MF treatment, shown as the increase of evaporation amount, the decrease of specific heat and boiling point after magnetization, the changes depend on the magnetization effect. In addition, magnetic field strength (MFS) has a marked influence on the magnetization effect, the optimal magnetizing condition was determined as the MFS of 300 mT. The findings of this study offered a facile approach to improve cooling and power generation efficiency in industrial.

  9. Measurement of the magnetic moment of the 21+ state of 72Zn via extension of the high-velocity transient-field method

    International Nuclear Information System (INIS)

    Fiori, E.

    2010-12-01

    Magnetic moments can provide deep insight for nuclear structure and of the wave function composition, particularly when the single particle character of the nucleus is dominating. For this reason, the magnetic moment of the first excited state of the radioactive neutron-rich 72 Zn was measured at the GANIL facility (Caen, France). The result of the experiment confirmed the trend predicted by the shell model calculations, even if the error on the measurement did not allow for a rigorous constraint of the theories. The measurement was performed using the transient field (TF) technique and the nuclei of interest were produced in a fragmentation reaction. Before this experiment, the high-velocity TF (HVTF) technique had been used only with projectile up to Z = 24. It was the first time that a magnetic moment of an heavy ion with Z > 24 was measured in the high velocity regime. To further develop the technique and to gather information about the hyperfine interaction between the polarized electrons and the nucleons, two experiments were performed at LNS (Catania, Italy). In this thesis the development of the high-velocity TF technique for the experiments on g(2 + ; 72 Zn) and field strength B TF (Kr, Ge) is presented. The analysis of the results and their interpretation is then discussed. It was demonstrated that the HVTF technique, combined with Coulomb excitation, can be used for the measurement of g-factors of very short-lived states, with lifetimes of the order of tens of ps and lower, of heavy ions (A ∼ 80) traveling with intermediate relativistic speeds, β ∼ 0.25. The standard TF technique at low velocities (a few percent of the speed of light) has been used for a long time to provide the strong magnetic field necessary for the measurement of g-factors of very short-lived states. The breakthrough of the present development is the different velocity regime of the higher mass projectile under which the experiment is carried out

  10. Transient inhibitory effect of methoxychlor on testicular steroidogenesis in rat: an in vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Vaithinathan, S.; Saradha, B.; Mathur, P.P. [Pondicherry University, Department of Biochemistry and Molecular Biology, School of Life Sciences, Pondicherry (India)

    2008-11-15

    Methoxychlor, an organochlorine pesticide, has been reported to induce reproductive abnormalities in male reproductive tract. To get more insight into the mechanism(s) of gonadal toxicity provoked by methoxychlor, we investigated whether treatment with methoxychlor at low observed adverse effect level (LOAEL) would alter the activities of steroidogenic enzymes such as {delta}{sup 5}3{beta}-hydroxysteroid dehydrogenase (3{beta}-HSD) and {delta}{sup 5}17{beta}-hydroxysteroid dehydrogenase (17{beta}-HSD), the expression levels of steroidogenic acute regulatory (StAR) protein and androgen binding protein (ABP) in the testis of adult male rats. The experimental rats were exposed to a single dose of methoxychlor (50 mg/kg body weight) orally. The rats were killed at 0, 3, 6, 12, 24 and 72 h following treatment using anesthetic ether and testes were collected, processed and used to measure the activities of 3{beta}-HSD, 17{beta}-HSD, levels of hydrogen peroxide produced and the expression levels of StAR protein, and ABP. Methoxychlor administration resulted in a sequential reduction in the expression of StAR protein and activities of 3{beta}-HSD, 17{beta}-HSD with concomitant increase in the levels of hydrogen peroxide in the testis. These changes were significant between 6-12 h following treatment. The levels of ABP declined at 6-12 h following exposure to methoxychlor. The present study demonstrates transient effect of methoxychlor at LOAEL on testicular steroidogenesis and the possible role of hydrogen peroxide in mediating these effects. (orig.)

  11. Surface cracking and melting of different tungsten grades under transient heat and particle loads in a magnetized coaxial plasma gun

    Science.gov (United States)

    Kikuchi, Y.; Sakuma, I.; Iwamoto, D.; Kitagawa, Y.; Fukumoto, N.; Nagata, M.; Ueda, Y.

    2013-07-01

    Surface damage of pure tungsten (W), W alloys with 2 wt.% tantalum (W-Ta) and vacuum plasma spray (VPS) W coating on a reduced activation material of ferritic steel (F82H) due to repetitive ELM-like pulsed (˜0.3 ms) deuterium plasma irradiation has been investigated by using a magnetized coaxial plasma gun. Surface cracks appeared on a pure W sample exposed to 10 plasma pulses of ˜0.3 MJ m-2, while a W-Ta sample did not show surface cracks with similar pulsed plasma irradiation. The energy density threshold for surface cracking was significantly increased by the existence of the alloying element of tantalum. No surface morphology change of a VPS W coated F82H sample was observed under 10 plasma pulses of ˜0.3 MJ m-2, although surface melting and cracks in the resolidification layer occurred at higher energy density of ˜0.9 MJ m-2. There was no indication of exfoliation of the W coating from the substrate of F82H after the pulsed plasma exposures.

  12. Surface cracking and melting of different tungsten grades under transient heat and particle loads in a magnetized coaxial plasma gun

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Y., E-mail: ykikuchi@eng.u-hyogo.ac.jp [Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji, Hyogo 671-2280 (Japan); Sakuma, I.; Iwamoto, D.; Kitagawa, Y.; Fukumoto, N.; Nagata, M. [Graduate School of Engineering, University of Hyogo, 2167 Shosha, Himeji, Hyogo 671-2280 (Japan); Ueda, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871 (Japan)

    2013-07-15

    Surface damage of pure tungsten (W), W alloys with 2 wt.% tantalum (W–Ta) and vacuum plasma spray (VPS) W coating on a reduced activation material of ferritic steel (F82H) due to repetitive ELM-like pulsed (∼0.3 ms) deuterium plasma irradiation has been investigated by using a magnetized coaxial plasma gun. Surface cracks appeared on a pure W sample exposed to 10 plasma pulses of ∼0.3 MJ m{sup −2}, while a W–Ta sample did not show surface cracks with similar pulsed plasma irradiation. The energy density threshold for surface cracking was significantly increased by the existence of the alloying element of tantalum. No surface morphology change of a VPS W coated F82H sample was observed under 10 plasma pulses of ∼0.3 MJ m{sup −2}, although surface melting and cracks in the resolidification layer occurred at higher energy density of ∼0.9 MJ m{sup −2}. There was no indication of exfoliation of the W coating from the substrate of F82H after the pulsed plasma exposures.

  13. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  14. 3-D Forward modeling of Induced Polarization Effects of Transient Electromagnetic Method

    Science.gov (United States)

    Wu, Y.; Ji, Y.; Guan, S.; Li, D.; Wang, A.

    2017-12-01

    In transient electromagnetic (TEM) detection, Induced polarization (IP) effects are so important that they cannot be ignored. The authors simulate the three-dimensional (3-D) induced polarization effects in time-domain directly by applying the finite-difference time-domain method (FDTD) based on Cole-Cole model. Due to the frequency dispersion characteristics of the electrical conductivity, the computations of convolution in the generalized Ohm's law of fractional order system makes the forward modeling particularly complicated. Firstly, we propose a method to approximate the fractional order function of Cole-Cole model using a lower order rational transfer function based on error minimum theory in the frequency domain. In this section, two auxiliary variables are introduced to transform nonlinear least square fitting problem of the fractional order system into a linear programming problem, thus avoiding having to solve a system of equations and nonlinear problems. Secondly, the time-domain expression of Cole-Cole model is obtained by using Inverse Laplace transform. Then, for the calculation of Ohm's law, we propose an e-index auxiliary equation of conductivity to transform the convolution to non-convolution integral; in this section, the trapezoid rule is applied to compute the integral. We then substitute the recursion equation into Maxwell's equations to derive the iterative equations of electromagnetic field using the FDTD method. Finally, we finish the stimulation of 3-D model and evaluate polarization parameters. The results are compared with those obtained from the digital filtering solution of the analytical equation in the homogeneous half space, as well as with the 3-D model results from the auxiliary ordinary differential equation method (ADE). Good agreements are obtained across the three methods. In terms of the 3-D model, the proposed method has higher efficiency and lower memory requirements as execution times and memory usage were reduced by 20

  15. Excitation of transient lobe cell convection and auroral arc at the cusp poleward boundary during a transition of the interplanetary magnetic field from south to north

    Directory of Open Access Journals (Sweden)

    P. E. Sandholt

    2001-05-01

    Full Text Available We document the activation of transient polar arcs emanating from the cusp within a 15 min long intermediate phase during the transition from a standard two-cell convection pattern, representative of a strongly southward interplanetary magnetic field (IMF, to a "reverse" two-cell pattern, representative of strongly northward IMF conditions. During the 2–3 min lifetime of the arc, its base in the cusp, appearing as a bright spot, moved eastward toward noon by ~ 300 km. As the arc moved, it left in its "wake" enhanced cusp precipitation. The polar arc is a tracer of the activation of a lobe convection cell with clockwise vorticity, intruding into the previously established large-scale distorted two-cell pattern, due to an episode of localized lobe reconnection. The lobe cell gives rise to strong flow shear (converging electric field and an associated sheet of outflowing field-aligned current, which is manifested by the polar arc. The enhanced cusp precipitation represents, in our view, the ionospheric footprint of the lobe reconnection process.Key words. Magnetospheric physics (auroral phenomena; magnetopause, cusp, and boundary layers; plasma convection

  16. Using nuclear magnetic resonance and transient electromagnetics to characterise water distribution beneath an ice covered volcanic crater: the case of Sherman Crater Mt. Baker Washington.

    Science.gov (United States)

    Irons, Trevor P.; Martin, Kathryn; Finn, Carol A.; Bloss, Benjamin; Horton, Robert J.

    2014-01-01

    Surface and laboratory Nuclear Magnetic Resonance (NMR) measurements combined with transient electromagnetic (TEM) data are powerful tools for subsurface water detection. Surface NMR (sNMR) and TEM soundings, laboratory NMR, complex resistivity, and X-Ray Diffraction (XRD) analysis were all conducted to characterise the distribution of water within Sherman Crater on Mt. Baker, WA. Clay rich rocks, particularly if water saturated, can weaken volcanoes, thereby increasing the potential for catastrophic sector collapses that can lead to far-travelled, destructive debris flows. Detecting the presence and volume of shallow groundwater is critical for evaluating these landslide hazards. The TEM data identified a low resistivity layer (conditions which would allow for sNMR detection of the clay layer are investigated. Using current instrumentation the combined analysis of the TEM and sNMR data allow for valuable characterisation of the groundwater system in the crater. The sNMR is able to reduce the uncertainty of the TEM in regards to the presence of a bulk water layer, a valuable piece of information in hazard assessment.

  17. Effects of a parallel resistor on electrical characteristics of a piezoelectric transformer in open-circuit transient state.

    Science.gov (United States)

    Chang, Kuo-Tsai

    2007-01-01

    This paper investigates electrical transient characteristics of a Rosen-type piezoelectric transformer (PT), including maximum voltages, time constants, energy losses and average powers, and their improvements immediately after turning OFF. A parallel resistor connected to both input terminals of the PT is needed to improve the transient characteristics. An equivalent circuit for the PT is first given. Then, an open-circuit voltage, involving a direct current (DC) component and an alternating current (AC) component, and its related energy losses are derived from the equivalent circuit with initial conditions. Moreover, an AC power control system, including a DC-to-AC resonant inverter, a control switch and electronic instruments, is constructed to determine the electrical characteristics of the OFF transient state. Furthermore, the effects of the parallel resistor on the transient characteristics at different parallel resistances are measured. The advantages of adding the parallel resistor also are discussed. From the measured results, the DC time constant is greatly decreased from 9 to 0.04 ms by a 10 k(omega) parallel resistance under open output.

  18. Numerical evidence of chiral magnetic effect in lattice gauge theory

    International Nuclear Information System (INIS)

    Buividovich, P. V.; Chernodub, M. N.; Luschevskaya, E. V.; Polikarpov, M. I.

    2009-01-01

    The chiral magnetic effect is the generation of electric current of quarks along an external magnetic field in the background of topologically nontrivial gluon fields. There is recent evidence that this effect is observed by the STAR Collaboration in heavy-ion collisions at the Relativistic Heavy Ion Collider. In our paper we study qualitative signatures of the chiral magnetic effect using quenched lattice simulations. We find indications that the electric current is indeed enhanced in the direction of the magnetic field both in equilibrium configurations of the quantum gluon fields and in a smooth gluon background with nonzero topological charge. In the confinement phase the magnetic field enhances the local fluctuations of both the electric charge and chiral charge densities. In the deconfinement phase the effects of the magnetic field become smaller, possibly due to thermal screening. Using a simple model of a fireball we obtain a good agreement between our data and experimental results of STAR Collaboration.

  19. Effects on the CMB from magnetic field dissipation before recombination

    Science.gov (United States)

    Kunze, Kerstin E.

    2017-09-01

    Magnetic fields present before decoupling are damped due to radiative viscosity. This energy injection affects the thermal and ionization history of the cosmic plasma. The implications for the CMB anisotropies and polarization are investigated for different parameter choices of a nonhelical stochastic magnetic field. Assuming a Gaussian smoothing scale determined by the magnetic damping wave number at recombination, it is found that magnetic fields with present-day strength less than 0.1 nG and negative magnetic spectral indices have a sizable effect on the CMB temperature anisotropies and polarization.

  20. Transient voltage oscillations in coils

    International Nuclear Information System (INIS)

    Chowdhuri, P.

    1985-01-01

    Magnet coils may be excited into internal voltage oscillations by transient voltages. Such oscillations may electrically stress the magnet's dielectric components to many times its normal stress. This may precipitate a dielectric failure, and the attendant prolonged loss of service and costly repair work. Therefore, it is important to know the natural frequencies of oscillations of a magnet during the design stage, and to determine whether the expected switching transient voltages can excite the magnet into high-voltage internal oscillations. The series capacitance of a winding significantly affects its natural frequencies. However, the series capacitance is difficult to calculate, because it may comprise complex capacitance network, consisting of intra- and inter-coil turn-to-turn capacitances of the coil sections. A method of calculating the series capacitance of a winding is proposed. This method is rigorous but simple to execute. The time-varying transient voltages along the winding are also calculated

  1. Hall effect driven by non-collinear magnetic polarons in diluted magnetic semiconductors

    Science.gov (United States)

    Denisov, K. S.; Averkiev, N. S.

    2018-04-01

    In this letter, we develop the theory of Hall effect driven by non-collinear magnetic textures (topological Hall effect—THE) in diluted magnetic semiconductors (DMSs). We show that a carrier spin-orbit interaction induces a chiral magnetic ordering inside a bound magnetic polaron (BMP). The inner structure of non-collinear BMP is controlled by the type of spin-orbit coupling, allowing us to create skyrmion- (Rashba) or antiskyrmion-like (Dresselhaus) configurations. The asymmetric scattering of itinerant carriers on polarons leads to the Hall response which exists in weak external magnetic fields and at low temperatures. We point out that DMS-based systems allow one to investigate experimentally the dependence of THE both on a carrier spin polarization and on a non-collinear magnetic texture shape.

  2. Competing effects in the magnetic polarization of non-magnetic atoms

    International Nuclear Information System (INIS)

    Boada, R; Piquer, C; Chaboy, J; Laguna-Marco, M A

    2013-01-01

    The magnetic polarization of the Lu 5d states through the Ho 1-x Lu x (Fe 1-y Al y ) 2 series has been studied by means of x-ray magnetic circular dichroism. A combined study of the dichroic signals performed at the Fe K-, Ho L 2 - and Lu L 2,3 -edges gives a complete picture of the polarization scheme at the conduction band. The results show that in the presence of competing localized magnetic moments, μ Fe (3d) and μ Ho (4f), the dichroic signal at the Lu site is mainly due to the Fe atoms, the effect of the magnetic rare-earth being negligible. Estimation of the spin and orbital components of the Lu(5d) induced magnetic moment have been obtained by applying the magneto-optical sum rules derived for x-ray magnetic circular dichroism.

  3. Effect of sample shape on nonlinear magnetization dynamics under an external magnetic field

    International Nuclear Information System (INIS)

    Vagin, Dmitry V.; Polyakov, Oleg P.

    2008-01-01

    Effect of sample shape on the nonlinear collective dynamics of magnetic moments in the presence of oscillating and constant external magnetic fields is studied using the Landau-Lifshitz-Gilbert (LLG) approach. The uniformly magnetized sample is considered to be an ellipsoidal axially symmetric particle described by demagnetization factors and uniaxial crystallographic anisotropy formed some angle with an applied field direction. It is investigated as to how the change in particle shape affects its nonlinear magnetization dynamics. To produce a regular study, all results are presented in the form of bifurcation diagrams for all sufficient dynamics regimes of the considered system. In this paper, we show that the sample's (particle's) shape and its orientation with respect to the external field (system configuration) determine the character of magnetization dynamics: deterministic behavior and appearance of chaotic states. A simple change in the system's configuration or in the shapes of its parts can transfer it from chaotic to periodic or even static regime and back. Moreover, the effect of magnetization precession stall and magnetic moments alignment parallel or antiparallel to the external oscillating field is revealed and the way of control of such 'polarized' states is found. Our results suggest that varying the particle's shape and fields' geometry may provide a useful way of magnetization dynamics control in complex magnetic systems

  4. Effect of Sulfur in Steel on Transient Evolution of Inclusions During Calcium Treatment

    Science.gov (United States)

    Liu, Yang; Zhang, Lifeng; Zhang, Ying; Duan, Haojian; Ren, Ying; Yang, Wen

    2018-04-01

    In the current study, the effect of S content in the molten steel on inclusions during calcium treatment was studied using an induction furnace. The calcium in steel decreased from 48 to 2 ppm, and the sulfur in steel changed a little with time. When sulfur content in steel was as low as 25 ppm during calcium treatment, inclusions shifted from CaO-Al2O3-CaS to Al2O3-CaO with about 35 pct CaO. When the sulfur increased over 90 ppm, more CaS-CaO formed just after the addition of calcium, and then the CaS content decreased from over 45 pct to lower than 15 pct and inclusions were mostly Al2O3-CaO-CaS and Al2O3-CaO with a high Al2O3 content. Thermodynamic calculation predicted the variation of the composition of inclusions, indicating good agreement with the measurement, while a certain deviation existed, especially for heats with 90 and 180 ppm sulfur. A reaction model was proposed for the formation of CaO and CaS, which considered the reaction between calcium vapor bubbles in the zone and the dissolved oxygen and sulfur in the molten steel, as described by a Langmuir-type adsorption isotherm with a reaction occurring on the remaining vacant sites. The variation of transient CaS inclusions was discussed based on the thermodynamic calculation and the morphology evolution of typical inclusions containing CaS.

  5. Effect of transient wave forcing on the behavior of arsenic in a sandy nearshore aquifer

    Science.gov (United States)

    Rakhimbekova, S.; O'Carroll, D. M.; Robinson, C. E.

    2016-12-01

    Waves cause large quantities of coastal water to recirculate across the groundwater-coastal water interface in addition to inducing complex groundwater flows in the nearshore aquifer. Due to the distinct chemical composition of recirculating coastal water compared with discharging terrestrial groundwater, wave-induced recirculations and flows can alter geochemical gradients in the nearshore aquifer which may subsequently affect the mobilization and transport of reactive pollutants (e.g., arsenic). The impact of seasonal geochemical and hydrological variability on the occurrence and mobility of arsenic near the groundwater-surface water interface has been shown previously in riverine settings, however, the impact of high frequency geochemical variations (e.g., varying wave conditions) on arsenic mobility in groundwater-surface water environments is unclear. The objective of the study was to assess the impact of intensified wave conditions on the behavior of arsenic in a nearshore aquifer to determine the factors regulating its mobility and transport to receiving coastal waters. Field investigations were conducted at a permeable beach on the Great Lakes during a period of intensified wave conditions (wave event). High spatial resolution pore water sampling captured the geochemical conditions in the nearshore aquifer prior to the wave event, immediately after the wave event and over a recovery period of 3 weeks following the wave event. Shifts in pH and redox potential (ORP) gradients in response to varying wave conditions caused shifts in the iron and arsenic distributions in the aquifer. Sediment analysis was combined with the pore water distributions to assess the release of sediment-bound arsenic in response to the varying wave conditions. Insight into the effect of transient forcing on arsenic mobility and transport in groundwater-surface water environments is important for evaluating the potential risks associated with this toxic metalloid. The findings of this

  6. Acute effects of exercise posture on executive function in transient ischemic attack patients.

    Science.gov (United States)

    Faulkner, James; Stoner, Lee; Grigg, Rebecca; Fryer, Simon; Stone, Keeron; Lambrick, Danielle

    2017-08-01

    In patients with stroke or transient ischemic attacks (TIA), a decline in executive function may limit an individual's ability to process motor tasks and relearn motor skills. The purpose of this study was to assess the acute effect of exercise posture (seated vs. supine cycle ergometry) on executive function and prefrontal cortex perfusion in patients with TIA. Eleven TIA patients (65 ± 10 years) and 15 age-matched, healthy controls (HC; 62 ± 7 years) completed two exercise tests to maximal capacity (one seated, one supine) and two 30-min submaximal exercise tests (one seated, one supine). Executive function was assessed prior to and following (1.5 min post, 15 min post) the submaximal exercise tests using a Stroop task. Prefrontal cortex perfusion (total hemoglobin) was continuously recorded using near-infrared spectroscopy. There was no Posture (seated, supine) × Group (TIA, HC) interaction for the Stroop task (p > .05). HC completed Stroop tasks significantly faster than TIA (51.9[SD = 10.3] vs. 64.2[8.5] s, respectively), while Stroop completion time significantly improved between baseline and 1.5 min post (61.3[10] vs. 58.1[9.4] s, respectively) and 1.5 min post and 15 min post (54.8[8.9] s). Posture and group had no significant influence on prefrontal cortex perfusion (p > .05). In summary, executive function improves to a similar extent in TIA and age-matched, healthy controls following an acute bout of exercise, regardless of exercise posture. As acute improvements in executive function were maintained for 15 min, there could be an important window of opportunity for assigning executive tasks following exercise rehabilitation for patients with TIA. © 2017 Society for Psychophysiological Research.

  7. Influence of taking into account in-pressurizer convective heat- and mass transfer influence effects at the transients in VVER with code RELAP 5/MOD 3.2

    International Nuclear Information System (INIS)

    Konovalyuk, L.N.; Shevelev, D.V.; Kravchenko, V.G.

    2003-01-01

    PRZ model is proposed which allows taking into account in pressurizer convective heat- and mass transfer influence effects at the transients in VVER (PWR) Type Reactors case when calculations performed with using 1D thermohydraulic codes. The theoretical backgrounds are given to define the transients with the convective coolant instability in PRZ. The instability threshold is given for real PRZ geometry

  8. Simplified Transient Hot-Wire Method for Effective Thermal Conductivity Measurement in Geo Materials: Microstructure and Saturation Effect

    Directory of Open Access Journals (Sweden)

    B. Merckx

    2012-01-01

    Full Text Available The thermal conductivity measurement by a simplified transient hot-wire technique is applied to geomaterials in order to show the relationships which can exist between effective thermal conductivity, texture, and moisture of the materials. After a validation of the used “one hot-wire” technique in water, toluene, and glass-bead assemblages, the investigations were performed (1 in glass-bead assemblages of different diameters in dried, water, and acetone-saturated states in order to observe the role of grain sizes and saturation on the effective thermal conductivity, (2 in a compacted earth brick at different moisture states, and (3 in a lime-hemp concrete during 110 days following its manufacture. The lime-hemp concrete allows the measurements during the setting, desiccation and carbonation steps. The recorded Δ/ln( diagrams allow the calculation of one effective thermal conductivity in the continuous and homogeneous fluids and two effective thermal conductivities in the heterogeneous solids. The first one measured in the short time acquisitions (<1 s mainly depends on the contact between the wire and grains and thus microtexture and hydrated state of the material. The second one, measured for longer time acquisitions, characterizes the mean effective thermal conductivity of the material.

  9. Magnetic field shielding effect for CFETR TF coil-case

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Weiwei; Liu, Xufeng, E-mail: Lxf@ipp.ac.cn; Du, Shuangsong; Zheng, Jinxing

    2017-05-15

    Highlights: • The eddy current of CFETR vacuum vessel can be calculated by using a series of ideal current loops. • The shielding effect with different eddy current is studied by decomposing the exciting magnetic field as two orthogonal components. • The shielding effect can be determined from the rate of eddy current magnetic field to the external magnetic field. - Abstract: The operation of superconducting magnet for fusion device is under the complex magnetic field condition, which affect the stabilization of superconductor. The coil-case of TF coil can shield the magnetic field to some extent. The shielding effect is related to the eddy current of coil-case. The shielding effect with different eddy current is studied by decomposing the exciting magnetic field as two orthogonal components, respectively. The results indicate that the shielding effect of CFETR TF coil-case has obvious different with the different directional magnetic field, and it’s larger for tangential magnetic compared with that for normal field.

  10. Influence of bulk dielectric polarization upon partial discharge transients effect of heterogeneous dielectric geometry

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson; Crichton, George C.

    2000-01-01

    A physically valid theory of partial discharge (PD) transients is based upon the concept of the charge induced upon the detecting electrode by the PD. This induced charge consists of two components. One is associated with the actual space charge in the void, while the other is related to changes...

  11. Effects of thermal stratification on transient free convective flow of a ...

    Indian Academy of Sciences (India)

    2016-09-22

    Sep 22, 2016 ... as well as average skin friction and the rate of heat transfer of nanofluids are discussed and represented graphically. The results are found to be in good agreement with the existing results in literature. Keywords. Nanofluid; thermal stratification; transient; isothermal vertical plate. PACS Nos 44.20.+b; 47; 44.

  12. Transient stability with grid connection and wind turbine drive-train effects

    DEFF Research Database (Denmark)

    Fajardo-R, Luis A.; Medina, Aurelio; Iov, Florin

    2009-01-01

    This paper assesses transient stability of grid-connected wind turbines, combining grid-connection, wind turbine flexibility, and induction generator stability features. Through a grid-connected 2 MW wind turbine cage-generator, the investigation is conducted to identify the critical clearing time...

  13. Effects of 1,25-Dihydroxycholecalciferol on Recovery and Resolution of Late Transient Neonatal Hypocalcemia

    OpenAIRE

    Amaral, Jennifer M.; Abrams, Steve; Karaviti, Lefkothea; McKay, Siripoom V.

    2010-01-01

    Background. Late transient neonatal hypocalcemia with hyperphosphatemia is potentially life-threatening. The use of dihydroxycholecalciferol in the management of neonatal hypocalcemia is unexplored. Objective. We hypothesized adding dihydroxycholecalciferol to intravenous continuous calcium infusion (CaI) will achieve accelerated correction of hypocalcemia. Design/Methods. A controlled double-blind randomized placebo group was organized to compare the addition of dihydroxycholecalciferol ...

  14. The Effect of Sleep Disordered Breathing on the Outcome of Stroke and Transient Ischemic Attack

    DEFF Research Database (Denmark)

    Birkbak, Johannes; Clark, Alice J; Rod, Naja Hulvej

    2014-01-01

    The primary objective was to systematically review the literature on how sleep disordered breathing (SDB) affects recurrence and death among stroke or transient ischemic attack (TIA) patients. A secondary objective was to evaluate how treatment of SDB with continuous positive airway pressure (CPAP...

  15. Differential effects of the transient outward K(+) current activator NS5806 in the canine left ventricle

    DEFF Research Database (Denmark)

    Calloe, Kirstine; Soltysinska, Ewa; Jespersen, Thomas

    2009-01-01

    To examine the electrophysiological and molecular properties of the transient outward current (I(to)) in canine left ventricle using a novel I(to) activator, NS5806, I(to) was measured in isolated epicardial (Epi), midmyocardial (Mid) and endocardial (Endo) cells using whole-cell patch-clamp tech...

  16. Eddy current effect in soft magnetic backlayer for PMR media

    International Nuclear Information System (INIS)

    Tanaka, T.; Yamamoto, S.; Kurisu, H.; Matsuura, M.

    2005-01-01

    Flux density distributions in the recording layer and soft magnetic backlayer of a perpendicular magnetic recording medium were calculated up to 5 GHz using a three-dimensional finite element method electromagnetic field analysis simulator, where eddy current effects in the high-frequency recording process were considered. It is presented that the flux density distribution in a recording layer hardly depends on the eddy current effect, although flux density distribution in a soft magnetic backlayer changes depending on the recording frequency and resistivity of the soft magnetic backlayer

  17. Effect of magnetic fullerene on magnetization reversal created at the Fe/C60 interface.

    Science.gov (United States)

    Mallik, Srijani; Mattauch, Stefan; Dalai, Manas Kumar; Brückel, Thomas; Bedanta, Subhankar

    2018-04-03

    Probing the hybridized magnetic interface between organic semiconductor (OSC) and ferromagnetic (FM) layers has drawn significant attention in recent years because of their potential in spintronic applications. Recent studies demonstrate various aspects of organic spintronics such as magnetoresistance, induced interface moment etc. However, not much work has been performed to investigate the implications of such OSC/FM interfaces on the magnetization reversal and domain structure which are the utmost requirements for any applications. Here, we show that non-magnetic Fullerene can obtain non-negligible magnetic moment at the interface of Fe(15 nm)/C 60 (40 nm) bilayer. This leads to substantial effect on both the magnetic domain structure as well as the magnetization reversal when compared to a single layer of Fe(15 nm). This is corroborated by the polarized neutron reflectivity (PNR) data which indicates presence of hybridization at the interface by the reduction of magnetic moment in Fe. Afterwards, upto 1.9 nm of C 60 near the interface exhibits magnetic moment. From the PNR measurements it was found that the magnetic C 60 layer prefers to be aligned anti-parallel with the Fe layer at the remanant state. The later observation has been confirmed by domain imaging via magneto-optic Kerr microscopy.

  18. Effects of Magnetic Particles Entrance Arrangements on Mixing Efficiency of a Magnetic Bead Micromixer

    Institute of Scientific and Technical Information of China (English)

    Reza Kamali; Seyed Alireza Shekoohi; Alireza Binesh

    2014-01-01

    In this study, a computer code is developed to numerically investigate a magnetic bead micromixer under different conditions. The micromixer consists of a microchannel and numerous micro magnetic particles which enter the micromixer by fluid flows and are actuated by an alternating magnetic field normal to the main flow. An important feature of micromixer which is not considered before by researchers is the particle entrance arrangement into the micromixer. This parameter could effectively affect the micromixer efficiency. There are two general micro magnetic particle entrance arrangements in magnetic bead micromixers: determined position entrance and random position entrance. In the case of determined position entrances, micro magnetic particles enter the micromixer at specific positions of entrance cross section. However, in a random position entrance,particles enter the microchannel with no order. In this study mixing efficiencies of identical magnetic bead micromixers which only differ in particle entrance arrangement are numerically investigated and compared.The results reported in this paper illustrate that the prepared computer code can be one of the most powerful and beneficial tools for the magnetic bead micromixer performance analysis. In addition, the results show that some features of the magnetic bead micromixer are strongly affected by the entrance arrangement of the particles.

  19. A Faraday effect position sensor for interventional magnetic resonance imaging.

    Science.gov (United States)

    Bock, M; Umathum, R; Sikora, J; Brenner, S; Aguor, E N; Semmler, W

    2006-02-21

    An optical sensor is presented which determines the position and one degree of orientation within a magnetic resonance tomograph. The sensor utilizes the Faraday effect to measure the local magnetic field, which is modulated by switching additional linear magnetic fields, the gradients. Existing methods for instrument localization during an interventional MR procedure often use electrically conducting structures at the instruments that can heat up excessively during MRI and are thus a significant danger for the patient. The proposed optical Faraday effect position sensor consists of non-magnetic and electrically non-conducting components only so that heating is avoided and the sensor could be applied safely even within the human body. With a non-magnetic prototype set-up, experiments were performed to demonstrate the possibility of measuring both the localization and the orientation in a magnetic resonance tomograph. In a 30 mT m(-1) gradient field, a localization uncertainty of 1.5 cm could be achieved.

  20. Magnetic memory effects in high temperature superconductors

    International Nuclear Information System (INIS)

    Rockenbauer, A.

    1989-01-01

    Microwave absorption of high temperature oxide superconductors MBa 2 Cu 3 O 7 (M = Y, Er, Dy, Ho, Lu, Tm, Gd) at 77 K have been studied by ESR. In granular samples diamagnetic zero-field resonance and strong ESR baseline hysteresis have been observed: for increasing field sweep - a high, for decreasing one - a low, while in constant field the baseline approaches the middle position with kinetics typical of spin-glasses. The hysteresis amplitude, i.e. the deviation of high and low baselines, possesses maximum at zero field if the sample is cooled down in zero field. In case of field cooling both the diamagnetic resonance and hysteresis maximum are shifted as a function of relative direction of the fields where the samples are cooled and measured, respectively. The shift is caused by the remanent diamagnetism of trapped fluxons. The hysteresis critically depends on the modulation amplitude of magnetic field, and no hysteresis can be observed if the microwave absorption is detected without field modulation. By applying saw-tooth sweep the spin-glass can be driven between two extreme hysteresis states, and the ESR response is rectangular for large saw-tooth amplitude and linear - for small one, while for intermediate amplitudes the recording shows characteristic memory effects. The hysteresis memory is explained in terms of loop distribution of fluxons. In the single crystal the fluxon absorptions are also detected and the separation of fluxon lines can be related to the hysteresis in granular samples. (author)

  1. Effect of magnetic polarity on surface roughness during magnetic field assisted EDM of tool steel

    Science.gov (United States)

    Efendee, A. M.; Saifuldin, M.; Gebremariam, MA; Azhari, A.

    2018-04-01

    Electrical discharge machining (EDM) is one of the non-traditional machining techniques where the process offers wide range of parameters manipulation and machining applications. However, surface roughness, material removal rate, electrode wear and operation costs were among the topmost issue within this technique. Alteration of magnetic device around machining area offers exciting output to be investigated and the effects of magnetic polarity on EDM remain unacquainted. The aim of this research is to investigate the effect of magnetic polarity on surface roughness during magnetic field assisted electrical discharge machining (MFAEDM) on tool steel material (AISI 420 mod.) using graphite electrode. A Magnet with a force of 18 Tesla was applied to the EDM process at selected parameters. The sparks under magnetic field assisted EDM produced better surface finish than the normal conventional EDM process. At the presence of high magnetic field, the spark produced was squeezed and discharge craters generated on the machined surface was tiny and shallow. Correct magnetic polarity combination of MFAEDM process is highly useful to attain a high efficiency machining and improved quality of surface finish to meet the demand of modern industrial applications.

  2. Hyperfine magnetic fields for 5d impurities in iron: pre-equilibrium effects, texture and the Aharoni effect

    International Nuclear Information System (INIS)

    Stuchbery, A.E.; Bezakova, E.

    1998-01-01

    Static magnetic hyperfine fields acting on impurities recoil-implanted into ferromagnetic hosts following heavy-ion induced reactions have been studied using the implantation perturbed angular correlation (IMPAC) technique to determine the magnetic moments of subnanosecond excited states in neutron-deficient nuclei. Problems, which in time-integral measurements cannot always be treated independently were studied and include: (i) corrections for the transient field effect, (ii) whether the hyperfine field is parallel to the applied field, (iii) whether the implanted nuclei all experience the same magnetic interaction, (iv) the time the static field takes to reach equilibrium after implantation. The focus here is on pre-equilibrium phenomena associated with the implantation process and the direction of the internal magnetic field at implanted impurities after equilibrium is reached. It was found that the internal field does become increasingly misaligned with respect to external field direction at fields below 0.08 T. This is due to the incomplete saturation of the foil and not to the microscopic effect as proposed by Aharoni

  3. Kinetic modeling of Nernst effect in magnetized hohlraums

    OpenAIRE

    Joglekar, A. S.; Ridgers, Christopher Paul; Kingham, R J; Thomas, A. G. R.

    2016-01-01

    We present nanosecond time-scale Vlasov-Fokker-Planck-Maxwell modeling of magnetized plasma transport and dynamics in a hohlraum with an applied external magnetic field, under conditions similar to recent experiments. Self-consistent modeling of the kinetic electron momentum equation allows for a complete treatment of the heat flow equation and Ohm's law, including Nernst advection of magnetic fields. In addition to showing the prevalence of nonlocal behavior, we demonstrate that effects such...

  4. Magnetic shape memory effect and highly mobile twin boundaries

    Czech Academy of Sciences Publication Activity Database

    Heczko, Oleg

    2014-01-01

    Roč. 30, č. 13 (2014), s. 1559-1578 ISSN 0267-0836 R&D Projects: GA ČR(CZ) GAP107/11/0391 Institutional support: RVO:68378271 Keywords : magnetic shape memory effect * ferromagnetic martensite * twinning * magnetically induced reorientation * reviews Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.995, year: 2014 http://dx.doi.org/10.1179/1743284714Y.0000000599

  5. The effects of magnetic fields on carnauba wax electret formation

    Science.gov (United States)

    Clator, Irvin G.

    1987-08-01

    The results of thermally stimulated depolarization current and effective surface charge-density measurements indicate that magnetic fields do not produce carnauba wax electrets and that previously reported data can be attributed to nonmagnetic effects.

  6. The Effect of Metal-Semiconductor Contact on the Transient Photovoltaic Characteristic of HgCdTe PV Detector

    Directory of Open Access Journals (Sweden)

    Haoyang Cui

    2013-01-01

    Full Text Available The transient photovoltaic (PV characteristic of HgCdTe PV array is studied using an ultrafast laser. The photoresponse shows an apparent negative valley first, then it evolves into a positive peak. By employing a combined theoretical model of pn junction and Schottky potential, this photo-response polarity changing curves can be interpreted well. An obvious decreasing of ratio of negative valley to positive peak can be realized by limiting the illumination area of the array electrode. This shows that the photoelectric effect of Schottky barrier at metal-semiconductor (M/S interface is suppressed, which will verify the correctness of the model. The characteristic parameters of transient photo-response induced from p-n junction and Schottky potential are extracted by fitting the response curve utilizing this model. It shows that the negative PV response induced by the Schottky barrier decreases the positive photovoltage generated by the pn junction.

  7. The effect of boron dilution transient on the VVER-1000 reactor core using MCNP and COBRA-EN codes

    Energy Technology Data Exchange (ETDEWEB)

    Jafari, Naser; Talebi, Saeed [Amirkabir Univ. of Technology, Tehran Polytechnic (Iran, Islamic Republic of). Dept. of Energy Engineering and Physics

    2017-07-15

    In this paper, the effect of boron dilution transient, as a consequence of the malfunction of the boron control system, was investigated in a VVER-1000 reactor, and then an appropriate setpoint was determined for the actuation of the emergency protection system to the reactor shutdown. In order to simulate the boron dilution, first, the whole reactor core was simulated by MCNPX code to compute the radial and axial power distribution. Then, the COBRA-EN code was employed using calculated power distribution for analyzing the thermal-hydraulic of hot fuel assembly and for extracting the safety parameters. For the safe operation of the reactor, certain parameters must be in defined specified ranges. Comparison between our results and FSARs data shows that the present modeling provides a good prediction of boron dilution transient with the maximum relative difference about 4%.

  8. Effect of transient liquid flow on retention characteristics of screen acquisition systems. [design of Space Shuttle feed system

    Science.gov (United States)

    Cady, E. C.

    1977-01-01

    A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

  9. The effect of the virtual mass force term on the stability of transient two-phase flow analysis

    International Nuclear Information System (INIS)

    Watanabe, Tadashi; Hirano, Masashi; Tanabe, Fumiya

    1989-08-01

    The effect of the virtual mass force term on the stability of transient two-phase flow analysis is studied. The objective form of the virtual mass acceleration is used. The virtual mass coefficient is determined from the stability condition of basic equations against infinitesimal high wave-number perturbations. The parameter is chosen so that a reasonable agreement between the analytical and experimental sound speed in two-phase flows can be obtained. A one-dimensional sedimentation problem is simulated by the MINCS code which is a tool for transient two-phase flow analysis. The stability analysis is performed for the numerical procedure. It is shown that calculated results are stabilized so long as the virtual mass coefficient satisfies the stability condition of differential equations. (author)

  10. Effects of magnetic fields on main sequence stars

    International Nuclear Information System (INIS)

    Hubbard, E.N.

    1981-01-01

    A number of effects of low to medium strength ( 2 /8π) magnetic field pressure term so that the only effect of such a field may come from its inhibiting convection in the core. Isochrones of both convective and radiative core models of 2-5 M are presented. In the deep envelope, mixing of partially nuclear processed material driven by rising and falling magnetic flux tubes may be seen. The effects of this mixing will be brought to the surface during the deep convection phase of the star's tenure as a red giant. This model is used to predict a signature for magnetic mixing based on the CNO isotope and abundance ratios. In the outer envelope the gas pressure is low enough that one might expect to see a perturbation of the stellar structure due to the magnetic field pressure itself. This perturbation is calculated under several physical models for intermediate and high mass stars and it is determined that sufficient magnetic field energy may be available in the outer envelope to expand a star by about 20% over its unperturbed radius. Finally the evidence for the existence of non-magnetic neutron stars is considered, concluding that while no non-magnetic neutron stars have ever been positively identified, there is no evidence that prevents the existence of at least as many non-magnetic as magnetic neutron stars

  11. Transient effects of tendon disconnection on the survivability of a TLP in moderate-strength hurricane conditions

    Directory of Open Access Journals (Sweden)

    Moo Hyun Kim

    2009-09-01

    Full Text Available The primary objective of this paper is to investigate the dynamic stability and survivability of a four-column classic TLP (tension-leg platform under less-than-extreme storm conditions where one or more tendons have been lost due to damage or disconnect. The transient responses of the platform and tendon tensions at the moment of disconnection are particularly underscored. The numerical simulation is based on the BE-FE hybrid hull-tendon-riser coupled dynamic analysis in time domain. Compared to the common industry practice of checking the system without a failed tendon in the beginning, the maximum tension on the neighboring tendon can be significantly increased at the moment of disconnection due to the snap-like transient effects, which can lead to unexpected failure of the total system. It is also found that the transient effects can be reduced with the presence of TTRs (top-tensioned risers with pneumatic tensioners. It is also seen that the TLP cannot survive in the 100-yr hurricane condition after losing one tendon.

  12. Age-Specific Associations of Renal Impairment With Magnetic Resonance Imaging Markers of Cerebral Small Vessel Disease in Transient Ischemic Attack and Stroke.

    Science.gov (United States)

    Liu, Bian; Lau, Kui Kai; Li, Linxin; Lovelock, Caroline; Liu, Ming; Kuker, Wilhelm; Rothwell, Peter M

    2018-04-01

    It has been hypothesized that cerebral small vessel disease (SVD) and chronic renal impairment may be part of a multisystem small-vessel disorder, but their association may simply be as a result of shared risk factors (eg, hypertension) rather than to a systemic susceptibility to premature SVD. However, most previous studies were hospital based, most had inadequate adjustment for hypertension, many were confined to patients with lacunar stroke, and none stratified by age. In a population-based study of transient ischemic attack and ischemic stroke (OXVASC [Oxford Vascular Study]), we evaluated the magnetic resonance imaging markers of cerebral SVD, including lacunes, white matter hyperintensities, cerebral microbleeds, and enlarged perivascular space. We studied the age-specific associations of renal impairment (estimated glomerular filtration rate <60 mL/min per 1.73 m 2 ) and total SVD burden (total SVD score) adjusting for age, sex, vascular risk factors, and premorbid blood pressure (mean blood pressure during 15 years preevent). Of 1080 consecutive patients, 1028 (95.2%) had complete magnetic resonance imaging protocol and creatinine measured at baseline. Renal impairment was associated with total SVD score (odds ratio [OR], 2.16; 95% confidence interval [CI], 1.69-2.75; P <0.001), but only at age <60 years (<60 years: OR, 3.97; 95% CI, 1.69-9.32; P =0.002; 60-79 years: OR, 1.01; 95% CI, 0.72-1.41; P =0.963; ≥80 years: OR, 0.95; 95% CI, 0.59-1.54; P =0.832). The overall association of renal impairment and total SVD score was also attenuated after adjustment for age, sex, history of hypertension, diabetes mellitus, and premorbid average systolic blood pressure (adjusted OR, 0.76; 95% CI, 0.56-1.02; P =0.067), but the independent association of renal impairment and total SVD score at age <60 years was maintained (adjusted OR, 3.11; 95% CI, 1.21-7.98; P =0.018). Associations of renal impairment and SVD were consistent for each SVD marker at age <60 years but

  13. The effect of retarding torque during a flow transient for Tehran Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Farhadi, Kazem, E-mail: kfarhadi@aeoi.org.ir [Engineering Science Research Group, Nuclear Science Research School, Nuclear Science and Technology Research Institute, AEOI, P.O. Box 11365-3486, Tehran (Iran, Islamic Republic of)

    2011-02-15

    The primary cooling system of the Tehran Research Reactor (TRR) has been analysed for a possible flow transient phenomenon caused by power cut-off. All the components of the TRR primary cooling loop that offer resistance to the coolant flow are physically modelled. Differential equations of motion for the coolant in the primary piping of the TRR and for the rotating parts of the centrifugal pump are then derived. The equation of flow motion is solved simultaneously with momentum conservation equation of the rotating parts of the pump which predicts the TRR pump speed during the flow transient. Electrical and mechanical losses are measured for the TRR three-phase induction motor in order to calculate the motor retarding torque during the event. The results of the present study are compared with the other similar primary loop results. The present model shows good agreement with the existing experimental and theoretical studies.

  14. The effect of a transient thermal lens on the Nd:YVO4 laser output

    International Nuclear Information System (INIS)

    Yi, Jonghoon; Lee, Kangin; Kim, Youngjung; Kwon, Jinhyuk

    2010-01-01

    A Nd:YVO 4 laser was pumped by using a diode laser, which has maximum cw pump power of 1 W. The driving current of the diode laser was modulated to have a square waveform. The Nd:YVO 4 laser output power increased linearly and then saturated when the quasi-cw diode laser pulse was focused on the crystal. When the same diode laser pulse was applied on the crystal, transient thermal lensing in the Nd:YVO 4 crystal was monitored by using a probe beam in a non-lasing condition. The TEM 00 mode diameter of the laser was calculated as a function of the focal length of the thermal lens. The results indicated that transient thermal lensing in the crystal was the main cause of the temporally varying output.

  15. Effects of different block size distributions in pressure transient response of naturally fractured reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Montazeri, G.H. [Islamic Azad University, Mahshahr (Iran, Islamic Republic of). Dept. of Chemical and Petroleum Engineering], E-mail: montazeri_gh@yahoo.com; Tahami, S.A. [Mad Daneshgostar Tabnak Co. (MDT),Tehran (Iran, Islamic Republic of); Moradi, B.; Safari, E. [Iranian Central Oil Fields Co, Tehran (Iran, Islamic Republic of)], E-mail: morady.babak@gmail.com

    2011-07-15

    This paper presents a model for pressure transient and derivative analysis for naturally fractured reservoirs by a formulation of inter porosity flow incorporating variations in matrix block size, which is inversely related to fracture intensity. Geologically realistic Probability Density Functions (PDFs) of matrix block size, such as uniform, bimodal, linear and exponential distributions, are examined and pseudo-steady-state and transient models for inter porosity flow are assumed. The results have been physically interpreted, and, despite results obtained by other authors, it was found that the shape of pressure derivative curves for different PDFs are basically identical within some ranges of block size variability, inter porosity skin, PDFs parameters and matrix storage capacity. This tool can give an insight on the distribution of block sizes and shapes, together with other sources of information such as Logs and geological observations. (author)

  16. PTAC: a computer program for pressure-transient analysis, including the effects of cavitation. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Kot, C A; Youngdahl, C K

    1978-09-01

    PTAC was developed to predict pressure transients in nuclear-power-plant piping systems in which the possibility of cavitation must be considered. The program performs linear or nonlinear fluid-hammer calculations, using a fixed-grid method-of-characteristics solution procedure. In addition to pipe friction and elasticity, the program can treat a variety of flow components, pipe junctions, and boundary conditions, including arbitrary pressure sources and a sodium/water reaction. Essential features of transient cavitation are modeled by a modified column-separation technique. Comparisons of calculated results with available experimental data, for a simple piping arrangement, show good agreement and provide validation of the computational cavitation model. Calculations for a variety of piping networks, containing either liquid sodium or water, demonstrate the versatility of PTAC and clearly show that neglecting cavitation leads to erroneous predictions of pressure-time histories.

  17. Effect of pressure on the transient swelling rate of oxide fuel

    International Nuclear Information System (INIS)

    Gruber, E.E.

    1982-04-01

    An analysis of the transient swelling rate of oxide fuel, based on fission-gas bubble conditions calculated with the FRAS3 code, has been developed and implemented in the code. The need for this capability arises in the coupling of the FRAS3 fission-gas analysis code to the FPIN fuel-pin mechanics code. An efficient means of closely coupling the calculations of swelling strains and stresses between the modules is required. The present analysis provides parameters that allow the FPIN calculation to proceed through a fairly large time step, using estimated swelling rates, to calculate the stresses. These stress values can then be applied in the FRAS3 detailed calculation to refine the swelling calculation, and to provide new values for the parameters to estimate the swelling in the next time step. The swelling rates were calculated for two representative transients and used to estimate swelling over a short time period for various stress levels

  18. Annealing effects on magnetic properties of silicone-coated iron-based soft magnetic composites

    Science.gov (United States)

    Wu, Shen; Sun, Aizhi; Zhai, Fuqiang; Wang, Jin; Zhang, Qian; Xu, Wenhuan; Logan, Philip; Volinsky, Alex A.

    2012-03-01

    This paper focuses on novel iron-based soft magnetic composites synthesis utilizing high thermal stability silicone resin to coat iron powder. The effect of an annealing treatment on the magnetic properties of synthesized magnets was investigated. The coated silicone insulating layer was characterized by scanning electron microscopy and energy dispersive X-ray spectroscopy. Silicone uniformly coated the powder surface, resulting in a reduction of the imaginary part of the permeability, thereby increasing the electrical resistivity and the operating frequency of the synthesized magnets. The annealing treatment increased the initial permeability, the maximum permeability, and the magnetic induction, and decreased the coercivity. Annealing at 580 °C increased the maximum permeability by 72.5%. The result of annealing at 580 °C shows that the ferromagnetic resonance frequency increased from 2 kHz for conventional epoxy resin coated samples to 80 kHz for the silicone resin insulated composites.

  19. Point kinetics improvements to evaluate three-dimensional effects in transients calculation

    International Nuclear Information System (INIS)

    Castellotti, U.

    1987-01-01

    A calculation method, which considers the flux axial perturbations in the parameters related to the reactivity within a point kinetics model, is described. The method considered uses axial factors of consideration which act on the thermohydraulic variables included in the reactivity calculation. The PUMA three-dimensional code as reference model for the comparisons, is used. The limitations inherent to the reactivity balance of the point models used in the transients calculation, are given. (Author)

  20. Computational Analysis of Effect of Transient Fluid Force on Composite Structures

    Science.gov (United States)

    2013-12-01

    as they well represent an E-glass fiber reinforced composite frequently used in research and industrial applications. The fluid domain was sized...provide unique perspectives on peak stress ratios . The two models both share increased structural rigidity. The cylinder is reinforced by... Poisson ratio of 0.3 and Young’s modulus of 20 GPa were added to the transient structural engineering data cell (Figure 69). 78 Figure 69. E-Glass

  1. Ionizing Shocks in Argon. Part 2: Transient and Multi-Dimensional Effects (Preprint)

    Science.gov (United States)

    2010-09-09

    stability in ionizing monatomic gases. Part 1. Argon ,” J. Fluid Mech., 84, 55 (1978). 2M. P. F. Bristow and I. I. Glass, “ Polarizability of singly...Article 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Ionizing Shocks in Argon . Part 2: Transient...Physics. 14. ABSTRACT We extend the computations of ionizing shocks in argon to unsteady and multi-dimensional, using a collisional-radiative

  2. DC magnetic field sensing based on the nonlinear magnetoelectric effect in magnetic heterostructures

    International Nuclear Information System (INIS)

    Burdin, Dmitrii; Chashin, Dmitrii; Ekonomov, Nikolai; Fetisov, Leonid; Fetisov, Yuri; Shamonin, Mikhail

    2016-01-01

    Recently, highly sensitive magnetic field sensors using the magnetoelectric effect in composite ferromagnetic-piezoelectric layered structures have been demonstrated. However, most of the proposed concepts are not useful for measuring dc magnetic fields, because the conductivity of piezoelectric layers results in a strong decline of the sensor’s sensitivity at low frequencies. In this paper, a novel functional principle of magnetoelectric sensors for dc magnetic field measurements is described. The sensor employs the nonlinear effect of voltage harmonic generation in a composite magnetoelectric structure under the simultaneous influence of a strong imposed ac magnetic field and a weak dc magnetic field to be measured. This physical effect arises due to the nonlinear dependence of the magnetostriction in the ferromagnetic layer on the magnetic field. A sensor prototype comprising of a piezoelectric fibre transducer sandwiched between two layers of the amorphous ferromagnetic Metglas ® alloy was fabricated. The specifications regarding the magnetic field range, frequency characteristics, and noise level were studied experimentally. The prototype showed the responsivity of 2.5 V mT −1 and permitted the measurement of dc magnetic fields in the range of ∼10 nT to about 0.4 mT. Although sensor operation is based on the nonlinear effect, the sensor response can be made linear with respect to the measured magnetic field in a broad dynamic range extending over 5 orders of magnitude. The underlying physics is explained through a simplified theory for the proposed sensor. The functionality, differences and advantages of the magnetoelectric sensor compare well with fluxgate magnetometers. The ways to enhance the sensor performance are considered. (paper)

  3. Study on transient hydrogen behavior and effect on passive containment cooling system of the advanced PWR

    International Nuclear Information System (INIS)

    Wang Yan

    2014-01-01

    A certain amount of hydrogen will be generated due to zirconium-steam reaction or molten corium concrete interaction during severe accidents in the pressurized water reactor (PWR). The generated hydrogen releases into the containment, and the formed flammable mixture might cause deflagration or detonation to produce high thermal and pressure loads on the containment, which may threaten the integrity of the containment. The non-condensable hydrogen in containment may also reduce the steam condensation on the containment surface to affect the performance of the passive containment cooling system (PCCS). To study the transient hydrogen behavior in containment with the PCCS performance during the accidents is significant for the further study on the PCCS design and the hydrogen risk mitigation. In this paper, a new developed PCCS analysis code with self-reliance intellectual property rights, which had been validated by comparison on the transients in the containment during the design basis accidents with other developed PCCS analysis code, is brief introduced and used for the transient simulation in the containment under a postulated small break LOCA of cold-leg. The results show that the hydrogen will flow upwards with the coolant released from the break and spread in the containment by convection and diffusion, and it results in the increase of the pressure in the containment due to reducing the heat removal capacity of the PCCS. (author)

  4. Effective image differencing with convolutional neural networks for real-time transient hunting

    Science.gov (United States)

    Sedaghat, Nima; Mahabal, Ashish

    2018-06-01

    Large sky surveys are increasingly relying on image subtraction pipelines for real-time (and archival) transient detection. In this process one has to contend with varying point-spread function (PSF) and small brightness variations in many sources, as well as artefacts resulting from saturated stars and, in general, matching errors. Very often the differencing is done with a reference image that is deeper than individual images and the attendant difference in noise characteristics can also lead to artefacts. We present here a deep-learning approach to transient detection that encapsulates all the steps of a traditional image-subtraction pipeline - image registration, background subtraction, noise removal, PSF matching and subtraction - in a single real-time convolutional network. Once trained, the method works lightening-fast and, given that it performs multiple steps in one go, the time saved and false positives eliminated for multi-CCD surveys like Zwicky Transient Facility and Large Synoptic Survey Telescope will be immense, as millions of subtractions will be needed per night.

  5. Investigation of effective factors of transient thermal stress of the MONJU-System components

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Masaaki; Hirayama, Hiroshi; Kimura, Kimitaka; Jinbo, M. [Toshiba Corp., Kawasaki, Kanagawa (Japan)

    1999-03-01

    Transient thermal stress of each system Component in the fast breeder reactor is an uncertain factor on it's structural design. The temperature distribution in a system component changes over a wide range in time and in space. An unified evaluation technique of thermal, hydraulic, and structural analysis, in which includes thermal striping, temperature stratification, transient thermal stress and the integrity of the system components, is required for the optimum design of tho fast reactor plant. Thermal boundary conditions should be set up by both the transient thermal stress analysis and the structural integrity evaluation of each system component. The reasonable thermal boundary conditions for the design of the MONJU and a demonstration fast reactor, are investigated. The temperature distribution analysis models and the thermal boundary conditions on the Y-piece structural parts of each system component, such as reactor vessel, intermediate heat exchanger, primary main circulation pump, steam generator, superheater and upper structure of reactor core, are illustrated in the report. (M. Suetake)

  6. Effects of magnetic fields on the quark–gluon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Bali, G.S. [Institute for Theoretical Physics, Universität Regensburg, D-93040 Regensburg (Germany); Tata Institute of Fundamental Research, Homi Bhabha Road, Mumbai 400005 (India); Bruckmann, F. [Institute for Theoretical Physics, Universität Regensburg, D-93040 Regensburg (Germany); Endrődi, G., E-mail: gergely.endrodi@physik.uni-r.de [Institute for Theoretical Physics, Universität Regensburg, D-93040 Regensburg (Germany); Fodor, Z. [Eötvös University, Theoretical Physics, Pázmány P. s 1/A, H-1117, Budapest (Hungary); Bergische Universität Wuppertal, Theoretical Physics, 42119 Wuppertal (Germany); Jülich Supercomputing Centre, Forschungszentrum Jülich, D-52425 Jülich (Germany); Katz, S.D. [Eötvös University, Theoretical Physics, Pázmány P. s 1/A, H-1117, Budapest (Hungary); MTA-ELTE Lendület Lattice Gauge Theory Research Group (Hungary); Schäfer, A. [Institute for Theoretical Physics, Universität Regensburg, D-93040 Regensburg (Germany)

    2014-11-15

    In this talk, the response of the thermal QCD medium to external (electro)magnetic fields is studied using continuum extrapolated lattice results at physical quark masses. The magnetic susceptibility of QCD is calculated, revealing a strong paramagnetic response at high temperatures. This paramagnetism is shown to result in an anisotropic squeezing of the quark–gluon plasma in non-central heavy-ion collisions, implying a sizeable contribution to the elliptic flow. Another aspect is the magnetic response of topologically non-trivial domains to the magnetic field. We quantify this effect on the lattice and compare the results to a simple model estimate.

  7. Effects of the magnetic field on the structure of materials

    International Nuclear Information System (INIS)

    Nakajima, Tetsuo

    1984-02-01

    This is a report of the ''Meeting on the effects of a magnetic field on the structure of materials'' held at KEK, Japan. The purpose of the Meeting was to study the diffraction of SR X-ray in a magnetic field. It was found that the effects of a magnetic field have been seen in various substnaces. The effects are due to the Zeeman effect, the Lamor diamagnetism, the Landau diamagnetism, the Meissner effect and the polarization effect. The topics discussed at the Meeting were the structure study of biological specimens by field orientation, the study of cell structure by field orientation, the phase transition under a strong pulse field, the behavior of high molecular liquid crystal in a magnetic field, the change of the f-electron density of the Tb 3+ ions in Tb IG in a magnetic field at low temperature, an electromagnet loaded on a goniometer and an in-situ observation system for the structure of magnetic domain, the control of structural phase transition by a magnetic field, the use of synchrotron orbit radiation for the structural analysis of random systems, and the field effect on chemical reactions. (Kato, T.)

  8. Electrical detection of magnetization dynamics via spin rectification effects

    Energy Technology Data Exchange (ETDEWEB)

    Harder, Michael, E-mail: michael.harder@umanitoba.ca; Gui, Yongsheng, E-mail: ysgui@physics.umanitoba.ca; Hu, Can-Ming, E-mail: hu@physics.umanitoba.ca

    2016-11-23

    The purpose of this article is to review the current status of a frontier in dynamic spintronics and contemporary magnetism, in which much progress has been made in the past decade, based on the creation of a variety of micro and nanostructured devices that enable electrical detection of magnetization dynamics. The primary focus is on the physics of spin rectification effects, which are well suited for studying magnetization dynamics and spin transport in a variety of magnetic materials and spintronic devices. Intended to be intelligible to a broad audience, the paper begins with a pedagogical introduction, comparing the methods of electrical detection of charge and spin dynamics in semiconductors and magnetic materials respectively. After that it provides a comprehensive account of the theoretical study of both the angular dependence and line shape of electrically detected ferromagnetic resonance (FMR), which is summarized in a handbook format easy to be used for analysing experimental data. We then review and examine the similarity and differences of various spin rectification effects found in ferromagnetic films, magnetic bilayers and magnetic tunnel junctions, including a discussion of how to properly distinguish spin rectification from the spin pumping/inverse spin Hall effect generated voltage. After this we review the broad applications of rectification effects for studying spin waves, nonlinear dynamics, domain wall dynamics, spin current, and microwave imaging. We also discuss spin rectification in ferromagnetic semiconductors. The paper concludes with both historical and future perspectives, by summarizing and comparing three generations of FMR spectroscopy which have been developed for studying magnetization dynamics.

  9. Magnetic field sensor based on asymmetric inverse Wiedemann effect

    Czech Academy of Sciences Publication Activity Database

    Kraus, Luděk; Malátek, M.; Dvořák, M.

    2008-01-01

    Roč. 142, č. 2 (2008), s. 468-473 ISSN 0924-4247 Institutional research plan: CEZ:AV0Z10100520 Keywords : magnetic field sensor * inverse Wiedemann effect * off-diagonal magnetoimpedance * amorphous ribbon Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.724, year: 2008

  10. Magnetic microbead detection using the planar Hall effect

    International Nuclear Information System (INIS)

    Ejsing, Louise; Hansen, Mikkel F.; Menon, Aric K.; Ferreira, Hugo A.; Graham, Daniel L.; Freitas, Paulo P.

    2005-01-01

    Magnetic sensors based on the planar Hall effect of exchanged-biased permalloy have been fabricated and characterized. It is demonstrated that the sensors are feasible for detecting just a few commercial 2.0 μm magnetic beads commonly used for bioseparation (Micromer-M, Micromod, Germany) and that the sensor sense current is sufficient to generate a signal from the beads

  11. Planar Hall effect sensor for magnetic micro- and nanobead detection

    DEFF Research Database (Denmark)

    Ejsing, Louise Wellendorph; Hansen, Mikkel Fougt; Menon, Aric Kumaran

    2004-01-01

    Magnetic bead sensors based on the planar Hall effect in thin films of exchange-biased permalloy have been fabricated and characterized. Typical sensitivities are 3 muV/Oe mA. The sensor response to an applied magnetic field has been measured without and with coatings of commercially available 2 ...

  12. Evaluation of anti-fibrosis effect of compound Biejia Ruangan tablets with transient elastography

    Directory of Open Access Journals (Sweden)

    ZHANG Ning

    2013-10-01

    Full Text Available ObjectiveTo evaluate the clinical efficacy of compound Biejia Ruangan tablets using transient elastography in patients with hepatitis B-induced compensated liver cirrhosis who are concurrently treated with entecavir. MethodsIn this prospective, randomized, and controlled study, 100 patients with hepatitis B-induced compensated liver cirrhosis were randomly assigned to the control group and the experimental group in a ratio of 1:1. The patients in the control group were treated with the anti-virus drug entecavir alone, whereas the patients in the experimental group were treated with entecavir and compound Biejia Ruangan tablets for anti-fibrosis therapy. The patients were followed up at 6 and 12 months. After treatment, the changes in transient elasticity values were evaluated, and the transient elasticity values were compared between the two groups. Continuous variables were compared with the t test and categorical data as well as rates were compared with the chi-square test. ResultsTreatment with compound Biejia Ruangan tablets led to significantly lower transient elasticity values in the experimental group than in the control group at 6 and 12 months (t = 2.963, P = 0.004; t = 2.239, P = 0.027. Transient elasticity values at 6 and 12 months were significantly lower than their respective baseline levels in the control group (t = 4.295, P <0.001 for comparison between values at baseline and 6 months; t = 6.109, P <0.001 for comparison between values at baseline and 12 months; t = 5.394, P <0.001 for comparison between values at 6 and 12 months and the experimental group (t = 8.505, P <0.001 for comparison between values at baseline and 6 months; t = 9.882, P <0.001 for comparison between values at baseline and 12 months; t = 7.930, P <0.001 for comparison between values at 6 months and 12 months. At 12 months, the proportion of patients with liver cirrhosis in the experimental group was significantly lower than that in the control

  13. Health-related biological effects of electric, magnetic, and electro-magnetic fields with special reference to nonthermal effects

    International Nuclear Information System (INIS)

    Stevenson, A.F.G.

    1993-02-01

    This expert report is a supplement to the report by L. von Klitzing (The actions and effects of electric, magnetic, and electro-magnetic fields in man with special reference to athermal effects) and concerns in particular the biological effects on cationic homeostasis and cell regulation with special reference to calcium and the effects on the pineal gland. The report concludes with statements on teratogenicity, concerogenicity, mutagenicity and a bibliography of literature. (VHE) [de

  14. The effect of external magnetic field changing on the correlated quantum dot dynamics

    Science.gov (United States)

    Mantsevich, V. N.; Maslova, N. S.; Arseyev, P. I.

    2018-06-01

    The non-stationary response of local magnetic moment to abrupt switching "on" and "off" of external magnetic field was studied for a single-level quantum dot (QD) coupled to a reservoir. We found that transient processes look different for the shallow and deep localized energy level. It was demonstrated that for deep energy level the relaxation rates of the local magnetic moment strongly differ in the case of magnetic field switching "on" or "off". Obtained results can be applied in the area of dynamic memory devices stabilization in the presence of magnetic field.

  15. Effect of recording condition on the diffraction efficiency of magnetic hologram with magnetic garnet films

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Yuichi, E-mail: nakamura@ee.tut.ac.jp; Takagi, Hiroyuki; Lim, Pang Boey; Inoue, Mitsuteru [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, 1-1 Tempaku-cho, Toyohashi, Aichi 441-8580 (Japan)

    2014-09-14

    A holographic memory has been attracting attention as recording media with high recording density and high data transfer rate. We have studied the magnetic garnets as a rewritable and long life media for magnetic holography. However, since the signal intensity of reconstructed image was relatively low, the effects of recording conditions on the diffraction efficiency of magnetic hologram were investigated with experiments and the numerical simulation using COMSOL multi-physics. The diffraction efficiency tends to decrease as increasing the spatial frequency, and the use of short pulse laser with the pulse width of 50 ps was found to be effective to achieve high diffraction efficiency. This suggests that the formation of clear magnetic fringe similar to interference pattern can be obtained by the use of short pulse laser since undesirable heat diffusion during radiation does not occur. On the other hand, the diffraction efficiency increased as increasing the film thickness up to 3.1 μm but was saturated in the garnet film thicker than 3.1 μm in the case of spatial frequency of 1500 line pair/mm. The numerical simulation showed that the effective depth of magnetic fringe was limited about 1.8 μm irrespective of the garnet film thickness because the fringes were connected by thermal diffusion near the surface of the film, and the effective depth is limited due to this connection of the magnetic fringe. Avoiding this fringe connection, much higher diffraction efficiency will be achieved.

  16. Effects of magnetic fields in white dwarfs

    International Nuclear Information System (INIS)

    Franzon, Bruno; Schramm, Stefan

    2017-01-01

    We perform calculations of white dwarfs endowed with strong magnetic fields. White dwarfs are the progenitors of supernova Type Ia explosions and they are widely used as candles to show that the Universe is expanding and accelerating. However, observations of ultraluminous supernovae have suggested that the progenitor of such an explosion should be a white dwarf with mass above the well-known Chandrasekhar limit ∼ 1.4 M⊙. In corroboration with other works, but by using a fully general relativistic framework, we obtained also strongly magnetized white dwarfs with masses M ∼ 2.0 M⊙. (paper)

  17. Magnetic pressure effects in a plasma-liner interface

    Science.gov (United States)

    García-Rubio, F.; Sanz, J.

    2018-04-01

    A theoretical analysis of magnetic pressure effects in a magnetized liner inertial fusion-like plasma is presented. In previous publications [F. García-Rubio and J. Sanz, Phys. Plasmas 24, 072710 (2017)], the evolution of a hot magnetized plasma in contact with a cold unmagnetized plasma, aiming to represent the hot spot and liner, respectively, was investigated in planar geometry. The analysis was made in a double limit low Mach and high thermal to magnetic pressure ratio β. In this paper, the analysis is extended to an arbitrary pressure ratio. Nernst, Ettingshausen, and Joule effects come into play in the energy balance. The region close to the liner is governed by thermal conduction, while the Joule dissipation becomes predominant far from it when the pressure ratio is low. Mass ablation, thermal energy, and magnetic flux losses are reduced with plasma magnetization, characterized by the electron Hall parameter ω e τ e , until β values of order unity are reached. From this point forward, increasing the electron Hall parameter no longer improves the magnetic flux conservation, and mass ablation is enhanced due to the magnetic pressure gradients. A thoughtful simplification of the problem that allows to reduce the order of the system of governing equations while still retaining the finite β effects is presented and compared to the exact case.

  18. Wayside Bearing Fault Diagnosis Based on a Data-Driven Doppler Effect Eliminator and Transient Model Analysis

    Science.gov (United States)

    Liu, Fang; Shen, Changqing; He, Qingbo; Zhang, Ao; Liu, Yongbin; Kong, Fanrang

    2014-01-01

    A fault diagnosis strategy based on the wayside acoustic monitoring technique is investigated for locomotive bearing fault diagnosis. Inspired by the transient modeling analysis method based on correlation filtering analysis, a so-called Parametric-Mother-Doppler-Wavelet (PMDW) is constructed with six parameters, including a center characteristic frequency and five kinematic model parameters. A Doppler effect eliminator containing a PMDW generator, a correlation filtering analysis module, and a signal resampler is invented to eliminate the Doppler effect embedded in the acoustic signal of the recorded bearing. Through the Doppler effect eliminator, the five kinematic model parameters can be identified based on the signal itself. Then, the signal resampler is applied to eliminate the Doppler effect using the identified parameters. With the ability to detect early bearing faults, the transient model analysis method is employed to detect localized bearing faults after the embedded Doppler effect is eliminated. The effectiveness of the proposed fault diagnosis strategy is verified via simulation studies and applications to diagnose locomotive roller bearing defects. PMID:24803197

  19. Effect of Delta-tetrahydrocannabinol, a cannabinoid receptor agonist, on the triggering of transient lower oesophageal sphincter relaxations in dogs and humans

    NARCIS (Netherlands)

    Beaumont, H.; Jensen, J.; Carlsson, A.; Ruth, M.; Lehmann, A.; Boeckxstaens, G. E.

    2009-01-01

    Background and purpose: Transient lower oesophageal sphincter relaxations (TLESRs) are the main mechanism underlying gastro-oesophageal reflux and are a potential pharmacological treatment target. We evaluated the effect of the CB(1)/CB(2) receptor agonist Delta(9)-tetrahydrocannabinol

  20. Biological interactions and human health effects of static magnetic fields

    International Nuclear Information System (INIS)

    Tenforde, T.S.

    1994-09-01

    Mechanisms through which static magnetic fields interact with living systems will be described and illustrated by selected experimental observations. These mechanisms include electrodynamic interactions with moving ionic charges (blood flow and nerve impulse conduction), magnetomechanical interactions (orientation and translation of molecular structures and magnetic particles), and interactions with electronic spin states in charge transfer reactions (photo-induced electron transfer in photosynthesis). A general summary will also be presented of the biological effects of static magnetic fields studied in the laboratory and in natural settings. One aspect of magnetic field effects that merits special concern is their influence on implanted medical electronic devices such as cardiac pacemakers. Several extensive studies have demonstrated closure of the reed switch in pacemakers exposed to relatively weak static magnetic fields, thereby causing them to revert to an asynchronous mode of operation that is potentially hazardous. Recommendations for human exposure limits are provided

  1. The effect of magnetic field induced aggregates on ultrasound propagation in aqueous magnetic fluid

    International Nuclear Information System (INIS)

    Parekh, Kinnari; Upadhyay, R.V.

    2017-01-01

    Ultrasonic wave propagation in the aqueous magnetic fluid is investigated for different particle concentrations. The sound velocity decreases while acoustic impedance increases with increasing concentrations. The velocity anisotropy is observed upon application of magnetic field. The velocity anisotropy fits with Tarapov’s theory suggests the presence of aggregates in the system. We report that these aggregates are thermodynamically unstable and the length of aggregate changes continuously with increasing concentration and, or magnetic field and resulted in a decrease in effective magnetic moment. The Taketomi's theory fits well with the experimental data suggesting that the particle clusters are aligned in the direction of the magnetic field. The radius of cluster found to increase with increasing concentration, and then decreases whereas the elastic force constant increases and then becomes constant. The increase in cluster radius indicates elongation of aggregate length due to tip-to-tip interaction of aggregates whereas for higher concentration, the lateral alignment is more favorable than tip-to-tip alignment of aggregates which reduces the cluster radius making elastic force constant to raise. Optical images show that the chains are fluctuating and confirming the lateral alignment of chains at higher fields. - Highlights: • Magnetic field induced aggregates investigated using ultrasonic wave in aqueous magnetic fluid. • Velocity anisotropy induces upon applications of magnetic field. • Tarapov’s theory fit shows reduction in effective magnetic moment as concentration increases. • Taketomi's theory shows alignment of clusters in field direction. • Cluster radius increases and then decreases with increasing volume fractions. • Optical images show that fluctuating chains and lateral alignment of chains at higher fields.

  2. The effect of magnetic field induced aggregates on ultrasound propagation in aqueous magnetic fluid

    Energy Technology Data Exchange (ETDEWEB)

    Parekh, Kinnari, E-mail: kinnariparekh.rnd@charusat.ac.in [Dr. KC Patel R& D Center, Charotar University of Science & Technology, Changa, 388421 Dist. Anand, Gujarat (India); Upadhyay, R.V. [PD Patel Institute of Applied Sciences, Charotar University of Science & Technology, Changa, 388421 Dist. Anand, Gujarat (India)

    2017-06-01

    Ultrasonic wave propagation in the aqueous magnetic fluid is investigated for different particle concentrations. The sound velocity decreases while acoustic impedance increases with increasing concentrations. The velocity anisotropy is observed upon application of magnetic field. The velocity anisotropy fits with Tarapov’s theory suggests the presence of aggregates in the system. We report that these aggregates are thermodynamically unstable and the length of aggregate changes continuously with increasing concentration and, or magnetic field and resulted in a decrease in effective magnetic moment. The Taketomi's theory fits well with the experimental data suggesting that the particle clusters are aligned in the direction of the magnetic field. The radius of cluster found to increase with increasing concentration, and then decreases whereas the elastic force constant increases and then becomes constant. The increase in cluster radius indicates elongation of aggregate length due to tip-to-tip interaction of aggregates whereas for higher concentration, the lateral alignment is more favorable than tip-to-tip alignment of aggregates which reduces the cluster radius making elastic force constant to raise. Optical images show that the chains are fluctuating and confirming the lateral alignment of chains at higher fields. - Highlights: • Magnetic field induced aggregates investigated using ultrasonic wave in aqueous magnetic fluid. • Velocity anisotropy induces upon applications of magnetic field. • Tarapov’s theory fit shows reduction in effective magnetic moment as concentration increases. • Taketomi's theory shows alignment of clusters in field direction. • Cluster radius increases and then decreases with increasing volume fractions. • Optical images show that fluctuating chains and lateral alignment of chains at higher fields.

  3. Magnetic effects in the paraxial regime of elastic electron scattering

    Science.gov (United States)

    Edström, Alexander; Lubk, Axel; Rusz, Ján

    2016-11-01

    Motivated by a recent claim [Phys. Rev. Lett. 116, 127203 (2016), 10.1103/PhysRevLett.116.127203] that electron vortex beams can be used to image magnetism at the nanoscale in elastic scattering experiments, using transmission electron microscopy, a comprehensive computational study is performed to study magnetic effects in the paraxial regime of elastic electron scattering in magnetic solids. Magnetic interactions from electron vortex beams, spin polarized electron beams, and beams with phase aberrations are considered, as they pass through ferromagnetic FePt or antiferromagnetic LaMnAsO. The magnetic signals are obtained by comparing the intensity over a disk in the diffraction plane for beams with opposite angular momentum or aberrations. The strongest magnetic signals are obtained from vortex beams with large orbital angular momentum, where relative magnetic signals above 10-3 are indicated for 10 ℏ orbital angular momentum, meaning that relative signals of one percent could be expected with the even larger orbital angular momenta, which have been produced in experimental setups. All results indicate that beams with low acceleration voltage and small convergence angles yield stronger magnetic signals, which is unfortunately problematic for the possibility of high spatial resolution imaging. Nevertheless, under atomic resolution conditions, relative magnetic signals in the order of 10-4 are demonstrated, corresponding to an increase with one order of magnitude compared to previous work.

  4. Effect of magnetic soft phase on the magnetic properties of bulk anisotropic Nd2Fe14B/α-Fe nanocomposite permanent magnets

    Science.gov (United States)

    Li, Yuqing; Yue, Ming; Zhao, Guoping; Zhang, Hongguo

    2018-01-01

    The effects of soft phase with different particle sizes and distributions on the Nd2Fe14B/α-Fe nanocomposite magnets have been studied by the micro-magnetism simulation. The calculated results show that smaller and/or scattered distribution of soft phase can benefit to the coercivity (H ci) of the nanocomposite magnets. The magnetization moment evolution during magnetic reversal is systematically analyzed. On the other hand, magnetic properties of anisotropic Nd-Fe-B/α-Fe nanocomposite magnets prepared by hot pressing and hot deformation methods also provide evidences for the calculated results.

  5. About the skin effect in transient regime; Sur l'effet de peau en regime transitoire

    Energy Technology Data Exchange (ETDEWEB)

    Podliasky, I.

    1957-06-15

    Whereas always more experimental devices are using a pulsed electric supply (the electromagnetic field is applied during few microseconds only), and whereas the studied phenomenon does not last more than few microseconds, this raises the question of the behaviour in transient regime of metallic circuits or of discharge in gases. In this technical note, the author addresses the case of sufficiently high and constant gas conductivity during the studied duration. Thus, he reports a theoretical study of the establishment of a current in a high-conductivity and large-radius cylinder, and more specifically the study of the behaviour of peripheral layers (in the neighbourhood of the metal-insulator separation)

  6. Effects of magnetic drift tangential to magnetic surfaces on neoclassical transport in non-axisymmetric plasmas

    International Nuclear Information System (INIS)

    Matsuoka, Seikichi; Satake, Shinsuke; Kanno, Ryutaro; Sugama, Hideo

    2015-01-01

    In evaluating neoclassical transport by radially local simulations, the magnetic drift tangential to a flux surface is usually ignored in order to keep the phase-space volume conservation. In this paper, effect of the tangential magnetic drift on the local neoclassical transport is investigated. To retain the effect of the tangential magnetic drift in the local treatment of neoclassical transport, a new local formulation for the drift kinetic simulation is developed. The compressibility of the phase-space volume caused by the tangential magnetic drift is regarded as a source term for the drift kinetic equation, which is solved by using a two-weight δf Monte Carlo method for non-Hamiltonian system [G. Hu and J. A. Krommes, Phys. Plasmas 1, 863 (1994)]. It is demonstrated that the effect of the drift is negligible for the neoclassical transport in tokamaks. In non-axisymmetric systems, however, the tangential magnetic drift substantially changes the dependence of the neoclassical transport on the radial electric field E r . The peaked behavior of the neoclassical radial fluxes around E r  =   0 observed in conventional local neoclassical transport simulations is removed by taking the tangential magnetic drift into account

  7. Effects of magnetic drift tangential to magnetic surfaces on neoclassical transport in non-axisymmetric plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Seikichi, E-mail: matsuoka@rist.or.jp [Research Organization for Information Science and Technology, 6F Kimec-Center Build., 1-5-2 Minatojima-minamimachi, Chuo-ku, Kobe 650-0047 (Japan); Satake, Shinsuke; Kanno, Ryutaro [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Department of Fusion Science, SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi-cho, Toki 509-5292 (Japan); Sugama, Hideo [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan)

    2015-07-15

    In evaluating neoclassical transport by radially local simulations, the magnetic drift tangential to a flux surface is usually ignored in order to keep the phase-space volume conservation. In this paper, effect of the tangential magnetic drift on the local neoclassical transport is investigated. To retain the effect of the tangential magnetic drift in the local treatment of neoclassical transport, a new local formulation for the drift kinetic simulation is developed. The compressibility of the phase-space volume caused by the tangential magnetic drift is regarded as a source term for the drift kinetic equation, which is solved by using a two-weight δf Monte Carlo method for non-Hamiltonian system [G. Hu and J. A. Krommes, Phys. Plasmas 1, 863 (1994)]. It is demonstrated that the effect of the drift is negligible for the neoclassical transport in tokamaks. In non-axisymmetric systems, however, the tangential magnetic drift substantially changes the dependence of the neoclassical transport on the radial electric field E{sub r}. The peaked behavior of the neoclassical radial fluxes around E{sub r }={sub  }0 observed in conventional local neoclassical transport simulations is removed by taking the tangential magnetic drift into account.

  8. Analysis of PM Magnetization Field Effects on the Unbalanced Magnetic Forces due to Rotor Eccentricity in BLDC Motors

    Directory of Open Access Journals (Sweden)

    S. Mahdiuon-Rad

    2013-08-01

    Full Text Available This paper investigates both static and dynamic eccentricities in single phase brushless DC (BLDC motors and analyzes the effect of the PM magnetization field on unbalanced magnetic forces acting on the rotor. Three common types of PM magnetization field patterns including radial, parallel and sinusoidal magnetizations are considered. In both static and dynamic eccentricities, harmonic components of the unbalanced magnetic forces on the rotor are extracted and analyzed. Based on simulation results, the magnetization fields that produce the lowest and highest unbalanced magnetic forces are determined in rotor eccentricity conditions.

  9. Analysis of saturation effects on the operation of magnetic-controlled switcher type FCL

    Directory of Open Access Journals (Sweden)

    Faramarz Faghihi

    2009-12-01

    Full Text Available With the extensive application of electrical power system, suppression of fault current limiter is an important subject that guarantees system security. The superconducting fault current limiters (SFCL have been expected as a possible type of power apparatus to reduce the fault current in the power system. The results shown that under normal state, the FCL has no obvious effect on the power system; under fault state, the current limiting inductance connected in the bias current will be inserted into the fault circuit to limit the fault current. By regulating the bias current, the FCL voltage loss under normal state and the fault current can be adjusted to prescribed level. This kind of SFCL used the nonlinear permeability of the magnetic core for create a sufficient impedance and The transient performance considering the magnetic saturation is analyzed by Preisach model. Preisach model that intrinsically satisfies nonlinear properties is used as the numerical method for analysis of saturation effects. It is able to identification isotropic and no isotropic behaviour. The main idea is to compute the magnetization vector in two steps independently, amplitude and phase. The described model yield results in qualitative agreement with the experimental results.

  10. Effect of alloying on the electronic structure and magnetic properties ...

    Indian Academy of Sciences (India)

    Unknown

    We analyse the effect of local environment and the hybridization between the constituent bands on the elec- tronic and magnetic ..... statements made earlier that although the augmented .... ics, Trieste, for the financial help through its Network.

  11. Correlation effects driven by reduced dimensionality in magnetic ...

    Indian Academy of Sciences (India)

    2015-06-02

    Jun 2, 2015 ... Keywords. Magnetic surface alloys; electronic structure; surface reconstructions; correlation ..... While atomic multiplet effects are not directly visible as fine structure, they ..... [19] W L O' Brien, J Zhang and B P Tonner, J. Phys.

  12. effect of brinkman number and magnetic field on laminar convection ...

    African Journals Online (AJOL)

    Joseph et al.

    Science World Journal Vol 12(No 4) 2017 ... Joule heating on the fully developed MHD flow with heat transfer .... fluid in a vertical parallel – plate with effect of magnetic field and ..... Plates Channel, Proceedings of the 2013 International.

  13. Mechanism of viscosity effect on magnetic island rotation

    Energy Technology Data Exchange (ETDEWEB)

    Mikhailovskii, A.B.; Konovalov, S.V. [Institute of Nuclear Fusion, Russian Research Centre ' Kurchatov Institute' , Kurchatov Sq., 1, Moscow (Russian Federation); Pustovitov, V.D. [National Inst. for Fusion Science, Toki, Gifu (Japan); Tsypin, V.S. [Institute of Physics, University of Sao Paulo, Rua do Matao, Travessa R, SP (Brazil)

    2000-04-01

    It is shown that plasma viscosity does not influence the magnetic island rotation directly. Nevertheless, it leads to nonstationarity of the plasma velocity. This nonstationarity is the reason of the viscosity effect on island rotation. (author)

  14. Solvent effects on the magnetic shielding of tertiary butyl alcohol

    African Journals Online (AJOL)

    )4 and tetramethyl ammonium cation N(CH3)4(+) have also been presented. KEY WORDS: Solvent effects, Magnetic shielding, Tertiary butyl alcohol, Tertiary butyl amine, Continuum solvation calculations, Chemical shift estimation methods

  15. Gravitomagnetic effects in conductor in applied magnetic field

    International Nuclear Information System (INIS)

    Ahmedov, B.J.; Karim, M.

    1999-11-01

    The electromagnetic measurements of general relativistic gravitomagnetic effects which can be performed within a conductor embedded in the space-time of slow rotating gravitational object in the presence of magnetic field are proposed. (author)

  16. Effects of geoduck (Panopea generosa) aquaculture on resident and transient macrofauna communities of Puget Sound, Washington, USA

    Science.gov (United States)

    Mcdonald, P. Sean; Galloway, Aaron W.E.; McPeek, Kathleen C.; VanBlaricom, Glenn R.

    2015-01-01

    aquaculture may attract some structure-associated transient species observed infrequently on reference beaches, and may displace other species that typically occur in areas lacking epibenthic structure. This study provides a first look at the effects of multiple phases of geoduck farming on macrofauna, and has important implications for the management of a rapidly expanding sector of the aquaculture industry.

  17. Ion motion in the current sheet with sheared magnetic field – Part 2: Non-adiabatic effects

    Directory of Open Access Journals (Sweden)

    A. V. Artemyev

    2013-10-01

    Full Text Available We investigate dynamics of charged particles in current sheets with the sheared magnetic field. In our previouspaper (Artemyev et al., 2013 we studied the particle motion in such magnetic field configurations on the basis of the quasi-adiabatic theory and conservation of the quasi-adiabatic invariant. In this paper we concentrate on violation of the adiabaticity due to jumps of this invariant and the corresponding effects of stochastization of a particle motion. We compare effects of geometrical and dynamical jumps, which occur due to the presence of the separatrix in the phase plane of charged particle motion. We show that due to the presence of the magnetic field shear, the average value of dynamical jumps is not equal to zero. This effect results in the decrease of the time interval necessary for stochastization of trapped particle motion. We investigate also the effect of the magnetic field shear on transient trajectories, which cross the current sheet boundaries. Presence of the magnetic field shear leads to the asymmetry of reflection and transition of particles in the current sheet. We discuss the possible influence of single-particle effects revealed in this paper on the current sheet structure and dynamics.

  18. Tunable delay time and Hartman effect in graphene magnetic barriers

    International Nuclear Information System (INIS)

    Ban, Yue; Wang, Lin-Jun; Chen, Xi

    2015-01-01

    Tunable group delay and Hartman effect have been investigated for massless Dirac electrons in graphene magnetic barriers. In the presence of magnetic field, dwell time is found to be equal to net group delay plus the group delay contributing from the lateral shifts. The group delay times are discussed in both cases of normal and oblique incidence, to clarify the nature of Hartman effect. In addition, the group delay in transmission can be modulated from subluminality to superluminality by adjusting the magnetic field, which may also lead to potential applications in graphene-based microelectronics

  19. Transient osteoporosis of hip

    Directory of Open Access Journals (Sweden)

    Mahesh M Choudhary

    2015-01-01

    Full Text Available We report a case of transient osteoporosis of the hip (TOH in a 50-year-old man including the clinical presentation, diagnostic studies, management, and clinical progress. TOH is a rare self-limiting condition that typically affects middle-aged men or, less frequently, women in the third trimester of pregnancy. Affected individuals present clinically with acute hip pain, limping gait, and limited ranges of hip motion. TOH may begin spontaneously or after a minor trauma. Radiographs are typically unremarkable but magnetic resonance (MR imaging studies yield findings consistent with bone marrow edema. TOH is referred to as regional migratory osteoporosis (RMO if it travels to other joints or the contralateral hip. TOH often resembles osteonecrosis but the two conditions must be differentiated due to different prognoses and management approaches. The term TOH is often used interchangeably and synonymously with transient bone marrow edema (TBME.

  20. Transient hypofrontality as a mechanism for the psychological effects of exercise.

    Science.gov (United States)

    Dietrich, Arne

    2006-11-29

    Although exercise is known to promote mental health, a satisfactory understanding of the mechanism underlying this phenomenon has not yet been achieved. A new mechanism is proposed that is based on established concepts in cognitive psychology and the neurosciences as well as recent empirical work on the functional neuroanatomy of higher mental processes. Building on the fundamental principle that processing in the brain is competitive and the fact that the brain has finite metabolic resources, the transient hypofrontality hypothesis suggests that during exercise the extensive neural activation required to run motor patterns, assimilate sensory inputs, and coordinate autonomic regulation results in a concomitant transient decrease of neural activity in brain structures, such as the prefrontal cortex, that are not pertinent to performing the exercise. An exercise-induced state of frontal hypofunction can provide a coherent account of the influences of exercise on emotion and cognition. The new hypothesis is proposed primarily on the strength of its heuristic value, as it suggests several new avenues of research.

  1. Development of a simplified calculational model for the transient core bowing effect

    International Nuclear Information System (INIS)

    Yokoo, Takeshi

    1997-01-01

    A simplified method to analyze the transient core radial deformation has been developed based on a model that calculates the shape of a single representative fuel assembly on the outermost row. The plant transient code CERES has been revised utilizing this method so that a integrated calculational process for the core neutronics, thermal-hydraulics and deformation can be realized. Using CERES, the responses of a 1000MWe class pool type metal fuel FBR plant during a ULOF event are calculated. According to the results, it is clarified that a passive shutdown without coolant boiling is attainable by selecting appropriate values for major design parameters such as the gap width between load-pad and the pad material properties. The maximum coolant temperature during ULOF is found to be 790C when the above core load-pad gap is set to 0.05 mm, which can be regarded as the most likely valued. The temperature increases to 915C but is still lower than the boiling point when 40% of uncertainty is taken into account. (author)

  2. Effects of 1,25-Dihydroxycholecalciferol on Recovery and Resolution of Late Transient Neonatal Hypocalcemia

    Directory of Open Access Journals (Sweden)

    McKay SiripoomV

    2010-03-01

    Full Text Available Background. Late transient neonatal hypocalcemia with hyperphosphatemia is potentially life-threatening. The use of dihydroxycholecalciferol in the management of neonatal hypocalcemia is unexplored. Objective. We hypothesized adding dihydroxycholecalciferol to intravenous continuous calcium infusion (CaI will achieve accelerated correction of hypocalcemia. Design/Methods. A controlled double-blind randomized placebo group was organized to compare the addition of dihydroxycholecalciferol to CaI in 3–14 day old neonates presenting with hypocalcemia, hyperphosphatemia and seizures. Ionized calcium and phosphorus were measured to adjust CaI and maintain eucalcemia. Time to resolution of hypocalcemia was defined as time from starting CaI to the first ionized calcium of  mmol/L. CaI was discontinued when ionized calcium levels were  mmol/L on two measurements and the infant tolerated feeds. Results. Fourteen neonates were studied without statistical difference between groups. Time to correction of hypocalcemia for 1,25 dihydroxycholecalciferol versus placebo was versus hours respectively (. The duration of CaI was versus hours respectively (. Conclusions. The addition of dihydroxycholecalciferol to standard CaI therapy reduced the duration of CaI, but did not reduce the time to correct hypocalcemia in neonates with late transient hypocalcemia.

  3. Radiation effects on bifurcation and dual solutions in transient natural convection in a horizontal annulus

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Kang; Yi, Hong-Liang, E-mail: yihongliang@hit.edu.cn; Tan, He-Ping, E-mail: tanheping@hit.edu.cn [School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2014-05-15

    Transitions and bifurcations of transient natural convection in a horizontal annulus with radiatively participating medium are numerically investigated using the coupled lattice Boltzmann and direct collocation meshless (LB-DCM) method. As a hybrid approach based on a common multi-scale Boltzmann-type model, the LB-DCM scheme is easy to implement and has an excellent flexibility in dealing with the irregular geometries. Separate particle distribution functions in the LBM are used to calculate the density field, the velocity field and the thermal field. In the radiatively participating medium, the contribution of thermal radiation to natural convection must be taken into account, and it is considered as a radiative term in the energy equation that is solved by the meshless method with moving least-squares (MLS) approximation. The occurrence of various instabilities and bifurcative phenomena is analyzed for different Rayleigh number Ra and Prandtl number Pr with and without radiation. Then, bifurcation diagrams and dual solutions are presented for relevant radiative parameters, such as convection-radiation parameter Rc and optical thickness τ. Numerical results show that the presence of volumetric radiation changes the static temperature gradient of the fluid, and generally results in an increase in the flow critical value. Besides, the existence and development of dual solutions of transient convection in the presence of radiation are greatly affected by radiative parameters. Finally, the advantage of LB-DCM combination is discussed, and the potential benefits of applying the LB-DCM method to multi-field coupling problems are demonstrated.

  4. The effect of sea-ice on the transient atmospheric eddies of the Southern Hemisphere

    Energy Technology Data Exchange (ETDEWEB)

    Menendez, C.G. [Centro de Investigaciones del Mar y la Atmosfera/CONICET-UBA, Buenos Aires (Argentina); Serafini, V.; Le Treut, H. [Laboratoire de Meteorologie Dynamique/CNRS, Universite P. et M. Curie, Tour 15-25, 4 place Jussieu, 75252 Paris Cedex 05 (France)

    1999-09-01

    Two 10 y simulations with a full seasonal cycle and 96 x 72 x 19 resolution were carried out with a version of the LMD GCM to diagnose the role of sea-ice on the extratropical climatology of the Southern Hemisphere. The control integration used the usual observed sea-ice distribution, while the anomaly simulation imposed a scenario in which all sea-ice was entirely replaced by open ocean. The simulated control climate was compared with available observational-based analyses. Relevant diagnostics of the time mean and indicators of the transient eddy activity have been evaluated for both integrations. The impact was shown throughout the troposphere and was larger and more organised in winter. We found reduced westerly flow and both falls and rises in sea level pressure in the region from which sea-ice was removed. The removal of ice in the Southern Ocean affects the baroclinic structure of the atmosphere. Changes in baroclinicity and eddy activity are consistent with changes in the mean climate. In general, the meridional wind variance, the poleward transient temperature flux and the eddy flux convergence of westerly momentum were weaker over the Southern Ocean. However, a strengthening of the variance downstream of the subtropical jet was found. The position of the main storm track tends to be slightly displaced equatorward in the anomaly case. (orig.) With 15 figs., 53 refs.

  5. Improving the spatial resolution in CZT detectors using charge sharing effect and transient signal analysis: Simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Xiaoqing; Cheng, Zeng [Department of Electrical and Computer Engineering, McMaster University (Canada); Deen, M. Jamal, E-mail: jamal@mcmaster.ca [Department of Electrical and Computer Engineering, McMaster University (Canada); School of Biomedical Engineering, McMaster University (Canada); Peng, Hao, E-mail: penghao@mcmaster.ca [Department of Electrical and Computer Engineering, McMaster University (Canada); School of Biomedical Engineering, McMaster University (Canada); Department of Medical Physics, McMaster University, Ontario L8S 4K1, Hamilton (Canada)

    2016-02-01

    Cadmium Zinc Telluride (CZT) semiconductor detectors are capable of providing superior energy resolution and three-dimensional position information of gamma ray interactions in a large variety of fields, including nuclear physics, gamma-ray imaging and nuclear medicine. Some dedicated Positron Emission Tomography (PET) systems, for example, for breast cancer detection, require higher contrast recovery and more accurate event location compared with a whole-body PET system. The spatial resolution is currently limited by electrode pitch in CZT detectors. A straightforward approach to increase the spatial resolution is by decreasing the detector electrode pitch, but this leads to higher fabrication cost and a larger number of readout channels. In addition, inter-electrode charge spreading can negate any improvement in spatial resolution. In this work, we studied the feasibility of achieving sub-pitch spatial resolution in CZT detectors using two methods: charge sharing effect and transient signal analysis. We noted that their valid ranges of usage were complementary. The dependences of their corresponding valid ranges on electrode design, depth-of-interaction (DOI), voltage bias and signal triggering threshold were investigated. The implementation of these two methods in both pixelated and cross-strip configuration of CZT detectors were discussed. Our results show that the valid range of charge sharing effect increases as a function of DOI, but decreases with increasing gap width and bias voltage. For a CZT detector of 5 mm thickness, 100 µm gap and biased at 400 V, the valid range of charge sharing effect was found to be about 112.3 µm around the gap center. This result complements the valid range of the transient signal analysis within one electrode pitch. For a signal-to-noise ratio (SNR) of ~17 and preliminary measurements, the sub-pitch spatial resolution is expected to be ~30 µm and ~250 µm for the charge sharing and transient signal analysis methods

  6. Effect of alignment of easy axes on dynamic magnetization of immobilized magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Takashi, E-mail: t_yoshi@ees.kyushu-u.ac.jp [Department of Electrical and Electronic Engineering, Kyushu University, Fukuoka 819-0395 (Japan); Matsugi, Yuki; Tsujimura, Naotaka; Sasayama, Teruyoshi; Enpuku, Keiji [Department of Electrical and Electronic Engineering, Kyushu University, Fukuoka 819-0395 (Japan); Viereck, Thilo; Schilling, Meinhard; Ludwig, Frank [Institut für Elektrische Messtechnik und Grundlagen der Elektrotechnik, TU Braunschweig, Braunschweig 38106 (Germany)

    2017-04-01

    In some biomedical applications of magnetic nanoparticles (MNPs), the particles are physically immobilized. In this study, we explore the effect of the alignment of the magnetic easy axes on the dynamic magnetization of immobilized MNPs under an AC excitation field. We prepared three immobilized MNP samples: (1) a sample in which easy axes are randomly oriented, (2) a parallel-aligned sample in which easy axes are parallel to the AC field, and (3) an orthogonally aligned sample in which easy axes are perpendicular to the AC field. First, we show that the parallel-aligned sample has the largest hysteresis in the magnetization curve and the largest harmonic magnetization spectra, followed by the randomly oriented and orthogonally aligned samples. For example, 1.6-fold increase was observed in the area of the hysteresis loop of the parallel-aligned sample compared to that of the randomly oriented sample. To quantitatively discuss the experimental results, we perform a numerical simulation based on a Fokker-Planck equation, in which probability distributions for the directions of the easy axes are taken into account in simulating the prepared MNP samples. We obtained quantitative agreement between experiment and simulation. These results indicate that the dynamic magnetization of immobilized MNPs is significantly affected by the alignment of the easy axes. - Highlights: • We clarify how the alignment of easy axis of MNP affects the AC magnetization. • Parallel-aligned immobilized MNPs exhibit the largest AC hysteresis loop. • Parallel-aligned immobilized MNPs exhibit the largest harmonic magnetization spectra. • The AC magnetization is strongly affected by the alignment of the easy axes.

  7. Neuroprotective effect of safranal, an active ingredient of Crocus sativus , in a rat model of transient cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Hamid R. Sadeghnia

    2017-09-01

    Full Text Available Safranal is a monoterpene aldehyde found in saffron (Crocus sativus L. petals. It has been previously reported that safranal has a wide range of activities such as antioxidant and anti-inflammatory effects. In this study, we examined the effect of safranal on brain injuries in a transient model of focal cerebral ischemia. Transient focal cerebral ischemia was induced by middle cerebral artery occlusion for 30 min, followed by 24 h of reperfusion. Safranal in the doses of 72.5 and 145 mg/kg was administered intraperitoneally at 0, 3, and 6 h after reperfusion. Neurobehavioral deficit, infarct volume, hippocampal cell loss and markers of oxidative stress including thiobarbituric acid reactive substances (TBARS, total sulfhydryl (SH content, and antioxidant capacity (using FRAP assay were also assessed. The focal cerebral ischemia induced a significant increase in the neurological score, infarct volume and neuronal cell loss in the ipsilateral hippocampal CA1 and CA3 subfields (p < 0.001 and also oxidative stress markers (p < 0.01. Following safranal administration, the total SH content and antioxidant capacity significantly increased, while marked decreases were observed in the neurological score, infarct volume and hippocampal cell loss, as well as TBARS level. This study concluded that safranal had protective effects on ischemic reperfusion injury in the rat model of stroke. Such effects of safranal may have been exerted mainly by suppressing the production of free radicals and increasing antioxidant activity.

  8. A theory for the anisotropic interaction between two substitutional magnetic impurities and the magnetic anisotropic effect in dilute magnetic alloys

    International Nuclear Information System (INIS)

    Satter, M.A.

    1990-08-01

    In this paper, a formalism for studying the anisotropic interaction between two substitutional magnetic impurities and the magnetic anisotropic effect in a dilute noble metal- transition metal magnetic alloy has been developed from relativistic scattering theory. The theoretical development and the computational techniques of this formalism are based on relativistic spin-polarized scattering theory and relativistic band structure frameworks. For studying the magnetic anisotropic effect a convenient ''working'' frame of reference with its axes oriented along the fcc crystal axes is set up. This formalism is applied to study the situation for two Fe impurities in paramagnetic Au hosts. For AuFe dilute alloy, the two impurity site interaction as a function of separation is not oscillatory and the anisotropic effect is found to be less than the two site interaction itself only by an order of magnitude. Apart from the anisotropic coupling of the two impurity spins to the separation vector, for the first time, another weak anisotropic coupling to the crystal axes is also contained in the two site interaction. These anisotropic effects are the results of the relativistic spin-orbit interaction which are incorporated into the formalism. (author). 22 refs, 5 figs

  9. Spin polarization and magnetic effects in radical reactions

    International Nuclear Information System (INIS)

    Salikhov, K.M.; Molin, Yu.N.; Sagdeev, R.Z.; Buchachenko, A.L.

    1984-01-01

    Studies on the effects of chemically induced dynamic nuclear and electron polarizations (CIDNP and CIDEP), and magnetic effects in radical reactions, have given rise to a new rapidly-progressing field of chemical physics. It came into being about ten years ago and has been attracting the ever-growing attention of researchers in related areas. The present book is a fairly all-embracing review of the state of affairs in this field. The book presents the physical background (both theoretical and experimental) of CIDNP and CIDEP, of the effects of an external magnetic field and magnetic nuclear moment (magnetic isotope effects) on radical reactions in solutions. Great attention has been paid to the application of chemical spin polarization and magnetic effects to solving various problems of chemical kinetics, structural chemistry, molecular physics, magnetobiology, and radiospectroscopy. The book will be useful for physicists, chemists and biologists employing CIDNP, CIDEP and magnetic effects in their investigations, as well as for researchers in related fields of chemical physics. The book can be also recommended for postgraduates and senior undergraduate students. (Auth.)

  10. Interaction mechanisms and biological effects of static magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Tenforde, T.S.

    1994-06-01

    Mechanisms through which static magnetic fields interact with living systems are described and illustrated by selected experimental observations. These mechanisms include electrodynamic interactions with moving, ionic charges (blood flow and nerve impulse conduction), magnetomechanical interactions (orientation and translation of molecules structures and magnetic particles), and interactions with electronic spin states in charge transfer reactions (photo-induced electron transfer in photosynthesis). A general summary is also presented of the biological effects of static magnetic fields. There is convincing experimental evidence for magnetoreception mechanisms in several classes of lower organisms, including bacteria and marine organisms. However, in more highly evolved species of animals, there is no evidence that the interactions of static magnetic fields with flux densities up to 2 Tesla (1 Tesla [T] = 10{sup 4} Gauss) produce either behavioral or physiolocical alterations. These results, based on controlled studies with laboratory animals, are consistent with the outcome of recent epidemiological surveys on human populations exposed occupationally to static magnetic fields.

  11. Kinetic modeling of Nernst effect in magnetized hohlraums.

    Science.gov (United States)

    Joglekar, A S; Ridgers, C P; Kingham, R J; Thomas, A G R

    2016-04-01

    We present nanosecond time-scale Vlasov-Fokker-Planck-Maxwell modeling of magnetized plasma transport and dynamics in a hohlraum with an applied external magnetic field, under conditions similar to recent experiments. Self-consistent modeling of the kinetic electron momentum equation allows for a complete treatment of the heat flow equation and Ohm's law, including Nernst advection of magnetic fields. In addition to showing the prevalence of nonlocal behavior, we demonstrate that effects such as anomalous heat flow are induced by inverse bremsstrahlung heating. We show magnetic field amplification up to a factor of 3 from Nernst compression into the hohlraum wall. The magnetic field is also expelled towards the hohlraum axis due to Nernst advection faster than frozen-in flux would suggest. Nonlocality contributes to the heat flow towards the hohlraum axis and results in an augmented Nernst advection mechanism that is included self-consistently through kinetic modeling.

  12. Phase separation in La-Ca manganites: Magnetic field effects

    International Nuclear Information System (INIS)

    Tovar, M.; Causa, M.T.; Ramos, C.A.; Laura-Ccahuana, D.

    2008-01-01

    The coexistence of magnetic phases seems to be a characteristic of the La-Ca family of in colossal magnetoresistant manganites. We have analyzed this phenomenon in terms of a free energy, F, where magnetic and electronic contributions of two coexistent phases are included. Three order parameters describe the behavior of the mixed material: the magnetization of each phase and the metallic fraction. Due to the coupling between order parameters there is a range: T**≤T≤T* where coexistence is possible. Values for the phenomenological parameters are obtained from the experiment. In this paper we analyze the effects of an applied magnetic field on the range of T where the phase coexistence takes place, based on results obtained from dc-magnetization and ESR measurements

  13. Quantum Hall effect in epitaxial graphene with permanent magnets.

    Science.gov (United States)

    Parmentier, F D; Cazimajou, T; Sekine, Y; Hibino, H; Irie, H; Glattli, D C; Kumada, N; Roulleau, P

    2016-12-06

    We have observed the well-kown quantum Hall effect (QHE) in epitaxial graphene grown on silicon carbide (SiC) by using, for the first time, only commercial NdFeB permanent magnets at low temperature. The relatively large and homogeneous magnetic field generated by the magnets, together with the high quality of the epitaxial graphene films, enables the formation of well-developed quantum Hall states at Landau level filling factors v = ±2, commonly observed with superconducting electro-magnets. Furthermore, the chirality of the QHE edge channels can be changed by a top gate. These results demonstrate that basic QHE physics are experimentally accessible in graphene for a fraction of the price of conventional setups using superconducting magnets, which greatly increases the potential of the QHE in graphene for research and applications.

  14. Phase separation in La-Ca manganites: Magnetic field effects

    Energy Technology Data Exchange (ETDEWEB)

    Tovar, M; Causa, M T [Centro Atomico Bariloche and Instituto Balseiro, Comision Nacional de Energia Atomica and Universidad Nacional de Cuyo, 8400 San Carlos de Bariloche, Rio Negro (Argentina); Ramos, C.A. [Centro Atomico Bariloche and Instituto Balseiro, Comision Nacional de Energia Atomica and Universidad Nacional de Cuyo, 8400 San Carlos de Bariloche, Rio Negro (Argentina)], E-mail: cramos@cab.cnea.gov.ar; Laura-Ccahuana, D [Centro Atomico Bariloche and Instituto Balseiro, Comision Nacional de Energia Atomica and Universidad Nacional de Cuyo, 8400 San Carlos de Bariloche, Rio Negro (Argentina); Universidad Nacional de Ingenieria, Av. Tupac Amaru 210, Rimac/Lima 25 (Peru)

    2008-02-15

    The coexistence of magnetic phases seems to be a characteristic of the La-Ca family of in colossal magnetoresistant manganites. We have analyzed this phenomenon in terms of a free energy, F, where magnetic and electronic contributions of two coexistent phases are included. Three order parameters describe the behavior of the mixed material: the magnetization of each phase and the metallic fraction. Due to the coupling between order parameters there is a range: T**{<=}T{<=}T* where coexistence is possible. Values for the phenomenological parameters are obtained from the experiment. In this paper we analyze the effects of an applied magnetic field on the range of T where the phase coexistence takes place, based on results obtained from dc-magnetization and ESR measurements.

  15. Quantum Hall effect in epitaxial graphene with permanent magnets

    Science.gov (United States)

    Parmentier, F. D.; Cazimajou, T.; Sekine, Y.; Hibino, H.; Irie, H.; Glattli, D. C.; Kumada, N.; Roulleau, P.

    2016-12-01

    We have observed the well-kown quantum Hall effect (QHE) in epitaxial graphene grown on silicon carbide (SiC) by using, for the first time, only commercial NdFeB permanent magnets at low temperature. The relatively large and homogeneous magnetic field generated by the magnets, together with the high quality of the epitaxial graphene films, enables the formation of well-developed quantum Hall states at Landau level filling factors v = ±2, commonly observed with superconducting electro-magnets. Furthermore, the chirality of the QHE edge channels can be changed by a top gate. These results demonstrate that basic QHE physics are experimentally accessible in graphene for a fraction of the price of conventional setups using superconducting magnets, which greatly increases the potential of the QHE in graphene for research and applications.

  16. Effective particle magnetic moment of multi-core particles

    International Nuclear Information System (INIS)

    Ahrentorp, Fredrik; Astalan, Andrea; Blomgren, Jakob; Jonasson, Christian; Wetterskog, Erik; Svedlindh, Peter; Lak, Aidin; Ludwig, Frank; IJzendoorn, Leo J. van; Westphal, Fritz; Grüttner, Cordula; Gehrke, Nicole; Gustafsson, Stefan; Olsson, Eva; Johansson, Christer

    2015-01-01

    In this study we investigate the magnetic behavior of magnetic multi-core particles and the differences in the magnetic properties of multi-core and single-core nanoparticles and correlate the results with the nanostructure of the different particles as determined from transmission electron microscopy (TEM). We also investigate how the effective particle magnetic moment is coupled to the individual moments of the single-domain nanocrystals by using different measurement techniques: DC magnetometry, AC susceptometry, dynamic light scattering and TEM. We have studied two magnetic multi-core particle systems – BNF Starch from Micromod with a median particle diameter of 100 nm and FeraSpin R from nanoPET with a median particle diameter of 70 nm – and one single-core particle system – SHP25 from Ocean NanoTech with a median particle core diameter of 25 nm

  17. Effective particle magnetic moment of multi-core particles

    Science.gov (United States)

    Ahrentorp, Fredrik; Astalan, Andrea; Blomgren, Jakob; Jonasson, Christian; Wetterskog, Erik; Svedlindh, Peter; Lak, Aidin; Ludwig, Frank; van IJzendoorn, Leo J.; Westphal, Fritz; Grüttner, Cordula; Gehrke, Nicole; Gustafsson, Stefan; Olsson, Eva; Johansson, Christer

    2015-04-01

    In this study we investigate the magnetic behavior of magnetic multi-core particles and the differences in the magnetic properties of multi-core and single-core nanoparticles and correlate the results with the nanostructure of the different particles as determined from transmission electron microscopy (TEM). We also investigate how the effective particle magnetic moment is coupled to the individual moments of the single-domain nanocrystals by using different measurement techniques: DC magnetometry, AC susceptometry, dynamic light scattering and TEM. We have studied two magnetic multi-core particle systems - BNF Starch from Micromod with a median particle diameter of 100 nm and FeraSpin R from nanoPET with a median particle diameter of 70 nm - and one single-core particle system - SHP25 from Ocean NanoTech with a median particle core diameter of 25 nm.

  18. Effective particle magnetic moment of multi-core particles

    Energy Technology Data Exchange (ETDEWEB)

    Ahrentorp, Fredrik; Astalan, Andrea; Blomgren, Jakob; Jonasson, Christian [Acreo Swedish ICT AB, Arvid Hedvalls backe 4, SE-411 33 Göteborg (Sweden); Wetterskog, Erik; Svedlindh, Peter [Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21 Uppsala (Sweden); Lak, Aidin; Ludwig, Frank [Institute of Electrical Measurement and Fundamental Electrical Engineering, TU Braunschweig, D‐38106 Braunschweig Germany (Germany); IJzendoorn, Leo J. van [Department of Applied Physics, Eindhoven University of Technology, 5600 MB Eindhoven (Netherlands); Westphal, Fritz; Grüttner, Cordula [Micromod Partikeltechnologie GmbH, D ‐18119 Rostock (Germany); Gehrke, Nicole [nanoPET Pharma GmbH, D ‐10115 Berlin Germany (Germany); Gustafsson, Stefan; Olsson, Eva [Department of Applied Physics, Chalmers University of Technology, SE-412 96 Göteborg (Sweden); Johansson, Christer, E-mail: christer.johansson@acreo.se [Acreo Swedish ICT AB, Arvid Hedvalls backe 4, SE-411 33 Göteborg (Sweden)

    2015-04-15

    In this study we investigate the magnetic behavior of magnetic multi-core particles and the differences in the magnetic properties of multi-core and single-core nanoparticles and correlate the results with the nanostructure of the different particles as determined from transmission electron microscopy (TEM). We also investigate how the effective particle magnetic moment is coupled to the individual moments of the single-domain nanocrystals by using different measurement techniques: DC magnetometry, AC susceptometry, dynamic light scattering and TEM. We have studied two magnetic multi-core particle systems – BNF Starch from Micromod with a median particle diameter of 100 nm and FeraSpin R from nanoPET with a median particle diameter of 70 nm – and one single-core particle system – SHP25 from Ocean NanoTech with a median particle core diameter of 25 nm.

  19. Effect of centrifugation on dynamic susceptibility of magnetic fluids

    International Nuclear Information System (INIS)

    Pshenichnikov, Alexander; Lebedev, Alexander; Lakhtina, Ekaterina; Kuznetsov, Andrey

    2017-01-01

    Highlights: • Six samples of magnetic fluid were obtained by centrifuging two base ferrocolloids. • Aggregates in magnetic fluids are main reason of dynamic susceptibility dispersion. • Centrifugation is an effective way of changing the dynamic susceptibility. - Abstract: The dispersive composition, dynamic susceptibility and spectrum of times of magnetization relaxation for six samples of magnetic fluid obtained by centrifuging two base colloidal solutions of the magnetite in kerosene was investigated experimentally. The base solutions differed by the concentration of the magnetic phase and the width of the particle size distribution. The procedure of cluster analysis allowing one to estimate the characteristic sizes of aggregates with uncompensated magnetic moments was described. The results of the magnetogranulometric and cluster analyses were discussed. It was shown that centrifugation has a strong effect on the physical properties of the separated fractions, which is related to the spatial redistribution of particles and multi-particle aggregates. The presence of aggregates in magnetic fluids is interpreted as the main reason of low-frequency (0.1–10 kHz) dispersion of the dynamic susceptibility. The obtained results count in favor of using centrifugation as an effective means of changing the dynamic susceptibility over wide limits and obtaining fluids with the specified type of susceptibility dispersion.

  20. Effect of centrifugation on dynamic susceptibility of magnetic fluids

    Energy Technology Data Exchange (ETDEWEB)

    Pshenichnikov, Alexander, E-mail: pshenichnikov@icmm.ru; Lebedev, Alexander; Lakhtina, Ekaterina; Kuznetsov, Andrey

    2017-06-15

    Highlights: • Six samples of magnetic fluid were obtained by centrifuging two base ferrocolloids. • Aggregates in magnetic fluids are main reason of dynamic susceptibility dispersion. • Centrifugation is an effective way of changing the dynamic susceptibility. - Abstract: The dispersive composition, dynamic susceptibility and spectrum of times of magnetization relaxation for six samples of magnetic fluid obtained by centrifuging two base colloidal solutions of the magnetite in kerosene was investigated experimentally. The base solutions differed by the concentration of the magnetic phase and the width of the particle size distribution. The procedure of cluster analysis allowing one to estimate the characteristic sizes of aggregates with uncompensated magnetic moments was described. The results of the magnetogranulometric and cluster analyses were discussed. It was shown that centrifugation has a strong effect on the physical properties of the separated fractions, which is related to the spatial redistribution of particles and multi-particle aggregates. The presence of aggregates in magnetic fluids is interpreted as the main reason of low-frequency (0.1–10 kHz) dispersion of the dynamic susceptibility. The obtained results count in favor of using centrifugation as an effective means of changing the dynamic susceptibility over wide limits and obtaining fluids with the specified type of susceptibility dispersion.

  1. An investigation of the magnetic field of Transient Disturbances (TD) at the Earth's orbit, and a determination of solar sources of TD from their characteristics at R = 1 AU

    Science.gov (United States)

    Fainshtein, V. .G.; Kaigorodov, A. P.

    1995-01-01

    We have investigated and intercompared the typical features of the magnetic field of two types of solar wind transient disturbances with shock waves: the shock wave is accompanied by a magnetic cloud (MC), and the shock wave is followed by a region with bidirectional solar wind electron heat flux (BEHF), with no MC present. In this case, a separate study was made of the field features in two typical TD structures: in the region of impact-compressed solar wind between the shock wave and MC or BEHF, as well as in MC and BEHF. The study has provided new results on the influence of the ambient SW upon the TD magnetic field and the relationship between fields in various TD structures. A new test for the existence of interplanetary magnetic field draping around MC and BEHF is proposed and verified. It is concluded that the magnetic field configuration around MC is more adequately consistent with the concept of magnetic line draping than is the case around BEHF Two methods are proposed to infer the location of solar sources of TD from their characteristics at R = 1 AU.

  2. The effect of saturation magnetization of nanocatalyst and oscillating magnetic field for green urea synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Yahya, Noorhana, E-mail: noorhana_yahya@petronas.com.my; Alqasem, Bilal, E-mail: bilalalqasem@yahoo.com; Irfan, Muhammad; Qureshi, Saima; Rehman, Zia Ur; Shafie, Afza; Soleimani, Hassan

    2017-02-15

    Hematite and cupric oxide nanowires have been synthesized using the oxidation method for green urea production. Hematite nanowires were obtained by the oxidation of an iron wire at a temperature of 650 °C and ambient pressure in the presence of N{sub 2} and O{sub 2} gases. Cupric oxide nanowires were obtained by the same method at 700 °C, using a copper wire. The X-ray diffraction results show the formation of rhombohedral structure of α-Fe{sub 2}O{sub 3} and monoclinic phase of CuO. FE-SEM results reveal the formation of nanowires with dimensions ranging between 5–15 µm and 4–12 µm in length and a diametere ranging between 50–150 nm and 50–250 nm for α-Fe{sub 2}O{sub 3} and CuO respectively. The VSM results show that the saturation magnetization values for hematite and cupric oxide were 132.8700 and 0.0124 emu/g, respectively. The nanowires were used as catalyst for green urea synthesis in the presence of an oscillating and a static magnetic fields. The use of nanocatalyst with high saturation magnetization gives a higher yield of urea due to the increase in the singlet to triplet conversion. The highest yield of urea 11243 ppm was achieved by applying an oscillating magnetic field of frequency 0.5 MHz and using α-Fe{sub 2}O{sub 3} nanowires as nanocatalyst. - Highlights: • Effect of saturation magnetization of nanocatalyst on urea yield was investigated • Using nanocatalyst with high saturation magnetization value improved urea yield. • Effect of oscillating magnetic field frequency on the urea yield was investigated. • The highest urea yield was achieved by applying 0.5 MHz oscillating magnetic field.

  3. The effect of saturation magnetization of nanocatalyst and oscillating magnetic field for green urea synthesis

    International Nuclear Information System (INIS)

    Yahya, Noorhana; Alqasem, Bilal; Irfan, Muhammad; Qureshi, Saima; Rehman, Zia Ur; Shafie, Afza; Soleimani, Hassan

    2017-01-01

    Hematite and cupric oxide nanowires have been synthesized using the oxidation method for green urea production. Hematite nanowires were obtained by the oxidation of an iron wire at a temperature of 650 °C and ambient pressure in the presence of N 2 and O 2 gases. Cupric oxide nanowires were obtained by the same method at 700 °C, using a copper wire. The X-ray diffraction results show the formation of rhombohedral structure of α-Fe 2 O 3 and monoclinic phase of CuO. FE-SEM results reveal the formation of nanowires with dimensions ranging between 5–15 µm and 4–12 µm in length and a diametere ranging between 50–150 nm and 50–250 nm for α-Fe 2 O 3 and CuO respectively. The VSM results show that the saturation magnetization values for hematite and cupric oxide were 132.8700 and 0.0124 emu/g, respectively. The nanowires were used as catalyst for green urea synthesis in the presence of an oscillating and a static magnetic fields. The use of nanocatalyst with high saturation magnetization gives a higher yield of urea due to the increase in the singlet to triplet conversion. The highest yield of urea 11243 ppm was achieved by applying an oscillating magnetic field of frequency 0.5 MHz and using α-Fe 2 O 3 nanowires as nanocatalyst. - Highlights: • Effect of saturation magnetization of nanocatalyst on urea yield was investigated • Using nanocatalyst with high saturation magnetization value improved urea yield. • Effect of oscillating magnetic field frequency on the urea yield was investigated. • The highest urea yield was achieved by applying 0.5 MHz oscillating magnetic field.

  4. Is There a Magnet School Effect? Using Meta-Analysis to Explore Variation in Magnet School Success. CRESST Report 843

    Science.gov (United States)

    Wang, Jia; Schweig, Jonathan D.; Herman, Joan L.

    2014-01-01

    Magnet schools are one of the largest sectors of choice schools in the United States. In this study, we explored whether there is heterogeneity in magnet school effects on student achievement by examining the effectiveness of 24 recently funded magnet schools in 5 school districts across 4 states. We used a two-step analysis: First, separate…

  5. Effects of 3D Magnetic Perturbations on Toroidal Plasmas

    International Nuclear Information System (INIS)

    Callen, J.D.

    2010-01-01

    Full text: To lowest order tokamaks are two-dimensional (2D) axisymmetric magnetic systems. But small 3D magnetic perturbations (both externally applied and from plasma instabilities) have many interesting and useful effects on tokamak (and quasi-symmetric stellarator) plasmas. Plasma transport equations that include these effects, especially on diamagnetic-level toroidal plasma rotation, have recently been developed. The 3D magnetic perturbations and their plasma effects can be classified according to their toroidal mode number n: low n (1 to 5) resonant (q = m/n in plasma) and non-resonant fields, medium n (due to toroidal field ripple), and high n (due to microturbulence). This paper concentrates on low and medium n perturbations. Low n non-resonant magnetic fields induce a neoclassical toroidal viscosity (NTV) that damps toroidal plasma rotation throughout the plasma toward an offset flow in the counter-I p direction; recent tokamak experiments have confirmed and exploited these predictions by applying external low n non-resonant magnetic perturbations. Medium n perturbations have similar effects plus possible ripple trapping and resultant edge ion losses. A low n resonant magnetic field induces a toroidal plasma torque in the vicinity of the rational surface; when large enough it can stop plasma rotation there and lead to a locked mode, which often causes a plasma disruption. Externally applied 3D magnetic perturbations usually have many components; in the plasma their lowest n components are amplified by plasma responses, particularly at high beta. Low n plasma instabilities (e.g., NTMs, RWMs) cause additional 3D magnetic perturbations in tokamak plasmas; tearing modes can bifurcate the topology and form magnetic islands. Finally, multiple resonant magnetic perturbations (RMPs) can cause local magnetic stochasticity and influence H-mode edge pedestal transport. These various effects of 3D magnetic perturbations can be used to control the toroidal plasma

  6. Micromagnetic modeling of the effects of stress on magnetic properties

    International Nuclear Information System (INIS)

    Zhu, B.; Lo, C. C. H.; Lee, S. J.; Jiles, D. C.

    2001-01-01

    A micromagnetic model has been developed for investigating the effect of stress on the magnetic properties of thin films. This effect has been implemented by including the magnetoelastic energy term into the Landau - Lifshitz - Gilbert equation. Magnetization curves of a nickel film were calculated under both tensile and compressive stresses of various magnitudes applied along the field direction. The modeling results show that coercivity increased with increasing compressive stress while remanence decreased with increasing tensile stress. The results are in agreement with the experimental data in the literature and can be interpreted in terms of the effects of the applied stress on the irreversible rotation of magnetic moments during magnetization reversal under an applied field. [copyright] 2001 American Institute of Physics

  7. Transient flow combustion

    Science.gov (United States)

    Tacina, R. R.

    1984-01-01

    Non-steady combustion problems can result from engine sources such as accelerations, decelerations, nozzle adjustments, augmentor ignition, and air perturbations into and out of the compressor. Also non-steady combustion can be generated internally from combustion instability or self-induced oscillations. A premixed-prevaporized combustor would be particularly sensitive to flow transients because of its susceptability to flashback-autoignition and blowout. An experimental program, the Transient Flow Combustion Study is in progress to study the effects of air and fuel flow transients on a premixed-prevaporized combustor. Preliminary tests performed at an inlet air temperature of 600 K, a reference velocity of 30 m/s, and a pressure of 700 kPa. The airflow was reduced to 1/3 of its original value in a 40 ms ramp before flashback occurred. Ramping the airflow up has shown that blowout is more sensitive than flashback to flow transients. Blowout occurred with a 25 percent increase in airflow (at a constant fuel-air ratio) in a 20 ms ramp. Combustion resonance was found at some conditions and may be important in determining the effects of flow transients.

  8. DISK FORMATION IN MAGNETIZED CLOUDS ENABLED BY THE HALL EFFECT

    International Nuclear Information System (INIS)

    Krasnopolsky, Ruben; Shang, Hsien; Li Zhiyun

    2011-01-01

    Stars form in dense cores of molecular clouds that are observed to be significantly magnetized. A dynamically important magnetic field presents a significant obstacle to the formation of protostellar disks. Recent studies have shown that magnetic braking is strong enough to suppress the formation of rotationally supported disks in the ideal MHD limit. Whether non-ideal MHD effects can enable disk formation remains unsettled. We carry out a first study on how disk formation in magnetic clouds is modified by the Hall effect, the least explored of the three non-ideal MHD effects in star formation (the other two being ambipolar diffusion and Ohmic dissipation). For illustrative purposes, we consider a simplified problem of a non-self-gravitating, magnetized envelope collapsing onto a central protostar of fixed mass. We find that the Hall effect can spin up the inner part of the collapsing flow to Keplerian speed, producing a rotationally supported disk. The disk is generated through a Hall-induced magnetic torque. Disk formation occurs even when the envelope is initially non-rotating, provided that the Hall coefficient is large enough. When the magnetic field orientation is flipped, the direction of disk rotation is reversed as well. The implication is that the Hall effect can in principle produce both regularly rotating and counter-rotating disks around protostars. The Hall coefficient expected in dense cores is about one order of magnitude smaller than that needed for efficient spin-up in these models. We conclude that the Hall effect is an important factor to consider in studying the angular momentum evolution of magnetized star formation in general and disk formation in particular.

  9. Evidence of circadian and extended shift effects on reactor transient frequency

    International Nuclear Information System (INIS)

    Maloney, S.

    1992-01-01

    An extensive body of knowledge exists documenting the significant swings in error rates, perception, judgment, and overall alertness levels in the course of a day. The literature also demonstrates pronounced differences in performance levels whereby night workers routinely underperform day workers in any set of tasks. The performance split widens with task complexity. Rotating shift workers, such as nuclear power plant operators, have been shown to experience performance problems comparable to straight night workers. Finally, sleep research also documents that extended hours, such as the so-called 4-day work week, can undermine alertness levels, particularly in the last 2 to 3 h of a daily shift. These issues suggest that cyclical performance by shift workers may be evident in nuclear plant operators. This paper seeks evidence of such cyclical performance by examining operating transients at nuclear power plants involving human error

  10. Effect of load transients on SOFC operation—current reversal on loss of load

    Science.gov (United States)

    Gemmen, Randall S.; Johnson, Christopher D.

    The dynamics of solid oxide fuel cell (SOFC) operation have been considered previously, but mainly through the use of one-dimensional codes applied to co-flow fuel cell systems. In this paper several geometries are considered, including cross-flow, co-flow, and counter-flow. The details of the model are provided, and the model is compared with some initial experimental data. For parameters typical of SOFC operation, a variety of transient cases are investigated, including representative load increase and decrease and system shutdown. Of particular note for large load decrease conditions (e.g., shutdown) is the occurrence of reverse current over significant portions of the cell, starting from the moment of load loss up to the point where equilibrated conditions again provide positive current. Consideration is given as to when such reverse current conditions might most significantly impact the reliability of the cell.

  11. Effect of power oscillations on suppression pool heating during ATWS [Anticipated Transients Without Scram] conditions

    International Nuclear Information System (INIS)

    Wulff, W.; Cheng, H.S.; Mallen, A.N.

    1990-01-01

    Nine selected Anticipated Transients Without Scram (ATWS) have been simulated on the BNL Engineering Plant Analyzer (EPA), to determine how power and flow oscillations, similar to those that did or could have occurred at the LaSalle-2 boiling Water Reactor (BWR), could affect the rate of Pressure Suppression Pool heating. It has been determined that the pool can reach its temperature limit of 80 degree C in 4.3 min. after Turbine Trip without Bypass, if the feedwater pumps are not tripped. The pool will not reach its limit, if Boron is injected, even when oscillations are encountered. Simultaneous turbine and recirculation pump trips, introduced under stable conditions, can lead to instability. 2 refs., 17 figs., 9 tabs

  12. Vectorization of LWR transient analysis code RELAP5/MOD1 and its effect

    International Nuclear Information System (INIS)

    Ishiguro, Misako; Harada, Hiroo; Shinozawa, Naohisa; Naraoka, Ken-itsu

    1985-03-01

    The RELAP5/MOD1 is a large thermal-hydraulic code to analyze LWR LOCA and non-LOCA transients. The code originally was designed for use on a CDC Cyber-176. This report documents vectorization of the RELAP5/MOD1 code conducted for the purpose of efficient use of VP-100 (peak speed 250 MFLOPS, clock period 7.5 ns) at the JAERI. The code was vectorized using the junction and volume level parallelisms in the hydrodynamic calculations, and the heat-structure and heat-mesh level in the heat conduction calculations. The vectorized version runs as much as 2.4 to 2.8 times faster than the original scalar version, while the speedup ratio is dependent on the number of spactial cells included in the problem. (author)

  13. Effects of 1,25-Dihydroxycholecalciferol on Recovery and Resolution of Late Transient Neonatal Hypocalcemia

    Directory of Open Access Journals (Sweden)

    Lefkothea Karaviti

    2010-01-01

    Full Text Available Background. Late transient neonatal hypocalcemia with hyperphosphatemia is potentially life-threatening. The use of 1.25 dihydroxycholecalciferol in the management of neonatal hypocalcemia is unexplored. Objective. We hypothesized adding 1.25 dihydroxycholecalciferol to intravenous continuous calcium infusion (CaI will achieve accelerated correction of hypocalcemia. Design/Methods. A controlled double-blind randomized placebo group was organized to compare the addition of 1.25 dihydroxycholecalciferol to CaI in 3–14 day old neonates presenting with hypocalcemia, hyperphosphatemia and seizures. Ionized calcium and phosphorus were measured to adjust CaI and maintain eucalcemia. Time to resolution of hypocalcemia was defined as time from starting CaI to the first ionized calcium of ≥1.1 mmol/L. CaI was discontinued when ionized calcium levels were ≥1.1 mmol/L on two measurements and the infant tolerated feeds. Results. Fourteen neonates were studied without statistical difference between groups. Time to correction of hypocalcemia for 1,25 dihydroxycholecalciferol versus placebo was 7.2 ± 1.9 versus 11.5 ± 3.4 hours respectively (p=.26. The duration of CaI was 15.0 ± 1.5 versus 24.8 ± 4.4 hours respectively (p=.012. Conclusions. The addition of 1.25 dihydroxycholecalciferol to standard CaI therapy reduced the duration of CaI, but did not reduce the time to correct hypocalcemia in neonates with late transient hypocalcemia.

  14. Magnets

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    A magnet pole piece for an NMR imaging magnet is made of a plurality of magnetic wires with one end of each wire held in a non-magnetic spacer, the other ends of the wires being brought to a pinch, and connected to a magnetic core. The wires may be embedded in a synthetic resin and the magnetisation and uniformity thereof can be varied by adjusting the density of the wires at the spacer which forms the pole piece. (author)

  15. Simulation Research of Magnetic Constriction Effect and Controlling by Axial Magnetic Field of Vacuum Arc

    Institute of Scientific and Technical Information of China (English)

    王立军; 贾申利; 史宗谦; 荣命哲

    2005-01-01

    Based on magnetohydrodynamic (MHD) model of vacuum arc, the computer simulation of vacuum arc was carried out in this paper. In the MHD model, mass conservation equation,momentum conservation equations, energy conservation equations, generalized ohm's law and Maxwell equation were considered. MHD equations were calculated by numerical method, and the distribution of vacuum arc plasma parameters and current density were obtained. Simulation results showed that the magnetic constriction effect of vacuum arc is primarily caused by the Hall effect. In addition, the inhibition of axial magnetic field (AMF) on constriction of vacuum arc was calculated and analyzed.

  16. Internal Gravity Waves in the Magnetized Solar Atmosphere. I. Magnetic Field Effects

    Energy Technology Data Exchange (ETDEWEB)

    Vigeesh, G.; Steiner, O. [Kiepenheuer-Institut für Sonnenphysik, Schöneckstrasse 6, D-79104 Freiburg (Germany); Jackiewicz, J., E-mail: vigeesh@leibniz-kis.de [New Mexico State University, Department of Astronomy, P.O. Box 30001, MSC 4500, Las Cruces, NM 88003 (United States)

    2017-02-01

    Observations of the solar atmosphere show that internal gravity waves are generated by overshooting convection, but are suppressed at locations of magnetic flux, which is thought to be the result of mode conversion into magnetoacoustic waves. Here, we present a study of the acoustic-gravity wave spectrum emerging from a realistic, self-consistent simulation of solar (magneto)convection. A magnetic field free, hydrodynamic simulation and a magnetohydrodynamic (MHD) simulation with an initial, vertical, homogeneous field of 50 G flux density were carried out and compared with each other to highlight the effect of magnetic fields on the internal gravity wave propagation in the Sun’s atmosphere. We find that the internal gravity waves are absent or partially reflected back into the lower layers in the presence of magnetic fields and argue that the suppression is due to the coupling of internal gravity waves to slow magnetoacoustic waves still within the high- β region of the upper photosphere. The conversion to Alfvén waves is highly unlikely in our model because there is no strongly inclined magnetic field present. We argue that the suppression of internal waves observed within magnetic flux concentrations may also be due to nonlinear breaking of internal waves due to vortex flows that are ubiquitously present in the upper photosphere and the chromosphere.

  17. Effect of alignment of easy axes on dynamic magnetization of immobilized magnetic nanoparticles

    Science.gov (United States)

    Yoshida, Takashi; Matsugi, Yuki; Tsujimura, Naotaka; Sasayama, Teruyoshi; Enpuku, Keiji; Viereck, Thilo; Schilling, Meinhard; Ludwig, Frank

    2017-04-01

    In some biomedical applications of magnetic nanoparticles (MNPs), the particles are physically immobilized. In this study, we explore the effect of the alignment of the magnetic easy axes on the dynamic magnetization of immobilized MNPs under an AC excitation field. We prepared three immobilized MNP samples: (1) a sample in which easy axes are randomly oriented, (2) a parallel-aligned sample in which easy axes are parallel to the AC field, and (3) an orthogonally aligned sample in which easy axes are perpendicular to the AC field. First, we show that the parallel-aligned sample has the largest hysteresis in the magnetization curve and the largest harmonic magnetization spectra, followed by the randomly oriented and orthogonally aligned samples. For example, 1.6-fold increase was observed in the area of the hysteresis loop of the parallel-aligned sample compared to that of the randomly oriented sample. To quantitatively discuss the experimental results, we perform a numerical simulation based on a Fokker-Planck equation, in which probability distributions for the directions of the easy axes are taken into account in simulating the prepared MNP samples. We obtained quantitative agreement between experiment and simulation. These results indicate that the dynamic magnetization of immobilized MNPs is significantly affected by the alignment of the easy axes.

  18. Effect of a Sulphate Transient on the EAC Crack Growth Behaviour of Low-Alloy RPV Steels under Simulated BWR Operating Conditions (CASTOC WP 3, PSI Test 1)

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, S.; Seifert, H. P

    2002-03-01

    Within the CASTOC-project (5th EU FW programme), the environmentally-assisted crack (EAC) growth behaviour of low-alloy reactor pressure vessel (RPV) steels is experimentally investigated under simulated transient and steady-state boiling water reactor (BWR) power operation conditions by six European laboratories. Within WP 3 of this project, the Paul Scherrer Institut (PSI) investigates the effect of water chemistry transients on the EAC crack growth behaviour under periodical partial unloading (PPU) conditions. The present report is a summary of the first PSI test of WP 3 with a Na{sub 2}SO{sub 4} transient. In the first part of the report, the theoretical background on crack growth mechanisms, crack chemistry, mass transport and water chemistry transients as well as a brief literature survey on other water chemistry transient investigations is given. Furthermore, the experimental equipment and test procedure is presented, followed by a summary of the results of PSI test 1 of WP 3. Finally the results are discussed in detail and compared to literature data. In the first part of the experiment, an actively growing EAC crack was generated by PPU in oxygenated high-temperature, high-purity water (T = 288 {sup o}C, DO = 8 ppm, SO{sub 4}{sup 2-} < 0.6 ppb). Then a sulphate transient was applied. The duration ({approx} 300 h) and the amount of sulphate (SO{sub 4}{sup 2-} = 368 ppb) of the applied sulphate transient conservatively covered all sulphate transients, which might occur in BWR/normal water chemistry (NWC) practice. After the transient, outlet conductivity was lowered from ca. 1 {mu}S/cm to less than 0.15 {mu}S/cm within 2.6 h by a 'two-loop technique'. No accelerating effect of the sulphate transient on the EAC crack growth of both tested fracture mechanics specimens under highly oxidising BWR/NWC conditions was observed, making it impossible to deterrnine incubation or delay times. The EAC crack growth rates (CGR) before, during and after the

  19. Spin-accumulation effect in magnetic nano-bridge

    International Nuclear Information System (INIS)

    Khvalkovskii, A.V.; Zvezdin, A.A.; Zvezdin, K.A.; Pullini, D.; Perlo, P.

    2004-01-01

    Large values of magnetoresistance experimentally observed in magnetic nano-contacts and nano-wires are explained in terms of spin accumulation. The investigation of the spin-accumulation effect in magnetic nano-contacts (Phys. Rev. Lett. 82 (1999) 2923) and nano-bridges (JETP Lett. 75 (10) (2002) 613), which are considered to be very promising for various spintronic applications, is presented. The two-dimensional spin-diffusion problem in a magnetic nano-bridge is solved. Dependences of the specific resistance of the domain wall and of the distribution of non-equilibrium spin density on the nano-bridge geometry and the material parameters are obtained

  20. Highly Sensitive Flexible Magnetic Sensor Based on Anisotropic Magnetoresistance Effect.

    Science.gov (United States)

    Wang, Zhiguang; Wang, Xinjun; Li, Menghui; Gao, Yuan; Hu, Zhongqiang; Nan, Tianxiang; Liang, Xianfeng; Chen, Huaihao; Yang, Jia; Cash, Syd; Sun, Nian-Xiang

    2016-11-01

    A highly sensitive flexible magnetic sensor based on the anisotropic magnetoresistance effect is fabricated. A limit of detection of 150 nT is observed and excellent deformation stability is achieved after wrapping of the flexible sensor, with bending radii down to 5 mm. The flexible AMR sensor is used to read a magnetic pattern with a thickness of 10 μm that is formed by ferrite magnetic inks. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Magnetic field effects in Arabidopsis thaliana Cryptochrome-1

    DEFF Research Database (Denmark)

    Solov'yov, Ilia; Chandler, Danielle E.; Schulten, Klaus

    2007-01-01

    The ability of some animals, most notably migratory birds, to sense magnetic fields is still poorly understood. It has been suggested that this "magnetic sense" may be mediated by the blue light receptor protein cryptochrome, which is known to be localized in the retinas of migratory birds...... chemistry of this photoreduction process, which involves electron transfer from a chain of three tryptophans, can be modulated by the presence of a magnetic field in an effect known as the radical-pair mechanism. Here we present and analyze a model of the flavin-adenine-dinucleotide-tryptophan chain system...

  2. Effects of dipole magnet inhomogeneities on the beam ellipsoid

    International Nuclear Information System (INIS)

    Tsoupas, N.; Colman, J.; Levine, M.; McKenzie-Wilson, R.; Ward, T.; Grand, P.

    1986-01-01

    The RAYTRACE computer code has been modified to accept magnetic fields measured in the median plane of a dipole magnet. This modification allows one to study the effects of a non-ideal dipole magnet on the beam ellipsoid (as defined by the TRANSPORT code manual). The effects on the beam ellipsoid are due to: field inhomogeneities in the interior region of the dipole, and discrepancies from design conditions of the magnetic field values in the fringe field region. The results of the RAYTRACE code calculations based on experimentally measured fields will be compared with the results derived using both an ideal (no inhomogeneities) dipole with SCOFF boundaries and an ideal dipole with perfect (according to design) fringe fields

  3. Extraordinary Hall-effect in colloidal magnetic nanoparticle films

    Energy Technology Data Exchange (ETDEWEB)

    Ben Gur, Leah; Tirosh, Einat [School of Chemistry, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801 (Israel); Segal, Amir [School of Physics, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801 (Israel); Markovich, Gil, E-mail: gilmar@post.tau.ac.il [School of Chemistry, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801 (Israel); Gerber, Alexander, E-mail: gerber@post.tau.ac.il [School of Physics, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801 (Israel)

    2017-03-15

    Colloidal nickel nanoparticles (NPs) coated with polyvinylpyrrolidone (PVP) were synthesized. The nanoparticle dispersions were deposited on substrates and dried under mild heating to form conductive films. The films exhibited very small coercivity, nearly metallic conductivity, and a significant extraordinary Hall effect signal. This method could be useful for preparing simple, printed magnetic field sensors with the advantage of relatively high sensitivity around zero magnetic field, in contrast to magnetoresistive sensors, which have maximal field sensitivity away from zero magnetic field. - Highlights: • Ni nanoparticle ink capable of forming conductive films on drying. • The Ni nanoparticle films exhibit significant extraordinary Hall effect. • This system could be used for preparing printed magnetic field sensors integrated in 3D printed structures.

  4. Pressure effects on magnetism in the uranium and neptunium monopnictides

    International Nuclear Information System (INIS)

    Braithwaite, D.; Demuer, A.; Ichas, V.; Rebizant, J.; Spirlet, J.C.; Zwirner, S.; Vogt, O.

    1998-01-01

    The magnetic properties of the cubic NaCl uranium and neptunium monopnictides (UX, NpX; X=N, P, As, Sb, Bi) have been widely studied at ambient pressure. Properties ranging from itinerant to localized magnetism, and a variety of ordered magnetic structures have been observed. In particular the profusion of non-collinear double-k or triple-k structures is a consequence of strongly anisotropic exchange interactions. The application of pressure is a clean way of continuously varying the lattice parameter, and the exchange interactions, from one compound to another. A number of studies have been performed using different high pressure techniques. Some of the effects of pressure can be understood in a simple picture of a continuous variation of the lattice parameter, but some highly anomalous effects are also found which are discussed in relation to the possible nature of the magnetic interactions. (orig.)

  5. Diffusion affected magnetic field effect in exciplex fluorescence

    International Nuclear Information System (INIS)

    Burshtein, Anatoly I.; Ivanov, Anatoly I.

    2014-01-01

    The fluorescence of the exciplex, 1 [D +δ A −δ ], formed at contact of photoexcited acceptor 1 A * with an electron donor 1 D, is known to be very sensitive to an external magnetic field, reducing the spin conversion efficiency in the resulting geminate radical ion pair, 1,3 [D + …A − ]. The relative increase of the exciplex fluorescence in the highest magnetic field compared to the lowest one, known as the magnetic field effect, crucially depends on the viscosity of the solvent. This phenomenon first studied experimentally is at first reproduced here theoretically. The magnetic field effect is shown to vanish in both limits of high and low solvent diffusivity reaching a maximum in between. It is also very sensitive to the solvent dielectric constant and to the exciplex and radical-ion pair conversion rates

  6. Diffusion affected magnetic field effect in exciplex fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Burshtein, Anatoly I. [Weizmann Institute of Science, Rehovot 76100 (Israel); Ivanov, Anatoly I., E-mail: Anatoly.Ivanov@volsu.ru [Volgograd State University, University Avenue, 100, Volgograd 400062 (Russian Federation)

    2014-07-14

    The fluorescence of the exciplex, {sup 1}[D{sup +δ}A{sup −δ}], formed at contact of photoexcited acceptor {sup 1}A{sup *} with an electron donor {sup 1}D, is known to be very sensitive to an external magnetic field, reducing the spin conversion efficiency in the resulting geminate radical ion pair, {sup 1,3}[D{sup +}…A{sup −}]. The relative increase of the exciplex fluorescence in the highest magnetic field compared to the lowest one, known as the magnetic field effect, crucially depends on the viscosity of the solvent. This phenomenon first studied experimentally is at first reproduced here theoretically. The magnetic field effect is shown to vanish in both limits of high and low solvent diffusivity reaching a maximum in between. It is also very sensitive to the solvent dielectric constant and to the exciplex and radical-ion pair conversion rates.

  7. Diffusion affected magnetic field effect in exciplex fluorescence

    Science.gov (United States)

    Burshtein, Anatoly I.; Ivanov, Anatoly I.

    2014-07-01

    The fluorescence of the exciplex, 1[D+δA-δ], formed at contact of photoexcited acceptor 1A* with an electron donor 1D, is known to be very sensitive to an external magnetic field, reducing the spin conversion efficiency in the resulting geminate radical ion pair, 1, 3[D+…A-]. The relative increase of the exciplex fluorescence in the highest magnetic field compared to the lowest one, known as the magnetic field effect, crucially depends on the viscosity of the solvent. This phenomenon first studied experimentally is at first reproduced here theoretically. The magnetic field effect is shown to vanish in both limits of high and low solvent diffusivity reaching a maximum in between. It is also very sensitive to the solvent dielectric constant and to the exciplex and radical-ion pair conversion rates.

  8. Retinal protective effects of topically administered agmatine on ischemic ocular injury caused by transient occlusion of the ophthalmic artery

    Directory of Open Access Journals (Sweden)

    S. Hong

    2012-03-01

    Full Text Available Agmatine, an endogenous polyamine and putative neuromodulator, is known to have neuroprotective effects on various neurons in the central nervous system. We determined whether or not topically administered agmatine could reduce ischemic retinal injury. Transient ocular ischemia was achieved by intraluminal occlusion of the middle cerebral artery of ddY mice (30-35 g for 2 h, which is known to also induce occlusion of the ophthalmic artery. In the agmatine group (N = 6, a 1.0 mM agmatine-containing ophthalmic solution was administered four times daily for 2 weeks before occlusion. In the control group (N = 6, a 0.1% hyaluronic acid ophthalmic solution was instilled at the same times. At 22 h after reperfusion, the eyeballs were enucleated and the retinal sections were stained by terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL. Transient ocular ischemia induced apoptosis of retinal cells in the entire retinal layer, and topically administered agmatine can significantly reduce this ischemic retinal injury. The proportion of apoptotic cells was definitely decreased (P < 0.001; Kruskal-Wallis test. Overall, we determined that topical agmatine application effectively decreases retinal damage in an in vivo ocular ischemic injury model. This implies that agmatine is a good candidate as a direct neuroprotective agent for eyes with ocular ischemic diseases.

  9. Retinal protective effects of topically administered agmatine on ischemic ocular injury caused by transient occlusion of the ophthalmic artery

    Science.gov (United States)

    Hong, S.; Hara, H.; Shimazawa, M.; Hyakkoku, K.; Kim, C.Y.; Seong, G.J.

    2012-01-01

    Agmatine, an endogenous polyamine and putative neuromodulator, is known to have neuroprotective effects on various neurons in the central nervous system. We determined whether or not topically administered agmatine could reduce ischemic retinal injury. Transient ocular ischemia was achieved by intraluminal occlusion of the middle cerebral artery of ddY mice (30-35 g) for 2 h, which is known to also induce occlusion of the ophthalmic artery. In the agmatine group (N = 6), a 1.0 mM agmatine-containing ophthalmic solution was administered four times daily for 2 weeks before occlusion. In the control group (N = 6), a 0.1% hyaluronic acid ophthalmic solution was instilled at the same times. At 22 h after reperfusion, the eyeballs were enucleated and the retinal sections were stained by terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL). Transient ocular ischemia induced apoptosis of retinal cells in the entire retinal layer, and topically administered agmatine can significantly reduce this ischemic retinal injury. The proportion of apoptotic cells was definitely decreased (P agmatine application effectively decreases retinal damage in an in vivo ocular ischemic injury model. This implies that agmatine is a good candidate as a direct neuroprotective agent for eyes with ocular ischemic diseases. PMID:22331138

  10. Transient competitive complexation in biological kinetic isotope fractionation explains nonsteady isotopic effects: Theory and application to denitrification in soils

    Science.gov (United States)

    Maggi, Federico; Riley, William J.

    2009-12-01

    The theoretical formulation of biological kinetic isotope fractionation often assumes first-order or Michaelis-Menten kinetics, the latter solved under the quasi-steady state assumption. Both formulations lead to a constant isotope fractionation factor, therefore they may return incorrect estimations of isotopic effects and misleading interpretations of isotopic signatures when fractionation is not a steady process. We have analyzed the isotopic signature of denitrification in biogeochemical soil systems by Menyailo and Hungate (2006) in which high and variable 15N-N2O enrichment during N2O production and inverse isotope fractionation during N2O consumption could not be explained with first-order kinetics and the Rayleigh equation, or with Michaelis-Menten kinetics. When Michaelis-Menten kinetics were coupled to Monod kinetics to describe biomass and enzyme dynamics, and the quasi-steady state assumption was relaxed, transient Michaelis-Menten-Monod kinetics accurately reproduced the observed concentrations, and variable and inverse isotope fractionations. These results imply a substantial revision in modeling isotopic effects, suggesting that steady state kinetics such as first-order, Rayleigh, and classic Michaelis-Menten kinetics should be superseded by transient kinetics in conjunction with biomass and enzyme dynamics.

  11. Transient Beneficial Effects of Excitatory Theta Burst Stimulation in a Patient with Phonological Agraphia after Left Supramarginal Gyrus Infarction

    Science.gov (United States)

    Nardone, Raffaele; De Blasi, Pierpaolo; Zuccoli, Giulio; Tezzon, Frediano; Golaszewski, Stefan; Trinka, Eugen

    2012-01-01

    We report a patient showing isolated phonological agraphia after an ischemic stroke involving the left supramarginal gyrus (SMG). In this patient, we investigated the effects of focal repetitive transcranial magnetic stimulation (rTMS) given as theta burst stimulation (TBS) over the left SMG, corresponding to the Brodmann area (BA) 40. The patient…

  12. Effects of multiple resistive shells and transient electromagnetic torque on the dynamics of mode locking in reversed field pinch plasmas

    International Nuclear Information System (INIS)

    Guo, S.C.; Chu, M.S.

    2002-01-01

    The effects of multiple resistive shells and transient electromagnetic torque on the dynamics of mode locking in the reversed field pinch (RFP) plasmas are studied. Most RFP machines are equipped with one or more metal shells outside of the vacuum vessel. These shells have finite resistivities. The eddy currents induced in each of the shells contribute to the braking electromagnetic (EM) torque which slows down the plasma rotation. In this work we study the electromagnetic torque acting on the plasma (tearing) modes produced by a system of resistive shells. These shells may consist of several nested thin shells or several thin shells enclosed within a thick shell. The dynamics of the plasma mode is investigated by balancing the EM torque from the resistive shells with the plasma viscous torque. Both the steady state theory and the time-dependent theory are developed. The steady state theory is shown to provide an accurate account of the resultant EM torque if (dω/dt)ω -2 <<1 and the time scale of interest is much longer than the response (L/R) time of the shell. Otherwise, the transient theory should be adopted. As applications, the steady state theory is used to evaluate the changes of the EM torque response from the resistive shells in two variants of two RFP machines: (1) modification from Reversed Field Experiment (RFX) [Gnesotto et al., Fusion Eng. Des. 25, 335 (1995)] to the modified RFX: both of them are equipped with one thin shell plus one thick shell; (2) modification from Extrap T2 to Extrap T2R [Brunsell et al., Plasma Phys. Controlled Fusion 43, 1457 (2001)]: both of them are equipped with two thin shells. The transient theory has been applied numerically to study the time evolution of the EM torque during the unlocking of a locked tearing mode in the modified RFX

  13. Effects of 3D magnetic perturbations on toroidal plasmas

    International Nuclear Information System (INIS)

    Callen, J.D.

    2011-01-01

    Small three-dimensional (3D) magnetic field perturbations have many interesting and possibly useful effects on tokamak and quasi-symmetric stellarator plasmas. Plasma transport equations that include these effects, most notably on diamagnetic-level toroidal plasma flows, have recently been developed. The 3D field perturbations and their plasma effects can be classified according to their toroidal mode number n: low n (say 1-5) resonant (with field line pitch, q = m/n) and non-resonant fields, medium n (∼20, due to toroidal field ripple) and high n (due to microturbulence). Low n non-resonant fields induce a neoclassical toroidal viscosity (NTV) that damps toroidal rotation throughout the plasma towards an offset rotation in the counter-current direction. Recent tokamak experiments have generally confirmed and exploited these predictions by applying external low n non-resonant magnetic perturbations. Medium n toroidal field ripple produces similar effects plus possible ripple-trapping NTV effects and ion direct losses in the edge. A low n (e.g. n = 1) resonant field is mostly shielded by the toroidally rotating plasma at and inside the resonant (rational) surface. If it is large enough it can stop plasma rotation at the rational surface, facilitate magnetic reconnection there and lead to a growing stationary magnetic island (locked mode), which often causes a plasma disruption. Externally applied 3D magnetic perturbations usually have many components. In the plasma their lowest n (e.g. n = 1) externally resonant components can be amplified by kink-type plasma responses, particularly at high β. Low n plasma instabilities (e.g. resistive wall modes, neoclassical tearing modes) cause additional 3D magnetic perturbations in tokamak plasmas. Tearing modes in their nonlinear (Rutherford) regime bifurcate the topology and form magnetic islands. Finally, multiple resonant magnetic perturbations (RMPs) can, if not shielded by plasma rotation effects, cause local magnetic

  14. Three-dimensional configuration and damping effect of flare coronal transients

    International Nuclear Information System (INIS)

    Ivanov, K.G.; Kharshiladze, A.F.

    1989-01-01

    Inverse problem of searching for three - dimensional configuration of coronal mass outburst (CMO) in the class of flattened spheroids was solved on the basis of solving primal problem of projecting CMO of the given configuration on celestial plane, using experimental data of white light coronograph. It was obtained that CMO, as interplanetary shock waves, were oblate with ∼ 1.25 ratio of axes to the plane of great circle, passing through the flare, parallel to magnetic axis of the nearest bipolar group

  15. Magnetic Nanoparticles: Surface Effects and Properties Related to Biomedicine Applications

    OpenAIRE

    Issa, Bashar; Obaidat, Ihab M.; Albiss, Borhan A.; Haik, Yousef

    2013-01-01

    Due to finite size effects, such as the high surface-to-volume ratio and different crystal structures, magnetic nanoparticles are found to exhibit interesting and considerably different magnetic properties than those found in their corresponding bulk materials. These nanoparticles can be synthesized in several ways (e.g., chemical and physical) with controllable sizes enabling their comparison to biological organisms from cells (10–100 μm), viruses, genes, down to proteins (3–50 nm). The opti...

  16. EPR spectroscopy of MRI-related Gd(III) complexes: simultaneous analysis of multiple frequency and temperature spectra, including static and transient crystal field effects.

    Science.gov (United States)

    Rast, S; Borel, A; Helm, L; Belorizky, E; Fries, P H; Merbach, A E

    2001-03-21

    For the first time, a very general theoretical method is proposed to interpret the full electron paramagnetic resonance (EPR) spectra at multiple temperatures and frequencies in the important case of S-state metal ions complexed in liquid solution. This method is illustrated by a careful analysis of the measured spectra of two Gd3+ (S = 7/2) complexes. It is shown that the electronic relaxation mechanisms at the origin of the EPR line shape arise from the combined effects of the modulation of the static crystal field by the random Brownian rotation of the complex and of the transient zero-field splitting. A detailed study of the static crystal field mechanism shows that, contrarily to the usual global models involving only second-order terms, the fourth and sixth order terms can play a non-negligible role. The obtained parameters are well interpreted in the framework of the physics of the various underlying relaxation processes. A better understanding of these mechanisms is highly valuable since they partly control the efficiency of paramagnetic metal ions in contrast agents for medical magnetic resonance imaging (MRI).

  17. Estimating blood and brain concentrations and blood-to-brain influx by magnetic resonance imaging with step-down infusion of Gd-DTPA in focal transient cerebral ischemia and confirmation by quantitative autoradiography with Gd-[14C]DTPA

    OpenAIRE

    Knight, Robert A; Karki, Kishor; Ewing, James R; Divine, George W; Fenstermacher, Joseph D; Patlak, Clifford S; Nagaraja, Tavarekere N

    2009-01-01

    An intravenous step-down infusion procedure that maintained a constant gadolinium-diethylene-triaminepentaacetic acid (Gd-DTPA) blood concentration and magnetic resonance imaging (MRI) were used to localize and quantify the blood–brain barrier (BBB) opening in a rat model of transient cerebral ischemia (n = 7). Blood-to-brain influx rate constant (Ki) values of Gd-DTPA from such regions were estimated using MRI–Patlak plots and compared with the Ki values of Gd-[14C]DTPA, determined minutes l...

  18. Effects of the magnetic field variation on the spin wave interference in a magnetic cross junction

    Science.gov (United States)

    Balynskiy, M.; Chiang, H.; Kozhevnikov, A.; Dudko, G.; Filimonov, Y.; Balandin, A. A.; Khitun, A.

    2018-05-01

    This article reports results of the investigation of the effect of the external magnetic field variation on the spin wave interference in a magnetic cross junction. The experiments were performed using a micrometer scale Y3Fe5O12 cross structure with a set of micro-antennas fabricated on the edges of the cross arms. Two of the antennas were used for the spin wave excitation while a third antenna was used for detecting the inductive voltage produced by the interfering spin waves. It was found that a small variation of the bias magnetic field may result in a significant change of the output inductive voltage. The effect is most prominent under the destructive interference condition. The maximum response exceeds 30 dB per 0.1 Oe at room temperature. It takes a relatively small bias magnetic field variation of about 1 Oe to drive the system from the destructive to the constructive interference conditions. The switching is accompanied by a significant, up to 50 dB, change in the output voltage. The obtained results demonstrate a feasibility of the efficient spin wave interference control by an external magnetic field, which may be utilized for engineering novel type of magnetometers and magnonic logic devices.

  19. Effective Induction Heating around Strongly Magnetized Stars

    Science.gov (United States)

    Kislyakova, K. G.; Fossati, L.; Johnstone, C. P.; Noack, L.; Lüftinger, T.; Zaitsev, V. V.; Lammer, H.

    2018-05-01

    Planets that are embedded in the changing magnetic fields of their host stars can experience significant induction heating in their interiors caused by the planet’s orbital motion. For induction heating to be substantial, the planetary orbit has to be inclined with respect to the stellar rotation and dipole axes. Using WX UMa, for which the rotation and magnetic axes are aligned, as an example, we show that for close-in planets on inclined orbits, induction heating can be stronger than the tidal heating occurring inside Jupiter’s satellite Io; namely, it can generate a surface heat flux exceeding 2 W m‑2. An internal heating source of such magnitude can lead to extreme volcanic activity on the planet’s surface, possibly also to internal local magma oceans, and to the formation of a plasma torus around the star aligned with the planetary orbit. A strongly volcanically active planet would eject into space mostly SO2, which would then dissociate into oxygen and sulphur atoms. Young planets would also eject CO2. Oxygen would therefore be the major component of the torus. If the O I column density of the torus exceeds ≈1012 cm‑2, the torus could be revealed by detecting absorption signatures at the position of the strong far-ultraviolet O I triplet at about 1304 Å. We estimate that this condition is satisfied if the O I atoms in the torus escape the system at a velocity smaller than 1–10 km s‑1. These estimates are valid also for a tidally heated planet.

  20. Effect of transient occlusal loading on the threshold of tooth tactile sensation perception for tapping like the impulsive stimulation.

    Science.gov (United States)

    Morimoto, Yuta; Oki, Kazuhiro; Iida, Sachiyo; Shirahige, Chieko; Maeda, Naoto; Kawakami, Shigehisa; Matsunaga, Tadashi; Minagi, Shogo

    2013-07-01

    The objectives of this study were (1) to establish a reliable method for detecting the force threshold of the tooth tactile sensation while avoiding experimenter bias and (2) to examine the effect of occlusal force loading on the threshold for impulsive force stimulation in subjects with normal dentition. Twenty volunteers participated in this study (10 males and 10 females; mean age, 26.6 ± 2.9 years). To simulate the bite force during occlusal tapping, a force-loading device was designed to exert impulsive force to the occlusal surface in the direction parallel to the tooth axis. The impulsive force detection threshold of the periodontal sensation was measured before and after loading 98 N of occlusal force on the left upper first molar for 1 min. Transient mechanical loading of the upper first molar caused an increase in the absolute threshold for impulsive force. This increase did not vanish immediately, and the increment of the threshold was maintained during the remainder of the experiment. A computer-controlled method for the evaluation of tooth tactile sensation using impulsive stimulation was established. Transient occlusal force loading parallel to the tooth axis increases the threshold of periodontal sensation for mechanical impulsive stimulation.

  1. The Effect of Acute Otitis Media on Transient Otoacoustic Emissions A Clinical Guide to Successful Treatment Course

    Directory of Open Access Journals (Sweden)

    A. Bayat

    Full Text Available Introduction & Objective: Acute otitis media (AOM is the most common causes of acquired hearing loss in children with increasing incidence. In young children the diagnosis is restricted to otoscopy and tympanometry whereas evaluation of the auditory function is impossible due to noncompliance during pure tone audiometry. For this purpose, measurement of otoacoustic emissions, especially transient evoked ones (TEOAEs, can be applied. The aim of this study was to evaluate the effect of AOM on TEOAEs in young children before and after treatment course.Material & Methods: In an analytic, cross-sectional design, 42 young children with AOM, both sexes, aged 2 to 4.5 years were evaluated through tympanometry and transient otoacoustic emissions (TEOAEs. TEOAEs signal to noise ratio (SNR and reproducibility of AOM patients were compared before, two weeks and six weeks after the treatment course. Then AOM responses were compared with an age-matched control group. The results were analyzed using SPSS 16.Results: Our findings revealed that TEOAE parameters in AOM subjects were the most affected on highest frequencies. Significant changes of TEOAE parameters were found 2 weeks after the treatment with further improvement 6 weeks after the treatment course (P 0.05.Conclusion: The results of this study suggest that there was an improvement in TEOAE SNR and band reproducibility in serial TEOAEs measurements. Thus,application of TEOAEs is a beneficial method to follow up medical treatment in young children with AOM. (Sci J Hamadan Univ Med Sci 2011;18(3:17-21

  2. The Effect of Acute Otitis Media on Transient Otoacoustic Emissions A Clinical Guide to Successful Treatment Course

    Directory of Open Access Journals (Sweden)

    Arash Bayat

    2011-09-01

    Full Text Available Introduction & Objective: Acute otitis media (AOM is the most common causes of acquired hearing loss in children with increasing incidence. In young children the diagnosis is restricted to otoscopy and tympanometry whereas evaluation of the auditory function is impossible due to noncompliance during pure tone audiometry. For this purpose, measurement of otoacoustic emissions, especially transient evoked ones (TEOAEs, can be applied. The aim of this study was to evaluate the effect of AOM on TEOAEs in young children before and after treatment course. Material & Methods: In an analytic, cross-sectional design, 42 young children with AOM, both sexes, aged 2 to 4.5 years were evaluated through tympanometry and transient otoacoustic emissions (TEOAEs. TEOAEs signal to noise ratio (SNR and reproducibility of AOM patients were compared before, two weeks and six weeks after the treatment course. Then AOM responses were compared with an age-matched control group. The results were analyzed using SPSS 16. Results: Our findings revealed that TEOAE parameters in AOM subjects were the most affected on highest frequencies. Significant changes of TEOAE parameters were found 2 weeks after the treatment with further improvement 6 weeks after the treatment course (P 0.05. Conclusion: The results of this study suggest that there was an improvement in TEOAE SNR and band reproducibility in serial TEOAEs measurements. Thus,application of TEOAEs is a beneficial method to follow up medical treatment in young children with AOM.

  3. Transient groundwater chemistry near a river: Effects on U(VI) transport in laboratory column experiments

    Science.gov (United States)

    Yin, Jun; Haggerty, Roy; Stoliker, Deborah L.; Kent, Douglas B.; Istok, Jonathan D.; Greskowiak, Janek; Zachara, John M.

    2011-01-01

    In the 300 Area of a U(VI)-contaminated aquifer at Hanford, Washington, USA, inorganic carbon and major cations, which have large impacts on U(VI) transport, change on an hourly and seasonal basis near the Columbia River. Batch and column experiments were conducted to investigate the factors controlling U(VI) adsorption/desorption by changing chemical conditions over time. Low alkalinity and low Ca concentrations (Columbia River water) enhanced adsorption and reduced aqueous concentrations. Conversely, high alkalinity and high Ca concentrations (Hanford groundwater) reduced adsorption and increased aqueous concentrations of U(VI). An equilibrium surface complexation model calibrated using laboratory batch experiments accounted for the decrease in U(VI) adsorption observed with increasing (bi)carbonate concentrations and other aqueous chemical conditions. In the column experiment, alternating pulses of river and groundwater caused swings in aqueous U(VI) concentration. A multispecies multirate surface complexation reactive transport model simulated most of the major U(VI) changes in two column experiments. The modeling results also indicated that U(VI) transport in the studied sediment could be simulated by using a single kinetic rate without loss of accuracy in the simulations. Moreover, the capability of the model to predict U(VI) transport in Hanford groundwater under transient chemical conditions depends significantly on the knowledge of real-time change of local groundwater chemistry.

  4. Analyzing degradation effects of organic light-emitting diodes via transient optical and electrical measurements

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Tobias D., E-mail: Tobias.Schmidt@physik.uni-augsburg.de; Jäger, Lars; Brütting, Wolfgang, E-mail: Wolfgang.Bruetting@physik.uni-augsburg.de [Institute of Physics, University of Augsburg, Augsburg (Germany); Noguchi, Yutaka [Department of Electronics and Bioinformatics, School of Science and Technology, Meiji University, Kawasaki (Japan); Center of Frontier Science, Chiba University, Chiba (Japan); Ishii, Hisao [Center of Frontier Science, Chiba University, Chiba (Japan)

    2015-06-07

    Although the long-term stability of organic light-emitting diodes (OLEDs) under electrical operation made significant progress in recent years, the fundamental underlying mechanisms of the efficiency decrease during operation are not well understood. Hence, we present a comprehensive degradation study of an OLED structure comprising the well-known green phosphorescent emitter Ir(ppy){sub 3}. We use transient methods to analyze both electrical and optical changes during an accelerated aging protocol. Combining the results of displacement current measurements with time-resolved investigation of the excited states lifetimes of the emitter allows for a correlation of electrical (e.g., increase of the driving voltage due to trap formation) and optical (e.g., decrease of light-output) changes induced by degradation. Therewith, it is possible to identify two mechanisms resulting in the drop of the luminance: a decrease of the radiative quantum efficiency of the emitting system due to triplet-polaron-quenching at trapped charge carriers and a modified charge carrier injection and transport, as well as trap-assisted non-radiative recombination resulting in a deterioration of the charge carrier balance of the device.

  5. How clarinettists articulate: The effect of blowing pressure and tonguing on initial and final transients.

    Science.gov (United States)

    Li, Weicong; Almeida, André; Smith, John; Wolfe, Joe

    2016-02-01

    Articulation, including initial and final note transients, is important to tasteful music performance. Clarinettists' tongue-reed contact, the time variation of the blowing pressure P¯mouth, the mouthpiece pressure, the pressure in the instrument bore, and the radiated sound were measured for normal articulation, accents, sforzando, staccato, and for minimal attack, i.e., notes started very softly. All attacks include a phase when the amplitude of the fundamental increases exponentially, with rates r ∼1000 dB s(-1) controlled by varying both the rate of increase in P¯mouth and the timing of tongue release during this increase. Accented and sforzando notes have shorter attacks (r∼1300 dB s(-1)) than normal notes. P¯mouth reaches a higher peak value for accented and sforzando notes, followed by a steady decrease for accented notes or a rapid fall to a lower, nearly steady value for sforzando notes. Staccato notes are usually terminated by tongue contact, producing an exponential decrease in sound pressure with rates similar to those calculated from the bandwidths of the bore resonances: ∼400 dB s(-1). In all other cases, notes are stopped by decreasing P¯mouth. Notes played with different dynamics are qualitatively similar, but louder notes have larger P¯mouth and larger r.

  6. Effects of transient high temperature treatment on the intestinal flora of the silkworm Bombyx mori.

    Science.gov (United States)

    Sun, Zhenli; Kumar, Dhiraj; Cao, Guangli; Zhu, Liyuan; Liu, Bo; Zhu, Min; Liang, Zi; Kuang, Sulan; Chen, Fei; Feng, Yongjie; Hu, Xiaolong; Xue, Renyu; Gong, Chengliang

    2017-06-13

    The silkworm Bombyx mori is a poikilotherm and is therefore sensitive to various climatic conditions. The influence of temperature on the intestinal flora and the relationship between the intestinal flora and gene expression in the silkworm remain unknown. In the present study, changes of the intestinal flora at 48, 96 and 144 h following transient high temperature treatment (THTT) of 37 °C for 8 h were investigated. According to principal component analysis, the abundances of Enterococcus and Staphylococcus showed a negative correlation with other dominant genera. After THTT, the gene expression levels of spatzle-1 and dicer-2 were increased and decreased, respectively, which suggested that the Toll and RNAi pathways were activated and suppressed, respectively. The species-gene expression matrix confirmed that the spatzle-1 and dicer-2 gene expression levels were negatively and positively correlated, respectively, with the abundance of Enterococcus and Staphylococcus in the control. The abundance of Variovorax post-THTT was positively correlated with the spatzle-1 gene expression level, whereas the community richness of Enterococcus was negatively correlated with the spatzle-1 gene expression level and positively correlated with the dicer-2. The results of the present investigation provide new evidence for understanding the relationships among THTT, intestinal flora and host gene expression.

  7. Numerical Analysis of the Effect of T-tubule Location on Calcium Transient in Ventricular Myocytes

    Science.gov (United States)

    George, Uduak Z.; Wang, Jun; Yu, Zeyun

    2013-01-01

    Intracellular calcium (Ca2+) signaling in cardiac myocytes is vital for proper functioning of the heart. Understanding the intracellular Ca2+ dynamics would give an insight into the functions of normal and diseased hearts. In the current study, spatiotemporal Ca2+ dynamics is investigated in ventricular myocytes by considering Ca2+ release and re-uptake via sarcolemma and transverse tubules (T-tubules), Ca2+ diffusion and buffering in the cytosol, and the blockade of Ca2+ activities associated with the sarcoplasmic reticulum. This study is carried out using a three dimensional (3D) geometric model of a branch of T-tubule extracted from the electron microscopy (EM) images of a partial ventricular myocyte. Mathematical modeling is done by using a system of partial differential equations involving Ca2+ , buffers, and membrane channels. Numerical simulation results suggest that a lack of T-tubule structure at the vicinity of the cell surface could increase the peak time of Ca2+ concentration in myocytes. The results also show that T-tubules and mobile buffers play an important role in the regulation of Ca2+ transient in ventricular myocytes. PMID:24212025

  8. Full particle orbit effects in regular and stochastic magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Shun, E-mail: shun.ogawa@cpt.univ-mrs.fr [Aix Marseille Univ., Univ. Toulon, CNRS, CPT, Marseille (France); CEA, IRFM, F-13108 St. Paul-lez-Durance Cedex (France); Cambon, Benjamin; Leoncini, Xavier; Vittot, Michel [Aix Marseille Univ., Univ. Toulon, CNRS, CPT, Marseille (France); Castillo-Negrete, Diego del [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831-6169 (United States); Dif-Pradalier, Guilhem; Garbet, Xavier [CEA, IRFM, F-13108 St. Paul-lez-Durance Cedex (France)

    2016-07-15

    We present a numerical study of charged particle motion in a time-independent magnetic field in cylindrical geometry. The magnetic field model consists of an unperturbed reversed-shear (non-monotonic q-profile) helical part and a perturbation consisting of a superposition of modes. Contrary to most of the previous studies, the particle trajectories are computed by directly solving the full Lorentz force equations of motion in a six-dimensional phase space using a sixth-order, implicit, symplectic Gauss-Legendre method. The level of stochasticity in the particle orbits is diagnosed using averaged, effective Poincare sections. It is shown that when only one mode is present, the particle orbits can be stochastic even though the magnetic field line orbits are not stochastic (i.e., fully integrable). The lack of integrability of the particle orbits in this case is related to separatrix crossing and the breakdown of the global conservation of the magnetic moment. Some perturbation consisting of two modes creates resonance overlapping, leading to Hamiltonian chaos in magnetic field lines. Then, the particle orbits exhibit a nontrivial dynamics depending on their energy and pitch angle. It is shown that the regions where the particle motion is stochastic decrease as the energy increases. The non-monotonicity of the q-profile implies the existence of magnetic ITBs (internal transport barriers) which correspond to shearless flux surfaces located in the vicinity of the q-profile minimum. It is shown that depending on the energy, these magnetic ITBs might or might not confine particles. That is, magnetic ITBs act as an energy-dependent particle confinement filter. Magnetic field lines in reversed-shear configurations exhibit topological bifurcations (from homoclinic to heteroclinic) due to separatrix reconnection. We show that a similar but more complex scenario appears in the case of particle orbits that depend in a non-trivial way on the energy and pitch angle of the

  9. Solution-processed single-walled carbon nanotube field effect transistors and bootstrapped inverters for disintegratable, transient electronics

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Sung Hun, E-mail: harin74@gmail.com, E-mail: jhl@snu.ac.kr, E-mail: jrogers@illinois.edu; Shin, Jongmin; Cho, In-Tak; Lee, Jong-Ho, E-mail: harin74@gmail.com, E-mail: jhl@snu.ac.kr, E-mail: jrogers@illinois.edu [Department of Electrical and Computer Engineering and Inter-University Semiconductor Research Center, Seoul National University, Seoul 151-742 (Korea, Republic of); Han, Sang Youn [Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Display R and D Center, Samsung Display Co., Yongin-city, Gyeongki-do 446–711 (Korea, Republic of); Lee, Dong Joon; Lee, Chi Hwan; Rogers, John A., E-mail: harin74@gmail.com, E-mail: jhl@snu.ac.kr, E-mail: jrogers@illinois.edu [Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States)

    2014-07-07

    This paper presents materials, device designs, and physical/electrical characteristics of a form of nanotube electronics that is physically transient, in the sense that all constituent elements dissolve and/or disperse upon immersion into water. Studies of contact effects illustrate the ability to use water soluble metals such as magnesium for source/drain contacts in nanotube based field effect transistors. High mobilities and on/off ratios in transistors that use molybdenum, silicon nitride, and silicon oxide enable full swing characteristics for inverters at low voltages (∼5 V) and with high gains (∼30). Dissolution/disintegration tests of such systems on water soluble sheets of polyvinyl alcohol demonstrate physical transience within 30 min.

  10. The effect of code user and boundary conditions on RELAP calculations of MTR research reactor transient scenarios

    Directory of Open Access Journals (Sweden)

    Khedr Ahmed

    2005-01-01

    Full Text Available The safety evaluation of nuclear power and re search reactors is a very important step before their construction and during their operation. This evaluation based on the best estimate calculations requires qualified codes qualified users, and qualified nodalizations. The effect of code users on the RELAP5 results during the analysis of loss of flow transient in MTR research reactors is presented in this pa per. To clarify this effect, two nodalizations for research reactor different in the simulation of the open water surface boundary conditions of the reactor pool have been used. Very different results are obtained with few choices for code users. The core natural circulation flow with the be ginning of core boiling doesn't stop but in creases. The in creasing in the natural circulation flow shifts out the boiling from the core and the clad temperature decreases be low the local saturation temperature.

  11. Hall Effect and transient surface photovoltage (SPV study of Cu3BiS3 thin films

    Directory of Open Access Journals (Sweden)

    F. Mesa

    2014-03-01

    Full Text Available Here, we present the electrical properties of the compound Cu3BiS3 deposited by co-evaporation. This new compound may have the properties necessary to be used as an absorbent layer in solar cells. The samples were characterized by Hall effect and transient surface photovoltage (SPV measurements. Using Hall effect measurements, we found that the concentration of n charge carriers is in the order of 1016 cm-3 irrespective of the Cu/Bi mass ratio. We also found that the mobility of this compound (μ in the order of 4 cm2 V-1s-1 varies according to the transport mechanisms that govern it and are dependent on temperature. Based on the SPV, we found a high density of surface defects, which can be passivated by superimposing a buffer layer over the Cu3BiS3 compound.

  12. Solution-processed single-walled carbon nanotube field effect transistors and bootstrapped inverters for disintegratable, transient electronics

    International Nuclear Information System (INIS)

    Jin, Sung Hun; Shin, Jongmin; Cho, In-Tak; Lee, Jong-Ho; Han, Sang Youn; Lee, Dong Joon; Lee, Chi Hwan; Rogers, John A.

    2014-01-01

    This paper presents materials, device designs, and physical/electrical characteristics of a form of nanotube electronics that is physically transient, in the sense that all constituent elements dissolve and/or disperse upon immersion into water. Studies of contact effects illustrate the ability to use water soluble metals such as magnesium for source/drain contacts in nanotube based field effect transistors. High mobilities and on/off ratios in transistors that use molybdenum, silicon nitride, and silicon oxide enable full swing characteristics for inverters at low voltages (∼5 V) and with high gains (∼30). Dissolution/disintegration tests of such systems on water soluble sheets of polyvinyl alcohol demonstrate physical transience within 30 min.

  13. Magnetic nanoparticles: surface effects and properties related to biomedicine applications.

    Science.gov (United States)

    Issa, Bashar; Obaidat, Ihab M; Albiss, Borhan A; Haik, Yousef

    2013-10-25

    Due to finite size effects, such as the high surface-to-volume ratio and different crystal structures, magnetic nanoparticles are found to exhibit interesting and considerably different magnetic properties than those found in their corresponding bulk materials. These nanoparticles can be synthesized in several ways (e.g., chemical and physical) with controllable sizes enabling their comparison to biological organisms from cells (10-100 μm), viruses, genes, down to proteins (3-50 nm). The optimization of the nanoparticles' size, size distribution, agglomeration, coating, and shapes along with their unique magnetic properties prompted the application of nanoparticles of this type in diverse fields. Biomedicine is one of these fields where intensive research is currently being conducted. In this review, we will discuss the magnetic properties of nanoparticles which are directly related to their applications in biomedicine. We will focus mainly on surface effects and ferrite nanoparticles, and on one diagnostic application of magnetic nanoparticles as magnetic resonance imaging contrast agents.

  14. Effect of soft underlayer magnetic anisotropy on perpendicular recording process

    International Nuclear Information System (INIS)

    Lim, C.K.; Kim, E.S.; Yoon, S.Y.; Kong, S.H.; Lee, H.S.; Oh, H.S.; Kim, Y.S.

    2007-01-01

    The presence of the soft magnetic underlayer (SUL) in perpendicular magnetic recording (PMR) media is essential for the application. It is commonly understood that the SUL provides the return flux path and enhances the writing field by enhancing the recording field from the write pole. However, SUL increases the magnetic noise during the read back process due to magnetic domain walls in the SUL. Hence, it is common to grow SUL with large uniaxial or unidirectional magnetic anisotropy field (H k ) to reduce domain wall noise. In this paper, we explore the effect of increasing SUL H k on the recording process. We studied this effect by using the finite element micromagnetic simulation. Our simulation results show that the contribution of SUL to the writing field amplitude is reduced with increasing H k . This reduction in magnetic field from high H k SUL actually improves the recording performance due to the better field gradient at SUL. The simulation results are qualitatively consistent with the actual experimental data obtained from the Guzik measurement

  15. Effect of substrate rotation on domain structure and magnetic relaxation in magnetic antidot lattice arrays

    International Nuclear Information System (INIS)

    Mallick, Sougata; Mallik, Srijani; Bedanta, Subhankar

    2015-01-01

    Microdimensional triangular magnetic antidot lattice arrays were prepared by varying the speed of substrate rotation. The pre-deposition patterning has been performed using photolithography technique followed by a post-deposition lift-off. Surface morphology taken by atomic force microscopy depicted that the growth mechanism of the grains changes from chain like formation to island structures due to the substrate rotation. Study of magnetization reversal via magneto optic Kerr effect based microscopy revealed reduction of uniaxial anisotropy and increase in domain size with substrate rotation. The relaxation measured under constant magnetic field becomes faster with rotation of the substrate during deposition. The nature of relaxation for the non-rotating sample can be described by a double exponential decay. However, the relaxation for the sample with substrate rotation is well described either by a double exponential or a Fatuzzo-Labrune like single exponential decay, which increases in applied field

  16. Analysis of ringing effects due to magnetic core materials in pulsed nuclear magnetic resonance circuits

    International Nuclear Information System (INIS)

    Prabhu Gaunkar, N.; Bouda, N. R. Y.; Nlebedim, I. C.; Hadimani, R. L.; Mina, M.; Jiles, D. C.; Bulu, I.; Ganesan, K.; Song, Y. Q.

    2015-01-01

    This work presents investigations and detailed analysis of ringing in a non-resonant pulsed nuclear magnetic resonance (NMR) circuit. Ringing is a commonly observed phenomenon in high power switching circuits. The oscillations described as ringing impede measurements in pulsed NMR systems. It is therefore desirable that those oscillations decay fast. It is often assumed that one of the causes behind ringing is the role of the magnetic core used in the antenna (acting as an inductive load). We will demonstrate that an LRC subcircuit is also set-up due to the inductive load and needs to be considered due to its parasitic effects. It is observed that the parasitics associated with the inductive load become important at certain frequencies. The output response can be related to the response of an under-damped circuit and to the magnetic core material. This research work demonstrates and discusses ways of controlling ringing by considering interrelationships between different contributing factors

  17. Effect of thermodynamic fluctuations of magnetization on the bound magnetic polaron state in ferromagnetic semiconductors

    International Nuclear Information System (INIS)

    Bednarski, Henryk; Spałek, Józef

    2014-01-01

    We extend the theory of the bound magnetic polaron (BMP) in diluted paramagnetic semiconductors to the situation with a ferromagnetic phase transition. This is achieved by including the classical Gaussian fluctuations of magnetization from the quartic (non-Gaussian) term in the effective Ginzburg–Landau Hamiltonian for the spins. Within this approach, we find a ferromagnetically ordered state within the BMP in the temperature range well above the Curie temperature for the host magnetic semiconductor. Numerical results are compared directly with the recently available experimental data for the ferromagnetic semiconductor GdN. The agreement is excellent, given the simplicity of our model, and is because the polaron size (≃1.4 nm) encompasses a relatively large but finite number (N≈400) of quasiclassical spins S=7/2 coming from Gd 3+ ions. The presence of BMP invalidates the notion of critical temperature and thus makes the incorporation of classical Gaussian fluctuations sufficient to realistically describe the situation. (paper)

  18. Analysis of ringing effects due to magnetic core materials in pulsed nuclear magnetic resonance circuits

    Energy Technology Data Exchange (ETDEWEB)

    Prabhu Gaunkar, N., E-mail: neelampg@iastate.edu; Bouda, N. R. Y.; Nlebedim, I. C.; Hadimani, R. L.; Mina, M.; Jiles, D. C. [Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011 (United States); Bulu, I.; Ganesan, K.; Song, Y. Q. [Schlumberger-Doll Research, Cambridge, Massachusetts 02139 (United States)

    2015-05-07

    This work presents investigations and detailed analysis of ringing in a non-resonant pulsed nuclear magnetic resonance (NMR) circuit. Ringing is a commonly observed phenomenon in high power switching circuits. The oscillations described as ringing impede measurements in pulsed NMR systems. It is therefore desirable that those oscillations decay fast. It is often assumed that one of the causes behind ringing is the role of the magnetic core used in the antenna (acting as an inductive load). We will demonstrate that an LRC subcircuit is also set-up due to the inductive load and needs to be considered due to its parasitic effects. It is observed that the parasitics associated with the inductive load become important at certain frequencies. The output response can be related to the response of an under-damped circuit and to the magnetic core material. This research work demonstrates and discusses ways of controlling ringing by considering interrelationships between different contributing factors.

  19. Annealing effects on magnetic properties of silicone-coated iron-based soft magnetic composites

    International Nuclear Information System (INIS)

    Wu Shen; Sun Aizhi; Zhai Fuqiang; Wang Jin; Zhang Qian; Xu Wenhuan; Logan, Philip; Volinsky, Alex A.

    2012-01-01

    This paper focuses on novel iron-based soft magnetic composites synthesis utilizing high thermal stability silicone resin to coat iron powder. The effect of an annealing treatment on the magnetic properties of synthesized magnets was investigated. The coated silicone insulating layer was characterized by scanning electron microscopy and energy dispersive X-ray spectroscopy. Silicone uniformly coated the powder surface, resulting in a reduction of the imaginary part of the permeability, thereby increasing the electrical resistivity and the operating frequency of the synthesized magnets. The annealing treatment increased the initial permeability, the maximum permeability, and the magnetic induction, and decreased the coercivity. Annealing at 580 °C increased the maximum permeability by 72.5%. The result of annealing at 580 °C shows that the ferromagnetic resonance frequency increased from 2 kHz for conventional epoxy resin coated samples to 80 kHz for the silicone resin insulated composites. - Highlights: ► Silicone uniformly coated the powder, increased the operating frequency of SMCs. ► The annealing treatment increased the DC properties of SMCs. ► Annealing at 580 °C increased the maximum permeability by 72.5%. ► Compared with epoxy coated, the SMCs had higher resistivity annealing at 580 °C.

  20. Effects of sample size on the second magnetization peak in ...

    Indian Academy of Sciences (India)

    the sample size decreases – a result that could be interpreted as a size effect in the order– disorder vortex matter phase transition. However, local magnetic measurements trace this effect to metastable disordered vortex states, revealing the same order–disorder transition induction in samples of different size. Keywords.

  1. Measurement of the magnetic moment of the 2$^{+}$ state in neutron-rich radioactive $^{72,74}$Zn using the transient field technique in inverse kinematics

    CERN Multimedia

    Kruecken, R; Speidel, K; Voulot, D; Neyens, G; Gernhaeuser, R A; Fraile prieto, L M; Leske, J

    We propose to measure the sign and magnitude of the g-factors of the first 2$^{+}$ states in radioactive neutron-rich $^{72,74}$Zn applying the transient field (TF) technique in inverse kinematics. The result of this experiment will allow to probe the $\

  2. Magnetic quantum ratchet effect in Si-MOSFETs

    International Nuclear Information System (INIS)

    Ganichev, S D; Karch, J; Kamann, J; Tarasenko, S A; Kvon, Z D

    2014-01-01

    We report on the observation of magnetic quantum ratchet effect in metal-oxide-semiconductor field-effect-transistors on silicon surface (Si-MOSFETs). We show that the excitation of an unbiased transistor by ac electric field of terahertz radiation at normal incidence leads to a direct electric current between the source and drain contacts if the transistor is subjected to an in-plane magnetic field. The current rises linearly with the magnetic field strength and quadratically with the ac electric field amplitude. It depends on the polarization state of the ac field and can be induced by both linearly and circularly polarized radiation. We present the quasi-classical and quantum theories of the observed effect and show that the current originates from the Lorentz force acting upon carriers in asymmetric inversion channels of the transistors. (paper)

  3. Shear zone nucleation and deformation transient: effect of heterogeneities and loading conditions in experimentally deformed calcite

    Science.gov (United States)

    Morales, L. F. G.; Rybacki, E.; Dresen, G. H.; Kilian, R.

    2015-12-01

    In the Earth's middle to lower crust, strain is frequently localized along ductile shear zones, which commonly nucleate at structural and material heterogeneities. To investigate shear zone nucleation and development due to heterogeneities, we performed constant strain-rate (CSR) and constant stress (CS) simple shear (torsion) deformation experiments on Carrara marble samples containing weak (limestone) inclusions. The experiments were conducted in a Paterson-type gas deformation apparatus at 900 °C temperature and 400 MPa confining pressure and maximum bulk shear strains of 3. Peak shear stress was about 20 MPa for all the samples, followed by smooth weakening and steady state behavior. The strain is predominantly localized in the host marble within the process zone in front of the inclusion, defined by a zone of intense grain size reduction due to dynamic recrystallization. In CS tests a narrow shear zone developed in front of the inclusion, whereas in CSR experiments the deformation is more heterogeneously distributed, up to g=3.. In the later, secondary foliations oblique to the process zone and alternating thin, high-strain layers are common. In samples deformed at the same shear strain (g=1), the average recrystallized grain size in the process zone is similar for CS and CSR conditions. Crystallographic preferred orientation (CPO) measurements shows that different grain sizes have slightly different CPO patterns. CPO strength varies for different grain sizes, with a CPO strength peak between 40-50 μm, decreasing progressively within smaller grain size, but with secondary peaks for different coarse-grained sizes. Our observations suggest that the initial formation and transient deformation of shear zones is strongly affected by loading conditions.

  4. Planar Hall effect bridge magnetic field sensors

    DEFF Research Database (Denmark)

    Henriksen, A.D.; Dalslet, Bjarke Thomas; Skieller, D.H.

    2010-01-01

    Until now, the planar Hall effect has been studied in samples with cross-shaped Hall geometry. We demonstrate theoretically and experimentally that the planar Hall effect can be observed for an exchange-biased ferromagnetic material in a Wheatstone bridge topology and that the sensor signal can...... Hall effect bridge sensors....

  5. Evaluating the Effects of Magnetic Susceptibility in UXO Discrimination Problems (SERDP SEED Project UX-1285)

    National Research Council Canada - National Science Library

    Pasion, Leonard R; Billings, Stephen D; Oldenburg, Douglas W; Sinex, David; Li, Yaoguo

    2003-01-01

    Using numerical simulations based on magnetic susceptibility properties observed at Kaho'olawe, Hawaii, we have examined the effect of magnetic soil on static magnetic method and time-domain electromagnetic (TEM...

  6. Radiation effects on insulators for superconducting magnets

    International Nuclear Information System (INIS)

    Kernohan, R.H.; Coltman, R.R. Jr.; Long, C.J.

    1978-01-01

    In order to determine the radiation stability of electrical insulation that could be used in a superconducting magnet for containment of the plasma in a fusion energy device, 55 specimens of eight types of organic insulation were irradiated to a dose of about 2 x 10 8 R (2 x 10 6 J/Kg) at a temperature of 4.8 K in the Low-Temperature Irradiation Facility in the Bulk Shielding Reactor at Oak Ridge National Laboratory. Four of the specimens were monitored for changes in electrical resistivity during the irradiation. The initial resistivities, which were of the order of 10 14 Ω cm, decreased to about 10 13 Ω cm under the influence of a weak radiation field. At full-power reactor operation (2 MW), the resistivities dropped to about 10 11 Ω cm, but changed little during the irradiation. After the irradiation the resistivities increased, but not to the initial values, because of residual radioactivity near or in the experiment assembly. Restoration to near the initial resistivity values was later observed upon warming the specimens to room temperature and purging the irradiation chamber. The latter result may be related to outgassing induced by the irradiation

  7. FARADAY ROTATION: EFFECT OF MAGNETIC FIELD REVERSALS

    International Nuclear Information System (INIS)

    Melrose, D. B.

    2010-01-01

    The standard formula for the rotation measure (RM), which determines the position angle, ψ = RMλ 2 , due to Faraday rotation, includes contributions only from the portions of the ray path where the natural modes of the plasma are circularly polarized. In small regions of the ray path where the projection of the magnetic field on the ray path reverses sign (called QT regions) the modes are nearly linearly polarized. The neglect of QT regions in estimating RM is not well justified at frequencies below a transition frequency where mode coupling changes from strong to weak. By integrating the polarization transfer equation across a QT region in the latter limit, I estimate the additional contribution Δψ needed to correct this omission. In contrast with a result proposed by Broderick and Blandford, Δψ is small and probably unobservable. I identify a new source of circular polarization, due to mode coupling in an asymmetric QT region. I also identify a new circular-polarization-dependent correction to the dispersion measure at low frequencies.

  8. FARADAY ROTATION: EFFECT OF MAGNETIC FIELD REVERSALS

    Energy Technology Data Exchange (ETDEWEB)

    Melrose, D B [SIfA, School of Physics, University of Sydney, NSW 2006 (Australia)

    2010-12-20

    The standard formula for the rotation measure (RM), which determines the position angle, {psi} = RM{lambda}{sup 2}, due to Faraday rotation, includes contributions only from the portions of the ray path where the natural modes of the plasma are circularly polarized. In small regions of the ray path where the projection of the magnetic field on the ray path reverses sign (called QT regions) the modes are nearly linearly polarized. The neglect of QT regions in estimating RM is not well justified at frequencies below a transition frequency where mode coupling changes from strong to weak. By integrating the polarization transfer equation across a QT region in the latter limit, I estimate the additional contribution {Delta}{psi} needed to correct this omission. In contrast with a result proposed by Broderick and Blandford, {Delta}{psi} is small and probably unobservable. I identify a new source of circular polarization, due to mode coupling in an asymmetric QT region. I also identify a new circular-polarization-dependent correction to the dispersion measure at low frequencies.

  9. Developmental effects of extremely low frequency electric and magnetic fields

    International Nuclear Information System (INIS)

    Juutilainen, J.

    2003-01-01

    Developmental effects of extremely low frequency (ELF) electric and magnetic fields are briefly reviewed in this paper. The results of animal studies on ELF electric fields are rather consistent, and do not suggest adverse effects on development. The results of studies on ELF magnetic fields suggest effects on bird embryo development, but not consistently in all studies. Results from experiments with other non-mammalian species have also suggested effects on developmental stability. In mammals, pre-natal exposure to ELF magnetic fields does not result in strong adverse effects on development. The only finding that shows some consistency is increase of minor skeleton alterations. Epidemiological studies do not establish an association between human adverse pregnancy outcomes and maternal exposure to ELF fields, although a few studies have reported increased risks associated with some characteristics of magnetic field exposure. Taken as a whole, the results do not show strong adverse effects on development. However, additional studies on the suggested subtle effects on developmental stability might increase our understanding of the sensitivity of organisms to weak ELF fields. (author)

  10. Spectropolarimetry of magnetic stars. IV. The crossover effect.

    Science.gov (United States)

    Mathys, G.

    1995-01-01

    This paper is devoted to the study of the crossover effect in magnetic Ap stars. It is shown that this effect can be measured by the second order moment about their centre of the profiles of spectral lines recorded in the Stokes parameter V. The interpretation of these measurements in terms of magnetic field is developed. It is shown that one can derive from them a quantity called the mean asymmetry of the longitudinal magnetic field, which is the first moment of the component of the magnetic field along the line of sight, about the plane defined by the line of sight and the stellar rotation axis. The consistency of the determination of this quantity with that of the mean longitudinal magnetic field from measurements of wavelength shifts of lines between right and left circular polarization is demonstrated. This technique of analysis is applied to observations of a sample of 29 stars, among which 10 have a detectable crossover effect. For 8 of them, the available observational data allow the study of the variations of the asymmetry of the longitudinal field with rotation phase. In most cases, this variation is sinusoidal and essentially symmetric about 0, and it occurs in quadrature with the variation of the mean longitudinal field. A more complex behaviour is definitely observed in HD 147010 and HD 175362, where the variation of the asymmetry of the longitudinal field is better represented by the superposition of two sinusoids, one with the rotation frequency of the star, and the other with twice that frequency.

  11. Magnetic effects in heavy-ion collisions at intermediate energies

    International Nuclear Information System (INIS)

    Ou Li; Li Baoan

    2011-01-01

    The time evolution and space distribution of internal electromagnetic fields in heavy-ion reactions at beam energies between 200 and 2000 MeV/nucleon are studied within an isospin-dependent Boltzmann-Uhling-Uhlenbeck transport model (ibuu11). While the magnetic field can reach about 7x10 16 G, which is significantly higher than the estimated surface magnetic field (∼1x10 15 G) of magnetars, it has almost no effect on nucleon observables because the Lorentz force is normally much weaker than the nuclear force. Very interestingly, however, the magnetic field generated by the projectilelike (targetlike) spectator has a strong focusing and defocusing effect on positive and negative pions at forward (backward) rapidities. Consequently, the differential π - /π + ratio as a function of rapidity is significantly altered by the magnetic field, whereas the total multiplicities of both positive and negative pions remain about the same. At beam energies above about 1 GeV/nucleon, while the integrated ratio of total π - to π + multiplicities is not, the differential π - /π + ratio is sensitive to the density dependence of nuclear symmetry energy E sym (ρ). Our findings suggest that magnetic effects should be carefully considered in future studies of using the differential π - /π + ratio as a probe of the E sym (ρ) at suprasaturation densities.

  12. Effect of Weak Magnetic Field on Bacterial Growth

    Science.gov (United States)

    Masood, Samina

    Effects of weak magnetic fields are observed on the growth of various bacterial strains. Different sources of a constant magnetic field are used to demonstrate that ion transport in the nutrient broth and bacterial cellular dynamics is perturbed in the presence of weak magnetic field which affects the mobility and absorption of nutrients in cells and hence their doubling rate. The change is obvious after a few hours of exposure and keeps on increasing with time for all the observed species. The growth rate depends on the field strength and the nature of the magnetic field. The field effect varies with the shape and the structure of the bacterial cell wall as well as the concentration of nutrient broth. We closely study the growth of three species Escherichia coli, Pseudomonas aeruginosa and Staphylococcus epidermidis with the same initial concentrations at the same temperature in the same laboratory environment. Our results indicate that the weak static field of a few gauss after a few hours gives a measurable change in the growth rates of all bacterial species. This shows that the same magnetic field has different effects on different species in the same environment.

  13. Stern-Gerlach effect without magnetic-field gradient

    International Nuclear Information System (INIS)

    Zimmer, O.; Felber, J.; Schaerpf, O.

    2001-01-01

    The Stern-Gerlach effect is the well-known spin-dependent splitting of a neutral particle beam by a magnetic-field gradient. Guided by the pseudomagnetic analogy, we performed a similar experiment where no magnetic-field gradient is involved. The effect is due to the spin-dependence of neutron scattering from polarised nuclei, i.e. caused by the strong interaction between neutrons and nuclei. The beam splitting is proportional to the nuclear polarisation and to the spin-dependent part of the neutron scattering length. Thus it can be used to measure one of both quantities. (orig.)

  14. Effects of magnetic atoms on the properties of ternary superconductors

    International Nuclear Information System (INIS)

    Dunlap, B.D.; Shenoy, G.K.

    1980-01-01

    Until recently it has been commonly accepted that small impurities of magnetic atoms were severely detrimental to superconductivity, and that superconductivity and long-range magnetic ordering could not occur in the same materials. In known binary and pseudo-binary compounds, this is still the case. However, many recent experiments on ternary superconductors have shown that the effects of magnetism are considerably more complex. In some cases, the addition of magnetic atoms has been found to enhance superconducting properties by increasing the superconducting critical field, without significantly lowering the transition temperature. In many cases, compounds will show both superconducting and long range magnetic ordering transitions. The destruction of superconductivity by ferromagnetic ordering and the coexistence of superconductivity with antiferromagnetic ordering is now well established. Hyperfine interaction measurements have played a significant role in the investigations of these materials, including measurement of the magnitude of the exchange interaction between rare-earth spin and conduction electron spin, elucidation of the mechanism for critical field enhancement, specification of crystalline field ground states, and studies of the nature of magnetic ordering

  15. Magnetic property effect on transport processes in resistance spot welding

    Energy Technology Data Exchange (ETDEWEB)

    Wei, P S [Department of Mechanical and Electro-Mechanical Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan 80424 (China); Wu, T H, E-mail: pswei@mail.nsysu.edu.tw, E-mail: wux0064@gmail.com [Department of Mechanical Engineering, Yung Ta Institute of Technology and Commerce, Pintong, Taiwan 909 (China)

    2011-08-17

    This study investigates the effects of the Curie temperature and magnetic permeability on transport variables, solute distribution and nugget shapes during resistance spot welding. The Curie temperature is the temperature below which a metal or alloy is ferromagnetic with a high magnetic permeability, and above which it is paramagnetic with a small magnetic permeability. The model proposed here accounts for electromagnetic force, heat generation and contact resistance at the faying surface and electrode-workpiece interfaces and bulk resistance in workpieces. Contact resistance includes constriction and film resistances, which are functions of hardness, temperature, electrode force and surface condition. The computed results show that transport variables and nugget shapes can be consistently interpreted from the delay of response time and jump of electric current density as a result of finite magnetic diffusion, rather than through the examination of the variations of dynamic electrical resistance with time. The molten nugget on the faying surface is initiated earlier with increasing magnetic permeability and Curie temperature. A high Curie temperature enhances convection and solute mixing, and readily melts through the workpiece surface near the electrode edge. Any means to reduce the Curie temperature or magnetic permeability, such as adjusting the solute content, can be a good way to control weld quality. This study can also be applied to interpret the contact problems encountered in various electronics and packaging technologies, and so on.

  16. Magnetic field effects on the crust structure of neutron stars

    Science.gov (United States)

    Franzon, B.; Negreiros, R.; Schramm, S.

    2017-12-01

    We study the effects of high magnetic fields on the structure and on the geometry of the crust in neutron stars. We find that the crust geometry is substantially modified by the magnetic field inside the star. We build stationary and axis-symmetric magnetized stellar models by using well-known equations of state to describe the neutron star crust, namely, the Skyrme model for the inner crust and the Baym-Pethick-Sutherland equation of state for the outer crust. We show that the magnetic field has a dual role, contributing to the crust deformation via the electromagnetic interaction (manifested in this case as the Lorentz force) and by contributing to curvature due to the energy stored in it. We also study a direct consequence of the crust deformation due to the magnetic field: the thermal relaxation time. This quantity, which is of great importance to the thermal evolution of neutron stars, is sensitive to the crust properties, and, as such, we show that it may be strongly affected by the magnetic field.

  17. Influence of magnetic disorders on quantum anomalous Hall effect in magnetic topological insulator films beyond the two-dimensional limit

    Science.gov (United States)

    Xing, Yanxia; Xu, Fuming; Cheung, King Tai; Sun, Qing-feng; Wang, Jian; Yao, Yugui

    2018-04-01

    Quantum anomalous Hall effect (QAHE) has been experimentally realized in magnetic topological insulator (MTI) thin films fabricated on magnetically doped {({{Bi}},{{Sb}})}2{{{Te}}}3. In an MTI thin film with the magnetic easy axis along the normal direction (z-direction), orientations of magnetic dopants are randomly distributed around the magnetic easy axis, acting as magnetic disorders. With the aid of the non-equilibrium Green's function and Landauer–Büttiker formalism, we numerically study the influence of magnetic disorders on QAHE in an MTI thin film modeled by a three-dimensional tight-binding Hamiltonian. It is found that, due to the existence of gapless side surface states, QAHE is protected even in the presence of magnetic disorders as long as the z-component of magnetic moment of all magnetic dopants are positive. More importantly, such magnetic disorders also suppress the dissipation of the chiral edge states and enhance the quality of QAHE in MTI films. In addition, the effect of magnetic disorders depends very much on the film thickness, and the optimal influence is achieved at certain thickness. These findings are new features for QAHE in three-dimensional systems, not present in two-dimensional systems.

  18. Effects of drain-wall in mitigating N-hit single event transient via 45 nm CMOS process

    International Nuclear Information System (INIS)

    Xu, X Y; Tang, M H; Xiao, Y G; Yan, S A; Zhang, W L; Li, Z; Xiong, Y; Zhao, W; Guo, H X

    2015-01-01

    A three-dimensional (3D) technology computer-aided design (TCAD) simulation in a novel layout technique for N-hit single event transient (SET) mitigation based on drain-wall layout technique is proposed. Numerical simulations of both single-device and mixed-mode show that the proposed layout technique designed with 45 nm CMOS process can efficiently reduce not only charge collection but also SET pulse widths (W SET ). What is more, simulations show that impacts caused by part of ion-incidents can be shielded with this novel layout technique. When compared with conventional layout technique and guard drain layout technique, we find that the proposed novel layout technique can provide the best benefit of SET mitigation with a small sacrifice in effective area. (paper)

  19. The quaternary lidocaine derivative, QX-314, exerts biphasic effects on transient receptor potential vanilloid subtype 1 channels in vitro

    DEFF Research Database (Denmark)

    Rivera-Acevedo, Ricardo E; Pless, Stephan Alexander; Ahern, Christopher A

    2011-01-01

    concentrations (less than 1 mM), QX-314 potently inhibited capsaicin-evoked TRPV1 currents with an IC₅₀ of 8.0 ± 0.6 μM. CONCLUSIONS: The results of this study show that the quaternary lidocaine derivative QX-314 exerts biphasic effects on TRPV1 channels, inhibiting capsaicin-evoked TRPV1 currents at lower...... channels. METHODS: The authors conducted an in vitro laboratory study in which they expressed TRPV1 and TRPV4 channels in Xenopus laevis oocytes and recorded cation currents with the two-electrode voltage clamp method. They used confocal microscopy for Ca²⁺ imaging in TRPV1 transient transfected tsA201...

  20. Kondo effect in single-molecule magnet transistors

    Science.gov (United States)

    Gonzalez, Gabriel; Leuenberger, Michael; Mucciolo, Eduardo

    2009-03-01

    We present a careful and thorough microscopic derivation of the anisotropic Kondo Hamiltonian for single-molecule magnet (SMM) transistors. When the molecule is strongly coupled to metallic leads, we show that by applying a transverse magnetic field it is possible to topologically induce or quench the Kondo effect in the conductance of a SMM with either an integer or a half-integer spin S>1/2. This topological Kondo effect is due to the Berry-phase interference between multiple quantum tunneling paths of the spin. We calculate the renormalized Berry-phase oscillations of the two Kondo peaks as a function of a transverse magnetic field by means of the poor man's scaling approach. We illustrate our findings with the SMM Ni4, which we propose as a possible candidate for the experimental observation of the conductance oscillations.