WorldWideScience

Sample records for transient current technique

  1. Principle of the electrically induced Transient Current Technique

    Science.gov (United States)

    Bronuzzi, J.; Moll, M.; Bouvet, D.; Mapelli, A.; Sallese, J. M.

    2018-05-01

    In the field of detector development for High Energy Physics, the so-called Transient Current Technique (TCT) is used to characterize the electric field profile and the charge trapping inside silicon radiation detectors where particles or photons create electron-hole pairs in the bulk of a semiconductor device, as PiN diodes. In the standard approach, the TCT signal originates from the free carriers generated close to the surface of a silicon detector, by short pulses of light or by alpha particles. This work proposes a new principle of charge injection by means of lateral PN junctions implemented in one of the detector electrodes, called the electrical TCT (el-TCT). This technique is fully compatible with CMOS technology and therefore opens new perspectives for assessment of radiation detectors performances.

  2. Current interruption transients calculation

    CERN Document Server

    Peelo, David F

    2014-01-01

    Provides an original, detailed and practical description of current interruption transients, origins, and the circuits involved, and how they can be calculated Current Interruption Transients Calculationis a comprehensive resource for the understanding, calculation and analysis of the transient recovery voltages (TRVs) and related re-ignition or re-striking transients associated with fault current interruption and the switching of inductive and capacitive load currents in circuits. This book provides an original, detailed and practical description of current interruption transients, origins,

  3. FORTRAN programs for transient eddy current calculations using a perturbation-polynomial expansion technique

    International Nuclear Information System (INIS)

    Carpenter, K.H.

    1976-11-01

    A description is given of FORTRAN programs for transient eddy current calculations in thin, non-magnetic conductors using a perturbation-polynomial expansion technique. Basic equations are presented as well as flow charts for the programs implementing them. The implementation is in two steps--a batch program to produce an intermediate data file and interactive programs to produce graphical output. FORTRAN source listings are included for all program elements, and sample inputs and outputs are given for the major programs

  4. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    Science.gov (United States)

    Krauter, N.; Stefani, F.

    2017-10-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation.

  5. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    International Nuclear Information System (INIS)

    Krauter, N; Stefani, F

    2017-01-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation. (paper)

  6. Transport properties of triarylamine based dendrimers studied by space charge limited current transients

    Science.gov (United States)

    Szymanski, Marek Z.; Kulszewicz-Bajer, Irena; Faure-Vincent, Jérôme; Djurado, David

    2012-08-01

    We have studied hole transport in triarylamine based dendrimer using space-charge-limited current transient technique. A mobility of 8 × 10-6 cm2/(V s) and a characteristic detrapping time of about 100 ms have been obtained. We found that quasi-ohmic contact is formed with gold. The obtained mobility differs from the apparent one given by the analysis of stationary current-voltage characteristics because of a limited contact efficiency. The comparison between transients obtained from fresh and aged samples reveals no change in mobility with aging. The deterioration of electrical properties is exclusively caused by trap formation and accumulation of ionic conducting impurities. Finally, repeated transient measurements have been applied to analyze the dynamics of charge trapping process.

  7. Plasma transport studies using transient techniques

    International Nuclear Information System (INIS)

    Simonen, T.C.; Brower, D.L.; Efthimion, P.

    1991-01-01

    Selected topics from the Transient Transport sessions of the Transport Task Force Workshop, held February 19-23, 1990, in Hilton Head, South Carolina are summarized. Presentations on sawtooth propagation, ECH modulation, particle modulation, and H-mode transitions are included. The research results presented indicated a growing theoretical understanding and experimental sophistication in the application of transient techniques to transport studies. (Author)

  8. Transient and steady-state currents in epoxy resin

    International Nuclear Information System (INIS)

    Guillermin, Christophe; Rain, Pascal; Rowe, Stephen W

    2006-01-01

    Charging and discharging currents have been measured in a diglycidyl ether of bisphenol-A epoxy resin with and without silica fillers, below and above its glass transition temperature T g = 65 deg. C. Both transient and steady-state current densities have been analysed. The average applied fields ranged from 3 to 35 kV mm -1 with a sample thickness of 0.5 mm. Above T g , transient currents suggested a phenomenon of charge injection forming trapped space charges even at low fields. Steady-state currents confirmed that the behaviour was not Ohmic and suggested Schottky-type injection. Below T g , the current is not controlled by the metal-dielectric interface but by the conduction in the volume: the current is Ohmic at low fields and both transient and steady-state currents suggest a phenomenon of space-charge limited currents at high fields. The field threshold is similar in the filler-free and the filled resin. Values in the range 12-17 kV mm -1 have been measured

  9. Transient and steady-state currents in epoxy resin

    Energy Technology Data Exchange (ETDEWEB)

    Guillermin, Christophe [Schneider Electric Industries S.A.S., 37 quai Paul-Louis Merlin, 38050 Grenoble Cedex 9 (France); Rain, Pascal [Laboratoire d' Electrostatique et de Materiaux Dielectriques (LEMD), CNRS, 25 avenue des Martyrs, 38042 Grenoble Cedex 9 (France); Rowe, Stephen W [Schneider Electric Industries S.A.S., 37 quai Paul-Louis Merlin, 38050 Grenoble Cedex 9 (France)

    2006-02-07

    Charging and discharging currents have been measured in a diglycidyl ether of bisphenol-A epoxy resin with and without silica fillers, below and above its glass transition temperature T{sub g} = 65 deg. C. Both transient and steady-state current densities have been analysed. The average applied fields ranged from 3 to 35 kV mm{sup -1} with a sample thickness of 0.5 mm. Above T{sub g}, transient currents suggested a phenomenon of charge injection forming trapped space charges even at low fields. Steady-state currents confirmed that the behaviour was not Ohmic and suggested Schottky-type injection. Below T{sub g}, the current is not controlled by the metal-dielectric interface but by the conduction in the volume: the current is Ohmic at low fields and both transient and steady-state currents suggest a phenomenon of space-charge limited currents at high fields. The field threshold is similar in the filler-free and the filled resin. Values in the range 12-17 kV mm{sup -1} have been measured.

  10. 3-D transient eddy current calculations for the FELIX cylinder experiments

    International Nuclear Information System (INIS)

    Davey, K.R.; Turner, L.R.

    1986-12-01

    The three-dimensional eddy current transient field problem is formulated first using the U-V method. This method breaks the vector Helmholtz equation into two scalar Helmholtz equations. Null field integral equations and the appropriate boundary conditions are used to set up an identification matrix which is independent of null field point locations. Embedded in the identification matrix are the unknown eigenvalues of the problem representing its impulse response in time. These eigenvalues are found by equating the determinant of the identification matrix to zero. When this initial forcing function is Fourier decomposed into its spatial harmonics, each Fourier component can be associated with a unique eigenvalue by this technique. The true transient solution comes through a convolution of the impulse response so obtained with the particular external field decay governing the problem at hand. The technique is applied to the FELIX cylinder experiments; computed results are compared to data. A pseudoanalytic confirmation of the eigenvalues so obtained is formulated to validate the procedure

  11. Principle and modelling of Transient Current Technique for interface traps characterization in monolithic pixel detectors obtained by CMOS-compatible wafer bonding

    CERN Document Server

    Bronuzzi, J.; Moll, M.; Sallese, J.M.

    2016-01-01

    In the framework of monolithic silicon radiation detectors, a fabrication process based on a recently developed silicon wafer bonding technique at low temperature was proposed. Ideally, this new process would enable direct bonding of a read-out electronic chip wafer on a highly resistive silicon substrate wafer, which is expected to present many advantages since it would combine high performance IC's with high sensitive ultra-low doped bulk silicon detectors. But electrical properties of the bonded interface are critical for this kind of application since the mobile charges generated by radiation inside the bonded bulk are expected to transit through the interface in order to be collected by the read-out electronics. In this work, we propose to explore and develop a model for the so-called Transient Current Technique (TCT) to identify the presence of deep traps at the bonded interface. For this purpose, we consider a simple PIN diode reversely biased where the ultra-low doped active region of interest is set ...

  12. Transient current induced in thin film diamonds by swift heavy ions

    International Nuclear Information System (INIS)

    Sato, Shin-ichiro; Makino, Takahiro; Ohshima, Takeshi; Kamiya, Tomihiro; Kada, Wataru

    2017-01-01

    Single crystal diamond is a suitable material for the next generation particle detectors because of the superior electrical properties and the high radiation tolerance. In order to investigate charge transport properties of diamond particle detectors, transient currents generated in diamonds by single swift heavy ions (26 MeV O 5+ and 45 MeV Si 7+ ) are investigated. We also measured two dimensional maps of transient currents by single ion hits. In the case of 50 μm-thick diamond, both the signal height and the collected charge are reduced by the subsequent ion hits and the charge collection time is extended. Our results are thought to be attributable to the polarization effect in diamond and it appears only when the transient current is dominated by hole current. In the case of 6 μm-thick diamond membrane, an “island” structure is found in the 2D map of transient currents. Signals in the islands shows different applied bias dependence from signals in other regions, indicating different crystal and/or metal contact quality. Simulation study of transient currents based on the Shockley-Ramo theorem clarifies that accumulation of space charges changes distribution of electric field in diamond and causes the polarization effect.

  13. Simulation study and experimental results for detection and classification of the transient capacitor inrush current using discrete wavelet transform and artificial intelligence

    Directory of Open Access Journals (Sweden)

    Patcharoen Theerasak

    2018-04-01

    Full Text Available This paper describes the combination of discrete wavelet transforms (DWT and artificial intelligence (AI, which are efficient techniques to identify the type of inrush current, analyze the origin and possible cause on the capacitor bank switching. The experiment setup used to verify the proposed techniques can be detected and classified the transient inrush current from normal capacitor rated current. The discrete wavelet transforms are used to detect and classify the inrush current. Then, output from wavelet is acted as input of fuzzy inference system for discriminating the type of switching transient inrush current. The proposed technique shows enhanced performance with a discrimination accuracy of 90.57%. Both simulation study and experimental results are quite satisfactory with providing the high accuracy and reliability which can be developed and implemented into a numerical overcurrent (50/51 and unbalanced current (60C protection relay for an application of shunt capacitor bank protection in the future.

  14. Simulation study and experimental results for detection and classification of the transient capacitor inrush current using discrete wavelet transform and artificial intelligence

    Science.gov (United States)

    Patcharoen, Theerasak; Yoomak, Suntiti; Ngaopitakkul, Atthapol; Pothisarn, Chaichan

    2018-04-01

    This paper describes the combination of discrete wavelet transforms (DWT) and artificial intelligence (AI), which are efficient techniques to identify the type of inrush current, analyze the origin and possible cause on the capacitor bank switching. The experiment setup used to verify the proposed techniques can be detected and classified the transient inrush current from normal capacitor rated current. The discrete wavelet transforms are used to detect and classify the inrush current. Then, output from wavelet is acted as input of fuzzy inference system for discriminating the type of switching transient inrush current. The proposed technique shows enhanced performance with a discrimination accuracy of 90.57%. Both simulation study and experimental results are quite satisfactory with providing the high accuracy and reliability which can be developed and implemented into a numerical overcurrent (50/51) and unbalanced current (60C) protection relay for an application of shunt capacitor bank protection in the future.

  15. Determination of the diffusion coefficient of oxygen in sodium chloride solutions with a transient pulse technique

    NARCIS (Netherlands)

    van Stroe, A.J.; Janssen, L.J.J.

    1993-01-01

    An accurate and rapid method for detg. the diffusion coeffs. of electrochem. active gases in electrolytes is described. The technique is based on chronoamperometry where transient currents are measured and interpreted with a Cottrell-related equation. The diffusion coeffs. of oxygen were detd. for

  16. Transient currents in a molecular photo-diode

    OpenAIRE

    Petrov, E. G.; Leonov, V. O.; May, V.; Hänggi, P.

    2012-01-01

    Light-induced charge transmission through a molecular junction (molecular diode) is studied in the framework of a HOMO-LUMO model and in using a kinetic description. Expressions are presented for the sequential (hopping) and direct (tunneling) transient current components together with kinetic equations governing the time-dependent populations of the neutral and charged molecular states which participate in the current formation. Resonant and off-resonant charge transmission processes are ana...

  17. Transient voltage response of a superconducting strip to a supercritical current pulse

    International Nuclear Information System (INIS)

    Attekum, P.M.Th.M. van; Wouters, M.C.H.M.; Wolter, J.; Horstman, R.E.

    1981-01-01

    A superconductor subject to a supercritical current pulse displays a delay time between the onset of the current pulse and the onset of the corresponding voltage response. From the onset of the voltage response it takes a second (transient) time to reach the stationary state. It is shown that the transient time can be explained with inhomogeneities in the strip which give rise to a distribution of delay times. The transient time is thus not related to a characteristic time in the superconductor. For small supercritical currents also heating effects show up. (author)

  18. Study of water flowrate using time transient and cross-correlation techniques with 82Br radiotracer

    International Nuclear Information System (INIS)

    Salgado, William L.; Brandao, Luiz E.B.

    2013-01-01

    This paper aims to determinate the water flowrate using Time Transient and Cross-Correlation techniques. The detection system uses two NaI (T1) detectors adequately positioned on the outside of pipe and a gamma-ray source ( 82 Br radiotracer). The water flowrate measurements using Time Transient and Cross-Correlation techniques were compared to invasive conventional measurements of the flowrate previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowmeter previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowrate values were found to be less than 3% in relation to conventional ones. (author)

  19. Electric fields associated with transient surface currents

    DEFF Research Database (Denmark)

    McAllister, Iain Wilson

    1992-01-01

    The boundary condition to be fulfilled by the potential functions associated with a transient surface current is derived and expressed in terms of generalized orthogonal coordinates. From the analysis, it can be deduced that the use of the method of separation of variables is restricted to three ...

  20. Evaluating transient performance of servo mechanisms by analysing stator current of PMSM

    Science.gov (United States)

    Zhang, Qing; Tan, Luyao; Xu, Guanghua

    2018-02-01

    Smooth running and rapid response are the desired performance goals for the transient motions of servo mechanisms. Because of the uncertain and unobservable transient behaviour of servo mechanisms, it is difficult to evaluate their transient performance. Under the effects of electromechanical coupling, the stator current signals of a permanent-magnet synchronous motor (PMSM) potentially contain the performance information regarding servo mechanisms in use. In this paper, a novel method based on analysing the stator current of the PMSM is proposed for quantifying the transient performance. First, a vector control model is constructed to simulate the stator current behaviour in the transient processes of consecutive speed changes, consecutive load changes, and intermittent start-stops. It is discovered that the amplitude and frequency of the stator current are modulated by the transient load torque and motor speed, respectively. The stator currents under different performance conditions are also simulated and compared. Then, the stator current is processed using a local means decomposition (LMD) algorithm to extract the instantaneous amplitude and instantaneous frequency. The sample entropy of the instantaneous amplitude, which reflects the complexity of the load torque variation, is calculated as a performance indicator of smooth running. The peak-to-peak value of the instantaneous frequency, which defines the range of the motor speed variation, is set as a performance indicator of rapid response. The proposed method is applied to both simulated data in an intermittent start-stops process and experimental data measured for a batch of servo turrets for turning lathes. The results show that the performance evaluations agree with the actual performance.

  1. Transient particle emission measurement with optical techniques

    Science.gov (United States)

    Bermúdez, Vicente; Luján, José M.; Serrano, José R.; Pla, Benjamín

    2008-06-01

    Particulate matter is responsible for some respiratory and cardiovascular diseases. In addition, it is one of the most important pollutants of high-speed direct injection (HSDI) passenger car engines. Current legislation requires particulate dilution tunnels for particulate matter measuring. However for development work, dilution tunnels are expensive and sometimes not useful since they are not able to quantify real-time particulate emissions during transient operation. In this study, the use of a continuous measurement opacimeter and a fast response HFID is proven to be a good alternative to obtain instantaneous particle mass emissions during transient operation (due to particulate matter consisting mainly of soot and SOF). Some methods and correlations available from literature, but developed for steady conditions, are evaluated during transient operation by comparing with mini-tunnel measurements during the entire MVEG-A transient cycle. A new correlation was also derived from this evaluation. Results for soot and SOF (obtained from the new correlation proposed) are compared with soot and SOF captured with particulate filters, which have been separated by means of an SOF extraction method. Finally, as an example of ECU design strategies using these sort of correlations, the EGR valve opening is optimized during transient operation. The optimization is performed while simultaneously taking into account instantaneous fuel consumption, particulate emissions (calculated with the proposed correlation) and other regulated engine pollutants.

  2. Current capabilities of transient two-phase flow instruments

    International Nuclear Information System (INIS)

    Solbrig, C.W.; Kondic, N.N.

    1979-01-01

    The measurement of two phase flow phenomena in transient conditions representative of a Loss-of-Coolant Accident requires the use of sophisticated instruments and the further development of other instruments. Measurements made in large size pipes are often flow regime dependent. The flow regimes encountered depend upon the system geometry, transient effects, heat transfer, etc. The geometries in which these measurements must be made, the instruments which are currently used, new instruments being developed, the facilities used to calibrate these instruments, and the improvements which must be made to measurement capabilities are described

  3. Profiling of barrier capacitance and spreading resistance using a transient linearly increasing voltage technique.

    Science.gov (United States)

    Gaubas, E; Ceponis, T; Kusakovskij, J

    2011-08-01

    A technique for the combined measurement of barrier capacitance and spreading resistance profiles using a linearly increasing voltage pulse is presented. The technique is based on the measurement and analysis of current transients, due to the barrier and diffusion capacitance, and the spreading resistance, between a needle probe and sample. To control the impact of deep traps in the barrier capacitance, a steady state bias illumination with infrared light was employed. Measurements of the spreading resistance and barrier capacitance profiles using a stepwise positioned probe on cross sectioned silicon pin diodes and pnp structures are presented.

  4. Current status of the transient integral fuel element performance code URANUS

    International Nuclear Information System (INIS)

    Preusser, T.; Lassmann, K.

    1983-01-01

    To investigate the behavior of fuel pins during normal and off-normal operation, the integral fuel rod code URANUS has been extended to include a transient version. The paper describes the current status of the program system including a presentation of newly developed models for hypothetical accident investigation. The main objective of current development work is to improve the modelling of fuel and clad material behavior during fast transients. URANUS allows detailed analysis of experiments until the onset of strong material transport phenomena. Transient fission gas analysis is carried out due to the coupling with a special version of the LANGZEIT-KURZZEIT-code (KfK). Fuel restructuring and grain growth kinetics models have been improved recently to better characterize pre-experimental steady-state operation; transient models are under development. Extensive verification of the new version has been carried out by comparison with analytical solutions, experimental evidence, and code-to-code evaluation studies. URANUS, with all these improvements, has been successfully applied to difficult fast breeder fuel rod analysis including TOP, LOF, TUCOP, local coolant blockage and specific carbide fuel experiments. Objective of further studies is the description of transient PCMI. It is expected that the results of these developments will contribute significantly to the understanding of fuel element structural behavior during severe transients. (orig.)

  5. Transient analysis for alternating over-current characteristics of HTSC power transmission cable

    Science.gov (United States)

    Lim, S. H.; Hwang, S. D.

    2006-10-01

    In this paper, the transient analysis for the alternating over-current distribution in case that the over-current was applied for a high-TC superconducting (HTSC) power transmission cable was performed. The transient analysis for the alternating over-current characteristics of HTSC power transmission cable with multi-layer is required to estimate the redistribution of the over-current between its conducting layers and to protect the cable system from the over-current in case that the quench in one or two layers of the HTSC power cable happens. For its transient analysis, the resistance generation of the conducting layers for the alternating over-current was reflected on its equivalent circuit, based on the resistance equation obtained by applying discrete Fourier transform (DFT) for the voltage and the current waveforms of the HTSC tape, which comprises each layer of the HTSC power transmission cable. It was confirmed through the numerical analysis on its equivalent circuit that after the current redistribution from the outermost layer into the inner layers first happened, the fast current redistribution between the inner layers developed as the amplitude of the alternating over-current increased.

  6. Management of high current transients in the CWDD Injector 200 kV power system

    International Nuclear Information System (INIS)

    Carwardine, J.A.; Pile, G.; Zinneman, T.E.

    1993-01-01

    The injector for the Continuous Wave Deuterium Demonstrator is designed to deliver a high current CW negative deuterium ion beam at an energy of 200 keV to a Radio Frequency Quadrupole. The injector comprises a volume ion source, triode accelerator, high-power electron traps and low-energy beam transport with a single focusing solenoid. Some 75 Joules of energy are stored in stray capacitance around the high voltage system and discharged in a few microseconds following an injector breakdown. In order to limit damage to the accelerator grids, a magnetic snubber is incorporated to absorb most of the energy. Nevertheless, large current transients flow around the system as a result of an injector breakdown; these have frequently damaged power components and caused spurious behavior in many of the supporting systems. The analytical and practical approaches taken to minimize the effects of these transients are described. Injector breakdowns were simulated using an air spark gap and measurements made using standard EMC test techniques. The power circuit was modeled using an electrical simulation code; good agreement was reached between the model and measured results

  7. Emergence of currents as a transient quantum effect in nonequilibrium systems

    Energy Technology Data Exchange (ETDEWEB)

    Granot, Er' el; Marchewka, Avi [Department of Electrical and Electronics Engineering, Ariel University Center of Samaria, Ariel (Israel)

    2011-09-15

    Most current calculations are based on equilibrium or semi-equilibrium models. However, except for very special scenarios (like ring configuration), the current cannot exist in equilibrium. Moreover, unlike with equilibrium scenarios, there is no generic approach to confront out-of-equilibrium currents. In this paper we used recent studies on transient quantum mechanics to solve the current, which appears in the presence of very high density gradients and fast transients. It shows that the emerging current appears instantaneously, and although the density beyond the discontinuity is initially negligible the currents there have a finite value, and remain constant for a finite period. It is shown that this nonequilibrium effect can be measured in real experiments (such as cooled rubidium atoms), where the discontinuity is replaced with a finite width (hundreds of nanometers) gradient.

  8. Emergence of currents as a transient quantum effect in nonequilibrium systems

    International Nuclear Information System (INIS)

    Granot, Er'el; Marchewka, Avi

    2011-01-01

    Most current calculations are based on equilibrium or semi-equilibrium models. However, except for very special scenarios (like ring configuration), the current cannot exist in equilibrium. Moreover, unlike with equilibrium scenarios, there is no generic approach to confront out-of-equilibrium currents. In this paper we used recent studies on transient quantum mechanics to solve the current, which appears in the presence of very high density gradients and fast transients. It shows that the emerging current appears instantaneously, and although the density beyond the discontinuity is initially negligible the currents there have a finite value, and remain constant for a finite period. It is shown that this nonequilibrium effect can be measured in real experiments (such as cooled rubidium atoms), where the discontinuity is replaced with a finite width (hundreds of nanometers) gradient.

  9. Emergence of currents as a transient quantum effect in nonequilibrium systems

    Science.gov (United States)

    Granot, Er'El; Marchewka, Avi

    2011-09-01

    Most current calculations are based on equilibrium or semi-equilibrium models. However, except for very special scenarios (like ring configuration), the current cannot exist in equilibrium. Moreover, unlike with equilibrium scenarios, there is no generic approach to confront out-of-equilibrium currents. In this paper we used recent studies on transient quantum mechanics to solve the current, which appears in the presence of very high density gradients and fast transients. It shows that the emerging current appears instantaneously, and although the density beyond the discontinuity is initially negligible the currents there have a finite value, and remain constant for a finite period. It is shown that this nonequilibrium effect can be measured in real experiments (such as cooled rubidium atoms), where the discontinuity is replaced with a finite width (hundreds of nanometers) gradient.

  10. Calculations of transient fields in the Felix experiments at Argonne using null field integrated techniques

    International Nuclear Information System (INIS)

    Han, H.C.; Davey, K.R.; Turner, L.

    1985-08-01

    The transient eddy current problem is characteristically computationally intensive. The motivation for this research was to realize an efficient, accurate, solution technique involving small matrices via an eigenvalue approach. Such a technique is indeed realized and tested using the null field integral technique. Using smart (i.e., efficient, global) basis functions to represent unknowns in terms of a minimum number of unknowns, homogeneous eigenvectors and eigenvalues are first determined. The general excitatory response is then represented in terms of these eigenvalues/eigenvectors. Excellent results are obtained for the Argonne Felix cylinder experiments using a 4 x 4 matrix. Extension to the 3-D problem (short cylinder) is set up in terms of an 8 x 8 matrix

  11. Scanning transient current study of the I-V stabilization phenomena in silicon detectors irradiated by fast neutrons

    International Nuclear Information System (INIS)

    Eremin, V.; Verbitskaya, E.; Sidorov, A.; Fretwurst, E.; Lindstrom, G.

    1996-03-01

    Investigation of the I-V stabilization phenomena in neutron irradiated silicon detectors has been carried out using scanning transient current technique (STCT) on non-irradiated PP + -p-n + detectors. The PP + -p-n + detectors were used to simulate the PP + -n-n + detectors irradiated beyond the space charge sign inversion (SCSI). Two mechanisms partially responsible for the I- V stabilization have been identified

  12. High-resolution three-dimensional imaging of a depleted CMOS sensor using an edge Transient Current Technique based on the Two Photon Absorption process (TPA-eTCT)

    CERN Document Server

    García, Marcos Fernández; Echeverría, Richard Jaramillo; Moll, Michael; Santos, Raúl Montero; Moya, David; Pinto, Rogelio Palomo; Vila, Iván

    2016-01-01

    For the first time, the deep n-well (DNW) depletion space of a High Voltage CMOS sensor has been characterized using a Transient Current Technique based on the simultaneous absorption of two photons. This novel approach has allowed to resolve the DNW implant boundaries and therefore to accurately determine the real depleted volume and the effective doping concentration of the substrate. The unprecedented spatial resolution of this new method comes from the fact that measurable free carrier generation in two photon mode only occurs in a micrometric scale voxel around the focus of the beam. Real three-dimensional spatial resolution is achieved by scanning the beam focus within the sample.

  13. High-resolution three-dimensional imaging of a depleted CMOS sensor using an edge Transient Current Technique based on the Two Photon Absorption process (TPA-eTCT)

    Energy Technology Data Exchange (ETDEWEB)

    García, Marcos Fernández; Sánchez, Javier González; Echeverría, Richard Jaramillo [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain); Moll, Michael [CERN, Organisation europénne pour la recherche nucléaire, CH-1211 Genéve 23 (Switzerland); Santos, Raúl Montero [SGIker Laser Facility, UPV/EHU, Sarriena, s/n - 48940 Leioa-Bizkaia (Spain); Moya, David [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain); Pinto, Rogelio Palomo [Departamento de Ingeniería Electrónica, Escuela Superior de Ingenieros Universidad de Sevilla (Spain); Vila, Iván [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain)

    2017-02-11

    For the first time, the deep n-well (DNW) depletion space of a High Voltage CMOS sensor has been characterized using a Transient Current Technique based on the simultaneous absorption of two photons. This novel approach has allowed to resolve the DNW implant boundaries and therefore to accurately determine the real depleted volume and the effective doping concentration of the substrate. The unprecedented spatial resolution of this new method comes from the fact that measurable free carrier generation in two photon mode only occurs in a micrometric scale voxel around the focus of the beam. Real three-dimensional spatial resolution is achieved by scanning the beam focus within the sample.

  14. Principle and modelling of Transient Current Technique for interface traps characterization in monolithic pixel detectors obtained by CMOS-compatible wafer bonding

    International Nuclear Information System (INIS)

    Bronuzzi, J.; Mapelli, A.; Moll, M.; Sallese, J.M.

    2016-01-01

    In the framework of monolithic silicon radiation detectors, a fabrication process based on a recently developed silicon wafer bonding technique at low temperature was proposed. Ideally, this new process would enable direct bonding of a read-out electronic chip wafer on a highly resistive silicon substrate wafer, which is expected to present many advantages since it would combine high performance IC's with high sensitive ultra-low doped bulk silicon detectors. But electrical properties of the bonded interface are critical for this kind of application since the mobile charges generated by radiation inside the bonded bulk are expected to transit through the interface in order to be collected by the read-out electronics. In this work, we propose to explore and develop a model for the so-called Transient Current Technique (TCT) to identify the presence of deep traps at the bonded interface. For this purpose, we consider a simple PIN diode reversely biased where the ultra-low doped active region of interest is set in full depletion. In a first step, Synopsys Sentaurus TCAD is used to evaluate the soundness of this technique for interface traps characterization such as it may happen in bonded interfaces. Next, an analytical model is developed in details to give a better insight into the physics behind the TCT for interface layers. Further, this can be used as a simple tool to evidence what are the relevant parameters influencing the TCT signal and to set the basis for preliminary characterizations.

  15. A point implicit time integration technique for slow transient flow problems

    Energy Technology Data Exchange (ETDEWEB)

    Kadioglu, Samet Y., E-mail: kadioglu@yildiz.edu.tr [Department of Mathematical Engineering, Yildiz Technical University, 34210 Davutpasa-Esenler, Istanbul (Turkey); Berry, Ray A., E-mail: ray.berry@inl.gov [Idaho National Laboratory, P.O. Box 1625, MS 3840, Idaho Falls, ID 83415 (United States); Martineau, Richard C. [Idaho National Laboratory, P.O. Box 1625, MS 3840, Idaho Falls, ID 83415 (United States)

    2015-05-15

    Highlights: • This new method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods. • It is unconditionally stable, as a fully implicit method would be. • It exhibits the simplicity of implementation of an explicit method. • It is specifically designed for slow transient flow problems of long duration such as can occur inside nuclear reactor coolant systems. • Our findings indicate the new method can integrate slow transient problems very efficiently; and its implementation is very robust. - Abstract: We introduce a point implicit time integration technique for slow transient flow problems. The method treats the solution variables of interest (that can be located at cell centers, cell edges, or cell nodes) implicitly and the rest of the information related to same or other variables are handled explicitly. The method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods, except it involves a few additional function(s) evaluation steps. Moreover, the method is unconditionally stable, as a fully implicit method would be. This new approach exhibits the simplicity of implementation of explicit methods and the stability of implicit methods. It is specifically designed for slow transient flow problems of long duration wherein one would like to perform time integrations with very large time steps. Because the method can be time inaccurate for fast transient problems, particularly with larger time steps, an appropriate solution strategy for a problem that evolves from a fast to a slow transient would be to integrate the fast transient with an explicit or semi-implicit technique and then switch to this point implicit method as soon as the time variation slows sufficiently. We have solved several test problems that result from scalar or systems of flow equations. Our findings indicate the new method can integrate slow transient problems very

  16. A point implicit time integration technique for slow transient flow problems

    International Nuclear Information System (INIS)

    Kadioglu, Samet Y.; Berry, Ray A.; Martineau, Richard C.

    2015-01-01

    Highlights: • This new method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods. • It is unconditionally stable, as a fully implicit method would be. • It exhibits the simplicity of implementation of an explicit method. • It is specifically designed for slow transient flow problems of long duration such as can occur inside nuclear reactor coolant systems. • Our findings indicate the new method can integrate slow transient problems very efficiently; and its implementation is very robust. - Abstract: We introduce a point implicit time integration technique for slow transient flow problems. The method treats the solution variables of interest (that can be located at cell centers, cell edges, or cell nodes) implicitly and the rest of the information related to same or other variables are handled explicitly. The method does not require implicit iteration; instead it time advances the solutions in a similar spirit to explicit methods, except it involves a few additional function(s) evaluation steps. Moreover, the method is unconditionally stable, as a fully implicit method would be. This new approach exhibits the simplicity of implementation of explicit methods and the stability of implicit methods. It is specifically designed for slow transient flow problems of long duration wherein one would like to perform time integrations with very large time steps. Because the method can be time inaccurate for fast transient problems, particularly with larger time steps, an appropriate solution strategy for a problem that evolves from a fast to a slow transient would be to integrate the fast transient with an explicit or semi-implicit technique and then switch to this point implicit method as soon as the time variation slows sufficiently. We have solved several test problems that result from scalar or systems of flow equations. Our findings indicate the new method can integrate slow transient problems very

  17. A hybrid superconducting fault current limiter for enhancing transient stability in Korean power systems

    Science.gov (United States)

    Seo, Sangsoo; Kim, Seog-Joo; Moon, Young-Hwan; Lee, Byongjun

    2013-11-01

    Additional power generation sites have been limited in Korea, despite the fact load demands are gradually increasing. In order to meet these increasing demands, Korea’s power system company has begun constructing new generators at existing sites. Thus, multi-unit plants can create problems in terms of transient stability when a large disturbance occurs. This paper proposes a hybrid superconducting fault current limiter (SFCL) application to enhance the transient stability of multi-unit power plants. SFCLs reduce fault currents, and limitation currents decrease the imbalance of the mechanical and electrical torque of the generators, resulting in an improvement in transient stability.

  18. An improved direct feedback linearization technique for transient stability enhancement and voltage regulation of power generators

    Energy Technology Data Exchange (ETDEWEB)

    Kenne, Godpromesse [Laboratoire d' Automatique et d' Informatique Appliquee (LAIA), Departement de Genie Electrique, Universite de Dschang, B.P. 134 Bandjoun, Cameroun; Goma, Raphael; Lamnabhi-Lagarrigue, Francoise [Laboratoire des Signaux et Systemes (L2S), CNRS-SUPELEC, Universite Paris XI, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France); Nkwawo, Homere [Departement GEII, Universite Paris XIII, IUT Villetaneuse, 99 Avenue Jean Baptiste Clement, 93430 Villetaneuse (France); Arzande, Amir; Vannier, Jean Claude [Departement Energie, Ecole Superieure d' Electricite-SUPELEC, 3 Rue Joliot Curie, 91192 Gif-sur-Yvette (France)

    2010-09-15

    In this paper, a simple improved direct feedback linearization design method for transient stability and voltage regulation of power systems is discussed. Starting with the classical direct feedback linearization technique currently applied to power systems, an adaptive nonlinear excitation control of synchronous generators is proposed, which is new and effective for engineering. The power angle and mechanical power input are not assumed to be available. The proposed method is based on a standard third-order model of a synchronous generator which requires only information about the physical available measurements of angular speed, active electric power and generator terminal voltage. Experimental results of a practical power system show that fast response, robustness, damping, steady-state and transient stability as well as voltage regulation are all achieved satisfactorily. (author)

  19. Comparative Study of Time-Frequency Decomposition Techniques for Fault Detection in Induction Motors Using Vibration Analysis during Startup Transient

    Directory of Open Access Journals (Sweden)

    Paulo Antonio Delgado-Arredondo

    2015-01-01

    Full Text Available Induction motors are critical components for most industries and the condition monitoring has become necessary to detect faults. There are several techniques for fault diagnosis of induction motors and analyzing the startup transient vibration signals is not as widely used as other techniques like motor current signature analysis. Vibration analysis gives a fault diagnosis focused on the location of spectral components associated with faults. Therefore, this paper presents a comparative study of different time-frequency analysis methodologies that can be used for detecting faults in induction motors analyzing vibration signals during the startup transient. The studied methodologies are the time-frequency distribution of Gabor (TFDG, the time-frequency Morlet scalogram (TFMS, multiple signal classification (MUSIC, and fast Fourier transform (FFT. The analyzed vibration signals are one broken rotor bar, two broken bars, unbalance, and bearing defects. The obtained results have shown the feasibility of detecting faults in induction motors using the time-frequency spectral analysis applied to vibration signals, and the proposed methodology is applicable when it does not have current signals and only has vibration signals. Also, the methodology has applications in motors that are not fed directly to the supply line, in such cases the analysis of current signals is not recommended due to poor current signal quality.

  20. Dark properties and transient current response of Si0.95Ge0.05 n+p devices

    International Nuclear Information System (INIS)

    Ruzin, Arie; Marunko, S.; Abrosimov, N.V.; Riemann, H.

    2004-01-01

    In this study we present the dark properties of 'pin' devices fabricated with Czochralski grown Si 0.95 Ge 0.05 bulk single crystals. The growth of such material is most challenging because of the constitutional supercooling effect. The potential advantages of Si 1-x Ge x to be used for X- and gamma-ray detection applications are overviewed. At room temperature the generation current in the devices is too high for spectroscopy applications, but enables transient current technique (TCT) measurements. The current however drops significantly with moderate cooling. The effective majority carrier concentration is shown to be ∼2x10 14 cm -3 , and hole mobility ∼320 cm 2 /V s

  1. Approximative calculation of transient short-circuit currents in power-systems

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, K; Rosenberger, R; Dettmann, K D; Kegel, R

    1986-08-01

    The paper shows that it is approximatively possible to calculate the transient short-circuit currents for symmetrical and asymmetrical faults in power-systems. For that purpose a simple equivalent network is found. Its error of approximation is small. For the important maximum short-circuit current limits of error are pointed out compared to VDE 0102.

  2. Transient current in a quantum dot subject to a change in coupling to its leads

    International Nuclear Information System (INIS)

    Izmaylov, A F; Goker, A; Friedman, B A; Nordlander, P

    2006-01-01

    The time-dependent non-crossing approximation is used to calculate the transient currents through a quantum dot in the Kondo regime subject to a sudden change in its coupling to the leads. The currents are found to display transient non-universal behaviour immediately after the perturbation and then to follow a slow universal increase toward equilibrium. The timescales for the approach to equilibrium are shown to be the same as those recently identified in a study of transient currents in a quantum dot subject to a sudden change in the energy of the dot level (Plihal et al 2005 Phys. Rev. B 71 165321). We present improved numerical algorithms which enable relatively fast calculation of the transient response of quantum dots to sudden perturbations

  3. Evaluation of the Transient Eddy Current Potential Drop of a Four Point Probe

    Science.gov (United States)

    Bowler, J. R.

    2009-03-01

    The transient electrical potential drop of a four point probe has been calculated for the case where a current pulse is injected into a conductive plate via two surface contact electrodes and the voltage measured between two other contact electrodes. The four contact points can be co-linear but this is not always case. For example, they can form a rectangle. Usually such probes carry direct current or alternating current and are used to measure electrical conductivity, crack dimensions or variations of conductivity and magnetic permeability with depth. However, the advantage of a current pulse excitation is that information on the variations of material properties with depth can be acquired rapidly and conveniently. What is needed is a means to infer material properties such as the conductivity variations with depth from the transient field measurements. Here, as an initial step in developing this analysis, we report on the evaluation of transient potential drop signals for four point probes on a homogeneous conductive plates.

  4. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A.; Laird, J.S.; Bardos, R.A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T.; Sekiguchi, H. [Electrotechnical Laboratory, Tsukuba (Japan).

    1993-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  5. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A; Laird, J S; Bardos, R A; Legge, G J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T; Sekiguchi, H [Electrotechnical Laboratory, Tsukuba (Japan).

    1994-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  6. A fast transient response low dropout regulator with current control methodology

    Energy Technology Data Exchange (ETDEWEB)

    Ma Zhuo; Guo Yang; Duan Zhikui; Xie Lunguo; Chen Jihua; Yu Jinshan, E-mail: guoyang@nudt.edu.cn [School of Computer, National University of Defense Technology, Changsha 410073 (China)

    2011-08-15

    A transient performance optimized CCL-LDO regulator is proposed. In the CCL-LDO, the control method of the charge pump phase-locked loop is adopted. A current control loop has the feedback signal and reference current to be compared, and then a loop filter generates the gate voltage of the power MOSFET by integrating the error current. The CCL-LDO has the optimized damping coefficient and natural resonant frequency, while its output voltage can be sub-1-V and is not restricted by the reference voltage. With a 1 {mu}F decoupling capacitor, the experimental results based on a 0.13 {mu}m CMOS process show that the output voltage is 1.0 V; when the workload changes from 100 {mu}A to 100 mA transiently, the stable dropout is 4.25 mV, the settling time is 8.2 {mu}s and the undershoot is 5.11 mV; when the workload changes from 100 mA to 100 {mu}A transiently, the stable dropout is 4.25 mV, the settling time is 23.3 {mu}s and the overshoot is 6.21 mV. The PSRR value is more than -95 dB. Most of the attributes of the CCL-LDO are improved rapidly with a FOM value of 0.0097.

  7. A fast transient response low dropout regulator with current control methodology

    International Nuclear Information System (INIS)

    Ma Zhuo; Guo Yang; Duan Zhikui; Xie Lunguo; Chen Jihua; Yu Jinshan

    2011-01-01

    A transient performance optimized CCL-LDO regulator is proposed. In the CCL-LDO, the control method of the charge pump phase-locked loop is adopted. A current control loop has the feedback signal and reference current to be compared, and then a loop filter generates the gate voltage of the power MOSFET by integrating the error current. The CCL-LDO has the optimized damping coefficient and natural resonant frequency, while its output voltage can be sub-1-V and is not restricted by the reference voltage. With a 1 μF decoupling capacitor, the experimental results based on a 0.13 μm CMOS process show that the output voltage is 1.0 V; when the workload changes from 100 μA to 100 mA transiently, the stable dropout is 4.25 mV, the settling time is 8.2 μs and the undershoot is 5.11 mV; when the workload changes from 100 mA to 100 μA transiently, the stable dropout is 4.25 mV, the settling time is 23.3 μs and the overshoot is 6.21 mV. The PSRR value is more than -95 dB. Most of the attributes of the CCL-LDO are improved rapidly with a FOM value of 0.0097.

  8. Profiling of Current Transients in Capacitor Type Diamond Sensors

    Science.gov (United States)

    Gaubas, Eugenijus; Ceponis, Tomas; Meskauskaite, Dovile; Kazuchits, Nikolai

    2015-01-01

    The operational characteristics of capacitor-type detectors based on HPHT and CVD diamond have been investigated using perpendicular and parallel injection of carrier domain regimes. Simulations of the drift-diffusion current transients have been implemented by using dynamic models based on Shockley-Ramo’s theorem, under injection of localized surface domains and of bulk charge carriers. The bipolar drift-diffusion regimes have been analyzed for the photo-induced bulk domain (packet) of excess carriers. The surface charge formation and polarization effects dependent on detector biasing voltage have been revealed. The screening effects ascribed to surface charge and to dynamics of extraction of the injected bulk excess carrier domain have been separated and explained. The parameters of drift mobility of the electrons μe = 4000 cm2/Vs and holes μh = 3800 cm2/Vs have been evaluated for CVD diamond using the perpendicular profiling of currents. The coefficient of carrier ambipolar diffusion Da = 97 cm2/s and the carrier recombination lifetime τR,CVD ≌ 110 ns in CVD diamond were extracted by combining analysis of the transients of the sensor current and the microwave probed photoconductivity. The carrier trapping with inherent lifetime τR,HPHT ≌ 2 ns prevails in HPHT diamond. PMID:26061200

  9. Heavy Ion Microbeam- and Broadbeam-Induced Current Transients in SiGe HBTs

    Science.gov (United States)

    Pellish, Jonathan A.; Reed, R. A.; McMorrow, D.; Vizkelethy, G.; Ferlet-Cavrois, V.; Baggio, J.; Duhamel, O.; Moen, K. A.; Phillips, S. D.; Diestelhorst, R. M.; hide

    2009-01-01

    IBM 5AM SiGe HBT is device-under-test. High-speed measurement setup. Low-impedance current transient measurements. SNL, JYFL, GANIL. Microbeam to broadbeam position inference. Improvement to state-of-the-art. Microbeam (SNL) transients reveal position dependent heavy ion response, Unique response for different device regions Unique response for different bias schemes. Similarities to TPA pulsed-laser data. Broadbeam transients (JYFL and GANIL) provide realistic heavy ion response. Feedback using microbeam data. Overcome issues of LET and ion range with microbeam. **Angled Ar-40 data in full paper. Data sets yield first-order results, suitable for TCAD calibration feedback.

  10. A 3 A sink/source current fast transient response low-dropout Gm driven linear regulator

    International Nuclear Information System (INIS)

    Chu Xiuqin; Li Qingwei; Lai Xinquan; Yuan Bing; Li Yanming; Zhao Yongrui

    2011-01-01

    A 3 A sink/source G m -driven CMOS low-dropout regulator (LDO), specially designed for low input voltage and low cost, is presented by utilizing the structure of a current mirror G m (transconductance) driving technique, which provides high stability as well as a fast load transient response. The proposed LDO was fabricated by a 0.5 μm standard CMOS process, and the die size is as small as 1.0 mm 2 . The proposed LDO dissipates 220 μA of quiescent current in no-load conditions and is able to deliver up to 3 A of load current. The measured results show that the output voltage can be resumed within 2 μs with a less than 1 mV overshoot and undershoot in the output current step from -1.8 to 1.8 A with a 0.1 μs rising and falling time at three 10 μF ceramic capacitors. (semiconductor integrated circuits)

  11. Transient data acquisition techniques under EDS

    International Nuclear Information System (INIS)

    Telford, S.

    1985-06-01

    This paper is the first of a series which describes the Enrichment Diagnostic System (EDS) developed for the MARS project at Lawrence Livermore National Laboratory. Although EDS was developed for use on AVLIS, the functional requirements, overall design, and specific techniques are applicable to any experimental data acquisition system involving large quantities of transient data. In particular this paper will discuss the techniques and equipment used to do the data acquisition. Included are what types of hardware are used and how that hardware (CAMAC, digital oscilloscopes) is interfaced to the HP computers. In this discussion the author will address the problems encountered and the solutions used, as well as the performance of the instrument/computer interfaces. The second topic the author will discuss is how the acquired data is associated to graphics and analysis portions of EDS through efficient real time data bases. This discussion will include how the acquired data is folded into the overall structure of EDS providing the user immediate access to raw and analyzed data. By example you will see how easily a new diagnostic can be added to the EDS structure without modifying the other parts of the system. 8 figs

  12. Positron beam studies of transients in semiconductors

    International Nuclear Information System (INIS)

    Beling, C.D.; Ling, C.C.; Cheung, C.K.; Naik, P.S.; Zhang, J.D.; Fung, S.

    2006-01-01

    Vacancy-sensing positron deep level transient spectroscopy (PDLTS) is a positron beam-based technique that seeks to provide information on the electronic ionization levels of vacancy defects probed by the positron through the monitoring of thermal transients. The experimental discoveries leading to the concept of vacancy-sensing PDLTS are first reviewed. The major problem associated with this technique is discussed, namely the strong electric fields establish in the near surface region of the sample during the thermal transient which tend to sweep positrons into the contact with negligible defect trapping. New simulations are presented which suggest that under certain conditions a sufficient fraction of positrons may be trapped into ionizing defects rendering PDLTS technique workable. Some suggestions are made for techniques that might avoid the problematic electric field problem, such as optical-PDLTS where deep levels are populated using light and the use of high forward bias currents for trap filling

  13. Scanning ion deep level transient spectroscopy: I. Theory

    International Nuclear Information System (INIS)

    Laird, J S; Jagadish, C; Jamieson, D N; Legge, G J F

    2006-01-01

    Theoretical aspects of a new technique for the MeV ion microbeam are described in detail for the first time. The basis of the technique, termed scanning ion deep level transient spectroscopy (SIDLTS), is the imaging of defect distributions within semiconductor devices. The principles of SIDLTS are similar to those behind other deep level transient spectroscopy (DLTS) techniques with the main difference stemming from the injection of carriers into traps using the localized energy-loss of a focused MeV ion beam. Energy-loss of an MeV ion generates an electron-hole pair plasma, providing the equivalent of a DLTS trap filling pulse with a duration which depends on space-charge screening of the applied electric field and ambipolar erosion of the plasma for short ranging ions. Some nanoseconds later, the detrapping current transient is monitored as a charge transient. Scanning the beam in conjunction with transient analysis allows the imaging of defect levels. As with DLTS, the temperature dependence of the transient can be used to extract trap activation levels. In this, the first of a two-part paper, we introduce the various stages of corner capture and derive a simple expression for the observed charge transient. The second paper will illustrate the technique on a MeV ion implanted Au-Si Schottky junction

  14. Analysis of transient state in HTS tapes under ripple DC load current

    Science.gov (United States)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  15. Modeling of environmentally induced transients within satellites

    Science.gov (United States)

    Stevens, N. John; Barbay, Gordon J.; Jones, Michael R.; Viswanathan, R.

    1987-01-01

    A technique is described that allows an estimation of possible spacecraft charging hazards. This technique, called SCREENS (spacecraft response to environments of space), utilizes the NASA charging analyzer program (NASCAP) to estimate the electrical stress locations and the charge stored in the dielectric coatings due to spacecraft encounter with a geomagnetic substorm environment. This information can then be used to determine the response of the spacecraft electrical system to a surface discharge by means of lumped element models. The coupling into the electronics is assumed to be due to magnetic linkage from the transient currents flowing as a result of the discharge transient. The behavior of a spinning spacecraft encountering a severe substorm is predicted using this technique. It is found that systems are potentially vulnerable to upset if transient signals enter through the ground lines.

  16. A Effect discussion of transient electromagnetic sounding technique in paleochannel-type sandstone-hosted uranium deposit

    International Nuclear Information System (INIS)

    Yang Jianchun; Fang Genxian; Yang Yaxin

    2003-01-01

    On the base of the application of transient electromagnetic technique of paleochannel-type sandstone-hosted uranium deposits in Tengchong region of Yunan Province, this paper analyses the detect example. It discusses the theory foundation of TEM, fieldwork means, data processing and interpret. By contrast with routine electricity farad, the transient electromagnetic technique have the special merit and favorable space resolve gender under conditions of intricacy terrain. This means can get good effect in detecting paleochannel-type sandstone-hosted uranium deposits space position. It is a good reference for other prospecting and exploration work

  17. Transient recovery voltage analysis for various current breaking mathematical models: shunt reactor and capacitor bank de-energization study

    Directory of Open Access Journals (Sweden)

    Oramus Piotr

    2015-09-01

    Full Text Available Electric arc is a complex phenomenon occurring during the current interruption process in the power system. Therefore performing digital simulations is often necessary to analyse transient conditions in power system during switching operations. This paper deals with the electric arc modelling and its implementation in simulation software for transient analyses during switching conditions in power system. Cassie, Cassie-Mayr as well as Schwarz-Avdonin equations describing the behaviour of the electric arc during the current interruption process have been implemented in EMTP-ATP simulation software and presented in this paper. The models developed have been used for transient simulations to analyse impact of the particular model and its parameters on Transient Recovery Voltage in different switching scenarios: during shunt reactor switching-off as well as during capacitor bank current switching-off. The selected simulation cases represent typical practical scenarios for inductive and capacitive currents breaking, respectively.

  18. Simulation of the transient eddy current measurement for the characterization of depth and conductivity of a plate

    International Nuclear Information System (INIS)

    Cheng, Weiying; Komura, Ichiro

    2008-01-01

    A transient eddy current measurement method is presented to determine the thickness and conductivity of a conductive plate. The conductive plate is induced by an air-cored coil, the magnetic flux density along the axial is measured and the various signals corresponding to plates with different thickness and conductivity are calculated using a 3D transient eddy current simulator. Characteristic features are obtained from the transient response. A similarity-based modeling method is utilized in this study to estimate the thickness and conductivity of the conductive plate. (author)

  19. Origin of switching current transients in TIPS-pentacene based organic thin-film transistor with polymer dielectric

    Science.gov (United States)

    Singh, Subhash; Mohapatra, Y. N.

    2017-06-01

    We have investigated switch-on drain-source current transients in fully solution-processed thin film transistors based on 6,13-bis(triisopropylsilylethynyl) pentacene (TIPS-pentacene) using cross-linked poly-4-vinylphenol as a dielectric. We show that the nature of the transient (increasing or decreasing) depends on both the temperature and the amplitude of the switching pulse at the gate. The isothermal transients are analyzed spectroscopically in a time domain to extract the degree of non-exponentiality and its possible origin in trap kinetics. We propose a phenomenological model in which the exchange of electrons between interfacial ions and traps controls the nature of the drain current transients dictated by the Fermi level position. The origin of interfacial ions is attributed to the essential fabrication step of UV-ozone treatment of the dielectric prior to semiconductor deposition.

  20. Visualizing the transient electroosmotic flow and measuring the zeta potential of microchannels with a micro-PIV technique.

    Science.gov (United States)

    Yan, Deguang; Nguyen, Nam-Trung; Yang, Chun; Huang, Xiaoyang

    2006-01-14

    We have demonstrated a transient micro particle image velocimetry (micro-PIV) technique to measure the temporal development of electroosmotic flow in microchannels. Synchronization of different trigger signals for the laser, the CCD camera, and the high-voltage switch makes this measurement possible with a conventional micro-PIV setup. Using the transient micro-PIV technique, we have further proposed a method on the basis of inertial decoupling between the particle electrophoretic motion and the fluid electroosmotic flow to determine the electrophoretic component in the particle velocity and the zeta potential of the channel wall. It is shown that using the measured zeta potentials, the theoretical predictions agree well with the transient response of the electroosmotic velocities measured in this work.

  1. A 3 A sink/source current fast transient response low-dropout G{sub m} driven linear regulator

    Energy Technology Data Exchange (ETDEWEB)

    Chu Xiuqin; Li Qingwei; Lai Xinquan; Yuan Bing [Institute of Electronic CAD, Xidian University, Xi' an 710071 (China); Li Yanming [School of Electronic and Control Engineering, Chang' an University, Xi' an 710064 (China); Zhao Yongrui, E-mail: liqw309@163.com, E-mail: xqchu@mail.xidian.edu.cn [Key Laboratory of High-Speed Circuit Design and EMC, Ministry of Education, Xidian University, Xi' an 710071 (China)

    2011-06-15

    A 3 A sink/source G{sub m}-driven CMOS low-dropout regulator (LDO), specially designed for low input voltage and low cost, is presented by utilizing the structure of a current mirror G{sub m} (transconductance) driving technique, which provides high stability as well as a fast load transient response. The proposed LDO was fabricated by a 0.5 {mu}m standard CMOS process, and the die size is as small as 1.0 mm{sup 2}. The proposed LDO dissipates 220 {mu}A of quiescent current in no-load conditions and is able to deliver up to 3 A of load current. The measured results show that the output voltage can be resumed within 2 {mu}s with a less than 1 mV overshoot and undershoot in the output current step from -1.8 to 1.8 A with a 0.1 {mu}s rising and falling time at three 10 {mu}F ceramic capacitors. (semiconductor integrated circuits)

  2. Effects of transient bottom water currents and oxygen concentrations on benthic exchange rates as assessed by eddy correlation measurements

    DEFF Research Database (Denmark)

    Holtappels, Moritz; Glud, Ronnie N.; Doris, Daphne

    2013-01-01

    Eddy correlation (EC) measurements in the benthic boundary layer (BBL) allow estimating benthic O2 uptake from a point distant to the sediment surface. This noninvasive approach has clear advantages as it does not disturb natural hydrodynamic conditions, integrates the flux over a large foot-print...... area and allows many repetitive flux measurements. A drawback is, however, that the measured flux in the bottom water is not necessarily equal to the flux across the sediment-water interface. A fundamental assumption of the EC technique is that mean current velocities and mean O2 concentrations...... in the bottom water are in steady state, which is seldom the case in highly dynamic environments like coastal waters. Therefore, it is of great importance to estimate the error introduced by nonsteady state conditions. We investigated two cases of transient conditions. First, the case of transient O2...

  3. Use of time space Green's functions in the computation of transient eddy current fields

    International Nuclear Information System (INIS)

    Davey, K.; Turner, L.

    1988-01-01

    The utility of integral equations to solve eddy current problems has been borne out by numerous computations in the past few years, principally in sinusoidal steady-state problems. This paper attempts to examine the applicability of the integral approaches in both time and space for the more generic transient problem. The basic formulation for the time space Green's function approach is laid out. A technique employing Gauss-Laguerre integration is employed to realize the temporal solution, while Gauss--Legendre integration is used to resolve the spatial field character. The technique is then applied to the fusion electromagnetic induction experiments (FELIX) cylinder experiments in both two and three dimensions. It is found that quite accurate solutions can be obtained using rather coarse time steps and very few unknowns; the three-dimensional field solution worked out in this context used basically only four unknowns. The solution appears to be somewhat sensitive to the choice of time step, a consequence of a numerical instability imbedded in the Green's function near the origin

  4. Technique for selection of transient radiation-hard junction-isolated integrated circuits

    International Nuclear Information System (INIS)

    Crowley, J.L.; Junga, F.A.; Stultz, T.J.

    1976-01-01

    A technique is presented which demonstrates the feasibility of selecting junction-isolated integrated circuits (JI/ICS) for use in transient radiation environments. The procedure guarantees that all PNPN paths within the integrated circuit are identified and describes the methods used to determine whether the paths represent latchup susceptible structures. Two examples of the latchup analysis are given involving an SSI and an LSI bipolar junction-isolated integrated circuit

  5. Modelling the transient behaviour of pulsed current tungsten-inert-gas weldpools

    Science.gov (United States)

    Wu, C. S.; Zheng, W.; Wu, L.

    1999-01-01

    A three-dimensional model is established to simulate the pulsed current tungsten-inert-gas (TIG) welding process. The goal is to analyse the cyclic variation of fluid flow and heat transfer in weldpools under periodic arc heat input. To this end, an algorithm, which is capable of handling the transience, nonlinearity, multiphase and strong coupling encountered in this work, is developed. The numerical simulations demonstrate the transient behaviour of weldpools under pulsed current. Experimental data are compared with numerical results to show the effectiveness of the developed model.

  6. Theory of potentiostatic current transients for coupled catalytic reaction at random corrugated fractal electrode

    International Nuclear Information System (INIS)

    Jha, Shailendra K.; Kant, Rama

    2010-01-01

    We developed a mathematical model for the first order homogeneous catalytic chemical reaction coupled with an electron transfer (EC') on a rough working electrode. Results are obtained for the various roughness models of electrode corrugations, viz., (i) roughness as an exact periodic function, (ii) roughness as a random function with known statistical properties, and (iii) roughness as a random function with statistical self-affine fractality over a finite range of length scales. Method of Green's function is used in the formulation to obtain second-order perturbation (in roughness profile) expressions for the concentration, the local current density and the current transients. A general operator structure between these quantities and arbitrary roughness profile is emphasized. The statistically averaged (randomly rough) electrode response is obtained by an ensemble averaging over all possible surface configurations. An elegant mathematical formula between the average electrochemical current transient and surface structure factor or power-spectrum of roughness is obtained. This formula is used to obtain an explicit equation for the current on an approximately self-affine (or realistic) fractal electrode with a limited range of length scales of irregularities. This description of realistic fractal is obtained by cutoff power law power-spectrum of roughness. The realistic fractal power-spectrum consists of four physical characteristics, viz., the fractal dimension (D H ), lower (l) and upper (L) cutoff length scales of fractality and a proportionality factor (μ), which is related to the topothesy or strength of fractality. Numerical calculations are performed on final results to understand the effect of catalytic reaction and fractal morphological characteristics on potentiostatic current transients.

  7. Design Improvements on Graded Insulation of Power Transformers Using Transient Electric Field Analysis and Visualization Technique

    OpenAIRE

    Yamashita, Hideo; Nakamae, Eihachiro; Namera, Akihiro; Cingoski, Vlatko; Kitamura, Hideo

    1998-01-01

    This paper deals with design improvements on graded insulation of power transformers using transient electric field analysis and a visualization technique. The calculation method for transient electric field analysis inside a power transformer impressed with impulse voltage is presented: Initially, the concentrated electric network for the power transformer is concentrated by dividing transformer windings into several blocks and by computing the electric circuit parameters.

  8. Direct time-domain techniques for transient radiation and scattering

    International Nuclear Information System (INIS)

    Miller, E.K.; Landt, J.A.

    1976-01-01

    A tutorial introduction to transient electromagnetics, focusing on direct time-domain techniques, is presented. Physical, mathematical, numerical, and experimental aspects of time-domain methods, with emphasis on wire objects excited as antennas or scatters are examined. Numerous computed examples illustrate the characteristics of direct time-domain procedures, especially where they may offer advantages over procedures in the more familiar frequency domain. These advantages include greater solution efficiency for many types of problems, the ability to handle nonlinearities, improved physical insight and interpretability, availability of wide-band information from a single calculation, and the possibility of isolating interactions among various parts of an object using time-range gating

  9. Computation of transient 3-D eddy current in nonmagnetic conductor

    International Nuclear Information System (INIS)

    Yeh, H.T.

    1978-01-01

    A numerical procedure was developed to solve transient three-dimensional (3-D) eddy current problems for nonmagnetic conductor. Integral equation formulation in terms of vector potential is used to simplify the matching of boundary conditions. The resulting equations and their numerical approximation were shown to be singular and to require special handling. Several types of symmetries were introduced. They not only reduce the number of algebraic equations to be solved, but also modify the nature of the equations and render them nonsingular. Temporal behavior was obtained with the Runge-Kutta method. The program is tested in several examples of eddy currents for its spatial and temporal profiles, shielding, boundary surface effects, and application of various symmetry options

  10. Influence of wavelength on transient short-circuit current in polycrystalline silicon solar cells

    International Nuclear Information System (INIS)

    Ba, B.; Kane, M.

    1993-10-01

    The influence of the wavelength of a monochromatic illumination on transient short-circuit current in an n/p polycrystalline silicon part solar cell junction is investigated. A wavelength dependence in the initial part of the current decay is observed in the case of cells with moderate grain boundary effects. This influence is attenuated in polycrystalline cells with strong grain boundary activity. (author). 10 refs, 6 figs

  11. Current and anticipated use of thermal-hydraulic codes for BWR transient and accident analyses in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Kenji; Ebata, Shigeo [Toshiba Corp., Yokohama (Japan)

    1997-07-01

    This paper summarizes the current and anticipated use of the thermal-hydraulic and neutronic codes for the BWR transient and accident analyses in Japan. The codes may be categorized into the licensing codes and the best estimate codes for the BWR transient and accident analyses. Most of the licensing codes have been originally developed by General Electric. Some codes have been updated based on the technical knowledge obtained in the thermal hydraulic study in Japan, and according to the BWR design changes. The best estimates codes have been used to support the licensing calculations and to obtain the phenomenological understanding of the thermal hydraulic phenomena during a BWR transient or accident. The best estimate codes can be also applied to a design study for a next generation BWR to which the current licensing model may not be directly applied. In order to rationalize the margin included in the current BWR design and develop a next generation reactor with appropriate design margin, it will be required to improve the accuracy of the thermal-hydraulic and neutronic model. In addition, regarding the current best estimate codes, the improvement in the user interface and the numerics will be needed.

  12. Transient global amnesia: current perspectives

    Directory of Open Access Journals (Sweden)

    Spiegel DR

    2017-10-01

    Full Text Available David R Spiegel, Justin Smith, Ryan R Wade, Nithya Cherukuru, Aneel Ursani, Yuliya Dobruskina, Taylor Crist, Robert F Busch, Rahim M Dhanani, Nicholas Dreyer Department of Psychiatry and Behavioral Sciences, Eastern Virginia Medical School, Norfolk, VA, USA Abstract: Transient global amnesia (TGA is a clinical syndrome characterized by the sudden onset of an extraordinarily large reduction of anterograde and a somewhat milder reduction of retrograde episodic long-term memory. Additionally, executive functions are described as diminished. Although it is suggested that various factors, such as migraine, focal ischemia, venous flow abnormalities, and epileptic phenomena, are involved in the pathophysiology and differential diagnosis of TGA, the factors triggering the emergence of these lesions are still elusive. Recent data suggest that the vulnerability of CA1 neurons to metabolic stress plays a pivotal part in the pathophysiological cascade, leading to an impairment of hippocampal function during TGA. In this review, we discuss clinical aspects, new imaging findings, and recent clinical–epidemiological data with regard to the phenotype, functional anatomy, and putative cellular mechanisms of TGA. Keywords: transient global amnesia, vascular, migraines, psychiatric

  13. Adaptive polynomial chaos techniques for uncertainty quantification of a gas cooled fast reactor transient

    International Nuclear Information System (INIS)

    Perko, Z.; Gilli, L.; Lathouwers, D.; Kloosterman, J. L.

    2013-01-01

    Uncertainty quantification plays an increasingly important role in the nuclear community, especially with the rise of Best Estimate Plus Uncertainty methodologies. Sensitivity analysis, surrogate models, Monte Carlo sampling and several other techniques can be used to propagate input uncertainties. In recent years however polynomial chaos expansion has become a popular alternative providing high accuracy at affordable computational cost. This paper presents such polynomial chaos (PC) methods using adaptive sparse grids and adaptive basis set construction, together with an application to a Gas Cooled Fast Reactor transient. Comparison is made between a new sparse grid algorithm and the traditionally used technique proposed by Gerstner. An adaptive basis construction method is also introduced and is proved to be advantageous both from an accuracy and a computational point of view. As a demonstration the uncertainty quantification of a 50% loss of flow transient in the GFR2400 Gas Cooled Fast Reactor design was performed using the CATHARE code system. The results are compared to direct Monte Carlo sampling and show the superior convergence and high accuracy of the polynomial chaos expansion. Since PC techniques are easy to implement, they can offer an attractive alternative to traditional techniques for the uncertainty quantification of large scale problems. (authors)

  14. Application of positron annihilation lifetime technique to the study of deep level transients in semiconductors

    Science.gov (United States)

    Deng, A. H.; Shan, Y. Y.; Fung, S.; Beling, C. D.

    2002-03-01

    Unlike its conventional applications in lattice defect characterization, positron annihilation lifetime technique was applied to study temperature-dependent deep level transients in semiconductors. Defect levels in the band gap can be determined as they are determined by conventional deep level transient spectroscopy (DLTS) studies. The promising advantage of this application of positron annihilation over the conventional DLTS is that it could further extract extra microstructure information of deep-level defects, such as whether a deep level defect is vacancy related or not. A demonstration of EL2 defect level transient study in GaAs was shown and the EL2 level of 0.82±0.02 eV was obtained by a standard Arrhenius analysis, similar to that in conventional DLTS studies.

  15. Fast transient current response to switching events in short chains of molecular islands

    Czech Academy of Sciences Publication Activity Database

    Kalvová, Anděla; Špička, Václav; Velický, B.

    2013-01-01

    Roč. 26, č. 4 (2013), s. 773-777 ISSN 1557-1939 R&D Projects: GA ČR GAP204/12/0897 Institutional support: RVO:68378271 Keywords : nonequilibrium * molecular islands * initial correlations * transient currents Subject RIV: BE - Theoretical Physics Impact factor: 0.930, year: 2013

  16. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    International Nuclear Information System (INIS)

    Prasser, H.M.

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  17. Limitations of transient power loads on DEMO and analysis of mitigation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Maviglia, F., E-mail: francesco.maviglia@euro-fusion.org [EUROfusion Consortium, PPPT Department, Boltzmannstr. 2, Garching (Germany); Consorzio CREATE, University Napoli Federico II – DIETI, 80125 Napoli (Italy); Federici, G. [EUROfusion Consortium, PPPT Department, Boltzmannstr. 2, Garching (Germany); Strohmayer, G. [Max-Planck-Institut fur Plasmaphysik, Boltzmannstr. 2, Garching (Germany); Wenninger, R. [EUROfusion Consortium, PPPT Department, Boltzmannstr. 2, Garching (Germany); Max-Planck-Institut fur Plasmaphysik, Boltzmannstr. 2, Garching (Germany); Bachmann, C. [EUROfusion Consortium, PPPT Department, Boltzmannstr. 2, Garching (Germany); Albanese, R. [Consorzio CREATE, University Napoli Federico II – DIETI, 80125 Napoli (Italy); Ambrosino, R. [Consorzio CREATE University Napoli Parthenope, Naples (Italy); Li, M. [Max-Planck-Institut fur Plasmaphysik, Boltzmannstr. 2, Garching (Germany); Loschiavo, V.P. [Consorzio CREATE, University Napoli Federico II – DIETI, 80125 Napoli (Italy); You, J.H. [Max-Planck-Institut fur Plasmaphysik, Boltzmannstr. 2, Garching (Germany); Zani, L. [CEA, IRFM, F-13108 St Paul-Lez-Durance (France)

    2016-11-01

    Highlights: • A parametric thermo-hydraulic analysis of the candidate DEMO divertor is presented. • The operational space assessment is presented under static and transient heat loads. • Strike points sweeping is analyzed as a divertor power exhaust mitigation technique. • Results are presented on sweeping installed power required, AC losses and thermal fatigue. - Abstract: The present European standard DEMO divertor target technology is based on a water-cooled tungsten mono-block with a copper alloy heat sink. This paper presents the assessment of the operational space of this technology under static and transient heat loads. A transient thermo-hydraulic analysis was performed using the code RACLETTE, which allowed a broad parametric scan of the target geometry and coolant conditions. The limiting factors considered were the coolant critical heat flux (CHF), and the temperature limits of the materials. The second part of the work is devoted to the study of the plasma strike point sweeping as a mitigation technique for the divertor power exhaust. The RACLETTE code was used to evaluate the impact of a large range of sweeping frequencies and amplitudes. A reduced subset of cases, which complied with the constraints, was benchmarked with a 3D FEM model. A reduction of the heat flux to the coolant, up to a factor ∼4, and lower material temperatures were found for an incident heat flux in the range (15–30) MW/m{sup 2}. Finally, preliminary assessments were performed on the installed power required for the sweeping, the AC losses in the superconductors and thermal fatigue analysis. No evident show stoppers were found.

  18. Influence of Paralleling Dies and Paralleling Half-Bridges on Transient Current Distribution in Multichip Power Modules

    DEFF Research Database (Denmark)

    Li, Helong; Zhou, Wei; Wang, Xiongfei

    2018-01-01

    This paper addresses the transient current distribution in the multichip half-bridge power modules, where two types of paralleling connections with different current commutation mechanisms are considered: paralleling dies and paralleling half-bridges. It reveals that with paralleling dies, both t...

  19. Discrimination of Inrush from Fault Currents in Power Transformers Based on Equivalent Instantaneous Inductance Technique Coupled with Finite Element Method

    Directory of Open Access Journals (Sweden)

    M. Jamali

    2011-09-01

    Full Text Available The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equivalent instantaneous inductance (EII technique is used to discriminate inrush current from fault currents. For this purpose, a three-phase power transformer has been simulated in Maxwell software that is based on finite elements. This three-phase power transformer has been used to simulate different conditions. Then, the results have been used as inputs in MATLAB program to implement the equivalent instantaneous inductance technique. The results show that in the case of inrush current, the equivalent instantaneous inductance has a drastic variation, while it is almost constant in the cases of fault conditions.

  20. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M. (ed.)

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  1. Study of transient current induced by heavy-ion microbeams in Si and GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Hirao, Toshio; Nashiyama, Isamu; Kamiya, Tomihiro; Suda, Tamotu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    Heavy-ion microbeams were applied to the study of mechanism of single event upset (SEU). Transient current induced in p{sup +}n junction diodes by strike of heavy ion microbeam were measured by using a high-speed digitizing sampling system. (author)

  2. PSH Transient Simulation Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, Eduard [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-12-21

    PSH Transient Simulation Modeling presentation from the WPTO FY14 - FY16 Peer Review. Transient effects are an important consideration when designing a PSH system, yet numerical techniques for hydraulic transient analysis still need improvements for adjustable-speed (AS) reversible pump-turbine applications.

  3. Transient current in a quantum dot asymmetrically coupled to metallic leads

    International Nuclear Information System (INIS)

    Goker, A; Friedman, B A; Nordlander, P

    2007-01-01

    The time-dependent non-crossing approximation is used to study the transient current in a single-electron transistor attached asymmetrically to two leads following a sudden change in the energy of the dot level. We show that for asymmetric coupling, sharp features in the density of states of the leads can induce oscillations in the current through the dot. These oscillations persist to much longer timescales than the timescale for charge fluctuations. The amplitude of the oscillations increases as the temperature or source-drain bias across the dot is reduced and saturates for values below the Kondo temperature. We discuss the microscopic origin of these oscillations and comment on the possibility for their experimental detection

  4. Inrush Transient Current Analysis and Suppression of Photovoltaic Grid-Connected Inverters During Voltage Sag

    DEFF Research Database (Denmark)

    Li, Zhongyu; Zhao, Rende; Xin, Zhen

    2016-01-01

    The Inrush Transient Current (ITC) in the output of the photovoltaic grid-connected inverters is usually generated when grid voltage sag occurs, which can trigger the protection of the grid-connected inverters, and even destroy the semiconductor switches. Then, the grid-connected inverters...

  5. Fast and efficient STT switching in MTJ using additional transient pulse current

    Science.gov (United States)

    Pathak, Sachin; Cha, Jongin; Jo, Kangwook; Yoon, Hongil; Hong, Jongill

    2017-06-01

    We propose a profile of write pulse current-density to switch magnetization in a perpendicular magnetic tunnel junction to reduce switching time and write energy as well. Our simulated results show that an overshoot transient pulse current-density (current spike) imposed to conventional rectangular-shaped pulse current-density (main pulse) significantly improves switching speed that yields the reduction in write energy accordingly. For example, we could dramatically reduce the switching time by 80% and thereby reduce the write energy over 9% in comparison to the switching without current spike. The current spike affects the spin dynamics of the free layer and reduces the switching time mainly due to spin torque induced. On the other hand, the large Oersted field induced causes changes in spin texture. We believe our proposed write scheme can make a breakthrough in magnetic random access memory technology seeking both high speed operation and low energy consumption.

  6. Strain and thermally induced magnetic dynamics and spin current in magnetic insulators subject to transient optical grating

    Science.gov (United States)

    Wang, Xi-Guang; Chotorlishvili, Levan; Berakdar, Jamal

    2017-07-01

    We analyze the magnetic dynamics and particularlythe spin current in an open-circuit ferromagnetic insulator irradiated by two intense, phase-locked laser pulses. The interference of the laser beams generates a transient optical grating and a transient spatio-temporal temperature distribution. Both effects lead to elastic and heat waves at the surface and into the bulk of the sample. The strain induced spin current as well as the thermally induced magnonic spin current are evaluated numerically on the basis of micromagnetic simulations using solutions of the heat equation. We observe that the thermo-elastically induced magnonic spin current propagates on a distance larger than the characteristic size of thermal profile, an effect useful for applications in remote detection of spin caloritronics phenomena. Our findings point out that exploiting strain adds a new twist to heat-assisted magnetic switching and spin-current generation for spintronic applications.

  7. Characterization of transient discharges under atmospheric-pressure conditions applying nitrogen photoemission and current measurements

    International Nuclear Information System (INIS)

    Keller, Sandra; Rajasekaran, Priyadarshini; Bibinov, Nikita; Awakowicz, Peter

    2012-01-01

    The plasma parameters such as electron distribution function and electron density of three atmospheric-pressure transient discharges namely filamentary and homogeneous dielectric barrier discharges in air, and the spark discharge of an argon plasma coagulation (APC) system are determined. A combination of numerical simulation as well as diagnostic methods including current measurement and optical emission spectroscopy (OES) based on nitrogen emissions is used. The applied methods supplement each other and resolve problems, which arise when these methods are used individually. Nitrogen is used as a sensor gas and is admixed in low amount to argon for characterizing the APC discharge. Both direct and stepwise electron-impact excitation of nitrogen emissions are included in the plasma-chemical model applied for characterization of these transient discharges using OES where ambiguity arises in the determination of plasma parameters under specific discharge conditions. It is shown that the measured current solves this problem by providing additional information useful for the determination of discharge-specific plasma parameters. (paper)

  8. Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zevenhoven, Koos C. J.; Ilmoniemi, Risto J.; Dong, Hui; Clarke, John

    2015-01-01

    Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents

  9. Steady and transient states of a two-phase counter current flow

    International Nuclear Information System (INIS)

    Siebert, S.

    1984-06-01

    The aim of this work is to estimate the efficiency of the counter current exchange between a heavy dispersed phase and a continous light phase in a pulse perforated plate column. From an experimental point, hydraulic measurements (retention ratio, droplet size) and residence time measurements (radioactive tracers). The model will be so applied to the calculation of retention ratios in steady conditions then of tracer concentrations in transient conditions. From a numerical point of view a fixed point type iteration then a method Runge Kutta are then adapted [fr

  10. Analysis of transient signals by Wavelet transform

    International Nuclear Information System (INIS)

    Penha, Rosani Libardi da; Silva, Aucyone A. da; Ting, Daniel K.S.; Oliveira Neto, Jose Messias de

    2000-01-01

    The objective of this work is to apply the Wavelet Transform in transient signals. The Wavelet technique can outline the short time events that are not easily detected using traditional techniques. In this work, the Wavelet Transform is compared with Fourier Transform, by using simulated data and rotor rig data. This data contain known transients. The wavelet could follow all the transients, what do not happen to the Fourier techniques. (author)

  11. Nuclear reactors transients identification and classification system; Sistema de identificacao e classificacao de transientes em reatores nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, Paulo Henrique

    2008-07-01

    This work describes the study and test of a system capable to identify and classify transients in thermo-hydraulic systems, using a neural network technique of the self-organizing maps (SOM) type, with the objective of implanting it on the new generations of nuclear reactors. The technique developed in this work consists on the use of multiple networks to do the classification and identification of the transient states, being each network a specialist at one respective transient of the system, that compete with each other using the quantization error, that is a measure given by this type of neural network. This technique showed very promising characteristics that allow the development of new functionalities in future projects. One of these characteristics consists on the potential of each network, besides responding what transient is in course, could give additional information about that transient. (author)

  12. A novel solid-state control system for the minimization of re-switching transient currents of induction motor

    International Nuclear Information System (INIS)

    Abro, M.R.; Larik, A.S.; Mahar, M.A.

    2005-01-01

    This work is an investigation into the minimizing re-closure transient currents of induction motors by activating NOVEL solid state control system switching at a matched condition. This emphasis is placed upon-circuit transition starting of cage motors, particularly star-delta switching. The initial study is carried out on single-phase induction motion. This system is capable of effective sensing re-closure of a switched off running single-phase induction motor. Further this scheme could be developed to give sequential delta closure of a switched off running three-phase induction motor during 1st cycles following the opening of the star mode. Consideration is also given to the possibility of using sensed re-closure to minimize transient whenever the supply to a running induction motor is briefly interrupted, irrespective of whether the interruption is by accident design. A brief study is made into the type of transient currents generated by opening the circuit of a running induction motor. The importance of the switching pattern for star-delta starting is explained and emphasized. (author)

  13. Coherent network analysis technique for discriminating gravitational-wave bursts from instrumental noise

    International Nuclear Information System (INIS)

    Chatterji, Shourov; Lazzarini, Albert; Stein, Leo; Sutton, Patrick J.; Searle, Antony; Tinto, Massimo

    2006-01-01

    The sensitivity of current searches for gravitational-wave bursts is limited by non-Gaussian, nonstationary noise transients which are common in real detectors. Existing techniques for detecting gravitational-wave bursts assume the output of the detector network to be the sum of a stationary Gaussian noise process and a gravitational-wave signal. These techniques often fail in the presence of noise nonstationarities by incorrectly identifying such transients as possible gravitational-wave bursts. Furthermore, consistency tests currently used to try to eliminate these noise transients are not applicable to general networks of detectors with different orientations and noise spectra. In order to address this problem we introduce a fully coherent consistency test that is robust against noise nonstationarities and allows one to distinguish between gravitational-wave bursts and noise transients in general detector networks. This technique does not require any a priori knowledge of the putative burst waveform

  14. Nanorobotics current approaches and techniques

    CERN Document Server

    Ferreira, Antoine

    2013-01-01

    Nanorobot devices now perform a wide variety of tasks at the nanoscale in a wide variety of fields including but not limited to fields such as manufacturing, medicine, supply chain, biology, and outer space. Nanorobotics: Current Approaches and Techniques is a comprehensive overview of this interdisciplinary field with a wide ranging discussion that includes nano-manipulation and industrial nanorobotics, nanorobotics in biology and medicine, nanorobotic sensing, navigation and swarm behavior, and protein and DNA-based nanorobotics. Also included is the latest on topics such as bio-nano-actuators and propulsion and navigation of nanorobotic systems using magnetic fields. Nanorobotics: Current Approaches and Techniques is an ideal book for scientists, researchers, and engineers actively involved in applied and robotic research and development.

  15. Investigation of photoelectronic processes in CdIn2S4 by photoinduced current transient spectroscopy

    International Nuclear Information System (INIS)

    Serpi, A.

    1986-01-01

    Photoelectronic processes in CdIn 2 S 4 are investigated by four-gate photoinduced current transient spectroscopy. In general the photocurrent decay transients are non-exponential because of a nonlinear multichannel recombination mechanism. Nevertheless suitable extrinsic excitation allows to open one recombination channel only and so to evidence a purely exponential relaxation. The detailed analysis of this process leads to the interpretation that the defects associated with the energy levels continuously distributed below the conduction band act as relay centres for radiative recombination of photoelectrons rather than as thermal emitting traps. An electron trapping level located at about 0.6 eV from the bottom of the conduction band is also evidenced. (author)

  16. Nuclear reactors transients identification and classification system

    International Nuclear Information System (INIS)

    Bianchi, Paulo Henrique

    2008-01-01

    This work describes the study and test of a system capable to identify and classify transients in thermo-hydraulic systems, using a neural network technique of the self-organizing maps (SOM) type, with the objective of implanting it on the new generations of nuclear reactors. The technique developed in this work consists on the use of multiple networks to do the classification and identification of the transient states, being each network a specialist at one respective transient of the system, that compete with each other using the quantization error, that is a measure given by this type of neural network. This technique showed very promising characteristics that allow the development of new functionalities in future projects. One of these characteristics consists on the potential of each network, besides responding what transient is in course, could give additional information about that transient. (author)

  17. Effect of state feedback coupling on the transient performance of voltage source inverters with LC filter

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michele; Antonio DeSouza Ribeiro, Luiz

    2016-01-01

    State feedback coupling between the capacitor voltage and inductor current deteriorates notably the performance during transients of voltage and current regulators in stand-alone systems based on voltage source inverters. A decoupling technique is proposed, considering the limitations introduced...

  18. Soft controller switching technique to minimize the torque and current pulsations of a SCIM during its reswitching

    International Nuclear Information System (INIS)

    Larik, A.S.

    2010-01-01

    The direct-on-line starting of induction motor draws heavy current and to limit this Inrush current to a safe level normally a star-delta switch is used. However, the switching over from star to delta causes over current transients and this leads to torque pulsations. Therefore, in this paper the current and torque pulsations developed during the switching process are focused and a soft-switched controller is devised to minimize the re-closure transient currents and torque pulsations during star-delta switching of induction motor. The designed system can readily handles the sensing of favorable conditions of re closure of a switched-off running induction motor and it minimizes the inrush current and hence the pulsations of torque of all types of induction motors, whether, single-phase or three phase. An investigation is made into the transient currents and pulsation torques generated due to opening the circuit of a running induction motor and the switching pattern of star-delta switching. The re-switching control scheme for the induction motor is practically tested in the laboratory with and without soft controller. (author)

  19. Development of system for automatic measurement of transient photocurrent and thermally stimulated current

    Directory of Open Access Journals (Sweden)

    Asdrubal Antonio Ramirez Botero

    2017-01-01

    Full Text Available This paper presents details of the design and implementation of a system for measuring of thermally stimulated current (TSC and transient photocurrent (Iph, developed using the Virtual Instrumentation concept. For that we have used National Instrument hardware and the LabView® package as software. The system is controlled by a virtual instrument (VI which includes facilities to perform measurements of photocurrent keeping the temperature of the sample and the pressure of the chamber of measurement controlled as well as  real time display of the Iph vs t and TSC vs T curves. The system was tested by performing transient photocurrent and TSC measurements on CH3NH3PbI3 thin films that are generally used as absorbent layer of solar cells. This type of characterization is very useful to get information of the  trapping and recombination processes that affect the transport properties of the devices.

  20. Characterization of deep level defects in Tl6I4S single crystals by photo-induced current transient spectroscopy

    International Nuclear Information System (INIS)

    Peters, J A; Liu, Z; Sebastian, M; Wessels, B W; Im, J; Freeman, A J; Nguyen, S; Kanatzidis, M G

    2015-01-01

    Defect levels in semi-insulating Tl 6 I 4 S single crystals grown by the horizontal Bridgman technique have been characterized using photo-induced current transient spectroscopy (PICTS). These measurements revealed six electron traps located at (0.059  ±  0.007), (0.13  ±  0.012), (0.31  ±  0.074), (0.39  ±  0.019), (0.62  ±  0.110), and (0.597  ±  0.105). These defect levels are attributed to vacancies (V I , V S ) and antisite defects (I S , Tl S , Tl I ) upon comparison to calculations of native defect energy levels using density functional theory and defects recently reported from photoluminescence and photoconductivity measurements. (paper)

  1. Transcranial direct current stimulation transiently increases the blood-brain barrier solute permeability in vivo

    Science.gov (United States)

    Shin, Da Wi; Khadka, Niranjan; Fan, Jie; Bikson, Marom; Fu, Bingmei M.

    2016-03-01

    Transcranial Direct Current Stimulation (tDCS) is a non-invasive electrical stimulation technique investigated for a broad range of medical and performance indications. Whereas prior studies have focused exclusively on direct neuron polarization, our hypothesis is that tDCS directly modulates endothelial cells leading to transient changes in blood-brain-barrier (BBB) permeability (P) that are highly meaningful for neuronal activity. For this, we developed state-of-the-art imaging and animal models to quantify P to various sized solutes after tDCS treatment. tDCS was administered using a constant current stimulator to deliver a 1mA current to the right frontal cortex of rat (approximately 2 mm posterior to bregma and 2 mm right to sagittal suture) to obtain similar physiological outcome as that in the human tDCS application studies. Sodium fluorescein (MW=376), or FITC-dextrans (20K and 70K), in 1% BSA mammalian Ringer was injected into the rat (SD, 250-300g) cerebral circulation via the ipsilateral carotid artery by a syringe pump at a constant rate of ~3 ml/min. To determine P, multiphoton microscopy with 800-850 nm wavelength laser was applied to take the images from the region of interest (ROI) with proper microvessels, which are 100-200 micron below the pia mater. It shows that the relative increase in P is about 8-fold for small solute, sodium fluorescein, ~35-fold for both intermediate sized (Dex-20k) and large (Dex-70k) solutes, 10 min after 20 min tDCS pretreatment. All of the increased permeability returns to the control after 20 min post treatment. The results confirmed our hypothesis.

  2. Detailed investigation of current transients from metastable pitting events on stainless steel - the transition to stability

    International Nuclear Information System (INIS)

    Pistorius, P.C.; Burstein, G.T.

    1992-01-01

    Current transients which result from metastable pitting events (on Type 304 stainless steel in an acidic solution containing 1 M Cl - ) are presented. A criterion for the stable growth of open hemispherical pits is developed; the criterion states that the product of current density and pit depth must exceed a certain minimum value, to sustain rapid dissolution. Analysis of the transients from metastable pits shows that these pits fall short of this minimum, as do stable pits initially. The growth of these pits thus requires the presence of another barrier to diffusion, which is thought to be a remnant of the passive film; this forms a flawed cover over the pit mouth. When this cover ruptures under the influence of osmotic pressure, the pit repassivates. Pits growing at higher current densities approach the minimum requirement for stable growth more closely. A ''pitting potential'' results from the effect that metastable pits formed at more positive potentials grow at higher current densities, and are thus more likely to grow into stable pits. The effect of potential on the current density does not result from either activation control or ohmic control; rather, the pits grow under diffusion control. A change, with potential, of the type of pit site which can be activated, causes the potential dependence of the distribution of current densities in metastable pits. Although the distribution of current densities changes with potential, each metastable pit grows under diffusion control with a current density which is independent of the potential; this is confirmed by polarisation tests on growing metastable pits

  3. Measurement of g factors of excited states in radioactive beams by the transient field technique: 132Te

    International Nuclear Information System (INIS)

    Benczer-Koller, N.; Kumbartzki, G.; Gurdal, G; Gross, Carl J; Krieger, B; Hatarik, Robert; O'Malley, Patrick; Pain, S. D.; Segen, L.; Baktash, Cyrus; Bingham, C. R.; Danchev, M.; Grzywacz, R.; Mazzocchi, C.

    2008-01-01

    The g factor of the 2 1 + state in 52 132 Te, E(2 1 + ) = 0.9739 MeV, r = 2.6 ps, was measured by the transient field technique applied to a radioactive beam. The development of an experimental approach necessary for work in radioactive beam environments is described. The result g = 0.28(15) agrees with the previous measurement by the recoil-in-vacuum technique, but here the sign of the g factor is measured as well

  4. Differential effects of the transient outward K(+) current activator NS5806 in the canine left ventricle

    DEFF Research Database (Denmark)

    Calloe, Kirstine; Soltysinska, Ewa; Jespersen, Thomas

    2009-01-01

    To examine the electrophysiological and molecular properties of the transient outward current (I(to)) in canine left ventricle using a novel I(to) activator, NS5806, I(to) was measured in isolated epicardial (Epi), midmyocardial (Mid) and endocardial (Endo) cells using whole-cell patch-clamp tech...

  5. ESTABLISHING A STEREOSCOPIC TECHNIQUE FOR DETERMINING THE KINEMATIC PROPERTIES OF SOLAR WIND TRANSIENTS BASED ON A GENERALIZED SELF-SIMILARLY EXPANDING CIRCULAR GEOMETRY

    International Nuclear Information System (INIS)

    Davies, J. A.; Perry, C. H.; Harrison, R. A.; Trines, R. M. G. M.; Lugaz, N.; Möstl, C.; Liu, Y. D.; Steed, K.

    2013-01-01

    The twin-spacecraft STEREO mission has enabled simultaneous white-light imaging of the solar corona and inner heliosphere from multiple vantage points. This has led to the development of numerous stereoscopic techniques to investigate the three-dimensional structure and kinematics of solar wind transients such as coronal mass ejections (CMEs). Two such methods—triangulation and the tangent to a sphere—can be used to determine time profiles of the propagation direction and radial distance (and thereby radial speed) of a solar wind transient as it travels through the inner heliosphere, based on its time-elongation profile viewed by two observers. These techniques are founded on the assumption that the transient can be characterized as a point source (fixed φ, FP, approximation) or a circle attached to Sun-center (harmonic mean, HM, approximation), respectively. These geometries constitute extreme descriptions of solar wind transients, in terms of their cross-sectional extent. Here, we present the stereoscopic expressions necessary to derive propagation direction and radial distance/speed profiles of such transients based on the more generalized self-similar expansion (SSE) geometry, for which the FP and HM geometries form the limiting cases; our implementation of these equations is termed the stereoscopic SSE method. We apply the technique to two Earth-directed CMEs from different phases of the STEREO mission, the well-studied event of 2008 December and a more recent event from 2012 March. The latter CME was fast, with an initial speed exceeding 2000 km s –1 , and highly geoeffective, in stark contrast to the slow and ineffectual 2008 December CME

  6. Effect of load transients on SOFC operation—current reversal on loss of load

    Science.gov (United States)

    Gemmen, Randall S.; Johnson, Christopher D.

    The dynamics of solid oxide fuel cell (SOFC) operation have been considered previously, but mainly through the use of one-dimensional codes applied to co-flow fuel cell systems. In this paper several geometries are considered, including cross-flow, co-flow, and counter-flow. The details of the model are provided, and the model is compared with some initial experimental data. For parameters typical of SOFC operation, a variety of transient cases are investigated, including representative load increase and decrease and system shutdown. Of particular note for large load decrease conditions (e.g., shutdown) is the occurrence of reverse current over significant portions of the cell, starting from the moment of load loss up to the point where equilibrated conditions again provide positive current. Consideration is given as to when such reverse current conditions might most significantly impact the reliability of the cell.

  7. ELECTROMECHANICAL TRANSIENT PROCESSES DURING SUPPLY VOLTAGE CHANGING IN THE SYSTEM OF POLYMER INSULATION COVERING OF THE CURRENT-CARRYING CORE OF ULTRA HIGH VOLTAGE CABLES

    Directory of Open Access Journals (Sweden)

    V. M. Zolotaryov

    2018-04-01

    Full Text Available Aim. The article is devoted to the analysis of the electromechanical transient processes in a system of three frequency-controlled electric drives based on asynchronous motors that control current-carrying core motion, as well as to the study of the effect of such processes on the modes applying three-layer polymer insulation to the current-carrying core. Technique. The study was conducted based on the concepts of electromechanics, electromagnetic field theory, mathematical physics, mathematical modeling. Results. A mathematical model has been developed to analyze transients in an electromechanical system consisting of three frequency-controlled electric drives providing current-carrying core motion of ultra-high voltage cables in an inclined extrusion line. The coordination of the electromechanical parameters of the system drives has been carried out and the permissible changes in the supply voltage at the limiting mass while moving current-carrying core of ultra-high voltage cables with applied polymer insulation have been estimated. Scientific novelty. For the first time it is determined that with the limiting mass of the current-carrying core, the electromechanical system allows to stabilize the current-carrying core speed with the required accuracy at short-term decreases in the supply voltage by no more than 27 % of its amplitude value. It is also shown that this system is resistant to short-term increases in voltage by 32 % for 0.2 s. Practical significance. Using the developed model, it is possible to calculate the change in the configuration and speed of the slack current-carrying core when applying polymer insulation, depending on the specific mass of the current-carrying core per unit length, its tension at the bottom, the torque of the traction motor and the supply voltage to achieve stable operation of the system and accurate working of the set parameters.

  8. A transient absorption study of allophycocyanin

    Indian Academy of Sciences (India)

    Transient dynamics of allophycocyanin trimers and monomers are observed by using the pump-probe, transient absorption technique. The origin of spectral components of the transient absorption spectra is discussed in terms of both kinetics and spectroscopy. We find that the energy gap between the ground and excited ...

  9. One gigasample per second transient recorder: a performance demonstration

    International Nuclear Information System (INIS)

    Linnenbrink, T.E.; Gradl, D.A.; Ritt, D.M.; DeWitte, G.J.; Hutton, J.D.

    1982-01-01

    The performance demonstrated by a one gigasample per second (1 Gs/s) transient recorder currently in advanced development portends an important new instrument for recording single transient data. A Charge-Coupled Device (CCD) is used to sample a continuous analog signal. Samples acquired at the full sampling rate (1 Gs/s) are temporarily stored in the CCD, then read out at a slow rate (e.g., 250 Ks/s) into a conventional analog-to-digital converter prior to storage in nonvolatile, digital memory. Enhanced circuitry and techniques developed over the past three years have yielded higher performance than originally anticipated. Accordingly, the target specification has been revised to reflect higher expectations

  10. A Decentralized Current-Sharing Controller Endows Fast Transient Response to Parallel DC-DC Converters

    DEFF Research Database (Denmark)

    Wang, Haojie; Han, Minxiao; Han, Renke

    2018-01-01

    This paper proposes a decentralized current-sharing control strategy to endow fast transient response to paralleled DC-DC converters systems, such as DC microgrids or distributed power systems. The proposed controller consist of two main control loops: an external voltage droop control for current......-sharing proposes and an internal current loop. The external droop control loop is designed as a voltage loop with embedded virtual impedance, which avoids the use of a slow voltage loop and a separate extra virtual impedance loop that may limit the system bandwidth. The internal current loop, thanks...... and the proposed embedded-virtual-impedance based I-V droop. In order to compare the dynamic response performances between two droop controllers, their state-space models have been developed and analyzed in this paper. The results show that the dynamic response of the I-V droop control is faster than...

  11. A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

    Science.gov (United States)

    Shen, Yang-Wu; Ke, De-Ping; Sun, Yuan-Zhang; Daniel, Kirschen; Wang, Yi-Shen; Hu, Yuan-Chao

    2015-07-01

    A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method. Project supported by the National Natural Science Foundation of China (Grant No. 51307124) and the Major Program of the National Natural Science Foundation of China (Grant No. 51190105).

  12. Application of a combined superconducting fault current limiter and STATCOM to enhancement of power system transient stability

    Energy Technology Data Exchange (ETDEWEB)

    Mahdad, Belkacem, E-mail: bemahdad@mselab.org; Srairi, K.

    2013-12-15

    Highlights: •A simple interactive model SFCL–STATCOM Controller is proposed to enhance the transient stability. •The STATCOM controller is integrated in coordination with the SFCL to support the excessive reactive power during fault. •Voltage stability index based continuation power flow is used to locate the STATCOM and the SFCL. •The clearing time improved compared to other cases (with only SFCL, with only STATCOM). •The choice of the STATCOM parameters is very important to exploit efficiently the integration of STATCOM Controller. -- Abstract: Stable and reliable operation of the power system network is dependent on the dynamic equilibrium between energy production and power demand under large disturbance such as short circuit or important line tripping. This paper investigates the use of combined model based superconducting fault current limiter (SFCL) and shunt FACTS Controller (STATCOM) for assessing the transient stability of a power system considering the automatic voltage regulator. The combined model located at a specified branch based on voltage stability index using continuation power flow. The main role of the proposed combined model is to achieve simultaneously a flexible control of reactive power using STATCOM Controller and to reduce fault current using superconducting technology based SFCL. The proposed combined model has been successfully adapted within the transient stability program and applied to enhance the transient power system stability of the WSCC9-Bus system. Critical clearing time (CCT) has been used as an index to evaluate and validate the contribution of the proposed coordinated Controller. Simulation results confirm the effectiveness and perspective of this combined Controller to enhance the dynamic power system performances.

  13. A New Technique for SET Pulse Width Measurement in Chains of Inverters Using Pulsed Laser Irradiation

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Fel, N.; Gaillardin, M.; Baggio, J.; Girard, S.; Flament, O.; Paillet, P.; McMorrow, D.; Melinger, J. S.; Kobayashi, D.; Hirose, K.; Saito, H.; Pouget, V.; Essely, F.; Schwank, J. R.; Flores, R. S.; Dodd, P. E.; Shaneyfelt, M. R.

    2009-01-01

    A new technique is developed to measure precisely and accurately the width of propagating voltage transients induced by irradiation of inverter chains. The technique is based on measurement of the supply current in a detection inverter, and permits a direct determination of the transient width with a 50 GHz bandwidth. (authors)

  14. Current thinking: return to play and transient quadriplegia.

    Science.gov (United States)

    Cantu, Robert V; Cantu, Robert C

    2005-02-01

    Athletes that participate in contact and collision sports assume risk of serious injury each time they take the field. For those athletes that have sustained an episode of transient quadriplegia, the decision of whether to return to competition can be a difficult one. Some athletes, realizing how close they may have come to permanent injury, may decide that further participation is not in their best interest. Others may be somewhat undecided, and some may want to return at all costs. As the treating physician, the goal is to identify those athletes who after a single episode of transient quadriplegia are at increased risk for further injury and consequently should discontinue participation in contact sports. Factors that may contribute to that determination include mechanism of injury, prior history of neurologic symptoms or injury, and anatomic features that may predispose to further injury such as disc herniation, fracture, or cervical stenosis.

  15. Radiation of transient high-current arcs: energy measurements in the optical range

    International Nuclear Information System (INIS)

    Bauchire, J M; Hong, D; Rabat, H; Riquel, G

    2012-01-01

    When no protection is used, the radiation emitted by a high-power electric arc can be dangerous for the eyes and the skin of a person. To ensure effective protection, it is first necessary to know the energy emitted by such arcs. The aim of our work was to experimentally determine the energy emitted by high-current (from 4 to 40 kA) transient arcs, for two different (10 cm and 2 m) lengths and for electrodes in copper or steel. These experiments enabled the radiative energy of the arcs to be quantified and also showed the influence of metal vapors in the spectral distribution of the radiation.

  16. Non-Destructive Techniques Based on Eddy Current Testing

    Science.gov (United States)

    García-Martín, Javier; Gómez-Gil, Jaime; Vázquez-Sánchez, Ernesto

    2011-01-01

    Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future. PMID:22163754

  17. Thermal conductivity measurement of the He-ion implanted layer of W using transient thermoreflectance technique

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Shilian; Li, Yuanfei [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Wang, Zhigang [Department of Electronic Engineering, Dalian University of Technology, Dalian 116024 (China); Jia, Yuzhen [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Science and Technology on Reactor Fuel and Materials Laboratory, Nuclear Power Institute of China, Chengdu 610213 (China); Li, Chun [School of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144 (China); Xu, Ben; Chen, Wanqi [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China); Bai, Suyuan [School of Physics and Electronic Technology, Liaoning Normal University, Dalian 116029 (China); Huang, Zhengxing; Tang, Zhenan [Department of Electronic Engineering, Dalian University of Technology, Dalian 116024 (China); Liu, Wei, E-mail: liuw@mail.tsinghua.edu.cn [Laboratory of Advanced Materials, School of Materials Science and Engineering, Tsinghua University, Beijing 100084 (China)

    2017-02-15

    Transient thermoreflectance method was applied on the thermal conductivity measurement of the surface damaged layer of He-implanted tungsten. Uniform damages tungsten surface layer was produced by multi-energy He-ion implantation with thickness of 450 nm. Result shows that the thermal conductivity is reduced by 90%. This technique was further applied on sample with holes on the surface, which was produced by the He-implanted at 2953 K. The thermal conductivity decreases to 3% from the bulk value.

  18. Analyzing transient closed chamber effects on canopy gas exchange for optimizing flux calculation timing

    NARCIS (Netherlands)

    Langensiepen, M.; Kupisch, M.; Wijk, van M.T.; Ewert, F.

    2012-01-01

    Transient type canopy chambers are still the only currently available practical solution for rapid screening of gas-exchange in agricultural fields. The technique has been criticized for its effect on canopy microclimate during measurement which affects the transport regime and regulation of plant

  19. Transient voltage control of a DFIG-based wind power plant for suppressing overvoltage using a reactive current reduction loop

    Directory of Open Access Journals (Sweden)

    Geon Park

    2016-01-01

    Full Text Available This paper proposes a transient voltage control scheme of a doubly fed induction generator (DFIG-based wind power plant (WPP using a reactive current reduction loop to suppress the overvoltage at a point of interconnection (POI and DFIG terminal after a fault clearance. The change of terminal voltage of a DFIG is monitored at every predefined time period to detect the fault clearance. If the voltage change exceeds a set value, then the reactive current reduction loop reduces the reactive current reference in the DFIG controller using the step function. The reactive current injection of DFIGs in a WPP is rapidly reduced, and a WPP can rapidly suppress the overvoltage at a fault clearance because the reactive current reference is reduced. Using an electromagnetic transients program–released version (EMTP–RV simulator, the performance of the proposed scheme was validated for a model system comprising 20 units of a 5-MW DFIG considering various scenarios, such as fault and wind conditions. Test results show that the proposed scheme enables a WPP to suppress the overvoltage at the POI and DFIG terminal within a short time under grid fault conditions.

  20. Transient flows occurring during the accelerated crucible rotation technique

    International Nuclear Information System (INIS)

    Horowitz, Atara; Horowitz, Yigal

    1992-11-01

    The transient flows occurring after a change in the angular velocity of the cylindrical container are described. The dependence of the transient (known as spin-up or spin-down time) on experimental parameters as kinematic viscosity, cylinder dimensions and the cylinder's initial and final angular velocities are elucidates by a review of the literature. It is emphasized that with large Rossby numbers the spin-up time is longer and the amount of fluid mixing is greater than small and moderate Rossby numbers. It is also elucidated that most crystal growth crucibles cannot be considered as infinitely-long cylinders for the evaluation of the fluid dynamics (authors)

  1. Transient hardened power FETs

    International Nuclear Information System (INIS)

    Dawes, W.R. Jr.; Fischer, T.A.; Huang, C.C.C.; Meyer, W.J.; Smith, C.S.; Blanchard, R.A.; Fortier, T.J.

    1986-01-01

    N-channel power FETs offer significant advantages in power conditioning circuits. Similiarily to all MOS technologies, power FET devices are vulnerable to ionizing radiation, and are particularily susceptible to burn-out in high dose rate irradiations (>1E10 rads(Si)/sec.), which precludes their use in many military environments. This paper will summarize the physical mechanisms responsible for burn-out, and discuss various fabrication techniques designed to improve the transient hardness of power FETs. Power FET devices were fabricated with several of these techniques, and data will be presented which demonstrates that transient hardness levels in excess of 1E12 rads(Si)/sec. are easily achievable

  2. Rate transient analysis for homogeneous and heterogeneous gas reservoirs using the TDS technique

    International Nuclear Information System (INIS)

    Escobar, Freddy Humberto; Sanchez, Jairo Andres; Cantillo, Jose Humberto

    2008-01-01

    In this study pressure test analysis in wells flowing under constant wellbore flowing pressure for homogeneous and naturally fractured gas reservoir using the TDS technique is introduced. Although, constant rate production is assumed in the development of the conventional well test analysis methods, constant pressure production conditions are sometimes used in the oil and gas industry. The constant pressure technique or rate transient analysis is more popular reckoned as decline curve analysis under which rate is allows to decline instead of wellbore pressure. The TDS technique, everyday more used even in the most recognized software packages although without using its trade brand name, uses the log-log plot to analyze pressure and pressure derivative test data to identify unique features from which exact analytical expression are derived to easily estimate reservoir and well parameters. For this case, the fingerprint characteristics from the log-log plot of the reciprocal rate and reciprocal rate derivative were employed to obtain the analytical expressions used for the interpretation analysis. Many simulation experiments demonstrate the accuracy of the new method. Synthetic examples are shown to verify the effectiveness of the proposed methodology

  3. Demonstrate use of capillary electrophoresis low level transient of anions

    International Nuclear Information System (INIS)

    Moum, Kari-Lye; Solheim, Torill; McElrath, Joel; Frattini, Paul

    2012-09-01

    Capillary Electrophoresis (CE) is a well-known analytical method capable of rapid detection of very low concentration of cations and anionic species such as chloride, sulfate and nitrate. These anions are of crucial importance in reducing the potential of stainless steel components to undergo stress corrosion cracking. Currently, Nuclear Power Plants (NPPs) use Ion Chromatography (IC) as the analytical technique to achieve the required detection levels of ionic species. At the Halden Reactor Project (HRP) IC was replaced by CE in 1996, and since then HRP has gained nearly 20 years of operational experience. During the last 15 years, EPRI has done research on the CE technique and has achieved extensive experience in this area. EPRI has demonstrated detection levels at ppt and sub-ppb levels. This paper presents the ability of the CE technique to follow low level transients of anions in Boiling Water Reactor (BWR) coolant. A transient caused by approx. 10 ppb chloride and sulfate was simulated in an experimental circuit simulating BWR conditions. A series of grab samples were taken and analysed using HRPs CE (Agilent G1600). (authors)

  4. Statistical interpretation of transient current power-law decay in colloidal quantum dot arrays

    Energy Technology Data Exchange (ETDEWEB)

    Sibatov, R T, E-mail: ren_sib@bk.ru [Ulyanovsk State University, 432000, 42 Leo Tolstoy Street, Ulyanovsk (Russian Federation)

    2011-08-01

    A new statistical model of the charge transport in colloidal quantum dot arrays is proposed. It takes into account Coulomb blockade forbidding multiple occupancy of nanocrystals and the influence of energetic disorder of interdot space. The model explains power-law current transients and the presence of the memory effect. The fractional differential analogue of the Ohm law is found phenomenologically for nanocrystal arrays. The model combines ideas that were considered as conflicting by other authors: the Scher-Montroll idea about the power-law distribution of waiting times in localized states for disordered semiconductors is applied taking into account Coulomb blockade; Novikov's condition about the asymptotic power-law distribution of time intervals between successful current pulses in conduction channels is fulfilled; and the carrier injection blocking predicted by Ginger and Greenham (2000 J. Appl. Phys. 87 1361) takes place.

  5. Statistical interpretation of transient current power-law decay in colloidal quantum dot arrays

    International Nuclear Information System (INIS)

    Sibatov, R T

    2011-01-01

    A new statistical model of the charge transport in colloidal quantum dot arrays is proposed. It takes into account Coulomb blockade forbidding multiple occupancy of nanocrystals and the influence of energetic disorder of interdot space. The model explains power-law current transients and the presence of the memory effect. The fractional differential analogue of the Ohm law is found phenomenologically for nanocrystal arrays. The model combines ideas that were considered as conflicting by other authors: the Scher-Montroll idea about the power-law distribution of waiting times in localized states for disordered semiconductors is applied taking into account Coulomb blockade; Novikov's condition about the asymptotic power-law distribution of time intervals between successful current pulses in conduction channels is fulfilled; and the carrier injection blocking predicted by Ginger and Greenham (2000 J. Appl. Phys. 87 1361) takes place.

  6. Physiological roles of the transient outward current Ito in normal and diseased hearts

    DEFF Research Database (Denmark)

    Cordeiro, Jonathan M.; Callø, Kirstine; Aschar-Sobbi, Roozbeh

    2016-01-01

    The Ca2+-independent transient outward K+ current (Ito) plays a critical role in underlying phase 1 of repolarization of the cardiac action potential and, as a result, is central to modulating excitation-contraction coupling and propensity for arrhythmia. Additionally, Ito and its molecular...... potential and the mechanisms by which Ito modulates excitation-contraction coupling. We also describe the effects of mutations in the subunits constituting the Ito channel as well as the role of Ito in the failing myocardium. Finally, we review pharmacological modulation of Ito and discuss the evidence...... constituents are consistently reduced in cardiac hypertrophy and heart failure. In this review, we discuss the physiological role of Ito as well as the molecular basis of this current in human and canine hearts, in which Ito has been thoroughly studied. In particular, we discuss the role of Ito in the action...

  7. Transient characteristics of current lead losses for the large scale high-temperature superconducting rotating machine

    International Nuclear Information System (INIS)

    Le, T. D.; Kim, J. H.; Park, S. I.; Kim, D. J.; Kim, H. M.; Lee, H. G.; Yoon, Y. S.; Jo, Y. S.; Yoon, K. Y.

    2014-01-01

    To minimize most heat loss of current lead for high-temperature superconducting (HTS) rotating machine, the choice of conductor properties and lead geometry - such as length, cross section, and cooling surface area - are one of the various significant factors must be selected. Therefore, an optimal lead for large scale of HTS rotating machine has presented before. Not let up with these trends, this paper continues to improve of diminishing heat loss for HTS part according to different model. It also determines the simplification conditions for an evaluation of the main flux flow loss and eddy current loss transient characteristics during charging and discharging period.

  8. Studies of implicit and explicit solution techniques in transient thermal analysis of structures

    International Nuclear Information System (INIS)

    Adelman, H.M.; Haftka, R.T.; Robinson, J.C.

    1982-08-01

    Studies aimed at an increase in the efficiency of calculating transient temperature fields in complex aerospace vehicle structures are reported. The advantages and disadvantages of explicit and implicit algorithms are discussed and a promising set of implicit algorithms with variable time steps, known as GEARIB, is described. Test problems, used for evaluating and comparing various algorithms, are discussed and finite element models of the configurations are described. These problems include a coarse model of the Space Shuttle wing, an insulated frame test article, a metallic panel for a thermal protection system, and detailed models of sections of the Space Shuttle wing. Results generally indicate a preference for implicit over explicit algorithms for transient structural heat transfer problems when the governing equations are stiff (typical of many practical problems such as insulated metal structures). The effects on algorithm performance of different models of an insulated cylinder are demonstrated. The stiffness of the problem is highly sensitive to modeling details and careful modeling can reduce the stiffness of the equations to the extent that explicit methods may become the best choice. Preliminary applications of a mixed implicit-explicit algorithm and operator splitting techniques for speeding up the solution of the algebraic equations are also described

  9. Studies of implicit and explicit solution techniques in transient thermal analysis of structures

    Science.gov (United States)

    Adelman, H. M.; Haftka, R. T.; Robinson, J. C.

    1982-01-01

    Studies aimed at an increase in the efficiency of calculating transient temperature fields in complex aerospace vehicle structures are reported. The advantages and disadvantages of explicit and implicit algorithms are discussed and a promising set of implicit algorithms with variable time steps, known as GEARIB, is described. Test problems, used for evaluating and comparing various algorithms, are discussed and finite element models of the configurations are described. These problems include a coarse model of the Space Shuttle wing, an insulated frame tst article, a metallic panel for a thermal protection system, and detailed models of sections of the Space Shuttle wing. Results generally indicate a preference for implicit over explicit algorithms for transient structural heat transfer problems when the governing equations are stiff (typical of many practical problems such as insulated metal structures). The effects on algorithm performance of different models of an insulated cylinder are demonstrated. The stiffness of the problem is highly sensitive to modeling details and careful modeling can reduce the stiffness of the equations to the extent that explicit methods may become the best choice. Preliminary applications of a mixed implicit-explicit algorithm and operator splitting techniques for speeding up the solution of the algebraic equations are also described.

  10. Lithium Battery Transient Response as a Diagnostic Tool

    Science.gov (United States)

    Denisov, E.; Nigmatullin, R.; Evdokimov, Y.; Timergalina, G.

    2018-05-01

    Lithium batteries are currently used as the main energy storage for electronic devices. Progress in the field of portable electronic devices is significantly determined by the improvement of their weight/dimensional characteristics and specific capacity. In addition to the high reliability required of lithium batteries, in some critical applications proper diagnostics are required. Corresponding techniques allow prediction and prevention of operation interruption and avoidance of expensive battery replacement, and also provide additional benefits. Many effective diagnostic methods have been suggested; however, most of them require expensive experimental equipment, as well as interruption or strong perturbation of the operating mode. In the framework of this investigation, a simple diagnostic method based on analysis of transient processes is proposed. The transient response is considered as a reaction to an applied load variation that typically corresponds to normal operating conditions for most real applications. The transient response contains the same information as the impedance characteristic for the system operating in linear mode. Taking into account the large number of publications describing the impedance response associated with diagnostic methods, it can be assumed that the transient response contains a sufficient amount of information for creation of effective diagnostic systems. The proposed experimental installation is based on a controlled load, providing current variation, measuring equipment, and data processing electronics. It is proposed to use the second exponent parameters U 2 and β to estimate the state of charge for secondary lithium batteries. The proposed method improves the accuracy and reliability of a set of quantitative parameters associated with electrochemical energy sources.

  11. About the parametrizations utilized to perform magnetic moments measurements using the transient field technique

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, A. M., E-mail: amgomezl-1@uqvirtual.edu.co [Programa de Física, Universidad del Quindo (Colombia); Torres, D. A., E-mail: datorresg@unal.edu.co [Physics Department, Universidad Nacional de Colombia, Bogotá (Colombia)

    2016-07-07

    The experimental study of nuclear magnetic moments, using the Transient Field technique, makes use of spin-orbit hyperfine interactions to generate strong magnetic fields, above the kilo-Tesla regime, capable to create a precession of the nuclear spin. A theoretical description of such magnetic fields is still under theoretical research, and the use of parametrizations is still a common way to address the lack of theoretical information. In this contribution, a review of the main parametrizations utilized in the measurements of Nuclear Magnetic Moments will be presented, the challenges to create a theoretical description from first principles will be discussed.

  12. Featuring of transient tunneling current by voltage pulse and application to an electrochemical biosensor

    Science.gov (United States)

    Yun, Jun Yeon; Lee, Won Cheol; Choi, Seong Wook; Park, Young June

    2018-03-01

    We suggest a voltage pulse method for detecting the transient tunneling current component (faradaic current component) in a metal/redox-active monolayer/electrolyte system. After applying the pulse to the metal electrode, the capacitive current prevails; therefore, it is difficult to extract the tunneling current, which carries information on the biochemical reactions occurring between the biomarkers in the electrolyte and the self-assembled monolayer (SAM) as the probe peptide system. Instead of waiting until the capacitive current diminishes, and thereby, the tunneling current also decreases, we try to extract the tunneling current in an early stage of the pulse. The method is based on the observation that the capacitive current becomes symmetrized in the positive and negative pulses after introducing the SAM on the metal electrode. When the energy level of the redox molecule is higher than the Fermi level of the metal under zero-bias condition, the tunneling current in the negative pulse can be extracted by subtracting the capacitive current obtained from the positive pulse, where the tunneling current is neglected. The experiment conducted for detecting trypsin as a biomarker shows that the method enhances the sensitivity and the specific-to-nonspecific ratio of the sensor device in the case of the nonspecific protein-abundant electrolyte solution, as evinced by cyclic voltammetry measurements in comparison.

  13. Fault Diagnosis of Induction Machines in a Transient Regime Using Current Sensors with an Optimized Slepian Window.

    Science.gov (United States)

    Burriel-Valencia, Jordi; Puche-Panadero, Ruben; Martinez-Roman, Javier; Sapena-Bano, Angel; Pineda-Sanchez, Manuel

    2018-01-06

    The aim of this paper is to introduce a new methodology for the fault diagnosis of induction machines working in the transient regime, when time-frequency analysis tools are used. The proposed method relies on the use of the optimized Slepian window for performing the short time Fourier transform (STFT) of the stator current signal. It is shown that for a given sequence length of finite duration, the Slepian window has the maximum concentration of energy, greater than can be reached with a gated Gaussian window, which is usually used as the analysis window. In this paper, the use and optimization of the Slepian window for fault diagnosis of induction machines is theoretically introduced and experimentally validated through the test of a 3.15-MW induction motor with broken bars during the start-up transient. The theoretical analysis and the experimental results show that the use of the Slepian window can highlight the fault components in the current's spectrogram with a significant reduction of the required computational resources.

  14. Electromagnetic transient analysis and Novell protective relaying techniques for power transformers

    CERN Document Server

    Lin, X; Tian, Q; Weng, H

    2015-01-01

    This book addresses the technical challenges of transformer malfunction analysis as well as protection. One of the current research directions is the malfunction mechanism analysis due to nonlinearity of transformer core and comprehensive countermeasures on improving the performance of transformer differential protection. Here, the authors summarize their research outcomes and present a set of recent research advances in the electromagnetic transient analysis, the application on power transformer protections, and present a more systematic investigation and review in this field. This research area is still progressing, especially with the fast development of Smart Grid. This book is an important addition to the literature and will enhance significant advancement in research. It is a good reference book for researchers in power transformer protection research and a good text book for graduate and undergraduate students in electrical engineering.

  15. The edge transient-current technique (E-TCT) with high energy hadron beam

    Energy Technology Data Exchange (ETDEWEB)

    Gorišek, Andrej; Cindro, Vladimir; Kramberger, Gregor; Mandić, Igor [J. Stefan Institute, Ljubljana (Slovenia); Mikuž, Marko [J. Stefan Institute, Ljubljana (Slovenia); University of Ljubljana (Slovenia); Muškinja, Miha; Zavrtanik, Marko [J. Stefan Institute, Ljubljana (Slovenia)

    2016-09-21

    We propose a novel way to investigate the properties of silicon and CVD diamond detectors for High Energy Physics experiments complementary to the already well-established E-TCT technique using laser beam. In the proposed setup the beam of high energy hadrons (MIPs) is used instead of laser beam. MIPs incident on the detector in the direction parallel to the readout electrode plane and perpendicular to the edge of the detector. Such experiment could prove very useful to study CVD diamond detectors that are almost inaccessible for the E-TCT measurements with laser due to large band-gap as well as to verify and complement the E-TCT measurements of silicon. The method proposed is being tested at CERN in a beam of 120 GeV hadrons using a reference telescope with track resolution at the DUT of few μm. The preliminary results of the measurements are presented.

  16. Environmentally-induced discharge transient coupling to spacecraft

    Science.gov (United States)

    Viswanathan, R.; Barbay, G.; Stevens, N. J.

    1985-01-01

    The Hughes SCREENS (Space Craft Response to Environments of Space) technique was applied to generic spin and 3-axis stabilized spacecraft models. It involved the NASCAP modeling for surface charging and lumped element modeling for transients coupling into a spacecraft. A differential voltage between antenna and spun shelf of approx. 400 V and current of 12 A resulted from discharge at antenna for the spinner and approx. 3 kv and 0.3 A from a discharge at solar panels for the 3-axis stabilized Spacecraft. A typical interface circuit response was analyzed to show that the transients would couple into the Spacecraft System through ground points, which are most vulnerable. A compilation and review was performed on 15 years of available data from electron and ion current collection phenomena. Empirical models were developed to match data and compared with flight data of Pix-1 and Pix-2 mission. It was found that large space power systems would float negative and discharge if operated at or above 300 V. Several recommendations are given to improve the models and to apply them to large space systems.

  17. Robust low frequency current ripple elimination algorithm for grid-connected fuel cell systems with power balancing technique

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong-Soo; Choe, Gyu-Yeong; Lee, Byoung-Kuk [School of Information and Communication Engineering, Sungkyunkwan University, 300 Cheoncheon-dong, Jangan-gu, Suwon, Gyeonggi-do 440-746 (Korea, Republic of); Kang, Hyun-Soo [R and D Center, Advanced Drive Technology (ADT) Company, 689-26 Geumjeong-dong, Gunpo-si, Gyeonggi-do 435-862 (Korea, Republic of)

    2011-05-15

    The low frequency current ripple in grid-connected fuel cell systems is generated from dc-ac inverter operation, which generates 60 Hz fundamental component, and gives harmful effects on fuel cell stack itself, such as making cathode surface responses slower, causing an increase of more than 10% in the fuel consumption, creating oxygen starvation, causing a reduction in the operating lifetime, and incurring a nuisance tripping such as overload situation. With these reasons, low frequency current ripple makes fuel cell system unstable and lifetime of fuel cell stack itself short. This paper presents a fast and robust control algorithm to eliminate low frequency current ripple in grid-connected fuel cell systems. Compared with the conventional methods, in the proposed control algorithm, dc link voltage controller is shifted from dc-dc converter to dc-ac inverter, resulting that dc-ac inverter handles dc link voltage control and output current control simultaneously with help of power balancing technique. The results indicate that the proposed algorithm can not only completely eliminate current ripple but also significantly reduce the overshoot or undershoot during transient states without any extra hardware. The validity of the proposed algorithm is verified by computer simulations and also by experiments with a 1 kW laboratory prototype. (author)

  18. Techniques and instrumentation for the measurement of transient sound energy flux

    Science.gov (United States)

    Watkinson, P. S.; Fahy, F. J.

    1983-12-01

    The evaluation of sound intensity distributions, and sound powers, of essentially continuous sources such as automotive engines, electric motors, production line machinery, furnaces, earth moving machinery and various types of process plants were studied. Although such systems are important sources of community disturbance and, to a lesser extent, of industrial health hazard, the most serious sources of hearing hazard in industry are machines operating on an impact principle, such as drop forges, hammers and punches. Controlled experiments to identify major noise source regions and mechanisms are difficult because it is normally impossible to install them in quiet, anechoic environments. The potential for sound intensity measurement to provide a means of overcoming these difficulties has given promising results, indicating the possibility of separation of directly radiated and reverberant sound fields. However, because of the complexity of transient sound fields, a fundamental investigation is necessary to establish the practicability of intensity field decomposition, which is basic to source characterization techniques.

  19. Field transients of coherent terahertz synchrotron radiation accessed via time-resolving and correlation techniques

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, A.; Hübers, H.-W. [Humboldt-Universität zu Berlin, Institute of Physics, Newtonstraße 15, 12489 Berlin (Germany); Institute of Optical Sensor Systems, German Aerospace Center (DLR), Rutherfordstrasse 29, 12489 Berlin (Germany); Semenov, A. [Institute of Optical Sensor Systems, German Aerospace Center (DLR), Rutherfordstrasse 29, 12489 Berlin (Germany); Hoehl, A.; Ulm, G. [Physikalisch-Technische Bundesanstalt (PTB), Abbestraße 2-12, 10587 Berlin (Germany); Ries, M.; Wüstefeld, G. [Helmholz-Zentrum Berlin, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Ilin, K.; Thoma, P.; Siegel, M. [Institute of Micro- and Nanoelectronic Systems, Karlsruhe Institute of Technology (KIT), Hertzstrasse 16, 76187 Karlsruhe (Germany)

    2016-03-21

    Decaying oscillations of the electric field in repetitive pulses of coherent synchrotron radiation in the terahertz frequency range was evaluated by means of time-resolving and correlation techniques. Comparative analysis of real-time voltage transients of the electrical response and interferograms, which were obtained with an ultrafast zero-bias Schottky diode detector and a Martin-Puplett interferometer, delivers close values of the pulse duration. Consistent results were obtained via the correlation technique with a pair of Golay Cell detectors and a pair of resonant polarisation-sensitive superconducting detectors integrated on one chip. The duration of terahertz synchrotron pulses does not closely correlate with the duration of single-cycle electric field expected for the varying size of electron bunches. We largely attribute the difference to the charge density oscillations in electron bunches and to the low-frequency spectral cut-off imposed by both the synchrotron beamline and the coupling optics of our detectors.

  20. Technique and Calculation Results of Currents and Voltages in the Circuits of the Measuring Element of the Protection Device of the Transmission Line Based on the Control of Transient Processes

    Science.gov (United States)

    Lachugin, V. F.; Kulikov, A. L.; Platonov, P. S.; Vucolov, V. Yu.

    2017-12-01

    The specifics of generation of the signals of current and voltage in the circuits of a directional element of wave relay protection during short circuit (SC) in overhead power transmission lines are considered. The computing method of transient processes in the protection circuits, including frequency filters, that attenuate the parameters of currents and voltages of the mode taking into account the higher harmonic components and probable deviations of the frequency of transmission line from the rated value is presented. It is revealed that it is advisable to implement the measuring circuits of the directional elements of wave relay protection with the three-section filter attenuating the frequencies from 45 to 55 Hz and the low pass filter with cutoff frequency that does not exceed 1 kHz.

  1. Photo-induced current transient spectroscopy for high-resistivity neutron-transmutation-doped silicon

    International Nuclear Information System (INIS)

    Tokuda, Yutaka; Inoue, Yajiro; Usami, Akira

    1987-01-01

    Defects in high-resistivity neutron-transmutation-doped (NTD) silicon prior to annealing were studied by photo-induced current transient spectroscopy (PICTS). The thermal-neutron fluence was 9.5 x 10 17 cm -2 to give a resistivity of about 30 Ω after annealing, and the fast-neutron fluence was 9.5 x 10 16 cm -2 . Four traps with thermal emission activation energies of 0.15, 0.41. 0.47 and 0.50 eV were observed in NTD silicon. A trap with the thermal emission activation energy of 0.15 eV was considered to correspond to the divacancy. Although the clustered nature of the defects was observed, PICTS measurements suggest that the material state of high-resistivity NTD silicon is still crystalline and not amorphous. (author)

  2. Transient interaction model of electromagnetic field generated by lightning current pulses and human body

    International Nuclear Information System (INIS)

    Iváncsy, T; Kiss, I; Tamus, Z Á; Szücs, L

    2015-01-01

    The lightning current generates time-varying magnetic field near the down-conductor and the down-conductors are mounted on the wall of the buildings where residential places might be situated. It is well known that the rapidly changing magnetic fields can generate dangerous eddy currents in the human body.The higher duration and gradient of the magnetic field can cause potentially life threatening cardiac stimulation. The coupling mechanism between the electromagnetic field and the human body is based on a well-known physical phenomena (e.g. Faradays law of induction). However, the calculation of the induced current is very complicated because the shape of the organs is complex and the determination of the material properties of living tissues is difficult, as well. Our previous study revealed that the cardiac stimulation is independent of the rising time of the lightning current and only the peak of the current counts.In this study, the authors introduce an improved model of the interaction of electromagnetic fields of lighting current near down-conductor and human body. Our previous models are based on the quasi stationer field calculations, the new improved model is a transient model. This is because the magnetic field around the down-conductor and in the human body can be determined more precisely, therefore the dangerous currents in the body can be estimated. (paper)

  3. Modeling of Single Event Transients With Dual Double-Exponential Current Sources: Implications for Logic Cell Characterization

    Science.gov (United States)

    Black, Dolores A.; Robinson, William H.; Wilcox, Ian Z.; Limbrick, Daniel B.; Black, Jeffrey D.

    2015-08-01

    Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. An accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventional model based on one double-exponential source can be incomplete. A small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. The parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.

  4. PC operated acoustic transient spectroscopy of deep levels in MIS structures

    International Nuclear Information System (INIS)

    Bury, P.; Jamnicky, I.

    1996-01-01

    A new version of acoustic deep-level transient spectroscopy is presented to study the traps at the insulator-semiconductor interface. The acoustic deep-level transient spectroscopy uses an acoustoelectric response signal produced by the MIS structure interface when a longitudinal acoustic wave propagates through a structure. The acoustoelectric response signal is extremely sensitive to external conditions of the structure and reflects any changes in the charge distribution, connected also with charged traps. In comparison with previous version of acoustic deep-level transient spectroscopy that closely coincides with the principle of the original deep-level transient spectroscopy technique, the present technique is based on the computer-evaluated isothermal transients and represents an improved, more efficient and time saving technique. Many tests on the software used for calculation as well as on experimental setup have been performed. The improved acoustic deep-level transient spectroscopy method has been applied for the Si(p) MIS structures. The deep-level parameters as activation energy and capture cross-section have been determined. (authors)

  5. Switching transients in a superconducting coil

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1983-01-01

    A study is made of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to performance tests on the MFTF Yin-yang coils. It is found that the breaker opening time is the critical factor in determining the size and shape of the transient. Instantaneous opening of the breaker causes a lightly damped transient with large amplitude voltages to ground. Increasing the opening time causes the transient to become a monopulse of decreasing amplitude. The voltages at the external terminals are determined by the parameters of the external circuit. For fast opening times the frequency depends on the dump resistor inductance, the circuit capacitance, and the amplitude on the coil current. For slower openings the dump resistor inductance and the current determine the amplitude of the voltage to ground at the terminals. Voltages to ground are less in the interior of the coil, where transients related to the parameters of the coil itself are observed

  6. Investigation of Thermal Interface Materials Using Phase-Sensitive Transient Thermoreflectance Technique: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Feng, X.; King, C.; DeVoto, D.; Mihalic, M.; Narumanchi, S.

    2014-08-01

    With increasing power density in electronics packages/modules, thermal resistances at multiple interfaces are a bottleneck to efficient heat removal from the package. In this work, the performance of thermal interface materials such as grease, thermoplastic adhesives and diffusion-bonded interfaces are characterized using the phase-sensitive transient thermoreflectance technique. A multi-layer heat conduction model was constructed and theoretical solutions were derived to obtain the relation between phase lag and the thermal/physical properties. This technique enables simultaneous extraction of the contact resistance and bulk thermal conductivity of the TIMs. With the measurements, the bulk thermal conductivity of Dow TC-5022 thermal grease (70 to 75 um bondline thickness) was 3 to 5 W/(m-K) and the contact resistance was 5 to 10 mm2-K/W. For the Btech thermoplastic material (45 to 80 μm bondline thickness), the bulk thermal conductivity was 20 to 50 W/(m-K) and the contact resistance was 2 to 5 mm2-K/W. Measurements were also conducted to quantify the thermal performance of diffusion-bonded interface for power electronics applications. Results with the diffusion-bonded sample showed that the interfacial thermal resistance is more than one order of magnitude lower than those of traditional TIMs, suggesting potential pathways to efficient thermal management.

  7. Calcium currents in a fast-twitch skeletal muscle of the rat

    OpenAIRE

    1983-01-01

    Slow ionic currents were measured in the rat omohyoid muscle with the three-microelectrode voltage-clamp technique. Sodium and delayed rectifier potassium currents were blocked pharmacologically. Under these conditions, depolarizing test pulses elicited an early outward current, followed by a transient slow inward current, followed in turn by a late outward current. The early outward current appeared to be a residual delayed rectifier current. The slow inward current was identified as a calci...

  8. Hybrid finite difference/finite element solution method development for non-linear superconducting magnet and electrical circuit breakdown transient analysis

    International Nuclear Information System (INIS)

    Kraus, H.G.; Jones, J.L.

    1986-01-01

    The problem of non-linear superconducting magnet and electrical protection circuit system transients is formulated. To enable studying the effects of coil normalization transients, coil distortion (due to imbalanced magnetic forces), internal coil arcs and shorts, and other normal and off-normal circuit element responses, the following capabilities are included: temporal, voltage and current-dependent voltage sources, current sources, resistors, capacitors and inductors. The concept of self-mutual inductance, and the form of the associated inductance matrix, is discussed for internally shorted coils. This is a Kirchhoff's voltage loop law and Kirchhoff's current node law formulation. The non-linear integrodifferential equation set is solved via a unique hybrid finite difference/integral finite element technique. (author)

  9. Transient Stability Improvement for Combined Heat and Power System Using Load Shedding

    Directory of Open Access Journals (Sweden)

    Hung-Cheng Chen

    2014-01-01

    Full Text Available The purpose of the paper is to analyze and improve the transient stability of an industrial combined heat and power (CHP system in a high-tech science park in Taiwan. The CHP system installed two 161 kV/161 kV high-impendence transformers to connect with Taipower System (TPS for both decreasing the short-circuit fault current and increasing the fault critical clearing time. The transient stabilities of three types of operation modes in CHP units, 3G1S, 2G1S, and 1G1S, are analyzed. Under the 3G1S operation mode, the system frequency is immediately restored to 60 Hz after tie line tripping with the TPS. Under the 1G1S and 2G1S operation modes, the system frequencies will continuously decrease and eventually become unstable. A novel transient stability improvement approach using load shedding technique based on the change in frequency is proposed to improve the transient stability.

  10. Applications of transient annealing to solar cell processing

    Energy Technology Data Exchange (ETDEWEB)

    Bentini, G.G. (C.N.R. Istituto LAMEL, Bologna (Italy))

    1983-01-01

    The economical reasons supporting the introduction of transient annealing in solar cell manufacturing are briefly discussed. Such techniques may play an important role, as they are compatible with the request of high throughput, automated processing together with the high quality of the p-n junction which are necessary for large scale economical production of photovoltaic energy. A survey of the applications of the different transient annealing techniques to solar cell processing has been developed by comparing in detail the results obtained up to now the case of solid and liquid phase transient annealing, associated with dry techniques such as Ion Implantation or dopant deposition on the wafer surface. The possibility of using laser pulses for the formation of the p-n junction by incorporation of dopant atoms from a suitable gaseous environment, has also been examined.

  11. Large scale applicability of a Fully Adaptive Non-Intrusive Spectral Projection technique: Sensitivity and uncertainty analysis of a transient

    International Nuclear Information System (INIS)

    Perkó, Zoltán; Lathouwers, Danny; Kloosterman, Jan Leen; Hagen, Tim van der

    2014-01-01

    Highlights: • Grid and basis adaptive Polynomial Chaos techniques are presented for S and U analysis. • Dimensionality reduction and incremental polynomial order reduce computational costs. • An unprotected loss of flow transient is investigated in a Gas Cooled Fast Reactor. • S and U analysis is performed with MC and adaptive PC methods, for 42 input parameters. • PC accurately estimates means, variances, PDFs, sensitivities and uncertainties. - Abstract: Since the early years of reactor physics the most prominent sensitivity and uncertainty (S and U) analysis methods in the nuclear community have been adjoint based techniques. While these are very effective for pure neutronics problems due to the linearity of the transport equation, they become complicated when coupled non-linear systems are involved. With the continuous increase in computational power such complicated multi-physics problems are becoming progressively tractable, hence affordable and easily applicable S and U analysis tools also have to be developed in parallel. For reactor physics problems for which adjoint methods are prohibitive Polynomial Chaos (PC) techniques offer an attractive alternative to traditional random sampling based approaches. At TU Delft such PC methods have been studied for a number of years and this paper presents a large scale application of our Fully Adaptive Non-Intrusive Spectral Projection (FANISP) algorithm for performing the sensitivity and uncertainty analysis of a Gas Cooled Fast Reactor (GFR) Unprotected Loss Of Flow (ULOF) transient. The transient was simulated using the Cathare 2 code system and a fully detailed model of the GFR2400 reactor design that was investigated in the European FP7 GoFastR project. Several sources of uncertainty were taken into account amounting to an unusually high number of stochastic input parameters (42) and numerous output quantities were investigated. The results show consistently good performance of the applied adaptive PC

  12. Current STR-based techniques in forensic science

    Directory of Open Access Journals (Sweden)

    Phuvadol Thanakiatkrai

    2013-01-01

    Full Text Available DNA analysis in forensic science is mainly based on short tandem repeat (STR genotyping. The conventional analysis is a three-step process of DNA extraction, amplification and detection. An overview of various techniques that are currently in use and are being actively researched for STR typing is presented. The techniques are separated into STR amplification and detection. New techniques for forensic STR analysis focus on increasing sensitivity, resolution and discrimination power for suboptimal samples. These are achieved by shifting primer-binding sites, using high-fidelity and tolerant polymerases and applying novel methods to STR detection. Examples in which STRs are used in criminal investigations are provided and future research directions are discussed.

  13. Ion transfer through solvent polymeric membranes driven by an exponential current flux.

    Science.gov (United States)

    Molina, A; Torralba, E; González, J; Serna, C; Ortuño, J A

    2011-03-21

    General analytical equations which govern ion transfer through liquid membranes with one and two polarized interfaces driven by an exponential current flux are derived. Expressions for the transient and stationary E-t, dt/dE-E and dI/dE-E curves are obtained, and the evolution from transient to steady behaviour has been analyzed in depth. We have also shown mathematically that the voltammetric and stationary chronopotentiometric I(N)-E curves are identical (with E being the applied potential for voltammetric techniques and the measured potential for chronopotentiometric techniques), and hence, their derivatives provide identical information.

  14. Transient two-phase flow

    International Nuclear Information System (INIS)

    Hsu, Y.Y.

    1974-01-01

    The following papers related to two-phase flow are summarized: current assumptions made in two-phase flow modeling; two-phase unsteady blowdown from pipes, flow pattern in Laval nozzle and two-phase flow dynamics; dependence of radial heat and momentum diffusion; transient behavior of the liquid film around the expanding gas slug in a vertical tube; flooding phenomena in BWR fuel bundles; and transient effects in bubble two-phase flow. (U.S.)

  15. Quantitative pulsed eddy current analysis

    International Nuclear Information System (INIS)

    Morris, R.A.

    1975-01-01

    The potential of pulsed eddy current testing for furnishing more information than conventional single-frequency eddy current methods has been known for some time. However, a fundamental problem has been analyzing the pulse shape with sufficient precision to produce accurate quantitative results. Accordingly, the primary goal of this investigation was to: demonstrate ways of digitizing the short pulses encountered in PEC testing, and to develop empirical analysis techniques that would predict some of the parameters (e.g., depth) of simple types of defect. This report describes a digitizing technique using a computer and either a conventional nuclear ADC or a fast transient analyzer; the computer software used to collect and analyze pulses; and some of the results obtained. (U.S.)

  16. ASGARD: A LARGE SURVEY FOR SLOW GALACTIC RADIO TRANSIENTS. I. OVERVIEW AND FIRST RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Peter K. G.; Bower, Geoffrey C.; Croft, Steve; Keating, Garrett K.; Law, Casey J.; Wright, Melvyn C. H., E-mail: pwilliams@astro.berkeley.edu [Department of Astronomy, B-20 Hearst Field Annex 3411, University of California, Berkeley, CA 94720-3411 (United States)

    2013-01-10

    Searches for slow radio transients and variables have generally focused on extragalactic populations, and the basic parameters of Galactic populations remain poorly characterized. We present a large 3 GHz survey performed with the Allen Telescope Array (ATA) that aims to improve this situation: ASGARD, the ATA Survey of Galactic Radio Dynamism. ASGARD observations spanned two years with weekly visits to 23 deg{sup 2} in two fields in the Galactic plane, totaling 900 hr of integration time on science fields and making it significantly larger than previous efforts. The typical blind unresolved source detection limit was 10 mJy. We describe the observations and data analysis techniques in detail, demonstrating our ability to create accurate wide-field images while effectively modeling and subtracting large-scale radio emission, allowing standard transient-and-variability analysis techniques to be used. We present early results from the analysis of two pointings: one centered on the microquasar Cygnus X-3 and one overlapping the Kepler field of view (l = 76 Degree-Sign , b = +13. Degree-Sign 5). Our results include images, catalog statistics, completeness functions, variability measurements, and a transient search. Out of 134 sources detected in these pointings, the only compellingly variable one is Cygnus X-3, and no transients are detected. We estimate number counts for potential Galactic radio transients and compare our current limits to previous work and our projection for the fully analyzed ASGARD data set.

  17. Heavy Ion Current Transients in SiGe HBTs

    Science.gov (United States)

    Pellish, Jonathan A.; Reed, Robert A.; Vizkelethy, Gyorgy; McMorrow, Dale; Ferlet-Cavrois, Veronique; Baggio, Jacques; Paillet, Philipe; Duhanel, Olivier; Phillips, Stanley D.; Sutton, Akil K.; hide

    2009-01-01

    Time-resolved ion beam induced charge reveals heavy ion response of IBM 5AM SiGe HBT: a) Position correlation[ b) Unique response for different bias schemes; c) Similarities to TPA pulsed-laser data. Heavy ion broad-beam transients provide more realistic device response: a) Feedback using microbeam data; b) Overcome issues of LET and ion range with microbeam. Both micro- and broad-beam data sets yield valuable input for TCAD simulations. Uncover detailed mechanisms for SiGe HBTs and other devices fabricated on lightly-doped substrates.

  18. Research on generation mechanism of single event transient current generated in the semiconductor using ion accelerator

    International Nuclear Information System (INIS)

    Hirao, Toshio

    2007-01-01

    Single-event upset (SEU) is triggered when an amount of electric charges induced by energetic ion incidence exceeds a value known as a critical charge in a very short time period. Therefore, accurate evaluation of electric charge and understanding of basic mechanism of SEU are necessary for the improvement of SEU torrance of electronic devices. In this paper, the collected charges for the single event transient current induced on semiconductor by heavy ion microbeams, and application to use microbeam for single event studies are presented. (author)

  19. Transient magnetic currents through a molecular bridge: limits to reduction of non-equilibrium Green's functions to a generalized master equation

    Czech Academy of Sciences Publication Activity Database

    Kalvová, Anděla; Velický, B.; Špička, Václav

    2017-01-01

    Roč. 30, č. 3 (2017), s. 807-811 ISSN 1557-1939 Institutional support: RVO:68378271 Keywords : non-equilibrium * initial conditions * transient currents * molecular islands Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 1.180, year: 2016

  20. Spherical Indentation Techniques for Creep Property Evaluation Considering Transient Creep

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Dongkyu; Kim, Minsoo; Lee, Hyungyil [Sogang Univ., Seoul, (Korea, Republic of); Lee, Jin Haeng [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-11-15

    Creep through nanoindentations has attracted increasing research attention in recent years. Many studies related to indentation creep tests, however, have simply focused on the characteristics of steady-state creep, and there exist wide discrepancies between the uniaxial test and the indentation test. In this study, we performed a computational simulation of spherical indentations, and we proposed a method for evaluating the creep properties onsidering transient creep. We investigated the material behavior with variation of creep properties and expressed it using regression equations for normalized variables. We finally developed a program to evaluate the creep properties considering transient creep. By using the proposed method, we successfully obtained creep exponents with an average error less than 1.1 and creep coefficients with an average error less than 2.3 from the load-depth curve.

  1. Spherical Indentation Techniques for Creep Property Evaluation Considering Transient Creep

    International Nuclear Information System (INIS)

    Lim, Dongkyu; Kim, Minsoo; Lee, Hyungyil; Lee, Jin Haeng

    2013-01-01

    Creep through nanoindentations has attracted increasing research attention in recent years. Many studies related to indentation creep tests, however, have simply focused on the characteristics of steady-state creep, and there exist wide discrepancies between the uniaxial test and the indentation test. In this study, we performed a computational simulation of spherical indentations, and we proposed a method for evaluating the creep properties onsidering transient creep. We investigated the material behavior with variation of creep properties and expressed it using regression equations for normalized variables. We finally developed a program to evaluate the creep properties considering transient creep. By using the proposed method, we successfully obtained creep exponents with an average error less than 1.1 and creep coefficients with an average error less than 2.3 from the load-depth curve

  2. Radiotherapy in prostate cancer. Innovative techniques and current controversies

    International Nuclear Information System (INIS)

    Geinitz, Hans

    2015-01-01

    Examines in detail the role of innovative radiation techniques in the management of prostate cancer, including IMRT, IGRT, BART, and modern brachytherapy. Explores a range of current controversies in patient treatment. Intended for both radiation oncologists and urologists. Radiation treatment is rapidly evolving owing to the coordinated research of physicists, engineers, computer and imaging specialists, and physicians. Today, the arsenal of ''high-precision'' or ''targeted'' radiotherapy includes multimodal imaging, in vivo dosimetry, Monte Carlo techniques for dose planning, patient immobilization techniques, intensity-modulated radiotherapy (IMRT), image-guided radiotherapy (IGRT), biologically adapted radiotherapy (BART), quality assurance methods, novel methods of brachytherapy, and, at the far end of the scale, particle beam radiotherapy using protons and carbon ions. These approaches are like pieces of a puzzle that need to be put together to provide the prostate cancer patient with high-level optimized radiation treatment. This book examines in detail the role of the above-mentioned innovative radiation techniques in the management of prostate cancer. In addition, a variety of current controversies regarding treatment are carefully explored, including whether prophylactic treatment of the pelvic lymphatics is essential, the magnitude of the effect of dose escalation, whether a benefit accrues from hypofractionation, and what evidence exists for the superiority of protons or heavy ions. Radiotherapy in Prostate Cancer: Innovative Techniques and Current Controversies is intended for both radiation oncologists and urologists with an interest in the up-to-date capabilities of modern radiation oncology for the treatment of prostate cancer.

  3. Compact high-current, subnanosecond electron accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shpak, V G; Shunajlov, S A; Ulmaskulov, M R; Yalandin, M I [Russian Academy of Sciences, Ekaterinburg (Russian Federation). Inst. of Electrophysics; Pegel, I V [Russian Academy of Sciences, Tomsk (Russian Federation). High-Current Electronics Inst.; Tarakanov, V P [Russian Academy of Sciences, Moscow (Russian Federation). High-Temperature Inst.

    1997-12-31

    A compact subnanosecond, high-current electron accelerator producing an annular electron beam of duration up to 300 - 400 ps, energy about 250 keV, and current up to 1 kA has been developed to study transient processes in pulsed power microwave devices. The measuring and recording techniques used to experimentally investigate the dynamics of the beam current pulse and the transformation of the electron energy during the transportation of the beam in a longitudinal magnetic field are described. The experimental data obtained are compared with the predictions of a numerical simulation. (author). 6 figs., 5 refs.

  4. Experimental investigation of the effect of titanium dioxide and barium titanate additives on DC transient currents in low density polyethylene

    DEFF Research Database (Denmark)

    Khalil, M.S; Henk, Peter O; Henriksen, Mogens

    1988-01-01

    The effect of titanium dioxide as a semiconductive additive and barium titanate as a highly polar additive on the DC transient currents in low-density polyethylene is investigated. Experiments were made using thick specimens under a high electric field (>25×106 V/m) and a constant temperature of 40...

  5. Machine monitoring via current signature analysis techniques

    International Nuclear Information System (INIS)

    Smith, S.F.; Castleberry, K.N.; Nowlin, C.H.

    1992-01-01

    A significant need in the effort to provide increased production quality is to provide improved plant equipment monitoring capabilities. Unfortunately, in today's tight economy, even such monitoring instrumentation must be implemented in a recognizably cost effective manner. By analyzing the electric current drawn by motors, actuator, and other line-powered industrial equipment, significant insights into the operations of the movers, driven equipment, and even the power source can be obtained. The generic term 'current signature analysis' (CSA) has been coined to describe several techniques for extracting useful equipment or process monitoring information from the electrical power feed system. A patented method developed at Oak Ridge National Laboratory is described which recognizes the presence of line-current modulation produced by motors and actuators driving varying loads. The in-situ application of applicable linear demodulation techniques to the analysis of numerous motor-driven systems is also discussed. The use of high-quality amplitude and angle-demodulation circuitry has permitted remote status monitoring of several types of medium and high-power gas compressors in (US DOE facilities) driven by 3-phase induction motors rated from 100 to 3,500 hp, both with and without intervening speed increasers. Flow characteristics of the compressors, including various forms of abnormal behavior such as surging and rotating stall, produce at the output of the specialized detectors specific time and frequency signatures which can be easily identified for monitoring, control, and fault-prevention purposes. The resultant data are similar in form to information obtained via standard vibration-sensing techniques and can be analyzed using essentially identical methods. In addition, other machinery such as refrigeration compressors, brine pumps, vacuum pumps, fans, and electric motors have been characterized

  6. Calcium Transient and Sodium-Calcium Exchange Current in Human versus Rabbit Sinoatrial Node Pacemaker Cells

    Directory of Open Access Journals (Sweden)

    Arie O. Verkerk

    2013-01-01

    Full Text Available There is an ongoing debate on the mechanism underlying the pacemaker activity of sinoatrial node (SAN cells, focusing on the relative importance of the “membrane clock” and the “Ca2+ clock” in the generation of the small net membrane current that depolarizes the cell towards the action potential threshold. Specifically, the debate centers around the question whether the membrane clock-driven hyperpolarization-activated current, If, which is also known as the “funny current” or “pacemaker current,” or the Ca2+ clock-driven sodium-calcium exchange current, INaCa, is the main contributor to diastolic depolarization. In our contribution to this journal’s “Special Issue on Cardiac Electrophysiology,” we present a numerical reconstruction of If and INaCa in isolated rabbit and human SAN pacemaker cells based on experimental data on action potentials, If, and intracellular calcium concentration ([Ca2+]i that we have acquired from these cells. The human SAN pacemaker cells have a smaller If, a weaker [Ca2+]i transient, and a smaller INaCa than the rabbit cells. However, when compared to the diastolic net membrane current, INaCa is of similar size in human and rabbit SAN pacemaker cells, whereas If is smaller in human than in rabbit cells.

  7. Molecular aspects of adrenergic modulation of the transient outward current

    NARCIS (Netherlands)

    van der Heyden, Marcel A. G.; Wijnhoven, Tessa J. M.; Opthof, Tobias

    2006-01-01

    Transient outward channels have a different impact on action potential configuration in small mammals compared to large mammals. Small mammals depend primarily on Ito1 for repolarization, while in larger animals Ito1 only indirectly determines action potential duration by setting the level of the

  8. An appraisal of computational techniques for transient heat conduction equation

    International Nuclear Information System (INIS)

    Kant, T.

    1983-01-01

    A semi-discretization procedure in which the ''space'' dimension is discretized by the finite element method is emphasized for transient problems. This standard methodology transforms the space-time partial differential equation (PDE) system into a set of ordinary differential equations (ODE) in time. Existing methods for transient heat conduction calculations are then reviewed. Existence of two general classes of time integration schemes- implicit and explicit is noted. Numerical stability characteristics of these two methods are elucidated. Implicit methods are noted to be numerically stable, permitting large time steps, but the cost per step is high. On the otherhand, explicit schemes are noted to be inexpensive per step, but small step size is required. Low computational cost of the explicit schemes make it very attractive for nonlinear problems. However, numerical stability considerations requiring use of very small time steps come in the way of its general adoption. Effectiveness of the fourth-order Runge-Kutta-Gill explicit integrator is then numerically evaluated. Finally we discuss some very recent works on development of computational algorithms which not only achieve unconditional stability, high accuracy and convergence but involve computations on matrix equations of elements only. This development is considered to be very significant in the light of our experience gained for simple heat conduction calculations. We conclude that such algorithms have the potential for further developments leading to development of economical methods for general transient analysis of complex physical systems. (orig.)

  9. Electromagnetic considerations for RF current density imaging [MRI technique].

    Science.gov (United States)

    Scott, G C; Joy, M G; Armstrong, R L; Henkelman, R M

    1995-01-01

    Radio frequency current density imaging (RF-CDI) is a recent MRI technique that can image a Larmor frequency current density component parallel to B(0). Because the feasibility of the technique was demonstrated only for homogeneous media, the authors' goal here is to clarify the electromagnetic assumptions and field theory to allow imaging RF currents in heterogeneous media. The complete RF field and current density imaging problem is posed. General solutions are given for measuring lab frame magnetic fields from the rotating frame magnetic field measurements. For the general case of elliptically polarized fields, in which current and magnetic field components are not in phase, one can obtain a modified single rotation approximation. Sufficient information exists to image the amplitude and phase of the RF current density parallel to B(0) if the partial derivative in the B(0) direction of the RF magnetic field (amplitude and phase) parallel to B(0) is much smaller than the corresponding current density component. The heterogeneous extension was verified by imaging conduction and displacement currents in a phantom containing saline and pure water compartments. Finally, the issues required to image eddy currents are presented. Eddy currents within a sample will distort both the transmitter coil reference system, and create measurable rotating frame magnetic fields. However, a three-dimensional electro-magnetic analysis will be required to determine how the reference system distortion affects computed eddy current images.

  10. Effect of trapped electrons on the transient current density and luminance of organic light-emitting diode

    Science.gov (United States)

    Lee, Jiun-Haw; Chen, Chia-Hsun; Lin, Bo-Yen; Shih, Yen-Chen; Lin, King-Fu; Wang, Leeyih; Chiu, Tien-Lung; Lin, Chi-Feng

    2018-04-01

    Transient current density and luminance from an organic light-emitting diode (OLED) driven by voltage pulses were investigated. Waveforms with different repetition rate, duty cycle, off-period, and on-period were used to study the injection and transport characteristics of electron and holes in an OLED under pulse operation. It was found that trapped electrons inside the emitting layer (EML) and the electron transporting layer (ETL) material, tris(8-hydroxyquinolate)aluminum (Alq3) helped for attracting the holes into the EML/ETL and reducing the driving voltage, which was further confirmed from the analysis of capacitance-voltage and displacement current measurement. The relaxation time and trapped filling time of the trapped electrons in Alq3 layer were ~200 µs and ~600 µs with 6 V pulse operation, respectively.

  11. Compensation techniques for operational amplifier bias current

    International Nuclear Information System (INIS)

    Silva, M.S.

    1981-01-01

    Two techniques are proposed for the compensation of the input current on operational amplifiers that can be used on inverting and non-inverting configurations. A qualitative analysis of temperature drift problems is made, and as a practical application, the construction of a voltage follower for high impedance measurements is presented. (Author) [pt

  12. Voltage transients in thin-film InSb Hall sensor

    Science.gov (United States)

    Bardin, Alexey; Ignatjev, Vyacheslav; Orlov, Andrey; Perchenko, Sergey

    The work is reached to study temperature transients in thin-film Hall sensors. We experimentally study InSb thin-film Hall sensor. We find transients of voltage with amplitude about 10 μ V on the sensor ports after current switching. We demonstrate by direct measurements that the transients is caused by thermo-e.m.f., and both non-stationarity and heterogeneity of temperature in the film. We find significant asymmetry of temperature field for different direction of the current, which is probably related to Peltier effect. The result can be useful for wide range of scientist who works with switching of high density currents in any thin semiconductor films.

  13. Radiotherapy in prostate cancer. Innovative techniques and current controversies

    Energy Technology Data Exchange (ETDEWEB)

    Geinitz, Hans [Krankenhaus der Barmherzigen Schwestern, Linz (Austria). Dept. of Radiation Oncology; Linz Univ. (Austria). Medical Faculty; Roach, Mack III [California Univ., San Francisco, CA (United States). Dept. of Radiation Oncology; Van As, Nicholas (ed.) [The Institute of Cancer Research, Sutton Surrey (United Kingdom)

    2015-04-01

    Examines in detail the role of innovative radiation techniques in the management of prostate cancer, including IMRT, IGRT, BART, and modern brachytherapy. Explores a range of current controversies in patient treatment. Intended for both radiation oncologists and urologists. Radiation treatment is rapidly evolving owing to the coordinated research of physicists, engineers, computer and imaging specialists, and physicians. Today, the arsenal of ''high-precision'' or ''targeted'' radiotherapy includes multimodal imaging, in vivo dosimetry, Monte Carlo techniques for dose planning, patient immobilization techniques, intensity-modulated radiotherapy (IMRT), image-guided radiotherapy (IGRT), biologically adapted radiotherapy (BART), quality assurance methods, novel methods of brachytherapy, and, at the far end of the scale, particle beam radiotherapy using protons and carbon ions. These approaches are like pieces of a puzzle that need to be put together to provide the prostate cancer patient with high-level optimized radiation treatment. This book examines in detail the role of the above-mentioned innovative radiation techniques in the management of prostate cancer. In addition, a variety of current controversies regarding treatment are carefully explored, including whether prophylactic treatment of the pelvic lymphatics is essential, the magnitude of the effect of dose escalation, whether a benefit accrues from hypofractionation, and what evidence exists for the superiority of protons or heavy ions. Radiotherapy in Prostate Cancer: Innovative Techniques and Current Controversies is intended for both radiation oncologists and urologists with an interest in the up-to-date capabilities of modern radiation oncology for the treatment of prostate cancer.

  14. Self Referencing Heterodyne Transient Grating Spectroscopy with Short Wavelength

    Directory of Open Access Journals (Sweden)

    Jakob Grilj

    2015-04-01

    Full Text Available Heterodyning by a phase stable reference electric field is a well known technique to amplify weak nonlinear signals. For short wavelength, the generation of a reference field in front of the sample is challenging because of a lack of suitable beamsplitters. Here, we use a permanent grating which matches the line spacing of the transient grating for the creation of a phase stable reference field. The relative phase among the two can be changed by a relative translation of the permanent and transient gratings in direction orthogonal to the grating lines. We demonstrate the technique for a transient grating on a VO2 thin film and observe constructive as well as destructive interference signals.

  15. Investigation on Capacitor Switching Transient Limiter with a Three phase Variable Resistance

    DEFF Research Database (Denmark)

    Naderi, Seyed Behzad; Jafari, Mehdi; Zandnia, Amir

    2017-01-01

    In this paper, a capacitor switching transient limiter based on a three phase variable resistance is proposed. The proposed structure eliminates the capacitor switching transient current and over-voltage by introducing a variable resistance to the current path with its special switching pattern...... transients on capacitor after bypassing. Analytic Analyses for this structure in transient cases are presented in details and simulations are performed by MATLAB software to prove its effectiveness....

  16. Transient analysis of multicavity klystrons

    International Nuclear Information System (INIS)

    Lavine, T.L.; Miller, R.H.; Morton, P.L.; Ruth, R.D.

    1988-09-01

    We describe a model for analytic analysis of transients in multicavity klystron output power and phase. Cavities are modeled as resonant circuits, while bunching of the beam is modeled using linear space-charge wave theory. Our analysis has been implemented in a computer program which we use in designing multicavity klystrons with stable output power and phase. We present as examples transient analysis of a relativistic klystron using a magnetic pulse compression modulator, and of a conventional klystron designed to use phase shifting techniques for RF pulse compression. 4 refs., 4 figs

  17. The formation of metallic plasmas in transient capillary discharges at high current

    International Nuclear Information System (INIS)

    Wyndham, E S; Favre, M; Aliaga-Rossel, R

    2006-01-01

    We report observations of the formation of a metallic plasma in a high aspect ratio z-pinch confined within a ceramic capillary. A series of experiments on different capillary geometries was undertaken in which titanium metal rings were used to promote the formation of a titanium plasma through preferential ablation. In an initial vacuum a titanium seed plasma is formed in the hollow cathode (HC) volume by a low energy laser spark. This pre-ionizing plasma is assisted in its expansion into the z-pinch volume by the electron beams generated by a pre-ionizing discharge in the capillary, due to the HC effect. Further intense e-beam activity occurs on applying the main driver current to the capillary electrodes before the discharge impedance abruptly drops to give rise to an ensuing high current z-pinch. A segmented titanium ring structure within the capillary promotes metal ablation. The discharges are performed in tubes of 60 to 110 mm length and 3 and 5 mm effective internal diameter. The main discharge current is provided from a small pulsed power switched coaxial line, at up to 150 kA. The generator may be configured to deliver two different rates of current rise and this is found to have a significant effect on the plasma dynamics. The plasma properties are obtained from observations of the axial x-ray emission. The diagnostics used are filtered Si diodes, filtered time-resolved multi-pinhole camera images and the time resolved soft x-ray spectrum from 3 to 20 nm. While a single species metal plasma is not obtained, a very significant proportion of Ti is achieved in the higher rate of current rise configuration. The fraction of Ti diminishes for the longest length discharges and for the larger diameter tube diameter, as does the observed z-pinch uniformity. There is a weak dependance of the electron temperature with tube geometry, but the plasma density falls substantially in the longer discharges. This coincides with diminished effectiveness of the transient HC

  18. Searching for MHz Transients with the VLA Low-band Ionosphere and Transient Experiment (VLITE)

    Science.gov (United States)

    Polisensky, Emil; Peters, Wendy; Giacintucci, Simona; Clarke, Tracy; Kassim, Namir E.; hyman, Scott D.; van der Horst, Alexander; Linford, Justin; Waldron, Zach; Frail, Dale

    2018-01-01

    NRL and NRAO have expanded the low frequency capabilities of the VLA through the VLA Low-band Ionosphere and Transient Experiment (VLITE, http://vlite.nrao.edu/ ), effectively making the instrument two telescopes in one. VLITE is a commensal observing system that harvests data from the prime focus in parallel with normal Cassegrain focus observing on a subset of VLA antennas. VLITE provides over 6000 observing hours per year in a > 5 square degree field-of-view using 64 MHz bandwidth centered on 352 MHz. By operating in parallel, VLITE offers invaluable low frequency data to targeted observations of transient sources detected at higher frequencies. With arcsec resolution and mJy sensitivity, VLITE additionally offers great potential for blind searches of rarer radio-selected transients. We use catalog matching software on the imaging products from the daily astrophysics pipeline and the LOFAR Transients Pipeline (TraP) on repeated observations of the same fields to search for coherent and incoherent astronomical transients on timescales of a few seconds to years. We present the current status of the VLITE transient science program from its initial deployment on 10 antennas in November 2014 through its expansion to 16 antennas in the summer of 2017. Transient limits from VLITE’s first year of operation (Polisensky et al. 2016) are updated per the most recent analysis.

  19. Review of HEDL fuel pin transient analyses analytical programs

    International Nuclear Information System (INIS)

    Scott, J.H.; Baars, R.E.

    1975-05-01

    Methods for analysis of transient fuel pin performance are described, as represented by the steady-state SIEX code and the PECT series of codes used for steady-state and transient mechanical analyses. The empirical fuel failure correlation currently in use for analysis of transient overpower accidents is described. (U.S.)

  20. The influence of internal current loop on transient response performance of I-V droop controlled paralleled DC-DC converters

    DEFF Research Database (Denmark)

    Wang, Haojie; Han, Minxiao; Guerrero, Josep M.

    2017-01-01

    The external droop control loop of I-V droop control is designed as a voltage loop with embedded virtual impedance, so the internal current loop plays a major role in the system bandwidth. Thus, in this paper, the influence of internal current loop on transient response performance of I-V droop...... controlled paralleled dc-dc converters is analyzed, which is guided and significant for its industry application. The model which is used for dynamic analysis is built, and the root locus method is used based on the model to analyze the dynamic response of the system by shifting different control parameters...

  1. Transient thermal camouflage and heat signature control

    Science.gov (United States)

    Yang, Tian-Zhi; Su, Yishu; Xu, Weikai; Yang, Xiao-Dong

    2016-09-01

    Thermal metamaterials have been proposed to manipulate heat flux as a new way to cloak or camouflage objects in the infrared world. To date, however, thermal metamaterials only operate in the steady-state and exhibit detectable, transient heat signatures. In this letter, the theoretical basis for a thermal camouflaging technique with controlled transient diffusion is presented. This technique renders an object invisible in real time. More importantly, the thermal camouflaging device instantaneously generates a pre-designed heat signature and behaves as a perfect thermal illusion device. A metamaterial coating with homogeneous and isotropic thermal conductivity, density, and volumetric heat capacity was fabricated and very good camouflaging performance was achieved.

  2. A modal method for transient thermal analysis of CANDU fuel channel

    International Nuclear Information System (INIS)

    Park, J-W.; Muzumdar, A.J.

    1996-01-01

    The classical modal expansion technique has been applied to predict transient fuel and coolant temperatures under on-power conditions in a CANDU fuel channel. The temperature profile across the fuel pellet is assumed to be parabolic and fuel and coolant temperatures are expanded with Fourier series. The coefficient derivatives are written in state space form and solved by the Runge-Kutta method of fifth order. To validate the present model, the calculated fuel temperatures for several sample cases were compared with HOTSPOT-II, which employs a more rigorous finite-difference model. The agreement was found to be reasonable for the operational transients simulated. The advantage of the modal method is the fast computation speed for application to the real-time system such as the CANDU simulator which is being currently developed at the Institute for Advanced Engineering (IAE). (author)

  3. Measurement of the magnetic moment of the 2$^{+}$ state in neutron-rich radioactive $^{72,74}$Zn using the transient field technique in inverse kinematics

    CERN Multimedia

    Kruecken, R; Speidel, K; Voulot, D; Neyens, G; Gernhaeuser, R A; Fraile prieto, L M; Leske, J

    We propose to measure the sign and magnitude of the g-factors of the first 2$^{+}$ states in radioactive neutron-rich $^{72,74}$Zn applying the transient field (TF) technique in inverse kinematics. The result of this experiment will allow to probe the $\

  4. Fault Diagnosis of Induction Machines in a Transient Regime Using Current Sensors with an Optimized Slepian Window

    Directory of Open Access Journals (Sweden)

    Jordi Burriel-Valencia

    2018-01-01

    Full Text Available The aim of this paper is to introduce a new methodology for the fault diagnosis of induction machines working in the transient regime, when time-frequency analysis tools are used. The proposed method relies on the use of the optimized Slepian window for performing the short time Fourier transform (STFT of the stator current signal. It is shown that for a given sequence length of finite duration, the Slepian window has the maximum concentration of energy, greater than can be reached with a gated Gaussian window, which is usually used as the analysis window. In this paper, the use and optimization of the Slepian window for fault diagnosis of induction machines is theoretically introduced and experimentally validated through the test of a 3.15-MW induction motor with broken bars during the start-up transient. The theoretical analysis and the experimental results show that the use of the Slepian window can highlight the fault components in the current’s spectrogram with a significant reduction of the required computational resources.

  5. Materials and processing approaches for foundry-compatible transient electronics

    Science.gov (United States)

    Chang, Jan-Kai; Fang, Hui; Bower, Christopher A.; Song, Enming; Yu, Xinge; Rogers, John A.

    2017-07-01

    Foundry-based routes to transient silicon electronic devices have the potential to serve as the manufacturing basis for “green” electronic devices, biodegradable implants, hardware secure data storage systems, and unrecoverable remote devices. This article introduces materials and processing approaches that enable state-of-the-art silicon complementary metal-oxide-semiconductor (CMOS) foundries to be leveraged for high-performance, water-soluble forms of electronics. The key elements are (i) collections of biodegradable electronic materials (e.g., silicon, tungsten, silicon nitride, silicon dioxide) and device architectures that are compatible with manufacturing procedures currently used in the integrated circuit industry, (ii) release schemes and transfer printing methods for integration of multiple ultrathin components formed in this way onto biodegradable polymer substrates, and (iii) planarization and metallization techniques to yield interconnected and fully functional systems. Various CMOS devices and circuit elements created in this fashion and detailed measurements of their electrical characteristics highlight the capabilities. Accelerated dissolution studies in aqueous environments reveal the chemical kinetics associated with the underlying transient behaviors. The results demonstrate the technical feasibility for using foundry-based routes to sophisticated forms of transient electronic devices, with functional capabilities and cost structures that could support diverse applications in the biomedical, military, industrial, and consumer industries.

  6. Applying inversion techniques to derive source currents and geoelectric fields for geomagnetically induced current calculations

    Directory of Open Access Journals (Sweden)

    J. S. de Villiers

    2014-10-01

    Full Text Available This research focuses on the inversion of geomagnetic variation field measurement to obtain source currents in the ionosphere. During a geomagnetic disturbance, the ionospheric currents create magnetic field variations that induce geoelectric fields, which drive geomagnetically induced currents (GIC in power systems. These GIC may disturb the operation of power systems and cause damage to grounded power transformers. The geoelectric fields at any location of interest can be determined from the source currents in the ionosphere through a solution of the forward problem. Line currents running east–west along given surface position are postulated to exist at a certain height above the Earth's surface. This physical arrangement results in the fields on the ground having the magnetic north and down components, and the electric east component. Ionospheric currents are modelled by inverting Fourier integrals (over the wavenumber of elementary geomagnetic fields using the Levenberg–Marquardt technique. The output parameters of the inversion model are the current strength, height and surface position of the ionospheric current system. A ground conductivity structure with five layers from Quebec, Canada, based on the Layered-Earth model is used to obtain the complex skin depth at a given angular frequency. This paper presents preliminary and inversion results based on these structures and simulated geomagnetic fields. The results show some interesting features in the frequency domain. Model parameters obtained through inversion are within 2% of simulated values. This technique has applications for modelling the currents of electrojets at the equator and auroral regions, as well as currents in the magnetosphere.

  7. Critical current measurement in superconducting rings using an automatic inductive technique

    International Nuclear Information System (INIS)

    Gonzalez-Jorge, H.; Linares, B.; Quelle, I.; Carballo, E.; Romani, L.; Domarco, G.

    2007-01-01

    A measurement technique was developed to identify the critical current of superconducting rings. It is based on the detection of the voltage on a secondary coil when the current induced in the superconductor by a primary one go beyond to the critical value. The technique uses a DC power supply to control the AC current circulating by the primary circuit. Such circuit mainly consists on an AC power supply which gives a constant AC voltage, a primary inducting coil and a control coil with iron core. The AC current circulating by this circuit is modified with the change in the impedance of the control coil due to the fact of the DC current supplied by the power supply in parallel with it

  8. Transient Performance Improvement Circuit (TPIC)s for DC-DC converter applications

    Science.gov (United States)

    Lim, Sungkeun

    Gordon Moore famously predicted the exponential increase in transistor integration and computing power that has been witnessed in recent decades [1]. In the near future, it is expected that more than one billion transistors will be integrated per chip, and advanced microprocessors will require clock speeds in excess of several GHz. The increasing number of transistors and high clock speeds will necessitate the consumption of more power. By 2014, it is expected that the maximum power consumption of the microprocessor will reach approximately 150W, and the maximum load current will be around 150A. Today's trend in power and thermal management is to reduce supply voltage as low as possible to reduce delivered power. It is anticipated that the Intel cores will operate on 0.8V of supply voltage by 2014 [2]. A significant challenge in Voltage Regulator Module (VRM) development for next generation microprocessors is to regulate the supply voltage within a certain tolerance band during high slew rate load transitions, since the required supply voltage tolerance band will be much narrower than the current requirement. If VR output impedance is maintained at a constant value from DC to high frequency, large output voltage spikes can be avoided during load cur- rent transients. Based on this, the Adaptive Voltage Position (AVP) concept was developed to achieve constant VR output impedance to improve transient response performance [3]. However, the VR output impedance can not be made constant over the entire frequency range with AVP design, because the AVP design makes the VR output impedance constant only at low frequencies. To make the output impedance constant at high frequencies, many bulk capacitors and ceramic capacitors are required. The tight supply voltage tolerance for the next generation of microprocessors during high slew rate load transitions requires fast transient response power supplies. A VRM can not follow the high slew rate load current transients, because

  9. Current research projects on traffic conflicts technique studies.

    NARCIS (Netherlands)

    Hondel, M. van den & and Kraay, J.H.

    1979-01-01

    A review of current research concerning the development, evaluation and use of the traffic conflicts technique is presented. The 32 studies, selected from the IRRD data base, are listed alphabetically by names of countries and under countries by names of research organizations. The IRRD descriptions

  10. Transient Phenomena in Multiphase and Multicomponent Systems: Research Report

    Science.gov (United States)

    Zur Beurteilung von Stoffen in der Landwirtschaft, Senatskommission

    2000-09-01

    Due to the reinforced risk and safety-analysis of industrial plants in chemical and energy-engineering there has been increased demand in industry for more information on thermo- and fluiddynamic effects of non-equilibria during strong transients. Therefore, the 'Deutsche Forschungsgemeinschaft' initiated a special research program focusing on the study of transient phenomena in multiphase systems with one or several components. This book describes macroscopic as well as microscopic transient situations. A large part of the book deals with numerical methods for describing transients in two-phase mixtures. New developments in measuring techniques are also presented.

  11. Eddy Current Thermography: System Development and Its Application in NDT

    International Nuclear Information System (INIS)

    Nurliyana Shamimie Rusli; Ilham Mukriz Zainal Abidin; Sidek, H.A.A.

    2015-01-01

    Eddy Current Thermography (ECT) is an integrative technique which combines eddy current and thermographic NDT in order to provide an efficient method for defect detection. The technique is applicable to electrically conductive material and has the ability to detect surface and subsurface defect. ECT is a non-contact technique; has the ability to provide instantaneous response and high scanning speed that makes it reliable for defect detection and assessment. The technique combines electromagnetic excitation of the work-piece via a coil carrying current, heating of the material by induction and inspection by transient infrared thermography. In this paper, the development of ECT system is detailed, including coil design for global and local heating of samples, and optimisation of excitation parameters (frequency, power, heating duration etc). Results from 3D FEM simulation and experimental investigations are also presented to provide the overview of underlying phenomena and application of ECT. The work demonstrates the effectiveness of the developed ECT system and technique in defect detection and assessment. (author)

  12. Use of plant operating history to define transient loads

    International Nuclear Information System (INIS)

    Dwivedy, K.K.

    1996-01-01

    Fatigue and crack growth analyses of components subjected to transient loads have been under continuous development during the recent past to include effects of environment on the components. The accuracy of the evaluation method on the predicted reliability of the components in the operating environment has become a focus of attention. Methods have integrated available material/component test data to improve evaluation techniques. However, in the area of definition of thermal transient loads the analyst still has to remain conservative, because no realistic guidelines have been developed to define thermal transients and their sequences. Fatigue re-evaluations of components are becoming increasingly necessary in operating plants as they age due to two reasons: (1) Components show age related degradation and cannot be repaired/replaced due to economic/logistic reasons. (2) Components experience transient conditions which were not considered in the original design. In either case, the evaluation of remaining life of components involves definition of transients and their sequence from the time the component was put in service until the end of life. As a common practice, initial plant design transients are used in a conservative definition of sequences to obtain results unrealistic for the situation, which sometimes leads to inaccurate estimate of the remaining life of components. The objective of this paper is to use plant operating history and plant monitoring data to provide procedures and techniques to define realistic transients for evaluation

  13. Transient current distributions in porous zinc electrodes in KOH electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Liu, M.B.; Yamazaki, Y.; Cook, G.M.; Yao, N.P.

    1981-02-01

    A zero-resistance ammeter circuit with a 10-channel operational amplifier was used to measure the current distribution during a discharge of 10 to 100 mA with simulated zinc porous electrodes in 7.24 M KOH saturated with ZnO. The reaction distribution was found to be highly nonuniform, with 70 to 78% of the charge transfer reaction completed in a depth of 0.01 cm. The high nonuniformity of the initial reaction profile was believed to be due to low conductivity of the electrolyte in the electrode pores. The current distribution changes during passivation of the electrode were experimentally obtained. A mathematical model based upon a macroscope averaging technique was used to predict the time dependence of charge transfer reaction profiles. With mathematical model, current distributions and overpotentials were predicted as a function of time for the segmented zinc electrode discharged at a current of 10 to 100 mA; for these predictions, assumed values of both precipitation rate constants for porous ZnO and diffusion coefficients for hydroxide and zincate ions were used. A gradual decrease in the specific conductivity of the pore electrolyte to 20% of the initial value during discharge yields predictions of current distributions and overpotentials in good agreement with the experimental data. The extent of reduction in the specific conductivity of the pore electrolyte implies a supersaturation of zincate of four times chemical saturation, which was been observed experimentally.At high discharge current (25 to 100 mA), the passivation behavior of the electrode has been simulated. The results of the experiments and mathematical model show that the effective reaction penetration depth is less than 0.02 cm.

  14. The role of ultrasound elastographic techniques in chronic liver disease: Current status and future perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Piscaglia, Fabio, E-mail: fabio.piscaglia@unibo.it [Division of Internal Medicine, University of Bologna, General and University Hospital S. Orsola-Malpighi, Bologna (Italy); Marinelli, Sara, E-mail: sara_marinelli@libero.it [Division of Internal Medicine, University of Bologna, General and University Hospital S. Orsola-Malpighi, Bologna (Italy); Bota, Simona, E-mail: bota_simona1982@yahoo.com [Department of Gastroenterology and Hepatology, University of Medicine and Pharmacy “Victor Babeş”, Timişoara (Romania); Serra, Carla, E-mail: carla.serra@aosp.bo.it [Division of Medical Liver Transplant Care, General and University Hospital S. Orsola-Malpighi, Bologna (Italy); Venerandi, Laura, E-mail: laura.venerandi@gmail.com [Division of Internal Medicine, University of Bologna, General and University Hospital S. Orsola-Malpighi, Bologna (Italy); Leoni, Simona, E-mail: leonisimona@yahoo.it [Division of Internal Medicine, University of Bologna, General and University Hospital S. Orsola-Malpighi, Bologna (Italy); Salvatore, Veronica, E-mail: veronica.salvatore@unibo.it [Division of Internal Medicine, University of Bologna, General and University Hospital S. Orsola-Malpighi, Bologna (Italy)

    2014-03-15

    This review illustrates the state of the art clinical applications and the future perspectives of ultrasound elastographic methods for the evaluation of chronic liver diseases, including the most widely used and validated technique, transient elastography, followed by shear wave elastography and strain imaging elastography. Liver ultrasound elastography allows the non-invasive evaluation of liver stiffness, providing information regarding the stage of fibrosis, comparable to liver biopsy which is still considered the gold standard; in this way, it can help physicians in managing patients, including the decision as to when to start antiviral treatment. The characterization of focal liver lesions and the prognostic role of the elastographic technique in the prediction of complications of cirrhosis are still under investigation.

  15. Application of a modified flux-coupling type superconducting fault current limiter to transient performance enhancement of micro-grid

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lei, E-mail: stclchen1982@163.com [School of Electrical Engineering, Wuhan University, Wuhan 430072 (China); Zheng, Feng; Deng, Changhong; Li, Shichun; Li, Miao; Liu, Hui [School of Electrical Engineering, Wuhan University, Wuhan 430072 (China); Zhu, Lin [Department of Electrical Engineering and Computer Science, University of Tennessee, Knoxville 37996 (United States); Guo, Fang [Department of Substation, Guang Dong Electric Power Design Institute, Guangzhou 510663 (China)

    2015-11-15

    Highlights: • A modified flux-coupling type SFCL is suggested to enhance the transient performance of a micro-grid. • The SFCL’s main contribution is to improve the micro-grid’s fault ride-through capability. • The SFCL also can make the micro-grid carry out a smooth transition between its grid-connected and islanded modes. • The simulations show that the SFCL can availably strengthen the micro-grid’s voltage and frequency stability. - Abstract: Concerning the application and development of a micro-grid system which is designed to accommodate high penetration of intermittent renewable resources, one of the main issues is related to an increase in the fault-current level. It is crucial to ensure the micro-grid’s operational stability and service reliability when a fault occurs in the main network. In this paper, our research group suggests a modified flux-coupling type superconducting fault current limiter (SFCL) to enhance the transient performance of a typical micro-grid system. The SFCL is installed at the point of common coupling (PCC) between the main network and the micro-grid, and it is expected to actively improve the micro-grid’s fault ride-through capability. And for some specific faults, the micro-grid should disconnect from the main network, and the SFCL’s contribution is to make the micro-grid carry out a smooth transition between its grid-connected and islanded modes. Related theory derivation, technical discussion and simulation analysis are performed. From the demonstrated results, applying the SFCL can effectively limit the fault current, maintain the power balance, and enhance the voltage and frequency stability of the micro-grid.

  16. Application of a modified flux-coupling type superconducting fault current limiter to transient performance enhancement of micro-grid

    International Nuclear Information System (INIS)

    Chen, Lei; Zheng, Feng; Deng, Changhong; Li, Shichun; Li, Miao; Liu, Hui; Zhu, Lin; Guo, Fang

    2015-01-01

    Highlights: • A modified flux-coupling type SFCL is suggested to enhance the transient performance of a micro-grid. • The SFCL’s main contribution is to improve the micro-grid’s fault ride-through capability. • The SFCL also can make the micro-grid carry out a smooth transition between its grid-connected and islanded modes. • The simulations show that the SFCL can availably strengthen the micro-grid’s voltage and frequency stability. - Abstract: Concerning the application and development of a micro-grid system which is designed to accommodate high penetration of intermittent renewable resources, one of the main issues is related to an increase in the fault-current level. It is crucial to ensure the micro-grid’s operational stability and service reliability when a fault occurs in the main network. In this paper, our research group suggests a modified flux-coupling type superconducting fault current limiter (SFCL) to enhance the transient performance of a typical micro-grid system. The SFCL is installed at the point of common coupling (PCC) between the main network and the micro-grid, and it is expected to actively improve the micro-grid’s fault ride-through capability. And for some specific faults, the micro-grid should disconnect from the main network, and the SFCL’s contribution is to make the micro-grid carry out a smooth transition between its grid-connected and islanded modes. Related theory derivation, technical discussion and simulation analysis are performed. From the demonstrated results, applying the SFCL can effectively limit the fault current, maintain the power balance, and enhance the voltage and frequency stability of the micro-grid.

  17. Advanced hybrid transient stability and EMT simulation for VSC-HVDC systems

    NARCIS (Netherlands)

    Van Der Meer, A.A.; Gibescu, M.; Van Der Meijden, M.A.M.M.; Kling, W.L.; Ferreira, J.A.

    2015-01-01

    This paper deals with advanced hybrid transient stability and electromagnetic-transient (EMT) simulation of combined ac/dc power systems containing large amounts of renewable energy sources interfaced through voltage-source converter-high-voltage direct current (VSC-HVDC). The concerning transient

  18. Solenoid-free Plasma Start-up in NSTX using Transient CHI

    International Nuclear Information System (INIS)

    R. Raman, B.A. Nelson, D. Mueller, T.R. Jarboe, M.G. Bell, B. LeBlanc, R. Maqueda, J. Menard, M. Ono, M. Nagata, L. Roquemore, and V. Soukhanovskii

    2008-01-01

    Experiments in NSTX have now unambiguously demonstrated the coupling of toroidal plasmas produced by the technique of CHI to inductive sustainment and ramp-up of the toroidal plasma current. This is an important step because an alternate method for plasma startup is essential for developing a fusion reactor based on the spherical torus concept. Elimination of the central solenoid would also allow greater flexibility in the choice of the aspect ratio in tokamak designs now being considered. The transient CHI method for spherical torus startup was originally developed on the HIT-II experiment at the University of Washington

  19. Recent development of transient electronics

    Directory of Open Access Journals (Sweden)

    Huanyu Cheng

    2016-01-01

    Full Text Available Transient electronics are an emerging class of electronics with the unique characteristic to completely dissolve within a programmed period of time. Since no harmful byproducts are released, these electronics can be used in the human body as a diagnostic tool, for instance, or they can be used as environmentally friendly alternatives to existing electronics which disintegrate when exposed to water. Thus, the most crucial aspect of transient electronics is their ability to disintegrate in a practical manner and a review of the literature on this topic is essential for understanding the current capabilities of transient electronics and areas of future research. In the past, only partial dissolution of transient electronics was possible, however, total dissolution has been achieved with a recent discovery that silicon nanomembrane undergoes hydrolysis. The use of single- and multi-layered structures has also been explored as a way to extend the lifetime of the electronics. Analytical models have been developed to study the dissolution of various functional materials as well as the devices constructed from this set of functional materials and these models prove to be useful in the design of the transient electronics.

  20. A technique to reduce plasma armature formation voltage

    International Nuclear Information System (INIS)

    Jamison, K.A.; Littrell, D.M.

    1991-01-01

    The initiation of a plasma armature by foil vaporization in a railgun is often accompanied by a large, fast, voltage transient appearing on both the breech and muzzle of the gun. For a railgun driven by an inductor/opening switch power supply, this voltage transient becomes a concern during current commutation from the switch to the railgun. To lessen the requirements on the opening switch, techniques must be found to reduce the armature formation voltage. This paper presents the experimental results from railgun firings at AFATL's Electromagnetic Launcher Basic Research Facility (Site A-15, Eglin Air Force Base, Florida) using different shapes of initiation foils. These foils have been designed to vaporize into a plasma armature with reduced transient voltages. A design criteria was developed to ensure that all portions of the foil vaporize at slightly different times

  1. The OECD/NEA/NSC PBMR 400 MW coupled neutronics thermal hydraulics transient benchmark: transient results - 290

    International Nuclear Information System (INIS)

    Strydom, G.; Reitsma, F.; Ngeleka, P.T.; Ivanov, K.N.

    2010-01-01

    The PBMR is a High-Temperature Gas-cooled Reactor (HTGR) concept developed to be built in South Africa. The analysis tools used for core neutronic design and core safety analysis need to be verified and validated, and code-to-code comparisons are an essential part of the V and V plans. As part of this plan the PBMR 400 MWth design and a representative set of transient exercises are defined as an OECD benchmark. The scope of the benchmark is to establish a series of well defined multi-dimensional computational benchmark problems with a common given set of cross sections, to compare methods and tools in coupled neutronics and thermal hydraulics analysis with a specific focus on transient events. This paper describes the current status of the benchmark project and shows the results for the six transient exercises, consisting of three Loss of Cooling Accidents, two Control Rod Withdrawal transients, a power load-follow transient, and a Helium over-cooling Accident. The participants' results are compared using a statistical method and possible areas of future code improvement are identified. (authors)

  2. State, space relay modeling and simulation using the electromagnetic Transients Program and its transient analysis of control systems capability

    International Nuclear Information System (INIS)

    Domijan, A.D. Jr.; Emami, M.V.

    1990-01-01

    This paper reports on a simulation of a MHO distance relay developed to study the effect of its operation under various system conditions. Simulation is accomplished using a state space approach and a modeling technique using ElectroMagnetic Transient Program (Transient Analysis of Control Systems). Furthermore, simulation results are compared with those obtained in another independent study as a control, to validate the results. A data code for the practical utilization of this simulation is given

  3. Runaway transient simulation of a model Kaplan turbine

    Energy Technology Data Exchange (ETDEWEB)

    Liu, S; Liu, D; Wu, Y [State Key Laboratory of Hydroscience and Engineering, Department of Thermal Eng., Tsinghua University, Beijing, 100084 (China); Zhou, D [Water Conservancy and Hydropower Eng., Hohai University, Nanjing. 210098 (China); Nishi, M, E-mail: liushuhong@tsinghua.edu.c [Kyushu Inst. Tech. Senior Academy, Kitakyushu, 804-8550 (Japan)

    2010-08-15

    The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-{epsilon} turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.

  4. Runaway transient simulation of a model Kaplan turbine

    Science.gov (United States)

    Liu, S.; Zhou, D.; Liu, D.; Wu, Y.; Nishi, M.

    2010-08-01

    The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-epsilon turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.

  5. Runaway transient simulation of a model Kaplan turbine

    International Nuclear Information System (INIS)

    Liu, S; Liu, D; Wu, Y; Zhou, D; Nishi, M

    2010-01-01

    The runaway transient is a typical transient process of a hydro power unit, where the rotational speed of a turbine runner rapidly increases up to the runaway speed under a working head as the guide vanes cannot be closed due to some reason at the load rejection. In the present paper, the characteristics of the runaway transient of a model Kaplan turbine having ns = 479(m-kW) is simulated by using a time-dependent CFD technique where equation of rotational motion of runner, continuity equation and unsteady RANS equations with RNG k-ε turbulence model are solved iteratively. In the calculation, unstructured mesh is used to the whole flow passage, which consists of several sub-domains: entrance, casing, stay vanes + guide vanes, guide section, runner and draft tube. And variable speed sliding mesh technique is used to exchange interface flow information between moving part and stationary part, and three-dimensional unstructured dynamic mesh technique is also adopted to ensure mesh quality. Two cases were treated in the simulation of runaway transient characteristics after load rejection: one is the rated operating condition as the initial condition, and the other is the condition at the maximum head. Regarding the runaway speed, the experimental speed is 1.45 times the initial speed and the calculation is 1.47 times the initial for the former case. In the latter case, the experiment and the calculation are 1.67 times and 1.69 times respectively. From these results, it is recognized that satisfactorily prediction will be possible by using the present numerical method. Further, numerical results show that the swirl in the draft-tube flow becomes stronger in the latter part of the transient process so that a vortex rope will occur in the draft tube and its precession will cause the pressure fluctuations which sometimes affect the stability of hydro power system considerably.

  6. Voltage transients in thin-film InSb Hall sensor

    Directory of Open Access Journals (Sweden)

    Alexey Bardin

    Full Text Available The work is reached to study temperature transients in thin-film Hall sensors. We experimentally study InSb thin-film Hall sensor. We find transients of voltage with amplitude about 10 μV on the sensor ports after current switching. We demonstrate by direct measurements that the transients is caused by thermo-e.m.f., and both non-stationarity and heterogeneity of temperature in the film. We find significant asymmetry of temperature field for different direction of the current, which is probably related to Peltier effect. The result can be useful for wide range of scientist who works with switching of high density currents in any thin semiconductor films. 2000 MSC: 41A05, 41A10, 65D05, 65D17, Keywords: Thin-films, Semiconductors, Hall sensor, InSb, thermo-e.m.f.

  7. Motor current and leakage flux signature analysis technique for condition monitoring

    International Nuclear Information System (INIS)

    Pillai, M.V.; Moorthy, R.I.K.; Mahajan, S.C.

    1994-01-01

    Till recently analysis of vibration signals was the only means available to predict the state of health of plant equipment. Motor current and leakage magnetic flux signature analysis is acquiring importance as a technique for detection of incipient damages in the electrical machines and as a supplementary technique for diagnostics of driven equipment such as centrifugal and reciprocating pumps. The state of health of the driven equipment is assessed by analysing time signal, frequency spectrum and trend analysis. For example, the pump vane frequency, piston stroke frequency, gear frequency and bearing frequencies are indicated in the current and flux spectra. By maintaining a periodic record of the amplitudes of various frequency lines in the frequency spectra, it is possible to understand the trend of deterioration of parts and components of the pump. All problems arising out of inappropriate mechanical alignment of vertical pumps are easily identified by a combined analysis of current, flux and vibration signals. It is found that current signature analysis technique is a sufficient method in itself for the analysis of state of health of reciprocating pumps and compressors. (author). 10 refs., 4 figs

  8. Eddy current technique applied to automated tube profilometry

    International Nuclear Information System (INIS)

    Dobbeni, D.; Melsen, C. van

    1982-01-01

    The use of eddy current methods in the first totally automated pre-service inspection of the internal diameter of PWR steam generator tubes is described. The technique was developed at Laborelec, the Belgian Laboratory of the Electricity Supply Industry. Details are given of the data acquisition system and of the automated manipulator. Representative tube profiles are illustrated. (U.K.)

  9. An In-Rush Current Suppression Technique for the Solid-State Transfer Switch System

    Science.gov (United States)

    Cheng, Po-Tai; Chen, Yu-Hsing

    More and more utility companies provide dual power feeders as a premier service of high power quality and reliability. To take advantage of this, the solid-state transfer switch (STS) is adopted to protect the sensitive load against the voltage sag. However, the fast transfer process may cause in-rush current on the load-side transformer due to the resulting DC-offset in its magnetic flux as the load-transfer is completed. The in-rush current can reach 2∼6 p.u. and it may trigger the over-current protections on the power feeder. This paper develops a flux estimation scheme and a thyristor gating scheme based on the impulse commutation bridge STS (ICBSTS) to minimize the DC-offset on the magnetic flux. By sensing the line voltages of both feeders, the flux estimator can predict the peak transient flux linkage at the moment of load-transfer and evaluate a suitable moment for the transfer to minimize the in-rush current. Laboratory test results are presented to validate the performance of the proposed system.

  10. Changes in the action potential and transient outward potassium current in cardiomyocytes during acute cardiac rejection in rats.

    Science.gov (United States)

    Luo, Wenqi; Jia, Yixin; Zheng, Shuai; Li, Yan; Han, Jie; Meng, Xu

    2017-01-01

    Acute cardiac rejection contributes to the changes in the electrophysiological properties of grafted hearts. However, the electrophysiological changes of cardiomyocytes during acute cardiac rejection are still unknown. An understanding of the electrophysiological mechanisms of cardiomyocytes could improve the diagnosis and treatment of acute cardiac rejection. So it is important to characterize the changes in the action potential ( AP ) and the transient outward potassium current ( I to ) in cardiomyocytes during acute cardiac rejection. Heterotopic heart transplantation was performed in allogeneic [Brown Norway (BN)-to-Lewis] and isogeneic (BN-to-BN) rats. Twenty models were established in each group. Ten recipients were sacrificed at the 2nd day and the other ten recipients were sacrificed at the 4 th day after the operation in each group. Histopathological examinations of the grafted hearts were performed in half of the recipients in each group randomly. The other half of the grafted hearts were excised rapidly and enzymatically dissociated to obtain single cardiomyocytes. The AP and I to current were recorded using the whole cell patch-clamp technique. Forty grafted hearts were successfully harvested and used in experiments. Histologic examination showed mild rejection at the 2 nd day and moderate rejection at the 4 th day in the allogeneic group after cardiac transplantation, while no evidence of histologic lesions of rejection were observed in the isogeneic group. Compared with the isogeneic group, the action potential duration ( APD ) of cardiomyocytes in the allogeneic group was significantly prolonged ( APD 90 was 49.28±5.621 mV in the isogeneic group and 88.08±6.445 mV in the allogeneic group at the 2 nd day, P=0.0016; APD 90 was 59.34±5.183 mV in the isogeneic group and 104.0±9.523 mV in the allogeneic group at the 4 th day, P=0.0064). The current density of I to was significantly decreased at the 4 th day after cardiac transplantation. The APD of

  11. Attosecond transient absorption spectroscopy of molecular hydrogen

    International Nuclear Information System (INIS)

    Martín, Fernando; González-Castrillo, Alberto; Palacios, Alicia; Argenti, Luca; Cheng, Yan; Chini, Michael; Wang, Xiaowei; Chang, Zenghu

    2015-01-01

    We extend attosecond transient absorption spectroscopy (ATAS) to the study of hydrogen molecules, demonstrating the potential of the technique to resolve – simultaneously and with state resolution – both the electronic and nuclear dynamics. (paper)

  12. Long gravitational-wave transients and associated detection strategies for a network of terrestrial interferometers

    International Nuclear Information System (INIS)

    Thrane, Eric; Kandhasamy, Shivaraj; Dorsher, Steven; Mandic, Vuk; Prestegard, Tanner; Ott, Christian D.; Anderson, Warren G.; Christensen, Nelson L.; Coughlin, Michael W.; Giampanis, Stefanos; Mytidis, Antonis; Whiting, Bernard; Raffai, Peter

    2011-01-01

    Searches for gravitational waves (GWs) traditionally focus on persistent sources (e.g., pulsars or the stochastic background) or on transients sources (e.g., compact binary inspirals or core-collapse supernovae), which last for time scales of milliseconds to seconds. We explore the possibility of long GW transients with unknown waveforms lasting from many seconds to weeks. We propose a novel analysis technique to bridge the gap between short O(s)''burst'' analyses and persistent stochastic analyses. Our technique utilizes frequency-time maps of GW strain cross power between two spatially separated terrestrial GW detectors. The application of our cross power statistic to searches for GW transients is framed as a pattern recognition problem, and we discuss several pattern-recognition techniques. We demonstrate these techniques by recovering simulated GW signals in simulated detector noise. We also recover environmental noise artifacts, thereby demonstrating a novel technique for the identification of such artifacts in GW interferometers. We compare the efficiency of this framework to other techniques such as matched filtering.

  13. The SEM description of interaction of a transient electromagnetic wave with an object

    Science.gov (United States)

    Pearson, L. W.; Wilton, D. R.

    1980-01-01

    The singularity expansion method (SEM), proposed as a means for determining and representing the transient surface current density induced on a scatterer by a transient electromagnetic wave is described. The resulting mathematical description of the transient surface current on the object is discussed. The data required to represent the electromagnetic scattering properties of a given object are examined. Experimental methods which were developed for the determination of the SEM description are discussed. The feasibility of characterizing the surface current induced on aircraft flying in proximity to a lightning stroke by way of SEM is examined.

  14. Dual Transformer Model based on Standard Circuit Elements for the Study of Low- and Mid-frequency Transients

    Science.gov (United States)

    Jazebi, Saeed

    This thesis is a step forward toward achieving the final objective of creating a fully dual model for transformers including eddy currents and nonlinearities of the iron core using the fundamental electrical components already available in the EMTP-type programs. The model is effective for the study of the performance of transformers during power system transients. This is very important for transformer designers, because the insulation of transformers is determined with the overvoltages caused by lightning or switching operations. There are also internally induced transients that occur when a switch is actuated. For example switching actions for reconfiguration of distribution systems that offers economic advantages, or protective actions to clear faults and large short-circuit currents. Many of the smart grid concepts currently under development by many utilities rely heavily on switching to optimize resources that produce transients in the system. On the other hand, inrush currents produce mechanical forces which deform transformer windings and cause malfunction of the differential protection. Also, transformer performance under ferroresonance and geomagnetic induced currents are necessary to study. In this thesis, a physically consistent dual model applicable to single-phase two-winding transformers is proposed. First, the topology of a dual electrical equivalent circuit is obtained from the direct application of the principle of duality. Then, the model parameters are computed considering the variations of the transformer electromagnetic behavior under various operating conditions. Current modeling techniques use different topological models to represent diverse transient situations. The reversible model proposed in this thesis unifies the terminal and topological equivalent circuits. The model remains invariable for all low-frequency transients including deep saturation conditions driven from any of the two windings. The very high saturation region of the

  15. UNSUPERVISED TRANSIENT LIGHT CURVE ANALYSIS VIA HIERARCHICAL BAYESIAN INFERENCE

    International Nuclear Information System (INIS)

    Sanders, N. E.; Soderberg, A. M.; Betancourt, M.

    2015-01-01

    Historically, light curve studies of supernovae (SNe) and other transient classes have focused on individual objects with copious and high signal-to-noise observations. In the nascent era of wide field transient searches, objects with detailed observations are decreasing as a fraction of the overall known SN population, and this strategy sacrifices the majority of the information contained in the data about the underlying population of transients. A population level modeling approach, simultaneously fitting all available observations of objects in a transient sub-class of interest, fully mines the data to infer the properties of the population and avoids certain systematic biases. We present a novel hierarchical Bayesian statistical model for population level modeling of transient light curves, and discuss its implementation using an efficient Hamiltonian Monte Carlo technique. As a test case, we apply this model to the Type IIP SN sample from the Pan-STARRS1 Medium Deep Survey, consisting of 18,837 photometric observations of 76 SNe, corresponding to a joint posterior distribution with 9176 parameters under our model. Our hierarchical model fits provide improved constraints on light curve parameters relevant to the physical properties of their progenitor stars relative to modeling individual light curves alone. Moreover, we directly evaluate the probability for occurrence rates of unseen light curve characteristics from the model hyperparameters, addressing observational biases in survey methodology. We view this modeling framework as an unsupervised machine learning technique with the ability to maximize scientific returns from data to be collected by future wide field transient searches like LSST

  16. UNSUPERVISED TRANSIENT LIGHT CURVE ANALYSIS VIA HIERARCHICAL BAYESIAN INFERENCE

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, N. E.; Soderberg, A. M. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Betancourt, M., E-mail: nsanders@cfa.harvard.edu [Department of Statistics, University of Warwick, Coventry CV4 7AL (United Kingdom)

    2015-02-10

    Historically, light curve studies of supernovae (SNe) and other transient classes have focused on individual objects with copious and high signal-to-noise observations. In the nascent era of wide field transient searches, objects with detailed observations are decreasing as a fraction of the overall known SN population, and this strategy sacrifices the majority of the information contained in the data about the underlying population of transients. A population level modeling approach, simultaneously fitting all available observations of objects in a transient sub-class of interest, fully mines the data to infer the properties of the population and avoids certain systematic biases. We present a novel hierarchical Bayesian statistical model for population level modeling of transient light curves, and discuss its implementation using an efficient Hamiltonian Monte Carlo technique. As a test case, we apply this model to the Type IIP SN sample from the Pan-STARRS1 Medium Deep Survey, consisting of 18,837 photometric observations of 76 SNe, corresponding to a joint posterior distribution with 9176 parameters under our model. Our hierarchical model fits provide improved constraints on light curve parameters relevant to the physical properties of their progenitor stars relative to modeling individual light curves alone. Moreover, we directly evaluate the probability for occurrence rates of unseen light curve characteristics from the model hyperparameters, addressing observational biases in survey methodology. We view this modeling framework as an unsupervised machine learning technique with the ability to maximize scientific returns from data to be collected by future wide field transient searches like LSST.

  17. Recent advances in transient imaging: A computer graphics and vision perspective

    Directory of Open Access Journals (Sweden)

    Adrian Jarabo

    2017-03-01

    Full Text Available Transient imaging has recently made a huge impact in the computer graphics and computer vision fields. By capturing, reconstructing, or simulating light transport at extreme temporal resolutions, researchers have proposed novel techniques to show movies of light in motion, see around corners, detect objects in highly-scattering media, or infer material properties from a distance, to name a few. The key idea is to leverage the wealth of information in the temporal domain at the pico or nanosecond resolution, information usually lost during the capture-time temporal integration. This paper presents recent advances in this field of transient imaging from a graphics and vision perspective, including capture techniques, analysis, applications and simulation. Keywords: Transient imaging, Ultrafast imaging, Time-of-flight

  18. Search for Transient Gravitational Waves in Coincidence with Short-Duration Radio Transients During 2007-2013

    Science.gov (United States)

    Abbott, B. P.; Hughey, Brennan; Zanolin, Michele; Szczepanczyk, Marek; Gill, Kiranjyot; Abbott, R.; Abbott, T. D.; Abernathy, M. R.; Acernese, F.; Ackley, K.; hide

    2016-01-01

    We present an archival search for transient gravitational-wave bursts in coincidence with 27 single-pulse triggers from Green Bank Telescope pulsar surveys, using the LIGO (Laser Interferometer Gravitational Wave Observatory), Virgo (Variability of Solar Irradiance and Gravity Oscillations) and GEO (German-UK Interferometric Detector) interferometer network. We also discuss a check for gravitational-wave signals in coincidence with Parkes fast radio bursts using similar methods. Data analyzed in these searches were collected between 2007 and 2013. Possible sources of emission of both short-duration radio signals and transient gravitational-wave emission include star quakes on neutron stars, binary coalescence of neutron stars, and cosmic string cusps. While no evidence for gravitational-wave emission in coincidence with these radio transients was found, the current analysis serves as a prototype for similar future searches using more sensitive second-generation interferometers.

  19. Transient electromagnetic detecting technique for water hazard to the roof of fully mechanized sub-level caving face

    Energy Technology Data Exchange (ETDEWEB)

    Yu Jing-cun; Liu Zhi-xin; Tang Jin-yun; Wang Yang-zhou [China University of Mining & Technology, Xuzhou (China). School of Resources and Geoscience Science

    2007-07-01

    In coal mining, with the popularization of fully mechanized equipment, the roof control becomes more and more important. The development of water body in roofs may seriously affect the efficiency of the fully mechanized mining, quite possible to cause an accident in working face. Therefore, to make clear the position of a water body located in roofs so as to provide a basis for water drainage borehole layout is an urgent problem to be solved by geophysical exploration. Based on the transient electromagnetic theory and the technique used on ground surface and on the actual situation in underground coal mines, a square superimposed loop device (2 m in side length) which is non-contact and multi-turns was developed to detect the water bodies in coal seam roofs. Based on the 'smoke ring effect' theory and the physical simulation criterion, the mathematical model for calculating the apparent resistivity of full space transient electromagnetism is deduced. In addition, the water detection technology for the roof of fully mechanized sub-level caving face was researched and applied in several coal mines, which has been verified by boreholes and mining practice, indicating that this method is very effective in detecting the water source in the roof of fully mechanized sub-level caving face. 11 refs., 5 figs.

  20. Transients and burn dynamics in advanced tokamak fusion reactors

    International Nuclear Information System (INIS)

    Mantsinen, M.J.; Salomaa, R.R.E.

    1994-01-01

    Transient behavior of D 3 He-tokamak reactors is investigated numerically using a zero-dimensional code with prescribed profiles. Pure D 3 He start-up is compared to DT-assisted and DT-ignited start-ups. We have considered two categories of transients which could extinguish steady fusion burn: fuelling interruptions and sudden confinement changes similar to the L → H transients occurring in present-day tokamaks. Shutdown with various current and density ramp-down scenarios are studied, too. (author)

  1. Eddy current techniques for super duplex stainless steel characterization

    Energy Technology Data Exchange (ETDEWEB)

    Camerini, C., E-mail: cgcamerini@metalmat.ufrj.br [Laboratory of Non-Destructive Testing, Corrosion and Welding, Department of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro (Brazil); Sacramento, R.; Areiza, M.C.; Rocha, A. [Laboratory of Non-Destructive Testing, Corrosion and Welding, Department of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro (Brazil); Santos, R. [PETROBRAS R& D Center, Rio de Janeiro (Brazil); Rebello, J.M.; Pereira, G. [Laboratory of Non-Destructive Testing, Corrosion and Welding, Department of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro (Brazil)

    2015-08-15

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content. - Highlights: • Sigma phase precipitation, even for low amounts, dramatically affects SDSS properties. • SDSS samples were thermally treated and carefully characterized by X-Ray Diffraction. • NDT techniques detected low amounts of sigma phase in SDSS microstructure.

  2. Eddy current techniques for super duplex stainless steel characterization

    International Nuclear Information System (INIS)

    Camerini, C.; Sacramento, R.; Areiza, M.C.; Rocha, A.; Santos, R.; Rebello, J.M.; Pereira, G.

    2015-01-01

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content. - Highlights: • Sigma phase precipitation, even for low amounts, dramatically affects SDSS properties. • SDSS samples were thermally treated and carefully characterized by X-Ray Diffraction. • NDT techniques detected low amounts of sigma phase in SDSS microstructure

  3. The walking-induced transient hack concept is valid & relies on a transient early-exercise hypoxemia.

    Directory of Open Access Journals (Sweden)

    Antoine Bruneau

    Full Text Available Decreased arterial oxygen pressure obtained at peak exercise is strong evidence of walking-induced hypoxemia, assuming that the lower pressure occurs just before exercise is stopped. Using empirical predefined models and transcutaneous oximetry, we have shown that some patients reporting exercise intolerance show a minimal value at the onset of walking and a post-exercise overshoot. These changes are referred to as transcutaneous "walking-induced transient hacks".In 245 patients, walking-induced transcutaneous oxygen pressure changes in the chest were analyzed using observer-independent clustering techniques. Clustering classes were compared to the profile types previously proposed with the cross-correlation technique. The classifications of patients according to both approaches were compared using kappa statistics. In 10 patients showing a hack on transcutaneous oximetry, we analyzed the results of direct iterative arterial sampling recorded during a new walking treadmill test.Clustering analysis resulted in 4 classes that closely fit the 4 most frequently proposed empirical models (cross-correlation coefficients: 0.93 to 0.97. The kappa between the two classifications was 0.865. In 10 patients showing transcutaneous hacks, the minimal direct arterial oxygen pressure value occurred at exercise onset, and these patients exhibited a recovery overshoot reaching a maximum at two minutes of recovery, confirming the walking-induced transient hypoxemia.In patients reporting exercise intolerance, transcutaneous oximetry could help to detect walking-induced transient hypoxemia, while peak-exercise arterial oximetry might be normal.

  4. Current and planned numerical development for improving computing performance for long duration and/or low pressure transients

    International Nuclear Information System (INIS)

    Faydide, B.

    1997-01-01

    This paper presents the current and planned numerical development for improving computing performance in case of Cathare applications needing real time, like simulator applications. Cathare is a thermalhydraulic code developed by CEA (DRN), IPSN, EDF and FRAMATOME for PWR safety analysis. First, the general characteristics of the code are presented, dealing with physical models, numerical topics, and validation strategy. Then, the current and planned applications of Cathare in the field of simulators are discussed. Some of these applications were made in the past, using a simplified and fast-running version of Cathare (Cathare-Simu); the status of the numerical improvements obtained with Cathare-Simu is presented. The planned developments concern mainly the Simulator Cathare Release (SCAR) project which deals with the use of the most recent version of Cathare inside simulators. In this frame, the numerical developments are related with the speed up of the calculation process, using parallel processing and improvement of code reliability on a large set of NPP transients

  5. Current and planned numerical development for improving computing performance for long duration and/or low pressure transients

    Energy Technology Data Exchange (ETDEWEB)

    Faydide, B. [Commissariat a l`Energie Atomique, Grenoble (France)

    1997-07-01

    This paper presents the current and planned numerical development for improving computing performance in case of Cathare applications needing real time, like simulator applications. Cathare is a thermalhydraulic code developed by CEA (DRN), IPSN, EDF and FRAMATOME for PWR safety analysis. First, the general characteristics of the code are presented, dealing with physical models, numerical topics, and validation strategy. Then, the current and planned applications of Cathare in the field of simulators are discussed. Some of these applications were made in the past, using a simplified and fast-running version of Cathare (Cathare-Simu); the status of the numerical improvements obtained with Cathare-Simu is presented. The planned developments concern mainly the Simulator Cathare Release (SCAR) project which deals with the use of the most recent version of Cathare inside simulators. In this frame, the numerical developments are related with the speed up of the calculation process, using parallel processing and improvement of code reliability on a large set of NPP transients.

  6. Measurement of radiation induced transients in hybrid microcircuits by magnetic thin film sensor/recorders

    International Nuclear Information System (INIS)

    Hsieh, E.J.; Vindelov, K.E.; Brown, T.G.; Miller, D.E.

    1976-01-01

    Magnetic thin film transient current sensor/recorders were modified to make two types of nuclear test measurements, transient currents in hybrid microcircuits and internal electromagnetic pulse (IEMP) fields. The measurements were made possible by the invention of split-domain sensor/recorders which can measure bilateral currents and can be reset and readout on location. The sensor/recorders were used in two underground nuclear tests and numerous calibration tests in radiation-simulation machines. The data showed that the nuclear environment had negligible effect on the sensor/recorder's operation and the recorded informations on the sensor/recorders were the signals intended to be monitored. Also, the experimental data agreed with the theoretical analysis in controlled experiments. The data were examined first by on location readout with a magnetic tape viewer and later by Kerr magneto-optic readout in the laboratory. To translate the data into current readings, we reconstructed facsimile data (on each of the sensor/recorders) in the laboratory by current pulses with the same pulse width as the radiation event. An additional check on the accuracy of the data was made by using both the sensor/recorder and the conventional pickup-oscilloscope-camera technique to monitor the same current lead in a simulated radiation environment. Over five runs were made, and the agreement among the two measurement methods was within 25%. The data collectively implied that the measurements were reliable and dependable

  7. Accelerating transient simulation of linear reduced order models.

    Energy Technology Data Exchange (ETDEWEB)

    Thornquist, Heidi K.; Mei, Ting; Keiter, Eric Richard; Bond, Brad

    2011-10-01

    Model order reduction (MOR) techniques have been used to facilitate the analysis of dynamical systems for many years. Although existing model reduction techniques are capable of providing huge speedups in the frequency domain analysis (i.e. AC response) of linear systems, such speedups are often not obtained when performing transient analysis on the systems, particularly when coupled with other circuit components. Reduced system size, which is the ostensible goal of MOR methods, is often insufficient to improve transient simulation speed on realistic circuit problems. It can be shown that making the correct reduced order model (ROM) implementation choices is crucial to the practical application of MOR methods. In this report we investigate methods for accelerating the simulation of circuits containing ROM blocks using the circuit simulator Xyce.

  8. Spectroscopy and reactions of vibrationally excited transient molecules

    Energy Technology Data Exchange (ETDEWEB)

    Dai, H.L. [Univ. of Pennsylvania, Philadelphia (United States)

    1993-12-01

    Spectroscopy, energy transfer and reactions of vibrationally excited transient molecules are studied through a combination of laser-based excitation techniques and efficient detection of emission from the energized molecules with frequency and time resolution. Specifically, a Time-resolved Fourier Transform Emission Spectroscopy technique has been developed for detecting dispersed laser-induced fluorescence in the IR, visible and UV regions. The structure and spectroscopy of the excited vibrational levels in the electronic ground state, as well as energy relaxation and reactions induced by specific vibronic excitations of a transient molecule can be characterized from time-resolved dispersed fluorescence in the visible and UV region. IR emissions from highly vibrational excited levels, on the other hand, reveal the pathways and rates of collision induced vibrational energy transfer.

  9. Effects of modulation techniques on the input current interharmonics of Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Soltani, Hamid; Davari, Pooya; Zare, Firuz

    2018-01-01

    operation of the grid. This paper presents the effect of the symmetrical regularly sampled Space Vector Modulation (SVM) and Discontinuous Pulse Width Modulation-30olag (DPWM2) techniques, as the most popular modulation methods in the ASD applications, on the drive’s input current interharmonic magnitudes....... Further investigations are also devoted to the cases, where the Random Modulation (RM) technique is applied on the selected modulation strategies. The comparative results show that how different modulation techniques can influence the ASD’s input current interharmonics and consequently may...

  10. Suppressing voltage transients in high voltage power supplies

    International Nuclear Information System (INIS)

    Lickel, K.F.; Stonebank, R.

    1979-01-01

    A high voltage power supply for an X-ray tubes includes voltage adjusting means, a high voltage transformer, switch means connected to make and interrupt the primary current of the transformer, and over-voltage suppression means to suppress the voltage transient produced when the current is switched on. In order to reduce the power losses in the suppression means, an impedance is connected in the transformer primary circuit on operation of the switch means and is subsequently short-circuited by a switch controlled by a timer after a period which is automatically adjusted to the duration of the transient overvoltage. (U.K.)

  11. Problems with numerical techniques: Application to mid-loop operation transients

    Energy Technology Data Exchange (ETDEWEB)

    Bryce, W.M.; Lillington, J.N.

    1997-07-01

    There has been an increasing need to consider accidents at shutdown which have been shown in some PSAs to provide a significant contribution to overall risk. In the UK experience has been gained at three levels: (1) Assessment of codes against experiments; (2) Plant studies specifically for Sizewell B; and (3) Detailed review of modelling to support the plant studies for Sizewell B. The work has largely been carried out using various versions of RELAP5 and SCDAP/RELAP5. The paper details some of the problems that have needed to be addressed. It is believed by the authors that these kinds of problems are probably generic to most of the present generation system thermal-hydraulic codes for the conditions present in mid-loop transients. Thus as far as possible these problems and solutions are proposed in generic terms. The areas addressed include: condensables at low pressure, poor time step calculation detection, water packing, inadequate physical modelling, numerical heat transfer and mass errors. In general single code modifications have been proposed to solve the problems. These have been very much concerned with means of improving existing models rather than by formulating a completely new approach. They have been produced after a particular problem has arisen. Thus, and this has been borne out in practice, the danger is that when new transients are attempted, new problems arise which then also require patching.

  12. Measuring voltage transients with an ultrafast scanning tunneling microscope

    DEFF Research Database (Denmark)

    Keil, Ulrich Dieter Felix; Jensen, Jacob Riis; Hvam, Jørn Märcher

    1997-01-01

    circuit, where the tunneling tip is directly connected to the current amplifier of the scanning tunneling microscope, this dependence is eliminated. Ail results can be explained with coupling through the geometrical capacitance of the tip-electrode junction. By illuminating the current......We use an ultrafast scanning tunneling microscope to resolve propagating voltage transients in space and time. We demonstrate that the previously observed dependence of the transient signal amplitude on the tunneling resistance was only caused by the electrical sampling circuit. With a modified...

  13. Transient Peripapillary Retinoschisis in Glaucomatous Eyes

    Directory of Open Access Journals (Sweden)

    Josine van der Schoot

    2017-01-01

    Full Text Available Purpose. To investigate transient focal microcystic retinoschisis in glaucomatous eyes in images obtained with several imaging techniques used in daily glaucoma care. Methods. Images of 117 glaucoma patients and 91 healthy subjects participating in a large prospective follow-up study into glaucoma imaging were reviewed. Participants were measured with spectral domain optical coherence tomography (SD-OCT, scanning laser polarimetry (SLP, scanning laser tomography (SLT, and standard automated perimetry (SAP. The presence of a focal retinoschisis in SD-OCT was observed and correlated to SLP, SLT, and SAP measurements, both cross-sectionally and longitudinally. Results. Seven out of 117 glaucoma patients showed a transient, localised, peripapillary, heterogeneous microcystic schisis of the retinal nerve fiber layer (RNFL and sometimes other retinal layers as well in SD-OCT. None of the healthy eyes showed this phenomenon nor did any of the other imaging techniques display it as detailed and consistently as did the SD-OCT. SAP showed a temporarily decreased focal retinal sensitivity during the retinoschisis and we found no signs of glaucomatous progression related to the retinoschisis. Conclusions. Transient microcystic retinoschisis appears to be associated with glaucomatous wedge defects in the RNFL. It was best observed with SD-OCT and it was absent in healthy eyes. We found no evidence that the retinoschisis predicted glaucomatous progression.

  14. Charged particle transport in gaseous nitrogen at intermediate E/N using the voltage transient method

    International Nuclear Information System (INIS)

    Purdie, P.H.; Fletcher, J.

    1992-01-01

    A pulsed swarm of charged particles crossing an inter-electrode gap under the influence of an applied electric field E will produce a pulsed current in the external circuit which, when integrated over time, will result in a transient voltage pulse, the shape and magnitude of which is characteristic of the number of type of charged particles. This voltage transient technique has been used to investigate a gas discharge in nitrogen gas at values of E/N (the ratio of applied electric field to gas number density), such that ionization is non-negligible. The voltage transients have been subjected to a theoretical analysis, which has previously been reported, which includes not only cathode and anode image terms but also both electron and ion diffusion terms. Electron transport parameters are reported for E/N ≤ 350 Td (1 Td = 10 -17 V cm 2 ). Data are also obtained for the drift velocities and diffusion coefficients of the ions operative within the nitrogen discharge. An estimate is obtained for the collisional decay rate of N 2 + . 21 refs., 7 figs

  15. Biomagnetic localization from transient quasi-static events

    Energy Technology Data Exchange (ETDEWEB)

    Mosher, J.C.; Leahy, R.M.; Lewis, P.S. [Los Alamos National Lab., NM (United States)]|[University of Southern California, Los Angeles, CA (United States). Signal and Image Processing Inst.

    1993-02-01

    Sensory stimuli, such as auditory, visual, or somatosensory, evoke neural responses in very localized regions of the brain. A SQUID biomagnetometer can measure the very weak fields that are generated outside of the head by this response. A simple source and head model of current dipoles inside a conducting sphere is typically used to interpret these magnetic field measurements or magnetoencephalogram (MEG). Locating dipole sources using data recorded from an array of biomagnetic sensors is distinguished from conventional array source localization techniques by the quasi-static transient nature of the data. Here, the basic MEG model is reviewed, then a localization example is given to motivate the need for partitioning the data to improve estimator performance. Tune-eigenspectrum analysis is introduced as a means of partitioning and interpreting spatio-temporal biomagnetic data. Examples using both simulated and somatosensory data are presented.

  16. Biomagnetic localization from transient quasi-static events

    Energy Technology Data Exchange (ETDEWEB)

    Mosher, J.C.; Leahy, R.M.; Lewis, P.S. (Los Alamos National Lab., NM (United States) University of Southern California, Los Angeles, CA (United States). Signal and Image Processing Inst.)

    1993-01-01

    Sensory stimuli, such as auditory, visual, or somatosensory, evoke neural responses in very localized regions of the brain. A SQUID biomagnetometer can measure the very weak fields that are generated outside of the head by this response. A simple source and head model of current dipoles inside a conducting sphere is typically used to interpret these magnetic field measurements or magnetoencephalogram (MEG). Locating dipole sources using data recorded from an array of biomagnetic sensors is distinguished from conventional array source localization techniques by the quasi-static transient nature of the data. Here, the basic MEG model is reviewed, then a localization example is given to motivate the need for partitioning the data to improve estimator performance. Tune-eigenspectrum analysis is introduced as a means of partitioning and interpreting spatio-temporal biomagnetic data. Examples using both simulated and somatosensory data are presented.

  17. Characterization of an electrothermal plasma source for fusion transient simulations

    Science.gov (United States)

    Gebhart, T. E.; Baylor, L. R.; Rapp, J.; Winfrey, A. L.

    2018-01-01

    The realization of fusion energy requires materials that can withstand high heat and particle fluxes at the plasma material interface. In this work, an electrothermal (ET) plasma source has been designed as a transient heat flux source for a linear plasma material interaction device. An ET plasma source operates in the ablative arc regime driven by a DC capacitive discharge. The current channel width is defined by the 4 mm bore of a boron nitride liner. At large plasma currents, the arc impacts the liner wall, leading to high particle and heat fluxes to the liner material, which subsequently ablates and ionizes. This results in a high density plasma with a large unidirectional bulk flow out of the source exit. The pulse length for the ET source has been optimized using a pulse forming network to have durations of 1 and 2 ms. The peak currents and maximum source energies seen in this system are 1.9 kA and 1.2 kJ for the 2 ms pulse and 3.2 kA and 2.1 kJ for the 1 ms pulse, respectively. This work is a proof of the principal project to show that an ET source produces electron densities and heat fluxes comparable to those anticipated in transient events in large future magnetic confinement fusion devices. Heat flux, plasma temperature, and plasma density were determined for each shot using infrared imaging and optical spectroscopy techniques. This paper will discuss the assumptions, methods, and results of the experiments.

  18. Schlieren techniques and interferometric methods using TEA-CO2 lasers for the investigation of transient phenomena by means of thermal liquid crystal image converters

    International Nuclear Information System (INIS)

    Hugenschmidt, M.; Vollrath, K.

    In order to investigate plasmas with electron densities in the 10 15 to 10 18 cm -3 range, schlieren techniques and interferometric methods are used with a TEA-CO 2 laser. The thermooptical conversion is achieved by means of cholesteric liquid crystal layers. The possible uses of this technique are examined in view of recording dynamic transient phenomena, attention being paid to response time, resolving power, and quantitative information obtained. Examples are given for records taken from the formation and expansion of electric spark discharges. The experimental results are in good agreement with the computed numerical data [fr

  19. Study of pulse stretching in high current power supplies using multipulse techniques

    International Nuclear Information System (INIS)

    Trendler, R.C.

    1977-01-01

    Considerable interest exists at Fermilab to increase the pulse width of the Neutrino Focusing Horn to permit an increase in beam spill length from twenty (20) microseconds to one (1) millisecond. Two techniques to do this were examined: (1) a high current transformer, and (2) increased bank capacitance using the multi-power supply technique. The transformer is the most straightforward conceptually; it is, however, a complicated device requiring sizable changes to the existing horn power supply. This alternative is briefly reviewed. The second scheme involves pulsing a 20 kv 200 ka power supply to establish the required load current and then maintaining this current by the sequential pulsing of a number of low voltage high current power supplies. This alternative is discussed in detail with the results of tests performed on the Fermilab Focusing Horn System

  20. Eddy current techniques for super duplex stainless steel characterization

    Science.gov (United States)

    Camerini, C.; Sacramento, R.; Areiza, M. C.; Rocha, A.; Santos, R.; Rebello, J. M.; Pereira, G.

    2015-08-01

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content.

  1. Static and transient beam loading of a synchrotron

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Weng, W.T.

    1992-01-01

    In a synchrotron, when the beam induced current is comparable to the driver current, the RF cavity is subjected to beam loading perturbation and corrective steps have to be implemented to regain beam stability. In this paper, the static and transient beam loading will be studied. We first discuss the static beam loading, which includes the cavity detuning condition, the stability condition, and the generator power dissipation. The beam current induced beam phase deviation is used as criterion to study the transient beam loading. The upgraded and the old AGS RF system parameters are used as an example to demonstrate how to choose cavity and generator parameters to satisfy the stability requirements under the beam loading. The dynamic models for the beam loading with beam control, and the beam loading with fast power amplifier feedback are presented and analyzed. It is shown that the beam phase and radial feedbacks alone are insufficient for the transient beam loading compensation, but the fast power amplifier feedback can provide effective correction on the beam loading. The limitation of the fast feedback and the beam loading with tuning and AVC loops are also discussed

  2. Modeling of HVDC System to Improve Estimation of Transient DC Current and Voltages for AC Line-to-Ground Fault—An Actual Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Dohoon Kwon

    2017-10-01

    Full Text Available A new modeling method for high voltage direct current (HVDC systems and associated controllers is presented for the power system simulator for engineering (PSS/E simulation environment. The aim is to improve the estimation of the transient DC voltage and current in the event of an AC line-to-ground fault. The proposed method consists primary of three interconnected modules for (a equation conversion; (b control-mode selection; and (c DC-line modeling. Simulation case studies were carried out using PSS/E and a power systems computer aided design/electromagnetic transients including DC (PSCAD/EMTDC model of the Jeju– Haenam HVDC system in Korea. The simulation results are compared with actual operational data and the PSCAD/EMTDC simulation results for an HVDC system during single-phase and three-phase line-to-ground faults, respectively. These comparisons show that the proposed PSS/E modeling method results in the improved estimation of the dynamic variation in the DC voltage and current in the event of an AC network fault, with significant gains in computational efficiency, making it suitable for real-time analysis of HVDC systems.

  3. PWR plant transient analyses using TRAC-PF1

    International Nuclear Information System (INIS)

    Ireland, J.R.; Boyack, B.E.

    1984-01-01

    This paper describes some of the pressurized water reactor (PWR) transient analyses performed at Los Alamos for the US Nuclear Regulatory Commission using the Transient Reactor Analysis Code (TRAC-PF1). Many of the transient analyses performed directly address current PWR safety issues. Included in this paper are examples of two safety issues addressed by TRAC-PF1. These examples are pressurized thermal shock (PTS) and feed-and-bleed cooling for Oconee-1. The calculations performed were plant specific in that details of both the primary and secondary sides were modeled in addition to models of the plant integrated control systems. The results of these analyses show that for these two transients, the reactor cores remained covered and cooled at all times posing no real threat to the reactor system nor to the public

  4. Application of sensitivity analysis to a simplified coupled neutronic thermal-hydraulics transient in a fast reactor using Adjoint techniques

    International Nuclear Information System (INIS)

    Gilli, L.; Lathouwers, D.; Kloosterman, J.L.; Van der Hagen, T.H.J.J.

    2011-01-01

    In this paper a method to perform sensitivity analysis for a simplified multi-physics problem is presented. The method is based on the Adjoint Sensitivity Analysis Procedure which is used to apply first order perturbation theory to linear and nonlinear problems using adjoint techniques. The multi-physics problem considered includes a neutronic, a thermo-kinetics, and a thermal-hydraulics part and it is used to model the time dependent behavior of a sodium cooled fast reactor. The adjoint procedure is applied to calculate the sensitivity coefficients with respect to the kinetic parameters of the problem for two reference transients using two different model responses, the results obtained are then compared with the values given by a direct sampling of the forward nonlinear problem. Our first results show that, thanks to modern numerical techniques, the procedure is relatively easy to implement and provides good estimation for most perturbations, making the method appealing for more detailed problems. (author)

  5. Status report for anticipated transients without scram for Combustion Engineering reactors

    International Nuclear Information System (INIS)

    1975-01-01

    The NRC staff review of Combustion ATWS analyses included the anticipated transients expected to occur, the initial conditions and system parameters assumed in the analyses, the reliability of systems, the analytical techniques, the results of transient analysis of ATWS events and the design of the Reactor Protection System. Using the requirements of WASH-1270 as a guideline, the staff reviewed each relevant aspect of the Combustion model and analysis. The discussion of anticipated transients is presented, and the initial conditions, system parameters, and operating systems assumed in the analyses of these transients are discussed. The analytical techniques and computer programs are reviewed. An independent calculation conducted by the staff using the RELAP-3B code to determine the pressure within the reactor coolant pressure boundary during a complete loss of main feedwater ATWS event is described. A set of standard problems is defined for all pressurized water reactor vendors and the Regulatory staff to insure acceptability of computer codes used in all systems transient analyses. The model for calculating water discharge through primary valves is described. The comparison of the Combustion analyses to the requirements of WASH-1270 is presented. Certain outstanding issues are identified which require that Combustion or the applicant provide additional information or modify existing designs

  6. Development of Eddy Current Technique for Reactor In-Core Flux Thimble Wear

    International Nuclear Information System (INIS)

    Park, S. S.; Jang, Y. Y.; Yim, C. Y.; Park, K. H.

    1990-01-01

    Since in-core flux thimble tube wear the due to flow-induced vibration could degrade the integrity of nuclear reactor, the effective detection and interpretation of the wear is important. In order to establish an inspection technique for thimble tubes, an eddy current experiment was performed to determine the optimum test frequency, defect sensitivity and evaluation accuracy. Eddy current probes were designed and fabricated with a theory. Specimens with artificial defects were fabricated using electro discharge machining method. The results from inspection technique developed and on-site inspection showed good applicability

  7. Nondestructive evaluation of a cermet coating using ultrasonic and eddy current techniques

    International Nuclear Information System (INIS)

    Roge, B.; Fahr, A.; Giguere, J.S.R.; McRae, K.I.

    2002-01-01

    This paper describes a series of experiments conducted to characterize cermet coatings using conventional ultrasonic and eddy current techniques as well as an ultrasonic leaky surface wave method. The results demonstrate the ability of these techniques to detect the presence of artificial defects on the surface or beneath the surface of the coating. In addition, ultrasonic tests in particular ultrasonic leaky surface waves demonstrate the ability to detect the presence of manufacturing flaws. Ultrasonic time-of-flight and eddy current quadrature measurements also show sensitivity to variations in coating thickness

  8. A review on transient monitoring systems

    International Nuclear Information System (INIS)

    Baylac, G.

    1986-01-01

    A good design must be followed by the continuous verification during service of design basis hypotheses. Transient monitoring techniques described hereafter were developed to fulfill this very logical requirement. They are shown to be useful to improve the reliability, operability, inspection and lifetime of components of the Reactor Coolant Pressure Boundary. 16 refs.

  9. Low-frequency transient electric and magnetic fields coupling to child body

    International Nuclear Information System (INIS)

    Ozen, S.

    2008-01-01

    Much of the research related to residential electric and magnetic field exposure focuses on cancer risk for children. But until now only little knowledge about coupling of external transient electric and magnetic fields with the child's body at low frequency transients existed. In this study, current densities, in the frequency range from 50 Hz up to 100 kHz, induced by external electric and magnetic fields to child and adult human body, were investigated, as in residential areas, electric and magnetic fields become denser in this frequency band. For the calculations of induced fields and current density, the ellipsoidal body models are used. Current density induced by the external magnetic field (1 μT) and external electric field (1 V/m) is estimated. The results of this study show that the transient electric and magnetic fields would induce higher current density in the child body than power frequency fields with similar field strength. (authors)

  10. Investigation of electrically active defects in InGaAs quantum wire intermediate-band solar cells using deep-level transient spectroscopy (DLTS) technique

    OpenAIRE

    Al Saqri, Noor alhuda; Felix, Jorlandio F.; Aziz, Mohsin; Kunets, Vasyl P.; Jameel, Dler Adil; Taylor, David; Henini, M.; Abd El-sadek, Mahmmoud S.; Furrow, Colin; Ware, Morgan E.; Benamara, Mourad; Mortazavi, Mansour; Salamo, Gregory

    2016-01-01

    InGaAs quantum wire (QWr) intermediate-band solar cell based nanostructures grown by molecular beam epitaxy are studied. The electrical and interface properties of these solar cell devices, as determined by current–voltage (I–V) and capacitance–voltage (C-V) techniques, were found to change with temperature over a wide range of 20–340 K. The electron and hole traps present in these devices have been investigated using deep-level transient spectroscopy (DLTS). The DLTS results showed that the ...

  11. Technique of Critical Current Density Measurement of Bulk Superconductor with Linear Extrapolation Method

    International Nuclear Information System (INIS)

    Adi, Wisnu Ari; Sukirman, Engkir; Winatapura, Didin S.

    2000-01-01

    Technique of critical current density measurement (Jc) of HTc bulk ceramic superconductor has been performed by using linear extrapolation with four-point probes method. The measurement of critical current density HTc bulk ceramic superconductor usually causes damage in contact resistance. In order to decrease this damage factor, we introduce extrapolation method. The extrapolating data show that the critical current density Jc for YBCO (123) and BSCCO (2212) at 77 K are 10,85(6) Amp.cm - 2 and 14,46(6) Amp.cm - 2, respectively. This technique is easier, simpler, and the use of the current flow is low, so it will not damage the contact resistance of the sample. We expect that the method can give a better solution for bulk superconductor application. Key words. : superconductor, critical temperature, and critical current density

  12. Application of transient magnetic field to the measurement of nuclear magnetic moments

    International Nuclear Information System (INIS)

    Ribas, R.V.

    1987-01-01

    A review on: the mechanism for producing transient magnetic field; techniques for measuring nuclear gyromagnetic factor; and some examples of recent measurements using this technique is presented. (M.C.K.) [pt

  13. Transient well flow in vertically heterogeneous aquifers

    Science.gov (United States)

    Hemker, C. J.

    1999-11-01

    A solution for the general problem of computing well flow in vertically heterogeneous aquifers is found by an integration of both analytical and numerical techniques. The radial component of flow is treated analytically; the drawdown is a continuous function of the distance to the well. The finite-difference technique is used for the vertical flow component only. The aquifer is discretized in the vertical dimension and the heterogeneous aquifer is considered to be a layered (stratified) formation with a finite number of homogeneous sublayers, where each sublayer may have different properties. The transient part of the differential equation is solved with Stehfest's algorithm, a numerical inversion technique of the Laplace transform. The well is of constant discharge and penetrates one or more of the sublayers. The effect of wellbore storage on early drawdown data is taken into account. In this way drawdowns are found for a finite number of sublayers as a continuous function of radial distance to the well and of time since the pumping started. The model is verified by comparing results with published analytical and numerical solutions for well flow in homogeneous and heterogeneous, confined and unconfined aquifers. Instantaneous and delayed drainage of water from above the water table are considered, combined with the effects of partially penetrating and finite-diameter wells. The model is applied to demonstrate that the transient effects of wellbore storage in unconfined aquifers are less pronounced than previous numerical experiments suggest. Other applications of the presented solution technique are given for partially penetrating wells in heterogeneous formations, including a demonstration of the effect of decreasing specific storage values with depth in an otherwise homogeneous aquifer. The presented solution can be a powerful tool for the analysis of drawdown from pumping tests, because hydraulic properties of layered heterogeneous aquifer systems with

  14. Characterization of electrical appliances in transient state

    Science.gov (United States)

    Wójcik, Augustyn; Winiecki, Wiesław

    2017-08-01

    The article contains the study about electrical appliance characterization on the basis of power grid signals. To represent devices, parameters of current and voltage signals recorded during transient states are used. In this paper only transients occurring as a result of switching on devices are considered. The way of data acquisition performed in specialized measurement setup developed for electricity load monitoring is described. The paper presents the method of transients detection and the method of appliance parameters calculation. Using the set of acquired measurement data and appropriate software the set of parameters for several household appliances operating in different operating conditions was processed. Usefulness of appliances characterization in Non-Intrusive Appliance Load Monitoring System (NIALMS) with the use of proposed method is discussed focusing on obtained results.

  15. Current techniques for the investigation of vulnerable atherosclerotic plaques

    International Nuclear Information System (INIS)

    Riou, L.; Broisat, A.; Fagret, D.; Ghezzi, C.

    2005-01-01

    Atherosclerosis is the single most important contributor to cardiovascular diseases, the leading cause of death in industrialized countries. Atherosclerosis complications such as vulnerable coronary plaque rupture or erosion result in acute coronary events, i.e. myocardial infarction and sudden death. Vulnerable plaques initially develop eccentrically without impeding on the vessel lumen and are therefore not detectable using angiography. New techniques for the investigation of vulnerable plaques are needed to identify and treat vulnerable patients. Invasive techniques require the use of intracoronary probes and are thereby not applicable to large populations of patients. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are the most promising invasive modalities. They provide morphological data that could potentially be associated with a more functional approach such as thermography, elasto-graphy, or spectroscopy, Non-invasive techniques are better suited for studying larger populations of patients. Computed tomography is currently used for calcium scoring, but the biological meaning and the prognostic value of this index remain to be fully determined. Non-invasive coronary magnetic resonance imaging (MRI) faces numerous technical challenges, and it essentially provides morphological data. Molecular nuclear imaging offers a great sensitivity and the ability to provide metabolic data about atherosclerotic lesions. New potential tracers of vulnerable plaques are currently being evaluated. Nuclear Medicine should therefore play a major role in the future as a non invasive imaging modality for the assessment of vulnerable atherosclerotic plaques. (author)

  16. A current-mode DC—DC buck converter with adaptive zero compensation

    International Nuclear Information System (INIS)

    Yang Ling; Dai Guoding; Xu Chongwei; Liu Yuezhi

    2013-01-01

    To achieve fast transient response for a DC—DC buck converter, an adaptive zero compensation circuit is presented. The compensation resistance is dynamically adjusted according to the different output load conditions, and achieves an adequate system phase margin under the different conditions. An improved capacitor multiplier circuit is adopted to realize the minimized compensation capacitance size. In addition, analysis of the small-signal model shows the correctness of the mechanism of the proposed adaptive zero compensation technique. A current-mode DC—DC buck converter with the proposed structure has been implemented in a 0.35 μm CMOS process, and the die size is only 800 × 1040 μm 2 . The experimental results show that the transient undershoot/overshoot voltage and the recovery times do not exceed 40 mV and 30 μs for a load current variation from 100 mA to 1 A. (semiconductor integrated circuits)

  17. An overview of optimization of structures subjected to transient loads

    International Nuclear Information System (INIS)

    Kang, Byung Soo; Park, Gyung Jin

    2005-01-01

    Various aspects of structural optimization techniques under transient loads are extensively reviewed. The main themes of the paper are treatment of time dependent constraints, calculation of design sensitivity, and approximation. Each subject is reviewed with the corresponding papers that have been published since 1970s. The treatment of time dependent constraints in both the direct method and the transformation method is discussed. Two ways of calculating design sensitivity of a structure under transient loads are discussed-direct differentiation method and adjoint variable method. The approximation concept mainly focuses on response surface method in crashworthiness and local approximation with the intermediate variable. Especially, as an approximated optimization technique, equivalent static load method which takes advantage of the well-established static response optimization technique is introduced. And as an application area of dynamic response optimization technique, the structural optimization in flexible multibody dynamic system is reviewed in the viewpoint of the above three themes

  18. Multibeam Gpu Transient Pipeline for the Medicina BEST-2 Array

    Science.gov (United States)

    Magro, A.; Hickish, J.; Adami, K. Z.

    2013-09-01

    Radio transient discovery using next generation radio telescopes will pose several digital signal processing and data transfer challenges, requiring specialized high-performance backends. Several accelerator technologies are being considered as prototyping platforms, including Graphics Processing Units (GPUs). In this paper we present a real-time pipeline prototype capable of processing multiple beams concurrently, performing Radio Frequency Interference (RFI) rejection through thresholding, correcting for the delay in signal arrival times across the frequency band using brute-force dedispersion, event detection and clustering, and finally candidate filtering, with the capability of persisting data buffers containing interesting signals to disk. This setup was deployed at the BEST-2 SKA pathfinder in Medicina, Italy, where several benchmarks and test observations of astrophysical transients were conducted. These tests show that on the deployed hardware eight 20 MHz beams can be processed simultaneously for 640 Dispersion Measure (DM) values. Furthermore, the clustering and candidate filtering algorithms employed prove to be good candidates for online event detection techniques. The number of beams which can be processed increases proportionally to the number of servers deployed and number of GPUs, making it a viable architecture for current and future radio telescopes.

  19. Current status on techniques for determining paleo-temperature using geothermometer

    International Nuclear Information System (INIS)

    Kanazawa, Sunao; Oikawa, Teruki; Umeda, Koji; Tomiyama, Shingo

    2005-01-01

    Development of the research technologies for geotectonic events has been carried out to evaluate the long-term stability of geological environment. In terms of the effects of geothermal activity, it is necessary to estimate the geothermal regime and thermal history on any given site. This paper describes the current status on techniques for determining paleo-temperature using geothermometer, and presents a concept of the systematic research techniques. The application of geothermometer, especially thermochronology, has been effective in the studies on the cooling history of geological body and the paleo-geothermal structure at depth. (author)

  20. An electron beam induced current study of gallium nitride and diamond materials

    International Nuclear Information System (INIS)

    Cropper, A.D.; Moore, D.J.; Scott, C.S.; Green, R.

    1995-01-01

    The continual need for microelectronic devices that operate under severe electronic and environmental conditions (high temperature, high frequency, high power, and radiation tolerance) has sustained research in wide bandgap semiconductor materials. The properties suggest these wide-bandgap semiconductor materials have tremendous potential for military and commercial applications. High frequency bipolar transistors and field effect transistors, diodes, and short wavelength optical devices have been proposed using these materials. Although research efforts involving the study of transport properties in Gallium Nitride (GaN) and Diamond have made significant advances, much work is still needed to improve the material quality so that the electrophysical behavior of device structures can be further understood and exploited. Electron beam induced current (EBIC) measurements can provide a method of understanding the transport properties in Gallium Nitride (GaN) and Diamond. This technique basically consists of measuring the current or voltage transient response to the drift and diffusion of carriers created by a short-duration pulse of radiation. This method differs from other experimental techniques because it is based on a fast transient electron beam probe created from a high speed, laser pulsed photoemission system

  1. Fast Turn-off Mine Transient Electromagnetic Transmitter System

    Directory of Open Access Journals (Sweden)

    ZHENG Xiao-Liang

    2014-05-01

    Full Text Available For solving problems such as short turn-off time, high linear degree of falling edge, measurement of turn-off time and influence of primary signals for transient electromagnetic transmitter, and restrictions because of the environmental conditions of underground coal mine, this thesis aims at designing a new transient electromagnetic transmitter system suitable for coal mine. Supported by damping absorption circuit, such system applies small volume, sectional transmitting coil, with features of short turn-off time, high linear degree of current falling edge. It uses the transmitter monitoring circuit, which accurately measures turn-off time and simultaneously records the current value changes after turn-off, thus to eliminate the influence of primary field as well as to restore earlier secondary field signals for reference and finally to improve the ability to detect the shallow structure. It turns out that the new system has a shorter turn-off time, a higher linear degree of current falling and more accurate data record of turn-off current.

  2. Heavy-ion induced current through an oxide layer

    International Nuclear Information System (INIS)

    Takahashi, Yoshihiro; Ohki, Takahiro; Nagasawa, Takaharu; Nakajima, Yasuhito; Kawanabe, Ryu; Ohnishi, Kazunori; Hirao, Toshio; Onoda, Shinobu; Mishima, Kenta; Kawano, Katsuyasu; Itoh, Hisayoshi

    2007-01-01

    In this paper, the heavy-ion induced current in MOS structure is investigated. We have measured the transient gate current in a MOS capacitor and a MOSFET induced by single heavy-ions, and found that a transient current can be observed when the semiconductor surface is under depletion condition. In the case of MOSFET, a transient gate current with both positive and negative peaks is observed if the ion hits the gate area, and that the total integrated charge is almost zero within 100-200 ns after irradiation. From these results, we conclude that the radiation-induced gate current is dominated by a displacement current. We also discuss the generation mechanism of the radiation-induced current through the oxide layer by device simulation

  3. Optimization of Agrobacterium-mediated transient expression of heterologous genes in spinach

    DEFF Research Database (Denmark)

    Cao, Dang Viet; Pamplona, Reniel S.; Kim, Jiwon

    2017-01-01

    The Agrobacterium-mediated transient assay is a relatively rapid technique and a promising approach for assessing the expression of a gene of interest. Despite the successful application of this transient expression system in several plant species, it is not well understood in spinach. In this st...

  4. In beam test of a transient magnetic field based g factor setup

    International Nuclear Information System (INIS)

    Saxena, Mansi; Mandal, S.; Siwal, Davinder; Kumar, Chandan; Goyal, Savi; Garg, Ritika; Khushboo; Rohilla, Aman; Kumar, Naveen; Kumar, S.; Chamoli, S.; Mandal, A.; Kumar, Rajesh; Barua, P.; Kumar, R.; Gujjar, R.; Bala, Indu; Singh, R.P.; Muralithar, S.; Rehman, Anisur; Roy, Minakshi

    2012-01-01

    Magnetic moments or g factors provide substantial information on the microscopic structure of the nuclei. Since the g factor is very different in sign and magnitude for neutrons and protons, therefore they can serve as a good indicator as to which nucleon contributes most to the wave function of that state. There are different techniques available for measuring g factors depending on the lifetime of the state involved. Using transient field technique we can measure the g factor of nuclei having a lifetime of the order of several hundreds of femto seconds. To measure the g factor of such low lifetime states we have designed and fabricated a setup based on the Transient Field Technique Measurement

  5. Transient chaos in a globally coupled system of nearly conservative Hamiltonian Duffing oscillators

    International Nuclear Information System (INIS)

    Sabarathinam, S.; Thamilmaran, K.

    2015-01-01

    Highlights: •We have examined transient chaos in globally coupled oscillators. •We analyze transient chaos using new techniques. •We give experimental confirmation of transient chaos. -- Abstract: In this work, transient chaos in a ring and globally coupled system of nearly conservative Hamiltonian Duffing oscillators is reported. The networks are formed by coupling of three, four and six Duffing oscillators. The nearly conservative Hamiltonian nature of the coupled system is proved by stability analysis. The transient phenomenon is confirmed through various numerical investigations such as recurrence analysis, 0–1 test and Finite Time Lyapunov Exponents. Further, the effect of damping and the average transient lifetime of three, four and six coupled schemes for randomly generated initial conditions have been analyzed. The experimental confirmation of transient chaos in an illustrative system of three ringly coupled Duffing oscillators is also presented

  6. Revisiting renovascular imaging for renal sympathetic denervation: current techniques and applications

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei; Tan, Cher Heng [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Ho, Hee Hwa; Tan, Julian Ko Beng; Ong, Paul Jau Leong [Tan Tock Seng Hospital, Department of Cardiology, Singapore (Singapore)

    2014-08-28

    Renal sympathetic denervation (RDN) is an emerging technique in the treatment of resistant hypertension, most commonly performed using an endovascular approach. Clinical and anatomical criteria for RDN are well established and imaging plays an integral role in selecting patients with suitable anatomy, procedural planning and device selection. Nevertheless, the current body of literature surrounding imaging related to RDN remains limited. The purpose of this article is to illustrate the expectations and limitations of various imaging techniques, including Doppler ultrasound, CT angiography, MR angiography and newer techniques such as non-contrast MR angiography, in the context of RDN. (orig.)

  7. Revisiting renovascular imaging for renal sympathetic denervation: current techniques and applications

    International Nuclear Information System (INIS)

    Pua, Uei; Tan, Cher Heng; Ho, Hee Hwa; Tan, Julian Ko Beng; Ong, Paul Jau Leong

    2015-01-01

    Renal sympathetic denervation (RDN) is an emerging technique in the treatment of resistant hypertension, most commonly performed using an endovascular approach. Clinical and anatomical criteria for RDN are well established and imaging plays an integral role in selecting patients with suitable anatomy, procedural planning and device selection. Nevertheless, the current body of literature surrounding imaging related to RDN remains limited. The purpose of this article is to illustrate the expectations and limitations of various imaging techniques, including Doppler ultrasound, CT angiography, MR angiography and newer techniques such as non-contrast MR angiography, in the context of RDN. (orig.)

  8. Current limiting capability of diffused resistors

    International Nuclear Information System (INIS)

    Shedd, W.; Cappelli, J.

    1979-01-01

    An experimental evaluation of the current limiting capability of dielectrically isolated diffused resistors at transient ionizing dose rates up to 6*10 12 rads(Si)/sec is presented. Existing theoretical predictions of the transient response of diffused resistors are summarized and compared to the experimentally measured values. The test resistors used allow the effects of sheet resistance and geometry on the transient response to be determined. The experimental results show that typical dielectrically isolated diffused resistors maintain adequate current limiting capability for use in radiation hardened integrated circuits

  9. Automated transient identification in the Dark Energy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, D. A. [Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). et al.

    2015-08-20

    We describe an algorithm for identifying point-source transients and moving objects on reference-subtracted optical images containing artifacts of processing and instrumentation. The algorithm makes use of the supervised machine learning technique known as Random Forest. We present results from its use in the Dark Energy Survey Supernova program (DES-SN), where it was trained using a sample of 898,963 signal and background events generated by the transient detection pipeline. After reprocessing the data collected during the first DES-SN observing season (2013 September through 2014 February) using the algorithm, the number of transient candidates eligible for human scanning decreased by a factor of 13.4, while only 1.0 percent of the artificial Type Ia supernovae (SNe) injected into search images to monitor survey efficiency were lost, most of which were very faint events. Here we characterize the algorithm's performance in detail, and we discuss how it can inform pipeline design decisions for future time-domain imaging surveys, such as the Large Synoptic Survey Telescope and the Zwicky Transient Facility.

  10. Transient Stability Enhancement in Power System Using Static VAR Compensator (SVC

    Directory of Open Access Journals (Sweden)

    Youssef MOULOUDI

    2012-12-01

    Full Text Available In this paper, an indirect adaptive fuzzy excitation and static VAR (unit of reactive power, volt-ampere reactive compensator (SVC controller is proposed to enhance transient stability for the power system, which based on input-output linearization technique. A three-bus system, which contains a generator and static VAR compensator (SVC, is considered in this paper, the SVC is located at the midpoint of the transmission lines. Simulation results show that the proposed controller compared with a controller based on tradition linearization technique can enhance the transient stability of the power system under a large sudden fault, which may occur nearly at the generator bus terminal.

  11. Laser spectroscopy and dynamics of transient species

    Energy Technology Data Exchange (ETDEWEB)

    Clouthier, D.J. [Univ. of Kentucky, Lexington (United States)

    1993-12-01

    The goal of this program is to study the vibrational and electronic spectra and excited state dynamics of a number of transient sulfur and oxygen species. A variety of supersonic jet techniques, as well as high resolution FT-IR and intracavity dye laser spectroscopy, have been applied to these studies.

  12. Electromagnetic Transients in Power Cables

    DEFF Research Database (Denmark)

    Silva, Filipe Faria Da; Bak, Claus Leth

    . The chapter ends by proposing a systematic method that can be used when doing the insulation co-ordination study for a line, as well as the modelling requirements, both modelling depth and modelling detail of the equipment, for the study of the different types of transients followed by a step-by-step generic...... typically used for the screens of cables (both-ends bonding and cross-boding) and also presents methods that can be used to estimate the maximum current of a cable for different types of soils, i.e. thermal calculations. The end of the chapter introduces the shunt reactor, which is an important element...... detail of the equipment, for the study of the different types of transients followed by a step-by-step generic example....

  13. Inverse transient thermoelastic deformations in thin circular plates

    Indian Academy of Sciences (India)

    Bessel's functions with the help of the integral transform technique. Thermoelastic deformations are discussed with the help of temperature and are illustrated numer- ically. Keywords. Inverse transient; thermoelastic deformation. 1. Introduction. The inverse thermoelastic problem consists of determination of the temperature, ...

  14. Transient Stability Improvement of IEEE 9 Bus System Using Power World Simulator

    Directory of Open Access Journals (Sweden)

    Kaur Ramandeep

    2016-01-01

    Full Text Available The improvement of transient stability of power system was one of the most challenging research areas in power engineer.The main aim of this paper was transient stability analysis and improvement of IEEE 9 bus system. These studies were computed using POWER WORLD SIMULATOR. The IEEE 9 bus system was modelled in power world simulator and load flow studies were performed to determine pre-fault conditions in the system using Newton-Raphson method. The transient stability analysis was carried out using Runga method during three-phase balanced fault. For the improvement transient stability, the general methods adopted were fast acting exciters, FACT devices and addition of parallel transmission line. These techniques play an important role in improving the transient stability, increasing transmission capacity and damping low frequency oscillations.

  15. Segregated copper ratio experiment on transient stability (SeCRETS). Final Report

    International Nuclear Information System (INIS)

    Bruzzone, P.

    2001-01-01

    Two Nb 3 Sn, steel jacketed, cable-in-conduit conductors have been manufactured with identical non-Cu cross sections and the stabilizer either included in the Nb 3 Sn composite or partly segregated as copper wires. The two conductors are series connected and wound as a bifilar , single layer solenoid, assembled in the high field bore (11 T) of the SULTAN test facility. The operating current is up to 12 kA (400 A/mm 2 ). A transverse pulsed field is applied with ΔB up to 2.7 T, field rate up to 180 T/s and field integral up to 530 T 2 /s. In the dc test, a good agreement is found between the I c and the T cs results, both correctly scaling according to the parameters derived from the strand tests. The n-value from the V-I curve is in the range of 15. The current sharing at the high field section is correlated with a local current re-distribution, observed by arrays of miniature Hall sensors, detecting the self-field around the conductor. The ac losses results in the range of 2 to 9 Hz by gas flow calorimetry indicate coupling currents constant, nτ, in the range of 1.5 ms at high field, increasing by a factor of 2 with 12 kA transport current. Loss extrapolation to 0 frequency suggests that the loss curve may be not linear outside the test range, with higher nτ at lower field rate. The calorimetric loss estimation at the fast field transient (f=15 Hz) indicates nτ ≅ 2 ms. The ITER plasma disruption transients have been reproduced by the pulsed coils. Due to the very low ac losses, no quench could be generated in either conductor even reducing the temperature margin below 0.2-0.3 K. Very large field transients, with integral above 100 T 2 /s, are required to quench the conductors. In that range, the conductor without segregated copper has superior performance. Due to the large interstrand resistance (very low ac losses), the segregated copper has marginal contribution to the stability. No evidence of current redistribution is observed during the field transients

  16. Transients in reactors for power systems compensation

    Science.gov (United States)

    Abdul Hamid, Haziah

    This thesis describes new models and investigations into switching transient phenomena related to the shunt reactors and the Mechanically Switched Capacitor with Damping Network (MSCDN) operations used for reactive power control in the transmission system. Shunt reactors and MSCDN are similar in that they have reactors. A shunt reactor is connected parallel to the compensated lines to absorb the leading current, whereas the MSCDN is a version of a capacitor bank designed as a C-type filter for use in the harmonic-rich environment. In this work, models have been developed and transient overvoltages due to shunt reactor deenergisation were estimated analytically using MathCad, a mathematical program. Computer simulations used the ATP/EMTP program to reproduce both single-phase and three-phase shunt reactor switching at 275 kV operational substations. The effect of the reactor switching on the circuit breaker grading capacitor was also examined by considering various switching conditions.. The main original achievement of this thesis is the clarification of failure mechanisms occurring in the air-core filter reactor due to MSCDN switching operations. The simulation of the MSCDN energisation was conducted using the ATP/EMTP program in the presence of surge arresters. The outcome of this simulation shows that extremely fast transients were established across the air-core filter reactor. This identified transient event has led to the development of a detailed air-core reactor model, which accounts for the inter-turn RLC parameters as well as the stray capacitances-to-ground. These parameters are incorporated into the transient simulation circuit, from which the current and voltage distribution across the winding were derived using electric field and equivalent circuit modelling. Analysis of the results has revealed that there are substantial dielectric stresses imposed on the winding insulation that can be attributed to a combination of three factors. (i) First, the

  17. Proposed Suitable Methods to Detect Transient Regime Switching to Improve Power Quality with Wavelet Transform

    Directory of Open Access Journals (Sweden)

    Javad Safaee Kuchaksaraee

    2016-10-01

    Full Text Available The increasing consumption of electrical energy and the use of non-linear loads that create transient regime states in distribution networks is increasing day by day. This is the only reason due to which the analysis of power quality for energy sustainability in power networks has become more important. Transients are often created by energy injection through switching or lightning and make changes in voltage and nominal current. Sudden increase or decrease in voltage or current makes characteristics of the transient regime. This paper shed some lights on the capacitor bank switching, which is one of the main causes for oscillatory transient regime states in the distribution network, using wavelet transform. The identification of the switching current of capacitor bank and the internal fault current of the transformer to prevent the unnecessary outage of the differential relay, it propose a new smart method. The accurate performance of this method is shown by simulation in EMTP and MATLAB (matrix laboratory software.

  18. Transient selection in multicellular immune networks

    Science.gov (United States)

    Ivanchenko, M. V.

    2011-03-01

    We analyze the dynamics of a multi-clonotype naive T-cell population competing for survival signals from antigen-presenting cells. We find that this competition provides with an efficacious selection of clonotypes, making the less able and more repetitive get extinct. We uncover the scaling principles for large systems the extinction rate obeys and calibrate the model parameters to their experimental counterparts. For the first time, we estimate the physiological values of the T-cell receptor-antigen presentation profile recognition probability and T-cell clonotypes niche overlap. We demonstrate that, while the ultimate state is a stable fixed point, sequential transients dominate the dynamics over large timescales that may span over years, if not decades, in real time. We argue that what is currently viewed as "homeostasis" is a complex sequential transient process, while being quasi-stationary in the total number of T-cells only. The discovered type of sequential transient dynamics in large random networks is a novel alternative to the stable heteroclinic channel mechanism.

  19. Belt conveyor dynamics in transient operation for speed control

    OpenAIRE

    He, D.; Pang, Y.; Lodewijks, G.

    2016-01-01

    Belt conveyors play an important role in continuous dry bulk material transport, especially at the mining industry. Speed control is expected to reduce the energy consumption of belt conveyors. Transient operation is the operation of increasing or decreasing conveyor speed for speed control. According to literature review, current research rarely takes the conveyor dynamics in transient operation into account. However, in belt conveyor speed control, the conveyor dynamic behaviors are signifi...

  20. Construction of a High Temporal-spectral Resolution Spectrometer for Detection of Fast Transients from Observations of the Sun at 1.4 GHz.

    Science.gov (United States)

    Casillas-Perez, G. A.; Jeyakumar, S.; Perez-Enriquez, R.

    2014-12-01

    Transients explosive events with time durations from nanoseconds to several hours, are observed in the Sun at high energy bands such as gamma ray and xray. In the radio band, several types of radio bursts are commonly detected from the ground. A few observations of the Sun in the past have also detected a new class of fast transients which are known to have short-live electromagnetic emissions with durations less than 100 ms. The mechanisms that produce such fast transiets remain unclear. Observations of such fast transients over a wide bandwidth is necessary to uderstand the underlying physical process that produce such fast transients. Due to their very large flux densities, fast radio transients can be observed at high time resolution using small antennas in combination with digital signal processing techniques. In this work we report the progress of an spectrometer that is currently in construction at the Observatorio de la Luz of the Universidad de Guanajuato. The instrument which will have the purpose of detecting solar fast radio transients, involves the use of digital devices such as FPGA and ADC cards, in addition with a receiver with high temporal-spectral resolution centered at 1.4 GHz and a pair of 2.3 m satellite dish.

  1. MgB2-based superconductors for fault current limiters

    Science.gov (United States)

    Sokolovsky, V.; Prikhna, T.; Meerovich, V.; Eisterer, M.; Goldacker, W.; Kozyrev, A.; Weber, H. W.; Shapovalov, A.; Sverdun, V.; Moshchil, V.

    2017-02-01

    A promising solution of the fault current problem in power systems is the application of fast-operating nonlinear superconducting fault current limiters (SFCLs) with the capability of rapidly increasing their impedance, and thus limiting high fault currents. We report the results of experiments with models of inductive (transformer type) SFCLs based on the ring-shaped bulk MgB2 prepared under high quasihydrostatic pressure (2 GPa) and by hot pressing technique (30 MPa). It was shown that the SFCLs meet the main requirements to fault current limiters: they possess low impedance in the nominal regime of the protected circuit and can fast increase their impedance limiting both the transient and the steady-state fault currents. The study of quenching currents of MgB2 rings (SFCL activation current) and AC losses in the rings shows that the quenching current density and critical current density determined from AC losses can be 10-20 times less than the critical current determined from the magnetization experiments.

  2. Scanning tone burst eddy-current thermography (S-TBET) for NDT of carbon fiber reinforced plastic (CFRP) components

    International Nuclear Information System (INIS)

    Libin, M. N.; Maxfield, B. W.; Balasubramanian, Krishnan

    2014-01-01

    Tone Burst Eddy Current technique uses eddy current to apply transient heating inside a component and uses a conventional IR camera for visualization of the response to the transient heating. This technique has been earliest demonstrated for metallic components made of AL, Steel, Stainless Steel, etc., and for detection of cracks, corrosion and adhesive dis-bonds. Although, not nearly as conducting as metals, the Carbon Fibre Reinforced Plastic (CFRP) material absorbs measurable electromagnetic radiation in the frequency range above 10 kHz. When the surface temperature is observed on the surface that is being heated (defined as the surface just beneath and slightly to one side of the heating coil), the surface temperature increases with increasing frequency because the internal heating increases with frequency. A 2-D anisotropic transient Eddy current heating and thermal conduction model has been developed that provides a reasonable description of the processes described above. The inherent anisotropy of CFRP laminates is included in this model by calculating the heating due to three superimposed, tightly coupled isotropic layers having a specified ply-layup. The experimental apparatus consists of an induction heating coil and an IR camera with low NETD and high frame rates. The coil is moved over the sample using a stepper motor controlled manipulator. The IR data recording is synchronized with the motion control to provide a movie of the surface temperature over time. Several components were evaluated for detection of impact damage, location of stiffeners, etc. on CFRP components

  3. Scanning tone burst eddy-current thermography (S-TBET) for NDT of carbon fiber reinforced plastic (CFRP) components

    Energy Technology Data Exchange (ETDEWEB)

    Libin, M. N.; Maxfield, B. W.; Balasubramanian, Krishnan [Centre for Nondestructive Evaluation, Indian Institute of Technology Madras, Chennai 600036 (India)

    2014-02-18

    Tone Burst Eddy Current technique uses eddy current to apply transient heating inside a component and uses a conventional IR camera for visualization of the response to the transient heating. This technique has been earliest demonstrated for metallic components made of AL, Steel, Stainless Steel, etc., and for detection of cracks, corrosion and adhesive dis-bonds. Although, not nearly as conducting as metals, the Carbon Fibre Reinforced Plastic (CFRP) material absorbs measurable electromagnetic radiation in the frequency range above 10 kHz. When the surface temperature is observed on the surface that is being heated (defined as the surface just beneath and slightly to one side of the heating coil), the surface temperature increases with increasing frequency because the internal heating increases with frequency. A 2-D anisotropic transient Eddy current heating and thermal conduction model has been developed that provides a reasonable description of the processes described above. The inherent anisotropy of CFRP laminates is included in this model by calculating the heating due to three superimposed, tightly coupled isotropic layers having a specified ply-layup. The experimental apparatus consists of an induction heating coil and an IR camera with low NETD and high frame rates. The coil is moved over the sample using a stepper motor controlled manipulator. The IR data recording is synchronized with the motion control to provide a movie of the surface temperature over time. Several components were evaluated for detection of impact damage, location of stiffeners, etc. on CFRP components.

  4. Transient difference solutions of the inhomogeneous wave equation - Simulation of the Green's function

    Science.gov (United States)

    Baumeister, K. J.

    1983-01-01

    A time-dependent finite difference formulation to the inhomogeneous wave equation is derived for plane wave propagation with harmonic noise sources. The difference equation and boundary conditions are developed along with the techniques to simulate the Dirac delta function associated with a concentrated noise source. Example calculations are presented for the Green's function and distributed noise sources. For the example considered, the desired Fourier transformed acoustic pressures are determined from the transient pressures by use of a ramping function and an integration technique, both of which eliminates the nonharmonic pressure associated with the initial transient.

  5. Transient difference solutions of the inhomogeneous wave equation: Simulation of the Green's function

    Science.gov (United States)

    Baumeiste, K. J.

    1983-01-01

    A time-dependent finite difference formulation to the inhomogeneous wave equation is derived for plane wave propagation with harmonic noise sources. The difference equation and boundary conditions are developed along with the techniques to simulate the Dirac delta function associated with a concentrated noise source. Example calculations are presented for the Green's function and distributed noise sources. For the example considered, the desired Fourier transformed acoustic pressures are determined from the transient pressures by use of a ramping function and an integration technique, both of which eliminates the nonharmonic pressure associated with the initial transient.

  6. Nuclear radioactive techniques applied to materials research

    CERN Document Server

    Correia, João Guilherme; Wahl, Ulrich

    2011-01-01

    In this paper we review materials characterization techniques using radioactive isotopes at the ISOLDE/CERN facility. At ISOLDE intense beams of chemically clean radioactive isotopes are provided by selective ion-sources and high-resolution isotope separators, which are coupled on-line with particle accelerators. There, new experiments are performed by an increasing number of materials researchers, which use nuclear spectroscopic techniques such as Mössbauer, Perturbed Angular Correlations (PAC), beta-NMR and Emission Channeling with short-lived isotopes not available elsewhere. Additionally, diffusion studies and traditionally non-radioactive techniques as Deep Level Transient Spectroscopy, Hall effect and Photoluminescence measurements are performed on radioactive doped samples, providing in this way the element signature upon correlation of the time dependence of the signal with the isotope transmutation half-life. Current developments, applications and perspectives of using radioactive ion beams and tech...

  7. Transient compressible flows in porous media

    International Nuclear Information System (INIS)

    Morrison, F.A. Jr.

    1975-09-01

    Transient compressible flow in porous media was investigated analytically. The major portion of the investigation was directed toward improving and understanding of dispersion in these flows and developing rapid accurate numerical techniques for predicting the extent of dispersion. The results are of interest in the containment of underground nuclear experiments. The transient one-dimensional transport of a trace component in a gas flow is analyzed. A conservation equation accounting for the effects of convective transport, dispersive transport, and decay, is developed. This relation, as well as a relation governing the fluid flow, is used to predict trace component concentration as a function of position and time. A detailed analysis of transport associated with the isothermal flow of an ideal gas is done. Because the governing equations are nonlinear, numerical calculations are performed. The ideal gas flow is calculated using a highly stable implicit iterative procedure with an Eulerian mesh. In order to avoid problems of anomolous dispersion associated with finite difference calculation, trace component convection and dispersion are calculated using a Lagrangian mesh. Details of the Eulerian-Lagrangian numerical technique are presented. Computer codes have been developed and implemented on the Lawrence Livermore Laboratory computer system

  8. Current control loop of 3-phase grid-connected inverter

    International Nuclear Information System (INIS)

    Jabbar, A F; Mansor, M

    2013-01-01

    This paper presents a comparative study of current control loop in 3-phase inverter which is used to control the active and reactive output power. Generally, current control loop, power control loop and phase lock-loop are the conventional parameters that can be found in an inverter system controlled by the conventional linear control type, for instance proportional (P), integral (I) and derivative (D). If the grid remains stable throughout the day, PID control can be use. However variation of magnitude, frequency, voltage dips, transient, and other related power quality issues occur in a 3-phase grid often affects the control loop. This paper aims to provide an overall review on the available current control techniques used in grid connected system.

  9. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    Energy Technology Data Exchange (ETDEWEB)

    Lijuan Zou

    2003-08-05

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm{sup 2}, the optimal radiance R could reach 0.38 mW/cm{sup 2}, and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be {approx} 10{sup -5} cm{sup 2}/Vs and {approx} 10{sup -4} cm{sup 2}/Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces.

  10. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    International Nuclear Information System (INIS)

    Lijuan Zou

    2003-01-01

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm 2 , the optimal radiance R could reach 0.38 mW/cm 2 , and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be ∼ 10 -5 cm 2 /Vs and ∼ 10 -4 cm 2 /Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces

  11. RIA testing capability of the transient reactor test facility

    International Nuclear Information System (INIS)

    Crawford, D.C.; Swanson, R.W.

    1999-01-01

    The advent of high-burnup fuel implementation in LWRs has generated international interest in high-burnup LWR fuel performance. Recent testing under simulated RIA conditions has demonstrated that certain fuel designs fail at peak fuel enthalpy values that are below existing regulatory criteria. Because many of these tests were performed with non-prototypically aggressive test conditions (i.e., with power pulse widths less than 10 msec FWHM and with non-protoypic coolant configurations), the results (although very informative) do not indisputably identify failure thresholds and fuel behavior. The capability of the TREAT facility to perform simulated RIA tests with prototypic test conditions is currently being evaluated by ANL personnel. TREAT was designed to accommodate test loops and vehicles installed for in-pile transient testing. During 40 years of TREAT operation and fuel testing and evaluation, experimenters have been able to demonstrate and determine the transient behavior of several types of fuel under a variety of test conditions. This experience led to an evolution of test methodology and techniques which can be employed to assess RIA behavior of LWR fuel. A pressurized water loop that will accommodate RIA testing of LWR and CANDU-type fuel has completed conceptual design. Preliminary calculations of transient characteristics and energy deposition into test rods during hypothetical TREAT RIA tests indicate that with the installation of a pressurized water loop, the facility is quite capable of performing prototypic RIA testing. Typical test scenarios indicate that a simulated RIA with a 72 msec FWHM pulse width and energy deposition of 1200 kJ/kg (290 cal/gm) is possible. Further control system enhancements would expand the capability to pulse widths as narrow as 40 msec. (author)

  12. Identification of nuclear power plant transients using the Particle Swarm Optimization algorithm

    International Nuclear Information System (INIS)

    Canedo Medeiros, Jose Antonio Carlos; Schirru, Roberto

    2008-01-01

    In order to help nuclear power plant operator reduce his cognitive load and increase his available time to maintain the plant operating in a safe condition, transient identification systems have been devised to help operators identify possible plant transients and take fast and right corrective actions in due time. In the design of classification systems for identification of nuclear power plants transients, several artificial intelligence techniques, involving expert systems, neuro-fuzzy and genetic algorithms have been used. In this work we explore the ability of the Particle Swarm Optimization algorithm (PSO) as a tool for optimizing a distance-based discrimination transient classification method, giving also an innovative solution for searching the best set of prototypes for identification of transients. The Particle Swarm Optimization algorithm was successfully applied to the optimization of a nuclear power plant transient identification problem. Comparing the PSO to similar methods found in literature it has shown better results

  13. Identification of nuclear power plant transients using the Particle Swarm Optimization algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Canedo Medeiros, Jose Antonio Carlos [Universidade Federal do Rio de Janeiro, PEN/COPPE, UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: canedo@lmp.ufrj.br; Schirru, Roberto [Universidade Federal do Rio de Janeiro, PEN/COPPE, UFRJ, Ilha do Fundao s/n, CEP 21945-970 Rio de Janeiro (Brazil)], E-mail: schirru@lmp.ufrj.br

    2008-04-15

    In order to help nuclear power plant operator reduce his cognitive load and increase his available time to maintain the plant operating in a safe condition, transient identification systems have been devised to help operators identify possible plant transients and take fast and right corrective actions in due time. In the design of classification systems for identification of nuclear power plants transients, several artificial intelligence techniques, involving expert systems, neuro-fuzzy and genetic algorithms have been used. In this work we explore the ability of the Particle Swarm Optimization algorithm (PSO) as a tool for optimizing a distance-based discrimination transient classification method, giving also an innovative solution for searching the best set of prototypes for identification of transients. The Particle Swarm Optimization algorithm was successfully applied to the optimization of a nuclear power plant transient identification problem. Comparing the PSO to similar methods found in literature it has shown better results.

  14. Simulation of transient effects in the heavy ion fusion injectors

    International Nuclear Information System (INIS)

    Chen, Y.J.; Hewett, D.

    1993-01-01

    The authors have used the 2-D PIC code, GYMNOS, to study the transient behaviors in the Heavy Ion Fusion (HIF) injectors. GYMNOS simulations accurately provide the steady state Child-Langmuir current and the beam transient behavior within a planar diode. The simulations of the LBL HIF ESAC injector experiments agree well with the experimental data and EGUN steady state results. Simulations of the nominal HIF injectors have revealed the need to design the accelerating electrodes carefully to control the ion beam current, particularly the ion loss at the end of the bunch as the extraction voltage is reduced

  15. Simulation of transient effects in the heavy ion fusion injectors

    Science.gov (United States)

    Chen, Yu-Jiuan; Hewett, D. W.

    1993-05-01

    We have used the 2-D PIC code, GYMNOS, to study the transient behaviors in the Heavy Ion Fusion (HIF) injectors. GYMNOS simulations accurately provide the steady state Child-Langmuir current and the beam transient behavior within a planar diode. The simulations of the LBL HIF ESAC injector experiments agree well with the experimental data and EGUN steady state results. Simulations of the nominal HIF injectors have revealed the need to design the accelerating electrodes carefully to control the ion beam current, particularly the ion loss at the end of the bunch as the extraction voltage is reduced.

  16. Development of an eddy current inspection technique for sleeved engine disk bolt holes

    International Nuclear Information System (INIS)

    Palanisamy, R.; Lakin, K.M.

    1983-01-01

    Recent research programs have concentrated mainly on developing techniques to characterize surface breaking cracks and very little has been done towards characterizing subsurface flaws in conducting materials. Presented in this paper are the results of some initial theoretical work aimed at the development of a reliable eddy current technique to detect and characterize defects in engine disk bolt holes under a 0.05'' stainless steel sleeve. The change in impedance of an absolute eddy current coil with and without ferrite core, and the distribution of eddy currents around a second layer crack with and without a thin insulating film between the two conducting layers have been predicted numerically. The overall system development goals and methods to accomplish them are outlined briefly

  17. Defect detection in conducting materials using eddy current testing techniques

    Directory of Open Access Journals (Sweden)

    Brauer Hartmut

    2014-01-01

    Full Text Available Lorentz force eddy current testing (LET is a novel nondestructive testing technique which can be applied preferably to the identification of internal defects in nonmagnetic moving conductors. The LET is compared (similar testing conditions with the classical eddy current testing (ECT. Numerical FEM simulations have been performed to analyze the measurements as well as the identification of internal defects in nonmagnetic conductors. The results are compared with measurements to test the feasibility of defect identification. Finally, the use of LET measurements to estimate of the electrical conductors under test are described as well.

  18. Measurement of thermal conductivity of uranium metal using transient plane source technique

    International Nuclear Information System (INIS)

    Subramanian, G.G.S.; Bapuji, T.; Panneerselvam, G.; Antony, M.P.; Nagarajan, K.

    2012-01-01

    Thermo physical properties of fuel, cladding and structural materials play a significant role in the reactor operation. Thermal conductivity is one of the most important physical properties of the fuel which determines the maximum linear heat rating of the fuel in a reactor. As part of this study, the thermal conductivity of uranium metal was measured using a transient plane source (TPS) by Hot-disc method

  19. Transient Variable Caching in Java’s Stack-Based Intermediate Representation

    Directory of Open Access Journals (Sweden)

    Paul Týma

    1999-01-01

    Full Text Available Java’s stack‐based intermediate representation (IR is typically coerced to execute on register‐based architectures. Unoptimized compiled code dutifully replicates transient variable usage designated by the programmer and common optimization practices tend to introduce further usage (i.e., CSE, Loop‐invariant Code Motion, etc.. On register based machines, often transient variables are cached within registers (when available saving the expense of actually accessing memory. Unfortunately, in stack‐based environments because of the need to push and pop the transient values, further performance improvement is possible. This paper presents Transient Variable Caching (TVC, a technique for eliminating transient variable overhead whenever possible. This optimization would find a likely home in optimizers attached to the back of popular Java compilers. Side effects of the algorithm include significant instruction reordering and introduction of many stack‐manipulation operations. This combination has proven to greatly impede the ability to decompile stack‐based IR code sequences. The code that results from the transform is faster, smaller, and greatly impedes decompilation.

  20. Application of transient analysis methodology to heat exchanger performance monitoring

    International Nuclear Information System (INIS)

    Rampall, I.; Soler, A.I.; Singh, K.P.; Scott, B.H.

    1994-01-01

    A transient testing technique is developed to evaluate the thermal performance of industrial scale heat exchangers. A Galerkin-based numerical method with a choice of spectral basis elements to account for spatial temperature variations in heat exchangers is developed to solve the transient heat exchanger model equations. Testing a heat exchanger in the transient state may be the only viable alternative where conventional steady state testing procedures are impossible or infeasible. For example, this methodology is particularly suited to the determination of fouling levels in component cooling water system heat exchangers in nuclear power plants. The heat load on these so-called component coolers under steady state conditions is too small to permit meaningful testing. An adequate heat load develops immediately after a reactor shutdown when the exchanger inlet temperatures are highly time-dependent. The application of the analysis methodology is illustrated herein with reference to an in-situ transient testing carried out at a nuclear power plant. The method, however, is applicable to any transient testing application

  1. Transient FDTD simulation validation

    OpenAIRE

    Jauregui Tellería, Ricardo; Riu Costa, Pere Joan; Silva Martínez, Fernando

    2010-01-01

    In computational electromagnetic simulations, most validation methods have been developed until now to be used in the frequency domain. However, the EMC analysis of the systems in the frequency domain many times is not enough to evaluate the immunity of current communication devices. Based on several studies, in this paper we propose an alternative method of validation of the transients in time domain allowing a rapid and objective quantification of the simulations results.

  2. Performance of neutron kinetics models for ADS transient analyses

    International Nuclear Information System (INIS)

    Rineiski, A.; Maschek, W.; Rimpault, G.

    2002-01-01

    Within the framework of the SIMMER code development, neutron kinetics models for simulating transients and hypothetical accidents in advanced reactor systems, in particular in Accelerator Driven Systems (ADSs), have been developed at FZK/IKET in cooperation with CE Cadarache. SIMMER is a fluid-dynamics/thermal-hydraulics code, coupled with a structure model and a space-, time- and energy-dependent neutronics module for analyzing transients and accidents. The advanced kinetics models have also been implemented into KIN3D, a module of the VARIANT/TGV code (stand-alone neutron kinetics) for broadening application and for testing and benchmarking. In the paper, a short review of the SIMMER and KIN3D neutron kinetics models is given. Some typical transients related to ADS perturbations are analyzed. The general models of SIMMER and KIN3D are compared with more simple techniques developed in the context of this work to get a better understanding of the specifics of transients in subcritical systems and to estimate the performance of different kinetics options. These comparisons may also help in elaborating new kinetics models and extending existing computation tools for ADS transient analyses. The traditional point-kinetics model may give rather inaccurate transient reaction rate distributions in an ADS even if the material configuration does not change significantly. This inaccuracy is not related to the problem of choosing a 'right' weighting function: the point-kinetics model with any weighting function cannot take into account pronounced flux shape variations related to possible significant changes in the criticality level or to fast beam trips. To improve the accuracy of the point-kinetics option for slow transients, we have introduced a correction factor technique. The related analyses give a better understanding of 'long-timescale' kinetics phenomena in the subcritical domain and help to evaluate the performance of the quasi-static scheme in a particular case. One

  3. Dynamic remedial action scheme using online transient stability analysis

    Science.gov (United States)

    Shrestha, Arun

    Economic pressure and environmental factors have forced the modern power systems to operate closer to their stability limits. However, maintaining transient stability is a fundamental requirement for the operation of interconnected power systems. In North America, power systems are planned and operated to withstand the loss of any single or multiple elements without violating North American Electric Reliability Corporation (NERC) system performance criteria. For a contingency resulting in the loss of multiple elements (Category C), emergency transient stability controls may be necessary to stabilize the power system. Emergency control is designed to sense abnormal conditions and subsequently take pre-determined remedial actions to prevent instability. Commonly known as either Remedial Action Schemes (RAS) or as Special/System Protection Schemes (SPS), these emergency control approaches have been extensively adopted by utilities. RAS are designed to address specific problems, e.g. to increase power transfer, to provide reactive support, to address generator instability, to limit thermal overloads, etc. Possible remedial actions include generator tripping, load shedding, capacitor and reactor switching, static VAR control, etc. Among various RAS types, generation shedding is the most effective and widely used emergency control means for maintaining system stability. In this dissertation, an optimal power flow (OPF)-based generation-shedding RAS is proposed. This scheme uses online transient stability calculation and generator cost function to determine appropriate remedial actions. For transient stability calculation, SIngle Machine Equivalent (SIME) technique is used, which reduces the multimachine power system model to a One-Machine Infinite Bus (OMIB) equivalent and identifies critical machines. Unlike conventional RAS, which are designed using offline simulations, online stability calculations make the proposed RAS dynamic and adapting to any power system

  4. Anticipated transients without scram for light water reactors

    International Nuclear Information System (INIS)

    1978-12-01

    In the first two volumes of this report, Anticipated Transients without Scram for Light Water Reactors NUREG-0460, dated April 1978, the NRC staff reviewed the information on this subject that had been developed in the past and evaluated the susceptibility of current nuclear plants to ATWS events using fault tree/event tree analysis techniques. Based on that evaluation, the staff concluded that some corrective measures were required to reduce the risk of severe consequences arising from possible ATWS events. Since the issuance of NUREG-0460, new safety and cost information has become available on ATWS. Also, new insights have been developed on the general subject of quantitative risk assessment. The purpose of this supplement to NUREG-0460 is to summarize the important additions to the information base and to propose a course of action from among a variety of alternatives for resolving the ATWS concern

  5. Transient electromagnetic analysis in tokamaks using TYPHOON code

    International Nuclear Information System (INIS)

    Belov, A.V.; Duke, A.E.; Korolkov, M.D.; Kotov, V.L.; Kukhtin, V.P.; Lamzin, E.A.; Sytchevsky, S.E.

    1996-01-01

    The transient electromagnetic analysis of conducting structures in tokamaks is presented. This analysis is based on a three-dimensional thin conducting shell model. The finite element method has been used to solve the corresponding integrodifferential equation. The code TYPHOON has been developed to calculate transient processes in tokamaks. Calculation tests and the code verification have been carried out. The calculation results of eddy current and force distibution and a.c. losses for different construction elements for both ITER and TEXTOR tokamaks magnetic systems are presented. (orig.)

  6. Current activities in development of PIE techniques in JMTR hot laboratory

    International Nuclear Information System (INIS)

    Ishii, Toshimitsu; Ohmi, Masao; Shimizu, Michio; Kaji, Yoshiyuki; Ueno, Fumiyoshi

    2006-01-01

    A wide variety of post-irradiation examinations (PIEs) for research and development of nuclear fuels and materials to be utilized in nuclear field has been carried out since 1971 in three kinds of β-γ hot cells; concrete, lead and steel cells in the JMTR Hot Laboratory (JMTR HL) associated with the Japan Materials Testing Reactor (JMTR). In addition to PIEs, the re-capsuling work including re-instrumentation was also conducted for the power ramping tests of the irradiated LWR fuels using Boiling Water Capsule (BOCA). Recently, new PIE techniques are required for the advanced irradiation studies. In this paper, the irradiation assisted stress corrosion cracking (IASCC) growth test technique of irradiated in-core structural materials and the remote operation technique of the atomic force microscope (AFM) are described as JMTR HL's current activities in the development of new PIE techniques. (author)

  7. Capacitor current feedback for output filter damping in switched-mode magnet power supplies

    International Nuclear Information System (INIS)

    Paven Kumar, M.R.; Kim, J.M.S.

    1994-01-01

    In magnet power supplies for a particle accelerator system, a second-order low-pass filter is used to reduce the output current ripple content within specifications. The output filter must be properly damped in order to avoid any large amplification at the resonant frequency and large transient responses of voltages and currents at the step change of the line voltage. Conventionally, a series combination of resistance and capacitance is added in parallel with the filter capacitor to provide the required damping. This approach, however, requires a large dc-blocking capacitor which has to be several times larger than the filter capacitor. In this paper, a filter damping technique using capacitor current feedback is presented. The basic concept of the capacitor current feedback is established using a linear model of the converter involved, and then a sampled-data model of the converter is used to analyze the filter damping technique. The filter damping effect of the capacitor current feedback is verified experimentally

  8. Molten fuel motion during a fast-reactor overpower transient

    International Nuclear Information System (INIS)

    Kolesar, D.C.; Padilla, A. Jr.; Lewis, C.H.; Waltar, A.E.

    1976-01-01

    Mechanistic models for postfailure fuel behavior during hypothetical transient overpower accidents are currently being developed for incorporation into the MELT accident analysis code. A new model for the fuel-coolant interaction and for the motion of fuel in the coolant channel has been developed and incorporated into the MELT-III code. A major limitation of the mechanistic fuel motion model is its dependence on the uniform interaction region of MELT-III. Consequently, a parallel effort is currently in progress to incorporate a non-uniform interaction region into the MELT code. Combination of the fuel motion and the nonuniform interaction region models will provide the framework for development of a mechanistic fuel plateout/blockage model for transient overpower accidents

  9. Correlation between photoconductivity in nanocrystalline titania and short circuit current transients in MEH-PPV/titania solar cells

    International Nuclear Information System (INIS)

    Xie, Z B; Henry, B M; Kirov, K R; Barkhouse, D A R; Burlakov, V M; Smith, H E; Grovenor, C R M; Assender, H E; Briggs, G A D; Kano, M; Tsukahara, Y

    2007-01-01

    We report the first experimental observation of a direct relationship between electron transport in different nanocrystalline TiO 2 thin films and the photovoltaic performance of TiO 2 /MEH-PPV composite solar cells made using these same TiO 2 films. We show that the transient behaviour in the composite solar cells under illumination can be explained by the transient photoconductivity performance of the TiO 2 layer

  10. Twenty-five years of transient counting experience in French PWR units

    Energy Technology Data Exchange (ETDEWEB)

    Barthelet, B. [Electricite de France (EDF DPN), 93 - Saint-Denis (France); Savoldelli, D.; Fritz, R. [Electricite de France (EDF DPN), 93 - Noisy le Grand (France)

    2001-07-01

    For nearly twenty five years, EDF has been checking that the actual operating transients are neither more severe nor more numerous than the design basis transients. This activity of transient cycle counting and bookkeeping has enabled EDF to own a database of more than 800 reactor.years for the PWR units. The current method of transient cycle counting is presented. In the paper, we will point out the main results of transient cycle counting and lessons learned. In general, the frequencies of transients are lower than the design frequencies. In few cases, they are higher, such as the transient frequencies of the RCS lines connected to auxiliary systems often due to operating procedures or particular periodic testing. Few periodic tests were not taken into account in the design basis transient file ; they have been detected thanks to the transient cycle counting. In the last 1980's, we achieved the first updating of the design basis transient file for the PWR 900 MWe series. In the early 1990's, we updated the design basis transient file of the PWR 1300 MWe series. In fact, since design and start-up, the operating conditions have been modified (fuel cycle with stretch-out, modification of the hot leg and cold leg temperatures for the PWR 1300 MWe,...). This was the cause of many unclassified transients. In the new design basis transient file, we have created new transients and increased the frequencies of some of them. This has enabled to consider the updated design basis transient file more representative of actual operating transients. For some years, we have increasingly associated the operators with the transient cycle counting concern. We noticed progress (decreased frequencies of most transients). (authors)

  11. Twenty-five years of transient counting experience in French PWR units

    International Nuclear Information System (INIS)

    Barthelet, B.; Savoldelli, D.; Fritz, R.

    2001-01-01

    For nearly twenty five years, EDF has been checking that the actual operating transients are neither more severe nor more numerous than the design basis transients. This activity of transient cycle counting and bookkeeping has enabled EDF to own a database of more than 800 reactor.years for the PWR units. The current method of transient cycle counting is presented. In the paper, we will point out the main results of transient cycle counting and lessons learned. In general, the frequencies of transients are lower than the design frequencies. In few cases, they are higher, such as the transient frequencies of the RCS lines connected to auxiliary systems often due to operating procedures or particular periodic testing. Few periodic tests were not taken into account in the design basis transient file ; they have been detected thanks to the transient cycle counting. In the last 1980's, we achieved the first updating of the design basis transient file for the PWR 900 MWe series. In the early 1990's, we updated the design basis transient file of the PWR 1300 MWe series. In fact, since design and start-up, the operating conditions have been modified (fuel cycle with stretch-out, modification of the hot leg and cold leg temperatures for the PWR 1300 MWe,...). This was the cause of many unclassified transients. In the new design basis transient file, we have created new transients and increased the frequencies of some of them. This has enabled to consider the updated design basis transient file more representative of actual operating transients. For some years, we have increasingly associated the operators with the transient cycle counting concern. We noticed progress (decreased frequencies of most transients). (authors)

  12. Instrumented Taylor anvil-on-rod impact tests for validating applicability of standard strength models to transient deformation states

    Science.gov (United States)

    Eakins, D. E.; Thadhani, N. N.

    2006-10-01

    Instrumented Taylor anvil-on-rod impact tests have been conducted on oxygen-free electronic copper to validate the accuracy of current strength models for predicting transient states during dynamic deformation events. The experiments coupled the use of high-speed digital photography to record the transient deformation states and laser interferometry to monitor the sample back (free surface) velocity as a measure of the elastic/plastic wave propagation through the sample length. Numerical continuum dynamics simulations of the impact and plastic wave propagation employing the Johnson-Cook [Proceedings of the Seventh International Symposium on Ballistics, 1983, The Netherlands (Am. Def. Prep. Assoc. (ADPA)), pp. 541-547], Zerilli-Armstrong [J. Appl. Phys. C1, 1816 (1987)], and Steinberg-Guinan [J. Appl. Phys. 51, 1498 (1980)] constitutive equations were used to generate transient deformation profiles and the free surface velocity traces. While these simulations showed good correlation with the measured free surface velocity traces and the final deformed sample shape, varying degrees of deviations were observed between the photographed and calculated specimen profiles at intermediate deformation states. The results illustrate the usefulness of the instrumented Taylor anvil-on-rod impact technique for validating constitutive equations that can describe the path-dependent deformation response and can therefore predict the transient and final deformation states.

  13. Static converters power supply: transient regimes; Alimentation par convertisseurs statiques: regimes transitoires

    Energy Technology Data Exchange (ETDEWEB)

    Pasqualini, G. [Ecole Superieure d`Electricite (France)

    1997-08-01

    Direct current motors, asynchronous and variable speed synchronous motors are generally supplied with static converters. Speed variation is obtained by voltage variation in DC motors and by frequency variation in AC motors. In these conditions, these motors are running continuously in transient regimes: the DC motors current is not direct and the AC motors current is not sinusoidal. This situation leads to pulsing couples in the shaft line and to an increase of Joule effect losses. The aim of this paper is to present the methods of study of the electric motors functioning using the shape of the power voltages given by converters and mathematical models of these machines. The synchronous machines are rapidly described while the asynchronous machines are studied using Ku`s transformation instead of Park`s transformation for simplification. For each type of machine, calculation methods allow to determine their current, additional losses and couple characteristics. The transient regimes considered are those remaining when the motor is running at a constant speed and defined regime (supply voltages are periodical functions of time). These transient regimes are identically reproducing with a frequency which is a multiple of the converters supply frequency. Transient regimes due to functioning changes of the motor, such as resisting couple or power supply frequency variations, are not considered in this study. (J.S.) 9 refs.

  14. Transient and localized processes in the magnetotail: a review

    Directory of Open Access Journals (Sweden)

    A. S. Sharma

    2008-05-01

    Full Text Available Many phenomena in the Earth's magnetotail have characteristic temporal scales of several minutes and spatial scales of a few Earth radii (RE. Examples of such transient and localized mesoscale phenomena are bursty bulk flows, beamlets, energy dispersed ion beams, flux ropes, traveling compression regions, night-side flux transfer events, and rapid flappings of the current sheet. Although most of these observations are linked to specific interpretations or theoretical models they are inter-related and can be the different aspects of a physical process or origin. Recognizing the inter-connected nature of the different transient and localized phenomena in the magnetotail, this paper reviews their observations by highlighting their important characteristics, with emphasis on the new results from Cluster multipoint observations. The multi-point Cluster measurements have provided, for the first time, the ability to distinguish between temporal and spatial variations, and to resolve spatial structures. Some examples of the new results are: flux ropes with widths of 0.3 RE, transient field aligned currents associated with bursty bulk flows and connected to the Hall current at the magnetic reconnection, flappings of the magnetotail current sheet with time scales of 100 s–10 min and thickness of few thousand km, and particle energization including velocity and time dispersed ion structures with the latter having durations of 1–3 min. The current theories of these transient and localized processes are based largely on magnetic reconnection, although the important role of the interchange and other plasma modes are now well recognized. On the kinetic scale, the energization of particles takes place near the magnetic X-point by non-adiabatic processes and wave-particle interactions. The theory, modeling and simulations of the plasma and field signatures are reviewed and the links among the different observational

  15. Transient and localized processes in the magnetotail: a review

    Directory of Open Access Journals (Sweden)

    A. S. Sharma

    2008-05-01

    Full Text Available Many phenomena in the Earth's magnetotail have characteristic temporal scales of several minutes and spatial scales of a few Earth radii (RE. Examples of such transient and localized mesoscale phenomena are bursty bulk flows, beamlets, energy dispersed ion beams, flux ropes, traveling compression regions, night-side flux transfer events, and rapid flappings of the current sheet. Although most of these observations are linked to specific interpretations or theoretical models they are inter-related and can be the different aspects of a physical process or origin. Recognizing the inter-connected nature of the different transient and localized phenomena in the magnetotail, this paper reviews their observations by highlighting their important characteristics, with emphasis on the new results from Cluster multipoint observations. The multi-point Cluster measurements have provided, for the first time, the ability to distinguish between temporal and spatial variations, and to resolve spatial structures. Some examples of the new results are: flux ropes with widths of 0.3 RE, transient field aligned currents associated with bursty bulk flows and connected to the Hall current at the magnetic reconnection, flappings of the magnetotail current sheet with time scales of 100 s–10 min and thickness of few thousand km, and particle energization including velocity and time dispersed ion structures with the latter having durations of 1–3 min. The current theories of these transient and localized processes are based largely on magnetic reconnection, although the important role of the interchange and other plasma modes are now well recognized. On the kinetic scale, the energization of particles takes place near the magnetic X-point by non-adiabatic processes and wave-particle interactions. The theory, modeling and simulations of the plasma and field signatures are reviewed and the links among the different observational concepts and the theoretical frameworks

  16. Influence of Current Transformer Saturation on Operation of Current Protection

    Directory of Open Access Journals (Sweden)

    F. A. Romaniouk

    2010-01-01

    Full Text Available An analysis of the influence of instrument current transformer errors on operation of current protection of power supply diagram elements has been carried out in the paper. The paper shows the influence of an aperiodic component of transient current and secondary load on current  transformer errors.Peculiar operational features of measuring elements of electromechanical and microprocessor current protection with their joint operation with electromagnetic current transformers have been analyzed in the paper.

  17. Characteristic behavior of bubbles and slugs in transient two-phase flow using image-processing method

    International Nuclear Information System (INIS)

    Goto, Shoji; Ishizaki, Yasuo; Ohashi, Hirotada; Akiyama, Mamoru

    1995-01-01

    Simulation of transient two-phase flow has been performed by solving transient hydrodynamic equations. However, constitution relations used in this simulation are primarily based on steady-state experimental results. Thus it is important to understand the transient behavior of bubbles and slugs, in particular, transient behavior of the void fraction, the interfacial area and the flow pattern, to confirm the applicability of the present simulation method and to advance two-phase flow simulation further. The present study deals with measurement of transient two-phase flow. We have measured local and instantaneous void fractions using imaging techniques, and compared the experimental data with simulation results. (author)

  18. Transients of Water Distribution and Transport in PEFCs

    KAUST Repository

    Hussaini, Irfan

    2008-01-01

    Response of PEM fuel cells to a step-change in load is investigated experimentally in this work. Voltage undershoot, a characteristic feature of such transient response, is shown to be due to transients of water distribution in membrane phase occurring at sub-second time scales. Use of humidified reactants as a means to control magnitude of voltage undershoot has been demonstrated. Constant stoichiometry operation under certain current-step conditions is found to result in reactant starvation, potentially leading to cell shut down. Further, response under step decrease in current density has been explored to determine existence of hysteresis. Under sufficiently humidified conditions, response under forward and reverse step changes are found to be symmetric, but under low RH conditions, voltage undershoot is found to be twice as large as the overshoot. © The Electrochemical Society.

  19. Prismatic Core Coupled Transient Benchmark

    International Nuclear Information System (INIS)

    Ortensi, J.; Pope, M.A.; Strydom, G.; Sen, R.S.; DeHart, M.D.; Gougar, H.D.; Ellis, C.; Baxter, A.; Seker, V.; Downar, T.J.; Vierow, K.; Ivanov, K.

    2011-01-01

    The Prismatic Modular Reactor (PMR) is one of the High Temperature Reactor (HTR) design concepts that have existed for some time. Several prismatic units have operated in the world (DRAGON, Fort St. Vrain, Peach Bottom) and one unit is still in operation (HTTR). The deterministic neutronics and thermal-fluids transient analysis tools and methods currently available for the design and analysis of PMRs have lagged behind the state of the art compared to LWR reactor technologies. This has motivated the development of more accurate and efficient tools for the design and safety evaluations of the PMR. In addition to the work invested in new methods, it is essential to develop appropriate benchmarks to verify and validate the new methods in computer codes. The purpose of this benchmark is to establish a well-defined problem, based on a common given set of data, to compare methods and tools in core simulation and thermal hydraulics analysis with a specific focus on transient events. The benchmark-working group is currently seeking OECD/NEA sponsorship. This benchmark is being pursued and is heavily based on the success of the PBMR-400 exercise.

  20. Bright PanSTARRS Nuclear Transients – what are they?

    Directory of Open Access Journals (Sweden)

    Smartt S.

    2012-12-01

    Full Text Available We present an initial analysis of 49 bright transients occurring in the nuclei of galaxies with no previous known Active Galactic Nucleus (AGN. They have been discovered as part of the PanSTARRs 3π survey, and followed up with the Liverpool Telescope. Based on colours, light curve shape, and a small number with optical spectra, these transients seem to fall into three groups. Red/fast transients are nuclear supernovae of various types. Some bright nuclear transients are blue and decay on a timescale of a few months; these may be candidates for tidal disruption events. However most of the events we have found are blue and are either still rising or decaying slowly, on a timescale of years; the few spectra we have show AGN at z ∼ 1. We argue that these transients are background AGN microlensed by stars in foreground galaxies by a factor 10–100. Monitoring such events gives us very promising prospects for measuring the structure of AGN and so testing current theories.

  1. A Technique to Estimate the Equivalent Loss Resistance of Grid-Tied Converters for Current Control Analysis and Design

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Fernandez, Francisco Daniel Freijedo

    2015-01-01

    Rigorous analysis and design of the current control loop in voltage source converters (VSCs) requires an accurate modeling. The loop behavior can be significantly influenced by the VSC working conditions. To consider such effect, converter losses should be included in the model, which can be done...... by means of an equivalent series resistance. This paper proposes a method to identify the VSC equivalent loss resistance for the proper tuning of the current control loop. It is based on analysis of the closed-loop transient response provided by a synchronous proportional-integral current controller......, according to the internal model principle. The method gives a set of loss resistance values linked to working conditions, which can be used to improve the tuning of the current controllers, either by online adaptation of the controller gains or by open-loop adaptive adjustment of them according to prestored...

  2. Experimental and mathematical simulation techniques for determining an in-situ response testing method for neutron sensors used in reactor power plant protection systems

    International Nuclear Information System (INIS)

    Behbahani, A.

    1983-01-01

    An analytical neutron sensor response model and methods for transient response measurements of neutron sensors (compensated ionization chamber), including possible in-situ techniques have been developed and evaluated to meet the provisions of Draft Standard ISA Sd67.06, IEEE 338-1977, and NRC Guide 1.118. One in-situ method requires the perturbation of the high voltage detector (sensor) power supply and measurement of the sensor response. The response to a perturbation of the power supply is related to the response of the sensor to a transient change in neutron flux. Random signal analysis is another in-situ technique to monitor the neutron sensor response. In this method the power spectrum of the inherent fluctuations from the neutron sensor output (current in CIC) are measured and evaluated. Transient response techniques (including in-situ methods) are experimentally and analytically evaluated to identify the mechanisms which may cause degradation in the response of the neutron sensors. The objective of the experimental evaluation was to correlate the measured response time using transient radiation flux changes and power supply perturbation. The objective of the analytical model of the different sensor response was to predict response time and degradation mechanisms

  3. Transient analysis of carbon monoxide transport phenomena and adsorption kinetics in HT-PEMFC during dynamic current extraction

    International Nuclear Information System (INIS)

    Raj, Kamal Abdul Rasheedj; Chan, Siew Hwa

    2015-01-01

    Highlights: • Increasing the fuel cell temperature reduces outlet CO concentration. • Increasing the CO inlet (initial) concentration increases outlet CO concentration. • Increasing current density step and dwell time increases outlet CO concentration. • Increasing in the CL and GDL porosities reduces outlet CO concentration. - Abstract: This paper investigates the transport phenomena of carbon monoxide (CO) and adsorption kinetics, in a high-temperature proton exchange membrane fuel cell (HT-PEMFC) during step-wise current extraction (step-change in current extraction). Step-wise current extraction is a common process done to accommodate a sudden power surge during an operation. Since HT-PEMFCs are capable of handling high impurity of CO, hydrogen fuel that is contaminated with trace amount of CO is usually considered for commercial benefits. Thus, a transient three-dimensional isothermal anodic electro-kinetic numerical model is developed to determine the effect of operating parameters such as fuel cell temperature, CO inlet (initial) concentration, step-change of current density and dwell time on the transport phenomena of CO and adsorption kinetics. In addition, geometrical factors such as the catalyst layer (CL) and gas diffusion layer (GDL) porosity are also varied as well. The results show that the above-mentioned operating parameters can affect the maximum CO concentration at the CL, especially at the outlet of the channel. Specifically, a reduction of fuel cell temperature can significantly increase the CO concentration near the outlet, while increasing CO inlet (initial) concentration, step-change amplitude of current density and current density dwell time can cause an increase in CO concentration at the outlet, albeit to different extent. In addition, the increase in the porosity of CL and GDL, results in the reduction of the maximum CO concentration at the outlet, albeit to different extent. In addition, the CO and hydrogen surface coverage

  4. Transient Go: A Mobile App for Transient Astronomy Outreach

    Science.gov (United States)

    Crichton, D.; Mahabal, A.; Djorgovski, S. G.; Drake, A.; Early, J.; Ivezic, Z.; Jacoby, S.; Kanbur, S.

    2016-12-01

    Augmented Reality (AR) is set to revolutionize human interaction with the real world as demonstrated by the phenomenal success of `Pokemon Go'. That very technology can be used to rekindle the interest in science at the school level. We are in the process of developing a prototype app based on sky maps that will use AR to introduce different classes of astronomical transients to students as they are discovered i.e. in real-time. This will involve transient streams from surveys such as the Catalina Real-time Transient Survey (CRTS) today and the Large Synoptic Survey Telescope (LSST) in the near future. The transient streams will be combined with archival and latest image cut-outs and other auxiliary data as well as historical and statistical perspectives on each of the transient types being served. Such an app could easily be adapted to work with various NASA missions and NSF projects to enrich the student experience.

  5. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  6. Eddy current technique for detecting and sizing surface cracks in steel components

    International Nuclear Information System (INIS)

    Cecco, V.S.; Carter, J.R.; Sullivan, S.P.

    1995-01-01

    Cracking has occurred in pressure vessel nozzles and girth welds due to thermal fatigue. Pipe welds, welds in support structures, and welds in reactor vault liner panels in nuclear facilities have failed because of cracks. Cracking can also occur in turbine rotor bore surfaces due to high cycle fatigue. Dye penetrant, magnetic particle and other surface NDT methods are used to detect cracks but cannot be used for depth sizing. Crack depth can be measured with various NDT methods such as ultrasonic time-of-flight diffraction (TOFD), potential drop, and eddy current. The TOFD technique can be difficult to implement on nozzle welds and is best suited for sizing deep cracks (>5 mm). The conventional eddy current method is easy to implement, but crack sizing is normally limited to shallow cracks ( 2 mm) cracks. Eddy current testing (ET) techniques are readily amenable to remote/automatic inspections. These new probes could augment present magnetic particle (MT) and dye penetrant (PT) testing through provision of reliable defect depth information. Reliable crack sizing permits identification of critical cracks for plant life extension and licensing purposes. In addition, performing PT and MT generates low level radioactive waste in some inspection applications in nuclear facilities. Replacing these techniques with ET for some components will eliminate some of this radioactive waste. (author)

  7. Segregated copper ratio experiment on transient stability (SeCRETS). Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Bruzzone, P. [ed.] [Ecole Polytechnique Federale de Lausanne, Centre de Recherches en Physique des Plasmas (CRPP), CH-1015 Lausanne (Switzerland)

    2001-01-01

    Two Nb{sub 3}Sn, steel jacketed, cable-in-conduit conductors have been manufactured with identical non-Cu cross sections and the stabilizer either included in the Nb{sub 3}Sn composite or partly segregated as copper wires. The two conductors are series connected and wound as a bifilar , single layer solenoid, assembled in the high field bore (11 T) of the SULTAN test facility. The operating current is up to 12 kA (400 A/mm{sup 2}). A transverse pulsed field is applied with {delta}B up to 2.7 T, field rate up to 180 T/s and field integral up to 530 T{sup 2}/s. In the dc test, a good agreement is found between the I{sub c} and the T{sub cs} results, both correctly scaling according to the parameters derived from the strand tests. The n-value from the V-I curve is in the range of 15. The current sharing at the high field section is correlated with a local current re-distribution, observed by arrays of miniature Hall sensors, detecting the self-field around the conductor. The ac losses results in the range of 2 to 9 Hz by gas flow calorimetry indicate coupling currents constant, n{tau}, in the range of 1.5 ms at high field, increasing by a factor of 2 with 12 kA transport current. Loss extrapolation to 0 frequency suggests that the loss curve may be not linear outside the test range, with higher n{tau} at lower field rate. The calorimetric loss estimation at the fast field transient (f=15 Hz) indicates n{tau} {approx_equal} 2 ms. The ITER plasma disruption transients have been reproduced by the pulsed coils. Due to the very low ac losses, no quench could be generated in either conductor even reducing the temperature margin below 0.2-0.3 K. Very large field transients, with integral above 100 T{sup 2}/s, are required to quench the conductors. In that range, the conductor without segregated copper has superior performance. Due to the large interstrand resistance (very low ac losses), the segregated copper has marginal contribution to the stability. No evidence of current

  8. Current techniques in postmortem imaging with specific attention to paediatric applications

    Energy Technology Data Exchange (ETDEWEB)

    Sieswerda-Hoogendoorn, Tessa; Rijn, Rick R. van [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam Zuid-Oost (Netherlands); Netherlands Forensic Institute, Department of Pathology and Toxicology, The Hague (Netherlands)

    2010-02-15

    In this review we discuss the decline of and current controversies regarding conventional autopsies and the use of postmortem radiology as an adjunct to and a possible alternative for the conventional autopsy. We will address the radiological techniques and applications for postmortem imaging in children. (orig.)

  9. Current techniques in postmortem imaging with specific attention to paediatric applications

    International Nuclear Information System (INIS)

    Sieswerda-Hoogendoorn, Tessa; Rijn, Rick R. van

    2010-01-01

    In this review we discuss the decline of and current controversies regarding conventional autopsies and the use of postmortem radiology as an adjunct to and a possible alternative for the conventional autopsy. We will address the radiological techniques and applications for postmortem imaging in children. (orig.)

  10. The development of a transient neutron flux solution in the PANTHER code

    International Nuclear Information System (INIS)

    Hutt, P.K.; Knight, M.P.

    1990-01-01

    In the United Kingdom a new three-dimensional, two-group, homogeneous reactor diffusion code, PANTHER, has been developed for the analysis of pressurized water reactors (PWRs) and advanced gas-cooled reactors (AGRs). The code can perform a comprehensive range of calculations, steady state, depletion, and transient with either a finite difference or analytic nodal flux solution. The nodal solution allows the representation of within-node burnup variation and pin-power reconstruction in either steady-state or transient mode. Specific steady-state and transient thermal feedback modules are included for both PWRs and AGRs. The code is being developed to perform a complete range of reactor calculations from online operational support to fuel management and fault transient analysis. In the area of transient analysis, the code is currently being used for a number of PWR fault transient assessments, including rod ejection and steam-line break. In addition, work is proceeding to incorporate the PANTHER 3D nodal transient solution in the TRAC-P code. This paper outlines the development of the transient flux solutions within PANTHER

  11. Do Magnetic Fields drive high-energy explosive transients?

    OpenAIRE

    Mundell, Carole

    2017-01-01

    I will review the current state-of-the-art in real-time, rapid response optical imaging and polarimetric followup of transient sources such as Gamma Ray Bursts. I will interpret current results within the context of the external shock model and present predictions for future mm- and cm-wave radio observatories. Recent observational results from new radio pilot studies will also be presented.

  12. Do Magnetic Fields Drive High-Energy Explosive Transients?

    Science.gov (United States)

    Mundell, Carole

    2017-10-01

    I will review the current state-of-the-art in real-time, rapid response optical imaging and polarimetric followup of transient sources such as Gamma Ray Bursts. I will interpret current results within the context of the external shock model and present predictions for future mm- and cm-wave radio observatories. Recent observational results from new radio pilot studies will also be presented.

  13. Maximum Bandwidth Enhancement of Current Mirror using Series-Resistor and Dynamic Body Bias Technique

    Directory of Open Access Journals (Sweden)

    V. Niranjan

    2014-09-01

    Full Text Available This paper introduces a new approach for enhancing the bandwidth of a low voltage CMOS current mirror. The proposed approach is based on utilizing body effect in a MOS transistor by connecting its gate and bulk terminals together for signal input. This results in boosting the effective transconductance of MOS transistor along with reduction of the threshold voltage. The proposed approach does not affect the DC gain of the current mirror. We demonstrate that the proposed approach features compatibility with widely used series-resistor technique for enhancing the current mirror bandwidth and both techniques have been employed simultaneously for maximum bandwidth enhancement. An important consequence of using both techniques simultaneously is the reduction of the series-resistor value for achieving the same bandwidth. This reduction in value is very attractive because a smaller resistor results in smaller chip area and less noise. PSpice simulation results using 180 nm CMOS technology from TSMC are included to prove the unique results. The proposed current mirror operates at 1Volt consuming only 102 µW and maximum bandwidth extension ratio of 1.85 has been obtained using the proposed approach. Simulation results are in good agreement with analytical predictions.

  14. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  15. Submucosal tunneling techniques: current perspectives.

    Science.gov (United States)

    Kobara, Hideki; Mori, Hirohito; Rafiq, Kazi; Fujihara, Shintaro; Nishiyama, Noriko; Ayaki, Maki; Yachida, Tatsuo; Matsunaga, Tae; Tani, Johji; Miyoshi, Hisaaki; Yoneyama, Hirohito; Morishita, Asahiro; Oryu, Makoto; Iwama, Hisakazu; Masaki, Tsutomu

    2014-01-01

    Advances in endoscopic submucosal dissection include a submucosal tunneling technique, involving the introduction of tunnels into the submucosa. These tunnels permit safer offset entry into the peritoneal cavity for natural orifice transluminal endoscopic surgery. Technical advantages include the visual identification of the layers of the gut, blood vessels, and subepithelial tumors. The creation of a mucosal flap that minimizes air and fluid leakage into the extraluminal cavity can enhance the safety and efficacy of surgery. This submucosal tunneling technique was adapted for esophageal myotomy, culminating in its application to patients with achalasia. This method, known as per oral endoscopic myotomy, has opened up the new discipline of submucosal endoscopic surgery. Other clinical applications of the submucosal tunneling technique include its use in the removal of gastrointestinal subepithelial tumors and endomicroscopy for the diagnosis of functional and motility disorders. This review suggests that the submucosal tunneling technique, involving a mucosal safety flap, can have potential values for future endoscopic developments.

  16. A microcomputer-controlled modulation technique for the detection of transient species in UV photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Lonkhuyzen, H. van; Muller, H.G.; Lange, C.A. de

    1980-01-01

    A microcomputer-controlled modulation method is described to measure UV photoelectron spectra of transient species generated in a microwave discharge. Spectra at low and high microwave power levels are simultaneously recorded and afterwards linearly combined in order to remove parent compound signals. The method is applied to discharged oxygen where the transition O 2 + ( 2 PHIsub(u)) 2 ( 1 Δsub(g)) becomes visible without interference from the parent molecule O 2 ( 3 Σsub(g) - ), and to discharged sulphur dioxide where SO( 3 Σ - ) and S( 3 P) photoelectron spectra are obtained free from SO 2 bands. Finally the build-up of transient bands as a function of time is recorded. (orig.)

  17. Solution of axisymmetric transient inverse heat conduction problems using parameter estimation and multi block methods

    International Nuclear Information System (INIS)

    Azimi, A.; Hannani, S.K.; Farhanieh, B.

    2005-01-01

    In this article, a comparison between two iterative inverse techniques to solve simultaneously two unknown functions of axisymmetric transient inverse heat conduction problems in semi complex geometries is presented. The multi-block structured grid together with blocked-interface nodes is implemented for geometric decomposition of physical domain. Numerical scheme for solution of transient heat conduction equation is the finite element method with frontal technique to solve algebraic system of discrete equations. The inverse heat conduction problem involves simultaneous unknown time varying heat generation and time-space varying boundary condition estimation. Two parameter-estimation techniques are considered, Levenberg-Marquardt scheme and conjugate gradient method with adjoint problem. Numerically computed exact and noisy data are used for the measured transient temperature data needed in the inverse solution. The results of the present study for a configuration including two joined disks with different heights are compared to those of exact heat source and temperature boundary condition, and show good agreement. (author)

  18. Current trends in dextranomer hyaluronic acid copolymer (Deflux) injection technique for endoscopic treatment of vesicoureteral reflux.

    Science.gov (United States)

    Kirsch, Andrew J; Arlen, Angela M; Lackgren, Goran

    2014-08-01

    To determine the current preferred injection technique(s) for endoscopic management of pediatric vesicoureteral reflux (VUR). Since the approval of dextranomer hyaluronic acid copolymer (Dx/HA) in 2001, injection methods have evolved and now include the hydrodistention implantation technique (HIT) and double HIT as well as subureteral transurethral injection (STING) method. In July 2012, 278 pediatric urologists in the United States were contacted to complete a 15-question survey regarding Dx/HA injection technique(s) currently used in their practice. Fifty board-certified pediatric urologists completed the survey for a response rate of 18%. Most respondents (60%) were in a single-specialty group practice, and 12% were affiliated with an academic- or university-based practice. Respondents reported seeing a mean of 159 pediatric patients (range, 40-400 patients) with VUR annually, and 94% used Dx/HA ≥4 times in the past year. Forty-seven respondents (94%) reported using double HIT over the course of their career compared with 36 (72%) for STING and 30 (60%) for HIT (P injection techniques. A significantly higher percentage currently perform double HIT (92%) compared with either STING (24%) or HIT (34%; P <.001). Respondents reported the use of double HIT 15 times more often than STING technique and 5 times more often than HIT during the past 12 months (P <.001). The double HIT method is currently the most commonly performed technique for endoscopic correction of VUR by pediatric urologists in the United States. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Analyses and computer code developments for accident-induced thermohydraulic transients in water-cooled nuclear reactor systems

    International Nuclear Information System (INIS)

    Wulff, W.

    1977-01-01

    A review is presented on the development of analyses and computer codes for the prediction of thermohydraulic transients in nuclear reactor systems. Models for the dynamics of two-phase mixtures are summarized. Principles of process, reactor component and reactor system modeling are presented, as well as the verification of these models by comparing predicted results with experimental data. Codes of major importance are described, which have recently been developed or are presently under development. The characteristics of these codes are presented in terms of governing equations, solution techniques and code structure. Current efforts and problems of code verification are discussed. A summary is presented of advances which are necessary for reducing the conservatism currently implied in reactor hydraulics codes for safety assessment

  20. The transient transpiration heat flux meter

    International Nuclear Information System (INIS)

    Martins, N.; Calisto, H.; Afgan, N.; Leontiev, A.I.

    2006-01-01

    A new heat flux measurement principle, based on the transient response of a transpiration radiometer, is proposed. The measurement principle of current transpiration radiometers is based on a steady-state temperature measurement in a porous element. Since it may typically take several seconds to reach these conditions, there are obvious benefits in reducing the instrument response time. This can be achieved through the analysis of its transient response in order to predict the incident heat flux. In addition, the proposed methodology enables the separate measurement of the radiative and convective components of incident heat fluxes, without compromising the known advantages of transpiration radiometers. The availability of such an instrument may enable the development of advanced monitoring, diagnostic and control systems for thermal equipment

  1. Transient stability analysis with equal-area criterion for out of step ...

    African Journals Online (AJOL)

    user

    *Corresponding Author: e-mail: almoatazabdelaziz@hotmail.com, Tel. ...... Transient stability of power systems: theory and Practice, John Wiley and Sons. ... and protection and new optimization techniques in power systems operation and.

  2. Application of a film flow model to predicting burnout under transient conditions

    International Nuclear Information System (INIS)

    Leslie, D.C.; Kirby, G.J.

    1967-08-01

    The film flow model developed previously has been generalised to transient situations by assuming that only convection is changed by the transient; evaporation, deposition and entrainment are assumed to be unaffected. A computer code TRABUT computes the time behaviour of the mass velocity and the quality by the method of characteristics, and then integrates the film flow equations along the same characteristics until the point of burn-out or zero film flow is reached. The time delay between the onset of a transient and burn-out has been computed both for flux and flow transients. These computations have been compared with those made using the standard local conditions hypothesis. The film flow model gives shorter delays in almost all cases, but the difference would not be detectable with present experimental techniques. (author)

  3. Preliminary analysis of typical transients in fusion driven subcritical system (FDS-I)

    International Nuclear Information System (INIS)

    Bai Yunqing; Ke Yan; Wu Yican

    2007-01-01

    The potential safety characteristic is expected as one of the advantages of fusion-driven subcritical system (FDS-I) for the transmutation and incineration of nuclear waste compared with the critical reactor. Transients of the FDS-I may occur due to the perturbation of external neutron source, the failure of functional device, and the occurrence of the uncontrolled event. As typical transient scenarios, the following cases were analyzed: unprotected plasma overpower (UPOP), unprotected loss of flow (ULOF), unprotected transient overpower (UTOP). The transient analyses for the FDS-I were performed with a coupled two-dimensional thermal-hydraulics and neutronics transient analysis code NTC2D. The negative feedback of reactivity is the interesting safety feature of FDS-I as temperature increase, due to the fuel form of the circulating particle. The present simulation results showed that the current FDS-I design has a resistance against severe transient scenarios. (author)

  4. Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sanghee (Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine (Korea, Republic of)); Yoon, Sang-Wook; Yoo, Seung-Min; Kim, Kyoung Ah; Kim, Sang Heum; Lee, Jong Tae (Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA Univ. (Korea, Republic of)), email: jansons@cha.ac.kr; Ji, Young Geon (Preventive Medicine, CHA Bundang Medical Center, CHA Univ. (Korea, Republic of))

    2011-12-15

    Background. Tube current is an important determinant of radiation dose and image quality in X-ray-based examination. The combined automatic tube current modulation technique (ATCM) enables automatic adjustment of the tube current in various planes (x-y and z) based on the size and attenuation of the body area scanned. Purpose. To compare image quality and radiation dose of the ATCM with those of a fixed tube current technique (FTC) in CT of the abdomen and pelvis performed with a 16-slice multidetector row CT. Material and Methods. We reviewed 100 patients in whom initial and follow-up CT of the abdomen and pelvis were performed with FTC and ATCM. All acquisition parameters were identical in both techniques except for tube current. We recorded objective image noise in liver parenchyma, subjective image noise and diagnostic acceptability by using a five-point scale, radiation dose, and body mass index (BMI, kg/m2). Data were analyzed with parametric and non-parametric statistical tests. Results. There was no significant difference in image noise and diagnostic acceptability between two techniques. All subjects had acceptable subjective image noise in both techniques. The significant reduction in radiation dose (45.25% reduction) was noted with combined ATCM (P < 0.001). There was a significant linear statistical correlation between BMI and dose reduction (r = -0.78, P < 0.05). Conclusion. The ATCM for CT of the abdomen and pelvis substantially reduced radiation dose while maintaining diagnostic image quality. Patients with lower BMI showed more reduction in radiation dose

  5. Predictive modeling of transient storage and nutrient uptake: Implications for stream restoration

    Science.gov (United States)

    O'Connor, Ben L.; Hondzo, Miki; Harvey, Judson W.

    2010-01-01

    This study examined two key aspects of reactive transport modeling for stream restoration purposes: the accuracy of the nutrient spiraling and transient storage models for quantifying reach-scale nutrient uptake, and the ability to quantify transport parameters using measurements and scaling techniques in order to improve upon traditional conservative tracer fitting methods. Nitrate (NO3–) uptake rates inferred using the nutrient spiraling model underestimated the total NO3– mass loss by 82%, which was attributed to the exclusion of dispersion and transient storage. The transient storage model was more accurate with respect to the NO3– mass loss (±20%) and also demonstrated that uptake in the main channel was more significant than in storage zones. Conservative tracer fitting was unable to produce transport parameter estimates for a riffle-pool transition of the study reach, while forward modeling of solute transport using measured/scaled transport parameters matched conservative tracer breakthrough curves for all reaches. Additionally, solute exchange between the main channel and embayment surface storage zones was quantified using first-order theory. These results demonstrate that it is vital to account for transient storage in quantifying nutrient uptake, and the continued development of measurement/scaling techniques is needed for reactive transport modeling of streams with complex hydraulic and geomorphic conditions.

  6. Novel Method for Sizing Metallic Bottom Crack Depth Using Multi-frequency Alternating Current Potential Drop Technique

    OpenAIRE

    Li Yuting; Gan Fangji; Wan Zhengjun; Liao Junbi; Li Wenqiang

    2015-01-01

    Potential drop techniques are of two types: the direct current potential drop (DCPD) technique and alternating current potential drop (ACPD) technique, and both of them are used in nondestructive testing. ACPD, as a kind of valid method in sizing metal cracks, has been applied to evaluate metal structures. However, our review of most available approaches revealed that some improvements can be done in measuring depth of metal bottom crack by means of ACPD, such as accuracy and sensitivity of s...

  7. Computation of the current density in nonlinear materials subjected to large current pulses

    International Nuclear Information System (INIS)

    Hodgdon, M.L.; Hixson, R.S.; Parsons, W.M.

    1991-01-01

    This paper reports that the finite element method and the finite difference method are used to calculate the current distribution in two nonlinear conductors. The first conductor is a small ferromagnetic wire subjected to a current pulse that rises to 10,000 Amperes in 10 microseconds. Results from the transient thermal and transient magnetic solvers of the finite element code FLUX2D are used to compute the current density in the wire. The second conductor is a metal oxide varistor. Maxwell's equations, Ohm's law and the varistor relation for the resistivity and the current density of p = αj -β are used to derive a nonlinear differential equation. The solutions of the differential equation are obtained by a finite difference approximation and a shooting method. The behavior predicted by these calculations is in agreement with experiments

  8. Motor current signature analysis for gearbox condition monitoring under transient speeds using wavelet analysis and dual-level time synchronous averaging

    Science.gov (United States)

    Bravo-Imaz, Inaki; Davari Ardakani, Hossein; Liu, Zongchang; García-Arribas, Alfredo; Arnaiz, Aitor; Lee, Jay

    2017-09-01

    This paper focuses on analyzing motor current signature for fault diagnosis of gearboxes operating under transient speed regimes. Two different strategies are evaluated, extensively tested and compared to analyze the motor current signature in order to implement a condition monitoring system for gearboxes in industrial machinery. A specially designed test bench is used, thoroughly monitored to fully characterize the experiments, in which gears in different health status are tested. The measured signals are analyzed using discrete wavelet decomposition, in different decomposition levels using a range of mother wavelets. Moreover, a dual-level time synchronous averaging analysis is performed on the same signal to compare the performance of the two methods. From both analyses, the relevant features of the signals are extracted and cataloged using a self-organizing map, which allows for an easy detection and classification of the diverse health states of the gears. The results demonstrate the effectiveness of both methods for diagnosing gearbox faults. A slightly better performance was observed for dual-level time synchronous averaging method. Based on the obtained results, the proposed methods can used as effective and reliable condition monitoring procedures for gearbox condition monitoring using only motor current signature.

  9. Transient diagnosis system using quantum-inspired computing and Minkowski distance

    Energy Technology Data Exchange (ETDEWEB)

    Nicolau, Andressa dos Santos; Schirru, Roberto, E-mail: andressa@lmp.ufrj.b, E-mail: schirru@lmp.ufrj.b [Federal University of Rio de Janeiro (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Nuclear Engineering Program

    2011-07-01

    This paper proposes a diagnosis system model for identification of transient in a PWR nuclear power plant, optimized by the Quantum Inspired Evolutionary Algorithm - QEA in order to help nuclear power plant operator reduce his cognitive load and increase his available time to maintain the plant operating in a safe condition. This method was developed in order to be able to recognize the normal condition and three accidents of the design basis list of the nuclear power plant Angra 2, postulated in the Final Safety Analysis Report (FSAR). This System compares the similarly distance between the set of variables of the anomalous event, in a given time t, and the centroids of the design-basis transient variables. The lower similarly distance indicates the class of the transient to which the anomalous event belongs. The QEA was then used to find the best position of the centroids of each class of the selected transients. Such positions maximize the number of the correct classifications. Unlike the diagnosis system proposed in the literature, Minkowski distance was employed to calculate the similarity distance. The signatures of four transients were submitted to 1% and 2% of noise, and tested with prototype vector found by QEA. The results showed that the present transient diagnostic system was successfully implemented in the nuclear accident identification problem and was compatible with the techniques presented in the literature. (author)

  10. Transient diagnosis system using quantum-inspired computing and Minkowski distance

    International Nuclear Information System (INIS)

    Nicolau, Andressa dos Santos; Schirru, Roberto

    2011-01-01

    This paper proposes a diagnosis system model for identification of transient in a PWR nuclear power plant, optimized by the Quantum Inspired Evolutionary Algorithm - QEA in order to help nuclear power plant operator reduce his cognitive load and increase his available time to maintain the plant operating in a safe condition. This method was developed in order to be able to recognize the normal condition and three accidents of the design basis list of the nuclear power plant Angra 2, postulated in the Final Safety Analysis Report (FSAR). This System compares the similarly distance between the set of variables of the anomalous event, in a given time t, and the centroids of the design-basis transient variables. The lower similarly distance indicates the class of the transient to which the anomalous event belongs. The QEA was then used to find the best position of the centroids of each class of the selected transients. Such positions maximize the number of the correct classifications. Unlike the diagnosis system proposed in the literature, Minkowski distance was employed to calculate the similarity distance. The signatures of four transients were submitted to 1% and 2% of noise, and tested with prototype vector found by QEA. The results showed that the present transient diagnostic system was successfully implemented in the nuclear accident identification problem and was compatible with the techniques presented in the literature. (author)

  11. Transient digitizer with displacement current samplers

    Science.gov (United States)

    McEwan, Thomas E.

    1996-01-01

    A low component count, high speed sample gate, and digitizer architecture using the sample gates is based on use of a signal transmission line, a strobe transmission line and a plurality of sample gates connected to the sample transmission line at a plurality of positions. The sample gates include a strobe pickoff structure near the strobe transmission line which generates a charge displacement current in response to propagation of the strobe signal on the strobe transmission line sufficient to trigger the sample gate. The sample gate comprises a two-diode sampling bridge and is connected to a meandered signal transmission line at one end and to a charge-holding cap at the other. The common cathodes are reverse biased. A voltage step is propagated down the strobe transmission line. As the step propagates past a capacitive pickoff, displacement current i=c(dv/dT), flows into the cathodes, driving the bridge into conduction and thereby charging the charge-holding capacitor to a value related to the signal. A charge amplifier converts the charge on the charge-holding capacitor to an output voltage. The sampler is mounted on a printed circuit board, and the sample transmission line and strobe transmission line comprise coplanar microstrips formed on a surface of the substrate. Also, the strobe pickoff structure may comprise a planar pad adjacent the strobe transmission line on the printed circuit board.

  12. Enhancing the capabilities of eddy current techniques for non-destructive evaluation of austenitic stainless steels

    International Nuclear Information System (INIS)

    Rao, B.P.C.; Thirunavukkarasu, S.; Sasi, B.; Jayakumar, T.; Baldev Raj

    2010-01-01

    Eddy current non-destructive evaluation (NDE) techniques find many applications during fabrication and in-service inspection of components made of stainless steel. In recent years, concurrent developments in electromagnetic field detection sensors such as giant magneto-resistive (GMR), giant-magneto impedance (GMI) and SQUIDs sensors, computers, microelectronics, and incorporating advanced signal and image processing techniques, have paved the way for enhancing the capabilities of existing eddy current (EC) techniques for examination of austenitic stainless steel (SS) plates, tubes and other geometries and several innovative methodologies have been developed. This paper highlights a few such applications in EC testing to austenitic stainless steel components used in fast reactors. (author)

  13. Exhaust gas recirculation – Zero dimensional modelling and characterization for transient diesel combustion control

    International Nuclear Information System (INIS)

    Asad, Usman; Tjong, Jimi; Zheng, Ming

    2014-01-01

    Highlights: • Zero-dimensional EGR model for transient diesel combustion control. • Detailed analysis of EGR effects on intake, cylinder charge and exhaust properties. • Intake oxygen validated as an operating condition-independent measure of EGR. • Quantified EGR effectiveness in terms of NOx emission reduction. • Twin lambda sensor technique for estimation of EGR/in-cylinder parameters. - Abstract: The application of exhaust gas recirculation (EGR) during transient engine operation is a challenging task since small fluctuations in EGR may cause larger than acceptable spikes in NOx/soot emissions or deterioration in the combustion efficiency. Moreover, the intake charge dilution at any EGR ratio is a function of engine load and intake pressure, and typically changes during transient events. Therefore, the management of EGR during transient engine operation or advanced combustion cycles (that are inherently less stable) requires a fundamental understanding of the transient EGR behaviour and its impact on the intake charge development. In this work, a zero-dimensional EGR model is described to estimate the transient (cycle-by-cycle) progression of EGR and the time (engine cycles) required for its stabilization. The model response is tuned to a multi-cylinder engine by using an overall engine system time-constant and shown to effectively track the transient EGR changes. The impact of EGR on the actual air–fuel ratio of the cylinder charge is quantified by defining an in-cylinder excess-air ratio that accounts for the oxygen in the recycled exhaust gas. Furthermore, a twin lambda sensor (TLS) technique is implemented for tracking the intake dilution and in-cylinder excess-air ratio in real-time. The modelling and analysis results are validated against a wide range of engine operations, including transient and steady-state low temperature combustion tests

  14. Supraretinacular endoscopic carpal tunnel release: surgical technique with prospective case series.

    Science.gov (United States)

    Ecker, J; Perera, N; Ebert, J

    2015-02-01

    Current techniques for endoscopic carpal tunnel release use an infraretinacular approach, inserting the endoscope deep to the flexor retinaculum. We present a supraretinacular endoscopic carpal tunnel release technique in which a dissecting endoscope is inserted superficial to the flexor retinaculum, which improves vision and the ability to dissect and manipulate the median nerve and tendons during surgery. The motor branch of the median nerve and connections between the median and ulnar nerve can be identified and dissected. Because the endoscope is inserted superficial to the flexor retinaculum, the median nerve is not compressed before division of the retinaculum and, as a result, we have observed no cases of the transient median nerve deficits that have been reported using infraretinacular endoscopic techniques. © The Author(s) 2014.

  15. Advantages and Limitations of Current Imaging Techniques for Characterizing Liposome Morphology

    Directory of Open Access Journals (Sweden)

    Annie-Louise Robson

    2018-02-01

    Full Text Available There are currently a number of imaging techniques available for evaluating the morphology of liposomes and other nanoparticles, with each having its own advantages and disadvantages that should be considered when interpreting data. Controlling and validating the morphology of nanoparticles is of key importance for the effective clinical translation of liposomal formulations. There are a number of physical characteristics of liposomes that determine their in vivo behavior, including size, surface characteristics, lamellarity, and homogeneity. Despite the great importance of the morphology of nanoparticles, it is generally not well-characterized and is difficult to control. Appropriate imaging techniques provide important details regarding the morphological characteristics of nanoparticles, and should be used in conjunction with other methods to assess physicochemical parameters. In this review, we will discuss the advantages and limitations of available imaging techniques used to evaluate liposomal formulations.

  16. Removing fuelling transient using neutron absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Paquette, S.; Chan, P.K.; Bonin, H.W., E-mail: Stephane.Paquette@rmc.ca [Royal Military College of Canada, Chemistry and Chemical Engineering Dept., Kingston, Ontario (Canada); Pant, A. [Cameco Fuel Manufacturing, Port Hope, Ontario (Canada)

    2012-07-01

    Preliminary criticality and burnup calculation results indicate that by employing a small amount of neutron absorber the fuelling transient, currently occurring in a CANDU 37-element fuel bundle, can be significantly reduced. A parametric study using the Los Alamos National Laboratories' MCNP 5 code and Atomic Energy of Canada Limited's WIMS-AECL 3.1 is presented in this paper. (author)

  17. Transient heat transfer for forced convection flow of helium gas

    International Nuclear Information System (INIS)

    Liu, Qiusheng; Fukuda, Katsuya; Sasaki, Kenji; Yamamoto, Manabu

    1999-01-01

    Transient heat transfer coefficients for forced convection flow of helium gas over a horizontal cylinder were measured using a forced convection test loop. The platinum heater with a diameter of 1.0 mm was heated by electric current with an exponential increase of Q 0 exp(t/τ). It was clarified that the heat transfer coefficient approaches the steady-state one for the period τ over 1 s, and it becomes higher for the period of τ shorter than 1 s. The transient heat transfer shows less dependent on the gas flowing velocity when the period becomes very shorter. Semi-empirical correlations for steady-state and transient heat transfer were developed based on the experimental data. (author)

  18. Transient electromagnetic scattering on anisotropic media

    International Nuclear Information System (INIS)

    Stewart, R.D.

    1990-01-01

    This dissertation treats the problem of transient scattering of obliquely incident electromagnetic plane waves on a stratified anisotropic dielectric slab. Scattering operators are derived for the reflective response of the medium. The internal fields are calculated. Wave splitting and invariant imbedding techniques are used. These techniques are first presented for fields normally incident on a stratified, isotropic dielectric medium. The techniques of wave splitting and invariant imbedding are applied to normally incident plane waves on an anisotropic medium. An integro-differential equation is derived for the reflective response and the direct and inverse scattering problems are discussed. These techniques are applied to the case of obliquely incident plane waves. The reflective response is derived and the direct and inverse problems discussed and compared to those for the normal incidence case. The internal fields are investigated for the oblique incidence via a Green's function approach. A numerical scheme is presented to calculate the Green's function. Finally, symmetry relations of the reflective response are discussed

  19. Loss-of-flow transient characterization in carbide-fueled LMFBRs

    International Nuclear Information System (INIS)

    Rothrock, R.B.; Morgan, M.M.; Baars, R.E.; Elson, J.S.; Wray, M.L.

    1985-01-01

    One of the benefits derived from the use of carbide fuel in advanced Liquid Metal Fast Breeder Reactors (LMFBRs) is a decreased vulnerability to certain accidents. This can be achieved through the combination of advanced fuel performance with the enhanced reactivity feedback effects and passive shutdown cooling systems characteristic of the current 'inherently safe' plant concepts. The calculated core response to an unprotected loss of flow (ULOF) accident has frequently been used as a benchmark test of these designs, and the advantages of a high-conductivity fuel in relation to this type of transient have been noted in previous analyses. To evaluate this benefit in carbide-fueled LMFBRs incorporating representative current plant design features, limited calculations have been made of a ULOF transient in a small ('modular') carbide-fueled LMFBR

  20. VEGF attenuated increase of outward delayed-rectifier potassium currents in hippocampal neurons induced by focal ischemia via PI3-K pathway.

    Science.gov (United States)

    Wu, K W; Yang, P; Li, S S; Liu, C W; Sun, F Y

    2015-07-09

    We recently indicated that the vascular endothelial growth factor (VEGF) protects neurons against hypoxic death via enhancement of tyrosine phosphorylation of Kv1.2, an isoform of the delayed-rectifier potassium channels through activation of the phosphatidylinositol 3-kinase (PI3-K) signaling pathway. The present study investigated whether VEGF could attenuate ischemia-induced increase of the potassium currents in the hippocampal pyramidal neurons of rats after ischemic injury. Adult male Sprague-Dawley rats were subjected to transient middle cerebral artery occlusion (MCAO) to induce brain ischemia. The whole-cell patch-clamp technique was used to record the potassium currents of hippocampal neurons in brain slices from the ischemically injured brains of the rats 24h after MCAO. We detected that transient MCAO caused a significant increase of voltage-gated potassium currents (Kv) and outward delayed-rectifier potassium currents (IK), but not outward transient potassium currents (IA), in the ipsilateral hippocampus compared with the sham. Moreover, we found that VEGF could acutely, reversibly and voltage-dependently inhibit the ischemia-induced IK increase. This inhibitory effect of VEGF could be completely abolished by wortmannin, an inhibitor of PI3-K. Our data indicate that VEGF attenuates the ischemia-induced increase of IK via activation of the PI3-K signaling pathway. Published by Elsevier Ltd.

  1. Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and current

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica

    2012-01-01

    , are in some studies considered the main reasons for the variations. This paper presents an experimental study on the quantitative effect of polarisation time and current on the measured polarisation resistance – and thus the corrosion current density – of passively and actively corroding steel. Two...... electrochemical techniques often used in instruments for on-site corrosion rate measurements are investigated. On passively corroding reinforcement the measured polarisation resistance was for both techniques found to be highly affected by the polarisation time and current and no plateaus at either short or long...... rate for actively corroding steel. For both techniques guidelines for polarisation times and currents are given for (on-site) non-destructive corrosion rate measurements on reinforcement steel in concrete....

  2. Analysis of harmonic current interaction in an industrial plant

    NARCIS (Netherlands)

    Cuk, V.; Cobben, J.F.G.; Kling, W.L.; Timens, R.B.

    2011-01-01

    An analysis of current transients caused by the operation of a nearby device in an industrial plant is presented in the paper. The source of current transients in the factory lighting system was traced to the operation of the nearby six-pulse AC/DC converter. To determine the nature of the

  3. Transient effects during erosion of WN by deuterium ions studied with the quartz crystal microbalance technique

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Bernhard M., E-mail: berger@iap.tuwien.ac.at [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Stadlmayr, Reinhard [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Meisl, Gerd [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Čekada, Miha [Jožef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Eisenmenger-Sittner, Christoph [Institute of Solid State Physics, TU Wien, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Schwarz-Selinger, Thomas [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Aumayr, Friedrich, E-mail: aumayr@iap.tuwien.ac.at [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria)

    2016-09-01

    Transient effects during erosion of polycrystalline tungsten-nitride (WN) films by mono-energetic deuterium projectiles are studied using a quartz crystal microbalance technique. The evolution of the mass removal rate of a 360 nm thin WN film under 500 eV/D and 1000 eV/D bombardment is investigated at a temperature of 465 K in situ and in real-time as a function of the deuterium fluence. The measurements are performed at a typical flux of 10{sup 18} m{sup −2} s{sup −1}. A strong dependency of the observed mass change rate on the deuterium fluence is found. The mass loss is initially higher than for pure tungsten (W) and drops with fluence, finally reaching the same steady state value as for pure W sputtering. Steady state surface conditions are obtained at a fluence of about 0.2 × 10{sup 23} D/m{sup 2} for 500 eV/D and 0.6 × 10{sup 23} D/m{sup 2} for 1000 eV/D. SDTrimSP simulations indicate a preferential removal of N and a corresponding W enrichment of the surface.

  4. Transient ischemic attack presenting in an elderly patient with transient ophthalmic manifestations

    Directory of Open Access Journals (Sweden)

    Sparshi Jain

    2016-01-01

    Full Text Available Transient ischemic attack (TIA is a transient neurological deficit of cerebrovascular origin without infarction which may last only for a short period and can have varying presentations. We report a case of 58-year-old male with presenting features of sudden onset transient vertical diplopia and transient rotatory nystagmus which self-resolved within 12 h. Patient had no history of any systemic illness. On investigating, hematological investigations and neuroimaging could not explain these sudden and transient findings. A TIA could possibly explain these sudden and transient ocular findings in our patient. This case report aims to highlight the importance of TIA for ophthalmologists. We must not ignore these findings as these could be warning signs of an impending stroke which may or may not be detected on neuroimaging. Thus, early recognition, primary prevention strategies, and timely intervention are needed.

  5. Computational scheme for transient temperature distribution in PWR vessel wall

    International Nuclear Information System (INIS)

    Dedovic, S.; Ristic, P.

    1980-01-01

    Computer code TEMPNES is a part of joint effort made in Gosa Industries in achieving the technique for structural analysis of heavy pressure vessels. Transient heat conduction problems analysis is based on finite element discretization of structures non-linear transient matrix formulation and time integration scheme as developed by Wilson (step-by-step procedure). Convection boundary conditions and the effect of heat generation due to radioactive radiation are both considered. The computation of transient temperature distributions in reactor vessel wall when the water temperature suddenly drops as a consequence of reactor cooling pump failure is presented. The vessel is treated as as axisymmetric body of revolution. The program has two finite time element options a) fixed predetermined increment and; b) an automatically optimized time increment for each step dependent on the rate of change of the nodal temperatures. (author)

  6. Experiments and simulation of high current operation at CEBAF

    International Nuclear Information System (INIS)

    Merminga, L.; Crawford, K.; Delayen, J.R.; Doolittle, L.; Hovater, C.; Kazimi, R.; Krafft, G.; Reece, C.; Simrock, S.; Tiefenback, M.; Wang, D.X.

    1996-01-01

    The superconducting rf, cw electron accelerator at CEBAF has achieved the design energy of 4 GeV using 5-pass recirculation through a pair of 400 MeV linacs. Stable beam current of 35 μA has been delivered to the Experimental Hall C. The total beam current that has been recirculated so far is 248 μA. Measurements of the performance of the rf control system have been made in both pulsed and cw mode, and a numerical model has been developed which describes the beam-cavity interaction, includes a realistic representation of low level controls, klystron characteristics and microphonic noise. Experimental data and simulation results on transient beam loading, klystron saturation, a new technique for cavity phasing, and heavy beam loading tests are described; in conclusion, an outlook on full current operation is presented

  7. A new circuit technique for reduced leakage current in Deep Submicron CMOS technologies

    Directory of Open Access Journals (Sweden)

    A. Schmitz

    2005-01-01

    Full Text Available Modern CMOS processes in the Deep Submicron regime are restricted to supply voltages below 2 volts and further to account for the transistors' field strength limitations and to reduce the power per logic gate. To maintain the high switching performance, the threshold voltage must be scaled according with the supply voltage. However, this leads to an increased subthreshold current of the transistors in standby mode (VGS=0. Another source of leakage is gate current, which becomes significant for gate oxides of 3nm and below. We propose a Self-Biasing Virtual Rails (SBVR - CMOS technique which acts like an adaptive local supply voltage in case of standby mode. Most important sources of leakage currents are reduced by this technique. Moreover, SBVR-CMOS is capable of conserving stored information in sleep mode, which is vital for memory circuits. Memories are exposed to radiation causing soft errors. This well-known problem becomes even worse in standby mode of typical SRAMs, that have low driving performance to withstand alpha particle hits. In this paper, a 16-transistor SRAM cell is proposed, which combines the advantage of extremely low leakage currents with a very high soft error stability.

  8. Proton current measurements using the prompt gamma ray diagnostic technique

    International Nuclear Information System (INIS)

    Leeper, R.J.; Burns, E.J.T.; Johnson, D.J.; McMurtry, W.M.

    1981-01-01

    Prompt gamma ray signals from the nuclear reaction 7 Li(p,γ) 8 Be have been used to make time resolved proton current measurements. In these measurements, the proton beam was allowed to strike cylindrical thick lithium metal targets. The time integrated proton current was measured using gamma activation of copper via the reaction 63 Cu(γ,n) 62 Cu(β+). The positron activity of the copper sample was easily measured using coincidence counting techniques. The number of 62 Cu atoms produced per proton incident on a thick Li metal target was determined with separate calibration runs performed on the Sandia 2.5 MeV Van de Graaff accelerator. The time history of the prompt gamma production was measured using six EGG NPM-54 scintillator photomultiplier combinations shielded by 96.5 cm of concrete and 5.1 cm of Pb. The use of six scintillator photomultiplier combinations was necessary to increase the statistical precision of the data. The normalization of the prompt gamma time history data with the total time integrated proton-current measurement yielded the absolute time resolved proton current on target. Data from runs performed on the Sandia Proto I accelerator will be presented

  9. Transient magnetic tunneling mediated by a molecular bridge

    Czech Academy of Sciences Publication Activity Database

    Kalvová, Anděla; Špička, Václav; Velický, B.

    2015-01-01

    Roč. 28, č. 3 (2015), 1087-1091 ISSN 1557-1939 R&D Projects: GA ČR GAP204/12/0897 Institutional support: RVO:68378271 Keywords : non-equilibrium * initial conditions * transient currents * molecular islands Subject RIV: BE - Theoretical Physics Impact factor: 1.100, year: 2015

  10. Tutorial: Junction spectroscopy techniques and deep-level defects in semiconductors

    Science.gov (United States)

    Peaker, A. R.; Markevich, V. P.; Coutinho, J.

    2018-04-01

    The term junction spectroscopy embraces a wide range of techniques used to explore the properties of semiconductor materials and semiconductor devices. In this tutorial review, we describe the most widely used junction spectroscopy approaches for characterizing deep-level defects in semiconductors and present some of the early work on which the principles of today's methodology are based. We outline ab-initio calculations of defect properties and give examples of how density functional theory in conjunction with formation energy and marker methods can be used to guide the interpretation of experimental results. We review recombination, generation, and trapping of charge carriers associated with defects. We consider thermally driven emission and capture and describe the techniques of Deep Level Transient Spectroscopy (DLTS), high resolution Laplace DLTS, admittance spectroscopy, and scanning DLTS. For the study of minority carrier related processes and wide gap materials, we consider Minority Carrier Transient Spectroscopy (MCTS), Optical DLTS, and deep level optical transient spectroscopy together with some of their many variants. Capacitance, current, and conductance measurements enable carrier exchange processes associated with the defects to be detected. We explain how these methods are used in order to understand the behaviour of point defects and the determination of charge states and negative-U (Hubbard correlation energy) behaviour. We provide, or reference, examples from a wide range of materials including Si, SiGe, GaAs, GaP, GaN, InGaN, InAlN, and ZnO.

  11. Scanning ion deep level transient spectroscopy: II. Ion irradiated Au-Si Schottky junctions

    International Nuclear Information System (INIS)

    Laird, J S; Jagadish, C; Jamieson, D N; Legge, G J F

    2006-01-01

    Here we introduce a new technique called scanning ion deep level transient spectroscopy (SIDLTS) for the spatial analysis of electrically active defects in devices. In the first part of this paper, a simple theory behind SIDLTS was introduced and factors determining its sensitivity and resolution were discussed. In this paper, we demonstrate the technique on MeV boron implantation induced defects in an Au-Si Schottky junction. SIDLTS measurements are compared with capacitance DLTS measurements over the temperature range, 100-300 K. SIDLTS analyses indicate the presence of two levels, one of which was positively identified as the E c - 0.23 eV divacancy level. The high sensitivity of SIDLTS is verified and the advantages and limitations of the technique are discussed in light of non-exponential components in the charge transient response. Reasons for several undetected levels are also discussed

  12. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  13. Theory of strong-field attosecond transient absorption

    International Nuclear Information System (INIS)

    Wu, Mengxi; Chen, Shaohao; Camp, Seth; Schafer, Kenneth J; Gaarde, Mette B

    2016-01-01

    Attosecond transient absorption is one of the promising new techniques being developed to exploit the availability of sub-femtosecond extreme ultraviolet (XUV) pulses to study the dynamics of the electron on its natural time scale. The temporal resolution in a transient absorption setup comes from the control of the relative delay and coherence between pump and probe pulses, while the spectral resolution comes from the characteristic width of the features that are being probed. In this review we focus on transient absorption scenarios where an attosecond pulse of XUV radiation creates a broadband excitation that is subsequently probed by a few cycle infrared (IR) laser. Because the attosecond XUV pulses are locked to the IR field cycle, the exchange of energy in the laser–matter interaction can be studied with unprecedented precision. We focus on the transient absorption by helium atoms of XUV radiation around the first ionization threshold, where we can simultaneoulsy solve the time-dependent Schrödinger equation for the single atom response and the Maxwell wave equation for the collective response of the nonlinear medium. We use a time-domain method that allows us to treat on an equal footing all the different linear and nonlinear processes by which the medium can exchange energy with the fields. We present several simple models, based on a few-level system interacting with a strong IR field, to explain many of the novel features found in attosecond transient absorption spectrograms. These include the presence of light-induced states, which demonstrate the ability to probe the dressed states of the atom. We also present a time-domain interpretation of the resonant pulse propagation features that appear in absorption spectra in dense, macroscopic media. We close by reviewing several recent experimental results that can be explained in terms of the models we discuss. Our aim is to present a road map for understanding future attosecond transient absorption

  14. Structure and dynamics of paramagnetic transients by pulsed EPR and NMR detection of nuclear resonance

    International Nuclear Information System (INIS)

    Trifunac, A.D.

    1981-01-01

    Structure and dynamics of transient radicals in pulse radiolysis can be studied by time resolved EPR and NMR techniques. EPR study of kinetics and relaxation is illustrated. The NMR detection of nuclear resonance in transient radicals is a new method which allows the study of hyperfine coupling, population dynamics, radical kinetics, and reaction mechanism. 9 figures

  15. Modelling of an ULOF transient in a sodium fast reactor

    International Nuclear Information System (INIS)

    Droin, Jean-Baptiste

    2016-01-01

    Within the framework of the Generation IV Sodium-cooled Fast Reactor (SFR) R and D program of CEA (French Commissariat a l'Energie Atomique et aux Energies Alternatives), safety in case of severe accidents is assessed.Such transients are usually simulated with mechanistic codes (such as SAS-SFR and SIMMER III). as a complement to these codes, which give reference accidental transient calculations, a new physico-statistical approach is currently followed by the CEA; its final objective being to derive the variability of the main results of interest for safety. This approach involves a fast-running description of extended accident sequences coupling physical models for the main phenomena to advanced statistical analysis techniques. It enables to perform a large number of simulations in a reasonable computational time and to describe all the possible bifurcations of the accident transient.In this context, this PhD work presents the physical tool (models and results assessment) dedicated to the initiation and primary phases of an Unprotected Loss Of Flow accident (i.e. until the end of sub-assemblies degradation and before large molten pools formation). The accident phenomenology during these phases is described and illustrated by numerous experimental evidences.It is underlined that the features of the new heterogeneous core concept (called CFV of the French ASTRID prototype) leads to different kinds of ULOF transients than those occurring in the previous past homogeneous cores (SuperPhenix, Phenix...). Indeed, its negative void effect drops the nuclear power when sodium heats-up and possibly boils. This enables three types of ULOF transients characterized by various core final states; the first two types leading to final coolable core states in natural circulation flow (the first one in single phase, the second one in stabilized two-phase flow) whereas the core undergoes a flow excursion followed by sub-assemblies degradation in the last type. In this study, a

  16. Predictive Modeling of Transient Storage and Nutrient Uptake: Implications for Stream Restoration

    Energy Technology Data Exchange (ETDEWEB)

    O’Connor, Ben L.; Hondzo, Miki; Harvey, Judson W.

    2010-12-01

    This study examined two key aspects of reactive transport modeling for stream restoration purposes: the accuracy of the nutrient spiraling and transient storage models for quantifying reach-scale nutrient uptake, and the ability to quantify transport parameters using measurements and scaling techniques in order to improve upon traditional conservative tracer fitting methods. Nitrate (NO-3)(NO3-) uptake rates inferred using the nutrient spiraling model underestimated the total NO-3NO3- mass loss by 82%, which was attributed to the exclusion of dispersion and transient storage. The transient storage model was more accurate with respect to the NO-3NO3- mass loss (±20%) and also demonstrated that uptake in the main channel was more significant than in storage zones. Conservative tracer fitting was unable to produce transport parameter estimates for a riffle-pool transition of the study reach, while forward modeling of solute transport using measured/scaled transport parameters matched conservative tracer breakthrough curves for all reaches. Additionally, solute exchange between the main channel and embayment surface storage zones was quantified using first-order theory. These results demonstrate that it is vital to account for transient storage in quantifying nutrient uptake, and the continued development of measurement/scaling techniques is needed for reactive transport modeling of streams with complex hydraulic and geomorphic conditions.

  17. Transients of Water Distribution and Transport in PEM Fuel Cells

    KAUST Repository

    Hussaini, Irfan S.; Wang, Chao-Yang

    2009-01-01

    The response of polymer electrolyte membrane (PEM) fuel cells to a step change in load is investigated experimentally in this work. Voltage undershoot, a characteristic feature of transient response following a step increase in current, is due to transients of water distribution in the membrane and ionomers occurring at subsecond time scales. The use of humidified reactants as a means to control the magnitude of voltage undershoot is demonstrated. Further, the response under a step decrease in current density is explored to determine the existence of hysteresis. Under sufficiently humidified conditions, the responses under forward and reverse step changes are symmetric, but under low relative humidity conditions, voltage undershoot is twice as large as the overshoot. © 2009 The Electrochemical Society.

  18. High energy transients: The millisecond domain

    Science.gov (United States)

    Rao, A. R.

    2018-02-01

    The search for high energy transients in the millisecond domain has come to the focus in recent times due to the detection of gravitational wave events and the identification of fast radio bursts as cosmological sources. Here we highlight the sensitivity limitations in the currently operating hard X-ray telescopes and give some details of the search for millisecond events in the AstroSat CZT Imager data.

  19. RETRAN operational transient analysis of the Big Rock Point plant boiling water reactor

    International Nuclear Information System (INIS)

    Sawtelle, G.R.; Atchison, J.D.; Farman, R.F.; VandeWalle, D.J.; Bazydlo, H.G.

    1983-01-01

    Energy Incorporated used the RETRAN computer code to model and calculate nine Consumers Power Company Big Rock Point Nuclear Power Plant transients. RETRAN, a best-estimate, one-dimensional, homogeneous-flow thermal-equilibrium code, is applicable to FSAR Chapter 15 transients for Conditions 1 through IV. The BWR analyses were performed in accordance with USNRC Standard Review Plan criteria and in response to the USNRC Systematic Evaluation Program. The RETRAN Big Rock Point model was verified by comparison to plant startup test data. This paper discusses the unique modeling techniques used in RETRAN to model this steam-drum-type BWR. Transient analyses results are also presented

  20. Simulation and analysis of transient over voltages due to capacitor banks switching

    International Nuclear Information System (INIS)

    Jadid, Sh.; Yazdanpanah, D.

    2002-01-01

    The switching of any capacitor bank produces over voltages. Transient overvoltage will always occur in the switching device, the switching of shunt capacitor bank has become the most common source of transient voltage on power systems. Transient over voltages due to switching the capacitor bands hurt not only to the capacitor banks, but also to other equipment, such as circuit breakers and transformers. Several methods are available for reducing energising transients. These devices include pre-insertion resistors, pre-insertion inductors,synchronous closing, and MOV arresters. However, not all are practical or economical. The other important problem is existence of capacitor banks in presence of harmonics.Capacitors do not produce harmonics;however,the addition of capacitors to the electrical system will change the frequency response characteristics of the system will change the frequency response characteristics of the system, and in some cases can result in magnification of the voltage and current distortion in the system. In other word in presence of harmonic-producing loads,the capacitors used for power factor correction,may cause parallel resonance with the system inductance, so they increase the total harmonic distortion of voltage and current waveforms

  1. Transient drainage summary report

    International Nuclear Information System (INIS)

    1996-09-01

    This report summarizes the history of transient drainage issues on the Uranium Mill Tailings Remedial Action (UMTRA) Project. It defines and describes the UMTRA Project disposal cell transient drainage process and chronicles UMTRA Project treatment of the transient drainage phenomenon. Section 4.0 includes a conceptual cross section of each UMTRA Project disposal site and summarizes design and construction information, the ground water protection strategy, and the potential for transient drainage

  2. The transient outward current in mice lacking the potassium channel gene Kv1.4

    Science.gov (United States)

    London, Barry; Wang, Dao W; Hill, Joseph A; Bennett, Paul B

    1998-01-01

    The transient outward current (Ito) plays a prominent role in the repolarization phase of the cardiac action potential. Several K+ channel genes, including Kv1.4, are expressed in the heart, produce rapidly inactivating currents when heterologously expressed, and may be the molecular basis of Ito.We engineered mice homozygous for a targeted disruption of the K+ channel gene Kv1.4 and compared Ito in wild-type (Kv1.4+/+), heterozygous (Kv1.4+/-) and homozygous ‘knockout’ (Kv1.4−/−) mice. Kv1.4 RNA was truncated in Kv1.4−/− mice and protein expression was absent.Adult myocytes isolated from Kv1.4+/+, Kv1.4+/− and Kv1.4−/− mice had large rapidly inactivating outward currents. The peak current densities at 60 mV (normalized by cellular capacitance, in pA pF−1; means ± s.e.m.) were 53.8 ± 5.3, 45.3 ± 2.2 and 44.4 ± 2.8 in cells from Kv1.4+/+, Kv1.4+/− and Kv1.4−/− mice, respectively (P mice.The voltage dependence and time course of inactivation were not changed by targeted disruption of Kv1.4. The mean best-fitting V½ (membrane potential at 50 % inactivation) values for myocytes from Kv1.4 +/+, Kv1.4+/− and Kv1.4−/− mice were -53.5 ± 3.7, -51.1 ± 2.6 and -54.2 ± 2.4 mV, respectively. The slope factors (k) were -10.1 ± 1.4, -8.8 ± 1.4 and -9.5 ± 1.2 mV, respectively. The fast time constants for development of inactivation at -30 mV were 27.8 ± 2.2, 26.2 ± 5.1 and 19.6 ± 2.1 ms in Kv1.4+/+, Kv1.4+/− and Kv1.4−/− myocytes, respectively. At +30 mV, they were 35.5 ± 2.6, 30.0 ± 2.1 and 28.7 ± 1.6 ms, respectively. The time constants for the rapid phase of recovery from inactivation at -80 mV were 32.5 ± 8.2, 23.3 ± 1.8 and 39.0 ± 3.7 ms, respectively.Nearly the entire inactivating component as well as more than 60 % of the steady-state outward current was eliminated by 1 mm 4-aminopyridine in Kv1.4+/+, Kv1.4+/− and Kv1.4−/− myocytes.Western blot analysis of heart membrane extracts showed no significant

  3. TRANSIENT ELECTRONICS CATEGORIZATION

    Science.gov (United States)

    2017-08-24

    AFRL-RY-WP-TR-2017-0169 TRANSIENT ELECTRONICS CATEGORIZATION Dr. Burhan Bayraktaroglu Devices for Sensing Branch Aerospace Components & Subsystems...SUBTITLE TRANSIENT ELECTRONICS CATEGORIZATION 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER N/A 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S) Dr. Burhan...88ABW-2017-3747, Clearance Date 31 July 2017. Paper contains color. 14. ABSTRACT Transient electronics is an emerging technology area that lacks proper

  4. A Sensorless Predictive Current Controlled Boost Converter by Using an EKF with Load Variation Effect Elimination Function.

    Science.gov (United States)

    Tong, Qiaoling; Chen, Chen; Zhang, Qiao; Zou, Xuecheng

    2015-04-28

    To realize accurate current control for a boost converter, a precise measurement of the inductor current is required to achieve high resolution current regulating. Current sensors are widely used to measure the inductor current. However, the current sensors and their processing circuits significantly contribute extra hardware cost, delay and noise to the system. They can also harm the system reliability. Therefore, current sensorless control techniques can bring cost effective and reliable solutions for various boost converter applications. According to the derived accurate model, which contains a number of parasitics, the boost converter is a nonlinear system. An Extended Kalman Filter (EKF) is proposed for inductor current estimation and output voltage filtering. With this approach, the system can have the same advantages as sensored current control mode. To implement EKF, the load value is necessary. However, the load may vary from time to time. This can lead to errors of current estimation and filtered output voltage. To solve this issue, a load variation elimination effect elimination (LVEE) module is added. In addition, a predictive average current controller is used to regulate the current. Compared with conventional voltage controlled system, the transient response is greatly improved since it only takes two switching cycles for the current to reach its reference. Finally, experimental results are presented to verify the stable operation and output tracking capability for large-signal transients of the proposed algorithm.

  5. Experimental study on transient boiling heat transfer

    International Nuclear Information System (INIS)

    Visentini, R.

    2012-01-01

    Boiling phenomena can be found in the everyday life, thus a lot of studies are devoted to them, especially in steady state conditions. Transient boiling is less known but still interesting as it is involved in the nuclear safety prevention. In this context, the present work was supported by the French Institute of Nuclear Safety (IRSN). In fact, the IRSN wanted to clarify what happens during a Reactivity-initiated Accident (RIA). This accident occurs when the bars that control the nuclear reactions break down and a high power peak is passed from the nuclear fuel bar to the surrounding fluid. The temperature of the nuclear fuel bar wall increases and the fluid vaporises instantaneously. Previous studies on a fuel bar or on a metal tube heated by Joule effect were done in the past in order to understand the rapid boiling phenomena during a RIA. However, the measurements were not really accurate because the measurement techniques were not able to follow rapid phenomena. The main goal of this work was to create an experimental facility able to simulate the RIA boiling conditions but at small scale in order to better understand the boiling characteristics when the heated-wall temperature increases rapidly. Moreover, the experimental set-up was meant to be able to produce less-rapid transients as well, in order to give information on transient boiling in general. The facility was built at the Fluid-Mechanics Institute of Toulouse. The core consists of a metal half-cylinder heated by Joule effect, placed in a half-annulus section. The inner half cylinder is made of a 50 microns thick stainless steel foil. Its diameter is 8 mm, and its length 200 mm. The outer part is a 34 mm internal diameter glass half cylinder. The semi-annular section is filled with a coolant, named HFE7000. The configuration allows to work in similarity conditions. The heated part can be place inside a loop in order to study the flow effect. The fluid temperature influence is taken into account as

  6. A novel application of wavelet based SVM to transient phenomena identification of power transformers

    International Nuclear Information System (INIS)

    Jazebi, S.; Vahidi, B.; Jannati, M.

    2011-01-01

    A novel differential protection approach is introduced in the present paper. The proposed scheme is a combination of Support Vector Machine (SVM) and wavelet transform theories. Two common transients such as magnetizing inrush current and internal fault are considered. A new wavelet feature is extracted which reduces the computational cost and enhances the discrimination accuracy of SVM. Particle swarm optimization technique (PSO) has been applied to tune SVM parameters. The suitable performance of this method is demonstrated by simulation of different faults and switching conditions on a power transformer in PSCAD/EMTDC software. The method has the advantages of high accuracy and low computational burden (less than a quarter of a cycle). The other advantage is that the method is not dependent on a specific threshold. Sympathetic and recovery inrush currents also have been simulated and investigated. Results show that the proposed method could remain stable even in noisy environments.

  7. Taipower's transient analysis methodology for pressurized water reactors

    International Nuclear Information System (INIS)

    Huang, Pinghue

    1998-01-01

    The methodology presented in this paper is a part of the 'Taipower's Reload Design and Transient Analysis Methodologies for Light Water Reactors' developed by the Taiwan Power Company (TPC) and the Institute of Nuclear Energy Research. This methodology utilizes four computer codes developed or sponsored by Electric Power Research institute: system transient analysis code RETRAN-02, core thermal-hydraulic analysis code COBRAIIIC, three-dimensional spatial kinetics code ARROTTA, and fuel rod evaluation code FREY. Each of the computer codes was extensively validated. Analysis methods and modeling techniques were conservatively established for each application using a systematic evaluation with the assistance of sensitivity studies. The qualification results and analysis methods were documented in detail in TPC topical reports. The topical reports for COBRAIIIC, ARROTTA. and FREY have been reviewed and approved by the Atomic Energy Council (ABC). TPC 's in-house transient methodology have been successfully applied to provide valuable support for many operational issues and plant improvements for TPC's Maanshan Units I and 2. Major applications include the removal of the resistance temperature detector bypass system, the relaxation of the hot-full-power moderator temperature coefficient design criteria imposed by the ROCAEC due to a concern on Anticipated Transient Without Scram, the reduction of boron injection tank concentration and the elimination of the heat tracing, and the reduction of' reactor coolant system flow. (author)

  8. Transient two-phase performance of LOFT reactor coolant pumps

    International Nuclear Information System (INIS)

    Chen, T.H.; Modro, S.M.

    1983-01-01

    Performance characteristics of Loss-of-Fluid Test (LOFT) reactor coolant pumps under transient two-phase flow conditions were obtained based on the analysis of two large and small break loss-of-coolant experiments conducted at the LOFT facility. Emphasis is placed on the evaluation of the transient two-phase flow effects on the LOFT reactor coolant pump performance during the first quadrant operation. The measured pump characteristics are presented as functions of pump void fraction which was determined based on the measured density. The calculated pump characteristics such as pump head, torque (or hydraulic torque), and efficiency are also determined as functions of pump void fractions. The importance of accurate modeling of the reactor coolant pump performance under two-phase conditions is addressed. The analytical pump model, currently used in most reactor analysis codes to predict transient two-phase pump behavior, is assessed

  9. On the estimation of the current density in space plasmas: Multi- versus single-point techniques

    Science.gov (United States)

    Perri, Silvia; Valentini, Francesco; Sorriso-Valvo, Luca; Reda, Antonio; Malara, Francesco

    2017-06-01

    Thanks to multi-spacecraft mission, it has recently been possible to directly estimate the current density in space plasmas, by using magnetic field time series from four satellites flying in a quasi perfect tetrahedron configuration. The technique developed, commonly called ;curlometer; permits a good estimation of the current density when the magnetic field time series vary linearly in space. This approximation is generally valid for small spacecraft separation. The recent space missions Cluster and Magnetospheric Multiscale (MMS) have provided high resolution measurements with inter-spacecraft separation up to 100 km and 10 km, respectively. The former scale corresponds to the proton gyroradius/ion skin depth in ;typical; solar wind conditions, while the latter to sub-proton scale. However, some works have highlighted an underestimation of the current density via the curlometer technique with respect to the current computed directly from the velocity distribution functions, measured at sub-proton scales resolution with MMS. In this paper we explore the limit of the curlometer technique studying synthetic data sets associated to a cluster of four artificial satellites allowed to fly in a static turbulent field, spanning a wide range of relative separation. This study tries to address the relative importance of measuring plasma moments at very high resolution from a single spacecraft with respect to the multi-spacecraft missions in the current density evaluation.

  10. Transient heat loads in current fusion experiments, extrapolation to ITER and consequences for its operation

    International Nuclear Information System (INIS)

    Loarte, A; Saibene, G; Sartori, R; Riccardo, V; Andrew, P; Paley, J; Fundamenski, W; Eich, T; Herrmann, A; Pautasso, G; Kirk, A; Counsell, G; Federici, G; Strohmayer, G; Whyte, D; Leonard, A; Pitts, R A; Landman, I; Bazylev, B; Pestchanyi, S

    2007-01-01

    New experimental results on transient loads during ELMs and disruptions in present divertor tokamaks are described and used to carry out a extrapolation to ITER reference conditions and to draw consequences for its operation. In particular, the achievement of low energy/convective type I edge localized modes (ELMs) in ITER-like plasma conditions seems the only way to obtain transient loads which may be compatible with an acceptable erosion lifetime of plasma facing components (PFCs) in ITER. Power loads during disruptions, on the contrary, seem to lead in most cases to an acceptable divertor lifetime because of the relatively small plasma thermal energy remaining at the thermal quench and the large broadening of the power flux footprint during this phase. These conclusions are reinforced by calculations of the expected erosion lifetime, under these load conditions, which take into account a realistic temporal dependence of the power fluxes on PFCs during ELMs and disruptions

  11. Variable thickness transient ground-water flow model. Volume 1. Formulation

    International Nuclear Information System (INIS)

    Reisenauer, A.E.

    1979-12-01

    Mathematical formulation for the variable thickness transient (VTT) model of an aquifer system is presented. The basic assumptions are described. Specific data requirements for the physical parameters are discussed. The boundary definitions and solution techniques of the numerical formulation of the system of equations are presented

  12. Investigate Transient Behaviours and Select Appropriate Fault Protection Solutions of Uni-grounded AC Microgrids

    Directory of Open Access Journals (Sweden)

    Duong Minh Bui

    2016-03-01

    Full Text Available Transient situations of a uni-grounded low-voltage AC microgrid are simulated in this paper, which include different fault tests and operation transition test between the grid-connected and islanded modes of the uni-grounded microgrid. Based on transient simulation results, available fault protection methods are proposed for the main and back-up protection of a uni-grounded AC microgrid. Main contributions of this paper are (i analysing transient responses of a typically uni-grounded lowvoltage AC microgrid from line-to-line, single line-to-ground, three-phase faults and a microgrid operation transition test; and (ii proposing available fault protection methods for uni-grounded AC microgrids, such as non-directional/directional overcurrent protection solutions, under/over voltage protection solutions, differential protection, voltage-restrained overcurrent protection, and other protection principles not based on high fault currents (e.g. total harmonic distortion detection of phase currents and voltages, or protection methods using symmetrical sequence components of current and voltage.

  13. Response of dairy cattle to transient voltages and magnetic fields

    International Nuclear Information System (INIS)

    Reinemann, D.J.; Laughlin, N.K.; Stetson, L.E.

    1995-01-01

    Stray voltages in dairy facilities have been studied since the 1970's. Previous research using steady-state ac and dc voltages has defined cow-contact voltage levels which may cause behavior and associated production problems. This research was designed to address concerns over possible effects of transient voltages and magnetic fields on dairy cows. Dairy cows response to transient voltages and magnetic fields was measured. The waveforms of the transient voltages applied were: 5 cycles of 60-Hz ac with a total pulse time of 83 ms, 1 cycle of 60-Hz ac with a total pulse time of 16 ms, and 1 cycle of an ac square wave (spiking positive and negative) of 2-ms duration. Alternating magnetic fields were produced by passing 60-Hz ac fundamental frequency with 2nd and 3rd harmonic and random noise components in metal structures around the cows. The maximum magnetic field associated with this current flow was in excess of 4 G. A wide range of sensitivity to transient voltages was observed among cows. Response levels from 24 cows to each transient exposure were normally distributed. No responses to magnetic fields were observed

  14. Admittance spectroscopy or deep level transient spectroscopy: A contrasting juxtaposition

    Science.gov (United States)

    Bollmann, Joachim; Venter, Andre

    2018-04-01

    A comprehensive understanding of defects in semiconductors remains of primary importance. In this paper the effectiveness of two of the most commonly used semiconductor defect spectroscopy techniques, viz. deep level transient spectroscopy (DLTS) and admittance spectroscopy (AS) are reviewed. The analysis of defects present in commercially available SiC diodes shows that admittance spectroscopy allows the identification of deep traps with reduced measurement effort compared to deep Level Transient Spectroscopy (DLTS). Besides the N-donor, well-studied intrinsic defects were detected in these diodes. Determination of their activation energy and defect density, using the two techniques, confirm that the sensitivity of AS is comparable to that of DLTS while, due to its well defined peak shape, the spectroscopic resolution is superior. Additionally, admittance spectroscopy can analyze faster emission processes which make the study of shallow defects more practical and even that of shallow dopant levels, possible. A comparative summary for the relevant spectroscopic features of the two capacitance methods are presented.

  15. Fluid transient analysis and design considerations in TVA PWR feedwater systems and steam generators

    International Nuclear Information System (INIS)

    Kelley, B.T.

    1979-01-01

    TVA has evaluated a number of fluid transients in an effort to discover areas of potential problems and to improve overall unit operation. The transients recently or currently being evaluated fall into four major areas - accident analyses, fast valving, heater drain systems, and steam generators. A discussion of each area follows

  16. Effects of transient conditions on exhaust emissions from two non-road diesel engines

    International Nuclear Information System (INIS)

    Lindgren, M.; Hansson, P.-A.

    2004-01-01

    Growing interest in quantifying and reducing the amount of engine emissions of carbon monoxide, hydrocarbons, and nitrogen oxides loading the environment has led to increasingly tighter environmental regulations. However, current non-road emission standards are performed according to a steady-state test cycle, which does not include transient effects and thus underestimates the amount of emissions produced in real use of the engine. This study quantifies the effects of transients in engine speed and torque on the fuel consumption and emissions from two diesel engines intended for non-road mobile machinery. Fuel consumption and emissions from the engines were measured in an engine dynamometer during various transient load conditions. The results showed that during fast transients, the measured fuel consumption was up to twice as high as the corresponding steady-state load conditions. The effects of transients on emissions of nitrogen oxides were even greater, as were the effects of transient load increase with increasing transient conditions i. e. rate of change. The results showed that the effect of transients on fuel consumption and emissions were also dependent on the type of diesel injection pump and the engine equipment used. Furthermore, the results indicated that the air/fuel ratio was an important contributor to the emission formation process during transient loads. (Author)

  17. Technology for Transient Simulation of Vibration during Combustion Process in Rocket Thruster

    Science.gov (United States)

    Zubanov, V. M.; Stepanov, D. V.; Shabliy, L. S.

    2018-01-01

    The article describes the technology for simulation of transient combustion processes in the rocket thruster for determination of vibration frequency occurs during combustion. The engine operates on gaseous propellant: oxygen and hydrogen. Combustion simulation was performed using the ANSYS CFX software. Three reaction mechanisms for the stationary mode were considered and described in detail. The way for obtaining quick CFD-results with intermediate combustion components using an EDM model was found. The way to generate the Flamelet library with CFX-RIF was described. A technique for modeling transient combustion processes in the rocket thruster was proposed based on the Flamelet library. A cyclic irregularity of the temperature field like vortex core precession was detected in the chamber. Frequency of flame precession was obtained with the proposed simulation technique.

  18. Detection and Sizing of Fatigue Cracks in Steel Welds with Advanced Eddy Current Techniques

    Science.gov (United States)

    Todorov, E. I.; Mohr, W. C.; Lozev, M. G.

    2008-02-01

    Butt-welded specimens were fatigued to produce cracks in the weld heat-affected zone. Advanced eddy current (AEC) techniques were used to detect and size the cracks through a coating. AEC results were compared with magnetic particle and phased-array ultrasonic techniques. Validation through destructive crack measurements was also conducted. Factors such as geometry, surface treatment, and crack tightness interfered with depth sizing. AEC inspection techniques have the potential of providing more accurate and complete sizing flaw data for manufacturing and in-service inspections.

  19. Nanosecond UV lasers stimulate transient Ca2+ elevations in human hNT astrocytes.

    Science.gov (United States)

    Raos, B J; Graham, E S; Unsworth, C P

    2017-06-01

    Astrocytes respond to various stimuli resulting in intracellular Ca 2+ signals that can propagate through organized functional networks. Recent literature calls for the development of techniques that can stimulate astrocytes in a fast and highly localized manner to emulate more closely the characteristics of astrocytic Ca 2+ signals in vivo. In this article we demonstrate, for the first time, how nanosecond UV lasers are capable of reproducibly stimulating Ca 2+ transients in human hNT astrocytes. We report that laser pulses with a beam energy of 4-29 µJ generate transient increases in cytosolic Ca 2+ . These Ca 2+ transients then propagate to adjacent astrocytes as intercellular Ca 2+ waves. We propose that nanosecond laser stimulation provides a valuable tool for enabling the study of Ca 2+ dynamics in human astrocytes at both a single cell and network level. Compared to previously developed techniques nanosecond laser stimulation has the advantage of not requiring loading of photo-caged or -sensitising agents, is non-contact, enables stimulation with a high spatiotemporal resolution and is comparatively cost effective.

  20. Transient Infrared Emission Spectroscopy

    Science.gov (United States)

    Jones, Roger W.; McClelland, John F.

    1989-12-01

    Transient Infrared Emission Spectroscopy (TIRES) is a new technique that reduces the occurrence of self-absorption in optically thick solid samples so that analytically useful emission spectra may be observed. Conventional emission spectroscopy, in which the sample is held at an elevated, uniform temperature, is practical only for optically thin samples. In thick samples the emission from deep layers of the material is partially absorbed by overlying layers.1 This self-absorption results in emission spectra from most optically thick samples that closely resemble black-body spectra. The characteristic discrete emission bands are severely truncated and altered in shape. TIRES bypasses this difficulty by using a laser to heat only an optically thin surface layer. The increased temperature of the layer is transient since the layer will rapidly cool and thicken by thermal diffusion; hence the emission collection must be correlated with the laser heating. TIRES may be done with both pulsed and cw lasers.2,3 When a pulsed laser is used, the spectrometer sampling must be synchronized with the laser pulsing so that only emission during and immediately after each laser pulse is observed.3 If a cw laser is used, the sample must move rapidly through the beam. The hot, transient layer is then in the beam track on the sample at and immediately behind the beam position, so the spectrometer field of view must be limited to this region near the beam position.2 How much self-absorption the observed emission suffers depends on how thick the heated layer has grown by thermal diffusion when the spectrometer samples the emission. Use of a pulsed laser synchronized with the spectrometer sampling readily permits reduction of the time available for heat diffusion to about 100 acs .3 When a cw laser is used, the heat-diffusion time is controlled by how small the spectrometer field of view is and by how rapidly the sample moves past within this field. Both a very small field of view and a

  1. Compositional Abstraction of PEPA Models for Transient Analysis

    DEFF Research Database (Denmark)

    Smith, Michael James Andrew

    2010-01-01

    - or interval - Markov chains allow us to aggregate states in such a way as to safely bound transient probabilities of the original Markov chain. Whilst we can apply this technique directly to a PEPA model, it requires us to obtain the CTMC of the model, whose state space may be too large to construct......Stochastic process algebras such as PEPA allow complex stochastic models to be described in a compositional way, but this leads to state space explosion problems. To combat this, there has been a great deal of work in developing techniques for abstracting Markov chains. In particular, abstract...

  2. Controlling the Er content of porous silicon using the doping current intensity

    KAUST Repository

    Mula, Guido; Loddo, Lucy; Pinna, Elisa; Tiddia, Maria V; Mascia, Michele; Palmas, Simonetta; Ruffilli, Roberta; Falqui, Andrea

    2014-01-01

    measurements were used to investigate on the transient during the first stages of constant current Er doping. Depending on the applied current intensity, the voltage transient displays two very different behaviors, signature of two different chemical processes

  3. Improvement of the transient stability using SFCL in Korean power systems

    International Nuclear Information System (INIS)

    Hwang, Intae; Lee, Seung Ryul; Seo, Sangsoo; Yoon, Jaeyoung; Kim, Chul-Hwan

    2013-01-01

    Highlights: •In Korea, the Special Protection System is applied for protecting the power system. •Hybrid SFCL is protecting the power system from viewpoint of the transient stability. •Basic hybrid SFCL system cannot recover during the auto-reclosing operation. •This paper performs analysis of transient stability using the novel hybrid SFCL. -- Abstract: This paper proposed a novel hybrid SFCL system for the enhancement of the transient stability in Korean power transmission system with auto-reclosing operation. The proposed SFCL system has an operation mechanism that the current limiting impedance is eliminated from the power system in a fault clearing time for the enhancement of the transient stability. Also, the system can cover the auto-reclosing operation of the transmission power system. This study analyzed an improvement of the special protection system by applying the proposed SFCL system to real power system in Korea

  4. Could the cosmic acceleration be transient?

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Antonio C.C.; Lima, J.A.S. [Universidade de Sao Paulo (IAG/USP), SP (Brazil). Inst. de Astronomia, Geofisica e Ciencias Atmosfericas

    2011-07-01

    Full text: The possibility of a transient cosmic acceleration appears in several theoretical scenarios and is theoretically interesting because it solves some difficulties inherent to eternally accelerating universes (like {Lambda}CDM). On the observational side, some authors, using a dynamical Ansatz for the dark energy equation of state, have suggested that the cosmic acceleration have already peaked and that we are currently witnessing its slowing down. Here, a possible slowing down of the cosmic expansion is investigated through a cosmographic approach. By expanding the luminous distance to fourth order and fitting the SNe Ia data from the most recent compilations (Union, Constitution and Union 2), the marginal likelihood distribution for the deceleration parameter today indicates that there is a considerable probability for q{sub 0} > 0. Also in contrast to the prediction of the {Lambda}CDM model, the cosmographic q(z) reconstruction suggests that the cosmic acceleration could already have peaked and be presently slowing down, what would imply that the recent accelerated expansion of the Universe is a transient phenomenon. It is also shown that to describe a transient acceleration the luminous distance needs to be expanded at least to fourth order. The present cosmographic results depend neither on the validity of general relativity nor on the matter-energy contents of the Universe. (author)

  5. Beam induced rf cavity transient voltage

    International Nuclear Information System (INIS)

    Kramer, S.L.; Wang, J.M.

    1998-10-01

    The authors calculate the transient voltage induced in a radio frequency cavity by the injection of a relativistic bunched beam into a circular accelerator. A simplified model of the beam induced voltage, using a single tone current signal, is generated and compared with the voltage induced by a more realistic model of a point-like bunched beam. The high Q limit of the bunched beam model is shown to be related simply to the simplified model. Both models are shown to induce voltages at the resonant frequency ω r of the cavity and at an integer multiple of the bunch revolution frequency (i.e. the accelerating frequency for powered cavity operation) hω ο . The presence of two nearby frequencies in the cavity leads to a modulation of the carrier wave exp(hω ο t). A special emphasis is placed in this paper on studying the modulation function. These models prove useful for computing the transient voltage induced in superconducting rf cavities, which was the motivation behind this research. The modulation of the transient cavity voltage discussed in this paper is the physical basis of the recently observed and explained new kinds of longitudinal rigid dipole mode which differs from the conventional Robinson mode

  6. Waves of visibility: probing the depth of inter-ocular suppression with transient and sustained targets

    Directory of Open Access Journals (Sweden)

    Lisandro eKaunitz

    2014-07-01

    Full Text Available In order to study non-conscious visual processing, researchers render otherwise consciously perceived images into invisible stimuli. Through the years, several psychophysical techniques have been developed for this purpose. Yet the comparison of experimental results across techniques remains a difficult task as the depth of suppression depends on the interactions between the type of stimuli and the suppression methods employed. This poses a limit to the inferences that researchers make about the extent of non-conscious processes. We investigated the mechanisms underlying inter-ocular suppression during continuous flash suppression (CFS and dichoptic visual masking using a transient onset target stimulus and a variety of stimulus / mask temporal manipulations. We show that target duration, timing of target onset, and mask frequency are key aspects of inter-ocular suppression during CFS with transient targets. The differences between our results and sustained target CFS studies suggest that two distinct mechanisms are involved in the detection of transient and prolonged target stimuli during CFS. Our results provide insight into the dynamics of CFS together with evidence for similarities between transient target CFS and dichoptic visual masking.

  7. Heavy Ion Microbeam and Broadbeam Transients in SiGe HBTs

    Science.gov (United States)

    Pellish, Jonathan A.; Reed, Robert A.; McMorrow, Dale; Vizkelethy, Gyorgy; Dodd, Paul E.; Ferlet-Cavrois, Veronique; Baggio, Jacques; Paillet, Philippe; Duhamel, Olivier; Phillips, Stanley D.; hide

    2009-01-01

    SiGe HBT heavy ion current transients are measured using microbeam and both high- and low-energy broadbeam sources. These new data provide detailed insight into the effects of ion range, LET, and strike location.

  8. Steady state and transient power handling in JET

    International Nuclear Information System (INIS)

    Matthews, G.F.

    2003-01-01

    Steady state and transient power deposition profiles have been measured in the JET MIIGB divertor using improved diagnostics techniques involving the use of fast infra-red, thermocouples and Langmuir probe arrays. In unfuelled type I ELMy H-modes a very narrow power profile is observed at the outer target which we associate with the ion channel. Systematic parameter scans have been carried out and our analysis shows that the average power width scaling is consistent with a classical dependence of perpendicular transport in the SOL. Using the fast IR capability the factors such as rise time, broadening, variability and in/out asymmetry have been studied and lead to the conclusion that type I ELMs in ITER may fall just below the material ablation limits. JET disruptions are very different from type I ELMs in that only a small fraction of the thermal energy reaches the divertor and what does arrive is distributed uniformly over the divertor area. This is very different from the current ITER assumption which puts most of the energy from the thermal quench onto the divertor strike points. (author)

  9. Transient behavior of interface state continuum at InP insulator-semiconductor interface

    International Nuclear Information System (INIS)

    Hasegawa, H.; Masuda, H.; He, L.; Luo, J.K.; Sawada, T.; Ohno, H.

    1987-01-01

    To clarify the drain current drift mechanism in InP MISFETs, an isothermal capacitance transient spectroscopy (ICTS) study of the interface state continuum is made on the anodic Al 2 O 3 /native oxide/ InP MIS system. Capture behavior is temperature-independent, non-exponential and extremely slow, whereas emission behavior is temperature- and bias- dependent, and is much faster. The observed behavior is explained quantitatively by the disorder induced gap state (DIGS) model, where states are distributed both in energy and in space. By comparing the transient behavior of interface states with the observed drift behavior of MISFETs, it is concluded that the electron capture by the DIGS continuum is responsible for the drain current drift of MISFETs. This led to a complete computer simulation of the observed current drift behavior

  10. Transient analysis on the SMART-P anticipated transients without scram

    International Nuclear Information System (INIS)

    Yang, S. H.; Bae, K. H.; Kim, H. C.; Zee, S. Q.

    2005-01-01

    Anticipated transients without scram (ATWS) are anticipated operational occurrences accompanied by a failure of an automatic reactor trip when required. Although the occurrence probability of the ATWS events is considerably low, these events can result in unacceptable consequences, i.e. the pressurization of the reactor coolant system (RCS) up to an unacceptable range and a core-melting situation. Therefore, the regulatory body requests the installation of a protection system against the ATWS events. According to the request, a diverse protection system (DPS) is installed in the SMART-P (System-integrated Modular Advanced ReacTor-Pilot). This paper presents the results of the transient analysis performed to identify the performance of the SMART-P against the ATWS. In the analysis, the TASS/SMR (Transients And Setpoint Simulation/Small and Medium Reactor) code is applied to identify the thermal hydraulic response of the RCS during the transients

  11. Discrete oscillator design linear, nonlinear, transient, and noise domains

    CERN Document Server

    Rhea, Randall W

    2014-01-01

    Oscillators are an essential part of all spread spectrum, RF, and wireless systems, and today's engineers in the field need to have a firm grasp on how they are designed. Presenting an easy-to-understand, unified view of the subject, this authoritative resource covers the practical design of high-frequency oscillators with lumped, distributed, dielectric and piezoelectric resonators. Including numerous examples, the book details important linear, nonlinear harmonic balance, transient and noise analysis techniques. Moreover, the book shows you how to apply these techniques to a wide range of os

  12. STUDY OF TRANSIENT AND STATIONARY OPERATION MODES OF SYNCHRONOUS SYSTEM CONSISTING IN TWO MACHINES

    Directory of Open Access Journals (Sweden)

    V. S. Safaryan

    2017-01-01

    Full Text Available The solution of the problem of reliable functioning of an electric power system (EPS in steady-state and transient regimes, prevention of EPS transition into asynchronous regime, maintenance and restoration of stability of post-emergency processes is based on formation and realization of mathematical models of an EPS processes. During the functioning of electric power system in asynchronous regime, besides the main frequencies, the currents and voltages include harmonic components, the frequencies of which are multiple of the difference of main frequencies. At the two-frequency asynchronous regime the electric power system is being made equivalent in a form of a two-machine system, functioning for a generalized load. In the article mathematical models of transient process of a two-machine system in natural form and in d–q coordinate system are presented. The mathematical model of two-machine system is considered in case of two windings of excitement at the rotors. Also, in the article varieties of mathematical models of EPS transient regimes (trivial, simple, complete are presented. Transient process of a synchronous two-machine system is described by the complete model. The quality of transient processes of a synchronous machine depends on the number of rotor excitation windings. When there are two excitation windings on the rotor (dual system of excitation, the mathematical model of electromagnetic transient processes of a synchronous machine is represented in a complex form, i.e. in coordinate system d, q, the current of rotor being represented by a generalized vector. In asynchronous operation of a synchronous two-machine system with two excitation windings on the rotor the current and voltage systems include only harmonics of two frequencies. The mathematical model of synchronous steady-state process of a two-machine system is also provided, and the steady-state regimes with different structures of initial information are considered.

  13. Application of an eddy current technique to steam generator U-bend characterization. Final report

    International Nuclear Information System (INIS)

    Cramer, W.E.; de la Pintiere, L.; Narita, S.; Bergander, M.J.

    1982-04-01

    Eddy current nondestructive testing techniques are used widely throughout the utility industry for the early detection of tube damage in critical power plant components such as steam generators. In this project, the application of an eddy current technique for the characterization of U-bend transitions in the first row tubing in Westinghouse 51 Series Steam Generators has been investigated. A method has been developed for detection of the opposite transition in the U-bend and for defining its severity. Investigation included two different types of U-bend transitions. Using the developed eddy current method for U-bend characterization, on-site inspection was performed on all tubes in the first row in four 51 Series steam generators in Power Plant Unit No. 2 and in one 51 Series steam generator in Power Plant Unit No. 1. The advantages and limitations of the developed method as well as the recommendations for further investigations are included

  14. Transient accelerating scalar models with exponential potentials

    International Nuclear Information System (INIS)

    Cui Wen-Ping; Zhang Yang; Fu Zheng-Wen

    2013-01-01

    We study a known class of scalar dark energy models in which the potential has an exponential term and the current accelerating era is transient. We find that, although a decelerating era will return in the future, when extrapolating the model back to earlier stages (z ≳ 4), scalar dark energy becomes dominant over matter. So these models do not have the desired tracking behavior, and the predicted transient period of acceleration cannot be adopted into the standard scenario of the Big Bang cosmology. When couplings between the scalar field and matter are introduced, the models still have the same problem; only the time when deceleration returns will be varied. To achieve re-deceleration, one has to turn to alternative models that are consistent with the standard Big Bang scenario.

  15. FIRST RESULTS FROM THE CATALINA REAL-TIME TRANSIENT SURVEY

    International Nuclear Information System (INIS)

    Drake, A. J.; Djorgovski, S. G.; Mahabal, A.; Graham, M. J.; Williams, R.; Beshore, E.; Larson, S.; Boattini, A.; Gibbs, A.; Hill, R.; Kowalski, R.; Christensen, E.; Catelan, M.

    2009-01-01

    We report on the results from the first six months of the Catalina Real-Time Transient Survey (CRTS). In order to search for optical transients (OTs) with timescales of minutes to years, the CRTS analyses data from the Catalina Sky Survey which repeatedly covers 26,000 of square degrees on the sky. The CRTS provides a public stream of transients that are bright enough to be followed up using small telescopes. Since the beginning of the survey, all CRTS transients have been made available to astronomers around the world in real time using HTML tables,RSS feeds, and VOEvents. As part of our public outreach program, the detections are now also available in Keyhole Markup Language through Google Sky. The initial discoveries include over 350 unique OTs rising more than 2 mag from past measurements. Sixty two of these are classified as supernovae (SNe), based on light curves, prior deep imaging and spectroscopic data. Seventy seven are due to cataclysmic variables (CVs; only 13 previously known), while an additional 100 transients were too infrequently sampled to distinguish between faint CVs and SNe. The remaining OTs include active galactic nucleus, blazars, high-proper-motions stars, highly variable stars (such as UV Ceti stars), and transients of an unknown nature. Our results suggest that there is a large population of SNe missed by many current SN surveys because of selection biases. These objects appear to be associated with faint host galaxies. We also discuss the unexpected discovery of white dwarf binary systems through dramatic eclipses.

  16. Image reconstruction with an adaptive threshold technique in electrical resistance tomography

    International Nuclear Information System (INIS)

    Kim, Bong Seok; Khambampati, Anil Kumar; Kim, Sin; Kim, Kyung Youn

    2011-01-01

    In electrical resistance tomography, electrical currents are injected through the electrodes placed on the surface of a domain and the corresponding voltages are measured. Based on these currents and voltage data, the cross-sectional resistivity distribution is reconstructed. Electrical resistance tomography shows high temporal resolution for monitoring fast transient processes, but it still remains a challenging problem to improve the spatial resolution of the reconstructed images. In this paper, a novel image reconstruction technique is proposed to improve the spatial resolution by employing an adaptive threshold method to the iterative Gauss–Newton method. Numerical simulations and phantom experiments have been performed to illustrate the superior performance of the proposed scheme in the sense of spatial resolution

  17. Transient thermal stresses of work roll by coupled thermoelasticity

    Science.gov (United States)

    Lai, W. B.; Chen, T. C.; Weng, C. I.

    1991-01-01

    A numerical method, based on a two-dimensional plane strain model, is developed to predict the transient responses (that include distributions of temperature, thermal deformation, and thermal stress) of work roll during strip rolling by coupled thermoelasticity. The method consists of discretizing the space domain of the problem by finite element method first, and then treating the time domain by implicit time integration techniques. In order to avoid the difficulty in analysis due to relative movement between work roll and its thermal boundary, the energy equation is formulated with respect to a fixed Eulerian reference frame. The effect of thermoelastic coupling term, that is generally disregarded in strip rolling, can be considered and assessed. The influences of some important process parameters, such as rotational speed of the roll and intensity of heat flux, on transient solutions are also included and discussed. Furthermore, since the stress history at any point of the roll in both transient and steady state could be accurately evaluated, it is available to perform the analysis of thermal fatigue for the roll by means of previous data.

  18. VLITE-Fast: A Real-time, 350 MHz Commensal VLA Survey for Fast Transients

    Science.gov (United States)

    Kerr, Matthew; Ray, Paul S.; Kassim, Namir E.; Clarke, Tracy; Deneva, Julia; Polisensky, Emil

    2018-01-01

    The VLITE (VLA Low Band Ionosphere and Transient Experiment; http://vlite.nrao.edu) program operates commensally during all Very Large Array observations, collecting data from 320 to 384 MHz. Recently expanded to include 16 antennas, the large field of view and huge time on sky offer good coverage of the transient, low-frequency sky. We describe the VLITE-Fast system, a GPU-based signal processor capable of detecting short (system, techniques for mitigating interference, and initial results from searches for FRBs.

  19. Advanced analysis technique for the evaluation of linear alternators and linear motors

    Science.gov (United States)

    Holliday, Jeffrey C.

    1995-01-01

    A method for the mathematical analysis of linear alternator and linear motor devices and designs is described, and an example of its use is included. The technique seeks to surpass other methods of analysis by including more rigorous treatment of phenomena normally omitted or coarsely approximated such as eddy braking, non-linear material properties, and power losses generated within structures surrounding the device. The technique is broadly applicable to linear alternators and linear motors involving iron yoke structures and moving permanent magnets. The technique involves the application of Amperian current equivalents to the modeling of the moving permanent magnet components within a finite element formulation. The resulting steady state and transient mode field solutions can simultaneously account for the moving and static field sources within and around the device.

  20. Transient flow combustion

    Science.gov (United States)

    Tacina, R. R.

    1984-01-01

    Non-steady combustion problems can result from engine sources such as accelerations, decelerations, nozzle adjustments, augmentor ignition, and air perturbations into and out of the compressor. Also non-steady combustion can be generated internally from combustion instability or self-induced oscillations. A premixed-prevaporized combustor would be particularly sensitive to flow transients because of its susceptability to flashback-autoignition and blowout. An experimental program, the Transient Flow Combustion Study is in progress to study the effects of air and fuel flow transients on a premixed-prevaporized combustor. Preliminary tests performed at an inlet air temperature of 600 K, a reference velocity of 30 m/s, and a pressure of 700 kPa. The airflow was reduced to 1/3 of its original value in a 40 ms ramp before flashback occurred. Ramping the airflow up has shown that blowout is more sensitive than flashback to flow transients. Blowout occurred with a 25 percent increase in airflow (at a constant fuel-air ratio) in a 20 ms ramp. Combustion resonance was found at some conditions and may be important in determining the effects of flow transients.

  1. Transcranial direct current stimulation as a treatment for auditory hallucinations.

    Directory of Open Access Journals (Sweden)

    Sanne eKoops

    2015-03-01

    Full Text Available Auditory hallucinations (AH are a symptom of several psychiatric disorders, such as schizophrenia. In a significant minority of patients, AH are resistant to antipsychotic medication. Alternative treatment options for this medication-resistant group are scarce and most of them focus on coping with the hallucinations. Finding an alternative treatment that can diminish AH is of great importance.Transcranial direct current stimulation (tDCS is a safe and non-invasive technique that is able to directly influence cortical excitability through the application of very low electric currents. A 1-2 mA direct current is applied between two surface electrodes, one serving as the anode and the other as the cathode. Cortical excitability is increased in the vicinity of the anode and reduced near the cathode. The technique, which has only a few transient side effects and is cheap and portable, is increasingly explored as a treatment for neurological and psychiatric symptoms. It has shown efficacy on symptoms of depression, bipolar disorder, schizophrenia, Alzheimer’s disease, Parkinson’s disease, epilepsy and stroke. However, the application of tDCS as a treatment for AH is relatively new. This article provides an overview of the current knowledge in this field and provides guidelines for future research.

  2. An intensity-monitoring technique for measuring ellipsometric transients

    NARCIS (Netherlands)

    Droog, J.M.M.; Bootsma, G.A.

    1979-01-01

    Intensity-monitoring techniques make possible the measurement of rapid changes in the ellipsometric parameters. Methods used hitherto have been suitable for measuring slight changes only and require prior knowledge of the Δ and Ψ values for the initial surface. It is shown that larger changes can

  3. Defect States in InP/InGaAs/InP Heterostructures by Current-Voltage Characteristics and Deep Level Transient Spectroscopy.

    Science.gov (United States)

    Vu, Thi Kim Oanh; Lee, Kyoung Su; Lee, Sang Jun; Kim, Eun Kyu

    2018-09-01

    We studied defect states in In0.53Ga0.47As/InP heterojunctions with interface control by group V atoms during metalorganic chemical vapor (MOCVD) deposition. From deep level transient spectroscopy (DLTS) measurements, two defects with activation energies of 0.28 eV (E1) and 0.15 eV (E2) below the conduction band edge, were observed. The defect density of E1 for In0.53Ga0.47As/InP heterojunctions with an addition of As and P atoms was about 1.5 times higher than that of the heterojunction added P atom only. From the temperature dependence of current- voltage characteristics, the thermal activation energies of In0.53Ga0.47As/InP of heterojunctions were estimated to be 0.27 and 0.25 eV, respectively. It appeared that the reverse light current for In0.53Ga0.47As/InP heterojunction added P atom increased only by illumination of a 940 nm-LED light source. These results imply that only the P addition at the interface can enhance the quality of InGaAs/InP heterojunction.

  4. On tridimensional rip current modeling

    Science.gov (United States)

    Marchesiello, Patrick; Benshila, Rachid; Almar, Rafael; Uchiyama, Yusuke; McWilliams, James C.; Shchepetkin, Alexander

    2015-12-01

    Do lateral shear instabilities of nearshore circulation account for a substantial part of Very Low-Frequency (VLF) variability? If yes, it would promote stirring and mixing of coastal waters and surf-shelf exchanges. Another question is whether tridimensional transient processes are important for instability generation. An innovative modeling system with tridimensional wave-current interactions was designed to investigate transient nearshore currents and interactions between nearshore and innershelf circulations. We present here some validation of rip current modeling for the Aquitanian coast of France, using in-situ and remote video sensing. We then proceed to show the benefits of 3D versus 2D (depth-mean flow) modeling of rip currents and their low-frequency variability. It appears that a large part of VLF motions is due to intrinsic variability of the tridimensional flow. 3D models may thus provide a valuable, only marginally more expensive alternative to conventional 2D approaches that miss the vertical flow structure and its nonlinear interaction with the depth-averaged flow.

  5. Generation of intense transient magnetic fields

    International Nuclear Information System (INIS)

    Benjamin, R.F.

    1983-01-01

    In a laser system, the return current of a laser generated plasma is conducted near a target to subject that target to a magnetic field. The target may be either a small non-fusion object for testing under the magnetic field or a laser-fusion pellet. In the laser-fusion embodiment, the laser-fusion pellet is irradiated during the return current flow and the intense transient magnetic field is used to control the hot electrons thereof to hinder them from striking and heating the core of the irradiated laser-fusion pellet. An emitter, e.g. a microballoon of glass, metal or plastics, is subjected to a laser pulse to generate the plasma from which the return current flows into a wire cage or a coil and then to earth. (author)

  6. Space Vector Modulation Technique to Reduce Leakage Current of a Transformerless Three-Phase Four-Leg Photovoltaic System

    Directory of Open Access Journals (Sweden)

    F. Hasanzad

    2017-06-01

    Full Text Available Photovoltaic systems integrated to the grid have received considerable attention around the world. They can be connected to the electrical grid via galvanic isolation (transformer or without it (transformerless. Despite making galvanic isolation, low frequency transformer increases size, cost and losses. On the other hand, transformerless PV systems increase the leakage current (common-mode current, (CMC through the parasitic capacitors of the PV array. Inverter topology and switching technique are the most important parameters the leakage current depends on. As there is no need to extra hardware for switching scheme modification, it's an economical method for reducing leakage current. This paper evaluates the effect of different space vector modulation techniques on leakage current for a two-level three-phase four-leg inverter used in PV system. It proposes an efficient space vector modulation method which decreases the leakage current to below the quantity specified in VDE-0126-1-1 standard. furthermore, some other characteristics of the space vector modulation schemes that have not been significantly discussed for four-leg inverter, are considered, such as, modulation index, switching actions per period, common-mode voltage (CMV, and total harmonic distortion (THD. An extend software simulation using MATLAB/Simulink is performed to verify the effectiveness of the modulation technique.

  7. The detection of transient directional couplings based on phase synchronization

    International Nuclear Information System (INIS)

    Wagner, T; Fell, J; Lehnertz, K

    2010-01-01

    We extend recent approaches based on the concept of phase synchronization to enable the time-resolved investigation of directional relationships between coupled dynamical systems from short and transient noisy time series. For our approach, we consider an observed ensemble of a sufficiently large number of time series as multiple realizations of a process. We derive an index that quantifies the direction of transient interactions and assess its statistical significance using surrogate techniques. Analysing time series from noisy and chaotic systems, we demonstrate numerically the applicability and limitations of our approach. Our findings from an exemplary application to event-related brain activities underline the importance of our method for improving knowledge about the mechanisms underlying memory formation in humans.

  8. The detection of transient directional couplings based on phase synchronization

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, T; Fell, J; Lehnertz, K, E-mail: twagner@uni-bonn.d [Department of Epileptology, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany)

    2010-05-15

    We extend recent approaches based on the concept of phase synchronization to enable the time-resolved investigation of directional relationships between coupled dynamical systems from short and transient noisy time series. For our approach, we consider an observed ensemble of a sufficiently large number of time series as multiple realizations of a process. We derive an index that quantifies the direction of transient interactions and assess its statistical significance using surrogate techniques. Analysing time series from noisy and chaotic systems, we demonstrate numerically the applicability and limitations of our approach. Our findings from an exemplary application to event-related brain activities underline the importance of our method for improving knowledge about the mechanisms underlying memory formation in humans.

  9. Some new directions in system transient simulation

    International Nuclear Information System (INIS)

    Ransom, V.H.

    1986-01-01

    The current research in system transient simulation at the Idaho National Engineering Laboratory (INEL) is summarized in this paper and three new directions that are emerging from this work are discussed. The new directions are: development of an Advanced Thermal Hydraulic Energy Network Analyzer (ATHENA) having new modeling capability, use of expert systems for enhancing simulation methods, and the trend to individual workstations for simulation

  10. Cernavoda unit2 recirculated cooling water system transient analysis

    International Nuclear Information System (INIS)

    Nita, I. P.; Pancef, R.

    2015-01-01

    The paper is an approach to calculate the response of Cernavoda NPP Unit 2 RCW System to transient regimes during normal and abnormal regimes. Then one started to analyse the system response to reactor trip on class III and IV of power, LOCA on class IV of power, LOCA on class III power, LOIA on class IV of power, and LOIA on class III power. Moreover, one analysed the system transient due to requirement of changeover of a RCW operating pump, planned and unplanned changeover. This is the first transient approach to this system that took in consideration all building of the system, obtaining a very large system model, with over 900 pipe, 4 pumps, 50 consumers, 21 control valves. The changeover procedure was required to be analysed in order to change the nominal operating mode for Unit 2, from current 2 pumps in operation to 3 pump operations during summer operating mode. (authors)

  11. Susceptibility and hardening of electronic systems to fast transient threats: new challenges ahead

    Directory of Open Access Journals (Sweden)

    F. Sabath

    2004-01-01

    Full Text Available The field of susceptibility and hardening of electronic systems to transient threats has experienced a significant growth during the past ten years. Driven by the development in the area of non-lethal electromagnetic weapons it has become necessary to extend the classical set of transient threats, consisting of LEMP, ESD and NEMP, by a fast transient threat with an extreme bandwidth. The investigation of the susceptibility to those UWB threats, characterized by a bandwidth of more than a quarter of the center frequency, rise times of less than 200 ps and pulse durations in the ns regime, is of special interest. This paper presents an overview of current challenges of the hardening against UWB threats. It discusses recent research trends in transient susceptibility measurements, protection concepts and methods of analysis.

  12. Glutathionylation-Dependence of Na+-K+-Pump Currents Can Mimic Reduced Subsarcolemmal Na+ Diffusion

    Science.gov (United States)

    Garcia, Alvaro; Liu, Chia-Chi; Cornelius, Flemming; Clarke, Ronald J.; Rasmussen, Helge H.

    2016-01-01

    The existence of a subsarcolemmal space with restricted diffusion for Na+ in cardiac myocytes has been inferred from a transient peak electrogenic Na+-K+ pump current beyond steady state on reexposure of myocytes to K+ after a period of exposure to K+-free extracellular solution. The transient peak current is attributed to enhanced electrogenic pumping of Na+ that accumulated in the diffusion-restricted space during pump inhibition in K+-free extracellular solution. However, there are no known physical barriers that account for such restricted Na+ diffusion, and we examined if changes of activity of the Na+-K+ pump itself cause the transient peak current. Reexposure to K+ reproduced a transient current beyond steady state in voltage-clamped ventricular myocytes as reported by others. Persistence of it when the Na+ concentration in patch pipette solutions perfusing the intracellular compartment was high and elimination of it with K+-free pipette solution could not be reconciled with restricted subsarcolemmal Na+ diffusion. The pattern of the transient current early after pump activation was dependent on transmembrane Na+- and K+ concentration gradients suggesting the currents were related to the conformational poise imposed on the pump. We examined if the currents might be accounted for by changes in glutathionylation of the β1 Na+-K+ pump subunit, a reversible oxidative modification that inhibits the pump. Susceptibility of the β1 subunit to glutathionylation depends on the conformational poise of the Na+-K+ pump, and glutathionylation with the pump stabilized in conformations equivalent to those expected to be imposed on voltage-clamped myocytes supported this hypothesis. So did elimination of the transient K+-induced peak Na+-K+ pump current when we included glutaredoxin 1 in patch pipette solutions to reverse glutathionylation. We conclude that transient K+-induced peak Na+-K+ pump current reflects the effect of conformation-dependent β1 pump subunit

  13. Glutathionylation-Dependence of Na(+)-K(+)-Pump Currents Can Mimic Reduced Subsarcolemmal Na(+) Diffusion.

    Science.gov (United States)

    Garcia, Alvaro; Liu, Chia-Chi; Cornelius, Flemming; Clarke, Ronald J; Rasmussen, Helge H

    2016-03-08

    The existence of a subsarcolemmal space with restricted diffusion for Na(+) in cardiac myocytes has been inferred from a transient peak electrogenic Na(+)-K(+) pump current beyond steady state on reexposure of myocytes to K(+) after a period of exposure to K(+)-free extracellular solution. The transient peak current is attributed to enhanced electrogenic pumping of Na(+) that accumulated in the diffusion-restricted space during pump inhibition in K(+)-free extracellular solution. However, there are no known physical barriers that account for such restricted Na(+) diffusion, and we examined if changes of activity of the Na(+)-K(+) pump itself cause the transient peak current. Reexposure to K(+) reproduced a transient current beyond steady state in voltage-clamped ventricular myocytes as reported by others. Persistence of it when the Na(+) concentration in patch pipette solutions perfusing the intracellular compartment was high and elimination of it with K(+)-free pipette solution could not be reconciled with restricted subsarcolemmal Na(+) diffusion. The pattern of the transient current early after pump activation was dependent on transmembrane Na(+)- and K(+) concentration gradients suggesting the currents were related to the conformational poise imposed on the pump. We examined if the currents might be accounted for by changes in glutathionylation of the β1 Na(+)-K(+) pump subunit, a reversible oxidative modification that inhibits the pump. Susceptibility of the β1 subunit to glutathionylation depends on the conformational poise of the Na(+)-K(+) pump, and glutathionylation with the pump stabilized in conformations equivalent to those expected to be imposed on voltage-clamped myocytes supported this hypothesis. So did elimination of the transient K(+)-induced peak Na(+)-K(+) pump current when we included glutaredoxin 1 in patch pipette solutions to reverse glutathionylation. We conclude that transient K(+)-induced peak Na(+)-K(+) pump current reflects the effect

  14. A comparison of two three-dimensional shell-element transient electromagnetics codes

    International Nuclear Information System (INIS)

    Yugo, J.J.; Williamson, D.E.

    1992-01-01

    Electromagnetic forces due to eddy currents strongly influence the design of components for the next generation of fusion devices. An effort has been made to benchmark two computer programs used to generate transient electromagnetic loads: SPARK and EddyCuFF. Two simple transient field problems were analyzed, both of which had been previously analyzed by the SPARK code with results recorded in the literature. A third problem that uses an ITER inboard blanket benchmark model was analyzed as well. This problem was driven with a self-consistent, distributed multifilament plasma model generated by an axisymmetric physics code. The benchmark problems showed good agreement between the two shell-element codes. Variations in calculated eddy currents of 1--3% have been found for similar, finely meshed models. A difference of 8% was found in induced current and 20% in force for a coarse mesh and complex, multifilament field driver. Because comparisons were made to results obtained from literature, model preparation and code execution times were not evaluated

  15. Current status of models for transient phenomena in dopant diffusion and activation

    International Nuclear Information System (INIS)

    Pichler, P.; Stiebel, D.

    2002-01-01

    Transient phenomena caused by ion-implantation processes have been studied for more than 25 years now with a continuously increasing number of research articles published in this field per year. One driving force of this research is the ongoing miniaturization of ULSI MOS and bipolar technology which uses extensively the capabilities of technology-computer-aided-design (TCAD). The other driving force which attracts also academic institutions and research institutes is the high complexity of the phenomena, involving the interaction of dopants, intrinsic point defects, extended defects and impurities like carbon as well as the interactions of mobile defects with surfaces and interfaces and their redistribution in multilayer structures. This paper outlines some recent advances towards a quantitative description of such phenomena

  16. ATHENA simulations of divertor pump trip and loss of heat sink transients for the GSSR

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeberg, A

    2001-04-01

    The ITER-FEAT Generic Site Safety Report includes evaluations of the consequences of various types of conceivable transients that may occur during operation. The transients that have to be considered in this respect are specified in the Accident Analysis Specifications document of the safety report. For the divertor primary heat transport system the ranges of transients include amongst others a trip of the main circulation pump in the divertor cooling loop as well as a loss of heat sink, both initiated at full fusion power operation. The thermal-hydraulic consequences related to the coolability of the divertor primary heat transport system components for these two transients have been evaluated and summarized in the safety report and in the current report an overview of those efforts and associated outcome is provided. The analyses have been made with the ATHENA thermal-hydraulic code using a separately developed ATHENA model of the ITER-FEAT divertor cooling system. The results from the analyses indicate that for the pump trip transient the margin against overheating of critical highly loaded parts of the divertor cassette is small but seems sufficient. In case of the loss of heat sink transient the conservative analysis reveals that the pressurizer safety valve will be opened for an extended period of time and the long term transient development indicates a risk of completely filling up the pressurizer vessel. Thus the margins against jeopardizing the integrity of the divertor cooling system with the current design are for this case small but can for a long term operation at associate conditions pose a problem.

  17. Transient gas flow through layered porous media

    International Nuclear Information System (INIS)

    Morrison, F.A. Jr.

    1975-01-01

    Low Reynolds number isothermal flow of an ideal gas through layered porous material was investigated analytically. Relations governing the transient flow in one dimension are obtained. An implicit, iterative, unconditionally stable finite difference scheme is developed for calculation of such flows. A computer code, SIROCCO, employing this technique has been written and implemented on the LLL computer system. A listing of the code is included. This code may be effectively applied to the evaluation of stemming plans for underground nuclear experiments. (U.S.)

  18. Reduced-order modellin for high-pressure transient flow of hydrogen-natural gas mixture

    Science.gov (United States)

    Agaie, Baba G.; Khan, Ilyas; Alshomrani, Ali Saleh; Alqahtani, Aisha M.

    2017-05-01

    In this paper the transient flow of hydrogen compressed-natural gas (HCNG) mixture which is also referred to as hydrogen-natural gas mixture in a pipeline is numerically computed using the reduced-order modelling technique. The study on transient conditions is important because the pipeline flows are normally in the unsteady state due to the sudden opening and closure of control valves, but most of the existing studies only analyse the flow in the steady-state conditions. The mathematical model consists in a set of non-linear conservation forms of partial differential equations. The objective of this paper is to improve the accuracy in the prediction of the HCNG transient flow parameters using the Reduced-Order Modelling (ROM). The ROM technique has been successfully used in single-gas and aerodynamic flow problems, the gas mixture has not been done using the ROM. The study is based on the velocity change created by the operation of the valves upstream and downstream the pipeline. Results on the flow characteristics, namely the pressure, density, celerity and mass flux are based on variations of the mixing ratio and valve reaction and actuation time; the ROM computational time cost advantage are also presented.

  19. Transient potentials in dendritic systems of arbitrary geometry.

    Science.gov (United States)

    Butz, E G; Cowan, J D

    1974-09-01

    A simple graphical calculus is developed that generates analytic solutions for membrane potential transforms at any point on the dendritic tree of neurons with arbitrary dendritic geometries, in response to synaptic "current" inputs. Such solutions permit the computation of transients in neurons with arbitrary geometry and may facilitate analysis of the role of dendrites in such cells.

  20. Signature of transient boundary layer processes observed with Viking

    International Nuclear Information System (INIS)

    Woch, J.; Lundin, R.

    1992-01-01

    Transient penetration of plasma with magnetosheath origin is frequently observed with the hot plasma experiment on board the Viking satellite at auroral latitudes in the dayside magnetosphere. The injected magnetosheath ions exhibit a characteristic pitch angle/energy dispersion pattern earlier reported for solar wind ions accessing the magnetosphere in the cusp regions. In contrast to the continuous plasma entry in the cusp, the events discussed here show temporal features which suggest a connection to transient processes at or in the vicinity of the magnetospheric boundary. A single event study confirms previously published observations that the injected ions flow essentially tailward with a velocity comparable to the magnetosheath flow and that the energy spectra inferred for the source population resemble magnetosheath spectra. Based on a statistical study, it is found that these events are predominantly observed around 0800 and 1600 MLT, in a region populated by both rung current/plasma sheet particles and by particles whose source is the magnetosheath plasma. Magnetic field line tracing based on the Tsyganenko magnetic field model yields a scatter of the source locations around the mid-latitude region of the magnetospheric boundary. The probability for these events to occur is highest when the interplanetary magnetic field (IMF) is confined to the ecliptic plane. The connection of the events to transient impulsive solar wind/magnetosphere interaction processes, such as transient reconnection (FTE), impulsive plasma transfer, Kelvin Helmholtz instabilities, and solar wind pressure pulses, is discussed. A relation with transient reconnection can be excluded

  1. A Novel Sliding Mode Control Technique for Indirect Current Controlled Active Power Filter

    Directory of Open Access Journals (Sweden)

    Juntao Fei

    2012-01-01

    Full Text Available A novel sliding mode control (SMC method for indirect current controlled three-phase parallel active power filter is presented in this paper. There are two designed closed loops in the system: one is the DC voltage controlling loop and the other is the reference current tracking loop. The first loop with a PI regulator is used to control the DC voltage approximating to the given voltage of capacitor, and the output of PI regulator through a low-pass filter is applied as the input of the power supply reference currents. The second loop implements the tracking of the reference currents using integral sliding mode controller, which can improve the harmonic treating performance. Compared with the direct current control technique, it is convenient to be implemented with digital signal processing system because of simpler system structure and better harmonic treating property. Simulation results verify that the generated reference currents have the same amplitude with the load currents, demonstrating the superior harmonic compensating effects with the proposed shunt active power filter compared with the hysteresis method.

  2. Transient-field strength measurements for 52Cr traversing Fe hosts at high velocity and polarization transfer mechanisms

    International Nuclear Information System (INIS)

    Stuchbery, A.E.; Doran, C.E.; Byrne, A.P.; Bolotin, H.H.; Dracoulis, G.D.

    1986-12-01

    Transient-field strengths were measured for 52 Cr ions traversing polarized Fe hosts at velocities up to 12v>=o (v>=o = c/137 = Bohr velocity). The results are compared with predictions of various transient field parametrizations and discussed in terms of possible mechanisms by which polarization might be transferred from the Fe host to inner vacancies of the moving Cr ions. The g-factor of the first 2 + state of 52 Cr was also measured by the transient field technique and found to be in accord with shell-model calculations

  3. Impact Assessment of Various Methods for Control of Synchronous Generator Excitation on Quality of Transient Processes

    Directory of Open Access Journals (Sweden)

    Y. D. Filipchik

    2011-01-01

    Full Text Available The paper considers an impact of various methods for control of an exciting current pertaining to a synchronous generator on the nature of transient processes. A control algorithm for the exciting current in relation to changes in sliding and acceleration of a generator rotor has been proposed in the paper. The algorithm makes it possible to improve quality of the transient processes due to reduction of oscillation range concerning as an active power so a δ-angle as well.

  4. Ultrafast Degenerate Transient Lens Spectroscopy in Semiconductor Nanosctructures

    Directory of Open Access Journals (Sweden)

    Leontyev A.V.

    2015-01-01

    Full Text Available We report the non-resonant excitation and probing of the nonlinear refractive index change in bulk semiconductors and semiconductor quantum dots through degenerate transient lens spectroscopy. The signal oscillates at the center laser field frequency, and the envelope of the former in quantum dots is distinctly different from the one in bulk sample. We discuss the applicability of this technique for polarization state probing in semiconductor media with femtosecond temporal resolution.

  5. Temporal frequency probing for 5D transient analysis of global light transport

    KAUST Repository

    O'Toole, Matthew; Heide, Felix; Xiao, Lei; Hullin, Matthias B.; Heidrich, Wolfgang; Kutulakos, Kiriakos N.

    2014-01-01

    To overcome this complexity, we observe that transient light transport is always separable in the temporal frequency domain. This makes it possible to analyze transient transport one temporal frequency at a time by trivially adapting techniques from conventional projector-to-camera transport. We use this idea in a prototype that offers three never-seen-before abilities: (1) acquiring time-of-flight depth images that are robust to general indirect transport, such as interreflections and caustics; (2) distinguishing between direct views of objects and their mirror reflection; and (3) using a photonic mixer device to capture sharp, evolving wavefronts of "light-in-flight".

  6. Fuel damage during off-normal transients in metal-fueled fast reactors

    International Nuclear Information System (INIS)

    Kramer, J.M.; Bauer, T.H.

    1990-01-01

    Fuel damage during off-normal transients is a key issue in the safety of fast reactors because the fuel pin cladding provides the primary barrier to the release of radioactive materials. Part of the Safety Task of the Integral Fast Reactor Program is to provide assessments of the damage and margins to failure for metallic fuels over the wide range of transients that must be considered in safety analyses. This paper reviews the current status of the analytical and experimental programs that are providing the bases for these assessments. 13 refs., 2 figs

  7. Modulation of the transient outward current (Ito) in rat cardiac myocytes and human Kv4.3 channels by mefloquine

    International Nuclear Information System (INIS)

    Perez-Cortes, E.J.; Islas, A.A.; Arevalo, J.P.; Mancilla, C.; Monjaraz, E.; Salinas-Stefanon, E.M.

    2015-01-01

    The antimalarial drug mefloquine, is known to be a potassium channel blocker, although its mechanism of action has not being elucidated and its effects on the transient outward current (I to ) and the molecular correlate, the K v 4.3 channel has not being studied. Here, we describe the mefloquine-induced inhibition of the rat ventricular I to and of CHO cells co-transfected with human K v 4.3 and its accessory subunit hKChIP2C by whole-cell voltage-clamp. Mefloquine inhibited rat I to and hK v 4.3 + KChIP2C currents in a concentration-dependent manner with a limited voltage dependence and similar potencies (IC 50 = 8.9 μM and 10.5 μM for cardiac myocytes and K v 4.3 channels, respectively). In addition, mefloquine did not affect the activation of either current but significantly modified the hK v 4.3 steady-state inactivation and recovery from inactivation. The effects of this drug was compared with that of 4-aminopyridine (4-AP), a well-known potassium channel blocker and its binding site does not seem to overlap with that of 4-AP. - Highlights: • Mefloquine inhibited ventricular I to and hK v 4.3 channels. IC 50 = 8.9 and 10.5 μM. • Inactivation and recovery from inactivation in the hK v 4.3 channels were modified by mefloquine. • Mefloquine displayed a higher affinity for the inactivated state. • The binding site for mefloquine may be located in the extracellular side of the channel.

  8. Mathematical Model and Computational Analysis of Selected Transient States of Cylindrical Linear Induction Motor Fed via Frequency Converter

    Directory of Open Access Journals (Sweden)

    Andrzej Rusek

    2008-01-01

    Full Text Available The mathematical model of cylindrical linear induction motor (C-LIM fed via frequency converter is presented in the paper. The model was developed in order to analyze numerically the transient states. Problems concerning dynamics of ac-machines especially linear induction motor are presented in [1 – 7]. Development of C-LIM mathematical model is based on circuit method and analogy to rotary induction motor. The analogy between both: (a stator and rotor windings of rotary induction motor and (b winding of primary part of C-LIM (inductor and closed current circuits in external secondary part of C-LIM (race is taken into consideration. The equations of C-LIM mathematical model are presented as matrix together with equations expressing each vector separately. A computational analysis of selected transient states of C-LIM fed via frequency converter is presented in the paper. Two typical examples of C-LIM operation are considered for the analysis: (a starting the motor at various static loads and various synchronous velocities and (b reverse of the motor at the same operation conditions. Results of simulation are presented as transient responses including transient electromagnetic force, transient linear velocity and transient phase current.

  9. Modeling transient radiation effects in power MOSFETS

    International Nuclear Information System (INIS)

    Hoffman, J.R.; Hall, W.E.; Dunn, D.E.

    1987-01-01

    Using standard device specifications and simple assumptions, the transient radiation response of VDMOS MOSFETs can be modeled in a standard circuit analysis program. The device model consists of a body diode, a parasitic bipolar transistor, and elements to simulate high-current reduced breakdown. The attached photocurrent model emulates response to any pulse shape and accounts for bias-dependent depletion regions. The model can be optimized to best fit available test data

  10. Transients: The regulator's view

    International Nuclear Information System (INIS)

    Sheron, B.W.; Speis, T.P.

    1984-01-01

    This chapter attempts to clarify the basis for the regulator's concerns for transient events. Transients are defined as both anticipated operational occurrences and postulated accidents. Recent operational experience, supplemented by improved probabilistic risk analysis methods, has demonstrated that non-LOCA transient events can be significant contributors to overall risk. Topics considered include lessons learned from events and issues, the regulations governing plant transients, multiple failures, different failure frequencies, operator errors, and public pressure. It is concluded that the formation of Owners Groups and Regulatory Response Groups within the owners groups are positive signs of the industry's concern for safety and responsible dealing with the issues affecting both the US NRC and the industry

  11. Focused cognitive control in dishonesty: Evidence for predominantly transient conflict adaptation.

    Science.gov (United States)

    Foerster, Anna; Pfister, Roland; Schmidts, Constantin; Dignath, David; Wirth, Robert; Kunde, Wilfried

    2018-04-01

    Giving a dishonest response to a question entails cognitive conflict due to an initial activation of the truthful response. Following conflict monitoring theory, dishonest responding could therefore elicit transient and sustained control adaptation processes to mitigate such conflict, and the current experiments take on the scope and specificity of such conflict adaptation in dishonesty. Transient adaptation reduces differences between honest and dishonest responding following a recent dishonest response. Sustained adaptation has a similar behavioral signature but is driven by the overall frequency of dishonest responding. Both types of adaptation to recent and frequent dishonest responses have been separately documented, leaving open whether control processes in dishonest responding can flexibly adapt to transient and sustained conflict signals of dishonest and other actions. This was the goal of the present experiments which studied (dis)honest responding to autobiographical yes/no questions. Experiment 1 showed robust transient adaptation to recent dishonest responses whereas sustained control adaptation failed to exert an influence on behavior. It further revealed that transient effects may create a spurious impression of sustained adaptation in typical experimental settings. Experiments 2 and 3 examined whether dishonest responding can profit from transient and sustained adaption processes triggered by other behavioral conflicts. This was clearly not the case: Dishonest responding adapted markedly to recent (dis)honest responses but not to any context of other conflicts. These findings indicate that control adaptation in dishonest responding is strong but surprisingly focused and they point to a potential trade-off between transient and sustained adaptation. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Lightning transient analysis in wind turbine blades

    DEFF Research Database (Denmark)

    Candela Garolera, Anna; Holbøll, Joachim; Madsen, Søren Find

    2013-01-01

    The transient behavior of lightning surges in the lightning protection system of wind turbine blades has been investigated in this paper. The study is based on PSCAD models consisting of electric equivalent circuits with lumped and distributed parameters involving different lightning current...... waveforms. The aim of the PSCAD simulations is to study the voltages induced by the lightning current in the blade that may cause internal arcing. With this purpose, the phenomenon of current reflections in the lightning down conductor of the blade and the electromagnetic coupling between the down conductor...... and other internal conductive elements of the blade is studied. Finally, several methods to prevent internal arcing are discussed in order to improve the lightning protection of the blade....

  13. Transient Mixed Convection Validation for NGNP

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Barton [Utah State Univ., Logan, UT (United States); Schultz, Richard [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-10-19

    The results of this project are best described by the papers and dissertations that resulted from the work. They are included in their entirety in this document. They are: (1) Jeff Harris PhD dissertation (focused mainly on forced convection); (2) Blake Lance PhD dissertation (focused mainly on mixed and transient convection). This dissertation is in multi-paper format and includes the article currently submitted and one to be submitted shortly; and, (3) JFE paper on CFD Validation Benchmark for Forced Convection.

  14. Transient Mixed Convection Validation for NGNP

    International Nuclear Information System (INIS)

    Smith, Barton; Schultz, Richard

    2015-01-01

    The results of this project are best described by the papers and dissertations that resulted from the work. They are included in their entirety in this document. They are: (1) Jeff Harris PhD dissertation (focused mainly on forced convection); (2) Blake Lance PhD dissertation (focused mainly on mixed and transient convection). This dissertation is in multi-paper format and includes the article currently submitted and one to be submitted shortly; and, (3) JFE paper on CFD Validation Benchmark for Forced Convection.

  15. Effect of State Feedback Coupling and System Delays on the Transient Performance of Stand-Alone VSI with LC Output Filter

    DEFF Research Database (Denmark)

    Federico, de Bosio; de Sousa Ribeiro, Luiz Antonio; Freijedo Fernandez, Francisco Daniel

    2016-01-01

    The influence of state feedback coupling in the dynamics performance of power converters for stand-alone microgrids is investigated. Computation and PWM delays are the main factors that limit the achievable bandwidth of current regulators in digital implementations. In particular, the performance...... of state feedback decoupling is degraded because of these delays. Two decoupling techniques to improve the transient response of the system are investigated, named non-ideal and ideal capacitor voltage decoupling respectively. In particular, the latter solution consists in leading the capacitor voltage...... on the state feedback decoupling path in order to compensate for system delays. Practical implementation issues are discussed with reference to both the decoupling techniques. A design methodology for the voltage loop, that considers the closed loop transfer functions developed for the inner loop, is also...

  16. Analytical solutions for thermal transient profile in solid target irradiated with low energy and high beam current protons

    International Nuclear Information System (INIS)

    Oliveira, Henrique B. de; Brazao, Nei G.; Sciani, Valdir

    2009-01-01

    There were obtained analytical solutions for thermal transient in solid targets, used in short half-life radioisotopes production, when irradiated with low energy and high beam current protons, in the cyclotron accelerator Cyclone 30 of the Institute for Energy and Nuclear Research (IPEN/CNEN-SP). The beam spatial profile was considered constant and the time depended heat distribution equation was resolved for a continuous particles flow entering the target. The problem was divided into two stages: a general solution was proposed which is the sum of two functions, the first one related to the thermal equilibrium situation and the second one related to a time dependent function that was determinate by the setting of the contour conditions and the initial conditions imposed by the real problem. By that one got an analytic function for a complete description of the heat transport phenomenon inside the targets. There were used both, numerical and symbolic computation methods, to obtain temperature maps and thermal gradients and the results showed an excellent agreement when compared with purely numerical models. The results were compared with obtained data from Gallium-67 and Thallium-201 irradiation routines conducted by the IPEN Cyclotrons accelerators center, showing excellent agreement. The objective of this paper is to develop solid targets irradiation systems (metals and oxides) so that one can operate with high levels of current beam, minimizing the irradiation time and maximizing the final returns. (author)

  17. Predicting core losses and efficiency of SRM in continuous current mode of operation using improved analytical technique

    International Nuclear Information System (INIS)

    Parsapour, Amir; Dehkordi, Behzad Mirzaeian; Moallem, Mehdi

    2015-01-01

    In applications in which the high torque per ampere at low speed and rated power at high speed are required, the continuous current method is the best solution. However, there is no report on calculating the core loss of SRM in continuous current mode of operation. Efficiency and iron loss calculation which are complex tasks in case of conventional mode of operation is even more involved in continuous current mode of operation. In this paper, the Switched Reluctance Motor (SRM) is modeled using finite element method and core loss and copper loss of SRM in discontinuous and continuous current modes of operation are calculated using improved analytical techniques to include the minor loop losses in continuous current mode of operation. Motor efficiency versus speed in both operation modes is obtained and compared. - Highlights: • Continuous current method for Switched Reluctance Motor (SRM) is explained. • An improved analytical technique is presented for SRM core loss calculation. • SRM losses in discontinuous and continuous current operation modes are presented. • Effect of mutual inductances on SRM performance is investigated

  18. Predicting core losses and efficiency of SRM in continuous current mode of operation using improved analytical technique

    Energy Technology Data Exchange (ETDEWEB)

    Parsapour, Amir, E-mail: amirparsapour@gmail.com [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Dehkordi, Behzad Mirzaeian, E-mail: mirzaeian@eng.ui.ac.ir [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Moallem, Mehdi, E-mail: moallem@cc.iut.ac.ir [Department of Electrical Engineering, Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2015-03-15

    In applications in which the high torque per ampere at low speed and rated power at high speed are required, the continuous current method is the best solution. However, there is no report on calculating the core loss of SRM in continuous current mode of operation. Efficiency and iron loss calculation which are complex tasks in case of conventional mode of operation is even more involved in continuous current mode of operation. In this paper, the Switched Reluctance Motor (SRM) is modeled using finite element method and core loss and copper loss of SRM in discontinuous and continuous current modes of operation are calculated using improved analytical techniques to include the minor loop losses in continuous current mode of operation. Motor efficiency versus speed in both operation modes is obtained and compared. - Highlights: • Continuous current method for Switched Reluctance Motor (SRM) is explained. • An improved analytical technique is presented for SRM core loss calculation. • SRM losses in discontinuous and continuous current operation modes are presented. • Effect of mutual inductances on SRM performance is investigated.

  19. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.

    Science.gov (United States)

    Isley, Michael R; Zhang, Xiao-Feng; Balzer, Jeffrey R; Leppanen, Ronald E

    2012-06-01

    Unequivocally, pedicle screw instrumentation has evolved as a primary construct for the treatment of both common and complex spinal disorders. However an inevitable and potentially major complication associated with this type of surgery is misplacement of a pedicle screw(s) which may result in neural and vascular complications, as well as impair the biomechanical stability of the spinal instrumentation resulting in loss of fixation. In light of these potential surgical complications, critical reviews of outcome data for treatment of chronic, low-back pain using pedicle screw instrumentation concluded that "pedicle screw fixation improves radiographically demonstrated fusion rates;" however the expense and complication rates for such constructs are considerable in light of the clinical benefit (Resnick et al. 2005a). Currently, neuromonitoring using free-run and evoked (triggered) electromyography (EMG) is widely used and advocated for safer and more accurate placement of pedicle screws during open instrumentation procedures, and more recently, guiding percutaneous placement (minimally invasive) where the pedicle cannot be easily inspected visually. The latter technique, evoked or triggered EMG when applied to pedicle screw instrumentation surgeries, has been referred to as the pedicle screw stimulation technique. As concluded in the Position Statement by the American Society of Neurophysiological Monitoring (ASNM), multimodality neuromonitoring using free-run EMG and the pedicle screw stimulation technique was considered a practice option and not yet a standard of care (Leppanen 2005). Subsequently, the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Joint Section on Disorders of the Spine and Peripheral Nerves published their "Guidelines for the Performance of Fusion Procedures for Degenerative Disease of the Lumbar Spine" (Heary 2005, Resnick et al. 2005a, Resnick et al. 2005b). It was concluded that the "primary

  20. Petroleum Pumps’ Current and Vibration Signatures Analysis Using Wavelet Coherence Technique

    Directory of Open Access Journals (Sweden)

    Rmdan Shnibha

    2013-01-01

    Full Text Available Vibration analysis is widely used for rotating machinery diagnostics; however measuring vibration of operational oil well pumps is not possible. The pump’s driver’s current signatures may provide condition-related information without the need for an access to the pump itself. This paper investigates the degree of relationship between the pump’s driver’s current signatures and its induced vibration. This relationship between the driver’s current signatures (DCS and its vibration signatures (DVS is studied by calculating magnitude-squared coherence and phase coherence parameters at a certain frequency band using continuous wavelet transform (CWT. The CWT coherence-based technique allows better analysis of temporal evolution of the frequency content of dynamic signals and areas in the time-frequency plane where the two signals exhibit common power or consistent phase behaviour indicating a relationship between the signals. This novel approach is validated by experimental data acquired from 3 kW petroleum pump’s driver. Both vibration and current signatures were acquired under different speed and load conditions. The outcomes of this research suggest the use of DCS analysis as reliable and inexpensive condition monitoring tool, which could be implemented for oil pumps, real-time monitoring associated with condition-based maintenance (CBM program.

  1. Corrosion rate transients observed by linear polarization techniques at Zr-1%Nb alloy

    International Nuclear Information System (INIS)

    Beran, J.; Cerny, K.

    1997-01-01

    Momentary corrosion rate of Zr-1%Nb alloy during nonisothermal autoclave experiments at temperature up to 328 deg. C in various solutions was determined by T/R p values (T - absolute temperature, R p - polarization resistance), multiplied by temperature independent conversion factor. This factor was found by comparison of conventional corrosion loss evaluation with electrochemical measurements. Corrosion rate transients in boric acid solutions and in lithium hydroxide differed significantly. Great differences were also found in stabilized corrosion rates at the end of experiments. Temperature irregularities caused considerable changes in corrosion rate. (author). 5 refs, 5 figs, 1 tab

  2. Corrosion rate transients observed by linear polarization techniques at Zr-1%Nb alloy

    Energy Technology Data Exchange (ETDEWEB)

    Beran, J; Cerny, K [ZJS SKODA plc., Pelzen (Czech Republic)

    1997-02-01

    Momentary corrosion rate of Zr-1%Nb alloy during nonisothermal autoclave experiments at temperature up to 328 deg. C in various solutions was determined by T/R{sub p} values (T - absolute temperature, R{sub p}- polarization resistance), multiplied by temperature independent conversion factor. This factor was found by comparison of conventional corrosion loss evaluation with electrochemical measurements. Corrosion rate transients in boric acid solutions and in lithium hydroxide differed significantly. Great differences were also found in stabilized corrosion rates at the end of experiments. Temperature irregularities caused considerable changes in corrosion rate. (author). 5 refs, 5 figs, 1 tab.

  3. Transient multilingual communities as a field of investigation

    DEFF Research Database (Denmark)

    Mortensen, Janus

    2017-01-01

    A key assumption in linguistic anthropology and sociolinguistics has traditionally been that interaction within communities tends to proceed on the basis of some degree of shared understanding of social and linguistic norms. However, in transient multilingual communities, defined here as social...... configurations where people from diverse sociocultural and linguistic backgrounds come together (physically or otherwise) for a limited period of time around a shared activity, such shared assumptions cannot be assumed to be in place a priori. By examining the social and linguistic processes that characterize...... transient communities, researchers are invited to analyze and theorize meaning-making in ways that hold the potential to enrich current work at the interface between sociolinguistics and linguistic anthropology. The article aims to take a first step in this direction by offering a definition...

  4. Work plan: transient release from LMFBR fuel

    International Nuclear Information System (INIS)

    Kress, T.S.; Parker, G.W.; Fontana, M.H.

    1975-09-01

    The proposed LMFBR Transient Release Program at ORNL is designed to investigate, by means of ex-reactor experiments and analytical modeling, the release and transport of fuel, fission products, and transuranic elements from fast reactor cores in the event of certain hypothetical accidents. It is desired to experimentally produce energy depositions that are characteristic of severe hypothetical reactor transients by the application of direct electrical current to mixed-oxide fuels under sodium. The experimental program includes tests with and without sodium, investigations of alternative methods of generating fuel and sodium aerosols, the use of UO 2 as a fuel simulant, additions of tracers as fission product simulants, effects of radiation, and under-water and under-sodium efforts to study the behavior of the vapor bubble itself. Analytical modeling will accompany all phases of the program, and the data will be correlated with models developed. 21 references. (auth)

  5. Real-time Transients from Palomar-QUEST Synoptic Sky Survey

    Science.gov (United States)

    Mahabal, Ashish A.; Drake, A.; Djorgovski, S. G.; Donalek, C.; Glikman, E.; Graham, M. J.; Williams, R.; Baltay, C.; Rabinowitz, D.; Bauer, A.; Ellman, N.; Lauer, R.; PQ Team Indiana

    2006-12-01

    The data from the driftscans of the Palomar-QUEST synoptic sky survey is now routinely processed in real-time. We describe here the various components of the pipeline. We search for both variable and transient objects, including supernovae, variable AGN, GRB orphan afterglows, cataclysmic variables, interesting stellar flares, novae, other types of variable stars, and do not exclude the possibility of even entirely new types of objects or phenomena. In order to flag as many asteroids as possible we have been doing two 4-hour scans of the same area covering 250 sq. deg and detect over a million sources. Flagging a source as a candidate transient requires detection in at least two filters besides its absence in fiducial sky constructed from past images. We use various software filters to eliminate instrument artifacts, and false alarms due to the proximity of bright, saturated stars which dominate the initial detection rate. This leaves up to a couple of hundred asteroids and genuine transients. Previously known asteroids are flagged through an automated comparison with a databases of known asteroids, and new ones through apparent motion. In the end, we have typically 10 20 astrophysical transients remaining per night, and we are currently working on their automated classification, and spectroscopic follow-up. We present preliminary results from real-time follow-up of a few candidates carried out with the Palomar 200-inch telescope as part of a pilot project. Finally we outline the plans for the much harder problem of classifying the transients more accurately for distribution through VOEventNet to astronomers interested only in specific types of transients, more details and overall setting of which is covered in our VOEventNet poster (Drake et al.)

  6. Extensions of the MCNP5 and TRIPOLI4 Monte Carlo Codes for Transient Reactor Analysis

    Science.gov (United States)

    Hoogenboom, J. Eduard; Sjenitzer, Bart L.

    2014-06-01

    To simulate reactor transients for safety analysis with the Monte Carlo method the generation and decay of delayed neutron precursors is implemented in the MCNP5 and TRIPOLI4 general purpose Monte Carlo codes. Important new variance reduction techniques like forced decay of precursors in each time interval and the branchless collision method are included to obtain reasonable statistics for the power production per time interval. For simulation of practical reactor transients also the feedback effect from the thermal-hydraulics must be included. This requires coupling of the Monte Carlo code with a thermal-hydraulics (TH) code, providing the temperature distribution in the reactor, which affects the neutron transport via the cross section data. The TH code also provides the coolant density distribution in the reactor, directly influencing the neutron transport. Different techniques for this coupling are discussed. As a demonstration a 3x3 mini fuel assembly with a moving control rod is considered for MCNP5 and a mini core existing of 3x3 PWR fuel assemblies with control rods and burnable poisons for TRIPOLI4. Results are shown for reactor transients due to control rod movement or withdrawal. The TRIPOLI4 transient calculation is started at low power and includes thermal-hydraulic feedback. The power rises about 10 decades and finally stabilises the reactor power at a much higher level than initial. The examples demonstrate that the modified Monte Carlo codes are capable of performing correct transient calculations, taking into account all geometrical and cross section detail.

  7. Extensions of the MCNP5 and TRIPOLI4 Monte Carlo codes for transient reactor analysis

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.

    2013-01-01

    To simulate reactor transients for safety analysis with the Monte Carlo method the generation and decay of delayed neutron precursors is implemented in the MCNP5 and TRIPOLI4 general purpose Monte Carlo codes. Important new variance reduction techniques like forced decay of precursors in each time interval and the branch-less collision method are included to obtain reasonable statistics for the power production per time interval. For simulation of practical reactor transients also the feedback effect from the thermal-hydraulics must be included. This requires the coupling of the Monte Carlo code with a thermal-hydraulics (TH) code, providing the temperature distribution in the reactor, which affects the neutron transport via the cross section data. The TH code also provides the coolant density distribution in the reactor, directly influencing the neutron transport. Different techniques for this coupling are discussed. As a demonstration a 3*3 mini fuel assembly with a moving control rod is considered for MCNP5 and a mini core existing of 3*3 PWR fuel assemblies with control rods and burnable poisons for TRIPOLI4. Results are shown for reactor transients due to control rod movement or withdrawal. The TRIPOLI4 transient calculation is started at low power and includes thermal-hydraulic feedback. The power rises about 10 decades and finally stabilises the reactor power at a much higher level than initial. The examples demonstrate that the modified Monte Carlo codes are capable of performing correct transient calculations, taking into account all geometrical and cross section detail. (authors)

  8. Transient photocurrent in molecular junctions: singlet switching on and triplet blocking.

    Science.gov (United States)

    Petrov, E G; Leonov, V O; Snitsarev, V

    2013-05-14

    The kinetic approach adapted to describe charge transmission in molecular junctions, is used for the analysis of the photocurrent under conditions of moderate light intensity of the photochromic molecule. In the framework of the HOMO-LUMO model for the single electron molecular states, the analytic expressions describing the temporary behavior of the transient and steady state sequential (hopping) as well as direct (tunnel) current components have been derived. The conditions at which the current components achieve their maximal values are indicated. It is shown that if the rates of charge transmission in the unbiased molecular diode are much lower than the intramolecular singlet-singlet excitation/de-excitation rate, and the threefold degenerated triplet excited state of the molecule behaves like a trap blocking the charge transmission, a possibility of a large peak-like transient switch-on photocurrent arises.

  9. Transient insomnia versus chronic insomnia: a comparison study of sleep-related psychological/behavioral characteristics.

    Science.gov (United States)

    Yang, Chien-Ming; Lin, Shih-Chun; Cheng, Chung-Ping

    2013-10-01

    Vulnerability to transient insomnia is regarded as a predisposing factor for chronic insomnia. However, most individuals with transient insomnia do not develop chronic insomnia. The current study investigated the differential contributing factors for these two conditions to further the understanding of this phenomenon. Chronic insomnia patients and normal sleepers with high and low vulnerability to transient insomnia completed measures of pre-sleep arousal, dysfunctional sleep beliefs, and sleep-related safety behaviors. Both cognitive and somatic pre-sleep arousals were identified as significant predictors for transient insomnia. Dysfunctional beliefs regarding worry about insomnia and cognitive arousal were predictors for chronic insomnia. Sleep-related safety behavior, although correlated with insomnia severity, was not a significant predictor for both conditions. Dysfunctional beliefs associated with worry and losing control over sleep are the most critical factors in differentiating chronic insomnia from transient insomnia. These factors should be addressed to help prevent individuals with high sleep vulnerability from developing chronic sleep disturbance. © 2013 Wiley Periodicals, Inc.

  10. Current techniques for visualizing RNA in cells [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Lilith V.J.C. Mannack

    2016-04-01

    Full Text Available Labeling RNA is of utmost interest, particularly in living cells, and thus RNA imaging is an emerging field. There are numerous methods relying on different concepts ranging from hybridization-based probes, over RNA-binding proteins to chemo-enzymatic modification of RNA. These methods have different benefits and limitations. This review aims to outline the current state-of-the-art techniques and point out their benefits and limitations.

  11. Code Coupling for Multi-Dimensional Core Transient Analysis

    International Nuclear Information System (INIS)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il

    2015-01-01

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident

  12. Code Coupling for Multi-Dimensional Core Transient Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il [KEPCO NF, Daejeon (Korea, Republic of)

    2015-05-15

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident.

  13. SCANAIR: A transient fuel performance code

    International Nuclear Information System (INIS)

    Moal, Alain; Georgenthum, Vincent; Marchand, Olivier

    2014-01-01

    Highlights: • Since the early 1990s, the code SCANAIR is developed at IRSN. • The software focuses on studying fast transients such as RIA in light water reactors. • The fuel rod modelling is based on a 1.5D approach. • Thermal and thermal-hydraulics, mechanical and gas behaviour resolutions are coupled. • The code is used for safety assessment and integral tests analysis. - Abstract: Since the early 1990s, the French “Institut de Radioprotection et de Sûreté Nucléaire” (IRSN) has developed the SCANAIR computer code with the view to analysing pressurised water reactor (PWR) safety. This software specifically focuses on studying fast transients such as reactivity-initiated accidents (RIA) caused by possible ejection of control rods. The code aims at improving the global understanding of the physical mechanisms governing the thermal-mechanical behaviour of a single rod. It is currently used to analyse integral tests performed in CABRI and NSRR experimental reactors. The resulting validated code is used to carry out studies required to evaluate margins in relation to criteria for different types of fuel rods used in nuclear power plants. Because phenomena occurring during fast power transients are complex, the simulation in SCANAIR is based on a close coupling between several modules aimed at modelling thermal, thermal-hydraulics, mechanical and gas behaviour. During the first stage of fast power transients, clad deformation is mainly governed by the pellet–clad mechanical interaction (PCMI). At the later stage, heat transfers from pellet to clad bring the cladding material to such high temperatures that the boiling crisis might occurs. The significant over-pressurisation of the rod and the fact of maintaining the cladding material at elevated temperatures during a fairly long period can lead to ballooning and possible clad failure. A brief introduction describes the context, the historical background and recalls the main phenomena involved under

  14. SCANAIR: A transient fuel performance code

    Energy Technology Data Exchange (ETDEWEB)

    Moal, Alain, E-mail: alain.moal@irsn.fr; Georgenthum, Vincent; Marchand, Olivier

    2014-12-15

    Highlights: • Since the early 1990s, the code SCANAIR is developed at IRSN. • The software focuses on studying fast transients such as RIA in light water reactors. • The fuel rod modelling is based on a 1.5D approach. • Thermal and thermal-hydraulics, mechanical and gas behaviour resolutions are coupled. • The code is used for safety assessment and integral tests analysis. - Abstract: Since the early 1990s, the French “Institut de Radioprotection et de Sûreté Nucléaire” (IRSN) has developed the SCANAIR computer code with the view to analysing pressurised water reactor (PWR) safety. This software specifically focuses on studying fast transients such as reactivity-initiated accidents (RIA) caused by possible ejection of control rods. The code aims at improving the global understanding of the physical mechanisms governing the thermal-mechanical behaviour of a single rod. It is currently used to analyse integral tests performed in CABRI and NSRR experimental reactors. The resulting validated code is used to carry out studies required to evaluate margins in relation to criteria for different types of fuel rods used in nuclear power plants. Because phenomena occurring during fast power transients are complex, the simulation in SCANAIR is based on a close coupling between several modules aimed at modelling thermal, thermal-hydraulics, mechanical and gas behaviour. During the first stage of fast power transients, clad deformation is mainly governed by the pellet–clad mechanical interaction (PCMI). At the later stage, heat transfers from pellet to clad bring the cladding material to such high temperatures that the boiling crisis might occurs. The significant over-pressurisation of the rod and the fact of maintaining the cladding material at elevated temperatures during a fairly long period can lead to ballooning and possible clad failure. A brief introduction describes the context, the historical background and recalls the main phenomena involved under

  15. ATHENA simulations of divertor loss of heat sink transient for the GSSR - Final report with updates

    Energy Technology Data Exchange (ETDEWEB)

    Sponton, L.L

    2001-05-01

    The ITER-FEAT Generic Site Safety Report includes evaluations of the consequences of various types of conceivable transients that can occur during operation. The transients that have to be considered in this respect are specified in the Accident Analysis Specifications document of the safety report. For the divertor primary heat transport system the ranges of transients include amongst others a loss of heat sink at full fusion power operation. The thermal-hydraulic consequences related to the coolability of the divertor primary heat transport system components for this transient have been evaluated and summarised in the safety report and in the current report an overview of those efforts and associated outcome is provided. The analyses have been made with the ATHENA thermal-hydraulic code using a separately developed ATHENA model of the ITER-FEAT divertor cooling system. In the current report results from calculations with an updated pressurizer model and pressurizer control system are outlined. The results show that the pressurizer safety valve does not open, that the pressurizer level increase is moderate and that no temperature increases jeopardize the structure integrity.

  16. ATHENA simulations of divertor loss of heat sink transient for the GSSR - Final report with updates

    International Nuclear Information System (INIS)

    Sponton, L.L.

    2001-05-01

    The ITER-FEAT Generic Site Safety Report includes evaluations of the consequences of various types of conceivable transients that can occur during operation. The transients that have to be considered in this respect are specified in the Accident Analysis Specifications document of the safety report. For the divertor primary heat transport system the ranges of transients include amongst others a loss of heat sink at full fusion power operation. The thermal-hydraulic consequences related to the coolability of the divertor primary heat transport system components for this transient have been evaluated and summarised in the safety report and in the current report an overview of those efforts and associated outcome is provided. The analyses have been made with the ATHENA thermal-hydraulic code using a separately developed ATHENA model of the ITER-FEAT divertor cooling system. In the current report results from calculations with an updated pressurizer model and pressurizer control system are outlined. The results show that the pressurizer safety valve does not open, that the pressurizer level increase is moderate and that no temperature increases jeopardize the structure integrity

  17. Applications of pulsed Eddy Current (PEC) technique on defect and material assessment

    International Nuclear Information System (INIS)

    Nurul A'in Ahmad Latif; Noorhazleena Azaman; Ilham Mukriz Zainal Abidin

    2014-01-01

    The pulsed eddy current (PEC) is an emerging electromagnetic method and widely used in multiple field including aerospace, petrochemical, industry and transportation. PEC mainly depends on the multiple variables such as peak value and rising time to detect and quantify the defects. Apart of its advantage as non contacting technique, it has ability on conducting surface and subsurface detection. Additionally, PEC is high sensitive to variety parameters that are inherent in the flaws. Compare to conventional eddy current, PEC allows deeper penetration as it is a combination from multiple frequencies. This paper demonstrates the abilities of PEC technique performing multiple testing in various fields such as conducting conductivity testing, measuring the material thickness and identifying depth of the defects. The conductivity testing will be performed on multiple materials such as aluminium, stainless steel, copper, austenitic steel and titanium. To measure the material thicknesses, PEC testing will be conducted on the multi layered specimen with the different thickness. Meanwhile to identify depth of defects, the testing will be carried out using a stainless steel calibration block contains multiple length of defect. For the validation purposes, all the results generate through the experiments will be compared with simulation results produced using dedicated software, COMSOL. (author)

  18. Modelling and transient simulation of water flow in pipelines using WANDA Transient software

    Directory of Open Access Journals (Sweden)

    P.U. Akpan

    2017-09-01

    Full Text Available Pressure transients in conduits such as pipelines are unsteady flow conditions caused by a sudden change in the flow velocity. These conditions might cause damage to the pipelines and its fittings if the extreme pressure (high or low is experienced within the pipeline. In order to avoid this occurrence, engineers usually carry out pressure transient analysis in the hydraulic design phase of pipeline network systems. Modelling and simulation of transients in pipelines is an acceptable and cost effective method of assessing this problem and finding technical solutions. This research predicts the pressure surge for different flow conditions in two different pipeline systems using WANDA Transient simulation software. Computer models were set-up in WANDA Transient for two different systems namely; the Graze experiment (miniature system and a simple main water riser system based on some initial laboratory data and system parameters. The initial laboratory data and system parameters were used for all the simulations. Results obtained from the computer model simulations compared favourably with the experimental results at Polytropic index of 1.2.

  19. Deep knowledge expert system for diagnosis of multiple-failure severe transients in nuclear power plant

    International Nuclear Information System (INIS)

    Martin, R.P.; Nassersharif, B.

    1987-01-01

    TAMUS (Transient Analysis of MUltiple-failure Simulations) is a prototype expert system which is the result of a project investigating and implementing event confidence-levels (used by reactor safety experts in reactor transient analysis) in the form of an expert system. Currently, TAMUS is designed to diagnose reactor transients by analyzing simulated sensor and plant thermal hydraulic information from a system simulation. TAMUS uses a knowledge base of existing emergency nuclear plant operating guidelines and detailed thermal-hydraulic calculating results correlated to confidence-levels. TAMUS can diagnose a number of reactor transients (for example, loss-of-coolant accidents, steam-generator-tube ruptures, loss-of-offsite power, etc.). Future work includes the expansion of the knowledge base and improvement of the deep-knowledge qualitative models

  20. RFI flagging implications for short-duration transients

    Science.gov (United States)

    Cendes, Y.; Prasad, P.; Rowlinson, A.; Wijers, R. A. M. J.; Swinbank, J. D.; Law, C. J.; van der Horst, A. J.; Carbone, D.; Broderick, J. W.; Staley, T. D.; Stewart, A. J.; Huizinga, F.; Molenaar, G.; Alexov, A.; Bell, M. E.; Coenen, T.; Corbel, S.; Eislöffel, J.; Fender, R.; Grießmeier, J.-M.; Jonker, P.; Kramer, M.; Kuniyoshi, M.; Pietka, M.; Stappers, B.; Wise, M.; Zarka, P.

    2018-04-01

    With their wide fields of view and often relatively long coverage of any position in the sky in imaging survey mode, modern radio telescopes provide a data stream that is naturally suited to searching for rare transients. However, Radio Frequency Interference (RFI) can show up in the data stream in similar ways to such transients, and thus the normal pre-treatment of filtering RFI (flagging) may also remove astrophysical transients from the data stream before imaging. In this paper we investigate how standard flagging affects the detectability of such transients by examining the case of transient detection in an observing mode used for Low Frequency Array (LOFAR; van Haarlem et al., 2013) surveys. We quantify the fluence range of transients that would be detected, and the reduction of their SNR due to partial flagging. We find that transients with a duration close to the integration sampling time, as well as bright transients with durations on the order of tens of seconds, are completely flagged. For longer transients on the order of several tens of seconds to minutes, the flagging effects are not as severe, although part of the signal is lost. For these transients, we present a modified flagging strategy which mitigates the effect of flagging on transient signals. We also present a script which uses the differences between the two strategies, and known differences between transient RFI and astrophysical transients, to notify the observer when a potential transient is in the data stream.

  1. Analysis of Current Visualization Techniques and Main Challenges for the Future

    Directory of Open Access Journals (Sweden)

    Manuel Pérez Cota

    2017-08-01

    Full Text Available The big amount of data generated nowadays are being used by Big Data tools to generate knowledge and to facilitate the decision-making. However, this situation creates a new challenge: how to visualize all these data without losing mid/long term crucial information. The purpose of this article is to analyze the state of the art on massive data visualization, main problems and challenges of information representation current techniques as well as the evolution of the tools and the future of them, in other words, new functionalities to offer.

  2. Investigation of transient melting of tungsten by ELMs in ASDEX Upgrade

    International Nuclear Information System (INIS)

    Krieger, K; Sieglin, B; Balden, M; De Marne, P; Nille, D; Rohde, V; Faitsch, M; Giannone, L; Herrmann, A; Coenen, J W; Göths, B; Laggner, F; Matthews, G F; Dejarnac, R; Horacek, J; Komm, M; Pitts, R A; Ratynskaia, S; Thoren, E; Tolias, P

    2017-01-01

    Repetitive melting of tungsten by power transients originating from edge localized modes (ELMs) has been studied in the tokamak experiment ASDEX Upgrade. Tungsten samples were exposed to H-mode discharges at the outer divertor target plate using the Divertor Manipulator II system. The exposed sample was designed with an elevated sloped surface inclined against the incident magnetic field to increase the projected parallel power flux to a level were transient melting by ELMs would occur. Sample exposure was controlled by moving the outer strike point to the sample location. As extension to previous melt studies in the new experiment both the current flow from the sample to vessel potential and the local surface temperature were measured with sufficient time resolution to resolve individual ELMs. The experiment provided for the first time a direct link of current flow and surface temperature during transient ELM events. This allows to further constrain the MEMOS melt motion code predictions and to improve the validation of its underlying model assumptions. Post exposure ex situ analysis of the retrieved samples confirms the decreased melt motion observed at shallower magnetic field line to surface angles compared to that at leading edges exposed to the parallel power flux. (paper)

  3. Transient well flow in layered aquifer systems: the uniform well-face drawdown solution.

    NARCIS (Netherlands)

    Hemker, C.J.

    1999-01-01

    Previously a hybrid analytical-numerical solution for the general problem of computing transient well flow in vertically heterogeneous aquifers was proposed by the author. The radial component of flow was treated analytically, while the finite-difference technique was used for the vertical flow

  4. Transient gels in colloid-polymer mixtures studied with fluorescence confocal scanning laser microscopy

    NARCIS (Netherlands)

    Verhaegh, N.A.M.; Asnaghi, D.; Lekkerkerker, H.N.W.

    1999-01-01

    We study the structure and the time evolution of transient gels formed in colloid-polymer mixtures, by means of uorescence Confocal Scanning Laser Microscopy (CSLM). This technique is used in conjunction with novel colloidal silica particles containing a uorescent core. The confocal micrographs

  5. A transient-enhanced NMOS low dropout voltage regulator with parallel feedback compensation

    International Nuclear Information System (INIS)

    Wang Han; Tan Lin

    2016-01-01

    This paper presents a transient-enhanced NMOS low-dropout regulator (LDO) for portable applications with parallel feedback compensation. The parallel feedback structure adds a dynamic zero to get an adequate phase margin with a load current variation from 0 to 1 A. A class-AB error amplifier and a fast charging/discharging unit are adopted to enhance the transient performance. The proposed LDO has been implemented in a 0.35 μm BCD process. From experimental results, the regulator can operate with a minimum dropout voltage of 150 mV at a maximum 1 A load and I Q of 165 μA. Under the full range load current step, the voltage undershoot and overshoot of the proposed LDO are reduced to 38 mV and 27 mV respectively. (paper)

  6. SPIRITS: SPitzer InfraRed Intensive Transients Survey

    Science.gov (United States)

    Kasliwal, Mansi; Jencson, Jacob; Lau, Ryan; Masci, Frank; Helou, George; Williams, Robert; Bally, John; Bond, Howard; Whitelock, Patricia; Cody, Ann Marie; Gehrz, Robert; Tinyanont, Samaporn; Smith, Nathan; Surace, Jason; Armus, Lee; Cantiello, Matteo; Langer, Norbert; Levesque, Emily; Mohamed, Shazrene; Ofek, Eran; Parthasarathy, Mudumba; van Dyk, Schuyler; Boyer, Martha; Phillips, Mark; Hsiao, Eric; Morrell, Nidia; Perley, Dan; Gonzalez, Consuelo; Contreras, Carlos; Jones, Olivia; Ressler, Michael; Adams, Scott; Moore, Anna; Cook, David; Fox, Ori; Johansson, Joel; Khan, Rubab; Monson, Andrew; Hankins, Matthew; Goldman, Steven; Jacob, Jencson

    2018-05-01

    Spitzer is pioneering a systematic exploration of the dynamic infrared sky. Our SPitzer InfraRed Intensive Transients Survey (SPIRITS) has already discovered 78 explosive transients and 2457 eruptive variables. Of these 78 infrared transients, 60 are so red that they are devoid of optical counterparts and we call them SPRITEs (eSPecially Red Intermediate-luminosity Transient Events). The nature of SPRITEs is unknown and progress on deciphering the explosion physics depends on mid-IR spectroscopy. Multiple physical origins have been proposed including stellar merger, birth of a massive binary, electron capture supernova and stellar black hole formation. Hence, we propose a modest continuation of SPIRITS, focusing on discovering and monitoring SPRITEs, in preparation for follow-up with the James Webb Space Telescope (JWST). As the SPRITEs evolve and cool, the bulk of the emission shifts to longer wavelengths. MIRI aboard JWST will be the only available platform in the near future capable of characterizing SPRITEs out to 28 um. Specifically, the low resolution spectrometer would determine dust mass, grain chemistry, ice abundance and energetics to disentangle the proposed origins. The re-focused SPIRITS program consists of continued Spitzer monitoring of those 106 luminous galaxies that are known SPRITE hosts or are most likely to host new SPRITEs. Scaling from the SPIRITS discovery rate, we estimate finding 10 new SPRITEs and 2-3 new supernovae in Cycle 14. The SPIRITS team remains committed to extensive ground-based follow-up. The Spitzer observations proposed here are essential for determining the final fates of active SPRITEs as well as bridging the time lag between the current SPIRITS survey and JWST launch.

  7. Time-accurate CFD conjugate analysis of transient measurements of the heat-transfer coefficient in a channel with pin fins

    Directory of Open Access Journals (Sweden)

    Tom I-P. Shih

    2013-03-01

    Full Text Available Heat-transfer coefficients (HTC on surfaces exposed to convection environments are often measured by transient techniques such as thermochromic liquid crystal (TLC or infrared thermography. In these techniques, the surface temperature is measured as a function of time, and that measurement is used with the exact solution for unsteady, zero-dimensional (0-D or one-dimensional (1-D heat conduction into a solid to calculate the local HTC. When using the 0-D or 1-D exact solutions, the transient techniques assume the HTC and the free-stream or bulk temperature characterizing the convection environment to be constants in addition to assuming the conduction into the solid to be 0-D or 1-D. In this study, computational fluid dynamics (CFD conjugate analyses were performed to examine the errors that might be invoked by these assumptions for a problem, where the free-stream/bulk temperature and the heat-transfer coefficient vary appreciably along the surface and where conduction into the solid may not be 0-D or 1-D. The problem selected to assess these errors is flow and heat transfer in a channel lined with a staggered array of pin fins. This conjugate study uses three-dimensional (3-D unsteady Reynolds-averaged Navier–Stokes (RANS closed by the shear-stress transport (SST turbulence model for the gas phase (wall functions not used and the Fourier law for the solid phase. The errors in the transient techniques are assessed by comparing the HTC predicted by the time-accurate conjugate CFD with those predicted by the 0-D and 1-D exact solutions, where the surface temperatures needed by the exact solutions are taken from the time-accurate conjugate CFD solution. Results obtained show that the use of the 1-D exact solution for the semi-infinite wall to give reasonably accurate “transient” HTC (less than 5% relative error. Transient techniques that use the 0-D exact solution for the pin fins were found to produce large errors (up to 160% relative error

  8. A numerical algorithm to evaluate the transient response for a synchronous scanning streak camera using a time-domain Baum–Liu–Tesche equation

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); He, Jiai [School of Computer and Communication, Lanzhou University of Technology, Lanzhou, Gansu 730050 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2016-10-01

    The transient response is of great influence on the electromagnetic compatibility of synchronous scanning streak cameras (SSSCs). In this paper we propose a numerical method to evaluate the transient response of the scanning deflection plate (SDP). First, we created a simplified circuit model for the SDP used in an SSSC, and then derived the Baum–Liu–Tesche (BLT) equation in the frequency domain. From the frequency-domain BLT equation, its transient counterpart was derived. These parameters, together with the transient-BLT equation, were used to compute the transient load voltage and load current, and then a novel numerical method to fulfill the continuity equation was used. Several numerical simulations were conducted to verify this proposed method. The computed results were then compared with transient responses obtained by a frequency-domain/fast Fourier transform (FFT) method, and the accordance was excellent for highly conducting cables. The benefit of deriving the BLT equation in the time domain is that it may be used with slight modifications to calculate the transient response and the error can be controlled by a computer program. The result showed that the transient voltage was up to 1000 V and the transient current was approximately 10 A, so some protective measures should be taken to improve the electromagnetic compatibility.

  9. A numerical algorithm to evaluate the transient response for a synchronous scanning streak camera using a time-domain Baum–Liu–Tesche equation

    International Nuclear Information System (INIS)

    Pei, Chengquan; Tian, Jinshou; Wu, Shengli; He, Jiai; Liu, Zhen

    2016-01-01

    The transient response is of great influence on the electromagnetic compatibility of synchronous scanning streak cameras (SSSCs). In this paper we propose a numerical method to evaluate the transient response of the scanning deflection plate (SDP). First, we created a simplified circuit model for the SDP used in an SSSC, and then derived the Baum–Liu–Tesche (BLT) equation in the frequency domain. From the frequency-domain BLT equation, its transient counterpart was derived. These parameters, together with the transient-BLT equation, were used to compute the transient load voltage and load current, and then a novel numerical method to fulfill the continuity equation was used. Several numerical simulations were conducted to verify this proposed method. The computed results were then compared with transient responses obtained by a frequency-domain/fast Fourier transform (FFT) method, and the accordance was excellent for highly conducting cables. The benefit of deriving the BLT equation in the time domain is that it may be used with slight modifications to calculate the transient response and the error can be controlled by a computer program. The result showed that the transient voltage was up to 1000 V and the transient current was approximately 10 A, so some protective measures should be taken to improve the electromagnetic compatibility.

  10. Application of numerical analysis techniques to eddy current testing for steam generator tubes

    International Nuclear Information System (INIS)

    Morimoto, Kazuo; Satake, Koji; Araki, Yasui; Morimura, Koichi; Tanaka, Michio; Shimizu, Naoya; Iwahashi, Yoichi

    1994-01-01

    This paper describes the application of numerical analysis to eddy current testing (ECT) for steam generator tubes. A symmetrical and three-dimensional sinusoidal steady state eddy current analysis code was developed. This code is formulated by future element method-boundary element method coupling techniques, in order not to regenerate the mesh data in the tube domain at every movement of the probe. The calculations were carried out under various conditions including those for various probe types, defect orientations and so on. Compared with the experimental data, it was shown that it is feasible to apply this code to actual use. Furthermore, we have developed a total eddy current analysis system which consists of an ECT calculation code, an automatic mesh generator for analysis, a database and display software for calculated results. ((orig.))

  11. LLL transient-electromagnetics-measurement facility

    International Nuclear Information System (INIS)

    Deadrick, F.J.; Miller, E.K.; Hudson, H.G.

    1975-01-01

    The operation and hardware of the Lawrence Livermore Laboratory's transient-electromagnetics (EM)-measurement facility are described. The transient-EM range is useful for determining the time-domain transient responses of structures to incident EM pulses. To illustrate the accuracy and utility of the EM-measurement facility, actual experimental measurements are compared to numerically computed values

  12. Topside ionosphere of Mars: Variability, transient layers, and the role of crustal magnetic fields

    Science.gov (United States)

    Gopika, P. G.; Venkateswara Rao, N.

    2018-04-01

    The topside ionosphere of Mars is known to show variability and transient topside layers. In this study, we analyzed the electron density profiles measured by the radio occultation technique aboard the Mars Global Surveyor spacecraft to study the topside ionosphere of Mars. The electron density profiles that we used in the present study span between 1998 and 2005. All the measurements are done from the northern high latitudes, except 220 profiles which were measured in the southern hemisphere, where strong crustal magnetic fields are present. We binned the observations into six measurement periods: 1998, 1999-north, 1999-south, 2000-2001, 2002-2003, and 2004-2005. We found that the topside ionosphere in the southern high latitudes is more variable than that from the northern hemisphere. This feature is clearly seen with fluctuations of wavelengths less than 20 km. Some of the electron density profiles show a transient topside layer with a local maximum in electron density between 160 km and 210 km. The topside layer is more prone to occur in the southern hemispheric crustal magnetic field regions than in the other regions. In addition, the peak density of the topside layer is greater in regions of strong crustal magnetic fields than in other regions. The variability of the topside ionosphere and the peak density of the topside layer, however, do not show one-to-one correlation with the strength of the crustal magnetic fields and magnetic field inclination. The results of the present study are discussed in the light of current understanding on the topside ionosphere, transient topside layers, and the role of crustal magnetic fields on plasma motions.

  13. Transient coupled calculations of the Molten Salt Fast Reactor using the Transient Fission Matrix approach

    Energy Technology Data Exchange (ETDEWEB)

    Laureau, A., E-mail: laureau.axel@gmail.com; Heuer, D.; Merle-Lucotte, E.; Rubiolo, P.R.; Allibert, M.; Aufiero, M.

    2017-05-15

    Highlights: • Neutronic ‘Transient Fission Matrix’ approach coupled to the CFD OpenFOAM code. • Fission Matrix interpolation model for fast spectrum homogeneous reactors. • Application for coupled calculations of the Molten Salt Fast Reactor. • Load following, over-cooling and reactivity insertion transient studies. • Validation of the reactor intrinsic stability for normal and accidental transients. - Abstract: In this paper we present transient studies of the Molten Salt Fast Reactor (MSFR). This generation IV reactor is characterized by a liquid fuel circulating in the core cavity, requiring specific simulation tools. An innovative neutronic approach called “Transient Fission Matrix” is used to perform spatial kinetic calculations with a reduced computational cost through a pre-calculation of the Monte Carlo spatial and temporal response of the system. Coupled to this neutronic approach, the Computational Fluid Dynamics code OpenFOAM is used to model the complex flow pattern in the core. An accurate interpolation model developed to take into account the thermal hydraulics feedback on the neutronics including reactivity and neutron flux variation is presented. Finally different transient studies of the reactor in normal and accidental operating conditions are detailed such as reactivity insertion and load following capacities. The results of these studies illustrate the excellent behavior of the MSFR during such transients.

  14. Transient coupled calculations of the Molten Salt Fast Reactor using the Transient Fission Matrix approach

    International Nuclear Information System (INIS)

    Laureau, A.; Heuer, D.; Merle-Lucotte, E.; Rubiolo, P.R.; Allibert, M.; Aufiero, M.

    2017-01-01

    Highlights: • Neutronic ‘Transient Fission Matrix’ approach coupled to the CFD OpenFOAM code. • Fission Matrix interpolation model for fast spectrum homogeneous reactors. • Application for coupled calculations of the Molten Salt Fast Reactor. • Load following, over-cooling and reactivity insertion transient studies. • Validation of the reactor intrinsic stability for normal and accidental transients. - Abstract: In this paper we present transient studies of the Molten Salt Fast Reactor (MSFR). This generation IV reactor is characterized by a liquid fuel circulating in the core cavity, requiring specific simulation tools. An innovative neutronic approach called “Transient Fission Matrix” is used to perform spatial kinetic calculations with a reduced computational cost through a pre-calculation of the Monte Carlo spatial and temporal response of the system. Coupled to this neutronic approach, the Computational Fluid Dynamics code OpenFOAM is used to model the complex flow pattern in the core. An accurate interpolation model developed to take into account the thermal hydraulics feedback on the neutronics including reactivity and neutron flux variation is presented. Finally different transient studies of the reactor in normal and accidental operating conditions are detailed such as reactivity insertion and load following capacities. The results of these studies illustrate the excellent behavior of the MSFR during such transients.

  15. Transient Infrared Measurement of Laser Absorption Properties of Porous Materials

    Directory of Open Access Journals (Sweden)

    Marynowicz Andrzej

    2016-06-01

    Full Text Available The infrared thermography measurements of porous building materials have become more frequent in recent years. Many accompanying techniques for the thermal field generation have been developed, including one based on laser radiation. This work presents a simple optimization technique for estimation of the laser beam absorption for selected porous building materials, namely clinker brick and cement mortar. The transient temperature measurements were performed with the use of infrared camera during laser-induced heating-up of the samples’ surfaces. As the results, the absorbed fractions of the incident laser beam together with its shape parameter are reported.

  16. Transient Infrared Measurement of Laser Absorption Properties of Porous Materials

    Science.gov (United States)

    Marynowicz, Andrzej

    2016-06-01

    The infrared thermography measurements of porous building materials have become more frequent in recent years. Many accompanying techniques for the thermal field generation have been developed, including one based on laser radiation. This work presents a simple optimization technique for estimation of the laser beam absorption for selected porous building materials, namely clinker brick and cement mortar. The transient temperature measurements were performed with the use of infrared camera during laser-induced heating-up of the samples' surfaces. As the results, the absorbed fractions of the incident laser beam together with its shape parameter are reported.

  17. Switching transients in the MFTF yin-yang coils

    International Nuclear Information System (INIS)

    Owen, E.W.; Shimer, D.W.

    1982-01-01

    This report is a study of the transients caused by the fast dump of large superconducting coils. Theoretical analysis, computer simulation, and actual measurements are used. Theoretical analysis can only be applied to the simplest of models. In the computer simulations two models are used, one in which the coil is divided into ten segments and another in which a single coil is employed. The circuit breaker that interrupts the current to the power supply, causing a fast dump, is represented by a time and current dependent conductance. Actual measurements are limited to measurements made incidental to the coils' performance tests

  18. Scanning deep level transient spectroscopy using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Laird, J.S.; Bardos, R.A.; Saint, A.; Moloney, G.M.; Legge, G.F.J. [Melbourne Univ., Parkville, VIC (Australia)

    1993-12-31

    Traditionally the scanning ion microprobe has given little or no information regarding the electronic structure of materials in particular semiconductors. A new imaging technique called Scanning Ion Deep Level Transient Spectroscopy (SIDLTS) is presented which is able to spatially map alterations in the band gap structure of materials by lattice defects or impurities. 3 refs., 2 figs.

  19. Scanning deep level transient spectroscopy using an MeV ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Laird, J S; Bardos, R A; Saint, A; Moloney, G M; Legge, G F.J. [Melbourne Univ., Parkville, VIC (Australia)

    1994-12-31

    Traditionally the scanning ion microprobe has given little or no information regarding the electronic structure of materials in particular semiconductors. A new imaging technique called Scanning Ion Deep Level Transient Spectroscopy (SIDLTS) is presented which is able to spatially map alterations in the band gap structure of materials by lattice defects or impurities. 3 refs., 2 figs.

  20. Respiratory gated radiotherapy: current techniques and potential benefits

    International Nuclear Information System (INIS)

    Giraud, P.; Campana, F.; Rosenwald, J.C.; Cosset, J.M.; Reboul, F.; Garcia, R.; Clippe, S.; Carrie, C.; Dubray, B.

    2003-01-01

    Respiration-gated radiotherapy offers a significant potential for improvement in the irradiation of tumor sites affected by respiratory motion such as lung, breast and liver tumors. An increased conformality of irradiation fields leading to decreased complications rates of organs at risk (lung, heart...) is expected. Respiratory gating is in line with the need for improved precision required by radiotherapy techniques such as 3D conformal radiotherapy or intensity modulated radiotherapy. Reduction of respiratory motion can be achieved by using either breath hold techniques or respiration synchronized gating techniques. Breath-hold techniques can be achieved with active, in which airflow of the patient is temporarily blocked by a valve, or passive techniques, in which the patient voluntarily breath-hold. Synchronized gating techniques use external devices to predict the phase of the respiration cycle while the patient breaths freely. These techniques presently investigated in several medical centers worldwide. Although promising, the first results obtained in lung and liver cancer patients require confirmation. Physical, technical and physiological questions still remain to be answered. This paper describes the most frequently used gated techniques and the main published clinical reports on the use of respiration-gated radiotherapy in order to evaluate the impact of these techniques. (author)