WorldWideScience

Sample records for transfer spectrum measurement

  1. Beryllium phonon spectrum from cold neutron measurements

    International Nuclear Information System (INIS)

    Bulat, I.A.

    1979-01-01

    The inelastic coherent scattering of neutrons with the initial energy E 0 =4.65 MeV on the spectrometer according to the time of flight is studied in polycrystalline beryllium. The measurements are made for the scattering angles THETA=15, 30, 45, 60, 75 and 90 deg at 293 K. The phonon spectrum of beryllium, i-e. g(w) is reestablished from the experimental data. The data obtained are compared with the data of model calculations. It is pointed out that the phonon spectrum of beryllium has a bit excessive state density in the energy range from 10 to 30 MeV. It is caused by the insufficient statistical accuracy of the experiment at low energy transfer

  2. Spectrum and network measurements

    CERN Document Server

    Witte, Robert A

    2014-01-01

    This new edition of Spectrum and Network Measurements enables readers to understand the basic theory, relate it to measured results, and apply it when creating new designs. This comprehensive treatment of frequency domain measurements successfully consolidates all the pertinent theory into one text. It covers the theory and practice of spectrum and network measurements in electronic systems. It also provides thorough coverage of Fourier analysis, transmission lines, intermodulation distortion, signal-to-noise ratio and S-parameters.

  3. Enhanced signal dispersion in saturation transfer difference experiments by conversion to a 1D-STD-homodecoupled spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Pastor, Manuel; Vega-Vazquez, Marino [Universidade de Santiago de Compostela, Laboratorio Integral de Dinamica e Estructura de Biomoleculas Jose R. Carracido, Unidade de Resonancia Magnetica, Edificio CACTUS, RIAIDT (Spain); Capua, Antonia De [Seconda Universita degli Studi di Napoli, Dipartimento di Scienze Ambientali (Italy); Canales, Angeles [Centro de Investigaciones Biologicas, CSIC, Departamento de Estructura y funcion de proteinas (Spain); Andre, Sabine; Gabius, Hans-Joachim [Ludwig-Maximilians-Universitaet, Institut fuer Physiologische Chemie, Tieraerztliche Fakultaet (Germany); Jimenez-Barbero, Jesus [Centro de Investigaciones Biologicas, CSIC, Departamento de Estructura y funcion de proteinas (Spain)], E-mail: JJbarbero@cib.csic.es

    2006-10-15

    The saturation transfer difference (STD) experiment is a rich source of information on topological aspects of ligand binding to a receptor. The epitope mapping is based on a magnetization transfer after signal saturation from the receptor to the ligand, where interproton distances permit this process. Signal overlap in the STD spectrum can cause difficulties to correctly assign and/or quantitate the measured enhancements. To address this issue we report here a modified version of the routine experiment and a processing scheme that provides a 1D-STD homodecoupled spectrum (i.e. an experiment in which all STD signals appear as singlets) with line widths similar to those in original STD spectrum. These refinements contribute to alleviate problems of signal overlap. The experiment is based on 2D-J-resolved spectroscopy, one of the fastest 2D experiments under conventional data sampling in the indirect dimension, and provides excellent sensitivity, a key factor for the difference experiments.

  4. Measurements of ocean wave spectra and modulation transfer function with the airborne two-frequency scatterometer

    Science.gov (United States)

    Weissman, D. E.; Johnson, J. W.

    1986-01-01

    The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

  5. Measurements of ocean wave spectra and modulation transfer function with the airborne two frequency scatterometer

    Science.gov (United States)

    Weissman, D. E.; Johnson, J. W.

    1984-01-01

    The directional spectrum and the microwave modulation transfer function of ocean waves can be measured with the airborne two frequency scatterometer technique. Similar to tower based observations, the aircraft measurements of the Modulation Transfer Function (MTF) show that it is strongly affected by both wind speed and sea state. Also detected are small differences in the magnitudes of the MTF between downwind and upwind radar look directions, and variations with ocean wavenumber. The MTF inferred from the two frequency radar is larger than that measured using single frequency, wave orbital velocity techniques such as tower based radars or ROWS measurements from low altitude aircraft. Possible reasons for this are discussed. The ability to measure the ocean directional spectrum with the two frequency scatterometer, with supporting MTF data, is demonstrated.

  6. [Air Dielectric Barrier Discharge Emission Spectrum Measurement and Particle Analysis of Discharge Process].

    Science.gov (United States)

    Shen, Shuang-yan; Jin, Xing; Zhang, Peng

    2016-02-01

    The emission spectrum detection and diagnosis is one of the most common methods of application to the plasma. It provides wealth of information of the chemical and physical process of the plasma. The analysis of discharge plasma dynamic behavior plays an important role in the study of gas discharge mechanism and application. An air dielectric discharge spectrum measuring device was designed and the emission spectrum data was measured under the experimental condition. The plasma particles evolution was analyzed from the emission spectrum. The numerical calculation model was established and the density equation, energy transfer equation and the Boltzmann equation was coupled to analyze the change of the particle density to explain the emission spectrum characteristics. The results are that the particle density is growing with the increasing of reduced electric field. The particle density is one or two orders of magnitude difference for the same particle at the same moment for the reduced electric field of 40, 60 or 80 Td. A lot of N₂ (A³), N₂ (A³) and N₂ (C³) particles are generated by the electric field excitation. However, it transforms quickly due to the higher energy level. The transformation returns to the balance after the discharge of 10⁻⁶ s. The emission spectrometer measured in the experiments is mostly generated by the transition of excited nitrogen. The peak concentration of O₂ (A¹), O₂ (B¹) and O₂ (A³ ∑⁺u) is not low compared to the excited nitrogen molecules. These particles energy is relatively low and the transition spectral is longer. The spectrometer does not capture the oxygen emission spectrum. And the peak concentration of O particles is small, so the transition emission spectrum is weak. The calculation results of the stabled model can well explain the emission spectrum data.

  7. [A new measurement method of time-resolved spectrum].

    Science.gov (United States)

    Shi, Zhi-gang; Huang, Shi-hua; Liang, Chun-jun; Lei, Quan-sheng

    2007-02-01

    A new method for measuring time-resolved spectrum (TRS) is brought forward. Programming with assemble language controlled the micro-control-processor (AT89C51), and a kind of peripheral circuit constituted the drive circuit, which drived the stepping motor to run the monochromator. So the light of different kinds of expected wavelength could be obtained. The optical signal was transformed to electrical signal by optical-to-electrical transform with the help of photomultiplier tube (Hamamatsu 1P28). The electrical signal of spectrum data was transmitted to the oscillograph. Connecting the two serial interfaces of RS232 between the oscillograph and computer, the electrical signal of spectrum data could be transmitted to computer for programming to draw the attenuation curve and time-resolved spectrum (TRS) of the swatch. The method for measuring time-resolved spectrum (TRS) features parallel measurement in time scale but serial measurement in wavelength scale. Time-resolved spectrum (TRS) and integrated emission spectrum of Tb3+ in swatch Tb(o-BBA)3 phen were measured using this method. Compared with the real time-resolved spectrum (TRS). It was validated to be feasible, credible and convenient. The 3D spectra of fluorescence intensity-wavelength-time, and the integrated spectrum of the swatch Tb(o-BBA)3 phen are given.

  8. Investigation on method of estimating the excitation spectrum of vibration source

    International Nuclear Information System (INIS)

    Zhang Kun; Sun Lei; Lin Song

    2010-01-01

    In practical engineer area, it is hard to obtain the excitation spectrum of the auxiliary machines of nuclear reactor through direct measurement. To solve this problem, the general method of estimating the excitation spectrum of vibration source through indirect measurement is proposed. First, the dynamic transfer matrix between the virtual excitation points and the measure points is obtained through experiment. The matrix combined with the response spectrum at the measure points under practical work condition can be used to calculate the excitation spectrum acts on the virtual excitation points. Then a simplified method is proposed which is based on the assumption that the vibration machine can be regarded as rigid body. The method treats the centroid as the excitation point and the dynamic transfer matrix is derived by using the sub structure mobility synthesis method. Thus, the excitation spectrum can be obtained by the inverse of the transfer matrix combined with the response spectrum at the measure points. Based on the above method, a computing example is carried out to estimate the excitation spectrum acts on the centroid of a electrical pump. By comparing the input excitation and the estimated excitation, the reliability of this method is verified. (authors)

  9. Measuring of heat transfer coefficient

    DEFF Research Database (Denmark)

    Henningsen, Poul; Lindegren, Maria

    Subtask 3.4 Measuring of heat transfer coefficient Subtask 3.4.1 Design and setting up of tests to measure heat transfer coefficient Objective: Complementary testing methods together with the relevant experimental equipment are to be designed by the two partners involved in order to measure...... the heat transfer coefficient for a wide range of interface conditions in hot and warm forging processes. Subtask 3.4.2 Measurement of heat transfer coefficient The objective of subtask 3.4.2 is to determine heat transfer values for different interface conditions reflecting those typically operating in hot...

  10. A Novel Wireless Power Transfer-Based Weighed Clustering Cooperative Spectrum Sensing Method for Cognitive Sensor Networks.

    Science.gov (United States)

    Liu, Xin

    2015-10-30

    In a cognitive sensor network (CSN), the wastage of sensing time and energy is a challenge to cooperative spectrum sensing, when the number of cooperative cognitive nodes (CNs) becomes very large. In this paper, a novel wireless power transfer (WPT)-based weighed clustering cooperative spectrum sensing model is proposed, which divides all the CNs into several clusters, and then selects the most favorable CNs as the cluster heads and allows the common CNs to transfer the received radio frequency (RF) energy of the primary node (PN) to the cluster heads, in order to supply the electrical energy needed for sensing and cooperation. A joint resource optimization is formulated to maximize the spectrum access probability of the CSN, through jointly allocating sensing time and clustering number. According to the resource optimization results, a clustering algorithm is proposed. The simulation results have shown that compared to the traditional model, the cluster heads of the proposed model can achieve more transmission power and there exists optimal sensing time and clustering number to maximize the spectrum access probability.

  11. A Novel Wireless Power Transfer-Based Weighed Clustering Cooperative Spectrum Sensing Method for Cognitive Sensor Networks

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2015-10-01

    Full Text Available In a cognitive sensor network (CSN, the wastage of sensing time and energy is a challenge to cooperative spectrum sensing, when the number of cooperative cognitive nodes (CNs becomes very large. In this paper, a novel wireless power transfer (WPT-based weighed clustering cooperative spectrum sensing model is proposed, which divides all the CNs into several clusters, and then selects the most favorable CNs as the cluster heads and allows the common CNs to transfer the received radio frequency (RF energy of the primary node (PN to the cluster heads, in order to supply the electrical energy needed for sensing and cooperation. A joint resource optimization is formulated to maximize the spectrum access probability of the CSN, through jointly allocating sensing time and clustering number. According to the resource optimization results, a clustering algorithm is proposed. The simulation results have shown that compared to the traditional model, the cluster heads of the proposed model can achieve more transmission power and there exists optimal sensing time and clustering number to maximize the spectrum access probability.

  12. Comparison of modulation transfer function, noise power spectrum, and sensitometric measurements of x-ray screen-film systems made in two different laboratories

    International Nuclear Information System (INIS)

    Sandrik, J.M.; Jennings, R.J.; Wagner, R.F.

    1980-01-01

    A project to develop standardization in the measurement of fundamental characteristics of screen-film systems is described. This project is a comparison of measurements on the same film samples performed by both the Kurt Rossmann Laboratories for Radiologic Image Research at the University of Chicago and by the Radiologic Imaging Section in the Medical Physics Branch, Division of Electronic Products. For this comparison we are making three fundamental measurements that characterize the operation of the screen-film systems. One is sensitometry of the characteristic or H and D curve. The film darkening is studied as a function of x-ray exposure to the screen-film system. This provides information on the speed and contrast of the system and it is also used in the determination of the MTF. The second measurement is the spatial frequency response or the MTF. For this measurement the screen-film system is exposed through a slit about 10 microns wide. This provides information on the fidelity with which contrast in the object is transferred to the image and information on the resolution of the image receptor. The third measure is the noise power or Wiener spectrum. In this case the film is exposed to a uniform x-ray field and the image provides information on the noise content of the receptor as a function of spatial frequency so that the effect of noise on the signal can be assessed

  13. Measurements of radio frequent cavity volt ages by X-ray spectrum measurements

    Directory of Open Access Journals (Sweden)

    Toprek Dragan

    2005-01-01

    Full Text Available This paper deals with X-ray spectrum measurement as a method for the measurement of radio frequent cavity voltage and the theory of X-ray spectrum calculation. Experimental results at 72 MHz for three different values of the radio frequent power of ACCEL K250 super conducting cyclotron are being presented.

  14. Activation method for measurement of neutron spectrum parameters

    International Nuclear Information System (INIS)

    Efimov, B.V.; Demidov, A.M.; Ionov, V.S.; Konjaev, S.I.; Marin, S.V.; Bryzgalov, V.I.

    2007-01-01

    Experimental researches of spectrum parameters of neutrons at nuclear installations RRC KI are submitted. The installations have different designs of the cores, reflector, parameters and types of fuel elements. Measurements were carried out with use of the technique developed in RRC KI for irradiation resonance detectors UKD. The arrangement of detectors in the cores ensured possibility of measurement of neutron spectra with distinguished values of parameters. The spectrum parameters which are introduced by parametrical representation of a neutrons spectrum in the form corresponding to formalism Westcott. On experimental data were determinate absolute values of density neutron flux (DNF) in thermal and epithermal area of a spectrum (F t , f epi ), empirical dependence of temperature of neutron gas (Tn) on parameter of a rigidity of a spectrum (z), density neutron flux in transitional energy area of the spectrum. Dependences of spectral indexes of nuclides (UDy/UX), included in UKD, from a rigidity z and-or temperatures of neutron gas Tn are obtained.B Tools of mathematical processing of results are used for activation data and estimation of parameters of a spectrum (F t , f epi , z, Tn, UDy/UX). In the paper are presented some results of researches of neutron spectrum parameters of the nuclear installations (Authors)

  15. Development and application of programs to measure modulation transfer function, noise power spectrum and detective quantum efficiency.

    Science.gov (United States)

    Padgett, R; Kotre, C J

    2005-01-01

    This project aimed to produce programs to calculate the modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) of digital X-ray systems, given a suitable digital image. The MTF was calculated using the edge technique and the NPS was calculated from a flat field image. Both programs require a suitably edited DICOM image as input. The DQE was then calculated from the output of MTF and NPS programs. This required data external to the DQE program to estimate the number of quanta per mm2 in the beam which formed the NPS image. All three programs run independent of each other on a PC and require no special software to be installed. Results for MTF, NPS and DQE for a Philips AC3 CR system are presented. In addition, the results for MTF from a Siemens Duo CT scanner with a specially designed PTFE edge are also shown.

  16. Quantifying creativity: can measures span the spectrum?

    Science.gov (United States)

    Simonton, Dean Keith

    2012-03-01

    Because the cognitive neuroscientists have become increasingly interested in the phenomenon of creativity, the issue arises of how creativity is to be optimally measured. Unlike intelligence, which can be assessed across the full range of intellectual ability creativity measures tend to concentrate on different sections of the overall spectrum. After first defining creativity in terms of the three criteria of novelty, usefulness, and surprise, this article provides an overview of the available measures. Not only do these instruments vary according to whether they focus on the creative process, person, or product, but they differ regarding whether they tap into "little-c" versus "Big-C" creativity; only productivity and eminence measures reach into genius-level manifestations of the phenomenon. The article closes by discussing whether various alternative assessment techniques can be integrated into a single measure that quantifies creativity across the full spectrum.

  17. Fast neutron spectrum measurement in the JMTR

    International Nuclear Information System (INIS)

    Sakurai, K.; Mizuho, M.

    1980-01-01

    Fast neutron spectrum measurement at positions of K-10 (fuel region), J-11 (first beryllium reflector region) and I-12 (second beryllium reflector region) in the JMTRC has been performed with the threshold detectors such as 107 Ag(n,n')sup(107m)Ag, 103 Rh(n,n')sup(103m)Rh, 115 In(n,n')sup(115m)In and 238 U(n,f)F.P. above 0.1 MeV energy region. The activity data have been analyzed by the unfolding code SAND-II using ANISN spectrum for initial spectrum. An effective cross section of 54 Fe(n,p) 54 Mn is calculated with Fabry's cross section data and SAND-II spectrum for K-10, J-11 and I-12. They are 76.7 mb, 69.0 mb and 68.2 mb for K-10, J-11 and I-12 respectively. These values agree with the effective cross sections (calculated by Fabry's cross section data and ANISN spectrum) within +-6%

  18. Implementation of 252Cf-source-driven power spectrum density measurement system

    International Nuclear Information System (INIS)

    Ren Yong; Wei Biao; Feng Peng; Li Jiansheng; Ye Cenming

    2012-01-01

    The principle of 252 Cf-source-driven power spectrum density measurement method is introduced. A measurement system and platform is realized accordingly, which is a combination of hardware and software, for measuring nuclear parameters. The detection method of neutron pulses based on an ultra-high-speed data acquisition card (three channels, 1 GHz sampling rate, 1 ns synchronization) is described, and the data processing process and the power spectrum density algorithm on PC are designed. This 252 Cf-source-driven power spectrum density measurement system can effectively obtain the nuclear tag parameters of nuclear random processes, such as correlation function and power spectrum density. (authors)

  19. The Atacama Cosmology Telescope: A Measurement of the Primordial Power Spectrum

    Science.gov (United States)

    Hlozek, Renee; Dunkley, Joanna; Addison, Graeme; Appel, John William; Bond, J. Richard; Carvalho, C. Sofia; Das, Sudeep; Devlin, Mark J.; Duenner, Rolando; Essinger-Hileman, Thomas; hide

    2011-01-01

    We present constraints on the primordial power spectrum of adiabatic fluctuations using data from the 2008 Southern Survey of the Atacama Cosmology Telescope (ACT). The angular resolution of ACT provides sensitivity to scales beyond l = 1000 for resolution of multiple peaks in the primordial temperature power spectrum, which enables us to probe the primordial power spectrum of adiabatic scalar perturbations with wavenumbers up to k approx. = 0.2 Mp/c. We find no evidence for deviation from power-law fluctuations over two decades in scale. Matter fluctuations inferred from the primordial temperature power spectrum evolve over cosmic time and can be used to predict the matter power spectrum at late times; we illustrate the overlap of the matter power inferred from CMB measurements (which probe the power spectrum in thc linear regime) with existing probes of galaxy clustering, cluster abundances and weak lensing constraints on the primordial power. This highlights the range of scales probed by current measurement.s of the matter power spectrum.

  20. Evolution of the Deep-space Galactic Cosmic Ray Lineal Energy Transfer Spectrum through Tissue Equivalent Plastic

    Science.gov (United States)

    Case, A. W.; Kasper, J. C.; Spence, H. E.; Golightly, M. J.; Schwadron, N. A.; Mazur, J. E.; Blake, J. B.; Looper, M. D.; Townsend, L.; Zeitlin, C. J.

    2011-12-01

    The Cosmic Ray Telescope for the Effects of Radiation is an energetic particle telescope that resides on the Lunar Reconnaissance Orbiter spacecraft, currently in a 50 km circular lunar polar orbit. The telescope consists of 6 silicon semi-conductor detectors placed in pairs that surround two pieces of Tissue Equivalent Plastic (TEP), which serve to absorb energy from particles as they transit through the instrument. Particles with energies greater than 12 MeV/nucleon can penetrate the outermost shield and be measured by the instrument. The primary measurement made by the instrument is of the Linear Energy Transfer (LET) of energetic particles as they transit through the telescope. CRaTER measures the LET spectrum with unprecedented energy resolution and has done so during a period of historically low solar activity that led to record high intensities of Galactic Cosmic Rays (GCR). These LET spectra are used to study changes in the properties of the incoming particles, and to make detailed measurements of the radiation doses human explorers will experience in deep space on missions to the moon, to asteroids, or to Mars. We present LET spectra accumulated during 2009 and 2010. We show how the LET spectrum evolves through the instrument as the GCR interact with the TEP. Due to the importance of these measurements for human effects, our extensive absolute calibration procedures are presented. Of particular note is a significant reduction in the flux of particles with LET greater than 10 keV/um for detectors that lie deeper within the telescope stack, due to the attenuation of high LET particles within the TEP. By measuring this attenuation we can estimate the depth in human tissue where the highest LET particles that are most likely to cause genetic damage pose the greatest threat to humans in space.

  1. THE ATACAMA COSMOLOGY TELESCOPE: A MEASUREMENT OF THE PRIMORDIAL POWER SPECTRUM

    Energy Technology Data Exchange (ETDEWEB)

    Hlozek, Renee; Dunkley, Joanna; Addison, Graeme [Department of Astrophysics, Oxford University, Oxford OX1 3RH (United Kingdom); Appel, John William; Das, Sudeep; Essinger-Hileman, Thomas; Fowler, Joseph W.; Hajian, Amir; Hincks, Adam D. [Joseph Henry Laboratories of Physics, Jadwin Hall, Princeton University, Princeton, NJ 08544 (United States); Bond, J. Richard [Canadian Institute for Theoretical Astrophysics, University of Toronto, Toronto, ON M5S 3H8 (Canada); Carvalho, C. Sofia [IPFN, IST, Av. RoviscoPais, 1049-001Lisboa, Portugal and RCAAM, Academy of Athens, Soranou Efessiou 4, 11-527 Athens (Greece); Devlin, Mark J.; Klein, Jeff [Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104 (United States); Duenner, Rolando; Gallardo, Patricio [Departamento de Astronomia y Astrofisica, Facultad de Fisica, Pontificia Universidad Catolica de Chile, Casilla 306, Santiago 22 (Chile); Halpern, Mark; Hasselfield, Matthew [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC V6T 1Z4 (Canada); Hilton, Matt [School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, NG7 2RD (United Kingdom); Hughes, John P. [Department of Physics and Astronomy, Rutgers, The State University of New Jersey, Piscataway, NJ 08854-8019 (United States); Irwin, Kent D. [NIST Quantum Devices Group, 325 Broadway Mailcode 817.03, Boulder, CO 80305 (United States); and others

    2012-04-10

    We present constraints on the primordial power spectrum of adiabatic fluctuations using data from the 2008 Southern Survey of the Atacama Cosmology Telescope (ACT) in combination with measurements from the Wilkinson Microwave Anisotropy Probe and a prior on the Hubble constant. The angular resolution of ACT provides sensitivity to scales beyond l = 1000 for resolution of multiple peaks in the primordial temperature power spectrum, which enables us to probe the primordial power spectrum of adiabatic scalar perturbations with wavenumbers up to k {approx_equal} 0.2 Mpc{sup -1}. We find no evidence for deviation from power-law fluctuations over two decades in scale. Matter fluctuations inferred from the primordial temperature power spectrum evolve over cosmic time and can be used to predict the matter power spectrum at late times; we illustrate the overlap of the matter power inferred from cosmic microwave background measurements (which probe the power spectrum in the linear regime) with existing probes of galaxy clustering, cluster abundances, and weak-lensing constraints on the primordial power. This highlights the range of scales probed by current measurements of the matter power spectrum.

  2. Neutron spectrum measurement using rise-time discrimination method

    International Nuclear Information System (INIS)

    Luo Zhiping; Suzuki, C.; Kosako, T.; Ma Jizeng

    2009-01-01

    PSD method can be used to measure the fast neutron spectrum in n/γ mixed field. A set of assemblies for measuring the pulse height distribution of neutrons is built up,based on a large volume NE213 liquid scintillator and standard NIM circuits,through the rise-time discrimination method. After that,the response matrix is calculated using Monte Carlo method. The energy calibration of the pulse height distribution is accomplished using 60 Co radioisotope. The neutron spectrum of the mono-energetic accelerator neutron source is achieved by unfolding process. Suggestions for further improvement of the system are presented at last. (authors)

  3. Application of real time spectrum measurement to radiation monitors

    International Nuclear Information System (INIS)

    Matsuno, K.; Watanabe, M.; Sakamaki, T.

    1996-01-01

    A multichannel analyzer (MCA) and two realtime spectrum monitoring methods have been developed for use in radiation monitors. The new MCA was designed to be installed at a local site as a component of a radiation monitor. The MCA repeats spectrum measurement at short intervals (Δt) and, after each measurement, transmits a spectrum datum to the operation console. The authors applied two methods to process Δt spectrum counts for each channel for longer time interval. One method of processing counts is the 'running average (RA) method'. The other method is the 'exponential smoothing (ES) method', which simulates RC rate meters by subtracting a fraction corresponding to the accumulated counts. Relative standard deviations for each channel can be made the same by selecting an appropriate value. The response with the 'ES' method is initially faster than that with the 'RA' method, but the 'RA' method allows a full response to be reached at a predictable time. (author)

  4. UMTS signal measurements with digital spectrum analysers

    International Nuclear Information System (INIS)

    Licitra, G.; Palazzuoli, D.; Ricci, A. S.; Silvi, A. M.

    2004-01-01

    The launch of the Universal Mobile Telecommunications System (UNITS), the most recent mobile telecommunications standard has imposed the requirement of updating measurement instrumentation and methodologies. In order to define the most reliable measurement procedure, which is aimed at assessing the exposure to electromagnetic fields, modern spectrum analysers' features for correct signal characterisation has been reviewed. (authors)

  5. Measuring transferring similarity via local information

    Science.gov (United States)

    Yin, Likang; Deng, Yong

    2018-05-01

    Recommender systems have developed along with the web science, and how to measure the similarity between users is crucial for processing collaborative filtering recommendation. Many efficient models have been proposed (i.g., the Pearson coefficient) to measure the direct correlation. However, the direct correlation measures are greatly affected by the sparsity of dataset. In other words, the direct correlation measures would present an inauthentic similarity if two users have a very few commonly selected objects. Transferring similarity overcomes this drawback by considering their common neighbors (i.e., the intermediates). Yet, the transferring similarity also has its drawback since it can only provide the interval of similarity. To break the limitations, we propose the Belief Transferring Similarity (BTS) model. The contributions of BTS model are: (1) BTS model addresses the issue of the sparsity of dataset by considering the high-order similarity. (2) BTS model transforms uncertain interval to a certain state based on fuzzy systems theory. (3) BTS model is able to combine the transferring similarity of different intermediates using information fusion method. Finally, we compare BTS models with nine different link prediction methods in nine different networks, and we also illustrate the convergence property and efficiency of the BTS model.

  6. Measurement of 235U fission spectrum-averaged cross sections and neutron spectrum adjusted with the activation data

    International Nuclear Information System (INIS)

    Kobayashi, Katsuhei; Kobayashi, Tooru

    1992-01-01

    The 235 U fission spectrum-averaged cross sections for 13 threshold reactions were measured with the fission plate (27 cm in diameter and 1.1 cm thick) at the heavy water thermal neutron facility of the Kyoto University Reactor. The Monte Carlo code MCNP was applied to check the deviation from the 235 U fission neutron spectrum due to the room-scattered neutrons, and it was found that the resultant spectrum was close to that of 235 U fission neutrons. Supplementally, the relations to derive the absorbed dose rates with the fission plate were also given using the calculated neutron spectra and the neutron Kerma factors. Finally, the present values of the fission spectrum-averaged cross sections were employed to adjust the 235 U fission neutron spectrum with the NEUPAC code. The adjusted spectrum showed a good agreement with the Watt-type fission neutron spectrum. (author)

  7. Linearized spectrum correlation analysis for line emission measurements.

    Science.gov (United States)

    Nishizawa, T; Nornberg, M D; Den Hartog, D J; Sarff, J S

    2017-08-01

    A new spectral analysis method, Linearized Spectrum Correlation Analysis (LSCA), for charge exchange and passive ion Doppler spectroscopy is introduced to provide a means of measuring fast spectral line shape changes associated with ion-scale micro-instabilities. This analysis method is designed to resolve the fluctuations in the emission line shape from a stationary ion-scale wave. The method linearizes the fluctuations around a time-averaged line shape (e.g., Gaussian) and subdivides the spectral output channels into two sets to reduce contributions from uncorrelated fluctuations without averaging over the fast time dynamics. In principle, small fluctuations in the parameters used for a line shape model can be measured by evaluating the cross spectrum between different channel groupings to isolate a particular fluctuating quantity. High-frequency ion velocity measurements (100-200 kHz) were made by using this method. We also conducted simulations to compare LSCA with a moment analysis technique under a low photon count condition. Both experimental and synthetic measurements demonstrate the effectiveness of LSCA.

  8. Noninvasive hemoglobin measurement using dynamic spectrum

    Science.gov (United States)

    Yi, Xiaoqing; Li, Gang; Lin, Ling

    2017-08-01

    Spectroscopy methods for noninvasive hemoglobin (Hgb) measurement are interfered by individual difference and particular weak signal. In order to address these problems, we have put forward a series of improvement methods based on dynamic spectrum (DS), including instrument design, spectrum extraction algorithm, and modeling approach. The instrument adopts light sources composed of eight laser diodes with the wavelength range from 600 nm to 1100 nm and records photoplethysmography signals at eight wavelengths synchronously. In order to simplify the optical design, we modulate the light sources with orthogonal square waves and design the corresponding demodulation algorithm, instead of adopting a beam-splitting system. A newly designed algorithm named difference accumulation has been proved to be effective in improving the accuracy of dynamic spectrum extraction. 220 subjects are involved in the clinical experiment. An extreme learning machine calibration model between the DS data and the Hgb levels is established. Correlation coefficient and root-mean-square error of prediction sets are 0.8645 and 8.48 g/l, respectively. The results indicate that the Hgb level can be derived by this approach noninvasively with acceptable precision and accuracy. It is expected to achieve a clinic application in the future.

  9. Simultaneous wireless information and power transfer for spectrum sharing in cognitive radio communication systems

    KAUST Repository

    Benkhelifa, Fatma

    2016-07-26

    In this paper, we consider the simultaneous wireless information and power transfer for the spectrum sharing (SS) in cognitive radio (CR) systems with a multi-antenna energy harvesting (EH) primary receiver (PR). The PR uses the antenna switching (AS) technique that assigns a subset of the PR\\'s antennas to harvest the energy from the radio frequency (RF) signals sent by the secondary transmitter (ST), and assigns the rest of the PR\\'s antennas to decode the information data. In this context, the primary network allows the secondary network to use the spectrum as long as the interference induced by the secondary transmitter (ST)\\'s signals is beneficial for the energy harvesting process at the PR side. The objective of this work is to show that the spectrum sharing is beneficial for both the SR and PR sides and leads to a win-win situation. To illustrate the incentive of the spectrum sharing cognitive system, we evaluate the mutual outage probability (MOP) introduced in [1] which declares an outage event if the PR or the secondary receiver (SR) is in an outage. Through the simulation results, we show that the performance of our system in terms of the MOP is always better than the performance of the system in the absence of ST and improves as the ST-PR interference increases. © 2016 IEEE.

  10. Spectrum resolving power of hearing: measurements, baselines, and influence of maskers

    Directory of Open Access Journals (Sweden)

    Alexander Ya. Supin

    2011-06-01

    Full Text Available Contemporary methods of measurement of frequency tuning in the auditory system are reviewed. Most of them are based on the frequency-selective masking paradigm and require multi-point measurements (a number of masked thresholds should be measured to obtain a single frequency-tuning estimate. Therefore, they are rarely used for practical needs. As an alternative approach, frequency-selective properties of the auditory system may be investigated using probes with complex frequency spectrum patterns, in particular, rippled noise that is characterized by a spectrum with periodically alternating maxima and minima. The maximal ripple density discriminated by the auditory system is  a convenient measure of the spectrum resolving power (SRP. To find the highest resolvable ripple density, a phase-reversal test has been suggested. Using this technique, normal SRP, its dependence on probe center frequency, spectrum contrast, and probe level were measured. The results were not entirely predictable by frequency-tuning data obtained by masking methods. SRP is influenced by maskers, with on- and off-frequency maskers influencing SRP very differently. Dichotic separation of the probe and masker results in almost complete release of SRP from influence of maskers.

  11. A technique of measuring neutron spectrum

    International Nuclear Information System (INIS)

    Sarkar, P.K.; Kirthi, K.N.; Ganguly, A.K.

    1975-01-01

    Plastic scintillators have been used to measure fast neutron spectrum from various sources. Gamma background discrimination has been done by selecting thin scintillators and thereby achieving near 100% transmission of Compton-edge electrons. The measured distribution has been unfolded by using an iterative least square technique. This gives minimum variance and maximum likelihood estimate with error minimised. Smoothening of the observed distribution has been done by Fourier and time series analyses. The method developed is applicable in principle for the determination of spectra of high energy neutrons ranging from 1 MeV to 70 MeV and beyond. However, practical application of the method is limited by the non-availability of cross-section data for various neutron induced reactions with carbon and hydrogen present in the polymerised polystyrene scintillator. This procedure has been adopted in the present work for spectral determination up to 14 MeV neutrons using the published value of reaction and scattering cross-sections. The spectra of Po-Be, Pu-Be, Am-Be and Ra-Be arrived at agree well with the published spectra obtained by other methods. Spectrum from spontaneous fission of Cf-252 have also been measured and fitted to the expression N(E)=Esup(1/2)exp(-E/T). The fitted parameter T and spectral details agree well with those in published literature

  12. Measurement of heat transfer coefficient using termoanemometry methods

    Science.gov (United States)

    Dančová, P.; Sitek, P.; Vít, T.

    2014-03-01

    This work deals with a measurement of heat transfer from a heated flat plate on which a synthetic jet impacts perpendicularly. Measurement of a heat transfer coefficient (HTC) is carried out using the hot wire anemometry method with glue film probe Dantec 55M47. The paper brings also results of velocity profiles measurements and turbulence intensity calculations.

  13. Unfolding measurement of the atmospheric muon neutrino spectrum using IceCube

    Energy Technology Data Exchange (ETDEWEB)

    Boerner, Mathis; Ruhe, Tim; Meier, Maximilian; Schlunder, Philipp; Menne, Thorben; Fuchs, Tomasz [Dept. of Physics, Technical University of Dortmund, 44227 Dortmund (Germany); Collaboration: IceCube-Collaboration

    2016-07-01

    IceCube is a cubic kilometer neutrino observatory located at the geographic South Pole. With its huge volume, the detector is well suited for measurements of the atmospheric muon neutrino energy spectrum. Over the last years, several unfolding analyses for single years were able to provide model independent measurements for the northern hemisphere in an energy region between 200 GeV and 3.2 PeV. In this talk, the extension of the analyses to four additional years of data is presented. With this significant enlargement of the data basis, it is possible to reanalyze the full northern hemisphere with smaller statistical errors. Moreover, the spectrum can be unfolded in several small zenith bands. Measurements of the energy spectrum for different zenith regions provide further information on the composition and the shape of the flux.

  14. Measurement of heat transfer coefficient using termoanemometry methods

    Directory of Open Access Journals (Sweden)

    Dančová P.

    2014-03-01

    Full Text Available This work deals with a measurement of heat transfer from a heated flat plate on which a synthetic jet impacts perpendicularly. Measurement of a heat transfer coefficient (HTC is carried out using the hot wire anemometry method with glue film probe Dantec 55M47. The paper brings also results of velocity profiles measurements and turbulence intensity calculations.

  15. [A Method to Reconstruct Surface Reflectance Spectrum from Multispectral Image Based on Canopy Radiation Transfer Model].

    Science.gov (United States)

    Zhao, Yong-guang; Ma, Ling-ling; Li, Chuan-rong; Zhu, Xiao-hua; Tang, Ling-li

    2015-07-01

    Due to the lack of enough spectral bands for multi-spectral sensor, it is difficult to reconstruct surface retlectance spectrum from finite spectral information acquired by multi-spectral instrument. Here, taking into full account of the heterogeneity of pixel from remote sensing image, a method is proposed to simulate hyperspectral data from multispectral data based on canopy radiation transfer model. This method first assumes the mixed pixels contain two types of land cover, i.e., vegetation and soil. The sensitive parameters of Soil-Leaf-Canopy (SLC) model and a soil ratio factor were retrieved from multi-spectral data based on Look-Up Table (LUT) technology. Then, by combined with a soil ratio factor, all the parameters were input into the SLC model to simulate the surface reflectance spectrum from 400 to 2 400 nm. Taking Landsat Enhanced Thematic Mapper Plus (ETM+) image as reference image, the surface reflectance spectrum was simulated. The simulated reflectance spectrum revealed different feature information of different surface types. To test the performance of this method, the simulated reflectance spectrum was convolved with the Landsat ETM + spectral response curves and Moderate Resolution Imaging Spectrometer (MODIS) spectral response curves to obtain the simulated Landsat ETM+ and MODIS image. Finally, the simulated Landsat ETM+ and MODIS images were compared with the observed Landsat ETM+ and MODIS images. The results generally showed high correction coefficients (Landsat: 0.90-0.99, MODIS: 0.74-0.85) between most simulated bands and observed bands and indicated that the simulated reflectance spectrum was well simulated and reliable.

  16. Inferring Weighted Directed Association Networks from Multivariate Time Series with the Small-Shuffle Symbolic Transfer Entropy Spectrum Method

    Directory of Open Access Journals (Sweden)

    Yanzhu Hu

    2016-09-01

    Full Text Available Complex network methodology is very useful for complex system exploration. However, the relationships among variables in complex systems are usually not clear. Therefore, inferring association networks among variables from their observed data has been a popular research topic. We propose a method, named small-shuffle symbolic transfer entropy spectrum (SSSTES, for inferring association networks from multivariate time series. The method can solve four problems for inferring association networks, i.e., strong correlation identification, correlation quantification, direction identification and temporal relation identification. The method can be divided into four layers. The first layer is the so-called data layer. Data input and processing are the things to do in this layer. In the second layer, we symbolize the model data, original data and shuffled data, from the previous layer and calculate circularly transfer entropy with different time lags for each pair of time series variables. Thirdly, we compose transfer entropy spectrums for pairwise time series with the previous layer’s output, a list of transfer entropy matrix. We also identify the correlation level between variables in this layer. In the last layer, we build a weighted adjacency matrix, the value of each entry representing the correlation level between pairwise variables, and then get the weighted directed association network. Three sets of numerical simulated data from a linear system, a nonlinear system and a coupled Rossler system are used to show how the proposed approach works. Finally, we apply SSSTES to a real industrial system and get a better result than with two other methods.

  17. New measurements of the spectrum of the cosmic microwave background

    International Nuclear Information System (INIS)

    Peterson, J.B.; Richards, P.L.; Bonomo, J.L.; Timusk, T.

    1984-06-01

    Accurate measurements of the spectrum of the cosmic microwave background (CMB) can provide useful tests of cosmological theories. The data set existing in 1982 has been summarized on a number of occasions and is shown. To first approximation the CMB is characterized by a single temperature and thus has a blackbody spectrum over the frequency range from 0.02 to 24 cm -1 . The error limits given for these experiments are dominated by systematic errors and are often very subjective. Consequently, it is not clear how to analyze the data set in a valid way. The general impression, however, is of a scatter in the high frequency data that is somewhat larger than would be expected from the given error limits. We have designed a new apparatus to measure the spectrum of the CMB in the frequency range from 3 to 10 cm -1 . 13 references, 5 figures

  18. Continuous Emission Spectrum Measurement for Electron Temperature Determination in Low-Temperature Collisional Plasmas

    International Nuclear Information System (INIS)

    Liu Qiuyan; Li Hong; Chen Zhipeng; Xie Jinlin; Liu Wandong

    2011-01-01

    Continuous emission spectrum measurement is applied for the inconvenient diagnostics of low-temperature collisional plasmas. According to the physical mechanism of continuous emission, a simplified model is presented to analyze the spectrum in low temperature plasma. The validity of this model is discussed in a wide range of discharge parameters, including electron temperature and ionization degree. Through the simplified model, the continuous emission spectrum in a collisional argon internal inductively coupled plasma is experimentally measured to determine the electron temperature distribution for different gas pressures and radio-frequency powers. The inverse Abel transform is also applied for a better spatially resoluted results. Meanwhile, the result of the continuous emission spectrum measurement is compared to that of the electrostatic double probes, which indicates the effectiveness of this method. (low temperature plasma)

  19. A method for measuring the energy spectrum of coincidence events in positron emission tomography.

    Science.gov (United States)

    Goertzen, Andrew L; Stout, David B; Thompson, Christopher J

    2010-01-21

    Positron emission tomography (PET) system energy response is typically characterized in singles detection mode, yet there are situations in which the energy spectrum of coincidence events might be different than the spectrum measured in singles mode. Examples include imaging with isotopes that emit a prompt gamma in coincidence with a positron emission, imaging with low activity in a LSO/LYSO-based cameras, in which the intrinsic activity is significant, and in high scatter situations where the two 511 keV photons have different scattering probabilities (i.e. off-center line source). The ability to accurately measure the energy spectrum of coincidence events could be used for validating simulation models, optimizing energy discriminator levels and examining scatter models and corrections. For many PET systems operating in coincidence mode, the only method available for estimating the energy spectrum is to step the lower and upper level discriminators (LLD and ULD). Simple measurement techniques such as using a narrow sliding energy window or stepping only the LLD will not yield a spectrum of coincidence events that is accurate for cases where there are different energy components contributing to the spectrum. In this work we propose a new method of measuring the energy spectrum of coincidence events in PET based on a linear combination of two sets of coincident count measurements: one made by stepping the LLD and one made by stepping the ULD. The method was tested using both Monte Carlo simulations of a Siemens microPET R4 camera and measured data acquired on a Siemens Inveon PET camera. The results show that our energy spectrum calculation method accurately measures the coincident energy spectra for cases including the beta/gamma spectrum of the (176)Lu intrinsic activity present in the LSO scintillator crystals, a (68)Ge source and an (124)I source (in which there are prompt gamma-rays emitted together with the positron).

  20. New layout of time resolved beam energy spectrum measurement for dragon-I

    International Nuclear Information System (INIS)

    Liao Shuqing; Zhang Kaizhi; Shi Jinshui

    2010-01-01

    A new layout of time resolved beam energy spectrum measurement is proposed for Dragon-I by a new method named RBS (rotating beams in solenoids). The basic theory of RBS and the new layout are presented and the measuring error is also discussed. The derived time resolved beam energy spectrum is discrete and is determined by measuring the beam's rotating angle and expanding width through a group of solenoids at the export of Dragon-I. (authors)

  1. Measuring light spectrum as a main indicator of artificial sources quality

    Directory of Open Access Journals (Sweden)

    Piotr Dąbrowski

    2015-05-01

    Full Text Available Objective: To compare different artificial light sources in different places where plant breeding is conduced. Methods: Measurements were conducted outdoor, in room, in greenhouse, under four panels with light emitting diodes, in phytotron, in dark room with various light sources and inside Sanyo versatile environmental chamber. The measurements were made by using SpectraPen SP100 (PSI, Czech Republic device. Results: Our result showed that spectrum measured outdoor during sunny day had only one peak at the wavelength of 485 nm (ca. 60000 relative units. On cloudy day, the trend of light spectrum curve was similar, but with lower values. At room conditions, the curve was more flat than outdoor. Under greenhouse conditions, the curve was similar to that measured outdoor. A few additional peaks on the curve appeared by adding high pressure sodium lamp. There were changes of curve under LED panels. Conclusions: It must be underlined that the most similar spectrum curve to daylight light has incandescent bulb and this light source should be preferred as support of daylight in greenhouses and as main source in phytotrons. Using high pressure sodium lamp in greenhouses as support of daylight cause increase in the red/far-red ratio and occurrence of a new peak on spectrum curve. The new possibilities are creating by LED panels with red and blue diodes.

  2. Evaluation of spectrum measurement devices for operational use

    CERN Document Server

    Devine, R T; Gray, D W; Seagraves, D T; Olsher, R H; Johnson, J P

    2002-01-01

    Several neutron spectrometers manufactured by Bubble Technology Industries (BTI) were tested and evaluated in a variety of neutron fields. Findings and conclusions are presented for the following BTI instruments: a modification of the Rotational Spectrometer (ROSPEC) that includes a thermal and epithermal capability, the Simple Scintillation Spectrometer that is used in conjunction with the ROSPEC to extend its high-energy range, and the MICROSPEC N-Probe which is capable of providing a crude spectrum over the energy range from thermal to 18 MeV. The main objective of these measurements was to determine the accuracy of both the energy spectrum and dose equivalent information generated by these devices. In addition, the dose response of the Wide-Energy Neutron Detection Instrument (WENDI-II) was measured in all neutron fields relative to a bare sup 2 sup 5 sup 2 Cf calibration. The performance of the WENDI-II rem meter was compared to the dose information generated by the neutron spectrometers. The instruments...

  3. Neutron spectrum measurement by TOF

    International Nuclear Information System (INIS)

    Aizawa, Otohiko

    1982-01-01

    The TOF experiments by using various facilities are described. The steady neutron spectra in light water which contains non-1/V absorbing materials were measured by the TOF method at a LINAC facility. The results were compared with the calculations based on the Koppel-Haywood model and two others. The leakage neutron spectra from a heavy-water assembly were measured and compared with model calculations. The time-dependent energy spectra in a small graphite assembly were measured. For this measurement, a chopper system was also used. The two-region calculation explains the spectrum just after the neutron burst. The time-dependent spectra in a small Be assembly and in an assembly of coolant-moderator containing hydrogen were also measured. The calculations based on various models are in progress. The TOF experiments at the reactor-chopper facility were carried out for measuring the total cross sections of crystalline moderators, the thermal neutron total cross section of high temperature beryllium, the thermal neutron total cross sections of granular lead and high temperature liquid lead, and the angle-dependent scattering spectra. A pseudo-chopper was designed and constructed. The spectra of the neutron field for medical use were measured by the chopper-TOF system. The thermal neutron total cross sections of Fe, Zr, Nb and Mg were measured, and the results were compared with the calculations by THRUSH and UNCLE-TOM codes. The random-trigger TOF experiments were made by using Cf-252. (Kato, T.)

  4. Experimental measurement of zero power reactor transfer function

    International Nuclear Information System (INIS)

    Liang Shuhong

    2011-01-01

    In order to study the zero power reactor (ZPR) transfer function, the ZPR transfer function expression was deduced with the point reactor kinetics equation, which was disturbed by reactivity input response. Based on the Fourier analysis for the input of triangular wave, the relation between the transfer function and reactivity was got. Validating research experiment was made on the DF-VI fast ZPR. After the disturbed reactivity was measured, the experimental value of the transfer function was got. According to the experimental value and the calculated value, the expression of the ZPR transfer function is proved, whereas the disturbed reactivity is got from the transfer function. (authors)

  5. The high-resolution extraterrestrial solar spectrum (QASUMEFTS determined from ground-based solar irradiance measurements

    Directory of Open Access Journals (Sweden)

    J. Gröbner

    2017-09-01

    Full Text Available A high-resolution extraterrestrial solar spectrum has been determined from ground-based measurements of direct solar spectral irradiance (SSI over the wavelength range from 300 to 500 nm using the Langley-plot technique. The measurements were obtained at the Izaña Atmospheric Research Centre from the Agencia Estatal de Meteorología, Tenerife, Spain, during the period 12 to 24 September 2016. This solar spectrum (QASUMEFTS was combined from medium-resolution (bandpass of 0.86 nm measurements of the QASUME (Quality Assurance of Spectral Ultraviolet Measurements in Europe spectroradiometer in the wavelength range from 300 to 500 nm and high-resolution measurements (0.025 nm from a Fourier transform spectroradiometer (FTS over the wavelength range from 305 to 380 nm. The Kitt Peak solar flux atlas was used to extend this high-resolution solar spectrum to 500 nm. The expanded uncertainties of this solar spectrum are 2 % between 310 and 500 nm and 4 % at 300 nm. The comparison of this solar spectrum with solar spectra measured in space (top of the atmosphere gave very good agreements in some cases, while in some other cases discrepancies of up to 5 % were observed. The QASUMEFTS solar spectrum represents a benchmark dataset with uncertainties lower than anything previously published. The metrological traceability of the measurements to the International System of Units (SI is assured by an unbroken chain of calibrations leading to the primary spectral irradiance standard of the Physikalisch-Technische Bundesanstalt in Germany.

  6. Neutron spectrum measurements from a neutron guide tube facility at the ETRR-1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maayouf, R M.A.; El-Sayed, L A.A.; El-Kady, A S.I. [Reactor and Neutron Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The present work deals with measurements of the neutron spectrum emitted from a neutron guide tube (NGT) recently installed at one of the ETRR-1 reactor horizontal channels designed to deliver thermal neutrons, free from fast neutrons and gamma ray background, to a fourier reverse-time-of-flight (RTOF) diffractometer. The measurements were performed using a {sup 6} Li glass scintillation detector combined with a multichannel analyzer set at channel width 4 M sec and installed at 3.4 m from a disc Fermi chopper. Also a theoretical model was specially developed for the neutron spectrum calculations. According to the model developed, the spectrum calculated was found to be in good agreement with the measured one. It was found, both from measurements and calculations, that the spectrum emitted from the NGT covers, after transmission through a fourier chopper, neutron wavelengths from 1-4 A adequate for neutron diffraction measurements at D values between 0.71-2.9 A respectively. 6 FIGS.

  7. Direct measurements of the spectrum of the near-millimeter cosmic background

    International Nuclear Information System (INIS)

    Richards, P.L.

    1980-01-01

    The spectrum of the cosmic background radiation peaks at 6 cm -1 and falls rapidly at higher frequencies. The experimental determination of this simple but important fact has had a long and troubled history. It remained in doubt long after the nature of the Rayleigh-Jeans region of the spectrum was firmly established. In this review the author describes the experimental difficulties which have plagued cosmic background measurements at and beyond the peak in the spectrum. A critical evaluation of the present status of the field is then given. (Auth.)

  8. A Simple Method of Spectrum Processing for β-ray Measurement without Pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jun Woo; Kim, Hee Reyoung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Radioactivity analysis of β-emitting radionuclide is important because of its dangerousness of overexposure. γ-ray has been measured by conventional detector such as NaI(Tl) or high purity germanium (HPGe) detector. But β-ray is hard to detect by those detectors because of its short range. Therefore, liquid scintillation counter (LSC) has been used to measure the radioactivity of pure beta emitter but there is huge problem of organic waste production, though LSC has high efficiency for detection of low energy β-ray. To solve this problem, characterization of β-ray measurement in a plastic scintillator was carried out in this study. There have been some studies about plastic scintillator to measure the β-rays without liquid scintillation method. Plastic scintillator has benefits for detection of β-ray because it has relative low effective atomic number. β-ray and γ-ray spectra in cylindrical plastic scintillator was analyzed and a method of separation of β-ray spectrum was suggested. A simple method of β-ray spectrum separation was suggested. The method was verified by chi-square method to estimate the difference between calculated and measured spectrum. This method was successfully applied by using disc source. For future works, practical radioactive source will be used to acquire the pulse height spectrum. The method can be used for measurement of pure β emitter without pretreatment if this method is verified for practical purpose.

  9. Classical and modern power spectrum estimation for tune measurement in CSNS RCS

    International Nuclear Information System (INIS)

    Yang Xiaoyu; Xu Taoguang; Fu Shinian; Zeng Lei; Bian Xiaojuan

    2013-01-01

    Precise measurement of betatron tune is required for good operating condition of CSNS RCS. The fractional part of betatron tune is important and it can be measured by analyzing the signals of beam position from the appointed BPM. Usually these signals are contaminated during the acquisition process, therefore several power spectrum methods are used to improve the frequency resolution. In this article classical and modern power spectrum methods are used. In order to compare their performance, the results of simulation data and IQT data from J-PARC RCS are discussed. It is shown that modern power spectrum estimation has better performance than the classical ones, though the calculation is more complex. (authors)

  10. Transfer function combinations

    KAUST Repository

    Zhou, Liang; Schott, Mathias; Hansen, Charles

    2012-01-01

    Direct volume rendering has been an active area of research for over two decades. Transfer function design remains a difficult task since current methods, such as traditional 1D and 2D transfer functions, are not always effective for all data sets. Various 1D or 2D transfer function spaces have been proposed to improve classification exploiting different aspects, such as using the gradient magnitude for boundary location and statistical, occlusion, or size metrics. In this paper, we present a novel transfer function method which can provide more specificity for data classification by combining different transfer function spaces. In this work, a 2D transfer function can be combined with 1D transfer functions which improve the classification. Specifically, we use the traditional 2D scalar/gradient magnitude, 2D statistical, and 2D occlusion spectrum transfer functions and combine these with occlusion and/or size-based transfer functions to provide better specificity. We demonstrate the usefulness of the new method by comparing to the following previous techniques: 2D gradient magnitude, 2D occlusion spectrum, 2D statistical transfer functions and 2D size based transfer functions. © 2012 Elsevier Ltd.

  11. Transfer function combinations

    KAUST Repository

    Zhou, Liang

    2012-10-01

    Direct volume rendering has been an active area of research for over two decades. Transfer function design remains a difficult task since current methods, such as traditional 1D and 2D transfer functions, are not always effective for all data sets. Various 1D or 2D transfer function spaces have been proposed to improve classification exploiting different aspects, such as using the gradient magnitude for boundary location and statistical, occlusion, or size metrics. In this paper, we present a novel transfer function method which can provide more specificity for data classification by combining different transfer function spaces. In this work, a 2D transfer function can be combined with 1D transfer functions which improve the classification. Specifically, we use the traditional 2D scalar/gradient magnitude, 2D statistical, and 2D occlusion spectrum transfer functions and combine these with occlusion and/or size-based transfer functions to provide better specificity. We demonstrate the usefulness of the new method by comparing to the following previous techniques: 2D gradient magnitude, 2D occlusion spectrum, 2D statistical transfer functions and 2D size based transfer functions. © 2012 Elsevier Ltd.

  12. Use of Advanced Magnetic Resonance Imaging Techniques in Neuromyelitis Optica Spectrum Disorder

    Science.gov (United States)

    Kremer, Stephane; Renard, Felix; Achard, Sophie; Lana-Peixoto, Marco A.; Palace, Jacqueline; Asgari, Nasrin; Klawiter, Eric C.; Tenembaum, Silvia N.; Banwell, Brenda; Greenberg, Benjamin M.; Bennett, Jeffrey L.; Levy, Michael; Villoslada, Pablo; Saiz, Albert; Fujihara, Kazuo; Chan, Koon Ho; Schippling, Sven; Paul, Friedemann; Kim, Ho Jin; de Seze, Jerome; Wuerfel, Jens T.

    2016-01-01

    Brain parenchymal lesions are frequently observed on conventional magnetic resonance imaging (MRI) scans of patients with neuromyelitis optica (NMO) spectrum disorder, but the specific morphological and temporal patterns distinguishing them unequivocally from lesions caused by other disorders have not been identified. This literature review summarizes the literature on advanced quantitative imaging measures reported for patients with NMO spectrum disorder, including proton MR spectroscopy, diffusion tensor imaging, magnetization transfer imaging, quantitative MR volumetry, and ultrahigh-field strength MRI. It was undertaken to consider the advanced MRI techniques used for patients with NMO by different specialists in the field. Although quantitative measures such as proton MR spectroscopy or magnetization transfer imaging have not reproducibly revealed diffuse brain injury, preliminary data from diffusion-weighted imaging and brain tissue volumetry indicate greater white matter than gray matter degradation. These findings could be confirmed by ultrahigh-field MRI. The use of nonconventional MRI techniques may further our understanding of the pathogenic processes in NMO spectrum disorders and may help us identify the distinct radiographic features corresponding to specific phenotypic manifestations of this disease. PMID:26010909

  13. Measurement of multinucleon transfer cross-sections

    Indian Academy of Sciences (India)

    Keywords. Ni(C, ), Fe(C, ), =C, C, B, B, Be, Be, Be, Be, Li, Li; = 60 MeV; measured reaction cross-section; elastic scattering angular distribution; deduced transfer probabilities and enhancement factors.

  14. Modulation Transfer Function of a Gaussian Beam Based on the Generalized Modified Atmospheric Spectrum

    Directory of Open Access Journals (Sweden)

    Chao Gao

    2016-01-01

    Full Text Available This paper investigates the modulation transfer function of a Gaussian beam propagating through a horizontal path in weak-fluctuation non-Kolmogorov turbulence. Mathematical expressions are obtained based on the generalized modified atmospheric spectrum, which includes the spectral power law value of non-Kolmogorov turbulence, the finite inner and outer scales of turbulence, and other optical parameters of the Gaussian beam. The numerical results indicate that the atmospheric turbulence would produce less negative effects on the wireless optical communication system with an increase in the inner scale of turbulence. Additionally, the increased outer scale of turbulence makes a Gaussian beam influenced more seriously by the atmospheric turbulence.

  15. Thermal striping heat transfer measurements in sodium AKB experiments

    International Nuclear Information System (INIS)

    Sheriff, N.; Sephton, K.P.; Gleave, C.

    1988-01-01

    Temperature fluctuations are produced in the sodium flow of fast reactors where hot and cold flow streams mix. A sodium experiment mounted on the Interatom facility AKB has been used to measure the heat transfer conditions in a flow stream with typical temperature fluctuations. The measurements were made at locations near to the leading edge of a plate, where in practice the most severe conditions are expected. With tests carried out over a wide range of flows good correlations of the heat transfer data with flow have been obtained. A simple theoretical model is proposed to explain the magnitude of the measured heat transfer coefficients, and the use of reasonable assumptions in the model produce good agreement with the experimental measurements

  16. Application of thermoluminescence dosimeter on the measurement of hard X-ray pulse energy spectrum

    International Nuclear Information System (INIS)

    Song Zhaohui; Wang Baohui; Wang Kuilu; Hei Dongwei; Sun Fengrong; Li Gang

    2003-01-01

    This paper introduces the application of thermoluminescence dosimeter (TLD) which composed by TLD-3500 reader and GR-100 M chips on the measurement of hard X-ray pulse energy spectrum. The idea using Filter Fluorescence Method (FFM) and TLD to measure hard X-ray pulse energy spectrum (from 10 keV to 100 keV) is discussed in details. Considering all the factors of the measuring surrounding, the measurement system of hard X-ray pulse has been devised. The calibration technique of absolute energy response of TLD is established. This method has been applied successfully on the radiation parameters measurement of the huge pulse radiation device-high-power pulser I. Hard X-ray pulse energy spectrum data of the pulser are acquired

  17. The measurement of prompt neutron spectrum in spontaneous fission of {sup 244}Cm

    Energy Technology Data Exchange (ETDEWEB)

    Batenkov, O.I.; Boykov, G.S.; Drapchinsky, L.V.; Majorov, M.Ju.; Trenkin, V.A. [V.G. Khlopin Radium Inst., Saint Petersburg (Russian Federation)

    1997-03-01

    Under the Program of Measurements of Prompt Fission Neutron Spectra of Minor Actinides for Transmutation Purposes the integral neutron spectrum in spontaneous fission of {sup 244}Cm has been measured by the time-of-flight method in the energy range of 0.1-15 MeV relative to the standard neutron spectrum in {sup 252}Cf spontaneous fission. Essential attention was paid to revealing of possible systematic errors. It is shown, that the {sup 244}Cm spectrum shape may be well described by using Mannhart evaluation with appropriate parameter of Maxwell temperature T{sub M} = 1.37 MeV. (author)

  18. Measurement of oxygen transfer from air into organic solvents

    DEFF Research Database (Denmark)

    Ramesh, Hemalata; Mayr, Torsten; Hobisch, Mathias

    2016-01-01

    biological reactions require the supply of oxygen, most normally from air. However, reliable on-line measurements of oxygen concentration in organic solvents (and hence oxygen transfer rates from air to the solvent) has to date proven impossible due limitations in the current analytical methods. Results...... applications). Subsequently, we measured the oxygen transfer rates from air into these organic solvents. Conclusion The measurement of oxygen transfer rates from air into organic solvents using the dynamic method was established using the solvent resistant optical sensor. The feasibility of online oxygen...... For the first time, we demonstrate on-line oxygen measurements in non-aqueous media using a novel optical sensor. The sensor was used to measure oxygen concentration in various organic solvents including toluene, THF, isooctane, DMF, heptane and hexane (which have all been shown suitable for several biological...

  19. Measurements of the energy spectrum of backscattered fast neutrons

    International Nuclear Information System (INIS)

    Segal, Y.

    1976-03-01

    Experimental measurements have been made of the energy spectra of neutrons transmitted through slabs of iron, lead and perspex for incident neutron energies of 0.5, 1.0, 1.5 and 1.8 MeV. The neutron energy measurements were made using a He-3 spectrometer. The dependence of the neutrons energy spectrum as a function of scattering thickness was determined. The neutrons source used was a 3MeV Van de Graaff accelerator with a tritium target using the H 3 (p,n) He 3 reaction. The results obtained by the investigator on energy dependence of transmitted neutrons as a function of thickness of scattering material were compared, where possible, with the results obtained by other workers. The comparisons indicated good agreement. The experiment's results are compared with MORSE Monte Carlo calculated values. It is worthwhile to note that direct comparison between measured cross section values and the recommended ones are very far from satisfactory. In almost all cases the calculated spectrum is harder than the experimental one, a situation common to the penetrating and the back-scattered flux

  20. Measurement of the transverse energy spectrum in proton-nucleon collisions

    International Nuclear Information System (INIS)

    Bettoni, D.

    1988-01-01

    The author describes a measurement of the transverse energy spectrum in proton-nucleon interactions carried out at the CERN SPS using the HELIOS spectrometer. The measurement is of particular interest in that it is performed in a rapidity region away from central rapidity, where experimental data is scarce. In this rapidity region very interesting physics is anticipated and the measurement of the proton-nucleon collisions is essential as a basis to understand the more complicated proton-nucleus and nucleus-nucleus interactions. Both these topics are part of the experimental program of HELIOS. The measurement was done using a deuterium target enclosed in an iron tube. The contribution to the transverse energy spectrum from the p-Fe events is discriminated against by reconstructing the primary interaction vertex using drift chamber information. The measured spectrum is corrected via Monte Carlo to deconvolute the effect of reinteractions. High spatial resolution and multi-track resolving power are achieved with the use of a cool gas, such that the electron characteristic energy is close to the thermal limit: this implies a small diffusion coefficient and a consequently good positional accuracy. Of vital importance are the low value of the drift velocity, the fast, differentiating electronics and a careful shaping of the electric field configuration to improve the isochrony of the drift collection. The author reports on the design and tests of drift chamber prototypes built along the above lines, with which a spatial accuracy of 0.06 mm and a double track resolution of 0.6 mm were measured. He also describes the final drift chamber system and its operation in HELIOS

  1. Mass transfer measurements in foams

    International Nuclear Information System (INIS)

    Leblond, J.G.; Fournel, B.

    2004-01-01

    Full text of publication follows:This study participates to the elaboration of a method for decontamination of the inside surfaces of steel structures (pipes, tanks,...). The solution which has been chosen is to attack the surface of the structure by a dipping solution. In order to reduce the quantity of product to be recovered and treated at the end of the cleaning process, the active solution will be introduced as a foam. During its free or forced drainage the foam supplies an active liquid film along the structure surfaces. It was important to know if the transfers of the dipping liquid inside the foam and between foam and wall film are sufficient to allow a correct supplying of the active liquid at the wall and a correct dragging of the dipped products. The objective of this work is to develop a numerical model which simulates the various transfers. However such a modeling cannot be performed without a thorough knowledge of the different transfer parameters in the foam and in the film. The following study has been performed on a model foam (foaming water + air) held in a smooth vertical glass pipe and submitted to a forced drainage by the foaming water (water + surfactants). The liquid transfer involves the dispersion of the drainage liquid inside the foam and the transfer between the foam and the liquid film flowing down at the wall. The different transfers has been analyzed by NMR using a PFGSE-NMR sequence, which allows to determine the propagator, i.e., the probability density of the liquid particle displacements during a given time interval Δt, along a selected direction. This study allowed to measure, firstly, the mean liquid and the liquid dispersion in the foam along the vertical and horizontal direction, and secondly, the vertical mean velocity in the parietal liquid film. (authors)

  2. A measurement of the low frequency spectrum of the cosmic microwave background radiation

    International Nuclear Information System (INIS)

    Levin, S.M.

    1987-04-01

    As part of a larger effort to measure the spectrum of the Cosmic Background Radiation (CBR) at low frequencies, the intensity of the CBR has been measured at a frequency of 1.410 GHz. The measurement was made by comparing the power received from the sky with the power received from a specially designed cooled calibration target with known properties. Sources of radiation other than the CBR were then identified and subtracted to calculate the antenna temperature of the CBR at 1.410 GHz. The instrument used to measure the CBR was a total-power microwave radiometer with a 25 MHz bandwidth centered at 1.410 GHz. The radiometer had a noise temperature of 80 K, and sufficient data were taken that radiometer noise did not contribute significantly to the total measurement error. The sources of error were predominantly systematic in nature, and the largest error was due to uncertainty in the reflection characteristics of the cold-load calibrator. Identification and subtraction of signals from the Galaxy (0.7 K) and the Earth's atmosphere (0.8 K) were also significant parts of the data reduction and error analysis. The brightness temperature of the Cosmic Background Radiation at 1.410 GHz is 222. +- 0.55 Kelvin. The spectrum of the CBR, as determined by this measurement and other published results, is consistent with a blackbody spectrum of temperature 2.741 +- 0.016. Constraints on the amount by which the CBR spectrum deviates from Planck spectrum are used to place limits on energy releases early in the history of the universe. 55 refs., 25 figs., 8 tabs

  3. Non intrusive measurement of the convective heat transfer coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Rebay, M.; Mebarki, G.; Padet, J. [Reims Univ., Reims (France). Faculty of Science, GRESPI Thermomechanical Lab; Arfaoui, A. [Reims Univ., Reims (France). Faculty of Science, GRESPI Thermomechanical Lab; Tunis Univ., Tunis (Tunisia). Faculty of Science, EL MANAR, LETTM; Maad, B.R. [Tunis Univ., Tunis (Tunisia). Faculty of Science, EL MANAR, LETTM

    2010-07-01

    The efficiency of cooling methods in thermal systems such as radiators and heat exchangers must be improved in order to enhance performance. The evaluation of the heat transfer coefficients between a solid and a fluid is necessary for the control and the dimensioning of thermal systems. In this study, the pulsed photothermal method was used to measure the convective heat transfer coefficient on a solid-fluid interface, notably between an air flow and a heated slab mounted on a PVC flat plate. This configuration simulated the electronic air-cooling inside enclosures and racks. The influence of the deflector's inclination angle on the enhancement of heat transfer was investigated using 2 newly developed identification models. The first model was based on a constant heat transfer coefficient during the pulsed experiment, while the second, improved model was based on a variable heat transfer coefficient. The heat transfer coefficient was deduced from the evolution of the transient temperature induced by a sudden deposit of a luminous energy on the front face of the slab. Temperature evolutions were derived by infrared thermography, a camera for cartography and a detector for precise measurement in specific locations. The results show the improvement of measurement accuracies when using a model that considers the temporal evolution of the convective heat transfer coefficient. The deflection of air flow on the upper surface of the heated slab demonstrated better cooling of the slab by the deflection of air flow. 11 refs., 1 tab., 8 figs.

  4. A generalized self-similar spectrum for decaying homogeneous and isotropic turbulence

    Science.gov (United States)

    Yang, Pingfan; Pumir, Alain; Xu, Haitao

    2017-11-01

    The spectrum of turbulence in dissipative and inertial range can be described by the celebrated Kolmogorov theory. However, there is no general solution of the spectrum in the large scales, especially for statistically unsteady turbulent flows. Here we propose a generalized self-similar form that contains two length-scales, the integral scale and the Kolmogorov scale, for decaying homogeneous and isotropic turbulence. With the help of the local spectral energy transfer hypothesis by Pao (Phys. Fluids, 1965), we derive and solve for the explicit form of the energy spectrum and the energy transfer function, from which the second- and third-order velocity structure functions can also be obtained. We check and verify our assumptions by direct numerical simulations (DNS), and our solutions of the velocity structure functions compare well with hot-wire measurements of high-Reynolds number wind-tunnel turbulence. Financial supports from NSFC under Grant Number 11672157, from the Alexander von Humboldt Foundation, and from the MPG are gratefully acknowledged.

  5. Measurement of the ν _{μ } energy spectrum with IceCube-79

    Science.gov (United States)

    Aartsen, M. G.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Al Samarai, I.; Altmann, D.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Archinger, M.; Argüelles, C.; Auffenberg, J.; Axani, S.; Bagherpour, H.; Bai, X.; Barwick, S. W.; Baum, V.; Bay, R.; Beatty, J. J.; Becker Tjus, J.; Becker, K.-H.; BenZvi, S.; Berley, D.; Bernardini, E.; Besson, D. Z.; Binder, G.; Bindig, D.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Bos, F.; Bose, D.; Böser, S.; Botner, O.; Bradascio, F.; Braun, J.; Brayeur, L.; Bretz, H.-P.; Bron, S.; Burgman, A.; Carver, T.; Casier, M.; Cheung, E.; Chirkin, D.; Christov, A.; Clark, K.; Classen, L.; Coenders, S.; Collin, G. H.; Conrad, J. M.; Cowen, D. F.; Cross, R.; Day, M.; de André, J. P. A. M.; De Clercq, C.; del Pino Rosendo, E.; Dembinski, H.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; DeYoung, T.; Díaz-Vélez, J. C.; di Lorenzo, V.; Dujmovic, H.; Dumm, J. P.; Dunkman, M.; Eberhardt, B.; Ehrhardt, T.; Eichmann, B.; Eller, P.; Euler, S.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Feintzeig, J.; Felde, J.; Filimonov, K.; Finley, C.; Flis, S.; Fösig, C.-C.; Franckowiak, A.; Friedman, E.; Fuchs, T.; Gaisser, T. K.; Gallagher, J.; Gerhardt, L.; Ghorbani, K.; Giang, W.; Gladstone, L.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Haack, C.; Hallgren, A.; Halzen, F.; Hansen, E.; Hansmann, T.; Hanson, K.; Hebecker, D.; Heereman, D.; Helbing, K.; Hellauer, R.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Hoshina, K.; Huang, F.; Huber, M.; Hultqvist, K.; In, S.; Ishihara, A.; Jacobi, E.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Kang, W.; Kappes, A.; Karg, T.; Karle, A.; Katz, U.; Kauer, M.; Keivani, A.; Kelley, J. L.; Kheirandish, A.; Kim, J.; Kim, M.; Kintscher, T.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Kohnen, G.; Koirala, R.; Kolanoski, H.; Konietz, R.; Köpke, L.; Kopper, C.; Kopper, S.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Kroll, M.; Krückl, G.; Krüger, C.; Kunnen, J.; Kunwar, S.; Kurahashi, N.; Kuwabara, T.; Kyriacou, A.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Lennarz, D.; Lesiak-Bzdak, M.; Leuermann, M.; Lu, L.; Lünemann, J.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Mancina, S.; Maruyama, R.; Mase, K.; Maunu, R.; McNally, F.; Meagher, K.; Medici, M.; Meier, M.; Menne, T.; Merino, G.; Meures, T.; Miarecki, S.; Micallef, J.; Momenté, G.; Montaruli, T.; Moulai, M.; Nahnhauer, R.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Obertacke Pollmann, A.; Olivas, A.; O'Murchadha, A.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Peiffer, P.; Penek, Ö.; Pepper, J. A.; Pérez de los Heros, C.; Pieloth, D.; Pinat, E.; Price, P. B.; Przybylski, G. T.; Quinnan, M.; Raab, C.; Rädel, L.; Rameez, M.; Rawlins, K.; Reimann, R.; Relethford, B.; Relich, M.; Resconi, E.; Rhode, W.; Richman, M.; Riedel, B.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Sabbatini, L.; Sanchez Herrera, S. E.; Sandrock, A.; Sandroos, J.; Sarkar, S.; Satalecka, K.; Schlunder, P.; Schmidt, T.; Schoenen, S.; Schöneberg, S.; Schumacher, L.; Seckel, D.; Seunarine, S.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stachurska, J.; Stanev, T.; Stasik, A.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Ström, R.; Strotjohann, N. L.; Sullivan, G. W.; Sutherland, M.; Taavola, H.; Taboada, I.; Tatar, J.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tešić, G.; Tilav, S.; Toale, P. A.; Tobin, M. N.; Toscano, S.; Tosi, D.; Tselengidou, M.; Tung, C. F.; Turcati, A.; Unger, E.; Usner, M.; Vandenbroucke, J.; van Eijndhoven, N.; Vanheule, S.; van Rossem, M.; van Santen, J.; Vehring, M.; Voge, M.; Vogel, E.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandkowsky, N.; Waza, A.; Weaver, Ch.; Weiss, M. J.; Wendt, C.; Westerhoff, S.; Whelan, B. J.; Wickmann, S.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, T. R.; Woolsey, E.; Woschnagg, K.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Zoll, M.

    2017-10-01

    IceCube is a neutrino observatory deployed in the glacial ice at the geographic South Pole. The ν _μ energy unfolding described in this paper is based on data taken with IceCube in its 79-string configuration. A sample of muon neutrino charged-current interactions with a purity of 99.5% was selected by means of a multivariate classification process based on machine learning. The subsequent unfolding was performed using the software Truee. The resulting spectrum covers an E_ν -range of more than four orders of magnitude from 125 GeV to 3.2 PeV. Compared to the Honda atmospheric neutrino flux model, the energy spectrum shows an excess of more than 1.9 σ in four adjacent bins for neutrino energies E_ν ≥ 177.8 {TeV}. The obtained spectrum is fully compatible with previous measurements of the atmospheric neutrino flux and recent IceCube measurements of a flux of high-energy astrophysical neutrinos.

  6. Measurement of the νμ energy spectrum with IceCube-79

    International Nuclear Information System (INIS)

    Aartsen, M.G.; Hill, G.C.; Kyriacou, A.; Robertson, S.; Wallace, A.; Whelan, B.J.; Ackermann, M.; Bernardini, E.; Blot, S.; Bradascio, F.; Bretz, H.P.; Franckowiak, A.; Jacobi, E.; Karg, T.; Kintscher, T.; Kunwar, S.; Nahnhauer, R.; Satalecka, K.; Spiering, C.; Stachurska, J.; Stasik, A.; Strotjohann, N.L.; Terliuk, A.; Usner, M.; Santen, J. van; Adams, J.; Bagherpour, H.; Aguilar, J.A.; Ansseau, I.; Heereman, D.; Meagher, K.; Meures, T.; O'Murchadha, A.; Pinat, E.; Raab, C.; Ahlers, M.; Braun, J.; Chirkin, D.; Day, M.; Desiati, P.; Diaz-Velez, J.C.; Fahey, S.; Feintzeig, J.; Ghorbani, K.; Gladstone, L.; Griffith, Z.; Halzen, F.; Hanson, K.; Hoshina, K.; Jero, K.; Karle, A.; Kauer, M.; Kelley, J.L.; Kheirandish, A.; Krueger, C.; Mancina, S.; McNally, F.; Merino, G.; Sabbatini, L.; Tobin, M.N.; Tosi, D.; Vandenbroucke, J.; Van Rossem, M.; Wandkowsky, N.; Wendt, C.; Westerhoff, S.; Wille, L.; Xu, D.L.; Ahrens, M.; Bohm, C.; Dumm, J.P.; Finley, C.; Flis, S.; Hultqvist, K.; Walck, C.; Wolf, M.; Zoll, M.; Al Samarai, I.; Bron, S.; Carver, T.; Christov, A.; Montaruli, T.; Altmann, D.; Anton, G.; Gluesenkamp, T.; Katz, U.; Kittler, T.; Tselengidou, M.; Andeen, K.; Anderson, T.; Dunkman, M.; Eller, P.; Huang, F.; Keivani, A.; Lanfranchi, J.L.; Pankova, D.V.; Quinnan, M.; Tesic, G.; Weiss, M.J.; Archinger, M.; Baum, V.; Boeser, S.; Del Pino Rosendo, E.; Di Lorenzo, V.; Eberhardt, B.; Ehrhardt, T.; Foesig, C.C.; Koepke, L.; Krueckl, G.; Momente, G.; Peiffer, P.; Sandroos, J.; Steuer, A.; Wiebe, K.; Argueelles, C.; Axani, S.; Collin, G.H.; Conrad, J.M.; Jones, B.J.P.; Moulai, M.; Auffenberg, J.; Glauch, T.; Haack, C.; Hansmann, T.; Konietz, R.; Leuermann, M.; Penek, Oe.; Raedel, L.; Reimann, R.; Rongen, M.; Schoenen, S.; Schumacher, L.; Stettner, J.; Vehring, M.; Vogel, E.; Wallraff, M.; Waza, A.; Wickmann, S.; Wiebusch, C.H.; Bai, X.; Barwick, S.W.; Yodh, G.; Bay, R.; Filimonov, K.; Price, P.B.; Woschnagg, K.; Beatty, J.J.; Becker Tjus, J.; Bos, F.; Eichmann, B.; Kroll, M.; Schoeneberg, S.; Tenholt, F.; Becker, K.H.; Bindig, D.; Helbing, K.; Hickford, S.; Hoffmann, R.; Kopper, S.; Lauber, F.; Naumann, U.; Obertacke Pollmann, A.; Soldin, D.; BenZvi, S.; Cross, R.; Berley, D.; Blaufuss, E.; Cheung, E.; Felde, J.; Friedman, E.; Hellauer, R.; Hoffman, K.D.; Maunu, R.; Olivas, A.; Schmidt, T.; Song, M.; Sullivan, G.W.; Besson, D.Z.; Binder, G.; Gerhardt, L.; Klein, S.R.; Miarecki, S.; Palczewski, T.; Tatar, J.; Boerner, M.; Fuchs, T.; Meier, M.; Menne, T.; Pieloth, D.; Rhode, W.; Ruhe, T.; Sandrock, A.; Schlunder, P.

    2017-01-01

    IceCube is a neutrino observatory deployed in the glacial ice at the geographic South Pole. The ν μ energy unfolding described in this paper is based on data taken with IceCube in its 79-string configuration. A sample of muon neutrino charged-current interactions with a purity of 99.5% was selected by means of a multivariate classification process based on machine learning. The subsequent unfolding was performed using the software Truee. The resulting spectrum covers an E ν -range of more than four orders of magnitude from 125 GeV to 3.2 PeV. Compared to the Honda atmospheric neutrino flux model, the energy spectrum shows an excess of more than 1.9σ in four adjacent bins for neutrino energies E ν ≥ 177.8 TeV. The obtained spectrum is fully compatible with previous measurements of the atmospheric neutrino flux and recent IceCube measurements of a flux of high-energy astrophysical neutrinos. (orig.)

  7. Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers.

    Science.gov (United States)

    Koontz, Alicia M; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L; Cooper, Rory A

    2011-01-01

    This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.

  8. A spectrum standardization approach for laser-induced breakdown spectroscopy measurements

    Energy Technology Data Exchange (ETDEWEB)

    Wang Zhe, E-mail: zhewang@mail.tsinghua.edu.cn; Li Lizhi; West, Logan; Li Zheng, E-mail: lz-dte@tsinghua.edu.cn; Ni Weidou

    2012-02-15

    This paper follows and completes a previous presentation of a spectrum normalization method for laser-induced breakdown spectroscopy (LIBS) measurements by converting the experimentally recorded line intensity at varying operational conditions to the intensity that would be obtained under a 'standard state' condition, characterized by a standard plasma temperature, electron number density, and total number density of the interested species. At first, for each laser shot and corresponding spectrum, the line intensities of the interested species are converted to the intensity at a fixed plasma temperature and electron number density, but with varying total number density. Under this state, if the influence of changing plasma morphology is neglected, the sum of multiple spectral line intensities for the measured element is proportional to the total number density of the specific element. Therefore, the fluctuation of the total number density, or the variation of ablation mass, can be compensated for by applying the proportional relationship. The application of this method to Cu in 29 brass alloy samples, showed an improvement over the commonly applied normalization method with regard to measurement precision and accuracy. The average relative standard deviation (RSD) value, average value of the error bar, R{sup 2}, root mean square error of prediction (RMSEP), and average value of the maximum relative error were: 5.29%, 0.68%, 0.98, 2.72%, 16.97%, respectively, while the above parameter values for normalization with the whole spectrum area were: 8.61%, 1.37%, 0.95, 3.28%, 29.19%, respectively. - Highlights: Black-Right-Pointing-Pointer Intensity converted into an ideal standard plasma state for uncertainty reduction. Black-Right-Pointing-Pointer Ablated mass fluctuations compensated by variation of sum of multiple intensities. Black-Right-Pointing-Pointer A spectrum standardization model established. Black-Right-Pointing-Pointer Results in both uncertainty

  9. Measurement of the pulse night spectrum Cerenkov flashes in the atmosphere

    International Nuclear Information System (INIS)

    Schlemmer, G.

    1981-03-01

    The determination of the energy spectrum of Cosmic Rays is difficult because of the low particle density at high energies. Normally such observations would require detectors with large collecting areas and long measurement periods. However the difficulty can be overcome by measuring shower induced Cerenkov radiation, the photon density of which is proportional to the shower energy. The Cerenkov radiation measurements reported here were made using two photomultipliers connected to a coincidence counter unit. The shower energy was deduced from measurements of the height of the pulses observed at the multiplier output,which should be proportional to the number of Cerenkov photons arriving at the photocathode. In order to make meaningful statements about the shower energy the statistical response of the photomultiplier system had to be standardized. This calibration was carried out by illuminating the photomultiplier cathode with a pulsed LED of pulsewidth 5 ns. For different light intensities of the LED a pulse-height spectrum was taken at the multiplier output. In addition to the Cerenkov photons counted by the photomultipliers, there exists a strong constant background light intensity. This background can be eliminated by employing a coincidence amplifier with a resolution time of 10 ns. To reduce background induced accidental coincidences the apparatus was equipped with a variable trigger level. To test the apparatus the Cerenkov radiation induced by cosmic rays in a water basin and in the photomultiplier window itself was measured and compared to theoretical estimates. The agreement was good. The pulse height spectrum of atmospheric Cerenkov radiation was obtained at the Cosmic Ray Physics Laboratory at the Hafelekar Observatory near Innsbruck. The measurements obtained there allowed the exponnent $delta in the differential energy spectrum N(E) dE c.Esup(-$delta)dE of the primary Cosmic Radiation to be evaluated. The value of $delta in the energy range 2,5 x 10 14

  10. Continuous optical measurement system of hemolysis during a photosensitization reaction using absorption spectrum

    Science.gov (United States)

    Hamada, R.; Ogawa, E.; Arai, T.

    2018-02-01

    To investigate hemolysis phenomena during a photosensitization reaction with the reaction condition continuously and simultaneously for a safety assessment of hemolysis side effect, we constructed an optical system to measure blood sample absorption spectrum during the reaction. Hemolysis degree might be under estimated in general evaluation methods because there is a constant oxygen pressure assumption in spite of oxygen depression take place. By investigating hemoglobin oxidation and oxygen desorption dynamics obtained from the contribution of the visible absorption spectrum and multiple regression analysis, both the hemolysis phenomena and its oxygen environment might be obtained with time. A 664 nm wavelength laser beam for the reaction excitation and 475-650 nm light beam for measuring the absorbance spectrum were arranged perpendicularly crossing. A quartz glass cuvette with 1×10 mm in dimensions for the spectrum measurement was located at this crossing point. A red blood cells suspension medium was arranged with low hematocrit containing 30 μg/ml talaporfin sodium. This medium was irradiated up to 40 J/cm2 . The met-hemoglobin, oxygenatedhemoglobin, and deoxygenated-hemoglobin concentrations were calculated by a multiple regression analysis from the measured spectra. We confirmed the met-hemoglobin concentration increased and oxygen saturation decreased with the irradiation time, which seems to indicate the hemolysis progression and oxygen consumption, respectively. By using our measuring system, the hemolysis progression seems to be obtained with oxygen environment information.

  11. Sequential measurements of spectrum and dose for cosmic-ray neutrons on the ground

    International Nuclear Information System (INIS)

    Hirabayashi, N.; Nunomiya, T.; Suzuki, H.; Nakamura, T.

    2002-01-01

    The earth is continually bathed in high-energy particles that come from outside the solar system, known as galactic cosmic rays. When these particles penetrate the magnetic fields of the solar system and the Earth and reach the Earth's atmosphere, they collide with atomic nuclei in air and secondary cosmic rays of every kind. On the other hand, levels of accumulation of the semiconductor increase recently, and the soft error that the cosmic-ray neutrons cause has been regarded as questionable. There have been long-term measurements of cosmic-ray neutron fluence at several places in the world, but no systematic study on cosmic-ray neutron spectrum measurements. This study aimed to measure the cosmic-ray neutron spectrum and dose on the ground during the solar maximum period of 2000 to 2002. Measurements have been continuing in a cabin of Tohoku University Kawauchi campus, by using five multi-moderator spectrometers (Bonner sphere), 12.7 cm diam by 12.7 cm long NE213 scintillator, and rem counter. The Bonner sphere uses a 5.08 cm diam spherical 3 He gas proportional counter and the rem counter uses a 12.7 cm diam 3 He gas counter. The neutron spectra were obtained by unfolding from the count rates measured with the Bonner sphere using the SAND code and the pulse height spectra measured with the NE213 scintillator using the FORIST code . The cosmic- ray neutron spectrum and ambient dose rates have been measured sequentially from April 2001. Furthermore, the correlation between ambient dose rate and the atmospheric pressure was investigated with a barometer. We are also very much interested in the variation of neutron spectrum following big solar flares. From the sequential measurements, we found that the cosmic-ray neutron spectrum has two peaks at around 1 MeV and at around 100 MeV, and the higher energy peak increases with a big solar flare

  12. Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Day-Lewis, Frederick; Singha, Kamini; Haggerty, Roy; Johnson, Tim; Binley, Andrew; Lane, John

    2014-01-16

    Mass transfer affects contaminant transport and is thought to control the efficiency of aquifer remediation at a number of sites within the Department of Energy (DOE) complex. An improved understanding of mass transfer is critical to meeting the enormous scientific and engineering challenges currently facing DOE. Informed design of site remedies and long-term stewardship of radionuclide-contaminated sites will require new cost-effective laboratory and field techniques to measure the parameters controlling mass transfer spatially and across a range of scales. In this project, we sought to capitalize on the geophysical signatures of mass transfer. Previous numerical modeling and pilot-scale field experiments suggested that mass transfer produces a geoelectrical signature—a hysteretic relation between sampled (mobile-domain) fluid conductivity and bulk (mobile + immobile) conductivity—over a range of scales relevant to aquifer remediation. In this work, we investigated the geoelectrical signature of mass transfer during tracer transport in a series of controlled experiments to determine the operation of controlling parameters, and also investigated the use of complex-resistivity (CR) as a means of quantifying mass transfer parameters in situ without tracer experiments. In an add-on component to our grant, we additionally considered nuclear magnetic resonance (NMR) to help parse mobile from immobile porosities. Including the NMR component, our revised study objectives were to: 1. Develop and demonstrate geophysical approaches to measure mass-transfer parameters spatially and over a range of scales, including the combination of electrical resistivity monitoring, tracer tests, complex resistivity, nuclear magnetic resonance, and materials characterization; and 2. Provide mass-transfer estimates for improved understanding of contaminant fate and transport at DOE sites, such as uranium transport at the Hanford 300 Area. To achieve our objectives, we implemented a 3

  13. Obtaining the Bunch Shape in a Linac from Beam Spectrum Measurements

    International Nuclear Information System (INIS)

    Bane, Karl LF

    1999-01-01

    In linacs with high single-bunch charge, and tight tolerances for energy spread and emittance growth, controlling the short-range wakefield effects becomes extremely important. The effects of the wakefields, in turn, depend on the bunch length and also on the bunch shape. It was shown in the linac of the Stanford Linear Collider (SLC), for example, that by shaping the bunch, the final rms energy spread could be greatly reduced, compared to for the standard Gaussian bunch shape[1]. Therefore, in machines with high single-bunch charge, a method of measuring bunch shape can be an important beam diagnostic. In a linac with low single-bunch charge, the longitudinal bunch shape can be obtained relatively easily from a single measurement of the beam's final energy spectrum, provided that the final to initial energy ratio is large. One merely shifts the average phase of the beam, so that it rides off-crest sufficiently to induce an energy variation that is monotonic with longitudinal position. Then, by knowing the initial and final energies, the rf wave number, and the average beam phase, one can directly map the spectrum into the bunch shape. In a linac with high single-bunch charge, however, due to the effect of the longitudinal wakefield, this method either does not work at all, or it requires such a large shift in beam phase as to become impractical. In earlier work[2],[3] it was shown that, even when wakefields are important, if one measures the final beam spectrum for two different (properly chosen) values of beam phase, then one can again obtain the bunch shape, and--as a by-product--also the form of the wakefield induced voltage; this method was then illustrated using data from the linac of the SLC. These SLC measurements, however, had been performed with the machine in a special configuration, where the current was low; in addition, the noise the data was low and the measured spectra were smooth distributions. Under normal SLC conditions, however, the currents

  14. The application of thermoluminescence dosimeter on the measurement of hard X-ray pulse energy spectrum

    International Nuclear Information System (INIS)

    Song Zhaohui; Wang Baohui; Wang Kuilu; Hei Dongwei; Sun Fengrong; Li Gang

    2001-01-01

    This paper introduce the application of thermoluminescence dosimeter (TLD) which composed by TLD-3500 Reader and TLD-100M chips on the measurement of hard X-ray pulse energy spectrum. The idea, using Filter Fluorescence Method (FFM) and TLD to measure hard X-ray pulse energy spectrum (from 10 keV to 100 keV), is discussed in details. Considering all the factors of the measuring surroundings, the measurement system of hard X-ray pulse has been devised. The calibration technique of absolute energy response of TLD is established. This method has been applied successfully on the radiation parameters measurement of the huge pulse radiation device -high-power pulser I. Hard X-ray pulse energy spectrum data of the pulser are acquired

  15. NEUTRON SPECTRUM MEASUREMENTS USING MULTIPLE THRESHOLD DETECTORS

    Energy Technology Data Exchange (ETDEWEB)

    Gerken, William W.; Duffey, Dick

    1963-11-15

    From American Nuclear Society Meeting, New York, Nov. 1963. The use of threshold detectors, which simultaneously undergo reactions with thermal neutrons and two or more fast neutron threshold reactions, was applied to measurements of the neutron spectrum in a reactor. A number of different materials were irradiated to determine the most practical ones for use as multiple threshold detectors. These results, as well as counting techniques and corrections, are presented. Some materials used include aluminum, alloys of Al -Ni, aluminum-- nickel oxides, and magesium orthophosphates. (auth)

  16. Procedure to measure the neutrons spectrum around a lineal accelerator for radiotherapy

    International Nuclear Information System (INIS)

    Vega C, H. R.; Hernandez D, V. M.; Letechipia de L, C.; Benites R, J. L.; Salas L, M. A.

    2013-10-01

    An experimental procedure was developed, by means of Bonner spheres, to measure the neutrons spectrum around Linacs of medical use that only requires of a single shot of the accelerator; to this procedure we denominate Planetary or Isocentric method. One of the problems associated to the neutrons spectrum measurement in a radiotherapy room with lineal accelerator is because inside the room a mixed, intense and pulsed radiation field takes place affecting the detection systems based on active detector; this situation is solved using a passive detector. In the case of the Bonner spheres spectrometer the active detector has been substituted by activation detectors, trace detectors or thermoluminescent dosimeters. This spectrometer uses several spheres that are situated one at a time in the measurement point, this way to have the complete measurements group the accelerator should be operated, under the same conditions, so many times like spheres have the spectrometer, this activity can consume a long time and in occasions due to the work load of Linac to complicate the measurement process too. The procedure developed in this work consisted on to situate all the spectrometer spheres at the same time and to make the reading by means of a single shot, to be able to apply this procedure, is necessary that before the measurements two characteristics are evaluated: the cross-talking of the spheres and the symmetry conditions of the neutron field. This method has been applied to determine the photo-neutrons spectrum produced by a lineal accelerator of medical use Varian ix of 15 MV to 100 cm of the isocenter located to 5 cm of depth of a solid water mannequin of 30 x 30 x 15 cm. The spectrum was used to determine the total flow and the environmental dose equivalent. (Author)

  17. High-SNR spectrum measurement based on Hadamard encoding and sparse reconstruction

    Science.gov (United States)

    Wang, Zhaoxin; Yue, Jiang; Han, Jing; Li, Long; Jin, Yong; Gao, Yuan; Li, Baoming

    2017-12-01

    The denoising capabilities of the H-matrix and cyclic S-matrix based on the sparse reconstruction, employed in the Pixel of Focal Plane Coded Visible Spectrometer for spectrum measurement are investigated, where the spectrum is sparse in a known basis. In the measurement process, the digital micromirror device plays an important role, which implements the Hadamard coding. In contrast with Hadamard transform spectrometry, based on the shift invariability, this spectrometer may have the advantage of a high efficiency. Simulations and experiments show that the nonlinear solution with a sparse reconstruction has a better signal-to-noise ratio than the linear solution and the H-matrix outperforms the cyclic S-matrix whether the reconstruction method is nonlinear or linear.

  18. Direct measurement of the partial decay energy of 7Be inner bremstrahlung spectrum

    International Nuclear Information System (INIS)

    Sanjeeviah, H.; Sanjeeviah, B.

    1978-01-01

    The inner bremsstrahlung spectrum accompanying orbital electron capture decay of 7 Be to the first excited state of 7 Li was measured in coincidence with 477 keV gamma rays. From the Jauch plot of the spectrum the partial decay energy was found to be 394 +- 16 keV. The shape factor of the inner bremsstrahlung spectrum close to the end point was accurately determined. It was found to be a constant X(1.001 +- 0.002) (author)

  19. The information spectrum as a measure of radiographic image quality and system performance

    International Nuclear Information System (INIS)

    Kanamori, H.; Matsumoto, M.

    1984-01-01

    The spectrum (spatial-frequency component) of the information capacity of a radiograph, here called the information spectrum, is offered as a measure of image quality and system performance. The information spectrum is a much more practical expression than information capacity by itself: it combines synthetically the contrast, the latitude, the sharpness and the granularity, and is expressed as a function of spatial frequency. The information spectrum can be readily calculated by using the dynamic density range and the MTF and noise Wiener spectrum at medium density range. A practical example is given. The appropriate system for each object can be selected by comparing the information spectral values of various imaging systems at the significant spatial frequency range predetermined for each object. (author)

  20. Measurement of fluorescence emission spectrum of few strongly driven atoms using an optical nanofiber.

    Science.gov (United States)

    Das, Manoj; Shirasaki, A; Nayak, K P; Morinaga, M; Le Kien, Fam; Hakuta, K

    2010-08-02

    We show that the fluorescence emission spectrum of few atoms can be measured by using an optical nanofiber combined with the optical heterodyne and photon correlation spectroscopy. The observed fluorescence spectrum of the atoms near the nanofiber shows negligible effects of the atom-surface interaction and agrees well with the Mollow triplet spectrum of free-space atoms at high excitation intensity.

  1. ATW neutron spectrum measurements at LAMPF

    Energy Technology Data Exchange (ETDEWEB)

    Butler, G.W.; Littleton, P.E.; Morgan, G.L. [Los Alamos National Laboratory, NM (United States)] [and others

    1995-10-01

    Accelerator transmutation of waste (ATW) is a proposal to use a high flux of accelerator-produced thermalized neutrons to transmute both fission product and higher actinide commercial nuclear waste into stable or short-lived radioactive species in order to avoid long-term storage of nuclear waste. At LAMPF the authors recently performed experiments that were designed to measure the spectrum of neutrons produced per incident proton for full-scale proposed ATW targets of lead and lithium. The neutrons produced in such targets have a spectrum of energies that extends up to the energy of the incident proton beam, but the distribution peaks between 1 and 5 MeV. Transmutation reactions and fission of actinides are most efficient when the neutron energy is below a few eV, so the target must be surrounded by a non-absorbing material (blanket) to produce additional neutrons and reduce the energy of high energy neutrons without loss. The experiments with the lead target, 25 cm diameter by 40 cm long, were conducted with 800 MeV protons, while those with the lithium target, 25 cm diameter by 175 cm long, were conducted with 400 MeV protons. The blanket in both sets of experiments was a 60 cm diameter by 200 cm long annulus of lead that surrounded the target. Surrounding the blanket was a steel water tank with dimensions of 250 cm diameter by 300 cm long that simulated the transmutation region. A small sample pipe penetrated the length of the lead blanket and other sample pipes penetrated the length of the water tank at different radii from the beam axis so that the neutron spectra at different locations could be measured by foil activation. After irradiation the activated foil sets were extracted and counted with calibrated high resolution germanium gamma ray detectors at the Los Alamos nuclear chemistry counting facility.

  2. Towards convective heat transfer enhancement: surface modification, characterization and measurement techniques

    NARCIS (Netherlands)

    Taha, T.J.; Thakur, D.B.; van der Meer, Theodorus H.

    2012-01-01

    In this work, heat transfer surface modification and heat transfer measurement technique is developed. Heat transfer investigation was aimed to study the effect of carbon nano fibers (extremely high thermal conductive material) on the enhancement level in heat transfer. Synthesis of these carbon

  3. Coherent radiation spectrum measurements at KEK LUCX facility

    Energy Technology Data Exchange (ETDEWEB)

    Shevelev, M., E-mail: mishe@post.kek.jp [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Aryshev, A., E-mail: alar@post.kek.jp [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Araki, S.; Fukuda, M. [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Karataev, P. [John Adams Institute at Royal Holloway, University of London, Egham, Surrey TW20 0EX (United Kingdom); Terunuma, N.; Urakawa, J. [KEK: High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2015-01-21

    This paper demonstrates the detailed design concept, alignment, and initial testing of a Michelson interferometer for the THz spectral range. We present the first results on the measurement of a coherent transition radiation spectrum and describe the performance of a pair of ultra-fast broadband room temperature Schottky barrier diode detectors. We discuss the main criteria of interferometer beam splitter optimization, the alignment technique, the high-precision calibration and linearity check of the motion system.

  4. Measurement of the ν{sub μ} energy spectrum with IceCube-79

    Energy Technology Data Exchange (ETDEWEB)

    Aartsen, M.G.; Hill, G.C.; Kyriacou, A.; Robertson, S.; Wallace, A.; Whelan, B.J. [University of Adelaide, Department of Physics, Adelaide (Australia); Ackermann, M.; Bernardini, E.; Blot, S.; Bradascio, F.; Bretz, H.P.; Franckowiak, A.; Jacobi, E.; Karg, T.; Kintscher, T.; Kunwar, S.; Nahnhauer, R.; Satalecka, K.; Spiering, C.; Stachurska, J.; Stasik, A.; Strotjohann, N.L.; Terliuk, A.; Usner, M.; Santen, J. van [DESY, Zeuthen (Germany); Adams, J.; Bagherpour, H. [University of Canterbury, Department of Physics and Astronomy, Christchurch (New Zealand); Aguilar, J.A.; Ansseau, I.; Heereman, D.; Meagher, K.; Meures, T.; O' Murchadha, A.; Pinat, E.; Raab, C. [Universite Libre de Bruxelles, Science Faculty CP230, Brussels (Belgium); Ahlers, M.; Braun, J.; Chirkin, D.; Day, M.; Desiati, P.; Diaz-Velez, J.C.; Fahey, S.; Feintzeig, J.; Ghorbani, K.; Gladstone, L.; Griffith, Z.; Halzen, F.; Hanson, K.; Hoshina, K.; Jero, K.; Karle, A.; Kauer, M.; Kelley, J.L.; Kheirandish, A.; Krueger, C.; Mancina, S.; McNally, F.; Merino, G.; Sabbatini, L.; Tobin, M.N.; Tosi, D.; Vandenbroucke, J.; Van Rossem, M.; Wandkowsky, N.; Wendt, C.; Westerhoff, S.; Wille, L.; Xu, D.L. [University of Wisconsin, Department of Physics and Wisconsin IceCube Particle Astrophysics Center, Madison, WI (United States); Ahrens, M.; Bohm, C.; Dumm, J.P.; Finley, C.; Flis, S.; Hultqvist, K.; Walck, C.; Wolf, M.; Zoll, M. [Stockholm University, Department of Physics, Oskar Klein Centre, Stockholm (Sweden); Al Samarai, I.; Bron, S.; Carver, T.; Christov, A.; Montaruli, T. [Universite de Geneve, Departement de physique nucleaire et corpusculaire, Geneva (Switzerland); Altmann, D.; Anton, G.; Gluesenkamp, T.; Katz, U.; Kittler, T.; Tselengidou, M. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Erlangen Centre for Astroparticle Physics, Erlangen (Germany); Andeen, K. [Marquette University, Department of Physics, Milwaukee, WI (United States); Anderson, T.; Dunkman, M.; Eller, P.; Huang, F.; Keivani, A.; Lanfranchi, J.L.; Pankova, D.V.; Quinnan, M.; Tesic, G.; Weiss, M.J. [Pennsylvania State University, Department of Physics, University Park, PA (United States); Archinger, M.; Baum, V.; Boeser, S.; Del Pino Rosendo, E.; Di Lorenzo, V.; Eberhardt, B.; Ehrhardt, T.; Foesig, C.C.; Koepke, L.; Krueckl, G.; Momente, G.; Peiffer, P.; Sandroos, J.; Steuer, A.; Wiebe, K. [University of Mainz, Institute of Physics, Mainz (Germany); Argueelles, C.; Axani, S.; Collin, G.H.; Conrad, J.M.; Jones, B.J.P.; Moulai, M. [Massachusetts Institute of Technology, Department of Physics, Cambridge, MA (United States); Auffenberg, J.; Glauch, T.; Haack, C.; Hansmann, T.; Konietz, R.; Leuermann, M.; Penek, Oe.; Raedel, L.; Reimann, R.; Rongen, M.; Schoenen, S.; Schumacher, L.; Stettner, J.; Vehring, M.; Vogel, E.; Wallraff, M.; Waza, A.; Wickmann, S.; Wiebusch, C.H. [RWTH Aachen University, III. Physikalisches Institut, Aachen (Germany); Bai, X. [South Dakota School of Mines and Technology, Physics Department, Rapid City, SD (United States); Barwick, S.W.; Yodh, G. [University of California, Department of Physics and Astronomy, Irvine, CA (United States); Bay, R.; Filimonov, K.; Price, P.B.; Woschnagg, K. [University of California, Department of Physics, Berkeley, CA (United States); Beatty, J.J. [Ohio State University, Department of Physics and Center for Cosmology and Astro-Particle Physics, Columbus, OH (United States); Ohio State University, Department of Astronomy, Columbus, OH (United States); Becker Tjus, J.; Bos, F.; Eichmann, B.; Kroll, M.; Schoeneberg, S.; Tenholt, F. [Ruhr-Universitaet Bochum, Fakultaet fuer Physik and Astronomie, Bochum (Germany); Becker, K.H.; Bindig, D.; Helbing, K.; Hickford, S.; Hoffmann, R.; Kopper, S.; Lauber, F.; Naumann, U.; Obertacke Pollmann, A.; Soldin, D. [University of Wuppertal, Department of Physics, Wuppertal (Germany); BenZvi, S.; Cross, R. [University of Rochester, Department of Physics and Astronomy, Rochester, NY (United States); Berley, D.; Blaufuss, E.; Cheung, E.; Felde, J.; Friedman, E.; Hellauer, R.; Hoffman, K.D.; Maunu, R.; Olivas, A.; Schmidt, T.; Song, M.; Sullivan, G.W. [University of Maryland, Department of Physics, College Park, MD (United States); Besson, D.Z. [University of Kansas, Department of Physics and Astronomy, Lawrence, KS (United States); Binder, G.; Gerhardt, L.; Klein, S.R.; Miarecki, S.; Palczewski, T.; Tatar, J. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Boerner, M.; Fuchs, T.; Meier, M.; Menne, T.; Pieloth, D.; Rhode, W.; Ruhe, T.; Sandrock, A.; Schlunder, P. [TU Dortmund University, Department of Physics, Dortmund (Germany); Collaboration: IceCube Collaboration; and others

    2017-10-15

    IceCube is a neutrino observatory deployed in the glacial ice at the geographic South Pole. The ν{sub μ} energy unfolding described in this paper is based on data taken with IceCube in its 79-string configuration. A sample of muon neutrino charged-current interactions with a purity of 99.5% was selected by means of a multivariate classification process based on machine learning. The subsequent unfolding was performed using the software Truee. The resulting spectrum covers an E{sub ν}-range of more than four orders of magnitude from 125 GeV to 3.2 PeV. Compared to the Honda atmospheric neutrino flux model, the energy spectrum shows an excess of more than 1.9σ in four adjacent bins for neutrino energies E{sub ν} ≥ 177.8 TeV. The obtained spectrum is fully compatible with previous measurements of the atmospheric neutrino flux and recent IceCube measurements of a flux of high-energy astrophysical neutrinos. (orig.)

  5. Measurement of the dipion mass spectrum in decays.

    Science.gov (United States)

    Abulencia, A; Acosta, D; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arguin, J-F; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Bachacou, H; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Belloni, A; Ben Haim, E; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Bishai, M; Blair, R E; Blocker, C; Bloom, K; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Bourov, S; Boveia, A; Brau, B; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carlsmith, D; Carosi, R; Carron, S; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chapman, J; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Chu, P H; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciljak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Connolly, A; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Cruz, A; Cuevas, J; Culbertson, R; Cyr, D; Daronco, S; D'Auria, S; D'onofrio, M; Dagenhart, D; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; Dell'orso, M; Demers, S; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Dionisi, C; Dittmann, J R; DiTuro, P; Dörr, C; Dominguez, A; Donati, S; Donega, M; Dong, P; Donini, J; Dorigo, T; Dube, S; Ebina, K; Efron, J; Ehlers, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Flores-Castillo, L R; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J C; Fujii, Y; Furic, I; Gajjar, A; Gallinaro, M; Galyardt, J; Garcia, J E; Garcia Sciveres, M; Garfinkel, A F; Gay, C; Gerberich, H; Gerchtein, E; Gerdes, D; Giagu, S; di Giovanni, G P; Giannetti, P; Gibson, A; Gibson, K; Ginsburg, C; Giokaris, N; Giolo, K; Giordani, M; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Gotra, Y; Goulianos, K; Gresele, A; Griffiths, M; Grinstein, S; Grosso-Pilcher, C; Grundler, U; Guimaraes da Costa, J; Haber, C; Hahn, S R; Hahn, K; Halkiadakis, E; Hamilton, A; Han, B-Y; Handler, R; Happacher, F; Hara, K; Hare, M; Harper, S; Harr, R F; Harris, R M; Hatakeyama, K; Hauser, J; Hays, C; Hayward, H; Heijboer, A; Heinemann, B; Heinrich, J; Hennecke, M; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Huston, J; Ikado, K; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jensen, H; Jeon, E J; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Kang, J; Karagoz-Unel, M; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, M S; Kim, S B; Kim, S H; Kim, Y K; Kirby, M; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kobayashi, H; Kondo, K; Kong, D J; Konigsberg, J; Kordas, K; Korytov, A; Kotwal, A V; Kovalev, A; Kraus, J; Kravchenko, I; Kreps, M; Kreymer, A; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kuhlmann, S E; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecci, C; Lecompte, T; Lee, J; Lee, J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Li, K; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Liss, T M; Lister, A; Litvintsev, D O; Liu, T; Liu, Y; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; MacQueen, D; Madrak, R; Maeshima, K; Maksimovic, P; Manca, G; Margaroli, F; Marginean, R; Marino, C; Martin, A; Martin, M; Martin, V; Martínez, M; Maruyama, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McGivern, D; McIntyre, P; McNamara, P; McNulty, R; Mehta, A; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; von der Mey, M; Miao, T; Miladinovic, N; Miles, J; Miller, R; Miller, J S; Mills, C; Milnik, M; Miquel, R; Miscetti, S; Mitselmakher, G; Miyamoto, A; Moggi, N; Mohr, B; Moore, R; Morello, M; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Mulhearn, M; Muller, Th; Mumford, R; Murat, P; Nachtman, J; Nahn, S; Nakano, I; Napier, A; Naumov, D; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nigmanov, T; Nodulman, L; Norniella, O; Ogawa, T; Oh, S H; Oh, Y D; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Paoletti, R; Papadimitriou, V; Papikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pitts, K; Plager, C; Pondrom, L; Pope, G; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Rakitin, A; Rappoccio, S; Ratnikov, F; Reisert, B; Rekovic, V; van Remortel, N; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Rinnert, K; Ristori, L; Robertson, W J; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Rott, C; Ruiz, A; Russ, J; Rusu, V; Ryan, D; Saarikko, H; Sabik, S; Safonov, A; Sakumoto, W K; Salamanna, G; Salto, O; Saltzberg, D; Sanchez, C; Santi, L; Sarkar, S; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Semeria, F; Sexton-Kennedy, L; Sfiligoi, I; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sill, A; Sinervo, P; Sisakyan, A; Sjolin, J; Skiba, A; Slaughter, A J; Sliwa, K; Smirnov, D; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sumorok, K; Sun, H; Suzuki, T; Taffard, A; Tafirout, R; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Tether, S; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Tönnesmann, M; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuchiya, R; Tsuno, S; Turini, N; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vacavant, L; Vaiciulis, A; Vallecorsa, S; Varganov, A; Vataga, E; Velev, G; Veramendi, G; Veszpremi, V; Vickey, T; Vidal, R; Vila, I; Vilar, R; Vollrath, I; Volobouev, I; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wallny, R; Walter, T; Wan, Z; Wang, M J; Wang, S M; Warburton, A; Ward, B; Waschke, S; Waters, D; Watts, T; Weber, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Worm, S; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zetti, F; Zhang, X; Zhou, J; Zucchelli, S

    2006-03-17

    We measure the dipion mass spectrum in X(3872)--> J/psipi(+) pi(-) decays using 360 pb(-1) of pp collisions at square root s= 1.96 TeV collected with the CDF II detector. The spectrum is fit with predictions for odd C-parity ((3)S(1), (1)P(1), and (3)D(J)) charmonia decaying to J/psipi(+) pi(-), as well as even C-parity states in which the pions are from rho(0) decay. The latter case also encompasses exotic interpretations, such as a D(0)D(*0) molecule. Only the (3)S(1) and J/psirho hypotheses are compatible with our data. Since (3)S(1) is untenable on other grounds, decay via J/psirho is favored, which implies C= +1 for the X(3872). Models for J/psi - rho different angular momenta L are considered. Flexibility in the models, especially the introduction of rho - omega interference, enables good descriptions of our data for both L = 0 and 1.

  6. Measurement and model of the infrared two-photon emission spectrum of GaAs.

    Science.gov (United States)

    Hayat, Alex; Ginzburg, Pavel; Orenstein, Meir

    2009-07-10

    Two-photon emission from semiconductors was recently observed, but not fully interpreted. We develop a dressed-state model incorporating intraband scattering-related level broadening, yielding nondivergent emission rates. The spectrum calculations for high carrier concentrations including the time dependence of the screening buildup correspond well to our measured two-photon emission spectrum from GaAs.

  7. Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Huang, J., E-mail: juan.huang@ipp.ac.cn; Wu, C. R.; Hou, Y. M.; Chang, J. F.; Ding, S. Y.; Chen, Y. J.; Jin, Z.; Xu, Z.; Gao, W.; Wang, J. F.; Lyu, B.; Zang, Q.; Zhong, G. Q.; Hu, L.; Wan, B. [Institute of Plasma Physics, Chinese Academy of Sciences, P.O. Box 1126, 230031 Hefei, Anhui (China); Heidbrink, W. W.; Stagner, L.; Zhu, Y. B. [University of California, Irvine, California 92697 (United States); Hellermann, M. G. von [Diagnostic Team, ITER Organization, Route de Vinon-sur-Verdon 13067 St. Paul Lez Durance (France)

    2016-11-15

    To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been installed on EAST. Fast ion features can be inferred from the Doppler shifted spectrum of Balmer-alpha light from energetic hydrogenic atoms. This paper will focus on the validation of FIDA measurements performed using MHD-quiescent discharges in 2015 campaign. Two codes have been applied to calculate the D{sub α} spectrum: one is a Monte Carlo code, Fortran 90 version FIDASIM, and the other is an analytical code, Simulation of Spectra (SOS). The predicted SOS fast-ion spectrum agrees well with the measurement; however, the level of fast-ion part from FIDASIM is lower. The discrepancy is possibly due to the difference between FIDASIM and SOS velocity distribution function. The details will be presented in the paper to primarily address comparisons of predicted and observed spectrum shapes/amplitudes.

  8. First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of $^{163}$Ho

    CERN Document Server

    Ranitzsch, P. C. -O.; Wegner, M.; Kempf, S.; Fleischmann, A.; Enss, C.; Gastaldo, L.; Herlert, A.; Johnston, K.

    2014-01-01

    The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on the analysis of the calorimetrically measured spectrum. We present for the first time the calorimetric measurement of the atomic de-excitation of the $^{163}$Dy daughter atom upon the capture of an electron from the 5s shell in $^{163}$Ho, OI-line. The measured peak energy is 48 eV. This measurement was performed using low temperature metallic magnetic calorimeters with the $^{163}$Ho ion implanted in the absorber. We demonstrate that the calorimetric spectrum of $^{163}$Ho can be measured with high precision and that the parameters describing the spectrum can be learned from the analysis of the data. Finally, we dis...

  9. Using activation method to measure neutron spectrum in an irradiation chamber of a research reactor

    International Nuclear Information System (INIS)

    Zhou Xuemei; Liu Guimin; Wang Xiaohe; Li Da; Meng Lingjie

    2014-01-01

    Neutron spectrum should be measured before test samples are irradiated. Neutron spectrum in an irradiation chamber of a research reactor was measured by using activation method when the reactor is in normal operation under 2 MW. Sixteen kinds of non-fission foils (19 reaction channels) were selected, of which 10 were sensitive to thermal and intermediate energy regions, while the others were of different threshold energy and sensitive to fast energy regions. By measuring the foil radioactivity, the neutron spectrum was unfolded with the iterative methods SAND-II and MSIT. Finally, shielding corrections of group cross-section and main factors affecting the calculation accuracy were studied and the uncertainty of solution was analyzed using the Monte Carlo method in the process of SAND-II. (authors)

  10. Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Day-Lewis, Frederick David [US Geological Survey, Storrs, CT (United States); Singha, Kamini [Colorado School of Mines, Golden, CO (United States); Johnson, Timothy C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Haggerty, Roy [Oregon State Univ., Corvallis, OR (United States); Binley, Andrew [Lancaster Univ. (United Kingdom); Lane, John W. [US Geological Survey, Storrs, CT (United States)

    2014-11-25

    Mass transfer affects contaminant transport and is thought to control the efficiency of aquifer remediation at a number of sites within the Department of Energy (DOE) complex. An improved understanding of mass transfer is critical to meeting the enormous scientific and engineering challenges currently facing DOE. Informed design of site remedies and long-term stewardship of radionuclide-contaminated sites will require new cost-effective laboratory and field techniques to measure the parameters controlling mass transfer spatially and across a range of scales. In this project, we sought to capitalize on the geophysical signatures of mass transfer. Previous numerical modeling and pilot-scale field experiments suggested that mass transfer produces a geoelectrical signature—a hysteretic relation between sampled (mobile-domain) fluid conductivity and bulk (mobile + immobile) conductivity—over a range of scales relevant to aquifer remediation. In this work, we investigated the geoelectrical signature of mass transfer during tracer transport in a series of controlled experiments to determine the operation of controlling parameters, and also investigated the use of complex-resistivity (CR) as a means of quantifying mass transfer parameters in situ without tracer experiments. In an add-on component to our grant, we additionally considered nuclear magnetic resonance (NMR) to help parse mobile from immobile porosities. Including the NMR component, our revised study objectives were to: 1. Develop and demonstrate geophysical approaches to measure mass-transfer parameters spatially and over a range of scales, including the combination of electrical resistivity monitoring, tracer tests, complex resistivity, nuclear magnetic resonance, and materials characterization; and 2. Provide mass-transfer estimates for improved understanding of contaminant fate and transport at DOE sites, such as uranium transport at the Hanford 300 Area. To achieve our objectives, we implemented a 3

  11. Quadrupole Transfer Function for Emittance Measurement

    CERN Document Server

    Cameron, Peter; Jansson, Andreas; Tan, Cheng-Yang

    2008-01-01

    Historically the use of the quadrupole moment measurement has been impeded by the requirement for large dynamic range, as well as measurement sensitivity to beam position. We investigate the use of the transfer function technique [1-3] in combination with the sensitivity and 160dB revolution line rejection of the direct diode detection analog front end [4] to open the possibility of an emittance diagnostic that may be implemented without operational complication, quasi- parasitic to the operation of existing tune measurement systems. Such a diagnostic would be particularly useful as an emittance monitor during acceleration ramp development in machines like RHIC and the LHC.

  12. New measurements of the spectrum of the cosmic microwave background

    International Nuclear Information System (INIS)

    Peterson, J.B.; Richards, P.L.; Bonomo, J.L.; Timusk, T.

    1986-01-01

    Accurate measurements of the spectrum of the cosmic microwave background (CMB) can provide useful tests of cosmological theories. The data set existing in 1982 has been summarized on a number of occasions. To first approximation the CMB is characterized by a single temperature and thus has a blackbody spectrum over the frequency range from 0.02 to 24 cm/sup -1/. The error limits given for these experiments are dominated by systematic errors and are often very subjective. Consequently, it is not clear how to analyze the data set in a valid way. The general impression, however, is of a scatter in the high frequency data that is somewhat larger than would be expected from the given error limits

  13. Outdoor measurements of a photovoltaic system using diffractive spectrum-splitting and concentration

    Directory of Open Access Journals (Sweden)

    N. Mohammad

    2016-09-01

    Full Text Available In a single-bandgap absorber, photons having energy less than the bandgap are not absorbed, while those having energy larger than the bandgap lose the excess energy via thermalization. We present outdoor measurements of a photovoltaic system that overcomes these losses via spectrum splitting and concentration using a planar diffractive optic. The system was comprised of the diffractive optic coupled with GaInP and CIGS solar cells. The optic provides a geometric concentration of 3X for each solar cell. It is easily fabricated by single-step grayscale lithography and it is ultra-thin with a maximum thickness of only 2.5μm. Electrical measurements under direct sunlight demonstrated an increase of ∼25% in total output power compared to the reference case without spectrum splitting and concentration. Since different bandgaps are in the same plane, the proposed photovoltaic system successfully circumvents the lattice-matching and current-matching issues in conventional tandem multi-junction solar cells. This system is also tolerant to solar spectrum variation and fill-factor degradation of constitutive solar cells.

  14. Use of Advanced Magnetic Resonance Imaging Techniques in Neuromyelitis Optica Spectrum Disorder

    DEFF Research Database (Denmark)

    Kremer, S.; Renard, F.; Achard, S.

    2015-01-01

    Brain parenchymal lesions are frequently observed on conventional magnetic resonance imaging (MRI) scans of patients with neuromyelitis optica (NMO) spectrum disorder but the specific morphological and temporal patterns distinguishing them uneqtaivcally from lesions caused by other disorders have...... not been identified. This literature review summarizes the literature on advanced quantitative imaging measures reported for patients with NMO spectrum disorder, including proton MR spectroscopy, diffusion tensor imaging, magnetization transfer imaging, quantitative MR voltametry, and ultrahigh...... diffusion-weighted imaging and brain tissue volumetry indicate greater white matter than gray matter degradation. These findings could be confirmed by ultrahigh-field MRI. The use of nonconventional MR I techniques may further our understanding of the pathogenic processes hi NMO spectrum disorders and may...

  15. Measuring Social Communication Behaviors as a Treatment Endpoint in Individuals with Autism Spectrum Disorder

    Science.gov (United States)

    Anagnostou, Evdokia; Jones, Nancy; Huerta, Marisela; Halladay, Alycia K.; Wang, Paul; Scahill, Lawrence; Horrigan, Joseph P.; Kasari, Connie; Lord, Cathy; Choi, Dennis; Sullivan, Katherine; Dawson, Geraldine

    2015-01-01

    Social communication impairments are a core deficit in autism spectrum disorder. Social communication deficit is also an early indicator of autism spectrum disorder and a factor in long-term outcomes. Thus, this symptom domain represents a critical treatment target. Identifying reliable and valid outcome measures for social communication across a…

  16. Measured and Predicted Variations in Fast Neutron Spectrum when Penetrating Laminated Fe-D2O

    International Nuclear Information System (INIS)

    Aalto, E.; Sandlin, R.; Fraeki, R.

    1965-09-01

    Variations of the fast neutron spectrum in thin regions of alternating Fe and D O have been studied using threshold detectors (ln(n, n' ), S(n, p), Al(n, α)). The results have been compared to those calculated by two shielding codes (NRN and RASH D) of multigroup removal-diffusion type. The absolute fast spectrum calculated in our rather complicated configurations was found to agree with measurements within the same accuracy (a factor of two) as did the thermal flux. The calculated spectrum is slightly harder than the measured one, but the detailed variations (covering the range 1:5) in the form of the spectrum when penetrating Fe agree with observations to within 15-20 %. In and Al activities were found to be proportional to the integrated flux over 1 MeV throughout the whole configuration, while S showed the least proportionality

  17. Measurement and analysis of reaction rate distributions of cores with spectrum shifter region

    International Nuclear Information System (INIS)

    Matsuura, Shigekazu; Shiroya, Seiji; Unesaki, Hironobu; Takeda, Toshikazu; Aizawa, Otohiko; Kanda, Keiji.

    1995-01-01

    A study for the neutronic characteristics of the spectrum-controlled neutron irradiation fields using various reflector materials was performed. Spectrum shifter regions were constructed in the upper reflector region of the solid moderated core (B-Core) of the Kyoto University Critical Assembly (KUCA). Beryllium, graphite and aluminum were selected as the loading materials for the spectrum shifter. Two tight-pitch lattice cores with different moderator-to-fuel volume ratio (V m /V f ) of 0.97 and 0.65 have been used. Axial reaction rate distributions of gold, nickel and indium wires were measured, and the spectrum index was defined as the Cd ratio of the gold wire and the ratio of gold reaction rate to nickel reaction rate. Using the conventional design calculation procedure, the experimental and calculated reaction rate and spectrum index show several disagreements. Detailed treatment of the neutron streaming effect, heterogeneous cell structure and depression factor are shown to be necessary for improving the agreement between experimental and calculated values. (author)

  18. Neutron spectrum measurement in D + Be reaction

    CERN Document Server

    Abbasi-Davani, F; Aslani, G R; Etaati, G R; Koohi-Fayegh, R

    2002-01-01

    In this project the neutron spectra from the reaction of deuteron on beryllium nuclei is measured. The energies of deuterons were 7, 10, 13 and 15 MeV, and these measurements are performed at 10,30 and 50 degrees relative to the beam of deuterons. The detector used is 76 by 76 mm right circular cylinder of N E-213 liquid scintillator. The zero crossing technique is used for gamma discrimination. For the elimination of the background radiation, a Polyethylene block, 40 cm in thickness, with inserted cadmium sheets, and a lead block, 5 cm in thickness, were used. In order to obtain the background radiation spectrum, the latter blocks were placed between the target and the detector to eliminate neutron and gamma radiations reaching the detector directly. sup F ORIST sup c ode is used to unfold the neutron spectra from the measured pulse high t spectra and sup O 5S sup a nd sup R ESPMG sup c odes are used to obtain the detector response matrix.

  19. Evaluating parameterizations of aerodynamic resistance to heat transfer using field measurements

    Directory of Open Access Journals (Sweden)

    Shaomin Liu

    2007-01-01

    Full Text Available Parameterizations of aerodynamic resistance to heat and water transfer have a significant impact on the accuracy of models of land – atmosphere interactions and of estimated surface fluxes using spectro-radiometric data collected from aircrafts and satellites. We have used measurements from an eddy correlation system to derive the aerodynamic resistance to heat transfer over a bare soil surface as well as over a maize canopy. Diurnal variations of aerodynamic resistance have been analyzed. The results showed that the diurnal variation of aerodynamic resistance during daytime (07:00 h–18:00 h was significant for both the bare soil surface and the maize canopy although the range of variation was limited. Based on the measurements made by the eddy correlation system, a comprehensive evaluation of eight popularly used parameterization schemes of aerodynamic resistance was carried out. The roughness length for heat transfer is a crucial parameter in the estimation of aerodynamic resistance to heat transfer and can neither be taken as a constant nor be neglected. Comparing with the measurements, the parameterizations by Choudhury et al. (1986, Viney (1991, Yang et al. (2001 and the modified forms of Verma et al. (1976 and Mahrt and Ek (1984 by inclusion of roughness length for heat transfer gave good agreements with the measurements, while the parameterizations by Hatfield et al. (1983 and Xie (1988 showed larger errors even though the roughness length for heat transfer has been taken into account.

  20. Chromaticity measurement via the fourier spectrum of transverse oscillations

    International Nuclear Information System (INIS)

    Xi Yang

    2004-01-01

    Turn-by-turn data from a single BPM includes information on the chromaticity in sidebands displaced above and below the betatron frequency by an amount of the synchrotron frequency. It may be necessary to induce small amplitude synchrotron oscillation by giving the beam a small kick. Power spectrum of the BPM data gives clear chromatic sidebands, and they can be applied to the chromaticity measurement in the Fermilab Booster

  1. Measurements of actinide transmutation in the hard spectrum of a fast reactor

    International Nuclear Information System (INIS)

    Trybus, C.L.; Collins, P.J.; Maddison, D.W.; Bunde, K.A.; Pallmtag, S.; Palmiotti, G.

    1994-01-01

    Measurements of fission and capture in 235 U, 238 U, 239 Pu and 237 Np and in their product actinides have been made following irradiation in the metal-fuel core of EBR-II. The reactor has a peak flux around 500keV and the data complement measurements in the softer spectrum of an LMFBR. Irradiations were made at the same time for a set of standard dosimeter samples. These provide a test of calculated spectra and are also used for validation of steel activations and calculated atomic displacement rates. Calculation were made with modem transport codes using ENDF/B-5.2 data. Comparisons are made, using a simple homogeneous model, producing a similar spectrum, using ENDF/B-6.2 and JEFF-2 data

  2. Development of ultrasonic heat transfer tube thickness measurement apparatus. Contract research

    Energy Technology Data Exchange (ETDEWEB)

    Ohba, Toshihiro; Katoh, Chiaki; Yanagihara, Takao [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Suetugu, Hidehiko; Yano, Masaya [Sumitomo Chemical Co., Ltd., Tokyo (Japan)

    2003-01-01

    The demonstration test for evaluating reliability of the acid recovery evaporator at Rokkasho Reprocessing Plant has been carried out at JAERI. For the nondestructive measurement of the thickness of heat transfer tubes of the acid recovery evaporator in corrosion test, we have developed thickness measurement apparatus for heat transfer tubes by ultrasonic immersion method with high resolution. The ultrasonic prove in a heat transfer tube can be moved vertically and radially. The results obtained by this apparatus coincident well with those obtained by a destructive method using an optical microscope. (author)

  3. Technology transfer from biomedical research to clinical practice: measuring innovation performance.

    Science.gov (United States)

    Balas, E Andrew; Elkin, Peter L

    2013-12-01

    Studies documented 17 years of transfer time from clinical trials to practice of care. Launched in 2002, the National Institutes of Health (NIH) translational research initiative needs to develop metrics for impact assessment. A recent White House report highlighted that research and development productivity is declining as a result of increased research spending while the new drugs output is flat. The goal of this study was to develop an expanded model of research-based innovation and performance thresholds of transfer from research to practice. Models for transfer of research to practice have been collected and reviewed. Subsequently, innovation pathways have been specified based on common characteristics. An integrated, intellectual property transfer model is described. The central but often disregarded role of research innovation disclosure is highlighted. Measures of research transfer and milestones of progress have been identified based on the Association of University Technology Managers 2012 performance reports. Numeric milestones of technology transfer are recommended at threshold (top 50%), target (top 25%), and stretch goal (top 10%) performance levels. Transfer measures and corresponding target levels include research spending to disclosure (0.81), patents to start-up (>0.1), patents to licenses (>2.25), and average per license income (>$48,000). Several limitations of measurement are described. Academic institutions should take strategic steps to bring innovation to the center of scholarly discussions. Research on research, particularly on pathways to disclosures, is needed to improve R&D productivity. Researchers should be informed about the technology transfer performance of their institution and regulations should better support innovators.

  4. Measuring and teaching light spectrum using Tracker as a spectrometer

    Science.gov (United States)

    Rodrigues, M.; Marques, M. B.; Simeão Carvalho, P.

    2015-10-01

    In this work we present a simple and low cost setup that allows obtaining the light spectra and measuring the wavelength of its features. It is based on a cheap transmission diffraction grating, an ordinary digital camera and using Tracker software to increase measuring accuracy. This equipment can easily be found in most schools. The experimental setup is easy to implement (the typical setup for a pocket spectroscope) replacing the eye with the camera. The calibration is done using a light source with a well-known spectrum. The acquired images are analyzed with Tracker (freeware software frequently used for motion studies). With this system, we have analyzed several light sources. As an example, the analysis of the spectra obtained with compact fluorescent lamp allowed to recognize the spectrum of mercury in the lamp, as expected. This spectral analysis is therefore useful in schools, among other topics, to enable the recognition of chemical elements through spectroscopy, and to alert students to the different spectra of illuminating light sources used in houses and public places.

  5. Measurement of the beta spectrum of the 0/sup -/ (120 keV) state of /sup 16/N

    Energy Technology Data Exchange (ETDEWEB)

    Champagne, A; Beaudoin, G; Hamel, L A; Jeremie, H; Lessard, L

    1988-08-01

    We have measured the beta spectrum of the 0/sup -/ (120 keV, t/sub 1/2/ = 5.25 ..mu..s) state of /sup 16/N. The response function of our detector has been measured, parameterized and then fitted to known spectral shapes taken under conditions close to those in the actual experiment. Using this response function and subtracting a 56 ..mu..s half-life background due to neutron capture in the detector, the measured 0/sup -/ spectrum compares well with the allowed shape for the 0/sup -/ -> 0/sup +/ spectrum plus a small contribution from the allowed 0/sup -/ -> 1/sup -/ transition.

  6. Measuring Theory of Mind in Adults with Autism Spectrum Disorder

    Science.gov (United States)

    Brewer, Neil; Young, Robyn L.; Barnett, Emily

    2017-01-01

    Deficits in Theory of Mind (ToM)--the ability to interpret others' beliefs, intentions and emotions--undermine the ability of individuals with Autism Spectrum Disorder (ASD) to interact in socially normative ways. This study provides psychometric data for the Adult-Theory of Mind (A-ToM) measure using video-scenarios based in part on Happé's…

  7. Measuring Anxiety as a Treatment Endpoint in Youth with Autism Spectrum Disorder

    Science.gov (United States)

    Lecavalier, Luc; Wood, Jeffrey J.; Halladay, Alycia K.; Jones, Nancy E.; Aman, Michael G.; Cook, Edwin H.; Handen, Benjamin L.; King, Bryan H.; Pearson, Deborah A.; Hallett, Victoria; Sullivan, Katherine Anne; Grondhuis, Sabrina; Bishop, Somer L.; Horrigan, Joseph P.; Dawson, Geraldine; Scahill, Lawrence

    2014-01-01

    Despite the high rate of anxiety in individuals with autism spectrum disorder (ASD), measuring anxiety in ASD is fraught with uncertainty. This is due, in part, to incomplete consensus on the manifestations of anxiety in this population. Autism Speaks assembled a panel of experts to conduct a systematic review of available measures for anxiety in…

  8. Measurement of Gamma Spectrum at domestic Nuclear Power Plant with CZT Semiconductor Detector

    Energy Technology Data Exchange (ETDEWEB)

    Kon, Kang Seo; Yoon, Kang Hwa; Lee, Byoung Il; Kim, Jeong In [KHNP, Radiation Health Research Institute, Seoul (Korea, Republic of)

    2013-10-15

    In this study we monitored gamma spectrum for young S/G to see difference of the detected nuclides between old and young S/G. The detected source terms were the same for all measurement points. There is not comparison of quantity among the nuclides. The program which analyzes gamma spectrum to calculate activity and dose rate is under developing. We expect it will be done by end of this year. In this study we could see the difference of detected nuclides between old and new S/G for the first time whereas last measurement has significant meaning in that the measurement was taken for the first time all over country. Monitoring sources terms at Nuclear Power Plant(NPP) is important to aggressive ALARA activities and evaluation of exposure of workers. EDF (Electricite de France) and AEP (American Electric Power) conduct monitoring source terms using by CZT semiconductor detector. CZT is different from HPGe in that it does not need any cooling system at room temperature, it has good energy resolution and it can be made portable type easily. For these reason CZT is used in various fields commercially to measure gamma ray and therefore KHNP(Korea Hydro and Nuclear Power Co., LTD) RHRI(Radiation Health Research Institute) has been measuring gamma spectrum at domestic NPP last spring. We had have presented the first result through the last Transactions of the Korean Nuclear Society Spring Meeting for old S/G(Steam Generator)

  9. Cortisol Measures Across the Weight Spectrum.

    Science.gov (United States)

    Schorr, Melanie; Lawson, Elizabeth A; Dichtel, Laura E; Klibanski, Anne; Miller, Karen K

    2015-09-01

    There are conflicting reports of increased vs decreased hypothalamic-pituitary-adrenal (HPA) activation in obesity; the most consistent finding is an inverse relationship between body mass index (BMI) and morning cortisol. In anorexia nervosa (AN), a low-BMI state, cortisol measures are elevated. This study aimed to investigate cortisol measures across the weight spectrum. This was a cross-sectional study at a clinical research center. This study included 60 women, 18-45 years of age: overweight/obese (OB; N = 21); AN (N = 18); and normal-weight controls (HC; N = 21). HPA dynamics were assessed by urinary free cortisol, mean overnight serum cortisol obtained by pooled frequent sampling every 20 minutes from 2000-0800 h, 0800 h serum cortisol and cortisol-binding globulin, morning and late-night salivary cortisol, and dexamethasone-CRH testing. Body composition and bone mineral density (BMD) were assessed by dual-energy x-ray absorptiometry. Cortisol measures demonstrated a U-shaped relationship with BMI, nadiring in the overweight-class I obese range, and were similarly associated with visceral adipose tissue and total fat mass. Mean cortisol levels were higher in AN than OB. There were weak negative linear relationships between lean mass and some cortisol measures. Most cortisol measures were negatively associated with postero-anterior spine and total hip BMD. Cortisol measures are lowest in overweight-class I obese women-lower than in lean women. With more significant obesity, cortisol levels increase, although not to as high as in AN. Therefore, extreme underweight and overweight states may activate the HPA axis, and hypercortisolemia may contribute to increased adiposity in the setting of caloric excess. Hypercortisolemia may also contribute to decreased BMD and muscle wasting in the setting of both caloric restriction and excess.

  10. Measurement of spectrum at the experimental 6.5 MW reactor in Vinca; Merenje spektra na eksperimentalnom 6,5 MW reaktoru u Vinci

    Energy Technology Data Exchange (ETDEWEB)

    Berovic, N; Boreli, F; Aleksic, N; Dragin, R [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)

    1961-07-01

    Since RA reactor is supplied with horizontal experimental channels which lead directly to the core fast neutron spectrum in the channel does not differ much from the neutron spectrum in the core. Spectrum was measured by 'telescope' for detecting scattered protons. Measuring procedure together with the measured spectrum are presented in this paper.

  11. An angle-dependent estimation of CT x-ray spectrum from rotational transmission measurements

    International Nuclear Information System (INIS)

    Lin, Yuan; Samei, Ehsan; Ramirez-Giraldo, Juan Carlos; Gauthier, Daniel J.; Stierstorfer, Karl

    2014-01-01

    Purpose: Computed tomography (CT) performance as well as dose and image quality is directly affected by the x-ray spectrum. However, the current assessment approaches of the CT x-ray spectrum require costly measurement equipment and complicated operational procedures, and are often limited to the spectrum corresponding to the center of rotation. In order to address these limitations, the authors propose an angle-dependent estimation technique, where the incident spectra across a wide range of angular trajectories can be estimated accurately with only a single phantom and a single axial scan in the absence of the knowledge of the bowtie filter. Methods: The proposed technique uses a uniform cylindrical phantom, made of ultra-high-molecular-weight polyethylene and positioned in an off-centered geometry. The projection data acquired with an axial scan have a twofold purpose. First, they serve as a reflection of the transmission measurements across different angular trajectories. Second, they are used to reconstruct the cross sectional image of the phantom, which is then utilized to compute the intersection length of each transmission measurement. With each CT detector element recording a range of transmission measurements for a single angular trajectory, the spectrum is estimated for that trajectory. A data conditioning procedure is used to combine information from hundreds of collected transmission measurements to accelerate the estimation speed, to reduce noise, and to improve estimation stability. The proposed spectral estimation technique was validated experimentally using a clinical scanner (Somatom Definition Flash, Siemens Healthcare, Germany) with spectra provided by the manufacturer serving as the comparison standard. Results obtained with the proposed technique were compared against those obtained from a second conventional transmission measurement technique with two materials (i.e., Cu and Al). After validation, the proposed technique was applied to measure

  12. Modeling the bacterial photosynthetic reaction center. VII. Full simulation of the intervalence hole-transfer absorption spectrum of the special-pair radical cation

    International Nuclear Information System (INIS)

    Reimers, Jeffrey R.; Hush, Noel S.

    2003-01-01

    ENDOR data suggests that the special-pair radical cation P + from Rhodobacter sphaeroides is 68% localized on P L while simple interpretations of FTIR difference spectra based primarily on intensity information, but to some extent also bandwidths, suggest near-complete charge localization. We provide a complete a priori spectral simulation of the spectrum of P + in the range 0-5000 cm-1, including explicit treatment of the high-resolution vibrational transitions, the low-resolution hole-transfer absorption centered at 2700 cm-1, and the resonance with the SHOMO to HOMO transition at 2200 cm-1 that resolve the issues concerning the nature of P + . The description of the vibrational aspects of the problem were taken from results of previous density-functional calculations, and a qualitatively realistic large number of vibrational modes (50 antisymmetric and 18-20 symmetric) were included. To facilitate the calculations, a new representation of the vibronic-coupling Hamiltonian for intervalence hole-transfer or electron-transfer problems is introduced, allowing the spectrum to be simulated efficiently using only up to 4x10 9 vibronic basis functions and leading also to new general analytical relationships. Observed spectra are fitted using seven adjustable chemical parameters describing the interactions between the four electronic states involved. The resulting fits provide unique descriptions of the parameters that are insensitive to the source of the observed spectrum or the nature of the symmetric modes used in the model, and all fitted parameters are found to be close in value to those from independent estimates. We determine the electronic coupling, antisymmetric-mode reorganization energy, and redox asymmetry to be J=0.126±0.002 eV, λ=0.139±0.003 eV, and E 0 =0.069±0.002 eV, respectively. Our description forms the basis of understanding for a wide range of other properties observed for Rhodobacter sphaeroides mutants, as well as the properties of the

  13. Determination of the transfer function for optical surface topography measuring instruments—a review

    International Nuclear Information System (INIS)

    Foreman, Matthew R; Török, Peter; Giusca, Claudiu L; Leach, Richard K; Coupland, Jeremy M

    2013-01-01

    A significant number of areal surface topography measuring instruments, largely based on optical techniques, are commercially available. However, implementation of optical instrumentation into production is currently difficult due to the lack of understanding of the complex interaction between the light and the component surface. Studying the optical transfer function of the instrument can help address this issue. Here a review is given of techniques for the measurement of optical transfer functions. Starting from the basis of a spatially coherent, monochromatic confocal scanning imaging system, the theory of optical transfer functions in three-dimensional (3D) imaging is presented. Further generalizations are reviewed allowing the extension of the theory to the description of conventional and interferometric 3D imaging systems. Polychromatic transfer functions and surface topography measurements are also discussed. Following presentation of theoretical results, experimental methods to measure the optical transfer function of each class of system are presented, with a focus on suitable methods for the establishment of calibration standards in 3D imaging and surface topography measurements. (topical review)

  14. Photoneutron spectrum measured with Bonner Spheres in Planetary method mode

    Energy Technology Data Exchange (ETDEWEB)

    Benites R, J. [Centro Estatal de Cancerologia de Nayarit, Servicio de Seguridad Radiologica, Calz. de la Cruz 118 Sur, 63000 Tepic, Nayarit (Mexico); Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Apdo. Postal 336, 98000 Zacatecas (Mexico); Velazquez F, J., E-mail: jlbenitesr@prodigy.net.mx [Universidad Autonoma de Nayarit, Posgrado en Ciencias Biologico Agropecuarias, Carretera Tepic-Compostela Km 9, 63780 Jalisco-Nayarit (Mexico)

    2012-10-15

    We measured the spectrum of photoneutrons at 100 cm isocenter linear accelerator (Linac) Varian ix operating at 15 MV Bremsstrahlung mode. In this process was used a radiation field of 20 x 20 cm{sup 2} at a depth of 5 cm in a solid water phantom with dimensions of 30 x 30 x 15 cm{sup 3}. The measurement was performed with a system using it Bonner Spheres spectrometric method Planetary mode. As neutron detector of the spectrometer is used thermoluminescent dosimeters pairs of type 600 and 700. (Author)

  15. Photoneutron spectrum measured with Bonner Spheres in Planetary method mode

    International Nuclear Information System (INIS)

    Benites R, J.; Vega C, H. R.; Velazquez F, J.

    2012-10-01

    We measured the spectrum of photoneutrons at 100 cm isocenter linear accelerator (Linac) Varian ix operating at 15 MV Bremsstrahlung mode. In this process was used a radiation field of 20 x 20 cm 2 at a depth of 5 cm in a solid water phantom with dimensions of 30 x 30 x 15 cm 3 . The measurement was performed with a system using it Bonner Spheres spectrometric method Planetary mode. As neutron detector of the spectrometer is used thermoluminescent dosimeters pairs of type 600 and 700. (Author)

  16. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    Science.gov (United States)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  17. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2018-05-01

    Full Text Available The transfer impedance is a very important parameter of a beam position monitor (BPM which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables. This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  18. A new energy transfer channel from carotenoids to chlorophylls in purple bacteria.

    Science.gov (United States)

    Feng, Jin; Tseng, Chi-Wei; Chen, Tingwei; Leng, Xia; Yin, Huabing; Cheng, Yuan-Chung; Rohlfing, Michael; Ma, Yuchen

    2017-07-10

    It is unclear whether there is an intermediate dark state between the S 2 and S 1 states of carotenoids. Previous two-dimensional electronic spectroscopy measurements support its existence and its involvement in the energy transfer from carotenoids to chlorophylls, but there is still considerable debate on the origin of this dark state and how it regulates the energy transfer process. Here we use ab initio calculations on excited-state dynamics and simulated two-dimensional electronic spectrum of carotenoids from purple bacteria to provide evidence supporting that the dark state may be assigned to a new A g + state. Our calculations also indicate that groups on the conjugation backbone of carotenoids may substantially affect the excited-state levels and the energy transfer process. These results contribute to a better understanding of carotenoid excited states.Carotenoids harvest energy from light and transfer it to chlorophylls during photosynthesis. Here, Feng et al. perform ab initio calculations on excited-state dynamics and simulated 2D electronic spectrum of carotenoids, supporting the existence of a new excited state in carotenoids.

  19. Measured and Predicted Variations in Fast Neutron Spectrum when Penetrating Laminated Fe-D{sub 2}O

    Energy Technology Data Exchange (ETDEWEB)

    Aalto, E; Sandlin, R; Fraeki, R

    1965-09-15

    Variations of the fast neutron spectrum in thin regions of alternating Fe and D{sub O} have been studied using threshold detectors (ln(n, n' ), S(n, p), Al(n, {alpha})). The results have been compared to those calculated by two shielding codes (NRN and RASH D) of multigroup removal-diffusion type. The absolute fast spectrum calculated in our rather complicated configurations was found to agree with measurements within the same accuracy (a factor of two) as did the thermal flux. The calculated spectrum is slightly harder than the measured one, but the detailed variations (covering the range 1:5) in the form of the spectrum when penetrating Fe agree with observations to within 15-20 %. In and Al activities were found to be proportional to the integrated flux over 1 MeV throughout the whole configuration, while S showed the least proportionality.

  20. Rotational temperature measurement of NO gas using two-photon excitation spectrum

    Science.gov (United States)

    Ozaki, Tadao; Matsui, Yoshihiko; Ohsawa, Toshihiko

    1981-04-01

    The rotational temperature of nitric oxide gas has been measured by means of a single-beam two-photon excitation spectrum method using a pulsed continuously tunable dye laser. The nitric oxide gas was enclosed at about 40 Torr in a quartz cell which was put in an electric oven. The NO γ (0-0) band and R11+Q21 branches were used to obtain the two-photon excitation spectrum. The rotational temperatures were determined using the fact that molecules are distributed in the rotational levels according to the Boltzmann law. The temperature range was from room temperature to about 470 K. Observed temperatures were in good agreement with cell temperatures which were obtained by using a thermocouple.

  1. Unbiased contaminant removal for 3D galaxy power spectrum measurements

    Science.gov (United States)

    Kalus, B.; Percival, W. J.; Bacon, D. J.; Samushia, L.

    2016-11-01

    We assess and develop techniques to remove contaminants when calculating the 3D galaxy power spectrum. We separate the process into three separate stages: (I) removing the contaminant signal, (II) estimating the uncontaminated cosmological power spectrum and (III) debiasing the resulting estimates. For (I), we show that removing the best-fitting contaminant (mode subtraction) and setting the contaminated components of the covariance to be infinite (mode deprojection) are mathematically equivalent. For (II), performing a quadratic maximum likelihood (QML) estimate after mode deprojection gives an optimal unbiased solution, although it requires the manipulation of large N_mode^2 matrices (Nmode being the total number of modes), which is unfeasible for recent 3D galaxy surveys. Measuring a binned average of the modes for (II) as proposed by Feldman, Kaiser & Peacock (FKP) is faster and simpler, but is sub-optimal and gives rise to a biased solution. We present a method to debias the resulting FKP measurements that does not require any large matrix calculations. We argue that the sub-optimality of the FKP estimator compared with the QML estimator, caused by contaminants, is less severe than that commonly ignored due to the survey window.

  2. Measuring the Binary Black Hole Mass Spectrum with an Astrophysically Motivated Parameterization

    Science.gov (United States)

    Talbot, Colm; Thrane, Eric

    2018-04-01

    Gravitational-wave detections have revealed a previously unknown population of stellar mass black holes with masses above 20 M ⊙. These observations provide a new way to test models of stellar evolution for massive stars. By considering the astrophysical processes likely to determine the shape of the binary black hole mass spectrum, we construct a parameterized model to capture key spectral features that relate gravitational-wave data to theoretical stellar astrophysics. In particular, we model the signature of pulsational pair-instability supernovae, which are expected to cause all stars with initial mass 100 M ⊙ ≲ M ≲ 150 M ⊙ to form ∼40 M ⊙ black holes. This would cause a cutoff in the black hole mass spectrum along with an excess of black holes near 40 M ⊙. We carry out a simulated data study to illustrate some of the stellar physics that can be inferred using gravitational-wave measurements of binary black holes and demonstrate several such inferences that might be made in the near future. First, we measure the minimum and maximum stellar black hole mass. Second, we infer the presence of a peak due to pair-instability supernovae. Third, we measure the distribution of black hole mass ratios. Finally, we show how inadequate models of the black hole mass spectrum lead to biased estimates of the merger rate and the amplitude of the stochastic gravitational-wave background.

  3. A Martian PFS average spectrum: Comparison with ISO SWS

    Science.gov (United States)

    Formisano, V.; Encrenaz, T.; Fonti, S.; Giuranna, M.; Grassi, D.; Hirsh, H.; Khatuntsev, I.; Ignatiev, N.; Lellouch, E.; Maturilli, A.; Moroz, V.; Orleanski, P.; Piccioni, G.; Rataj, M.; Saggin, B.; Zasova, L.

    2005-08-01

    The evaluation of the planetary Fourier spectrometer performance at Mars is presented by comparing an average spectrum with the ISO spectrum published by Lellouch et al. [2000. Planet. Space Sci. 48, 1393.]. First, the average conditions of Mars atmosphere are compared, then the mixing ratios of the major gases are evaluated. Major and minor bands of CO 2 are compared, from the point of view of features characteristics and bands depth. The spectral resolution is also compared using several solar lines. The result indicates that PFS radiance is valid to better than 1% in the wavenumber range 1800-4200 cm -1 for the average spectrum considered (1680 measurements). The PFS monochromatic transfer function generates an overshooting on the left-hand side of strong narrow lines (solar or atmospheric). The spectral resolution of PFS is of the order of 1.3 cm -1 or better. A large number of narrow features to be identified are discovered.

  4. Experimental measurement of neutron spectrum in the reflector of a light water reactor

    International Nuclear Information System (INIS)

    Brethe, P.

    1963-09-01

    1. Thermal neutrons: The temperature of the thermal neutron spectrum was calculated using Au-Lu foils. This temperature varies from 300 deg. K (temperature of the moderator) at 30 cm of the core to 350 deg. K in a hole of the core. 2. Slowing down of neutron: Four resonance detectors have been used (Au, In, Co, Mn). We can write a 1/E form of the spectrum. The linking up energy E M between thermal neutron spectrum and slowing down spectrum is about 0.23 eV and is free from the Maxwell spectrum temperature. The decrease of slowing down flux regarding thermal flux, farther from the core, has been showed. 3. Fast neutrons: We used 3 threshold detectors (Ni, Al, Mg). We supposed a E 1/2 e -βE from of the spectrum above 3 MeV. The values of β are in a range from 0.775, at the centre of the core and in a loop-hole, to 0,64 at about 30 cm of the core. 4. Continuous shape of the spectrum: The following interpolations give useful informations between the field where measurements have been made: between 340 eV and 10 keV: 1/E form between 10 keV and 330 keV: 1/(E σ S (E)) form (σ S (E) elastic scattering section on hydrogen) between 330 keV and 3 MeV: calculated form by the moments method (ref. BSR). (author) [fr

  5. PROBING THE INFLATON: SMALL-SCALE POWER SPECTRUM CONSTRAINTS FROM MEASUREMENTS OF THE COSMIC MICROWAVE BACKGROUND ENERGY SPECTRUM

    International Nuclear Information System (INIS)

    Chluba, Jens; Erickcek, Adrienne L.; Ben-Dayan, Ido

    2012-01-01

    In the early universe, energy stored in small-scale density perturbations is quickly dissipated by Silk damping, a process that inevitably generates μ- and y-type spectral distortions of the cosmic microwave background (CMB). These spectral distortions depend on the shape and amplitude of the primordial power spectrum at wavenumbers k ∼ 4 Mpc –1 . Here, we study constraints on the primordial power spectrum derived from COBE/FIRAS and forecasted for PIXIE. We show that measurements of μ and y impose strong bounds on the integrated small-scale power, and we demonstrate how to compute these constraints using k-space window functions that account for the effects of thermalization and dissipation physics. We show that COBE/FIRAS places a robust upper limit on the amplitude of the small-scale power spectrum. This limit is about three orders of magnitude stronger than the one derived from primordial black holes in the same scale range. Furthermore, this limit could be improved by another three orders of magnitude with PIXIE, potentially opening up a new window to early universe physics. To illustrate the power of these constraints, we consider several generic models for the small-scale power spectrum predicted by different inflation scenarios, including running-mass inflation models and inflation scenarios with episodes of particle production. PIXIE could place very tight constraints on these scenarios, potentially even ruling out running-mass inflation models if no distortion is detected. We also show that inflation models with sub-Planckian field excursion that generate detectable tensor perturbations should simultaneously produce a large CMB spectral distortion, a link that could potentially be established with PIXIE.

  6. Measurement of Two-Phase Flow and Heat Transfer Parameters using Infrared Thermometry

    Science.gov (United States)

    Kim, Tae-Hoon; Kommer, Eric; Dessiatoun, Serguei; Kim, Jungho

    2012-01-01

    A novel technique to measure heat transfer and liquid film thickness distributions over relatively large areas for two-phase flow and heat transfer phenomena using infrared (IR)thermometry is described. IR thermometry is an established technology that can be used to measure temperatures when optical access to the surface is available in the wavelengths of interest. In this work, a midwave IR camera (3.6-5.1 microns) is used to determine the temperature distribution within a multilayer consisting of a silicon substrate coated with a thin insulator. Since silicon is largely transparent to IR radiation, the temperature of the inner and outer walls of the multilayer can be measured by coating selected areas with a thin, IR opaque film. If the fluid used is also partially transparent to IR, the flow can be visualized and the liquid film thickness can be measured. The theoretical basis for the technique is given along with a description of the test apparatus and data reduction procedure. The technique is demonstrated by determining the heat transfer coefficient distributions produced by droplet evaporation and flow boiling heat transfer.

  7. Mass transfer effects in hygroscopic measurements of aerosol particles

    Directory of Open Access Journals (Sweden)

    M. N. Chan

    2005-01-01

    Full Text Available The tandem differential mobility analyzer (TDMA has been widely utilized to measure the hygroscopicity of laboratory-generated and atmospheric submicrometer particles. An important concern in investigating the hygroscopicity of the particles is if the particles have attained equilibrium state in the measurements. We present a literature survey to investigate the mass transfer effects in hygroscopicity measurements. In most TDMA studies, a residence time in the order of seconds is used for humidification (or dehumidification. NaCl and (NH42SO4 particles are usually used to verify the equilibrium measurements during this residence time, which is presumed to be sufficient for other particles. There have been observations that not all types of submicrometer particles, including atmospheric particles, attain their equilibrium sizes within this time scale. We recommend that experimentation with different residence times be conducted and that the residence time should be explicitly stated in future TDMA measurements. Mass transfer effects may also exist in the measurements of other properties related to the water uptake of atmospheric particles such as relative humidity dependent light scattering coefficients and cloud condensation nuclei activity.

  8. An absolute measurement of 252Cf prompt fission neutron spectrum at low energy range

    International Nuclear Information System (INIS)

    Lajtai, A.; Dyachenko, P.P.; Kutzaeva, L.S.; Kononov, V.N.; Androsenko, P.A.; Androsenko, A.A.

    1983-01-01

    Prompt neutron energy spectrum at low energies (25 keV 252 Cf spontaneous fission has been measured with a time-of-flight technique on a 30 cm flight-path. Ionization chamber and lithium-glass were used as fission fragment and neutron detectors, respectively. Lithium glasses of NE-912 (containing 6 Li) and of NE-913 (containing 7 Li) 45 mm in diameter and 9.5 mm in thickness have been employed alternatively, for the registration of fission neutrons and gammas. For the correct determination of the multiscattering effects - the main difficulty of the low energy neutron spectrum measurements - a special geometry for the neutron detector was used. Special attention was paid also to the determination of the absolute efficiency of the neutron detector. The real response function of the spectrometer was determined by a Monte-Carlo calculation. The scattering material content of the ionization chamber containing a 252 Cf source was minimized. As a result of this measurement a prompt fission neutron spectrum of Maxwell type with a T=1.42 MeV parameter was obtained at this low energy range. We did not find any neutron excess or irregularities over the Maxwellian. (author)

  9. Development and testing of emergency department patient transfer communication measures.

    Science.gov (United States)

    Klingner, Jill; Moscovice, Ira

    2012-01-01

    Communication problems are a major contributing factor to adverse events in hospitals.(1) The contextual environment in small rural hospitals increases the importance of emergency department (ED) patient transfer communication quality. This study addresses the communication problems through the development and testing of ED quality measurement of interfacility patient transfer communication. Input from existing measures, measurement and health care delivery experts, as well as hospital frontline staff was used to design and modify ED quality measures. Three field tests were conducted to determine the feasibility of data collection and the effectiveness of different training methods and types of partnerships. Measures were evaluated based on their prevalence, ease of data collection, and usefulness for internal and external improvement. It is feasible to collect ED quality measure data. Different data sources, data collection, and data entry methods, training and partners can be used to examine hospital ED quality. There is significant room for improvement in the communication of patient information between health care facilities. Current health care reform efforts highlight the importance of clear communication between organizations held accountable for patient safety and outcomes. The patient transfer communication measures have been tested in a wide range of rural settings and have been vetted nationally. They have been endorsed by the National Quality Forum, are included in the National Quality Measurement Clearinghouse supported by the Agency for Health Care Research and Quality (AHRQ), and are under consideration by the Centers for Medicare and Medicaid Services for future payment determinations beginning in calendar year 2013. © 2011 National Rural Health Association.

  10. Program controlled system for measuring and monitoring the electron coherent radiation spectrum of Yerevan synchrotron

    International Nuclear Information System (INIS)

    Adamyan, F.V.; Vartapetyan, G.A.; Galumyan, P.I.

    1980-01-01

    An automatic system for measurement, processing and control of energy spectrum of polarized photons realized at the Yerevan electron synchrotron is described. For measuring energy spectra of intensive high energy photon beams a pair spectrometer is used which comprises an aluminium target-converter, an analizing magnet and 2 telescopes of scintillation counters for electron-positron pairs registration. the procedure of spectra measurement by the pair spectrometer is reduced to determining the converted e + e - pairs yield at certain values of the H field intensity of the analizing magnet. An algorithm of the data express-processing for operative monitoring of peak energy stability of electron coherent radiation spectrum is given. The spectra measurement results obtained under real experimental conditions are presented

  11. Selective optical contacting for solar spectrum management

    Science.gov (United States)

    Yang, Jianfeng; Chen, Weijian; Wang, Bo; Zhang, Zhilong; Huang, Shujuan; Shrestha, Santosh; Wen, Xiaoming; Patterson, Robert; Conibeer, Gavin

    2017-02-01

    Solar spectrum management using up/down conversion is an important method to improve the photovoltaic energy conversion efficiency. It asks for a monochromatic luminescence absorption at the band edge of the photovoltaic device to reduce both the sub-band-gap and over-band-gap energy losses. Here, we demonstrate an energy selective optical contacting concept to improve the luminescence transfer efficiency for spectrum management. By increasing both the luminescence emission and re-absorption ability through photonic resonance, an efficient photon transfer channel could be established between the luminescence emitter and the photovoltaic component in a near-field region. This concept is not only able to compensate the insufficient band edge absorption ability of the photovoltaic device, but also to break the far-field limitation of luminescence radiation. The energy selection on the optical spectrum naturally imposed by the mode resonance is also helpful to improve the monochromaticity of the luminescence yield. In this paper, a photonic crystal cavity is used to realize the optical contacting concept between a thin silicon film and spectrum converter. The optical power and photon flux transferred between different components are calculated analytically using the electromagnetic Green's function. The corresponding radiative dipole moment is estimated by the fluctuation-dissipation theorem. The example shows an over 80 times enhancement in the luminescence absorbance by the silicon layer, illustrating the great potential of this concept to be applied on nano-structured photovoltaic devices.

  12. Spectrum of quantum transfer matrices via classical many-body systems

    Energy Technology Data Exchange (ETDEWEB)

    Gorsky, A. [ITEP,Bolshaya Cheremushkinskaya str. 25, 117218, Moscow (Russian Federation); MIPT,Inststitutskii per. 9, 141700, Dolgoprudny, Moscow region (Russian Federation); Zabrodin, A. [ITEP,Bolshaya Cheremushkinskaya str. 25, 117218, Moscow (Russian Federation); MIPT,Inststitutskii per. 9, 141700, Dolgoprudny, Moscow region (Russian Federation); Institute of Biochemical Physics,Kosygina str. 4, 119991, Moscow (Russian Federation); National Research University Higher School of Economics,Myasnitskaya str. 20, 101000, Moscow (Russian Federation); Zotov, A. [ITEP,Bolshaya Cheremushkinskaya str. 25, 117218, Moscow (Russian Federation); MIPT,Inststitutskii per. 9, 141700, Dolgoprudny, Moscow region (Russian Federation); Steklov Mathematical Institute, RAS,Gubkina str. 8, 119991, Moscow (Russian Federation)

    2014-01-15

    In this paper we clarify the relationship between inhomogeneous quantum spin chains and classical integrable many-body systems. It provides an alternative (to the nested Bethe ansatz) method for computation of spectra of the spin chains. Namely, the spectrum of the quantum transfer matrix for the inhomogeneous gl{sub n}-invariant XXX spin chain on N sites with twisted boundary conditions can be found in terms of velocities of particles in the rational N-body Ruijsenaars-Schneider model. The possible values of the velocities are to be found from intersection points of two Lagrangian submanifolds in the phase space of the classical model. One of them is the Lagrangian hyperplane corresponding to fixed coordinates of all N particles and the other one is an N-dimensional Lagrangian submanifold obtained by fixing levels of N classical Hamiltonians in involution. The latter are determined by eigenvalues of the twist matrix. To support this picture, we give a direct proof that the eigenvalues of the Lax matrix for the classical Ruijsenaars-Schneider model, where velocities of particles are substituted by eigenvalues of the spin chain Hamiltonians, calculated through the Bethe equations, coincide with eigenvalues of the twist matrix, with certain multiplicities. We also prove a similar statement for the gl{sub n} Gaudin model with N marked points (on the quantum side) and the Calogero-Moser system with N particles (on the classical side). The realization of the results obtained in terms of branes and supersymmetric gauge theories is also discussed.

  13. Photoinduced electron transfer process on emission spectrum of N,N‧-bis(salicylidene)-1,2-phenylenediamine as a Mg2+ cation chemosensor: A first principle DFT and TDDFT study

    Science.gov (United States)

    Taherpour, Avat (Arman); Jamshidi, Morteza; Rezaei, Omid; Belverdi, Ali Rezaei

    2018-06-01

    The electronic and optical properties of N,N‧-bis(salicylidene)-1,2-phenylenediamine (SPDA) ligand were studied as a chemical sensor of Mg2+ cation in two solvents (water and DMSO) using the ab initio theory through Density Functional Theory (DFT) and Time Dependent Density Functional theory (TDDFT) methods. The results show that the SPDA ligand has a high ability for chemical sensing of Mg2+. The results has also represented that HOMO-LUMO energy gap decreases 0.941 eV after the complex formation between SPDA and Mg2+. In addition, obvious changes are found in the UV-Vis absorption spectrum, optical analyses SPDA ligand and [SPDA.Mg]2+ complex, which it has the capability of detecting Mg2+ via the adsorptive UV-Vis and colorimetric methods. Emission spectrum calculations and photoinduced electron transfer (PET) process in water solution shows different wavelength emission spectrum in amount of 4.6 nm. An analysis of NBO (natural bond orbital) data indicates tangible changes in the electron transfers data from the electron pairs of ligand to the conjugated system, both prior and subsequent to Mg2+addition.

  14. New Measurements and Calculations to Characterize the Caliban Pulsed Reactor Cavity Neutron Spectrum by the Foil Activation Method

    Energy Technology Data Exchange (ETDEWEB)

    Jacquet, X.; Casoli, P.; Authier, N.; Rousseau, G. [CEA, Centre de Valduc, 21120 Is-sur-Tille (France); Barsu, C. [Pl. de la fontaine, 25410 Corcelles-Ferrieres (France)

    2011-07-01

    Caliban is a cylindrical metallic core reactor mainly composed of uranium 235. It is operated by the Criticality and Neutron Science Research Laboratory located at the French Atomic Energy Commission research center in Valduc. As with other fast burst reactors, Caliban is used extensively for determining the responses of electronic parts or other objects and materials to neutron-induced displacements. Therefore, Caliban's irradiation characteristics, and especially its central cavity neutron spectrum, have to be very accurately evaluated. The foil activation method has been used in the past by the Criticality and Neutron Science Research Laboratory to evaluate the neutron spectrum of the different facilities it operated, and in particular to characterize the Caliban cavity spectrum. In order to strengthen and to improve our knowledge of the Caliban cavity neutron spectrum and to reduce the uncertainties associated with the available evaluations, new measurements have been performed on the reactor and interpreted by the foil activation method. A sensor set has been selected to sample adequately the studied spectrum. Experimental measured reaction rates have been compared to the results from UMG spectrum unfolding software and to values obtained with the activation code Fispact. Experimental and simulation results are overall in good agreement, although gaps exist for some sensors. UMG software has also been used to rebuild the Caliban cavity neutron spectrum from activation measurements. For this purpose, a default spectrum is needed, and one has been calculated with the Monte-Carlo transport code Tripoli 4 using the benchmarked Caliban description. (authors)

  15. C2 Swan spectrum used as a molecular pyrometer in transferred arc and the influence noise to signal ratio on the temperature values

    International Nuclear Information System (INIS)

    Nassar, H

    2014-01-01

    The C 2 Swan system molecular emission spectrum is frequently observed in arc plasmas containing hydrocarbons. The spectra emitted from 5 kw in the transferred arc reactor at atmospheric pressure by CH 4 /CO 2 /Ar mixture are recorded with the help of an optical system consisting of a linear CCD array coupled with 2m spectrometer. The rotational temperature of 4300±300 K is found from the experimental Abel inverted spectra in the arc center after a point-to-point comparison of the spectrum with a computer simulated one. The influence of the noise to signal ratio has been studied, if the noise to signal ratio is about 10% we found an error of 7% at temperature 3000 K and 10% at 6000 K.

  16. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  17. The analysis of results of comparison test for radionuclides measurement through γ spectrum analysis from 2007 to 2012

    International Nuclear Information System (INIS)

    Wu Jialong; He Jian; Sun Wei; Wang Yun

    2013-01-01

    In order to test the capability of radionuclides measurement through γ spectrum analysis and improve the ability of the technicians by inter-laboratory comparison test, Gansu Center for Disease Prevention and Control participated in the comparison test organized by China Center for Disease Prevention and Control continuously from 2007 to 2012. All of the measured values are within the scope of qualified, and the relative deviation of measured value in the entire comparison tests is range from -16.31% to 11.83%.The results show that the equipment for γ spectrum measurement works normally, the analysis methods used for radioactive nuclide measuring is correct and the data in issued test report is accurate and reliable. The ability of the γ spectrum analysis satisfies the requirements of China Metrology Accreditation and the occupational health technical service. (authors)

  18. Are Autistic Traits Measured Equivalently in Individuals with and without an Autism Spectrum Disorder? An Invariance Analysis of the Autism Spectrum Quotient Short Form

    Science.gov (United States)

    Murray, Aja L.; Booth, Tom; McKenzie, Karen; Kuenssberg, Renate; O'Donnell, Michael

    2014-01-01

    It is common to administer measures of autistic traits to those without autism spectrum disorders (ASDs) with, for example, the aim of understanding autistic personality characteristics in non-autistic individuals. Little research has examined the extent to which measures of autistic traits actually measure the same traits in the same way across…

  19. Indoor measurement of photovoltaic device characteristics at varying irradiance, temperature and spectrum for energy rating

    International Nuclear Information System (INIS)

    Bliss, M; Betts, T R; Gottschalg, R

    2010-01-01

    The first three-dimensional performance matrix for use in photovoltaic (PV) energy rating is reported utilizing a novel energy rating solar simulator based on LEDs. Device characteristics are measured indoors at varying irradiance (G), temperature (T) and spectrum (E). This opens the possibility for a more accurate measurement system for energy yield prediction of PV devices, especially for devices with high spectral dependence such as wide bandgap solar cells as they take into account spectral changes in the light. The main aspects of the LED-based solar simulator used are briefly described. A measurement method is developed and detailed in the paper, which takes into account the current imperfections in the achievable spectrum. Measurement results for a crystalline silicon solar cell are used to demonstrate the measurement approach. An uncertainty analysis of the measurement system is given, resulting in an overall absolute uncertainty of 4.3% (coverage factor k = 2) in maximum power measurements at 765 W m −2 irradiance with scope for further improvements

  20. Cosmic microwave background dipole spectrum measured by the COBE FIRAS instrument

    Science.gov (United States)

    Fixsen, D. J.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Isaacman, R. B.; Mather, J. C.; Meyer, S. S.; Noerdlinger, P. D.; Shafer, R. A.; Weiss, R.

    1994-01-01

    The Far-Infrared Absolute Spectrophotometer (FIRAS) instrument on the Cosmic Background Explorer (COBE) has determined the dipole spectrum of the cosmic microwave background radiation (CMBR) from 2 to 20/cm. For each frequency the signal is decomposed by fitting to a monopole, a dipole, and a Galactic template for approximately 60% of the sky. The overall dipole spectrum fits the derivative of a Planck function with an amplitude of 3.343 +/- 0.016 mK (95% confidence level), a temperature of 2.714 +/- 0.022 K (95% confidence level), and an rms deviation of 6 x 10(exp -9) ergs/sq cm/s/sr cm limited by a detector and cosmic-ray noise. The monopole temperature is consistent with that determined by direct measurement in the accompanying article by Mather et al.

  1. Radiative-Transfer Modeling of Spectra of Densely Packed Particulate Media

    Science.gov (United States)

    Ito, G.; Mishchenko, M. I.; Glotch, T. D.

    2017-12-01

    Remote sensing measurements over a wide range of wavelengths from both ground- and space-based platforms have provided a wealth of data regarding the surfaces and atmospheres of various solar system bodies. With proper interpretations, important properties, such as composition and particle size, can be inferred. However, proper interpretation of such datasets can often be difficult, especially for densely packed particulate media with particle sizes on the order of wavelength of light being used for remote sensing. Radiative transfer theory has often been applied to the study of densely packed particulate media like planetary regoliths and snow, but with difficulty, and here we continue to investigate radiative transfer modeling of spectra of densely packed media. We use the superposition T-matrix method to compute scattering properties of clusters of particles and capture the near-field effects important for dense packing. Then, the scattering parameters from the T-matrix computations are modified with the static structure factor correction, accounting for the dense packing of the clusters themselves. Using these corrected scattering parameters, reflectance (or emissivity via Kirchhoff's Law) is computed with the method of invariance imbedding solution to the radiative transfer equation. For this work we modeled the emissivity spectrum of the 3.3 µm particle size fraction of enstatite, representing some common mineralogical and particle size components of regoliths, in the mid-infrared wavelengths (5 - 50 µm). The modeled spectrum from the T-matrix method with static structure factor correction using moderate packing densities (filling factors of 0.1 - 0.2) produced better fits to the laboratory measurement of corresponding spectrum than the spectrum modeled by the equivalent method without static structure factor correction. Future work will test the method of the superposition T-matrix and static structure factor correction combination for larger particles

  2. Planetary method to measure the neutrons spectrum in lineal accelerators of medical use

    International Nuclear Information System (INIS)

    Vega C, H. R.; Benites R, J. L.

    2014-08-01

    A novel procedure to measure the neutrons spectrum originated in a lineal accelerator of medical use has been developed. The method uses a passive spectrometer of Bonner spheres. The main advantage of the method is that only requires of a single shot of the accelerator. When this is used around a lineal accelerator is necessary to operate it under the same conditions so many times like the spheres that contain the spectrometer, activity that consumes enough time. The developed procedure consists on situating all the spheres of the spectrometer at the same time and to realize the reading making a single shot. With this method the photo neutrons spectrum produced by a lineal accelerator Varian ix of 15 MV to 100 cm of the isocenter was determined, with the spectrum is determined the total flow and the ambient dose equivalent. (Author)

  3. Combined fit of spectrum and composition data as measured by the Pierre Auger Observatory

    OpenAIRE

    Aab, A.; Abreu, P.; Aglietta, M.; Samarai, I. Al; Albuquerque, I.F.M.; Allekotte, I.; Almela, A.; Castillo, J. Alvarez; Alvarez-Muñiz, J.; Anastasi, G.A.; Anchordoqui, L.; Andrada, B.; Andringa, S.; Aramo, C.; Arqueros, F.

    2017-01-01

    We present a combined fit of a simple astrophysical model of UHECR sources to both the energy spectrum and mass composition data measured by the Pierre Auger Observatory. The fit has been performed for energies above $5 \\cdot 10^{18}$ eV, i.e.~the region of the all-particle spectrum above the so-called "ankle" feature. The astrophysical model we adopted consists of identical sources uniformly distributed in a comoving volume, where nuclei are accelerated through a rigidity-dependent mechanism...

  4. The Atacama Cosmology Telescope: temperature and gravitational lensing power spectrum measurements from three seasons of data

    Energy Technology Data Exchange (ETDEWEB)

    Das, Sudeep [Argonne National Laboratory, 9700 S. Cass Ave., Lemont, IL 60439 (United States); Louis, Thibaut; Calabrese, Erminia; Dunkley, Joanna [Sub-department of Astrophysics, University of Oxford, Keble Road, Oxford, OX1 3RH (United Kingdom); Nolta, Michael R.; Bond, J Richard; Hajian, Amir; Hincks, Adam D. [Canadian Institute for Theoretical Astrophysics, University of Toronto, Toronto, ON, M5S 3H8 Canada (Canada); Addison, Graeme E.; Halpern, Mark [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z4 Canada (Canada); Battistelli, Elia S. [Department of Physics, University of Rome ' ' La Sapienza' ' , Piazzale Aldo Moro 5, I-00185 Rome (Italy); Crichton, Devin; Gralla, Megan [Dept. of Physics and Astronomy, The Johns Hopkins University, 3400 N. Charles St., Baltimore, MD 21218-2686 (United States); Devlin, Mark J.; Dicker, Simon [Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA, 19104 (United States); Dünner, Rolando [Departamento de Astronomía y Astrofísica, Facultad de Física, Pontificía Universidad Católica, Casilla 306, Santiago 22 (Chile); Fowler, Joseph W. [NIST Quantum Devices Group, 325 Broadway Mailcode 817.03, Boulder, CO, 80305 (United States); Hasselfield, Matthew; Hlozek, Renée [Department of Astrophysical Sciences, Peyton Hall, Princeton University, Princeton, NJ 08544 (United States); Hilton, Matt, E-mail: sudeepphys@gmail.com [Centre for Astronomy and Particle Theory, School of Physics and Astronomy, University of Nottingham, NG7 2RD (United Kingdom); and others

    2014-04-01

    We present the temperature power spectra of the cosmic microwave background (CMB) derived from the three seasons of data from the Atacama Cosmology Telescope (ACT) at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. We detect and correct for contamination due to the Galactic cirrus in our equatorial maps. We present the results of a number of tests for possible systematic error and conclude that any effects are not significant compared to the statistical errors we quote. Where they overlap, we cross-correlate the ACT and the South Pole Telescope (SPT) maps and show they are consistent. The measurements of higher-order peaks in the CMB power spectrum provide an additional test of the ΛCDM cosmological model, and help constrain extensions beyond the standard model. The small angular scale power spectrum also provides constraining power on the Sunyaev-Zel'dovich effects and extragalactic foregrounds. We also present a measurement of the CMB gravitational lensing convergence power spectrum at 4.6σ detection significance.

  5. The Atacama Cosmology Telescope: Temperature and Gravitational Lensing Power Spectrum Measurements from Three Seasons of Data

    Science.gov (United States)

    Das, Sudeep; Louis, Thibaut; Nolta, Michael R.; Addison, Graeme E.; Battisetti, Elia S.; Bond, J. Richard; Calabrese, Erminia; Crichton, Devin; Devlin, Mark J.; Dicker, Simon; hide

    2014-01-01

    We present the temperature power spectra of the cosmic microwave background (CMB) derived from the three seasons of data from the Atacama Cosmology Telescope (ACT) at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. We detect and correct for contamination due to the Galactic cirrus in our equatorial maps. We present the results of a number of tests for possible systematic error and conclude that any effects are not significant compared to the statistical errors we quote. Where they overlap, we cross-correlate the ACT and the South Pole Telescope (SPT) maps and show they are consistent. The measurements of higher-order peaks in the CMB power spectrum provide an additional test of the ?CDM cosmological model, and help constrain extensions beyond the standard model. The small angular scale power spectrum also provides constraining power on the Sunyaev-Zel'dovich effects and extragalactic foregrounds. We also present a measurement of the CMB gravitational lensing convergence power spectrum at 4.6s detection significance.

  6. The Atacama Cosmology Telescope: temperature and gravitational lensing power spectrum measurements from three seasons of data

    International Nuclear Information System (INIS)

    Das, Sudeep; Louis, Thibaut; Calabrese, Erminia; Dunkley, Joanna; Nolta, Michael R.; Bond, J Richard; Hajian, Amir; Hincks, Adam D.; Addison, Graeme E.; Halpern, Mark; Battistelli, Elia S.; Crichton, Devin; Gralla, Megan; Devlin, Mark J.; Dicker, Simon; Dünner, Rolando; Fowler, Joseph W.; Hasselfield, Matthew; Hlozek, Renée; Hilton, Matt

    2014-01-01

    We present the temperature power spectra of the cosmic microwave background (CMB) derived from the three seasons of data from the Atacama Cosmology Telescope (ACT) at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. We detect and correct for contamination due to the Galactic cirrus in our equatorial maps. We present the results of a number of tests for possible systematic error and conclude that any effects are not significant compared to the statistical errors we quote. Where they overlap, we cross-correlate the ACT and the South Pole Telescope (SPT) maps and show they are consistent. The measurements of higher-order peaks in the CMB power spectrum provide an additional test of the ΛCDM cosmological model, and help constrain extensions beyond the standard model. The small angular scale power spectrum also provides constraining power on the Sunyaev-Zel'dovich effects and extragalactic foregrounds. We also present a measurement of the CMB gravitational lensing convergence power spectrum at 4.6σ detection significance

  7. Cosmic ray spectrum, composition, and anisotropy measured with IceCube

    International Nuclear Information System (INIS)

    Tamburro, Alessio

    2014-01-01

    Analysis of cosmic ray surface data collected with the IceTop array of Cherenkov detectors at the South Pole provides an accurate measurement of the cosmic ray spectrum and its features in the “knee” region up to energies of about 1 EeV. IceTop is part of the IceCube Observatory that includes a deep-ice cubic kilometer detector that registers signals of penetrating muons and other particles. Surface and in-ice signals detected in coincidence provide clear insights into the nuclear composition of cosmic rays. IceCube already measured an increase of the average primary mass as a function of energy. We present preliminary results on both IceTop-only and coincident events analysis. Furthermore, we review the recent measurement of the cosmic ray anisotropy with IceCube

  8. Cosmic ray spectrum, composition, and anisotropy measured with IceCube

    Science.gov (United States)

    Tamburro, Alessio

    2014-04-01

    Analysis of cosmic ray surface data collected with the IceTop array of Cherenkov detectors at the South Pole provides an accurate measurement of the cosmic ray spectrum and its features in the "knee" region up to energies of about 1 EeV. IceTop is part of the IceCube Observatory that includes a deep-ice cubic kilometer detector that registers signals of penetrating muons and other particles. Surface and in-ice signals detected in coincidence provide clear insights into the nuclear composition of cosmic rays. IceCube already measured an increase of the average primary mass as a function of energy. We present preliminary results on both IceTop-only and coincident events analysis. Furthermore, we review the recent measurement of the cosmic ray anisotropy with IceCube.

  9. Measuring Reciprocity in High Functioning Children and Adolescents with Autism Spectrum Disorders

    Science.gov (United States)

    van Ommeren, Tineke Backer; Begeer, Sander; Scheeren, Anke M.; Koot, Hans M.

    2012-01-01

    Few instruments have been developed that measure impairments in reciprocity, a defining feature of autism. We introduce a new test assessing the quality of reciprocal behaviour: the interactive drawing test (IDT). Children and adolescents (n = 49) with and without high functioning autism spectrum disorders (HFASD) were invited to collaborate with…

  10. Final Report: Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Haggerty, Roy [Oregon State Univ., Corvallis, OR (United States); Day-Lewis, Fred [U.S. Geological Survey, Storrs, CT (United States); Singha, Kamini [Colorado School of Mines, Golden, CO (United States); Johnson, Timothy [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Binley, Andrew [Lancaster Univ. (United Kingdom); Lane, John [U.S. Geological Survey, Storrs, CT (United States)

    2014-03-20

    Mass transfer affects contaminant transport and is thought to control the efficiency of aquifer remediation at a number of sites within the Department of Energy (DOE) complex. An improved understanding of mass transfer is critical to meeting the enormous scientific and engineering challenges currently facing DOE. Informed design of site remedies and long-term stewardship of radionuclide-contaminated sites will require new cost-effective laboratory and field techniques to measure the parameters controlling mass transfer spatially and across a range of scales. In this project, we sought to capitalize on the geophysical signatures of mass transfer. Previous numerical modeling and pilot-scale field experiments suggested that mass transfer produces a geoelectrical signature—a hysteretic relation between sampled (mobile-domain) fluid conductivity and bulk (mobile + immobile) conductivity—over a range of scales relevant to aquifer remediation. In this work, we investigated the geoelectrical signature of mass transfer during tracer transport in a series of controlled experiments to determine the operation of controlling parameters, and also investigated the use of complex-resistivity (CR) as a means of quantifying mass transfer parameters in situ without tracer experiments. In an add-on component to our grant, we additionally considered nuclear magnetic resonance (NMR) to help parse mobile from immobile porosities. Including the NMR component, our revised study objectives were to: 1. Develop and demonstrate geophysical approaches to measure mass-transfer parameters spatially and over a range of scales, including the combination of electrical resistivity monitoring, tracer tests, complex resistivity, nuclear magnetic resonance, and materials characterization; and 2. Provide mass-transfer estimates for improved understanding of contaminant fate and transport at DOE sites, such as uranium transport at the Hanford 300 Area. To achieve our objectives, we implemented a 3

  11. Implications of the cosmic ray electron spectrum and anisotropy measured with Fermi-LAT

    Energy Technology Data Exchange (ETDEWEB)

    Di Bernardo, Giuseppe [Gothenburg Univ. (Sweden). Dept. of Physics; Evoli, Carmelo [SISSA, Trieste (Italy); Gaggero, Daniele; Grasso, Dario [Pisa Univ. (Italy). Dipt. die Fisica; INFN, Pisa (Italy); Maccione, Luca [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Mazziotta, Mario Nicola [Istituto Nazionale di Fisica Nucleare, Bari (Italy)

    2010-11-15

    The Fermi Large Area Telescope (LAT) collaboration recently released the updated results of the measurement of the cosmic ray electron (CRE) spectrum and published its first constraints on the CRE anisotropy. With respect to the previous Fermi-LAT results, the CRE spectrum measurement was extended down from 20 to 7 GeV, thus providing a better lever arm to discriminate theoretical models. Here we show that the new data strengthen the evidence for the presence of two distinct electron and positron spectral components. Furthermore, we show that under such hypothesis most relevant CRE and positron data sets are remarkably well reproduced. Consistent fits of cosmic-ray nuclei and antiproton data, which are crucial to validate the adopted propagation setup(s) and to fix the solar modulation potential, are obtained for the Kraichnan and plain-diffusion propagation setups, while the Kolmogorov one is disfavored. We then confirm that nearby pulsars are viable source candidates of the required e{sup {+-}} extra-component. In that case, we show that the predicted CRE anisotropy is compatible with Fermi-LAT constraints and that a positive detection should be at hand of that observatory. Models assuming that only nearby supernova remnants contribute to the high energy tail of the observed CRE spectrum are in contrast with anisotropy limits. (orig.)

  12. Comparison of RF spectrum prediction methods for dynamic spectrum access

    Science.gov (United States)

    Kovarskiy, Jacob A.; Martone, Anthony F.; Gallagher, Kyle A.; Sherbondy, Kelly D.; Narayanan, Ram M.

    2017-05-01

    Dynamic spectrum access (DSA) refers to the adaptive utilization of today's busy electromagnetic spectrum. Cognitive radio/radar technologies require DSA to intelligently transmit and receive information in changing environments. Predicting radio frequency (RF) activity reduces sensing time and energy consumption for identifying usable spectrum. Typical spectrum prediction methods involve modeling spectral statistics with Hidden Markov Models (HMM) or various neural network structures. HMMs describe the time-varying state probabilities of Markov processes as a dynamic Bayesian network. Neural Networks model biological brain neuron connections to perform a wide range of complex and often non-linear computations. This work compares HMM, Multilayer Perceptron (MLP), and Recurrent Neural Network (RNN) algorithms and their ability to perform RF channel state prediction. Monte Carlo simulations on both measured and simulated spectrum data evaluate the performance of these algorithms. Generalizing spectrum occupancy as an alternating renewal process allows Poisson random variables to generate simulated data while energy detection determines the occupancy state of measured RF spectrum data for testing. The results suggest that neural networks achieve better prediction accuracy and prove more adaptable to changing spectral statistics than HMMs given sufficient training data.

  13. [Measurement of plasma parameters in slot microplasma by optical emission spectrum].

    Science.gov (United States)

    Dong, Li-Fang; Lü, Ying-Hui; Liu, Wei-Yuan; Yue, Han; Lu, Ning; Li, Xin-Chun

    2010-12-01

    Slot microplasma was generated in argon and air mixture by using dielectric barrier discharge device with two parallel water electrodes. The molecular vibrational temperature, molecular rotational temperature and average electron energy of the slot plasma were studied by optical emission spectrum. The molecular vibrational temperature was calculated using the second positive system of nitrogen molecules ( C3 pi(u) --> B3 pi(g)). The molecular rotational temperature was calculated using the first negative system of nitrogen molecular ions ( B 2sigma(u)+ --> X sigma(g)+). The relative intensities of the first negative system of nitrogen molecular ions (391.4 nm) and nitrogen molecules in the excitation level (337.1 nm) emission spectrum line were measured for studying the variations of electron energy. It was found that the molecular vibrational temperature, molecular rotational temperature and average electron energy decrease with gas pressure increasing.

  14. A Measurement of the Angular Power Spectrum of the CMB from l = 100 to 400

    Science.gov (United States)

    Miller, A. D.; Caldwell, R.; Devlin, M. J.; Dorwart, W. B.; Herbig, T.; Nolta, M. R.; Page, L. A.; Puchalla, J.; Torbet, E.; Tran, H. T.

    2000-05-01

    We report on a measurement of the angular spectrum of the CMB between l 100 and l 400 made at 144 GHz from Cerro Toco in the Chilean altiplano. When the new data are combined with previous data at 30 and 40 GHz, taken with the same instrument observing the same section of sky, we find: 1) a rise in the angular spectrum to a maximum with δ Tl 85 μ K at l 200 and a fall at l>300, thereby localizing the peak near l 200; and 2) that the anisotropy at l 200 has the spectrum of the CMB. Cosmological implications are discussed.

  15. Measurements of the Spectrum of Singly Ionized Argon between 320 and 520 nm

    International Nuclear Information System (INIS)

    Yang Zhao-Rui; Yuan Ping; Song Zhang-Yong; Xu Qiu-Mei; Yang Zhi-Hu

    2012-01-01

    We report beam-foil measurements of the spectrum for Ar II. Totally 56 lines are measured. Most of them are mainly ascribed to 3d-4p, 4s-4p, 4p-4d and 4p-5s resonance transitions. These spectral lines are identified, among which 16 lines are new and accurately measured. Analyses of the spectra are based on a comparison with the other experimental results and calculated values. (atomic and molecular physics)

  16. Automatic DGD and GVD compensation at 640 Gb/s based on scalar radio-frequency spectrum measurement

    DEFF Research Database (Denmark)

    Paquot, Yvan; Schröder, Jochen; Palushani, Evarist

    2013-01-01

    of separate GVD and DGD compensators using an impairment monitor based on an integrated all-optical radio-frequency (RF) spectrum analyzer. We show that low-bandwidth measurement of only a single tone in the RF spectrum is sufficient for automatic compensation for multiple degrees of freedom using...

  17. A spectroscopic transfer standard for accurate atmospheric CO measurements

    Science.gov (United States)

    Nwaboh, Javis A.; Li, Gang; Serdyukov, Anton; Werhahn, Olav; Ebert, Volker

    2016-04-01

    Atmospheric carbon monoxide (CO) is a precursor of essential climate variables and has an indirect effect for enhancing global warming. Accurate and reliable measurements of atmospheric CO concentration are becoming indispensable. WMO-GAW reports states a compatibility goal of ±2 ppb for atmospheric CO concentration measurements. Therefore, the EMRP-HIGHGAS (European metrology research program - high-impact greenhouse gases) project aims at developing spectroscopic transfer standards for CO concentration measurements to meet this goal. A spectroscopic transfer standard would provide results that are directly traceable to the SI, can be very useful for calibration of devices operating in the field, and could complement classical gas standards in the field where calibration gas mixtures in bottles often are not accurate, available or stable enough [1][2]. Here, we present our new direct tunable diode laser absorption spectroscopy (dTDLAS) sensor capable of performing absolute ("calibration free") CO concentration measurements, and being operated as a spectroscopic transfer standard. To achieve the compatibility goal stated by WMO for CO concentration measurements and ensure the traceability of the final concentration results, traceable spectral line data especially line intensities with appropriate uncertainties are needed. Therefore, we utilize our new high-resolution Fourier-transform infrared (FTIR) spectroscopy CO line data for the 2-0 band, with significantly reduced uncertainties, for the dTDLAS data evaluation. Further, we demonstrate the capability of our sensor for atmospheric CO measurements, discuss uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) principles and show that CO concentrations derived using the sensor, based on the TILSAM (traceable infrared laser spectroscopic amount fraction measurement) method, are in excellent agreement with gravimetric values. Acknowledgement Parts of this work have been

  18. Fast and Accurate Hybrid Stream PCRTMSOLAR Radiative Transfer Model for Reflected Solar Spectrum Simulation in the Cloudy Atmosphere

    Science.gov (United States)

    Yang, Qiguang; Liu, Xu; Wu, Wan; Kizer, Susan; Baize, Rosemary R.

    2016-01-01

    A hybrid stream PCRTM-SOLAR model has been proposed for fast and accurate radiative transfer simulation. It calculates the reflected solar (RS) radiances with a fast coarse way and then, with the help of a pre-saved matrix, transforms the results to obtain the desired high accurate RS spectrum. The methodology has been demonstrated with the hybrid stream discrete ordinate (HSDO) radiative transfer (RT) model. The HSDO method calculates the monochromatic radiances using a 4-stream discrete ordinate method, where only a small number of monochromatic radiances are simulated with both 4-stream and a larger N-stream (N = 16) discrete ordinate RT algorithm. The accuracy of the obtained channel radiance is comparable to the result from N-stream moderate resolution atmospheric transmission version 5 (MODTRAN5). The root-mean-square errors are usually less than 5x10(exp -4) mW/sq cm/sr/cm. The computational speed is three to four-orders of magnitude faster than the medium speed correlated-k option MODTRAN5. This method is very efficient to simulate thousands of RS spectra under multi-layer clouds/aerosols and solar radiation conditions for climate change study and numerical weather prediction applications.

  19. Measurement of heat transfers in cryogenic tank with several configurations

    International Nuclear Information System (INIS)

    Khemis, O.; Bessaieh, R.; Ait Ali, M.; Francois, M.X.

    2004-01-01

    The work presented here concerns the measurement of heat transfer in a cryogenic tank with several configurations. The experimental test incorporates the conductive heat in the neck, the convection heat transfers between the inner wall of the neck and the ascending vapor resulting from boiling, and the radiation heat transfers between the external envelope and the tank through a vacuum of 10 -8 mm Hg. An experimental prototype was produced in collaboration with the nuclear center of Orsay in France according to a didactic design, which takes into account the Wexler effect and the importance of the radiation compared to the conduction-convection heat transfer. The addition of a screen radiative ventilated with variable position on the neck (which can effectively replace several tens of floating screens), in order to find the optimal position, which minimizes the radiation flux, is presented in this paper

  20. Directly measuring mean and variance of infinite-spectrum observables such as the photon orbital angular momentum.

    Science.gov (United States)

    Piccirillo, Bruno; Slussarenko, Sergei; Marrucci, Lorenzo; Santamato, Enrico

    2015-10-19

    The standard method for experimentally determining the probability distribution of an observable in quantum mechanics is the measurement of the observable spectrum. However, for infinite-dimensional degrees of freedom, this approach would require ideally infinite or, more realistically, a very large number of measurements. Here we consider an alternative method which can yield the mean and variance of an observable of an infinite-dimensional system by measuring only a two-dimensional pointer weakly coupled with the system. In our demonstrative implementation, we determine both the mean and the variance of the orbital angular momentum of a light beam without acquiring the entire spectrum, but measuring the Stokes parameters of the optical polarization (acting as pointer), after the beam has suffered a suitable spin-orbit weak interaction. This example can provide a paradigm for a new class of useful weak quantum measurements.

  1. Measurement of Neutron Energy Spectrum Emitted by Cf-252 Source Using Time-of-Flight Method

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Cheol Ho; Son, Jaebum; Kim, Tae Hoon; Lee, Sangmin; Kim, Yong-Kyun [Hanyang University, Seoul (Korea, Republic of)

    2016-10-15

    The techniques proposed to detect the neutrons usually require the detection of a secondary recoiling nucleus in a scintillator (or other type of detector) to indicate the rare collision of a neutron with a nucleus. This is the same basic technique, in this case detection of a recoil proton that was used by Chadwick in the 1930 s to discover and identify the neutron and determine its mass. It is primary technique still used today for detection of fast neutron, which typically involves the use of a hydrogen based organic plastic or liquid scintillator coupled to a photo-multiplier tube. The light output from such scintillators is a function of the cross section and nuclear kinematics of the n + nucleus collision. With the exception of deuterated scintillators, the scintillator signal does not necessarily produce a distinct peak in the scintillator spectrum directly related to the incident neutron energy. Instead neutron time-of-flight (TOF) often must be utilized to determine the neutron energy, which requires generation of a prompt start signal from the nuclear source emitting the neutrons. This method takes advantage of the high number of prompt gamma rays. The Time-of-Flight method was used to measure neutron energy spectrum emitted by the Cf-252 neutron source. Plastic scintillator that has a superior discrimination ability of neutron and gamma-ray was used as a stop signal detector and liquid scintillator was used as a stat signal detector. In experiment, neutron and gamma-ray spectrum was firstly measured and discriminated using the TOF method. Secondly, neutron energy spectrum was obtained through spectrum analysis. Equation of neutron energy spectrum that was emitted by Cf-252 source using the Gaussian fitting was obtained.

  2. Direct measurement of the energy spectrum of an intense proton beam

    International Nuclear Information System (INIS)

    Leeper, R.J.; Lee, J.R.; Kissel, L.; Johnson, D.J.; Stygar, W.A.; Hebron, D.E.; Roose, L.D.

    1983-01-01

    A time-resolved magnetic spectrometer has been used to measure the energy spectrum of an intense (0.5 TW/cm 2 ) proton beam. A thin (2400 A) gold foil placed at the focus of an ion diode Rutherford scattered protons by 90 0 into the spectrometer, reducing the beam intensity to a level suitable for magnetic analysis. The scattered beam was collimated by two 1 mm diameter apertures separated by 12.3 cm. The collimated protons were deflected in a 12.7 cm diameter, 6.65 Kg samarium-cobalt permanent magnet. The deflected protons were recorded simultaneously on CR-39 and eight 1 mm 2 by 35 μm thick PIN diodes. A Monte Carlo computer code was used to calculate the sensitivity and resolution of the spectrometer. Data taken on Proto-I show a 150 keV to 250 keV wide proton energy spectrum at each instant in time

  3. Laboratory Measurements of Single-Particle Polarimetric Spectrum

    Science.gov (United States)

    Gritsevich, M.; Penttila, A.; Maconi, G.; Kassamakov, I.; Helander, P.; Puranen, T.; Salmi, A.; Hæggström, E.; Muinonen, K.

    2017-12-01

    Measuring scattering properties of different targets is important for material characterization, remote sensing applications, and for verifying theoretical results. Furthermore, there are usually simplifications made when we model targets and compute the scattering properties, e.g., ideal shape or constant optical parameters throughout the target material. Experimental studies help in understanding the link between the observed properties and computed results. Experimentally derived Mueller matrices of studied particles can be used as input for larger-scale scattering simulations, e.g., radiative transfer computations. This method allows to bypass the problem of using an idealized model for single-particle optical properties. While existing approaches offer ensemble- and orientation-averaged particle properties, our aim is to measure individual particles with controlled or known orientation. With the newly developed scatterometer, we aim to offer novel possibility to measure single, small (down to μm-scale) targets and their polarimetric spectra. This work presents an experimental setup that measures light scattered by a fixed small particle with dimensions ranging between micrometer and millimeter sizes. The goal of our setup is nondestructive characterization of such particles by measuring light of multiple wavelengths scattered in 360° in a horizontal plane by an ultrasonically levitating sample, whilst simultaneously controlling its 3D position and orientation. We describe the principles and design of our instrument and its calibration. We also present example measurements of real samples. This study was conducted under the support from the European Research Council, in the frame of the Advanced Grant project No. 320773 `Scattering and Absorption of Electromagnetic Waves in Particulate Media' (SAEMPL).

  4. Laser Sensing of Vegetation Based on Dual Spectrum Measurements of Reflection Coefficients

    Directory of Open Access Journals (Sweden)

    M. L. Belov

    2017-01-01

    Full Text Available Currently, a promising trend in remote sensing of environment is to monitor the vegetative cover: evaluate the productivity of agricultural crops; evaluate the moisture content of soils and the state of ecosystems; provide mapping the sites of bogging, desertification, drought, etc.; control the phases of vegetation of crops, etc.Development of monitoring systems for remote detection of vegetation sites being under unfavorable conditions (low or high temperature, excess or lack of water, soil salinity, disease, etc. is of relevance. Optical methods are the most effective for this task. These methods are based on the physical features of reflection spectra in the visible and near infrared spectral range for vegetation under unfavorable conditions and vegetation under normal conditions.One of the options of optoelectronic equipment for monitoring vegetation condition is laser equipment that allows remote sensing of vegetation from the aircraft and mapping of vegetation sites with abnormal (inactive periods of vegetation reflection spectra with a high degree of spatial resolution.The paper deals with development of a promising dual-spectrum method for laser remote sensing of vegetation. Using the experimentally measured reflection spectra of different vegetation types, mathematical modeling of probability for appropriate detection and false alarms to solve a problem of detecting the vegetation under unfavorable conditions (with abnormal reflection spectra is performed based on the results of dual-spectrum measurements of the reflection coefficient.In mathematical modeling, the lidar system was supposed to provide sensing at wavelengths of 0.532 μm and 0.85 μm. The noise of the measurement was supposed to be normal with zero mean value and mean-square value of 1% -10%.It is shown that the method of laser sensing of vegetation condition based on the results of dual-spectrum measurement of the reflection coefficient at wavelengths of 0.532 μm and 0

  5. A preliminary layout and PIC simulations of the time resolved beam energy spectrum measurement for DRAGON-I

    International Nuclear Information System (INIS)

    Liao Shuqing; Zhang Kaizhi; Shi Jingshui

    2010-01-01

    The time resolved beam energy spectrum for DRAGON-I can be measured with a new method which is named RBS (Rotating Beam in Solenoid). The beam energy spectrum is determined by measuring the beam rotation angle and its expansion width at the exit of DRAGON-I. The rotation beam is shaped by a slit at the exit of DRAGON-I, then rotated in the magnetic field of the solenoids and the resulted beamlet is measured by the Cherenkov screen. The beam motion in the solenoids is simulated by PARMELA and the relationships between the beam rotation angle's expansion width and the beam energy spread, emittance are discussed. The measurement error is also discussed in this paper. (authors)

  6. Heat transfer measurements of the 1983 kilauea lava flow.

    Science.gov (United States)

    Hardee, H C

    1983-10-07

    Convective heat flow measurements of a basaltic lava flow were made during the 1983 eruption of Kilauea volcano in Hawaii. Eight field measurements of induced natural convection were made, giving heat flux values that ranged from 1.78 to 8.09 kilowatts per square meter at lava temperatures of 1088 and 1128 degrees Celsius, respectively. These field measurements of convective heat flux at subliquidus temperatures agree with previous laboratory measurements in furnace-melted samples of molten lava, and are useful for predicting heat transfer in magma bodies and for estimating heat extraction rates for magma energy.

  7. A Method to Reconstruct the Solar-Induced Canopy Fluorescence Spectrum from Hyperspectral Measurements

    Directory of Open Access Journals (Sweden)

    Feng Zhao

    2014-10-01

    Full Text Available A method for canopy Fluorescence Spectrum Reconstruction (FSR is proposed in this study, which can be used to retrieve the solar-induced canopy fluorescence spectrum over the whole chlorophyll fluorescence emission region from 640–850 nm. Firstly, the radiance of the solar-induced chlorophyll fluorescence (Fs at five absorption lines of the solar spectrum was retrieved by a Spectral Fitting Method (SFM. The Singular Vector Decomposition (SVD technique was then used to extract three basis spectra from a training dataset simulated by the model SCOPE (Soil Canopy Observation, Photochemistry and Energy fluxes. Finally, these basis spectra were linearly combined to reconstruct the Fs spectrum, and the coefficients of them were determined by Weighted Linear Least Squares (WLLS fitting with the five retrieved Fs values. Results for simulated datasets indicate that the FSR method could accurately reconstruct the Fs spectra from hyperspectral measurements acquired by instruments of high Spectral Resolution (SR and Signal to Noise Ratio (SNR. The FSR method was also applied to an experimental dataset acquired in a diurnal experiment. The diurnal change of the reconstructed Fs spectra shows that the Fs radiance around noon was higher than that in the morning and afternoon, which is consistent with former studies. Finally, the potential and limitations of this method are discussed.

  8. Measurement and modeling of interface heat transfer coefficients

    International Nuclear Information System (INIS)

    Rollett, A.D.; Lewis, H.D.; Dunn, P.S.

    1985-01-01

    The results of preliminary work on the modeling and measurement of the heat transfer coefficients of metal/mold interfaces is reported. The system investigated is the casting of uranium in graphite molds. The motivation for the work is primarily to improve the accuracy of process modeling of prototype mold designs at the Los Alamos Foundry. The evolution in design of a suitable mold for unidirectional solidification is described, illustrating the value of simulating mold designs prior to use. Experiment indicated a heat transfer coefficient of 2 kW/m 2 /K both with and without superheat. It was possible to distinguish between solidification due to the mold and that due to radiative heat loss. This permitted an experimental estimate of the emissivity, epsilon = 0.2, of the solidified metal

  9. [Studies on measurement of oral mucosal color with non-contact spectrum colorimeter].

    Science.gov (United States)

    Ohata, Yohei

    2006-03-01

    Color inspection plays an important role in the diagnosis of oral mucosal lesions. However, it is sometimes difficult to diagnose by color, because color is always evaluated subjectively. In order to measure color objectively and quantitatively, we decided to use a newly developed spectrum colorimeter for the oral mucosa. To keep the same angle and distance, a special stick was utilized. Various experiments were performed and suitable conditions for accurate colorimetric measurement were decided, including room temperature with cooling fan, onset time of the device, calibration timing, and the angle between light and the measured surface. The reproducibility of this method was confirmed by measuring the color of the buccal mucosa in healthy persons.

  10. Extended-Spectrum β-Lactamase–Producing Enterobacteriaceae in Children: Old Foe, Emerging Threat

    Science.gov (United States)

    Lukac, Paul J.; Bonomo, Robert A.; Logan, Latania K.

    2015-01-01

    Extended-spectrum β-lactamase (ESBL)-producing Enterobacteriaceae present an ever-growing burden in the hospital and community settings, across all ages and demographics. Infections due to ESBL-containing pathogens continue to be associated with significant morbidity and mortality worldwide. With widespread empiric broad-spectrum β-lactam use creating selective pressure, and the resultant emergence of stable, rapidly proliferating ESBL-producing clones with continued horizontal gene transfer across genera, addressing this issue remains imperative. Although well characterized in adults, the epidemiology, risk factors, outcomes, therapies, and control measures for ESBL-producing bacteria are less appreciated in children. This analysis provides a brief summary of ESBL-producing Enterobacteriaceae in children, with a focus on recent clinical and molecular data regarding colonization and infection in nonoutbreak settings. PMID:25595742

  11. Measurement of diffractive scattering of photons with large momentum transfer at HERA

    International Nuclear Information System (INIS)

    Aaron, F.D.; Andreev, V.

    2008-09-01

    The first measurement of diffractive scattering of quasi-real photons with large momentum transfer γp → γY, where Y is the proton dissociative system, is made using the H1 detector at HERA. The measurement is performed for initial photon virtualities Q 2 2 . Cross sections are measured as a function of W, the incident photonproton centre of mass energy, and t, the square of the four-momentum transferred at the proton vertex, in the range 175 2 . The W dependence is well described by a model based on perturbative QCD using a leading logarithmic approximation of the BFKL evolution. The measured vertical stroke t vertical stroke dependence is harder than that predicted by the model and those observed in exclusive vector meson production. (orig.)

  12. Time-resolved UV-excited microarray reader for fluorescence energy transfer (FRET) measurements

    Science.gov (United States)

    Orellana, Adelina; Hokkanen, Ari P.; Pastinen, Tomi; Takkinen, Kristina; Soderlund, Hans

    2001-05-01

    Analytical systems based on immunochemistry are largely used in medical diagnostics and in biotechnology. There is a significant pressure to develop the present assay formats to become easier to use, faster, and less reagent consuming. Further developments towards high density array--like multianalyte measurement systems would be valuable. To this aim we have studied the applicability of fluorescence resonance energy transfer and time-resolved fluorescence resonance energy transfer in immunoassays on microspots and in microwells. We have used engineered recombinant antibodies detecting the pentameric protein CRP as a model analyte system, and tested different assay formats. We describe also the construction of a time-resolved scanning epifluorometer with which we could measure the FRET interaction between the slow fluorescence decay from europium chelates and its energy transfer to the rapidly decaying fluorophore Cy5.

  13. Measurements of integral cross sections in the californium-252 fission neutron spectrum

    International Nuclear Information System (INIS)

    Alberts, W.G.; Guenther, E.; Matzke, M.; Rassl, G.

    1977-01-01

    In a low-scattering arrangement cross sections averaged over the californium-252 spontaneous fission neutron spectrum were measured. The reactions 27 Al(n,α) 46 Ti, 47 Ti, 48 Ti(n,p), 54 Fe, 56 Fe(n,p), 58 Ni(n,p), 64 Zn(n,p), 115 In(n,n') were studied in order to obtain a consistent set of threshold detectors used in fast neutron flux density measurements. Overall uncertainties between 2 and 2.5% could be achieved; corrections due to neutron scattering in source and samples are discussed

  14. 31P magnetization transfer measurements of Pi→ATP flux in exercising human muscle.

    Science.gov (United States)

    Sleigh, Alison; Savage, David B; Williams, Guy B; Porter, David; Carpenter, T Adrian; Brindle, Kevin M; Kemp, Graham J

    2016-03-15

    Fundamental criticisms have been made over the use of (31)P magnetic resonance spectroscopy (MRS) magnetization transfer estimates of inorganic phosphate (Pi)→ATP flux (VPi-ATP) in human resting skeletal muscle for assessing mitochondrial function. Although the discrepancy in the magnitude of VPi-ATP is now acknowledged, little is known about its metabolic determinants. Here we use a novel protocol to measure VPi-ATP in human exercising muscle for the first time. Steady-state VPi-ATP was measured at rest and over a range of exercise intensities and compared with suprabasal oxidative ATP synthesis rates estimated from the initial rates of postexercise phosphocreatine resynthesis (VATP). We define a surplus Pi→ATP flux as the difference between VPi-ATP and VATP. The coupled reactions catalyzed by the glycolytic enzymes GAPDH and phosphoglycerate kinase (PGK) have been shown to catalyze measurable exchange between ATP and Pi in some systems and have been suggested to be responsible for this surplus flux. Surplus VPi-ATP did not change between rest and exercise, even though the concentrations of Pi and ADP, which are substrates for GAPDH and PGK, respectively, increased as expected. However, involvement of these enzymes is suggested by correlations between absolute and surplus Pi→ATP flux, both at rest and during exercise, and the intensity of the phosphomonoester peak in the (31)P NMR spectrum. This peak includes contributions from sugar phosphates in the glycolytic pathway, and changes in its intensity may indicate changes in downstream glycolytic intermediates, including 3-phosphoglycerate, which has been shown to influence the exchange between ATP and Pi catalyzed by GAPDH and PGK. Copyright © 2016 the American Physiological Society.

  15. Depression and Its Measurement in Verbal Adolescents and Adults with Autism Spectrum Disorder

    Science.gov (United States)

    Gotham, Katherine; Unruh, Kathryn; Lord, Catherine

    2015-01-01

    In a sample of 50 verbally fluent adolescents and adults with autism spectrum disorders (age: 16-31 years; verbal IQ: 72-140), we examined the pattern of response and associations between scores on common measures of depressive symptoms, participant characteristics, and clinical diagnosis of depressive disorders. Beck Depression Inventory--Second…

  16. Security camera resolution measurements: Horizontal TV lines versus modulation transfer function measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Birch, Gabriel Carisle [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Griffin, John Clark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    The horizontal television lines (HTVL) metric has been the primary quantity used by division 6000 related to camera resolution for high consequence security systems. This document shows HTVL measurements are fundamen- tally insufficient as a metric to determine camera resolution, and propose a quantitative, standards based methodology by measuring the camera system modulation transfer function (MTF), the most common and accepted metric of res- olution in the optical science community. Because HTVL calculations are easily misinterpreted or poorly defined, we present several scenarios in which HTVL is frequently reported, and discuss their problems. The MTF metric is discussed, and scenarios are presented with calculations showing the application of such a metric.

  17. Use of boron nitride for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements

    Science.gov (United States)

    Radulović, Vladimir; Trkov, Andrej; Jaćimović, Radojko; Gregoire, Gilles; Destouches, Christophe

    2016-12-01

    A recent experimental irradiation and measurement campaign using containers made from boron nitride (BN) at the Jožef Stefan Institute (JSI) TRIGA Mark II reactor in Ljubljana, Slovenia, has shown the applicability of BN for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements. The first part of the paper focuses on the determination of the transmission function of a BN container through Monte Carlo calculations and experimental measurements. The second part presents the process of tayloring the sensitivity of integral activation measurements to specific needs and a selection of suitable radiative capture reactions for neutron spectrum characterization in the epithermal range. A BN container used in our experiments and its qualitative effect on the neutron spectrum in the irradiation position employed is displayed in the Graphical abstract.

  18. A measurement by BOOMERANG of multiple peaks in the angular power spectrum of the cosmic microwave background

    Science.gov (United States)

    Netterfield, C. B.; Ade, P. A. R.; Bock, J. J.; Bond, J. R.; Borrill, J.; Boscaleri, A.; Coble, K.; Contaldi, C. R.; Crill, B. P.; Bernardis, P. de; hide

    2001-01-01

    This paper presents a measurement of the angular power spectrum of the Cosmic Microwave Background from l = 75 to l = 1025 (10' to 5 degrees) from a combined analysis of four 150 GHz channels in the BOOMERANG experiment. The spectrum contains multiple peaks and minima, as predicted by standard adiabatic-inflationary models in which the primordial plasma undergoes acoustic oscillations.

  19. Frequency spectrum might act as communication code between retina and visual cortex I.

    Science.gov (United States)

    Yang, Xu; Gong, Bo; Lu, Jian-Wei

    2015-01-01

    To explore changes and possible communication relationship of local potential signals recorded simultaneously from retina and visual cortex I (V1). Fourteen C57BL/6J mice were measured with pattern electroretinogram (PERG) and pattern visually evoked potential (PVEP) and fast Fourier transform has been used to analyze the frequency components of those signals. The amplitude of PERG and PVEP was measured at about 36.7 µV and 112.5 µV respectively and the dominant frequency of PERG and PVEP, however, stay unchanged and both signals do not have second, or otherwise, harmonic generation. The results suggested that retina encodes visual information in the way of frequency spectrum and then transfers it to primary visual cortex. The primary visual cortex accepts and deciphers the input visual information coded from retina. Frequency spectrum may act as communication code between retina and V1.

  20. Measurement of diffractive scattering of photons with large momentum transfer at HERA

    Science.gov (United States)

    H1 Collaboration; Aaron, F. D.; Alexa, C.; Andreev, V.; Antunovic, B.; Aplin, S.; Asmone, A.; Astvatsatourov, A.; Bacchetta, A.; Backovic, S.; Baghdasaryan, A.; Baranov, P.; Barrelet, E.; Bartel, W.; Beckingham, M.; Begzsuren, K.; Behnke, O.; Belousov, A.; Berger, N.; Bizot, J. C.; Boenig, M.-O.; Boudry, V.; Bozovic-Jelisavcic, I.; Bracinik, J.; Brandt, G.; Brinkmann, M.; Brisson, V.; Bruncko, D.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A. J.; Cantun Avila, K. B.; Cassol-Brunner, F.; Cerny, K.; Cerny, V.; Chekelian, V.; Cholewa, A.; Contreras, J. G.; Coughlan, J. A.; Cozzika, G.; Cvach, J.; Dainton, J. B.; Daum, K.; Deák, M.; de Boer, Y.; Delcourt, B.; Del Degan, M.; Delvax, J.; de Roeck, A.; de Wolf, E. A.; Diaconu, C.; Dodonov, V.; Dossanov, A.; Dubak, A.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eliseev, A.; Elsen, E.; Essenov, S.; Falkiewicz, A.; Faulkner, P. J. W.; Favart, L.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Finke, L.; Fleischer, M.; Fomenko, A.; Gabathuler, E.; Gayler, J.; Ghazaryan, S.; Glazov, A.; Glushkov, I.; Goerlich, L.; Goettlich, M.; Gogitidze, N.; Gouzevitch, M.; Grab, C.; Greenshaw, T.; Grell, B. R.; Grindhammer, G.; Habib, S.; Haidt, D.; Hansson, M.; Helebrant, C.; Henderson, R. C. W.; Henschel, H.; Herrera, G.; Hildebrandt, M.; Hiller, K. H.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Hreus, T.; Jacquet, M.; Janssen, M. E.; Janssen, X.; Jemanov, V.; Jönsson, L.; Johnson, D. P.; Jung, A. W.; Jung, H.; Kapichine, M.; Katzy, J.; Kenyon, I. R.; Kiesling, C.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knutsson, A.; Kogler, R.; Korbel, V.; Kostka, P.; Kraemer, M.; Krastev, K.; Kretzschmar, J.; Kropivnitskaya, A.; Krüger, K.; Kutak, K.; Landon, M. P. J.; Lange, W.; Laštovička-Medin, G.; Laycock, P.; Lebedev, A.; Leibenguth, G.; Lendermann, V.; Levonian, S.; Li, G.; Lipka, K.; Liptaj, A.; List, B.; List, J.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lucaci-Timoce, A.-I.; Lytkin, L.; Makankine, A.; Malinovski, E.; Marage, P.; Marti, Ll.; Martyn, H.-U.; Maxfield, S. J.; Mehta, A.; Meier, K.; Meyer, A. B.; Meyer, H.; Meyer, H.; Meyer, J.; Michels, V.; Mikocki, S.; Milcewicz-Mika, I.; Moreau, F.; Morozov, A.; Morris, J. V.; Mozer, M. U.; Mudrinic, M.; Müller, K.; Murín, P.; Nankov, K.; Naroska, B.; Naumann, Th.; Newman, P. R.; Niebuhr, C.; Nikiforov, A.; Nowak, G.; Nowak, K.; Nozicka, M.; Olivier, B.; Olsson, J. E.; Osman, S.; Ozerov, D.; Palichik, V.; Panagoulias, I.; Pandurovic, M.; Papadopoulou, Th.; Pascaud, C.; Patel, G. D.; Pejchal, O.; Peng, H.; Perez, E.; Petrukhin, A.; Picuric, I.; Piec, S.; Pitzl, D.; Plačakytė, R.; Polifka, R.; Povh, B.; Preda, T.; Radescu, V.; Rahmat, A. J.; Raicevic, N.; Raspiareza, A.; Ravdandorj, T.; Reimer, P.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rotaru, M.; Ruiz Tabasco, J. E.; Rurikova, Z.; Rusakov, S.; Salek, D.; Salvaire, F.; Sankey, D. P. C.; Sauter, M.; Sauvan, E.; Schmidt, S.; Schmitt, S.; Schmitz, C.; Schoeffel, L.; Schöning, A.; Schultz-Coulon, H.-C.; Sefkow, F.; Shaw-West, R. N.; Sheviakov, I.; Shtarkov, L. N.; Shushkevich, S.; Sloan, T.; Smiljanic, I.; Smirnov, P.; Soloviev, Y.; Sopicki, P.; South, D.; Spaskov, V.; Specka, A.; Staykova, Z.; Steder, M.; Stella, B.; Straumann, U.; Sunar, D.; Sykora, T.; Tchoulakov, V.; Thompson, G.; Thompson, P. D.; Toll, T.; Tomasz, F.; Tran, T. H.; Traynor, D.; Trinh, T. N.; Truöl, P.; Tsakov, I.; Tseepeldorj, B.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Urban, K.; Valkárová, A.; Vallée, C.; van Mechelen, P.; Vargas Trevino, A.; Vazdik, Y.; Vinokurova, S.; Volchinski, V.; Wegener, D.; Wessels, M.; Wissing, Ch.; Wünsch, E.; Yeganov, V.; Žáček, J.; Zálešák, J.; Zhang, Z.; Zhelezov, A.; Zhokin, A.; Zhu, Y. C.; Zimmermann, T.; Zohrabyan, H.; Zomer, F.

    2009-02-01

    The first measurement of diffractive scattering of quasi-real photons with large momentum transfer γp→γY, where Y is the proton dissociative system, is made using the H1 detector at HERA. The measurement is performed for initial photon virtualities Q<0.01 GeV. Single differential cross sections are measured as a function of W, the incident photon-proton centre of mass energy, and t, the square of the four-momentum transferred at the proton vertex, in the range 175measured |t| dependence is harder than that predicted by the model and those observed in exclusive vector meson production.

  1. Spatial distribution measured by the modulation transfer function

    International Nuclear Information System (INIS)

    Rossi, P.; Brice, D.K.; Doyle, B.L.

    2003-01-01

    Spatial distributions in ion micro-beam and IBA experimental practice are regularly characterized through the parameters of FWHM and tail area percentage (TF, tail fraction). Linear and stationary transducer theory allows these distributions to be described in the Fourier-dual frequency space, and provides an indirect method to evaluate them through measurement of the modulation transfer function (MTF). We suggest direct measurement of MTF by employing bar pattern grids, similar to those used for calibration of radiological equipment. Assuming spatial distributions of the form exp(-(|αx|) η ), we are able to relate the MTF measurements to the more popular FWHM and TF. This new approach to determine spatial resolution can become a standard for use by the micro-beam community

  2. Nuclear data and measurements series: Ratio of the prompt-fission-neutron spectrum of plutonium 239 to that of uranium 235

    International Nuclear Information System (INIS)

    Sugimoto, M.; Smith, A.B.; Guenther, P.T.

    1986-09-01

    The prompt-fission-neutron spectrum resulting from 239 Pu fission induced by 0.55 MeV incident neutrons is measured from 1.0 to 10.0 MeV relative to that of 235 U fission induced by the same incident-energy neutrons. The measurements employ the time-of-flight technique. Energy-dependent ratios of the two spectra are deduced from the measured values over the energy range 1.0 to 10.0 MeV. The experimentally-derived ratio results are compared with those calculated from ENDF/B-V, revision-2, and with results of recent microscopic measurements. Using the ENDF/B-V 235 U Watt parameters for the 235 U spectrum, the experimental measurements imply a ratio of average fission-spectrum energies of 239 Pu/ 235 U = 1.045 +- 0.003, compared to the value 1.046 calculated from ENDF/B-V, revision 2. 12 refs., 2 figs., 2 tabs

  3. Design and realization of temperature measurement system based on optical fiber temperature sensor for wireless power transfer

    Science.gov (United States)

    Chen, Xi; Zeng, Shuang; Liu, Xiulan; Jin, Yuan; Li, Xianglong; Wang, Xiaochen

    2018-02-01

    The electric vehicles (EV) have become accepted by increasing numbers of people for the environmental-friendly advantages. A novel way to charge the electric vehicles is through wireless power transfer (WPT). The wireless power transfer is a high power transfer system. The high currents flowing through the transmitter and receiver coils increasing temperature affects the safety of person and charging equipment. As a result, temperature measurement for wireless power transfer is needed. In this paper, a temperature measurement system based on optical fiber temperature sensors for electric vehicle wireless power transfer is proposed. Initially, the thermal characteristics of the wireless power transfer system are studied and the advantages of optical fiber sensors are analyzed. Then the temperature measurement system based on optical fiber temperature sensor is designed. The system consists of optical subsystem, data acquisition subsystem and data processing subsystem. Finally, the system is tested and the experiment result shows that the system can realize 1°C precision and can acquire real-time temperature distribution of the coils, which can meet the requirement of the temperature measuring for wireless power transfer.

  4. Wireless transfer of measured data. Continuous measurement of natural gas consumption in a liberalized market

    International Nuclear Information System (INIS)

    De Buisonje, B.

    2000-01-01

    In a deregulated market it is very important to be able to measure gas consumption per hour, or even every 5 minutes, on site and reliably transfer the data measured to the trader. It is common practice in the gas industry to make forecasts for each customer taking off more than 10 million m 3 . This requires the preparation of load profiles based on gas consumption during five minutes. For both the consumer and the trader it is important to be informed (semi-)continuously of the actual gas consumption, which can then be directly compared with the expected load profile, after which adjustments can be made. One of the gas distribution companies in the Netherlands, Essent, transfers wireless data in the case of remote metering. Essent uses Ferranti Computer Systems and the Mobitex network of RAM Mobile Data. Consumers also have access to the data measured through the Internet. They can use the actual load profile for billing purposes. Moreover, they can immediately adjust their energy consumption to stick to the offtake forecast as long as possible and thus save costs

  5. Are Autistic Traits Measured Equivalently in Individuals With and Without An Autism Spectrum Disorder? An Invariance Analysis of the Autism Spectrum Quotient Short Form

    OpenAIRE

    Murray, Aja Louise; Booth, Tom; McKenzie, Karen; Kuenssberg, Renate; O’Donnell, Michael

    2014-01-01

    It is common to administer measures of autistic traits to those without autism spectrum disorders (ASDs) with, for example, the aim of understanding autistic personality characteristics in non-autistic individuals. Little research has examined the extent to which measures of autistic traits actually measure the same traits in the same way across those with and without an ASD. We addressed this question using a multi-group confirmatory factor invariance analysis of the Autism Quotient Short Fo...

  6. Measurement of the transfer function of the main SPS Quadrupoles

    CERN Document Server

    Dinius, A; Semanaz, P; CERN. Geneva. SPS and LEP Division

    1998-01-01

    During two short MD's we have measured the transfer function (amplitude and phase) of the main quadrupole string QD. By the word string we mean the global effect of power supplies, magnets and the eddy current effects of the vacuum chamber. This paper presents the measurement procedure and the results, which are needed for the design of a real-time feedback system for the betatron tunes ( Qloop).

  7. Measurement of the Cosmic Ray primary spectrum with ARGO-YBJ experiment

    International Nuclear Information System (INIS)

    Panico, B; Iuppa, R; Di Sciascio, G

    2013-01-01

    The study of cosmic ray physic of 10 12 – 10 15 primary cosmic energy is one of the main goals of ARGO-YBJ experiment. The detector, located at the Yangbajing Cosmic Ray Laboratory (Tibet, 4300 m a.s.l., 606 g/cm 2 ), is an EAS array consisting of a continuous carpet of RPCs. The low energy threshold of the detector allows to study an energy region characterized by the transition from the direct to the indirect measurements. In this talk we will report on the measurement of the cosmic ray energy spectrum at different zenith angles. The phenomenology of horizontal air shower (θ > 70°) will be described and discussed.

  8. Systematic review of tools to measure outcomes for young children with autism spectrum disorder

    NARCIS (Netherlands)

    McConachie, H.; Parr, J.R.; Glod, M.; Hanratty, J.; Livingstone, N.; Oono, I.P.; Robalino, S.; Baird, G.; Beresford, B.; Charman, T.; Garland, D.; Green, J.; Gringras, P.; Jones, G.; Law, J.; Le Couteur, A.S.; Macdonald, G.; McColl, E.M.; Morris, C.; Rodgers, J.; Simonoff, E.; Terwee, C.B.; Williams, K.

    2015-01-01

    Background: The needs of children with autism spectrum disorder (ASD) are complex and this is reflected in the number and diversity of outcomes assessed and measurement tools used to collect evidence about children�s progress. Relevant outcomes include improvement in core ASD impairments, such as

  9. Measurement of dissolved hydrogen and hydrogen gas transfer in a hydrogen-producing reactor

    Energy Technology Data Exchange (ETDEWEB)

    Shizas, I.; Bagley, D.M. [Toronto Univ., ON (Canada). Dept. of Civil Engineering

    2004-07-01

    This paper presents a simple method to measure dissolved hydrogen concentrations in the laboratory using standard equipment and a series of hydrogen gas transfer tests. The method was validated by measuring hydrogen gas transfer parameters for an anaerobic reactor system that was purged with 10 per cent carbon dioxide and 90 per cent nitrogen using a coarse bubble diffuser stone. Liquid samples from the reactor were injected into vials and hydrogen was allowed to partition between the liquid and gaseous phases. The concentration of dissolved hydrogen was determined by comparing the headspace injections onto a gas chromatograph and a standard curve. The detection limit was 1.0 x 10{sup -5} mol/L of dissolved hydrogen. The gas transfer rate for hydrogen in basal medium and anaerobic digester sludge was used to validate the method. Results were compared with gas transfer models. In addition to monitoring dissolved hydrogen in reactor systems, this method can help improve hydrogen production potential. 1 ref., 4 figs.

  10. Measurement of the spectrum of electric-field fluctuations in a plasma by laser-fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Hildebrandt, J.; Kunze, H.

    1980-01-01

    Laser-fluorescence spectroscopy has been applied to measure the spectrum of electric wave fields with high temporal resolution in a pulsed hollow-cathode discharge. A low-frequency and a high-frequency component can be identified

  11. Online wave estimation using vessel motion measurements

    DEFF Research Database (Denmark)

    H. Brodtkorb, Astrid; Nielsen, Ulrik D.; J. Sørensen, Asgeir

    2018-01-01

    parameters and motion transfer functions are required as input. Apart from this the method is signal-based, with no assumptions on the wave spectrum shape, and as a result it is computationally efficient. The algorithm is implemented in a dynamic positioning (DP)control system, and tested through simulations......In this paper, a computationally efficient online sea state estimation algorithm isproposed for estimation of the on site sea state. The algorithm finds the wave spectrum estimate from motion measurements in heave, roll and pitch by iteratively solving a set of linear equations. The main vessel...

  12. The energy spectrum of cosmic-ray electrons measured with H.E.S.S

    International Nuclear Information System (INIS)

    Egberts, Kathrin

    2009-01-01

    The spectrum of cosmic-ray electrons has so far been measured using balloon and satellite-based instruments. At TeV energies, however, the sensitivity of such instruments is very limited due to the low flux of electrons at very high energies and small detection areas of balloon/satellite based experiments. The very large collection area of ground-based imaging atmospheric Cherenkov telescopes gives them a substantial advantage over balloon/ satellite based instruments when detecting very-high-energy electrons (> 300 GeV). By analysing data taken by the High Energy Stereoscopic System (H.E.S.S.), this work extends the known electron spectrum up to 4 TeV - a range that is not accessible to direct measurements. However, in contrast to direct measurements, imaging atmospheric Cherenkov telescopes such as H.E.S.S. detect air showers that cosmic-ray electrons initiate in the atmosphere rather than the primary particle. Thus, the main challenge is to differentiate between air showers initiated by electrons and those initiated by the hadronic background. A new analysis technique was developed that determines the background with the support of the machine-learning algorithm Random Forest. It is shown that this analysis technique can also be applied in other areas such as the analysis of diffuse γ rays from the Galactic plane. (orig.)

  13. The energy spectrum of cosmic-ray electrons measured with H.E.S.S.

    Energy Technology Data Exchange (ETDEWEB)

    Egberts, Kathrin

    2009-03-30

    The spectrum of cosmic-ray electrons has so far been measured using balloon and satellite-based instruments. At TeV energies, however, the sensitivity of such instruments is very limited due to the low flux of electrons at very high energies and small detection areas of balloon/satellite based experiments. The very large collection area of ground-based imaging atmospheric Cherenkov telescopes gives them a substantial advantage over balloon/ satellite based instruments when detecting very-high-energy electrons (> 300 GeV). By analysing data taken by the High Energy Stereoscopic System (H.E.S.S.), this work extends the known electron spectrum up to 4 TeV - a range that is not accessible to direct measurements. However, in contrast to direct measurements, imaging atmospheric Cherenkov telescopes such as H.E.S.S. detect air showers that cosmic-ray electrons initiate in the atmosphere rather than the primary particle. Thus, the main challenge is to differentiate between air showers initiated by electrons and those initiated by the hadronic background. A new analysis technique was developed that determines the background with the support of the machine-learning algorithm Random Forest. It is shown that this analysis technique can also be applied in other areas such as the analysis of diffuse {gamma} rays from the Galactic plane. (orig.)

  14. CFCI3 (CFC-11): UV Absorption Spectrum Temperature Dependence Measurements and the Impact on Atmospheric Lifetime and Uncertainty

    Science.gov (United States)

    Mcgillen, Max R.; Fleming, Eric L.; Jackman, Charles H.; Burkholder, James B.

    2014-01-01

    CFCl3 (CFC-11) is both an atmospheric ozone-depleting and potent greenhouse gas that is removed primarily via stratospheric UV photolysis. Uncertainty in the temperature dependence of its UV absorption spectrum is a significant contributing factor to the overall uncertainty in its global lifetime and, thus, model calculations of stratospheric ozone recovery and climate change. In this work, the CFC-11 UV absorption spectrum was measured over a range of wavelength (184.95 - 230 nm) and temperature (216 - 296 K). We report a spectrum temperature dependence that is less than currently recommended for use in atmospheric models. The impact on its atmospheric lifetime was quantified using a 2-D model and the spectrum parameterization developed in this work. The obtained global annually averaged lifetime was 58.1 +- 0.7 years (2 sigma uncertainty due solely to the spectrum uncertainty). The lifetime is slightly reduced and the uncertainty significantly reduced from that obtained using current spectrum recommendations

  15. Empirical wind retrieval model based on SAR spectrum measurements

    Science.gov (United States)

    Panfilova, Maria; Karaev, Vladimir; Balandina, Galina; Kanevsky, Mikhail; Portabella, Marcos; Stoffelen, Ad

    The present paper considers polarimetric SAR wind vector applications. Remote-sensing measurements of the near-surface wind over the ocean are of great importance for the understanding of atmosphere-ocean interaction. In recent years investigations for wind vector retrieval using Synthetic Aperture Radar (SAR) data have been performed. In contrast with scatterometers, a SAR has a finer spatial resolution that makes it a more suitable microwave instrument to explore wind conditions in the marginal ice zones, coastal regions and lakes. The wind speed retrieval procedure from scatterometer data matches the measured radar backscattering signal with the geophysical model function (GMF). The GMF determines the radar cross section dependence on the wind speed and direction with respect to the azimuthal angle of the radar beam. Scatterometers provide information on wind speed and direction simultaneously due to the fact that each wind vector cell (WVC) is observed at several azimuth angles. However, SAR is not designed to be used as a high resolution scatterometer. In this case, each WVC is observed at only one single azimuth angle. That is why for wind vector determination additional information such as wind streak orientation over the sea surface is required. It is shown that the wind vector can be obtained using polarimetric SAR without additional information. The main idea is to analyze the spectrum of a homogeneous SAR image area instead of the backscattering normalized radar cross section. Preliminary numerical simulations revealed that SAR image spectral maxima positions depend on the wind vector. Thus the following method for wind speed retrieval is proposed. In the first stage of the algorithm, the SAR spectrum maxima are determined. This procedure is carried out to estimate the wind speed and direction with ambiguities separated by 180 degrees due to the SAR spectrum symmetry. The second stage of the algorithm allows us to select the correct wind direction

  16. Measurement of Diffractive Scattering of Photons with Large Momentum Transfer at HERA

    CERN Document Server

    Aaron, F.D.; Andreev, V.; Antunovic, B.; Aplin, S.; Asmone, A.; Astvatsatourov, A.; Bacchetta, A.; Backovic, S.; Baghdasaryan, A.; Baranov, P.; Barrelet, E.; Bartel, W.; Beckingham, M.; Begzsuren, K.; Behnke, O.; Belousov, A.; Berger, N.; Bizot, J.C.; Boenig, M.-O.; Boudry, V.; Bozovic-Jelisavcic, I.; Bracinik, J.; Brandt, G.; Brinkmann, M.; Brisson, V.; Bruncko, D.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A.J.; Cantun Avila, K.B.; Cassol-Brunner, F.; Cerny, K.; Cerny, V.; Chekelian, V.; Cholewa, A.; Contreras, J.G.; Coughlan, J.A.; Cozzika, G.; Cvach, J.; Dainton, J.B.; Daum, K.; Deak, M.; de Boer, Y.; Delcourt, B.; Del Degan, M.; Delvax, J.; De Roeck, A.; De Wolf, E.A.; Diaconu, C.; Dodonov, V.; Dossanov, A.; Dubak, A.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eliseev, A.; Elsen, E.; Essenov, S.; Falkiewicz, A.; Faulkner, P.J.W.; Favart, L.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Finke, L.; Fleischer, M.; Fomenko, A.; Gabathuler, E.; Gayler, J.; Ghazaryan, Samvel; Glazov, A.; Glushkov, I.; Goerlich, L.; Goettlich, M.; Gogitidze, N.; Gouzevitch, M.; Grab, C.; Greenshaw, T.; Grell, B.R.; Grindhammer, G.; Habib, S.; Haidt, D.; Hansson, M.; Helebrant, C.; Henderson, R.C.W.; Henschel, H.; Herrera, G.; Hildebrandt, M.; Hiller, K.H.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Hreus, T.; Jacquet, M.; Janssen, M.E.; Janssen, X.; Jemanov, V.; Jonsson, L.; Johnson, D.P.; Jung, Andreas Werner; Jung, H.; Kapichine, M.; Katzy, J.; Kenyon, I.R.; Kiesling, C.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knutsson, A.; Kogler, R.; Korbel, V.; Kostka, P.; Kraemer, M.; Krastev, K.; Kretzschmar, J.; Kropivnitskaya, A.; Kruger, K.; Kutak, K.; Landon, M.P.J.; Lange, W.; Lastovicka-Medin, G.; Laycock, P.; Lebedev, A.; Leibenguth, G.; Lendermann, V.; Levonian, S.; Li, G.; Lipka, K.; Liptaj, A.; List, B.; List, J.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lucaci-Timoce, A.-I.; Lytkin, L.; Makankine, A.; Malinovski, E.; Marage, P.; Marti, Ll.; Martyn, H.-U.; Maxfield, S.J.; Mehta, A.; Meier, K.; Meyer, A.B.; Meyer, H.; Meyer, H.; Meyer, J.; Michels, V.; Mikocki, S.; Milcewicz-Mika, I.; Moreau, F.; Morozov, A.; Morris, J.V.; Mozer, Matthias Ulrich; Mudrinic, M.; Muller, K.; Murin, P.; Nankov, K.; Naroska, B.; Naumann, Th.; Newman, Paul R.; Niebuhr, C.; Nikiforov, A.; Nowak, G.; Nowak, K.; Nozicka, M.; Olivier, B.; Olsson, J.E.; Osman, S.; Ozerov, D.; Palichik, V.; Panagoulias, I.; Pandurovic, M.; Papadopoulou, Th.; Pascaud, C.; Patel, G.D.; Pejchal, O.; Peng, H.; Perez, E.; Petrukhin, A.; Picuric, I.; Piec, S.; Pitzl, D.; Placakyte, R.; Polifka, R.; Povh, B.; Preda, T.; Radescu, V.; Rahmat, A.J.; Raicevic, N.; Raspiareza, A.; Ravdandorj, T.; Reimer, P.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rotaru, M.; Ruiz Tabasco, J.E.; Rurikova, Z.; Rusakov, S.; Salek, D.; Salvaire, F.; Sankey, D.P.C.; Sauter, M.; Sauvan, E.; Schmidt, S.; Schmitt, S.; Schmitz, C.; Schoeffel, L.; Schoning, A.; Schultz-Coulon, H.-C.; Sefkow, F.; Shaw-West, R.N.; Sheviakov, I.; Shtarkov, L.N.; Shushkevich, S.; Sloan, T.; Smiljanic, Ivan; Smirnov, P.; Soloviev, Y.; Sopicki, P.; South, D.; Spaskov, V.; Specka, Arnd E.; Staykova, Z.; Steder, M.; Stella, B.; Straumann, U.; Sunar, D.; Sykora, T.; Tchoulakov, V.; Thompson, G.; Thompson, P.D.; Toll, T.; Tomasz, F.; Tran, T.H.; Traynor, D.; Trinh, T.N.; Truol, P.; Tsakov, I.; Tseepeldorj, B.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Urban, K.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Vargas Trevino, A.; Vazdik, Y.; Vinokurova, S.; Volchinski, V.; Wegener, D.; Wessels, M.; Wissing, Ch.; Wunsch, E.; Yeganov, V.; Zacek, J.; Zalesak, J.; Zhang, Z.; Zhelezov, A.; Zhokin, A.; Zhu, Y.C.; Zimmermann, T.; Zohrabyan, H.; Zomer, F.

    2009-01-01

    The first measurement of diffractive scattering of quasi-real photons with large momentum transfer gamma p -> gamma Y, where Y is the proton dissociative system, is made using the H1 detector at HERA. The measurement is performed for initial photon virtualities Q^2 < 0.01 GeV^2. Cross sections are measured as a function of W, the incident photon-proton entre of mass energy, and t, the square of the four-momentum transferred at the proton vertex, in the range 175 < W < 247 GeV and 4<|t|<36 GeV^2. The W dependence is well described by a model based on perturbative QCD using a leading logarithmic approximation of the BFKL evolution. The measured |t| dependence is harder than that predicted by the model and those observed in exclusive vector meson production.

  17. Emission spectrum of a harmonically trapped Λ-type three-level atom

    International Nuclear Information System (INIS)

    Guo Hong; Tang Pei

    2013-01-01

    We theoretically investigate the emission spectrum for a Λ-type three-level atom trapped in the node of a standing wave. We show that the atomic center-of-mass motion not only directly affects the peak number, peak position, and peak height in the atomic emission spectrum, but also influences the effects of the cavity field and the atomic initial state on atomic emission spectrum. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  18. Measurement and Quantum State Transfer in Superconducting Qubits

    Science.gov (United States)

    Mlinar, Eric

    The potential of superconducting qubits as the medium for a scalable quantum computer has motivated the pursuit of improved interactions within this system. Two challenges for the field of superconducting qubits are measurement fidelity, to accurately determine the state of the qubit, and the efficient transfer of quantum states. In measurement, the current state-of-the-art method employs dispersive readout, by coupling the qubit to a cavity and reading the resulting shift in cavity frequency to infer the qubit's state; however, this is vulnerable to Purcell relaxation, as well as being modeled off a simplified two-level abstraction of the qubit. In state transfer, the existing proposal for moving quantum states is mostly untested against non-idealities that will likely be present in an experiment. In this dissertation, we examine three problems within these two areas. We first describe a new scheme for fast and high-fidelity dispersive measurement specifically designed to circumvent the Purcell Effect. To do this, the qubit-resonator interaction is turned on only when the resonator is decoupled from the environment; then, after the resonator state has shifted enough to infer the qubit state, the qubit-resonator interaction is turned off before the resonator and environment are recoupled. We also show that the effectiveness of this "Catch-Disperse-Release'' procedure partly originates from quadrature squeezing of the resonator state induced by the Jaynes-Cummings nonlinearity. The Catch-Disperse-Release measurement scheme treats the qubit as a two-level system, which is a common simplification used in theoretical works. However, the most promising physical candidate for a superconducting qubit, the transmon, is a multi-level system. In the second work, we examine the effects of including the higher energy levels of the transmon. Specifically, we expand the eigenstate picture developed in the first work to encompass multiple qubit levels, and examine the resulting

  19. Measurement of the heat transfer coefficient in the dimpled channel: effects of dimple arrangement and channel height

    International Nuclear Information System (INIS)

    Shin, So Min; Lee, Ki Seon; Park, Seoung Duck; Kwak, Jae Su

    2009-01-01

    Heat transfer coefficients were measured in a channel with one side dimpled surface. The sphere type dimples were fabricated, and the diameter (D) and the depth of dimple was 16 mm and 4 mm, respectively. Two channel heights of about 0.6D and 1.2D, two dimple configurations were tested. The Reynolds number based on the channel hydraulic diameter was varied from 30000 to 50000. The improved hue detection based transient liquid crystal technique was used in the heat transfer measurement. Heat transfer measurement results showed that high heat transfer was induced downstream of the dimples due to flow reattachment. Due to the flow recirculation on the upstream side in the dimple, the heat transfer coefficient was very low. As the Reynolds increased, the overall heat transfer coefficients also increased. With the same dimple arrangement, the heat transfer coefficients and the thermal performance factors were higher for the lower channel height. As the distance between the dimples became smaller, the overall heat transfer coefficient and the thermal performance factors increased

  20. Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the design and use of a thin metallic calorimeter for measuring heat transfer rate (also called heat flux). Thermocouples are attached to the unexposed surface of the calorimeter. A one-dimensional heat flow analysis is used for calculating the heat transfer rate from the temperature measurements. Applications include aerodynamic heating, laser and radiation power measurements, and fire safety testing. 1.2 Advantages 1.2.1 Simplicity of ConstructionThe calorimeter may be constructed from a number of materials. The size and shape can often be made to match the actual application. Thermocouples may be attached to the metal by spot, electron beam, or laser welding. 1.2.2 Heat transfer rate distributions may be obtained if metals with low thermal conductivity, such as some stainless steels, are used. 1.2.3 The calorimeters can be fabricated with smooth surfaces, without insulators or plugs and the attendant temperature discontinuities, to provide more realistic flow conditions for ...

  1. Gamma spectrum measurement in a swimming-pool-type reactor

    International Nuclear Information System (INIS)

    Pla, E.

    1969-01-01

    After recalling the various modes of interaction of gamma rays with matter, the authors describe the design of a spectrometer for gamma energies of between 0.3 and 10 MeV. This spectrometer makes use of the Compton and pair-production effects without eliminating them. The collimator, the crystals and the electronics have been studied in detail and are described in their final form. The problem of calibrating the apparatus is then considered ; numerous graphs are given. The sensitivity of the spectrometer for different energies is determined mainly for the 'Compton effect' group. Finally, in the last part of the report, are given results of an experimental measurement of the gamma spectrum of a swimming-pool type reactor with new elements. (author) [fr

  2. Standard Test Method for Calculation of Stagnation Enthalpy from Heat Transfer Theory and Experimental Measurements of Stagnation-Point Heat Transfer and Pressure

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the calculation from heat transfer theory of the stagnation enthalpy from experimental measurements of the stagnation-point heat transfer and stagnation pressure. 1.2 Advantages 1.2.1 A value of stagnation enthalpy can be obtained at the location in the stream where the model is tested. This value gives a consistent set of data, along with heat transfer and stagnation pressure, for ablation computations. 1.2.2 This computation of stagnation enthalpy does not require the measurement of any arc heater parameters. 1.3 Limitations and ConsiderationsThere are many factors that may contribute to an error using this type of approach to calculate stagnation enthalpy, including: 1.3.1 TurbulenceThe turbulence generated by adding energy to the stream may cause deviation from the laminar equilibrium heat transfer theory. 1.3.2 Equilibrium, Nonequilibrium, or Frozen State of GasThe reaction rates and expansions may be such that the gas is far from thermodynamic equilibrium. 1.3.3 Noncat...

  3. Energy spectrum measurement of high power and high energy(6 and 9 MeV) pulsed x-ray source for industrial use

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Hiroyuki [Hitachi, Ltd. Power Systems Company, Ibaraki (Japan); Murata, Isao [Graduate School of Engineering, Osaka University, Osaka (Japan)

    2016-06-15

    Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

  4. Measurements of the neutron spectrum in transit to Mars on the Mars Science Laboratory.

    Science.gov (United States)

    Köhler, J; Ehresmann, B; Zeitlin, C; Wimmer-Schweingruber, R F; Hassler, D M; Reitz, G; Brinza, D E; Appel, J; Böttcher, S; Böhm, E; Burmeister, S; Guo, J; Lohf, H; Martin, C; Posner, A; Rafkin, S

    2015-04-01

    The Mars Science Laboratory spacecraft, containing the Curiosity rover, was launched to Mars on 26 November 2011. Although designed for measuring the radiation on the surface of Mars, the Radiation Assessment Detector (RAD) measured the radiation environment inside the spacecraft during most of the 253-day, 560-million-kilometer cruise to Mars. An important factor for determining the biological impact of the radiation environment inside the spacecraft is the specific contribution of neutrons with their high biological effectiveness. We apply an inversion method (based on a maximum-likelihood estimation) to calculate the neutron and gamma spectra from the RAD neutral particle measurements. The measured neutron spectrum (12-436 MeV) translates into a radiation dose rate of 3.8±1.2 μGy/day and a dose equivalent of 19±5 μSv/day. Extrapolating the measured spectrum (0.1-1000 MeV), we find that the total neutron-induced dose rate is 6±2 μGy/day and the dose equivalent rate is 30±10 μSv/day. For a 360 day round-trip from Earth to Mars with comparable shielding, this translates into a neutron induced dose equivalent of about 11±4 mSv. Copyright © 2015 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  5. Measurement of the very-forward energy spectrum in pp collisions at √(s) = 13 TeV with CMS

    Energy Technology Data Exchange (ETDEWEB)

    Baur, Sebastian; Akbiyik, Melike; Baus, Colin; Katkov, Igor; Ulrich, Ralf; Woehrmann, Hauke [Karlsruher Institut fuer Technologie (Germany)

    2016-07-01

    The energy spectrum dN/dE in pp collisions at a centre-of-mass energy of √(s)=13 TeV is measured with the CASTOR calorimeter of CMS at pseudorapidities -5.2>η>-6.6. The spectrum of the total energy, as well as the hadronic and electromagnetic energy, is presented and compared to models used to describe high-energy hadronic interactions. The performance also of model used to describe ultra-high energy cosmic ray air showers is tested, and the possible impact of the measurement on the air shower development is illustrated.

  6. Evaluation of Spectrum Usage for GSM band in Indoor and Outdoor Scenario for Dynamic Spectrum Access

    DEFF Research Database (Denmark)

    Patil, Kishor P.; Barge, Snehal; Skouby, Knud Erik

    2013-01-01

    , and transmit power. Several measurements have shown that the current spectrum is inefficiently utilized. The inefficient utilization problem can be solved with the help of Dynamic Spectrum Access. This paper describes the GSM band measurement conducted at different locations. In this paper, we report detailed...... measurement results of GSM band including statistical as well as spectral occupancy details obtained from measurement campaign conducted in Pune, India for indoor and outdoor scenarios. The results can be further used as an input for spectrum regulator for considering Cognitive Radio (CR) operation in GSM...

  7. Measurement of spin-transfer observables in pp to $\\Lambda \\Lambda$ at 1.637 GeV/c

    CERN Document Server

    Bassalleck, B; Bradtke, C; Bröders, R; Bunker, B; Dennert, H; Dutz, H; Eilerts, S W; Eyrich, W; Fields, D; Fischer, H; Franklin, G; Franz, J; Gehring, R; Geyer, R; Görtz, S; Harmsen, J; Hauffe, J; Heinsius, F H; Hertzog, D W; Johansson, T; Jones, T; Khaustov, P; Kilian, K; Kingsberry, P; Kriegler, E; Lowe, J; Meier, A; Metzger, A E; Meyer, C A; Meyer, Werner T; Moosburger, M; Oelert, W; Paschke, K D; Plückthun, M; Pomp, S; Quinn, B; Radtke, E; Reicherz, G; Röhrich, K; Sachs, K; Schmitt, H; Schoch, B; Sefzick, T; Stinzing, F; Stotzer, R W; Tayloe, R; Wirth, S

    2002-01-01

    Spin-transfer observables for pp to Lambda Lambda have been measured using a transversely polarized frozen-spin target and a beam momentum of 1.637 GeV/c. Current models of the reaction near threshold are in good agreement with existing measurements performed with unpolarized particles in the initial state but produce conflicting predictions for the spin-transfer observables D/sub nn/ and K/sub nn/ (the normal-to-normal depolarization and polarization transfer), which are measurable only with polarized target or beam. Measurements of D/sub nn/ and K/sub nn/ presented here are found to be in disagreement with predictions from these models. (21 refs).

  8. A Measurement of the Angular Power Spectrum of the Cosmic Microwave Background from L = 100 to 400

    Science.gov (United States)

    Miller, A. D.; Caldwell, R.; Devlin, M. J.; Dorwart, W. B.; Herbig, T.; Nolta, M. R.; Page, L. A.; Puchalla, J.; Torbet, E.; Tran, H. T.

    1999-10-01

    We report on a measurement of the angular spectrum of the cosmic microwave background (CMB) between l~100 and l~400 made at 144 GHz from Cerro Toco in the Chilean altiplano. When the new data are combined with previous data at 30 and 40 GHz taken with the same instrument observing the same section of sky, we find (1) a rise in the angular spectrum to a maximum with δTl~85 μK at l~200 and a fall at l>300, thereby localizing the peak near l~200, and (2) that the anisotropy at l~200 has the spectrum of the CMB.

  9. Debuncher Momentum Cooling Systems Signal to Noise Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Pasquinelli, Ralph J.; /Fermilab

    2001-12-18

    The Debuncher Momentum cooling systems were carefully measured for signal to noise. It was observed that cooling performance was not optimum. Closer inspection shows that the installed front-end bandpass filters are wider than the pickup response. (The original filters were specified to be wider so that none of the available bandwidth would be clipped.) The end result is excess noise is amplified and passed onto the kickers unimpeded, hence, reducing the achievable system gain. From this data, new filters should be designed to improve performance. New system bandwidths are specified on the data figures. Also included are the transfer function measurements that clearly show adjacent band response. In band 4 upper, the adjacent lobes are strong and out of phase. This is also degrading the system performance. The correlation between spectrum analyzer signal to noise and network analyzer system transfer functions is very strong. The table below has a calculation of expected improvement of front noise reduction by means of building new front-end bandpass filters. The calculation is based on a flat input noise spectrum and is a linear estimation of improvement. The listed 3dB bandwidths of the original filters are from measured data. The expected bandwidth is taken from the linear spectrum analyzer plots and is closer to a 10 dB bandwidth making the percentage improvement conservative. The signal to noise measurements are taken with circulating pbars in the Debuncher. One cooling system was measured at a time with all others off. Beam currents are below ten microamperes.

  10. Debuncher Momentum Cooling Systems Signal to Noise Measurements

    International Nuclear Information System (INIS)

    Pasquinelli, Ralph J.

    2001-01-01

    The Debuncher Momentum cooling systems were carefully measured for signal to noise. It was observed that cooling performance was not optimum. Closer inspection shows that the installed front-end bandpass filters are wider than the pickup response. (The original filters were specified to be wider so that none of the available bandwidth would be clipped.) The end result is excess noise is amplified and passed onto the kickers unimpeded, hence, reducing the achievable system gain. From this data, new filters should be designed to improve performance. New system bandwidths are specified on the data figures. Also included are the transfer function measurements that clearly show adjacent band response. In band 4 upper, the adjacent lobes are strong and out of phase. This is also degrading the system performance. The correlation between spectrum analyzer signal to noise and network analyzer system transfer functions is very strong. The table below has a calculation of expected improvement of front noise reduction by means of building new front-end bandpass filters. The calculation is based on a flat input noise spectrum and is a linear estimation of improvement. The listed 3dB bandwidths of the original filters are from measured data. The expected bandwidth is taken from the linear spectrum analyzer plots and is closer to a 10 dB bandwidth making the percentage improvement conservative. The signal to noise measurements are taken with circulating pbars in the Debuncher. One cooling system was measured at a time with all others off. Beam currents are below ten microamperes.

  11. Transfer Learning beyond Text Classification

    Science.gov (United States)

    Yang, Qiang

    Transfer learning is a new machine learning and data mining framework that allows the training and test data to come from different distributions or feature spaces. We can find many novel applications of machine learning and data mining where transfer learning is necessary. While much has been done in transfer learning in text classification and reinforcement learning, there has been a lack of documented success stories of novel applications of transfer learning in other areas. In this invited article, I will argue that transfer learning is in fact quite ubiquitous in many real world applications. In this article, I will illustrate this point through an overview of a broad spectrum of applications of transfer learning that range from collaborative filtering to sensor based location estimation and logical action model learning for AI planning. I will also discuss some potential future directions of transfer learning.

  12. Derivation and Cross-Validation of Cutoff Scores for Patients With Schizophrenia Spectrum Disorders on WAIS-IV Digit Span-Based Performance Validity Measures.

    Science.gov (United States)

    Glassmire, David M; Toofanian Ross, Parnian; Kinney, Dominique I; Nitch, Stephen R

    2016-06-01

    Two studies were conducted to identify and cross-validate cutoff scores on the Wechsler Adult Intelligence Scale-Fourth Edition Digit Span-based embedded performance validity (PV) measures for individuals with schizophrenia spectrum disorders. In Study 1, normative scores were identified on Digit Span-embedded PV measures among a sample of patients (n = 84) with schizophrenia spectrum diagnoses who had no known incentive to perform poorly and who put forth valid effort on external PV tests. Previously identified cutoff scores resulted in unacceptable false positive rates and lower cutoff scores were adopted to maintain specificity levels ≥90%. In Study 2, the revised cutoff scores were cross-validated within a sample of schizophrenia spectrum patients (n = 96) committed as incompetent to stand trial. Performance on Digit Span PV measures was significantly related to Full Scale IQ in both studies, indicating the need to consider the intellectual functioning of examinees with psychotic spectrum disorders when interpreting scores on Digit Span PV measures. © The Author(s) 2015.

  13. Frequency spectrum might act as communication code between retina and visual cortex I

    Directory of Open Access Journals (Sweden)

    Xu Yang

    2015-12-01

    Full Text Available AIM: To explore changes and possible communication relationship of local potential signals recorded simultaneously from retina and visual cortex I (V1. METHODS: Fourteen C57BL/6J mice were measured with pattern electroretinogram (PERG and pattern visually evoked potential (PVEP and fast Fourier transform has been used to analyze the frequency components of those signals. RESULTS: The amplitude of PERG and PVEP was measured at about 36.7 µV and 112.5 µV respectively and the dominant frequency of PERG and PVEP, however, stay unchanged and both signals do not have second, or otherwise, harmonic generation. CONCLUSION: The results suggested that retina encodes visual information in the way of frequency spectrum and then transfers it to primary visual cortex. The primary visual cortex accepts and deciphers the input visual information coded from retina. Frequency spectrum may act as communication code between retina and V1.

  14. Measurement of diffractive scattering of photons with large momentum transfer at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Aaron, F.D. [National Institute for Physics and Nuclear Engineering (NIPNE), Bucharest (Romania)]|[Bucharest Univ. (Romania). Faculty of Physics; Alexa, C. [National Institute for Physics and Nuclear Engineering (NIPNE), Bucharest (Romania); Andreev, V. [Lebedev Physical Institute, Moscow (RU)] (and others)

    2008-09-15

    The first measurement of diffractive scattering of quasi-real photons with large momentum transfer {gamma}p {yields} {gamma}Y, where Y is the proton dissociative system, is made using the H1 detector at HERA. The measurement is performed for initial photon virtualities Q{sup 2} < 0.01 GeV{sup 2}. Cross sections are measured as a function of W, the incident photonproton centre of mass energy, and t, the square of the four-momentum transferred at the proton vertex, in the range 175 < W < 247 GeV and 4 < vertical stroke t vertical stroke < 36 GeV{sup 2}. The W dependence is well described by a model based on perturbative QCD using a leading logarithmic approximation of the BFKL evolution. The measured vertical stroke t vertical stroke dependence is harder than that predicted by the model and those observed in exclusive vector meson production. (orig.)

  15. Measurement of multinucleon transfer cross-sections in Ni, Fe( C, x ...

    Indian Academy of Sciences (India)

    Measurement of multinucleon transfer cross-sections be treated as a stable particle in participation in nuclear reactions, thus the two-body kine- matics can be applied for the reaction (12C, 8Be) and the outgoing 8Be(g.s.) will have a unique kinetic energy at a given laboratory angle. To measure the cross-section for the.

  16. Quantum maps from transfer operators

    International Nuclear Information System (INIS)

    Bogomolny, E.B.; Carioli, M.

    1992-09-01

    The Selberg zeta function ζ S (s) yields an exact relationship between the periodic orbits of a fully chaotic Hamiltonian system (the geodesic flow on surfaces of constant negative curvature) and the corresponding quantum system (the spectrum of the Laplace-Beltrami operator on the same manifold). It was found that for certain manifolds, ζ S (s) can be exactly rewritten as the Fredholm-Grothendieck determinant det(1-T s ), where T s is a generalization of the Ruelle-Perron-Frobenius transfer operator. An alternative derivation of this result is given, yielding a method to find not only the spectrum but also the eigenfunctions of the Laplace-Beltrami operator in terms of eigenfunctions of T s . Various properties of the transfer operator are investigated both analytically and numerically for several systems. (author) 30 refs.; 16 figs.; 2 tabs

  17. SpecNet: Spectrum Sensing Sans Frontieres

    OpenAIRE

    Iyer, Anand Padmanabha; Chintalapudi, Krishna; Navda, Vishnu; Ramjee, Ramachandran; Padmanabhan, Venkata N; Murthy, Chandra R

    2011-01-01

    While the under-utilization of licensed spectrum based on measurement studies conducted in a few developed countries has spurred lots of interest in opportunistic spectrum access, there exists no infrastructure today for measuring real-time spectrum occupancy across vast geographical regions. In this paper, we present the design and implementation of SpecNet, a first-of-its-kind platform that allows spectrum analyzers around the world to be networked and efficiently used in a coordinated manner...

  18. Multiple Beta Spectrum Analysis Method Based on Spectrum Fitting

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Uk Jae; Jung, Yun Song; Kim, Hee Reyoung [UNIST, Ulsan (Korea, Republic of)

    2016-05-15

    When the sample of several mixed radioactive nuclides is measured, it is difficult to divide each nuclide due to the overlapping of spectrums. For this reason, simple mathematical analysis method for spectrum analysis of the mixed beta ray source has been studied. However, existing research was in need of more accurate spectral analysis method as it has a problem of accuracy. The study will describe the contents of the separation methods of the mixed beta ray source through the analysis of the beta spectrum slope based on the curve fitting to resolve the existing problem. The fitting methods including It was understood that sum of sine fitting method was the best one of such proposed methods as Fourier, polynomial, Gaussian and sum of sine to obtain equation for distribution of mixed beta spectrum. It was shown to be the most appropriate for the analysis of the spectrum with various ratios of mixed nuclides. It was thought that this method could be applied to rapid spectrum analysis of the mixed beta ray source.

  19. Heat transfer analysis in a calorimeter for concentrated solar radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Estrada, C.A.; Jaramillo, O.A.; Arancibia-Bulnes, C.A. [Universidad Nacional Autonoma de Mexico, Centro de Investigacion en Energia, Privada Xochicalco S/N, Col. Centro. Temixco, Morelos 62580 (Mexico); Acosta, R. [Universidad de Quintana Roo, Boulevard Bahia s/n Esq. I. Comonfort, Chetumal Quintana Roo 77019 (Mexico)

    2007-10-15

    A calorimeter was built for measuring the concentrated solar power produced by a point focus solar concentrator that was developed at CIE - UNAM. In order to obtain a thermal characterization of the calorimeter a theoretical and experimental heat transfer study is carried out. This study addresses the heat transfer in the circular flat plate of the calorimeter, which acts as receiver for the concentrating system. Temperatures are measured at different points of this plate and fit with a theoretical model that considers heat conduction with convective and radiative boundary conditions. In particular, it is possible to calculate the temperature distribution on the irradiated surface. This allows to examine the validity of the assumptions of cold water calorimetry, which was the technique applied to this system in previous works. (author)

  20. Measurement of multi-bunch transfer functions using time-domain data and Fourier analysis

    International Nuclear Information System (INIS)

    Hindi, H.; Sapozhnikov, L.; Fox, J.; Prabhakar, S.; Oxoby, G.; Linscott, I.; Drago, A.

    1993-12-01

    Multi-bunch transfer functions are principal ingredients in understanding both the behavior of high-current storage rings as well as control of their instabilities. The measurement of transfer functions on a bunch-by-bunch basis is particularly important in the design of active feedback systems. Traditional methods of network analysis that work well in the single bunch case become difficult to implement for many bunches. We have developed a method for obtaining empirical estimates of the multi-bunch longitudinal transfer functions from the time-domain measurements of the bunches' phase oscillations. This method involves recording the response of the bunch of interest to a white-noise excitation. The transfer function can then be computed as the ratio of the fast Fourier transforms (FFTs) of the response and excitation sequences, averaged over several excitations. The calculation is performed off-line on bunch-phase data and is well-suited to the multi-bunch case. A description of this method and an analysis of its performance is presented with results obtained using the longitudinal quick prototype feedback system developed at SLAC

  1. Heterodyne technique for measuring the amplitude and phase transfer functions of an optical modulator

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2002-01-01

    In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From the measure...... the measurements we derive the small-signal alpha-parameter and the time-dependent chirp for different operation conditions.......In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From...

  2. Indirect Measures of Learning Transfer between Real and Virtual Environments

    Science.gov (United States)

    Garrett, Michael; McMahon, Mark

    2013-01-01

    This paper reports on research undertaken to determine the effectiveness of a 3D simulation environment used to train mining personnel in emergency evacuation procedures, designated the Fires in Underground Mines Evacuation Simulator (FUMES). Owing to the operational constraints of the mining facility, methods for measuring learning transfer were…

  3. Investigating transfer gate potential barrier by feed-forward effect measurement

    NARCIS (Netherlands)

    Xu, Y.; Ge, X.; Theuwissen, A.J.P.

    2015-01-01

    In a 4T pixel, the transfer gate (TG) “OFF” surface potential is one of the important parameters, which determines the pinned photodiode (PPD) full well capacity. The feed-forward effect measurement is a powerful tool to characterize the relationship of the PPD injection potential and the

  4. Adult Autism Subthreshold Spectrum (AdAS Spectrum): Validation of a questionnaire investigating subthreshold autism spectrum.

    Science.gov (United States)

    Dell'Osso, L; Gesi, C; Massimetti, E; Cremone, I M; Barbuti, M; Maccariello, G; Moroni, I; Barlati, S; Castellini, G; Luciano, M; Bossini, L; Rocchetti, M; Signorelli, M; Aguglia, E; Fagiolini, A; Politi, P; Ricca, V; Vita, A; Carmassi, C; Maj, M

    2017-02-01

    Increasing literature has shown the usefulness of a dimensional approach to autism. The present study aimed to determine the psychometric properties of the Adult Autism Subthreshold Spectrum (AdAS Spectrum), a new questionnaire specifically tailored to assess subthreshold forms of autism spectrum disorder (ASD) in adulthood. 102 adults endorsing at least one DSM-5 symptom criterion for ASD (ASDc), 143 adults diagnosed with a feeding and eating disorder (FED), and 160 subjects with no mental disorders (CTL), were recruited from 7 Italian University Departments of Psychiatry and administered the following: SCID-5, Autism-Spectrum Quotient (AQ), Ritvo Autism and Asperger Diagnostic Scale 14-item version (RAADS-14), and AdAS Spectrum. The AdAS Spectrum demonstrated excellent internal consistency for the total score (Kuder-Richardson's coefficient=.964) as well as for five out of seven domains (all coefficients>.80) and sound test-retest reliability (ICC=.976). The total and domain AdAS Spectrum scores showed a moderate to strong (>.50) positive correlation with one another and with the AQ and RAADS-14 total scores. ASDc subjects reported significantly higher AdAS Spectrum total scores than both FED (pcriteria (FED 0 ) and those with one ASD symptom criterion (FED 1 ) , a gradient of severity in AdAS Spectrum scores from CTL subjects to ASD patients, across FED 0 , ASD 1 , FED 1 was shown. The AdAS Spectrum showed excellent internal consistency and test-retest reliability and strong convergent validity with alternative dimensional measures of ASD. The questionnaire performed differently among the three diagnostic groups and enlightened some significant effects of gender in the expression of autistic traits. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Energy transfer efficiency measurements in a theta-pinch

    International Nuclear Information System (INIS)

    Cavalcanti, G.H.; Luna, F.R.T.; Trigueiros, A.G.

    1993-01-01

    An increase in energy transfer efficiency of the capacitor bank to the plasma was obtained when the electrical system of a theta-pinch was changed so that the ratio of total inductance to coil inductance was switched of 1/6 to 1/2. A further increase about 20% was obtained for 16/1 ratio. The measurements were made through the current discharge decay, and the spectral analysis of the emitted light from theta-pinch shows a correspondent efficiency increase. (author)

  6. Deuteron form factor measurements at low momentum transfers

    Directory of Open Access Journals (Sweden)

    Schlimme B. S.

    2016-01-01

    Full Text Available A precise measurement of the elastic electron-deuteron scattering cross section at four-momentum transfers of 0.24 fm−1 ≤ Q ≤ 2.7 fm−1 has been performed at the Mainz Microtron. In this paper we describe the utilized experimental setup and the necessary analysis procedure to precisely determine the deuteron charge form factor from these data. Finally, the deuteron charge radius rd can be extracted from an extrapolation of that form factor to Q2 = 0.

  7. First measurement of the VESUVIO neutron spectrum in the 30-80 MeV energy range using a Proton Recoil Telescope technique

    Science.gov (United States)

    Cazzaniga, C.; Tardocchi, M.; Croci, G.; Frost, C.; Giacomelli, L.; Grosso, G.; Hjalmarsson, A.; Rebai, M.; Rhodes, N. J.; Schooneveld, E. M.; Gorini, G.

    2013-11-01

    Measurements of the fast neutron energy spectrum at the ISIS spallation source are reported. The measurements were performed with a Proton Recoil Telescope consisting of a thin plastic foil placed in the neutron beam and two scintillator detectors. Results in the neutron energy range 30 MeV < En < 80 MeV are in good agreement with Monte Carlo simulations of the neutron spectrum.

  8. The Relationship between Autism Symptoms and Arousal Level in Toddlers with Autism Spectrum Disorder, as Measured by Electrodermal Activity

    Science.gov (United States)

    Prince, Emily Barbara; Kim, Elizabeth S.; Wall, Carla Anne; Gisin, Eugenia; Goodwin, Matthew S.; Simmons, Elizabeth Schoen; Chawarska, Kaisa; Shic, Frederick

    2017-01-01

    Electrodermal activity was examined as a measure of physiological arousal within a naturalistic play context in 2-year-old toddlers (N = 27) with and without autism spectrum disorder. Toddlers with autism spectrum disorder were found to have greater increases in skin conductance level than their typical peers in response to administered play…

  9. Measurement of the atmospheric muon spectrum from 20 to 2000 GeV

    CERN Document Server

    Unger, Michael

    2003-01-01

    The atmospheric muon spectrum between 20 and 2000 GeV was measured with the L3 magnetic muon spectrometer for zenith angles ranging from 0 to 58 degrees. Due to the large data set and the good detector resolution, a precision of 2.6% at 100 GeV was achieved for the absolute normalization of the vertical muon flux. The momentum dependence of the ratio of positive to negative muons was obtained between 20 and 630 GeV.

  10. Research on spectrum broadening covering visible light of a fiber femtosecond optical frequency comb for absolute frequency measurement

    Science.gov (United States)

    Xing, Shuai; Wu, Tengfei; Li, Shuyi; Xia, Chuanqing; Han, Jibo; Zhang, Lei; Zhao, Chunbo

    2018-03-01

    As a bridge connecting microwave frequency and optical frequency, femtosecond laser has important significance in optical frequency measurement. Compared with the traditional Ti-sapphire femtosecond optical frequency comb, with the advantages of compact structure, strong anti-interference ability and low cost, the fiber femtosecond optical frequency comb has a wider application prospect. An experiment of spectrum broadening in a highly nonlinear photonic crystal fiber pumped by an Er-fiber mode-locked femtosecond laser is studied in this paper. Based on optical amplification and frequency doubling, the central wavelength of the output spectrum is 780nm and the average power is 232mW. With the femtosecond pulses coupled into two different photonic crystal fibers, the coverage of visible spectrum is up to 500nm-960nm. The spectral shape and width can be optimized by changing the polarization state for satisfying the requirments of different optical frequencies measurement.

  11. Sub-coulomb transfer method of a nucleon for measure orbital radii

    International Nuclear Information System (INIS)

    Aguilera R, E.F.; Murillo, G.; Ramirez, J.; Avila, O.

    1986-04-01

    The neutron transfer method is revised to measure neutron orbital radii and possible interest systems to apply it are determined. Its were carried out DWBA preliminary calculations for the system 209 Bi(d,t) 208 Bi. (Author)

  12. Measured wavenumber: frequency spectrum associated with acoustic and aerodynamic wall pressure fluctuations.

    Science.gov (United States)

    Arguillat, Blandine; Ricot, Denis; Bailly, Christophe; Robert, Gilles

    2010-10-01

    Direct measurements of the wavenumber-frequency spectrum of wall pressure fluctuations beneath a turbulent plane channel flow have been performed in an anechoic wind tunnel. A rotative array has been designed that allows the measurement of a complete map, 63×63 measuring points, of cross-power spectral densities over a large area. An original post-processing has been developed to separate the acoustic and the aerodynamic exciting loadings by transforming space-frequency data into wavenumber-frequency spectra. The acoustic part has also been estimated from a simple Corcos-like model including the contribution of a diffuse sound field. The measured acoustic contribution to the surface pressure fluctuations is 5% of the measured aerodynamic surface pressure fluctuations for a velocity and boundary layer thickness relevant for automotive interior noise applications. This shows that for aerodynamically induced car interior noise, both contributions to the surface pressure fluctuations on car windows have to be taken into account.

  13. Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line

    Science.gov (United States)

    Liu, Yingyi; Zhou, Lijuan; Liu, Yuanqing; Yuan, Haiwen; Ji, Liang

    2017-11-01

    Audible noise is closely related to corona current on a high voltage direct current (HVDC) transmission line. In this paper, we measured a large amount of audible noise and corona current waveforms simultaneously based on the largest outdoor HVDC corona cage all over the world. By analyzing the experimental data, the related statistical regularities between a corona current spectrum and an audible noise spectrum were obtained. Furthermore, the generation mechanism of audible noise was analyzed theoretically, and the related mathematical expression between the audible noise spectrum and the corona current spectrum, which is suitable for all of these measuring points in the space, has been established based on the electro-acoustic conversion theory. Finally, combined with the obtained mathematical relation, the internal reasons for these statistical regularities appearing in measured corona current and audible noise data were explained. The results of this paper not only present the statistical association regularities between the corona current spectrum and the audible noise spectrum on a HVDC transmission line, but also reveal the inherent reasons of these associated rules.

  14. Statistical measurement of power spectrum density of large aperture optical component

    International Nuclear Information System (INIS)

    Xu Jiancheng; Xu Qiao; Chai Liqun

    2010-01-01

    According to the requirement of ICF, a method based on statistical theory has been proposed to measure the power spectrum density (PSD) of large aperture optical components. The method breaks the large-aperture wavefront into small regions, and obtains the PSD of the large-aperture wavefront by weighted averaging of the PSDs of the regions, where the weight factor is each region's area. Simulation and experiment demonstrate the effectiveness of the proposed method. They also show that, the obtained PSDs of the large-aperture wavefront by statistical method and sub-aperture stitching method fit well, when the number of small regions is no less than 8 x 8. The statistical method is not sensitive to translation stage's errors and environment instabilities, thus it is appropriate for PSD measurement during the process of optical fabrication. (authors)

  15. Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wada, M., E-mail: mwada@mail.doshisha.ac.jp; Doi, K. [Graduate School of Science and Engineering, Doshisha University, Kyotanabe, Kyoto 610-0321 Japan (Japan); Kisaki, M.; Nakano, H.; Tsumori, K. [National Institute for Fusion Science, Toki, Gifu (Japan); Nishiura, M. [Graduate School of Frontier Sciences, The Universtiy of Tokyo, Chiba 277-8561 (Japan)

    2015-04-08

    Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum.

  16. Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

    International Nuclear Information System (INIS)

    Wada, M.; Doi, K.; Kisaki, M.; Nakano, H.; Tsumori, K.; Nishiura, M.

    2015-01-01

    Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum

  17. Recovery Temperature, Transition, and Heat Transfer Measurements at Mach 5

    Science.gov (United States)

    Brinich, Paul F.

    1961-01-01

    Schlieren, recovery temperature, and heat-transfer measurements were made on a hollow cylinder and a cone with axes alined parallel to the stream. Both the cone and cylinder were equipped with various bluntnesses, and the tests covered a Reynolds number range up to 20 x 10(exp 6) at a free-stream Mach number of 4.95 and wall to free-stream temperature ratios from 1.8 to 5.2 (adiabatic). A substantial transition delay due to bluntness was found for both the cylinder and the cone. For the present tests (Mach 4.95), transition was delayed by a factor of 3 on the cylinder and about 2 on the cone, these delays being somewhat larger than those observed in earlier tests at Mach 3.1. Heat-transfer tests on the cylinder showed only slight effects of wall temperature level on transition location; this is to be contrasted to the large transition delays observed on conical-type bodies at low surface temperatures at Mach 3.1. The schlieren and the peak-recovery-temperature methods of detecting transition were compared with the heat-transfer results. The comparison showed that the first two methods identified a transition point which occurred just beyond the end of the laminar run as seen in the heat-transfer data.

  18. Action Spectrum of Photoinhibition in the Diatom Phaeodactylum tricornutum.

    Science.gov (United States)

    Havurinne, Vesa; Tyystjärvi, Esa

    2017-12-01

    Light-dependent electron transfer is necessary for photosynthesis, but light also damages PSII. Light-induced damage to PSII is called photoinhibition, and the damaging reactions of photoinhibition are still under debate. Diatoms possess an exotic combination of light-harvesting pigments, Chls a/c and fucoxanthin, making them an interesting platform for studying the photoreceptors of photoinhibition. We first confirmed the direct proportionality of photoinhibition to the photon flux density of incident light in the diatom Phaeodactylum tricornutum. Phaeodactylum is known for its efficient non-photochemical quenching, and the effect of this photoprotective mechanism on photoinhibition was tested. Photoinhibition proceeded essentially at the same rate in blue-light-grown Phaeodactylum cells that are capable of non-photochemical quenching and in red-light-grown, non-photochemical quenching-deficient cells. To obtain more insight into how the pigment composition of diatoms affects photoinhibition, we measured the action spectrum of photoinhibition in Phaeodactylum. In visible light, the action spectrum resembled the absorption spectrum of Phaeodactylum, and UV radiation caused much more photoinhibition than visible light. Comparison of the action spectrum of photoinhibition with the absorption spectrum and the excitation spectrum of 77 K PSII fluorescence emission confirmed that photosynthetic pigments are involved in photoinhibition, but the photoinhibitory efficiency of red light is weak, suggesting that the role of light-harvesting pigments as light receptors of photoinhibition is secondary. Finally, we compared photoinhibition in Phaeodactylum with that in other photosynthetic organisms, and our data indicate that the PSII reaction centers of Phaeodactylum are not particularly well protected against the primary damage of photoinhibition. © The Author 2017. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights

  19. Design of Measurement and Control System of Composite Fast Transfer Switch Based on PLC

    Directory of Open Access Journals (Sweden)

    ZHANG Hong-yi

    2017-06-01

    Full Text Available The fast transfer switch gets more extensive application in the power supply system along with the raising of power supply requirement for continuity and reliability in the sensitivity loads such as in airport,military place,hospital and large scale industrial production line. Therefore it is important that how to make fast transfer switch run safely and reliably. The paper expatiated the structure and principle of a fast transfer switch based on mechanical and electronic compound technology,and,according to the basic requirement and the characteristic of the fast transfer switch,a PLC mastered measuring and controlling system has been designed to raise the operation reliability of the fast transfer switch.

  20. Interpretation of cosmic ray spectrum above the knee measured by the Tunka-133 array

    Energy Technology Data Exchange (ETDEWEB)

    Sveshnikova, Lyubov, E-mail: tfl10@mail.ru [Skobeltsyn Institute of Nuclear Physics MSU, Leninskie Gory GSP 1, Moscow 119992 (Russian Federation); Kuzmichev, Leonid; Korosteleva, Elena; Prosin, Vasiliy [Skobeltsyn Institute of Nuclear Physics MSU, Leninskie Gory GSP 1, Moscow 119992 (Russian Federation); Ptuskin, V.S. [Pushkov Institute of Terrestrial Magnetism, Ionosphere and Radio Wave Propogation (IZMIRAN), Russian Academy of Sciences, Troitsk, Moscow region 142092 (Russian Federation)

    2014-11-15

    A probable interpretation of the fine structure of all particle energy spectrum between the knee and the ankle (the sharp first knee at 3–4 PeV, the spectrum hardening at 20–30 PeV, the second knee at 200–300 PeV) as well as a (E) dependence measured recently by the Tunka-133 experiment, is presented. We show that these features are compatible with the combined model where cosmic rays around the knee are produced by the group of dedicated sources and the extragalactic light component appears in the energy region of 10{sup 16}–10{sup 17} eV and reaches about 50% of all particles around (2–3)×10{sup 17} eV.

  1. Combined fit of spectrum and composition data as measured by the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Aab, A. [Institute for Mathematics, Astrophysics and Particle Physics (IMAPP), Radboud Universiteit, Nijmegen (Netherlands); Abreu, P.; Andringa, S. [Laboratório de Instrumentação e Física Experimental de Partículas—LIP and Instituto Superior Técnico—IST, Universidade de Lisboa—UL (Portugal); Aglietta, M. [Osservatorio Astrofisico di Torino (INAF), Torino (Italy); Samarai, I. Al [Laboratoire de Physique Nucléaire et de Hautes Energies (LPNHE), Universités Paris 6 et Paris 7, CNRS-IN2P3 (France); Albuquerque, I.F.M. [Universidade de São Paulo, Inst. de Física, São Paulo (Brazil); Allekotte, I. [Centro Atómico Bariloche and Instituto Balseiro (CNEA-UNCuyo-CONICET) (Argentina); Almela, A.; Andrada, B. [Instituto de Tecnologías en Detección y Astropartículas (CNEA, CONICET, UNSAM), Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica (Argentina); Castillo, J. Alvarez [Universidad Nacional Autónoma de México, México (Mexico); Alvarez-Muñiz, J. [Universidad de Santiago de Compostela (Spain); Anastasi, G.A. [Gran Sasso Science Institute (INFN), L' Aquila (Italy); Anchordoqui, L., E-mail: auger_spokespersons@fnal.gov [Department of Physics and Astronomy, Lehman College, City University of New York (United States); and others

    2017-04-01

    We present a combined fit of a simple astrophysical model of UHECR sources to both the energy spectrum and mass composition data measured by the Pierre Auger Observatory. The fit has been performed for energies above 5 ⋅ 10{sup 18} eV, i.e. the region of the all-particle spectrum above the so-called 'ankle' feature. The astrophysical model we adopted consists of identical sources uniformly distributed in a comoving volume, where nuclei are accelerated through a rigidity-dependent mechanism. The fit results suggest sources characterized by relatively low maximum injection energies, hard spectra and heavy chemical composition. We also show that uncertainties about physical quantities relevant to UHECR propagation and shower development have a non-negligible impact on the fit results.

  2. On the importance of considering the incident spectrum when measuring the outdoor performance of amorphous silicon photovoltaic devices

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalg, R.; Betts, T.R.; Infield, D.G. [Loughborough University (United Kingdom). Department of Electronic and Electrical Engineering, Centre for Renewable Energy Systems Technology; Kearney, M.J. [University of Surrey, Guildford (United Kingdom). School of Electronics and Physical Sciences, Advanced Technology Institute

    2004-02-01

    Conventional measurement practice for the outdoor performance evaluation of solar cells does not make use of the complete spectrum, relying instead on the total irradiance as measured, say, with a pyranometer. In this paper it is shown that this can result in significant errors for solar cells having wide band gaps, in particular, for amorphous silicon solar cells. Two effects are investigated. The first relates to quantifying the typical errors associated with instantaneous measurements; what one might term the calibration of devices. The second relates to quantifying the impact of neglecting variations in the spectrum on the estimation of the annual energy production. It is observed that the fraction of the spectrum falling in the spectrally useful range for amorphous silicon can vary by as much as +10% to -15% with respect to standard test conditions at the test site used in this study, which translates directly into performance variations of similar magnitude. The relationship between changes due to spectral variations as opposed to variations in device temperature is also investigated. The results show that there is a strong case for investigating spectral effects more thoroughly, and explicitly including the measurement of the spectral distribution in all outdoor performance testing. (author)

  3. All-particle cosmic ray energy spectrum measured by the HAWC experiment from 10 to 500 TeV

    Science.gov (United States)

    Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Avila Rojas, D.; Ayala Solares, H. A.; Barber, A. S.; Becerril, A.; Belmont-Moreno, E.; BenZvi, S. Y.; Brisbois, C.; Caballero-Mora, K. S.; Capistrán, T.; Carramiñana, A.; Casanova, S.; Castillo, M.; Cotti, U.; Cotzomi, J.; Coutiño de León, S.; De León, C.; De la Fuente, E.; Diaz Hernandez, R.; Dichiara, S.; Dingus, B. L.; DuVernois, M. A.; Díaz-Vélez, J. C.; Ellsworth, R. W.; Enriquez-Rivera, O.; Fiorino, D. W.; Fleischhack, H.; Fraija, N.; García-González, J. A.; González Muñoz, A.; González, M. M.; Goodman, J. A.; Hampel-Arias, Z.; Harding, J. P.; Hernandez-Almada, A.; Hinton, J.; Hueyotl-Zahuantitla, F.; Hui, C. M.; Hüntemeyer, P.; Iriarte, A.; Jardin-Blicq, A.; Joshi, V.; Kaufmann, S.; Lara, A.; Lauer, R. J.; Lennarz, D.; León Vargas, H.; Linnemann, J. T.; Longinotti, A. L.; Luis Raya, G.; Luna-García, R.; López-Cámara, D.; López-Coto, R.; Malone, K.; Marinelli, S. S.; Martinez, O.; Martinez-Castellanos, I.; Martínez-Castro, J.; Martínez-Huerta, H.; Matthews, J. A.; Miranda-Romagnoli, P.; Moreno, E.; Mostafá, M.; Nellen, L.; Newbold, M.; Nisa, M. U.; Noriega-Papaqui, R.; Pelayo, R.; Pretz, J.; Pérez-Pérez, E. G.; Ren, Z.; Rho, C. D.; Rivière, C.; Rosa-González, D.; Rosenberg, M.; Ruiz-Velasco, E.; Salesa Greus, F.; Sandoval, A.; Schneider, M.; Schoorlemmer, H.; Sinnis, G.; Smith, A. J.; Springer, R. W.; Surajbali, P.; Taboada, I.; Tibolla, O.; Tollefson, K.; Torres, I.; Ukwatta, T. N.; Villaseñor, L.; Weisgarber, T.; Westerhoff, S.; Wood, J.; Yapici, T.; Zepeda, A.; Zhou, H.; HAWC Collaboration

    2017-12-01

    We report on the measurement of the all-particle cosmic ray energy spectrum with the High Altitude Water Cherenkov (HAWC) Observatory in the energy range 10 to 500 TeV. HAWC is a ground-based air-shower array deployed on the slopes of Volcan Sierra Negra in the state of Puebla, Mexico, and is sensitive to gamma rays and cosmic rays at TeV energies. The data used in this work were taken over 234 days between June 2016 and February 2017. The primary cosmic-ray energy is determined with a maximum likelihood approach using the particle density as a function of distance to the shower core. Introducing quality cuts to isolate events with shower cores landing on the array, the reconstructed energy distribution is unfolded iteratively. The measured all-particle spectrum is consistent with a broken power law with an index of -2.49 ±0.01 prior to a break at (45.7 ±0.1 ) TeV , followed by an index of -2.71 ±0.01 . The spectrum also represents a single measurement that spans the energy range between direct detection and ground-based experiments. As a verification of the detector response, the energy scale and angular resolution are validated by observation of the cosmic ray Moon shadow's dependence on energy.

  4. Measurement of electromagnetic fields generated by air traffic control radar systems with spectrum analysers.

    Science.gov (United States)

    Barellini, A; Bogi, L; Licitra, G; Silvi, A M; Zari, A

    2009-12-01

    Air traffic control (ATC) primary radars are 'classical' radars that use echoes of radiofrequency (RF) pulses from aircraft to determine their position. High-power RF pulses radiated from radar antennas may produce high electromagnetic field levels in the surrounding area. Measurement of electromagnetic fields produced by RF-pulsed radar by means of a swept-tuned spectrum analyser are investigated here. Measurements have been carried out both in the laboratory and in situ on signals generated by an ATC primary radar.

  5. Measurement of electromagnetic fields generated by air traffic control radar systems with spectrum analysers

    International Nuclear Information System (INIS)

    Barellini, A.; Bogi, L.; Licitra, G.; Silvi, A. M.; Zari, A.

    2009-01-01

    Air traffic control (ATC) primary radars are 'classical' radars that use echoes of radiofrequency (RF) pulses from aircraft to determine their position. High-power RF pulses radiated from radar antennas may produce high electromagnetic field levels in the surrounding area. Measurement of electromagnetic fields produced by RF-pulsed radar by means of a swept-tuned spectrum analyser are investigated here. Measurements have been carried out both in the laboratory and in situ on signals generated by an ATC primary radar. (authors)

  6. Inferring a Drive-Response Network from Time Series of Topological Measures in Complex Networks with Transfer Entropy

    Directory of Open Access Journals (Sweden)

    Xinbo Ai

    2014-11-01

    Full Text Available Topological measures are crucial to describe, classify and understand complex networks. Lots of measures are proposed to characterize specific features of specific networks, but the relationships among these measures remain unclear. Taking into account that pulling networks from different domains together for statistical analysis might provide incorrect conclusions, we conduct our investigation with data observed from the same network in the form of simultaneously measured time series. We synthesize a transfer entropy-based framework to quantify the relationships among topological measures, and then to provide a holistic scenario of these measures by inferring a drive-response network. Techniques from Symbolic Transfer Entropy, Effective Transfer Entropy, and Partial Transfer Entropy are synthesized to deal with challenges such as time series being non-stationary, finite sample effects and indirect effects. We resort to kernel density estimation to assess significance of the results based on surrogate data. The framework is applied to study 20 measures across 2779 records in the Technology Exchange Network, and the results are consistent with some existing knowledge. With the drive-response network, we evaluate the influence of each measure by calculating its strength, and cluster them into three classes, i.e., driving measures, responding measures and standalone measures, according to the network communities.

  7. The Atacama Cosmology Telescope: A Measurement of the Cosmic Microwave Background Power Spectrum at 148 AND 218 GHz from the 2008 Southern Survey

    Science.gov (United States)

    Das, Sudeep; Marriage, Tobias A.; Ade, Peter A. R.; Aguirre, Paula; Amiri, Mandana; Appel, John W.; Barrientos, L. Felipe; Battistelli, Elia A.; Bond, J. Richard; Brown, Ben; hide

    2010-01-01

    We present measurements of the cosmic microwave background (CMB) power spectrum made by the Atacama Cosmology Telescope at 148 GHz and 218 GHz, as well as the cross-frequency spectrum between the two channels. Our results dearly show the second through the seventh acoustic peaks in the CMB power spectrum. The measurements of these higher-order peaks provide an additional test of the ACDM cosmological model. At l > 3000, we detect power in excess of the primary anisotropy spectrum of the CMB. At lower multipoles 500 < l < 3000, we find evidence for gravitational lensing of the CMB in the power spectrum at the 2.8(sigma) level. We also detect a low level of Galactic dust in our maps, which demonstrates that we can recover known faint, diffuse signals.

  8. MEASUREMENTS OF THE MEAN DIFFUSE GALACTIC LIGHT SPECTRUM IN THE 0.95–1.65 μm BAND FROM CIBER

    Energy Technology Data Exchange (ETDEWEB)

    Arai, T.; Matsuura, S.; Sano, K.; Matsumoto, T.; Nakagawa, T.; Onishi, Y. [Department of Space Astronomy and Astrophysics, Institute of Space and Astronautical Science (ISAS), Japan Aerospace Exploration Agency (JAXA), Sagamihara, Kanagawa 252-5210 (Japan); Bock, J.; Lanz, A.; Korngut, P.; Zemcov, M. [Department of Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Cooray, A.; Smidt, J. [Center for Cosmology, University of California, Irvine, Irvine, CA 92697 (United States); Kim, M. G.; Lee, H. M. [Department of Physics and Astronomy, Seoul National University, Seoul 151-742 (Korea, Republic of); Lee, D. H. [Korea Astronomy and Space Science Institute (KASI), Daejeon 305-348 (Korea, Republic of); Shirahata, M. [National Institutes of Natural Science, National Astronomical Observatory of Japan (NAOJ), Tokyo 181-8588 (Japan); Tsumura, K. [Frontier Research Institute for Interdisciplinary Science, Tohoku University, Sendai 980-8578 (Japan)

    2015-06-10

    We report measurements of the diffuse galactic light (DGL) spectrum in the near-infrared, spanning the wavelength range 0.95–1.65 μm by the Cosmic Infrared Background ExpeRiment. Using the low-resolution spectrometer calibrated for absolute spectro-photometry, we acquired long-slit spectral images of the total diffuse sky brightness toward six high-latitude fields spread over four sounding rocket flights. To separate the DGL spectrum from the total sky brightness, we correlated the spectral images with a 100 μm intensity map, which traces the dust column density in optically thin regions. The measured DGL spectrum shows no resolved features and is consistent with other DGL measurements in the optical and at near-infrared wavelengths longer than 1.8 μm. Our result implies that the continuum is consistently reproduced by models of scattered starlight in the Rayleigh scattering regime with a few large grains.

  9. Technology transfer trends in Indian space programme

    Science.gov (United States)

    Sridhara Murthi, K. R.; Shoba, T. S.

    2010-10-01

    Indian space programme, whose objectives involve acceleration of economic and social development through applications of space technology, has been engaged in the development of state-of-the-art satellite systems, launch vehicles and equipment necessary for applications. Even during the early phase of evolution of this Programme, deliberate policies have been adopted by the national space agency, namely, Indian Space Research Organisation (ISRO), to promote spin-off benefit from the technologies developed for the use of space projects. Consistently adhering to this policy, ISRO has transferred over 280 technologies till date, spanning a wide spectrum of disciplines. This has resulted in a fruitful two-way cooperation between a number of SMEs and the ISRO. In order to make the technology transfer process effective, ISRO has adopted a variety of functional and organizational policies that included awareness building measures, licensee selection methods, innovative contract systems, diverse transfer processes, post licencing services and feedback mechanisms. Besides analyzing these policies and their evolution, the paper discusses various models adopted for technology transfer and their impact on assessment. It also touches upon relevant issues relating to creating interface between public funded R&D and the private commercial enterprises. It suggests few models in which international cooperation could be pursued in this field.

  10. DERMAL AND MOUTHING TRANSFERS OF SURFACE RESIDUES MEASURED USING FLUORESCENCE IMAGING

    Science.gov (United States)

    To reduce the uncertainty associated with current estimates of children's exposure to pesticides by dermal contact and non-dietary ingestion, residue transfer data are required. Prior to conducting exhaustive studies, a screening study to develop and test methods for measuring...

  11. Heat Transfer Measurement and Modeling in Rigid High-Temperature Reusable Surface Insulation Tiles

    Science.gov (United States)

    Daryabeigi, Kamran; Knutson, Jeffrey R.; Cunnington, George R.

    2011-01-01

    Heat transfer in rigid reusable surface insulations was investigated. Steady-state thermal conductivity measurements in a vacuum were used to determine the combined contribution of radiation and solid conduction components of heat transfer. Thermal conductivity measurements at higher pressures were then used to estimate the effective insulation characteristic length for gas conduction modeling. The thermal conductivity of the insulation can then be estimated at any temperature and pressure in any gaseous media. The methodology was validated by comparing estimated thermal conductivities with published data on a rigid high-temperature silica reusable surface insulation tile. The methodology was also applied to the alumina enhanced thermal barrier tiles. Thermal contact resistance for thermal conductivity measurements on rigid tiles was also investigated. A technique was developed to effectively eliminate thermal contact resistance on the rigid tile s cold-side surface for the thermal conductivity measurements.

  12. Measurement of the energy spectrum of cosmic rays from the Pierre Auger Observatory

    International Nuclear Information System (INIS)

    Roth, M.

    2009-01-01

    The large sample of data collected by the Pierre Auger Observatory has led to a significant improvement over previous measurements on the energy spectrum of cosmic rays. We observe a suppression of the flux at the highest energy with a significance of more than 6 standard deviations. The spectral index γ of the flux, J∝E -γ , at energies between 4x10 18 eV and 4x10 19 eV is 2.69±0.02 (stat) ±0.06 (syst), steepening to 4.2±0.4 (stat) ±0.06 (syst) at higher energies, consistent with the prediction by Greisen and by Zatsepin and Kuz'min. Observations of cosmic rays by the fluorescence detector allowed the extension of the energy spectrum to lower energies, where the efficiency of the surface detector is less then 100% and a change in the spectral index is expected.

  13. Computational study of energy transfer in two-dimensional J-aggregates

    International Nuclear Information System (INIS)

    Gallos, Lazaros K.; Argyrakis, Panos; Lobanov, A.; Vitukhnovsky, A.

    2004-01-01

    We perform a computational analysis of the intra- and interband energy transfer in two-dimensional J-aggregates. Each aggregate is represented as a two-dimensional array (LB-film or self-assembled film) of two kinds of cyanine dyes. We consider the J-aggregate whose J-band is located at a shorter wavelength to be a donor and an aggregate or a small impurity with longer wavelength to be an acceptor. Light absorption in the blue wing of the donor aggregate gives rise to the population of its excitonic states. The depopulation of these states is possible by (a) radiative transfer to the ground state (b) intraband energy transfer, and (c) interband energy transfer to the acceptor. We study the dependence of energy transfer on properties such as the energy gap, the diagonal disorder, and the exciton-phonon interaction strength. Experimentally observable parameters, such as the position and form of luminescence spectrum, and results of the kinetic spectroscopy measurements strongly depend upon the density of states in excitonic bands, rates of energy exchange between states and oscillator strengths for luminescent transitions originating from these states

  14. Calculation of color difference and measurement of the spectrum of aerosol based on human visual system

    Science.gov (United States)

    Dai, Mengyan; Liu, Jianghai; Cui, Jianlin; Chen, Chunsheng; Jia, Peng

    2017-10-01

    In order to solve the problem of the quantitative test of spectrum and color of aerosol, the measurement method of spectrum of aerosol based on human visual system was proposed. The spectrum characteristics and color parameters of three different aerosols were tested, and the color differences were calculated according to the CIE1976-L*a*b* color difference formula. Three tested powders (No 1# No 2# and No 3# ) were dispersed in a plexglass box and turned into aerosol. The powder sample was released by an injector with different dosages in each experiment. The spectrum and color of aerosol were measured by the PRO 6500 Fiber Optic Spectrometer. The experimental results showed that the extinction performance of aerosol became stronger and stronger with the increase of concentration of aerosol. While the chromaticity value differences of aerosols in the experiment were so small, luminance was verified to be the main influence factor of human eye visual perception and contributed most in the three factors of the color difference calculation. The extinction effect of No 3# aerosol was the strongest of all and caused the biggest change of luminance and color difference which would arouse the strongest human visual perception. According to the sensation level of chromatic color by Chinese, recognition color difference would be produced when the dosage of No 1# powder was more than 0.10 gram, the dosage of No 2# powder was more than 0.15 gram, and the dosage of No 3# powder was more than 0.05 gram.

  15. Use of boron nitride for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Radulović, Vladimir, E-mail: vladimir.radulovic@ijs.si [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Trkov, Andrej [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); IAEA, Vienna International Centre, PO Box 100, A-1400 Vienna (Austria); Jaćimović, Radojko [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Gregoire, Gilles; Destouches, Christophe [CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St. Paul-Lez-Durance (France)

    2016-12-21

    A recent experimental irradiation and measurement campaign using containers made from boron nitride (BN) at the Jožef Stefan Institute (JSI) TRIGA Mark II reactor in Ljubljana, Slovenia, has shown the applicability of BN for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements. The first part of the paper focuses on the determination of the transmission function of a BN container through Monte Carlo calculations and experimental measurements. The second part presents the process of tayloring the sensitivity of integral activation measurements to specific needs and a selection of suitable radiative capture reactions for neutron spectrum characterization in the epithermal range. A BN container used in our experiments and its qualitative effect on the neutron spectrum in the irradiation position employed is displayed in the Graphical abstract. - Graphical abstract: Neutron spectra inside the JSI TRIGA Mark II PT irradiation position, obtained with a Monte Carlo calculation: blue: unperturbed, green inside a BN container, of wall thickness 4 mm, 13 mm in diameter and 14 mm in height.

  16. Use of boron nitride for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements

    International Nuclear Information System (INIS)

    Radulović, Vladimir; Trkov, Andrej; Jaćimović, Radojko; Gregoire, Gilles; Destouches, Christophe

    2016-01-01

    A recent experimental irradiation and measurement campaign using containers made from boron nitride (BN) at the Jožef Stefan Institute (JSI) TRIGA Mark II reactor in Ljubljana, Slovenia, has shown the applicability of BN for neutron spectrum characterization and cross-section validation in the epithermal range through integral activation measurements. The first part of the paper focuses on the determination of the transmission function of a BN container through Monte Carlo calculations and experimental measurements. The second part presents the process of tayloring the sensitivity of integral activation measurements to specific needs and a selection of suitable radiative capture reactions for neutron spectrum characterization in the epithermal range. A BN container used in our experiments and its qualitative effect on the neutron spectrum in the irradiation position employed is displayed in the Graphical abstract. - Graphical abstract: Neutron spectra inside the JSI TRIGA Mark II PT irradiation position, obtained with a Monte Carlo calculation: blue: unperturbed, green inside a BN container, of wall thickness 4 mm, 13 mm in diameter and 14 mm in height.

  17. Quantitative assessment of human exposure to extended spectrum and AmpC β-lactamases bearing E. coli in lettuce attributable to irrigation water and subsequent horizontal gene transfer.

    Science.gov (United States)

    Njage, P M K; Buys, E M

    2017-01-02

    The contribution of the fresh produce production environment to human exposure with bacteria bearing extended spectrum β-lactamases and AmpC β-lactamases (ESBL/AmpC) has not been reported. High prevalence of ESBLs/AmpC bearing E. coli as well as a high gene transfer efficiency of lettuce and irrigation water E. coli isolates was previously reported. This stochastic modeling was aimed at quantitatively assessing human exposure to ESBL/AmpC bearing E. coli through lettuce attributable to irrigation water and subsequent horizontal gene transfer. Modular process risk approach was used for the quantitative exposure assessment and models were constructed in Ms. Excel spreadsheet with farm to consumption chain accounted for by primary production, processing, retail and consumer storage. Probability distributions were utilised to take into account the variability of the exposure estimates. Exposure resulting from ESBL/AmpC positive E. coli and gene transfer was taken into account. Monte Carlo simulation was carried out using @Risk software followed by sensitivity and scenario analysis to assess most effective single or combinations of mitigation strategies for the ESBL/AmpC positive E. coli events from farm to fork. Three percent of South African lettuce consumers are exposed to lettuce contaminated with about 10 6.4 ±10 6.7 (95% CI: 10 5.1 -10 7 ) cfu of ESBL/AmpC positive E. coli per serving. The contribution of originally positive isolates and conjugative genetic transfer was 10 6 ±10 6.7 (95% CI: 10 5 -10 7 ) and 10 5.2 ±10 5.6 (95% CI: 10 3.9 -10 5.8 ) cfu per serving respectively. Proportion of ESBL/AmpC positive E. coli (Spearman's correlation coefficient (ρ)=0.85), conjugative gene transfer (ρ=0.05-0.14), washing in chlorine water (ρ=0.18), further rinsing (ρ=0.15), and prevalence of E. coli in irrigation water (ρ=0.16) had highest influence on consumer exposure. The most effective single methods in reducing consumer exposure were reduction in irrigation

  18. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF.

    Science.gov (United States)

    Casey, D T; Frenje, J A; Johnson, M Gatu; Séguin, F H; Li, C K; Petrasso, R D; Glebov, V Yu; Katz, J; Magoon, J; Meyerhofer, D D; Sangster, T C; Shoup, M; Ulreich, J; Ashabranner, R C; Bionta, R M; Carpenter, A C; Felker, B; Khater, H Y; LePape, S; MacKinnon, A; McKernan, M A; Moran, M; Rygg, J R; Yeoman, M F; Zacharias, R; Leeper, R J; Fletcher, K; Farrell, M; Jasion, D; Kilkenny, J; Paguio, R

    2013-04-01

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  19. The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

    International Nuclear Information System (INIS)

    Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Séguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Magoon, J.; Meyerhofer, D. D.; Sangster, T. C.; Shoup, M.; Ulreich, J.; Ashabranner, R. C.; Bionta, R. M.; Carpenter, A. C.; Felker, B.; Khater, H. Y.; LePape, S.; MacKinnon, A.

    2013-01-01

    The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facility and the National Ignition Facility (NIF) to measure the absolute neutron spectrum from 3 to 30 MeV at OMEGA and 3 to 36 MeV at the NIF. These measurements have been used to diagnose the performance of cryogenic target implosions to unprecedented accuracy. Interpretation of MRS data requires a detailed understanding of the MRS response and background. This paper describes ab initio characterization of the system involving Monte Carlo simulations of the MRS response in addition to the commission experiments for in situ calibration of the systems on OMEGA and the NIF.

  20. Measurement of the neutron spectrum of the Big Ten critical assembly by lithium-6 spectrometry

    International Nuclear Information System (INIS)

    De Leeuw-Gierts, G.; De Leeuw, S.; Hansen, G.E.; Helmick, H.H.

    1979-01-01

    The central neutron-flux spectrum of the Los Alamos Scientific Laboratory's critical assembly, Big Ten, was measured with a 6 Li spectrometer and techniques developed at the Centre d'Etude de L'Energie Nucleaire, Mol, as part of an experimental program to establish the characteristics of Big Ten

  1. Measurement of the neutron spectrum of the Big Ten critical assembly by lithium-6 spectrometry

    International Nuclear Information System (INIS)

    Leeuw-Gierts, G. de; Leeuw, S. de

    1980-01-01

    The central neutron-flux spectrum of the Los Alamos Scientific Laboratory's critical assembly, Big Ten, was measured with a 6 Li spectrometer and techniques developed at the Centre d'Etude de l'Energie Nucleaire, Mol, as part of an experimental program to establish the characteristics of Big Ten

  2. First measurement of the VESUVIO neutron spectrum in the 30–80 MeV energy range using a Proton Recoil Telescope technique

    International Nuclear Information System (INIS)

    Cazzaniga, C; Tardocchi, M; Croci, G; Grosso, G; Rebai, M; Gorini, G; Frost, C; Rhodes, N J; Schooneveld, E M; Giacomelli, L; Hjalmarsson, A

    2013-01-01

    Measurements of the fast neutron energy spectrum at the ISIS spallation source are reported. The measurements were performed with a Proton Recoil Telescope consisting of a thin plastic foil placed in the neutron beam and two scintillator detectors. Results in the neutron energy range 30 MeV n < 80 MeV are in good agreement with Monte Carlo simulations of the neutron spectrum

  3. Working Memory Training Does Not Improve Performance on Measures of Intelligence or Other Measures of "Far Transfer": Evidence From a Meta-Analytic Review.

    Science.gov (United States)

    Melby-Lervåg, Monica; Redick, Thomas S; Hulme, Charles

    2016-07-01

    It has been claimed that working memory training programs produce diverse beneficial effects. This article presents a meta-analysis of working memory training studies (with a pretest-posttest design and a control group) that have examined transfer to other measures (nonverbal ability, verbal ability, word decoding, reading comprehension, or arithmetic; 87 publications with 145 experimental comparisons). Immediately following training there were reliable improvements on measures of intermediate transfer (verbal and visuospatial working memory). For measures of far transfer (nonverbal ability, verbal ability, word decoding, reading comprehension, arithmetic) there was no convincing evidence of any reliable improvements when working memory training was compared with a treated control condition. Furthermore, mediation analyses indicated that across studies, the degree of improvement on working memory measures was not related to the magnitude of far-transfer effects found. Finally, analysis of publication bias shows that there is no evidential value from the studies of working memory training using treated controls. The authors conclude that working memory training programs appear to produce short-term, specific training effects that do not generalize to measures of "real-world" cognitive skills. These results seriously question the practical and theoretical importance of current computerized working memory programs as methods of training working memory skills. © The Author(s) 2016.

  4. An empirical line-by-line model for the infrared solar transmittance spectrum from 700 to 5000cm{sup -1}

    Energy Technology Data Exchange (ETDEWEB)

    Hase, F. [Institut fuer Meteorologie und Klimaforschung, Forschungszentrum Karlsruhe, Postfach 3640, D-76021 Karlsruhe (Germany)]. E-mail: frank.hase@imk.fzk.de; Demoulin, P. [Institut d' Astrophysique et de Geophysique, allee du VI aout, 17, batiment B5a, B-4000, Liege (Belgium); Sauval, A.J. [Observatoire Royal de Belgique, avenue circulaire, 3, B-1180, Bruxelles (Belgium); Toon, G.C. [Jet Propulsion Laboratory, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Bernath, P.F. [Department of Chemistry, University of Waterloo, Waterloo, Ont., Canada N2L3G1 (Canada); Goldman, A. [Department of Physics, University of Denver, Denver, CO 80208 (United States); Hannigan, J.W. [Atmospheric Chemistry Division, National Center for Atmospheric Research, P.O. Box 3000, Boulder, CO 80303 (United States); Rinsland, C.P. [NASA Langley Research Center, Hampton, VA 23681-2199 (United States)

    2006-12-15

    An empirical line-by-line model for the infrared solar transmittance spectrum is presented. The model can be incorporated into radiative transfer codes to allow fast calculation of all relevant emission and absorption features in the solar spectrum in the mid-infrared region from 700 to 5000cm{sup -1}. The transmittance is modelled as a function of the diameter of the field-of-view centered on the solar disk: the line broadening due to solar rotation as well as center-to-limb variations in strength and width are taken into account for stronger lines. Applications of the model presented here are in the fields of terrestrial remote sensing in the mid-infrared spectral region when the sun is used as radiation source or scattered solar radiation contributes to the measured signal and in the fields of atmospheric radiative transfer algorithms which compute the propagation of infrared solar radiation in the terrestrial atmosphere.

  5. Oxygen transfer rate estimation in oxidation ditches from clean water measurements.

    Science.gov (United States)

    Abusam, A; Keesman, K J; Meinema, K; Van Straten, G

    2001-06-01

    Standard methods for the determination of oxygen transfer rate are based on assumptions that are not valid for oxidation ditches. This paper presents a realistic and simple new method to be used in the estimation of oxygen transfer rate in oxidation ditches from clean water measurements. The new method uses a loop-of-CSTRs model, which can be easily incorporated within control algorithms, for modelling oxidation ditches. Further, this method assumes zero oxygen transfer rates (KLa) in the unaerated CSTRs. Application of a formal estimation procedure to real data revealed that the aeration constant (k = KLaVA, where VA is the volume of the aerated CSTR) can be determined significantly more accurately than KLa and VA. Therefore, the new method estimates k instead of KLa. From application to real data, this method proved to be more accurate than the commonly used Dutch standard method (STORA, 1980).

  6. A Measurement of the Angular Power Spectrum of the Microwave Background Made from the High Chilean Andes

    Science.gov (United States)

    Torbet, E.; Devlin, M. J.; Dorwart, W. B.; Herbig, T.; Miller, A. D.; Nolta, M. R.; Page, L.; Puchalla, J.; Tran, H. T.

    1999-08-01

    We report on a measurement of the angular spectrum of the anisotropy of the microwave sky at 30 and 40 GHz between l=50 and l=200. The data, covering roughly 600 deg2, support a rise in the angular spectrum to a maximum with δTl~85 μK at l=200. We also give a 2 σ upper limit of δTlToco, Chile. To assist in assessing the site, we present plots of the fluctuations in atmospheric emission at 30 and 144 GHz.

  7. Automatic detection of health changes using statistical process control techniques on measured transfer times of elderly.

    Science.gov (United States)

    Baldewijns, Greet; Luca, Stijn; Nagels, William; Vanrumste, Bart; Croonenborghs, Tom

    2015-01-01

    It has been shown that gait speed and transfer times are good measures of functional ability in elderly. However, data currently acquired by systems that measure either gait speed or transfer times in the homes of elderly people require manual reviewing by healthcare workers. This reviewing process is time-consuming. To alleviate this burden, this paper proposes the use of statistical process control methods to automatically detect both positive and negative changes in transfer times. Three SPC techniques: tabular CUSUM, standardized CUSUM and EWMA, known for their ability to detect small shifts in the data, are evaluated on simulated transfer times. This analysis shows that EWMA is the best-suited method with a detection accuracy of 82% and an average detection time of 9.64 days.

  8. The Spectrum of the Universe.

    Science.gov (United States)

    Hill, Ryley; Masui, Kiyoshi W; Scott, Douglas

    2018-05-01

    Cosmic background (CB) radiation, encompassing the sum of emission from all sources outside our own Milky Way galaxy across the entire electromagnetic spectrum, is a fundamental phenomenon in observational cosmology. Many experiments have been conceived to measure it (or its constituents) since the extragalactic Universe was first discovered; in addition to estimating the bulk (cosmic monopole) spectrum, directional variations have also been detected over a wide range of wavelengths. Here we gather the most recent of these measurements and discuss the current status of our understanding of the CB from radio to γ-ray energies. Using available data in the literature, we piece together the sky-averaged intensity spectrum and discuss the emission processes responsible for what is observed. We examine the effect of perturbations to the continuum spectrum from atomic and molecular line processes and comment on the detectability of these signals. We also discuss how one could, in principle, obtain a complete census of the CB by measuring the full spectrum of each spherical harmonic expansion coefficient. This set of spectra of multipole moments effectively encodes the entire statistical history of nuclear, atomic, and molecular processes in the Universe.

  9. Implementation of emergency department transfer communication measures in Minnesota critical access hospitals.

    Science.gov (United States)

    Klingner, Jill; Moscovice, Ira; Casey, Michelle; McEllistrem Evenson, Alex

    2015-01-01

    Previously published findings based on field tests indicated that emergency department patient transfer communication measures are feasible and worthwhile to implement in rural hospitals. This study aims to expand those findings by focusing on the wide-scale implementation of these measures in the 79 Critical Access Hospitals (CAHs) in Minnesota from 2011 to 2013. Information was obtained from interviews with key informants involved in implementing the emergency department patient transfer communication measures in Minnesota as part of required statewide quality reporting. The first set of interviews targeted state-level organizations regarding their experiences working with providers. A second set of interviews targeted quality and administrative staff from CAHs regarding their experiences implementing measures. Implementing the measures in Minnesota CAHs proved to be successful in a number of respects, but informants also faced new challenges. Our recommendations, addressed to those seeking to successfully implement these measures in other states, take these challenges into account. Field-testing new quality measure implementations with volunteers may not be indicative of a full-scale implementation that requires facilities to participate. The implementation team's composition, communication efforts, prior relationships with facilities and providers, and experience with data collection and abstraction tools are critical factors in successfully implementing required reporting of quality measures on a wide scale. © 2014 National Rural Health Association.

  10. EXAMINING THE BROADBAND EMISSION SPECTRUM OF WASP-19b: A NEW z-BAND ECLIPSE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, George; Bayliss, Daniel D. R. [Research School of Astronomy and Astrophysics, Australian National University, Cotter Rd, Weston Creek, ACT 2611 (Australia); Kedziora-Chudczer, Lucyna; Bailey, Jeremy, E-mail: george@mso.anu.edu.au [School of Physics, University of New South Wales, Sydney, NSW 2052 (Australia)

    2013-09-10

    WASP-19b is one of the most irradiated hot-Jupiters known. Its secondary eclipse is the deepest of all transiting planets and has been measured in multiple optical and infrared bands. We obtained a z-band eclipse observation with a measured depth of 0.080% {+-} 0.029%, using the 2 m Faulkes Telescope South, which is consistent with the results of previous observations. We combined our measurement of the z-band eclipse with previous observations to explore atmosphere models of WASP-19b that are consistent with its broadband spectrum. We use the VSTAR radiative transfer code to examine the effect of varying pressure-temperature profiles and C/O abundance ratios on the emission spectrum of the planet. We find that models with super-solar carbon enrichment best match the observations, which is consistent with previous model retrieval studies. We also include upper atmosphere haze as another dimension in the interpretation of exoplanet emission spectra and find that particles <0.5 {mu}m in size are unlikely to be present in WASP-19b.

  11. SU-E-T-782: Using Light Output From Doped Plastic Scintillators to Resolve the Linear Energy Transfer Spectrum of Clinical Electron Beams

    International Nuclear Information System (INIS)

    Nusrat, H; Pang, G; Ahmad, S; Keller, B; Sarfehnia, A

    2015-01-01

    Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident

  12. Heat Transfer Analysis and Modification of Thermal Probe for Gas-Solid Measurement

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    2016-01-01

    Full Text Available The presented work aims to measure the gas-solid two-phase mass flow-rate in pneumatic conveyor, and a novel modified thermal probe is applied. A new analysis of the local heat transfer coefficients of thermal probe is presented, while traditional investigations focus on global coefficients. Thermal simulations are performed in Fluent 6.2 and temperature distributions of the probe are presented. The results indicate that the probe has obviously stable and unstable heat transfer areas. Based on understanding of probe characteristics, a modified probe structure is designed, which makes the probe output signal more stable and widens the measuring range. The experiments are carried out in a special designed laboratory scale pneumatic conveyor, and the modified probe shows an unambiguous improvement of the performance compared with the traditional one.

  13. Measurements of the millimeter-wave spectrum of interstellar dust emission

    Science.gov (United States)

    Fischer, M. L.; Clapp, A.; Devlin, M.; Gundersen, J. O.; Lange, A. E.; Lubin, P. M.; Meinhold, P. R.; Richards, P. L.; Smoot, G. F.

    1995-01-01

    We report measurements of the differential brightness of interstellar dust emission near the Galactic plane and at high Galactic latitudes. The data were obtained as part of a program to measure anisotropy in the cosmic microwave background (CMB). The measurements were made with a 0.5 deg beam size and a 1.3 deg sinusoidal chop, in broad bands (Delta nu/nu approximately 0.3) centered near frequencies of 6, 9, and 12 cm(exp -1). A measurement made toward the Galactic plane, at longitude 1 = 23.7 deg, is compared with the contrast observed in the 100 micrometers IRAS data. Assuming the dust emission has a brightness I(sub nu) proportional to nu(sup n)B(sub nu)(T(sub d)), where B(sub nu) is the Planck function, a best fit yields n = 1.6 +/- 0.4, T(sub d) = 24 +/- 5 K. In a region near the star mu Pegasi (mu PEG l = 91 deg, b = -31 deg), the comparison of our data with the 100 micrometers IRAS data yields n = 1.4 +/- 0.4, and T(sub d) = 18 +/- 3 K. In a second region near the star gamma Ursa Minoris (GUM l = 108 deg, b = 41 deg), an upper limit is placed on contrast in dust emission. This upper limit is consistent with spectrum measured at mu PEG and the IRAS 100 micrometer emission contrast at GUM, which is approximately 8 times lower than mu PEG.

  14. [Investigation of multi-wavelength effect during the measurement of UV-enhanced film's emission spectrum].

    Science.gov (United States)

    Liu, Meng; Ni, Zheng-ji; Zhang, Da-wei; Huang, Yuan-shen; Zhuang, Song-lin

    2009-09-01

    The UV-responsive detector is a dual-use device for civilian and military after the laser and IR-responsive sensors. Typical image sensor coated with a layer of down-convert frequency thin film on it's photosurface to enhance UV response is the key technology of enhancing UV-response. The UV-enhanced thin film was made in the experimental laboratory using the Zn2SiO4:Mn phosphor by spin coating method. Two peaks at 520 and 560 nm respectively in the emission spectrum of the UV-enhanced film were found by SP1702 spectrograph when the excitation wavelength was 260 and 280 nm. The peaks were found in the process of experiment of measuring and counting the quantum efficiency of UV-enhanced thin film. But the light peaks at 520 and 560 nm are not the emission light peaks by the exciting light of 260 and 280 nm. The reason why the light at 520 and 560 nm is not the emission light was analyzed based on the measurement principle of grating spectrograph. The reasons for the multi-wavelength of light overlaps during the measurement of emission spectrum were also discussed. And the equipment used to separate the overlapped different wavelengths was designed, which will be used to resolve the problem of the overlap of multi-wavelength.

  15. The measurement of tripartition alpha particle low energy spectrum in 235U fission induced by thermal neutrons

    International Nuclear Information System (INIS)

    El Hage Sleiman, F.

    1980-01-01

    The energy spectrum of the α particles emitted in the thermal neutron induced fission of 235 U was measured from 11.5 MeV down to 2 MeV using the parabola mass spectrometer Lohengrin at the ILL high flux reactor. A Monte Carlo program, that simulates the α particle motion to the spectrometer, has been developed. Numerical results of Monte Carlo calculations for differents values of parameter are reported. The overall energy spectrum is slightly asymmetric at low energy. The possible reasons for the existence of this asymmetry are discussed [fr

  16. Measurement of Cosmic-Ray Antiproton Spectrum at Solar Minimum with a Long-Duration Balloon Flight in Antarctica

    Science.gov (United States)

    Abe, K.; Fuke, H.; Haino, S.; Hams, T.; Hasegawa, M.; Horikoshi, A.; Kim, K. C.; Kusumoto, A.; Lee, M. H.; Makida, Y.; hide

    2011-01-01

    The energy spectrum of cosmic-ray antiprotons (p(raised bar)'s) collected by the BESS-Polar II instrument during a long-duration flight over Antarctica in the solar minimum period of December 2007 through January 2008. The p(raised bar) spectrum measured by BESS-Polar II shows good consistency with secondary p(raised bar) calculations. Cosmologically primary p(raised bar)'s have been searched for by comparing the observed and calculated p(raised bar) spectra. The BESSPolar II result shows no evidence of primary p(raised bar)'s originating from the evaporation of PBH.

  17. Force sensor for measuring power transfer between the human body and the environment

    NARCIS (Netherlands)

    Brookhuis, Robert Anton; Lammerink, Theodorus S.J.; Wiegerink, Remco J.; de Boer, Meint J.; Elwenspoek, Michael Curt

    2011-01-01

    A force sensor with capacitive readout is designed and realized for the measurement of mechanical power transfer. The ultimate aim is to integrate this in a glove that determines the complete mechanical interaction between the human hand and the environment. The sensor measures the normal force and

  18. Backward transfer entropy: Informational measure for detecting hidden Markov models and its interpretations in thermodynamics, gambling and causality

    Science.gov (United States)

    Ito, Sosuke

    2016-01-01

    The transfer entropy is a well-established measure of information flow, which quantifies directed influence between two stochastic time series and has been shown to be useful in a variety fields of science. Here we introduce the transfer entropy of the backward time series called the backward transfer entropy, and show that the backward transfer entropy quantifies how far it is from dynamics to a hidden Markov model. Furthermore, we discuss physical interpretations of the backward transfer entropy in completely different settings of thermodynamics for information processing and the gambling with side information. In both settings of thermodynamics and the gambling, the backward transfer entropy characterizes a possible loss of some benefit, where the conventional transfer entropy characterizes a possible benefit. Our result implies the deep connection between thermodynamics and the gambling in the presence of information flow, and that the backward transfer entropy would be useful as a novel measure of information flow in nonequilibrium thermodynamics, biochemical sciences, economics and statistics. PMID:27833120

  19. Measurement of the amplitude and phase transfer functions of an optical modulator using a heterodyne technique

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2001-01-01

    We present a new technique that measures the full amplitude and phase transfer curves of the modulator as a function of the applied bias, from which the small signal α-parameter can be calculated. The technique measures the amplitude and phase transfer functions simultaneously and directly......, compared to techniques where a time-consuming data analysis is necessary to calculate the a-parameter and an additional measurement is necessary to estimate the phase. Additionally, the chirp profile for all operation points can be calculated....

  20. Measurement of 89Y(n,2n) spectral averaged cross section in LR-0 special core reactor spectrum

    Science.gov (United States)

    Košťál, Michal; Losa, Evžen; Baroň, Petr; Šolc, Jaroslav; Švadlenková, Marie; Koleška, Michal; Mareček, Martin; Uhlíř, Jan

    2017-12-01

    The present paper describes reaction rate measurement of 89Y(n,2n)88Y in a well-defined reactor spectrum of a special core assembled in the LR-0 reactor and compares this value with results of simulation. The reaction rate is derived from the measurement of activity of 88Y using gamma-ray spectrometry of irradiated Y2O3 sample. The resulting cross section value averaged in spectrum is 43.9 ± 1.5 μb, averaged in the 235U spectrum is 0.172 ± 0.006 mb. This cross-section is important as it is used as high energy neutron monitor and is therefore included in the International Reactor Dosimetry and Fusion File. Calculations of reaction rates were performed with the MCNP6 code using ENDF/B-VII.0, JEFF-3.1, JEFF-3.2, JENDL-3.3, JENDL-4, ROSFOND-2010, CENDL-3.1 and IRDFF nuclear data libraries. The agreement with uranium description by CIELO library is very good, while in ENDF/B-VII.0 description of uranium, underprediction about 10% in average can be observed.

  1. THREE-DIMENSIONAL RADIATIVE TRANSFER MODELING OF THE POLARIZATION OF THE SUN'S CONTINUOUS SPECTRUM

    International Nuclear Information System (INIS)

    Bueno, Javier Trujillo; Shchukina, Nataliya

    2009-01-01

    Polarized light provides the most reliable source of information at our disposal for diagnosing the physical properties of astrophysical plasmas, including the three-dimensional (3D) structure of the solar atmosphere. Here we formulate and solve the 3D radiative transfer problem of the linear polarization of the solar continuous radiation, which is principally produced by Rayleigh and Thomson scattering. Our approach takes into account not only the anisotropy of the solar continuum radiation but also the symmetry-breaking effects caused by the horizontal atmospheric inhomogeneities produced by the solar surface convection. We show that such symmetry-breaking effects do produce observable signatures in Q/I and U/I, even at the very center of the solar disk where we observe the forward scattering case, but their detection would require obtaining very high resolution linear polarization images of the solar surface. Without spatial and/or temporal resolution U/I ∼ 0 and the only observable quantity is Q/I, whose wavelength variation at a solar disk position close to the limb has been recently determined semi-empirically. Interestingly, our 3D radiative transfer modeling of the polarization of the Sun's continuous spectrum in a well-known 3D hydrodynamical model of the solar photosphere shows remarkable agreement with the semi-empirical determination, significantly better than that obtained via the use of one-dimensional (1D) atmospheric models. Although this result confirms that the above-mentioned 3D model was indeed a suitable choice for our Hanle-effect estimation of the substantial amount of 'hidden' magnetic energy that is stored in the quiet solar photosphere, we have found however some small discrepancies whose origin may be due to uncertainties in the semi-empirical data and/or in the thermal and density structure of the 3D model. For this reason, we have paid some attention also to other (more familiar) observables, like the center-limb variation of the

  2. High-resolution wave number spectrum using multi-point measurements in space – the Multi-point Signal Resonator (MSR technique

    Directory of Open Access Journals (Sweden)

    Y. Narita

    2011-02-01

    Full Text Available A new analysis method is presented that provides a high-resolution power spectrum in a broad wave number domain based on multi-point measurements. The analysis technique is referred to as the Multi-point Signal Resonator (MSR and it benefits from Capon's minimum variance method for obtaining the proper power spectral density of the signal as well as the MUSIC algorithm (Multiple Signal Classification for considerably reducing the noise part in the spectrum. The mathematical foundation of the analysis method is presented and it is applied to synthetic data as well as Cluster observations of the interplanetary magnetic field. Using the MSR technique for Cluster data we find a wave in the solar wind propagating parallel to the mean magnetic field with relatively small amplitude, which is not identified by the Capon spectrum. The Cluster data analysis shows the potential of the MSR technique for studying waves and turbulence using multi-point measurements.

  3. Use of an improved radiation amplification factor to estimate the effect of total ozone changes on action spectrum weighted irradiances and an instrument response function

    Science.gov (United States)

    Herman, Jay R.

    2010-12-01

    Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone Ω, U(Ω/200)-RAF, where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 nm) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.

  4. Radiative transfer modeling applied to sea water constituent determination. [Gulf of Mexico

    Science.gov (United States)

    Faller, K. H.

    1979-01-01

    Optical radiation from the sea is influenced by pigments dissolved in the water and contained in discrete organisms suspended in the sea, and by pigmented and unpigmented inorganic and organic particles. The problem of extracting the information concerning these pigments and particulates from the optical properties of the sea is addressed and the properties which determine characteristics of the radiation that a remote sensor will detect and measure are considered. The results of the application of the volume scattering function model to the data collected in the Gulf of Mexico and its environs indicate that the size distribution of the concentrations of particles found in the sea can be predicted from measurements of the volume scattering function. Furthermore, with the volume scattering function model and knowledge of the absorption spectra of dissolved pigments, the radiative transfer model can compute a distribution of particle sizes and indices of refraction and concentration of dissolved pigments that give an upwelling light spectrum that closely matches measurements of that spectrum at sea.

  5. The 235U prompt fission neutron spectrum measured by the Chi-Nu project at LANSCE

    Directory of Open Access Journals (Sweden)

    Gomez J.A.

    2017-01-01

    Full Text Available The Chi-Nu experiment aims to accurately measure the prompt fission neutron spectrum for the major actinides. At the Los Alamos Neutron Science Center (LANSCE, fission can be induced with neutrons ranging from 0.7 MeV and above. Using a two arm time-of-flight (TOF technique, the fission neutrons are measured in one of two arrays: a 22-6Li glass array for lower energies, or a 54-liquid scintillator array for outgoing energies of 0.5 MeV and greater. Presented here are the collaboration's preliminary efforts at measuring the 235U PFNS.

  6. The Neutron Spectrum in a Uranium Tube

    International Nuclear Information System (INIS)

    Johansson, E.; Jonsson, E.; Lindberg, M.; Mednis, J.

    1963-10-01

    A series of experimental and theoretical investigations on neutron spectra in lattice cells has been started at the reactor R1. This report gives the results from the first one of these cells - one with a tube of natural -uranium surrounded by heavy water. In the measurements the cell was placed in the central, vertical channel of the reactor. The neutron spectrum from a lead scatterer in the uranium tube - outer diameter 49.2 mm, inner diameter 28.3 mm - was measured with a fast chopper in the energy region 0.01 to 100 eV. Subsidiary measurements indicated that the spectrum in the beam from the lead piece corresponds to the spectrum of the angular flux integrated over all angles. This correspondence is important for the interpretation of the experimental data. The thermal part of the spectrum was found to deviate significantly from a Maxwellian. However, the deviation is not very large, and one could use a Maxwellian, at least to give a rough idea of the hardness of the spectrum. For the present tube the temperature of this Maxwellian was estimated as 90 to 100 deg C above the moderator temperature (33 deg C). In the joining region the rise of the spectrum towards the thermal part is slower than for the cell boundary spectrum, measured earlier. In the epithermal region the limited resolution of the chopper has affected the measurements at the energies of the uranium resonances. However, the shape of the spectrum on the flanks of the first resonance in 238 U (6.68 eV) has been obtained accurately. In the theoretical treatment the THERMOS code with a free gas scattering model has been used. The energy region was 3.06 - 0.00025 eV. The agreement with the measurements is good for the thermal part - possibly the theoretical spectrum is a little softer than the experimental one. In the joining region the results from THERMOS are comparatively high - probably due to the scattering model used

  7. The Neutron Spectrum in a Uranium Tube

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E; Jonsson, E; Lindberg, M; Mednis, J

    1963-10-15

    A series of experimental and theoretical investigations on neutron spectra in lattice cells has been started at the reactor R1. This report gives the results from the first one of these cells - one with a tube of natural -uranium surrounded by heavy water. In the measurements the cell was placed in the central, vertical channel of the reactor. The neutron spectrum from a lead scatterer in the uranium tube - outer diameter 49.2 mm, inner diameter 28.3 mm - was measured with a fast chopper in the energy region 0.01 to 100 eV. Subsidiary measurements indicated that the spectrum in the beam from the lead piece corresponds to the spectrum of the angular flux integrated over all angles. This correspondence is important for the interpretation of the experimental data. The thermal part of the spectrum was found to deviate significantly from a Maxwellian. However, the deviation is not very large, and one could use a Maxwellian, at least to give a rough idea of the hardness of the spectrum. For the present tube the temperature of this Maxwellian was estimated as 90 to 100 deg C above the moderator temperature (33 deg C). In the joining region the rise of the spectrum towards the thermal part is slower than for the cell boundary spectrum, measured earlier. In the epithermal region the limited resolution of the chopper has affected the measurements at the energies of the uranium resonances. However, the shape of the spectrum on the flanks of the first resonance in {sup 238}U (6.68 eV) has been obtained accurately. In the theoretical treatment the THERMOS code with a free gas scattering model has been used. The energy region was 3.06 - 0.00025 eV. The agreement with the measurements is good for the thermal part - possibly the theoretical spectrum is a little softer than the experimental one. In the joining region the results from THERMOS are comparatively high - probably due to the scattering model used.

  8. Tracking Transfer: New Measures of Institutional and State Effectiveness in Helping Community College Students Attain Bachelor's Degrees

    Science.gov (United States)

    Jenkins, Davis; Fink, John

    2016-01-01

    Increasing the effectiveness of two- to four-year college transfer is critical for meeting national goals for college attainment and promoting upward social mobility. Efforts to improve institutional effectiveness in serving transfer students and state transfer policy have been hampered by a lack of comparable metrics for measuring transfer…

  9. The Spectrum and Term Analysis of Co III Measured Using Fourier Transform and Grating Spectroscopy

    Science.gov (United States)

    Smillie, D. G.; Pickering, J. C.; Nave, G.; Smith, P. L.

    2016-03-01

    The spectrum of Co III has been recorded in the region 1562-2564 Å (64,000 cm-1-39,000 cm-1) by Fourier transform (FT) spectroscopy, and in the region 1317-2500 Å (164,000 cm-1-40,000 cm-1) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt-neon Penning discharge lamp. We classified 514 Co III lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm-1 (approximately 0.2 mÅ at 2000 Å, or 1 part in 107), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen & Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d64s and almost half of the 3d64p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

  10. Headphone-To-Ear Transfer Function Estimation Using Measured Acoustic Parameters

    Directory of Open Access Journals (Sweden)

    Jinlin Liu

    2018-06-01

    Full Text Available This paper proposes to use an optimal five-microphone array method to measure the headphone acoustic reflectance and equivalent sound sources needed in the estimation of headphone-to-ear transfer functions (HpTFs. The performance of this method is theoretically analyzed and experimentally investigated. With the measured acoustic parameters HpTFs for different headphones and ear canal area functions are estimated based on a computational acoustic model. The estimation results show that HpTFs vary considerably with headphones and ear canals, which suggests that individualized compensations for HpTFs are necessary for headphones to reproduce desired sounds for different listeners.

  11. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; van Dam, H.; Kleiss, E.B.J.; van Uitert, G.C.; Veldhuis, D.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations.

  12. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations. (author)

  13. Sequential measurements of cosmic-ray neutron spectrum and dose rate at sea level in Sendai, Japan

    International Nuclear Information System (INIS)

    Nakamura, Takashi; Nunomiya, Tomoya; Abe, Shigeru; Terunuma, Kazutaka; Suzuki, Hiroyuki

    2005-01-01

    The cosmic-ray neutron energy spectrum and dose rate were measured sequentially for two years from April 2001 up to March 2003 by using three neutron detectors, a 3 He-loaded multi-moderator detector (Bonner ball), 12.7 cm diameter by 12.7 cm long NE213 organic liquid scintillator, and high-sensitivity rem (dose equivalent) counter at the Kawauchi campus of Tohoku University in Sendai, Japan of geomagnetic latitude, 29degN, and cutoff rigidity, 10.43 GV. The neutron spectrum has three major peaks, thermal energy peak, evaporation peak around 1 MeV and cascade peak around 100 MeV. The ambient neutron dose equivalent rates measured by the rem counter, and the Bonner ball keep almost constant values of 4.0 and 6.5 (nSv/h), respectively, throughout this time period, after atmospheric pressure correction, and it often decreased about 30% after a large Solar Flare, that is called as the Forbush decrease. The total neutron flux was also obtained by the Bonner ball measurements to be 7.5x10 -3 (ncm -2 ·s -1 ) in average. The altitude variation of neutron flux and dose was also investigated by comparing the measured results with other results measured at Mt. Fuji area and aboard an airplane, where the cutoff rigidities are similar. (author)

  14. Measurement of condensation heat transfer coefficients in a steam chamber using a variable conductance heat pipe

    International Nuclear Information System (INIS)

    Robinson, J.A.; Windebank, S.R.

    1988-01-01

    Condensation heat transfer coefficients have been measured in a pressurised chamber containing a mixture of saturated steam and air. They were determined as a function of the air-steam ratio in nominally stagnant conditions. The effect of pressure is assessed and preliminary measurements with a forced convective component of velocity are presented. A novel measurement technique was adopted, namely to use a vertical heat pipe whose conductance could easily be varied. It transported heat from an evaporator located inside the chamber to a condenser section outside, at which the heat flow was measured. Heat flux at the evaporator could then be determined and a condensation heat transfer coefficient derived. The range of coefficients covered was from 150 W/m 2 0 K at high air-steam ratios to 20,000 W/m 2 0 K in pure steam. Results show that increasing either total pressure or velocity enhances condensation heat transfer over the range of air/steam ratios considered. (author)

  15. Measuring the low-energy cosmic ray spectrum with the AFIS detector

    Energy Technology Data Exchange (ETDEWEB)

    Losekamm, Martin [Physics Department E18, Technische Universitaet Muenchen (Germany); Institute of Astronautics, Technische Universitaet Muenchen (Germany); Gaisbauer, Dominic; Greenwald, Daniel; Hahn, Alexander; Hauptmann, Philipp; Konorov, Igor; Meng, Lingxin; Paul, Stephan; Poeschl, Thomas [Physics Department E18, Technische Universitaet Muenchen (Germany); Renker, Dieter [Physics Department E17, Technische Universitaet Muenchen (Germany)

    2014-07-01

    High-energy cosmic rays interact with Earth's upper atmosphere and produce antiprotons, which can be trapped in Earth's magnetic field. The Antiproton Flux in Space (AFIS) Mission will measure the flux of trapped antiprotons with energies less than 100 MeV aboard the nanosatellite MOVE 2. An active-target tracking detector comprised of scintillating plastic fibers and silicon photomultipliers is already under construction at the Technische Universitaet Muenchen. As a precursor to the space-bound mission, a prototype version of the detector will be launched aboard a balloon from Kiruna, Sweden as part of the REXUS/BEXUS student program by the German Aerospace Center (DLR). Named AFIS-P, it will be used to measure the low-energy part of the cosmic-ray spectrum for energies less than 100 MeV-per-nucleon. Spectrometers in previous balloon missions were not sensitive in this low-energy region. Thus AFIS-P will deliver unprecedented data, while simultaneously allowing us to field-test the AFIS detector.

  16. Measurement of cross sections of threshold detectors with spectrum average technique

    International Nuclear Information System (INIS)

    Agus, Y.; Celenk, I.; Oezmen, A.

    2004-01-01

    Cross sections of the reactions 103 Rh(n, n') 103m Rh, 115 In(n, n') 115m In, 232 Th(n, f), 47 Ti(n, p) 47 Sc, 64 Zn(n, p) 64 Cu, 58 Ni(n, p) 58 Co, 54 Fe(n, p) 54 Mn, 46 Ti(n, p) 46 Sc, 27 Al(n, p) 27 Mg, 56 Fe(n, p) 56 Mn, 24 Mg(n, p) 24 Na, 59 Co(n, α) 56 Mn, 27 Al(n, α) 24 Na and 48 Ti(n, p) 48 Sc were measured with average neutron energies above effective threshold by using the activation method through usage of spectrum average technique in an irradiation system where there are three equivalent Am/Be sources, each of which has 592 GBq activity. The cross sections were determined with reference to the fast neutron fission cross section of 238 U. The measured values and published values are generally in agreement. (orig.)

  17. Apparatus intended for measuring heat capacity and heat transfer down to mK range

    International Nuclear Information System (INIS)

    Hebral, B.; Frossati, G.; Godfrin, H.; Schumacher, G.; Thoulouze, D.

    1978-01-01

    A cryogenic apparatus to perform heat capacity and heat transfer measurements in the range 1.5 mK-50 mK is described. Measurements are performed in an adiabatic demagnetization cell attached to a dilution refrigerator. Heat capacity measurements were effected on CMN-helium systems; the CMN specific heat was deduced above 1.6 mK when using liquid 3 He or a mixture 1.1% 3 He - 98.9% 4 He. A specific heat anomaly was observed with 4 He below 10 mK. It does not seen possible to interprete it by simple thermal equilibrium considerations. The superfluid 3 He heat capacity was also deduced from the results obtained with liquid 3 He under pressure. In heat transfer measurements at the interface CMN-mixture 3 He- 4 He, the temperature dependence of the thermal boundary resistance is in rather good agreement with other powder results. The measured resistances are larger than those predicted by the classical phonon process [fr

  18. What next-generation 21 cm power spectrum measurements can teach us about the epoch of reionization

    International Nuclear Information System (INIS)

    Pober, Jonathan C.; Morales, Miguel F.; Liu, Adrian; McQuinn, Matthew; Parsons, Aaron R.; Dillon, Joshua S.; Hewitt, Jacqueline N.; Tegmark, Max; Aguirre, James E.; Bowman, Judd D.; Jacobs, Daniel C.; Bradley, Richard F.; Carilli, Chris L.; DeBoer, David R.; Werthimer, Dan J.

    2014-01-01

    A number of experiments are currently working toward a measurement of the 21 cm signal from the epoch of reionization (EoR). Whether or not these experiments deliver a detection of cosmological emission, their limited sensitivity will prevent them from providing detailed information about the astrophysics of reionization. In this work, we consider what types of measurements will be enabled by the next generation of larger 21 cm EoR telescopes. To calculate the type of constraints that will be possible with such arrays, we use simple models for the instrument, foreground emission, and the reionization history. We focus primarily on an instrument modeled after the ∼0.1 km 2 collecting area Hydrogen Epoch of Reionization Array concept design and parameterize the uncertainties with regard to foreground emission by considering different limits to the recently described 'wedge' footprint in k space. Uncertainties in the reionization history are accounted for using a series of simulations that vary the ionizing efficiency and minimum virial temperature of the galaxies responsible for reionization, as well as the mean free path of ionizing photons through the intergalactic medium. Given various combinations of models, we consider the significance of the possible power spectrum detections, the ability to trace the power spectrum evolution versus redshift, the detectability of salient power spectrum features, and the achievable level of quantitative constraints on astrophysical parameters. Ultimately, we find that 0.1 km 2 of collecting area is enough to ensure a very high significance (≳ 30σ) detection of the reionization power spectrum in even the most pessimistic scenarios. This sensitivity should allow for meaningful constraints on the reionization history and astrophysical parameters, especially if foreground subtraction techniques can be improved and successfully implemented.

  19. Parents Suggest Which Indicators of Progress and Outcomes Should Be Measured in Young Children with Autism Spectrum Disorder

    Science.gov (United States)

    McConachie, Helen; Livingstone, Nuala; Morris, Christopher; Beresford, Bryony; Le Couteur, Ann; Gringras, Paul; Garland, Deborah; Jones, Glenys; Macdonald, Geraldine; Williams, Katrina; Parr, Jeremy R.

    2018-01-01

    Evaluation of interventions for children with autism spectrum disorder (ASD) is hampered by the multitude of outcomes measured and tools used. Measurement in research with young children tends to focus on core impairments in ASD. We conducted a systematic review of qualitative studies of what matters to parents. Parent advisory groups completed…

  20. New measurements in plutonium L X ray emission spectrum using an electron probe micro-analyser

    International Nuclear Information System (INIS)

    Bobin, J.L.; Despres, J.

    1966-01-01

    Further studies by means of an electron-probe micro-analyser, allowed report CEA-R--1798 authors to set up a larger plutonium X ray spectrum table. Measurements of plutonium L II and L III levels excitation potentials have also been achieved. Some remarks about apparatus performance data (such as spectrograph sensibility, resolving power and accuracy) will be found in the appendix. (authors) [fr

  1. Heat transfer including radiation and slag particles evolution in MHD channel-I

    International Nuclear Information System (INIS)

    Im, K.H.; Ahluwalia, R.K.

    1980-01-01

    Accurate estimates of convective and radiative heat transfer in the magnetohydrodynamic channel are provided. Calculations performed for a base load-size channel indicate that heat transfer by gas radiation almost equals that by convection for smooth walls, and amounts to 70% as much as the convective heat transfer for rough walls. Carbon dioxide, water vapor, and potassium atoms are the principal participating gases. The evolution of slag particles by homogeneous nucleation and condensation is also investigated. The particle-size spectrum so computed is later utilized to analyze the radiation enhancement by slag particles in the MHD diffuser. The impact of the slag particle spectrum on the selection of a workable and design of an efficient seed collection system is discussed

  2. Localized radio frequency communication using asynchronous transfer mode protocol

    Science.gov (United States)

    Witzke, Edward L.; Robertson, Perry J.; Pierson, Lyndon G.

    2007-08-14

    A localized wireless communication system for communication between a plurality of circuit boards, and between electronic components on the circuit boards. Transceivers are located on each circuit board and electronic component. The transceivers communicate with one another over spread spectrum radio frequencies. An asynchronous transfer mode protocol controls communication flow with asynchronous transfer mode switches located on the circuit boards.

  3. Charge transfer to a dielectric target by guided ionization waves using electric field measurements

    NARCIS (Netherlands)

    Slikboer, E.T.; Garcia-Caurel, E.; Guaitella, O.; Sobota, A.

    2017-01-01

    A kHz-operated atmospheric pressure plasma jet is investigated by measuring charge transferred to a dielectric electro-optic surface (BSO crystal) allowing for the measurement of electric field by exploiting the Pockels effect. The electric field values, distribution of the surface discharge and

  4. Real time spectrum analysis

    International Nuclear Information System (INIS)

    Blunden, A.; O'Prey, D.G.; Tait, W.H.

    1983-01-01

    A method is described for the separation of a composite pulse-height spectrum into its unresolved component parts, which belong to a set of measured library spectra. The method allows real-time estimation giving running estimates during acquisition of the spectrum, minimises computation space, especially for a number of parallel calculations, estimates in advance the rms errors, and produces a significance measure for the hypothesis that the composite contains only the library spectra. Least squares curve-fitting, and other methods, can be compared, with the formalism developed, allowing analytical comparison of the effect of detector energy resolution and detection efficiency. A rational basis for the choice between the various methods of spectrum analysis follows from the theory, minimising rms estimation errors. The method described is applicable for very low numbers of counts and poor resolution. (orig.)

  5. The results of the measurements of mass- and heat-transfer in the wet cooling tower

    International Nuclear Information System (INIS)

    Fabjan, Lj.; Gaspersic, B.

    1979-01-01

    These are the results of our investigations carried out on a packing inside a wet cooling tower for the purpose of studying the mass and heat transfer at the counterflow of water and humid air. The measurements on the experimental tower of the corresponding mathematical model reflect the average coefficient of mass and heat transfer for the unity of the active volume. Further the measurements of pressure drop at the air flow were carried out and thus the coefficient of aerodynamic losses were obtained. The results of measurements are given in the corresponding equations with the dimensionless numbers and diagrams. They will be of great use for the planning of new cooling towers. (author)

  6. THE SPECTRUM AND TERM ANALYSIS OF CO iii MEASURED USING FOURIER TRANSFORM AND GRATING SPECTROSCOPY

    Energy Technology Data Exchange (ETDEWEB)

    Smillie, D. G.; Pickering, J. C. [Blackett Laboratory, Imperial College London, London SW7 2AZ (United Kingdom); Nave, G. [National Institute of Standards and Technology, Gaithersburg, MD 20899-8422 (United States); Smith, P. L., E-mail: j.pickering@imperial.ac.uk [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2016-03-15

    The spectrum of Co iii has been recorded in the region 1562–2564 Å (64,000 cm{sup −1}–39,000 cm{sup −1}) by Fourier transform (FT) spectroscopy, and in the region 1317–2500 Å (164,000 cm{sup −1}–40,000 cm{sup −1}) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt–neon Penning discharge lamp. We classified 514 Co iii lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm{sup −1} (approximately 0.2 mÅ at 2000 Å, or 1 part in 10{sup 7}), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen and Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d{sup 6}4s and almost half of the 3d{sup 6}4p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

  7. UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; William H. Morrison

    2014-03-01

    Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of

  8. Emission Spectrum Property of Modulated Atom-Field Coupling System

    International Nuclear Information System (INIS)

    Gao Yun-Feng; Feng Jian; Li Yue-Ke

    2013-01-01

    The emission spectrum of a two-level atom interacting with a single mode radiation field in the case of periodic oscillation coupling coefficient is investigated. A general expression for the emission spectrum is derived. The numerical results for the initial field in pure number stare are calculated. It is found that the effect of the coupling coefficient modulation on the spectral structure is very obvious in the case of a low modulation frequency and larger amplitude when the initial field is vacuum, which is potentially useful for exploring a modulated light source. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  9. A nanogenerator as a self-powered sensor for measuring the vibration spectrum of a drum membrane

    Science.gov (United States)

    Yu, Aifang; Zhao, Yong; Jiang, Peng; Wang, Zhong Lin

    2013-02-01

    A nanogenerator (NG) is a device that converts vibration energy into electricity. Here, a flexible, small size and lightweight NG is successfully demonstrated as an active sensor for detecting the vibration spectrum of a drum membrane without the use of an external power source. The output current/voltage signal of the NG is a direct measure of the strain of the local vibrating drum membrane that contains rich informational content, such as, notably, the vibration frequency, vibration speed and vibration amplitude. In comparison to the laser vibrometer, which is excessively complex and expensive, this kind of small and low cost sensor based on an NG is also capable of detecting the local vibration frequency of a drum membrane accurately. A spatial arrangement of the NGs on the membrane can provide position-dependent vibration information on the surface. The measured frequency spectrum can be understood on the basis of the theoretically calculated vibration modes. This work expands the application of NGs and reveals the potential for developing sound wave detection, environmental/infrastructure monitoring and many more applications.

  10. Measurement and analysis of noise power spectrum of computerized tomography in images

    International Nuclear Information System (INIS)

    Castro Tejero, P.; Garayoa Roca, J.

    2013-01-01

    This paper examines the implementation of the spectrum of powers of the noise, NPS, as metric to characterize the noise, both in magnitude and in texture, for CT scans. The NPS found show that you for convolution filters that assume a greater softening in the reconstructed image, spectrum is concentrated in the low frequencies, while for filters sharp, the spectrum extends to high frequencies. In the analyzed cases, there is a low frequency component, largely due to the structure-borne noise, which can be a potential negative effect on the detectability of injuries. (Author)

  11. In vivo 31P nuclear magnetic resonance saturation transfer measurements of phosphate exchange reactions in the yeast Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Campbell, S.L.; Jones, K.A.; Schulman, R.G.

    1985-01-01

    31 P saturation transfer techniques have been used to measure phosphate kinetics in the yeast Saccharomyces cerevisiae. The phosphate comsumption rate observed in acetate grown mid-log cells was combined with measurements of O 2 consumption to yield P/O ratios of 2.2 and 2.9, for cells respiring on glucose and ethanol, respectively. However, no phosphate consumption activity was observed in saturation transfer experiments on anaerobic glucose fed cells. The phosphate consumption rates measured by saturation transfer in cells respiring on glucose and ethanol was attributed to the unidirectional rates of mitochondrial ATP synthesis. (Auth.)

  12. Convective Heat Transfer at the Martian Boundary Layer, Measurement and Model

    Science.gov (United States)

    Tomás Soria-Salinas, Álvaro; Zorzano-Mier, María Paz; Martín-Torres, Javier

    2016-04-01

    We present a measuring concept to measure the convective heat transfer coefficient h near a spacecraft operating on the surface of Mars. This coefficient can be used to derive the speed of the wind and direction, and to detect its modulations. This measuring concept will be used in the instrument HABIT (HabitAbility: Brines, Irradiance and Temperature) for the Surface Platform of ExoMars 2018 (ESA-Roscosmos). The method is based on the use of 3 Resistance Temperature Thermodetectors (RTD) that measure the temperature at 3 locations along the axial direction of a rod of length L: at the base of the rod, Tb, an intermediate point x = L/n, TLn, and the tip,Ta. This sensing fin is called the Air Temperature Sensor (ATS). HABIT shall incorporate three ATS, oriented in perpendicular directions and thus exposed to wind in a different way. Solving these equations for each ATS, provides three fluid temperatures Tf as well as three m parameters that are used to derive three heat transfer coefficients h. This magnitude is dependent on the local forced convection and therefore is sensitive to the direction, speed and modulations of the wind. The m-parameter has already proven to be useful to investigate the convective activity at the planetary boundary layer on Mars and to determine the height of the planetary boundary layer. This method shall be presented here by: 1) Introducing the mathematical concepts for the retrieval of the m-parameter; 2) performing ANSYS simulations of the fluid dynamics and the thermal environment around the ATS-rods under wind conditions in Mars; and 3) comparing the method by using data measurements from the Rover Environmental Monitoring Station (REMS) at the Curiosity rover of NASA's Mars Science Laboratory project currently operating on Mars. The results shall be compared with the wind sensor measurements of three years of REMS operation on Mars.

  13. Measuring extensive air showers with Cherenkov light detectors of the Yakutsk array: the energy spectrum of cosmic rays

    International Nuclear Information System (INIS)

    Ivanov, A A; Knurenko, S P; Sleptsov, I Ye

    2009-01-01

    The energy spectrum of cosmic rays in the range E∼10 15 eV to 6x10 19 eV is studied in this paper using air Cherenkov light detectors of the Yakutsk array. The total flux of photons produced by the relativistic electrons (including positrons as well, hereafter) of extensive air showers in the atmosphere is used as an energy estimator of the primary particle initiating a shower. The resultant differential flux of cosmic rays exhibits, in agreement with previous measurements, a knee and ankle feature at energies of 3x10 15 and ∼10 19 eV, respectively. A comparison of observational data with simulations is made in the knee and ankle regions in order to choose the models of galactic and extragalactic components of cosmic rays that describe well the energy spectrum measured.

  14. Measuring extensive air showers with Cherenkov light detectors of the Yakutsk array: the energy spectrum of cosmic rays

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A A; Knurenko, S P; Sleptsov, I Ye [Shafer Institute for Cosmophysical Research and Aeronomy, Yakutsk 677980 (Russian Federation)], E-mail: ivanov@ikfia.ysn.ru

    2009-06-15

    The energy spectrum of cosmic rays in the range E{approx}10{sup 15} eV to 6x10{sup 19} eV is studied in this paper using air Cherenkov light detectors of the Yakutsk array. The total flux of photons produced by the relativistic electrons (including positrons as well, hereafter) of extensive air showers in the atmosphere is used as an energy estimator of the primary particle initiating a shower. The resultant differential flux of cosmic rays exhibits, in agreement with previous measurements, a knee and ankle feature at energies of 3x10{sup 15} and {approx}10{sup 19} eV, respectively. A comparison of observational data with simulations is made in the knee and ankle regions in order to choose the models of galactic and extragalactic components of cosmic rays that describe well the energy spectrum measured.

  15. Methodology of heat transfer and flow resistance measurement for matrices of rotating regenerative heat exchangers

    Directory of Open Access Journals (Sweden)

    Butrymowicz Dariusz

    2016-09-01

    Full Text Available The theoretical basis for the indirect measurement approach of mean heat transfer coefficient for the packed bed based on the modified single blow technique was presented and discussed in the paper. The methodology of this measurement approach dedicated to the matrix of the rotating regenerative gas heater was discussed in detail. The testing stand consisted of a dedicated experimental tunnel with auxiliary equipment and a measurement system are presented. Selected experimental results are presented and discussed for selected types of matrices of regenerative air preheaters for the wide range of Reynolds number of gas. The agreement between the theoretically predicted and measured temperature profiles was demonstrated. The exemplary dimensionless relationships between Colburn heat transfer factor, Darcy flow resistance factor and Reynolds number were presented for the investigated matrices of the regenerative gas heater.

  16. Patient Transfers and Risk of Back Injury: Protocol for a Prospective Cohort Study With Technical Measurements of Exposure.

    Science.gov (United States)

    Vinstrup, Jonas; Madeleine, Pascal; Jakobsen, Markus Due; Jay, Kenneth; Andersen, Lars Louis

    2017-11-08

    More than one third of nurses experience musculoskeletal pain several times during a normal work week. Consistent use of assistive devices during patient transfers is associated with a lower risk of occupational back injuries and low back pain (LBP). While uncertainties exist regarding which type of assistive devices most efficiently prevent LBP, exposure assessments using technological advancements allow for quantification of muscle load and body positions during common work tasks. The main objectives of this study are (1) to quantify low back and neck/shoulder muscle load in Danish nurses during patient transfers performed with different types of assistive devices, and (2) to combine the exposure profile for each type of assistive device with fortnightly questionnaires to identify the importance of muscle load (intensity and frequency of transfers) and body position (degree of back inclination and frequency) on LBP intensity and risk of back injury during a patient transfer. A combination of technical measurements (n=50) and a prospective study design (n=2000) will be applied on a cohort of female nurses in Danish hospitals. The technical measurements will be comprised of surface electromyography and accelerometers, with the aim of quantifying muscle load and body positions during various patient transfers, including different types of assistive devices throughout a workday. The study will thereby gather measurements during real-life working conditions. The prospective cohort study will consist of questionnaires at baseline and 1-year follow-up, as well as follow-up via email every other week for one year on questions regarding the frequency of patient transfers, use of assistive devices, intensity of LBP, and back injuries related to patient transfers. The objective measurements on muscle load and body positions during patient handlings will be applied to the fortnightly replies regarding frequency of patient transfer and use of different assistive devices, in

  17. Calibration transfer between electronic nose systems for rapid In situ measurement of pulp and paper industry emissions

    Energy Technology Data Exchange (ETDEWEB)

    Deshmukh, Sharvari [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata (India); Kamde, Kalyani [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Jana, Arun [Center for Development of Advance Computing, Kolkata (India); Korde, Sanjivani [CSIR-National Environmental Engineering and Research Institute, Nagpur (India); Bandyopadhyay, Rajib [Department of Instrumentation and Electronics Engineering, Jadavpur University, Kolkata (India); Sankar, Ravi [Center for Development of Advance Computing, Kolkata (India); Bhattacharyya, Nabarun, E-mail: nabarun.bhattacharya@cdac.in [Center for Development of Advance Computing, Kolkata (India); Pandey, R.A., E-mail: ra_pandey@neeri.res.in [CSIR-National Environmental Engineering and Research Institute, Nagpur (India)

    2014-09-02

    Highlights: • E-nose developed for obnoxious emissions measurement at pulp and paper industrial site. • ANN model developed for prediction of (CH{sub 3}){sub 2}S, (CH{sub 3}){sub 2}S{sub 2}, CH{sub 3}SH and H{sub 2}S concentration. • Calibration transfer methodology developed for transfer between two e-nose instruments. • Box–Behnken design and robust regression used for calibration transfer. • Results show effective transfer of training model from one e-nose system to other. - Abstract: Electronic nose systems when deployed in network mesh can effectively provide a low budget and onsite solution for the industrial obnoxious gaseous measurement. For accurate and identical prediction capability by all the electronic nose systems, a reliable calibration transfer model needs to be implemented in order to overcome the inherent sensor array variability. In this work, robust regression (RR) is used for calibration transfer between two electronic nose systems using a Box–Behnken (BB) design. Out of the two electronic nose systems, one was trained using industrial gas samples by four artificial neural network models, for the measurement of obnoxious odours emitted from pulp and paper industries. The emissions constitute mainly of hydrogen sulphide (H{sub 2}S), methyl mercaptan (MM), dimethyl sulphide (DMS) and dimethyl disulphide (DMDS) in different proportions. A Box–Behnken design consisting of 27 experiment sets based on synthetic gas combinations of H{sub 2}S, MM, DMS and DMDS, were conducted for calibration transfer between two identical electronic nose systems. Identical sensors on both the systems were mapped and the prediction models developed using ANN were then transferred to the second system using BB–RR methodology. The results showed successful transmission of prediction models developed for one system to other system, with the mean absolute error between the actual and predicted concentration of analytes in mg L{sup −1} after calibration

  18. Calibration transfer between electronic nose systems for rapid In situ measurement of pulp and paper industry emissions

    International Nuclear Information System (INIS)

    Deshmukh, Sharvari; Kamde, Kalyani; Jana, Arun; Korde, Sanjivani; Bandyopadhyay, Rajib; Sankar, Ravi; Bhattacharyya, Nabarun; Pandey, R.A.

    2014-01-01

    Highlights: • E-nose developed for obnoxious emissions measurement at pulp and paper industrial site. • ANN model developed for prediction of (CH 3 ) 2 S, (CH 3 ) 2 S 2 , CH 3 SH and H 2 S concentration. • Calibration transfer methodology developed for transfer between two e-nose instruments. • Box–Behnken design and robust regression used for calibration transfer. • Results show effective transfer of training model from one e-nose system to other. - Abstract: Electronic nose systems when deployed in network mesh can effectively provide a low budget and onsite solution for the industrial obnoxious gaseous measurement. For accurate and identical prediction capability by all the electronic nose systems, a reliable calibration transfer model needs to be implemented in order to overcome the inherent sensor array variability. In this work, robust regression (RR) is used for calibration transfer between two electronic nose systems using a Box–Behnken (BB) design. Out of the two electronic nose systems, one was trained using industrial gas samples by four artificial neural network models, for the measurement of obnoxious odours emitted from pulp and paper industries. The emissions constitute mainly of hydrogen sulphide (H 2 S), methyl mercaptan (MM), dimethyl sulphide (DMS) and dimethyl disulphide (DMDS) in different proportions. A Box–Behnken design consisting of 27 experiment sets based on synthetic gas combinations of H 2 S, MM, DMS and DMDS, were conducted for calibration transfer between two identical electronic nose systems. Identical sensors on both the systems were mapped and the prediction models developed using ANN were then transferred to the second system using BB–RR methodology. The results showed successful transmission of prediction models developed for one system to other system, with the mean absolute error between the actual and predicted concentration of analytes in mg L −1 after calibration transfer (on second system) being 0.076, 0

  19. Average cross section measurements in U-235 fission neutron spectrum for some threshold reactions

    International Nuclear Information System (INIS)

    Maidana, N.L.

    1993-01-01

    The average cross section in the 235 U fission spectrum has been measured by the activation technique, for the following thresholds reactions: 115 In(n,n') 115m In, 232 Th(n,f) P.F., 46 , 47 , 48 Ti(n,p) 46,47 , 48 Sc, 55 Mn(n,2 n) 54 Mn, 51 V(n,α) 48 Sc, 90 Zr(n,2 n) 89 Zr, 93 Nb(n,2 n) 92m Nb, 58 Ni(n,2 n) 57 Ni, 24 Mg(n,p) 24 Na, 56 Fe(n,p) 56 Mn, 59 Co(n,α) 56 Mn and 63 Cu(n,α) 60 Co. The activation foils were irradiated close (∼ 4 mm) to the core of the IEA-R1 research reactor in the IPEN-CNEN/SP. The reactor was operated at 2 MW yielding a fast neutron flux around 5 x 10 12 n.cm -2 . s -1 . The neutron flux density was monitored by activation reactions with well known averaged cross sections and with effective thresholds above 1 MeV. The foil activities were measured in a calibrated HPGe spectrometer. The neutron spectrum has been calculated using the SAIPS unfolding system applied to the activation data. A detailed error analysis was performed using the covariance matrix methodology. The results were compared with those from other authors. (author)

  20. A new way of soft X-ray spectrum measurement in the HL-2A tokamak

    International Nuclear Information System (INIS)

    Liao Min; Chen Liaoyuan; Song Xianying; Li Yongge; Luo Cuiwen; Pan Wei; Pan Li

    2007-01-01

    A soft X-ray spectrum measurement system is newly developed for the real-time acquisition, data processing and display of electron temperature. In this system, a personal computer with high-speed A/D acquisition card is used to obtain the original analog data and processing software is specially developed to calculate the electron temperature. Compared with PHA (Pulse Height Analyzer), the new system provides a way to set channel number and time solution by software. This method has been applied in the HL-2A tokamak experiment, and the result shows a good agreement with the electron temperature tested by other measurements. (authors)

  1. Measurement of the proton form factor ratio at low momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Moshe [Hebrew Univ. of Jerusalem (Israel)

    2016-08-01

    Experiment E08-007-II measured the proton elastic form factor ratio μGE=GM in the momentum transfer range of Q2 ~ 0.02 - 0.08 GeV2, the lowest ever measured by polarization transfer techniques. The experiment was performed at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia, USA during 2012. A polarized electron beam with energies of 1.1, 1.7, and 2.2 GeV was elastically scattered off a polarized solid NH3 target. The asymmetries between the cross section of positive and negative helicity states of the beam were determined. These asymmetries can be used to determine the form factor ratio. In this thesis, we present the asymmetry analysis of the experiment, discuss the main challenges and show preliminary results for part of the data. Preliminary asymmetries indicate an increase in the form factor ratio above unity. However, a complete analysis is required before any conclusion can be made. Further analysis is ongoing, and final asymmetry results and form factor extraction is expected during 2017. We also present first results for 14N asymmetries for elastic and quasi-elastic scattering. The measured asymmetries are in agreement with the shell model approximation, within the low accuracy of the measurement. A change in the asymmetry sign between the elastic and the quasi-elastic processes is seen, and should motivate further theoretical studies. These experimental asymmetries will also be useful for systematic studies of other experiments using polarized NH3 targets.

  2. Determination of central q and effective mass on textor based on discrete Alfven wave (DAW) spectrum measurements

    International Nuclear Information System (INIS)

    Descamps, P.; Wassenhove, G. van; Koch, R.; Messiaen, A.M.; Vandenplas, P.E.; Lister, J.B.; Marmillod, P.

    1990-01-01

    The use of the discrete Alfven wave spectrum to determine the current density profile and the effective mass density of the plasma in the TEXTOR tokamak is studied; the measurement, the validity of which is discussed, confirms independently the central q(r=0)<1 already obtained by polarimetry. (orig.)

  3. [The Effect of Observation Geometry on Polarized Skylight Spectrum].

    Science.gov (United States)

    Zhang, Ren-bin; Wang, Ling-mei; Gao, Jun; Wang, Chi

    2015-03-01

    Study on polarized skylight spectral characters while observation geometry changing in different solar zenith angles (SZA), viewing zenith angles (VZA) or relative azimuth angles (RAA). Simulation calculation of cloudless daylight polarimetric spectrum is realized based on the solver, vector discrete ordinate method, of radiative transfer equation. In the Sun's principal and perpendicular plane, the spectral irradiance data, varying at wavelengths in the range between 0.4 and 3 μm, are calculated to extend the atmospheric polarization spectral information under the conditions: the MODTRAN solar reference spectrur is the only illuminant source; the main influencing factors of polarized radiative transfer include underlying surface albedo, aerosol layers and components, and the absorption of trace gases. Simulation analysis results: (1) While the relative azimuth angle is zero, the magnitude of spectrum U/I is lower than 10(-7) and V/I is negligible, the degree of polarization and the spectrum Q/I are shaped like the letter V or mirror-writing U. (2) In twilight, when the Sun is not in FOV of the detector, the polarization of the daytime sky has two maximum near 0.51 and 2.75 μm, and a minimum near 1.5 μm. For arbitrary observation geometry, the spectral signal of V/I may be ignored. According to observation geometry, choosing different spectral bands or polarized signal will be propitious to targets detection.

  4. Measurement of subcooled boiling pressure drop and local heat transfer coefficient in horizontal tube under LPLF conditions

    International Nuclear Information System (INIS)

    Baburajan, P.K.; Bisht, G.S.; Gupta, S.K.; Prabhu, S.V.

    2013-01-01

    Highlights: ► Measured subcooled boiling pressure drop and local heat transfer coefficient in horizontal tubes. ► Infra-red thermal imaging is used for wall temperature measurement. ► Developed correlations for pressure drop and local heat transfer coefficient. -- Abstract: Horizontal flow is commonly encountered in boiler tubes, refrigerating equipments and nuclear reactor fuel channels of pressurized heavy water reactors (PHWR). Study of horizontal flow under low pressure and low flow (LPLF) conditions is important in understanding the nuclear core behavior during situations like LOCA (loss of coolant accidents). In the present work, local heat transfer coefficient and pressure drop are measured in a horizontal tube under LPLF conditions of subcooled boiling. Geometrical parameters covered in this study are diameter (5.5 mm, 7.5 mm and 9.5 mm) and length (550 mm, 750 mm and 1000 mm). The operating parameters varied are mass flux (450–935 kg/m 2 s) and inlet subcooling (29 °C, 50 °C and 70 °C). Infra-red thermography is used for the measurement of local wall temperature to estimate the heat transfer coefficient in single phase and two phase flows with water as the working medium at atmospheric pressure. Correlation for single phase diabatic pressure drop ratio (diabatic to adiabatic) as a function of viscosity ratio (wall temperature to fluid temperature) is presented. Correlation for pressure drop under subcooled boiling conditions as a function of Boiling number (Bo) and Jakob number (Ja) is obtained. Correlation for single phase heat transfer coefficient in the thermal developing region is presented as a function of Reynolds number (Re), Prandtl number (Pr) and z/d (ratio of axial length of the test section to diameter). Correlation for two phase heat transfer coefficient under subcooled boiling condition is developed as a function of boiling number (Bo), Jakob number (Ja) and Prandtl number (Pr)

  5. The turbulent mean-velocity profile: it is all in the spectrum

    Science.gov (United States)

    Gioia, Gustavo; Guttenberg, Nicholas; Goldenfeld, Nigel; Chakraborty, Pinaki

    2010-11-01

    It has long been surmised that the mean-velocity profile (MVP) of a pipe flow is closely related to the spectrum of turbulent energy. Here we perform a spectral analysis to identify the eddies that dominate the production of shear stress via momentum transfer. This analysis allows us to express the MVP as a functional of the spectrum. Each part of the MVP relates to a specific spectral range: the buffer layer to the dissipative range, the log layer to the inertial range, and the wake to the energetic range. The parameters of the spectrum set the thickness of the viscous layer, the amplitude of the buffer layer, and the amplitude of the wake.

  6. The x-ray spectrum of the Cygnus Loop measured with Gas Scintillation Proportional Counters

    International Nuclear Information System (INIS)

    Tsunemi, Hiroshi; Manabe, Makoto; Yamashita, Koujun; Koyama, Katsuji.

    1988-01-01

    We report the results of an observation of the whole Cygnus Loop performed with the Gas Scintillation Proportional Counters (GSPC) on board the Tenma satellite. Line emissions around 1.9 keV and 2.5 keV, probably originating from silicon and sulfur Kα line blends, were detected. The continuum spectrum in the energy range 1-3 keV can be represented by a thermal bremsstrahlung spectrum with a temperature of 7 x 10 6 K. This is the highest value for the Cygnus Loop reported so far. The Tenma data were also combined with those from a sounding rocket flight performed previously, in which a similar detector system was employed. Thus, we obtain a wide-band X-ray spectrum for the whole Cygnus Loop with the best energy resolution reported so far. The combined data could not be fitted by a single temperature component in the thermal collisional ionization equilibrium (CIE) model or a single-temperature nonequilibrium ionization (NEI) model. A good fit is obtained if at least two temperature components are included in both the CIE and NEI models. However, only the NEI model allows a self consistent interpretation. Taking into account the emission measures for both components, we can conclude that the low-temperature, high-density component arises mainly from the shell region and that the high-temperature, low-density component arises from the interior of the shell. (author)

  7. An Effective Experimental Optimization Method for Wireless Power Transfer System Design Using Frequency Domain Measurement

    Directory of Open Access Journals (Sweden)

    Sangyeong Jeong

    2017-10-01

    Full Text Available This paper proposes an experimental optimization method for a wireless power transfer (WPT system. The power transfer characteristics of a WPT system with arbitrary loads and various types of coupling and compensation networks can be extracted by frequency domain measurements. The various performance parameters of the WPT system, such as input real/imaginary/apparent power, power factor, efficiency, output power and voltage gain, can be accurately extracted in a frequency domain by a single passive measurement. Subsequently, the design parameters can be efficiently tuned by separating the overall design steps into two parts. The extracted performance parameters of the WPT system were validated with time-domain experiments.

  8. Rethinking Functional Outcome Measures: The Development of a Novel Upper Limb Token Transfer Test to Assess Basal Ganglia Dysfunction

    Directory of Open Access Journals (Sweden)

    Susanne P. Clinch

    2018-05-01

    Full Text Available The basal ganglia are implicated in a wide range of motor, cognitive and behavioral activities required for normal function. This region is predominantly affected in Huntington's disease (HD, meaning that functional ability progressively worsens. However, functional outcome measures for HD, particularly those for the upper limb, are limited meaning there is an imperative for well-defined, quantitative measures. Here we describe the development and evaluation of the Moneybox test (MBT. This novel, functional upper limb assessment was developed in accordance with translational neuroscience and physiological principles for people with a broad disease manifestation, such as HD. Participants with HD (n = 64 and healthy controls (n = 21 performed the MBT, which required subjects to transfer tokens into a container in order of size (Baseline Transfer, value (Complex Transfer with and without reciting the alphabet (Dual Transfer. Disease specific measures of motor, cognition, behavior, and function were collected. HD patients were grouped into disease stage, from which, discriminative and convergent validity was assessed using Analysis of Variance and Pearson's correlation respectively. Manifest HD participants were slower than pre-manifest and control participants, and achieved significantly lower MBT total scores. Performance in the Complex Transfer and Dual Transfer tasks were significantly different between pre-manifest and stage 1 HD. All MBT performance variables significantly correlated with routinely used measures of motor, cognition, behavior, and function. The MBT provides a valid, sensitive, and affordable functional outcome measure. Unlike current assessments, MBT performance significantly distinguished the subtle differences between the earliest disease stages of HD, which are the populations typically targeted in clinical trials.

  9. Spectrum pooling in MnWave Networks

    DEFF Research Database (Denmark)

    Boccardi, Federico; Shokri-Ghadikolaei, Hossein; Fodor, Gabor

    2016-01-01

    Motivated by the specific characteristics of mmWave technologies, we discuss the possibility of an authorization regime that allows spectrum sharing between multiple operators, also referred to as spectrum pooling. In particular, considering user rate as the performance measure, we assess...

  10. Project Spectrum: An Innovative Assessment Alternative.

    Science.gov (United States)

    Krechevsky, Mara

    1991-01-01

    Project Spectrum attempts to reconceptualize the traditional linguistic and logical/mathematical bases of intelligence. Spectrum blurs the line between curriculum and assessment, embeds assessment in meaningful, real-world activities, uses "intelligence-fair" measures, emphasizes children's strengths, and recognizes the stylistic…

  11. Neutron spectrum unfolding: Pt. 2

    International Nuclear Information System (INIS)

    Matiullah; Wiyaja, D.S.; Berzonis, M.A.; Bondars, H.; Lapenas, A.A.; Kudo, K.; Majeed, A.; Durrani, S.A.

    1991-01-01

    In Part I of this paper, we described the use of the computer code SAIPS in neutron spectrum unfolding. Here in Part II, we present our experimental work carried out to study the shape of the neutron spectrum in different experimental channels of a 5 MW light-water cooled and moderated research reactor. The spectral neutron flux was determined using various fission foils (placed in close contact with mica track detectors) and activation detectors. From the measured activities, the neutron spectrum was unfolded by SAIPS. (author)

  12. Prediction of Support Reaction Forces of ITA via Response Spectrum Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Jin Sung; Jeong, Joon Ho; Lee, Sang Jin; Oh, Jin Ho; Lee, Jong Min [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The irradiation targets are transferred along pipes between TTS (Target Transfer Station) and ITA (Irradiation Tube Assembly) by hydraulic forces. The ITA corresponds to the vertical guide tube for irradiation targets inside a reactor, and it penetrates the reactor structure. Because the ITA is classified into seismic category II, its structural integrity must be evaluated by the seismic analysis. To approach more realistic problem, the interaction between the ITA and the reactor structure must be considered. However, this paper is focused on the preliminary analysis, and it is simplified that only the response of the ITA caused by earthquake affects the reactor structure. The response of the ITA is predicted by the spectrum response analysis based on the FDRS (Floor Design Response Spectra) of KJRR. Finally, the reaction forces corresponding to the load transfer into the reactor structure are estimated by using ANSYS. In this study, the reaction forces due to the earthquake are estimated by the response spectrum analysis. For the saving computational time and resource required, the FE model with beam element is constructed, and it is confirmed that the accuracy of the solution is acceptable by comparing the results of the solid model.

  13. a Middle-Ear Reverse Transfer Function Computed from Vibration Measurements of Otoacoustic Emissions on the Ear Drum of the Guinea PIG

    Science.gov (United States)

    Dalhoff, Ernst; Turcanu, Diana; Gummer, Anthony W.

    2009-02-01

    Using distortion products measured as vibration of the umbo and as sound pressure in the ear canal of guinea pigs, we calculated the corresponding reverse transfer function. We compare the measurements with a middle-ear model taken from the literature and adapted to the guinea pig. A reasonable fit could be achieved. We conclude that the reverse transfer function will be useful to aid fitting a middle-ear model to measured transfer functions of human subjects.

  14. The Cosmic Ray Energy Spectrum and Related Measurements with the Pierre Auger Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, : J.; Abreu, P.; Aglietta, M.; Aguirre, C.; Ahn, E.J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez-Muniz, J.; Ambrosio, M.; Anchordoqui, L.

    2009-06-01

    These are presentations to be presented at the 31st International Cosmic Ray Conference, in Lodz, Poland during July 2009. It consists of the following presentations: (1) Measurement of the cosmic ray energy spectrum above 10{sup 18} eV with the Pierre Auger Observatory; (2) The cosmic ray flux observed at zenith angles larger than 60 degrees with the Pierre Auger Observatory; (3) Energy calibration of data recorded with the surface detectors of the Pierre Auger Observatory; (4) Exposure of the Hybrid Detector of The Pierre Auger Observatory; and (5) Energy scale derived from Fluorescence Telescopes using Cherenkov Light and Shower Universality.

  15. New fission-neutron-spectrum representation for ENDF

    International Nuclear Information System (INIS)

    Madland, D.G.

    1982-04-01

    A new representation of the prompt fission neutron spectrum is proposed for use in the Evaluated Nuclear Data File (ENDF). The proposal is made because a new theory exists by which the spectrum can be accurately predicted as a function of the fissioning nucleus and its excitation energy. Thus, prompt fission neutron spectra can be calculated for cases where no measurements exist or where measurements are not possible. The mathematical formalism necessary for application of the new theory within ENDF is presented and discussed for neutron-induced fission and spontaneous fission. In the case of neutron-induced fission, expressions are given for the first-chance, second-chance, third-chance, and fourth-chance fission components of the spectrum together with that for the total spectrum. An ENDF format is proposed for the new fission spectrum representation, and an example of the use of the format is given

  16. Novel DNA sequence detection method based on fluorescence energy transfer

    International Nuclear Information System (INIS)

    Kobayashi, S.; Tamiya, E.; Karube, I.

    1987-01-01

    Recently the detection of specific DNA sequence, DNA analysis, has been becoming more important for diagnosis of viral genomes causing infections disease and human sequences related to inherited disorders. These methods typically involve electrophoresis, the immobilization of DNA on a solid support, hybridization to a complementary probe, the detection using labeled with /sup 32/P or nonisotopically with a biotin-avidin-enzyme system, and so on. These techniques are highly effective, but they are very time-consuming and expensive. A principle of fluorescene energy transfer is that the light energy from an excited donor (fluorophore) is transferred to an acceptor (fluorophore), if the acceptor exists in the vicinity of the donor and the excitation spectrum of donor overlaps the emission spectrum of acceptor. In this study, the fluorescence energy transfer was applied to the detection of specific DNA sequence using the hybridization method. The analyte, single-stranded DNA labeled with the donor fluorophore is hybridized to a probe DNA labeled with the acceptor. Because of the complementary DNA duplex formation, two fluorophores became to be closed to each other, and the fluorescence energy transfer was occurred

  17. Measurements of the absolute neutron fluence spectrum emitted at 00 and 900 from the Little-Boy replica

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; Preston, C.C.

    1986-01-01

    Nuclear research emulsions (NRE) have been used to characterize the neutron spectrum emitted by the Little-Boy replica. NRE were irradiated at the Little-Boy surface, as well as approximately 2 m from the center of the Little-Boy replica, using polar angles of 0 0 , 30 0 , 60 0 , and 90 0 . For the NRE exposed at 2 m, neutron background was determined using shadow shields of borated polyethylene. Emulsion scanning to date has concentrated exclusively on the 2-m, 0 0 and 2-m, 90 0 locations. Approximately 5000 proton-recoil tracks have been measured in NRE irradiated at each of these locations. At the 2-m, 90 0 location, the NRE neutron spectrum extends from 0.37 MeV up to 8.2 MeV; whereas the NRE neutron spectrum at the 2-m, 0 0 location is much softer and extends only up to 2.7 MeV. NRE neutron spectrometry results at these two locations are compared with both liquid scintillator neutron spectrometry and Monte Carlo calculations. (author)

  18. FOREGROUND CONTAMINATION IN INTERFEROMETRIC MEASUREMENTS OF THE REDSHIFTED 21 cm POWER SPECTRUM

    International Nuclear Information System (INIS)

    Bowman, Judd D.; Morales, Miguel F.; Hewitt, Jacqueline N.

    2009-01-01

    Subtraction of astrophysical foreground contamination from 'dirty' sky maps produced by simulated measurements of the Murchison Widefield Array (MWA) has been performed by fitting a third-order polynomial along the spectral dimension of each pixel in the data cubes. The simulations are the first to include the unavoidable instrumental effects of the frequency-dependent primary antenna beams and synthesized array beams. They recover the one-dimensional spherically binned input redshifted 21 cm power spectrum within ∼1% over the scales probed most sensitively by the MWA (0.01 ∼ -1 ) and demonstrate that realistic instrumental effects will not mask the epoch of reionization signal. We find that the weighting function used to produce the dirty sky maps from the gridded visibility measurements is important to the success of the technique. Uniform weighting of the visibility measurements produces the best results, whereas natural weighting significantly worsens the foreground subtraction by coupling structure in the density of the visibility measurements to spectral structure in the dirty sky map data cube. The extremely dense uv-coverage of the MWA was found to be advantageous for this technique and produced very good results on scales corresponding to |u| ∼< 500λ in the uv-plane without any selective editing of the uv-coverage.

  19. Comparison of holographic setups used in heat and mass transfer measurement

    Science.gov (United States)

    Doleček, R.; Psota, P.; Lédl, V.; Vít, T.; Kopecký, V.

    2014-03-01

    The authors of the paper deal with measurement of heat and mass transfer for several years and they have frequently used few techniqes for measurement of refractive index distribution based on holographic interferometry. Some of the well known techniques have been modified some and some new ones developped. Every technique could be applied with success in different type of meassurement and obviously every one has set of properties making them unique. We decided to digest few different basic techniques and describe its properties in this paper with the aim to help the reader select the proper one for their measurement. The list of techniques and its properties is not comprehensive but schould serve as a basic orientation in the field.

  20. Comparison of holographic setups used in heat and mass transfer measurement

    Directory of Open Access Journals (Sweden)

    Doleček R.

    2014-03-01

    Full Text Available The authors of the paper deal with measurement of heat and mass transfer for several years and they have frequently used few techniqes for measurement of refractive index distribution based on holographic interferometry. Some of the well known techniques have been modified some and some new ones developped. Every technique could be applied with success in different type of meassurement and obviously every one has set of properties making them unique. We decided to digest few different basic techniques and describe its properties in this paper with the aim to help the reader select the proper one for their measurement. The list of techniques and its properties is not comprehensive but schould serve as a basic orientation in the field.

  1. Measurement of vacancy transfer probability from K to L shell using ...

    Indian Academy of Sciences (India)

    73, No. 4. — journal of. October 2009 physics pp. 711–718. Measurement of vacancy transfer probability from K to L shell using K-shell fluorescence yields. ¨O S¨O˘GÜT1,∗, E BÜYÜKKASAP2, A KÜC¸ ÜK¨ONDER1 and T TARAKC¸ IO ˇGLU1. 1Department of Physics, Faculty of Science and Letters, Kahramanmaras Sütçü ˙ ...

  2. Experimental spectrum of reactor antineutrinos and spectra of main fissile isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Sinev, V. V., E-mail: vsinev@pcbai10.inr.ruhep.ru [Russian Academy of Sciences, Institute for Nuclear Research (Russian Federation)

    2013-05-15

    Within the period between the years 1988 and 1990, the spectrum of positrons from the inverse-beta-decay reaction on a proton was measured at the Rovno atomic power plant in the course of experiments conducted there. The measured spectrum has the vastest statistics in relation to other neutrino experiments at nuclear reactors and the lowest threshold for positron detection. An experimental reactor-antineutrino spectrum was obtained on the basis of this positron spectrum and was recommended as a reference spectrum. The spectra of individual fissile isotopes were singled out from the measured antineutrino spectrum. These spectra can be used to analyze neutrino experiments performed at nuclear reactors for various compositions of the fuel in the reactor core.

  3. Bayesian calibration of reactor neutron flux spectrum using activation detectors measurements: Application to CALIBAN reactor

    International Nuclear Information System (INIS)

    Cartier, J.; Casoli, P.; Chappert, F.

    2013-01-01

    In this paper, we present calibration methods in order to estimate reactor neutron flux spectrum and its uncertainties by using integral activation measurements. These techniques are performed using Bayesian and MCMC framework. These methods are applied to integral activation experiments in the cavity of the CALIBAN reactor. We estimate the neutron flux and its related uncertainties. The originality of this work is that these uncertainties take into account measurements uncertainties, cross-sections uncertainties and model error. In particular, our results give a very good approximation of the total flux and indicate that neutron flux from MCNP simulation for energies above about 5 MeV seems to overestimate the 'real flux'. (authors)

  4. Elaboration And Study Of Transfer Alanine/ESR Dosemeters

    International Nuclear Information System (INIS)

    Torres G, Luz A.

    1996-01-01

    The dosimetry is the dose measure imparted by the energy from the ionizing radiation to the matter. The dosemeters is the means used for the determination of such a dose. Diverse dosimetric classes exist, this classification depends in essence of the energy involved in the irradiation process and of its application necessity. It is as well as in radiological protection movie dosemeter is used, and TLD, in the calibration of units, as those of cobalt, the ionization cameras are used, in the detection of superficial contamination the accountants Geiger Muller and proportional etc. The transfer dosimeter Alanine/ESR is used, object of the present work, is characterized because after reading the registered dose, the information is conserved and it can be transferred and read in any team of ESR. Likewise the following dose that is imparted will be added to the previous one registered, this indicates that the dosemeters is of integral character. In the spectra taken ESR, it is determined that the integral double or area under the curve of the spectrum ESR is proportional to the concentration of free radicals generated by the radiation ionization and in turn this concentration is proportional to the dose received by the pills; in last, these proportionality relationships take to that the area under the curve of the spectrum main ESR is proportional to the radiation dose received by the alanine dosemeters. This dosemeter seeks to be an economic alternative that it will lend the calibration service that today offers the ionization Cameras or the acrylic red industrial dosemeters

  5. Web measurement - a tool to achieve reliable information on custody transfer measurement systems in pipeline operations; Web medicao - uma ferramenta de consolidacao de informacoes sobre sistemas de medicao para transferencia de custodia

    Energy Technology Data Exchange (ETDEWEB)

    Cid, Eliane Areas; Freitas, Surama de Oliveitra [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil). Centro de Pesquisas; Ferreira, Ana Luisa Auler da Silva; Dias, Gerson Vieira [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    The prompt and organized information about measurement systems is essential for custody transfer in the pipeline transportation business. This organized information can serve as a basis for operational, maintenance and commercial groups in pipeline transportation companies. This information can also help management in planning future improvements in hardware for custody transfer measurements. In nation-wide companies, like TRANSPETRO, information about custody transfer measurement systems, if not organized, will be scattered geographically and organizationally. In organizing this kind of information, distributed systems have a big advantage, with information maintained by operational groups and centralized in the headquarters of the company. This paper describes the implementation of a system for consolidating and updating company information about custody transfer measurement systems for liquid and gas. The system has been implemented on the Intranet, allowing initial data entry in a distributed way, and a centralized validation by the headquarters engineering group. The new methodology has sharply increased the reliability in the information of custody transfer measurement systems in the company. (author)

  6. Measurements of convective heat transfer to vertical upward flows of CO{sub 2} in circular tubes at near-critical and supercritical pressures

    Energy Technology Data Exchange (ETDEWEB)

    Zahlan, H., E-mail: hussamzahlan@gmail.com [Canadian Nuclear Laboratories, Chalk River, K0J 1J0 (Canada); Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5 (Canada); Groeneveld, D. [Canadian Nuclear Laboratories, Chalk River, K0J 1J0 (Canada); Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5 (Canada); Tavoularis, S. [Department of Mechanical Engineering, University of Ottawa, Ottawa, ON K1N 6N5 (Canada)

    2015-08-15

    Highlights: • We present and discuss results of thermal–hydraulic measurements in CO{sub 2} for the near critical and supercritical pressure region. • We report the full heat transfer and pressure drop database. - Abstract: An extensive experimental program of heat transfer measurements has been completed recently at the University of Ottawa's supercritical pressure test facility (SCUOL). Thermal–hydraulics tests were performed for vertical upflow of carbon dioxide in directly heated tubes with inner diameters of 8 and 22 mm, at high subcritical, near-critical and supercritical pressures. The test conditions, when converted to water-equivalent values, correspond to conditions of interest to current Super-Critical Water-Cooled Reactor designs, and include many measurements under conditions for which few data are available in the literature. These data significantly complement the existing experimental database and are being used for the derivation and validation of a new heat transfer prediction method in progress at the University of Ottawa. The same data are also suitable for the assessment of the accuracy of other heat transfer prediction methods and fluid-to-fluid scaling laws for near-critical and supercritical pressures. In addition, they permit further examination of previously suggested relationships describing the critical heat flux and post-dryout heat transfer coefficient at high subcritical pressures and the boundaries of the deteriorated/enhanced heat transfer regions for near-critical and supercritical pressures. The measurements reported in this paper cover several subcritical heat transfer modes, including single phase liquid heat transfer, nucleate boiling, critical heat flux, post-dryout heat transfer and superheated vapor heat transfer; they also cover several supercritical heat transfer modes, including heat transfer to liquid-like supercritical fluid and heat transfer to vapor-like supercritical fluid, which occurred in the

  7. Measurements for modeling radionuclide transfer in the aquatic environment

    International Nuclear Information System (INIS)

    Kahn, B.

    1976-01-01

    Analytical methods for measuring radionuclides in the aquatic environment are discussed for samples of fresh water and seawater, fish and shellfish, biota such as algae, plankton, seaweed, and aquatic plants, and sediment. Consideration is given to radionuclide collection and concentration, sample preservation, radiochemical and instrumental analysis, and quality assurance. Major problems are the very low environmental levels of the radionuclides of interest, simultaneous occurrence of radionuclides in several chemical and physical forms and the numerous factors that affect radionuclide levels in and transfers among media. Some radionuclides of importance in liquid effluents from nuclear power stations are listed, and sources of radiochemical analytical methods are recommended

  8. Measured elemental transfer factors for boreal hunter/gatherer scenarios: fish, game and berries

    International Nuclear Information System (INIS)

    Sheppard, S.C.; Long, J.M.; Sanipelli, B.

    2010-01-01

    The environmental assessment of long-term nuclear waste management requires data to estimate food chain transfers for radionuclides in various environmental settings. For key elements such as iodine (I) and chlorine (Cl), there is a paucity of transfer factor data, particularly outside of agricultural food chains. This study dealt with transfers of I, Cl and 28 other elements to foods that would be typical of boreal hunter/gatherer lifestyles, as well as being common foods for modern recreational and subsistence hunters. Food/substrate concentration ratios (CRs) and related transfer factors for eight species of widely distributed fish, whitetail deer (Odocoileus virginianus), Canada geese (Branta canadensis) and wild blueberries (Vaccinium myrtilloides) were measured and compared to the literature. Limited data were obtained for caribou (Rangifer tarandus), elk (Cervus elaphus) and moose (Alces americanus). Freshwater sediment Kd values and CRs for a ubiquitous freshwater macrophyte were also obtained. The CRs for I in fish were 29 L kg -1 in edible muscle (fillets) of large-bodied species and 85 L kg -1 for whole, small-bodied fish. The log CRs for fish and macrophytes were correlated across elements. For several elements, the Kds for sediments in deep water were ∼4-fold higher than for littoral samples. The elemental transfers to wild animals for some elements were notably different than the literature indicates for domestic animals. It is argued that the transfer data obtained using indigenous elements from real environmental settings, as opposed to contaminant elements in experimental or impacted environments, are especially relevant to assessment of long-term impacts.

  9. Measured elemental transfer factors for boreal hunter/gatherer scenarios: fish, game and berries

    Energy Technology Data Exchange (ETDEWEB)

    Sheppard, S.C., E-mail: sheppards@ecomatters.co [ECOMatters Inc., WB Lewis Business Centre, 24 Aberdeen Avenue, Pinawa, Manitoba R0E 1L0 (Canada); Long, J.M.; Sanipelli, B. [ECOMatters Inc., WB Lewis Business Centre, 24 Aberdeen Avenue, Pinawa, Manitoba R0E 1L0 (Canada)

    2010-11-15

    The environmental assessment of long-term nuclear waste management requires data to estimate food chain transfers for radionuclides in various environmental settings. For key elements such as iodine (I) and chlorine (Cl), there is a paucity of transfer factor data, particularly outside of agricultural food chains. This study dealt with transfers of I, Cl and 28 other elements to foods that would be typical of boreal hunter/gatherer lifestyles, as well as being common foods for modern recreational and subsistence hunters. Food/substrate concentration ratios (CRs) and related transfer factors for eight species of widely distributed fish, whitetail deer (Odocoileus virginianus), Canada geese (Branta canadensis) and wild blueberries (Vaccinium myrtilloides) were measured and compared to the literature. Limited data were obtained for caribou (Rangifer tarandus), elk (Cervus elaphus) and moose (Alces americanus). Freshwater sediment Kd values and CRs for a ubiquitous freshwater macrophyte were also obtained. The CRs for I in fish were 29 L kg{sup -1} in edible muscle (fillets) of large-bodied species and 85 L kg{sup -1} for whole, small-bodied fish. The log CRs for fish and macrophytes were correlated across elements. For several elements, the Kds for sediments in deep water were {approx}4-fold higher than for littoral samples. The elemental transfers to wild animals for some elements were notably different than the literature indicates for domestic animals. It is argued that the transfer data obtained using indigenous elements from real environmental settings, as opposed to contaminant elements in experimental or impacted environments, are especially relevant to assessment of long-term impacts.

  10. Heat and Mass Transfer Measurements for Tray-Fermented Fungal Products

    Science.gov (United States)

    Jou, R.-Y.; Lo, C.-T.

    2011-01-01

    In this study, heat and mass transfer in static tray fermentation, which is widely used in solid-state fermentation (SSF) to produce fungal products, such as enzymes or koji, is investigated. Specifically, kinetic models of transport phenomena in the whole-tray chamber are emphasized. The effects of temperature, moisture, and humidity on microbial growth in large-scale static tray fermentation are essential to scale-up SSF and achieve uniform fermentation. In addition, heat and mass transfer of static tray fermentation of Trichoderma fungi with two tray setups—traditional linen coverings and stacks in a temperature-humidity chamber is examined. In both these setups, the following factors of fermentation were measured: air velocity, air temperature, illumination, pH, carbon dioxide (CO2) concentration, and substrate temperature, and the effects of bed height, moisture of substrate, and relative humidity of air are studied. A thin (1 cm) bed at 28 °C and 95 % relative humidity is found to be optimum. Furthermore, mixing was essential for achieving uniform fermentation of Trichoderma fungi. This study has important applications in large-scale static tray fermentation of fungi.

  11. A New Digital Signal Processing Method for Spectrum Interference Monitoring

    Science.gov (United States)

    Angrisani, L.; Capriglione, D.; Ferrigno, L.; Miele, G.

    2011-01-01

    Frequency spectrum is a limited shared resource, nowadays interested by an ever growing number of different applications. Generally, the companies providing such services pay to the governments the right of using a limited portion of the spectrum, consequently they would be assured that the licensed radio spectrum resource is not interested by significant external interferences. At the same time, they have to guarantee that their devices make an efficient use of the spectrum and meet the electromagnetic compatibility regulations. Therefore the competent authorities are called to control the access to the spectrum adopting suitable management and monitoring policies, as well as the manufacturers have to periodically verify the correct working of their apparatuses. Several measurement solutions are present on the market. They generally refer to real-time spectrum analyzers and measurement receivers. Both of them are characterized by good metrological accuracies but show costs, dimensions and weights that make no possible a use "on the field". The paper presents a first step in realizing a digital signal processing based measurement instrument able to suitably accomplish for the above mentioned needs. In particular the attention has been given to the DSP based measurement section of the instrument. To these aims an innovative measurement method for spectrum monitoring and management is proposed in this paper. It performs an efficient sequential analysis based on a sample by sample digital processing. Three main issues are in particular pursued: (i) measurement performance comparable to that exhibited by other methods proposed in literature; (ii) fast measurement time, (iii) easy implementation on cost-effective measurement hardware.

  12. Suppression of narrow-band interference in a PN spread-spectrum receiver using a CTD-based adaptive filter

    Science.gov (United States)

    Saulnier, G. J.; Das, P.; Milstein, L. B.

    1984-11-01

    Analytical results have shown that adaptive filtering can be a powerful tool for the rejection of narrow-band interference in a spread-spectrum receiver. However, the complexity of adaptive filtering hardware has hindered the experimental verification of these results. This paper describes a new adaptive filter architecture for implementing the Widrow-Hoff LMS algorithm while using only two multipliers regardless of filter order. This hardware simplification is achieved through the use of a burst processing technique. A 16-tap version of this adaptive filter constructed using charge-transfer devices (CTD's) is used to suppress a single tone jammer in a direct sequence spread-spectrum receiver. Probability of error measurements demonstrating the effectiveness of the adaptive filter for suppressing the single tone jammer along with simulation results for the optimal Weiner-Hopf filter are presented and discussed.

  13. Complexity measures of music

    Science.gov (United States)

    Pease, April; Mahmoodi, Korosh; West, Bruce J.

    2018-03-01

    We present a technique to search for the presence of crucial events in music, based on the analysis of the music volume. Earlier work on this issue was based on the assumption that crucial events correspond to the change of music notes, with the interesting result that the complexity index of the crucial events is mu ~ 2, which is the same inverse power-law index of the dynamics of the brain. The search technique analyzes music volume and confirms the results of the earlier work, thereby contributing to the explanation as to why the brain is sensitive to music, through the phenomenon of complexity matching. Complexity matching has recently been interpreted as the transfer of multifractality from one complex network to another. For this reason we also examine the mulifractality of music, with the observation that the multifractal spectrum of a computer performance is significantly narrower than the multifractal spectrum of a human performance of the same musical score. We conjecture that although crucial events are demonstrably important for information transmission, they alone are not suficient to define musicality, which is more adequately measured by the multifractality spectrum.

  14. Contrast computation methods for interferometric measurement of sensor modulation transfer function

    Science.gov (United States)

    Battula, Tharun; Georgiev, Todor; Gille, Jennifer; Goma, Sergio

    2018-01-01

    Accurate measurement of image-sensor frequency response over a wide range of spatial frequencies is very important for analyzing pixel array characteristics, such as modulation transfer function (MTF), crosstalk, and active pixel shape. Such analysis is especially significant in computational photography for the purposes of deconvolution, multi-image superresolution, and improved light-field capture. We use a lensless interferometric setup that produces high-quality fringes for measuring MTF over a wide range of frequencies (here, 37 to 434 line pairs per mm). We discuss the theoretical framework, involving Michelson and Fourier contrast measurement of the MTF, addressing phase alignment problems using a moiré pattern. We solidify the definition of Fourier contrast mathematically and compare it to Michelson contrast. Our interferometric measurement method shows high detail in the MTF, especially at high frequencies (above Nyquist frequency). We are able to estimate active pixel size and pixel pitch from measurements. We compare both simulation and experimental MTF results to a lens-free slanted-edge implementation using commercial software.

  15. Cross Section Measurements for Some Elements Suited as Thermal Spectrum indicators: Cd, Sm, Gd and Lu

    Energy Technology Data Exchange (ETDEWEB)

    Sokolowski, E.; Pekarek, H.; Jonsson, E.

    1964-05-15

    The effective cross sections of Cd, Sm, Gd and Lu have been measured by the oscillator technique in the spectrum of the central channel of the Swedish reactor R1. For Cd, Sm and Gd the 2200 m/s cross sections were deduced on the basis of Westcott's g and s factors. The values obtained were generally in agreement with other recent values obtained by integral methods, although a systematic trend indicated that the value T{sub n} - T{sub m} = 29 {+-} 10 deg C for the neutron spectrum, measured with a fast chopper, was slightly too high. A new value of T{sub n} - T{sub m} = 22.5 {+-} 3.5 deg C was deduced and new 2200 m/s cross sections were obtained by iteration. For natural Lu, the energy dependence of the cross section is not well known. Certain assumptions about the cross section function led to unreasonably high values for the 2200 m/s cross section. Complementary differential measurements of the cross sections of Cd, Sm and Gd were made with the Rl fast chopper. For Cd and Sm the 2200 m/s cross section thus obtained agreed within experimental error with those obtained from the integral measurements. For Gd, the chopper measured value was higher, confirming earlier findings and indicating that the Westcott g factor for Gd is too high. Cd: Integral meas. : {sigma}(2200) = 2,390 {+-} 45 b; Differential meas. : {sigma}(2200) = 2,445 {+-} 25 b; Sm: Integral meas. : {sigma}(2200) = 5,880 {+-} 90 b; Differential meas. : {sigma}(2200) = 5,740 {+-} 150 b; Gd: Integral meas. : {sigma}(2200) = 46,470 {+-} 550 b; Differential meas. : {sigma}(2200) = 47,900 {+-} 700 b.

  16. Cross Section Measurements for Some Elements Suited as Thermal Spectrum indicators: Cd, Sm, Gd and Lu

    Energy Technology Data Exchange (ETDEWEB)

    Sokolowski, E; Pekarek, H; Jonsson, E

    1964-05-15

    The effective cross sections of Cd, Sm, Gd and Lu have been measured by the oscillator technique in the spectrum of the central channel of the Swedish reactor R1. For Cd, Sm and Gd the 2200 m/s cross sections were deduced on the basis of Westcott's g and s factors. The values obtained were generally in agreement with other recent values obtained by integral methods, although a systematic trend indicated that the value T{sub n} - T{sub m} = 29 {+-} 10 deg C for the neutron spectrum, measured with a fast chopper, was slightly too high. A new value of T{sub n} - T{sub m} = 22.5 {+-} 3.5 deg C was deduced and new 2200 m/s cross sections were obtained by iteration. For natural Lu, the energy dependence of the cross section is not well known. Certain assumptions about the cross section function led to unreasonably high values for the 2200 m/s cross section. Complementary differential measurements of the cross sections of Cd, Sm and Gd were made with the Rl fast chopper. For Cd and Sm the 2200 m/s cross section thus obtained agreed within experimental error with those obtained from the integral measurements. For Gd, the chopper measured value was higher, confirming earlier findings and indicating that the Westcott g factor for Gd is too high. Cd: Integral meas. : {sigma}(2200) = 2,390 {+-} 45 b; Differential meas. : {sigma}(2200) = 2,445 {+-} 25 b; Sm: Integral meas. : {sigma}(2200) = 5,880 {+-} 90 b; Differential meas. : {sigma}(2200) = 5,740 {+-} 150 b; Gd: Integral meas. : {sigma}(2200) = 46,470 {+-} 550 b; Differential meas. : {sigma}(2200) = 47,900 {+-} 700 b.

  17. Measurement of the fuel temperature and the fuel-to-coolant heat transfer coefficient of Super Phenix 1 fuel elements

    International Nuclear Information System (INIS)

    Edelmann, M.

    1995-12-01

    A new measurement method for measuring the mean fuel temperature as well as the fuel-to-coolant heat transfer coefficient of fast breeder reactor subassemblies (SA) is reported. The method is based on the individual heat balance of fuel SA's after fast reactor shut-downs and uses only the plants normal SA outlet temperature and neutron power signals. The method was used successfully at the french breeder prototype Super Phenix 1. The mean SA fuel temperature as well as the heat transfer coefficient of all SPX SA's have been determined at power levels between 15 and 90% of nominal power and increasing fuel burn-up from 3 to 83 EFPD (Equivalent of Full Power-Days). The measurements also provided fuel and whole SA time constants. The estimated accuracy of measured fuel parameters is in the order of 10%. Fuel temperatures and SA outlet temperature transients were also calculated with the SPX1 systems code DYN2 for exactly the same fuel and reactor operating parameters as in the experiments. Measured fuel temperatures were higher than calculated ones in all cases. The difference between measured and calculated core mean values increases from 50 K at low power to 180 K at 90% n.p. This is about the double of the experimental error margins. Measured SA heat transfer coefficients are by nearly 20% lower than corresponding heat transfer parameters used in the calculations. Discrepancies found between measured and calculated results also indicate that either the transient heat transfer in the gap between fuel and cladding (gap conductance) might not be exactly reproduced in the computer code or that the gap in the fresh fuel was larger than assumed in the calculations. (orig.) [de

  18. Resist-based measurement of contrast transfer function in a 0.3-NA microfield optic

    International Nuclear Information System (INIS)

    Cain, Jason P.; Naulleau, Patrick; Spanos, Costas J.

    2005-01-01

    Although extreme ultraviolet (EUV) lithography offers the possibility of very high-resolution patterning, the projection optics must be of extremely high quality in order to meet this potential. One key metric of the projection optic quality is the contrast transfer function (CTF), which is a measure of the aerial image contrast as a function of pitch. A static microfield exposure tool based on the 0.3-NA MET optic and operating at a wavelength of 13.5 nm has been installed at the Advanced Light Source, a synchrotron facility at the Lawrence Berkeley National Laboratory. This tool provides a platform for a wide variety of research into EUV lithography. In this work we present resist-based measurements of the contrast transfer function for the MET optic. These measurements are based upon line/space patterns printed in several different EUV photoresists. The experimental results are compared with the CTF in aerial-image simulations using the aberrations measured in the projection optic using interferometry. In addition, the CTF measurements are conducted for both bright-field and dark-field mask patterns. Finally, the orientation dependence of the CTF is measured in order to evaluate the effect of non-rotationally symmetric lens aberrations. These measurements provide valuable information in interpreting the results of other experiments performed using the MET and similar systems

  19. Nuclear analysis software. Pt. 2: Gamma spectrum analysis, activity calculations and neutron activiation analysis (GANAAS)

    International Nuclear Information System (INIS)

    1991-01-01

    A spectrum acquired with a multichannel analyzer is usually stored with a suitable device (tape, cassette tape, diskette, hard disk). Every manufacturer of multichannel analyzers uses his own method for storage, and records the spectra in his own format. Furthermore, the formats to save the spectra evolve in time: the same manufacturer can have several formats for different generations of multichannel analyzers. A similar situation prevails with the spectrum analysis programmes. They require spectra in a particular format as the input to the analysis. Again, these input formats are many and differ from each other considerably. SPEDAC set of routines was developed to provide the spectroscopist with a tool for converting the spectral formats. They can read the spectra recorded in a number of formats used in different multichannel analyzers, to a number of analysis programmes. In fact, all the major formats are represented. Another serious problem for the user of a stand-alone multichannel analyzer is the transfer of spectra from the MCA to the computer. For several well known types of MCAs, the Version 5.0 of SPEDAC offers a set of routines for spectrum transfer, using the most simple methods of interfacing. All the transfer programmes described in this manual have been carefully tested with the corresponding stand-alone multichannel analyzers

  20. Heat transfer in Rockwool modelling and method of measurement. Modelling radiative heat transfer in fibrous materials

    Energy Technology Data Exchange (ETDEWEB)

    Dyrboel, Susanne

    1998-05-01

    Fibrous materials are some of the most widely used materials for thermal insulation. In this project the focus of interest has been on fibrous materials for building application. Interest in improving the thermal properties of insulation materials is increasing as legislation is being tightened to reduce the overall energy consumption. A knowledge of the individual heat transfer mechanisms - whereby heat is transferred within a particular material is an essential tool to improve continuously the thermal properties of the material. Heat is transferred in fibrous materials by four different transfer mechanisms: conduction through air, conduction through fibres, thermal radiation and convection. In a particular temperature range the conduction through air can be regarded as a constant, and conduction through fibres is an insignificant part of the total heat transfer. Radiation, however, constitutes 25-40% of the total heat transfer in light fibrous materials. In Denmark and a number of other countries convection in fibrous materials is considered as non-existent when calculating heat transmission as well as when designing building structures. Two heat transfer mechanisms have been the focus of the current project: radiation heat transfer and convection. The radiation analysis serves to develop a model that can be used in further work to gain a wider knowledge of the way in which the morphology of the fibrous material, i.e. fibre diameter distribution, fibre orientation distribution etc., influences the radiation heat transfer under different conditions. The convection investigation serves to examine whether considering convection as non-existent is a fair assumption to use in present and future building structures. The assumption applied in practically is that convection makes a notable difference only in very thick insulation, at external temperatures below -20 deg. C, and at very low densities. For lager thickness dimensions the resulting heat transfer through the

  1. The effects of titanium dioxide coatings on light-derived heating and transdermal heat transfer in bovine skin

    Science.gov (United States)

    Bartle, S. J.; Thomson, D. U.; Gehring, R.; van der Merwe, D.

    2017-11-01

    The effects of titanium dioxide coatings of bovine hides on light absorption and transdermal transfer of light-derived heat were investigated. Four hair-on rug hides from Holstein cattle were purchased. Twelve samples about 20 cm on a side were cut from each hide; nine from the black-colored areas, and three from the white areas. Samples were randomized and assigned to four coating treatments: (1) white hide with no coating (White), (2) black hide with no coating (Black), (3) black hide with 50% coating (Mid), and (4) black hide with 100% coating (High). Coatings were applied to the black hide samples using a hand sprayer. Lux measurements were taken using a modified lux meter at three light intensities generated with a broad spectrum, cold halogen light source. Reflectance over a wavelength range of 380 to 900 nm was measured using a spectroradiometer. The transdermal transfer of heat derived from absorbed light was measured by applying a broad spectrum, cold halogen light source to the stratum corneum (coated) side of the sample and recording the temperature of the dermis-side using a thermal camera for 10 min at 30-s intervals. At the high light level, the White, Black, Mid, and High coating treatments had different ( P 400 to 750 nm), Black hides reflected 10 to 15% of the light energy, hides with the Mid coating treatment reflected 35 to 40%, and hides with the High coating treatment reflected 70 to 80% of the light energy. The natural White hide samples reflected 60 to 80% of the light energy. The average maximum temperatures at the dermis-side of the hides due to transferred heat were 34.5, 70.1, 55.0, and 31.7, for the White, Black, Mid, and High treatments, respectively. Reflective coatings containing titanium dioxide on cattle hides were effective in reducing light energy absorption and reduced light-derived heat transfer from the skin surface to deeper skin layers.

  2. Nonlinear entropy transfer in ETG-TEM turbulence via TEM driven zonal flows

    International Nuclear Information System (INIS)

    Asahi, Yuuichi; Tsutsui, Hiroaki; Tsuji-Iio, Shunji; Ishizawa, Akihiro; Sugama, Hideo; Watanabe, Tomohiko

    2015-01-01

    Nonlinear interplay of the electron temperature gradient (ETG) modes and the trapped electron modes (TEMs) was investigated by means of gyrokinetic simulation. Focusing on the situation where both TEMs and ETG modes are linearly unstable, the effects of TEM-driven zonal flows on ETG turbulence were examined by means of entropy transfer analysis. In a statistically steady turbulence where the TEM driven zonal flows are dominant, it turned out that the zonal flows meditate the entropy transfer of the ETG modes from the low to high radial wavenumber regions. The successive entropy transfer broadens the potential fluctuation spectrum in the radial wavenumber direction. In contrast, in the situation where ETG modes are unstable but TEMs are stable, the pure ETG turbulence does not produce strong zonal flows, leading to a rather narrow spectrum in the radial wavenumber space and a higher transport level. (author)

  3. Search for new physics in a precise 20F beta spectrum shape measurement

    Science.gov (United States)

    George, Elizabeth; Voytas, Paul; Chuna, Thomas; Naviliat-Cuncic, Oscar; Gade, Alexandra; Hughes, Max; Huyan, Xueying; Liddick, Sean; Minamisono, Kei; Paulauskas, Stanley; Weisshaar, Dirk; Ban, Gilles; Flechard, Xavier; Lienard, Etienne

    2015-10-01

    We are carrying out a measurement of the shape of the energy spectrum of β particles from 20F decay. We aim to achieve a relative precision below 3%, representing an order of magnitude improvement compared to previous experiments. This level of precision will enable a test of the so-called strong form of the conserved vector current (CVC) hypothesis, and should also enable us to place competitive limits on the contributions of exotic tensor couplings in beta decay. In order to control systematic effects, we are using a technique that takes advantage of high energy radioactive beams at the NSCL to implant the decaying nuclei in a scintillation detector deep enough that the emitted beta particles cannot escape. The β-particle energy is measured with the implantation detector after switching off the beam implantation. Ancillary detectors are used to tag the 1.633-MeV γ-rays following the β decay for coincidence measurements in order to reduce backgrounds. We will give an overview and report on the status of the experiment.

  4. Measurement of characteristic to total spectrum ratio of tungsten X-ray spectra for the validation of the modified Tbc model

    International Nuclear Information System (INIS)

    Lopez G, A. H.; Costa, P. R.; Tomal, A.

    2014-08-01

    Primary X-ray spectra were measured in the range of 80 to 150 kV in order to validate a computer program based on a semiempirical model for X-ray spectra evaluation(tbc and mod). The ratio between the characteristic lines and total spectrum was considered for comparing the simulated results and experimental data. The raw spectra measured by the Cd Te detector were corrected by the detector efficiency, Compton effects and characteristic Cd and Te X-rays escape peaks, using a software specifically developed. The software Origin 8.5.1 was used to calculate the spectra and characteristic peaks areas. The obtained result shows that the experimental spectra have higher effective energy than the simulated spectra computed with tbc and mod software. The behavior of the ratio between the characteristic lines and total spectrum for simulated data presents discrepancy with the experimental result. Computed results are in good agreement with theoretical data published by Green, for spectra obtained with 3.04 mm of additional aluminum filtration. The difference of characteristic to total spectrum ratio between experimental and simulated data increases with the tube voltage. (Author)

  5. Measurement of characteristic to total spectrum ratio of tungsten X-ray spectra for the validation of the modified Tbc model

    Energy Technology Data Exchange (ETDEWEB)

    Lopez G, A. H.; Costa, P. R. [University of Sao Paulo, Institute of Physics, Laboratory of Radiation Dosimetry and Medical Physics, Matao Street, alley R, 187, 66318 Sao Paulo (Brazil); Tomal, A., E-mail: ahlopezg@usp.br [Universidade Federal de Goias, Physics Institute, Campus Samambaia, 131 Goiania, Goias (Brazil)

    2014-08-15

    Primary X-ray spectra were measured in the range of 80 to 150 kV in order to validate a computer program based on a semiempirical model for X-ray spectra evaluation(tbc and mod). The ratio between the characteristic lines and total spectrum was considered for comparing the simulated results and experimental data. The raw spectra measured by the Cd Te detector were corrected by the detector efficiency, Compton effects and characteristic Cd and Te X-rays escape peaks, using a software specifically developed. The software Origin 8.5.1 was used to calculate the spectra and characteristic peaks areas. The obtained result shows that the experimental spectra have higher effective energy than the simulated spectra computed with tbc and mod software. The behavior of the ratio between the characteristic lines and total spectrum for simulated data presents discrepancy with the experimental result. Computed results are in good agreement with theoretical data published by Green, for spectra obtained with 3.04 mm of additional aluminum filtration. The difference of characteristic to total spectrum ratio between experimental and simulated data increases with the tube voltage. (Author)

  6. Measurements of europium-152 depth profile of stone embankments exposed the Nagasaki atomic bomb for neutron spectrum analysis

    International Nuclear Information System (INIS)

    Tatsumi-Miyajima, Junko; Shimasaki, Tatsuya; Okajima, Shunzo; Takada, Jitsuya; Yoshida, Masahiro; Takao, Hideaki; Okumura, Yutaka; Nakazawa, Masaharu.

    1990-01-01

    Quantitative measurement of neutron-induced radionuclide of 152 Eu in rocks near the hypocenter (ground center of the atomic bomb explosion) in Nagasaki was performed to obtain the depth profiles and calculate the neutron energy spectrum. Core samples were drilled and taken from the stone embankments on both sides of river within a radius of 500 m from the hypocenter. After cutting each core into about 27 mm-thick sections, each section was measured its gamma-ray spectrum with a pure germanium semiconductor detector and analyzed a content of natural europium by the activation method. The highest value 8.0 x 10 -2 Bq/μg of 152 Eu at the time of the blast was obtained from the surface plates of rock cores collected near the hypocenter. The surface activity of cores was reduced with increasing the slant distances from the hypocenter. The slopes of the depth profiles were similar among samples taken from the same location. In order to analyze the depth profile of 152 Eu activity in rock andesite, experiments using a fast neutron reactor and thermal neutron reactor were carried out. Comparing the measurements on the A-bomb exposure rock with the simulated results at the reactors, among the experiments, the depth profile using the neutron moderator of 10 mm polyethylene was closed to that obtained from the A-bomb exposed samples. The experiment of thermal neutron incidence only could not reproduce the profiles from the A-bomb exposed samples. This fact indicates that the depth profiles of 152 Eu in rock exposed to the A-bomb include valuable information concerning the neutron spectrum and intensity. (author)

  7. Validation of the force and frequency characteristics of the activator adjusting instrument: effectiveness as a mechanical impedance measurement tool.

    Science.gov (United States)

    Keller, T S; Colloca, C J; Fuhr, A W

    1999-02-01

    To determine the dynamic force-time and force-frequency characteristics of the Activator Adjusting Instrument and to validate its effectiveness as a mechanical impedance measurement device; in addition, to refine or optimize the force-frequency characteristics of the Activator Adjusting Instrument to provide enhanced dynamic structural measurement reliability and accuracy. An idealized test structure consisting of a rectangular steel beam with a static stiffness similar to that of the human thoracolumbar spine was used for validation of a method to determine the dynamic mechanical response of the spine. The Activator Adjusting Instrument equipped with a load cell and accelerometer was used to measure forces and accelerations during mechanical excitation of the steel beam. Driving point and transfer mechanical impedance and resonant frequency of the beam were determined by use of a frequency spectrum analysis for different force settings, stylus masses, and stylus tips. Results were compared with beam theory and transfer impedance measurements obtained by use of a commercial electronic PCB impact hammer. The Activator Adjusting Instrument imparted a very complex dynamic impact comprising an initial high force (116 to 140 N), short duration pulse (analysis of the Activator Adjusting Instrument impulse indicated that the Activator Adjusting Instrument has a variable force spectrum and delivers its peak energy at a frequency of 20 Hz. Added masses and different durometer stylus tips had very little influence on the Activator Adjusting Instrument force spectrum. The resonant frequency of the beam was accurately predicted by both the Activator Adjusting Instrument and electronic PCB impact hammer, but variations in the magnitude of the driving point impedance at the resonant frequency were high (67%) compared with the transfer impedance measurements obtained with the electronic PCB impact hammer, which had a more uniform force spectrum and was more repeatable (frequency

  8. PC based system for absolute neutron flux-spectrum measurements. Final report for the period 1 April 1994 - 15 December 1997

    International Nuclear Information System (INIS)

    Dobrea, D.

    1998-01-01

    When measuring absolute neutron flux-spectra, thin detector foils are irradiated in a neutron field. The absolute activity of isotopes generated by activation or fission reactions (fission products) is then measured, using an efficiency calibrated high resolution gamma-ray spectroscopy system, and the absolute reaction rates for their production is determined. Finally the flux-spectrum is determined based upon the reaction rate values. A general method to obtain flux-spectra from the reaction rate is the unfolding method. The above process involves computations of photopeak area, reaction rate, flux perturbation corrections and flux-spectrum. The PC's are well suited for the data processing system outlined above. Using available interfaces, the PC's can be involved even in the data acquisition. Graphical facilities allow decision upon the data processing flow

  9. Measuring The Impact Of Cash Transfers And Behavioral 'Nudges' On Maternity Care In Nairobi, Kenya.

    Science.gov (United States)

    Cohen, Jessica; Rothschild, Claire; Golub, Ginger; Omondi, George N; Kruk, Margaret E; McConnell, Margaret

    2017-11-01

    Many patients in low-income countries express preferences for high-quality health care but often end up with low-quality providers. We conducted a randomized controlled trial with pregnant women in Nairobi, Kenya, to analyze whether cash transfers, enhanced with behavioral "nudges," can help women deliver in facilities that are consistent with their preferences and are of higher quality. We tested two interventions. The first was a labeled cash transfer (LCT), which explained that the cash was to help women deliver where they wanted. The second was a cash transfer that combined labeling and a commitment by the recipient to deliver in a prespecified desired facility as a condition of receiving the final payment (L-CCT). The L-CCT improved patient-perceived quality of interpersonal care but not perceived technical quality of care. It also increased women's likelihood of delivering in facilities that met standards for routine and emergency newborn care but not the likelihood of delivering in facilities that met standards for obstetric care. The LCT had fewer measured benefits. Women preferred facilities with high technical and interpersonal care quality, but these quality measures were often negatively correlated within facilities. Even with cash transfers, many women still used poor-quality facilities. A larger study is warranted to determine whether the L-CCT can improve maternal and newborn outcomes.

  10. Prompt neutron spectrum of the spontaneous fission of californium-252

    International Nuclear Information System (INIS)

    Zamyatnin, Yu.S.; Kroshkin, N.I.; Korostylev, V.A.; Nefedov, V.N.; Ryazanov, D.K.; Starostov, B.I.; Semenov, A.F.

    1976-01-01

    The californium-252 spontaneous fission neutron spectrum was measured in the energy range of 0.01 to 10 MeV by the time-of-flight technique using various neutron detectors. The measurements of 252 Cf neutron spectrum at energies of 0.01 to 5 MeV were performed as a function of fission fragment kinetic energy. The mean neutron spectrum energy in the range of 0.7 to 10 MeV was found from the results of measurements. The irregularity in the 252 Cf neutron spectrum in the neutron energy range of less than 0.7 MeV compared to theoretical values is discussed. The mechanism of 252 Cf neutron emission is also discussed on the basis of neutron yield angle measurements. 12 references

  11. Wavelength selection for portable noninvasive blood component measurement system based on spectral difference coefficient and dynamic spectrum

    Science.gov (United States)

    Feng, Ximeng; Li, Gang; Yu, Haixia; Wang, Shaohui; Yi, Xiaoqing; Lin, Ling

    2018-03-01

    Noninvasive blood component analysis by spectroscopy has been a hotspot in biomedical engineering in recent years. Dynamic spectrum provides an excellent idea for noninvasive blood component measurement, but studies have been limited to the application of broadband light sources and high-resolution spectroscopy instruments. In order to remove redundant information, a more effective wavelength selection method has been presented in this paper. In contrast to many common wavelength selection methods, this method is based on sensing mechanism which has a clear mechanism and can effectively avoid the noise from acquisition system. The spectral difference coefficient was theoretically proved to have a guiding significance for wavelength selection. After theoretical analysis, the multi-band spectral difference coefficient-wavelength selection method combining with the dynamic spectrum was proposed. An experimental analysis based on clinical trial data from 200 volunteers has been conducted to illustrate the effectiveness of this method. The extreme learning machine was used to develop the calibration models between the dynamic spectrum data and hemoglobin concentration. The experiment result shows that the prediction precision of hemoglobin concentration using multi-band spectral difference coefficient-wavelength selection method is higher compared with other methods.

  12. A quantitative study of valence electron transfer in the skutterudite compound CoP3 by combining x-ray induced Auger and photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Diplas, S; Prytz, Oe; Karlsen, O B; Watts, J F; Taftoe, J

    2007-01-01

    We use the sum of the ionization and Auger energy, the so-called Auger parameter, measured from the x-ray photoelectron spectrum, to study the valence electron distribution in the skutterudite CoP 3 . The electron transfer between Co and P was estimated using models relating changes in Auger parameter values to charge transfer. It was found that each P atom gains 0.24 e - , and considering the unit formula CoP 3 this is equivalent to a donation of 0.72 e - per Co atom. This is in agreement with a recent electron energy-loss spectroscopy study, which indicates a charge transfer of 0.77 e - /atom from Co to P

  13. Bayesian calibration of reactor neutron flux spectrum using activation detectors measurements: Application to CALIBAN reactor

    Energy Technology Data Exchange (ETDEWEB)

    Cartier, J. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, DIF, F-91297 Arpajon (France); Casoli, P. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, Valduc, F-21120 Is sur Tille (France); Chappert, F. [Commissariat a l' Energie Atomique et aux Energies Alternatives CEA, DAM, DIF, F-91297 Arpajon (France)

    2013-07-01

    In this paper, we present calibration methods in order to estimate reactor neutron flux spectrum and its uncertainties by using integral activation measurements. These techniques are performed using Bayesian and MCMC framework. These methods are applied to integral activation experiments in the cavity of the CALIBAN reactor. We estimate the neutron flux and its related uncertainties. The originality of this work is that these uncertainties take into account measurements uncertainties, cross-sections uncertainties and model error. In particular, our results give a very good approximation of the total flux and indicate that neutron flux from MCNP simulation for energies above about 5 MeV seems to overestimate the 'real flux'. (authors)

  14. Derivation of muon range spectrum under rock from the recent primary spectrum

    International Nuclear Information System (INIS)

    Pal, P.; Bhattacharyya, D.P.

    1985-01-01

    The muon range spectra under Mont Blanc Tunnel and Kolar Gold Field rocks have been calculated from the recently measured primary cosmic ray spectrum. The scaling hypothesis of Feynman has been used for the calculation of pion and kaon spectra in the atmosphere. The meson atmospheric diffusion equation has been solved by following the method of Bugaev et al. The derived muon energy spectrum has been found to be in good agreement with the measured data of the Kiel, Durham, DEIS, and Moscow University groups. The calculated muon energy spectra at large polar angles have been compared with the different experimental results. The integral muon spectrum up to 20 TeV supports the MARS burst data favourably. Using the procedure of Kobayakawa, the muon energy loss in rock due to ionization, pair production, and bremsstrahlung and nuclear interactions from Bezrukov and Bugaev, we have constructed the range-energy relation in Mont Blanc and Kolar Gold Field rocks. The estimated range spectra have been corrected for range fluctuations and have been compared with the Mont Blanc Tunnel data of Castagnoli et al., Bergamasco et al., and Sheldon et al. and the Kolar Gold Field data compilation by Krishnaswamy et al

  15. Computation, measurement and analysis of the reactivity-to-power-transfer-function for the sodium cooled nuclear power plant KNK I

    International Nuclear Information System (INIS)

    Hoppe, P.; Mitzel, F.

    1977-02-01

    The Reactivity-to-Power-Transfer-Function for the sodium cooled nuclear power plant KNK I (Kompakte Natriumgekuehlte Kernenergieanlage) has been measured and compared with theoretical results. The measurements have been performed with the help of pseudostochastic reactivity perturbations. The transfer function has been determined by computing the auto- and cross-power-spectral-densities for the reactivity- and neutron flux signals. The agreement between the experimental and theoretical transfer function could be improved by adjusting the reactivity coefficients. The applications of these measurements with respect to reactor diagnosis and malfunction detection are discussed. For this purpose the accuracy of the measured transfer function is of great importance. Therefore an extensive error analysis has been performed. It turned out, that the inherent instability of the reactor without control system and the feedback by the primary coolant system were the reasons for comparatively big systematical errors. The conditions have been derived under which these types of errors can be considerably reduced. The conclusions can also be applied to analogical measurements at fast sodium cooled reactors. Because of their inherent stability the systematical errors will be reduced. (orig.) [de

  16. Electromagnetically induced absorption due to transfer of coherence and to transfer of population

    International Nuclear Information System (INIS)

    Goren, C.; Rosenbluh, M.; Wilson-Gordon, A.D.; Friedmann, H.

    2003-01-01

    The absorption spectrum of a weak probe, interacting with a driven degenerate two-level atomic system, whose ground and excited hyperfine states are F g,e , can exhibit narrow peaks at line center. When the pump and probe polarizations are different, F e =F g +1 and F g >0, the electromagnetically induced absorption (EIA) peak has been shown to be due to the transfer of coherence (TOC) between the excited and ground states via spontaneous decay. We give a detailed explanation of why the TOC that leads to EIA (EIA-TOC) can only take place when ground-state population trapping does not occur, that is, when F e =F g +1. We also explain why EIA-TOC is observed in open systems. We show that EIA can also occur when the pump and probe polarizations are identical and F e =F g +1. This EIA is analogous to an effect that occurs in simple two-level systems when the collisional transfer of population (TOP) from the ground state to a reservoir is greater than that from the excited state. For a degenerate two-level system, the reservoir consists of the Zeeman sublevels of the ground hyperfine state, and of other nearby hyperfine states that do not interact with the pump. We will also discuss the four-wave mixing spectrum under the conditions where EIA-TOC and EIA-TOP occur

  17. Small thermistors for the measurement of heat transfer coefficients; Kleine Thermistoren zur Messung von Waermeuebergangskoeffizienten

    Energy Technology Data Exchange (ETDEWEB)

    Uffrecht, Wieland; Guenther, Andre [TU Dresden (Germany). Inst. fuer Stroemungsmechanik; Caspary, Volker [MAN Diesel und Turbo SE, Oberhausen (Germany)

    2012-07-01

    The measurement of heat transfer coefficients at rotating machine parts is a difficult measurement task and is particularily challenging for fast rotating parts with good thermal conductivity in combination with gaseous flow. This contribution reports about the test of a setup with small thermistors employed to achieve compatibility with the demands of telemetry. (orig.)

  18. Effect of relaxation and decay of a charge transfer shakeup satellite on Auger-electron spectroscopy spectra and Auger-photoelectron coincidence spectroscopy spectra of adsorbates

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2008-01-01

    An electron excited to an unoccupied part of adsorbate-substrate hybrid states in a chemisorbed molecule by a resonant core electron excitation or charge transfer (CT) shakeup may delocalize on time scale of core-hole decay so that the excited core-hole state relaxes partly or completely to a fully relaxed one. The Auger decay of the fully relaxed core-hole state via the relaxation of the excited one introduces an additional feature in the resonant Auger-electron spectroscopy (RAES) spectrum and the AES spectrum. However, the additional feature in the RAES spectrum is a normal AES spectrum by decay of the fully relaxed core-hole state, whereas the one in the AES spectrum is the AES spectrum by decay of the fully relaxed core-hole state broadened by the photoelectron spectroscopy (PES) CT shakeup satellite weighted by the branching ratio of the relaxation width. The discrepancies between the AES spectrum measured at high above the ionization threshold and the additional feature in the RAES spectrum consist of the symmetric-like part by the decay of the fully relaxed core-hole state via the relaxation of the CT shakeup state and the asymmetric part by the direct decay of the shakeup states. The asymmetric part increases with a decrease in the hybridization strength. This explains the variation with the hybridization strength in the discrepancies between the RAES spectra and the AES spectra of chemisorbed molecules such as CO/Ni, CO/Cu and CO/Ag. A comparison of the singles PES spectrum with the one measured in coincidence with the AES main line of a selected kinetic energy (KE) provides the delocalization rate of the excited electron in the CT shakeup state as a function of photoelectron KE. The coincidence measurement to obtain the partial singles PES spectrum is discussed

  19. Large IncHI2-plasmids encode extended-spectrum β-lactamases (ESBLs) in Enterobacter spp. bloodstream isolates, and support ESBL-transfer to Escherichia coli.

    Science.gov (United States)

    Nilsen, E; Haldorsen, B C; Sundsfjord, A; Simonsen, G S; Ingebretsen, A; Naseer, U; Samuelsen, O

    2013-11-01

    We investigated the prevalence of extended-spectrum β-lactamases (ESBLs) in Enterobacter spp. bloodstream isolates from 19 hospital laboratories in Norway during 2011. A total of 62/230 (27%) isolates were resistant to third-generation cephalosporins and four (1.7%) were ESBL-positive; blaCTX -M-15 (n = 3) and blaSHV -12 (n = 1). This is comparable to the prevalence of ESBLs in clinical isolates of Escherichia coli and Klebsiella pneumoniae in Norway during the same period. All ESBL-positive isolates were multidrug resistant (MDR) and harboured plasmid-mediated quinolone resistance. Three isolates supported transfer of large IncHI2-plasmids harbouring ESBL- and MDR-encoding genes to E. coli recipients by in vitro conjugation. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  20. Measurement of heat transfer effectiveness during collision of a Leidenfrost droplet with a heated wall - 15447

    International Nuclear Information System (INIS)

    Park, J.S.; Kim, H.; Bae, S.W.; Kim, K.D.

    2015-01-01

    Droplet-wall collision heat transfer during dispersed flow film boiling plays a role in predicting cooling rate and peak cladding temperature of overheated fuels during reflood following a LOCA accident in nuclear power plants. This study aims at experimentally studying effects of collision velocity and angle, as dynamic characteristics of the colliding droplet, on heat transfer. The experiments were performed by varying collision velocity from 0.2 to 1.5 m/s and collision angle between the droplet path and the wall in the range from 30 to 90 degrees under atmosphere condition. A single droplet was impinged on an infrared-opaque Pt film deposited on an infrared-transparent sapphire plate, which combination permits to measure temperature distribution of the collision surface using a high-speed infrared camera from below. The instantaneous local surface heat flux was obtained by solving transient heat conduction equation for the heated substrate using the measured surface temperature data as the boundary condition of the collision surface. Total heat transfer amount of a single droplet collision was calculated by integrating the local heat flux distribution on the effective heat transfer area during the collision time. The obtained results confirmed the finding from the previous studies that with increasing collision velocity, the heat transfer effectiveness increases due to the increase of the heat transfer area and the local heat flux value. Interestingly, it was found that as collision angle of a droplet with a constant collision velocity decreases from 90 to 50 degrees and thus the vertical velocity component of the collision decreases, the total heat transfer amount per a collision increases. It was observed that the droplet colliding with an angle less than 90 degrees slides on the surface during the collision and the resulting collision area is larger than that in the normal collision. On the other hand, further decrease of collision angle below 40 degrees

  1. 3D radiative transfer in stellar atmospheres

    International Nuclear Information System (INIS)

    Carlsson, M

    2008-01-01

    Three-dimensional (3D) radiative transfer in stellar atmospheres is reviewed with special emphasis on the atmospheres of cool stars and applications. A short review of methods in 3D radiative transfer shows that mature methods exist, both for taking into account radiation as an energy transport mechanism in 3D (magneto-) hydrodynamical simulations of stellar atmospheres and for the diagnostic problem of calculating the emergent spectrum in more detail from such models, both assuming local thermodynamic equilibrium (LTE) and in non-LTE. Such methods have been implemented in several codes, and examples of applications are given.

  2. Child Autism Spectrum Disorder Traits and Parenting Stress: The Utility of Using a Physiological Measure of Parental Stress

    Science.gov (United States)

    Factor, Reina S.; Swain, Deanna M.; Scarpa, Angela

    2018-01-01

    Caregivers of children with autism spectrum disorder (ASD) report greater stress due to unique parenting demands (e.g.; Estes et al. in "Brain Dev" 35(2):133-138, 2013). Stress is often studied through self-report and has not been extensively studied using physiological measures. This study compared parenting stress in mothers of…

  3. Spectrum estimation method based on marginal spectrum

    International Nuclear Information System (INIS)

    Cai Jianhua; Hu Weiwen; Wang Xianchun

    2011-01-01

    FFT method can not meet the basic requirements of power spectrum for non-stationary signal and short signal. A new spectrum estimation method based on marginal spectrum from Hilbert-Huang transform (HHT) was proposed. The procession of obtaining marginal spectrum in HHT method was given and the linear property of marginal spectrum was demonstrated. Compared with the FFT method, the physical meaning and the frequency resolution of marginal spectrum were further analyzed. Then the Hilbert spectrum estimation algorithm was discussed in detail, and the simulation results were given at last. The theory and simulation shows that under the condition of short data signal and non-stationary signal, the frequency resolution and estimation precision of HHT method is better than that of FFT method. (authors)

  4. Measurement of the momentum transferred between contacting bodies during the LISA test-mass release phase—uncertainty estimation

    International Nuclear Information System (INIS)

    De Cecco, M; Bortoluzzi, D; Da Lio, M; Baglivo, L; Benedetti, M

    2009-01-01

    The requirements for the Laser Interferometer Space Antenna (LISA) test-mass (TM) release phase are analysed in view of the building up of a testing facility aimed at on-Earth qualification of the release mechanism. Accordingly, the release of the TM to free-fall must provide a linear momentum transferred to the TM not exceeding 10 −5 kg m s −1 . In order to test this requirement, a double pendulum system has been developed. The mock-ups of the TM and the release-dedicated plunger are brought into contact and then the latter is quickly retracted. During and after release, the TM motion is measured by a laser interferometer. The transferred momentum is estimated from the free oscillations following the plunger retraction by means of a Wiener–Kolmogorov optimal filter. This work is aimed at modelling the measurement chain, taking into account procedure, instruments, mechanisms and data elaboration in order to estimate the uncertainty associated with the transferred momentum measurement by means of Monte Carlo simulation

  5. Two-dimensional radiative transfer for the retrieval of limb emission measurements in the martian atmosphere

    Science.gov (United States)

    Kleinböhl, Armin; Friedson, A. James; Schofield, John T.

    2017-01-01

    The remote sounding of infrared emission from planetary atmospheres using limb-viewing geometry is a powerful technique for deriving vertical profiles of structure and composition on a global scale. Compared with nadir viewing, limb geometry provides enhanced vertical resolution and greater sensitivity to atmospheric constituents. However, standard limb profile retrieval techniques assume spherical symmetry and are vulnerable to biases produced by horizontal gradients in atmospheric parameters. We present a scheme for the correction of horizontal gradients in profile retrievals from limb observations of the martian atmosphere. It characterizes horizontal gradients in temperature, pressure, and aerosol extinction along the line-of-sight of a limb view through neighboring measurements, and represents these gradients by means of two-dimensional radiative transfer in the forward model of the retrieval. The scheme is applied to limb emission measurements from the Mars Climate Sounder instrument on Mars Reconnaissance Orbiter. Retrieval simulations using data from numerical models indicate that biases of up to 10 K in the winter polar region, obtained with standard retrievals using spherical symmetry, are reduced to about 2 K in most locations by the retrieval with two-dimensional radiative transfer. Retrievals from Mars atmospheric measurements suggest that the two-dimensional radiative transfer greatly reduces biases in temperature and aerosol opacity caused by observational geometry, predominantly in the polar winter regions.

  6. Excitation spectrum and staggering transformations in lattice quantum models.

    Science.gov (United States)

    Faria da Veiga, Paulo A; O'Carroll, Michael; Schor, Ricardo

    2002-08-01

    We consider the energy-momentum excitation spectrum of diverse lattice Hamiltonian operators: the generator of the Markov semigroup of Ginzburg-Landau models with Langevin stochastic dynamics, the Hamiltonian of a scalar quantum field theory, and the Hamiltonian associated with the transfer matrix of a classical ferromagnetic spin system at high temperature. The low-lying spectrum consists of a one-particle state and a two-particle band. The two-particle spectrum is determined using a lattice version of the Bethe-Salpeter equation. In addition to the two-particle band, depending on the lattice dimension and on the attractive or repulsive character of the interaction between the particles of the system, there is, respectively, a bound state below or above the two-particle band. We show how the existence or nonexistence of these bound states can be understood in terms of a nonrelativistic single-particle lattice Schrödinger Hamiltonian with a delta potential. A staggering transformation relates the spectra of the attractive and the repulsive cases.

  7. Power loss measurement of implantable wireless power transfer components using a Peltier device balance calorimeter

    International Nuclear Information System (INIS)

    Leung, Ho Yan; Budgett, David M; Taberner, Andrew; Hu, Patrick

    2014-01-01

    Determining heat losses in power transfer components operating at high frequencies for implantable inductive power transfer systems is important for assessing whether the heat dissipated by the component is acceptable for implantation and medical use. However, this is a challenge at high frequencies and voltages due to limitations in electronic instrumentation. Calorimetric methods of power measurement are immune to the effects of high frequencies and voltages; hence, the measurement is independent of the electrical characteristics of the system. Calorimeters have been widely used to measure the losses of high power electrical components (>50 W), however it is more difficult to perform on low power components. This paper presents a novel power measurement method for components dissipating anywhere between 0.2 W and 1 W of power based on a heat balance calorimeter that uses a Peltier device as a balance sensor. The proposed balance calorimeter has a single test accuracy of ±0.042 W. The experimental results revealed that there was up to 35% difference between the power measurements obtained with electrical methods and the proposed calorimeter. (paper)

  8. Effects of Weekly Low-Frequency rTMS on Autonomic Measures in Children with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Manuel Fernando Casanova

    2014-10-01

    Full Text Available The term autism spectrum disorder (ASD describes a range of conditions characterized by impairments in social interactions, communication, and by restricted and repetitive behaviors. ASD may also present with symptoms suggestive of autonomic nervous system (ANS dysfunction. The objective of this study was to determine the effect of 18 sessions of low frequency repetitive transcranial magnetic stimulation (rTMS on autonomic function in children with ASD by recording electrocardiogram (EKG and electrodermal activity pre-, post- and during each rTMS session. The autonomic measures of interest in this study were R-R cardiointervals in EKG (R-R, time and frequency domain measures of heart rate variability (HRV and skin conductance level (SCL. HRV measures such as R-R intervals, standard deviation of cardiac intervals, pNN50 (percentage of cardiointervals>50 ms different from preceding interval, power of high frequency (HF and low frequency (LF components of HRV spectrum, LF/HF ratio, were then derived from the recorded EKG. We expected that the course of 18 weekly inhibitory low-frequency rTMS applied to the dorsolateral prefrontal cortex (DLPFC would enhance autonomic balance by facilitating frontal inhibition of limbic activity thus resulting in decreased overall heart rate, increased HRV (in a form of increased HF power, decreased LF power (resulting in decreased LF/HF ratio, and decreased SCL. Behavioral evaluations post-18 TMS showed decreased irritability, hyperactivity, stereotype behavior and compulsive behavior ratings while autonomic measures indicated a significant increase in cardiac interval variability and a decrease of tonic SCL. The results suggest that 18 sessions of low frequency rTMS in ASD results in increased cardiac vagal control and reduced sympathetic arousal.

  9. Test Review: Autism Spectrum Rating Scales

    Science.gov (United States)

    Simek, Amber N.; Wahlberg, Andrea C.

    2011-01-01

    This article reviews Autism Spectrum Rating Scales (ASRS) which are designed to measure behaviors in children between the ages of 2 and 18 that are associated with disorders on the autism spectrum as rated by parents/caregivers and/or teachers. The rating scales include items related to behaviors associated with Autism, Asperger's Disorder, and…

  10. Spectrum measurements in the ZENITH plutonium core 7 using a neutron chopper

    Energy Technology Data Exchange (ETDEWEB)

    Barclay, F R; Cameron, I R; Pitcher, H H.W.; Symons, C R [General Reactor Physics Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1964-05-15

    As part of the experimental programme on the first plutonium loading of ZENITH (Core 7) a series of measurements was carried out with the neutron chopper on a beam emerging from the core centre. The general experimental programme on the two ZENITH plutonium cores has been covered elsewhere. Core 7 had a carbon/Pu239 atomic ratio of 2666 and a steel/Pu239 ratio of 76.8, giving an absorption cross-section at 2200 m/sec. of 0.31 barns/carbon atom. The fuel was in the form of 'spikes' of 0.020 in. thick Pu/Al alloy sheathed in 0.020 in. aluminium, the isotopic composition of the plutonium being 97.4% Pu239, 2.55% Pu240 and 0.1% Pu241. The overall layout of the reactor core and reflector is shown in the vertical section through the reactor vessel and the plan view. The core consists of a vertical array of 235 cylindrical graphite sleeves of outer diameter 7.37 cm into each of which a cylindrical graphite box may be loaded. Sunning longitudinally inside the box are six parallel grooves which act as locations for the edges of either the Pu/Al spikes or graphite dummies of the same external dimensions. Each groove accommodates two spikes end-to-end, with a small graphite spacer between to avoid welding together of the spike sheaths when heated. Lateral spacers of graphite or stainless steel fill the five spaces between the six spikes or dummies. The total length of the plutonium-loaded core region is 140 cm, the ends of the element forming graphite reflectors of length 53 cm. In Core 7 each fuel element contained 10 Pu-Al spikes. The fuel elements are arranged in a triangular lattice of pitch 7.62 cm to form the reactor core, of diameter 1.23 m. A radial graphite reflector approximately 1 metre thick surrounds the core and is separated from it by an annular lampblack thermal barrier, contained within graphite tiles, which reduces heat transfer from the core. The reactor can be heated by circulation of nitrogen through a 250 kW heater below the core. The nitrogen flows

  11. Spectrum measurements in the ZENITH plutonium core 7 using a neutron chopper

    International Nuclear Information System (INIS)

    Barclay, F.R.; Cameron, I.R.; Pitcher, H.H.W.; Symons, C.R.

    1964-05-01

    As part of the experimental programme on the first plutonium loading of ZENITH (Core 7) a series of measurements was carried out with the neutron chopper on a beam emerging from the core centre. The general experimental programme on the two ZENITH plutonium cores has been covered elsewhere. Core 7 had a carbon/Pu239 atomic ratio of 2666 and a steel/Pu239 ratio of 76.8, giving an absorption cross-section at 2200 m/sec. of 0.31 barns/carbon atom. The fuel was in the form of 'spikes' of 0.020 in. thick Pu/Al alloy sheathed in 0.020 in. aluminium, the isotopic composition of the plutonium being 97.4% Pu239, 2.55% Pu240 and 0.1% Pu241. The overall layout of the reactor core and reflector is shown in the vertical section through the reactor vessel and the plan view. The core consists of a vertical array of 235 cylindrical graphite sleeves of outer diameter 7.37 cm into each of which a cylindrical graphite box may be loaded. Sunning longitudinally inside the box are six parallel grooves which act as locations for the edges of either the Pu/Al spikes or graphite dummies of the same external dimensions. Each groove accommodates two spikes end-to-end, with a small graphite spacer between to avoid welding together of the spike sheaths when heated. Lateral spacers of graphite or stainless steel fill the five spaces between the six spikes or dummies. The total length of the plutonium-loaded core region is 140 cm, the ends of the element forming graphite reflectors of length 53 cm. In Core 7 each fuel element contained 10 Pu-Al spikes. The fuel elements are arranged in a triangular lattice of pitch 7.62 cm to form the reactor core, of diameter 1.23 m. A radial graphite reflector approximately 1 metre thick surrounds the core and is separated from it by an annular lampblack thermal barrier, contained within graphite tiles, which reduces heat transfer from the core. The reactor can be heated by circulation of nitrogen through a 250 kW heater below the core. The nitrogen flows

  12. Spectrum and H(10) of secondary neutrons around Linacs

    International Nuclear Information System (INIS)

    Ortiz H, A.; Hernandez A, B.; Vega C, H. R.; Hernandez D, V. M.; Rivera M, T.

    2009-10-01

    Neutron spectrum and ambient dose equivalent has been measured around two 10 MV linear accelerators. Accelerators are Siemens, one is a Mevatron model while another is the Primus. Main differences between those models are the beam collimator and the vault room. Here, Bonner sphere spectrometer with a passive thermal neutron detector has been utilized to measure the neutron spectrum inside the vault. Using an active detector the neutron spectrum was measured by the vaults door of both accelerators. With a neutron area monitor the dose equivalent was measured by the doors. Neutron strength, total fluence rate and ambient dose equivalent were compared, from this was found that shielding conditions are better in the Primus model. (Author)

  13. 66Ga ground state β spectrum

    DEFF Research Database (Denmark)

    Severin, Gregory; Knutson, L. D.; Voytas, P. A.

    2014-01-01

    The ground state branch of the β decay of 66Ga is an allowed Fermi (0+ → 0+) transition with a relatively high f t value. The large f t and the isospin-forbidden nature of the transition indicates that the shape of the β spectrum of this branch may be sensitive to higher order contributions...... to the decay. Two previous measurements of the shape have revealed deviations from an allowed spectrum but disagree about whether the shape factor has a positive or negative slope. As a test of a new iron-free superconducting β spectrometer, we have measured the shape of the ground state branch of the 66Ga β...... spectrum above a positron energy of 1.9 MeV. The spectrum is consistent with an allowed shape, with the slope of the shape factor being zero to within ±3 × 10−3 per MeV. We have also determined the endpoint energy for the ground state branch to be 4.1535 ± 0.0003 (stat.) ±0.0007 (syst.) MeV, in good...

  14. A new approach to the measurement of adaptive behavior: development of the PEDI-CAT for children and youth with autism spectrum disorders

    NARCIS (Netherlands)

    Kramer, J.M.; Coster, W.J.; Kao, Y.C.; Snow, A.; Orsmond, G.I.

    2012-01-01

    The use of current adaptive behavior measures in practice and research is limited by their length and need for a professional interviewer. There is a need for alternative measures that more efficiently assess adaptive behavior in children and youth with autism spectrum disorders (ASDs). The

  15. Frequency-resolved measurement of the orbital angular momentum spectrum of femtosecond ultra-broadband optical-vortex pulses based on field reconstruction

    International Nuclear Information System (INIS)

    Yamane, Keisaku; Yang, Zhili; Toda, Yasunori; Morita, Ryuji

    2014-01-01

    We propose a high-precision method for measuring the orbital angular momentum (OAM) spectrum of ultra-broadband optical-vortex (OV) pulses from fork-like interferograms between OV pulses and a reference plane-wave pulse. It is based on spatial reconstruction of the electric fields of the pulses to be measured from the frequency-resolved interference pattern. Our method is demonstrated experimentally by obtaining the OAM spectra for different spectral components of the OV pulses, enabling us to characterize the frequency dispersion of the topological charge of the OAM spectrum by a simple experimental setup. Retrieval is carried out in quasi-real time, allowing us to investigate OAM spectra dynamically. Furthermore, we determine the relative phases (including the sign) of the topological-charge-resolved electric-field amplitudes, which are significant for evaluating OVs or OV pulses with arbitrarily superposed modes. (paper)

  16. The U238 antineutrino spectrum in the Double Chooz experiment

    Energy Technology Data Exchange (ETDEWEB)

    Haag, Nils; Oberauer, Lothar; Potzel, Walter; Schreckenbach, Klaus [Technische Universitaet, Muenchen (Germany); Lachenmaier, Tobias [Eberhard Karls Universitaet, Tuebingen (Germany)

    2011-07-01

    The DoubleChooz experiment aims at the determination of the unknown neutrino mixing parameter {Theta}{sub 13}. Two liquid scintillator detectors will measure an electron antineutrino disappearance at the Chooz site in the French ardennes. In order to improve the sensitivity, the antineutrino spectrum emitted by the Chooz reactor cores has to be determined with high accuracy. This talk focusses on the U238 spectrum, which is the only contributing spectrum, that was not measured until now. The final U238 beta spectrum is presented, and its implementation into the analysis framework is shown.

  17. Development of an antibiotic spectrum score based on veterans affairs culture and susceptibility data for the purpose of measuring antibiotic de-escalation: a modified Delphi approach.

    Science.gov (United States)

    Madaras-Kelly, Karl; Jones, Makoto; Remington, Richard; Hill, Nicole; Huttner, Benedikt; Samore, Matthew

    2014-09-01

    Development of a numerical score to measure the microbial spectrum of antibiotic regimens (spectrum score) and method to identify antibiotic de-escalation events based on application of the score. Web-based modified Delphi method. Physician and pharmacist antimicrobial stewards practicing in the United States recruited through infectious diseases-focused listservs. Three Delphi rounds investigated: organisms and antibiotics to include in the spectrum score, operationalization of rules for the score, and de-escalation measurement. A 4-point ordinal scale was used to score antibiotic susceptibility for organism-antibiotic domain pairs. Antibiotic regimen scores, which represented combined activity of antibiotics in a regimen across all organism domains, were used to compare antibiotic spectrum administered early (day 2) and later (day 4) in therapy. Changes in spectrum score were calculated and compared with Delphi participants' judgments on de-escalation with 20 antibiotic regimen vignettes and with non-Delphi steward judgments on de-escalation of 300 pneumonia regimen vignettes. Method sensitivity and specificity to predict expert de-escalation status were calculated. Twenty-four participants completed all Delphi rounds. Expert support for concepts utilized in metric development was identified. For vignettes presented in the Delphi, the sign of change in score correctly classified de-escalation in all vignettes except those involving substitution of oral antibiotics. The sensitivity and specificity of the method to identify de-escalation events as judged by non-Delphi stewards were 86.3% and 96.0%, respectively. Identification of de-escalation events based on an algorithm that measures microbial spectrum of antibiotic regimens generally agreed with steward judgments of de-escalation status.

  18. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    International Nuclear Information System (INIS)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-01-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band (<5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is -110 dB/Hz, with uncertainty ≤0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by ≤0.2 dB. [copyright] 2001 Optical Society of America

  19. Discrete-ordinates finite-element method for atmospheric radiative transfer and remote sensing

    International Nuclear Information System (INIS)

    Gerstl, S.A.W.; Zardecki, A.

    1985-01-01

    Advantages and disadvantages of modern discrete-ordinates finite-element methods for the solution of radiative transfer problems in meteorology, climatology, and remote sensing applications are evaluated. After the common basis of the formulation of radiative transfer problems in the fields of neutron transport and atmospheric optics is established, the essential features of the discrete-ordinates finite-element method are described including the limitations of the method and their remedies. Numerical results are presented for 1-D and 2-D atmospheric radiative transfer problems where integral as well as angular dependent quantities are compared with published results from other calculations and with measured data. These comparisons provide a verification of the discrete-ordinates results for a wide spectrum of cases with varying degrees of absorption, scattering, and anisotropic phase functions. Accuracy and computational speed are also discussed. Since practically all discrete-ordinates codes offer a builtin adjoint capability, the general concept of the adjoint method is described and illustrated by sample problems. Our general conclusion is that the strengths of the discrete-ordinates finite-element method outweight its weaknesses. We demonstrate that existing general-purpose discrete-ordinates codes can provide a powerful tool to analyze radiative transfer problems through the atmosphere, especially when 2-D geometries must be considered

  20. Methods of neutron spectrum calculation from measured reaction rates in saips. Part 1. Review of mathematical methods

    International Nuclear Information System (INIS)

    Bondars, Kh.Ya.; Lapenas, A.A.

    1981-01-01

    We adapted or used on ES EhVM, operating under the control of OS ES, the currently most common algorithms for calculating neutron spectra from measured reaction rates. These programs, together with the neutron cross-section and spectrum libraries, are part of the computerized information system SAIPS. The present article descibes the basic mathematical concepts used in the algorithms of the SAIPS calculation programs

  1. First measurement of radon transfer. Water - skin - blood - air

    International Nuclear Information System (INIS)

    Philipsborn, H. von; Grunewald, W.A.

    2000-01-01

    While radon is disliked in uranium mines and homes, it is used medically in radon spas for the treatment of several ailments. The transfer of radon gas from water, through skin into blood and into expiratory air was studied completely for the first time for a person resting 20-30 min in radon water. For waterborne radon concentrations of 1500±100 Bq/L, 4±1 Bq/L were measured in the blood and 2.4±0.5 kBq/m 3 (Bq/L) in the expiratory air. The results can be understood according to the principles of physiology. The nature of the experiments excluded persons other than the authors. Hence the study has been radiometric (physical), not clinical (medical). (orig.)

  2. Further development of a track detector as the spectrometer of linear energy transfer

    International Nuclear Information System (INIS)

    Spurny, F.; Bednar, J.; Vlcek, B.; Botollier-Depois, J.F.

    1998-01-01

    Track revealing in a track etch detector is a phenomenon related to the linear energy transfer (LET) of the particle registered. The measurements of track parameters permit to determine the LET corresponding to each revealed track, i.e. LET spectrum. We have recently developed a spectrometer of LET based on the chemically etched polyallyldiglycolcarbonate (PADC). In this contribution the results obtained with such spectrometer in some neutron fields are presented, analyzed and discussed. Several radionuclide neutron sources have been used, LET spectrometer has been also exposed in high energy neutron reference fields at CERN and JINR Dubna, and on board aircraft. (author)

  3. Proton Linear Energy Transfer measurement using Emulsion Cloud Chamber

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jae-ik [Proton Therapy Center, National Cancer Center (Korea, Republic of); Division of Heavy Ion Clinical Research, Korea Institute of Radiological & Medical Sciences (KIRAMS), Seoul (Korea, Republic of); Park, Seyjoon [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University, School of Medicine, Seoul (Korea, Republic of); Kim, Haksoo; Kim, Meyoung [Proton Therapy Center, National Cancer Center (Korea, Republic of); Jeong, Chiyoung [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Cho, Sungkoo [Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University, School of Medicine, Seoul (Korea, Republic of); Lim, Young Kyung; Shin, Dongho [Proton Therapy Center, National Cancer Center (Korea, Republic of); Lee, Se Byeong, E-mail: sblee@ncc.re.kr [Proton Therapy Center, National Cancer Center (Korea, Republic of); Morishima, Kunihiro; Naganawa, Naotaka; Sato, Osamu [Department of Physics, Nagoya University, Nagoya (Japan); Kwak, Jungwon [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Sung Hyun [Center for Underground Physics, Institute for Basic Science (IBS), Daejeon (Korea, Republic of); Cho, Jung Sook [Department of refinement education, Dongseo University, Busan (Korea, Republic of); Ahn, Jung Keun [Department of Physics, Korea University, Seoul (Korea, Republic of); Kim, Ji Hyun; Yoon, Chun Sil [Gyeongsang National University, Jinju (Korea, Republic of); Incerti, Sebastien [CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan (France); Université Bordeaux 1, CENBG, UMR 5797, F-33170 Gradignan (France)

    2015-04-15

    This study proposes to determine the correlation between the Volume Pulse Height (VPH) measured by nuclear emulsion and Linear Energy Transfer (LET) calculated by Monte Carlo simulation based on Geant4. The nuclear emulsion was irradiated at the National Cancer Center (NCC) with a therapeutic proton beam and was installed at 5.2 m distance from the beam nozzle structure with various thicknesses of water-equivalent material (PMMA) blocks to position with specific positions along the Bragg curve. After the beam exposure and development of the emulsion films, the films were scanned by S-UTS developed in Nagoya University. The proton tracks in the scanned films were reconstructed using the ‘NETSCAN’ method. Through this procedure, the VPH can be derived from each reconstructed proton track at each position along the Bragg curve. The VPH value indicates the magnitude of energy loss in proton track. By comparison with the simulation results obtained using Geant4, we found the correlation between the LET calculated by Monte Carlo simulation and the VPH measured by the nuclear emulsion.

  4. Proton Linear Energy Transfer measurement using Emulsion Cloud Chamber

    International Nuclear Information System (INIS)

    Shin, Jae-ik; Park, Seyjoon; Kim, Haksoo; Kim, Meyoung; Jeong, Chiyoung; Cho, Sungkoo; Lim, Young Kyung; Shin, Dongho; Lee, Se Byeong; Morishima, Kunihiro; Naganawa, Naotaka; Sato, Osamu; Kwak, Jungwon; Kim, Sung Hyun; Cho, Jung Sook; Ahn, Jung Keun; Kim, Ji Hyun; Yoon, Chun Sil; Incerti, Sebastien

    2015-01-01

    This study proposes to determine the correlation between the Volume Pulse Height (VPH) measured by nuclear emulsion and Linear Energy Transfer (LET) calculated by Monte Carlo simulation based on Geant4. The nuclear emulsion was irradiated at the National Cancer Center (NCC) with a therapeutic proton beam and was installed at 5.2 m distance from the beam nozzle structure with various thicknesses of water-equivalent material (PMMA) blocks to position with specific positions along the Bragg curve. After the beam exposure and development of the emulsion films, the films were scanned by S-UTS developed in Nagoya University. The proton tracks in the scanned films were reconstructed using the ‘NETSCAN’ method. Through this procedure, the VPH can be derived from each reconstructed proton track at each position along the Bragg curve. The VPH value indicates the magnitude of energy loss in proton track. By comparison with the simulation results obtained using Geant4, we found the correlation between the LET calculated by Monte Carlo simulation and the VPH measured by the nuclear emulsion

  5. Proton Linear Energy Transfer measurement using Emulsion Cloud Chamber

    Science.gov (United States)

    Shin, Jae-ik; Park, Seyjoon; Kim, Haksoo; Kim, Meyoung; Jeong, Chiyoung; Cho, Sungkoo; Lim, Young Kyung; Shin, Dongho; Lee, Se Byeong; Morishima, Kunihiro; Naganawa, Naotaka; Sato, Osamu; Kwak, Jungwon; Kim, Sung Hyun; Cho, Jung Sook; Ahn, Jung Keun; Kim, Ji Hyun; Yoon, Chun Sil; Incerti, Sebastien

    2015-04-01

    This study proposes to determine the correlation between the Volume Pulse Height (VPH) measured by nuclear emulsion and Linear Energy Transfer (LET) calculated by Monte Carlo simulation based on Geant4. The nuclear emulsion was irradiated at the National Cancer Center (NCC) with a therapeutic proton beam and was installed at 5.2 m distance from the beam nozzle structure with various thicknesses of water-equivalent material (PMMA) blocks to position with specific positions along the Bragg curve. After the beam exposure and development of the emulsion films, the films were scanned by S-UTS developed in Nagoya University. The proton tracks in the scanned films were reconstructed using the 'NETSCAN' method. Through this procedure, the VPH can be derived from each reconstructed proton track at each position along the Bragg curve. The VPH value indicates the magnitude of energy loss in proton track. By comparison with the simulation results obtained using Geant4, we found the correlation between the LET calculated by Monte Carlo simulation and the VPH measured by the nuclear emulsion.

  6. Local Measurement of Fuel Energy Deposition and Heat Transfer Environment During Fuel Lifetime Using Controlled Calorimetry

    International Nuclear Information System (INIS)

    Don W. Miller; Andrew Kauffmann; Eric Kreidler; Dongxu Li; Hanying Liu; Daniel Mills; Thomas D. Radcliff; Joseph Talnagi

    2001-01-01

    A comprehensive description of the accomplishments of the DOE grant titled, ''Local Measurement of Fuel Energy Deposition and Heat Transfer Environment During Fuel Lifetime using Controlled Calorimetry''

  7. Measuring the Level of Socialization in Children with Autism Spectrum Disorder

    Directory of Open Access Journals (Sweden)

    Khaustov A.V.,

    2016-10-01

    Full Text Available Difficulties with socialization common for children with autism spectrum disorder (ASD are a serious problem for their inclusion into educational settings. These socialization deficits are basically related to underdeveloped social skills. The paper describes a study aimed at revealing the level of socialization in children with ASD. The study involved 117 children aged 5–7 years and their parents. The children’s socialization level was measured with the Vineland Adaptive Behavior Scale. The outcomes showed that most children with ASD display low levels of socialization resulting in their inability to adequately communicate and cooperate with other people as in play, as in everyday life. Two factors were found to affect the level of socialization in the children: deficit of motivation and specific cognitive impairments. The paper argues for the necessity of developing a program for psychologi- cal and educational assistance aimed at forming social skills in children with ASD.

  8. Spectrum 101: An Introduction to Spectrum Management

    Science.gov (United States)

    2004-03-01

    produces a Joint Restricted Frequency List (JRFL). The JFRL consolidates and classifies the spectrum uses that are most critical to operations and to...Management Office JRFL Joint Restricted Frequency List JSC Joint Spectrum Center JSIR Joint Spectrum Interference Resolution JSME Joint Spectrum...Multifunctional Information Distribution System MILSATCOM Military Satellite Communications MOA Memorandum of Agreement MRFL Master Radio Frequency

  9. Brief Measures of Anxiety in Non-Treatment-Seeking Youth with Autism Spectrum Disorder

    Science.gov (United States)

    Kerns, Connor Morrow; Maddox, Brenna B.; Kendall, Philip C.; Rump, Keiran; Berry, Leandra; Schultz, Robert T.; Souders, Margaret C.; Bennett, Amanda; Herrington, John; Miller, Judith

    2015-01-01

    This study investigated the accuracy of brief anxiety scales for non-treatment-seeking youth with autism spectrum disorder. In all, 54 youth (7-17?years; IQ: 67-158) with autism spectrum disorder and their parents completed (a) an expanded version of the Anxiety Disorders Interview Schedule--Child/Parent designed to capture typical and atypical…

  10. {sup 252}Cf spontaneous prompt fission neutron spectrum measured at 0 degree and 180 degree relative to the fragment motion

    Energy Technology Data Exchange (ETDEWEB)

    Shanglian, Bao; Jinquan, Liu [Beijing Univ., BJ (China); Batenkov, O I; Blinov, M V; Smirnov, S N [V.G. Khlopin Radium Institute, ST. Petersburg (Russian Federation)

    1994-09-01

    The {sup 252}Cf spontaneous prompt fission neutron spectrum at 0 degree and 180 degree relative to the motion direction of corresponding fission fragments was measured. High angular resolution for fragment measurements and high energy resolution for neutron measurements were obtained using multi-parameter TOF spectrometer. The results showed that there is a symmetric distribution of `forward` and `backward` for low energy in C.M.S. neutrons, which was an evidence of nonequilibrium neutrons existed in fission process.

  11. Theoretical models for the muon spectrum at sea level

    International Nuclear Information System (INIS)

    Abdel-Monem, M.S.; Benbrook, J.R.; Osborne, A.R.; Sheldon, W.R.

    1975-01-01

    The absolute vertical cosmic ray muon spectrum is investigated theoretically. Models of high energy interactions (namely, Maeda-Cantrell (MC), Constant Energy (CE), Cocconi-Koester-Perkins (CKP) and Scaling Models) are used to calculate the spectrum of cosmic ray muons at sea level. A comparison is made between the measured spectrum and that predicted from each of the four theoretical models. It is concluded that the recently available measured muon differential intensities agree with the scaling model for energies less than 100 GeV and with the CKP model for energies greater than 200 GeV. The measured differential intensities (Abdel-Monem et al.) agree with scaling. (orig.) [de

  12. 78 FR 50399 - Spectrum Monitoring Pilot Program

    Science.gov (United States)

    2013-08-19

    ... 130809703-3703-01] RIN 0660-XC007 Spectrum Monitoring Pilot Program AGENCY: National Telecommunications and... National Telecommunications and Information Administration (NTIA) to design and conduct a pilot program to... investment for a two-year pilot program to determine the benefits of an automated spectrum measurement and...

  13. Estimation of internal heat transfer coefficients and detection of rib positions in gas turbine blades from transient surface temperature measurements

    International Nuclear Information System (INIS)

    Heidrich, P; Wolfersdorf, J v; Schmidt, S; Schnieder, M

    2008-01-01

    This paper describes a non-invasive, non-destructive, transient inverse measurement technique that allows one to determine internal heat transfer coefficients and rib positions of real gas turbine blades from outer surface temperature measurements after a sudden flow heating. The determination of internal heat transfer coefficients is important during the design process to adjust local heat transfer to spatial thermal load. The detection of rib positions is important during production to fulfill design and quality requirements. For the analysis the one-dimensional transient heat transfer problem inside of the turbine blade's wall was solved. This solution was combined with the Levenberg-Marquardt method to estimate the unknown boundary condition by an inverse technique. The method was tested with artificial data to determine uncertainties with positive results. Then experimental testing with a reference model was carried out. Based on the results, it is concluded that the presented inverse technique could be used to determine internal heat transfer coefficients and to detect rib positions of real turbine blades.

  14. Measurement of a Peak in the Cosmic Microwave Background Power Spectrum from the North American test flight of BOOMERANG

    CERN Document Server

    Mauskopf, P D; De Bernardis, P; Bock, J J; Borrill, J; Boscaleri, A; Crill, B P; De Gasperis, G; De Troia, G; Farese, P; Ferreira, P G; Ganga, K; Giacometti, M; Hanany, S; Hristov, V V; Iacoangeli, A; Jaffe, A H; Lange, A E; Lee, A T; Masi, S; Melchiorri, A; Melchiorri, F; Miglio, L; Montroy, T; Netterfield, C B; Pascale, E; Piacentini, F; Richards, P L; Romeo, G; Ruhl, J E; Scannapieco, E S; Scaramuzzi, F; Stompor, R; Vittorio, N

    2000-01-01

    We describe a measurement of the angular power spectrum of anisotropies in the Cosmic Microwave Background (CMB) from 0.3 degrees to ~10 degrees from the North American test flight of the BOOMERANG experiment. BOOMERANG is a balloon-borne telescope with a bolometric receiver designed to map CMB anisotropies on a Long Duration Balloon flight. During a 6-hour test flight of a prototype system in 1997, we mapped > 200 square degrees at high galactic latitudes in two bands centered at 90 and 150 GHz with a resolution of 26 and 16.6 arcmin FWHM respectively. Analysis of the maps gives a power spectrum with a peak at angular scales of ~1 degree with an amplitude ~70 uK.

  15. Measurement of the Cosmic-Ray Antiproton Spectrum at Solar Minimum with a Long-Duration Balloon Flight over Antarctica

    Science.gov (United States)

    Abe, K.; Fuke, H.; Haino, S.; Hams, T.; Hasegawa, M.; Horikoshi, A.; Kim, K. C.; Kusumoto, A.; Lee, M. H.; Makida, Y.; hide

    2012-01-01

    The energy spectrum of cosmic-ray antiprotons (p-bar's) from 0.17 to 3.5 GeV has been measured using 7886 p-bar's detected by BESS-Polar II during a long-duration flight over Antarctica near solar minimum in December 2007 and January 2008. This shows good consistency with secondary p-bar calculations. Cosmologically primary p-bar's have been investigated by comparing measured and calculated p-bar spectra. BESS-Polar II data.show no evidence of primary p-bar's from the evaporation of primordial black holes.

  16. Radioecology. Transfers of radioelements

    International Nuclear Information System (INIS)

    Foulquier, L.

    2002-01-01

    The study of the cycle of radioelements in the environment requires the measurement of the radionuclides present in all parts of the ecosystems. The knowledge of the mechanisms of radioactive pollutant transfers and of the kinetics of the exchanges between a source term, the vectors and the constituents of the biosphere represents heart of the work of radio-ecologists. This article describes briefly the techniques used for the measurement of radionuclides in the environment and for the study of their physical dispersion mechanisms. Then, it treats more carefully of the transfer mechanisms in different environments: 1 - tools for the evaluation of transfers: metrology, atmospheric and liquid dispersion phenomena; 2 - processes of radioelement transfers: transfers in aquatic ecosystems, transfers in terrestrial environment. (J.S.)

  17. Angular power spectrum of galaxies in the 2MASS Redshift Survey

    Science.gov (United States)

    Ando, Shin'ichiro; Benoit-Lévy, Aurélien; Komatsu, Eiichiro

    2018-02-01

    We present the measurement and interpretation of the angular power spectrum of nearby galaxies in the 2MASS Redshift Survey catalogue with spectroscopic redshifts up to z ≈ 0.1. We detect the angular power spectrum up to a multipole of ℓ ≈ 1000. We find that the measured power spectrum is dominated by galaxies living inside nearby galaxy clusters and groups. We use the halo occupation distribution (HOD) formalism to model the power spectrum, obtaining a fit with reasonable parameters. These HOD parameters are in agreement with the 2MASS galaxy distribution we measure towards the known nearby galaxy clusters, confirming validity of our analysis.

  18. Measurements of neutron spectrum from uranium converter

    International Nuclear Information System (INIS)

    Ninkovic, M.; Sotic, O.; Marinkovic, S.

    1978-01-01

    The procedure for determination of energetic distribution of neutrons by the multisphere technique is given. The theoretical basis and features of the method are explained. The spectral distribution of neutrons emerging from the neutron converter constructed at the bare reactor assembly RB, has been determined applying the existing computer programme and literature data for the energetic dependence functions of spheres of various diameters. The obtained spectral distribution has a specific maximum in the domain of fast neutrons, justifying thus the reacton for the construction of the converter. The neutron spectrum data obtained and given in this report are very important for the use of the converter in neutron dosimetry and radiation protection, as well as in the radiobiology, shielding, reactor physics etc. (author)

  19. Addressing challenges of modulation transfer function measurement with fisheye lens cameras

    Science.gov (United States)

    Deegan, Brian M.; Denny, Patrick E.; Zlokolica, Vladimir; Dever, Barry; Russell, Laura

    2015-03-01

    Modulation transfer function (MTF) is a well defined and accepted method of measuring image sharpness. The slanted edge test, as defined in ISO12233 is a standard method of calculating MTF, and is widely used for lens alignment and auto-focus algorithm verification. However, there are a number of challenges which should be considered when measuring MTF in cameras with fisheye lenses. Due to trade-offs related Petzval curvature, planarity of the optical plane is difficult to achieve in fisheye lenses. It is therefore critical to have the ability to accurately measure sharpness throughout the entire image, particularly for lens alignment. One challenge for fisheye lenses is that, because of the radial distortion, the slanted edges will have different angles, depending on the location within the image and on the distortion profile of the lens. Previous work in the literature indicates that MTF measurements are robust for angles between 2 and 10 degrees. Outside of this range, MTF measurements become unreliable. Also, the slanted edge itself will be curved by the lens distortion, causing further measurement problems. This study summarises the difficulties in the use of MTF for sharpness measurement in fisheye lens cameras, and proposes mitigations and alternative methods.

  20. Heat Transfer and Fluid Dynamics Measurements in the Expansion Space of a Stirling Cycle Engine

    Science.gov (United States)

    Jiang, Nan; Simon, Terrence W.

    2006-01-01

    The heater (or acceptor) of a Stirling engine, where most of the thermal energy is accepted into the engine by heat transfer, is the hottest part of the engine. Almost as hot is the adjacent expansion space of the engine. In the expansion space, the flow is oscillatory, impinging on a two-dimensional concavely-curved surface. Knowing the heat transfer on the inside surface of the engine head is critical to the engine design for efficiency and reliability. However, the flow in this region is not well understood and support is required to develop the CFD codes needed to design modern Stirling engines of high efficiency and power output. The present project is to experimentally investigate the flow and heat transfer in the heater head region. Flow fields and heat transfer coefficients are measured to characterize the oscillatory flow as well as to supply experimental validation for the CFD Stirling engine design codes. Presented also is a discussion of how these results might be used for heater head and acceptor region design calculations.

  1. Systematic review of tools to measure outcomes for young children with autism spectrum disorder.

    Science.gov (United States)

    McConachie, Helen; Parr, Jeremy R; Glod, Magdalena; Hanratty, Jennifer; Livingstone, Nuala; Oono, Inalegwu P; Robalino, Shannon; Baird, Gillian; Beresford, Bryony; Charman, Tony; Garland, Deborah; Green, Jonathan; Gringras, Paul; Jones, Glenys; Law, James; Le Couteur, Ann S; Macdonald, Geraldine; McColl, Elaine M; Morris, Christopher; Rodgers, Jacqueline; Simonoff, Emily; Terwee, Caroline B; Williams, Katrina

    2015-06-01

    The needs of children with autism spectrum disorder (ASD) are complex and this is reflected in the number and diversity of outcomes assessed and measurement tools used to collect evidence about children's progress. Relevant outcomes include improvement in core ASD impairments, such as communication, social awareness, sensory sensitivities and repetitiveness; skills such as social functioning and play; participation outcomes such as social inclusion; and parent and family impact. To examine the measurement properties of tools used to measure progress and outcomes in children with ASD up to the age of 6 years. To identify outcome areas regarded as important by people with ASD and parents. The MeASURe (Measurement in Autism Spectrum disorder Under Review) research collaboration included ASD experts and review methodologists. We undertook systematic review of tools used in ASD early intervention and observational studies from 1992 to 2013; systematic review, using the COSMIN checklist (Consensus-based Standards for the selection of health Measurement Instruments) of papers addressing the measurement properties of identified tools in children with ASD; and synthesis of evidence and gaps. The review design and process was informed throughout by consultation with stakeholders including parents, young people with ASD, clinicians and researchers. The conceptual framework developed for the review was drawn from the International Classification of Functioning, Disability and Health, including the domains 'Impairments', 'Activity Level Indicators', 'Participation', and 'Family Measures'. In review 1, 10,154 papers were sifted - 3091 by full text - and data extracted from 184; in total, 131 tools were identified, excluding observational coding, study-specific measures and those not in English. In review 2, 2665 papers were sifted and data concerning measurement properties of 57 (43%) tools were extracted from 128 papers. Evidence for the measurement properties of the reviewed

  2. Tunneling dynamics of double proton transfer in formic acid and benzoic acid dimers

    Science.gov (United States)

    Smedarchina, Zorka; Fernández-Ramos, Antonio; Siebrand, Willem

    2005-04-01

    Direct dynamics calculations based on instanton techniques are reported of tunneling splittings due to double proton transfer in formic and benzoic acid dimers. The results are used to assign the observed splittings to levels for which the authors of the high-resolution spectra could not provide a definitive assignment. In both cases the splitting is shown to be due mainly to the zero-point level rather than to the vibrationally or electronically excited level whose spectrum was investigated. This leads to zero-point splittings of 375MHz for (DCOOH)2 and 1107MHz for the benzoic acid dimer. Thus, contrary to earlier calculations, it is found that the splitting is considerably larger in the benzoic than in the formic acid dimer. The calculations are extended to solid benzoic acid where the asymmetry of the proton-transfer potential induced by the crystal can be overcome by suitable doping. This has allowed direct measurement of the interactions responsible for double proton transfer, which were found to be much larger than those in the isolated dimer. To account for this observation both static and dynamic effects of the crystal forces on the intradimer hydrogen bonds are included in the calculations. The same methodology, extended to higher temperatures, is used to calculate rate constants for HH, HD, and DD transfers in neat benzoic acid crystals. The results are in good agreement with reported experimental rate constants measured by NMR relaxometry and, if allowance is made for small structural changes induced by doping, with the transfer matrix elements observed in doped crystals. Hence the method used allows a unified description of tunneling splittings in the gas phase and in doped crystals as well as of transfer rates in neat crystals.

  3. Electrochemical Measurement of Electron Transfer Kinetics by Shewanella oneidensis MR-1*

    Science.gov (United States)

    Baron, Daniel; LaBelle, Edward; Coursolle, Dan; Gralnick, Jeffrey A.; Bond, Daniel R.

    2009-01-01

    Shewanella oneidensis strain MR-1 can respire using carbon electrodes and metal oxyhydroxides as electron acceptors, requiring mechanisms for transferring electrons from the cell interior to surfaces located beyond the cell. Although purified outer membrane cytochromes will reduce both electrodes and metals, S. oneidensis also secretes flavins, which accelerate electron transfer to metals and electrodes. We developed techniques for detecting direct electron transfer by intact cells, using turnover and single turnover voltammetry. Metabolically active cells attached to graphite electrodes produced thin (submonolayer) films that demonstrated both catalytic and reversible electron transfer in the presence and absence of flavins. In the absence of soluble flavins, electron transfer occurred in a broad potential window centered at ∼0 V (versus standard hydrogen electrode), and was altered in single (ΔomcA, ΔmtrC) and double deletion (ΔomcA/ΔmtrC) mutants of outer membrane cytochromes. The addition of soluble flavins at physiological concentrations significantly accelerated electron transfer and allowed catalytic electron transfer to occur at lower applied potentials (−0.2 V). Scan rate analysis indicated that rate constants for direct electron transfer were slower than those reported for pure cytochromes (∼1 s−1). These observations indicated that anodic current in the higher (>0 V) window is due to activation of a direct transfer mechanism, whereas electron transfer at lower potentials is enabled by flavins. The electrochemical dissection of these activities in living cells into two systems with characteristic midpoint potentials and kinetic behaviors explains prior observations and demonstrates the complementary nature of S. oneidensis electron transfer strategies. PMID:19661057

  4. Measuring Neutron Spectrum at MIT Research Reactor Utilizing He-3 Bonner Cylinder Approach with an Unfolding Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Leder, A. [MIT; Anderson, A. J. [Chicago U., KICP; Billard, J. [Lyon, IPN; Figueroa-Feliciano, E. [Northwestern U.; Formaggio, J. A. [MIT; Hasselkus, C. [Wisconsin U., Madison; Newman, E. [MIT; Palladino, K. [Wisconsin U., Madison; Phuthi, M. [MIT; Winslow, L. [MIT; Zhang, L. [MIT

    2017-10-02

    The Ricochet experiment seeks to measure Coherent (neutral-current) Elastic Neutrino-Nucleus Scattering using dark-matter-style detectors with sub-keV thresholds placed near a neutrino source, such as the MIT (research) Reactor (MITR), which operates at 5.5 MW generating approximately 2.2e18 neutrinos/second at the core. Currently, Ricochet is characterizing the backgrounds at MITR, the main component of which comes in the form of neutrons emitted from the core simultaneous with the neutrino signal. To characterize this background, we wrapped a Bonner cylinder around a He-3 thermal neutron detector, whose data was then unfolded to produce a neutron energy spectrum across several orders of magnitude. We discuss the resulting spectrum and its implications for deploying Ricochet in the future at the MITR site as well as the feasibility of reducing this background level via the addition of polyethylene shielding around the detector setup.

  5. Spectrum

    DEFF Research Database (Denmark)

    Høgfeldt Hansen, Leif

    2016-01-01

    The publication functions as a proces description of the development and construction of an urban furniture SPECTRUM in the city of Gwangju, Republic of Korea. It is used as the cataloque for the exhibition of Spectrum.......The publication functions as a proces description of the development and construction of an urban furniture SPECTRUM in the city of Gwangju, Republic of Korea. It is used as the cataloque for the exhibition of Spectrum....

  6. A New Approach to the Measurement of Adaptive Behavior: Development of the PEDI-CAT for Children and Youth with Autism Spectrum Disorders

    Science.gov (United States)

    Kramer, Jessica M.; Coster, Wendy J.; Kao, Ying-Chia; Snow, Anne; Orsmond, Gael I.

    2012-01-01

    The use of current adaptive behavior measures in practice and research is limited by their length and need for a professional interviewer. There is a need for alternative measures that more efficiently assess adaptive behavior in children and youth with autism spectrum disorders (ASDs). The Pediatric Evaluation of Disability Inventory-Computer…

  7. Acoustic and Perceptual Measurements of Prosody Production on the Profiling Elements of Prosodic Systems in Children by Children with Autism Spectrum Disorders

    Science.gov (United States)

    Diehl, Joshua John; Paul, Rhea

    2013-01-01

    Prosody production atypicalities are a feature of autism spectrum disorders (ASDs), but behavioral measures of performance have failed to provide detail on the properties of these deficits. We used acoustic measures of prosody to compare children with ASDs to age-matched groups with learning disabilities and typically developing peers. Overall,…

  8. The rotational spectrum of IBr

    International Nuclear Information System (INIS)

    Tiemann, E.; Moeller, T.

    1975-01-01

    The microwave spectrum of IBr was measured in the low rotational transition J = 3 → 2 in order to resolve the hyperfine structure as completely as possible. Rotational constants and quadrupole coupling constants were derived for both nuclei. The observation of the rotational spectrum in different vibrational states yields the vibrational dependence of the rotational constants as well as of the hyperfine parameters. The Dunham potential coefficients α 0 , α 1 , α 2 , α 3 are given. (orig.) [de

  9. Gradient flux measurements of sea–air DMS transfer during the Surface Ocean Aerosol Production (SOAP experiment

    Directory of Open Access Journals (Sweden)

    M. J. Smith

    2018-04-01

    Full Text Available Direct measurements of marine dimethylsulfide (DMS fluxes are sparse, particularly in the Southern Ocean. The Surface Ocean Aerosol Production (SOAP voyage in February–March 2012 examined the distribution and flux of DMS in a biologically active frontal system in the southwest Pacific Ocean. Three distinct phytoplankton blooms were studied with oceanic DMS concentrations as high as 25 nmol L−1. Measurements of DMS fluxes were made using two independent methods: the eddy covariance (EC technique using atmospheric pressure chemical ionization–mass spectrometry (API-CIMS and the gradient flux (GF technique from an autonomous catamaran platform. Catamaran flux measurements are relatively unaffected by airflow distortion and are made close to the water surface, where gas gradients are largest. Flux measurements were complemented by near-surface hydrographic measurements to elucidate physical factors influencing DMS emission. Individual DMS fluxes derived by EC showed significant scatter and, at times, consistent departures from the Coupled Ocean–Atmosphere Response Experiment gas transfer algorithm (COAREG. A direct comparison between the two flux methods was carried out to separate instrumental effects from environmental effects and showed good agreement with a regression slope of 0.96 (r2 = 0.89. A period of abnormal downward atmospheric heat flux enhanced near-surface ocean stratification and reduced turbulent exchange, during which GF and EC transfer velocities showed good agreement but modelled COAREG values were significantly higher. The transfer velocity derived from near-surface ocean turbulence measurements on a spar buoy compared well with the COAREG model in general but showed less variation. This first direct comparison between EC and GF fluxes of DMS provides confidence in compilation of flux estimates from both techniques, as well as in the stable periods when the observations are not well predicted by the COAREG

  10. Gradient flux measurements of sea-air DMS transfer during the Surface Ocean Aerosol Production (SOAP) experiment

    Science.gov (United States)

    Smith, Murray J.; Walker, Carolyn F.; Bell, Thomas G.; Harvey, Mike J.; Saltzman, Eric S.; Law, Cliff S.

    2018-04-01

    Direct measurements of marine dimethylsulfide (DMS) fluxes are sparse, particularly in the Southern Ocean. The Surface Ocean Aerosol Production (SOAP) voyage in February-March 2012 examined the distribution and flux of DMS in a biologically active frontal system in the southwest Pacific Ocean. Three distinct phytoplankton blooms were studied with oceanic DMS concentrations as high as 25 nmol L-1. Measurements of DMS fluxes were made using two independent methods: the eddy covariance (EC) technique using atmospheric pressure chemical ionization-mass spectrometry (API-CIMS) and the gradient flux (GF) technique from an autonomous catamaran platform. Catamaran flux measurements are relatively unaffected by airflow distortion and are made close to the water surface, where gas gradients are largest. Flux measurements were complemented by near-surface hydrographic measurements to elucidate physical factors influencing DMS emission. Individual DMS fluxes derived by EC showed significant scatter and, at times, consistent departures from the Coupled Ocean-Atmosphere Response Experiment gas transfer algorithm (COAREG). A direct comparison between the two flux methods was carried out to separate instrumental effects from environmental effects and showed good agreement with a regression slope of 0.96 (r2 = 0.89). A period of abnormal downward atmospheric heat flux enhanced near-surface ocean stratification and reduced turbulent exchange, during which GF and EC transfer velocities showed good agreement but modelled COAREG values were significantly higher. The transfer velocity derived from near-surface ocean turbulence measurements on a spar buoy compared well with the COAREG model in general but showed less variation. This first direct comparison between EC and GF fluxes of DMS provides confidence in compilation of flux estimates from both techniques, as well as in the stable periods when the observations are not well predicted by the COAREG model.

  11. Are autistic traits measured equivalently in individuals with and without an autism spectrum disorder? An invariance analysis of the Autism Spectrum Quotient Short Form.

    Science.gov (United States)

    Murray, Aja L; Booth, Tom; McKenzie, Karen; Kuenssberg, Renate; O'Donnell, Michael

    2014-01-01

    It is common to administer measures of autistic traits to those without autism spectrum disorders (ASDs) with, for example, the aim of understanding autistic personality characteristics in non-autistic individuals. Little research has examined the extent to which measures of autistic traits actually measure the same traits in the same way across those with and without an ASD. We addressed this question using a multi-group confirmatory factor invariance analysis of the Autism Quotient Short Form (AQ-S: Hoekstra et al. in J Autism Dev Disord 41(5):589-596, 2011) across those with (n = 148) and without (n = 168) ASD. Metric variance (equality of factor loadings), but not scalar invariance (equality of thresholds), held suggesting that the AQ-S measures the same latent traits in both groups, but with a bias in the manner in which trait levels are estimated. We, therefore, argue that the AQ-S can be used to investigate possible causes and consequences of autistic traits in both groups separately, but caution is due when combining or comparing levels of autistic traits across the two groups.

  12. Measured and Predicted Variations in Fast Neutron Spectrum in Massive Shields of Water and Concrete

    Energy Technology Data Exchange (ETDEWEB)

    Aalto, E; Sandlin, R; Fraeki, R

    1965-09-15

    The absolute magnitude, and the variations in form, of the fast neutron spectrum during deep penetration (0.8 - 1.1 metre) in massive shields of water, ordinary and magnetite concrete have been studied by using threshold detectors (In (n, h'), S(n,p), Al(n, {alpha})). The results have been compared with predictions by two rigorous (NIOBE, Moments method) and two non-rigorous (multigroup removal-diffusion) shielding codes (NRN, RASH D). The absolute results predicted were in general within 50% of the measured ones, i. e. showed as good or better accuracy than thermal and epithermal flux predictions in the same small-reactor configurations. No difference in accuracy was found between the rigorous and non-rigorous methods. The changes in the relative form of the spectrum (indicated by variations in the (Al/S) and (In/S) reaction rate ratios and amounting to factors up to 3 - 4 during a one metre penetration in water) were rather accurately (within 10 - 30%) predicted by all of the methods. The photonuclear excitation of the 335 keV level used for detecting the In(n, n') reaction was found to distort completely the In results in water at penetrations > 50 cm.

  13. Advanced Measurement and Simulation Procedure for the Identification of Heat and Mass Transfer Parameters in Dynamic Adsorption Experiments

    Directory of Open Access Journals (Sweden)

    Andreas Velte

    2017-08-01

    Full Text Available Thermally-driven heat pumps can help to mitigate CO2 emissions by enhancing the efficiency of heating systems or by driving cooling systems with waste or solar heat. In order to make the thermally-driven systems more attractive for the end consumer, these systems need a higher power density. A higher power density can be achieved by intensifying the heat and mass transfer processes within the adsorption heat exchanger. For the optimization of this key component, a numerical model of the non-isothermal adsorption dynamics can be applied. The calibration of such a model can be difficult, since heat and mass transfer processes are strongly coupled. We present a measurement and simulation procedure that makes it possible to calibrate the heat transfer part of the numerical model separately from the mass transfer part. Furthermore, it is possible to identify the parts of the model that need to be improved. For this purpose, a modification of the well-known large temperature jump method is developed. The newly-introduced measurements are conducted under an inert N2 atmosphere, and the surface temperature of the sample is measured with an infrared sensor. We show that the procedure is applicable for two completely different types of samples: a loose grains configuration and a fibrous structure that is directly crystallized.

  14. Study of the effect of distance and misalignment between magnetically coupled coils for wireless power transfer in intraocular pressure measurement.

    Science.gov (United States)

    Rendon-Nava, Adrian E; Díaz-Méndez, J Alejandro; Nino-de-Rivera, Luis; Calleja-Arriaga, Wilfrido; Gil-Carrasco, Felix; Díaz-Alonso, Daniela

    2014-01-01

    An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  15. Study of the Effect of Distance and Misalignment between Magnetically Coupled Coils for Wireless Power Transfer in Intraocular Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Adrian E. Rendon-Nava

    2014-01-01

    Full Text Available An analysis of the effect of distance and alignment between two magnetically coupled coils for wireless power transfer in intraocular pressure measurement is presented. For measurement purposes, a system was fabricated consisting of an external device, which is a Maxwell-Wien bridge circuit variation, in charge of transferring energy to a biomedical implant and reading data from it. The biomedical implant is an RLC tank circuit, encapsulated by a polyimide coating. Power transfer was done by magnetic induction coupling method, by placing one of the inductors of the Maxwell-Wien bridge circuit and the inductor of the implant in close proximity. The Maxwell-Wien bridge circuit was biased with a 10 MHz sinusoidal signal. The analysis presented in this paper proves that wireless transmission of power for intraocular pressure measurement is feasible with the measurement system proposed. In order to have a proper inductive coupling link, special care must be taken when placing the two coils in proximity to avoid misalignment between them.

  16. Adjustment of the 235U Fission Spectrum

    International Nuclear Information System (INIS)

    GRIFFIN, PATRICK J.; WILLIAMS, J.G.

    1999-01-01

    The latest nuclear data are used to examine the sensitivity of the least squares adjustment of the 235 U fission spectrum to the measured reaction rates, dosimetry cross sections, and prior spectrum covariance matrix. All of these parameters were found to be very important in the spectrum adjustment. The most significant deficiency in the nuclear data is the absence of a good prior covariance matrix. Covariance matrices generated from analytic models of the fission spectra have been used in the past. This analysis reveals some unusual features in the covariance matrix produced with this approach. Specific needs are identified for improved nuclear data to better determine the 235 U spectrum. An improved 235 U covariance matrix and adjusted spectrum are recommended for use in radiation transport sensitivity analyses

  17. One-electron transfer reactions of the couple NAD./NADH

    International Nuclear Information System (INIS)

    Grodkowski, J.; Neta, P.; Carlson, B.W.; Miller, L.

    1983-01-01

    One-electron transfer reactions involving nicotinamide-adenine dinucleotide in its oxidized and reducd forms (NAD./NADH) were studied by pulse radiolysis in aqueous solutions. One-electron oxidation of NADH by various phenoxyl radicals and phenothiazine cation radicals was found to take place with rate constants in the range of 10 5 to 10 8 M -1 s -1 , depending on the redox potential of the oxidizing species. In all cases, NAD. is formed quantitatively with no indication for the existence of the protonated form (NADH + .). The spectrum of NAD., as well as the rates of oxidation of NADH by phenoxyl and by (chlorpromazine) + . were independent of pH between pH 4.5 and 13.5. Reaction of deuterated NADH indicated only a small kinetic isotope effect. All these findings point to an electron transfer mechanism. On the other hand, attempts to observe the reverse electron transfer, i.e., one-electron reduction of NAD. to NADH by radicals such as semiquinones, showed that k was less than 10 4 to 10 5 M -1 s -1 , so that it was unobservable. Consequently, it was not possible to achieve equilibrium conditions which would have permitted the direct measurement of the redox potential for NAD./NADH. One-electron reduction of NAD. appears to be an unlikely process. 1 table

  18. Studying electron transfer through alkanethiol self-assembled monolayers on a hanging mercury drop electrode using potentiometric measurements.

    Science.gov (United States)

    Cohen-Atiya, Meirav; Mandler, Daniel

    2006-10-14

    A new approach based on measuring the change of the open-circuit potential (OCP) of a hanging mercury drop electrode (HMDE), modified with alkanethiols of different chain length conducted in a solution containing a mixture of Ru(NH3)6(2+) and Ru(NH3)6(3+) is used for studying electron transfer across the monolayer. Following the time dependence of the OCP allowed the extraction of the kinetic parameters, such as the charge transfer resistance (R(ct)) and the electron transfer rate constant (k(et)), for different alkanethiol monolayers. An electron tunneling coefficient, beta, of 0.9 A(-1) was calculated for the monolayers on Hg.

  19. New radiative transfer models for obscuring tori in active galaxies

    NARCIS (Netherlands)

    van Bemmel, IM; Dullemond, CP

    Two-dimensional radiative transfer is employed to obtain the broad-band infrared spectrum of active galaxies. In the models we vary the geometry and size of the obscuring medium, the surface density, the opacity and the grain size distribution. Resulting spectral energy distributions are constructed

  20. Technology transfer by multinationals

    OpenAIRE

    Kostyantyn Zuzik

    2003-01-01

    The paper analyses the issue of technology transfer by multinational corporations. The following questions are explored: (a) world market of technologies, the role of MNCs (b) Choice of the technology transfer mode, Dunning's OLI-theory as a factor of the choice of the mode of transfer (c) measurement and profitability of technology transfer (d) transfer of technology through partnerships, JVs, alliances and through M&As (e) aspects of technology transfer by services multinationals. Paper uti...

  1. A principle for the noninvasive measurement of steady-state heat transfer parameters in living tissues

    Directory of Open Access Journals (Sweden)

    S. Yu. Makarov

    2014-01-01

    Full Text Available Measuring the parameters of biological tissues (include in vivo is of great importance for medical diagnostics. For example, the value of the blood perfusion parameter is associated with the state of the blood microcirculation system and its functioning affects the state of the tissues of almost all organs. This work describes a previously proposed principle [1] in generalized terms. The principle is intended for noninvasive measuring the parameters of stationary heat transfer in biological tissues. The results of some experiments (natural and numeric are also presented in the research.For noninvasive measurement of thermophysical parameters a number of techniques have been developed using non-stationary thermal process in biological tissue [2][3]. But these techniques require the collecting a lot of data to represent the time-dependent thermal signal. In addition, subsequent processing with specialized algorithms is required for optimal selecting the parameters. The goal of this research is to develop an alternative approach using stationary thermal process for non-invasive measuring the parameters of stationary heat transfer in living tissues.A general principle can be formulated for the measurement methods based on this approach. Namely, the variations (changes of two physical values are measured in the experiment at the transition from one thermal stationary state to another. One of these two physical values unambiguously determines the stationary thermal field into the biological tissue under specified experimental conditions while the other one is unambiguously determined through the thermal field. Then, the parameters can be found from the numerical (or analytical functional dependencies linking the measured variations because the dependencies contain unknown parameters.The dependencies are expressed in terms of the formula:dqi = fi({pj},Ui dUi,Here dqi is a variation of a physical value q which is unambiguously determined from the

  2. Measurement of a peak in the cosmic microwave background power spectrum from the North American test flight of Boomerang

    International Nuclear Information System (INIS)

    Mauskopf, P.D.; Ade, P.A.R.; Bock, J.J.; Borrill, J.; Boscaleri, A.; Crill, B.P.; Bernardis, P. de; DeGasperis, G.; De Troia, G.; Farese, P.; Ferreira, P.G.; Ganga, K.; Giacometti, M.; Hanany, S.; Hristov, V.V.; Iacoangeli, A.; Jaffe, A.H.; Lange, A.E.; Lee, A.T.; Masi, S.; Melchiorri, A.; Melchiorri, F.; Miglio, L.; Montroy, T.; Netterfield, C.B.; Pascale, E.; Piacentini, F.; Richards, P.L.; Romeo, G.; Ruhl, J.E.; Scannapieco, E.; Scaramuzzi, F.; Stompor, R.; Vittorio, N.

    1999-01-01

    We describe a measurement of the angular power spectrum of anisotrophies in the Cosmic Microwave Background (CMB) from 0.2 deg to approx. 10 deg. from the test flight of the BOOMERANG experiment. BOOMERANG is a balloon-borne telescope with a bolometric receiver designed to map CMB anisotrophies on a Long Duration Balloon flight. During a 6-hour test flight of a prototype system in 1997, we mapped > 200 square degrees at high galactic latitudes in two bands centered at 90 and 150 GHz with a resolution of 26 and 16.6 arcmin FWHM respectively. Analysis of the maps gives a power spectrum with a peak at angular scales of approx. 1 deg. with an amplitude of approx. 70-muKcmb

  3. A new algorithm combining geostatistics with the surrogate data approach to increase the accuracy of comparisons of point radiation measurements with cloud measurements

    Science.gov (United States)

    Venema, V. K. C.; Lindau, R.; Varnai, T.; Simmer, C.

    2009-04-01

    Two main groups of statistical methods used in the Earth sciences are geostatistics and stochastic modelling. Geostatistical methods, such as various kriging algorithms, aim at estimating the mean value for every point as well as possible. In case of sparse measurements, such fields have less variability at small scales and a narrower distribution as the true field. This can lead to biases if a nonlinear process is simulated on such a kriged field. Stochastic modelling aims at reproducing the structure of the data. One of the stochastic modelling methods, the so-called surrogate data approach, replicates the value distribution and power spectrum of a certain data set. However, while stochastic methods reproduce the statistical properties of the data, the location of the measurement is not considered. Because radiative transfer through clouds is a highly nonlinear process it is essential to model the distribution (e.g. of optical depth, extinction, liquid water content or liquid water path) accurately as well as the correlations in the cloud field because of horizontal photon transport. This explains the success of surrogate cloud fields for use in 3D radiative transfer studies. However, up to now we could only achieve good results for the radiative properties averaged over the field, but not for a radiation measurement located at a certain position. Therefore we have developed a new algorithm that combines the accuracy of stochastic (surrogate) modelling with the positioning capabilities of kriging. In this way, we can automatically profit from the large geostatistical literature and software. The algorithm is tested on cloud fields from large eddy simulations (LES). On these clouds a measurement is simulated. From the pseudo-measurement we estimated the distribution and power spectrum. Furthermore, the pseudo-measurement is kriged to a field the size of the final surrogate cloud. The distribution, spectrum and the kriged field are the inputs to the algorithm. This

  4. Geoelectrical Measurement of Multi-Scale Mass Transfer Parameters Final Report to the Subsurface Biogeochemical Research Program

    Energy Technology Data Exchange (ETDEWEB)

    Day-Lewis, Frederick; Singha, Kamini; Haggerty, Roy; Johnson, Timothy; Binley, Andrew; Lane, John

    2014-03-10

    . In this project, we sought to capitalize on the geophysical signatures of mass transfer. Previous numerical modeling and pilot-scale field experiments suggested that mass transfer produces a geoelectrical signature—a hysteretic relation between sampled (mobile-domain) fluid conductivity and bulk (mobile + immobile) conductivity—over a range of scales relevant to aquifer remediation. In this work, we investigated the geoelectrical signature of mass transfer during tracer transport in a series of controlled experiments to determine the operation of controlling parameters, and also investigated the use of complex-resistivity (CR) as a means of quantifying mass transfer parameters in situ without tracer experiments. In an add-on component to our grant, we additionally considered nuclear magnetic resonance (NMR) to help parse mobile from immobile porosities. Our study objectives were to: 1. Develop and demonstrate geophysical approaches to measure mass-transfer parameters spatially and over a range of scales, including the combination of electrical resistivity monitoring, tracer tests, complex resistivity, nuclear magnetic resonance, and materials characterization; and 2. Provide mass-transfer estimates for improved understanding of contaminant fate and transport at DOE sites, such as uranium transport at the Hanford 300 Area. To achieve our objectives, we implemented a 3-part research plan involving (1) development of computer codes and techniques to estimate mass-transfer parameters from time-lapse electrical data; (2) bench-scale experiments on synthetic materials and materials from cores from the Hanford 300 Area; and (3) field demonstration experiments at the DOE’s Hanford 300 Area.

  5. Bioluminescence resonance energy transfer system for measuring dynamic protein-protein interactions in bacteria.

    Science.gov (United States)

    Cui, Boyu; Wang, Yao; Song, Yunhong; Wang, Tietao; Li, Changfu; Wei, Yahong; Luo, Zhao-Qing; Shen, Xihui

    2014-05-20

    Protein-protein interactions are important for virtually every biological process, and a number of elegant approaches have been designed to detect and evaluate such interactions. However, few of these methods allow the detection of dynamic and real-time protein-protein interactions in bacteria. Here we describe a bioluminescence resonance energy transfer (BRET) system based on the bacterial luciferase LuxAB. We found that enhanced yellow fluorescent protein (eYFP) accepts the emission from LuxAB and emits yellow fluorescence. Importantly, BRET occurred when LuxAB and eYFP were fused, respectively, to the interacting protein pair FlgM and FliA. Furthermore, we observed sirolimus (i.e., rapamycin)-inducible interactions between FRB and FKBP12 and a dose-dependent abolishment of such interactions by FK506, the ligand of FKBP12. Using this system, we showed that osmotic stress or low pH efficiently induced multimerization of the regulatory protein OmpR and that the multimerization induced by low pH can be reversed by a neutralizing agent, further indicating the usefulness of this system in the measurement of dynamic interactions. This method can be adapted to analyze dynamic protein-protein interactions and the importance of such interactions in bacterial processes such as development and pathogenicity. Real-time measurement of protein-protein interactions in prokaryotes is highly desirable for determining the roles of protein complex in the development or virulence of bacteria, but methods that allow such measurement are not available. Here we describe the development of a bioluminescence resonance energy transfer (BRET) technology that meets this need. The use of endogenous excitation light in this strategy circumvents the requirement for the sophisticated instrument demanded by standard fluorescence resonance energy transfer (FRET). Furthermore, because the LuxAB substrate decanal is membrane permeable, the assay can be performed without lysing the bacterial cells

  6. Academic Technology Transfer: Tracking, Measuring and Enhancing Its Impact

    Science.gov (United States)

    Fraser, John

    2010-01-01

    Since the 1980 passage of the US Bayh-Dole Act, academic technology transfer has gained profile globally as a key component of knowledge-driven economic development. Research universities are seen as key contributors. In this article, focusing on the USA and drawing on over twenty years of experience in the field of academic technology transfer in…

  7. Partial decay energy of 51Cr from inner bremsstrahlung spectrum

    International Nuclear Information System (INIS)

    Sanjeeviah, H.; Sanjeevaiah, B.

    1980-01-01

    The inner bremsstrahlung spectrum accompanying orbital electron capture decay of 51 Cr to the first excited state in 51 V was measured in coincidence with 320 keV gamma rays. From the Jauch plot of the spectrum the partial decay energy was deduced to be 433 +- 18 keV in good agreement with the previously measured value and the accepted mass difference. The overall shape factor of the inner bremsstrahlung spectrum was found to be a constant X(1.1 +- 0.1). (author)

  8. A method of measurement of lifetimes of excited ion levels, using orientation transfer by Penning collisions

    International Nuclear Information System (INIS)

    Hamel, J.; Barrat, J.-P.

    1978-01-01

    A method for measuring the lifetimes of ionic excited levels is described. This method uses the transfer of coherence in a Penning collision using metastable optically oriented He 2 3 S 1 atoms. If R.F. transitions are induced in the (2 3 S 1 )He level, a transverse component of the magnetic moment of this level is created, which precesses coherently at the angular frequency ω of the R.F. field. The helium transverse orientation is partially transferred to the ions produced by Penning collisions. After the collision, the orientation transferred precesses around the external magnetic field at the Larmor frequency ω 0 ' of the ion excited level. The degree of orientation of the excited ion level depends, in the stationary state, on the average phase shift, during the lifetime tau prime of this level, between the Larmor precession at angular frequency ω 0 ' and the forced precession of helium (at angular frequency ω). The orientation of the ions is monitored by the modulation of the light emitted during their radiative decay. It is possible to determine the lifetime tau prime by measuring the degree of modulation of the reemitted light as a function of ω [fr

  9. The neutrino mass from beta spectrum (ITEP-85)

    International Nuclear Information System (INIS)

    Lubimov, V.

    1986-01-01

    The new cycle of tritium beta spectrum measurements in valine with the ITEP spectrometer is discussed (ITEP-85). The detailed investigation of the total response function (TRF) has been performed. The special run of beta spectrum measurements carried out in a wide energy interval (3.4 KeV) has turned out to be a sensitive mode for the TRF experimental test. The results confirm the indication of the neutrino nonzero mass. 11 refs., 10 figs

  10. The threshold photoelectron spectrum of mercury

    International Nuclear Information System (INIS)

    Rojas, H; Dawber, G; Gulley, N; King, G C; Bowring, N; Ward, R

    2013-01-01

    The threshold photoelectron spectrum of mercury has been recorded over the energy range (10–40 eV) which covers the region from the lowest state of the singly charged ion, 5d 10 6s( 2 S 1/2 ), to the double charged ionic state, 5d 9 ( 2 D 3/2 )6s( 1 D 2 ). Synchrotron radiation has been used in conjunction with the penetrating-field threshold-electron technique to obtain the spectrum with high resolution. The spectrum shows many more features than observed in previous photoemission measurements with many of these assigned to satellite states converging to the double ionization limit. (paper)

  11. Hyperfine spectrum measurement of an optically pumped far-infrared laser with a Michelson interferometer

    International Nuclear Information System (INIS)

    Zuo, Z G; Ling, F R; Wang, P; Liu, J S; Yao, J Q; Weng, C X

    2013-01-01

    In this letter, we present a Michelson interferometer for the hyperfine spectrum measurement of an optically pumped far-infrared laser with a highest frequency resolution of 3–5 GHz. CH 3 OH gas with a purity of 99.9%, is pumped by the CO 2 9P36 and 9R10 laser lines to generate terahertz lasers with frequencies of 2.52 and 3.11 THz, respectively. Moreover, except for the center frequency, which is in good agreement with theoretical work, some additional frequencies on both sides of the center frequency are obtained at a frequency interval of 0.15 THz. Meanwhile, the mechanism behind the observed experimental results is also investigated. (letter)

  12. Measurements of the power spectrum and dispersion relation of self-excited dust acoustic waves

    Science.gov (United States)

    Nosenko, V.; Zhdanov, S. K.; Kim, S.-H.; Heinrich, J.; Merlino, R. L.; Morfill, G. E.

    2009-12-01

    The spectrum of spontaneously excited dust acoustic waves was measured. The waves were observed with high temporal resolution using a fast video camera operating at 1000 frames per second. The experimental system was a suspension of micron-size kaolin particles in the anode region of a dc discharge in argon. Wave activity was found at frequencies as high as 450 Hz. At high wave numbers, the wave dispersion relation was acoustic-like (frequency proportional to wave number). At low wave numbers, the wave frequency did not tend to zero, but reached a cutoff frequency instead. The cutoff value declined with distance from the anode. We ascribe the observed cutoff to the particle confinement in this region.

  13. Correction Factor Analysis Of Foil Activation And The Effect Of Neglecting The Correction On Neutron Flux And Spectrum Measurement; ANALISIS FAKTOR KOREKSI KEPING AKTIVASI DAN PENGARUH PENGABAIANNYA PADA PENGUKURAN FLUKS DAN SPEKTRUM NEUTRON

    Energy Technology Data Exchange (ETDEWEB)

    Radiyanti, Ita Budi; Hamzah, Amir; Pinem, Surian [Multipurpose Reactor Centre Indonesia, Serpong, (Indonesia)

    1996-04-15

    Foil activation method is commonly used in flux and neutron spectrum measurement in nuclear reactor and other research. The effect of the thickness, type of foil material and neutron spectrum shape on the self shielding correction and activities correction on the edges of the foil have been analyzed. Also the effect of neglecting those correction factors on neutron flux and spectrum measurement were analyzed. The calculation of the correction factor has been done by using the program which had been verified for several foils. The foils used are Au, In. Cu, Co and Dy of 0.00254 cm -0.127 cm thickness and 1.27 cm diameter. The result showed that the correction factor foils were not similar due to the variation of activation cross section and neutron spectrum shape. For the neutron spectrum in RS-2 multi purpose reactor GAS using foils of 0.00254 cm thick. The effect of neglecting correction factor on thermal flux measurement for Au, In, Co and Cu were less than -6%, for Dy was about -25%. On epithermal flux measurement for Au and In were about -60%, Co and Dy was -12% and -6%, for Cu less than -2%. The effect of neglecting correction factor on spectrum measurement was the change on the neutron flux density values along neutron energy region.

  14. System and Method for Measuring the Transfer Function of a Guided Wave Device

    Science.gov (United States)

    Froggatt, Mark E. (Inventor); Erdogan, Turan (Inventor)

    2002-01-01

    A method/system are provided for measuring the NxN scalar transfer function elements for an N-port guided wave device. Optical energy of a selected wavelength is generated at a source and directed along N reference optical paths having N reference path lengths. Each reference optical path terminates in one of N detectors such that N reference signals are produced at the N detectors. The reference signals are indicative of amplitude, phase and frequency of the optical energy carried along the N reference optical paths. The optical energy from the source is also directed to the N-ports of the guided wave device and then on to each of the N detectors such that N measurement optical paths are defined between the source and each of the N detectors. A portion of the optical energy is modified in terms of at least one of the amplitude and phase to produce N modified signals at each of the N detectors. At each of the N detectors, each of the N modified signals is combined with a corresponding one of the N reference signals to produce corresponding N combined signals at each of the N detectors. A total of N(sup 2) measurement signals are generated by the N detectors. Each of the N(sup 2) measurement signals is sampled at a wave number increment (Delta)k so that N(sup 2) sampled signals are produced. The NxN transfer function elements are generated using the N(sup 2) sampled signals. Reference and measurement path length constraints are defined such that the N combined signals at each of the N detectors are spatially separated from one another in the time domain.

  15. Measurement of the energy spectrum of cosmic rays with the 26 station configuration of the IceTop detector

    International Nuclear Information System (INIS)

    Kislat, Fabian

    2011-01-01

    IceTop is an instrument at the geographic South Pole designed to detect cosmic ray air showers, particle cascades in the atmosphere initiated by high-energy cosmic rays. It is the surface component of the IceCube neutrino telescope. Since its completion in December 2010, IceTop consists of 81 detector stations covering an area of one square kilometer on the ice surface above IceCube. Each IceTop station consists of two ice-filled tanks in which the Cherenkov light emitted by charged air shower particles is measured. In this dissertation, an analysis of data taken in 2007 with 26 IceTop stations operational at that time is presented. First, properties of air showers like core position, direction and shower size were reconstructed from the measured signals. The core position can be determined to an accuracy of up to 6m and a direction resolution of up to 0.3 is achieved. The shower size is a measure of the energy of the primary particle and a resolution of up to 10% is achieved at high energies. In the next step the relation between primary energy and shower size, as well as resolution and efficiency are determined from Monte Carlo simulations of air showers and the IceTop detector. Here, an assumption was made about the chemical composition of cosmic rays. The informations obtained in these simulations are then used to unfold the spectrum of measured shower sizes in order to obtain the all-particle cosmic ray energy spectrum. This is done independently for particles from three different zenith angle intervals. The result of the unfolding depends on the assumed primary composition. Due to the isotropy of cosmic rays, results obtained in different zenith angle intervals must agree. While with the chosen analysis technique a simultaneous determination of primary particle mass and energy is limited due to systematic uncertainties, it has already been shown that the requirement of isotropy can be used to constrain the range of possible assumptions on the chemical

  16. Measurement of the energy spectrum of cosmic rays with the 26 station configuration of the IceTop detector

    Energy Technology Data Exchange (ETDEWEB)

    Kislat, Fabian

    2011-09-27

    IceTop is an instrument at the geographic South Pole designed to detect cosmic ray air showers, particle cascades in the atmosphere initiated by high-energy cosmic rays. It is the surface component of the IceCube neutrino telescope. Since its completion in December 2010, IceTop consists of 81 detector stations covering an area of one square kilometer on the ice surface above IceCube. Each IceTop station consists of two ice-filled tanks in which the Cherenkov light emitted by charged air shower particles is measured. In this dissertation, an analysis of data taken in 2007 with 26 IceTop stations operational at that time is presented. First, properties of air showers like core position, direction and shower size were reconstructed from the measured signals. The core position can be determined to an accuracy of up to 6m and a direction resolution of up to 0.3 is achieved. The shower size is a measure of the energy of the primary particle and a resolution of up to 10% is achieved at high energies. In the next step the relation between primary energy and shower size, as well as resolution and efficiency are determined from Monte Carlo simulations of air showers and the IceTop detector. Here, an assumption was made about the chemical composition of cosmic rays. The informations obtained in these simulations are then used to unfold the spectrum of measured shower sizes in order to obtain the all-particle cosmic ray energy spectrum. This is done independently for particles from three different zenith angle intervals. The result of the unfolding depends on the assumed primary composition. Due to the isotropy of cosmic rays, results obtained in different zenith angle intervals must agree. While with the chosen analysis technique a simultaneous determination of primary particle mass and energy is limited due to systematic uncertainties, it has already been shown that the requirement of isotropy can be used to constrain the range of possible assumptions on the chemical

  17. Measurement of turbulent spatial structure and kinetic energy spectrum by exact temporal-to-spatial mapping

    DEFF Research Database (Denmark)

    Buchhave, Preben; Velte, Clara Marika

    2017-01-01

    distortions caused by Taylor’s hypothesis. The method is first confirmed to produce the correct statistics using computer simulations and later applied to measurements in some of the most difficult regions of a round turbulent jet—the non-equilibrium developing region and the outermost parts of the developed......We present a method for converting a time record of turbulent velocity measured at a point in a flow to a spatial velocity record consisting of consecutive convection elements. The spatial record allows computation of dynamic statistical moments such as turbulent kinetic wavenumber spectra...... and spatial structure functions in a way that completely bypasses the need for Taylor’s hypothesis. The spatial statistics agree with the classical counterparts, such as the total kinetic energy spectrum, at least for spatial extents up to the Taylor microscale. The requirements for applying the method...

  18. Measurement of action forces and posture to determine the lumbar load of healthcare workers during care activities with patient transfers.

    Science.gov (United States)

    Theilmeier, Andreas; Jordan, Claus; Luttmann, Alwin; Jäger, Matthias

    2010-11-01

    Moving patients or other care activities with manual patient handling is characterized by high mechanical load on the lumbar spine of healthcare workers (HCWs). During the patient transfer activity, the caregivers exert lifting, pulling, and pushing forces varying over time with respect to amplitude and direction. Furthermore, the caregivers distinctly change their posture and frequently obtain postures asymmetrical to the median sagittal plane, including lateral bending and turning the trunk. This paper describes a procedure to determine lumbar load during patient transfer supported by measurement techniques and an exemplary application; this methodology represents the basis of a complex research project, the third 'Dortmund Lumbar Load Study (DOLLY 3)'. Lumbar load was determined by simulation calculations using a comprehensive biomechanical model ('The Dortmunder'). As the main influencing factors, the hand forces of the caregiver exerted during typical patient transfers and the posture and movements of the HCW were recorded in laboratory studies. The action forces were determined three-dimensionally with the help of a newly developed 'measuring bed', two different 'measuring chairs', a 'measuring bathtub', and a 'measuring floor'. To capture the forces during transfers in or at the bed, a common hospital bed was equipped with an additional framework, which is attached to the bedstead and connected to the bedspring frame via three-axial force sensors at the four corners. The other measuring systems were constructed similarly. Body movements were recorded using three-dimensional optoelectronic recording tools and video recordings. The posture and force data served as input data for the quantification of various lumbar-load indicators.

  19. Design of a nondestructive two-in-one instrument for measuring the polarization and energy spectrum at an X-ray FEL facility

    Science.gov (United States)

    Zhang, Qingmin; Deng, Bangjie; Chen, Yuanmiaoliang; Liu, Bochao; Chen, Shaofei; Fan, Jinquan; Feng, Lie; Deng, Haixiao; Liu, Bo; Wang, Dong

    2017-10-01

    The free electron laser (FEL), as a next-generation light source, is an attractive tool in scientific frontier research because of its advantages of full coherence, ultra-short pulse duration, and controllable polarization. Owing to the demand of real-time bunch diagnosis during FEL experiments, precise nondestructive measurements of the polarization and X-ray energy spectrum using one instrument are preferred. In this paper, such an instrument based on the electron time-of-flight technique is proposed. By considering the complexity and nonlinearity, a numerical model in the framework of Geant4 has been developed for optimization. Taking the Shanghai Soft X-ray FEL user facility as an example, its measurement performances' dependence on the critical parameters was studied systematically, and, finally, an optimal design was obtained, achieving resolutions of 0.5% for the polarization degree and 0.3 eV for the X-ray energy spectrum.

  20. Design, calibration and error analysis of instrumentation for heat transfer measurements in internal combustion engines

    Science.gov (United States)

    Ferguson, C. R.; Tree, D. R.; Dewitt, D. P.; Wahiduzzaman, S. A. H.

    1987-01-01

    The paper reports the methodology and uncertainty analyses of instrumentation for heat transfer measurements in internal combustion engines. Results are presented for determining the local wall heat flux in an internal combustion engine (using a surface thermocouple-type heat flux gage) and the apparent flame-temperature and soot volume fraction path length product in a diesel engine (using two-color pyrometry). It is shown that a surface thermocouple heat transfer gage suitably constructed and calibrated will have an accuracy of 5 to 10 percent. It is also shown that, when applying two-color pyrometry to measure the apparent flame temperature and soot volume fraction-path length, it is important to choose at least one of the two wavelengths to lie in the range of 1.3 to 2.3 micrometers. Carefully calibrated two-color pyrometer can ensure that random errors in the apparent flame temperature and in the soot volume fraction path length will remain small (within about 1 percent and 10-percent, respectively).

  1. Short range spread-spectrum radiolocation system and method

    Science.gov (United States)

    Smith, Stephen F.

    2003-04-29

    A short range radiolocation system and associated methods that allow the location of an item, such as equipment, containers, pallets, vehicles, or personnel, within a defined area. A small, battery powered, self-contained tag is provided to an item to be located. The tag includes a spread-spectrum transmitter that transmits a spread-spectrum code and identification information. A plurality of receivers positioned about the area receive signals from a transmitting tag. The position of the tag, and hence the item, is located by triangulation. The system employs three different ranging techniques for providing coarse, intermediate, and fine spatial position resolution. Coarse positioning information is provided by use of direct-sequence code phase transmitted as a spread-spectrum signal. Intermediate positioning information is provided by the use of a difference signal transmitted with the direct-sequence spread-spectrum code. Fine positioning information is provided by use of carrier phase measurements. An algorithm is employed to combine the three data sets to provide accurate location measurements.

  2. Evolution of the Turbulence Radial Wavenumber Spectrum near the L-H Transition in NSTX Ohmic Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, S.; Peebles, W.A., E-mail: skubota@ucla.edu [UCLA, Los Angeles (United States); Bush, C. E.; Maingi, R. [Oak Ridge National Laboratory, Oak Ridge (United States); Zweben, S. J.; Bell, R.; Crocker, N.; Diallo, A.; Kaye, S.; LeBlanc, B. P.; Park, J. K.; Ren, Y. [Princeton Plasma Physics Laboratory, Princeton University, Princeton (United States); Maqueda, R. J. [Nova Photonics, Princeton (United States); Raman, R. [University of Washington, Seattle (United States)

    2012-09-15

    Full text: The measurement of radially extended meso-scale structures such as zonal flows and streamers, as well as the underlying microinstabilities driving them, is critical for understanding turbulence-driven transport in plasma devices. In particular, the shape and evolution of the radial wavenumber spectrum indicate details of the nonlinear spectral energy transfer, the spreading of turbulence, as well as the formation of transport barriers. In the National Spherical Torus Experiment (NSTX), the FMCW backscattering diagnostic is used to probe the turbulence radial wavenumber spectrum (k{sub r} = 0 - 22 cm-1 ) across the outboard minor radius near the L- to H-mode transition in Ohmic discharges. During the L-mode phase, a broad spectral component (k{sub r} {approx} 2 - 10 cm{sup -1} ) extends over a significant portion of the edge-core from R = 120 to 155 cm ({rho} = 0.4 - 0.95). At the L-H transition, turbulence is quenched across the measurable k{sub r} range at the ETB location, where the radial correlation length drops from {approx} 1.5 - 0.5 cm. The k{sub r} spectrum away from the ETB location is modified on a time scale of tens of microseconds, indicating that nonlocal turbulence dynamics are playing a strong role. Close to the L-H transition, oscillations in the density gradient and edge turbulence quenching become highly correlated. These oscillations are also present in Ohmic discharges without an L-H transition, but are far less frequent. Similar behavior is also seen near the L-H transition in NB-heated discharges. (author)

  3. Concentration and measuring Platinum Group Elements (PGE) Transfer Factor in soil and vegetations

    International Nuclear Information System (INIS)

    Adibah Sakinah Oyub

    2012-01-01

    This study was conducted to determine the concentration and to measure platinum group elements (PGE) transfer factor in environmental samples of roadside soil and vegetation. The use of vehicle catalytic converter has released platinum group elements (PGE) and other gases into the environment. Thus, roadside soil and plants were exposed to this element and has become the medium for the movement of this elements. Samples of roadside soil and vegetation were taken at various locations in UKM Bangi Toll and the concentration of platinum group elements (PGE) is determined using mass spectrometry-inductively coupled plasma (ICP-MS). Overall, the concentrations of platinum group elements (PGE), which is the element platinum (Pt) in soil was 0.016 ± 0.036 μgg -1 . While the concentration of the elements palladium (Pd) was 0.079 ± 0.019 μgg -1 and element rhodium (Rh) is at a concentration of 0.013 ± 0.020 μgg -1 . Overall, the transfer factor for the element platinum (Pt) is 1. While the transfer factor of the element palladium (Pd) is 0.96 and the element rhodium (Rh) is 1.11. In conclusion, the concentration of platinum group elements (PGE) in soils have increased. (author)

  4. Theory of lidar method for measurement of the modulation transfer function of water layers.

    Science.gov (United States)

    Dolin, Lev S

    2013-01-10

    We develop a method to evaluate the modulation transfer function (MTF) of a water layer from the characteristics of lidar signal backscattered by water volume. We propose several designs of a lidar system for remote measurement of the MTF and the procedure to determine optical properties of water using the measured MTF. We discuss a laser system for sea-bottom imaging that accounts for the influence of water slab on the image structure and allows for correction of image distortions caused by light scattering in water. © 2013 Optical Society of America

  5. Development of an apparatus to measure thermophysical properties of wind tunnel heat transfer models

    Science.gov (United States)

    Romanowski, R. F.; Steinberg, I. H.

    1974-01-01

    The apparatus and technique for measuring the thermophysical properties of models used with the phase-change paint method for obtaining wind tunnel heat transfer data are described. The method allows rapid measurement of the combined properties in a transient manner similar to an actual wind tunnel test. An effective value of the thermophysical properties can be determined which accounts for changes in thermal properties with temperature or with depth into the model surface. The apparatus was successfully tested at various heating rates between 19,000 and 124,000 watts per square meter.

  6. Background Adjusted Alignment-Free Dissimilarity Measures Improve the Detection of Horizontal Gene Transfer

    Directory of Open Access Journals (Sweden)

    Kujin Tang

    2018-04-01

    Full Text Available Horizontal gene transfer (HGT plays an important role in the evolution of microbial organisms including bacteria. Alignment-free methods based on single genome compositional information have been used to detect HGT. Currently, Manhattan and Euclidean distances based on tetranucleotide frequencies are the most commonly used alignment-free dissimilarity measures to detect HGT. By testing on simulated bacterial sequences and real data sets with known horizontal transferred genomic regions, we found that more advanced alignment-free dissimilarity measures such as CVTree and d2* that take into account the background Markov sequences can solve HGT detection problems with significantly improved performance. We also studied the influence of different factors such as evolutionary distance between host and donor sequences, size of sliding window, and host genome composition on the performances of alignment-free methods to detect HGT. Our study showed that alignment-free methods can predict HGT accurately when host and donor genomes are in different order levels. Among all methods, CVTree with word length of 3, d2* with word length 3, Markov order 1 and d2* with word length 4, Markov order 1 outperform others in terms of their highest F1-score and their robustness under the influence of different factors.

  7. Measurement of the cosmic microwave background spectrum by the COBE FIRAS instrument

    Science.gov (United States)

    Mather, J. C.; Cheng, E. S.; Cottingham, D. A.; Eplee, R. E., Jr.; Fixsen, D. J.; Hewagama, T.; Isaacman, R. B.; Jensen, K. A.; Meyer, S. S.; Noerdlinger, P. D.

    1994-01-01

    The cosmic microwave background radiation (CMBR) has a blackbody spectrum within 3.4 x 10(exp -8) ergs/sq cm/s/sr cm over the frequency range from 2 to 20/cm (5-0.5 mm). These measurements, derived from the Far-Infrared Absolute Spectrophotomer (FIRAS) instrument on the Cosmic Background Explorer (COBE) satellite, imply stringent limits on energy release in the early universe after t approximately 1 year and redshift z approximately 3 x 10(exp 6). The deviations are less than 0.30% of the peak brightness, with an rms value of 0.01%, and the dimensionless cosmological distortion parameters are limited to the absolute value of y is less than 2.5 x 10(exp -5) and the absolute value of mu is less than 3.3 x 10(exp -4) (95% confidence level). The temperature of the CMBR is 2.726 +/- 0.010 K (95% confidence level systematic).

  8. Transfer standard for the spectral density of relative intensity noise of optical fiber sources near 1550 nm

    Energy Technology Data Exchange (ETDEWEB)

    Obarski, Gregory E.; Splett, Jolene D.

    2001-06-01

    We have developed a transfer standard for the spectral density of relative intensity noise (RIN) of optical fiber sources near 1550 nm. Amplified spontaneous emission (ASE) from an erbium-doped fiber amplifier (EDFA), when it is optically filtered over a narrow band ({lt}5 nm), yields a stable RIN spectrum that is practically constant to several tens of gigahertz. The RIN is calculated from the power spectral density as measured with a calibrated optical spectrum analyzer. For a typical device it is {minus}110 dB/Hz, with uncertainty {le}0.12 dB/Hz. The invariance of the RIN under attenuation yields a considerable dynamic range with respect to rf noise levels. Results are compared with those from a second method that uses a distributed-feedback laser (DFB) that has a Poisson-limited RIN. Application of each method to the same RIN measurement system yields frequency-dependent calibration functions that, when they are averaged, differ by {le}0.2 dB. {copyright} 2001 Optical Society of America

  9. Defining a methodology for benchmarking spectrum unfolding codes

    International Nuclear Information System (INIS)

    Meyer, W.; Kirmser, P.G.; Miller, W.H.; Hu, K.K.

    1976-01-01

    It has long been recognized that different neutron spectrum unfolding codes will produce significantly different results when unfolding the same measured data. In reviewing the results of such analyses it has been difficult to determine which result if any is the best representation of what was measured by the spectrometer detector. A proposal to develop a benchmarking procedure for spectrum unfolding codes is presented. The objective of the procedure will be to begin to develop a methodology and a set of data with a well established and documented result that could be used to benchmark and standardize the various unfolding methods and codes. It is further recognized that development of such a benchmark must involve a consensus of the technical community interested in neutron spectrum unfolding

  10. Measurement of the internal bremsstrahlung spectrum of a 89Sr beta emitter in the 1–100 keV photon energy regime

    International Nuclear Information System (INIS)

    Singh, Amrit; Dhaliwal, A.S.

    2015-01-01

    The internal bremsstrahlung (IB) spectrum of 89 Sr, which is a unique first forbidden beta emitter, is studied in the 1–100 keV photon energy regime. The IB spectrum is experimentally measured using a Si(Li) detector, which is efficient in this photon energy regime, and is compared with the IB distributions that are predicted by the Knipp, Uhlenbeck and Bloch (KUB), Nilsson, and Lewis and Ford theories. In the soft energy regime up to 15 keV, the measured results are in agreement with all the aforementioned theories. However, from 16–30 keV, the experimental results are in agreement with the Lewis and Ford theory, which applies to forbidden transitions, and at higher photon energies, the Nilsson theory best describes the measured results. The differences among the different theories also increase with the photon energy. The effect of the electrostatic Coulomb field on the IB process for beta emitters with different end-point energies is investigated by comparing the ratio of the IB probabilities predicted using the KUB and Nilsson theories for 35 S and 89 Sr, i.e., soft and hard beta emitters, respectively. The Coulomb effect is shown to be significant in the high photon energy regime and for beta emitters with low end-point energies. - Highlights: • Internal bremsstrahlung spectrum of 89 Sr, a unique first forbidden beta emitter, is studied. • The measurements are taken in the photon energy regions of 1–100 keV with Si(Li) detector. • The measured results are deviating from Lewis and Ford theory and are close to the Nilsson theory. • The effect of Coulomb field on the IB process for different end point energy sources is investigated. • Effect of Coulomb field is more for low energy beta emitter towards the high energy end

  11. Passive vs Active Knowledge Transfer: boosting grant proposal impact

    Science.gov (United States)

    Grigorov, Ivo; Bayliss-Brown, Georgia; Murphy, David; Thøgersen, Thomas; Mariani, Patrizio

    2017-04-01

    Research funders are increasingly concerned with measurable socio-economic impact of investment in research, and on increasingly shorter timescales. Innovation, and "open innovation" are the policy priorities of the moment and optimising the flow of ideas along the lab-2-market spectrum is essential for re-use of results, fuelling open innovation, and boosting socio-economic impact or public funded research. The presentation showcases two complimentary strategies that Project Managers can employ pre- and/or post-award in order to optimise the exploitation and impact of research project: passive and active knowledge transfer. Passive Knowledge Transfer relies on maximum disclosure of research output (other than commercially exploitable research via patents and other IPR) in the interest of optimal reproducibility, independent validation and re-use by both academic and non-academic users, without necessarily targeting specific users. Tools of the trade include standard public & academic dissemination means (research articles, online media publications, newsletters, generic policy briefs). Additional transparency of the research workflow can be achieved by integrating "open science" (open notebooks, open data, open research software and open access to research publications) as well as Virtual Research Environments (VREs) in the methodology of the proposed work. Ensuring that the proposal partners are suitably trained in best practices of open science, makes proposal grant more competitive at evaluation and the resulting maximum access to research outputs does contribute to better return on investment for funders (Beagrie 2016) and economic growth objectives of public s e.g. Blue Growth (Houghton & Swan 2011, Marine Knowledge 2020 Roadmap). Active Knowledge Transfer, or the pro-active translation of research into policy or commercial context, is the more classical and better known approach (also referred to as extension services, or researchers providing advice e.g. to

  12. The double beta decay spectrum of 100Mo as measured with a TPC

    International Nuclear Information System (INIS)

    Elliott, S.R.; Moe, M.K.; Nelson, M.A.; Vient, M.A.

    1991-01-01

    A time projection chamber with 8.3 grams of enriched 100 MoO 3 as the central electrode has been operating approximately five months in an underground laboratory. A preliminary analysis of the two-electron sum energy spectrum, the spectrum of those same electrons taken singly, and the opening angle distribution yields a half life of 1.16 -0.08 +0.34 x10 19 y at the 68% confidence level for two-neutrino double beta decay of 100 Mo. (author)

  13. Scaling CMS data transfer system for LHC start-up

    International Nuclear Information System (INIS)

    Tuura, L; Bockelman, B; Bonacorsi, D; Egeland, R; Feichtinger, D; Metson, S; Rehn, J

    2008-01-01

    The CMS experiment will need to sustain uninterrupted high reliability, high throughput and very diverse data transfer activities as the LHC operations start. PhEDEx, the CMS data transfer system, will be responsible for the full range of the transfer needs of the experiment. Covering the entire spectrum is a demanding task: from the critical high-throughput transfers between CERN and the Tier-1 centres, to high-scale production transfers among the Tier-1 and Tier-2 centres, to managing the 24/7 transfers among all the 170 institutions in CMS and to providing straightforward access to handful of files to individual physicists. In order to produce the system with confirmed capability to meet the objectives, the PhEDEx data transfer system has undergone rigourous development and numerous demanding scale tests. We have sustained production transfers exceeding 1 PB/month for several months and have demonstrated core system capacity several orders of magnitude above expected LHC levels. We describe the level of scalability reached, and how we got there, with focus on the main insights into developing a robust, lock-free and scalable distributed database application, the validation stress test methods we have used, and the development and testing tools we found practically useful

  14. Demonstration of Improved Charge Transfer in Graphene/Au Nanorods Plasmonic Hybrids Stabilized by Benzyl Thiol Linkers

    Directory of Open Access Journals (Sweden)

    Giuseppe Valerio Bianco

    2016-01-01

    Full Text Available Hybrids based on graphene decorated with plasmonic gold (Au nanostructures are being investigated as possible materials combination to add to graphene functionalities of tunable plasmon resonance and enhanced absorption at selected wavelength in the visible-near-infrared region of the spectrum. Here, we report a solution drop-casting approach for fabricating stable hybrids based on chemical vapor deposition (CVD graphene and Au nanorods, which are able to activate effective charge transfer from graphene. We demonstrate that CVD graphene functionalization by benzyl thiol (BZT provides the linker to strong anchoring, via S-Au bonds, Au nanorods to graphene. Optical measurements by spectroscopic ellipsometry give evidence of the introduction of plasmon resonances at 1.85 and 2.25 eV in the Au nanorods/BZT/graphene hybrids, which enable surface enhanced Raman scattering (SERS detection. Furthermore, an effective electron transfer from graphene to Au nanorods, resulting in an enhancement of p-type doping of graphene with a consequent decrease of its sheet resistance, is probed by Raman spectroscopy and corroborated by electrical measurements.

  15. Energy transfer mechanism in CsI:Eu crystal

    International Nuclear Information System (INIS)

    Yakovlev, V.; Trefilova, L.; Karnaukhova, A.; Ovcharenko, N.

    2014-01-01

    This paper studies the scintillation process in CsI:Eu crystal exposed to the pulse electron irradiation (E=0.25 MeV, t 1/2 =15 ns and W=0.003 J/cm 2 ). It has been proved that the energy transfer from the lattice to Eu 2+ ions in CsI:Eu occurs through the re-absorption of STE emission. The proposed model rests on the following experimental facts: (1) the activator emission at 2.68 eV rises gradually after the decay of the excitation pulse even at temperature lower than 90 K when V k centers are immobile; (2) the rise time of 2.68 eV emission and the decay time of STE emission have the same temperature dependences at T=78–300 K; (3) the excitation spectrum of 2.68 eV emission overlaps the emission spectrum of STE. -- Highlights: • The scintillation process in CsI:Eu was studied under pulsed electron irradiation. • A model of the energy transfer from the lattice to Eu 2+ ions in CsI:Eu was proposed. • Eu 2+ ions in CsI:Eu reabsorb the π-emission of self-trapped excitons

  16. Wind speed power spectrum analysis for Bushland, Texas

    Energy Technology Data Exchange (ETDEWEB)

    Eggleston, E.D. [USDA-Agricultural Research Service, Bushland, TX (United States)

    1996-12-31

    Numerous papers and publications on wind turbulence have referenced the wind speed spectrum presented by Isaac Van der Hoven in his article entitled Power Spectrum of Horizontal Wind Speed Spectrum in the Frequency Range from 0.0007 to 900 Cycles per Hour. Van der Hoven used data measured at different heights between 91 and 125 meters above the ground, and represented the high frequency end of the spectrum with data from the peak hour of hurricane Connie. These facts suggest we should question the use of his power spectrum in the wind industry. During the USDA - Agricultural Research Service`s investigation of wind/diesel system power storage, using the appropriate wind speed power spectrum became a significant issue. We developed a power spectrum from 13 years of hourly average data, 1 year of 5 minute average data, and 2 particularly gusty day`s 1 second average data all collected at a height of 10 meters. While the general shape is similar to the Van der Hoven spectrum, few of his peaks were found in the Bushland spectrum. While higher average wind speeds tend to suggest higher amplitudes in the high frequency end of the spectrum, this is not always true. Also, the high frequency end of the spectrum is not accurately described by simple wind statistics such as standard deviation and turbulence intensity. 2 refs., 5 figs., 1 tab.

  17. Directional spectrum of ocean waves

    Digital Repository Service at National Institute of Oceanography (India)

    Fernandes, A.A; Gouveia, A; Nagarajan, R.

    This paper describes a methodology for obtaining the directional spectrum of ocean waves from time series measurement of wave elevation at several gauges arranged in linear or polygonal arrays. Results of simulated studies using sinusoidal wave...

  18. Measurement of π-p→π0n at large momentum transfer

    International Nuclear Information System (INIS)

    Apel, W.D.; Augenstein, K.H.; Krueger, M.; Mueller, H.; Schneider, H.; Sigurdsson, G.; Bertolucci, E.; Mannelli, I.; Pierazzini, G.M.; Quaglia, M.; Scribano, A.; Sergiampetri, F.; Vincelli, M.L.; Donskov, S.V.; Inyakin, A.V.; Kachanov, V.A.; Krasnokutsky, R.N.; Mikhailov, Yu.V.; Prokoshkin, Yu.D.; Shuvalov, R.S.; Toropin, A.N.; Leder, G.

    1977-01-01

    New results on a high statistics measurement of pion-nucleon charge exchange scattering at 40 GeV/c, extending in momentum transfer up to -t = 1.8 (GeV/c) 2 , are reported and compared with an optical impact parameter model, together with previous data for the reaction π - p→etan at the same energy. The imaginary part of the pole trajectory b 0 (s) is determined from the slope of the tangent to the maxima of (-t)sup(1/2) dsigma/dt. The linear increase of Im b 0 (s) with log s, which has been observed at low energies, continues up to 40 GeV/c. (Auth.)

  19. The Atacama Cosmology Telescope: A Measurement of the 600 less than l less than 8000 Cosmic Microwave Background Power Spectrum at 148 GHz

    Science.gov (United States)

    Fowler, J. W.; Acquaviva, V.; Ade, P. A. R.; Aguirre, P.; Amiri, M.; Appel, J. W.; Barrientos, L. F.; Bassistelli, E. S.; Bond, J. R.; Brown, B.; hide

    2010-01-01

    We present a measurement of the angular power spectrum of the cosmic microwave background (CMB) radiation observed at 148 GHz. The measurement uses maps with 1.4' angular resolution made with data from the Atacama Cosmology Telescope (ACT). The observations cover 228 deg(sup 2) of the southern sky, in a 4 deg. 2-wide strip centered on declination 53 deg. South. The CMB at arc minute angular scales is particularly sensitive to the Silk damping scale, to the Sunyaev-Zel'dovich (SZ) effect from galaxy dusters, and to emission by radio sources and dusty galaxies. After masking the 108 brightest point sources in our maps, we estimate the power spectrum between 600 less than l less than 8000 using the adaptive multi-taper method to minimize spectral leakage and maximize use of the full data set. Our absolute calibration is based on observations of Uranus. To verify the calibration and test the fidelity of our map at large angular scales, we cross-correlate the ACT map to the WMAP map and recover the WMAP power spectrum from 250 less than l less than 1150. The power beyond the Silk damping tail of the CMB (l approximately 5000) is consistent with models of the emission from point sources. We quantify the contribution of SZ clusters to the power spectrum by fitting to a model normalized to sigma 8 = 0.8. We constrain the model's amplitude A(sub sz) less than 1.63 (95% CL). If interpreted as a measurement of as, this implies sigma (sup SZ) (sub 8) less than 0.86 (95% CL) given our SZ model. A fit of ACT and WMAP five-year data jointly to a 6-parameter ACDM model plus point sources and the SZ effect is consistent with these results.

  20. Use of a laser-induced fluorescence thermal imaging system for film cooling heat transfer measurement

    Energy Technology Data Exchange (ETDEWEB)

    Chyu, M.K. [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    1995-10-01

    This paper describes a novel approach based on fluorescence imaging of thermographic phosphor that enables the simultaneous determination of both local film effectiveness and local heat transfer on a film-cooled surface. The film cooling model demonstrated consists of a single row of three discrete holes on a flat plate. The transient temperature measurement relies on the temperature-sensitive fluorescent properties of europium-doped lanthanum oxysulfide (La{sub 2}O{sub 2}S:EU{sup 3+}) thermographic phosphor. A series of full-field surface temperatures, mainstream temperatures, and coolant film temperatures were acquired during the heating of a test surface. These temperatures are used to calculate the heat transfer coefficients and the film effectiveness simultaneously. Because of the superior spatial resolution capability for the heat transfer data reduced from these temperature frames, the laser-induced fluorescence (LIF) imaging system, the present study observes the detailed heat transfer characteristics over a film-protected surface. The trend of the results agrees with those obtained using other conventional thermal methods, as well as the liquid crystal imaging technique. One major advantage of this technique is the capability to record a large number of temperature frames over a given testing period. This offers multiple-sample consistency.

  1. Fission Product Data Measured at Los Alamos for Fission Spectrum and Thermal Neutrons on 239Pu, 235U, 238U

    International Nuclear Information System (INIS)

    Selby, H.D.; Mac Innes, M.R.; Barr, D.W.; Keksis, A.L.; Meade, R.A.; Burns, C.J.; Chadwick, M.B.; Wallstrom, T.C.

    2010-01-01

    We describe measurements of fission product data at Los Alamos that are important for determining the number of fissions that have occurred when neutrons are incident on plutonium and uranium isotopes. The fission-spectrum measurements were made using a fission chamber designed by the National Institute for Standards and Technology (NIST) in the BIG TEN critical assembly, as part of the Inter-laboratory Liquid Metal Fast Breeder Reactor (LMFBR) Reaction Rate (ILRR) collaboration. The thermal measurements were made at Los Alamos' Omega West Reactor. A related set of measurements were made of fission-product ratios (so-called R-values) in neutron environments provided by a number of Los Alamos critical assemblies that range from having average energies causing fission of 400-600 keV (BIG TEN and the outer regions of the Flattop-25 assembly) to higher energies (1.4-1.9 MeV) in the Jezebel, and in the central regions of the Flattop-25 and Flattop-Pu, critical assemblies. From these data we determine ratios of fission product yields in different fuel and neutron environments (Q-values) and fission product yields in fission spectrum neutron environments for 99 Mo, 95 Zr, 137 Cs, 140 Ba, 141,143 Ce, and 147 Nd. Modest incident-energy dependence exists for the 147 Nd fission product yield; this is discussed in the context of models for fission that include thermal and dynamical effects. The fission product data agree with measurements by Maeck and other authors using mass-spectrometry methods, and with the ILRR collaboration results that used gamma spectroscopy for quantifying fission products. We note that the measurements also contradict earlier 1950s historical Los Alamos estimates by ∼5-7%, most likely owing to self-shielding corrections not made in the early thermal measurements. Our experimental results provide a confirmation of the England-Rider ENDF/B-VI evaluated fission-spectrum fission product yields that were carried over to the ENDF/B-VII.0 library, except

  2. Theoretical determination of spectrum-exposure rate conversion operator of HPGe detector and its application to the measurement of environmental gamma-ray exposure rate

    International Nuclear Information System (INIS)

    Park, Ch.M.; Choi, B.I.; Kwak, S.S.; Ji, P.K.; Kim, T.W.; Park, Y.W.; Yoon, B.K.

    1993-01-01

    A conversion operator between spectrum and exposure rate, using a portable HPGe detector for environmental radiation monitoring, was determined theoretically under the assumption of uniform distribution of radiation source on the ground surface. The measurement results were compared with those of a pressurized ionization chamber. The results obtained with the HPGe detector were slightly lower. The method can be easily applied to any gamma ray detector to obtain a spectrum - exposure-rate conversion factor for computing the exposure rate of environmental gamma radiation. (N.T.) 15 refs.; 6 figs.; 3 tabs

  3. Refinements in the Los Alamos model of the prompt fission neutron spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Madland, D.G., E-mail: dgm@lanl.gov; Kahler, A.C.

    2017-01-15

    This paper presents a number of refinements to the original Los Alamos model of the prompt fission neutron spectrum and average prompt neutron multiplicity as derived in 1982. The four refinements are due to new measurements of the spectrum and related fission observables many of which were not available in 1982. They are also due to a number of detailed studies and comparisons of the model with previous and present experimental results including not only the differential spectrum, but also integral cross sections measured in the field of the differential spectrum. The four refinements are (a) separate neutron contributions in binary fission, (b) departure from statistical equilibrium at scission, (c) fission-fragment nuclear level-density models, and (d) center-of-mass anisotropy. With these refinements, for the first time, good agreement has been obtained for both differential and integral measurements using the same Los Alamos model spectrum.

  4. Determination of the heat transfer coefficient from IRT measurement data using the Trefftz method

    Directory of Open Access Journals (Sweden)

    Maciejewska Beata

    2016-01-01

    Full Text Available The paper presents the method of heat transfer coefficient determination for boiling research during FC-72 flow in the minichannels, each 1.7 mm deep, 24 mm wide and 360 mm long. The heating element was the thin foil, enhanced on the side which comes into contact with fluid in the minichannels. Local values of the heat transfer coefficient were calculated from the Robin boundary condition. The foil temperature distribution and the derivative of the foil temperature were obtained by solving the two-dimensional inverse heat conduction problem, due to measurements obtained by IRT. Calculations was carried out by the method based on the approximation of the solution of the problem using a linear combination of Trefftz functions. The basic property of this functions is they satisfy the governing equation. Unknown coefficients of linear combination of Trefftz functions are calculated from the minimization of the functional that expresses the mean square error of the approximate solution on the boundary. The results presented as IR thermographs, two-phase flow structure images and the heat transfer coefficient as a function of the distance from the channel inlet, were analyzed.

  5. The Effect of Pivotal Response Treatment in Children with Autism Spectrum Disorders: A Non-randomized Study with a Blinded Outcome Measure

    NARCIS (Netherlands)

    Duifhuis, E.A.; Boer, J.C. den; Doornbos, A.; Buitelaar, J.K.; Oosterling, I.J.; Klip, H.

    2017-01-01

    Purpose of this quasi-experimental trial was to investigate the effect of Pivotal response treatment (PRT) versus treatment as usual (TAU) on autism symptoms. Children with autism spectrum disorder (ASD), aged 3-8 years, received either PRT (n = 11) or TAU (n = 13). Primary outcome measure was the

  6. Measurement of the cosmic ray muon spectrum and charge ratio in the atmosphere from ground level to balloon altitudes

    Energy Technology Data Exchange (ETDEWEB)

    Basini, G.; Bongiorno, F. [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Bellotti, R.; Cafagna, F.; Circella, M.; De Cataldo, G.; De Marzo, C.N. [Bari Univ. (Italy)]|[INFN, Bari (Italy); Brunetti, M.T.; Codini, A. [Perugia Univ. (Italy)]|[INFN, Perugia (Italy); De Pascale, M.P. [Rome Univ. `Tor Vergata` (Italy)]|[INFN, Rome (Italy)

    1995-09-01

    A measurement of the cosmic ray muon flux in the atmosphere has been carried out from the data collected by the MASS2 (Matter Antimatter Spectrometer System) apparatus during the ascent of the 1991 flight. The experiment was performed on September 23, 1991 from Fort Sumner, New Mexico (USA) at a geomagnetic cutoff of about 4.5 GV/c. The negative muon spectrum has been determined in different depth ranges in the momentum interval 0.33-40 GeV/c with higher statistics and better background rejection than reported before. Taking advantage of the high geomagnetic cutoff and of the high performances of the instrument, the positive muon spectrum has also been determined and the altitude dependence of the muon charge ratio has been investigated in the 0.33-1.5 GeV/c momentum range.

  7. Cross-spectrum symbol synchronization

    Science.gov (United States)

    Mccallister, R. D.; Simon, M. K.

    1981-01-01

    A popular method of symbol synchronization exploits one aspect of generalized harmonic analysis, normally referred to as the cross-spectrum. Utilizing nonlinear techniques, the input symbol energy is effectively concentrated onto multiples of the symbol clock frequency, facilitating application of conventional phase lock synchronization techniques. A general treatment of the cross-spectrum technique is developed and shown to be applicable across a broad class of symbol modulation formats. An important specific symbol synchronization application is then treated, focusing the general development to provide both insight and quantitative measure of the performance impact associated with variation in these key synchronization parameters: symbol modulation format, symbol transition probability, symbol energy to noise density ratio, and symbol rate to filter bandwidth ratio.

  8. Elastic scattering and quasi-elastic transfers

    International Nuclear Information System (INIS)

    Mermaz, M.C.

    1978-01-01

    Experiments are presented which it will be possible to carry out at GANIL on the elastic scattering of heavy ions: diffraction phenomena if the absorption is great, refraction phenomena if absorption is low. The determination of the optical parameters can be performed. The study of the quasi-elastic transfer reactions will make it possible to know the dynamics of the nuclear reactions, form exotic nuclei and study their energy excitation spectrum, and analyse the scattering and reaction cross sections [fr

  9. Pump--probe measurements of state-to-state rotational energy transfer rates in N2 (v=1)

    International Nuclear Information System (INIS)

    Sitz, G.O.; Farrow, R.L.

    1990-01-01

    We report direct measurements of the state-to-state rotational energy transfer rates for N 2 (υ=1) at 298 K. Stimulated Raman pumping of Q-branch (υ=1 left-arrow 0) transitions is used to prepare a selected rotational state of N 2 in the υ=1 state. After allowing an appropriate time interval for collisions to occur, 2+2 resonance-enhanced multiphoton ionization is used (through the a 1 Π g left-arrow X 1 Σ + g transition) to detect the relative population of the pumped level and other levels to which rotational energy transfer has occurred. We have performed a series of measurements in which a single even rotational level (J i =0--14) is excited and the time-dependent level populations are recorded at three or more delay times. This data set is then globally fit to determine the best set of state-to-state rate constants. The fitting procedure does not place any constraints (such as an exponential gap law) on the J or energy dependence of the rates. We compare our measurements and best-fit rates with results predicted from phenomenological rate models and from a semiclassical scattering calculation of Koszykowski et al. [J. Phys. Chem. 91, 41 (1987)]. Excellent agreement is obtained with two of the models and with the scattering calculation. We also test the validity of the energy-corrected sudden (ECS) scaling theory for N 2 by using our experimental transfer rates as basis rates (J=L→0), finding that the ECS scaling expressions accurately predict the remaining rates

  10. Unravelling radiative energy transfer in solid-state lighting

    Science.gov (United States)

    Melikov, Rustamzhon; Press, Daniel Aaron; Ganesh Kumar, Baskaran; Sadeghi, Sadra; Nizamoglu, Sedat

    2018-01-01

    Today, a wide variety of organic and inorganic luminescent materials (e.g., phosphors, quantum dots, etc.) are being used for lighting and new materials (e.g., graphene, perovskite, etc.) are currently under investigation. However, the understanding of radiative energy transfer is limited, even though it is critical to understand and improve the performance levels of solid-state lighting devices. In this study, we derived a matrix approach that includes absorption, reabsorption, inter-absorption and their iterative and combinatorial interactions for one and multiple types of fluorophores, which is simplified to an analytical matrix. This mathematical approach gives results that agree well with the measured spectral and efficiency characteristics of color-conversion light-emitting diodes. Moreover, it also provides a deep physical insight by uncovering the entire radiative interactions and their contribution to the output optical spectrum. The model is universal and applicable for all kinds of fluorophores.

  11. Measurement of local heat transfer coefficient during gas–liquid Taylor bubble train flow by infra-red thermography

    International Nuclear Information System (INIS)

    Mehta, Balkrishna; Khandekar, Sameer

    2014-01-01

    Highlights: • Infra-red thermographic study of Taylor bubble train flow in square mini-channel. • Design of experiments for measurement of local streamwise Nusselt number. • Minimizing conjugate heat transfer effects and resulting errors in data reduction. • Benchmarking against single-phase flow and three-dimensional computations. • Local heat transfer enhancement up to two times due to Taylor bubble train flow. -- Abstract: In mini/micro confined internal flow systems, Taylor bubble train flow takes place within specific range of respective volume flow ratios, wherein the liquid slugs get separated by elongated Taylor bubbles, resulting in an intermittent flow situation. This unique flow characteristic requires understanding of transport phenomena on global, as well as on local spatio-temporal scales. In this context, an experimental design methodology and its validation are presented in this work, with an aim of measuring the local heat transfer coefficient by employing high-resolution InfraRed Thermography. The effect of conjugate heat transfer on the true estimate of local transport coefficients, and subsequent data reduction technique, is discerned. Local heat transfer coefficient for (i) hydrodynamically fully developed and thermally developing single-phase flow in three-side heated channel and, (ii) non-boiling, air–water Taylor bubble train flow is measured and compared in a mini-channel of square cross-section (5 mm × 5 mm; D h = 5 mm, Bo ≈ 3.4) machined on a stainless steel substrate (300 mm × 25 mm × 11 mm). The design of the setup ensures near uniform heat flux condition at the solid–fluid interface; the conjugate effects arising from the axial back conduction in the substrate are thus minimized. For benchmarking, the data from single-phase flow is also compared with three-dimensional computational simulations. Depending on the employed volume flow ratio, it is concluded that enhancement of nearly 1.2–2.0 times in time

  12. Spectrum and energy levels of four-times-ionized niobium

    International Nuclear Information System (INIS)

    Kagan, D.T.; Conway, J.G.; Meinders, E.

    1981-01-01

    The 4p 6 nl spectrum of Nb 4+ was measured and analyzed. The spectrum was excited in a vacuum sliding spark source with a peak current of 800 A and a pulse width of 70 μsec. The analysis of the spectrum has extended the 12 known lines to 84 and the 10 known levels to 30. The ionization energy was calculated to be 407897 +- 40 cm -1 . There is strong evidence that the 4p 5 4d 2 configurations interacts strongly with the 4p 6 nf configuration. In addition, the hyperfine splitting of the 4p 6 6s level has been observed and measured to be 1.1 cm -1

  13. The cosmic ray spectrum and composition measured by KASCADE-Grande between 10{sup 16} eV and 10{sup 18} eV

    Energy Technology Data Exchange (ETDEWEB)

    Bertaina, M., E-mail: bertaina@to.infn.it [Department of Physics, University of Torino and INFN, Torino (Italy); Apel, W.D. [Institut für Kernphysik, KIT – Karlsruher Institut für Technologie (Germany); Arteaga-Velázquez, J.C. [Institute of Physics and Mathematics, Universidad Michoacana de San Nicolas de Hidalgo, Morelia (Mexico); Bekk, K. [Institut für Kernphysik, KIT – Karlsruher Institut für Technologie (Germany); Blümer, J. [Institut für Kernphysik, KIT – Karlsruher Institut für Technologie (Germany); Institut für Experimentelle Kernphysik, KIT – Karlsruher Institut für Technologie (Germany); Bozdog, H. [Institut für Kernphysik, KIT – Karlsruher Institut für Technologie (Germany); Brancus, I.M. [Horia Hulubei National Institute of Physics and Nuclear Engineering, Bucharest (Romania); Cantoni, E. [Department of Physics, University of Torino and INFN, Torino (Italy); Osservatorio Astrofisico di Torino, INAF Torino (Italy); Chiavassa, A. [Department of Physics, University of Torino and INFN, Torino (Italy); Cossavella, F. [Institut für Experimentelle Kernphysik, KIT – Karlsruher Institut für Technologie (Germany); Daumiller, K. [Institut für Kernphysik, KIT – Karlsruher Institut für Technologie (Germany); Souza, V. de [Universidade São Paulo, Instituto de Física de São Carlos (Brazil); and others

    2014-11-15

    The shape and composition of the primary spectrum of cosmic rays are key elements to understand the origin, acceleration and propagation of the Galactic cosmic rays. Besides the well known knee and ankle features, the recent results of KASCADE-Grande indicate that the measured energy spectrum exhibits also a less pronounced but still clear deviation from a single power law between the knee and the ankle, with a spectral hardening at 2 × 10{sup 16} eV and a steepening at 10{sup 17} eV. The average mass composition gets heavier after the knee till 10{sup 17} eV where a bending of the heavy component is observed. An indication of a hardening of the light component just above 10{sup 17} eV has been measured as well. In this paper the major results obtained so far by the KASCADE-Grande experiment are reviewed.

  14. Measurement of the time dependent neutron energy spectrum in the 'DENA' plasma focus device

    Energy Technology Data Exchange (ETDEWEB)

    Abdollahzadeh, M [Department of Physics, Imam Husein University, PO Box 16575-347, Tehran (Iran, Islamic Republic of); Sadat kiai, S M [Nuclear Science and Technology Research Institute (NSTRI), Nuclear Science Research School, A.E.O.I., PO Box 14155-1339, Tehran (Iran, Islamic Republic of); Babazadeh, A R [Physics Department, Qom University, PO Box 37165, Qom (Iran, Islamic Republic of)

    2008-10-15

    An extended time of flight method is used to determine the time dependent neutron energy spectrum in the Filippove type 'Dena' plasma focus (90 kJ, 25 kV, 288 {mu}F), filled with deuterium gas. An array of 5 detectors containing NE-102 plastic scintillators+photomultipliers is used. The number and position of the detectors are determined by a Monte Carlo program and the MCNP code. This paper briefly describes the simulation method and presents the experimental measurements and their results. The mechanisms of neutron production (thermonuclear and non-thermonuclear) and their time variations are discussed.

  15. Width of electromagnetic wave instability spectrum in tungsten plate

    International Nuclear Information System (INIS)

    Rinkevich, A.B.

    1995-01-01

    Based on the study of high-frequency signal modulation and spectrum analysis of the envelope a measurement of spectrum width for electromagnetic wave instability was carried out under conditions of current pulse action on tungsten plate in magnetic field. The existence of amplitude-frequency wave modulation was revealed. The width of current disturbance spectrum in a specimen was evaluated. Current disturbances are shown to cause the instability of electromagnetic wave. 11 refs.; 6 figs

  16. Modelling the TSZ power spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Suman [Los Alamos National Laboratory; Shaw, Laurie D [YALE; Nagai, Daisuke [YALE

    2010-01-01

    The structure formation in university is a hierarchical process. As universe evolves, tiny density fluctuations that existed in the early universe grows under gravitational instability to form massive large scale structures. The galaxy clusters are the massive viralized objects that forms by accreting smaller clumps of mass until they collapse under their self-gravity. As such galaxy clusters are the youngest objects in the universe which makes their abundance as a function of mass and redshift, very sensitive to dark energy. Galaxy clusters can be detected by measuring the richness in optical waveband, by measuring the X-ray flux, and in the microwave sky using Sunyaev-Zel'dovich (SZ) effect. The Sunyaev-Zel'dovich (SZ) effect has long been recognized as a powerful tool for detecting clusters and probing the physics of the intra-cluster medium. Ongoing and future experiments like Atacama Cosmology Telescope, the South Pole Telescope and Planck survey are currently surveying the microwave sky to develop large catalogs of galaxy clusters that are uniformly selected by the SZ flux. However one major systematic uncertainties that cluster abundance is prone to is the connection between the cluster mass and the SZ flux. As shown by several simulation studies, the scatter and bias in the SZ flux-mass relation can be a potential source of systematic error to using clusters as a cosmology probe. In this study they take a semi-analytic approach for modeling the intra-cluster medium in order to predict the tSZ power spectrum. The advantage of this approach is, being analytic, one can vary the parameters describing gas physics and cosmology simultaneously. The model can be calibrated against X-ray observations of massive, low-z clusters, and using the SZ power spectrum which is sourced by high-z lower mass galaxy groups. This approach allows us to include the uncertainty in gas physics, as dictated by the current observational uncertainties, while measuring the

  17. Observational aspects of the microwave cosmic background spectrum

    International Nuclear Information System (INIS)

    Martin, D.H.

    1982-01-01

    The discovery of the isotropic microwave background, in 1964, was followed by a decade of careful measurements of the background flux throughout the centimetric and millimetric ranges of wavelength. The results of these measurements are not inconsistent with a Planckian spectrum but the absolute precision of the measurements is not as high as is frequently assumed. More recently attention has turned to searches for variations in the flux density with direction in the sky, while preparations are made in laboratories around the world for a second wave of measurements of the spectrum which are to have a much higher absolute precision. The author points out the limitations in present knowledge of the microwave background, identifies the observational difficulties in improving that knowledge and reports on some of the plans for future measurements. (Auth.)

  18. Moisture transfer through the membrane of a cross-flow energy recovery ventilator: Measurement and simple data-driven modeling

    Science.gov (United States)

    CR Boardman; Samuel V. Glass

    2015-01-01

    The moisture transfer effectiveness (or latent effectiveness) of a cross-flow, membrane based energy recovery ventilator is measured and modeled. Analysis of in situ measurements for a full year shows that energy recovery ventilator latent effectiveness increases with increasing average relative humidity and surprisingly increases with decreasing average temperature. A...

  19. Heat transfer coefficient for boiling carbon dioxide

    DEFF Research Database (Denmark)

    Knudsen, Hans Jørgen Høgaard; Jensen, Per Henrik

    1998-01-01

    Heat transfer coefficient and pressure drop for boiling carbon dioxide (R744) flowing in a horizontal pipe has been measured. The calculated heat transfer coeeficient has been compared with the Chart correlation of Shah. The Chart Correlation predits too low heat transfer coefficient but the ratio...... between the measured and the calculated heat transfer coefficient is nearly constant and equal 1.9. With this factor the correlation predicts the measured data within 14% (RMS). The pressure drop is of the same order as the measuring uncertainty and the pressure drop has not been compared with correlation's....

  20. Comet 67P/Churyumov-Gerasimenko Surface Composition as a Playground for Radiative Transfer Modeling and Laboratory Measurements: an international ISSI team

    Science.gov (United States)

    Stephan, K.; Ciarniello, M.; Beck, P.; Filacchione, G.; Moroz, L.; Pilorget, C.; Pommerol, A.; Quirico, E.; Raponi, A.; Schröder, S.; Kappel, D.; Vinogradoff, V.; Istiqomah, I.; Rousseau, B.

    2017-12-01

    Remote sensing observations at visible-infrared (VIS-IR) wavelengths of the nucleus of comet 67P/Churyumov-Gerasimenko performed by VIRTIS (Coradini et al., 2007) aboard the Rosetta mission have revealed a surface ubiquitously covered by low-albedo material (Capaccioni et al., 2015; Ciarniello et al., 2015), characterized by the presence of refractory and semi-volatile organics and dark opaque phases (Capaccioni et al., 2015; Quirico et al., 2016). However, a quantitative determination of the physical properties (grain size, porosity) and chemical composition of the surface regolith, from spectrophotometric analysis, is still missing. This subject will be investigated within an international team hosted by ISSI (International Space Science Institute), taking advantage of available and dedicated laboratory reflectance measurements on cometary analogue samples and radiative transfer models (Hapke, 2012; Shkuratov et al., 1999; Monte Carlo ray-tracing), applied to Rosetta spectrophotometric observations of the nucleus. The convergence between models and measurements will allow us to provide a thorough characterization of 67P/Churyumov-Gerasimenko surface. At the same time, the comparison of theoretical predictions with results from laboratory reflectance spectroscopy on powders of analog materials give us the possibility to constrain the capability of the models to characterize their composition (endmember abundances and mixing modalities) and physical properties. We report about the state of the art of laboratory reflectance spectroscopy and spectral modeling applied to 67P/Churyumov-Gerasimenko VIS-IR spectrum as well as preliminary results of the team activity and planned future work. Acknowledgements: the team thanks ISSI-Switzerland for the logistic and financial support.