WorldWideScience

Sample records for transcervical carotid stenting

  1. Carotid Angioplasty and Stenting

    Science.gov (United States)

    Carotid angioplasty and stenting Overview Carotid angioplasty (kuh-ROT-id AN-jee-o-plas-tee) and stenting ... to better see and examine the blood vessels. Food and medications You'll receive instructions on what ...

  2. Angioplasty and stent placement - carotid artery

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002953.htm Angioplasty and stent placement - carotid artery To use the sharing features ... to remove plaque buildup ( endarterectomy ) Carotid angioplasty with stent placement Description Carotid angioplasty and stenting (CAS) is ...

  3. Angioplasty and stent placement - carotid artery - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000235.htm Angioplasty and stent placement - carotid artery - discharge To use the sharing ... the hospital. You may have also had a stent (a tiny wire mesh tube) placed in the ...

  4. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study) : an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Joerg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Bradbury, A.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molynewc, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Hendriks, J. M. H.; Hendriks, J. M.

    2010-01-01

    Background Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. Methods The International Carotid

  5. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2010-03-20

    Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.

  6. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial.

    NARCIS (Netherlands)

    Ederle, J.; Dobson, J.; Featherstone, R.L.; Bonati, L.H.; Worp, H.B. van der; Borst, G.J. de; Lo, T.H.; Gaines, P.; Dorman, P.J.; Macdonald, S.; Lyrer, P.A.; Hendriks, J.M.; McCollum, C.; Nederkoorn, P.J.; Brown, M.M.; Blankensteijn, J.D.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  7. Carotid artery stenting compared with endarterectomy in patients with symptomatic carotid stenosis (International Carotid Stenting Study): an interim analysis of a randomised controlled trial

    NARCIS (Netherlands)

    Ederle, Jörg; Dobson, Joanna; Featherstone, Roland L.; Bonati, Leo H.; van der Worp, H. Bart; de Borst, Gert J.; Lo, T. Hauw; Gaines, Peter; Dorman, Paul J.; Macdonald, Sumaira; Lyrer, Philippe A.; Hendriks, Johanna M.; McCollum, Charles; Nederkoorn, Paul J.; Brown, Martin M.; Algra, A.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Bonati, L. H.; Coward, L.; Dobson, J.; Ederle, J.; Featherstone, R. F.; Tindall, H.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Chan, A.; Chu, P.; Clark, D.; Dewey, H.; Donnan, G.; Fell, G.; Hoare, M.; Molan, M.; Roberts, A.; Roberts, N.; Beiles, B.; Bladin, C.; Clifford, C.; Grigg, M.; New, G.; Bell, R.; Bower, S.; Chong, W.; Holt, M.; Saunder, A.; Than, P. G.; Gett, S.; Leggett, D.; McGahan, T.; Quinn, J.; Ray, M.; Wong, A.; Woodruff, P.; Foreman, R.; Schultz, D.; Scroop, R.; Stanley, B.; Allard, B.; Atkinson, N.; Cambell, W.; Davies, S.; Field, P.; Milne, P.; Mitchell, P.; Tress, B.; Yan, B.; Beasley, A.; Dunbabin, D.; Stary, D.; Walker, S.; Cras, P.; d'Archambeau, O.; Hendriks, J. M. H.; van Schil, P.; St Blasius, A. Z.; Bosiers, M.; Deloose, K.; van Buggenhout, E.; de Letter, J.; Devos, V.; Ghekiere, J.; Vanhooren, G.; Astarci, P.; Hammer, F.; Lacroix, V.; Peeters, A.; Verbist, J.; Blair, J.-F.; Caron, J. L.; Daneault, N.; Giroux, M.-F.; Guilbert, F.; Lanthier, S.; Lebrun, L.-H.; Oliva, V.; Raymond, J.; Roy, D.; Soulez, G.; Weill, A.; Hill, M.; Hu, W.; Hudion, M.; Morrish, W.; Sutherland, G.; Wong, J.; Albäck, A.; Harno, H.; Ijäs, P.; Kaste, M.; Lepäntalo, M.; Mustanoja, S.; Paananen, T.; Porras, M.; Putaala, J.; Railo, M.; Sairanen, T.; Soinne, L.; Vehmas, A.; Vikatmaa, P.; Goertler, M.; Halloul, Z.; Skalej, M.; Brennan, P.; Kelly, C.; Leahy, A.; Moroney, J.; Thornton, J.; Koelemay, M. J. W.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van der Lugt, A.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van Urk, H.; Verhagen, H. J. M.; Bruijninckx, C. M. A.; de Bruijn, S. F.; Keunen, R.; Knippenberg, B.; Mosch, A.; Treurniet, F.; van Dijk, L.; van Overhagen, H.; Wever, J.; de Beer, F. C.; van den Berg, J. S. P.; van Hasselt, B. A. A. M.; Zeilstra, D. J.; Boiten, J.; van Otterloo, J. C. A. de Mol; de Vries, A. C.; Lycklama a Nijeholt, G. J.; van der Kallen, B. F. W.; Blankensteijn, J. D.; de Leeuw, F. E.; Kool, L. J. Schultze; van der Vliet, J. A.; de Borst, G. J.; de Kort, G. A. P.; Kapelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F.; van der Worp, H. B.; Verhagen, H.; Barber, P. A.; Bourchier, R.; Hill, A.; Holden, A.; Stewart, J.; Bakke, S. J.; Krohg-Sørensen, K.; Skjelland, M.; Tennøe, B.; Bialek, P.; Biejat, Z.; Czepiel, W.; Czlonkowska, A.; Dowzenko, A.; Jedrzejewska, J.; Kobayashi, A.; Lelek, M.; Polanski, J.; Kirbis, J.; Milosevic, Z.; Zvan, B.; Blasco, J.; Chamorro, A.; Macho, J.; Obach, V.; Riambau, V.; San Roman, L.; Branera, J.; Canovas, D.; Estela, Jordi; Gaibar, A. Gimenez; Perendreu, J.; Björses, K.; Gottsater, A.; Ivancev, K.; Maetzsch, T.; Sonesson, B.; Berg, B.; Delle, M.; Formgren, J.; Gillgren, P.; Kall, T.-B.; Konrad, P.; Nyman, N.; Takolander, R.; Andersson, T.; Malmstedt, J.; Soderman, M.; Wahlgren, C.; Wahlgren, N.; Binaghi, S.; Hirt, L.; Michel, P.; Ruchat, P.; Engelter, S. T.; Fluri, F.; Guerke, L.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E.-W.; Stierli, P.; Wasner, M.; Wetzel, S.; Bonvin, C.; Kalangos, A.; Lovblad, K.; Murith, M.; Ruefenacht, D.; Sztajzel, R.; Higgins, N.; Kirkpatrick, P. J.; Martin, P.; Varty, K.; Adam, D.; Bell, J.; Crowe, P.; Gannon, M.; Henderson, M. J.; Sandler, D.; Shinton, R. A.; Scriven, J. M.; Wilmink, T.; D'Souza, S.; Egun, A.; Guta, R.; Punekar, S.; Seriki, D. M.; Thomson, G.; Brennan, J. A.; Enevoldson, T. P.; Gilling-Smith, G.; Gould, D. A.; Harris, P. L.; McWilliams, R. G.; Nasser, H.-C.; White, R.; Prakash, K. G.; Serracino-Inglott, F.; Subramanian, G.; Symth, J. V.; Walker, M. G.; Clarke, M.; Davis, M.; Dixit, S. A.; Dorman, P.; Dyker, A.; Ford, G.; Golkar, A.; Jackson, R.; Jayakrishnan, V.; Lambert, D.; Lees, T.; Louw, S.; Macdonald, S.; Mendelow, A. D.; Rodgers, H.; Rose, J.; Stansby, G.; Wyatt, M.; Baker, T.; Baldwin, N.; Jones, L.; Mitchell, D.; Munro, E.; Thornton, M.; Baker, D.; Davis, N.; Hamilton, G.; McCabe, D.; Platts, A.; Tibballs, J.; Cleveland, T.; Dodd, D.; Lonsdale, R.; Nair, R.; Nassef, A.; Nawaz, S.; Venables, G.; Belli, A.; Cloud, G.; Halliday, A.; Markus, H.; McFarland, R.; Morgan, R.; Pereira, A.; Thompson, A.; Chataway, J.; Cheshire, N.; Gibbs, R.; Hammady, M.; Jenkins, M.; Malik, I.; Wolfe, J.; Adiseshiah, M.; Bishop, C.; Brew, S.; Brookes, J.; Jäger, R.; Kitchen, N.; Ashleigh, R.; Butterfield, S.; Gamble, G. E.; McCollum, C.; Nasim, A.; O'Neill, P.; Edwards, R. D.; Lees, K. R.; MacKay, A. J.; Moss, J.

    2010-01-01

    BACKGROUND: Stents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy. METHODS: The International

  8. Multidisciplinary approach to carotid stenting.

    Science.gov (United States)

    Mak, C S; Chambers, B R; Clark, D J; Molan, M; Brooks, M; Roberts, N; Fell, G; Roberts, A K; New, G; Donnan, G A

    2011-11-01

    Stroke neurologists, vascular surgeons, interventional neuroradiologists and interventional cardiologists have embraced carotid angioplasty and stenting (CAS) because of potential advantages over carotid endarterectomy (CEA). At Austin Health, a multidisciplinary neuro-interventional group was formed to standardise indications and facilitate training. The aims of this study were to describe our organisational model and to determine whether 30-day complications and early outcomes were similar to those of major trials. A clinical protocol was developed to ensure optimal management. CAS was performed on patients with high medical risk for CEA, with technically difficult anatomy for CEA, or who were randomised to CAS in a trial. From October 2003 to May 2008, 47 patients (34 male, mean age 71.5) underwent CAS of 50 carotid arteries. Forty-three cases had ipsilateral carotid territory symptoms within the previous 12 months. The main indications for CAS were high risk for CEA (n= 17) and randomised to CAS (n= 21). Interventionists were proctored in 27 cases. The procedural success rate was 94% with two cases abandoned because of anatomical problems and one because of on-table angina. Hypotension requiring vasopressor therapy occurred in 12 cases (24%). The duration of follow up was one to 44 months (mean 6.8 months). The 30-day rate of peri-procedural stroke or death was 6% and the one-year rate of peri-procedural stroke or death or subsequent ipsilateral stroke was 10.6%. Restenosis occurred in 13% (all asymptomatic). A multidisciplinary approach is a useful strategy for initiating and sustaining a CAS programme. © 2011 The Authors. Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  9. Long-term results after carotid artery stenting. Restenosis after carotid artery stenting using self-expandable stent

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Furui, Eisuke; Tsuboi, Ken; Takahashi, Akira; Ezura, Masayuki

    2008-01-01

    Carotid artery stenting has emerged as an acceptable treatment alternative in patients with carotid artery stenosis. Although early clinical results of carotid artery stenting have shown promise, long, term clinical results remain less certain. We report the frequency, management, and clinical results of in-stent restenosis after carotid artery stenting using a self-expandable stent. Between August 1998 and September 2004, 80 carotid artery stenting procedures in 78 patients were performed. We evaluated 76 of the 80 procedures in 75 of the 78 patients treated during this period who had a minimum 6-month clinical and imaging (ultrasound and/or magnetic resonance angiography) follow-up. Recurrent stenosis (≥50%) after carotid artery stenting occurred in 3 (3.9%) patients. The recurrent stenosis occurred within one year after the procedure in all cases. The low rate of in-stent restenosis using self-expandable stent suggested that carotid artery stenting may be an effective alternative treatment for carotid artery stenosis, but more data of long-term follow-up are required. (author)

  10. Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Chang Woo; Kim, Dong Hyun; Hong, Seung; Jeong; Kim, Young Suk; Byun, Joo Nam; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Ahn, Seong Hwan [Dept. of Neurology, Chosun University College of Medicine, Gwangju (Korea, Republic of)

    2011-10-15

    To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient.

  11. Thalamic hemorrhage following carotid angioplasty and stenting

    International Nuclear Information System (INIS)

    Friedman, Jonathan A.; Kallmes, David F.; Wijdicks, Eelco F.M.

    2004-01-01

    Carotid angioplasty and stenting (CAS) has emerged as an alternative treatment of carotid stenosis for patients poorly suited for endarterectomy. Intracerebral hemorrhage following carotid revascularization is rare and thought to be related to hyperperfusion injury in most cases. Early experience suggests an increased incidence of hemorrhage following CAS as compared to endarterectomy. We describe a patient who suffered a thalamic hemorrhage following CAS. Because this hemorrhage occurred in a vascular territory unlikely to have been supplied by the treated artery, this case suggests that the mechanism of intracerebral hemorrhage following CAS may in some cases be different from the hyperperfusion hemorrhage classically described following endarterectomy. (orig.)

  12. The Effect of Stent Cell Geometry on Carotid Stenting Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Alparslan, Burcu, E-mail: burcu.alparslan@gmail.com [Yozgat State Hospital, Radiology Clinic (Turkey); Nas, Omer Fatih, E-mail: omerfatihnas@gmail.com [Uludag University Faculty of Medicine, Department of Radiology (Turkey); Eritmen, Ulku Turpcu, E-mail: drulkutur@hotmail.com.tr [Special Eregli Anatolia Hospital, Radiology Clinic (Turkey); Duran, Selcen, E-mail: selcenduran16@hotmail.com [Yerkoy State Hospital, Neurology Clinic (Turkey); Ozkaya, Guven, E-mail: ozkaya@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Biostatistics (Turkey); Hakyemez, Bahattin, E-mail: bhakyemez@uludag.edu.tr [Uludag University Faculty of Medicine, Department of Radiology (Turkey)

    2016-04-15

    PurposeThe aim of this study was to investigate the effect of stent cell geometry on midterm results of carotid artery stenting (CAS).Materials and MethodOne hundred fifty-five patients underwent CAS between February 2010 and December 2012. Ninety-one open- and 84 closed-cell stents were used in this non-randomized, retrospective study. Periprocedural complications were defined as the ones happened during the procedure or within 30 days afterwards. Starting from the 6th month after the procedure, in-stent restenosis was detected with multidetector computed tomography angiography and classified into four groups from focal restenosis to occlusion.ResultsEleven complications were encountered in the periprocedural period (four on the open- and seven on the closed-cell group). Total complication rate was 6.3 % (11/175). No significant difference was detected in terms of periprocedural complications between two groups (p = 0.643). There was statistically significant difference between stent design groups in regard to radiological findings (p = 0.002). Sixteen of open-cell stents and three of closed-cell stents had focal restenosis. One closed-cell stent had diffuse proliferative restenosis and one open-cell stent had total occlusion.ConclusionIn-stent restenosis was more common in open-cell stent group, which have larger free cell area than closed-cell stents. Although our radiologic findings promote us to use closed-cell design if ‘possible’, no difference was detected in terms of clinical outcomes.

  13. MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen

    International Nuclear Information System (INIS)

    Straube, T.; Wolf, S.; Alfke, K.; Jansen, O.; Flesser, A.; Deli, M.; Nabavi, A.

    2005-01-01

    Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency artifacts, whereas a reduction in linking elements between stent segments and a change in diameter of stent struts improves visualization of the stent lumen. By increasing the flip angle in a CE-MRA, visualization of the stent lumen is possible in both mediloy and nitinol stents. Conclusion: The choice of stent material and changes in stent geometry as well as the optimization of the flip angle of the CE-MRA may reduce susceptibility and radiofrequency artifacts, rendering feasible the CE-MRA of a stented carotid artery. (orig.)

  14. Hyperperfusion syndrome after carotid stent angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Reith, W.; Krick, C.; Karp, K.; Zimmer, A.; Struffert, T.; Kuehn, A.L.; Papanagiotou, P. [University of the Saarland, Department for Interventional and Diagnostic Neuroradiology, Homburg (Germany); Roth, C.; Haass, A. [University of the Saarland, Clinic for Neurology, Homburg (Germany)

    2009-03-15

    This study assesses the incidence and causes of hyperperfusion syndrome occurring after carotid artery stenting (CAS). We retrospectively reviewed the clinical database of 417 consecutive patients who were treated with CAS in our department to identify patients who developed hyperperfusion syndrome and/or intracranial hemorrhage. Magnetic resonance imaging (MRI) including fluid-attenuated inversion recovery and diffusion-weighted imaging was performed before and after CAS in 269 cases. A Spearman's rho nonparametric correlation was performed to determine whether there was a correlation between the occurrence/development of hyperperfusion syndrome and the patient's age, degree of stenosis on the stented and contralateral side, risk factors such as diabetes, smoking, hypertension, adiposity, gender and fluoroscopy time, and mean area of postprocedural lesions as well as preexisting lesions. Significance was established at p < 0.05. Of the 417 carotid arteries stented and where MRI was also completed, we found hyperperfusion syndrome in 2.4% (ten cases). Patients who had preexisting brain lesions (previous or acute stroke) were at a higher risk of developing hyperperfusion syndrome (p = 0.022; Spearman's rho test). We could not validate any correlation with the other patient characteristics. Extensive microvascular disease may be a predictor of hyperperfusion syndrome after carotid stent placement. We believe that further studies are warranted to predict more accurately which patients are at greater risk of developing this often fatal complication. (orig.)

  15. Carotid angioplasty and stenting in the elderly

    International Nuclear Information System (INIS)

    Kadkhodayan, Yasha; Cross, DeWitte T.; Moran, Christopher J.; Derdeyn, Colin P.

    2007-01-01

    To investigate the technical success rate as well as the procedural and mid-term complication rates of carotid angioplasty and stenting in elderly patients, a group excluded from large randomized endarterectomy trials given their perceived high surgical risk. Of 200 consecutive carotid angioplasty and/or stenting procedures performed between March 1996 and March 2005, 21 procedures were performed without cerebral protection devices in 20 patients over the age of 79 years (mean age: 83 years, 12 men, eight women). These patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and mid-term complication rates were calculated and compared to a previously published cohort of 133 consecutive patients ≤79 years of age who also underwent endovascular treatment at our institution. Carotid stenosis was reduced from a mean of 82% to no significant stenosis in all procedures. The procedural stroke rate was zero of 21 procedures. The procedural transient ischemic attack rate (TIA) was one of 21 procedures (4.8%). Mean follow-up was 24.6 months (range: 1.0-79.5 months) with at least a 30-day follow-up for 20 of the 21 procedures (95.2%). There were no new strokes. There was one recurrent ipsilateral TIA at 1.9 months. In five cases with follow-up carotid ultrasonography, no hemodynamically significant restenosis had occurred. There were three myocardial infarctions (MI) occurring at 0.5, 2.1, and 15.2 months, of which the last MI was fatal. The composite 30-day stroke and death rate was zero of 21 procedures (95% confidence interval: 0-14%). No significant difference was found in the 30-day rate of stroke, TIA, MI, or death between the elderly and younger patients. Carotid angioplasty and stenting in elderly patients can be performed successfully with acceptable procedural and mid-term complication rates comparable to younger patients. (orig.)

  16. Cognitive changes after carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M. [University of the Saarland, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Supprian, T.; Falkai, P.; Reith, W. [University of the Saarland, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2006-05-15

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9{+-}1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  17. Cognitive changes after carotid artery stenting

    International Nuclear Information System (INIS)

    Grunwald, I.Q.; Politi, M.; Struffert, T.; Krick, C.; Backens, M.; Supprian, T.; Falkai, P.; Reith, W.

    2006-01-01

    We aimed to test changes in cognitive performance after carotid artery stenting (CAS). Ten patients were neuropsychologically tested at least 24 h before and 48 h after CAS. To diminish thromboembolic events, we used a proximal protection device. The following neuropsychological tests were selected: The Mini Mental State Examination (MMSE), symbol digit test and subtests of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD) battery (verbal fluency, constructional practice, word list memory and delayed recall). Affective state was determined by the Beck Depression Score (BDS). No patient suffered from depression (BDS <1) or dementia (MMSE 29.9±1.5). Nine of the ten patients (P=0.12) showed increased speed in the Number Connection Test (NCT) (corresponding to trail making test). Most patients showed better or similar results concerning delayed recall (P=0.31). No change was observed in the symbol digit test, word list memory, verbal fluency or constructional practice. Better results concerning NCT and delayed recall after carotid stenting might be due to improved brain perfusion. After CAS, cognitive and memory performance seem to improve. Further studies with different time intervals and more refined testing, as well as perfusion-weighted imaging, are needed. (orig.)

  18. Angiographic CT: in vitro comparison of different carotid artery stents-does stent orientation matter?

    Science.gov (United States)

    Lettau, Michael; Bendszus, Martin; Hähnel, Stefan

    2013-06-01

    Our aim was to evaluate the in vitro visualization of different carotid artery stents on angiographic CT (ACT). Of particular interest was the influence of stent orientation to the angiography system by measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether ACT can be used to detect restenosis within the stent. ACT appearances of 17 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. Stents were placed in different orientations to the angiography system. Standard algorithm image reconstruction and stent-optimized algorithm image reconstruction was performed. For each stent, ALN was calculated. With standard algorithm image reconstruction, ALN ranged from 19.0 to 43.6 %. With stent-optimized algorithm image reconstruction, ALN was significantly lower and ranged from 8.2 to 18.7 %. Stent struts could be visualized in all stents. Differences in ALN between the different stent orientations to the angiography system were not significant. ACT evaluation of vessel patency after stent placement is possible but is impaired by ALN. Stent orientation of the stents to the angiography system did not significantly influence ALN. Stent-optimized algorithm image reconstruction decreases ALN but further research is required to define the visibility of in-stent stenosis depending on image reconstruction.

  19. Current global status of carotid artery stent placement.

    Science.gov (United States)

    Wholey, M H; Wholey, M; Bergeron, P; Diethrich, E B; Henry, M; Laborde, J C; Mathias, K; Myla, S; Roubin, G S; Shawl, F; Theron, J G; Yadav, J S; Dorros, G; Guimaraens, J; Higashida, R; Kumar, V; Leon, M; Lim, M; Londero, H; Mesa, J; Ramee, S; Rodriguez, A; Rosenfield, K; Teitelbaum, G; Vozzi, C

    1998-05-01

    Our purpose was to review the current status of carotid artery stent placement throughout the world. Surveys were sent to major interventional centers in Europe, North and South America, and Asia. Information from peer-reviewed journals was also included and supplemented the survey. The survey asked various questions regarding the patients enrolled, procedure techniques, and results of carotid stenting, including complications and restenosis. Of the centers which were sent surveys, 24 responded. The total number of endovascular carotid stent procedures that have been performed worldwide to date included 2,048 cases, with a technical success of 98.6%. Complications that occurred during carotid stent placement or within a 30-day period following placement were recorded. Overall, there were 63 minor strokes, with a rate of occurrence of 3.08%. The total number of major strokes was 27, for a rate of 1.32%. There were 28 deaths within a 30-day postprocedure period, resulting in a mortality rate of 1.37%. Restenosis rates of carotid stenting have been 4.80% at 6 mo. Endovascular stent treatment of carotid artery atherosclerotic disease is growing as an alternative to vascular surgery, especially for patients that are at high risk for standard carotid endarterectomy. The periprocedural risks for major and minor strokes and death are generally acceptable at this early stage of development.

  20. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  1. Delayed cerebral infarction due to stent folding deformation following carotid artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kwon Duk; Lee, Kyung Yul; Suh, Sang Hyun [Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-12-15

    We report a case of delayed cerebral infarction due to stent longitudinal folding deformation following carotid artery stenting using a self-expandable stent with an open-cell design. The stented segment of the left common carotid artery was divided into two different lumens by this folding deformation, and the separated lumens became restricted with in-stent thrombosis. Although no established method of managing this rare complication exists, a conservative approach was taken with administration of anticoagulant and dual antiplatelet therapy. No neurological symptoms were observed during several months of clinical follow-up after discharge.

  2. Impact on outcome of different types of carotid stent: results from the European Registry of Carotid Artery Stenting.

    Science.gov (United States)

    Stabile, Eugenio; Giugliano, Giuseppe; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitrios; Sannino, Anna; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Rubino, Paolo; Esposito, Giovanni; Tesorio, Tullio

    2016-06-12

    Conflicting data exist on the impact on outcome of the use of different stent types during carotid artery stenting (CAS). The aim of this study was to evaluate clinical outcomes according to different carotid stent design among the population of the European Registry of Carotid Artery Stenting (ERCAS). The present study was conducted in 1,604 patients who underwent neuroprotected CAS in ERCAS. All types of commercially available carotid stent were used. Open-cell design stents were classified according to free cell area into 7.5 mm2. A total of 713 closed-cell, 456 hybrid-cell, 238 7.5 mm2 open-cell stents were implanted. Overall, the 30-day stroke and death rate was 1.37%. At 30 days, 19 strokes occurred (1.18%): eight in the group of patients treated with a closed-cell (1.12%), two in those with a hybrid-cell (0.44%), three in those with a 7.5 mm2 open-cell stent (3.05%) (p=0.045). Data of the present study suggest that, in the setting of neuroprotected CAS performed in high-volume centres by properly trained operators, the use of an open-cell design stent with a free cell area >7.5 mm2 may be associated with an increased 30-day stroke risk.

  3. Carotid angioplasty and stenting for symptomatic carotid kinking combined with stenosis

    Directory of Open Access Journals (Sweden)

    JIANG Xue-li

    2013-03-01

    Full Text Available Background Carotid endarterectomy (CEA is currently the preferred treatment for severe carotid kinking and stenosis. Kinking is generally believed to be a relative contraindication for endovascular stent placement. This article aims to study the necessity, feasibility and security of carotid angioplasty and stenting (CAS for symptomatic carotid kinking combined with stenosis, and summarize clinical experience of this disease according to therapeutic results. Methods Twenty-two cases with symptomatic carotid kinking and high-grade stenosis demonstrated by digital subtraction angiography (DSA were performed CAS. Their clinical manifestations, imaging features, procedure safety and follow-up data were collected and retrospectively analyzed. All patients understood CEA and voluntarily received CAS. Results Twenty-two cases with carotid kinking and stenosis were all successfully performed CAS (the success rate was 100% without stent-related disability or mortality. Twenty-four self-expandable stents were implanted. The mean degree of stenosis was reduced from 85.63%before stenting to 11.25% after stenting and the angles of kinking were improved from 120° (Metz' category. During the period of hospitalization, no transient ischemic attack (TIA or cerebral infarction occurred, and the clinical symptoms and signs of ischemia, such as dizziness and headache, were improved or disappeared. Besides, no permenant complications or deaths happened. All cases were followed up from 6 to 72 months, among whom 1 patient experienced contralateral carotid TIA, and 2 patients experienced ipsilateral carotid TIA (one indicated aspirin resistance in platelet aggregation test and the other showed restenosis in DSA. Computed tomography angiography (CTA of 10 patients and Duplex scan of 7 patients during the follow-up demonstrated carotid in good morphology and fluent blood flow, without kinking or restenosis. Conclusion CAS is a feasible and safe therapeutic method and

  4. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial

    NARCIS (Netherlands)

    Bonati, L.H.; Dobson, J.; Featherstone, R.L.; Ederle, J.; Worp, H.B. van der; Borst, G.J. de; Mali, W.P.; Beard, J.D.; Cleveland, T.; Engelter, S.T.; Lyrer, P.A.; Ford, G.A.; Dorman, P.J.; Brown, M.M.; Leeuw, F.E. de; et al.,

    2015-01-01

    BACKGROUND: Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. METHODS: Patients with symptomatic carotid

  5. Long-term outcomes after stenting versus endarterectomy for treatment of symptomatic carotid stenosis: the International Carotid Stenting Study (ICSS) randomised trial

    NARCIS (Netherlands)

    Bonati, Leo H.; Dobson, Joanna; Featherstone, Roland L.; Ederle, Jörg; van der Worp, H. Bart; de Borst, Gert J.; Mali, Willem P. Th M.; Beard, Jonathan D.; Cleveland, Trevor; Engelter, Stefan T.; Lyrer, Philippe A.; Ford, Gary A.; Dorman, Paul J.; Brown, Martin M.; Bamford, J.; Beard, J.; Bland, M.; Bradbury, A. W.; Brown, M. M.; Hacke, W.; Halliday, A.; Malik, I.; Mas, J. L.; McGuire, A. J.; Sidhu, P.; Venables, G.; Clifton, A.; Gaines, P.; Collins, R.; Molyneux, A.; Naylor, R.; Warlow, C.; Ferro, J. M.; Thomas, D.; Coward, L.; Dobson, J.; Doig, D.; Ederle, J.; Featherstone, R. F.; Kennedy, F.; Tindall, H.; Turner, E.; McCabe, D. J. H.; Wallis, A.; Brooks, M.; Chambers, B.; Koelemay, M. J. W.; Nederkoorn, P. J.; Reekers, J. A. A.; Roos, Y. B. W. E. M.

    2015-01-01

    Background Stenting is an alternative to endarterectomy for treatment of carotid artery stenosis, but long-term efficacy is uncertain. We report long-term data from the randomised International Carotid Stenting Study comparison of these treatments. Methods Patients with symptomatic carotid stenosis

  6. New ischaemic brain lesions on MRI after stenting or endarterectomy for symptomatic carotid stenosis: a substudy of the International Carotid Stenting Study (ICSS)

    NARCIS (Netherlands)

    Bonati, Leo H.; Jongen, Lisa M.; Haller, Sven; Flach, H. Zwenneke; Dobson, Joanna; Nederkoorn, Paul J.; Macdonald, Sumaira; Gaines, Peter A.; Waaijer, Annet; Waajier, Annet; Stierli, Peter; Jäger, H. Rolf; Lyrer, Philippe A.; Kappelle, L. Jaap; Wetzel, Stephan G.; van der Lugt, Aad; Mali, Willem P.; Brown, Martin M.; van der Worp, H. Bart; Engelter, Stefan T.; Koelemaij, M. J. W.; Majoie, C. B. L. M.; Reekers, J. A. A.; Roos, Y. B. W. E. M.; Flach, H. Z.; Hendriks, J. M.; Koudstaal, P. J.; Pattynama, P. M. T.; van Dijk, L. C.; van Sambeek, M. R. H. M.; van der Lugt, A.; van Urk, H.; Verhagen, H. J. M.; de Borst, G. J.; de Kort, G. A. P.; Jongen, L. M.; Kappelle, L. J.; Lo, T. H.; Mali, W. P. Th M.; Moll, F. L.; van der Worp, H. B.; Bonati, L. H.; Engelter, S. T.; Fluri, F.; Haller, S.; Jacob, A. L.; Kirsch, E.; Lyrer, P. A.; Radue, E.-W.; Stierli, P.

    2010-01-01

    BACKGROUND: The International Carotid Stenting Study (ICSS) of stenting and endarterectomy for symptomatic carotid stenosis found a higher incidence of stroke within 30 days of stenting compared with endarterectomy. We aimed to compare the rate of ischaemic brain injury detectable on MRI between the

  7. Efficacy of different types of self-expandable stents in carotid artery stenting for carotid bifurcation stenosis.

    Science.gov (United States)

    Liu, Ya-min; Qin, Hao; Zhang, Bo; Wang, Yu-jing; Feng, Jun; Wu, Xiang

    2016-02-01

    Both open and closed loop self-expandable stents were used in carotid artery stenting (CAS) for carotid bifurcation stenosis. We sought to compare the efficacy of two types of stents in CAS. The data of 212 patients treated with CAS (42 and 170 cases implanted with closed and open loop stents, respectively) for carotid bifurcation stenosis and distal filtration protection devices were retrospectively analyzed. Between closed and open loop stents, there were no significant differences in hospitalization duration, NIHSS score before and after the treatment, stenosis at 12th month, and cumulative incidence of primary endpoint events within 30 days or from the 31st day to the 12th month; while there were significant differences in hemodynamic changes and rate of difficulty in recycling distal filtration protection devices. Use of open vs. closed loop stents for carotid bifurcation stenosis seems to be associated with similar incidence of complications, except for greater rate of hemodynamic changes and lower rate of difficulty in recycling the distal filtration protection devices.

  8. Self expandable polytetrafluoroethylene stent for carotid blowout syndrome.

    Science.gov (United States)

    Tatar, E C; Yildirim, U M; Dündar, Y; Ozdek, A; Işik, E; Korkmaz, H

    2012-01-01

    Carotid blowout syndrome (CBS) is an emergency complication in patients undergoing treatment for head and neck cancers. The classical management of CBS is the ligation of the common carotid artery, because suturing is not be possible due to infection and necrosis of the field. In this case report, we present a patient with CBS, in whom we applied a self-expandable polytetrafluoroethylene (PTFE) stent and observed no morbidity. Endovascular stent is a life-saving technique with minimum morbidity that preserves blood flow to the brain. We believe that this method is preferable to ligation of the artery in CBS.

  9. Carotid angioplasty and stenting under protection. Techniques, results and limitations.

    Science.gov (United States)

    Henry, M; Polydorou, A; Henry, I; Anagnostopoulou, I S; Polydorou, I A; Hugel, M

    2006-10-01

    A carotid stenosis is responsible for about 30% of strokes occurring. Carotid endarterectomy (CEA) is considered to be the gold standard treatment of a carotid stenosis. Carotid angioplasty and stenting (CAS) is emerging as a new alternative treatment for a carotid artery stenosis, but the risk of neurological complications and brain embolism remains the major drawback to this procedure. Therefore, in order to reduce the risks, we need: 1) good indications, good patient and lesion selection; 2) correct techniques; 3) brain protection devices (cerebral protection devices should be routinely used and are mandatory for any procedure); 4) 3 types of protection devices are available, but filters are the most commonly used (all protection devices have limitations and cannot prevent from all embolic events; however, neurological complications can be reduced by 60%); 5) a good choice of the stent and correct implantation (all stents are not equivalent and have different geometrical effects); 6) pharmacological adjuncts; 7) a good team. Recent studies have shown that CAS has superior short-term outcomes than CEA in high surgical risk patients, but there are enough reported data to conclude that CAS is also not inferior to CEA in low-risk patients. CAS under protection is the standard of care and is maybe becoming the gold standard treatment of a carotid stenosis at least in some subgroups of patients.

  10. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito [Kainan Hospital Aichi Prefectural Welfare Federation of Agricultural Cooperatives, Department of Neurosurgery, Aichi (Japan); Miyachi, Shigeru; Hattori, Kenichi [Nagoya University Graduate School of Medicine, Department of Neurosurgery, Nagoya (Japan)

    2006-11-15

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  11. Carotid angioplasty with stenting for chronic internal carotid artery occlusion: technical note

    International Nuclear Information System (INIS)

    Kobayashi, Nozomu; Tanasawa, Toshihiko; Okada, Takeshi; Endo, Otone; Yamamoto, Naohito; Miyachi, Shigeru; Hattori, Kenichi

    2006-01-01

    Carotid angioplasty with stenting (CAS) is becoming accepted as an effective and reliable treatment option for severe carotid artery stenosis. However, it is rarely applied for carotid occlusion, especially in its chronic stage. We report our experience of CAS for chronic internal carotid artery occlusion representing compromised cerebral blood flow using various protection methods. A 77-year-old woman, who was already diagnosed with severe left internal carotid artery stenosis, suddenly had right hemiparesis and aphasia. At that time, she was treated conservatively because her neurological status was quite good, in spite of left carotid artery occlusion. Her symptoms improved in the short term, except slight aphasia, but deteriorated again 18 days from the onset, and magnetic resonance imaging (MRI) showed new ischemic lesions. CAS was then performed for the occluded carotid artery on the 23rd day from the first onset. Using the proximal protection technique, the occluded lesion was crossed carefully with a microguidewire. Stents were also placed successfully with the distal protection technique. The occluded carotid artery was completely recanalized without any unfavorable events or neurological deterioration. In this patient, CAS was successfully to treat chronic carotid artery occlusion. These procedures and techniques are reviewed and discussed. (orig.)

  12. Acute Carotid Artery Stent Thrombosis Due to Dual Antiplatelet Resistance

    International Nuclear Information System (INIS)

    Köklü, Erkan; Arslan, Şakir; Yüksel, İsa Öner; Bayar, Nermin; Koç, Pınar

    2015-01-01

    Carotid artery stenting (CAS) is a revascularization modality that is an alternative to carotid endarterectomy. The efficacy of CAS in primary and secondary prevention from ischemic stroke has been demonstrated in various trials. Acute thrombosis of CAS is a rare complication that can lead to dramatic and catastrophic consequences. We discuss a case of acute CAS thrombosis in a patient who had previously undergone successful CAS. CAS was performed in a 73-year-old man who had had dysarthria lasting 2 weeks with 95 % stenosis in his left internal carotid artery. An acute cerebrovascular event resulting in right-sided hemiplegia developed 24 h after the procedure. Computed tomographic carotid angiography revealed complete occlusion of the stent with thrombus. The cause of stent thrombosis was thought to be antiaggregant resistance to both acetylsalicylic acid and clopidogrel. The most important cause of acute CAS thrombosis is inadequate or ineffective antiaggregant therapy. Evaluating patients who are candidates for CAS for acetylsalicylic acid and clopidogrel resistance may preclude this complication

  13. Carotid artery stenting: Rationale, technique, and current concepts

    International Nuclear Information System (INIS)

    Yilmaz, Hasan; Pereira, Vitor Mendes; Narata, Ana-Paula; Sztajzel, Roman; Lovblad, Karl-Olof

    2010-01-01

    Carotid stenosis is a major risk factor for stroke. With the aging of the general population and the availability of non-invasive vascular imaging studies, the diagnosis of a carotid plaque is commonly made in medical practice. Asymptomatic and symptomatic carotid stenoses need to be considered separately because their natural history is different. Two large randomized controlled trials (RCTs) showed the effectiveness of carotid endarterectomy (CEA) in preventing ipsilateral ischemic events in patients with symptomatic severe stenosis. The benefit of surgery is much less for moderate stenosis and harmful in patients with stenosis less than 50%. Surgery has a marginal benefit in patients with asymptomatic stenosis. Improvements in medical treatment must be taken into consideration when interpreting the results of these previous trials which compared surgery against medical treatment available at the time the trials were conducted. Carotid artery stenting (CAS) might avoid the risks associated with surgery, including cranial nerve palsy, myocardial infarction, or pulmonary embolism. Therefore and additionally to well-established indications of CAS, this endovascular approach might be a valid alternative particularly in patients at high surgical risk. However, trials of endovascular treatment of carotid stenosis have failed to provide enough evidence to justify routine CAS as an alternative to CEA in patients suitable for surgery. More data from ongoing randomized trials of CEA versus CAS will be soon available. These results will help determining the role of CAS in the management of patients with carotid artery stenosis.

  14. Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis

    International Nuclear Information System (INIS)

    Dorresteijn, Lucille; Vogels, Oscar; Leeuw, Frank-Erik de; Vos, Jan-Albert; Christiaans, Marleen H.; Ackerstaff, Rob; Kappelle, Arnoud C.

    2010-01-01

    Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.

  15. Acute hemifacial ischemia as a late complication of carotid stenting

    Directory of Open Access Journals (Sweden)

    Maurizio Domanin, MD

    2017-06-01

    Full Text Available Concerns about carotid artery stenting (CAS center primarily on procedural complications like acute occlusion, stroke, and long-term intrastent restenosis. External carotid artery (ECA thrombosis is observed during CAS follow-up, but it often remains asymptomatic or, at worst, results in jaw claudication. We report here a case of late occlusion of the ECA after CAS with symptoms of acute homolateral facial ischemia as well as pain, cyanosis, tongue numbness, and skin coldness. The patient was submitted to local thrombolysis and balloon angioplasty with regression of symptoms after recanalization. With this report, we add a caveat about blockage of the ECA ostium during CAS.

  16. A suggested training programme for carotid artery stenting (CAS)

    International Nuclear Information System (INIS)

    Gaines, Peter; Nicholson, Tony

    2006-01-01

    Carotid artery stenting as an alternative to traditional carotid endartrectomy is becoming increasingly important in the treatment of transient ischemic attack and stroke. Physicians from several different medical disciplines are interested in treating appropriate patients by this method. Patients are entitled to know what training and experience the surgeon or clinician has before giving consent. This should involve endovascular experience in all systems and experience and knowledge of cerebral angiography and intervention. A multidisciplinary approach and reporting of adverse events is vital for patient safety

  17. Thrombectomy assisted by carotid stenting in acute ischemic stroke management

    DEFF Research Database (Denmark)

    Steglich-Arnholm, Henrik; Holtmannspötter, Markus; Kondziella, Daniel

    2015-01-01

    .0). Early clinical improvement was detected in 22 (46%) patients. Favorable outcome at 3 months occurred in 32 (68%) patients. Expedited patient management was associated with favorable clinical outcome. Two (4%) patients experienced symptomatic hemorrhage. Eight (17%) patients experienced stent thrombosis....... Four (9%) patients died. Thrombectomy assisted by carotid stenting seems beneficial and reasonably safe with a promising rate of favorable outcome. Nevertheless, adverse events and complications call for additional clinical investigations prior to recommendation as clinical standard. Expeditious...... patient management is central to achieve good clinical outcome....

  18. Treatment of carotid artery aneurysms with covered stents; Aneurysmabehandlung der Arteria carotis interna mit gecoverten Stents

    Energy Technology Data Exchange (ETDEWEB)

    Rohr, A.; Alfke, K.; Doerner, L.; Jansen, O. [UKSH Kiel (Germany). Neurochirurgie Neuroradiologie; Bartsch, T.; Stingele, R. [UKSH Kiel (Germany). Neurologie

    2007-10-15

    Purpose: Evaluation of the use of covered stents in treating pseudoaneurysms of the cervical and intracranial/extradural carotid artery and determination of the periprocedural and short- to mid-term complication rate. Materials and Methods: 8 patients with 9 spontaneous dissecting aneurysms of the cervical carotid artery - 5 of which were symptomatic - plus one patient with ofthalmoplegia due to an aneurysm of the cavernous carotid artery were studied. While the latter was treated with a PTFE-covered balloon-mounted stainless steel stent (Jostent/Graftmaster), a self-expanding PTFE-covered Nitonol Stent (Symbiot) was used in all other cases. Intervention was performed with local anesthesia. Aspirin and Clopidogrel were both used as antiplatelet drugs. Clinical signs and symptoms and vascular imaging with DS, MR, CT angiography and ultrasound were recorded during patient follow-up, with a mean follow-up period of 14.6 months (4 - 30). Results: We were able to treat 8 out of 10 aneurysms (80 %) using covered stents. The aneurysms were immediately occluded and the associated stenoses of the parent vessel were eliminated. No clinically relevant complications occurred during the procedure or in the follow-up interval. In two cases, elongation of the carotid artery prevented the stent from being positioned over the aneurysm neck. These cases were shown to be stable with the use of antiplatelet drugs. Conclusion: Covered stents can be used in the treatment of pseudoaneurysms of the carotid artery as an alternative to long-term antithrombotic medication or surgery. In our study treatment was effective (80 %) and free of complications in the short- and mid-term follow-up. Possible indications, technique and the use of imaging modalities for patient follow-up are discussed. (orig.)

  19. Guidelines for patient selection and performance of carotid artery stenting.

    Science.gov (United States)

    Bladin, Christopher; Chambers, Brian; New, Gishel; Denton, Michael; Lawrence-Brown, Michael

    2010-06-01

    The endovascular treatment of carotid atherosclerosis with carotid artery stenting (CAS) remains controversial. Carotid endarterectomy remains the benchmark in terms of procedural mortality and morbidity. At present, there are no consensus Australasian guidelines for the safe performance of CAS. We applied a modified Delphi consensus method of iterative consultation between the College representatives on the Carotid Stenting Guidelines Committee (CSGC). Selection of patients suitable for CAS needs careful consideration of clinical and patho-anatomical criteria and cannot be directly extrapolated from clinical indicators for carotid endarterectomy (CEA). Randomized controlled trials (including pooled analyses of results) comparing CAS with CEA for treatment of symptomatic stenosis have demonstrated that CAS is more hazardous than CEA. On current evidence, the CGSC therefore recommends that CAS should not be performed in the majority of patients requiring carotid revascularisation. The evidence for CAS in patients with symptomatic severe carotid stenosis who are considered medically high risk is weak, and there is currently no evidence to support CAS as a treatment for asymptomatic carotid stenosis. The use of distal protection devices during CAS remains controversial with increased risk of clinically silent stroke. The knowledge requirements for the safe performance of CAS include an understanding of the evidence base from randomized controlled trials, carotid and aortic arch anatomy and pathology, clinical stroke syndromes, the differing treatment options for stroke and carotid atherosclerosis, and recognition and management of periprocedural complications. It is critical that all patients being considered for a carotid intervention have adequate pre-procedural neuro-imaging and an independent, standardized neurological assessment before and after the procedure. Maintenance of proficiency in CAS requires active involvement in surgical/endovascular audit and

  20. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  1. Efficacy of Carotid Artery Stenting by the Universal Protection Method.

    Science.gov (United States)

    Goto, Shunsaku; Ohshima, Tomotaka; Kato, Kyozo; Izumi, Takashi; Wakabayashi, Toshihiko

    2018-04-18

    To avoid distal plaques embolization during carotid artery stenting, we developed Universal Protection Method that combined the use of a proximal common carotid artery balloon, an external carotid artery balloon, and a distal internal carotid artery filter, with continuous flow reversal to the femoral vein. Herein, we assessed the efficacy of the Universal Protection Method by comparing stenting outcomes before and after its introduction. We assessed outcomes for 115 cases before and 41 cases after the Universal Protection Method was adopted (non-Universal Protection Method and Universal Protection Method groups, respectively). We then compared procedure details, magnetic resonance imaging (within 48 hours after the procedure), intraprocedural complications, and postoperative stroke rates. Ischemic stroke was not observed in the Universal Protection Method group, but 1 major stroke and 2 minor strokes were observed in the non-Universal Protection Method group. High-intensity areas were seen in 6 (15.0%) and 49 (42.6%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively (P = .001). Contrastingly, intraprocedural complications were observed in 9 (22.5%) and 21 (18.3%) cases in the Universal Protection Method and non-Universal Protection Method groups, respectively. Among these intraprocedural complication cases, high-intensity areas were observed in 1 case (11.1%) in the Universal Protection Method group and in 15 cases (71.4%) in the non-Universal Protection Method group. Universal Protection Method is a safe technique that is applicable to all patients undergoing carotid artery stenting, irrespective of individual risk factors. Notably, the incidence rates of both distal embolization and unexpected intraprocedural complications are low. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. Early outcomes after carotid angioplasty with stenting performed by neurologists

    Directory of Open Access Journals (Sweden)

    Bathala Lokesh

    2010-01-01

    Full Text Available Aims: To evaluate the results of carotid artery angioplasty and stenting (CAS in treating extracranial carotid artery stenosis performed by neurologists in our center and compare the results with other large published series. Materials and Methods: Data for all patients who underwent CAS from January 2003 through November 2007, was retrieved from the Nanjing Stroke Registry. Perioperative and post-procedural complications within 30 days following stenting were analyzed and compared with that from other series. A total number of 75 patients were enrolled, with a mean age of 65.9 ± 8.8 years, and 64 (85.3% of them were male. Results: Procedural success was achieved in 74 patients (98.7%. Pre-treatment stenosis was 73.8 ± 14.9 and post-treatment residual stenosis was less than 10%. Thirty-four patients (45.3% had bilateral carotid artery disease and seven (9.3% had tandem stenosis. The neurological complication rate was 3.9% (one major and two minor strokes. Bradycardia in four (5.3% and hypotension in 13 (17.3% were observed during procedures. Using the Fischer′s exact t test, the complication rate compared with the large published series did not reveal any statistically significant difference (P > 0.05. Conclusions: We conclude that neurologists, with adequate training, can develop and add this technical skill to the existing cognitive skill of vascular neurology and safely perform stenting.

  3. Carotid angioplasty and stent placement for restenosis after endarterectomy

    International Nuclear Information System (INIS)

    Kadkhodayan, Yasha; Moran, Christopher J.; Cross, DeWitte T.; Derdeyn, Colin P.

    2007-01-01

    Recurrent carotid stenosis following endarterectomy is a common complication, and reoperation may be associated with increased morbidity. The goal of this study was to determine the procedural safety and long-term complication rates of carotid angioplasty and stenting for recurrent stenosis. Of 248 consecutive carotid angioplasty and/or stenting procedures performed at our institution between March 1996 and November 2005, 83 procedures for recurrent stenosis following endarterectomy were performed in 75 patients (mean age 68 years; 43 men, 32 women) without cerebral protection devices. The patients' medical records were retrospectively reviewed for vascular imaging reports and available clinical follow-up. Procedural and long-term complication rates were calculated. Recurrent stenosis was reduced from a mean of 80.6% to no significant stenosis in 82 of 83 procedures. The procedural stroke rate was 3 out of 83 procedures (3.6%). The procedural transient ischemic attack (TIA) rate was 2 out of 83 procedures (2.4%). Mean follow-up was 22.4 months (range 0.1 to 86.7 months) with at least 6 months follow-up for 54 of 83 procedures (65%). There were five TIAs and no strokes on follow-up (new TIAs at 25.5 and 43.4 months; recurrent TIAs at 1, 11.1, and 12 months, all with normal angiograms). The composite 30-day stroke, myocardial infarction, or death rate was 5 of 83 procedures (6.0%). In this series, angioplasty and stenting were effective in relieving stenosis secondary to recurrent carotid disease after endarterectomy, and have low rates of ischemic complications. (orig.)

  4. Effect of white-matter lesions on the risk of periprocedural stroke after carotid artery stenting versus endarterectomy in the International Carotid Stenting Study (ICSS): a prespecified analysis of data from a randomised trial

    NARCIS (Netherlands)

    Ederle, J.; Davagnanam, I.; Worp, H.B. van der; Venables, G.S.; Lyrer, P.A.; Featherstone, R.L.; Brown, M.M.; Jager, H.R.; Leeuw, F.E. de; Schultze Kool, L.J.; Vliet, J.A. van der; et al.,

    2013-01-01

    BACKGROUND: Findings from randomised trials have shown a higher early risk of stroke after carotid artery stenting than after carotid endarterectomy. We assessed whether white-matter lesions affect the perioperative risk of stroke in patients treated with carotid artery stenting versus carotid

  5. Analysis of emboli during carotid stenting with distal protection device.

    Science.gov (United States)

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p protection device, 7,395 emboli with 42% solids were detected (p protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  6. Complications in percutaneous transluminal stenting for carotid artery stenosis

    International Nuclear Information System (INIS)

    Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng

    2007-01-01

    Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)

  7. In-stent restenosis of innominate artery with critical stenosis of right internal carotid artery

    International Nuclear Information System (INIS)

    Hussain, S.; Raza, A.; Ahmed, W.

    2011-01-01

    A lady with aortitis syndrome developed in-stent restenosis (ISR) of the innominate artery stent and critical stenosis of right internal carotid artery. The therapeutic challenge was gaining access to the carotid vessel, after treating the innominate artery ISR and all the while using distal protection to circumvent potential cerebral embolism. Percutaneous transluminal angioplasty (PTA) with or without stenting is a safe therapeutic option for re-vascularization of the supra aortic vessels. In the event of re-stenosis, re-treatment with PTA and stenting is safe. Ample evidence-base exists now for carotid artery stenting (CAS) in preference to carotid endarterectomy in patients with stenotic lesions of the carotid vessels. (author)

  8. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  9. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  10. [Current guidelines on carotid artery stenting. Critical evaluation].

    Science.gov (United States)

    Hein-Rothweiler, R; Mudra, H

    2013-11-01

    Scientific data underlying current guidelines on treatment of carotid artery stenosis is subject to interdisciplinary discussion. In particular selective weighting of the randomized European studies leads to conflicting levels of recommendation and levels of evidence, especially when directly comparing guidelines under surgical versus endovascular guidance. Surgical guidelines recommend a limitation of carotid artery stenting (CAS) to symptomatic patients with specific surgical/anatomical disadvantages and/or severe comorbidities. The European Society of Cardiology (ESC) guidelines recommend the use of CAS only in patients at increased surgical risk but at the same time requires morbidity and mortality rates comparable to those of surgical interventions. Even one step further, the American guidelines and specifically the associated comments of the German Society of Cardiology on the above mentioned ESC guidelines put CAS and carotid endarterectomy (CEA) on a par in terms of treatment alternatives, presupposing analogous CEA complication rates. Differential interpretation of the so far inadequate data is a common issue of current evidence-based medicine. The difficulty in conceptualization of new studies concerning the therapy of carotid stenosis lies in the funding these large projects and also on the high patient number required to achieve adequate statistical power. Furthermore, during the estimated long study period substantial changes of current techniques and devices can be anticipated which might render the study results in part outdated by the time of publication. However, as long as no new randomized study results comparing medical, surgical and interventional treatment of carotid stenosis are available, the question on the optimal therapy for patients with carotid artery disease remains unanswered.

  11. Perspective: carotid stenting and the history of disruptive technology in vascular surgery.

    Science.gov (United States)

    Veith, Frank J

    2008-06-01

    This article defines disruptive technology and discusses such technologies in Vascular Surgery. It considers the question: Is carotid artery stenting (CAS) a disruptive technology? Although CAS will impact positively on the treatment of carotid bifurcation disease, it will probably never displace carotid endarterectomy in the majority of patients. The precise role of CAS remains to be determined.

  12. Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection.

    Science.gov (United States)

    Harada, Kei; Kakumoto, Kosuke; Oshikata, Shogo; Fukuyama, Kozo

    2018-06-01

    Carotid artery stenting (CAS) with proximal occlusion effectively prevent distal cerebral embolism by flow arrest at internal carotid artery (ICA); however, the method can expose antegrade flow at ICA due to incomplete flow arrest. The aim of this study was to identify predictors of antegrade flow during CAS with proximal protection. We retrospectively analyzed clinical and angiographic data among 143 lesions treated with CAS with proximal protection by occluding the common carotid artery (CCA) and external carotid artery (ECA). Flow arrest or antegrade flow at ICA was confirmed by contrast injection during proximal protection. Antegrade flow at ICA was observed in 12 lesions (8.4%). Compared with lesions in which flow arrest of ICA was achieved, the diameter of the superior thyroid artery (STA) was significantly larger (2.4 ± 0.34 vs. 1.4 ± 0.68 mm, p protection should be combined with proximal protection for the lesions with antegrade flow to prevent distal migration of the carotid debris.

  13. Stent-induced flow disturbances in the ipsilateral external carotid artery following internal carotid artery stenting: a temporary cause of jaw claudication.

    Science.gov (United States)

    Giurgea, Georgiana-Aura; Haumer, Markus; Mlekusch, Irene; Sabeti-Sandor, Schila; Dick, Petra; Schillinger, Martin; Minar, Erich; Mlekusch, Wolfgang

    2017-07-01

    We hypothesize that stenting of the internal carotid artery can immediately impede blood flow to the external carotid artery by either plaque shift or stent coverage of the ostium, and thereby cause ischemic symptoms like ipsilateral jaw claudication. Thirty-three patients with high-grade asymptomatic stenosis of the internal carotid artery who underwent endovascular treatment were examined by ultrasound of the external carotid artery and performed an exercise test by chewing chewing gum synchronously to an electronic metronome for 3 min. Tests were performed before, the day after, and 1 week after the stenting procedure. Claudication time was defined as the timespan until occurrence of pain of the masseter muscle and/or chewing dyssynchrony to the metronome for more than 15 s. Ten patients with an isolated, atherosclerotic stenosis of the external carotid artery served as controls. A significantly reduced claudication time (in seconds) was recorded in patients who underwent carotid artery stenting compared to baseline values; median 89 (interquartile range, IQR, 57 to 124) vs. median 180 (IQR 153 to 180; p external carotid artery into faster or slower as 200 cm/sec, the effect was even accentuated. Stenting values showed improvement 1 week after but did not return to baseline levels. No respective changes were found in controls. Stenting of the internal carotid artery lead to ipsilateral flow deterioration at the external carotid artery resulting in temporary jaw claudication. This impairment attenuated over the time and was significantly reduced after 1 week.

  14. Usefulness of CT angiography after metallic stent implantation of the internal carotid artery

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyeon Chul; Kim, Jae Kyu; Seo, Jeong Jin; Jeong, Gwang Woo; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of CT angiography in patients with implantation of metallic stent for stenosed internal carotid artery. Seven patients with atherosclerotic stenosis of the internal carotid artery underwent metallic stent implantation. All were male and their ages ranged from 36 to 69 years. A total of seven stents were placed in the internal carotid artery in five patients and in the carotid bifurcation in two. Spiral CT scans were obtained and CT angiographic images were reconstructed using MPR or curved MPR techniques at a workstation. The interval between CT and conventional angiography did not exceed six days except in one patient, in whom it was 61days. CT and conventional angiography were compared for stent position with respect to the carotid bifurcation, stent deformation, intraluminal filling defect, and luminal caliber and outflow. Luminal patency of the implanted stent was measured according to NASCET(North American Symptomatic Carotid Endarterectomy Trial) criteria, and statistically processed (p>.05). The presence or absence of intrastent thrombus and vascular wall calcification was determined using axial source images. In all patients, CT angiographic findings matched those obtained by conventional angiography. Complications such as migration or deformation of an implanted stent, intraluminal filling defect, change of luminal caliber or outflow of implanted stent were not observed in any patient. In two studies in which Wilcoxon signed rank test was used, degree of stent expansion correlated closely(p=0.237). Axial source images showed that in no patient was an intrastent thrombus present, though in five, vascular wall calcification of internal carotid arteries outside the stent was noted. CT angiography is useful for the assessment of positional change, occlusion, and luminal patency of a stent-implanted internal carotid artery

  15. Novel 3D-CT evaluation of carotid stent volume: greater chronological expansion of stents in patients with vulnerable plaques.

    Science.gov (United States)

    Itami, Hisakazu; Tokunaga, Koji; Okuma, Yu; Hishikawa, Tomohito; Sugiu, Kenji; Ida, Kentaro; Date, Isao

    2013-09-01

    Although self-expanding carotid stents may dilate gradually, the degrees of residual stenosis have been quantified by the NASCET criteria, which is too simple to reflect the configuration of the stented artery. We measured the volumes of the stent lumens chronologically by 3D-CT in patients after carotid artery stenting (CAS), and analyzed the correlations between the volume change and medical factors. Fourteen patients with carotid artery stenosis were treated using self-expanding, open-cell stents. All patients underwent preoperative plaque MRI (magnetization-prepared rapid acquisition gradient-echo, MPRAGE) and chronological 3D-CT examinations of their stents immediately after their placement and 1 day, 1 week, and 1 month after the procedure. The volume of the stent lumen was measured using a 3D workstation. The correlations between stent volume and various factors including the presence of underlying diseases, plaque characteristics, and the results of the CAS procedure were analyzed. Stent volume gradually increased in each case and had increased by 1.04-1.55 (mean, 1.25)-fold at 1 postoperative month. The presence of underlying medical diseases, plaque length, the degree of residual stenosis immediately after CAS, and plaque calcification did not have an impact on the change in stent volume. On the other hand, the stent volume increase was significantly larger in the patients with vulnerable plaques that demonstrated high MPRAGE signal intensity (P stent volume. Self-expanding stents in carotid arteries containing vulnerable plaques expand significantly more than those without such plaques in a follow-up period.

  16. Continuous Blood Glucose Monitoring May Detect Carotid Occlusion Intolerance during Carotid Artery Stenting.

    Science.gov (United States)

    Hiramatsu, Ryo; Furuse, Motomasa; Yagi, Ryokichi; Ohmura, Tomohisa; Ohnishi, Hiroyuki; Ikeda, Naokado; Nonoguchi, Naosuke; Kawabata, Shinji; Miyachi, Shigeru; Kuroiwa, Toshihiko

    2018-02-05

    The frequency of the occurrence of adverse events associated with carotid artery stenting (CAS) is usually low, but serious adverse events such as cerebral hyperperfusion syndrome (CHS) may occur. Real-time monitoring is ideal for the early detection of adverse events during the surgical procedure. This study aimed to evaluate continuous blood glucose (BG) monitoring for the detection of adverse events during CAS. Forty patients undergoing scheduled CAS were prospectively enrolled. An artificial pancreas was used for continuous BG monitoring (once per minute), using venous blood extracted at a rate of 2 mL/hr during CAS. The primary endpoint was a correlation between BG change and adverse events. CAS was discontinued in 1 patient, and BG was not measured in 5 patients (12.5%) because of the inability to extract blood. Among 34 evaluable patients, no patient developed CHS, but 3 patients (9%) experienced carotid occlusion intolerance. During CAS, BG was significantly higher in patients with carotid occlusion intolerance (median: 5 mg/dL) than in patients without carotid occlusion intolerance (median: 0 mg/dL) (P = 0.0221). A cutoff BG value ≥4 mg/dL during CAS showed 50% sensitivity and 100% specificity for the detection of carotid occlusion intolerance. There was no significant correlation between BG change and other adverse events. BG elevation may help detect carotid occlusion intolerance although it is still unknown whether BG monitoring can detect CHS. Further studies should validate that a cutoff BG elevation value of ≥4 mg/dL during CAS indicates carotid occlusion intolerance. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Stent impact on the geometry of the carotid bifurcation and the course of the internal carotid artery

    International Nuclear Information System (INIS)

    Berkefeld, J.; Zanella, F.E.; Rosendahl, H.; Theron, J.G.; Guimaraens, L.; Treggiari-Venzi, M.M.

    2002-01-01

    A measurement system is proposed to evaluate reconstructive effects of carotid stents on the geometry of the carotid bifurcation and the course of the internal carotid artery. To describe deviations of the stenotic internal carotid artery (ICA) from the extended axis of the common carotid artery (CCA) the CCA-ICA angle is measured between the CCA midaxis and the midaxis of the stenotic ICA segment. Maximal extensions of ICA tortuosities perpendicular to the course of the CCA axis are defined as ICA offset. The measurements were applied to DSA images of 224 carotid stenoses to evaluate variation and correlation between the two parameters. Comparative pre- and post-stent evaluation was performed in two series of 55 and 31 carotid stenoses treated with Wallstents and in a historic control group of 35 stenoses treated with Strecker stents. Straight course of the ICA was associated with low angle and low offset values, whereas tortuous course of the ICA showed larger angle and offset. A moderate linear correlation between the two parameters was found. Corresponding to a straightening of the stented segment, Wallstents reduced mean angle and offset values significantly. In five cases of the second series of Wallstents, transferrals of curves above the distal stent end associated with kinks were observed, and offset remained constant or increased. Strecker stent implantation caused no significant changes of bifurcational geometry. The proposed parameters corresponded to visual aspects of ICA tortuosity and detected reconstructive effects of self-expanding Wallstents on the ICA course. The measurement system may provide a basis for geometric evaluation of different stent types or implantation concepts with the aim: to optimize anatomic recanalization results in tortuous high angle-high offset bifurcations. (orig.)

  18. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  19. Focal ischemia of the brain after neuroprotected carotid artery stenting.

    Science.gov (United States)

    Schlüter, Michael; Tübler, Thilo; Steffens, Johann C; Mathey, Detlef G; Schofer, Joachim

    2003-09-17

    This study sought to assess the incidence of cerebral ischemia in nonselected patients undergoing neuroprotected carotid angioplasty and stenting (CAS) without preceding multiple-vessel diagnostic angiography. Protection devices to prevent distal embolization during CAS are presently under clinical investigation. Diffusion-weighted magnetic resonance imaging (MRI) visualizes recent ischemia of the brain and may aid in assessing the efficacy of protection devices. Elective CAS was performed in 42 consecutive patients (15 female, 27 male; mean age, 67 +/- 9 years) using six different types of cerebral protection systems. All patients underwent MRI of the brain before and after a total of 44 interventions. Placement and retrieval of the devices and stent deployment was achieved in all procedures. New ischemic foci were seen on postinterventional MRI in 10 cases (22.7%). One patient had sustained a major stroke, whereas no adverse neurological sequelae were associated with the other nine procedures. In the latter, one to three foci (maximum area 43.0 mm(2)) were detected in cerebral regions subtended by the ipsilateral carotid artery in eight cases and by the contralateral carotid artery in one case. In the stroke patient, 12 ischemic foci (maximum area 84.5 mm(2)) were exclusively located in the contralateral hemisphere. Follow-up MRI at 4.1 months (median, n = 7) identified residuals of cerebral ischemia only in this patient. Neuroprotected CAS is associated in about 25% of cases with predominantly silent cerebral ischemia. Our findings suggest manipulation of endoluminal equipment in the supraaortic vessels to be a major risk factor for cerebral embolism during neuroprotected CAS.

  20. Spasm induced by protection balloon during carotid artery stenting

    International Nuclear Information System (INIS)

    Tsutsumi, Masanori; Kazekawa, Kiyoshi; Onizuka, Masanari

    2007-01-01

    The PercuSurge system is a distal balloon embolic protection device used for carotid artery stenting (CAS). We performed a retrospective study on the prognosis and clinical effects of spasms induced by the PercuSurge GuardWire system (PercuSurge-induced spasm). We performed CAS in 118 carotid stenoses using the PercuSurge system. Of the 118 procedures, 31 (26.3%) of the patients experienced PercuSurge-induced spasm, and all underwent postoperative follow-up studies by cerebral angiography and antiplatelet treatment. On follow-up angiograms obtained a mean of 5.2 months (range 3-10 months) after CAS, all 31 PercuSurge-induced spasms had disappeared, and no delayed stenosis was found at the sites where the spasms had occurred. No ischemic events due to the spasms occurred during a mean follow-up of 13 months (range 3-32 months). In the hands of physicians experienced in endovascular surgery, CAS using the PercuSurge system is a safe method with which to treat patients with carotid stenosis. Our study demonstrated that PercuSurge-induced spasms had no morphological or clinical adverse effects. (author)

  1. Complications and Follow-up after Unprotected Carotid Artery Stenting

    International Nuclear Information System (INIS)

    Hauth, Elke A.M.; Drescher, Robert; Jansen, Christian; Gissler, H. Martin; Schwarz, Michael; Forsting, Michael; Jaeger, Horst J.; Mathias, Klaus D.

    2006-01-01

    Purpose. This prospective study was undertaken to determine the success rate, complications, and outcome of carotid artery stenting (CAS) without the use of cerebral protection devices. Methods. During 12 months, 94 high-grade stenoses of the carotid artery in 91 consecutive patients were treated. Sixty-six (70%) of the stenoses were symptomatic and 28 (30%) were asymptomatic. Results. In all 94 carotid stenoses CAS was successfully performed. During the procedure and within the 30 days afterwards, there were 2 deaths and 3 major strokes in the 66 symptomatic patients, resulting in a combined death and stroke rate of 5 of 66 (7%). Only one of these complications, a major stroke, occurred during the procedure. In the 6-month follow-up, one additional major stroke occurred in a originally symptomatic patient resulting in a combined death and stroke rate of 6 of 66 (10%) for symptomatic patients at 6 months. No major complications occurred in asymptomatic patients during the procedure or in the 6-month follow-up period. At 6 months angiographic follow-up the restenosis rate with a degree of >50% was 3 of 49 (6%) and the rate with a degree of ≥70% was 1 of 49 (2%). Conclusions. Cerebral embolization during CAS is not the only cause of the stroke and death rate associated with the procedure. The use of cerebral protection devices during the procedure may therefore not prevent all major complications following CAS

  2. Flow Velocities After Carotid Artery Stenting: Impact of Stent Design. A Fluid Dynamics Study in a Carotid Artery Model with Laser Doppler Anemometry

    International Nuclear Information System (INIS)

    Greil, Oliver; Kleinschmidt, Thomas; Weiss, Wolfgang; Wolf, Oliver; Heider, Peter; Schaffner, Silvio; Gianotti, Marc; Schmid, Thomas; Liepsch, Dieter; Berger, Hermann

    2005-01-01

    Purpose. To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. Methods. Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 μm. All stents were deployed across the bifurcation and the external carotid artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. Results. The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. Conclusions. Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow

  3. Comparisons of carotid artery stenting and carotid endoarterectomy in terms of diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Mitsuoka, Hiroshi; Shintani, Tsunehiro; Masuda, Mikio; Higashi, Shigeki

    2009-01-01

    The objective of this study was to compare two methods of treatment for carotid arterial stenosis, carotid endarterectomy (CEA) and carotid artery stenting (CAS), by means of diffusion-weighted MR imaging (DWI). Nineteen treatments in 18 cases during the 2007 academic year were included in this study. CAS was performed for 9 cases with 10 lesions (10 procedures), while 9 cases with 9 lesions (9 procedures) were treated by CEA. Patients were examined by a neurologist before and after the procedure, and had pre- and post-procedural DWI. No strokes or transient ischemic attacks (TIAs) were observed in these cases. New DWI lesions were found in 7 out of the 10 procedures of CAS imaged 24 hours postprocedure, (average: 2.0 lesions). No new lesions were detected on DWI of CEA cases (χ 2 =8.33, p=0.0039). Certain high-risk subsets may respond well to CAS with a very low incidence of clinically-evident neurologic events, but with significantly higher incidence of periprocedural micro-brain embolism. Currently, CEA should be the first choice of treatment for atherosclerotic carotid artery stenosis. (author)

  4. Safety of Carotid Artery Stenting in Elderly Patients with Severe Carotid Artery Stenosis

    International Nuclear Information System (INIS)

    Choi, Seul Kee; Kim, Seul Kee; Jeong, Min Young; Yoon, Woong

    2012-01-01

    To determine the safety of carotid artery stenting (CAS) using an emboli-protection device in elderly patients with severe carotid artery stenosis. Ninety consecutive patients who were at high risk for carotid endarterectomy underwent protected CAS using an emboli-protection device. Patients were divided into two groups by age: < 70 and ≥ 70. The primary outcome measure was the combined incidence of stroke, myocardial infarction (MI), and death within 30 days of CAS. The secondary outcome measures were technical success and hyperperfusion syndrome. Associations between age and the clinical outcomes were investigated. Overall, 30-day stroke, MI, and death rates were 6.7%. There was no significant difference in the primary outcome between the older age group (n = 56) and younger age group (n = 34) (8.9% and 2.9%, respectively; HR for age ≥ 70, 1.141; 95% CI, 0.875 to 1.488, p = 0.331). A logistic regression showed there was no independent variable associated with primary outcome. Technical success was achieved in all patients and there was no significant difference in the incidence of hyperperfusion syndrome between the two age groups. The results of this study suggest that protected CAS seems to be safe in elderly patients with severe carotid artery stenosis.

  5. Influence of carotid artery stenting on cognitive function

    Energy Technology Data Exchange (ETDEWEB)

    Quasar Grunwald, Iris [Saarland University Clinic, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Department of Neuroradiology, Homburg (Germany); Papanagiotou, Panagiotis; Backens, Martin; Politi, Maria; Vedder, Verena; Zercher, K. [Saarland University Clinic, Department for Diagnostic and Interventional Neuroradiology, Homburg (Germany); Reith, Wolfgang; Supprian, Tilman; Muscalla, B.; Haass, Anton; Krick, Christoph M. [Saarland University Clinic, Clinic for Neurology, Homburg (Germany); Saarland University Clinic, Clinic for Psychiatry and Psychotherapy, Homburg (Germany)

    2010-01-15

    There have only been a few studies on cognitive changes in patients with carotid occlusive disease, and the results of these show major discrepancies in the extent to which treatment affects neuropsychological function. We sought to clarify these discrepancies by evaluating the effects of carotid artery stenting (CAS) on the cognitive function. Forty-one asymptomatic CAS patients were administered a test battery of neuropsychological tests measuring cognitive speed and memory function before and 3 months after the procedure. A control group was also evaluated. To test for thromboembolic lesions, diffusion-weighted imaging was used. CAS led to a significant increase in cognitive speed (p < 0.001) but did not afford any change in memory function. This was regardless of the degree or side of stenosis or patient age or gender. CAS significantly improved functions that involve cognitive speed. Earlier studies did not differentiate between speed and memory tests and thus might have missed these changes. Further studies correlating changes in brain perfusion with increase in cognitive speed are needed. (orig.)

  6. Influence of carotid artery stenting on cognitive function

    International Nuclear Information System (INIS)

    Quasar Grunwald, Iris; Papanagiotou, Panagiotis; Backens, Martin; Politi, Maria; Vedder, Verena; Zercher, K.; Reith, Wolfgang; Supprian, Tilman; Muscalla, B.; Haass, Anton; Krick, Christoph M.

    2010-01-01

    There have only been a few studies on cognitive changes in patients with carotid occlusive disease, and the results of these show major discrepancies in the extent to which treatment affects neuropsychological function. We sought to clarify these discrepancies by evaluating the effects of carotid artery stenting (CAS) on the cognitive function. Forty-one asymptomatic CAS patients were administered a test battery of neuropsychological tests measuring cognitive speed and memory function before and 3 months after the procedure. A control group was also evaluated. To test for thromboembolic lesions, diffusion-weighted imaging was used. CAS led to a significant increase in cognitive speed (p < 0.001) but did not afford any change in memory function. This was regardless of the degree or side of stenosis or patient age or gender. CAS significantly improved functions that involve cognitive speed. Earlier studies did not differentiate between speed and memory tests and thus might have missed these changes. Further studies correlating changes in brain perfusion with increase in cognitive speed are needed. (orig.)

  7. Rapid Formation of Cerebral Microbleeds after Carotid Artery Stenting

    Directory of Open Access Journals (Sweden)

    Kousuke Kakumoto

    2012-03-01

    Full Text Available Background: Recent studies reported that cerebral microbleeds (CMBs, i.e. small areas of signal loss on T2*-weighted gradient-echo (GE imaging, could develop rapidly after acute ischemic stroke. We hypothesized that CMBs rapidly emerge after carotid artery stenting (CAS. Objective: We investigated the frequency of and predisposing factors for CMBs after CAS. Methods: We retrospectively examined MRI before and after CAS in 88 consecutive patients (average age: 71.7 ± 7.2 years, average rates of carotid stenosis: 72.6 ± 12.8% who underwent CAS for carotid artery stenosis between March 1, 2009, and September 30, 2010. We defined new CMBs as signal losses that newly appeared on the follow-up GE. We examined the association of new CMBs with demographics, risk factors, and baseline MBs. Results: Among 88 patients, 18 (20.5% had CMBs initially, and 7 (8.0% developed new CMBs right after CAS. New CMBs appeared on the same side of CAS in all of the 7 patients. New CMBs appeared significantly more frequently in the CMB-positive group than in the CMB-negative one (22% vs. 4%, p = 0.03 on the pre-CAS MRI. Multivariate analysis also revealed that the presence of CMBs before CAS was an independent predictor of new development of CMBs after CAS (odds ratio: 8.09, 95% confidence interval: 1.39–47.1. Conclusion: CMBs can develop rapidly after CAS, especially in patients with pre-existing CMBs. Since the existence of CMBs prior to CAS suggests a latent vascular damage which is vulnerable to hemodynamic stress following CAS, particular attention should be paid to the prevention of intracerebral hemorrhage due to hyperperfusion after CAS.

  8. Stent-assisted coil embolization for cavernous carotid artery aneurysms.

    Science.gov (United States)

    Kono, Kenichi; Shintani, Aki; Okada, Hideo; Tanaka, Yuko; Terada, Tomoaki

    2014-01-01

    Internal carotid artery (ICA) occlusion with or without a bypass surgery is the traditional treatment for cavernous sinus (CS) aneurysms with cranial nerve (CN) dysfunction. Coil embolization without stents frequently requires retreatment because of the large size of CS aneurysms. We report the mid-term results of six unruptured CS aneurysms treated with stent-assisted coil embolization (SACE). The mean age of the patients was 72 years. The mean size of the aneurysms was 19.8 mm (range: 13-26 mm). Before treatment, four patients presented with CN dysfunction and two patients had no symptoms. SACE was performed under local or general anesthesia in three patients each. Mean packing density was 29.1% and tight packing was achieved. There were no neurological complications. CN dysfunction was cured in three patients (75%) and partly resolved in one patient (25%). Transient new CN dysfunction was observed in two patients (33%). Clinical and imaging follow-up ranged from 6 to 26 months (median: 16 months). Recanalization was observed in three patients (50%; neck remnant in two patients and dome filling in one patient), but no retreatment has yet been required. No recurrence of CN dysfunction has occurred yet. In summary, SACE increases packing density and may reduce requirement of retreatment with an acceptable cure rate of CN dysfunction. SACE may be a superior treatment for coiling without stents and be an alternative treatment of ICA occlusion for selected patients, such as older patients and those who require a high-flow bypass surgery or cannot receive general anesthesia.

  9. Comparison of closed-cell and hybrid-cell stent designs in carotid artery stenting: clinical and procedural outcomes

    Directory of Open Access Journals (Sweden)

    Ersan TatlI

    2017-05-01

    Full Text Available Introduction: Carotid artery stenting (CAS is a promising alternative to surgery in high-risk patients. However, the impact of stent cell design on outcomes in CAS is a matter of continued debate. Aim : To compare the periprocedural and clinical outcomes of different stent designs for CAS with distal protection devices. Material and methods : All CAS procedures with both closed- and hybrid-cell stents performed at our institution between February 2010 and December 2015 were analyzed retrospectively. Adverse events were defined as death, major stroke, minor stroke, transient ischemic attack and myocardial infarction. Periprocedural and 30-day adverse events and internal carotid artery (ICA vasospasm rates were compared between the closed-cell and hybrid-cell stent groups. Results : The study included 234 patients comprising 146 patients with a closed-cell stent (Xact stent, Abbott Vascular (mean age: 68.5 ±8.6; 67.1% male and 88 patients with a hybrid-cell stent (Cristallo Ideale, Medtronic (mean age: 67.2 ±12.8; 68.2% male. There was no significant difference between the groups with respect to periprocedural or 30-day adverse event rates. While there was no difference in terms of tortuosity index between the groups, there was a higher procedural ICA vasospasm rate in the closed-cell stent group (35 patients, 23% compared with the hybrid-cell stent group (10 patients, 11% (p = 0.017. Conclusions : The results of this study showed no significant difference in the clinical adverse event rates after CAS between the closed-cell stent group and the hybrid-cell stent group. However, procedural ICA vasospasm was more common in the closed-cell stent group.

  10. Carotid Artery Stenting in a Patient with Spontaneous Recanalization of a Proximal Internal Carotid Artery Occlusion: a Case Report

    International Nuclear Information System (INIS)

    Kim, Eui Jong; Koh, Jun Seok; Choi, Woo Suk

    2006-01-01

    We report here on a rare case of carotid artery angioplasty and stenting in a patient with spontaneous recanalization after complete occlusion of the proximal internal carotid artery (ICA). The patient initially showed severe stenosis at the left proximal ICA on MR angiography (MRA). Digital subtraction angiography (DSA) performed three days after MRA showed complete occlusion of the proximal ICA. The follow-up DSA after four weeks showed recanalization of the ICA, and then carotid artery stenting was successfully performed. There has been no neurologic complication during more than one year follow-up. cute internal carotid artery (ICA) occlusions may result in profound disability and death (1). An occluded ICA can spontaneously recanalize, but this doesn't happen frequently, and the natural course of a proximal ICA occlusion and its possibility of recanalization, including the exact time of recanalization after occlusion, are not well known (2, 3). A few studies have reported the incidence of spontaneous recanalization of the proximal internal carotid artery, which has mostly occurred in patients with ICA dissections (4 6). A few limited studies have reported a considerable incidence of spontaneous recanalization in patients with underlying atherosclerotic lesion or atherothombotic diseases (2). The possibility of repeated occlusion and repeated cerebral ischemic infarction may exist for the patients exhibiting spontaneous recanalization of the ICA and underlying atherosclerosis. We report here on a case of carotid artery stenting (CAS) in a patient who exhibited underlying atherosclerosis with spontaneous recanalization after complete occlusion of the proximal ICA

  11. Complication rate in unprotected carotid artery stenting with closed-cell stents

    International Nuclear Information System (INIS)

    Tietke, Marc W.K.; Kerby, Tina; Alfke, Karsten; Riedel, Christian; Rohr, Axel; Jensen, Ulf; Jansen, Olaf; Zimmermann, Phillip; Stingele, Robert

    2010-01-01

    The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable. (orig.)

  12. Investigation into drivers of cost of stenting for carotid stenosis.

    Science.gov (United States)

    Rinaldo, Lorenzo; Brinjikji, Waleed; Cloft, Harry; DeMartino, Randall R; Lanzino, Giuseppe

    2017-09-01

    We aimed to identify factors associated with cost of carotid artery stenting (CAS). Patient and hospital characteristics affecting cost of admission for CAS were identified using the Vizient national database of hospital-reported outcomes. Patients who underwent CAS for either asymptomatic or symptomatic carotid stenosis were identified using surgical Medicare Severity-Diagnosis Related Groups and appropriate International Classification of Diseases, Ninth Revision and Tenth Revision codes. There were 166 hospitals that reported outcomes from 7369 inpatient admissions for CAS. Each institution reported a mean value for cost related to patient care per admission for CAS; the average cost across all reporting institutions was $12,834.14 (standard error of the mean [SEM], 492.88). Institutions in the lowest 25th percentile with respect to frequency of intensive care unit admission after CAS had lower cost of admission than institutions above the 75th percentile ($10,971.30 [SEM, 460.67] vs $14,992.90 [964.29]; P = .002), without any differences in incidence of stroke during admission (2.2% [SEM, 0.3] vs 2.0% [0.4]; P = .877) or 30-day readmission (1.9% [SEM, 0.4] vs 2.5 [0.6]; P = .329). Admissions for patients with symptomatic stenosis were more expensive than those with asymptomatic stenosis ($20,462.10 [SEM, 819.93] vs $11,285.20 [347.11]; P costs of admission ($14,176.20 [SEM, 597.13] vs $12,287.10 [395.73]; P care unit, symptomatic stenosis, and obesity were associated with increased costs in patients undergoing CAS. These data may aid in identifying opportunities to improve the cost-effectiveness of this procedure. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Restenosis after carotid artery stenting and endarterectomy: a secondary analysis of CREST, a randomised controlled trial.

    Science.gov (United States)

    Lal, Brajesh K; Beach, Kirk W; Roubin, Gary S; Lutsep, Helmi L; Moore, Wesley S; Malas, Mahmoud B; Chiu, David; Gonzales, Nicole R; Burke, J Lee; Rinaldi, Michael; Elmore, James R; Weaver, Fred A; Narins, Craig R; Foster, Malcolm; Hodgson, Kim J; Shepard, Alexander D; Meschia, James F; Bergelin, Robert O; Voeks, Jenifer H; Howard, George; Brott, Thomas G

    2012-09-01

    In the Carotid Revascularization Endarterectomy versus Stenting Trial (CREST), the composite primary endpoint of stroke, myocardial infarction, or death during the periprocedural period or ipsilateral stroke thereafter did not differ between carotid artery stenting and carotid endarterectomy for symptomatic or asymptomatic carotid stenosis. A secondary aim of this randomised trial was to compare the composite endpoint of restenosis or occlusion. Patients with stenosis of the carotid artery who were asymptomatic or had had a transient ischaemic attack, amaurosis fugax, or a minor stroke were eligible for CREST and were enrolled at 117 clinical centres in the USA and Canada between Dec 21, 2000, and July 18, 2008. In this secondary analysis, the main endpoint was a composite of restenosis or occlusion at 2 years. Restenosis and occlusion were assessed by duplex ultrasonography at 1, 6, 12, 24, and 48 months and were defined as a reduction in diameter of the target artery of at least 70%, diagnosed by a peak systolic velocity of at least 3·0 m/s. Studies were done in CREST-certified laboratories and interpreted at the Ultrasound Core Laboratory (University of Washington). The frequency of restenosis was calculated by Kaplan-Meier survival estimates and was compared during a 2-year follow-up period. We used proportional hazards models to assess the association between baseline characteristics and risk of restenosis. Analyses were per protocol. CREST is registered with ClinicalTrials.gov, number NCT00004732. 2191 patients received their assigned treatment within 30 days of randomisation and had eligible ultrasonography (1086 who had carotid artery stenting, 1105 who had carotid endarterectomy). In 2 years, 58 patients who underwent carotid artery stenting (Kaplan-Meier rate 6·0%) and 62 who had carotid endarterectomy (6·3%) had restenosis or occlusion (hazard ratio [HR] 0·90, 95% CI 0·63-1·29; p=0·58). Female sex (1·79, 1·25-2·56), diabetes (2·31, 1·61-3·31

  14. Clinical experience of cerebral protection with balloon occlusion during carotid artery stenting

    International Nuclear Information System (INIS)

    Jaeger, H.J.; Mathias, K.D.; Drescher, R.; Bockisch, G.; Hauth, E.; Demirel, E.; Gissler, H.M.; Witten/Herdecke Univ.

    2001-01-01

    Purpose: To asses the technical feasibility and the results of cerebral protection with the GuardWire Plus Temporary Occlusion and Aspiration System during carotid artery stenting for high-grade stenosis. Patients and Methods: In 20 patients 20 carotid artery stenoses were treated with stent placement under cerebral protection. A contralateral carotid occlusion was an exclusion criteria for the use of the protection device. In all cases only aspiration, but no flushing was used before deflation of the occlusion balloon. In 17 of 20 patients diffusion-weighted (DW-)MRT imaging of the brain was performed before and 24 hours after the procedure. Results: The stent implantation was successfully performed in all patients. In 3 patients neurologic symptoms occurred during the occlusion time. In these 3 patients the symptoms immediately disappeared after deflation of the balloon. In one case there was dilatation of the internal carotid artery at the site of the balloon inflation. In 3 of the 17 DW-MR images new ipsilateral cerebral lesions, in one case a new contralateral lesion occurred after the procedure. Conclusions: The cerebral protection procedure is technically feasible. The occlusion of the internal carotid artery was not tolerated by all patients. The DW-MR imaging demonstrated cerebral lesions indicating the occurrence of cerebral microemboli during the procedure. Further investigations are necessary to determine if the use of the cerebral protection device will improve the results of the carotid artery stenting for high-grade stenoses. (orig.) [de

  15. Extracranial Carotid Artery Stenting in Surgically High-Risk Patients Using the Carotid Wallstent Endoprosthesis:Midterm Clinical and Ultrasound Follow-Up Results

    International Nuclear Information System (INIS)

    Maleux, Geert; Bernaerts, Pauwel; Thijs, Vincent; Daenens, Kim; Vaninbroukx, Johan; Fourneau, Inge; Nevelsteen, Andre

    2003-01-01

    The purpose of this study was to evaluate the feasibility, safety and midterm outcome of elective implantation of the Carotid Wallstent (registered) in patients considered to be at high surgical risk. In a prospective study, 54 carotid artery stenoses in 51 patients were stented over a 24-month period. Three patients underwent bilateral carotid artery stenting. Institutional inclusion criteria for invasive treatment of carotid occlusive disease (carotid endarterectomy or carotid artery stenting) are patients presenting with a 70% or more symptomatic stenosis and those with an 80% or more asymptomatic stenosis having a life-expectancy of more than 1 year. All patients treated by carotid artery stenting were considered at high risk for carotid endarterectomy because of a hostile neck (17 patients-31.5%) or because of severe comorbidities (37 patients-68.5%). No cerebral protection device was used. Of the 54 lesions, 33 (61.1%) were symptomatic and 21 (38.8%) were asymptomatic. Follow-up was performed by physical examination and by duplex ultrasonography at 1 month, 6 months, 1 year and 2 years after the procedure. All 54 lesions could be stented successfully without periprocedural stroke. Advert events during follow-up (mean 13.9 ± 5.7 months) were non-stroke-related death in 6 patients (11.1%), minor stroke in 4 stented hemispheres(7.4%), transient ipsilateral facial pain in 1 patient (1.8%),infection of the stented surgical patch in 1 patient (1.8%) and asymptomatic in stent restenosis in 4 patients (7.4%). The percutaneous implantation of the Carotid Wallstent (registered) , even without cerebral protection device, appears to be a safe procedure with acceptable clinical and ultrasonographic follow-up results in patients at high surgical risk. But some late adverse events such as ipsilateral recurrence of non-disabling (minor) stroke or in stent restenosis still remain real challenging problems

  16. Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

    Energy Technology Data Exchange (ETDEWEB)

    Ruffino, Maria Antonella, E-mail: mruffino@cittadellasalute.to.it [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy); Faletti, Riccardo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Bergamasco, Laura [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Department of Surgical Sciences (Italy); Fonio, Paolo [University of Torino, Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Radiology Unit, Department of Surgical Sciences (Italy); Righi, Dorico [Azienda Ospedaliera Universitaria- Città della Salute e della Scienza di Torino, San Giovanni Battista Hospital, Vascular Radiology Unit, Department of Diagnostic Imaging and Radiotherapy (Italy)

    2016-11-15

    AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm{sup 3} (interquartile range 0.065–0.146 cm{sup 3}). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.

  17. Incidence of New Ischaemic Brain Lesions After Carotid Artery Stenting with the Micromesh Roadsaver Carotid Artery Stent: A Prospective Single-Centre Study

    International Nuclear Information System (INIS)

    Ruffino, Maria Antonella; Faletti, Riccardo; Bergamasco, Laura; Fonio, Paolo; Righi, Dorico

    2016-01-01

    AimsSeveral randomized trials of patients with carotid stenosis show increased adverse neurological events with stenting versus endarterectomy in the 30-day post-procedure. This study examines the incidence of new ischaemic lesions in patients treated in our centre using the new Roadsaver stent.Methods and resultsBetween September 2015 and January 2016, 23 consecutive patients (age 74.3 ± 7.3 years, 17.4 % female) underwent carotid artery stenting with the Roadsaver stent, a nitinol double-layer micromesh device. A distal protection device was used in all cases. Diffusion-weighted magnetic resonance imaging was performed 24 h before, and 24 h and 30 days after the procedure. The 24-h post-procedure imaging showed 15 new ipsilateral ischaemic lesions in 7 (30.4 %) patients: median volume 0.076 cm"3 (interquartile range 0.065–0.146 cm"3). All lesions were asymptomatic. The 30-day imaging showed complete resolution of all lesions and no new ischaemic lesions. Follow-up clinical and ultrasound examinations at 30 days and 6 months recorded no adverse cardiac or cerebrovascular events.ConclusionsProtected stenting with micromesh Roadsaver stent showed good safety and efficacy in the treatment of carotid stenosis, with a low incidence of delayed embolic events and new ipsilateral ischaemic brain lesions. These preliminary results are encouraging, but need to be confirmed with larger populations.

  18. Carotid Artery Stenting Successfully Prevents Progressive Stroke Due to Mobile Plaque

    Directory of Open Access Journals (Sweden)

    Masahiro Oomura

    2015-05-01

    Full Text Available We report a case of progressive ischemic stroke due to a mobile plaque, in which carotid artery stenting successfully prevented further infarctions. A 78-year-old man developed acute multiple infarcts in the right hemisphere, and a duplex ultrasound showed a mobile plaque involving the bifurcation of the left common carotid artery. Maximal medical therapy failed to prevent further infarcts, and the number of infarcts increased with his neurological deterioration. Our present case suggests that the deployment of a closed-cell stent is effective to prevent the progression of the ischemic stroke due to the mobile plaque.

  19. Enterprise stent in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion.

    Science.gov (United States)

    Wang, Xiaofei; Wang, Zhigang; Ji, Yong; Ding, Xuan; Zang, Yizheng; Wang, Chengwei

    2017-11-01

    To investigate the safety and effectiveness of recanalization in non-acute occlusion of intracranial internal carotid arteries using the flexible Enterprise self-expanding stent. From June 2014 to June 2016, 12 consecutive patients with non-acute occlusion of intracranial internal carotid arteries received endovascular recanalization with Enterprise stenting. All patients received medication for anti-platelet aggregation therapy before and after the operation. The perioperative complications and recanalization efficacy were evaluated with the modified Rankin scoring system and digital subtraction angiography (DSA) follow-up, respectively. Endovascular recanalization was successfully performed in 10 out of 12 patients with Enterprise stenting. Stent implantation following balloon dilatation failed in one patient because the lumen diameter was too small. Another recanalization failed because the guide wire could not pass through the occlusion. No perioperative mortality was observed. One case of acute thrombosis and one case of intraoperative carotid spasm occurred, but these were resolved with thrombolytic therapy by microcatheter exposure treatment and antispasmodic medications, respectively. DSA follow-up in seven patients revealed no re-occlusion. One stroke event occurred in the 10 patients who completed the follow-up. A meaningful improvement in the modified Rankin score during follow-up was suggested by Wilcoxon signed-rank test results. The Enterprise stent was shown to be safe and efficient in recanalizing non-acute atherosclerotic intracranial internal carotid artery occlusion. However, the long-term outcomes need to be further investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Fatal Intraventricular Hemorrhage After the Extracranial Carotid Artery Angioplasty and Stent Placement

    International Nuclear Information System (INIS)

    Krajickova, Dagmar; Krajina, Antonin; Nova, Marketa; Raupach, Jan

    2005-01-01

    We report on a 72-year-old female with an unusual intracranial bleeding complication after an extracranial carotid artery stenting procedure performed for a tight left ICA stenosis associated with contralateral carotid occlusion. Two hours after the procedure, the initial signs of intracranial bleeding appeared that led to the patient's demise 5 days later. A brain CT showed and autopsy proved massive intraventricular bleeding. To our knowledge, our case is only the second report of isolated reperfusion intraventricular hemorrhage post-CAS

  1. Stent implantation for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation

    International Nuclear Information System (INIS)

    Xing Ming; Yang Pengfei; Huang Qinghai; Zhao Wenyuan; Hong Bo; Xu Yi; Liu Jianmin

    2012-01-01

    Objective: To preliminarily evaluate the feasibility, safety and efficacy of stent placement for the treatment of wide-necked aneurysms located at internal carotid artery bifurcation. Methods: Eleven patients with wide-necked aneurysms located at internal carotid artery bifurcation, who were encountered during the period from Jan. 2004 to Dec. 2010 in hospital, were collected. A total of 16 intracranial aneurysms were detected, of which 11 were wide-necked and were located at internal carotid artery bifurcation. The diameters of the aneurysms ranged from 2.5 mm to 18 mm. Individual stent type and stenting technique was employed for each patient. Follow-up at 1, 3, 6 and 12 months after the procedure was conducted. Results: A total of 11 different stents were successfully deployed in the eleven patients. The stents included balloon expandable stent (n=1) and self-expanding stent (n=10). According to Raymond grading for the immediate occlusion of the aneurysm, grade Ⅰ (complete obliteration) was obtained in 4, grade Ⅱ (residual neck) in 2 and grade Ⅲ (residual aneurysm) in 5 cases. No procedure-related complications occurred. At the time of discharge, the modified Rankin score was 0-1 in the eleven patients. During the follow-up period lasting for 1-108 months, all the patients were in stable condition and no newly-developed neurological dysfunction or bleeding observed. Follow-up examination with angiography (1-48 months) showed that the aneurysms were cured (no visualization) in 4 cases, improved in 2 cases and in stable condition in one case. Conclusion: For the treatment of wide-necked aneurysms located at internal carotid artery bifurcation, stent implantation is clinically feasible, safe and effective. Further studies are required to evaluate its long-term efficacy. (authors)

  2. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  3. Zotarolimus-eluting stent for the treatment of recurrent, severe carotid artery in-stent stenosis in the TARGET-CAS population.

    Science.gov (United States)

    Tekieli, Lukasz; Pieniazek, Piotr; Musialek, Piotr; Kablak-Ziembicka, Anna; Przewlocki, Tadeusz; Trystula, Mariusz; Moczulski, Zbigniew; Dzierwa, Karolina; Paluszek, Piotr; Podolec, Piotr

    2012-06-01

    To evaluate the safety and efficacy of a balloon-mounted drug-eluting stent (DES) for recurrent carotid in-stent stenosis (ISS). As part of our targeted carotid artery stenting (TARGET-CAS) protocol, neurological and ultrasound evaluations have been performed at 3, 6, and 12 months and then annually since 2001 in all carotid stent patients. For angiographically-confirmed >70% ISS, balloon angioplasty was performed as a first-line treatment. Recurrent ISS was treated with a 4.0-mm zotarolimus-eluting coronary stent (ZES) that was postdilated according to intravascular ultrasound imaging. Among the 1350 neuroprotected CAS procedures performed between January 2001 and March 2011, there were 7 (0.52%) patients (5 men; ages 51-72 years), all neurologically asymptomatic, with >70% recurrent ISS that occurred at 5 to 11 months after the initial balloon angioplasty treatment for ISS. ZES implantation under distal embolic protection was technically successful and uncomplicated. Angiographic stenosis was reduced from 84.6%±7.5% to 10.7%±3.6% (p<0.01). In 5 patients with ZES implanted fully within the self-expanding carotid stent, duplex ultrasound follow-up (mean 17 months, range 6-36) revealed no evidence of restenosis or stent fracture/deformation. In the 2 other patients, the ZES had been implanted for distal edge ISS such that the ZES protruded beyond the original carotid stent. This protruding segment of the ZES demonstrated deformation/kinking in both; in one, this led to symptomatic stent occlusion. The use of coronary ZES in the treatment of recurrent carotid ISS is feasible and appears effective provided the ZES is placed entirely within the original stent. Placement of a coronary ZES outside the carotid stent scaffold should be avoided.

  4. Heparin surface stent-graft for the treatment of a carotid pseudoaneurysm.

    Science.gov (United States)

    Tsolaki, Elpiniki; Elpiniki, Tsolaki; Salviato, Elisabetta; Rocca, Tiberio; Braccini, Lucia; Galeotti, Roberto; Mascoli, Francesco

    2010-10-01

    Carotid pseudoaneurysms are a rare consequence of carotid surgery, trauma, and infection. Historically, carotid aneurysms and pseudoaneurysms were treated surgically. However, endovascular techniques have recently become a valid alternative for the treatment of carotid pseudoaneurysms. The case of a 57-year-old male patient with a pseudoaneurysm of the right internal carotid artery is described. The patient came to our unit with a painless and pulsatile mass in the neck, which was growing slowly. Five years earlier, he had undergone surgery on a saccular aneurysm located on the distal extracranial segment of the right internal carotid artery. The pseudoaneurysm was successfully treated with a heparin surface Viabahn stent-graft system (Gore AL, Flagstaff, AZ). Heparin surface stent-grafts can be used for the treatment of carotid lesions and may offer protection against intimal hyperplasia and thrombosis. Further studies are needed to evaluate the long-term results. Copyright © 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  5. Carotid Web (Intimal Fibromuscular Dysplasia) Has High Stroke Recurrence Risk and Is Amenable to Stenting.

    Science.gov (United States)

    Haussen, Diogo C; Grossberg, Jonathan A; Bouslama, Mehdi; Pradilla, Gustavo; Belagaje, Samir; Bianchi, Nicolas; Allen, Jason W; Frankel, Michael; Nogueira, Raul G

    2017-11-01

    Carotid webs have been increasingly recognized as a cause of recurrent stroke, but evidence remains scarce. We aim to report the clinical outcomes and first series of carotid stenting in a cohort of patients with strokes from symptomatic carotid webs. Prospective and consecutive data of patients web was defined by a shelf-like/linear filling defect in the posterior internal carotid artery bulb by computed tomographic angiography. Twenty-four patients were identified (91.6% strokes/8.4% transient ischemic attacks [TIAs]). Median age was 46 (41-59) years, 61% were female, and 75% were black. Median National Institutes of Health Stroke Scale score was 10.5 (3.0-16.0) and ASPECTS (Alberta Stroke Program Early CT Score) was 8 (7-8). There were no parenchymal hemorrhages, and 96% of patients were independent at 3 months. All webs caused webs (58%), median ipsilateral web length was larger than contralateral (3.1 [3.0-4.5] mm versus 2.6 [1.85-2.9] mm; P =0.01), respectively. Twenty-nine percent of patients had thrombus superimposed on the symptomatic carotid web. A recurrent stroke/TIA involving the territory of the previously symptomatic web occurred in 7 (32%; 6 strokes/1 TIA) patients: 3 1 year of follow-up. Two recurrences occurred on dual antiplatelet therapy, 3 on antiplatelet monotherapy, 1 within 24 hours of thrombolysis, and 1 off antithrombotics. Median follow-up was 12.2 (8.0-18.0) months. Sixteen (66%) patients were stented at a median 12.2 (7.0-18.7) days after stroke with no periprocedural complications. No recurrent strokes/TIAs occurred in stented individuals (median follow-up of 4 [2.4-12.0] months). Carotid web is associated with high recurrent stroke/TIA risk, despite antithrombotic use, and is amenable to carotid stenting. © 2017 American Heart Association, Inc.

  6. Bilateral spontaneous internal carotid artery dissection managed with endovascular stenting – A case report

    Directory of Open Access Journals (Sweden)

    Manoj Kumar Agarwala

    2016-09-01

    We describe a patient with ischemic stroke from spontaneous bilateral ICAD with completely occluded left ICA. Having failed medical therapy with antiplatelets and anticoagulants due to extensive loss of carotid vascular supply, he was managed successfully with endovascular stenting with good neurological recovery.

  7. FiberNet--a new embolic protection device for carotid artery stenting.

    Science.gov (United States)

    Bauer, C; Franke, J; Bertog, S C; Woerner, V; Ghasemzadeh-Asl, S; Sievert, H

    2014-05-01

    Though distal filter protection during carotid stenting reduces the risk of cerebrovascular events, periprocedural stroke remains a risk despite their broad usage. This observation may be related to the pore size of common filters. The FiberNet distal filter system is unique by its very small pore size (40 µm) as well as its low profile and flexibility. Little data is available regarding the clinical performance and safety of this device. The aim was the evaluation of the safety of the FiberNet embolic protection system during carotid artery stenting. All consecutive patients treated with carotid stenting at our institution using the FiberNet device were systematically followed. Primary endpoint was the rate of all death and stroke within 30 days of the procedure. Carotid artery stenting using the FiberNet embolic protection system was performed in 54 patients. The procedure was technical successful in all patients. Three patients (5.5%) had a TIA. Amauosis fugax occurred in two patients (3.7%). One patient (1.9%) had a minor stroke with hemiparesis of the left arm and face which resolved completely within 48 hr after the procedure. No patient died or suffered a major stroke. The safety and feasibility of the FiberNet distal protection system appears to be at least equivalent to that reported in studies using conventional distal filter protection. Copyright © 2013 Wiley Periodicals, Inc.

  8. Dose-Dependent Effect of Statin Pretreatment on Preventing the Periprocedural Complications of Carotid Artery Stenting.

    Science.gov (United States)

    Hong, Jeong-Ho; Sohn, Sung-Il; Kwak, Jaehyuk; Yoo, Joonsang; Chang, Hyuk Won; Kwon, O-Ki; Jung, Cheolkyu; Chung, Inyoung; Bae, Hee-Joon; Lee, Ji Sung; Han, Moon-Ku

    2017-07-01

    We investigated whether statin pretreatment can dose dependently reduce periprocedural complications in patients undergoing carotid artery stenting because of symptomatic carotid artery stenosis. We enrolled a consecutive series of 397 symptomatic carotid artery stenosis (≥50% stenosis on conventional angiography) treated with carotid artery stenting at 2 tertiary university hospitals over a decade. Definition of periprocedural complications included any stroke, myocardial infarction, and death within 1 month after or during the procedure. Statin pretreatment was divided into 3 categories according to the atorvastatin equivalent dose: none (n=158; 39.8%), standard dose (statin use were 12.0%, 4.5%, and 1.2%. After adjustment, a change in the atorvastatin dose category was associated with reduction in the odds of periprocedural complications for each change in dose category (standard-dose statin: odds ratio, 0.24; 95% confidence interval, 0.07-0.81; high-dose statin: odds ratio, 0.11; 95% confidence interval, 0.01-0.96; P for trend=0.01). Administration of antiplatelet drugs was also an independent factor in periprocedural complications (OR, 0.18; 95% CI, 0.05-0.69). This study shows that statin pretreatment may reduce the incidence of periprocedural complications dose dependently in patients with symptomatic carotid artery stenting. © 2017 American Heart Association, Inc.

  9. Association between age and risk of stroke or death from carotid endarterectomy and carotid stenting : A meta-analysis of pooled patient data from four randomised trials

    NARCIS (Netherlands)

    Howard, George; Roubin, Gary S.; Jansen, Olav; Hendrikse, Jeroen; Halliday, Alison; Fraedrich, Gustav; Eckstein, Hans Henning; Calvet, David; Bulbulia, Richard; Bonati, Leo H.; Becquemin, Jean Pierre; Algra, Ale; Brown, Martin M.; Ringleb, Peter A.; Brott, Thomas G.; Mas, Jean Louis

    2016-01-01

    Background: Age was reported to be an effect-modifier in four randomised controlled trials comparing carotid artery stenting (CAS) and carotid endarterectomy (CEA), with better CEA outcomes than CAS outcomes noted in the more elderly patients. We aimed to describe the association of age with

  10. Treatment of internal carotid artery dissections with endovascular stent placement: report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Deok Hee; Hur, Seung Ho; Kim, Hyeon Gak; Jung, Seung Mun; Ryu, Dae Sik; Park, Man Soo [Kangnung Hospital, Kangnung (Korea, Republic of)

    2000-03-01

    Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  11. Carotid Artery Stenting and Endarterectomy: a clinical evaluation

    NARCIS (Netherlands)

    J.M. Hendriks (Joke)

    2011-01-01

    textabstractStroke is a major cause of mortality and morbidity in the western world. Atherosclerotic disease of the carotid arteries is in approximately 25% of the cases responsible for the cerebral infarction.1 Since NASCET and ECST, carotid endarterectomy (CEA) is considered the standard treatment

  12. Transcatheter Closure of a Chronic Iatrogenic Arteriovenous Fistula Between the Carotid Artery and the Brachiocephalic Vein with an Amplatzer Duct Occluder in Combination with a Carotid Stent

    International Nuclear Information System (INIS)

    Stasek, Josef; Lojik, Miroslav; Bis, Josef; Horak, David; Dusek, Jaroslav; Brtko, Miroslav; Polansky, Pavel; Babu, Anush; Vojacek, Jan

    2009-01-01

    We report an original method of transcatheter closure of an arteriovenous fistula using the combination of an Amplatzer PDA occluder and a carotid stent. The fistula was between the left carotid artery and the brachiocephalic vein. The patient had significant left-to-right shunt and was highly symptomatic. Due to the large orifice and pseudoaneurysmatic enlargement of the fistula, we had to use a large Amplatzer PDA occluder and the protruding part of the PDA device disk had to be covered with a carotid stent. The fistula was completely closed. The patient stopped having symptoms and, 2 years after the procedure, the effect persists.

  13. A Prospective, Multicenter Study of a Novel Mesh-Covered Carotid Stent: The CGuard CARENET Trial (Carotid Embolic Protection Using MicroNet).

    Science.gov (United States)

    Schofer, Joachim; Musiałek, Piotr; Bijuklic, Klaudija; Kolvenbach, Ralf; Trystula, Mariusz; Siudak, Zbigniew; Sievert, Horst

    2015-08-17

    This study sought to evaluate the feasibility of the CGuard Carotid Embolic Protective Stent system-a novel thin strut nitinol stent combined with a polyethylene terephthalate mesh covering designed to prevent embolic events from the target lesion in the treatment of carotid artery lesions in consecutive patients suitable for carotid artery stenting. The risk of cerebral embolization persists throughout the carotid artery stenting procedure and remains during the stent healing period. A total of 30 consecutive patients (age 71.6 ± 7.6 years, 63% male) meeting the conventional carotid artery stenting inclusion criteria were enrolled in 4 centers in Germany and Poland. The primary combined endpoint was the procedure success of the CGuard system and the number and volume of new lesions on the ipsilateral side assessed by diffusion-weighted magnetic resonance imaging at 48 h post-procedure and at 30 days. The secondary endpoint was 30-day major adverse cardiac or cerebrovascular events (death, stroke, or myocardial infarction). Protection devices were used in all procedures. Procedure success was 100%, with 0% procedural complications. The 30-day major adverse cardiac or cerebrovascular events rate was 0%. New ipsilateral ischemic lesions at 48 h occurred in 37.0% of patients and the average lesion volume was 0.039 ± 0.08 cm(3). The 30-day diffusion-weighted magnetic resonance imaging showed complete resolution of all but 1 periprocedural lesion and only 1 new minor (0.116 cm(3)) lesion in relation to the 48-h scan. The use of the CGuard system in patients undergoing carotid artery stenting is feasible. In addition, the benefit of using CGuard may extend throughout the stent healing period. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Diffusion-weighted magnetic resonance imaging in carotid angioplasty and stenting with balloon embolic protection devices

    International Nuclear Information System (INIS)

    Asakura, Fumio; Kawaguchi, Kenji; Sakaida, Hiroshi; Toma, Naoki; Matsushima, Satoshi; Kuraishi, Keita; Tanemura, Hiroshi; Miura, Yoichi; Taki, Waro; Maeda, Masayuki

    2006-01-01

    We compared the results of two procedures to protect against distal embolism caused by embolic debris from carotid angioplasty with stent deployment (CAS) using diffusion-weighted magnetic resonance imaging (MRI). The study group comprised 39 men and 3 women (42 and 3 CAS procedures, respectively) with severe carotid stenosis (average age 70.0±6.6 years). During 20 CAS procedures the internal carotid artery was protected with a single balloon. A PercuSurge GuardWire was used for temporary occlusion. During 25 CAS procedures the internal and external carotid arteries were simultaneously temporarily occluded with a PercuSurge GuardWire and a Sentry balloon catheter, respectively. Diffusion-weighted MRI was performed 1 to 3 days after CAS. Data from 26 patients undergoing conventional angiography for diagnosis of cerebral ischemic disease, cerebral aneurysm or brain tumors were included as controls. Diffusion-weighted MRI after conventional diagnostic angiography showed ischemic spots in 3 of the 26 controls (11.5%). Ischemic spots were observed during 11 of 20 CAS procedures with the internal carotid artery protected with a single balloon (55.0%), and were observed during 9 of 25 CAS procedures with both the internal and external carotid arteries protected (36.0%). This difference was significant (P=0.0068). Ischemic lesions appeared not only ipsilateral to the carotid stenosis but also in the contralateral carotid artery (31.9%) and vertebrobasilar territory (25.3%). Better protection was obtained with simultaneous double occlusion of both the internal and external carotid artery than with single protection of the internal carotid artery during CAS. (orig.)

  15. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    International Nuclear Information System (INIS)

    Mourand, Isabelle; Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain; Thouvenot, Eric

    2010-01-01

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS ≤1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  16. Endovascular stent-assisted thrombolysis in acute occlusive carotid artery dissection

    Energy Technology Data Exchange (ETDEWEB)

    Mourand, Isabelle [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France); Hopital Gui de Chauliac, Department of Neurology, Service de Neurologie, Montpellier, Cedex 5 (France); Brunel, Herve; Vendrell, Jean-Francois; Bonafe, Alain [Hopital Gui de Chauliac, Department of Neuroradiology, CHU Montpellier, Montpellier, Cedex 5 (France); Thouvenot, Eric [Hopital Gui de Chauliac, Department of Neurology, CHU Montpellier, Montpellier, Cedex 5 (France)

    2010-02-15

    Internal carotid artery dissection with tandem internal carotid and middle cerebral artery occlusion may be responsible for large cerebral infarction that carries a general poor prognosis. Recanalization of internal carotid artery (ICA) dissection by stent-assisted thrombolysis has been recently proposed. We report two cases of acute symptomatic ICA dissection with tandem occlusion successfully treated with emergent endovascular stent-assisted thrombolysis using new self-expandable intracranial stents. A 37-year-old woman and a 59-year-old man were admitted in our hospital after acute severe symptoms of right-hemispheric stroke with National Institutes of Health Stroke Scale (NIHSS) scores of 15 and 18, respectively. In both cases, magnetic resonance angiography showed tandem occlusion and angiography confirmed tandem occlusion with ICA dissection. An extensive mismatch region was diagnosed by Perfusion-diffusion MRI of the brain within 3 h after symptoms onset. Treatment was initiated 4 h after symptom onset by implantation of self-expandable intracranial stents into the dissected ICA and administration of intra-arterial recombinant tissue plasminogen activator. Recanalization of the ICA and middle cerebral artery (MCA) was accomplished within 6 h after symptoms onset. In both cases, no periprocedural complication was observed and follow-up CT scan showed only a mild brain infarct in the MCA territory. After, respectively, 12 and 10 months follow-up, patients had a favorable outcome with NIHSS 0 and mRS {<=}1. Endovascular stent-assisted thrombolysis appears to be a promising treatment in tandem occlusion due to ICA dissection. Our work underline the potential use of self-expandable intracranial stents in symptomatic acute ICA dissection. (orig.)

  17. Clinical Results and Mechanical Properties of the Carotid CGUARD Double-Layered Embolic Prevention Stent.

    Science.gov (United States)

    Wissgott, Christian; Schmidt, Wolfram; Brandt-Wunderlich, Christoph; Behrens, Peter; Andresen, Reimer

    2017-02-01

    To report early clinical outcomes with a novel double-layer stent for the internal carotid artery (ICA) and the in vitro investigation of the stent's mechanical properties. A prospective single-center study enrolled 30 consecutive patients (mean age 73.1±6.3 years; 21 men) with symptomatic (n=25) or high-grade (n=5) ICA stenosis treated with the new double-layer carotid CGUARD Embolic Prevention System (EPS) stent, which has an inner open-cell nitinol design with an outer closed-cell polyethylene terephthalate layer. The average stenosis of the treated arteries was 84.1%±7.9% with a mean lesion length of 16.6±2.1 mm. In the laboratory, 8×40-mm stents where tested in vitro with respect to their radial force during expansion, the bending stiffness of the stent system and the expanded stent, as well as the collapse pressure in a thin and flexible sheath. The wall adaptation was assessed using fluoroscopy after stent release in step and curved vessel models. The stent was successfully implanted in all patients. No peri- or postprocedural complications occurred; no minor or major stroke was observed in the 6-month follow-up. The bending stiffness of the expanded stent was 63.1 N·mm 2 and (not unexpectedly) was clearly lower than that of the stent system (601.5 N·mm 2 ). The normalized radial force during expansion of the stent to 7.0 mm, consistent with in vivo sizing, was relatively high (0.056 N/mm), which correlates well with the collapse pressure of 0.17 bars. Vessel wall adaptation was harmonic and caused no straightening of the vessel after clinical application. Because of its structure, the novel CGUARD EPS stent is characterized by a high flexibility combined with a high radial force and very good plaque coverage. These first clinical results demonstrate a very safe implantation behavior without any stroke up to 6 months after the procedure.

  18. Installation of carotid stent in a group of patient of high surgical risk for carotid endarterectomy - Preliminary experience

    International Nuclear Information System (INIS)

    Gomez Hoyos, Juan Fernando; Celis Mejia, Jorge Ignacio; Yepes Sanchez, Carlos Jaime; Duque Botero, Julieta

    1998-01-01

    Carotid endarterectomy success in symptomatic or asymptomatic patients has been demonstrated in NASCET and ACAS studies. Although, some patients with carotid stenosis have frequently other pathologies which increase risk in endarterectomy or other surgeries like coronary bypass and aortic-iliac reconstruction. Other patients have lesions such as post surgical restenosis, fibromuscular dysplasia, radiation stenosis or tumoral disease, or stenotic lesions above jaw angle. The main objectives of this work are: to demonstrate, upon the results, that multidisciplinary management of 1 patient with symptomatic or not carotid critical stenosis. Let to select, with strict clinical criteria, those doing well with endovascular therapy. To evaluate implantation technique, peryoperatory morbidity and mortality and permeability time with implanted dispositive. In this study, the preliminary experience of the neurovascular group at the Clinica Cardiovascular Santa Maria in Medellin is presented, during an 18 months period of multidisciplinary management in 15 patients, 7 men and 8 women with critical carotid stenosis. 18 procedures were performed and 21 stents were implanted. The mean age was 66 years. All patients had 70% or greater stenotic lesions, and 93.3% were symptomatic. Twelve (80%) had contraindications to perform surgery. one asymptomatic patient (6.6%) was referred with procedure indications and two (13.3%) requested the stent implantation as their own election. the patient with fibromuscular dysplasia was treated with Wallstent (number 4) and the remaining patients were treated with Palmaz stent. technical success was 100%, 3 patients had pacemaker rhythm, one patient (6.6%) presented extra-pyramidal syndrome which responded to medical treatment in 24 hours. one patient developed right side hemiparesis with total recovery in 4 hours. One patient with a critical left carotid artery stenosis presented right side hemiparesis (3/5) and aphasia, nine months later paresis

  19. Stenting versus endarterectomy for restenosis following prior ipsilateral carotid endarterectomy : An individual patient data meta-analysis

    NARCIS (Netherlands)

    Fokkema, Margriet; Vrijenhoek, Joyce E P; Ruijter, Hester M Den; Groenwold, Rolf H H; Schermerhorn, Marc L.; Bots, Michiel L.; Pasterkamp, Gerard; Moll, Frans L.; De Borst, Gert Jan

    2015-01-01

    Objective: To study perioperative results and restenosis during follow-up of carotid artery stenting (CAS) versus carotid endarterectomy (CEA) for restenosis after prior ipsilateral CEA in an individual patient data (IPD) metaanalysis. Background: The optimal treatment strategy for patients with

  20. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jang Hyun; Kim, Byung Moon [Dept. of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  1. Stenting for symptomatic vertebral artery stenosis associated with bilateral carotid rate mirabile: The long-term clinical and angiographic outcome

    International Nuclear Information System (INIS)

    Baek, Jang Hyun; Kim, Byung Moon

    2015-01-01

    Symptomatic vertebral artery (VA) stenosis associated with bilateral carotid rate mirabile (CRM) has not been reported. We report the long-term clinical and angiographic outcome after stenting for symptomatic VA stenosis in the patient with bilateral CRM. This report is the first case that symptomatic VA stenosis associated with bilateral CRM was treated with stenting.

  2. Distal Marginal Stenosis: A Contributing Factor in Delayed Carotid Occlusion of a Patient With Carotid Blowout Syndrome Treated With Stent Grafts

    Directory of Open Access Journals (Sweden)

    Feng-Chi Chang

    2010-05-01

    Full Text Available Distal marginal stenosis is rarely reported to be a factor associated with poor long-term patency of patients of head and neck cancers with carotid blowout syndrome treated with stent grafts. We report a case of laryngeal cancer with rupture of the right common carotid artery. A self-expandable stent graft was deployed, but bleeding recurred. Another stent graft was deployed for the pseudoaneurysm located distal to the first stent graft. Rebleeding occurred because of pseudoaneurysm formation from reconstituted branches of the right superior thyroid artery. We performed direct percutaneous puncture of the proximal superior thyroid artery for successful embolization. Distal marginal stenosis and asymptomatic thrombosis of the carotid artery were noted at 3.5- and 5-month follow-ups, respectively. We suggest aggressive early follow-up and reintervention for distal marginal stenosis by combined antibiotic therapy and angioplasty and stenting to improve the long-term patency of stent-graft deployment for management of carotid blowout syndrome.

  3. The Impact of Carotid Artery Stenting on Cerebral Perfusion, Functional Connectivity, and Cognition in Severe Asymptomatic Carotid Stenosis Patients

    Directory of Open Access Journals (Sweden)

    Tao Wang

    2017-08-01

    Full Text Available Background and purposeAsymptomatic carotid artery stenosis can lead to not only stroke but also cognition impairment. Although it has been proven that carotid artery stenting (CAS can reduce the risk of future strokes, the effect of CAS on cognition is conflicting. In recent years, pulsed arterial spin labeling (pASL MRI and resting-state functional MRI (R-fMRI have been employed in cognitive impairment studies. For the present study, cognition is evaluated in severe asymptomatic carotid artery stenosis patients undergoing CAS, and the mechanisms underlying the cognitive change are explored by pASL MRI and R-fMRI.Materials and methodsWe prospectively enrolled 24 asymptomatic, severe (≥70%, unilateral internal carotid artery stenosis patients, who were expecting the intervention of CAS. Cognition assessment (including the Montreal Cognitive Assessment Beijing Version, the Minimum Mental State Examination, the Digit Symbol Test, the Rey Auditory Verbal Learning Test, and the Verbal Memory Test and an integrated MRI program (pASL MRI, and R-fMRI were administered 7 days before and 3 months after CAS.Results16 subjects completed the follow-up study. After stenting, significant improvement in the scores of the MMSE, the Verbal Memory test, and the delayed recall was found. No significant difference was found in the scores of the Montreal Cognitive Assessment Beijing Version, the Digit Symbol Test, and the immediate recall. After CAS treatment, asymptomatic carotid artery stenosis patients showed increased perfusion in the left frontal gyrus, increased amplitude of low-frequency fluctuation (ALFF in the right precentral gyrus, and increased connectivity to the posterior cingulate cortex (PCC in the right supra frontal gyrus. However, no significant correlations were found between these imaging changes and cognition assessments.ConclusionSuccessful CAS can partly improve cognition in asymptomatic carotid artery stenosis patients. The cognition

  4. Influence of stent design and use of protection devices on outcome of carotid artery stenting: a pooled analysis of individual patient data.

    Science.gov (United States)

    Wodarg, Fritz; Turner, Elisabeth L; Dobson, Joanna; Ringleb, Peter A; Mali, Willem P; Fraedrich, Gustav; Chatellier, Gilles; Bequemin, Jean-Pierre; Brown, Martin M; Algra, Ale; Mas, Jean-Louis; Jansen, Olav; Bonati, Leo H

    2018-04-19

    Carotid artery stenting is an alternative to endarterectomy for the treatment of symptomatic carotid stenosis but was associated with a higher risk of procedural stroke or death in randomized controlled trials (RCTs). Technical aspects of treatment may partly explain these results. The purpose of this analysis was to investigate the influence of technical aspects such as stent design or the use of protection devices, as well as clinical variables, on procedural risk. We pooled data of 1557 individual patients receiving stent treatment in three large RCTs comparing stenting versus endarterectomy for symptomatic carotid stenosis. The primary outcome event was any procedural stroke or death occurring within 30 days after stenting. Procedural stroke or death occurred significantly more often with the use of open-cell stents (61/595 patients, 10.3%) than with closed-cell stents (58/962 patients, 6.0%; RR 1.76; 95% CI 1.23 to 2.52; P=0.002). Procedural stroke or death occurred in 76/950 patients (8.0%) treated with protection devices (predominantly distal filters) and in 43/607 (7.1%) treated without protection devices (RR 1.10; 95% CI 0.71 to 1.70; P=0.67). Clinical variables predicting the primary outcome event were age, severity of the qualifying event, history of prior stroke, and level of disability at baseline. The effect of stent design remained similar after adjustment for these variables. In symptomatic carotid stenosis, the use of stents with a closed-cell design is independently associated with a lower risk of procedural stroke or death compared with open-cell stents. Filter-type protection devices do not appear to reduce procedural risk. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Cerebral foreign body reaction after carotid aneurysm stenting

    DEFF Research Database (Denmark)

    Lorentzen, Anastasia Orlova; Nome, Terje; Bakke, Søren Jacob

    2016-01-01

    Flow diverter stents are new important tools in the treatment of large, giant, or wide-necked aneurysms. Their delivery and positioning may be difficult due to vessel tortuosity. Common adverse events include intracranial hemorrhage and ischemic stroke, which usually occurs within the same day...

  6. Outcomes of emergent carotid artery stenting within 6 hours of symptom onset in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Jeong, Won Gi; Yoon, Woong; Yim, Nam Yeol; Jung, Min Young; Jung, Se Hee; Kang, Heoung Keun

    2013-01-01

    To investigate clinical outcomes following the emergent carotid artery stenting for treatment of acute ischemic stroke. Twenty-eight consecutive patients with acute stroke due to atherosclerotic steno-occlusive diseases of extracranial internal carotid artery underwent emergent carotid artery stenting. Of these, 23 patients had tandem intracranial arterial occlusions. Extracranial carotid stenting was successful in all patients. From the 13 patients who underwent intracranial recanalization procedures, successful recanalization occurred in 84.6% (11/13). 57% of patients (16/28) had a good clinical outcome (modified Rankin Scale 0-2) after 3 months. Patients with successful intracranial/extracranial recanalization had a significantly higher rate of good outcome than those without recanalization after 3 months (75% vs. 33%, p = 0.027). Patients without intracranial tandem occlusions had a more favorable clinical outcome than those with intracranial tandem occlusions (100% vs. 48%, p = 0.033). Symptomatic intracerebral hemorrhage occurred in one patient (3.6%). Mortality rate was 0% (0/28) after 3 months. Emergent carotid artery stenting in setting of acute stroke was a safe and effective treatment modality. Successful recanalization (extracranial and intracranial) and absence of intracranial tandem occlusion are significantly associated with a good outcome for our cohort of patients whom undergone emergent carotid artery stenting.

  7. Pseudoaneurysm of the Internal Carotid Artery: Treatment with a Covered Stent

    International Nuclear Information System (INIS)

    Scavee, Vincent; Wispelaere, Jean-Francois de; Mormont, Eric; Coulier, Bruno; Trigaux, Jean-Paul; Schoevaerdts, Jean-Claude

    2001-01-01

    Dissection of the cervical segment of the internal carotid artery may occur spontaneously or after trauma. We report the management of a 53-year-old right-handed man with progressive dizziness and neck pain 6 weeks after a motor vehicle collision. The clinical and neurologic examinations were normal. The CT scan led to the diagnosis of a pseudoaneurysm of the right internal carotid artery near the skull base. We successfully treated this post-traumatic lesion with a covered stent. The patient underwent the endovascular procedure under general anesthesia and transcranial Doppler monitoring. No neurologic event was observed. Obliteration of the pseudoaneurysm with preservation of the carotid artery was achieved. The patient was discharged from the hospital 72 hr later with no complications. Clinical and imaging follow-up at 6 months was unremarkable

  8. Efficacy of a Self-Expandable Porous Stent as the Sole Curative Treatment for Extracranial Carotid Pseudoaneurysms.

    Science.gov (United States)

    Chen, Peng Roc; Edwards, Nancy J; Sanzgiri, Aditya; Day, Arthur L

    2016-04-01

    Extracranial carotid pseudoaneurysms are uncommon vascular lesions. Even with conservative management complications can happen, such as delayed cerebral embolization or symptoms due to flow limitation. Although endovascular therapy can be curative, literature demonstrating a preferred technique is scant. Our goal was to evaluate the use of 1 technique only-the deployment of overlapping self-expandable porous stents-to treat a series of extracranial carotid pseudoaneurysms. From 2008 to 2014, 14 consecutive cases of symptomatic extracranial carotid pseudoaneurysms were managed with single or multilayer porous stents at our institution. Each patient underwent a standardized angiographic follow-up at 6 months. Twelve patients also received a follow-up computed tomography angiogram at 12 months, and yearly thereafter (median radiographic follow-up, 38 months). The total clinical follow-up period ranged between 6 and 69 months (median, 46 months). In our series, each of the extracranial carotid pseudoaneurysms appeared to be the result of carotid artery dissection with associated carotid stenosis at the origin of every pseudoaneurysm. Endovascular treatment consisted of 1-3 layers of self-expandable porous stents placed without balloon angioplasty. Immediately after stenting angiographic images were notable for stagnant opacification of the pseudoaneurysm through the stent(s). All pseudoaneurysms were completely obliterated by the 6-month follow-up angiogram and remained so throughout the radiographic follow-up period. Complications were minimal, consisting of 1 patient developing a mild Horner's syndrome after treatment that resolved during clinical follow-up. Extracranial carotid pseudoaneurysms can be successfully obliterated with the use of porous, self-expandable stents. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Leptomeningeal collateral vessels are a major risk factor for intracranial hemorrhage after carotid stenting in patients with carotid atherosclerotic plaque.

    Science.gov (United States)

    Lee, Kang Ji; Kwak, Hyo Sung; Chung, Gyung Ho; Song, Ji Soo; Hwang, Seung Bae

    2016-05-01

    To evaluate the relationship between leptomeningeal collaterals and intracranial hemorrhage (ICH) after carotid artery stenting (CAS). A retrospective study was undertaken of 228 patients (median age 75 years (range 44-90); 187 men and 41 women) who underwent CAS due to unilateral carotid atherosclerotic plaque from January 2009 to December 2013. Cerebral angiographic findings were classified into three patterns: type I, normal visualization of the anterior and middle cerebral arteries without leptomeningeal collaterals; type II, visualization of the middle cerebral artery only without leptomeningeal collaterals; and type III, visualization of leptomeningeal collateral flow. For all cerebral angiographic findings, 146 (64.0%) were type I, 61 (26.8%) were type II, and 21 (9.2%) were type III. Four patients (1.8%) died with fatal ICH after CAS and had type III angiographic findings (19%). The prevalence of ICH in patients with leptomeningeal collateral vessels was significantly higher than in patients without leptomeningeal collateral vessels (19% vs 0%, pcollateral vessels are a major risk factor for ICH after CAS in patients with carotid atherosclerotic plaque. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Carotid Stenting in Patients With High Risk Versus Standard Risk for Open Carotid Endarterectomy (REAL-1 Trial).

    Science.gov (United States)

    De Haro, Joaquin; Michel, Ignacio; Bleda, Silvia; Cañibano, Cristina; Acin, Francisco

    2017-07-15

    Carotid stenting (CAS) has been mainly offered to those patients considered at "high risk" for open carotid endarterectomy based on available data from large randomized clinical trials. However, several recent studies have called medical "high risk" into question for CAS indication. The REAL-1 trial evaluated the safety and perioperative and long-term effectiveness in patients with significant carotid artery stenosis with "high-risk" criteria treated with CAS and proximal protection device (MOMA) compared with those with standard surgical-risk features. This nonrandomized double-arm registry included 125 patients (40% symptomatic), 71 (56%) with "standard-risk" and 54 (44%) with "high-risk" criteria. The primary end point was the cumulative incidence of any major adverse event, a composite of stroke, myocardial infarction, and death within 30 days after the intervention or ipsilateral stroke after 30 days and up to 4 years. There was no significant difference in primary end point rate at 30 days between patients at "standard risk" and those with "high risk" (1.4% vs 1.9% respectively; hazard ratio for "standard risk" 1.1; 95% CI 0.8 to 1.2, p = 0.77) nor estimated 4-year rate of ipsilateral stroke (1.3% vs 1.8%; hazard ratio for "standard risk" 1.05, 95% CI 0.86 to 1.14, p = 0.9). In conclusion, 4-year postprocedure results demonstrated that CAS with proximal device (MOMA) is safe and effective for patients with and without "high-risk" for carotid endarterectomy. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Safety of Early Carotid Artery Stenting after Systemic Thrombolysis: A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Fabrizio Sallustio

    2012-01-01

    Full Text Available Background. Patients with acute ischemic stroke due to internal carotid artery (ICA disease are at high risk of early stroke recurrence. A combination of IV thrombolysis and early carotid artery stenting (CAS may result in more effective secondary stroke prevention. Objective. We tested safety and durability of early CAS following IV thrombolysis in stroke patients with residual stenosis in the symptomatic ICA. Methods. Of consecutive patients treated with IV rtPA, those with residual ICA stenosis ≥70% or 24 hours. The protocol included pre-rtPA MRI and MR angiography, and post-rtPA carotid ultrasound and CT angiography. Stroke severity was assessed by the NIH Stroke Scale (NIHSS. Three- and twelve-month stent patency was assessed by ultrasound. Twelve-month functional outcome was assessed by the modified Rankin Scale (mRS. Results. Of 145 consecutive IV rtPA-treated patients, 6 (4% underwent early CAS. Median age was 76 (range 67–78 years, median NIHSS at stroke onset was 12 (range 9–16 and 7 (range 7-8 before CAS. Median onset-to-CAS time was 48 (range 30–94 hours. A single self-expandable stent was implanted to cover the entire lesion in all patients. The procedure was uneventful in all patients. After 12 months, all patients had stent patency, and the functional outcome was favourable (mRS ≤ 2 in all but 1 patient experiencing a recurrent stroke for new-onset atrial fibrillation. Conclusion. This small case series of a single centre suggests that early CAS may be considered a safe alternative to CEA after IV rtPA administration in selected patients at high risk of stroke recurrence.

  12. Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques.

    Science.gov (United States)

    Fan, Zhenmin; Liu, Xiao; Sun, Anqiang; Zhang, Nan; Fan, Zhanming; Fan, Yubo; Deng, Xiaoyan

    2017-10-01

    Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface-averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. The use of intraoperative monitoring and treatment of symptomatic microemboli in carotid artery stenting: case report and discussion

    Energy Technology Data Exchange (ETDEWEB)

    Rangi, P.S.; Clifton, A. [St Georges Hospital, Department of Neuroradiology, Atkinson Morley Wing, Tooting, London (United Kingdom); Markus, H.S.; Punter, M.N.M. [St Georges University of London, Centre for Clinical Neuroscience, Cranmer Terrace, London (United Kingdom)

    2007-03-15

    Carotid artery stenting is a recently introduced treatment in symptomatic atherosclerotic carotid artery disease with acceptable complication rates. The major risk is perioperative embolic stroke. Transcranial Doppler ultrasonography (TCD) can be used to identify embolic signals and guide therapy. We present a case of symptomatic embolization in a 72-year-old female following carotid stent deployment complicated by haemodynamic changes. Despite concurrent dual antiplatelet medication significant symptomatic embolization occurred even after restoration of the blood pressure, and modulation of the rate of embolization was achieved using dextran-40 guided by TCD monitoring. The patient recovered from an initially profound hemiparesis and dysphasia to minor sensory changes. Microemboli are common following carotid artery stenting and there appears to be a threshold phenomenon associated with prolonged embolization and progression to cerebral infarction. TCD can be used to detect particulate microemboli and therefore may be useful in guiding antithrombotic therapy in this setting. Dextran-40 has been shown to reduce the embolic load following carotid endarterectomy and was used to good effect in this patient in terms of both embolic load and clinical outcome. This is the first case of embolization following carotid stenting successfully treated with dextran-40, and offers a further option for therapeutic intervention in microembolism detected by TCD and stresses the importance of perioperative monitoring of embolic load for postoperative stroke risk. (orig.)

  14. Angiographic follow-up after carotid artery stenting of bifurcation stenosis; Angiographische Verlaufskontrolle nach Stentimplantation zur Behandlung der Karotisbifurkationsstenose

    Energy Technology Data Exchange (ETDEWEB)

    Hauth, E.A.; Forsting, M. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Jansen, C.; Drescher, R.; Mathias, K. [Radiologische Klinik, Klinikum Dortmund (Germany); Schwarz, M. [Neurologische Klinik, Klinikum Dortmund (Germany); Christmann, A. [Fachbereich Statistik, Univ. Dortmund (Germany); Jaeger, H. [Radiologische Klinik, Klinikum Dortmund (Germany); Marien-Hospital Wesel, Praxis fuer Radiologie, Neuroradiologie and Nuklearmedizin (Germany)

    2006-08-15

    Purpose: the purpose of this prospective study was to determine the restenosis grade, the intima hyperplasia and the stent expansion via angiographic follow-up six months after carotid artery stenting. Materials and methods: in 100 patients, angiographic follow-up was performed 5.9 months (range: 2.9 - 11.4 months) after carotid artery stenting. The restenosis grade, the intima hyperplasia and the stent expansion were measured by selective angiography of the treated carotid artery. Results: the mean restenosis grade was 16% (range: 0 - 78%). In 6 of 100 patients (6%), a restenosis grade of > 50% was measured. In 4 patients the restenosis grade was 50 - 70%. In 2 patients the restenosis grade was > 70%. In 91 of 100 patients (91%), the restenosis was localized in the former area of stenosis of the carotid artery, and in 9 of 100 patients (9%), the restenosis was localized in the cranial stent end. The mean grade of intima hyperplasia was 31% (range: 2 - 70%). The mean increase in stent expansion at the time of follow-up was 10% (range: 0 - 59%). No correlation was able to be determined between the grade of stenosis and the grade of restenosis (rho = 0,017, range: -0.180 - 0.213), between the grade of residual stenosis and the grade of restenosis (rho = 0,257, range: 0.064 - 0.431) and between intima hyperplasia and the grade of restenosis (rho = 0,476, range: 0.309 - 0.615). Conclusions: carotid artery stenting is associated with a low incidence of high-grade restenosis 6 months after an intervention. The intima hyperplasia, which can be observed in each Wallstent, is partly compensated by the expansion of the self-expandable stent. Without a correlation between the grade of residual stenosis and the grade of restenosis, low-grade residual stenosis can be accepted. Therefore, we recommend undersized postdilation of the Wallstent. (orig.)

  15. Costs and cost-effectiveness of carotid stenting versus endarterectomy for patients at standard surgical risk: results from the Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST).

    Science.gov (United States)

    Vilain, Katherine R; Magnuson, Elizabeth A; Li, Haiyan; Clark, Wayne M; Begg, Richard J; Sam, Albert D; Sternbergh, W Charles; Weaver, Fred A; Gray, William A; Voeks, Jenifer H; Brott, Thomas G; Cohen, David J

    2012-09-01

    The Carotid Revascularization Endarterectomy versus Stenting Trial (CREST) demonstrated similar rates of the primary composite end point between carotid artery stenting (CAS) and carotid endarterectomy (CEA), although the risk of stroke was higher with CAS, and the risk of myocardial infarction was higher with CEA. Given the large number of patients who are candidates for these procedures, an understanding of their relative cost and cost-effectiveness may have important implications for health care policy and treatment guidelines. We performed a formal economic evaluation alongside the CREST trial. Costs were estimated from all trial participants over the first year of follow-up using a combination of resource use data and hospital billing data. Patient-level health use scores were obtained using data from the SF-36. We then used a Markov disease-simulation model calibrated to the CREST results to project 10-year costs and quality-adjusted life expectancy for the 2 treatment groups. Although initial procedural costs were $1025/patient higher with CAS, postprocedure costs and physician costs were lower such that total costs for the index hospitalization were similar for the CAS and CEA groups ($15 055 versus $14 816; mean difference, $239/patient; 95% CI for difference, -$297 to $775). Neither follow-up costs after discharge nor total 1-year costs differed significantly. For the CREST population, model-based projections over a 10-year time horizon demonstrated that CAS would result in a mean incremental cost of $524/patient and a reduction in quality-adjusted life expectancy of 0.008 years compared with CEA. Probabilistic sensitivity analysis demonstrated that CEA was economically attractive at an incremental cost-effectiveness threshold of $50 000/quality-adjusted life-year gained in 54% of samples, whereas CAS was economically attractive in 46%. Despite slightly lower in-trial costs and lower rates of stroke with CEA compared with CAS, projected 10-year outcomes

  16. Volume and composition of emboli in neuroprotected stenting of the carotid artery.

    Science.gov (United States)

    Piñero, P; González, A; Martínez, E; Mayol, A; Rafel, E; González-Marcos, J R; Moniche, F; Cayuela, A; Gil-Peralta, A

    2009-03-01

    Periprocedural microembolization is a major and permanent risk for patients treated by angioplasty and stent placement of high-grade carotid stenoses. Little is known however about the characteristics and significance of these embolized particles. Our aim was to assess the volume and composition of debris captured by filters during carotid angioplasty and stent placement (CAS) of severe internal carotid artery (ICA) stenoses. Institutional review board approval and informed consent from all subjects were obtained. Two hundred one patients (mean age, 66.2 years; range, 35-82 years) with > or = 70% stenosis of the ICA underwent filter-protected CAS. Ultrastructural and semiquantitative analysis of the volume of filters was obtained. Multifactorial statistical analysis was performed to determine factors related to debris volume and composition. Transient ischemic attack occurred in 6 patients (3%), and a major stroke, in 1 (0.5%). Debris was found in 117 filters (58.2%), with volume <1 lambda (0.001 mL) in 71%. The number of balloon dilations, age older than 65 years, and calcified plaques in pre-CAS angiography were significantly associated with the presence of particulates inside the filters (P < .03, P < .004, and P < .05, respectively). Vessel wall and atheromatous plaques are the main source of microemboli during CAS. Embolization is mainly related to the number of balloon dilations during CAS. Planning a proper and individualized strategy for the procedure in each patient is essential to minimize the potential effects of manipulation during CAS.

  17. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  18. Urgent carotid stenting before cardiac surgery in a young male patient with acute ischemic stroke caused by aortic and carotid dissection

    Directory of Open Access Journals (Sweden)

    Popović Rade

    2016-01-01

    Full Text Available Introduction. Acute aortic dissection (AD is the most common life-threatening disorder affecting the aorta. Neurological symptoms are present in 17-40% of cases. The management of these patients is controversial. Case report. We presented a 37-year-old man admitted for complaining of left-sided weak-ness. Symptoms appeared two hours before admission. The patient had no headache, neither thoracic pain. Neurological examination showed mild confusion, left-sided hemiplegia, National Institutes of Health Stroke Scale (NIHSS score was 10. Ischemic stroke was suspected, brain multislice computed tomography (MSCT and angiography were performed and right intrapetrous internal carotid artery dissection noted. Subsequent color Doppler ultrasound of the carotid arteries showed dissection of the right common carotid artery (CCA. The patient underwent thoracic and abdominal MSCT aortography which showed ascending aortic dissection from the aortic root, propagating in the brachiocephalic artery and the right CCA. Digital subtraction angiography was performed subsequently and two stents were successfully implanted in the brachiocephalic artery and the right CCA prior to cardiac surgery, only 6 hours after admission. The ascending aorta was reconstructed with graft interposition and the aortic valve re-suspended. The patient was hemodynamically stable and with no neurologic deficit after surgery. Unfortinately, at the operative day 6, mediastinitis developed and after intensive treatment the patients died 35 days after admission. Conclusion. In young patients with suspected stroke and oscillatory neurological impairment urgent MSCT angiography of the brain and neck and/or Doppler sonography of the carotid and vertebral artery are mandatory to exclude carotid and aortic dissection. The prompt diagnosis permits urgent carotid stenting and cardiosurgery. To the best of our knowledge, this is the first published case of immediate carotid stenting in acute ischemic

  19. Endovascular treatment with angioplasty or stenting versus endarterectomy in patients with carotid artery stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): long-term follow-up of a randomised trial.

    LENUS (Irish Health Repository)

    Ederle, Jörg

    2009-10-01

    Endovascular treatment (angioplasty with or without stenting) is an alternative to carotid endarterectomy for carotid artery stenosis but there are scarce long-term efficacy data showing that it prevents stroke. We therefore report the long-term results of the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS).

  20. Hybrid treatment of tandem, common carotid/innominate artery and ipsilateral carotid bifurcation stenoses by simultaneous, retrograde proximal stenting and eversion carotid endarterectomy: Preliminary results of a case series.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Pasqua, Rocco; Frezzotti, Francesca; Palumbo, Piergaspare; Macrina, Francesco; Calio', Francesco

    2018-04-01

    Tandem stenoses of the internal carotid artery (ICA) and proximal, ipsilateral common carotid artery (CCA) or innominate artery can be treated with a hybrid approach, combining conventional carotid endarterectomy (CEA) and retrograde stenting of the proximal stenosis, through surgical exposure of the carotid bifurcation. The purpose of this study was to evaluate the results of combining eversion CEA with retrograde CCA/innominate artery stenting. From January 2015 to July 2017, 7 patients, 6 men of a mean age of 72 years (range 59-83 years) underwent simultaneous, retrograde stenting of the proximal CCA/innominate artery and an eversion CEA of the ipsilateral ICA, through surgical exposure of the carotid bifurcation, for severe tandem stenoses. The proximal stenosis involved the left proximal CCA in 4 patients, the proximal innominate artery in 2 patients and the right CCA in one patient. The procedure was performed under general anesthesia in a conventional operating room equipped with a mobile C-arm. A covered, balloon expandable stent was deployed over the proximal stenosis via a 6-F sheath directly introduced into the proximal CCA through the obliquely transected carotid bulb. After removing the sheath, debris were flushed through the carotid bulb and eversion CEA completed the procedure. Study endpoints were: postoperative stroke/mortality rate, cardiac mortality and morbidity, peripheral nerve injury, cervical hematoma, overall late survival, freedom from ipsilateral stroke and patency of arterial reconstruction. No postoperative mortality or neurologic morbidity was observed in any patient. Cervical hematomas and peripheral nerve injuries were likewise absent. At a mean follow-up of 18 months, all the patients were alive, free from neurologic events of new onset and free from restenosis. Combined proximal stenting and eversion CEA for tandem lesions seems a valid treatment, with the advantages of eversion CEA over other techniques of carotid bifurcation

  1. Stent-protected angioplasty versus carotid endarterectomy in patients with carotid artery stenosis: meta-analysis of randomized trial data

    International Nuclear Information System (INIS)

    Wiesmann, Martin; Schoepf, Veronika; Brueckmann, Hartmut; Jansen, Olav

    2008-01-01

    Stent-protected angioplasty of carotid artery stenosis may be an alternative to surgical endarterectomy. Results published so far are indecisive, with evidence both in favour of and against this procedure. After the recent publication of two large European multicentre trials (SPACE and EVA-3S) almost 3,000 patients have been included in randomized studies. For this report, we therefore conducted a systematic review of randomized studies that compared endovascular treatment with surgery for carotid stenosis. We evaluated seven trials including 2,973 patients. In our meta-analysis endovascular treatment seemed to carry a slightly higher risk for stroke or death within 30 days after the procedure as compared with surgery (8.2% vs. 6.2%; p = 0.04; OR 1.35), whereas the rates of disabling stroke or death within 30 days did not differ significantly (p = 0.47; n.s.). On the other hand, surgery carried a significantly higher risk for cranial nerve palsy (4.7% vs. 0.2%; p < 0.0001; OR 0.17) and myocardial infarction (2.3% vs. 0.9%; p = 0.03; OR 0.37). Long-term effects of both methods still need to be evaluated. Two other large multicentre trials (ICSS and CREST) are ongoing. Results of these studies will increase the database to about 7,000 randomized patients. Future meta-analyses should then allow definitive treatment recommendations. (orig.)

  2. Treatment of carotid-siphon aneurysms by using willis stent-graft: an angiographic and histopathologic study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Xie Jian; Tan Huaqiao; Cheng Yingsheng; Wang Jianbo

    2010-01-01

    Objective: To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months. Methods: Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs (group A) and 12 carotid siphon aneurysms in another twelve dogs (group B). A Willis stent-graft was implanted in each aneurysm. Angiography was performed immediately after the procedure and 1, 3, 6 and 12 months after the implantation to investigate the aneurysm isolation, endoleak, stent angulation, and the patency or restenosis of the parent artery. Light and scanning electronic microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress of the stent-loaded arterial segment. Results: In group B, postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated. Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared, one parent artery became occluded and three parent arteries developed mild stenosis (< 50%). In group A, occlusion of parent artery was seen in one and mild stenosis (< 50%) in 2 cases. Electronic microscopy revealed new intima formation in all stents, and all aneurysmal sacs were filled with thrombi. In group B, the endothelialization process was not completed until 12 months after the stent implantation, and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation. Conclusion: It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft. The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel. (authors)

  3. Prosthetic bypass for restenosis after endarterectomy or stenting of the carotid artery.

    Science.gov (United States)

    Illuminati, Giulio; Belmonte, Romain; Schneider, Fabrice; Pizzardi, Giulia; Calió, Francesco G; Ricco, Jean-Baptiste

    2017-06-01

    The objective of this study was to evaluate the results of prosthetic carotid bypass (PCB) with polytetrafluoroethylene (PTFE) grafts as an alternative to carotid endarterectomy (CEA) in treatment of restenosis after CEA or carotid artery stenting (CAS). From January 2000 to December 2014, 66 patients (57 men and 9 women; mean age, 71 years) presenting with recurrent carotid artery stenosis ≥70% (North American Symptomatic Carotid Endarterectomy Trial [NASCET] criteria) were enrolled in a prospective study in three centers. The study was approved by an Institutional Review Board. Informed consent was obtained from all patients. During the same period, a total of 4321 CEAs were completed in the three centers. In these 66 patients, the primary treatment of the initial carotid artery stenosis was CEA in 57 patients (86%) and CAS in nine patients (14%). The median delay between primary and redo revascularization was 32 months. Carotid restenosis was symptomatic in 38 patients (58%) with transient ischemic attack (n = 20) or stroke (n = 18). In this series, all patients received statins; 28 patients (42%) received dual antiplatelet therapy, and 38 patients (58%) received single antiplatelet therapy. All PCBs were performed under general anesthesia. No shunt was used in this series. Nasal intubation to improve distal control of the internal carotid artery was performed in 33 patients (50%), including those with intrastent restenosis. A PTFE graft of 6 or 7 mm in diameter was used in 6 and 60 patients, respectively. Distal anastomosis was end to end in 22 patients and end to side with a clip distal to the atherosclerotic lesions in 44 patients. Completion angiography was performed in all cases. The patients were discharged under statin and antiplatelet treatment. After discharge, all of the patients underwent clinical and Doppler ultrasound follow-up every 6 months. Median length of follow-up was 5 years. No patient died, sustained a stroke, or presented with a

  4. Stenting of the cervical internal carotid artery in acute stroke management: The Karolinska experience.

    Science.gov (United States)

    Mpotsaris, Anastasios; Kabbasch, Christoph; Borggrefe, Jan; Gontu, Vamsi; Soderman, Michael

    2017-04-01

    Background Emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy is a routine procedure. Yet, precise indications and clinical safety in this setting remains controversial. Present data for mechanical thrombectomy include few studies with acute stenting of tandem occlusions. We evaluated the feasibility, safety and clinical outcome of this endovascular treatment in a retrospective analysis of all consecutive cases at a comprehensive stroke centre. Methods This was a retrospective analysis of all consecutive patients with acute extracranial carotid artery occlusion including acute dissection or high-grade stenosis and concomitant intracranial large-vessel occlusion treated with emergency carotid stenting and intracranial mechanical thrombectomy between November 2007 and May 2015. Results A total of 63 patients with a median age of 67 years (range 33-84 years) were treated. Of these, 33 (52%) patients had concomitant intravenous thrombolysis with recombinant tissue-type plasminogen activator initially. Median admission National Institutes of Health Stroke Scale was 14 (range 1-29). Median time from stroke onset to recanalization was 408 minutes (range 165-1846 minutes). Procedure time was significantly shorter after intravenous thrombolysis (110 minutes [range 15-202 minutes] vs. 130 minutes [range 60-280 minutes]; p = 0.02). Three (5%) patients experienced post-procedural symptomatic intracerebral haemorrhage. In 55/63 (87%) patients, a score of ≥2b on the Thrombolysis in Cerebral Infarction scale could be achieved. Eight (13%) patients died, five (8%) during the acute phase. A total of 29/63 (46%) patients showed a favourable outcome (modified Rankin Scale score of 0-2) after three months. Conclusions Our single-centre retrospective analysis of emergency stent placement in the extracranial internal carotid artery in combination with anterior circulation thrombectomy demonstrated high

  5. Preliminary clinical application in the cranial internal carotid artery of covered stents specially designed for intracranial vasculature

    International Nuclear Information System (INIS)

    Li Minghua; Luo Qiyi; Fang Chun; Xie Zhiyong; Cheng Yingsheng; Gao Bulang; Li Yu; Zhang Beilei; Xie Jian; Wang Yongli

    2007-01-01

    Objective: To investigate the flexibility of both the covered stents specially designed for use in intracranial vasculature and the delivering system in passing through the bone tube and the physiological curves of the cranial internal carotid artery (CICA) to reach the targeted area, the performance (adherence) of the covered stents in occluding vascular wall diseases and the impact on the vascular branches of the covered segment. Methods: The covered stents specially designed for use in intracranial vasculature were used to treat 13 patients with CICA diseases using endovascular techniques. There were 4 huge pseudoaneurysms, 4 giant aneurysms, 3 small wide-necked aneurysms, 1 giant pseudoaneurysm with concurrent internal carotid cavernous fistula (CCF), and 1 CCF. Prior to the detachment of the covered stents, balloon occlusion test (BOT) of the internal carotid artery on the diseased side and whole-brain digital subtraction angiography (DSA) were performed in all the patients. Three to 16 months following procedure, DSA and clinical follow-ups were performed. Results: Thirteen patients all tolerated the BOT well with the DSA demonstrating well-opened anterior and posterior communicating arteries. The covered stents and the delivering systems all successfully passed CICA to reach the targeted diseased area, with the diseased segments of the internal carotid artery including C3-C4 in 4 cases, C4-C5 in 4 and C6-C7 in 5. Immediately following the detachment of the covered stents, DSA demonstrated that 7 aneurysms were completely occluded, 4 aneurysms had slight endoleak, and 1 CCF had markedly-decreased blood flow through the fistula. In the patient with concurrent pseudoaneurysm and CCF, the pseudoaneurysm disappeared and the blood flow through the fistula was markedly-reduced immediately following the stenting procedure. Apart from one patient with aneurysmal subarachnoid hemorrhage who died due to extensive vascular spasm on the 9th day following the stenting

  6. Flow-diverting Stent in the Treatment of Cervical Carotid Dissection and Pseudoaneurysm: Review of Literature and Case Report.

    Science.gov (United States)

    Baptista-Sincos, Anna Paula Weinhardt; Simplício, Aline Bigatão; Sincos, Igor Rafael; Leaderman, Alex; Neto, Fernando Saliture; Moraes, Adjaldes; Aun, Ricardo

    2018-01-01

    The endovascular technique has been recommended over the past few years to extracranial carotid dissection and pseudoaneurysm with promising results, especially after medical therapy failure. Flow-diverting stents are an alternative for complex cases. These stents have proven to be effective treatment devices for intracranial aneurysms. The reference list of Pham's systematic review, published in 2011, and Seward's literature review, published in 2015, was considered, as well as all new articles with eligible features. Search was conducted on specific databases: MEDLINE and Literatura Latino-Americana e do Caribe em Ciências da Saúde. For carotid dissection and pseudoaneurysm, our review yielded 3 published articles including 12 patients. The technical success rate of flow-diverting stent was 100% with no procedural complication described. Mean clinical follow-up was 27.2 months (range 5-48), and in 5 months' angiographic follow-up, all lesions had healed. No new neurological events were reported during the clinical follow-up. Flow diverter stent use on intracranial and peripheral vascular surgery demonstrates satisfactory initial results, but it is still under investigation. There are very few cases treated till now and the initial results with flow-diverting stents to cervical carotid dissection are promising. In well-selected cases, where simple embolization or conventional stent is not appropriate, this technic may be considered. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Thirty-day outcomes of direct carotid artery stenting with cerebral protection in high-risk patients

    International Nuclear Information System (INIS)

    Veselka, J.; Cerna, D.; Zimolova, P.; Blasko, P.; Fiedler, J.; Hajek, P.; Maly, M.; Zemanek, D.; Duchonova, R.

    2007-01-01

    Implantation of a carotid artery stent after predilation is a standard approach in the endovascular treatment of carotid artery stenoses. Stenting without predilation may be an alternative approach in a certain subset of patients. The present prospective, single-center registry was designed to evaluate the feasibility and safety of direct carotid artery stenting (DCAS) in high-risk patients. Symptomatic patients with stenosis >50% and asymptomatic patients with stenosis >70% were eligible for enrolment. Criteria for high-risk patients included: need or history of open heart surgery, history of myocardial infarction, multivessel coronary artery disease, left ventricular dysfunction (ejection fraction ≤40%), severe pulmonary or renal disease, significant contralateral carotid disease, previous endarterectomy, and age ≥80 years. All procedures were performed using a filter protection device. Patients underwent complete clinical examination before and after DCAS and at 30-day follow-up. A total of 83 consecutive patients (45 males, 68±9 years, 33% symptomatic) underwent 100 procedures and 103 stents were deployed successfully. The technical success rate of stenting was 100%. Predilation of carotid stenosis was necessary in 1 (1%) procedure. Carotid-artery stenoses before and after DCAS were 80±9% and 7±9%, respectively. The median fluoroscopic time for DCAS was 7 min. The overall rate of in-hospital major adverse cerebrovascular events (death, stroke, myocardial infarction) was 5% (2 minor strokes, 3 transient attacks). There was 1 (1%) minor stroke within the 30-day follow-up. DCAS is feasible and can be performed with an acceptable risk in high-risk patients. (author)

  8. [Changes of brain function and cognitive function after carotid artery stenting].

    Science.gov (United States)

    Lu, Z X; Deng, G; Wei, H L; Zhao, G F; Wen, L Z; Chen, X

    2017-10-24

    Objective: To investigate the effect of carotid artery stenting(CAS) on cognitive function and brain function based on changes of a battery of neuropsychological tests and magnetic resonance imaging. Methods: Thirty-three patients were included with 17 in the stent-placement group and 16 in the control group (receiving medical treatment), among whom, the unilateral or bilateral severe internal carotid artery stenosis was confirmed by cerebral vascular angiography in the department of Interventional Radiology and Vascular Surgery of Zhongda Hospital Southeast University from June 2015 to September 2016.Neuropsychological tests and rest-state blood oxygenation level dependent fMRI were performed at the baseline and six months follow-up.The baseline characteristics and follow-up changes were compared in each group. Results: The overall cognitive function of the stent-placement group was statistically significantly improved ( P function, memory, attention and other aspects.The value of amplitude of low-frequency fluctuation(ALFF) showed statistically significant increase ( P left prefrontal cortex ( t =5.861 3, P left superior parietal lobe( t =5.601 2, P left retrosplenial cingulate cortex( t =-5.590 4, P left insular cortex ( t =-6.340 8, P right insular cortex ( t =-8.129 9, P left dorsal anterior cingulate cortex ( t =-5.584 8, P 0.05, Alphasim correction)between baseline and follow-up results in control group.Besides, the ALFF changes of the left insular cortex ( r =-0.591, P =0.033) and bilateral motor cortical area ( r =-0.659, P =0.014) were negatively correlated with auditory verb learning test (AVLT) score changes.The ALFF change of bilateral motor cortical area was negatively correlated with the AVLT-delay score change ( r =-0.588, P =0.034). And the ALFF change on right insular cortex and the frontal assessment battery (FAB) score change was positively correlated ( r =0.638, P =0.025). Conclusions: The overall cognitive function of patients with carotid

  9. Cerebral ischemia after filter-protected carotid artery stenting is common and cannot be predicted by the presence of substantial amount of debris captured by the filter device.

    Science.gov (United States)

    Maleux, G; Demaerel, P; Verbeken, E; Daenens, K; Heye, S; Van Sonhoven, F; Nevelsteen, A; Wilms, G

    2006-10-01

    Protected carotid artery stent placement is currently under clinical evaluation as a potential alternative to carotid endarterectomy. The current study was undertaken to determine the incidence of new ischemic lesions found on diffusion-weighted MR imaging (DWI) in nonselected patients after protected carotid artery stent placement using a filter device and to determine the potential relationship between these new ischemic lesions and the presence or absence of a clear amount of debris captured by the neuroprotection filter device. A nonrandomized cohort of 52 patients (40 men, 12 women) presenting with carotid occlusive disease underwent protected carotid artery stent placement using a filter device. DWI obtained 1 day before stent placement was compared with that obtained 1 day after stent placement. In addition, the macroscopic and microscopic analysis of debris captured by the filter device during the carotid stent placement procedure was assessed. Neuroprotected carotid stent placement was technically successful in all 53 procedures but was complicated by a transient ischemic attack in 3 patients (5.6%). In 22 patients (41.5%), new ischemic lesions were found on DWI, and in 21 filter devices (39.6%), a substantial amount of atheromatous plaque and/or fibrin was found. No clear relationship between the presence of debris captured by the filter device and new lesions detected by DWI was found (P = .087; odds ratio 3.067). Neuroprotected carotid artery stent placement will not avoid silent cerebral ischemia. Systematic microscopic analysis of debris captured by the filter device has no predictive value for potential cerebral ischemia after carotid artery stent placement.

  10. Cerebral protection devices for use during carotid artery angioplasty with stenting: a health technology assessment.

    Science.gov (United States)

    Menon, Devidas; Stafinski, Tania

    2006-01-01

    This study sought to examine the safety, efficacy, and economic implications of the use of cerebral protection devices during carotid artery angioplasty and stenting (CAS) in high-risk patients with severe carotid artery disease (CAD). A comprehensive search for peer- and non-peer-reviewed studies that compared carotid endarterectomy (CEA) or CAS without cerebral protection to CAS with cerebral protection and appeared in the English language literature between January 1990 and January 2005 was completed. Information from studies identified was extracted using a common data abstraction form and then critically appraised against published quality assessment criteria. Of the eight studies found, six provided information on technical or procedural success rates, with values ranging from 95.6 percent to 100 percent. Three of the four studies comparing groups of patients who received CAS with cerebral protection with those who received only CAS reported a non-statistically significantly higher 30-day incidence of death and stroke (major or minor) in the latter group. None of the three studies comparing CAS with cerebral protection to CEA demonstrated a statistically significant difference in the 30-day incidence of death, major stroke, or myocardial infarction between treatment groups. No economic analyses were found. In high-risk patients with severe CAD, the evidence suggests that CAS with cerebral protection may offer a safe and efficacious alternative to CEA, reducing the risk of embolic peri-procedural complications associated with CAS to acceptable levels.

  11. Carotid Stenting with Distal Protection in High-Surgical-Risk Patients: One-Year Results of the ASTI Trial

    Energy Technology Data Exchange (ETDEWEB)

    Bosiers, Marc, E-mail: marc.bosiers@telenet.be [A.Z. Sint-Blasius, Department of Vascular Surgery (Belgium); Scheinert, Dierk, E-mail: dierk.scheinert@gmx.de [Park Hospital, Center for Vascular Medicine-Angiology and Vascular Surgery (Germany); Mathias, Klaus, E-mail: k.mathias@asklepios.com [Klinikum Dortmund GmbH (Germany); Langhoff, Ralf, E-mail: ralf.langhoff@sankt-gertrauden.de [Sankt Gertrauden-Krankenhaus (Germany); Mudra, Harald, E-mail: haraldmudra@aol.com [Klinikum Neuperlach (Germany); Diaz-Cartelle, Juan, E-mail: juan.diazcartelle@bostonscientific.com [One Boston Scientific Place, Boston Scientific Corporation (United States)

    2015-04-15

    PurposeThis prospective, multicenter, nonrandomized study evaluated the periprocedural and 1-year outcomes in high-surgical-risk patients with carotid artery stenosis treated with the Adapt Carotid Stent plus FilterWire EZ distal protection catheter (Boston Scientific Corporation, Natick, MA).Materials and MethodsThe study enrolled 100 patients (32 symptomatic, 63 asymptomatic, 5 unknown) at high risk for carotid endarterectomy due to prespecified anatomical criteria and/or medical comorbidities. Thirty-day and 1-year follow-up included clinical evaluation, carotid duplex ultrasound, and independent neurologic and NIH stroke scale assessments. One-year endpoints included the composite rate of major adverse events (MAE), defined as death, stroke, and myocardial infarction (MI) and the rates of late ipsilateral stroke (31–365 days), target lesion revascularization, and in-stent restenosis.ResultsOf the 100 enrolled patients, technical success was achieved in 90.9 % (90/99). The 30-day MAE rate (5.1 %) consisted of major stroke (2.0 %) and minor stroke (3.1 %); no deaths or MIs occurred. The 1-year MAE rate (12.2 %) consisted of death, MI, and stroke rates of 4.4, 3.3, and 8.9 %, respectively. Late ipsilateral stroke (31–365 days) rate was 1.1 %. Symptomatic patients had higher rates of death (11.1 vs. 1.7 %) and MI (7.4 vs. 1.7 %), but lower rates of major (7.4 vs. 10.0 %) and minor stroke (0.0 vs. 6.7 %), compared with asymptomatic patients.ConclusionResults through 1 year postprocedure demonstrated that carotid artery stenting with Adapt Carotid Stent and FilterWire EZ is safe and effective in high-risk-surgical patients.

  12. Carotid Stenting with Distal Protection in High-Surgical-Risk Patients: One-Year Results of the ASTI Trial

    International Nuclear Information System (INIS)

    Bosiers, Marc; Scheinert, Dierk; Mathias, Klaus; Langhoff, Ralf; Mudra, Harald; Diaz-Cartelle, Juan

    2015-01-01

    PurposeThis prospective, multicenter, nonrandomized study evaluated the periprocedural and 1-year outcomes in high-surgical-risk patients with carotid artery stenosis treated with the Adapt Carotid Stent plus FilterWire EZ distal protection catheter (Boston Scientific Corporation, Natick, MA).Materials and MethodsThe study enrolled 100 patients (32 symptomatic, 63 asymptomatic, 5 unknown) at high risk for carotid endarterectomy due to prespecified anatomical criteria and/or medical comorbidities. Thirty-day and 1-year follow-up included clinical evaluation, carotid duplex ultrasound, and independent neurologic and NIH stroke scale assessments. One-year endpoints included the composite rate of major adverse events (MAE), defined as death, stroke, and myocardial infarction (MI) and the rates of late ipsilateral stroke (31–365 days), target lesion revascularization, and in-stent restenosis.ResultsOf the 100 enrolled patients, technical success was achieved in 90.9 % (90/99). The 30-day MAE rate (5.1 %) consisted of major stroke (2.0 %) and minor stroke (3.1 %); no deaths or MIs occurred. The 1-year MAE rate (12.2 %) consisted of death, MI, and stroke rates of 4.4, 3.3, and 8.9 %, respectively. Late ipsilateral stroke (31–365 days) rate was 1.1 %. Symptomatic patients had higher rates of death (11.1 vs. 1.7 %) and MI (7.4 vs. 1.7 %), but lower rates of major (7.4 vs. 10.0 %) and minor stroke (0.0 vs. 6.7 %), compared with asymptomatic patients.ConclusionResults through 1 year postprocedure demonstrated that carotid artery stenting with Adapt Carotid Stent and FilterWire EZ is safe and effective in high-risk-surgical patients

  13. Combined application of distal and proximal embolic protection devices in endovascular stenting for severe carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Zhi-hua DU

    2011-09-01

    Full Text Available Objective To analyze and summarize methods and experiences of combined application of distal and proximal embolic protection devices(EPD in endovascular stenting for severe carotid artery stenosis.Methods Five patients with severe stenosis of the common carotid artery or with extracranial segment of the internal carotid artery diagnosed through digital subtraction angiography(DSA from March to July 2010 were involved in the present study.All patients received carotid angioplasty and stenting(CAS,with a combination of distal and proximal EPD via the percutaneous femoral artery approach.Results The operation failed in one patient,whereas technical success with no intraoperative complication was achieved in four patients.The symptoms disappeared or improved in the four cases that achieved technical success.The follow-up duration was one to three months,and no cerebral ischemia was found.Conclusion CAS with the combined application of distal and proximal EPD in some special cases of carotid artery stenosis may surmount the shortage of single EPD,reduce the risk of intraoperative embolization,decrease the time of intraoperative endovascular inflow occlusion,and reduce high-risk operations.CAS may be used as an individualized treatment strategy for patients with carotid artery stenosis.

  14. EFFECT OF STENT ABSORBED c-myc ANTISENSE OLIGODEOXYNUCLEOTIDE ON SMOOTH MUSCLE CELLS APOPTOSIS IN RABBIT CAROTID ARTERY

    Institute of Scientific and Technical Information of China (English)

    张新霞; 崔长琮; 李江; 崔翰斌; 徐仓宝; 朱参战

    2002-01-01

    Objective To investigate the effect of gelatin coated Platinium-Iridium stent absorbed c-myc antisense oligodeoxynucleotide (ASODN) on smooth muscle cells apoptosis in a normal rabbit carotid arteries. Methods Gelatin coated Platinium-Iridium stents were implanted in the right carotid arteries of 32 rabbits under vision. Animals were randomly divided into control group and treated group receiving c-myc ASODN (n=16, respectively). On 7, 14, 30 and 90 days following the stenting procedure ,morphometry for caculation of neointimal area and mean neointimal thickness were performed.The expression of c-myc protein was detected by immunohistochemical method. Apoptotic smooth muscle cells was detected by terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL). Results At 7 and 14 days after stenting,there were no detectable apoptotic cells in both groups. The apoptotic cells occurred in the neointima 30 and 90 days after stenting, and the number of apoptotic cells at 30 days were less [4.50±1.29 vs 25.75±1.89 (number/0.1mm2)] than that at 90 days [13.50±1.91 vs 41.50±6.46 (number/0.1mm2)]. Meanwhile c-myc ASODN induced more apoptotic cells than the control group(P<0.0001). c-myc protein expression was weak positive or negative in treated group and positive in control group.Conclusion c-myc ASODN can induce smooth muscle cells apoptosis after stenting in normal rabbit carotid arteries,and it can be used to prevent in-stent restenosis.

  15. Outcomes of early carotid stenting and angioplasty in large-vessel anterior circulation strokes treated with mechanical thrombectomy and intravenous thrombolytics.

    Science.gov (United States)

    Mehta, T; Desai, N; Mehta, K; Parikh, R; Male, S; Hussain, M; Ollenschleger, M; Spiegel, G; Grande, A; Ezzeddine, M; Jagadeesan, B; Tummala, R; McCullough, L

    2018-01-01

    Introduction Proximal cervical internal carotid artery stenosis greater than 50% merits revascularization to mitigate the risk of stroke recurrence among large-vessel anterior circulation strokes undergoing mechanical thrombectomy. Carotid artery stenting necessitates the use of antiplatelets, and there is a theoretical increased risk of hemorrhagic transformation given that such patients may already have received intravenous thrombolytics and have a significant infarct burden. We investigate the outcomes of large-vessel anterior circulation stroke patients treated with intravenous thrombolytics receiving same-day carotid stenting or selective angioplasty compared to no carotid intervention. Materials and methods The study cohort was obtained from the National (Nationwide) Inpatient Sample database between 2006 and 2014, using International Statistical Classification of Diseases, ninth revision discharge diagnosis and procedure codes. A total of 11,825 patients with large-vessel anterior circulation stroke treated with intravenous thrombolytic and mechanical thrombectomy on the same day were identified. The study population was subdivided into three subgroups: no carotid intervention, same-day carotid angioplasty without carotid stenting, and same-day carotid stenting. Outcomes were assessed with respect to mortality, significant disability at discharge, hemorrhagic transformation, and requirement of percutaneous endoscopic gastronomy tube placement, prolonged mechanical ventilation, or craniotomy. Results This study found no statistically significant difference in patient outcomes in those treated with concurrent carotid stenting compared to no carotid intervention in terms of morbidity or mortality. Conclusions If indicated, it is reasonable to consider concurrent carotid stenting and/or angioplasty for large-vessel anterior circulation stroke patients treated with mechanical thrombectomy who also receive intravenous thrombolytics.

  16. Mesh-covered (Roadsaver stent as a new treatment modality for symptomatic or high-risk carotid stenosis

    Directory of Open Access Journals (Sweden)

    Roman Machnik

    2017-05-01

    Full Text Available Introduction : Prevention of periprocedural stroke has a crucial role in carotid artery stenting (CAS procedures. Aim : To assess retrospectively 30-day safety and effectiveness of 41 procedures of internal and common carotid artery stenting using the Roadsaver double nitinol layer micromesh stent in 40 non-consecutive patients with symptomatic or high-risk carotid artery stenosis. Material and methods : The patients were men (n = 31 and women (n = 9; mean age was 67.8 ±7.9 years. Femoral access was used in 39 cases, whereas radial access was used in 2. Proximal (n = 27 or distal (n = 14 embolic neuroprotection was used. Results : The Roadsaver stents (nominal diameter 7, 8 or 9 mm, length 25 or 30 mm were implanted successfully in all cases. One minor stroke occurred after common carotid artery intubation with a guiding catheter (before stent deployment and one transient postprocedural ischemic attack (TIA of the ipsilateral cerebral hemisphere was observed. Internal/common carotid artery stenosis severity was evaluated by duplex Doppler. Maximal peak systolic velocity (PSV before CAS was in the range: 2.0–7.0 m/s, mean: 3.9 ±1.0 m/s, at 24–48 h after stenting mean PSV was 1.1 ±0.4 m/s (p < 0.05, and at 30 days 1.1 ±0.3 m/s (p < 0.05. Maximal end-diastolic velocity (EDV was 0.85–3.5 m/s, mean 1.4 ±0.5 m/s, at 24–48 h after stenting mean EDV was 0.3 ±0.1 m/s (p < 0.05, and at 30 days 0.4 ±0.1 m/s (p < 0.05. No restenosis or thrombosis was observed. Angiographic stenosis decreased from 82.9 ±9.1% (range: 61–97% to 19.3 ±7.3% (range: 0–34% (p < 0.05. Conclusions : The CAS using the Roadsaver stent seems to be safe and effective. Further studies involving larger patient populations and longer follow-up are needed.

  17. Clinical application of transvenous temporary cardiac pacemaker in performing extra-cranial carotid angiography and stent implantation

    International Nuclear Information System (INIS)

    Liu Juan; Yao Guoen; Zhou Huadong; Jiang Xiaojiang; Chen Qiao

    2012-01-01

    Objective: To assess the safety and effectiveness of transvenous temporary cardiac pacemaker in preventing hemodynamic instability occurred during the perioperative period of extra-cranial carotid angiography and stent implantation. Methods: Preoperative install of temporary cardiac pacemaker via left femoral vein was carried out in 41 patients who were at high risk for developing hemodynamic instability, which was followed by extra-cranial carotid angiography and stent implantation. The pacing rhythm of the pacemaker was fixed at 60 beats/min. During and after the procedure the patients were under close observation for the signs of discomfort symptoms as well as the changes in blood pressure and heart rate. The working condition of the pacemaker was also monitored. Results: All the installed pacemakers were technically and hemodynamically effective in producing electrical ventricular responses in all 25 patients who had received balloon dilatation of carotid in advance. Transient pacemaker activation appeared in 25 patients. The longest activation time was one day. During pacemaker activation, one patient developed symptomatic hypotension. The longest duration of hypotension lasted for 4 days. No pacemaker-related or procedure-related complications occurred. Conclusion: Hemodynamic instability is a common complication occurred during perioperative period of extra-cranial carotid angiography and stent implantation. As a prophylactic measure, preoperative placement of temporary cardiac pacemaker can promptly and effectively correct the hemodynamic disorders and prevent perioperative complications such as stroke, etc. Therefore, this technique is worth employing in clinical practice, and it is especially useful for patients with high risks. (authors)

  18. The CLEAR-ROAD study: evaluation of a new dual layer micromesh stent system for the carotid artery.

    Science.gov (United States)

    Bosiers, Marc; Deloose, Koen; Torsello, Giovanni; Scheinert, Dierk; Maene, Lieven; Peeters, Patrick; Müller-Hülsbeck, Stefan; Sievert, Horst; Langhoff, Ralf; Bosiers, Michel; Setacci, Carlo

    2016-08-05

    The aim of this study was to evaluate the 30-day clinical outcome of treatment using the Roadsaver carotid stent in non-consecutive subjects at high risk for carotid endarterectomy requiring revascularisation. The CLEAR-ROAD study is a prospective, multinational, single-arm, physician-initiated study planned to include 100 patients in nine centres in Belgium, Italy and Germany. The primary endpoint was the 30-day rate of major adverse events (MAE), defined as the cumulative incidence of any death, stroke or myocardial infarction (MI). The use of embolic protection devices (EPDs) was not mandatory; 31.0% of the patients were symptomatic and in 58.0% of the patients EPDs were used. Technical success was achieved in all cases. The 30-day MAE rate was 2.1% (one patient experienced MI followed by death; another patient experienced a stroke within the first 30 days after procedure). While no statistical analysis could be performed, subgroup data suggested that there were no notable differences in the 30-day MAE rate between symptomatic and asymptomatic patients, or between EPD use. The 30-day clinical outcome of 100 patients treated with a dual layer micromesh carotid stent (Roadsaver) shows promising results. The Roadsaver stent is a safe and effective device for endovascular treatment of subjects at high risk for carotid endarterectomy.

  19. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  20. Lesion-Related Carotid Angioplasty and Stenting with Closed-Cell Design without Embolic Protection Devices in High-Risk Elderly Patients-Can This Concept Work Out? A Single Center Experience Focusing on Stent Design.

    Science.gov (United States)

    Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan

    2014-12-01

    To compare the performance differences of three carotid artery stents in high-risk elderly patients without embolic protection devices (EPDs) on the basis of stent design, procedure-related complications, conveniences in handling, in-stent restenosis, 30-day outcome, and long-term follow-up. A total of 101 symptomatic internal carotid stenoses of 94 patients were prospectively treated with stent-protected angioplasty to 94 patients. Three closed-cell stents, one of those being hybrid cell design, were chosen depending on vascular anatomy: curved vessel, lesion length > 1 cm: 64 Carotid Wallstent (Boston Scientific, Natick, MA); curved vessel, lesion length  1 cm: 16 Xact (Vascular Abbott, Santa Clara, CA). Comparisons of demographics, procedures, and outcomes were performed. The mean age of patients was 73.1 years (standard deviation [SD], ± 7.9; range, 58-87 years), 71% of the patients were older than 70 years and 20% were octogenarians. Male/female ratio was 3.1:1. About 13.9% (14/101) had contralateral internal carotid artery occlusion. Overall peri-interventional complication rate was 2.9% and 30-day mortality rate was 1%. During the long-term follow-up (34 months, range 1-59) no ipsilateral stroke was documented. Ten deaths (three after MI) were recognized. Two in-stent restenosis were detected (> 70% North American Symptomatic Carotid Endarterectomy Trial) during follow-up, one patient was detected with previous carotid endarterectomy. Especially, if individual anatomical variance is considered, lesion-related stent-protected carotid angioplasty with lesion-adapted closed-cell design is an effective, reliable, safe, and comprehensible treatment option in symptomatic patients. Even without EPDs, the rate of complications is low, when compared with symptomatic carotid artery stenosis described in the literature. In-stent restenosis seems to play no significant role in follow-up.

  1. Silent ischemia after neuroprotected percutaneous carotid stenting: a diffusion-weighted MRI study.

    Science.gov (United States)

    Piñero, P; González, A; Mayol, A; Martínez, E; González-Marcos, J R; Boza, F; Cayuela, A; Gil-Peralta, A

    2006-01-01

    To assess by diffusion-weighted MR imaging (DWI) the efficacy of cerebral protection devices in avoiding embolization and new ischemic lesions in patients with severe internal carotid artery (ICA) stenosis undergoing carotid artery stent placement (CAS). One hundred sixty-two CASs in the extracranial ICA were performed with the use of distal filters. Mean age of the patients was 68.5 years (range, 33-86) and 122 patients (75.3%) were symptomatic. MR imaging was performed in all patients during the 3-day period before CAS, and DWI was obtained within 24 hours after the procedure. Ninety-five patients (58.6%) were monitored by transcranial Doppler ultrasonography for microemboli detection in the territory of the middle cerebral artery (MCA), ipsilateral to the vessel being treated. Twenty-eight patients (17.3%) showed 58 new ischemic foci in DWI, and 13 patients (46.4%) had multiple foci. Location of new lesions was mainly in the vascular territory supplied by the treated vessel (19 patients; 67.9%), but also in the contralateral MCA (1 patient; 3.6%), and the posterior fossa (4 patients; 14.3%). A significant relationship (P neuroprotected CAS. Appearance of new ischemic lesions were only significantly related to the occurrence of TIA but not to the number of MES registered or other variables. Despite the encouraging results, the incidence of new ischemic lesions should promote research for safer techniques and devices.

  2. Plasma thrombin-cleaved osteopontin elevation after carotid artery stenting in symptomatic ischemic stroke patients

    International Nuclear Information System (INIS)

    Kurata, Mie; Okura, Takafumi; Kumon, Yoshiaki; Tagawa, Masahiko; Watanabe, Hideaki; Miyazaki, Tatsuhiko; Higaki, Jitsuo; Nose, Masato; Nakahara, Toshinori

    2012-01-01

    Atherothrombosis is the primary pathophysiology that underlies ischemic cerebral infarction. Osteopontin (OPN) is produced in atherosclerotic lesions and is cleaved by activated thrombin. We hypothesized that the rupture or damage of an unstable atherosclerotic plaque increases plasma levels of thrombin-cleaved OPN (trOPN). This study included 90 patients who received carotid angioplasty with stenting (CAS), 23 patients with essential hypertension (EHT) and 10 patients who were treated with carotid endarterectomy (CEA). The CAS patient group included 36 patients that had pre- and post-operative blood tests, diffusion-weighted imaging (DWI) using cerebral MRIs and estimated thrombus debris within the protection device. Immunohistochemistry of CEA specimens revealed that trOPN was detected around intra-plaque vessels. The highest tertile of plasma trOPN levels in CAS patients was higher than trOPN levels in EHT patients. Post-operative trOPN levels were significantly higher in symptomatic compared with asymptomatic patients (P=0.003). New ipsilateral DWI-positive patients revealed higher post-operative trOPN levels (P=0.003) and a higher grade of thrombi (P<0.001) than DWI-negative patients. TrOPN may be a novel biomarker that reflects the atherothrombotic status in ischemic stroke. (author)

  3. Lateral abdominal wall hematoma as a rare complication after carotid artery stenting: a case report

    Directory of Open Access Journals (Sweden)

    Satomi Jyunichiro

    2009-11-01

    Full Text Available Abstract Abdominal wall hematoma is a rare and life-threatening complication after carotid artery stenting (CAS, but it can occur when activated clotting time is prolonged. We report a right lateral abdominal wall hematoma caused by rupture of the superficial circumflex iliac artery after CAS in a 72-year-old man with severe stenosis of the origin of the right internal carotid artery. We performed CAS for the targeted lesion while activated clotting time exceeded 300 seconds. After 2 hours, he complained of right lateral abdominal pain. Abdominal computed tomography revealed an extensive hematoma in the right lateral abdominal wall. Activated clotting time was 180 seconds at this point. Seven hours later, he developed hypotension and hemoglobin level dropped to 11.3 g/dl. Subsequent computed tomography showed enlargement of the hematoma. Emergent selective angiography of the external iliac artery revealed active bleeding from the right superficial circumflex iliac artery. Transcatheter arterial embolization with Gelfoam and microcoils was performed successfully. With more CAS procedures being performed, it is important for endovascular surgeons and radiologists to consider the possibility of abdominal wall hematoma in this situation.

  4. Treatment of carotid siphon aneurysms by use of the Willis stent graft: an angiographic and histopathological study

    International Nuclear Information System (INIS)

    Zhu, Yue-Qi; Li, Ming-Hua; Xie, Jian; Tan, Hua-Qiao; Wang, Jian-Bo; Cheng, Ying-Sheng

    2010-01-01

    We designed a carotid siphon (CS) aneurysm model in dogs to test a new stent graft (the Willis covered stent) and compared tissue reaction over 12-month follow-up versus a comparison group with stents implanted in straight vessels. Twenty-four saccular sidewall aneurysms (group A) and 12 CS aneurysms (group B) were created surgically. A Willis stent graft was implanted in each aneurysm. Angiography was performed immediately and at 1-, 3-, 6- and 12-month post-implantation to investigate aneurysm isolation, endoleak, stent angulation, parent artery (PA) patency and restenosis. Light and scanning electron microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress. Immediate angiography demonstrated mild endoleak in two aneurysms and three stent angulations in group B. Follow-up at 12 months revealed resolved endoleaks, occlusion in one PA and mild stenosis in three in group B. In group A, occlusion occurred in one PA and mild stenosis in two. Light microscopy revealed new intima, and all aneurysm sacs were filled with thrombi. In group B, endothelial progress was complete at 12 months, and closely correlated with haemodynamic changes. Application of a Willis stent graft is a feasible method of treating CS aneurysms, and it exhibits a prolonged endothelial progress compared with that in straight vessels. (orig.)

  5. Endovascular treatment with a stent-graft for internal carotid artery laceration during trans sphenoidal surgery: a case report

    International Nuclear Information System (INIS)

    Choe, Eun Hwa; Ko, Ji Ho; Lee, Tae Hong; Rho, Myung Ho

    2008-01-01

    An internal carotid artery (ICA) tear during or after trans-sphenoidal surgery (TSS) is rare but may cause potentially lethal complications. A 23-year-old female patient visited our hospital for treatment of a Rathke's cleft cyst. The patient had massive hemorrhage during surgery and angiography performed after surgery showed laceration of the cavernous ICA. We successfully controlled the hemorrhage with emergency placement of an endovascular stent-graft

  6. Feasibility and efficacy of balloon-based neuroprotection during carotid artery stenting in a single-center setting.

    Science.gov (United States)

    Schlüter, Michael; Tübler, Thilo; Mathey, Detlef G; Schofer, Joachim

    2002-09-04

    We sought to prospectively assess the feasibility and in-hospital efficacy of the PercuSurge GuardWire temporary balloon-occlusive system for neuroprotection during carotid angioplasty and stenting (CAS).Carotid angioplasty and stenting harbors a risk of distal embolization. Cerebral protection devices are currently under clinical investigation.Ninety-six consecutive patients with carotid bifurcation disease underwent a total of 102 CAS procedures with the intention to use the GuardWire for neuroprotection. GuardWire deployment was achieved in 99 procedures performed in 93 patients (97%). Device failure (n = 3) and severe neurologic responses to balloon occlusion of the targeted carotid artery (n = 2) accounted for five additional procedures that were essentially concluded without neuroprotection, for a total of 94 procedures completed as intended in 88 patients (92% procedural feasibility rate). Carotid angioplasty and stenting was performed successfully in 94 patients (100 procedures). There were no in-hospital deaths; but three patients (3.1%) sustained strokes, and two patients experienced transient ischemic attacks, for a total periprocedural complication rate of 5.2%. One major stroke occurred with the GuardWire in place, whereas two minor strokes were observed in patients in whom the device could not be deployed. Thus, successful neuroprotected CAS without major neurologic events was achieved in 87 patients (91%). The GuardWire temporary balloon-occlusive system is feasible as an adjunct to CAS in the majority of patients. It is associated with a 3.1% rate of major periprocedural neurologic complications. Adverse neurologic reactions to balloon occlusion may prohibit effective use of the system in about 2% of patients.

  7. Carotid artery stenting in high surgical risk patients using the FiberNet embolic protection system: the EPIC trial results.

    Science.gov (United States)

    Myla, Subbarao; Bacharach, J Michael; Ansel, Gary M; Dippel, Eric J; McCormick, Daniel J; Popma, Jeffrey J

    2010-05-01

    The multicenter EPIC (FiberNet Embolic Protection System in Carotid Artery Stenting Trial) single-arm trial evaluated the 30-day outcomes of a new design concept for embolic protection during carotid artery stenting (CAS). Embolic protection filters available for use during CAS include fixed and over-the-wire systems that rely on embolic material capture within a "basket" structure. The FiberNet Embolic Protection System (EPS), which features a very low crossing profile, consists of a three-dimensional fiber-based filter distally mounted on a 0.014 inch guidewire with integrated aspiration during filter retrieval. The trial enrolled 237 patients from 26 centers. Demographics, clinical and lesion characteristics, as well as adverse events through a 30-day follow-up were recorded. The mean age of the patients was 74 years, 64% were male and 20% had symptomatic carotid artery disease. The combined major adverse event (MAE) rate at 30 days for all death, stroke, and myocardial infarction was 3.0%. There were three major strokes (two ischemic and one hemorrhagic) and two minor strokes (both ischemic) for a 2.1% 30-day stroke rate. The procedural technical success rate was 97.5% and macroscopic evidence of debris was reported in 90.9% of the procedures. The FiberNet EPS, used with commercially available stents, produced low stroke rates following CAS in high surgical risk patients presenting with carotid artery disease. The unique filter design including aspiration during retrieval may have contributed to the low 30-day stroke rate reported during CAS in patients considered at high risk for complications following carotid endarterectomy (CEA). Copyright 2010 Wiley-Liss, Inc.

  8. Quantitative analysis and predictors of embolic filter debris load during carotid artery stenting in asymptomatic patients.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Chincarini, Chiara; Fedrigo, Marny; Castellani, Chiara; Angelini, Annalisa; Grego, Franco; Antonello, Michele

    2018-03-01

    The objective of this study was to perform a quantitative analysis and to identify predictors of embolic filter debris (EFD) load during carotid artery stenting (CAS) in asymptomatic patients. All patients with asymptomatic carotid stenosis >70% undergoing CAS between 2008 and 2016 were included in a prospective database. A distal filter protection device was used in all patients. At the end of the procedure, the filter was fixed in formalin and then analyzed with a stereomicroscope. Morphometric analysis was performed with Image-Pro Plus software (Media Cybernetics, Rockville, Md). The total area of the filter membrane and the area covered by particulate material were quantified. The quantity of membrane occupied by debris was expressed as percentage of covered surface area. Anatomic and clinical variables were evaluated for their association with EFD load using multiple logistic regression. Among the 278 patients undergoing CAS, an open-cell stent was implanted in 211 patients (76%); 67 patients (24%) received a closed-cell stent. Overall technical success and clinical success were both 99%; no perioperative death was reported. Stroke rate was 1.8% (major, n = 1 [0.4%]; minor, n = 4 [1.4%]); transient ischemic attacks occurred in 5% of cases (n = 14). The quantitative analysis of the filter revealed that EFD was present in 74% of cases (n = 207). The mean EFD load was 10% of the filter surface (median, 1; range, 0-80); it was 31% in 22 (8%). Patients with any type of ischemic neurologic event after CAS (stroke and transient ischemic attack) had a significantly higher mean EFD load compared with uneventful cases (26.7% ± 19.0% vs 8.5% ± 13.5%; P 12.5% EFD load as the optimal cutoff for the association with clinically relevant perioperative ischemic events (sensitivity, 78%; specificity, 77%; area under the curve, 0.81). The multivariate analysis demonstrated that age >75 years (odds ratio [OR], 2.56; P = .003), pre-existing ipsilateral ischemic

  9. Short-Term Results of Carotid Endarterectomy and Stenting After the Introduction of Carotid Magnetic Resonance Imaging: A Single-Institution Retrospective Study.

    Science.gov (United States)

    Fukumitsu, Ryu; Yoshida, Kazumichi; Kurosaki, Yoshitaka; Torihashi, Koichi; Sadamasa, Nobutake; Koyanagi, Masaomi; Narumi, Osamu; Sato, Tsukasa; Chin, Masaki; Handa, Akira; Yamagata, Sen; Miyamoto, Susumu

    2017-05-01

    Although carotid artery stenting (CAS) has been gaining popularity as an alternative to carotid endarterectomy (CEA), perioperative stroke rate following contemporary CAS remains significantly higher than stroke rate after CEA. The purpose of this study was to assess perioperative (within 30 days) therapeutic results in patients with carotid stenosis (CS) after introduction of preoperative carotid magnetic resonance imaging plaque evaluation in a single center performing both CEA and CAS. Based on prospectively collected data for patients with CS who were scheduled for carotid revascularization, retrospective analysis was conducted of 295 consecutive patients with CS. An intervention was selected after consideration of periprocedural risks for both CEA and CAS. Concerning risk factors for CAS, results of magnetic resonance imaging plaque evaluation were emphasized with a view toward reducing embolic complications. CAS was performed in 114 patients, and CEA was performed in 181 patients. Comparing baseline characteristics of the 295 patients, age, T1 signal intensity of plaque, symptomatic CS, urgent intervention, and diabetes mellitus differed significantly between CAS and CEA groups. Among patients who underwent CAS, new hyperintense lesions on diffusion-weighted imaging were confirmed in 47 patients. New hyperintense lesions on diffusion-weighted imaging were recognized in 21.4% of patients who underwent CEA (n = 39), significantly less frequent than in patients who underwent CAS. The overall short-term outcome of CEA and CAS is acceptable. Preoperative carotid magnetic resonance imaging evaluation of plaque might contribute to low rates of ischemic complications in CAS. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. High-grade symptomatic and asymptomatic carotid stenosis in the very elderly. A challenge for proponents of carotid angioplasty and stenting

    Directory of Open Access Journals (Sweden)

    De Rossi Aldo

    2006-03-01

    Full Text Available Abstract Background Carotid angioplasty and stenting (CAS is often considered as the preferred treatment for severe carotid occlusive disease in patients labelled as "high risk", including those aged 80 or more. We analyzed 30-day stroke risk and death rates after carotid endarterectomy (CEA for severe symptomatic or asymptomatic carotid disease in patients aged 80 or more, by comparison with the outcome of CAS reported in the recently- published literature. Methods A retrospective review was conducted on a prospectively compiled computerized database of all primary CEAs performed by a single surgeon at our institution from 1990 to 2003. Descriptive demographic data, risk factors, surgical details, perioperative strokes and deaths, and other complications were recorded. Results In all, 1260 CEAs were performed in 1099 patients; 1145 were performed in 987 patients less than 80 years old, and 115 were performed in 112 patients aged 80 or more. There were 11 perioperative strokes in the 1145 procedures in the younger group, for a stroke rate of 0.8%, and no strokes in the 115 procedures in the older group. The death rates were 0% for the octogenarians and 0.3% for the younger group. Conclusion The conviction that older age means higher risk needs to be revised. Patients aged 80 or more can undergo CEA with no more perioperative risks than younger patients. Proponents of CAS should bear this in mind before recommending CAS as the best therapeutic option for such patients.

  11. Beneficial effects of prolonged blood pressure control after carotid artery stenting

    Directory of Open Access Journals (Sweden)

    Chang A

    2017-01-01

    Full Text Available Anna Chang,1 Huei-Fong Hung,2 Fang-I Hsieh,3 Wei-Hung Chen,1,4 Hsu-Ling Yeh,1,5 Jiann-Horng Yeh,1,6 Hou-Chang Chiu,1,6 Li-Ming Lien1,4 1Department of Neurology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, 2Department of Cardiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, 3School of Public Health, College of Public Health, Taipei Medical University, Taipei, 4School of Medicine, College of Medicine, Taipei Medical University, Taipei, 5Institute of Public Health, National Yang-Ming University, Taipei, 6School of Medicine, College of Medicine, Fu Jen Catholic University, Taipei, Taiwan Objectives: The main purpose of this study was to investigate whether carotid artery stenting (CAS plus medicine in patients with severe carotid artery stenosis provide a better long-term blood pressure (BP control compared to other medical treatments alone. The other aim was to explore the correlation between post-CAS hypotension within 6 h and long-term BP reductions after CAS. Materials and methods: Patients with severe carotid stenosis were recruited either in the CAS group or in the medication group. BPs and the number of classes of antihypertensive agents were recorded at baseline, 6, and 12 months. Extra BP information was collected at 6 h, 3 days, and 1 month after CAS. Univariate and multivariate linear regressions were performed to test the relationship of BP changes among CAS and medication groups after 6 and 12 months of follow-up. Univariate linear regressions were also used to determine the correlations between the mean or maximal systolic BP (SBP reductions at 6 h and 1 year post-CAS. Results: In total, 72 members in the CAS group and 82 members in the medication group were recruited. Compared with the medication group, patients in the CAS group had greater BP reductions at 6 and 12 months of follow-up after adjusting for confounding factors (13.56 mmHg at 6 months, P=0.0002; 16.98 mmHg at 12 months, P<0.0001. This study also shows significant

  12. CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kuya, Keita; Shinohara, Yuki; Fujii, Shinya; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago (Japan); Sakamoto, Makoto; Watanabe, Takashi [Tottori University, Division of Neurosurgery, Department of Brain and Neurosciences, Faculty of Medicine, Yonago (Japan); Iwata, Naoki; Kishimoto, Junichi [Tottori University, Division of Clinical Radiology Faculty of Medicine, Yonago (Japan); Kaminou, Toshio [Osaka Minami Medical Center, Department of Radiology, Osaka (Japan)

    2014-11-15

    Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS. (orig.)

  13. CT angiography after carotid artery stenting: assessment of the utility of adaptive statistical iterative reconstruction and model-based iterative reconstruction

    International Nuclear Information System (INIS)

    Kuya, Keita; Shinohara, Yuki; Fujii, Shinya; Ogawa, Toshihide; Sakamoto, Makoto; Watanabe, Takashi; Iwata, Naoki; Kishimoto, Junichi; Kaminou, Toshio

    2014-01-01

    Follow-up CT angiography (CTA) is routinely performed for post-procedure management after carotid artery stenting (CAS). However, the stent lumen tends to be underestimated because of stent artifacts on CTA reconstructed with the filtered back projection (FBP) technique. We assessed the utility of new iterative reconstruction techniques, such as adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR), for CTA after CAS in comparison with FBP. In a phantom study, we evaluated the differences among the three reconstruction techniques with regard to the relationship between the stent luminal diameter and the degree of underestimation of stent luminal diameter. In a clinical study, 34 patients who underwent follow-up CTA after CAS were included. We compared the stent luminal diameters among FBP, ASIR, and MBIR, and performed visual assessment of low attenuation area (LAA) in the stent lumen using a three-point scale. In the phantom study, stent luminal diameter was increasingly underestimated as luminal diameter became smaller in all CTA images. Stent luminal diameter was larger with MBIR than with the other reconstruction techniques. Similarly, in the clinical study, stent luminal diameter was larger with MBIR than with the other reconstruction techniques. LAA detectability scores of MBIR were greater than or equal to those of FBP and ASIR in all cases. MBIR improved the accuracy of assessment of stent luminal diameter and LAA detectability in the stent lumen when compared with FBP and ASIR. We conclude that MBIR is a useful reconstruction technique for CTA after CAS. (orig.)

  14. [Measurements of blood velocities using duplex sonography in carotid artery stents: analysis of reliability in an in-vitro model and computational fluid dynamics (CFD)].

    Science.gov (United States)

    Schönwald, U G; Jorczyk, U; Kipfmüller, B

    2011-01-01

    Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Transcranial Doppler monitoring during stenting of the carotid bifurcation: evaluation of two different distal protection devices in preventing embolization.

    Science.gov (United States)

    Rubartelli, Paolo; Brusa, Giulia; Arrigo, Alessandro; Abbadessa, Francesco; Giachero, Corinna; Vischi, Massimo; Ricca, Maria Maddalena; Ottonello, Gian Andrea

    2006-08-01

    To compare the efficacy of 2 emboli protection devices in preventing embolization during carotid artery stenting (CAS). The GuardWire distal occlusion system (n=19) and the distal FilterWire EX (n=12) were compared in 31 consecutive patients (24 men; mean age 71+/-10 years) monitored with transcranial Doppler for microembolic signals before, during, and after CAS. The choice of the protection device was based on availability and on the patency of the contralateral carotid artery. The baseline characteristics were similar in the patients treated under protection from either device. Placement and retrieval of the protection device, stenting, and postdilation were technically successful in all patients. Two patients suffered a transient ischemic attack shortly after the procedure; no other adverse cardiovascular events occurred at 30 days. Compared to the GuardWire, the use of the FilterWire was associated with more microembolic signals during stent deployment (77.4+/-33.5 versus 1.07+/-1.94, pprotection device (21.4+/-15.4 versus 10.9+/-8.3, p=0.051). Consequently, the total amount of microembolic signals during the procedure was higher when the filter device was employed (183.0+/-42.1 versus 31.7+/-12.0, p<0.0001). The distal occlusion device appears to be more effective than the filter in reducing distal embolization detected by transcranial Doppler monitoring.

  16. Clinical Comparison of Outcomes of Early versus Delayed Carotid Artery Stenting for Symptomatic Cerebral Watershed Infarction due to Stenosis of the Proximal Internal Carotid Artery

    Directory of Open Access Journals (Sweden)

    Huakun Liu

    2016-01-01

    Full Text Available The aim of this study was to compare the clinical outcomes of early versus delayed carotid artery stenting (CAS for symptomatic cerebral watershed infarction (sCWI patients due to stenosis of the proximal internal carotid artery. We retrospectively collected clinical data of those who underwent early or delayed CAS from March 2011 to April 2014. The time of early CAS and delayed CAS was within a week of symptom onset and after four weeks from symptom onset. Clinical data such as second stroke, the National Institutes of Health Stroke Scale (NHISS score, and modified Rankin Scale (mRS score and periprocedural complications were collected. The rate of second stroke in early CAS group is lower when compared to that of delayed CAS group. There was no significant difference regarding periprocedural complications in both groups. There was a significant difference regarding mean NHISS score 90 days after CAS in two groups. Early CAS group had a significant better good outcome (mRS score ≤ 2 than delayed CAS group. We suggest early CAS for sCWI due to severe proximal internal carotid artery stenosis as it provides lower rate of second stroke, comparable periprocedural complications, and better functional outcomes compared to that of delayed CAS.

  17. Delayed Development of Brain Abscesses Following Stent-Graft Placement in a Head and Neck Cancer Patient Presenting with Carotid Blowout Syndrome

    International Nuclear Information System (INIS)

    Oweis, Yaseen; Gemmete, Joseph J.; Chaudhary, Neeraj; Pandey, Aditya; Ansari, Sameer

    2011-01-01

    We describe the delayed development of intracranial abscesses following emergent treatment with a covered stent-graft for carotid blowout syndrome (CBS) in a patient with head and neck cancer. The patient presented with hemoptysis and frank arterial bleeding through the tracheostomy site. A self-expandable stent-graft was deployed across a small pseudoaneurysm arising from the right common carotid artery (RCCA) and resulted in immediate hemostasis. Three months later, the patient suffered a recurrent hemorrhage. CT of the neck demonstrated periluminal fluid around the caudal aspect of the stent-graft with intraluminal thrombus and a small pseudoaneurysm. Subsequently, the patient underwent a balloon test occlusion study and endovascular sacrifice of the RCCA and right internal carotid artery. MRI of the brain demonstrated at least four ring-enhancing lesions within the right cerebral hemisphere consistent with intracranial abscesses that resolved with broad-spectrum antibiotic coverage.

  18. Short-term outcome after stenting versus endarterectomy for symptomatic carotid stenosis: a preplanned meta-analysis of individual patient data.

    Science.gov (United States)

    Bonati, Leo H; Dobson, Joanna; Algra, Ale; Branchereau, Alain; Chatellier, Gilles; Fraedrich, Gustav; Mali, Willem P; Zeumer, Hermann; Brown, Martin M; Mas, Jean-Louis; Ringleb, Peter A

    2010-09-25

    Results from randomised controlled trials have shown a higher short-term risk of stroke associated with carotid stenting than with carotid endarterectomy for the treatment of symptomatic carotid stenosis. However, these trials were underpowered for investigation of whether carotid artery stenting might be a safe alternative to endarterectomy in specific patient subgroups. We therefore did a preplanned meta-analysis of individual patient data from three randomised controlled trials. Data from all 3433 patients with symptomatic carotid stenosis who were randomly assigned and analysed in the Endarterectomy versus Angioplasty in Patients with Symptomatic Severe Carotid Stenosis (EVA-3S) trial, the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) trial, and the International Carotid Stenting Study (ICSS) were pooled and analysed with fixed-effect binomial regression models adjusted for source trial. The primary outcome event was any stroke or death. The intention-to-treat (ITT) analysis included all patients and outcome events occurring between randomisation and 120 days thereafter. The per-protocol (PP) analysis was restricted to patients receiving the allocated treatment and events occurring within 30 days after treatment. In the first 120 days after randomisation (ITT analysis), any stroke or death occurred significantly more often in the carotid stenting group (153 [8·9%] of 1725) than in the carotid endarterectomy group (99 [5·8%] of 1708, risk ratio [RR] 1·53, [95% CI 1·20-1·95], p=0·0006; absolute risk difference 3·2 [1·4-4·9]). Of all subgroup variables assessed, only age significantly modified the treatment effect: in patients younger than 70 years (median age), the estimated 120-day risk of stroke or death was 50 (5·8%) of 869 patients in the carotid stenting group and 48 (5·7%) of 843 in the carotid endarterectomy group (RR 1·00 [0·68-1·47]); in patients 70 years or older, the estimated risk with carotid stenting was twice that

  19. Comparison of carotid endarterectomy and stenting in real world practice using a regional quality improvement registry

    Science.gov (United States)

    Nolan, Brian W.; De Martino, Randall R.; Goodney, Philip P.; Schanzer, Andres; Stone, David H.; Butzel, David; Kwolek, Christopher J.; Cronenwett, Jack L.

    2013-01-01

    Objective Carotid artery stenting (CAS) vs endarterectomy (CEA) remains controversial and has been the topic of recent randomized controlled trials. The purpose of this study was to compare the practice and outcomes of CAS and CEA in a real world setting. Methods This is a retrospective analysis of 7649 CEA and 430 CAS performed at 17 centers from 2003 to 2010 within the Vascular Study Group of New England (VSGNE). The primary outcome measures were (1) any in-hospital stroke or death and (2) any stroke, death, or myocardial infarction (MI). Patients undergoing CEA in conjunction with cardiac surgery were excluded. Multivariate logistic regression was performed to identify predictors of stroke or death in patients undergoing CAS. Results CEA was performed in 17 centers by 111 surgeons, while CAS was performed in 6 centers by 30 surgeons and 8 interventionalists. Patient characteristics varied by procedure. Patients undergoing CAS had a higher prevalence of coronary artery disease, congestive heart failure, diabetes, and prior ipsilateral CEA. Embolic protection was used in 97% of CAS. Shunts were used in 48% and patches in 86% of CEA. The overall in-hospital stroke or death rate was higher among patients undergoing CAS (2.3% vs 1.1%; P = .03). Overall stroke, death, or MI (2.8% CAS vs 2.1% CEA; P = .32) were not different. Asymptomatic patients had similar rates of stroke or death (CAS 0.73% vs CEA 0.89%; P = .78) and stroke, death, or MI (CAS 1.1% vs CEA 1.8%; P = .40). Symptomatic patients undergoing CAS had higher rates of stroke or death (5.1% vs 1.6%; P = .001), and stroke, death, or MI (5.8% vs 2.7%; P = .02). By multivariate analysis, major stroke (odds ratio, 4.5; 95% confidence interval [CI], 1.9–10.8), minor stroke (2.7; CI, 1.5–4.8), prior ipsilateral CEA (3.2, CI, 1.7–6.1), age >80 (2.1; CI, 1.3–3.4), hypertension (2.6; CI, 1.0–6.3), and a history of chronic obstructive pulmonary disease (1.6; CI, 1.0–2.4) were predictors of stroke or death

  20. Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade

    Energy Technology Data Exchange (ETDEWEB)

    Zorger, Niels; Finkenzeller, Thomas; Lenhart, Markus; Hamer, Okka; Paetzel, Christian; Borisch, Inghita; Toepel, Ingolf; Feuerbach, Stefan; Link, Johann [University of Regensburg Klinikum, Franz-Josef-Strauss-Allee 11, 93042, Regensburg (Germany)

    2004-04-01

    The aim of this study was evaluation of a closure device (Perclose, Menlo Park, Calif.) for closure of the femoral artery access site in patients undergoing aggressive anticoagulation and platelet blockade after carotid stenting. Fifty-five patients who received clopidogrel in addition to aspirin and heparin as medication for carotid stenting were included for suture of the femoral access site after using 7- or 8-F guide catheters. The technical success, the time for suture, the clotting parameters, and complications were examined. Follow-up investigations, including ultrasound and clinical examinations, were performed. The groin was checked for possible hematoma, pseudoaneurysm, arteriovenous fistula, and local infection. Technical success was obtained in 51 of 54 patients (94%) after a mean procedure time of 6 min (range 5-10 min). The suture device was not used in one patient (2%) for anatomical reasons and failed to obtain hemostasis in 3 of 54 (6%) patients. In 4 of 54 patients (7%) bleeding was observed at the punctured site 4-6 h after intervention which was treated by a compression bandage. The mean dedicated activated clotting time was 137 s (range 29-287 s) before intervention and 349 s (150-958 s) just before deploying the Perclose device. During follow-up after 2 days (range 2-6 days) and 6 months no further complications of the puncture site were observed except for two large groin hematomas. No major complications occurred. Closure of the femoral access site after carotid stenting using a Perclose closure device is safe and effective even in patients receiving an aggressive anticoagulation and antiplatelet therapy. (orig.)

  1. An Efficient Finite Element Framework to Assess Flexibility Performances of SMA Self-Expandable Carotid Artery Stents

    Directory of Open Access Journals (Sweden)

    Mauro Ferraro

    2015-07-01

    Full Text Available Computer-based simulations are nowadays widely exploited for the prediction of the mechanical behavior of different biomedical devices. In this aspect, structural finite element analyses (FEA are currently the preferred computational tool to evaluate the stent response under bending. This work aims at developing a computational framework based on linear and higher order FEA to evaluate the flexibility of self-expandable carotid artery stents. In particular, numerical simulations involving large deformations and inelastic shape memory alloy constitutive modeling are performed, and the results suggest that the employment of higher order FEA allows accurately representing the computational domain and getting a better approximation of the solution with a widely-reduced number of degrees of freedom with respect to linear FEA. Moreover, when buckling phenomena occur, higher order FEA presents a superior capability of reproducing the nonlinear local effects related to buckling phenomena.

  2. Usefulness of computed tomography angiography for the detection of high-risk aortas for carotid artery stenting

    International Nuclear Information System (INIS)

    Yamamoto, Hiromichi; Kuwayama, Naoya; Hayashi, Nakamasa; Kubo, Michiya; Endo, Shunro

    2011-01-01

    This study evaluated the usefulness of computed tomography (CT) angiography for the detection of high-risk aortas for carotid artery stenting (CAS). We investigated changes in the treatment method and modifications of endovascular techniques according to the information from CT angiography. CT angiography using three-dimensional and multi-planar reconstruction was performed in 43 consecutive patients with carotid artery stenoses intended to undergo CAS. Two neurosurgeons evaluated the images and estimated the risk and difficulties of CAS. CT angiography clearly depicted the entire aorta, the supra-aortic vessels, and the ilio-femoral arteries in all patients. Abnormal vascular findings were found in 17 patients. High-risk aortic lesions for CAS were detected in 5 patients, including thick aortic plaques with thrombi in 2. We changed the treatment strategy from CAS to carotid endarterectomy (CEA) in these 2 patients. CT angiograms proved very useful in evaluating the approach routes of CAS in 12 patients. One patient had dissecting aneurysm of the thoracic aorta and another had aberrant right vertebral artery. In these two, the treatment strategy was changed from CAS to CEA. The treatment method was changed in 4 patients in total. CT angiography is useful for the detection of high-risk aortas for CAS and for the evaluation of safe approaches to the carotid artery. (author)

  3. European Registry of Carotid Artery Stenting: results from a prospective registry of eight high volume EUROPEAN institutions.

    Science.gov (United States)

    Stabile, Eugenio; Garg, Pallav; Cremonesi, Alberto; Bosiers, Marc; Reimers, Bernhard; Setacci, Carlo; Cao, Piergiorgio; Schmidt, Andrej; Sievert, Horst; Peeters, Patrick; Nikas, Dimitry; Werner, Martin; de Donato, Gianmarco; Parlani, Giambattista; Castriota, Fausto; Hornung, Marius; Mauri, Laura; Rubino, Paolo

    2012-08-01

    Carotid endarterectomy (CEA) is the standard revascularization therapy to prevent stroke in patients with carotid artery disease. Carotid artery stenting (CAS) could be considered a potential alternative in patients at high surgical risk. Recent clinical trials have challenged this concept due a relatively high incidence of post-CAS adverse events, which occurred in low volume centers. The aim of this study was to evaluate the outcomes associated with neuroprotected CAS in selected high volume centers. From January 2007 to December 2007, 1,611 patients underwent neuroprotected CAS in eight European Centers. For each patients, clinical, procedural, and one month follow-up data from all patients have been collected. An independent clinical events committee adjudicated the events. Overall in hospital death was 0.06% (one patient), whereas in-hospital stroke was 0.49% (eight patients). Between hospital discharge and 30 days three additional patients died (0.18%) and 10 patients experienced a stroke (0.67%). Overall 30 days mortality was 0.24% (four patients) and stroke incidence 1.12% (18 patients). The 30 day stroke/death rate was 1.36%. CAS is a reasonable alternative to CEA to treat carotid artery atherosclerosis in well-experienced high volume centers. These data suggest that future prospective trials comparing CAS and CEA outcomes should include only centers highly experienced in both treatment modalities. Copyright © 2012 Wiley Periodicals, Inc.

  4. Epistaxis revealing the rupture of a carotid aneurysm of the cavernous sinus extending into the sphenoid: treatment using an uncovered stent and coils. Review of literature.

    Science.gov (United States)

    Lehmann, Pierre; Saliou, Guillaume; Page, Cyril; Balut, Antonia; Le Gars, Daniel; Vallée, Jean Noel

    2009-05-01

    True carotid aneurysms with sphenoid extension and revealed by epistaxis are rare. A review of the literature shows the mortality risk of this pathology and the different therapeutic options. A 41-year-old female presented with a cavernous carotid aneurysm with sphenoid extension revealed by massive epistaxis. We propose a combined treatment of the affected vessel using coils and an uncovered stent. The first stage to stop the hemorrhages and occlude the aneurysm using the coil and the second stage several days later after anticoagulation using the stent to prevent revascularization. This treatment has been shown to be effective in producing immediate hemostasis and stable long-term occlusion.

  5. Randomized comparison of distal and proximal cerebral protection during carotid artery stenting.

    Science.gov (United States)

    Cano, Manuel N; Kambara, Antônio M; de Cano, Silvia J F; Pezzi Portela, Luiz Antônio; Paes, Ângela Tavares; Costa, J Ribamar; Abizaid, Alexandre Antônio Cunha; Moreira, Samuel Martins; Sousa, Amanda G M R; Sousa, J Eduardo Moraes Rego

    2013-11-01

    This study sought to randomly compare cerebral protection with ANGIOGUARD (Cordis Corporation, Bridgewater, New Jersey) with Mo.Ma (Invatec/Medtronic Vascular Inc, Santa Rosa, California) during carotid artery stenting (CAS), using diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic cerebral lesions. The number, size, and location of lesions were analyzed. The choice of the type of cerebral protection during CAS is controversial. From July 2008 to July 2011, 60 patients undergoing CAS were randomized to ANGIOGUARD or Mo.Ma, distributed by chance, 30 patients for each group. All patients underwent DW-MRI before and after CAS. An independent neuroradiologist blinded to the cerebral protection used analyzed the images. Univariate and multivariate logistic models were fitted to analyze new ischemic lesions. Alternatively, a propensity score approach was used to reduce the bias due to differences between the groups. For the number of lesions, we used Poisson regression models. New ischemic lesions seen on DW-MRI were present in 63.3% of the ANGIOGUARD group versus 66.7% of the Mo.Ma cohort (p = 0.787). The number of ischemic cerebral lesions per patient, when present, was significantly lower in the Mo.Ma group (a median of 6 lesions per patient vs. a median of 10 in the ANGIOGUARD, p minor stroke during CAS (1.66%). New ischemic lesions seen on DW-MRI were present in both groups in >60%, but the number of lesions per patient was greater in the ANGIOGUARD group. No death or disabling stroke occurred during at least 1 year of follow-up in both cohorts. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Prediction of persistent hemodynamic depression after carotid angioplasty and stenting using artificial neural network model.

    Science.gov (United States)

    Jeon, Jin Pyeong; Kim, Chulho; Oh, Byoung-Doo; Kim, Sun Jeong; Kim, Yu-Seop

    2018-01-01

    To assess and compare predictive factors for persistent hemodynamic depression (PHD) after carotid artery angioplasty and stenting (CAS) using artificial neural network (ANN) and multiple logistic regression (MLR) or support vector machines (SVM) models. A retrospective data set of patients (n=76) who underwent CAS from 2007 to 2014 was used as input (training cohort) to a back-propagation ANN using TensorFlow platform. PHD was defined when systolic blood pressure was less than 90mmHg or heart rate was less 50 beats/min that lasted for more than one hour. The resulting ANN was prospectively tested in 33 patients (test cohort) and compared with MLR or SVM models according to accuracy and receiver operating characteristics (ROC) curve analysis. No significant difference in baseline characteristics between the training cohort and the test cohort was observed. PHD was observed in 21 (27.6%) patients in the training cohort and 10 (30.3%) patients in the test cohort. In the training cohort, the accuracy of ANN for the prediction of PHD was 98.7% and the area under the ROC curve (AUROC) was 0.961. In the test cohort, the number of correctly classified instances was 32 (97.0%) using the ANN model. In contrast, the accuracy rate of MLR or SVM model was both 75.8%. ANN (AUROC: 0.950; 95% CI [confidence interval]: 0.813-0.996) showed superior predictive performance compared to MLR model (AUROC: 0.796; 95% CI: 0.620-0.915, p<0.001) or SVM model (AUROC: 0.885; 95% CI: 0.725-0.969, p<0.001). The ANN model seems to have more powerful prediction capabilities than MLR or SVM model for persistent hemodynamic depression after CAS. External validation with a large cohort is needed to confirm our results. Copyright © 2017. Published by Elsevier B.V.

  7. Interventions to increase enrollment in a large multicenter phase 3 trial of carotid stenting vs. endarterectomy.

    Science.gov (United States)

    Longbottom, Mary E; Roberts, Jamie N; Tom, Meelee; Hughes, Susan E; Howard, Virginia J; Sheffet, Alice J; Meschia, James F; Brott, Thomas G

    2012-08-01

    Randomized clinical trials often encounter slow enrollment. Failing to meet sample size requirements has scientific, financial, and ethical implications. We report interventions used to accelerate recruitment in a large multicenter clinical trial that was not meeting prespecified enrollment commitments. The Carotid Revascularization Endarterectomy vs. Stenting Trial began randomization in December 2000. To accelerate enrollment, multiple recruitment tactics were initiated, which included expanding the number of sites, hiring a recruitment director (May 2003), broadening eligibility criteria (April 2005), branding with a study logo, Web site, and recruitment materials, increasing site visits by study leadership, sending e-mails to the site teams after every enrollment, distributing electronic newsletters, and implementing investigator and coordinator conferences. From December 2000 through May 2003, 14 sites became active (54 patients randomized), from June 2003 through April 2005, 44 sites were added (404 patients randomized), and from May 2005 through July 2008, 54 sites were added (2044 patients randomized). During these time intervals, the number of patients enrolled per site per year was 1·5, 3·6, and 5·6. For the single years 2004 to 2008, the mean monthly randomization rates per year were 19·7, 38·1, 56·4, 53·0, and 54·7 (annualized), respectively. Enrollment was highest after recruitment tactics were implemented: 677 patients in 2006, 636 in 2007, and 657 in 2008 (annualized). The prespecified sample size of 2502 patients, 47% asymptomatic, was accomplished on July 2008. Aggressive recruitment tactics and investment in a full-time recruitment director who can lead implementation may be effective in accelerating recruitment in multicenter trials. © 2012 The Authors. International Journal of Stroke © 2012 World Stroke Organization.

  8. Treatment of traumatic internal carotid artery pseudoaneurysms with willis covered stents: a midterm follow-up result

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Li Yongdong; Gu Binxian; Fang Chun; Tan Huaqiao; Wang Ju; Zhang Peilei

    2010-01-01

    Objective: To evaluate the efficacy and mid-term follow-up results of endovascular treatment with Willis covered stent for traumatic pseudoaneurysms located in the internal carotid artery (ICA). Methods: ICA angiography was performed in 38 patients with traumatic brain and neck injury. Of the 38 patients, 13 delayed traumatic pseudoaneurysms were found. All the pseudoaneurysms were treated with Willis covered stents. Follow-up angiography was performed at 1, 3, 6 and 12 months after the procedure, and the results were categorized as complete or incomplete occlusion. Clinical manifestations were graded as full recovery, improvement, unchanged and aggravation. Results: Willis covered stent placement was technically successful in all traumatic pseudoaneurysms. No procedure-related complications occurred. The initial angiographic results showed a complete occlusion in 9 patients, and an incomplete occlusion in 4. The angiographic follow-up within 3-12 months exhibited a complete occlusion in 12 patients and the parent arteries remained patency in all patients. The clinical follow-up observation demonstrated that full recovery was obtained in 11 patients, clinical improvement in one, and unchanged condition in one. No morbidity or mortality occurred. Conclusion: Willis covered stent implantation is a feasible and practical treatment for traumatic pseudoaneurysms located in the ICA. This technique can well preserve the parent artery with excellent therapeutic results. (authors)

  9. Angioplasty treatment and stent implant vs. surgical treatment in patients with stenosis of the cervical carotid artery

    International Nuclear Information System (INIS)

    Hamdan, Nabil; Castro, Pablo; Calderon, Luis I; Gomez, German; Estrada, Gilberto; Hurtado, Edgar; Echeverria, Rene

    2006-01-01

    Angioplasty with stent implant is a less invasive procedure than surgical intervention in the treatment of significant stenosis of the common cervical carotid artery (common and internal) (5). Currently the major published studies, in which angioplasty and surgical treatment are compared, show similar results in the major events, as cerebrovascular accidents and mortality, but a greater significant difference in the apparition of acute myocardial infarction, during surgical intervention (5,11). The objective of this study is to compare in both treatment methods the major and minor clinical events, like cerebrovascular accident, acute myocardial infarction, death, bradycardia, hypotension and encephalopathy during the intervention, the hospitalization and the follow-up year, as well as the re-intervention, the time of hospital stay and the complications of the surgical incision. Materials and methods: in this study of historical cohort, 46 patients with significant stenosis of the cervical carotid arteries, who were subjected to intervention from January 1st 2001 to December 31st 2003, were included. 21 patients were treated with angioplasty and stent implant and 25 with surgery (endarterectomy) Results: 1 (4.8%) major cerebrovascular accident occurred during angioplasty, whereas none occurred in the patients treated with surgery. 1 (4%) acute myocardial infarction occurred during intervention in the group of patients treated with surgery, and none in the patients treated with angioplasty. No deaths occurred in any of the groups during intervention, hospitalization and the follow-up year. After 8 months 1 (4%) patient treated with surgery was intervened again with angioplasty and stent implant. There were no statistically significant differences between both groups during hospitalization, and in the apparition of minor complications as bradycardia and hypotension. 2 (8%) complications related to the incision of the neck compromising cranial nerves, occurred in the

  10. Risk of Stroke or Death Is Associated With the Timing of Carotid Artery Stenting for Symptomatic Carotid Stenosis: A Secondary Data Analysis of the German Statutory Quality Assurance Database.

    Science.gov (United States)

    Tsantilas, Pavlos; Kuehnl, Andreas; Kallmayer, Michael; Knappich, Christoph; Schmid, Sofie; Breitkreuz, Thorben; Zimmermann, Alexander; Eckstein, Hans-Henning

    2018-03-27

    Subgroup analyses from randomized trials indicate that the time interval between the neurologic index event and carotid artery stenting is associated with periprocedural stroke and death rates in patients with symptomatic carotid stenosis. The aim of this article is to analyze whether this observation holds true under routine conditions in Germany. Secondary data analysis was done on 4717 elective carotid artery stenting procedures that were performed for symptomatic carotid stenosis. The patient cohort was divided into 4 groups according to the time interval between the index event and intervention (group I 0-2, II 3-7, III 8-14, and IV 15-180 days). Primary outcome was any in-hospital stroke or death. For risk-adjusted analyses, a multilevel multivariable regression model was used. The in-hospital stroke or death rate was 3.7% in total and 6.0%, 4.4%, 2.4%, and 3.0% in groups I, II, III, and IV, respectively. Adjusted analysis showed a decreased risk for any stroke or death in group III, a decreased risk for any major stroke or death in groups III and IV, and a decreased risk for any death in groups II and III compared to the reference group I. A short time interval between the neurologic index event and carotid artery stenting of up to 7 days is associated with an increased risk for stroke or death under routine conditions in Germany. Although results cannot prove causal relationships, carotid artery stenting may be accompanied by an increased risk of stroke or death during the early period after the index event. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  11. Association between age and risk of stroke or death from carotid endarterectomy and carotid stenting: a meta-analysis of pooled patient data from four randomised trials.

    Science.gov (United States)

    Howard, George; Roubin, Gary S; Jansen, Olav; Hendrikse, Jeroen; Halliday, Alison; Fraedrich, Gustav; Eckstein, Hans-Henning; Calvet, David; Bulbulia, Richard; Bonati, Leo H; Becquemin, Jean-Pierre; Algra, Ale; Brown, Martin M; Ringleb, Peter A; Brott, Thomas G; Mas, Jean-Louis

    2016-03-26

    Age was reported to be an effect-modifier in four randomised controlled trials comparing carotid artery stenting (CAS) and carotid endarterectomy (CEA), with better CEA outcomes than CAS outcomes noted in the more elderly patients. We aimed to describe the association of age with treatment differences in symptomatic patients and provide age-specific estimates of the risk of stroke and death within narrow (5 year) age groups. In this meta-analysis, we analysed individual patient-level data from four randomised controlled trials within the Carotid Stenosis Trialists' Collaboration (CSTC) involving patients with symptomatic carotid stenosis. We included only trials that randomly assigned patients to CAS or CEA and only patients with symptomatic stenosis. We assessed rates of stroke or death in 5-year age groups in the periprocedural period (between randomisation and 120 days) and ipsilateral stroke during long-term follow-up for patients assigned to CAS or CEA. We also assessed differences between CAS and CEA. All analyses were done on an intention-to-treat basis. Collectively, 4754 patients were randomly assigned to either CEA or CAS treatment in the four studies. 433 events occurred over a median follow-up of 2·7 years. For patients assigned to CAS, the periprocedural hazard ratio (HR) for stroke and death in patients aged 65-69 years compared with patients younger than 60 years was 2·16 (95% CI 1·13-4·13), with HRs of roughly 4·0 for patients aged 70 years or older. We noted no evidence of an increased periprocedural risk by age group in the CEA group (p=0·34). These changes underpinned a CAS-versus CEA periprocedural HR of 1·61 (95% CI 0·90-2·88) for patients aged 65-69 years and an HR of 2·09 (1·32-3·32) for patients aged 70-74 years. Age was not associated with the postprocedural stroke risk either within treatment group (p≥0·09 for CAS and 0·83 for CEA), or between treatment groups (p=0·84). In these RCTs, CEA was clearly superior to CAS in

  12. Comparison of enterprise and neuroform stent-assisted coil embolization of distal internal carotid artery aneurysms: Midterm results from a single-center experience

    International Nuclear Information System (INIS)

    Choi, Won Jin; Baik, Seung Kug; Yeom, Jeong A; Kim, Young Soo; Lee, Sang Weon

    2014-01-01

    To compare the mid-term follow-up angiographic findings in distal internal carotid artery (ICA) aneurysms treated by stent-assisted coil embolization using the Enterprise or Neuroform stent. We included 68 patients with 70 aneurysms: 31 cases with Enterprise and 39 cases with Neuroform. Inclusion criteria were 1) location of the stent within the distal ICA, including the carotid siphon; 2) follow-up angiogram after > 6 months, and 3) single use of the stent for 1 parent artery. The patients' mean age was 54.9 years (16 male and 52 female). Mean follow-up duration was 9.1 months. At follow-up, there were intraluminal filling defects of the parent artery in 19.4% of the Enterprise group and no filling defect in the Neuroform group. There was no significant in-stent stenosis in either group. Straightening of the parent artery was seen in 35.5% of the Enterprise group and 20.5% of the Neuroform group. Two Enterprise cases showed delayed migration. The Enterprise showed statistically significant intraluminal filling defects of the parent artery compared with the Neuroform. The rates of significant in-stent stenosis and straightening of the parent artery were not significantly different between the Enterprise and the Neuroform groups.

  13. The degradation and transport mechanism of a Mg-Nd-Zn-Zr stent in rabbit common carotid artery: A 20-month study.

    Science.gov (United States)

    Zhang, Jian; Li, Haiyan; Wang, Wu; Huang, Hua; Pei, Jia; Qu, Haiyun; Yuan, Guangyin; Li, Yongdong

    2018-03-15

    Mg-based stent is a promising candidate of the next generation fully degradable vascular stents. The latest progress includes the CE approval of the Magmaris ® WE43 based drug eluting stent. However, so far, the long term (more than 1 year implantation) in vivo degradation and the physiological effects caused by the degradation products were still unclear. In this study, a 20 month observation was carried out after the bare Mg-Nd-Zn-Zr (abbr. JDBM) stent prototype was implanted into the common carotid artery of New Zealand white rabbit in order to evaluate its safety, efficacy and especially degradation behavior. The degradation of the main second phase Mg 12 Nd was also studied. Results showed that the bare JDBM stent had good safety and efficacy with a complete re-endothelialization within 28 days. The JDBM stent struts were mostly replaced in situ by degradation products in 4 month. The important finding was that the volume and Ca concentration of the degradation products decreased in the long term, eliminating the clinicians' concern of possible vessel calcification. In addition, the alloying elements Mg and Zn in the stent could be safely metabolized as continuous enrichment in any of the main organs were not detected although Nd and Zr showed an abrupt increase in spleen and liver after 1 month implantation. Collectively, the long term in vivo results showed the rapid re-endothelialization of JDBM stent and the long term safety of the degradation products, indicating its great potential as the backbone of the fully degradable vascular stent. Mg-based stent is a promising candidate of the next generation fully degradable stents, especially after the recent market launch of one of its kind (Magmaris). However the fundamental question about the long term degradation and metabolic mechanism of Mg-based stent and its degradation products remain unanswered. We implanted our patented Mg-Nd-Zn-Zr bare stent into the common carotid artery of rabbits and

  14. Stent

    Science.gov (United States)

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Stent URL of this page: //medlineplus.gov/ency/article/002303.htm Stent To use the sharing features on this page, please enable JavaScript. A stent is a tiny tube placed into a hollow structure in your ...

  15. Demographic And Technical Risk Factors Of 30-Day Stroke, Myocardial Infarction, And/Or Death In Standard And High Risk Patients Who Underwent Carotid Angioplasty And Stenting

    Directory of Open Access Journals (Sweden)

    Samaneh Yousefi

    2017-02-01

    Full Text Available Background: Carotid angioplasty and stenting (CAS is an accepted treatment to prevent stroke in patients with carotid artery stenosis. The purpose of this study is to identify risk factors for major complications after carotid angioplasty and stenting. Methods and Material: This is a prospective study conducted at Shiraz University of Medical Sciences in southern Iran from March 2011 to June 2014. Consecutive patients undergoing carotid angioplasty and stenting were enrolled. Both standard risk and high risk patients for endarterectomy were enrolled. Demographic data, atherosclerotic risk factors, site of stenosis, degree of stenosis, and data regarding technical factors were recorded. 30-day stroke, myocardial infarction, and/or death were considered as the composite primary outcome of the study. Results:  two hundred and fifty one patients were recruited (mean age: 71.1+ 9.6 years, male: 65.3%.  One hundred and seventy eight (70.9% patients were symptomatic; 73 (29.1%, 129 (51.4%, 165 (65.7% and 62 (24.7% patients were diabetic, hyperlipidemic, hypertensive and smoker respectively. CAS performed for left ICA in 113 (45.4% patients. 14 (5.6% patients had Sequential bilateral stenting. Mean stenosis of operated ICA was 80.2 +13.8 %. Embolic protection device was used in 203 (96.2% patients. Predilation and post-dilation were performed in 39 (18.5% and 182 (86.3% patients respectively. Composite outcome was observed in 3.6% (3.2% stroke, 0% myocardial infarction and 1.2% death. Left sided lesions and presence of DM was significantly associated with poor short term outcome. (P value: 0.025 and 0.020, respectively Conclusion: There was a higher risk of short term major complications in diabetic patients and left carotid artery intervention.

  16. Overview of evidence on emergency carotid stenting in patients with acute ischemic stroke due to tandem occlusions: a systematic review and meta-analysis.

    Science.gov (United States)

    Coelho, Andreia; Lobo, Miguel; Gouveia, Ricardo; Silveira, Diogo; Campos, Jacinta; Augusto, Rita; Coelho, Nuno; Canedo, Alexandra

    2018-01-23

    Endovascular intracranial thrombectomy (IT) has established itself as the standard of care in treating large-vessel anterior circulation acute ischemic stroke (AIS). However, internal carotid artery (ICA) stenosis/occlusion hampers distal access and controversy about simultaneous emergency ICA stenting ensues. The purpose of this review was to evaluate the safety of emergency ICA stenting in combination with IT for AIS with tandem occlusions. To our knowledge this is the first meta-analysis to evaluate emergency ICA stenting in tandem occlusions, combining results from studies with a control group. A systematic review and meta-analysis was conducted according to the recommendations of the Preferred Reporting Items for Systematic reviews and Meta- Analyses (PRISMA) statement. A total of 649 potentially relevant articles were initially selected. After reviewing at title or abstract level, 87 articles were read in full and 23 were included. These studies recruited 1000 patients, 220 submitted to IT with no emergency ICA stenting and 780 to IT and emergency ICA stenting. Successful revascularization (Thrombolysis in cerebral infarction scale - TICI≥2b) was achieved in 48.6-100%. Good outcome (modified Rankin scale - mRS≤2) ranged from 18.2-100%. Symptomatic intracranial haemorrhage (sICH) ranged from 0-45.7% (overall n=168; 17.2%). Mortality at 90 days ranged from 0-45.4% (overall n=114; 11.7%). Time to recanalization was significantly longer in the stenting group with an overall mean difference of 1.76 (95% Confidence Interval: 1.59-1.93). In this meta-analysis time to recanalization was significantly longer in the emergency ICA stenting group. There was no benefit from emergency stenting in parameters such as successful revascularization (TICI≥2b), clinical outcome (mRS≤2) or 90-day mortality. Data on sICH were scarce. Emergency ICA stenting appears to increase time to revascularization and increase the risk of complications with no demonstrated clinical

  17. Thrombin Injection Failure with Subsequent Successful Stent-Graft Placement for the Treatment of an Extracranial Internal Carotid Pseudoaneurysm in a 5-Year-Old Child

    International Nuclear Information System (INIS)

    Garcia-Monaco, R. D.; Kohan, A. A.; Martinez-Corvalan, M. P.; Cacchiarelli, N.; Peralta, O.; Wahren, C. G.

    2012-01-01

    Internal carotid artery pseudoaneurysm is a rare life-threatening condition that may develop in different clinical situations. We report the case of an extracranial internal carotid artery pseudoaneurysm secondary to a throat infection in a pediatric patient that was initially treated with percutaneous thrombin injection under ultrasound guidance. However, recanalization occurred at 48 h, and definitive treatment was then performed by endovascular stent-graft placement. We briefly review the clinical characteristics of this uncommon clinical condition as well as the treatment options.

  18. New cerebral lesions at magnetic resonance imaging after carotid artery stenting versus endarterectomy: an updated meta-analysis.

    Directory of Open Access Journals (Sweden)

    Giuseppe Gargiulo

    Full Text Available Carotid endarterectomy (CEA or stenting (CAS are associated with a relatively low rate of clinical events, but diffusion-weighted imaging (DWI is increasingly being used to compare the incidence of new ischemic lesions. Therefore, we conducted an updated meta-analysis on the occurrence of post-procedural new DWI lesions after CAS versus CEA.MEDLINE, Cochrane, ISI Web of Science and SCOPUS databases were searched and 20 studies (2 randomized and 18 non-randomized with a total of 2104 procedures (CAS = 989; CEA = 1115 were included. The incidence of new DWI cerebral lesions was significantly greater after CAS than CEA (40.3% vs 12.2%; 20 studies; 2104 patients; odds ratio [OR] 5.17; 95% confidence interval [CI], 3.31-8.06; p<0.00001. Also peri-procedural stroke (17 studies; 1833 patients; OR 2.01; 95% CI, 1.14-3.55; p=0.02 and stroke or TIA (17 studies; 1833 patients; OR 2.40; 95% CI, 1.42-4.08; p=0.001 were significantly increased after CAS. This latter clinical advantage in the CEA group over CAS was tempered when CEA procedures were performed with shunting in all instead of selective shunting or when CAS was performed with only closed cell stents instead of both closed and open cell stents, however, no significant differences between subgroups emerged.CAS is associated with an increased incidence of post-procedural brain DWI lesions. This greater amount of ischemic burden may also reflect a higher rate of cerebral events after CAS. However, whether recent technical advances mainly for CAS could potentially reduce these ischemic events still remains to be evaluated.

  19. Patient characteristics and outcomes of carotid endarterectomy and carotid artery stenting: analysis of the German mandatory national quality assurance registry - 2003 to 2014.

    Science.gov (United States)

    Kallmayer, M A; Tsantilas, P; Knappich, C; Haller, B; Storck, M; Stadlbauer, T; Kühnl, A; Zimmermann, A; Eckstein, H H

    2015-12-01

    In Germany, every surgical or endovascular procedure on the extracranial carotid artery is documented in a mandatory quality assurance registry. The purpose of this study is to describe the patient characteristics, the indications for treatment, and the short-term outcomes as well as to analyse the corresponding trends from 2003 to 2014. Data on demographics, peri-procedural measures, and outcomes were extracted from the annual quality reports published by the Federal Agency for Quality Assurance and the Institute for Applied Quality Improvement and Research in Health Care. Data were available from 2003 to 2014 for carotid endarterectomy (CEA) and from 2012 to 2014 for carotid artery stenting (CAS). The primary outcome event of this study is any stroke or death until discharge from hospital. Temporal trends of categorical variables were statistically analysed using the Cochran-Armitage test for trend. Between 2003 and 2014, 309,405 CEAs and 18,047 CAS procedures were documented in the database; 68.1% of all patients were male. The mean age of patients treated with CEA increased from 68.9 years in 2003 to 70.9 years in 2014. The proportion of patients with ASA stages III to V increased from 65% to 71% in CEA, whereas it decreased from 44% to 41% in CAS patients. 53.1% of all CEAs were performed for asymptomatic patients (group A), 34.4% for symptomatic patients treated electively (group B), and 11.2% a in a collective group including other indications for CEA or CAS (such as recurrent stenosis, carotid aneurysms, emergency treatment due to stroke-in-evolution). The corresponding data for CAS are 49.3%, 26.1% and 26.3% respectively. In group B, the interval between the neurological index event and CEA decreased from 28 to 8 days (P<0.001). In patients treated with CAS, this interval was 9 days in 2012 (no further data available). On average, 67.1% and 48.2% of surgically treated patients as well as 77.8% and 69.8% of CAS patients were neurologically assessed before

  20. The use of virtual reality for training in carotid artery stenting: a construct validation study

    DEFF Research Database (Denmark)

    Berry, M.; Reznick, R.; Lystig, T.

    2008-01-01

    difference in video-gaming habits was demonstrated. Conclusion: With the exception of the metrics of performance time and fluoroscopic use, construct validity of the Procedicus-VIST carotid metrics were not confirmed. Virtual reality simulation as a training method was valued more by novices than...

  1. Duplex-assisted carotid artery stenting without administration of contrast medium for patients with chronic kidney disease or allergic reaction.

    Science.gov (United States)

    Mizowaki, Takashi; Fujita, Atsushi; Imahori, Taichiro; Uyama, Atsushi; Inoue, Satoshi; Kohta, Masaaki; Hamaguchi, Hirotoshi; Sasayama, Takashi; Hosoda, Kohkichi; Kohmura, Eiji

    2016-07-01

    We aimed to investigate the safety and feasibility of duplex-assisted carotid artery stenting (CAS) without administration of contrast medium for the prevention of adverse reactions. Fifteen patients (9 % of all CASs) with severe carotid stenosis (≥70 %) associated with chronic kidney disease (CKD) (stage ≥3) or allergy to contrast medium underwent duplex-assisted CAS without administration of contrast medium over 4 years. The procedural success rate and perioperative complication rates were compared between the duplex-assisted CAS (n = 15) and conventional CAS (n = 153) groups. The technical success rate was 100 % in both groups. Combined stroke or death rates during the post-procedural period did not differ significantly between the duplex-assisted CAS group (0/15, 0 %) and conventional CAS group (4/153, 2.6 %). None of the 14 patients with CKD in the duplex-assisted CAS group experienced further deterioration of renal function. The mean surface radiation dose of participants in the duplex-assisted CAS group (n = 13, 312 ± 131 mGy) was significantly lower than that of the conventional CAS group (n = 31, 1036 ± 571 mGy) (p duplex-assisted CAS group (156 ± 39.7 min) and the conventional CAS group (156 ± 37.4 min). Duplex-assisted CAS without administration of contrast medium could be an alternative option in selected patients deemed to be at high risk for renal failure from nephrotoxic contrast medium or who have an allergy to contrast medium.

  2. Distal protection filter device efficacy with carotid artery stenting: comparison between a distal protection filter and a distal protection balloon.

    Science.gov (United States)

    Iko, Minoru; Tsutsumi, Masanori; Aikawa, Hiroshi; Matsumoto, Yoshihisa; Go, Yoshinori; Nii, Kouhei; Abe, Gorou; Ye, Iwae; Nomoto, Yasuyuki; Kazekawa, Kiyoshi

    2013-01-01

    This retrospective study aimed to compare the effectiveness of the embolization prevention mechanism of two types of embolic protection device (EPD)-a distal protection balloon (DPB) and a distal protection filter (DPF). Subjects were 164 patients scheduled to undergo carotid artery stenting: a DPB was used in 82 cases (DPB group) from April 2007 until June 2010, and a DPF was used in 82 cases (DPF group) from July 2010 to July 2011. Rates of positive findings on postoperative diffusion-weighted imaging (DWI) and stroke incidence were compared. Positive postoperative DWI results were found in 34 cases in the DPB group (41.4 %), but in only 22 cases in the DPF group (26.8 %), and there was only a small significant difference within the DPF group. In the DPB group, there was one case of transient ischemic attack (TIA) (1.2 %) and four cases of brain infarction (2 minor strokes, 2 major strokes; 4.9 %), compared to the DFP group with one case of TIA (1.2 %) and no cases of minor or major strokes. In this study, significantly lower rates of occurrence of DWI ischemic lesions and intraoperative embolization were associated with use of the DPF compared to the DPB.

  3. Selective transcervical tubal recanalisation using DSA

    International Nuclear Information System (INIS)

    Kelekis, D.; Fezoulidis, I.; Petsas, T.; Tsapalira, A.; Kelekis, N.

    1991-01-01

    The results of selective transcervical tubal recanalisation by means of a catheter in 20 patients with tubal occlusions are reported and discussed. The advantages of tubal recanalisation under DSA are stressed. In 18 (90%) of the 20 patients treated, it was possible to recanalise at least one tube. Nine of these 18 women (50%) became pregnant during the period of observation, averaging 12 months. Selective transcervical recanalisation of obstructive tubes is a rapid, reliable, cheap and hardly invasive treatment of sterility, when compared with laparoscopy or laparotomy. In the majority of patients it makes surgery unnecessary. (orig.) [de

  4. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    International Nuclear Information System (INIS)

    San Millan Ruiz, Diego; Murphy, Kieran; Gailloud, Philippe

    2010-01-01

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  5. Subclinical ischemic events in patients undergoing carotid artery stent placement: comparison of proximal and distal protection techniques.

    Science.gov (United States)

    Aytac, Emrah; Gürkaş, Erdem; Akpinar, Cetin Kursad; Saleem, Muhammad A; Qureshi, Adnan I

    2017-10-01

    To determine the relative effectiveness of proximal and distal protection in prevention of cerebral ischemic events during carotid artery stent (CAS) placement using diffusion-weighted MRI (DW-MRI). We analyzed data from patients who had undergone DW-MRI before and within 24 hours of CAS for symptomatic internal carotid artery (ICA) stenosis (with last ischemic events within 3 months). The study was performed prospectively; patients were not randomized, and were treated either with a proximal balloon occlusion system (Mo.Ma; Invatec, Roncadelle, Italy) or filter-type distal protection device (Spider device; ev3, Plymouth, Minnesota, USA). Of the 45 patients (mean age±SD: 66.9±9.8 years; 73.3% were men) who underwent CAS, 19 had proximal protection and 26 distal protection. New ischemic lesions were detected in 26/45 patients on DW-MRI scans obtained within 24 hours after CAS. The proportion of patients with new lesions on DW-MRI at 24 hours was not different between the two groups (47.4% vs 65.4% for proximal and distal protection, respectively). The mean number of new ischemic lesions on post-CAS DW-MRI was non-significantly higher in patients who underwent CAS with distal protection (2.80±3.54 for proximal protection vs 4.96±5.11 for distal protection; p=0.12). The proportion of patients with new lesions >1 cm did not differ between the two groups (5.3% for proximal protection vs 11.5% for distal protection; p=0.62). There was no difference in the rates of ischemic stroke between patients who underwent CAS treatment using proximal and distal protection (5.3% vs 7.7%; p=1.000). We found a relatively high rate of new ischemic lesions in patients undergoing CAS with cerebral protection. There was no difference in the proportion of patients with new lesions between patients treated using distal protection and those treated using proximal protection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a

  6. A Case of Pseudoaneurysm of the Internal Carotid Artery Following Endoscopic Endonasal Pituitary Surgery: Endovascular Treatment with Flow-Diverting Stent Implantation

    Directory of Open Access Journals (Sweden)

    Ali Karadag

    2017-10-01

    Full Text Available Internal carotid artery (ICA pseudoaneurysm is a rare complication of endoscopic endonasal surgery occurring in 0.4–1.1% of cases. Pseudoaneurysms can subsequently result in other complications, such as subarachnoid hemorrhage, epistaxis, and caroticocavernous fistula with resultant death or permanent neurologic deficit. In this case, we illustrate endovascular treatment with a flow-diverting stent for an ICA pseudoaneurysm after endoscopic endonasal surgery for a pituitary adenoma in a 56-year-old male. Surgery was complicated by excessive intraoperative bleeding and emergent CT angiography confirmed an iatrogenic pseudoaneurysm on the anteromedial surface of the ICA. The pseudoaneurysm was treated endovascularly with flow-diverting stent implantation only. Follow-up CT angiography after three months demonstrated occlusion of the pseudoaneurysm.

  7. Serum Levels of IL-1β, IL-6, TGF-β, and MMP-9 in Patients Undergoing Carotid Artery Stenting and Regulation of MMP-9 in a New In Vitro Model of THP-1 Cells Activated by Stenting

    Directory of Open Access Journals (Sweden)

    Rongrong Zhang

    2015-01-01

    Full Text Available Inflammation plays an important role in the pathophysiological process after carotid artery stenting (CAS. Monocyte is a significant source of inflammatory cytokines in vascular remodeling. Telmisartan could reduce inflammation. In our study, we first found that, after CAS, the serum IL-1β, IL-6, TGF-β, and MMP-9 levels were significantly increased, but only MMP-9 level was elevated no less than 3 months. Second, we established a new in vitro model, where THP-1 monocytes were treated with the supernatants of human umbilical vein endothelial cells (HUVECs that were scratched by pipette tips, which mimics monocytes activated by mechanical injury of stenting. The treatment enhanced THP-1 cell adhesion, migration and invasion ability, and the phosphorylation of ERK1/2 and Elk-1 and MMP-9 expression were significantly increased. THP-1 cells pretreated with PD98095 (ERK1/2 inhibitor attenuated the phosphorylation of ERK1/2 and Elk-1 and upregulation of MMP-9, while pretreatment with telmisartan merely decreased the phosphorylation of Elk-1 and MMP-9 expression. These results suggested that IL-1β, IL-6, TGF-β, and MMP-9 participate in the pathophysiological process after CAS. Our new in vitro model mimics monocytes activated by stenting. MMP-9 expression could be regulated through ERK1/2/Elk-1 pathway, and the protective effects of telmisartan after stenting are partly attributed to its MMP-9 inhibition effects via suppression of Elk-1.

  8. Cerebrospinal Fluid Enhancement on Fluid Attenuated Inversion Recovery Images After Carotid Artery Stenting with Neuroprotective Balloon Occlusions: Hemodynamic Instability and Blood–Brain Barrier Disruption

    International Nuclear Information System (INIS)

    Ogami, Ryo; Nakahara, Toshinori; Hamasaki, Osamu; Araki, Hayato; Kurisu, Kaoru

    2011-01-01

    Purpose: A rare complication of carotid artery stenting (CAS), prolonged reversible neurological symptoms with delayed cerebrospinal fluid (CSF) space enhancement on fluid attenuated inversion recovery (FLAIR) images, is associated with blood–brain barrier (BBB) disruption. We prospectively identified patients who showed CSF space enhancement on FLAIR images. Methods: Nineteen patients—5 acute-phase and 14 scheduled—underwent 21 CAS procedures. Balloon catheters were navigated across stenoses, angioplasty was performed using a neuroprotective balloon, and stents were placed with after dilation under distal balloon protection. CSF space hyperintensity or obscuration on FLAIR after versus before CAS indicated CSF space enhancement. Correlations with clinical factors were examined. Results: CSF space was enhanced on FLAIR in 12 (57.1%) cases. Postprocedural CSF space enhancement was significantly related to age, stenosis rate, acute-stage procedure, and total occlusion time. All acute-stage CAS patients showed delayed enhancement. Only age was associated with delayed CSF space enhancement in scheduled CAS patients. Conclusions: Ischemic intolerance for severe carotid artery stenosis and temporary neuroprotective balloon occlusion, causing reperfusion injury, seem to be the main factors that underlie BBB disruption with delayed CSF space enhancement shortly after CAS, rather than sudden poststenting hemodynamic change. Our results suggest that factors related to hemodynamic instability or ischemic intolerance seem to be associated with post-CAS BBB vulnerability. Patients at risk for hemodynamic instability or with ischemic intolerance, which decrease BBB integrity, require careful management to prevent intracranial hemorrhagic and other post-CAS complications.

  9. Current Approaches for Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    Cengiz Köksal

    2010-12-01

    Full Text Available Permanent neurologic injuries and death following stroke, necessitates more vigorous treatment of carotid disease. Carotid stenting and carotid endarterectomy are treatment options in many centers besides medical treatment. Whether the patient is symptomatic or asymtomatic, indications and management strategies for treatment remain controversial. Despite the debate, carotid endarterectomy is still accepted to be the most efficientintervention to decrease risk of stroke due to carotid artery stenosis.

  10. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial.

    Science.gov (United States)

    Ansel, Gary M; Hopkins, L Nelson; Jaff, Michael R; Rubino, Paolo; Bacharach, J Michael; Scheinert, Dierk; Myla, Subbarao; Das, Tony; Cremonesi, Alberto

    2010-07-01

    The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30-day safety and effectiveness of the MO.MA Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion "endovascular clamping" system to achieve cerebral protection prior to crossing the carotid stenosis. This prospective registry enrolled 262 subjects, 37 roll-in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30-day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30-day MACCE rate was 2.7% [95% CI (1.0-5.8%)] with a 30-day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. The ARMOUR trial demonstrated that the MO.MA(R) Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date. (c) 2010 Wiley-Liss, Inc.

  11. Transcervical diverticulectomy for Killian–Jamieson diverticulum

    Directory of Open Access Journals (Sweden)

    Sze Li Siow

    2017-07-01

    Full Text Available Surgery for Killian–Jamieson diverticulum of the esophagus is scarcely reported in the literature owing to the rarity of this entity. This is a case report of such a diverticulum and a description of the transcervical diverticulectomy that we performed on a 49-year-old lady. The patient was investigated for symptoms of gastroesophageal reflux disease and was diagnosed with a left-sided Killian–Jamieson diverticulum.

  12. Risk reduction of brain infarction during carotid endarterectomy or stenting using sonolysis - Prospective randomized study pilot data

    Science.gov (United States)

    Kuliha, Martin; Školoudík, David; Martin Roubec, Martin; Herzig, Roman; Procházka, Václav; Jonszta, Tomáš; Krajča, Jan; Czerný, Dan; Hrbáč, Tomáš; Otáhal, David; Langová, Kateřina

    2012-11-01

    Sonolysis is a new therapeutic option for the acceleration of arterial recanalization. The aim of this study was to confirm risk reduction of brain infarction during endarterectomy (CEA) and stenting (CAS) of the internal carotid artery (ICA) using sonolysis with continuous transcranial Doppler (TCD) monitoring by diagnostic 2 MHz probe, additional interest was to assess impact of new brain ischemic lesions on cognitive functions. Methods: All consecutive patients 1/ with ICA stenosis >70%, 2/ indicated to CEA or CAS, 3/ with signed informed consent, were enrolled to the prospective study during 17 months. Patients were randomized into 2 groups: Group 1 with sonolysis during intervention and Group 2 without sonolysis. Neurological examination, assessment of cognitive functions and brain magnetic resonance imaging (MRI) were performed before and 24 hours after intervention in all patients. Occurrence of new brain infarctions (including infarctions >0.5 cm3), and the results of Mini-Mental State Examination, Clock Drawing and Verbal Fluency tests were statistically evaluated using T-test. Results: 97 patients were included into the study. Out of the 47 patients randomized to sonolysis group (Group 1) 25 underwent CEA (Group 1a) and 22 CAS (Group 1b). Out of the 50 patients randomized to control group (Group 2), 22 underwent CEA (Group 2a) and 28 CAS (Group 2b). New ischemic brain infarctions on follow up MRI were found in 14 (29.8%) patients in Group 1-4 (16.0%) in Group 1a and 10 (45.5%) in Group 1b. In Group 2, new ischemic brain infarctions were found in 18 (36.0%) patients-6 (27.3%) in Group 2a and 12 (42.9%) in Group 2b (p>0.05 in all cases). New ischemic brain infarctions >0.5 cm3 were found in 4 (8.5 %) patients in Group 1 and in 11 (22.0 %) patients in Group 2 (p= 0.017). No significant differences were found in cognitive tests results between subgroups (p>0.05 in all tests). Conclusion: Sonolysis seems to be effective in the prevention of large ischemic

  13. Cerebral Ischemia Detected with Diffusion-Weighted MR Imaging after Protected Carotid Artery Stenting: Comparison of Distal Balloon and Filter Device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk Jung; Jeon, Pyoung [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Roh, Hong Gee [Konkuk University Hospital, Seoul (Korea, Republic of)] (and others)

    2007-08-15

    The aim of this study was to examine the incidence of ischemia during protected carotid artery stenting (CAS) as well as to compare the protective efficacy of the balloon and filter devices on diffusion-weighted MR imaging (DWI). Seventy-one consecutive protected CAS procedures in 70 patients with a severe (> 70%) or symptomatic moderate (> 50%) carotid artery stenosis were examined. A balloon device (PercuSurge GuardWire) and a filter device (FilterWire EX/EZ, Emboshield) was used in 33 cases (CAS-B group) and 38 cases (CAS-F group) to prevent distal embolization, respectively. All the patients underwent DWI within seven days before and after the procedures. The number of new cerebral ischemic lesions on the post-procedural DWI were counted and divided into ipsilateral and contralateral lesions according to the relationship with the stenting side. New cerebral ischemic lesions were detected in 13 (39.4%) out of the 33 CAS-Bs and in 15 (39.5%) out of the 38 CAS-Fs. The mean number of total, ipsilateral and contralateral new cerebral ischemic lesion was 2.39, 1.67 and 0.73 in the CAS-B group and 2.11, 1.32 and 0.79 in the CAS-F group, respectively. No statistical differences were found between the two groups (p = 0.96, 0.74 and 0.65, respectively). The embolic complications encountered included two retinal infarctions and one hemiparesis in the CAS-B group (9.09%), and one retinal infarction, one hemiparesis and one ataxia in the CAS-F group (7.89%). There was a similar incidence of embolic complications in the two groups (p 1.00). The type of distal protection device used such as a balloon and filter does not affect the incidence of cerebral embolization after protected CAS.

  14. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting. Comparison of several anti-embolic protection devices

    International Nuclear Information System (INIS)

    Taha, M.M.; Maeda, Masayuki; Sakaida, Hiroshi

    2009-01-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm 3 vs. 86.9 mm 3 , respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm 3 ) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm 3 and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions. (author)

  15. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    Science.gov (United States)

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  16. Identification of critical areas of carotid stent navigation by measurement of resistive forces in vitro, using silicone phantoms

    International Nuclear Information System (INIS)

    Sengupta, A.; Kesavadas, T.; Baier, R.E.; Hoffmann, K.R.; Schafer, S.

    2007-01-01

    Manipulation of surgical tools in neuro-endovascular surgery presents problems that are unique to this procedure. Navigating tools through arterial complexities without appropriate visual or force feedback information often causes tool snagging, plaque dislocations and formation of thrombosis from the damage of the arterial wall by the tools. Identifying the critical areas in the vasculature during navigation of endovascular tools, will not only ensure safer surgical planning but also reduce risks of vessel damage. In the present research, resistive forces of stent navigation were measured in-vitro using silicone phantoms and clinically relevant surgical devices. The patterns of variation of the forces along the path of the stent movement were analyzed and mapped along the path of stent movement using a color code. It was observed that the forces changed along the length of the vessel, independent of the insertion length but based on the curvature of the vessel and the contact area of the device in the vessel lumen. (orig.)

  17. Transcervical heller myotomy using flexible endoscopy.

    Science.gov (United States)

    Spaun, Georg O; Dunst, Christy M; Arnold, Brittany N; Martinec, Danny V; Cassera, Maria A; Swanström, Lee L

    2010-12-01

    Esophageal achalasia is most commonly treated by laparoscopic myotomy. Transesophageal approaches using flexible endoscopy have recently been described. We hypothesized that using techniques and flexible instruments from our NOTES experience through a small cervical incision would be a safer and less traumatic route for esophageal myotomy. The purpose of this study was to evaluate the feasibility, safety, and success rate of using flexible endoscopes to perform anterior or posterior Heller myotomy via a transcervical approach. This animal (porcine) and human cadaver study was conducted at the Legacy Research and Technology Center. Mediastinal operations on ten live, anesthetized pigs and two human cadavers were performed using standard flexible endoscopes through a small incision at the supra-sternal notch. The esophagus was dissected to the phreno-esophageal junction using balloon dilatation in the peri-esophageal space followed by either anterior or posterior distal esophageal myotomy. Success rate was recorded of esophageal dissection to the diaphragm and proximal stomach, anterior and posterior myotomy, perforation, and complication rates. Dissection of the esophagus to the diaphragm and performing esophageal myotomy was achieved in 100% of attempts. Posterior Heller myotomy was always extendable onto the gastric wall, while anterior gastric extension of the myotomy was found to be more difficult (4/4 and 2/8, respectively; P = 0.061). Heller myotomy through a small cervical incision using flexible endoscopes is feasible. A complete Heller myotomy was performed with a higher success rate posteriorly possibly due to less anatomic interference.

  18. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    International Nuclear Information System (INIS)

    D’Ercole, Loredana; Quaretti, Pietro; Cionfoli, Nicola; Klersy, Catherine; Bocchiola, Milena; Rodolico, Giuseppe; Azzaretti, Andrea; Lisciandro, Francesco; Cascella, Tommaso; Zappoli Thyrion, Federico

    2013-01-01

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 ± 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 ± 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 ± 0.42 Gy) were FR ) were 269 Gy cm 2 , 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1–102.7, p FR overexposures (OR 10.8, 95 % CI 1.1–109.5, p FR overexposure (OR 2.8, 95 % CI 1.1–7.4, p = 0.040). At multivariable analysis, stenosis ≥ 90 % (OR 2.8, 95 % CI 1.1–7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1–109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  19. Análise morfométrica da carótida de suínos submetidos a angioplastia com ou sem implante de stent de cromo-cobalto Morphometric analysis of swine carotid artery angioplasty with or without cobalt-chromium stent implantation

    Directory of Open Access Journals (Sweden)

    João Luiz de Lara Elesbão

    2010-06-01

    Full Text Available Contexto: A hiperplasia intimal é a reação tardia mais comum decorrente da angioplastia. O uso de stents de cromo-cobalto é bem estudado na circulação coronariana, porém não há muitos estudos que abordem o uso desses stents nas circulações carotídea e periférica. Objetivo: Analisar mediante morfometria a reação intimal presente na artéria carótida de suínos submetidos a angioplastia isoladamente e a angioplastia seguida de implante de stent de cromo-cobalto. Materiais e métodos: Em oito suínos, foi realizada angioplastia da artéria carótida comum direita e angioplastia seguida de implante de um stent de cromo-cobalto na artéria carótida comum esquerda. Após 4 semanas, os animais foram submetidos a eutanásia para a retirada de amostras de tecido arterial e preparo de lâminas histológicas. As imagens das lâminas foram digitalizadas e analisadas por programa de morfometria digital. A análise estatística foi realizada através da média e desvio padrão das áreas em cada grupo, utilizando-se o Teste t de Student. O valor de p Background: Intimal hyperplasia is the most common delayed response to angioplasty. The use of cobalt-chromium stents is well studied in the coronary circulation; however, there are few studies on their use in the carotid and peripheral circulation. Objective: To analyze the intimal reaction in a swine carotid artery undergoing simple angioplasty and angioplasty followed by implantation of cobalt-chromium stent. Materials and methods: We carried out angioplasty in the right common carotid artery and angioplasty with cobalt-chromium stent in the left common carotid artery in eight swine. Four weeks later, all animals were sacrificed for arterial tissue sampling and preparation of histological slides. Slide images were scanned and analyzed using a digital morphometry program. Statistical analysis was performed by mean values and standard deviations of the areas in each group, using the Student's t

  20. Transcervical embryo recovery in Saanen goats | Lima-Verde ...

    African Journals Online (AJOL)

    In order to study the embryo recovery rate using the transcervical technique in Saanen goats raised in the tropics, 20 donors were submitted to an oestrus synchronisation treatment using intravaginal progestagen sponges for 11 days. On the ninth day of treatment, goats received intramuscular injections of 50 µg ...

  1. Temporary stenting and retrieval of the self-expandable, intracranial stent in acute middle cerebral artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Sang Hyun; Chung, Tae-Sub [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea); Lee, Kyung-Yul [Yonsei University College of Medicine, Department of Neurology, Gangnam Severance Hospital, Seoul (Korea); Hong, Chang Ki; Kim, Chang-Hyun [Yonsei University College of Medicine, Department of Neurosurgery, Gangnam Severance Hospital, Seoul (Korea); Kim, Byung Moon; Kim, Dong Ik [Yonsei University College of Medicine, Department of Radiology, Seoul (Korea)

    2009-08-15

    We describe our experience in which a retrievable Enterprise stent was used as a temporary recanalization and embolectomy device in an acute middle cerebral artery (MCA) occlusion after urgent stenting for ipsilateral carotid artery stenosis. (orig.)

  2. Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

    Energy Technology Data Exchange (ETDEWEB)

    D' Ercole, Loredana, E-mail: l.dercole@smatteo.pv.it [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Quaretti, Pietro; Cionfoli, Nicola [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Klersy, Catherine [Fondazione IRCCS Policlinico San Matteo, Biometry and Clinical Epidemiology Service, Research Department, (Italy); Bocchiola, Milena [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Rodolico, Giuseppe; Azzaretti, Andrea [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy); Lisciandro, Francesco [Fondazione IRCCS Policlinico San Matteo, Department of Medical Physics (Italy); Cascella, Tommaso; Zappoli Thyrion, Federico [Fondazione IRCCS Policlinico San Matteo, Department of Radiology (Italy)

    2013-04-15

    To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

  3. Useful technique for submucous myomectomy under direct transcervical resectoscope observation

    Directory of Open Access Journals (Sweden)

    Tatsuji Hoshino

    2017-08-01

    Full Text Available The transcervical resectoscope (TCR is used for resecting a submucous myoma (SMM. Safe grasping of an SMM with forceps and its complete resection under transabdominal ultrasound (TAUS guidance is not always easy. SMMs are slippery, making them difficult to grasp. The SMM moves right to left and anterior to posterior when the surgeon tries to grasp it with placental forceps. Surgeons could use small Martin forceps (65% smaller to grasp SMMs safely and tightly under direct TCR (transcervical resectoscope observation. We present a case in which this operative procedure was used to remove an SMM with Figure and Video. The benefits of this procedure are enormous and could be immeasurably important to hysteroscopists and gynecologists.

  4. Common carotid artery disease in Takayasu's arteritis

    International Nuclear Information System (INIS)

    Hamdan, Nabil; Calderon, Luis I; Castro, Pablo and others

    2004-01-01

    Takayasu's arteritis is a disease of unknown etiology with main involvement of the common carotid 5 artery and its branches. we report the case of a 69 years old female patient with Tokays arteritis with 2 bilateral involvements of the common carotid arteries, treated with percutaneous angioplasty and Stent implantation

  5. Application of willis covered stent in the treatment of aneurysms located in the cisternal segment of the internal carotid artery: a pilot comparative study with long-term follow-up results

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Fang Chun; Wang Wu; Zhang Peilei; Cheng Yingsheng; Tan Huaqiao; Wang Jianbo

    2010-01-01

    Objective: Complicated aneurysms located in the cisternal segment of the internal carotid artery(ICA-CSA) present unique therapeutic difficulties. This study is to discuss the feasibility of the Willis stent-graft in treating complicated ICA-CSA by comparing its effect with that of coiling therapy. Methods: Willis covered stents were employed in 19 complicated ICA-CSAs (group A), while coils were used in 17 complicated ICA-CSAs (group B). Follow-up angiography was performed to investigate aneurysm recurrence, endoleak and parent artery (PA) stenosis. Kaplan-Meier curves were constructed to compare the recurrence-free and PA stenosis-free rate in both groups. Results: Total exclusion was immediately achieved in 13 ICA-CSAs and minor endoleaks presented in 5 cases in group A. Total or near-total occlusion was achieved in 7 ICA-CSAs, subtotal occlusion in 8 and partial occlusion in 2 cases in group B after coiling. Acute thrombosis occurred in 1 patient in either group and re-hemorrhage happened in 1 patient after coiling. Follow-up angiography in group A revealed that 16 ICA-CSAs were completely isolated, with two parent arteries showing mild in-stent stenosis. Eighteen months after the procedure, Kaplan-Meier analysis showed that the recurrence-free rate was 93.3% and 50%, while the stenosis-free rate of parent artery was 87.5% and 100% in group A and in Group B, respectively. In group A and group Bthe clinical neurological symptoms were fully recovered in 9 and 9, obviously improved in 3 and 5, unchanged in 2 and 2, and aggravated in one and 0 patients, respectively. Conclusion: The implantation of Willis stent-graft is a feasible endovascular therapy for complicated ICA-CSAs. When the parent artery is very tortuous or when the risk that a main collateral branch may be wrongly covered and occluded is present, the implantation of Willis covered stent can not be taken as the treatment of first choice. (authors)

  6. Carotid artery and lower cranial nerve exposure with increasing surgical complexity to the parapharyngeal space.

    Science.gov (United States)

    Lemos-Rodriguez, Ana M; Sreenath, Satyan B; Rawal, Rounak B; Overton, Lewis J; Farzal, Zainab; Zanation, Adam M

    2017-03-01

    To investigate the extent of carotid artery exposure attained, including the identification of the external carotid branches and lower cranial nerves in five sequential external approaches to the parapharyngeal space, and to provide an anatomical algorithm. Anatomical study. Six latex-injected adult cadaver heads were dissected in five consecutive approaches: transcervical approach with submandibular gland removal, posterior extension of the transcervical approach, transcervical approach with parotidectomy, parotidectomy with lateral mandibulotomy, and parotidectomy with mandibulectomy. The degree of carotid artery exposure attained, external carotid branches, and lower cranial nerves visualized was documented. The transcervical approach exposed 1.5 cm (Standard Deviation (SD) 0.5) of internal carotid artery (ICA) and 1.25 cm (SD 0.25) of external carotid artery (ECA). The superior thyroid and facial arteries and cranial nerve XII and XI were identified. The posterior extension exposed 2.9 cm (SD 0.7) of ICA and 2.7 cm (SD 1.0) of ECA. Occipital and ascending pharyngeal arteries were visualized. The transparotid approach exposed 4.0 cm (SD 1.1) of ICA and 3.98 cm (SD 1.8) of ECA. Lateral mandibulotomy exposed the internal maxillary artery, cranial nerve X, the sympathetic trunk, and 4.6 cm (SD 2.4) of ICA. Mandibulectomy allowed for complete ECA exposure, cranial nerve IX, lingual nerve, and 6.9 cm (SD 1.3) of ICA. Approaches for the parapharyngeal space must be based on anatomic and biological patient factors. This study provides a guide for the skull base surgeon for an extended approach based on the desired anatomic exposure. N/A. Laryngoscope, 127:585-591, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Flow diversion in the treatment of carotid injury and carotid-cavernous fistula after transsphenoidal surgery

    Science.gov (United States)

    Lum, Cheemum; Ahmed, Muhammad E; Glikstein, Rafael; dos Santos, Marlise P; Lesiuk, Howard; Labib, Mohamed; Kassam, Amin B

    2015-01-01

    We describe a case of iatrogenic carotid injury with secondary carotid-cavernous fistula (CCF) treated with a silk flow diverter stent placed within the injured internal carotid artery and coils placed within the cavernous sinus. Flow diverters may offer a simple and potentially safe vessel-sparing option in this rare complication of transsphenoidal surgery. The management options are discussed and the relevant literature is reviewed. PMID:26015526

  8. Evaluation of changes in the parameters of brain tissue perfusion in multi-slice computed tomography in patients after carotid artery stenting

    NARCIS (Netherlands)

    Szarmach, Arkadiusz; Halena, Grzegorz; Buczny, Jacek; Studniarek, Michał; Markiet, Karolina; Szurowska, Edyta; Retkowski, Mariusz; Piskunowicz, Maciej

    BACKGROUND: CT perfusion of the brain allows functional evaluation of cerebral blood flow. Patients with chronic internal carotid artery (ICA) stenosis may suffer from malperfusion. Improvement of cerebral blood flow and remission of neurological symptoms indicate the effectiveness of treatment of

  9. Intrapartum transcervical amnioinfusion for meconium-stained amniotic fluid.

    Science.gov (United States)

    Das, A K; Jana, N; Dasgupta, S; Samanta, B

    2007-06-01

    To assess the rates of cesarean deliveries and perinatal outcome following intrapartum transcervical amnioinfusion in women with meconium-stained amniotic fluid (MSAF) in a setting with no electronic fetal monitoring or specialized neonatal care. In this prospective comparative study with 150 women who were in labor and had MSAF, 50 of the women received a transcervical amnioinfusion and the remaining 100 women received standard care. The inclusion criteria were a pregnancy of at least 37 weeks' duration, a single live fetus in cephalic presentation, no major medical or obstetric complications, and no known fetal malformation. The amnioinfusion was performed with 1000 mL of normal saline solution through a red rubber catheter. Amnioinfusion was associated with a significant decrease in the incidence of low Apgar score (amnioinfusion than in the control group (24% vs. 48%; RR, 0.5; 95% CI, 0.29-0.85). There were no major complications related to amnioinfusion. Intrapartum amnioinfusion for MSAF is a simple, safe, effective, and inexpensive procedure feasible in settings where intrapartum monitoring is limited. It is associated with improved perinatal outcome and could lower cesarean delivery rates in low-resource countries.

  10. Stroke prevention-surgical and interventional approaches to carotid stenosis

    Directory of Open Access Journals (Sweden)

    Kumar Rajamani

    2013-01-01

    Full Text Available Extra cranial carotid artery stenosis is an important cause of stroke, which often needs treatment with carotid revascularization. To prevent stroke recurrence, carotid endarterectomy (CEA has been well-established for several decades for symptomatic high and moderate grade stenosis. Carotid stenting is a less invasive alternative to CEA and several recent trials have compared the efficacy of the 2 procedures in patients with carotid stenosis. Carotid artery stenting has emerged as a potential mode of therapy for high surgical risk patients with symptomatic high-grade stenosis. This review focuses on the current data available that will enable the clinician to decide optimal treatment strategies for patients with carotid stenosis.

  11. Transcervical intrapartum amnioinfusion for preterm premature rupture of the membranes.

    Science.gov (United States)

    Puertas, Alberto; Tirado, Pilar; Pérez, Isabel; López, María S; Montoya, Francisco; Cañizares, José M; Miranda, José A

    2007-03-01

    To investigate the effect of transcervical amnioinfusion on the management of labour and neonatal outcomes in preterm premature rupture of the membranes. This clinical trial included 86 patients with premature rupture of the membranes between weeks 27 and 35 of gestation. Patients were randomly assigned to receive amnioinfusion via a two-way catheter or to the control group. Clinical management was otherwise the same in both groups. Amnioinfusion decreased the frequency of variable decelerations in fetal heart rate (27.9% versus 53.5%, pamnioinfusion for preterm premature rupture of the membranes reduced the number of interventions needed because of nonreassuring fetal status, and improved neonatal gasometric values without increasing maternal or fetal morbidity.

  12. Laparoscopic supracervical hysterectomy with transcervical morcellation: our experience.

    Science.gov (United States)

    Graziano, Angela; Lo Monte, Giuseppe; Hanni, Herbert; Brugger, Johann Georg; Engl, Bruno; Marci, Roberto

    2015-02-01

    To present our experience with laparoscopic supracervical hysterectomy with transcervical morcellation (LSH-TM). A retrospective observational study (Canadian Task Force Classification III). Gynecologic Department at Brunico Hospital, Brunico, Italy. Three hundred sixty-five patients affected by gynecologic benign diseases who underwent LSH-TM. A minimally invasive surgical technique for supracervical hysterectomy that involves extraction of the morcellated uterus through the cervical canal. We performed LSH-TM successfully in 365 patients; the mean (standard deviation) operating time was 72.24 (23.21) minutes. We registered no intraoperative complications. The main postoperative complications resulted in 2 cases of second-look laparoscopy because of internal bleeding, 5 cases of asymptomatic hematoma around the cervical stump, and 7 cases of pelvic pain. Our experience shows that LSH-TM is a safe and easy to perform technique and that it ensures minimal blood loss. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  13. The role of transcervical thymectomy in patients with hyperparathyroidism.

    Science.gov (United States)

    Welch, Kellen; McHenry, Christopher R

    2012-03-01

    The most common location for supernumerary or ectopic parathyroid glands is the thymus. A review of patients who underwent parathyroidectomy for hyperparathyroidism from 1990 to 2010 was completed to determine indications for thymectomy, the yield of parathyroid tissue, and outcome of therapy. Seventy of 379 patients with hyperparathyroidism underwent parathyroidectomy and transcervical thymectomy. Intrathymic parathyroid tissue was present in 23 (33%) patients, including supernumerary glands in 8 patients (11%). Indications for thymectomy were renal hyperparathyroidism in 35 patients (50%) and primary hyperparathyroidism with a missing inferior gland in 20 patients (29%), an ectopic adenoma in 9 patients (13%), hyperplasia in 5 patients (7%), and carcinoma in 1 patient (1%). Cure rates were similar (96% and 98%; P = not significant) and only transient hypocalcemia was higher (51% vs 24%, P hyperparathyroidism. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  15. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  16. Systematic preoperative coronary angiography and stenting improves postoperative results of carotid endarterectomy in patients with asymptomatic coronary artery disease: a randomised controlled trial.

    Science.gov (United States)

    Illuminati, G; Ricco, J-B; Greco, C; Mangieri, E; Calio', F; Ceccanei, G; Pacilè, M A; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Mazzesi, G; Miraldi, F; Tritapepe, L

    2010-02-01

    To evaluate the usefulness of systematic coronary angiography followed, if needed, by coronary artery angioplasty (percutaneous coronary intervention (PCI)) on the incidence of cardiac ischaemic events after carotid endarterectomy (CEA) in patients without evidence of coronary artery disease (CAD). From January 2005 to December 2008, 426 patients, candidates for CEA, with no history of CAD and with normal cardiac ultrasound and electrocardiography (ECG), were randomised into two groups. In group A (n=216) all the patients had coronary angiography performed before CEA. In group B, all the patients had CEA without previous coronary angiography. In group A, 66 patients presenting significant coronary artery lesions at angiography received PCI before CEA. They subsequently underwent surgery under aspirin (100 mg day(-1)) and clopidogrel (75 mg day(-1)). CEA was performed within a median delay of 4 days after PCI (range: 1-8 days). Risk factors, indications for CEA and surgical techniques were comparable in both groups (p>0.05). The primary combined endpoint of the study was the incidence of postoperative myocardial ischaemic events combined with the incidence of complications of coronary angiography. Secondary endpoints were death and stroke rates after CEA and incidence of cervical haematoma. Postoperative mortality was 0% in group A and 0.9% in group B (p=0.24). One postoperative stroke (0.5%) occurred in group A, and two (0.9%) in group B (p=0.62). No postoperative myocardial event was observed in group A, whereas nine ischaemic events were observed in group B, including one fatal myocardial infarction (p=0.01). Binary logistic regression analysis demonstrated that preoperative coronary angiography was the only independent variable that predicted the occurrence of postoperative coronary ischaemia after CEA. The odds ratio for coronary angiography (group A) indicated that when holding all other variables constant, a patient having preoperative coronary angiography

  17. Optimal Treatment of the ‘High-Risk’ Patient with Carotid Artery Stenosis

    NARCIS (Netherlands)

    Fokkema, T.M.

    2013-01-01

    Four landmark randomized trials have clearly validated the use of carotid endarterectomy (CEA) for the management of asymptomatic and symptomatic significant carotid artery stenosis. However, its risk-to-benefit ratio is variable for different patients. With the advent of carotid artery stenting

  18. Estudo prospectivo comparativo entre a endarterectomia e a angioplastia com stent e proteção cerebral no tratamento das lesões ateroscleróticas carotídeas: resultados em 30 dias Prospective and comparative study between endarterectomy and stent angioplasty with cerebral protection in carotid atherosclerotic lesions: 30-day results

    Directory of Open Access Journals (Sweden)

    Eugênio Carlos de Almeida Tinoco

    2006-12-01

    Full Text Available OBJETIVO: Analisar comparativamente os resultados, em 30 dias, entre a endarterectomia e a angioplastia com stent auto-expansível e filtro de proteção cerebral, avaliando a incidência de acidente vascular cerebral e óbito, bem como o tempo de permanência hospitalar no tratamento das lesões ateroscleróticas da bifurcação carotídea. MÉTODO: Estudo prospectivo, em que foram tratados 80 pacientes, sintomáticos e assintomáticos, com lesões estenóticas maiores que 60 e 70%, respectivamente, da bifurcação carotídea. Os pacientes foram divididos em dois grupos de 40 pacientes, que foram avaliados quanto a sexo, idade, comorbidades associadas e tabagismo. RESULTADOS: A taxa de acidente vascular cerebral e óbito foi de 5,0% em ambas as técnicas. Ocorreu um caso (2,5% de ataque isquêmico transitório no grupo endovascular e nenhum na endarterectomia. No que se refere ao tempo de internação, o tratamento endovascular apresentou menor tempo em relação à endarterectomia, sendo estatisticamente significativo (P OBJECTIVE: To comparatively analyze the 30-day results between endarterectomy and angioplasty using self-expandable stent and filter protection in the treatment of carotid bifurcation atherosclerotic lesions. The primary endpoint was to analyze stroke and death rate, as well hospitalization time. METHODS: Comparative and prospective study in 80 symptomatic and asymptomatic patients, with carotid bifurcation stenotic lesions greater than 60 and 70%, respectively. The patients were divided into two groups of 40 and assessed according to gender, age, associated comorbid conditions and smoking. RESULTS: The stroke and death rate was 5.0% for both techniques. There was only one case of transient ischemic attack (2.5% in the endovascular group. Regarding hospitalization time, it was significantly lower in favor of the endovascular technique, with statistical significance (P < 0.002. CONCLUSIONS: This study demonstrated a 5

  19. Induction of cervical dilation for transcervical embryo transfer in ewes

    Science.gov (United States)

    2014-01-01

    Background A major limitation in the application of assisted reproductive technologies in sheep arises from the inability to easily traverse the uterine cervix. The cervix of the non-pregnant ewe is a narrow and rigid structure, with 5–7 spiral folds and crypts that block its lumen. The first two folds closest to the vagina appear to be the greatest obstacle for the instrument insertion into the sheep cervix. Therefore, the dilation of the distal part of the cervix could provide the conformational change necessary to perform non-invasive transcervical procedures. The present study set out to assess the efficacy of Cervidil®, a patented dinoprostone (PgE2)-containing vaginal insert with a controlled-release mechanism, to safely induce sufficient cervical dilation for the purpose of transcervical embryo transfer (TCET) in cyclic ewes. Methods The transfer of frozen-thawed ovine embryos was attempted in 22 cross-bred Rideau Arcott x Polled Dorset ewes, with or without the pre-treatment with Cervidil® for 12 or 24 h prior to TCET. Results Cervical penetration rate was significantly improved after Cervidil® pre-treatment, with 55% (6/11) of treated versus 9% (1/11) of control animals successfully penetrated (χ2-test, p ewes that were penetrated, 67% (4/6) had been exposed to Cervidil(R) for 24 h and 33% (2/6) had had a 12-h exposure (p > 0.05). Variations in the age, weight, genotype, parity, lifetime lamb production (LLP) and post-partum interval (PPI) between penetrated and non-penetrated ewes were not significant (p > 0.05). The time taken to traverse the uterine cervix was negatively correlated (p ewes, but no fetuses were detected ultrasonographically 55 days post-TCET. Conclusions The present results indicate a significant benefit of using Cervidil® for inducing cervical dilation during the mid-luteal phase in ewes but the reason(s) for impaired fertility after the transfer of frozen-thawed ovine embryos remains to be elucidated. PMID:24467737

  20. Technique of the transcervical-subxiphoid-videothoracoscopic maximal thymectomy

    Directory of Open Access Journals (Sweden)

    Zielinski Marcin

    2007-01-01

    Full Text Available Background: The aim of this study is to present the new technique of transcervical-subxiphoid-videothoracoscopic "maximal"thymectomy introduced by the authors of this study for myasthenia gravis. Materials and Methods: Two hundred and sixteen patients with Osserman scores ranging from I-III were operated on from 1/9/2000 to 31/12/2006 for this study. The operation was performed through four incisions: a transverse 5-8 cm incision in the neck, a 4-6 cm subxiphoid incision and two 1 cm incisions for videothoracoscopic (VTS ports. The cervical part of the procedure was performed with an open technique while the intrathoracic part was performed using a video-assisted thoracoscopic surgical (VATS technique. The whole thymus with the surrounding fatty tissue containing possible ectopic foci of the thymic tissue was removed. Such an operation can be performed by one surgical team (the one team approach or by two teams working simultaneously (two team approach. The early and late results as well as the incidence and localization of ectopic thymic foci have been presented in this report. Results: There were 216 patients in this study of which 178 were women and 38 were men. The ages of the patients ranged from 11 to 69 years (mean 29.7 years. The duration of myasthenia was 2-180 months (mean 28.3 months. Osserman scores were in the range of I-III. Almost 27% of the patients were taking steroids or immunosuppressive drugs preoperatively. The mean operative time was 201.5 min (120-330 min for a one-team approach and it was 146 (95-210 min for a two-team approach (P < 0.05. While there was no postoperative mortality, the postoperative morbidity was 12%. The incidence of ectopic thymic foci was 68.4%. The rates of complete remission after one, two, three, four and five years of follow-up were 26.3, 36.5, 42.9, 46.8 and 50.2%, respectively. Conclusion: Transcervical-subxiphoid-VTS maximal thymectomy is a complete and highly effective treatment modality for

  1. Coil Migration through a Neuroform 3 Stent during Endovascular Coiling. A Case Report.

    LENUS (Irish Health Repository)

    O'Hare, A

    2009-07-29

    Summary: A 43-year-old woman attended for stent assisted coiling. A Neuroform 30 x 4.5 mm stent had been successfully placed over the left periophthalmic aneurysm. During the coiling the first coil migrated through the crowns in the stent, lodging at the MCA bifurcation. We believe that the coil herniated through the overlying stent due to the carotid siphon curvature and the open cell design. Furthermore the distal markers of the stent impeded coil extraction with a MERCI device.

  2. Simulation model for transcervical laryngeal injection providing real-time feedback.

    Science.gov (United States)

    Ainsworth, Tiffiny A; Kobler, James B; Loan, Gregory J; Burns, James A

    2014-12-01

    This study aimed to develop and evaluate a model for teaching transcervical laryngeal injections. A 3-dimensional printer was used to create a laryngotracheal framework based on de-identified computed tomography images of a human larynx. The arytenoid cartilages and intrinsic laryngeal musculature were created in silicone from clay casts and thermoplastic molds. The thyroarytenoid (TA) muscle was created with electrically conductive silicone using metallic filaments embedded in silicone. Wires connected TA muscles to an electrical circuit incorporating a cell phone and speaker. A needle electrode completed the circuit when inserted in the TA during simulated injection, providing real-time feedback of successful needle placement by producing an audible sound. Face validation by the senior author confirmed appropriate tactile feedback and anatomical realism. Otolaryngologists pilot tested the model and completed presimulation and postsimulation questionnaires. The high-fidelity simulation model provided tactile and audio feedback during needle placement, simulating transcervical vocal fold injections. Otolaryngology residents demonstrated higher comfort levels with transcervical thyroarytenoid injection on postsimulation questionnaires. This is the first study to describe a simulator for developing transcervical vocal fold injection skills. The model provides real-time tactile and auditory feedback that aids in skill acquisition. Otolaryngologists reported increased confidence with transcervical injection after using the simulator. © The Author(s) 2014.

  3. Cerebral intolerance during flow arrested carotid angioplasty.

    Science.gov (United States)

    St Louis, Myron; Park, Brian D; Dahn, Michael; Bozeman, Patricia

    2012-01-01

    The use of flow arrest as a means of providing cerebral protection during carotid angioplasty offers the advantages of improved efficiency of debris removal and the ability to provide protection under unfavorable (tortuous) anatomic circumstances. However, in contrast to the filtration methods of cerebral protection, this modality requires complete interruption of antegrade carotid artery flow during balloon angioplasty and stent deployment. We report our experience with 9 patients undergoing carotid angioplasty with the Mo.Ma device, which utilizes common and external carotid artery balloon occlusion during the angioplasty procedure. We assessed the clinical outcomes and intraprocedural hemodynamic data. The average duration of carotid occlusion was 8.3 minutes. Of the 9 patients, 2 patients (22%) experienced cerebral intolerance. No stroke occurred in this patient cohort. There appeared to be a poor relationship between procedure intolerance and the presence of significant contralateral stenosis or low carotid back pressure. Furthermore, the incidence of postangioplasty hypotension was not clearly related to cerebral intolerance. Carotid angioplasty with stenting can be safely conducted with flow arrest as an alternative to filter-type cerebral protection devices. However, because cerebral intolerance is not an infrequent occurrence with this approach, clinicians must be cognizant of management strategies for transient cerebral intolerance.

  4. MR Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    Directory of Open Access Journals (Sweden)

    Matthias C. Burg

    2011-01-01

    Full Text Available Purpose. To evaluate stent lumen visibility of a large sample of different peripheral arterial (iliac, renal, carotid stents using magnetic resonance angiography in vitro. Materials and Methods. 21 different stents and one stentgraft (10 nitinol, 7 316L, 2 tantalum, 1 cobalt superalloy, 1 PET + cobalt superalloy, and 1 platinum alloy were examined in a vessel phantom (vessel diameters ranging from 5 to 13 mm filled with a solution of Gd-DTPA. Stents were imaged at 1.5 Tesla using a T1-weighted 3D spoiled gradient-echo sequence. Image analysis was performed measuring three categories: Signal intensity in the stent lumen, lumen visibility of the stented lumen, and homogeneity of the stented lumen. The results were classified using a 3-point scale (good, intermediate, and poor results. Results. 7 stents showed good MR lumen visibility (4x nitinol, 2x tantalum, and 1x cobalt superalloy. 9 stents showed intermediate results (5x nitinol, 2x 316L, 1x PET + cobalt superalloy, and 1x platinum alloy and 6 stents showed poor results (1x nitinol, and 5x 316L. Conclusion. Stent lumen visibility varies depending on the stent material and type. Some products show good lumen visibility which may allow the detection of stenoses inside the lumen, while other products cause artifacts which prevent reliable evaluation of the stent lumen with this technique.

  5. High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

    International Nuclear Information System (INIS)

    Nemes, Balazs; Lukacs, Levente; Balazs, Gyoergy; Dosa, Edit; Berczi, Viktor; Huettl, Kalman

    2009-01-01

    Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 ± 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 ± 8% before the procedure to 15.7 ± 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

  6. Pseudoaneurisme på arteria carotis interna behandlet med stent

    DEFF Research Database (Denmark)

    Benian, Cemil; Wagner, Aase; Cortsen, Marie

    2013-01-01

    Extracranial internal carotid artery aneurysms (EACIAs) are rare. Untreated they have a high stroke rate. Traditionally the treatment has been surgery or endovascular intervention with coils. Both are associated with relatively high complication rates. Another treatment option is endovascular int...... intervention with covered stent, which provides one-step closure of the aneurysm. As in the case story it can be complicated with in-stent occlusion. Therefore we recommend balloon occlusion test before treatment of EACIAs with covered stent....

  7. "Forgotten" Chapters in the History of Transcervical Sterilization: Carl Clauberg and Hans-Joachim Lindemann.

    Science.gov (United States)

    Hildebrandt, Sabine; Benedict, Susan; Miller, Erin; Gaffney, Michael; Grodin, Michael A

    2017-07-01

    Transcervical sterilization is a non-surgical method of permanent female sterilization that is widely used and critically discussed. A review of the historiography of the method reveals that instances of its coercive use are not included in the historical account. This study offers a reexamination of the work of Carl Clauberg and Hans-Joachim Lindemann, to more deeply contextualize within the framework of current usage the coercive use of transcervical sterilization during the Third Reich and in postwar Germany. This inquiry is based on postwar criminal trial records on Clauberg, and on archival documents detailing Lindemann's activities in 1979. A comparative analysis examines arguments by medical historian Karl-Heinz Roth, and identifies shared characteristics and differences between Clauberg and Lindemann, their methods and scientific connections. The results demonstrate that the technique of transcervical sterilization has an abusive potential that may be explained as a function of the person of the physician, of the scientific method itself, and of societal and political influences. The analysis supports the argument that insights from the cases of Clauberg and Lindemann are transferrable geographically and over time, and have the potential to inform current medical practice, such as transcervical sterilization with the Essure device, whose historiographic exploration remains a desideratum. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. Percutaneous implantation of endoprostheses in the carotid arteries

    Directory of Open Access Journals (Sweden)

    Costa Jr. José Ribamar

    2003-01-01

    Full Text Available OBJECTIVE: To assess the in-hospital evolution of patients undergoing percutaneous stent placement in the carotid arteries. METHODS: From August 1996 to April 2001, we studied 86 patients with carotid arterial obliterative lesions > 70% who were treated with percutaneous stent placement in the carotid arteries. We assessed the rate of success of the implantation and of the procedure, the types of stents used, mortality rate, and neurological complications. RESULTS: Successful implantation was obtained in 98.9% of the cases, and the procedure was successful in 91.8%. The Wallstent was the most frequently used stent (73 patients - 77%. Cerebral strokes occurred as follows: 3 (3.2% transient ischemic attacks, 1 (1.1% minor stroke, and 3 (3.1% major strokes. One (1.1% patient died during hospitalization. CONCLUSION: The high rate of success of stent implantation (98.9% in addition to the low rate of cerebral stroke/death (4.2% showed the efficiency and safety of percutaneous stent placement in carotid arteries.

  9. Diagnostic workup in carotid stenosis - a neurologist's perspective

    International Nuclear Information System (INIS)

    Rosenkranz, Michael; Gerloff, Christian

    2010-01-01

    Carotid artery stenosis is associated with the risk of stroke, myocardial infarction, and vascular death. In selected patients, revascularization of carotid narrowing by endarterectomy may reduce the risk of stroke distal to the stenosis. Carotid artery stenting has evolved as a potential alternative to endarterectomy. Four randomized clinical trials comparing safety and efficacy of endarterectomy versus stenting of symptomatic carotid stenosis have been published in recent years, but there remains some uncertainty about the implications of these trials for clinical routine. Both carotid stenting and endarterectomy are based on different treatment strategies which may result in different specific risk factors associated with each procedure. Hence, the procedural risk of either modality varies not only with the skills of the surgeon or the interventionalist but may depend on patient characteristics. It appears that the most important question is not whether one revascularization modality is superior but for which patient one modality is better than the other. A comprehensive diagnostic workup of patients with carotid stenosis based on a broad panel of covariates that affect the risk of vascular events may improve selection of patients for carotid revascularization and may help to decide for whom one revascularization modality is likely to be better than the other. (orig.)

  10. Stent-assisted angioplasty for intracranial atherosclerosis

    International Nuclear Information System (INIS)

    Nakahara, Toshinori; Sakamoto, Shigeyuki; Hamasaki, Osamu; Sakoda, Katsuaki

    2002-01-01

    We report on two patients with intracranial atherosclerosis of the carotid artery or vertebral artery treated with stent-assisted angioplasty. Both patients have severe intracranial atherosclerosis (>70%) with refractory symptoms despite optimal medical treatment. In both patients, a coronary balloon-expandable stent was successfully placed using a protective balloon technique without procedural complications. The patients were asymptomatic and neurologically intact at a mean clinical follow-up of 13 months. Follow-up angiograms did not show restenosis 3 or 4 months after procedure, respectively. Stent-assisted angioplasty for intracranial atherosclerosis in the elective patient has proven effective, with an acceptable low rate of morbidity and mortality. (orig.)

  11. Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.

    Science.gov (United States)

    Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma

    2016-01-01

    Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.

  12. Transcervical Sterilization: A Comparison of Essure® Permanent Birth Control System and Adiana® Permanent Contraception System

    Science.gov (United States)

    Palmer, Sophia N; Greenberg, James A

    2009-01-01

    Transcervical sterilization has moved female sterilization from a minimally invasive laparoscopic technique, which requires entry into the abdominal cavity, to a less invasive hysteroscopic procedure. Along with the decreased potential for complications, its ease of performance with minimal anesthesia has facilitated a move from the operating room to the office. This review compares the available data on transcervical sterilization procedures to better understand the strengths and weakness of each system. PMID:19609402

  13. Successful Laparoscopically Assisted Transcervical Suction Evacuation of Interstitial Pregnancy following Failed Methotrexate Injection in a Community Hospital Setting

    Directory of Open Access Journals (Sweden)

    Rani B. Fritz

    2014-01-01

    Full Text Available We report on a case of a patient with an early diagnosed cornual ectopic pregnancy following failed methotrexate treatment. The patient was subsequently taken to the operating room for a laparoscopic guided transcervical suction curettage of the cornual ectopic. The surgery was successful and the patient was followed up until her urine pregnancy test was negative. We conclude that in properly selected patients, cornual ectopic pregnancy may be treated with transcervical suction curettage.

  14. Expandable stents.

    Science.gov (United States)

    Nesbitt, J C; Carrasco, H

    1996-05-01

    Expandable metallic stents are effective in selected patients with malignant or benign airway stenoses. When used for malignant lesions, the primary purpose of the stent is to improve the quality of life; stents are usually chosen for palliation of symptoms in recognition of the low likelihood of success for other therapy. For patients with benign stenoses, the stents provide a permanent source of structural support to alleviate the narrowed segment. The advantages of the expandable metallic stents are as follows: (1) they can be inserted through an endotracheal tube or under local anesthesia with relative simplicity under fluoroscopic guidance; (2) they do not impair the drainage of sputum because ciliary movement is not interrupted; (3) over a period of a few weeks, the meshwork is gradually covered with mucosa as the stent becomes incorporated into the airway wall; (4) ventilation usually is not impaired if the metallic mesh stent covers another nonstenosed bronchus, because the interstices of the stent are nonobstructive; and (5) they are dynamic and continue to expand over time, particularly if concurrent treatment achieves an effect on the lesion that caused stenosis. Disadvantages of the expandable stent include (1) they often are only temporarily effective for tracheobronchial stenosis due to intraluminal tumor or granulation tissue, both of which can grow between the wires; (2) they are considered permanent stents because removal is difficult; and (3) they can be poorly positioned during placement or can become displaced by progressive migration after placement, and they cannot be repositioned. A relative contraindication to insertion is an inflammatory process or infection that can predispose to granulation formation, particularly at the points of maximal contact pressure of the stent to the airway mucosa. In the presence of inflammation, it may be better to use a silicone prosthesis until the inflammatory process subsides and fibrosis occurs. Granulation

  15. Angioplasty of symptomatic high-grade internal carotid artery stenosis with intraluminal thrombus: therapeutic approach

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, A.; Mayol, A. [Seccion de Neurorradiologia Intervencionista, Servicio de Radiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Gil-Peralta, A.; Gonzalez-Marcos, J.R. [Servicio de Neurologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Boza, F. [Servicio de Neurofisiologia, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain); Ruano, J. [Unidad de Cuidados Intensivos, Hospital Universitario Virgen del Rocio, Avenida Manuel Siurot s/n, 41013, Sevilla (Spain)

    2004-04-01

    Intraluminal thrombus in the internal carotid artery (ICA) is usually found in patients with severe atheromatous stenosis. Having reviewed 300 carotid angioplasties for symptomatic >70% ICA stenosis, we found three patients (1%) with intraluminal thrombus. Conservative treatment with anticoagulants and double antiplatelet coverage can result in lysis of the thrombus without severe risks. Percutaneous transluminal angioplasty and stenting, preferably with distal protection, can be an excellent alternative to carotid endarterectomy. (orig.)

  16. Missed Total Occlusion Due to the Occipital Artery Arising from the Internal Carotid Artery

    International Nuclear Information System (INIS)

    Ustunsoz, Bahri; Gumus, Burcak; Koksal, Ali; Koroglu, Mert; Akhan, Okan

    2007-01-01

    A 56-year-old man was referred for digital subtraction angiography (DSA) with an ultrasound diagnosis of right proximal internal carotid artery (ICA) stenosis for possible carotid artery stenting. DSA revealed total occlusion of the ICA and an occipital artery arising from the stump and simulating continuation of the ICA. An ascending pharyngeal artery also arose from the same occipital artery. This case is of interest because this is a rare variation besides being a cause of misdiagnosis at carotid ultrasound

  17. Comparison of diamond-like carbon-coated nitinol stents with or without polyethylene glycol grafting and uncoated nitinol stents in a canine iliac artery model

    Science.gov (United States)

    Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R

    2011-01-01

    Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363

  18. Airway stents

    Science.gov (United States)

    Keyes, Colleen

    2018-01-01

    Stents and tubes to maintain the patency of the airways are commonly used for malignant obstruction and are occasionally employed in benign disease. Malignant airway obstruction usually results from direct involvement of bronchogenic carcinoma, or by extension of carcinomas occurring in the esophagus or the thyroid. External compression from lymph nodes or metastatic disease from other organs can also cause central airway obstruction. Most malignant airway lesions are surgically inoperable due to advanced disease stage and require multimodality palliation, including stent placement. As with any other medical device, stents have significantly evolved over the last 50 years and deserve an in-depth understanding of their true capabilities and complications. Not every silicone stent is created equal and the same holds for metallic stents. Herein, we present an overview of the topic as well as some of the more practical and controversial issues surrounding airway stents. We also try to dispel the myths surrounding stent removal and their supposed use only in central airways. At the end, we come to the long-held conclusion that stents should not be used as first line treatment of choice, but after ruling out the possibility of curative surgical resection or repair. PMID:29707506

  19. Invasive treatment for carotid fibromuscular dysplasia

    Science.gov (United States)

    Maciejewski, Damian R.; Dzierwa, Karolina; Kabłak-Ziembicka, Anna; Michalski, Michał; Wójcik-Pędziwiatr, Magdalena; Brzychczy, Andrzej; Moczulski, Zbigniew; Żmudka, Krzysztof; Pieniążek, Piotr

    2015-01-01

    Introduction Fibromuscular dysplasia (FMD) is an infrequent non-inflamatory disease of unknown etiology that affects mainly medium-size arteries. The prevalence of FMD among patients scheduled for endovascular treatment of carotid artery stenosis is unknown. Aim To evaluate the prevalence and treatment options of carotid FMD in patients scheduled for carotid artery stenting (CAS). Material and methods Between Jan 2001 and Dec 2013, 2012 CAS procedures were performed in 1809 patients (66.1% men; age 65.3 ±8.4 years, 49.2% symptomatic). In case of FMD suspicion in Doppler-duplex ultrasound (DUS), computed tomography angiography was performed for aortic arch and extracranial and intracranial artery imaging. For invasive treatment of FMD carotid stenosis, balloon angioplasty was considered first. If the result of balloon angioplasty was not satisfactory (> 30% residual stenosis, dissection), stent placement was scheduled. All patients underwent follow-up DUS and neurological examination 3, 6 and 12 months after angioplasty, then annually. Results There were 7 (0.4%) (4 symptomatic) cases of FMD. The FMD group was younger (47.9 ±7.5 years vs. 67.2 ±8.9 years, p = 0.0001), with higher prevalence of women (71.4% vs. 32.7%, p = 0.0422), a higher rate of dissected lesions (57.1% vs. 4.6%, p = 0.0002) and less severe stenosis (73.4% vs. 83.9%, p = 0.0070) as compared to the non-FMD group. In the non-FMD group the prevalence of coronary artery disease was higher (65.1% vs. 14.3% in FMD group, p = 0.009). All FMD patients underwent successful carotid artery angioplasty with the use of neuroprotection devices. In 4 cases angioplasty was supported by stent implantation. Conclusions Fibromuscular dysplasia is rare among patients referred for CAS. In case of significant FMD carotid stenosis, it may be treated with balloon angioplasty (stent supported if necessary) with optimal immediate and long-term results. PMID:26161104

  20. Self-made Palmaz stent: an experimental swine model study

    International Nuclear Information System (INIS)

    He Shicheng; Teng Gaojun; Guo Jinhe; Fang Wen

    2000-01-01

    Objective: To investigate the histologic changes and physicochemical stability of self-made Palmaz stent placed in swine arteries. Methods: The self-made Palmaz stent was made of 316L stainless steel wire. Nine stents were respectively placed within internal carotid, renal and iliac arteries of six pigs. Pigs were euthanized at intervals of 0.5, 1 and 3 months respectively and angiography were performed. Immediately followed by light and electro scanning microscopy for the stent zones. Results: All stents were successfully implanted in the target arteries and were patent shown in the angiographic examination immediately after the stent placement. Eight stents (8/9) remained patent at the time before euthanasia. No migration of stent were shown in the follow-up angiography. Light and electron scanning microscopy showed that the surface of the stents was covered by a thin layer of endothelial cells 2 weeks after the procedure and completely covered after 4 weeks. No inflammation occurred. Conclusions: The self-made Palmaz stent has good physicochemical stability and histocompatibility with easy placement, rather long term patency, histopathologic stability and thus the promising for clinical application

  1. Role of intrapartum transcervical amnioinfusion in patients with meconium-stained amniotic fluid.

    Science.gov (United States)

    Bhatia, Pushpa; Reena, Kumari; Nangia, Sangita

    2013-03-01

    The study was undertaken to evaluate maternal, perinatal outcomes following transcervical intrapartum amnioinfusion in women with meconium-stained amniotic fluid. A prospective comparative study was conducted on 100 women with meconium-stained amniotic fluid in labor. Group A: study group (50 cases) received amnioinfusion. Group B: control group (50 cases) did not receive amnioinfusion. FHR monitoring was done using cardiotocography. Significant relief from variable decelerations was seen in 68.18 % cases in the amnioinfusion group as compared to 7.1 % cases in the control group. 78 % cases who were given amnioinfusion had vaginal delivery as compared to 18 % cases in the control group. Fourteen percent cases in the study group had cesarean delivery as compared to 68 % cases in the control group. Meconium aspiration syndrome was seen in six percent neonates in the study group as compared to 20 % in the control group. Two neonates died in the control group due to meconium aspiration syndrome. There was no maternal mortality or major maternal complication. Intrapartum transcervical amnioinfusion is valuable in patients with meconium-stained amniotic fluid.

  2. ROLE OF TRANSCERVICAL AMNIOINFUSION IN LABOUR COMPLICATED WITH THICK MECONIUM STAINED LIQUOR

    Directory of Open Access Journals (Sweden)

    Anuragamayi

    2015-10-01

    Full Text Available OBJECTIVE: This is to evaluate the effectiveness of amnio infusion in cases of thick and particulate meconium stained liquor to reduce the incidence of fetal distress and meconium aspiration syndrome in neonates and compare neonatal outcome with control group . METHODS: A prospective comparative case control study was conducted in the Department of Obstetrics and gynecology, Government General Hospital, Kakinada. A total of 100 cases of labour complicated with thick meconium stained liquor were studied of which in 50 cases Transcervical Amnioinfusion was given and remaining 50 cases without amnioinfusion were taken as controls. The statistical analysis of neonatal outcome was done by Chi square test analysis of variance and paired t test. Liquor to reduce the incidence of fetal distress and meconium aspiration syndrome in neonates and compare neonatal. RESULTS: Operative interventions for fetal distress were significantly less in infusion group (p7 were observed in more cases of infusion group with significant difference in control group. Use of resuscitative measures for neonates were relatively more in control group with higher incidence of meconium at and below vocal cords (p <0.01. In amnioinfusion group, admissions in NICU were less (p <0.01 CONCLUSION : Transcervical amnioinfusion during labour is a safe, simple, inexpensive and effective procedure in improving the obstetric and perinatal outcome in patients labouring with thick meconium stained liquor

  3. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  4. Transcervical double-balloon catheter as an alternative and salvage method for medical termination of pregnancy in midtrimester

    Directory of Open Access Journals (Sweden)

    Yi-An Tu

    2017-02-01

    Conclusion: There was no significant additional benefit of using a double-balloon catheter in midtrimester termination of pregnancy, although the technique was considered simple and generally well-tolerated. Placing a transcervical double-balloon catheter could be the primary method, or one of the alternative medical methods if the patient and/or obstetrician prefers no operation.

  5. Development and pilot feasibility study of a health information technology tool to calculate mortality risk for patients with asymptomatic carotid stenosis: the Carotid Risk Assessment Tool (CARAT)

    OpenAIRE

    Faerber, Adrienne E; Horvath, Rebecca; Stillman, Carey; O?Connell, Melissa L; Hamilton, Amy L; Newhall, Karina A; Likosky, Donald S; Goodney, Philip P

    2015-01-01

    Background Patients with no history of stroke but with stenosis of the carotid arteries can reduce the risk of future stroke with surgery or stenting. At present, a physicians? ability to recommend optimal treatments based on an individual?s risk profile requires estimating the likelihood that a patient will have a poor peri-operative outcomes and the likelihood that the patient will survive long enough to gain benefit from the procedure. We describe the development of the CArotid Risk Assess...

  6. Reverse waffle cone technique in management of stent dislodgement into intracranial aneurysms.

    Science.gov (United States)

    Luo, Chao-Bao; Lai, Yen-Jun; Teng, Michael Mu-Huo; Chang, Feng-Chi; Lin, Chung-Jung; Guo, Wan-Yuo

    2013-09-01

    Stent-assisted coil embolization (SACE) is a common method to manage intracranial wide-neck aneurysm. Using this technique, a stent must be successfully deployed into the parent artery to cross the aneurysm neck. We describe the reverse waffle cone technique in management of intra-procedural stent dislodgement during SACE of internal carotid artery (ICA) wide-neck aneurysms. Two patients with unruptured wide-neck ICA aneurysms underwent SACE. Intra-procedural forward stent migration occurred during catheterization with proximal stent dislodgement and migration into the aneurysm sac. Navigation of a second stent to bridge the aneurysm neck failed in one patient because the second stent was impeded by the dislodged stent. Using the reverse waffle cone technique, a microcatheter was navigated into the aneurysm sacs. Coils were safely detached into each aneurysm sac without any device assistance. The two wide-neck aneurysms were successfully treated with preservation of flow to the internal carotid arteries. The complication of intra-procedural distal stent migration and dislodgement, with proximal stent prolapse into an aneurysm sac, may not result in a failure to coil the aneurysm. The reverse waffle cone technique provides an effective treatment in the management of this complication. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Experiences with carotid endarterectomy at Sree Chitra Tirunal Institute

    Directory of Open Access Journals (Sweden)

    Unnikrishnan Madathipat

    2008-01-01

    Full Text Available Background: Atherosclerotic carotid artery disease poses a grave threat to cerebral circulation, leading to a stroke with its devastating sequelae, if left untreated. Carotid endarterectomy has a proven track record with compelling evidence in stroke prevention. Objectives: aTo confirm that carotid endarterectomy (CEA is safe and effective in preventing stroke at both short and long term. b to demonstrate long term patency of internal carotid artery when arteriotomy repair is performed using autologous saphenous vein patch. Materials and Methods: During ten years, from September 1997 to February 2008, thirty nine patients who underwent consecutive carotid endarterectomy at our institute, form the basis of this report. Their age ranged from thirty to seventy eight years, with a mean age of 56. There were four women in this cohort. Thirty seven patients were symptomatic with> 70% stenosis and two were asymptomatic with> 80% stenosis, incidentally detected. Imaging included Duplex scan and MRA for carotid territory and brain, and non-invasive cardiac assessment. Co-morbidities included smoking, hypertension, diabetes, and coronary artery disease. Carotid Endarterectomy was performed under general anaesthesia, using carotid shunt and vein patch arteriotomy repair. Results: All the patients made satisfactory recovery, without major adverse cerebral events in this series. Morbidities included Transient Ischemic Attack (TIA in two, needing only medications in one, and carotid stenting in the other. Minor morbidities included neck hematoma in two and transient hypoglossal paresis in three patients. Yearly follow-up included duplex scan assessment for all the patients. Two patients died of contralateral stroke, two of myocardial events and two were lost to follow up. Thirty three patients are well and free of the disease during the follow up of three to 120 months. Conclusion: Carotid endarterectomy provided near total freedom from adverse cerebral

  8. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. Impact of myomas on the results of transcervical resection of the endometrium

    DEFF Research Database (Denmark)

    Christoffersen, Christian; Kahr, Henriette Strøm; Sørensen, Søren Stampe

    2014-01-01

    STUDY OBJECTIVE: To investigate long-term hysterectomy rates after transcervical resection of the endometrium (TCRE) performed by experienced surgeons in the presence and absence of intracavitary myomas. DESIGN: Multicenter case-control study (Canadian Task Force classification II-2). PATIENTS......: The study group comprised 456 women with myomas who met the inclusion criteria, and of these, 82 (17.98%) later underwent hysterectomy. The control group comprised 1438 women without myomas, and of these, 284 (19.75%) later underwent hysterectomy. METHODS: From 2001 to 2004, standardized results were...... AND MAIN RESULTS: After TCRE, women with type 2 myomas, compared with those with type 0 myomas, were found to have a significantly higher risk of undergoing hysterectomy (p = .04), and women, including controls, with myomas >3.6 cm in greatest diameter were found to have a significantly higher risk...

  10. Endovascular Treatment for Fusiform Dilation of Internal Carotid Artery Following Craniopharyngioma Resection: A Case Illustration.

    Science.gov (United States)

    Li, Qiang; Wang, Chaohua; Xu, Jianguo; You, Chao

    2015-09-01

    Fusiform dilation of the internal carotid artery complicates aggressive craniopharyngioma resection and occurs mainly in children. We report a case to describe the availability of endovascular treatment for this rare entity. A 13-year-old boy presented with headache for 2 years after resection of craniopharyngioma. A fusiform dilation of the right carotid artery was found and was coiled using stent-assisted technique. Follow-up showed satisfactory outcome and disappearance of headache. To our knowledge, this is the first report regarding endovascular treatment for fusiform dilation of the internal carotid artery after craniopharyngioma resection. Stent-assisted coiling is a useful approach for fusiform dilation of the internal carotid artery following craniopharyngioma surgery. © The Author(s) 2014.

  11. Surgical techniques and curative effect of carotid endarterectomy for carotid artery stenosis

    Directory of Open Access Journals (Sweden)

    Min HAN

    2014-02-01

    Full Text Available Objective To investigate the surgical techniques of carotid endarterectomy (CEA for treating carotid artery stenosis, in order to improve the surgical efficacy and reduce intraoperative adverse events and complications after operation. Methods Retrospective analysis was carried out on surgical data of 53 cases who were performed CEA from October 2010 to October 2013 in Department of Neurosurgery in Tianjin Huanhu Hospital. There were 39 males and 14 females, aged from 40 to 78 years old and mean age (60.34 ± 8.92 years old; the course of disease was from 2 d to 4 years. Twenty-six cases were diagnosed as right carotid stenosis, 15 cases left carotid stenosis and 12 cases double-sided carotid stenosis. Among all of those cases, 35 cases were diagnosed as moderate stenosis (30%-69%, 16 cases severe stenosis (70%-99% , and 2 cases complete occlusion. Results Among 53 patients, 50 patients underwent CEA; 2 cases underwent CEA and aneurysm clipping; one case underwent stent removal surgery and CEA because restenosis was found after carotid artery stenting (CAS. Postoperative neck CTA and fMRI showed good morphology of carotid artery, fluent blood flow and improved cerebral perfusion after operation. All of those patients were followed up for 3 to 24 months. One case died of myocardial infarction; 2 cases appeared skin numbness on the operating side of the neck, and the symptom disappeared 3 months later; one case appeared hoarseness after operation; 3 cases experienced mild transient ischemic attack (TIA and the symptom disappeared 2 months later. No case of stroke was found. Conclusions CEA is a safe and effective surgical approach to treat carotid stenosis. Correct and reasonable choices of the surgical indications and skilled surgical technique are the key to ensure the success of operation and to improve efficacy of the therapy. doi:10.3969/j.issn.1672-6731.2014.02.006Video: http://www.cjcnn.org/index.php/cjcnn/pages/view/v14n2a6

  12. Symptomatic stent cast.

    LENUS (Irish Health Repository)

    Keohane, John

    2012-02-03

    Biliary stent occlusion is a major complication of endoscopic stent insertion and results in repeat procedures. Various theories as to the etiology have been proposed, the most frequently studied is the attachment of gram negative bacteria within the stent. Several studies have shown prolongation of stent patency with antibiotic prophylaxis. We report the case of stent occlusion from a cast of a previously inserted straight biliary stent; a "stent cast" in an 86-year-old woman with obstructive jaundice. This was retrieved with the lithotrypter and she made an uneventful recovery. This is the first reported case of a biliary stent cast.

  13. Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization

    International Nuclear Information System (INIS)

    Joo, Jin Yang; Ahn, Jung Yong; Chung, Young Sun; Han, In Bo; Chung, Sang Sup; Yoon, Pyeong Ho; Kim, Sang Heum; Choi, Eun Wan

    2005-01-01

    Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesion was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series

  14. Bilateral Carotid Artery Dissection after High Impact Road Traffic Accident

    OpenAIRE

    Michael Kelly; Marcus Bradley; Ankur Srivastava

    2008-01-01

    A 58 year old man was involved in a high impact road traffic incident and was admitted for observation. Asymptomatic for the first 24 hours, he collapsed with symptoms and signs consistent with a cerebrovascular accident. Computed tomography angiogram (CTA) and Magnetic resonance angiogram (MRA) demonstrated bilateral internal carotid artery dissections and a left middle cerebral artery infarct. It was not considered appropriate to attempt stenting or other revascularistation. The patient was...

  15. Recent Trends in Neuro-endovascular Treatment for Acute Ischemic Stroke, Cerebral Aneurysms, Carotid Stenosis, and Brain Arteriovenous Malformations.

    Science.gov (United States)

    Matsumaru, Yuji; Ishikawa, Eiichi; Yamamoto, Tetsuya; Matsumura, Akira

    2017-06-15

    The efficacy of mechanical thrombectomy with stent retrievers for emergent large vessel occlusion has been proved by randomized trials. Mechanical thrombectomy is increasingly being adopted in Japan since stent retrievers were first approved in 2014. An urgent clinical task is to offer structured systems of care to provide this treatment in a timely fashion to all patients with emergent large vessel occlusion. Treatment with flow-diverting stents is currently a preferred treatment option worldwide for large and giant unruptured aneurysms. Initial studies reported high rates of complete aneurysm occlusion, even in large and giant aneurysms, without delayed aneurysmal recanalization and/or growth. The Pipeline Embolic Device is a flow diverter recently approved in Japan for the treatment of large and giant wide-neck unruptured aneurysms in the internal carotid artery, from the petrous to superior hypophyseal segments. Carotid artery stenting is the preferred treatment approach for carotid stenosis in Japan, whereas it remains an alternative for carotid endarterectomy in Europe and the United States. Carotid artery stenting with embolic protection and plaque imaging is effective in achieving favorable outcomes. The design and conclusions of a randomized trial of unruptured brain arteriovenous malformations (ARUBA) trial, which compared medical management alone and medical management with interventional therapy in patients with an unruptured arteriovenous brain malformation, are controversial. However, the annual bleeding rate (2.2%) of the medical management group obtained from this study is worthy of consideration when deciding treatment strategy.

  16. Recommendations for Management of Patients with Carotid Stenosis

    Directory of Open Access Journals (Sweden)

    Arijana Lovrencic-Huzjan

    2012-01-01

    Full Text Available Stroke is a one of the leading causes of morbidity and mortality in the world. Carotid atherosclerosis is recognized as an important factor in stroke pathophysiology and represents a key target in stroke prevention; multiple treatment modalities have been developed to battle this disease. Multiple randomized trials have shown the efficacy of carotid endarterectomy in secondary stroke prevention. Carotid stenting, a newer treatment option, presents a less invasive alternative to the surgical intervention on carotid arteries. Advances in medical therapy have also enabled further risk reduction in the overall incidence of stroke. Despite numerous trials and decades of clinical research, the optimal management of symptomatic and asymptomatic carotid disease remains controversial. We will attempt to highlight some of the pivotal trials already completed, discuss the current controversies and complexities in the treatment decision-making, and postulate on what likely lies ahead. This paper will highlight the complexities of decision-making optimal treatment recommendations for patients with symptomatic and asymptomatic carotid stenosis.

  17. Comparing the Efficacy and Side Effects of Trans-Cervical Catheter and Vaginal Misoprostol on Cervical Ripening

    Directory of Open Access Journals (Sweden)

    F. Mallah

    2016-08-01

    Full Text Available Background: The success of labor induction is extremely dependent on the state of the cervix. There are various methods available in modern obstetrics practice for ripening the cervix, such as intravaginal prostaglandins and mechanical devices like transcervical catheters. Although plenty of studies have already compared the two methods for the unripened cervices, more studies are warranted in nulliparous patients only. This study aimed to compare the efficacy of intravaginal misoprostol tablets with transcervical Foley catheter for cervical ripening in nulliparous patients. Methods & Materials: In this randomized clinical trial, 120 nulliparous candidates for labor induction were recruited from two teaching centers in Tabriz within a 17-month period of time. All the enrolled cases had a live singleton fetus with cephalic presentation at term (≥37 weeks, on-admission Bishop Score≤4, intact membranes and reactive non-stress test results. They were randomly assigned to two equal age-matched groups receiving either intravaginal misoprostol (25 microgram, n=59, or transcervical insertion of 16F Foley catheter (n=60. Results: One time successful induction (i.e. successful induction after a single insertion of misoprostol, or expulsion of transcervical Foley catheter within 12 h of insertion was achieved in all the patients without employment of other methods such as use of syntocinon. Misoprostol was more effective in terms of induction-to-cervical ripening interval (15.16±3.59 h vs. 18.30±1.59 h; p<0.001. Tachysystole, on the other hand, was significantly more frequent in the misoprostol receivers (25.4% vs. 0%; p<0.001. The two groups were comparable for the rate of cesarean section (misoprostol, 37.3%; Folly catheter, 30%; p=0.40. Comparing the two groups, there was no significant difference with regard to change in Bishop Score (misoprostol, 1.90±0.54 h-1; Folly catheter, 1.89±0.74 h-1; p=0.95 and miscellaneous pregnancy-related and fetal

  18. Fluoroscopically Guided Transcervical Fallopian Tube Recanalization of Post-Sterilization Reversal Mid-Tubal Obstructions

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Anderson, David; Mills, John; Harrold, Anthony

    2000-01-01

    Purpose: To assess the technical success and early outcome of fluoroscopically guided transcervical fallopian tube recanalization (FTR) in mid-tubal occlusion following sterilization reversal surgery.Methods: From July 1995 to January 1998, patients with greater than 12 months secondary infertility underwent hysterosalpingography (HSG). FTR was performed in proximal or mid-tubal occlusion. Cases of FTR in mid-tubal occlusion were included in this study. Technical success (defined as complete tubal patency) using a standard guidewire and hydrophilic glidewire, the number of patients with at least one patent tube, and the intrauterine and ectopic pregnancy rates were determined.Results: Twenty-six infertile patients with previous sterilization reversal underwent HSG. Eight of 26 (31%) patients (mean age 32 years, range 23-37 years), had attempted FTR for mid-tubal occlusion at the site of surgical anastomosis. Fourteen tubes were attempted as there were two previous salpingectomies. Technical success was achieved in eight of 14 (57%) tubes attempted, resulting in five of eight (62%) patients having at least one patent tube. At follow-up (mean 18 months, range 12-28 months) in these five patients there was one intrauterine pregnancy. There were no ectopic pregnancies.Conclusions: FTR in mid-tubal obstruction in infertile patients following sterilization reversal surgery is technically feasible and may result in intrauterine pregnancy. In this small group there was a lower technical success rate and lower pregnancy rate than in unselected proximal tubal occlusion

  19. Potential advantages and limitations of the Leo stent in endovascular treatment of complex cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lv Xianli; Li Youxiang; Jiang Chuhan; Yang Xinjian [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China); Wu Zhongxue, E-mail: ttyyzjb@sina.com [Beijing Neurosurgical Institute and Beijing Tiantan Hospital, Capital Medical University, 6, Tiantan Xili, 100050 Hebei, Beijing (China)

    2011-08-15

    Objective: The Leo self-expandable stent is a new retractable stent that is delivered via a conventional catheter. The aim of this study was to evaluate the use of this stent for endovascular treatment of complex aneurysms. Methods: Twenty-eight complex cerebral aneurysms (27 saccular and 1 fusiform) in 28 patients were treated electively. They were located at the internal carotid artery (17), basilar trunk (3), anterior cerebral artery (1), anterior communicating artery (3), vertebral artery (2) and middle cerebral artery (2). One aneurysm exhibited recanalization after primary endovascular treatment without stent. Clinical outcome was assessed with the modified Glasgow Outcome Scale. Results: Deployment of Leo stent was successful in 26 lesions, and difficulties in stent positioning due to tortuous cerebral circulation in 2 cases, which were treated with Neuroform stent. Additional coil embolization was performed in 26 lesions. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in all aneurysms. There was no immediate coil embolization was chosen in 3 cases because of subsequent reduced filling of the aneurysms with contrast agent on angiograms. There were 3 asymptomatic parent artery occlusion related to the deployment of the Leo stent, one stent migration. Follow-up revealed patent stents in the remaining cases. No angiographic recurrences arose. Conclusion: The Leo stent is very useful for endovascular treatment of complex cerebral aneurysms because it is easy to navigate and place precisely. A drawback is that in-stent thrombosis caused by stent placement and stiffer delivery catheters to place larger stents.

  20. Reasons Underlying the Consent to Endovascular Treatment, Displayed by Patients Diagnosed with Asymptomatic Internal Carotid Artery Stenosis

    OpenAIRE

    Stanišić, Michał-Goran; Rzepa, Teresa

    2014-01-01

    Background Endovascular treatment of internal carotid artery stenosis (ICAS) has gained popularity in recent years. Offering CAS, which is a controversial treatment in asymptomatic disease, may provoke patient distrust of the diagnosis and intervention benefit. The aim of this study was to prove that asymptomatic ICAS patients tend to show an emotional attitude to their illness, and therefore their decisions regarding carotid artery stenting are externally motivated and assessed emotionally. ...

  1. Laparoscopic Supracervical Hysterectomy With Transcervical Morcellation and Sacrocervicopexy: Initial Experience With a Novel Surgical Approach to Uterovaginal Prolapse

    Science.gov (United States)

    Rosenblatt, Peter L.; Apostolis, Costas A.; Hacker, Michele R.; DiSciullo, Anthony

    2013-01-01

    The objective of this retrospective study was to evaluate the feasibility, safety, and efficacy of a new laparoscopic technique for the treatment of uterovaginal prolapse using a transcervical access port to minimize the laparoscopic incision. From February 2008 through August 2010, symptomatic pelvic organ prolapse in 43 patients was evaluated and surgically treated using this novel procedure. Preoperative assessment included pelvic examination, the pelvic organ prolapse quantification scoring system (POP-Q), and complex urodynamic testing with prolapse reduction to evaluate for symptomatic or occult stress urinary incontinence. The surgical procedure consisted of laparoscopic supracervical hysterectomy with transcervical morcellation and laparoscopic sacrocervicopexy with anterior and posterior mesh extension. Concomitant procedures were performed as indicated. All procedures were completed laparoscopically using only 5-mm abdominal port sites, with no intraoperative complications. Patients were followed up postoperatively for pelvic examination and POP-Q at 6 weeks, 6 months, and 12 months. The median (interquartile range) preoperative POP-Q values for point Aa was 0 (−1.0 to 1.0), and for point C was −1.0 (−3.0 to 2.0). Postoperatively, median points Aa and C were significantly improved at 6 weeks, 6 months, and 12 months (all p < .001). One patient was found to have a mesh/suture exposure from the sacrocervicopexy, which was managed conservatively without surgery. We conclude that laparoscopic supracervical hysterectomy with transcervical morcellation and laparoscopic sacrocervicopexy is a safe and feasible surgical approach to treatment of uterovaginal prolapse, with excellent anatomic results at 6 weeks, 6 months, and 12 months. Potential advantages of the procedure include minimizing laparoscopic port site size, decreasing the rate of mesh exposure compared with other published data, and reducing the rate of postoperative cyclic bleeding in

  2. Treatment of a spontaneous intracranial dissecting aneurysm with stent-assisted coil embolization

    International Nuclear Information System (INIS)

    Irie, Keiko; Negoro, Makoto; Hayakawa, Motoharu; Hayashi, Junichi; Kanno, Tetsuo

    2003-01-01

    Arterial dissection is now recognized as an important cause of stroke. Most reported dissections involve the extracranial portion of the internal carotid artery (ICA) and vertebral arteries. Spontaneous dissecting aneurysms of the intracranial ICA are uncommon. Endovascular treatment for cerebral aneurysms has become widespread; however, the dissecting aneurysm is still difficult to treat if the parent artery has to be preserved. More recently, stenting has been advocated for use with endosaccular coiling, with the coils held in place by the stent. We herein report a spontaneous intracranial ICA dissecting aneurysm in a 51-year-old woman who was treated using a new technique of combined stent and coils. (orig.)

  3. In-stent stenosis after stent-assisted coiling: incidence, predictors and clinical outcomes of 435 cases.

    Science.gov (United States)

    Chalouhi, Nohra; Drueding, Ross; Starke, Robert M; Jabbour, Pascal; Dumont, Aaron S; Gonzalez, L Fernando; Rosenwasser, Robert; Tjoumakaris, Stavropoula

    2013-03-01

    Neuroform and Enterprise are widely used self-expanding stents designed to treat wide-necked intracranial aneurysms. To assess the incidence, clinical significance, predictors, and outcomes of in-stent stenosis (ISS). Angiographic studies and hospital records were retrospectively reviewed for 435 patients treated between 2005 and 2011 in our institution. A multivariable regression analysis was conducted to determine the predictors of ISS. The Neuroform stent was used in 264 patients (60.7%) and the Enterprise in 171 patients (39.3%). A total of 11 patients (2.5%) demonstrated some degree of ISS during the follow-up period at a mean time point of 4.2 months (range, 2-12 months). The stenosis was mild ( 75%) in 1 patient (0.2%). No patients were symptomatic or required further intervention. There was complete ISS resolution in 2 patients, partial resolution in 2 patients, and no change in 5 patients on follow-up angiography. Patients developing ISS were significantly younger than those without ISS (40.3 vs. 54.9 years; P stent (P = .6). In multivariable analysis, younger patient age (odds ratio = 0.92; P = .008), carotid ophthalmic aneurysm location (odds ratio = 7.7; P =0.01), and carotid terminus aneurysm location (odds ratio = 8.1; P = .009) were strong independent predictors of ISS. The type of stent was not a predictive factor. Neuroform and Enterprise ISS is an uncommon, often transient, and clinically benign complication. Younger patients and those harboring anterior circulation aneurysms located at ophthalmic and carotid terminus locations are more likely to develop ISS.

  4. Stent angioplasty for the treatment of symptomatic stenosis of middle cerebral artery

    International Nuclear Information System (INIS)

    Lu Huisheng; Niu Huiming; Chao Yuanxiang; Li Xiaoning; Wu Dingfeng; Zhang Chenhong; Yang Jie; Zhang Liang

    2010-01-01

    Objective: To investigate the safety and feasibility of endovascular stent angioplasty in treating symptomatic stenosis of middle cerebral artery. Methods: Endovascular angioplasty with coronary stents was performed in 27 patients with symptomatic stenosis of middle cerebral artery. The clinical results were reviewed and analyzed. Results: Of the total 27 patients, successful placement of the coronary stents was achieved in 24. Angiography immediately after the procedure showed that the stenotic degree of the diseased artery was markedly decreased from preoperative (80 ± 19)% to postoperative (8 ±4)%, the improvement was very obvious. Percutaneous transcatheter angioplasty had to be employed in two cases because of the failure of stent placement. A mean follow-up period of 18 months was carried out. During the following up period no transient cerebral ischemia attack occurred in 25 patients and no newly-developed cerebral infarction in region fed by the responsible vessels occurred either.Re-irrigation cerebral hemorrhage was seen in one patient, which occurred three hours after the placement of the stent. In one case the placed stent fell off and immigrated into the siphon of internal carotid artery, and the displaced stent was took out later with a catching apparatus. In another case re-stenosis occurred six months after the stenting. Conclusion: Percutaneous endovascular stent angioplasty is a safe and effective treatment for symptomatic stenosis of middle cerebral artery, although its long-term results need to be further evaluated. (authors)

  5. Circumferential and fusiform intracranial aneurysms: reconstructive endovascular treatment with self-expandable stents

    Energy Technology Data Exchange (ETDEWEB)

    Lubicz, Boris [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Hopital Erasme, Service de Radiologie (EA 2691), Brussels (Belgium); Collignon, Laurent; Baleriaux, Danielle [Erasme University Hospital, Department of Neuroradiology, Brussels (Belgium); Lefranc, Florence; Bruneau, Michael; Brotchi, Jacques; Witte, Olivier de [Erasme University Hospital, Department of Neurosurgery, Brussels (Belgium)

    2008-06-15

    We report our experience with endovascular treatment (EVT) of circumferential and fusiform intracranial aneurysms by a reconstructive approach with self-expandable stents. A retrospective review of our prospectively maintained database identified all circumferential and fusiform aneurysms treated by a reconstructive endovascular approach over a 3-year period. Clinical charts, procedural data, and angiographic results were reviewed. From April 2004 to May 2007, 13 patients were identified, of whom 12 were asymptomatic and 1 presented with a subarachnoid hemorrhage. Two patients with an aneurysm {<=}2 mm were treated by stent-within-stent placement without coiling (group 1). In 11 patients with a larger aneurysm, stenting with subsequent coiling was performed (group 2). In this latter approach, a balloon was temporarily inflated within the stent to ensure safe coil delivery. All patients showed an excellent clinical outcome. Asymptomatic procedural complications occurred in three patients, two with cervical internal carotid artery dissection and one with retroperitoneal hematoma. In patients of group 1, the aneurysm had completely disappeared at 6 months. In patients of group 2, aneurysm occlusion was complete in three and incomplete in eight. Follow-up angiography in 12 patients showed four with further thrombosis, six with stable results, and two with minor recanalization. Circumferential and fusiform intracranial aneurysms may be treated by a reconstructive endovascular approach with self-expandable stents. In small aneurysms, a stent-within-stent technique is effective, whereas stenting and subsequent coiling is indicated in larger aneurysms. This therapeutic protocol is associated with good clinical and anatomical results. (orig.)

  6. Assessing the usefulness of prostaglandin E2 (Cervidil) for transcervical artificial insemination in ewes.

    Science.gov (United States)

    Bartlewski, Pawel M; Candappa, Ivanka B R

    2015-12-01

    The underlying theme of this study involved the evaluation of the dilatory effects of prostaglandin E2 on the ovine cervix and thus the assessment of its potential applicability to transcervical artificial insemination (TCAI) in ewes. A novel method of prostaglandin E2 administration (controlled slow-release vaginal inserts) was examined, and the practical implications of this approach including cervical penetrability and posttreatment pregnancy rates were evaluated. The Guelph method of TCAI was performed during the seasonal anestrus (n = 40) and the breeding season (n = 40) on multiparous Rideau Arcott × Polled Dorset ewes, with or without the pretreatment with Cervidil (for a duration of 12 hours or 24 hours before TCAI). Cervical penetration rates averaged 82.5% (66 of 80), and they varied neither (P > 0.05) between the two seasons nor between Cervidil-treated ewes and their respective controls. Cervidil priming significantly reduced the total time required for TCAI during the breeding season in comparison with controls (54 vs. 98 seconds), especially after the 24-hour exposure (38 vs. 108 seconds). The time taken to traverse the uterine cervix was negatively correlated (P ewes. Four out of 36 (11%) successfully penetrated ewes in the breeding season (three ewes allocated to the 12-hour control group and one ewe that had received Cervidil for 12 hours) became pregnant and carried the lambs to term. Vaginal mucus impedance at TCAI was significantly and positively correlated with the total time required to complete the procedure in cyclic ewes, and the negative correlation between vaginal mucus impedance and total time values at the time of controlled intravaginal drug release device removal approached to significance in anestrous ewes. The present results indicate a moderate benefit of using Cervidil for inducing cervical dilation before TCAI in ewes, mainly in the breeding season. The specific reason(s) for impaired fertility after the TCAI using

  7. Circumferential Stent Fracture: Novel Detection and Treatment with the Use of StentBoost

    OpenAIRE

    Ramegowda, Raghu T.; Chikkaswamy, Srinivas B.; Bharatha, Ashalatha; Radhakrishna, Jayashree; Krishnanaik, Geetha B.; Nanjappa, Manjunath C.; Panneerselvam, Arunkumar

    2012-01-01

    Circumferential stent fracture is extremely uncommon, and in rare cases, it can cause stent thrombosis. Recognizing stent fracture can be difficult on conventional fluoroscopy because of poor stent radiopacity. We found that StentBoost image acquisition yields improved visibility of stent struts, enabling the identification of stent fracture and the precise positioning of new stents over previously stented segments.

  8. Comparison of the occlusion of experiemntal craniojugular saccular aneurysms with covered stents

    International Nuclear Information System (INIS)

    Zhang Haixia; Li Minghua; Cheng Yingsheng; Fang Chun; Li Min

    2006-01-01

    Objective: To assess the effectiveness and biocompatibility of balloon-expanding, stainless steel stents covered with biomembrane (BM-SSS) and polyurethane membrane (PUM-SSS) in the treatment of experimental saccular aneurysms in a canine model and to observe the ablation of aneurysm with preservation of the parent vessel. Methods: Sixteen healthy mongrel canines were included in our study. 26 of 29 successful experimental aneurysms were treated with covered stents, another 3 were untreated to serve as controls. Altogether there were fourteen BM-SSS and twelve PUM-SSS were placed endovascularly in the common carotid arteries covering the orifice of the aneurysms. Control angiography was performed immediately after the procedure and after 2 weeks, 4 weeks and 12 weeks. According to grouping time, each aneurysm together with stented arteries was removed with animals alive for histopathological examination. Enumeration data was analyzed by Fisher's Exact Test using SPSS 10.0. Results: Before stent placement, angiography of the common carotid arteries showed round, saccular side-wall aneurysms and complex pattern of flow. Immediately after stent placement the aneurysmal pouches were no longer visible and the stented common carotid arteries remained widely patent. All controlled aneurysms and common carotid arteries have been patent and unchanged for 1 year. 13 of 14 stented common carotid arteries with BM-SSS and 3 of 12 with PUM-SSS remained widely patent. The complete patency rate of BM-SSS and PUM-SSS was significantly different (P=0.0008). Histological analysis indicated that all treated aneurysmal pouches were almost filled with thrombus, as well as with fibrotic reactive scar tissue. Stent wires were found to be located deep within the vessel wall and encased by an extension of the tunica intima. The endothelium of the two groups was already mature at 12 weeks, and various degree of degenerate cells were seen under the transmission electron microscopy. Conclusion

  9. Bilateral Carotid Artery Dissection after High Impact Road Traffic Accident

    Directory of Open Access Journals (Sweden)

    Michael Kelly

    2008-11-01

    Full Text Available A 58 year old man was involved in a high impact road traffic incident and was admitted for observation. Asymptomatic for the first 24 hours, he collapsed with symptoms and signs consistent with a cerebrovascular accident. Computed tomography angiogram (CTA and Magnetic resonance angiogram (MRA demonstrated bilateral internal carotid artery dissections and a left middle cerebral artery infarct. It was not considered appropriate to attempt stenting or other revascularistation. The patient was treated with heparin prior to starting warfarin. He made a partial recovery and was discharged to a rehabilitation facility. This case is a reminder of carotid dissection as an uncommon but serious complication of high speed motor vehicle accident, which may be silent initially. Literature Review suggests risk stratification before relevant radiological screening at risk patients. Significant advances in CTA have made it the diagnostic tool of choice, but ultrasound is an important screening tool.

  10. Staged bilateral carotid endarterectomy

    DEFF Research Database (Denmark)

    Schroeder, T; Sillesen, H; Engell, Hans Christian

    1986-01-01

    In a series of 56 staged bilateral carotid endarterectomies, new neurologic symptoms developed in 5% and 20% following the first and second procedure, respectively. All complications were transient or minor. The incidence of postendarterectomy hypertension was significantly higher following...... the second procedure, when operations were staged less than 3 weeks apart. A correlation between these hypertensive episodes and the occurrence of new neurologic symptoms could not be shown. However, as this correlation has been proved in several other reports, bilateral carotid endarterectomy is advised...... to be staged at least 3 weeks apart. In addition, a conservative attitude towards contralateral asymptomatic lesions is proposed....

  11. Body mass index and outcome after revascularization for symptomatic carotid artery stenosis

    Science.gov (United States)

    Greving, Jacoba P.; Hendrikse, Jeroen; Algra, Ale; Kappelle, L. Jaap; Becquemin, Jean-Pierre; Bonati, Leo H.; Brott, Thomas G.; Bulbulia, Richard; Calvet, David; Eckstein, Hans-Henning; Fraedrich, Gustav; Gregson, John; Halliday, Alison; Howard, George; Jansen, Olav; Roubin, Gary S.; Brown, Martin M.; Mas, Jean-Louis; Ringleb, Peter A.

    2017-01-01

    Objective: To determine whether the obesity paradox exists in patients who undergo carotid artery stenting (CAS) or carotid endarterectomy (CEA) for symptomatic carotid artery stenosis. Methods: We combined individual patient data from 2 randomized trials (Endarterectomy vs Angioplasty in Patients with Symptomatic Severe Carotid Stenosis and Stent-Protected Angioplasty vs Carotid Endarterectomy) and 3 centers in a third trial (International Carotid Stenting Study). Baseline body mass index (BMI) was available for 1,969 patients and classified into 4 groups: 120 days after randomization). This outcome was compared between different BMI strata in CAS and CEA patients separately, and in the total group. We performed intention-to-treat multivariable Cox regression analyses. Results: Median follow-up was 2.0 years. Stroke or death occurred in 159 patients in the periprocedural (cumulative risk 8.1%) and in 270 patients in the postprocedural period (rate 4.8/100 person-years). BMI did not affect periprocedural risk of stroke or death for patients assigned to CAS (ptrend = 0.39) or CEA (ptrend = 0.77) or for the total group (ptrend = 0.48). Within the total group, patients with BMI 25–<30 had lower postprocedural risk of stroke or death than patients with BMI 20–<25 (BMI 25–<30 vs BMI 20–<25; hazard ratio 0.72; 95% confidence interval 0.55–0.94). Conclusions: BMI is not associated with periprocedural risk of stroke or death; however, BMI 25–<30 is associated with lower postprocedural risk than BMI 20–<25. These observations were similar for CAS and CEA. PMID:28446644

  12. Contemporary carotid imaging: from degree of stenosis to plaque vulnerability.

    Science.gov (United States)

    Brinjikji, Waleed; Huston, John; Rabinstein, Alejandro A; Kim, Gyeong-Moon; Lerman, Amir; Lanzino, Giuseppe

    2016-01-01

    limited in sensitivity and specificity for detecting LRNC, plaque hemorrhage, and ulceration compared with MRI. Also summarized is how these advanced imaging techniques are being used in clinical practice to risk stratify patients with low- and high-grade carotid artery stenosis. For example, identification of IPH on MRI in patients with low-grade carotid artery stenosis is a risk factor for failure of medical therapy, and studies have shown that such patients may fair better with carotid endarterectomy (CEA). MR plaque imaging has also been found to be useful in identifying revascularization candidates who would be better candidates for CEA than carotid artery stenting (CAS), as high intraplaque signal on time of flight imaging is associated with vulnerable plaque and increased rates of adverse events in patients undergoing CAS but not CEA.

  13. Impact of Hypertriglyceridemia on Carotid Stenosis Progression under Normal Low-Density Lipoprotein Cholesterol Levels.

    Science.gov (United States)

    Kitagami, Masayuki; Yasuda, Ryuta; Toma, Naoki; Shiba, Masato; Nampei, Mai; Yamamoto, Yoko; Nakatsuka, Yoshinari; Sakaida, Hiroshi; Suzuki, Hidenori

    2017-08-01

    Dyslipidemia is a well-known risk factor for carotid stenosis progression, but triglycerides have attracted little attention. The aim of this study was to assess if serum triglycerides affect progression of carotid stenosis in patients with well-controlled low-density lipoprotein cholesterol (LDL-C) levels. This is a retrospective study in a single hospital consisting of 71 Japanese patients with internal carotid artery stenosis greater than or equal to 50% and normal serum LDL-C levels who underwent angiographic examination with or without the resultant carotid artery stenting or endarterectomy from 2007 to 2011, and were subsequently followed up for 4 years. Clinical factors including fasting serum triglyceride values were compared between the progression (≥10% increase in degree of carotid stenosis on ultrasonography) and the nonprogression groups. During 4 years, 15 patients (21.1%) had carotid stenosis progression on either side. Cox regression analysis demonstrated that symptomatic cases (hazard ratio [HR], 4.327; P = .019), coexisting intracranial arteriosclerotic stenosis (HR, 5.341; P = .005), and hypertriglyceridemia (HR, 6.228; P = .011) were associated with subsequent progression of carotid stenosis. Kaplan-Meier plots demonstrated that the progression-free survival rate was significantly higher in patients without hypertriglyceridemia and intracranial arteriosclerotic stenosis at baseline. Among patients with moderate to severe carotid stenosis and well-controlled LDL-C, hypertriglyceridemia was an important risk factor for progression of carotid stenosis irrespective of surgical treatments. It would be worthwhile to test if triglyceride-lowering medications suppress carotid stenosis progression. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  14. Transcervical Inoculation with Chlamydia trachomatis Induces Infertility in HLA-DR4 Transgenic and Wild-Type Mice.

    Science.gov (United States)

    Pal, Sukumar; Tifrea, Delia F; Zhong, Guangming; de la Maza, Luis M

    2018-01-01

    Chlamydia trachomatis is the leading cause of infection-induced infertility in women. Attempts to control this epidemic with screening programs and antibiotic therapy have failed. Currently, a vaccine to prevent C. trachomatis infections is not available. In order to develop an animal model for evaluating vaccine antigens that can be applied to humans, we used C. trachomatis serovar D (strain UW-3/Cx) to induce infertility in mice whose major histocompatibility complex class II antigen was replaced with the human leukocyte antigen DR4 (HLA-DR4). Transcervical inoculation of medroxyprogesterone-treated HLA-DR4 transgenic mice with 5 × 10 5 C. trachomatis D inclusion forming units (IFU) induced a significant reduction in fertility, with a mean number of embryos/mouse of 4.4 ± 1.3 compared to 7.8 ± 0.5 for the uninfected control mice ( P < 0.05). A similar fertility reduction was elicited in the wild-type (WT) C57BL/6 mice (4.3 ± 1.4 embryos/mouse) compared to the levels of the WT controls (9.1 ± 0.4 embryos/mouse) ( P < 0.05). Following infection, WT mice mounted more robust humoral and cellular immune responses than HLA-DR4 mice. As determined by vaginal shedding, HLA-DR4 mice were more susceptible to a transcervical C. trachomatis D infection than WT mice. To assess if HLA-DR4 transgenic and WT mice could be protected by vaccination, 10 4 IFU of C. trachomatis D was delivered intranasally, and mice were challenged transcervically 6 weeks later with 5 × 10 5 IFU of C. trachomatis D. As determined by severity and length of vaginal shedding, WT C57BL/6 and HLA-DR4 mice were significantly protected by vaccination. The advantages and limitations of the HLA-DR4 transgenic mouse model for evaluating human C. trachomatis vaccine antigens are discussed. Copyright © 2017 American Society for Microbiology.

  15. Modified nasolacrimal duct stenting

    International Nuclear Information System (INIS)

    Tian Min; Jin Mei; Chen Huanjun; Li Yi

    2008-01-01

    Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external nasal guide wire track can improve the successful rate of nasolacrimal duct stenting. (authors)

  16. Auxetic coronary stent endoprosthesis

    DEFF Research Database (Denmark)

    Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar

    2014-01-01

    BACKGROUND: Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit...... a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable...... for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. METHODS: The auxetic design...

  17. Treatment of pseudoaneurysms with stent-graft: preliminary experience in 12 cases

    International Nuclear Information System (INIS)

    Liao Denghui; Ye Caisheng; Li Songqi; Ye Runyi; Chang Guangqi; Chen Wei; Li Xiaoxi; Wang Shenming

    2012-01-01

    Objective: To asses the clinical effect of stent-graft in the treatment of pseudoaneurysms. Methods: During the period from March 2008 to June 2011, 86 patients with pseudoaneurysms were admitted to the hospital, of whom stent-graft implantation was carried out in 12. The pseudoaneurysms were located at the thoracic aorta (n=4), abdominal aorta (n=3), common carotid artery (n=3), internal carotid artery (n=1) and right subclavian artery (n=1). All the patient were followed up for 5-43 months. The clinical results were analyzed. Results: The technical success rate for stent delivery was 100%. The pseudoaneurysms was immediately isolated after the procedure in all 12 cases. After endovascular exclusion with stent-graft, no leakage occurred and the blood flow distal to the parent artery was normal. All patients were followed up for a mean period of 23.5 months except one who lost in touch with the authors. One patient with coexisting Behcet's disease died of massive bleeding due to abdominal aortic rupture four months after operation. The other patients were in good clinical condition, and no complications such as stent stenosis, displacement, internal leakage etc. were observed in the follow-up period. Conclusion: The implantation of stent-graft has satisfactory short-term effect in treating pseudoaneurysms, although its long-term efficacy needs to be further observed. (authors)

  18. Clipping in Awake Surgery as End-Stage in a Complex Internal Carotid Artery Aneurysm After Failure of Multimodal Endovascular and Extracranial-Intracranial Bypass Treatment.

    Science.gov (United States)

    Cannizzaro, Delia; Peschillo, Simone; Mancarella, Cristina; La Pira, Biagia; Rastelli, Emanuela; Passacantilli, Emiliano; Santoro, Antonio

    2017-06-01

    Intracranial carotid artery aneurysm can be treated via microsurgical or endovascular techniques. The optimal planning is the result of the careful patient selection through clinical, anatomic, and angiographic analysis. We present a case of ruptured internal carotid artery (ICA) aneurysm that became a complex aneurysm after failure of multi-endovascular and surgery treatment. We describe complete trapping in awake craniotomy after failure of coiling, stenting, and bypassing. ICA aneurysms could become complex aneurysms following multi-treatment failure. Endovascular approaches to treat ICA aneurysms include coiling, stenting, flow diverter stenting, and stenting-assisted coiling technique. The role of surgery remains relevant. To avoid severe neurologic deficits, recurrence, and the need of retreatment, a multidisciplinary discussion with experienced endovascular and vascular neurosurgeons is mandatory in such complex cases. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  19. Translumbar carotid arteriography

    International Nuclear Information System (INIS)

    Maxwell, S.L. Jr.; Kwon, O.J.; Millan, V.G.

    1983-01-01

    In seven patients, carotid arteriography and arch aortography were performed using a translumbar catheter exchange sheath which facilitated selective catheterization. No significant complications occurred. The translumbar approach is easier than the auxillary approach, will result in fewer complications, and should be considered whenever a femoral arterial access is unavailable

  20. Transarterial endovascular treatment in the management of life-threatening carotid blowout syndrome in head and neck cancer patients: review of the literature.

    Science.gov (United States)

    Dequanter, D; Shahla, M; Paulus, P; Aubert, C; Lothaire, P

    2013-12-01

    Carotid blowout syndrome is a rare but devastating complication in patients with head and neck malignancy, and is associated with high morbidity and mortality. Bleeding from the carotid artery or its branches is a well-recognized complication following treatment or recurrence of head and neck cancer. It is an emergency situation, and the classical approach to save the patient's life is to ligate the carotid artery. But the surgical treatment is often technically difficult. Endovascular therapies were recently reported as good alternatives to surgical ligation. Retrospective review of three cases of acute or threatened carotid hemorrhage managed by endovascular therapies. Two patients presented with acute carotid blowout, and one patient with a sentinel bleed. Two patients had previously been treated with surgery and chemo radiation. One patient was treated by chemo radiation. Two had developed pharyngocutaneous fistulas, and one had an open necrosis filled wound that surrounded the carotid artery. In two patients, stent placement resolved the acute hemorrhage. In one patient, superselective embolization was done. Mean duration follow-up was 10.2 months. No patient had residual sequelae of stenting or embolization. Management of carotid blow syndrome is very critical and difficult. A multidisciplinary approach is very important in the management of carotid blow syndrome. Correct and suitable management can be life saving. An endovascular technique is a good and effective alternative with much lower morbidity rates than surgical repair or ligation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Rapid development of thymic neuroendocrine carcinoma despite transcervical thymectomy in a patient with multiple endocrine neoplasia type 1

    Directory of Open Access Journals (Sweden)

    Dhalapathy Sadacharan

    2013-01-01

    Full Text Available Thymic neuroendocrine (NE tumors are a rare manifestation of multiple endocrine neoplasia syndrome type 1 (MEN-1. They are malignant and aggressive tumors and form a major cause of mortality in MEN-1. Transcervical thymectomy (TCT at the time of parathyroid surgery for primary hyperparathyroidism (PHPT in MEN-1 usually prevents thymic NE tumors. We report a 56-year-old nonsmoker male with sporadic MEN-1 who presented with thymic NE carcinoma developing rapidly within a span of 8 months after subtotal parathyroidectomy and TCT for PHPT. We present a brief review of literature on this rare NE malignancy, focusing on its occurrence despite TCT. This case highlights the fact that thymic NE carcinoma may develop even after TCT in MEN-1. Regular surveillance for these aggressive thymic NE tumors is mandatory even after TCT in MEN-1 setting.

  2. Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study

    International Nuclear Information System (INIS)

    Hans, F.J.; Thiex, R.; Gilsbach, J.M.; Krings, T.; Moeller-Hartmann, W.; Dreeskamp, H.; Stein, K.P.; Meetz, A.; Thron, A.; Pfeffer, J.; Scherer, K.; Brunn, A.

    2003-01-01

    Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms. (orig.)

  3. Contemporary medical therapies of atherosclerotic carotid artery disease.

    Science.gov (United States)

    Cheng, Suk F; Brown, Martin M

    2017-03-01

    carotid revascularization may no longer be necessary in many of the patients in whom carotid surgery or stenting is currently performed. Two large ongoing trials are therefore comparing the risks and benefits of carotid revascularization versus intensive medical therapy alone. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Duplex evaluation following femoropopliteal angioplasty and stenting: criteria and utility of surveillance.

    Science.gov (United States)

    Baril, Donald T; Marone, Luke K

    2012-07-01

    Surveillance following lower extremity bypass, carotid endarterectomy, and endovascular aortic aneurysm repair has become the standard of care at most institutions. Conversely, surveillance following lower extremity endovascular interventions is performed somewhat sporadically in part because the duplex criteria for recurrent stenoses have been ill defined. It appears that duplex surveillance after peripheral endovascular interventions, as with conventional bypass, is beneficial in identifying recurrent lesions which may preclude failure and occlusion. In-stent stenosis following superficial femoral artery angioplasty and stenting can be predicted by both peak systolic velocity and velocity ratio data as measured by duplex ultrasound. Duplex criteria have been defined to determine both ≥50% in-stent stenosis and ≥80% in-stent stenosis. Although not yet well studied, it appears that applying these criteria during routine surveillance may assist in preventing failure of endovascular interventions.

  5. Clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting

    Directory of Open Access Journals (Sweden)

    Xiang-yu CAO

    2016-12-01

    Full Text Available Objective To explore the clinical significance of balloon dilatation angiography during cerebral venous sinus stenosis stenting to predict the reflux of perforator veins after operation. Methods A total of 93 patients (including 51 with cerebral venous sinus stenosis and intracranial hypertension and 42 with intractable pulsatile tinnitus caused by cerebral venous sinus stenosis who were treated by stent implantation were analyzed retrospectively. Among those patients, the diameter of transverse and sigmoid sinuses of 63 cases were measured based on angiography, and stent was selected according to the measurement result. The other 30 cases were given angiography on ipsilateral carotid artery or vertebral artery when the balloon was dilated in the venous sinus to confirm the reflux of perforator veins. If the venous reflux decreased in the angiography, stent with diameter 1-2 mm less than that of venous sinus could be selected.  Results The success rate of stenting was 100% (93/93. In 63 cases, 45 cases were planted 9 mm × 40 mm stents, 15 were planted 8 mm × 40 mm stents, 3 were planted 7 mm × 40 mm stents. The average diameter of stents was (8.67 ± 0.68 mm. There were 11 cases (17.46% with slow perforator venous reflux after operation. In the other 30 cases, 3 cases were planted 8 mm × 40 mm stents, 11 were planted 7 mm × 40 mm stents, and 16 were planted 6 mm × 40 mm stents. The average diameter of stents was (7.57 ± 0.67 mm. There was only one case (3.33% with slow perforator venous reflux after operation. The difference of stent diameter between 2 groups was statistically significant (t = 15.632, P = 0.001. The occurrence rate of perforator vein occlusion after operation between 2 groups was significantly different (adjusted χ 2 = 60.065, P = 0.001.  Conclusions Perforator vein occlusion after cerebral venous sinus stenting is common complication. Balloon dilatation angiography could predict the possibility of perforator vein

  6. Surgical construction of a novel simulated carotid siphon in canines

    International Nuclear Information System (INIS)

    Tan Huaqiao; Li Minghua; Zhu Yueqi; Fang Chun; Wang Jue; Wu Chungen; Cheng Yingsheng; Xie Jian; Zhang He

    2008-01-01

    Objective: To develop in vivo carotid siphon models by surgical method using the shaped devices for testing the performance of covered stent specially designed for intracranial vascular diseases. Methods: Six carotid siphon-shaped devices were established using stereolithographic biomodeling and the lost-wax technique. Six canines underwent surgery to expose and isolate bilateral CCA. The right CCA origin was ligated and incised distal to the ligation point after the distal right CCA was temporarily closed. The distal left CCA was ligated and incised proximal to the ligation point after the left CCA origin was closed. The proximal isolated left CCA was passed through the shaped device. The distal isolated right CCA and the proximal isolated left CCA were anastomosed end-to-end. Finally, the shaped device of carotid siphon was fixed with suture and embedded in the left neck. The intraarterial DSA was performed on postprocedural 7 days, 2 weeks and 1 month. The morphological characteristics of carotid siphon models were visually evaluated by two observers. The patency of siphon model and the stenosis of anastomotic stoma were followed-up. Results: All animals tolerated the surgical procedure well with mean model time construction of 90 minutes. The morphological characteristics of siphon models were similar to those in human. The anastomotic stoma stenosis occurred in 2 siphon models, and thrombosis of anastomotic stoma in 1, but all siphons of these models were patent on post-procedural follow-up angiography. Conclusion: Surgical construction of an in vivo carotid siphon model of canine with shaped device is practically feasible. This model can be used for testing neurovascular devices. (authors)

  7. StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

    OpenAIRE

    Cura, Fernando; Albertal, Mariano; Candiello, Alfonsina; Nau, Gerardo; Bonvini, Victor; Tricherri, Hernan; Padilla, Lucio T.; Belardi, Jorge A.

    2013-01-01

    Introduction Inadequate stent implantation is associated with stent thrombosis and restenosis. StentBoost can enhance stent visualization and evaluate stent expansion. Currently, there are limited comparison studies between StentBoost and intravascular ultrasound (IVUS). We aimed to test the correlation and agreement between IVUS and StentBoost measurements. Methods From December 2010 to December 2011, 38 patients (54 stents) were analyzed using IVUS and StentBoost. Minimal stent diameter and...

  8. Predictors of early stent occlusion among plastic biliary stents.

    Science.gov (United States)

    Khashab, Mouen A; Kim, Katherine; Hutfless, Susan; Lennon, Anne Marie; Kalloo, Anthony N; Singh, Vikesh K

    2012-09-01

    A major disadvantage of plastic biliary stents is their short patency rates. The aim of this study was to identify predictors of early stent occlusion among patients receiving conventional plastic biliary stents. Early stent occlusion was defined as worsening cholestatic liver test results of a severity sufficiently significant to warrant ERCP with stent exchange prior to the planned stent exchange, or as symptoms of cholangitis. The association of cumulative stent diameter, demographics, stricture location, procedure indication, Charlson comorbidity index, history of prior early stent occlusion, presence of gallbladder, and performance of sphincteromy with the occurrence of early stent occlusion was studied using logistic regression and multivariate analysis. Our patient cohort comprised 343 patients (mean age 59.3 years) who underwent 561 ERCP procedures with the placement of one or more plastic biliary stents (mean number of stents per procedure 1.2, mean total diameter of stents per procedure 12 Fr). Early stent occlusion occurred in 73 (13 %) procedures. Female gender was protective against early stent occlusion (adjusted OR 0.54, 95 % CI 0.32-0.90, p = 0.02), while hilar stricture location was independently associated with a significantly increased risk of early stent occlusion (adjusted OR 3.41, 95 % CI 1.68-6.90, p = 0.0007). Early occlusion of conventional biliary stents occurred in 13 % of cases. While female gender decreased the risk of early stent occlusion, hilar stricture location was a significant predictor of early stent occlusion. Our results suggest that physicians should consider early elective stent exchange in patients with hilar strictures.

  9. Extracranial Internal Carotid Artery Aneurysms: Report of a Ruptured Case and Review of the Literature

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Mastronikolis, Nikos; Zabakis, Peter; Kraniotis, Pantelis

    2004-01-01

    Aneurysms of the extracranial carotid arteries (ECAA) are extremely rare. Schechter et al. documented 835 cases in the literature up to 1977. One hundred and sixteen cases of ECAA have been documented in the Chinese literature since 1981, suggesting a higher prevalence of carotid aneurysmal disease in China than in the West. Four percent of all peripheral artery aneurysms are reported to be ECAA. Those arising from the internal carotid artery (EICAA) are even more rare. Two recent reviews reported 24 and 25 cases of EICAA during 21 and 17 years, respectively, the majority of them is treated surgically. Our literature review revealed only a few true EICAA managed endovascularly, but none of them with a covered stent. We describe a rare such case of ruptured atherosclerotic EICAA which was treated percutaneously

  10. Spectral Imaging for Intracranial Stents and Stent Lumen.

    Science.gov (United States)

    Weng, Chi-Lun; Tseng, Ying-Chi; Chen, David Yen-Ting; Chen, Chi-Jen; Hsu, Hui-Ling

    2016-01-01

    Application of computed tomography for monitoring intracranial stents is limited because of stent-related artifacts. Our purpose was to evaluate the effect of gemstone spectral imaging on the intracranial stent and stent lumen. In vitro, we scanned Enterprise stent phantom and a stent-cheese complex using the gemstone spectral imaging protocol. Follow-up gemstone spectral images of 15 consecutive patients with placement of Enterprise from January 2013 to September 2014 were also retrospectively reviewed. We used 70-keV, 140-keV, iodine (water), iodine (calcium), and iodine (hydroxyapatite) images to evaluate their effect on the intracranial stent and stent lumen. Two regions of interest were individually placed in stent lumen and adjacent brain tissue. Contrast-to-noise ratio was measured to determine image quality. The maximal diameter of stent markers was also measured to evaluate stent-related artifact. Two radiologists independently graded the visibility of the lumen at the maker location by using a 4-point scale. The mean of grading score, contrast/noise ratio and maximal diameter of stent markers were compared among all modes. All results were analyzed by SPSS version 20. In vitro, iodine (water) images decreased metallic artifact of stent makers to the greatest degree. The most areas of cheese were observed on iodine (water) images. In vivo, iodine (water) images had the smallest average diameter of stent markers (0.33 ± 0.17mm; P stent lumen (160.03 ±37.79; P stent-related artifacts of Enterprise and enhance contrast of in-stent lumen. Spectral imaging may be considered a noninvasive modality for following-up patients with in-stent stenosis.

  11. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  12. A Case of Complete Recovery of Fluctuating Monocular Blindness Following Endovascular Treatment in Internal Carotid Artery Dissection.

    Science.gov (United States)

    Kim, Ki-Tae; Baik, Seung Guk; Park, Kyung-Pil; Park, Min-Gyu

    2015-09-01

    Monocular blindness may appear as the first symptom of internal carotid artery dissection (ICAD). However, there have been no reports that monocular visual loss repeatedly occurs and disappears in response to postural change in ICAD. A 33-year-old woman presented with transient monocular blindness (TMB) following acute-onset headache. TMB repeatedly occurred in response to postural change. Two days later, she experienced transient dysarthria and right hemiparesis in upright position. Pupil size and light reflex were normal, but a relative afferent pupillary defect was positive in the left eye. Diffusion-weighted imaging showed no acute lesion, but perfusion-weighted imaging showed perfusion delay in the left ICA territory. Digital subtraction angiography demonstrated a false lumen and an intraluminal filling defect in proximal segment of the left ICA. Carotid stenting was performed urgently. After carotid stenting, left relative afferent pupillary defect disappeared and TMB was not provoked anymore by upright posture. At discharge, left visual acuity was completely normalized. Because fluctuating visual symptoms in the ICAD may be associated with hemodynamically unstable status, assessment of the perfusion status should be done quickly. Carotid stenting may be helpful to improve the fluctuating visual symptoms and hemodynamically unstable status in selected patient with the ICAD. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  13. Treatment of intracranial stenoses using the Neuroform stent system: initial experience in five cases

    International Nuclear Information System (INIS)

    Haehnel, Stefan; Hartmann, Marius; Ringleb, Peter

    2006-01-01

    We assessed the technical feasibility of balloon-assisted angioplasty with consecutive stenting using a flexible, self-expanding neurovascular stent for the treatment of intracranial arteriosclerotic vascular stenoses. Five consecutive patients with symptomatic drug-resistant stenoses of the intracranial internal carotid artery (ICA) or the main stem of the middle cerebral artery (MCA) were treated by balloon-assisted angioplasty with consecutive stenting using the Neuroform stent system. Balloon dilatation of the stenoses and consecutive stent placement with complete coverage of the stenoses was feasible in all patients. One patient suffered acute thrombosis distally to the stented vessel segment which was successfully treated by fibrinolysis, and one patient suffered acute subarachnoid and parenchymal hemorrhage probably due to vessel perforation. In the other three patients, no complications occurred during or immediately after angioplasty. All patients were free of further ischemic events up to the 6-month follow-up. Our findings demonstrate that the Neuroform stent system can used successfully for the treatment of intracranial stenoses of the ICA and the main stem of the MCA. Although immediate angiographic results are promising, long-term angiographic and clinical follow-up is essential to demonstrate long-term outcome. (orig.)

  14. Abciximab in the treatment of acute in-stent thrombosis in patient with intracranial aneurysm

    International Nuclear Information System (INIS)

    Lilov, M.; Juszkat, R.; Petkov, A.; Todorov, I.

    2009-01-01

    A case of endovascular therapy via embolization of aneurysm in patient with SAH is performed selective brain angiography and find 3 aneurysms. The first is in right segment M1-M2 with diameter 5 mm, the second with wide neck is in supraclinoid portion of right internal carotid artery and the third in left M1-M2 segment. One month after embolization of ruptured aneurysm with coils BALT (Montmorency, France) and previous anticoagulation therapy was applied Leo stent (SALT) intraluminal in left internal carotid artery. Developed acute instent thrombosis recanalized with intraarterial use of abciximab. (authors)

  15. Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)

    DEFF Research Database (Denmark)

    Kosonen, Petteri; Vikman, Saila; Jensen, Lisette Okkels

    2012-01-01

    This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST...... is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial....

  16. A Novel Carotid Device for Embolic Diversion: Lessons Learned from a “First in Man” Trial in Patients with Atrial Fibrillation

    International Nuclear Information System (INIS)

    Sievert, Horst; Franke, Jennifer; Grad, Ygael; Nishri, Boaz; Assaf, Yaron; Yodfat, Ofer; Römer, Albrecht; Robertson, Greg C.; Stone, Gregg W.

    2012-01-01

    Purpose: This study was designed to investigate a novel device that was developed to direct emboli away from the internal carotid artery to the external carotid artery to prevent embolic stroke while avoiding the necessity for anticoagulation with warfarin. Methods: A stent-like, self-expandable filter was developed consisting of fine cobalt alloy mesh. After promising preclinical animal testing, the device was implanted into the common carotid artery extending into the external carotid artery in three patients with atrial fibrillation, each of whom were at high-risk for cerebral emboli and were suboptimal candidates for anticoagulation. Follow-up was performed clinically and with carotid duplex ultrasound. Results: The implantation was successful in all three patients. Unrestricted flow through the filter was demonstrated in each patient at 6 months by duplex sonography. However, at 7 months ultrasound demonstrated occlusion of the internal carotid artery filter in one patient, which was subsequently confirmed by angiography. Subtotal filter occlusion occurred in a second patient at 14 months. Neither patient had clinical symptoms. Both internal carotid arteries were successfully recanalized using standard angioplasty techniques without complication. The third patient had completely normal carotid blood flow at 29 months follow-up. Conclusions: Implantation of a novel device intended to divert emboli away from the internal carotid artery was feasible, but resulted in occlusive neointimal proliferation in two of three patients. These results demonstrate a discrepancy from the findings of preclinical animal studies and human investigation.

  17. Percutaneous placement of ureteral stent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Hyup; Park, Jae Hyung; Han, Joon Koo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    Antegrade placement of ureteral stents has successfully achieved in 41 of 46 ureters. When it was difficult to advance ureteral stents through the lesion, it was facilitated by retrograde guide-wire snare technique through urethra. Complications associated with the procedure were non-function of ureteral stent by occlusion, upward migration,and spontaneous fracture of ureteral stent. These complications were managed by percutaneous nephrostomy and removal of ureteral stents by guide-wire snare technique and insertion of a new ureteral stent. While blood cell in urine was markedly increased in about 50% of patients following the procedure.

  18. Delayed pan-hypopituitarism as a complication following endovascular treatment of bilateral internal carotid artery aneurysms. A case report and review.

    Science.gov (United States)

    Hall, Jonathan; Caputo, Carmela; Chung, Carlos; Holt, Michael; Wang, Yi Yuen

    2015-04-01

    Pan-hypopituitarism has been reported in patients who are subsequently found to have a cerebral aneurysm and there have been reports of pituitary dysfunction immediately following both surgical and endovascular treatment. The authors report a rare case of delayed pan-hypopituitarism following endovascular treatment of bilateral internal carotid artery aneurysms with coil embolisation and flow-diverting stents.

  19. Carotid artery stenting versus no stenting assisting thrombectomy for acute ischaemic stroke

    DEFF Research Database (Denmark)

    Steglich-Arnholm, Henrik; Holtmannspötter, Markus; Gluud, Christian

    2016-01-01

    , company homepages, reference lists, conference proceedings, and the Science Citation Index cited reference search index will be conducted. Manufacturers of relevant interventional equipment, authors, colleagues, and researchers active in the field will be contacted. No language restrictions...

  20. Drug-eluting stents to prevent stent thrombosis and restenosis.

    Science.gov (United States)

    Im, Eui; Hong, Myeong-Ki

    2016-01-01

    Although first-generation drug-eluting stents (DES) have significantly reduced the risk of in-stent restenosis, they have also increased the long-term risk of stent thrombosis. This safety concern directly triggered the development of new generation DES, with innovations in stent platforms, polymers, and anti-proliferative drugs. Stent platform materials have evolved from stainless steel to cobalt or platinum-chromium alloys with an improved strut design. Drug-carrying polymers have become biocompatible or biodegradable and even polymer-free DES were introduced. New limus-family drugs (such as everolimus, zotarolimus or biolimus) were adopted to enhance stent performances. As a result, these new DES demonstrated superior vascular healing responses on intracoronary imaging studies and lower stent thrombotic events in actual patients. Recently, fully-bioresorbable stents (scaffolds) have been introduced, and expanding their applications. In this article, the important concepts and clinical results of new generation DES and bioresorbable scaffolds are described.

  1. Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils in a canine model

    International Nuclear Information System (INIS)

    Liu Jianmin; Zhang Xin; Zhou Xiaoping; Hong Bo; Xu Yi; Huang Qinghai; Zhang Long; She Jiagui; Zhao Rui

    2004-01-01

    Objective: To assess hemodynamics and histology of the aneurysms by treating experimental wide-necked aneurysms endovascularly with a combination of stents and electrolytic detachable coils. Methods: An experimental model was surgically constructed in the necks of six canines for simulating intracranial wide-necked aneurysms. Balloon-expandable metal stents were positioned across the aneurysms in bilateral carotid arteries of six canines with additional intraaneurysmal placement of detachable microcoils in only unilateral carotid artery of each canine. Sonography and angiography were performed in different stages and histologic examinations were achieved finally. Results: Stent placement was successful in all six canines. Aneurysms treated with only stents placement showed no significant thrombus formation with slow growing of neointima over the neck of the aneurysm. Thrombosis occurred in the aneurysms treated with stents and coils in a short time and neointima covered the neck of the aneurysms completely. Conclusions: Endovascular treatment of wide-necked aneurysms using stents combined with electrolytic detachable coils may prevent re-rupture of the aneurysms and promote neointima formation over the neck of the aneurysms. (authors)

  2. Combined stent implantation and embolization with liquid 2-polyhydroxyethyl methacrylate for treatment of experimental canine wide-necked aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Klisch, J.; Zitt, J.; Schumacher, M. [Section of Neuroradiology, University of Freiburg (Germany); Schellhammer, F. [Department of Radiology, University of Cologne, Cologne (Germany); Scheufler, K.M. [Department of Neurosurgery, University of Freiburg (Germany); Pagenstecher, A. [Department of Neuropathology, University of Freiburg, Freiburg (Germany); Nagursky, H. [Department of Oral and Maxillofacial Surgery, University of Freiburg, Freiburg (Germany)

    2002-06-01

    The purpose of the study was the evaluation of 2-polyhydroxyethyl methacrylate (2-P-HEMA) for endovascular liquid embolization of experimental side-wall aneurysms following stent protection in a canine model. The swelling behaviour and polymerization characteristics of 2-P-HEMA in different solutions were investigated in vitro. Different methods for applications were tested in a latex aneurysm model under pulsatile flow conditions. Twenty broad-based carotid side-wall aneurysms were microsurgically produced in five dogs. Four weeks after surgery self-expandable nitinol stents were placed, covering the orifice of the aneurysms. 2-P-HEMA was injected via a microcatheter, which was positioned through the meshwork of the stent. Control angiography was performed immediately after treatment and after 1, 6 and 9 months. In-vivo stent placement succeeded in all but one case. Two aneurysms occluded spontaneously after stent placement. Combined embolization of 17 aneurysms using a stent and 2-P-HEMA was performed. Eleven aneurysms could be primarily completely occluded (65%). A small remaining neck was evident in six aneurysms. Efflux of 2-P-HEMA during the process of embolization was observed in seven aneurysms, due to an excess volume of 2-P-HEMA. The excessive 2-P-HEMA led to significant vessel stenosis in two cases. Two carotid arteries (three treated aneurysms) occluded after 1 month, due to insufficient anticoagulation management. Histological examination of embolized aneurysms revealed no foreign-body or inflammatory reaction. A smooth neo-intimal layer covered the stented vessel segment. Liquid embolization of side-wall aneurysms with 2-P-HEMA is technically feasible. Embolotherapy of aneurysms with liquid agents still has the risk that embolic material will exit even when it is stent-protected. To avoid this problem, stents with smaller strut diameter and/or additional balloon-protection are required. The inert 2-P-HEMA seems to be a promising agent for combining

  3. Drug eluting stents and modern stent technologies for in-stent restenosis.

    Science.gov (United States)

    Werner, Martin

    2017-08-01

    The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.

  4. Endovascular Treatment of a Carotid Dissecting Pseudoaneurysm in a Patient with Ehlers-Danlos Syndrome Type IV with Fatal Outcome

    International Nuclear Information System (INIS)

    Lim, Siok Ping; Duddy, Martin J.

    2008-01-01

    We present a patient with Ehlers-Danlos syndrome type IV (EDS IV) with a carotid dissecting pseudoaneurysm causing severe carotid stenosis. This lesion was treated endovascularly. Unfortunately, the patient died of remote vascular catastrophes (intracranial hemorrhage and abdominal aortic rupture). This unique case illustrates the perils of endovascular treatment of EDS IV patients and the need for preoperative screening for concomitant lesions. It also shows that a dissecting pseudoaneurysm can feasibly be treated with a covered stent and that closure is effective using Angioseal in patients with EDS IV

  5. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation

    DEFF Research Database (Denmark)

    Thayssen, Per; Jensen, Lisette Okkels; Lassen, Jens Flensted

    2012-01-01

    Aims: Data are limited on the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with coronary stents. We examined the prognostic impact of stent thrombosis and in-stent restenosis in patients treated with percutaneous coronary intervention (PCI). Methods and results......: All patients who underwent stent implantation from 2002 to 2005 were identified in the Western Denmark Heart Registry. The hazard ratio (HR) for death associated with stent thrombosis or in-stent restenosis was estimated with a Cox regression analysis with stent thrombosis or in-stent restenosis...... as time-dependent variables. A total of 12,277 patients were treated with stent implantation. Stent thrombosis was observed in 111 (0.9%) patients and in-stent restenosis in 503 (4.1%) patients within 12 months after the index PCI. Occurrence of stent thrombosis was associated with an increased risk...

  6. Future developments in biliary stenting

    Science.gov (United States)

    Hair, Clark D; Sejpal, Divyesh V

    2013-01-01

    Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting. PMID:23837001

  7. MR imaging of carotid webs

    International Nuclear Information System (INIS)

    Boesen, Mari E.; Eswaradass, Prasanna Venkatesan; Singh, Dilip; Mitha, Alim P.; Menon, Bijoy K.; Goyal, Mayank; Frayne, Richard

    2017-01-01

    We propose a magnetic resonance (MR) imaging protocol for the characterization of carotid web morphology, composition, and vessel wall dynamics. The purpose of this case series was to determine the feasibility of imaging carotid webs with MR imaging. Five patients diagnosed with carotid web on CT angiography were recruited to undergo a 30-min MR imaging session. MR angiography (MRA) images of the carotid artery bifurcation were acquired. Multi-contrast fast spin echo (FSE) images were acquired axially about the level of the carotid web. Two types of cardiac phase resolved sequences (cineFSE and cine phase contrast) were acquired to visualize the elasticity of the vessel wall affected by the web. Carotid webs were identified on MRA in 5/5 (100%) patients. Multi-contrast FSE revealed vessel wall thickening and cineFSE demonstrated regional changes in distensibility surrounding the webs in these patients. Our MR imaging protocol enables an in-depth evaluation of patients with carotid webs: morphology (by MRA), composition (by multi-contrast FSE), and wall dynamics (by cineFSE). (orig.)

  8. MR imaging of carotid webs

    Energy Technology Data Exchange (ETDEWEB)

    Boesen, Mari E. [University of Calgary, Department of Biomedical Engineering, Calgary (Canada); Foothills Medical Centre, Seaman Family MR Research Centre, Calgary (Canada); Eswaradass, Prasanna Venkatesan; Singh, Dilip; Mitha, Alim P.; Menon, Bijoy K. [University of Calgary, Department of Clinical Neurosciences, Calgary (Canada); Foothills Medical Centre, Calgary Stroke Program, Calgary (Canada); Goyal, Mayank [Foothills Medical Centre, Calgary Stroke Program, Calgary (Canada); University of Calgary, Department of Radiology, Calgary (Canada); Frayne, Richard [Foothills Medical Centre, Seaman Family MR Research Centre, Calgary (Canada); University of Calgary, Hotchkiss Brain Institute, Calgary (Canada)

    2017-04-15

    We propose a magnetic resonance (MR) imaging protocol for the characterization of carotid web morphology, composition, and vessel wall dynamics. The purpose of this case series was to determine the feasibility of imaging carotid webs with MR imaging. Five patients diagnosed with carotid web on CT angiography were recruited to undergo a 30-min MR imaging session. MR angiography (MRA) images of the carotid artery bifurcation were acquired. Multi-contrast fast spin echo (FSE) images were acquired axially about the level of the carotid web. Two types of cardiac phase resolved sequences (cineFSE and cine phase contrast) were acquired to visualize the elasticity of the vessel wall affected by the web. Carotid webs were identified on MRA in 5/5 (100%) patients. Multi-contrast FSE revealed vessel wall thickening and cineFSE demonstrated regional changes in distensibility surrounding the webs in these patients. Our MR imaging protocol enables an in-depth evaluation of patients with carotid webs: morphology (by MRA), composition (by multi-contrast FSE), and wall dynamics (by cineFSE). (orig.)

  9. Plaque Characteristics of Patients with Symptomatic Mild Carotid Artery Stenosis.

    Science.gov (United States)

    Takai, Hiroki; Uemura, Juniti; Yagita, Yoshiki; Ogawa, Yukari; Kinoshita, Keita; Hirai, Satoshi; Ishihara, Manabu; Hara, Keijirou; Toi, Hiroyuki; Matsubara, Shunji; Nishimura, Hirotake; Uno, Masaaki

    2018-03-20

    Carotid revascularization may be considered for severe stenosis, but its use for symptomatic mild stenosis (<50%) with vulnerable plaque or ulcer remains uncertain. The characteristics of patients with symptomatic mild stenosis who underwent revascularization are reviewed. The subjects of this study were 18 patients with symptomatic mild stenosis (<50%) on angiography from among 175 patients who underwent revascularization in our department. The plaques were evaluated by black-blood magnetic resonance imaging (BB-MRI) and ultrasonography (US) and classified into 2 types: type 1 (n = 15), a lesion with an ulcer or mobile plaque or thrombosis on angiography or US; and type 2 (n = 3), a lesion without any of the above. Fourteen patients underwent carotid endarterectomy (CEA), and 4 patients underwent carotid artery stenting. The stenosis on angiography was 27.2% ± 10.7 (5%-41%), and the area carotid artery stenosis rate on US was 69.8 ± 14.5% (44.5%-97%). The stenosis rate of these 2 methods was not at all correlated. In type 1 plaque that underwent CEA, 10 of 11 patients had vulnerable plaque by histopathology, and 1 patient had thrombus on the plaque by operative findings. In type 2 plaque that underwent CEA, all patients had vulnerable plaque by histopathology. During the follow-up period, none of the patients had restenosis or stroke. The findings of US and BB-MRI in patients with symptomatic mild stenosis (<50%) on angiography are important for determining treatment. If BB-MRI or US shows the findings of vulnerable plaque in mild stenosis, surgical treatment may be considered for these patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  10. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  11. Carotid Surgery in a District General Hospital

    Science.gov (United States)

    Fairgrieve, John

    1981-01-01

    The carotid surgical experience of Cheltenham General Hospital over a 13 year period (1968-81) is presented. This includes 42 operations for stenosis, and 12 further operations for carotid body tumour, carotid aneurysm, subclavian steal syndrome and trauma to the internal carotid artery. The operative techniques and complications are briefly discussed and reasons advanced for a more agressive approach to the problems of extra-cerebral carotid disease in this country. PMID:7185417

  12. Future developments in biliary stenting

    Directory of Open Access Journals (Sweden)

    Hair CD

    2013-06-01

    Full Text Available Clark D Hair,1 Divyesh V Sejpal21Department of Medicine, Section of Gastroenterology and Hepatology, Baylor College of Medicine, Houston, TX, USA; 2Department of Medicine, Section of Gastroenterology, Hofstra North Shore-LIJ School of Medicine, North Shore University Hospital, Manhasset, NY, USAAbstract: Biliary stenting has evolved dramatically over the past 30 years. Advancements in stent design have led to prolonged patency and improved efficacy. However, biliary stenting is still affected by occlusion, migration, anatomical difficulties, and the need for repeat procedures. Multiple novel plastic biliary stent designs have recently been introduced with the primary goals of reduced migration and improved ease of placement. Self-expandable bioabsorbable stents are currently being investigated in animal models. Although not US Food and Drug Administration approved for benign disease, fully covered self-expandable metal stents are increasingly being used in a variety of benign biliary conditions. In malignant disease, developments are being made to improve ease of placement and stent patency for both hilar and distal biliary strictures. The purpose of this review is to describe recent developments and future directions of biliary stenting.Keywords: plastic stents, self-expandable metal stents, drug eluting stents, bioabsorbable stents, malignant biliary strictures, benign biliary strictures

  13. Transcervical Embryo recovery by transcervical technique in ...

    African Journals Online (AJOL)

    Vicente Freitas

    every four hours for as long as they exhibited standing oestrus. ... both techniques was inspected under a stereomicroscope (Nikon, Japan) at a magnification of 40-70x to ... to that cited by other researchers working on superovulation of goats.

  14. Contemporary Management of Patients with Concomitant Coronary and Carotid Artery Disease.

    Science.gov (United States)

    Poi, Mun J; Echeverria, Angela; Lin, Peter H

    2018-01-01

    The ideal management of concomitant carotid and coronary artery occlusive disease remains elusive. Although researchers have advocated the potential benefits of varying treatment strategies based on either concomitant or staged surgical treatment, there is no consensus in treatment guidelines among national or international clinical societies. Clinical studies show that coronary artery bypass grafting (CABG) with either staged or synchronous carotid endarterectomy (CEA) is associated with a high procedural stroke or death rate. Recent clinical studies have found carotid artery stenting (CAS) prior to CABG can lead to superior treatment outcomes in asymptomatic patients who are deemed high risk of CEA. With emerging data suggesting favorable outcome of CAS compared to CEA in patients with critical coronary artery disease, physicians must consider these diverging therapeutic options when treating patients with concurrent carotid and coronary disease. This review examines the available clinical data on therapeutic strategies in patients with concomitant carotid and coronary artery disease. A treatment paradigm for considering CAS or CEA as well as CABG and percutaneous coronary intervention is discussed.

  15. Endovascular stent-support angioplasty for cerebral venous sinus stenosis

    Directory of Open Access Journals (Sweden)

    Xin-feng LI

    2011-06-01

    Full Text Available Objective To investigate the pathophysiological features of cerebral venous sinus stenosis,and the modus and therapeutic effect of stent-support angioplasty.Methods The clinical data of 36 patients with cerebral venous sinus stenosis,admitted to Neurosurgical Department of General Hospital of PLA from Dec.2001 to Jun.2010,were retrospectively analyzed.Of the 36 cases,10 were males and 26 females,aged from 14 to 57 years with a mean of 37.8 years,and the disease course ranged from 4 days to 9 years.The main clinical manifestations included headache,vomiting,optical visual blurring,and limb weakness with anesthesia in some patients.The diagnosis of all patients was confirmed by digital subtraction angiography,and the results showed that the local stenosis located in right transverse-sigmoid sinus in 21 cases,left transverse-sigmoid sinus in 12 cases,and on both sides in 3 cases.All patients received thrombolytic therapy via carotid artery or a microcatheter inserted in the venous sinus,followed by stent angioplasty of venous sinus.Meanwhile,general anticoagulant and antiplatelet therapy were essential.Results All the 36 patients were successively treated with balloon dilatation and stent angioplasty of venous sinus with exception of 3 cases,who failed because of the circuitous jugular foramen preventing the insertion of the stent.The successful rate was 91.7%.The cerebrospinal fluid pressure of the patients was lowered from 374.7±82.9mmH2O before operation to 230.3±48.1mmH2O after operation.Thirty-three patients were followed-up for 1 month to 8 years by brain angiography and examinations in the outpatient clinic.Among them 32 showed persistent relief of clinical symptoms.The remaining patient presented severe headache and optical visual blurring 1 month after stent implantation,however the symptoms were alleviated obviously after thrombolytic therapy via the carotid artery with adequate anticoagulation.Conclusions Stent angioplasty of venous

  16. Heterogeneous Intravascular Ultrasound Findings of Stent Thrombosis

    OpenAIRE

    Morofuji, Toru; Inaba, Shinji; Aisu, Hiroe; Takahashi, Kayo; Saito, Makoto; Higashi, Haruhiko; Yoshii, Toyofumi; Sumimoto, Takumi

    2017-01-01

    Objective The underlying mechanisms of stent thrombosis are not completely understood. Methods We experienced 12 definite stent thrombosis cases (1 early, 1 late, and 10 very late) at our hospital from July 2011 to April 2016 and evaluated the possible causes of stent thrombosis by intravascular ultrasound (IVUS). Results Five different potential morphological causes of stent thrombosis (neoatherosclerosis, stent malapposition, stent fracture, edge dissection, and stent underexpansion) were d...

  17. What Is Carotid Artery Disease?

    Science.gov (United States)

    ... Lack of physical activity . Too much sitting (sedentary lifestyle) and a lack of aerobic activity can worsen other risk factors for carotid artery disease, such as unhealthy blood cholesterol levels, high blood pressure, diabetes, and ...

  18. Intracerebral haemorrhage after carotid endarterectomy

    DEFF Research Database (Denmark)

    Schroeder, T; Sillesen, H; Boesen, J

    1987-01-01

    Among 662 consecutive carotid endarterectomies eight cases of postoperative ipsilateral intracerebral haemorrhage were identified, occurring into brain areas which, preoperatively were without infarction. As blood pressures across the stenosis were routinely measured during surgery, the internal...

  19. Treatment of a cervical carotid pseudoaneurysm that occurred years after laryngectomy and irradiation of a neck tumor. Case report

    International Nuclear Information System (INIS)

    Hanakita, Shunya; Iijima, Akira; Ishikawa, Osamu; Kamada, Kyousuke; Saito, Nobuhito

    2011-01-01

    A 62-year-old man presented with rupture of a pseudoaneurysm of the left common carotid artery (CCA) that was induced after radiation therapy and neck surgery. The initial treatment was an endovascular procedure to obliterate the aneurysm with coils, and a covered stent was placed in the parent artery. However, the patient presented with subsequent coil migration, wound infection, and left CCA stenosis. Direct surgical procedures were then performed, including resection of the pseudoaneurysm with coils and stent; replacement of the carotid artery with a saphenous vein graft; and operative wound reinforcement with a pedicle flap. Endovascular treatments may be chosen for vascular diseases after irradiation, because of the low risk of wound infection and fragility of the vessels, but the long-term outcomes of intravascular treatments are still unclear. In direct surgery, dissection of the adhesive tissue and adequate wound healing are difficult. Musculocutaneous flaps with vascular pedicles can achieve good results. (author)

  20. Effect of transcervical resection of adhesion combined with low-dose aspirin on uterine artery blood flow and Smad2/3 in endometrial tissue

    Directory of Open Access Journals (Sweden)

    Qian-Wen Chen

    2016-11-01

    Full Text Available Objective: To study the effect of transcervical resection of adhesion combined with lowdose aspirin on uterine artery blood flow and Smad2/3 in endometrial tissue. Methods: A total of 78 patients with severe intrauterine adhesions who received transcervical resection of adhesion in our hospital between June 2012 and October 2014 were prospectively studied and randomly divided into two groups, observation group received postoperative estrogenprogestogen combined with low-dose aspirin therapy, and control group received postoperative estrogen-progestogen therapy. Ultrasound examination was conducted before and after treatment to determine uterine artery and endometrial blood flow parameters, intrauterine adhesion tissue was collected to detect the expression levels of Smad2 and Smad3 as well as downstream molecules, and serum was collected to determine the levels of cytokines. Results: On the ovulation day after 3 cycles of treatment, uterine artery RI and PI of observation group were significantly lower than those of control group, and endometrial VI, FI and VFI were significantly higher than those of control group; uPA expression level in intrauterine adhesion tissue of observation group was significantly higher than that of control group, Smad2, Smad3, PAI-1, ADAM15 and ADAM17 expression levels were significantly lower than those of control group, and serum TGF-β, VEGF, CTGF, IGF-I and TNF-α levels were significantly lower than those of control group. Conclusions: Transcervical resection of adhesion combined with low-dose aspirin therapy can improve the postoperative uterine artery and endometrial blood flow state, inhibit extracellular matrix deposition mediated by Smad2/3 signaling pathway and prevent intrauterine re-adhesion in patients with intrauterine adhesions.

  1. Endovascular treatment in proximal and intracranial carotid occlusion 9 hours after symptom onset

    International Nuclear Information System (INIS)

    Jakubowska, Malgorzata M.; Michels, Peter; Mueller-Jensen, Axel; Leppien, Andreas; Eckert, Bernd

    2008-01-01

    A debate is emerging over whether the treatment time window in acute stroke can be extended beyond 6 h if penumbral tissue can be identified. Treatment decisions are very difficult in cases of tandem proximal carotid occlusion with arterioarterial intracranial embolism. We enter this debate with the present report on a case of atherosclerotic proximal carotid occlusion and resulting periocclusional carotid T embolism that was successfully treated 9 h after symptom onset. The case of a 68-year-old man with fluctuating symptoms of right-hemispheric stroke is presented (NIHSS score 12-20 on admission). CT angiography demonstrated proximal carotid occlusion and periocclusional embolism of the entire internal carotid artery (ICA) including the carotid T segment. Penumbral tissue was diagnosed by nonenhanced and perfusion CT imaging 7.5 h after symptom onset. Treatment was initiated 9 h after symptom onset by passing the proximal occlusion with a microcatheter and local administration of recombinant tissue plasminogen activator (rt-PA) into the carotid T segment at the level of posterior communicating artery (PCoA) origin. Recanalization of the ICA and middle cerebral artery was accomplished within 1 h by flow establishment via the PCoA. The atherosclerotic proximal ICA occlusion was not stented due to the risk of embolism from remnant thrombi in the petrous and cavernous ICA segments. Follow-up MRI showed only mild haemorrhagic infarct transformation of the initial infarct core. The patient was discharged from hospital 18 days after treatment with NIHSS score 5. If penumbral tissue can be conclusively identified, endovascular treatment in proximal and intracranial tandem occlusion can be successful, even in treatments initiated 6-9 h after stroke onset. If the intracranial flow after recanalization can be established via the circle of Willis, the underlying proximal ICA occlusion may not require treatment. (orig.)

  2. Endovascular treatment in proximal and intracranial carotid occlusion 9 hours after symptom onset

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowska, Malgorzata M.; Michels, Peter; Mueller-Jensen, Axel [Asklepios Clinic Altona, Department of Neurology, Hamburg (Germany); Leppien, Andreas; Eckert, Bernd [Asklepios Clinic Altona, Department of Neuroradiology, Hamburg (Germany)

    2008-07-15

    A debate is emerging over whether the treatment time window in acute stroke can be extended beyond 6 h if penumbral tissue can be identified. Treatment decisions are very difficult in cases of tandem proximal carotid occlusion with arterioarterial intracranial embolism. We enter this debate with the present report on a case of atherosclerotic proximal carotid occlusion and resulting periocclusional carotid T embolism that was successfully treated 9 h after symptom onset. The case of a 68-year-old man with fluctuating symptoms of right-hemispheric stroke is presented (NIHSS score 12-20 on admission). CT angiography demonstrated proximal carotid occlusion and periocclusional embolism of the entire internal carotid artery (ICA) including the carotid T segment. Penumbral tissue was diagnosed by nonenhanced and perfusion CT imaging 7.5 h after symptom onset. Treatment was initiated 9 h after symptom onset by passing the proximal occlusion with a microcatheter and local administration of recombinant tissue plasminogen activator (rt-PA) into the carotid T segment at the level of posterior communicating artery (PCoA) origin. Recanalization of the ICA and middle cerebral artery was accomplished within 1 h by flow establishment via the PCoA. The atherosclerotic proximal ICA occlusion was not stented due to the risk of embolism from remnant thrombi in the petrous and cavernous ICA segments. Follow-up MRI showed only mild haemorrhagic infarct transformation of the initial infarct core. The patient was discharged from hospital 18 days after treatment with NIHSS score 5. If penumbral tissue can be conclusively identified, endovascular treatment in proximal and intracranial tandem occlusion can be successful, even in treatments initiated 6-9 h after stroke onset. If the intracranial flow after recanalization can be established via the circle of Willis, the underlying proximal ICA occlusion may not require treatment. (orig.)

  3. Hyperfusion syndrome after carotid endarterectomy

    International Nuclear Information System (INIS)

    Harrison, P.B.; Wong, M.J.; Belzberg, A.; Holden, J.

    1991-01-01

    This article describes the CT scans of two patients who, following carotid endarterectomy, developed headache and seizures suggestive of hyperperfusion syndrome. Their CT scans demonstrated ipsilateral mass effect and white matter hypodensity. One patient progressed to hemorrhage and died. Although infarction is described as the commonest neurologic event to occur after carotid endarterectomy, autopsy or cerebral blood flow studies in these patients suggests that the changes were due to hyperperfusion rather that infarction. (orig.)

  4. Indications and applications of arterial stents for stroke prevention in atherosclerotic intracranial stenosis.

    Science.gov (United States)

    Fields, Jeremy D; Liu, Kenneth C; Barnwell, Stanley L; Clark, Wayne M; Lutsep, Helmi L

    2010-01-01

    Intracranial stenosis accounts for 8-10% of all ischemic strokes in North America, a frequency slightly less than that of extracranial carotid stenosis. Among patients presenting with transient ischemic attack or stroke due to intracranial stenosis, the risk of recurrent stroke in the first year after initial symptoms is about 14%. Those with high-risk features (recent stroke and severe stenosis) have up to a 23% rate of recurrent stroke in the year after their initial event. Angioplasty with stenting has emerged as a potential treatment strategy, particularly in high-risk patients, although evidence is currently limited to uncontrolled prospective trials and retrospective case series. In this article, we critically review the clinical results supporting the use of stenting and highlight some key considerations in the application of this technology, including patient selection, procedural management, technical issues, and risk factors for complications and in-stent restenosis.

  5. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    Science.gov (United States)

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  6. Cardiovascular magnetic resonance in carotid atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Chen Huijun

    2009-12-01

    Full Text Available Abstract Atherosclerosis is a chronic, progressive, inflammatory disease affecting many vascular beds. Disease progression leads to acute cardiovascular events such as myocardial infarction, stroke and death. The diseased carotid alone is responsible for one third of the 700,000 new or recurrent strokes occurring yearly in the United States. Imaging plays an important role in the management of atherosclerosis, and cardiovascular magnetic resonance (CMR of the carotid vessel wall is one promising modality in the evaluation of patients with carotid atherosclerotic disease. Advances in carotid vessel wall CMR allow comprehensive assessment of morphology inside the wall, contributing substantial disease-specific information beyond luminal stenosis. Although carotid vessel wall CMR has not been widely used to screen for carotid atherosclerotic disease, many trials support its potential for this indication. This review summarizes the current state of knowledge regarding carotid vessel wall CMR and its potential clinical application for management of carotid atherosclerotic disease.

  7. Self-expandable metalic endotracheal stent

    International Nuclear Information System (INIS)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author)

  8. Self-expandable metalic endotracheal stent

    Energy Technology Data Exchange (ETDEWEB)

    Do, Young Soo; Cho, Dae Soon; Cho, Kyung Ja; Lee, Young Soo; Lee, Mi Jae [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1993-01-01

    Six bare stents and six covered stents were inserted in the trachea of 12 dogs under general anesthesia. After 1-10 weeks of observation, the dogs were killed, and the trachea and lung were examined grossly and histologically. Pneumonia and stent migration were observed more frequently at covered stent group. Inflammatory change of the trachea was more severe at covered stent group. In conclusion, we believe that it is inadequate to insert silicone covered stent in the tracheobronchial tree. (Author).

  9. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  11. Indications for stenting during thrombolysis

    DEFF Research Database (Denmark)

    Bækgaard, N; Broholm, R; Just, Sven Richardt Lundgren

    2013-01-01

    of a stent in this position is the treatment of choice facilitating the venous flow into an unobstructed outflow tract either from the femoral vein or the deep femoral vein or both. The stent, made of stainless steel or nitinol, has to be self-expandable and flexible with radial force to overcome...... the challenges in this low-pressure system. The characteristics of the anatomy with external compression and often a curved vein segment with diameter difference make stent placement necessary. Ballooning alone has no place in this area. The proportion of inserted stents varies in the published materials...

  12. The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis

    Directory of Open Access Journals (Sweden)

    Hiroshi Fujita

    2014-12-01

    Full Text Available Background: Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. Aim: We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. Methods: Sirolimus-eluting stents were implanted in 88 lesions and bare metal stents were implanted in 43 lesions. We compared stenting strategy, major adverse cardiac events, and angiographic results between sirolimus-eluting stent and bare metal stent groups. Results: Stent diameter was smaller and stent length was longer in the sirolimus-eluting stent group than in the bare metal stent group in our routine practices. There was no significant between-group difference in late diameter loss. Rates of angiographic restenosis and target lesion revascularization were significantly higher in the sirolimus-eluting stent group than in the bare metal stent group. Although stent length was significantly longer and stent diameter was smaller in the sirolimus-eluting stent group, sirolimus-eluting stents did not improve the subsequent clinical and angiographic results compared with bare metal stents in dialysis patients. Conclusion: In dialysis patients, a longer length and/or smaller diameter sirolimus-eluting stent implantation was associated with high rates of restenosis and target lesion revascularization compared with bare metal stents.

  13. Dedicated bifurcation stents

    Directory of Open Access Journals (Sweden)

    Ajith Ananthakrishna Pillai

    2012-03-01

    Full Text Available Bifurcation percutaneous coronary intervention (PCI is still a difficult call for the interventionist despite advancements in the instrumentation, technical skill and the imaging modalities. With major cardiac events relate to the side-branch (SB compromise, the concept and practice of dedicated bifurcation stents seems exciting. Several designs of such dedicated stents are currently undergoing trials. This novel concept and pristine technology offers new hope notwithstanding the fact that we need to go a long way in widespread acceptance and practice of these gadgets. Some of these designs even though looks enterprising, the mere complex delivering technique and the demanding knowledge of the exact coronary anatomy makes their routine use challenging.

  14. Carotid cavernous fistula after elective carotid endarterectomy: Case report

    Directory of Open Access Journals (Sweden)

    Andres Asser

    2014-12-01

    This is a case to illustrate a rare complication of carotid artery surgery. The patient had atherosclerotic vessel damage of ICA visible on earlier CT scans. This combined with abrupt increase of transmural pressure due to the revascularization procedure could possibly lead to arterial wall rupture and fistula formation.

  15. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  16. Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

    International Nuclear Information System (INIS)

    Struffert, Tobias; Ott, Sabine; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Doerfler, Arnd; Deuerling-Zheng, Yu

    2011-01-01

    Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents. (orig.)

  17. Treatment of Cervical Internal Carotid Artery Spontaneous Dissection with Pseudoaneurysm and Unilateral Lower Cranial Nerves Palsy by Two Silk Flow Diverters

    Energy Technology Data Exchange (ETDEWEB)

    Zelenak, Kamil, E-mail: zelenak@unm.sk [University Hospital, Department of Radiology (Slovakia); Zelenakova, Jana [University Hospital, Department of Neurology (Slovakia); DeRiggo, Julius [University Hospital, Department of Neurosurgery (Slovakia); Kurca, Egon; Kantorova, Ema [University Hospital, Department of Neurology (Slovakia); Polacek, Hubert [University Hospital, Department of Radiology (Slovakia)

    2013-08-01

    Internal carotid artery (ICA) lesions in the parapharyngeal space (a dissection and a pseudoaneurysm) may present as isolated lower cranial nerves (IX, X, XI, and XII) palsy (Collet-Sicard syndrome). Some arteriopathies such as fibromuscular dysplasia and tortuosity make a vessel predisposed to dissection. Extreme vessel tortuosity makes the treatment by a stent graft impossible. Two Silk stents were used in a 46 year-old man with left lower cranial nerves (IX-XII) palsy for the treatment of left ICA spontaneous dissection with pseudoaneurysm. A follow-up angiogram 5 months later confirmed pseudoaneurysm thrombosis and patency of the left ICA. The patient recovered completely from the deficits.

  18. Treatment of Cervical Internal Carotid Artery Spontaneous Dissection with Pseudoaneurysm and Unilateral Lower Cranial Nerves Palsy by Two Silk Flow Diverters

    International Nuclear Information System (INIS)

    Zeleňák, Kamil; Zeleňáková, Jana; DeRiggo, Július; Kurča, Egon; Kantorová, Ema; Poláček, Hubert

    2013-01-01

    Internal carotid artery (ICA) lesions in the parapharyngeal space (a dissection and a pseudoaneurysm) may present as isolated lower cranial nerves (IX, X, XI, and XII) palsy (Collet–Sicard syndrome). Some arteriopathies such as fibromuscular dysplasia and tortuosity make a vessel predisposed to dissection. Extreme vessel tortuosity makes the treatment by a stent graft impossible. Two Silk stents were used in a 46 year-old man with left lower cranial nerves (IX–XII) palsy for the treatment of left ICA spontaneous dissection with pseudoaneurysm. A follow-up angiogram 5 months later confirmed pseudoaneurysm thrombosis and patency of the left ICA. The patient recovered completely from the deficits

  19. Mechanical Stresses in Carotid Plaques

    DEFF Research Database (Denmark)

    Samuel, Samuel Alberg

    simulationer, som tillod beregning af longitudinelle stress-niveauer i den fibrøse kappe. Afhandlingen indeholder tre artikler, som beskriver denne metode. Den første; “Mechanical Stresses in Carotid Plaques using MRI-Based Fluid Structure Interaction Models”, beskriver i detaljer metoden til at danne de...

  20. Intravascular local gene transfer mediated by protein-coated metallic stent.

    Science.gov (United States)

    Yuan, J; Gao, R; Shi, R; Song, L; Tang, J; Li, Y; Tang, C; Meng, L; Yuan, W; Chen, Z

    2001-10-01

    To assess the feasibility, efficiency and selectivity of adenovirus-mediated gene transfer to local arterial wall by protein-coated metallic stent. A replication-defective recombinant adenovirus carrying the Lac Z reporter gene for nuclear-specific beta-galactosidase (Ad-beta gal) was used in this study. The coating for metallic stent was made by immersing it in a gelatin solution containing crosslinker. The coated stents were mounted on a 4.0 or 3.0 mm percutaneous transluminal coronary angioplasty (PTCA) balloon and submersed into a high-titer Ad-beta gal viral stock (2 x 10(10) pfu/ml) for 3 min, and then implanted into the carotid arteries in 4 mini-swines and into the left anterior descending branch of the coronary artery in 2 mini-swines via 8F large lumen guiding catheters. The animals were sacrificed 7 (n = 4), 14 (n = 1) and 21 (n = 1) days after implantation, respectively. The beta-galactosidase expression was assessed by X-gal staining. The results showed that the expression of transgene was detected in all animal. In 1 of carotid artery with an intact intima, the beta-gal expression was limited to endothelial cells. In vessels with denuded endothelium, gene expression was found in the sub-intima, media and adventitia. The transfection efficiency of medial smooth muscle cells was 38.6%. In 2 animals sacrificed 7 days after transfection, a microscopic examination of X-gal-stained samples did not show evidence of transfection in remote organs and arterial segments adjacent to the treated arterial site. Adenovirus-mediated arterial gene transfer to endothelial, smooth muscle cells and adventitia by protein-coated metallic stent is feasible. The transfection efficiency is higher. The coated stent may act as a good carrier of adenovirus-mediated gene transfer and have a potential to prevent restenosis following PTCA.

  1. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  2. Stent fabric fatigue of grafts supported by Z-stents versus ringed stents: an in vitro buckling test.

    Science.gov (United States)

    Lin, Jing; Wang, Lu; Guidoin, Robert; Nutley, Mark; Song, Ge; Zhang, Ze; Du, Jia; Douville, Yvan

    2014-03-01

    Stent-grafts externally fitted with a Z-shaped stents were compared to devices fitted with ringed stents in an in vitro oscillating fatigue machine at 200 cycles per minute and a pressure of 360 mmHg for scheduled durations of up to 1 week. The devices fitted with Z-stents showed a considerably lower endurance limit to buckling compared to the controls. The contact between the apexes of adjacent Z-stents resulted in significant damage to the textile scaffolds and polyester fibers due to the sharp angle of the Z-stents. The ringed stents did not cause any fraying in the textile scaffolds.

  3. Therapeutic effect of enterprise stent-assisted embolization for very small ruptured intracranial aneurysms.

    Science.gov (United States)

    Qin, Feiyun; Li, Zhenbao; Fang, Xinggen; Zhao, Xintong; Liu, Jiaqiang; Wu, Degang; Lai, Niansheng

    2017-08-01

    Enterprise stent has been widespread used in wide-necked intracranial aneurysms and good efficacy has been achieved, but there are few reports on its applications in very small ruptured intracranial aneurysms in literatures. This study aimed to evaluate the safety and efficacy of Enterprise stent-assisted coiling embolization of very small ruptured intracranial aneurysms.We retrospectively reviewed the clinical and imaging data from 37 patients with very small ruptured intracranial aneurysms who had SAC using Enterprise stents performed from February 2012 to July 2016 in our department. Data collected and analyzed included patient demographics, morphologic features of the aneurysm, treatment results, and follow-up results. Clinical outcomes were evaluated by the Glasgow Outcome Scale (GOS).Enterprise stents were successfully implanted in all 37 patients with very small ruptured intracranial aneurysms. Of the 37 individuals, 28 patients exhibited complete occlusion at Raymond grade I, 5 patients exhibited occlusion at Raymond grade II, and 4 patients at Raymond grade III. Procedure-related complications occurred in 3 of 37 patients (8.1%), including 1 case of intraprocedure aneurysm rupture who died from cerebral herniation caused by severe postoperative cerebral ischemia during the hospital stay, and the other 2 complications were acute in-stent thrombosis, and occlusion of parent artery caused by falling-off internal carotid artery plaque, respectively. A total of 36 patients underwent postoperative clinical follow-up visits for 6 to 24 months of which 31 patients recovered (GOS ≥ 4). One patient had hemiplegic paralysis, and no rehemorrhage was found. A total of 25 patients underwent follow-up digital subtraction angiography (DSA) at 3-21 months postintervention, in whom there were 22 cases with complete occlusion, 2 cases with recurrence of aneurysm neck, and 1 case with in-stent restenosis, but there was no patient with neurologic deficits.The Enterprise

  4. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    Full text: Percutaneous transhepatic cholangiography (PTC) is an X-ray or US guided procedure that involves the injection of a contrast material directly into the bile ducts inside the liver to produce pictures of them. If a blockage or narrowing is found, additional procedures may be performed: 1. insertion of a catheter to drain excess bile out of the body or both - internal and external; 2. plastic endoprothesis placement; 3. self-expandable metal stents placement to help open bile ducts or to bypass an obstruction and allow fluids to drain. Current percutaneous biliary interventions include percutaneous transhepatic cholangiography (PTC) and biliary drainage to manage benign and malignant obstructions. Internal biliary stents are either plastic or metallic, and various types of each kind are available. Internal biliary stents have several advantages. An external tube can be uncomfortable and have a psychological disadvantage. An internal stent prevents the problems related to external catheters, for example, pericatheter leakage of bile and the need for daily flushing. The disadvantages include having to perform endoscopic retrograde cholangiopancreatography (ERCP) or new PTC procedures to obtain access in case of stent obstruction. Better patency rates are reported with metallic than with plastic stents in cases of malignant obstruction, though no effect on survival is noted. Plastic internal stents are the cheapest but reportedly prone to migration. Metallic stents are generally not used in the treatment of benign disease because studies have shown poor long-term patency rates. Limited applications may include the treatment of patients who are poor surgical candidates or of those in whom surgical treatment fails. Most postoperative strictures are treated surgically, though endoscopic and (less commonly) percutaneous placement of nonmetallic stents has increasingly been used in the past few years. Now there are some reports about use of biodegradable biliary

  5. Endotracheal expandable metallic stent placement in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, S; Tanabe, Y; Fujiwara, Y; Koyama, T; Tanigawa, N; Kobayashi, M; Katsube, Y; Nakamura, H [Tottori Univ. School of Medicine, Yonago (Japan). Dept. of Radiology Research Inst. for Microbial Diseases, Osaka (Japan). Dept. of Radiology

    1991-01-01

    Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).

  6. Microembolization is associated with transient cognitive decline in patients undergoing carotid interventions.

    Science.gov (United States)

    Hitchner, Elizabeth; Baughman, Brittanie D; Soman, Salil; Long, Becky; Rosen, Allyson; Zhou, Wei

    2016-12-01

    Carotid interventions are important in helping to reduce the risk of stroke for patients with high-grade carotid artery stenosis; however, subclinical cerebral microemboli can occur during these procedures. Associations have been found between the incidence of microemboli and postoperative decline in memory. We therefore sought to determine whether this decline persisted long-term and to assess changes in other cognitive domains. Patients were prospectively recruited under an Institutional Review Board-approved protocol at a single academic center. Neuropsychological testing was administered preoperatively and at 1-month and 6-month intervals postoperatively. Cognitive domains that were evaluated included verbal memory, visual memory, psychomotor speed, dexterity, and executive function. Diffusion-weighted magnetic resonance imaging sequencing was performed preoperatively and ≤48 hours postoperatively to identify procedure-related microemboli. Univariate and multivariate regression models were used to identify relationships among microembolization, demographics, and cognition. Included were 80 male patients with an average age of 69 years. Forty patients underwent carotid artery stenting and 40 underwent carotid endarterectomy. Comorbidities included diabetes in 45%, coronary artery disease in 50%, and prior neurologic symptoms in 41%. New postoperative microemboli were found in 45 patients (56%). Microembolization was significantly more common in the carotid artery stenting cohort (P memory and Trail Making A measures. Multivariate analysis demonstrated that procedurally related embolization (odds ratio [OR], 2.8; P = .04) and preoperative symptomatic stenosis (OR, 3.2; P = .026) were independent predictors of decline for the Rey Auditory Verbal Learning Test Short Delay measure at 1 month. At 6 months, no significant relationship was found between emboli and decline on Rey Auditory Verbal Learning Test Short Delay, but age (OR, 1.1, P = .005) and

  7. Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.

    Science.gov (United States)

    Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang

    2015-10-01

    The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.

  8. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  9. Acute internal carotid artery occlusion after carotid endarterectomy

    Directory of Open Access Journals (Sweden)

    Masatoshi Yunoki

    2016-09-01

    Full Text Available We report two cases of acute carotid artery (CA occlusion following carotid endarterectomy (CEA. Case 1: a 58-year-old man was admitted with transient right-sided hemiparesis. Magnetic resonance imaging (MRI and MR angiography (MRA revealed cerebral infarction in the left cerebral hemisphere and left CA stenosis. Ten days after admission, he underwent CEA. 24 h after surgery, he developed right hemiplegia. MRI and MRA demonstrated a slightly enlarged infarction and left internal carotid artery (ICA occlusion. Emergency reoperation was performed and complete recanalization achieved. The patient made a clinically significant recovery. Case 2: a 65 year-old man underwent a right-sided CEA for an asymptomatic 80% CA stenosis. 48 h after surgery, his family noticed he was slightly disorientated. MRI and MRA revealed multiple infarctions and right ICA occlusion. He was treated with antiplatelet therapy without reoperation because sufficient cross-flow from the left ICA through the anterior communicating artery was demonstrated by angiography, and his neurological symptoms were mild. His symptoms gradually alleviated and he was discharged 14 days after surgery. With ICA occlusion after CEA, immediate re-operation is mandatory with severe neurological symptoms, whereas individualized judgement is needed when the symptoms are mild.

  10. Cosmetic effects of skin-crease camouflage incision versus longitudinal incision following carotid endarterectomy.

    Science.gov (United States)

    Kazimierczak, Arkadiusz; Rybicka, Anita; Rynio, Pawel; Gutowski, Piotr; Wiernicki, Ireneusz

    2018-03-01

    Despite the increasing use of carotid angioplasty and stenting (CAS), carotid endarterectomy (CEA) nonetheless remains a more medically beneficial method of treatment for carotid artery stenosis. Therefore, one possibility for progress within this procedure may be to use minimally invasive carotid surgery, especially when the scar is in plain sight: the use of the natural wrinkles (skin crease) as a camouflage of the skin incision provides significant cosmetic improvements. To compare the cosmetic effects of classic and trans-wrinkle CEA. To assess the distance between the carotid artery bifurcation (CAB) and the skin-crease incision whilst attempting CEA. It was a randomized prospective study with two groups: patients undergoing classic surgery (control group; n = 100) and skin-crease trans-wrinkle camouflaged CEA (study group; n = 100). Follow-up was at 2 months and 1 year. The medical results of the treatment were similar in both groups. The cumulative count of strokes and myocardial infarctions was 0.5% within 30 days, and after one year 3.5% (and 5.5% including cases of death). The superiority of the transverse crease being hidden compared to the conventional longitudinal technique was proven in the Patient and Observer Scar Assessment Scale (POSAS) score, respectively 11.4 ±1.0 vs. 14.1 ±3.4 (p = 0.0001) after 2 months and 13.5 ±2.8 vs. 14.1 ±3.4 (p = 0.039) after a year. Trans-wrinkle incision gives better cosmetic results, can be safely performed in most cases, and offers a comfortable approach during CEA.

  11. Percutaneous transluminal angioplasty of the carotid artery

    International Nuclear Information System (INIS)

    Numaguchi, Y.; Tulane Univ., New Orleans, LA; Puyau, F.A.; Provenza, L.J.; Richardson, D.E.

    1984-01-01

    The successful dilatation of postsurgical concentric stenosis of an internal carotid artery using percutaneous transluminal angioplasty (PTA) is reported here. Only one such case has been previously documented. Review of the literature disclosed 16 patients who received transluminal angioplasty for stenosis of carotid arteries by percutaneous or open arteriotomy techniques. The authors feel that PTA may be the treatment of choice for postoperative concentric stenosis of a short segment of the carotid artery as opposed to surgical repair. (orig.)

  12. A new experimental carotid siphon aneurysm model in canine based on the MR angiography and rapid prototyping technology

    International Nuclear Information System (INIS)

    Xie Jian; Li Minghua; Tan Huaqiao; Zhu Yueqi; Hu Dingjun; Qiao Ruihua; Fan Chunhua

    2009-01-01

    Objective: The aim of the experiment is to make an intracranial aneurysm model in canine. Methods: A digital tube was made based on raw magnetic resonance images of the human intracranial carotid artery. Then 6 tubes were made in the 3D rapid prototyping machine and coated with silicone. Finally we isolated the common carotid arteries of 6 canines and made them go through the tubes and anastomosed them end-to-side to get the aneurysm model. Six stents were implanted after one week. Results: Six aneurysm models were successfully made in canines. The parent artery had similar geometry of the human carotid siphon. All the aneurysms and parent arteries were patent in one week's follow-up. One canine died of excessive anesthesia after stenting. Two vascular models kept patent in one month without stenosis. The other 3 had some stenosis on the bends of the vessel. Conclusions: The aneurysm model in the experiment has high flexibility and reliability. The model provides an effective tool for research and testing neurovascular devices. It's also a useful device to train the neuroradiologists and interventional physicians. (authors)

  13. DURAL CAROTID-CAVERNOUS FISTULAS

    Directory of Open Access Journals (Sweden)

    Barbara Cvenkel

    2002-12-01

    Full Text Available Background. Dural carotid-cavernous sinus fistulas (CCF are communications fed by meningeal branches of the intracavernous internal carotid artery (ACI or/and external carotid artery (ACE. In contrast to typical CCF, the arteriovenous shunting of blood is usually low flow and low pressure. Spontaneous dural CCF are more common in postmenopausal women. Aetiology is unknown, but congenital malformation or rupture of thin-walled dural arteries within venous sinuses is believed to be the cause.Case reports. 3 cases lacking the typical clinical signs of CCF who had been treated as chronic conjunctivitis, myositis of the extraocular muscle and orbital pseudotumour are presented. Clinical presentation depends on the direction and magnitude of fistular flow and on the anatomy of the collateral branches. If increased blood flow is directed anteriorly in ophthalmic veins the signs of orbito-ocular congestion are present (»redeyed shunt syndrome«. Drainage primarly in the inferior petrosal sinus may cause painful oculomotor and abducens palsies without signs of ocular congestion (»white-eyed shunt syndrome«. Also different therapeutic approaches as well as possible complications are described.Conclusions. For definite diagnosis angiography is obligatory and is also therapeutic as one third to one half of dural CCF close spontaneously. Because of potential severe eye and systemic complications, surgical intervention is indicated only in cases with uncontrolled secondary glaucoma and hypoxic retinopathy.

  14. [Coronary stents: 30 years of medical progress].

    Science.gov (United States)

    Silvain, Johanne; Cayla, Guillaume; Collet, Jean-Philippe; Fargeot, Catherine; Montalescot, Gilles

    2014-03-01

    The history of interventional cardiology has been marked by several technologic revolutions since the late 1970s. The first key step was the use of inflatable balloon angioplasty as an alternative to CABG surgery for coronary revascularization, followed by intracoronary delivery of bare metal stent (BMS) and drug eluting stents (DES) to drastically reduce intracoronary restenosis observed with BMS. Improved stents platforms and polymers (absorbable or biocompatible) led to a dramatic reduction in the rate of late stent thrombosis. Self-expanding stents are now available to improve stent a position especially in acute myocardial infarction. The emergence of new fully bioabsorbable stents that can be combined with antiproliferative drugs is the ongoing revolution. A new generation of stents is continuously improving and likely to become the ideal stent for coronary revascularization in the near future. © 2014 médecine/sciences – Inserm.

  15. Percutaneous reconstruction of the innominate bifurcation using the retrograde 'kissing stents' technique

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Shun-ichi; Kazekawa, Kiyoshi; Matsubara, Shuko [Fukuoka University Chikushi Hospital, Department of Neurosurgery, Chikushino, Fukuoka (Japan); Sugata, Sei [Bironoki Neurosurgical Hospital, Shibushi, Kagoshima (Japan)

    2006-08-15

    Obstructions of the supraaortic vessels are an important cause of morbidity associated with a variety of symptoms. Percutaneous transluminal angioplasty has evolved as an effective and safe treatment modality for occlusive lesions of the supraaortic vessels. However, the endovascular management of an innominate bifurcation has not previously been reported. A 53-year-old female with a history of systematic hypertension, diabetes mellitus and hypercholesterolemia presented with left hemiparesis and dysarthria. Angiography of the innominate artery showed a stenosis of the innominate bifurcation. The lesion was successfully treated using the retrograde kissing stent technique via a brachial approach and an exposed direct carotid approach. The retrograde kissing stent technique for the treatment of a stenosis of the innominate bifurcation was found to be a safe and effective alternative to conventional surgery. (orig.)

  16. Percutaneous reconstruction of the innominate bifurcation using the retrograde 'kissing stents' technique

    International Nuclear Information System (INIS)

    Nagata, Shun-ichi; Kazekawa, Kiyoshi; Matsubara, Shuko; Sugata, Sei

    2006-01-01

    Obstructions of the supraaortic vessels are an important cause of morbidity associated with a variety of symptoms. Percutaneous transluminal angioplasty has evolved as an effective and safe treatment modality for occlusive lesions of the supraaortic vessels. However, the endovascular management of an innominate bifurcation has not previously been reported. A 53-year-old female with a history of systematic hypertension, diabetes mellitus and hypercholesterolemia presented with left hemiparesis and dysarthria. Angiography of the innominate artery showed a stenosis of the innominate bifurcation. The lesion was successfully treated using the retrograde kissing stent technique via a brachial approach and an exposed direct carotid approach. The retrograde kissing stent technique for the treatment of a stenosis of the innominate bifurcation was found to be a safe and effective alternative to conventional surgery. (orig.)

  17. Stenting of major airway constriction

    International Nuclear Information System (INIS)

    Wu Xiaomei

    2002-01-01

    Objective: To investigate the correlated issues in the stenting treatment of major airway constriction. Methods: Nineteen cases of major airway stenting procedure were studied retrospectively. The clinical choice of stents of different advantages or deficiencies were discussed. The importance of intravenous anesthesia supporting, life-parameters monitoring during the procedures and the prevention of complications were analysed. Results: Under intravenous and local anesthesia, 19 Wallstents had been successively placed and relieved 19 cases of major airway constrictions due to malignant or benign diseases (15 of tumors, 3 of tuberculosis, 1 of tracheomalacia). Intravenous anesthesia and life-parameters monitoring had made the procedures more safe and precise. Conclusions: Major airway stenting is an reliable method for relieving tracheobronchial stenosis; and intravenous anesthesia supporting and life-parameters monitoring guarantee the satisfactions of procedures

  18. Transcervical, intrauterine ultrasound-guided radiofrequency ablation of uterine fibroids with the VizAblate? System: three- and six-month endpoint results from the FAST-EU study

    OpenAIRE

    Bongers, Marlies; Br?lmann, Hans; Gupta, Janesh; Garza-Leal, Jos? Gerardo; Toub, David

    2014-01-01

    This was a prospective, longitudinal, multicenter, single-arm controlled trial, using independent core laboratory validation of MRI results, to establish the effectiveness and confirm the safety of the VizAblate? System in the treatment of symptomatic uterine fibroids. The VizAblate System is a transcervical device that ablates fibroids with radiofrequency energy, guided by a built-in intrauterine ultrasound probe. Fifty consecutive women with symptomatic uterine fibroids received treatment w...

  19. Primary Stenting of Subclavian and Innominate Artery Occlusive Disease: A Single Center's Experience

    International Nuclear Information System (INIS)

    Brountzos, E. N.; Petersen, B.; Binkert, C.; Panagiotou, I.; Kaufman, J. A.

    2004-01-01

    Purpose: To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Methods: Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Results: Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Conclusion: Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions

  20. Comparison of Acute Thrombogenicity for Magnesium versus Stainless Steel Stents in a Porcine Arteriovenous Shunt Model.

    Science.gov (United States)

    Lipinski, Michael J; Acampado, Eduardo; Cheng, Qi; Adams, Lila; Torii, Sho; Gai, Jiaxiang; Torguson, Rebecca; Hellinga, David G; Joner, Michael; Harder, Claus; Zumstein, Philine; Finn, Aloke V; Kolodgie, Frank D; Virmani, Renu; Waksman, Ron

    2018-05-08

    Aims The aetiology for reduced thrombogenicity of the Magmaris resorbable magnesium scaffold (RMS) when compared with the Absorb bioresorbable vascular scaffold remains unclear. We therefore investigated whether the Magmaris RMS has platelet-repelling properties by comparing its acute thrombogenicity with an equivalent stainless steel stent in an arteriovenous shunt model. Methods and Results An ex vivo porcine carotid jugular arteriovenous shunt was established and connected to Sylgard tubing containing the Magmaris RMS with sirolimus-eluting PLLA coating and an equivalent 316L stainless steel stent with sirolimus-eluting PLLA coating. Six shunts (2 shunt runs per pig) were run comparing the 2 scaffolds (n=9) in alternating order. Nested generalised linear mixed models were employed to compare variables between scaffold groups. Confocal fluorescent microscopy costaining CD61/CD42b demonstrated that the 316L equivalent stent had significantly greater platelet coverage of the total scaffold compared with Magmaris (5.8% vs. 2.8%, Rate ratio 2.21 [1.41, 3.47], p=0.012). Scanning electron microscopy demonstrated significantly greater thrombus deposition on the 316L equivalent stent as a percentage of the total scaffold compared with Magmaris (8.0% vs. 5.3%, p=0.009). Magmaris also had significantly less CD14 positive monocyte deposition and a trend toward less PM-1 positive neutrophil compared with the 316L equivalent stent. Conclusion Despite having identical scaffold characteristics regarding geometrical design, Magmaris had significantly less thrombogenicity and inflammatory cell deposition compared with the equivalent 316L stainless steel stent in a porcine arteriovenous shunt model. These data suggest resorbable magnesium scaffolds may have inherent properties that reduce adhesion of platelets and inflammatory cells.

  1. Safety of carotid endarterectomy in patients concurrently on clopidogrel.

    Science.gov (United States)

    Fleming, Mark D; Stone, William M; Scott, Paul; Chapital, Alyssa B; Fowl, Richard J; Money, Samuel R

    2009-01-01

    Clopidogrel (Plavix) usage is increasing, primarily for the management of patients with cerebrovascular symptoms and for those receiving drug-eluting coronary artery stents. A significant percentage of these patients will require carotid endarterectomy (CEA) while they are receiving clopidogrel. Recent data have demonstrated an increased incidence of coronary stent thrombosis when clopidogrel is discontinued. The objective of this study was to determine if CEA could be performed safely while patients are continued on clopidogrel therapy. A retrospective cohort design was employed to review consecutive patients who underwent CEA over a 24-month period ending March 2007. Patients were divided into two groups based on the perioperative use of clopidogrel. Preoperative demographics and postoperative results were compared between the two groups and statistically analyzed. Of the 100 patients who underwent CEA, 19 were taking clopidogrel within 5 days of surgery. This comprised the study group. The control group consisted of the 81 patients who did not receive clopidogrel. Heparin anticoagulation was routinely utilized prior to clamping in both groups. Demographics were similar between the groups. There were no statistical differences in morbidity or mortality between the control group and the clopidogrel group. Combined stroke/death rates were equivalent between the two groups (1.2% control vs. 0% clopidogrel). One hematoma developed in the control group, which did not require operative intervention. In this series, our results suggest that patients concurrently on clopidogrel can safely undergo CEA without increased risk of hematoma or neurological complications. In view of recent data demonstrating adverse outcomes in patients discontinuing clopidogrel, this study is useful in optimally managing this group of patients.

  2. Novel J stents reduce the risk of embolic stroke in vitro

    International Nuclear Information System (INIS)

    Bartoli, Carlo R.; Spence, Paul A.; Giridharan, Guruprasad A.

    2010-01-01

    Two and a half million Americans with atrial fibrillation are at an elevated risk for embolic stroke. Warfarin therapy is standard treatment for high-risk patients, yet 40-65% of elderly patients do not receive anticoagulation therapy due to bleeding complications. To address this clinical need, we are evaluating a minimally invasive stent-based stroke prevention device to divert emboli from entering the arterial supply of the brain. The feasibility of a J-shaped stroke prevention device was tested in a mock circulatory loop. Sixteen sets of 100 simulated emboli (1-5 mm 3 ) were injected into the left atrium with and without J stents protecting the aortic arch vessels. To determine efficacy, emboli were trapped in filters in the aortic arch vessels and distal aorta for manual counting. J stents decreased the number of emboli that entered the brachiocephalic trunk by 93.7% (p<0.0001), left common carotid artery by 79.8% (p<0.0001), and left subclavian artery by 89.7% (p<0.0001). In a mock circulation, J stents positioned in the aortic arch vessels and oriented downstream of aortic flow significantly decreased the number of emboli that entered the aortic arch vessels. These results warrant further investigation to determine the safety and efficacy of this prophylactic intervention to reduce embolic events, and chronic large animal studies are underway. (orig.)

  3. Novel J stents reduce the risk of embolic stroke in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Bartoli, Carlo R. [University of Louisville, M.D./Ph.D. Program, Louisville, KY (United States); Spence, Paul A. [SCR Inc., Louisville, KY (United States); Giridharan, Guruprasad A. [Cardiovascular Innovation Institute, University of Louisville, Department of Bioengineering, Louisville, KY (United States)

    2010-05-15

    Two and a half million Americans with atrial fibrillation are at an elevated risk for embolic stroke. Warfarin therapy is standard treatment for high-risk patients, yet 40-65% of elderly patients do not receive anticoagulation therapy due to bleeding complications. To address this clinical need, we are evaluating a minimally invasive stent-based stroke prevention device to divert emboli from entering the arterial supply of the brain. The feasibility of a J-shaped stroke prevention device was tested in a mock circulatory loop. Sixteen sets of 100 simulated emboli (1-5 mm{sup 3}) were injected into the left atrium with and without J stents protecting the aortic arch vessels. To determine efficacy, emboli were trapped in filters in the aortic arch vessels and distal aorta for manual counting. J stents decreased the number of emboli that entered the brachiocephalic trunk by 93.7% (p<0.0001), left common carotid artery by 79.8% (p<0.0001), and left subclavian artery by 89.7% (p<0.0001). In a mock circulation, J stents positioned in the aortic arch vessels and oriented downstream of aortic flow significantly decreased the number of emboli that entered the aortic arch vessels. These results warrant further investigation to determine the safety and efficacy of this prophylactic intervention to reduce embolic events, and chronic large animal studies are underway. (orig.)

  4. Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

    Science.gov (United States)

    Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian

    2016-04-01

    Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location. We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type. After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.

  5. Intervention on Surgical Systemic-to-Pulmonary Artery Shunts: Carotid Versus Femoral Access.

    Science.gov (United States)

    Ligon, R Allen; Ooi, Yinn K; Kim, Dennis W; Vincent, Robert N; Petit, Christopher J

    2017-09-11

    The purpose of this study was to compare results between the femoral arterial (FA) and carotid arterial (CA) approaches in catheter-based interventions on Blalock-Taussig shunts (BTS). Transcatheter intervention on BTS is often performed in shunt-dependent, hypoxemic infants. The approach to BTS intervention likely has an impact on timeliness and overall success. The authors reviewed all cases of catheter intervention for BTS obstruction between 2012 and 2017 for their institution. They sought to compare procedural success rates and time, sheath time, time to arterial access, and time from access to stent implantation between FA and CA approaches. There were 42 BTS interventions between 34 patients. BTS intervention was more successful from the CA approach (p = 0.035). Among the FA cohort, BTS intervention was unsuccessful in 8 cases (25%), 5 of which were converted to CA with subsequent success. The CA cohort had lower procedure time (62 min vs. 104 min; p = 0.01) and anesthesia time (119 min vs. 151 min; p = 0.01). Additionally, CA access was associated with shorter time to arterial access (4.0 min vs. 9.3 min; p BTS (6.5 min vs. 13 min; p BTS stent implantation (9 min vs. 20 min; p BTS deliberately. The authors' approach has been the carotid artery as an alternative access site-associated with greater procedural success, shorter procedural time, and shorter time to stent implantation. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Establishing experimental model of human internal carotid artery siphon segment in canine common carotid artery

    International Nuclear Information System (INIS)

    Cui Xuee; Li Minghua; Wang Yongli; Cheng Yingsheng; Li Wenbin

    2005-01-01

    Objective: To study the feasibility of establishing experimental model of human internal carotid artery siphon segment in canine common carotid artery (CCA) by end-to-end anastomoses of one side common carotid artery segment with the other side common carotid artery. Methods: Surgical techniques were used to make siphon model in 8 canines. One side CCA was taken as the parent artery and anastomosing with the cut off contra-lateral CCA segment which has passed through within the S-shaped glass tube. Two weeks after the creation of models angiography showed the model siphons were patent. Results: Experimental models of human internal carotid artery siphon segment were successfully made in all 8 dogs. Conclusions: It is practically feasible to establish experimental canine common carotid artery models of siphon segment simulating human internal carotid artery. (authors)

  7. Endovascular treatment of radiation-induced carotid blowout syndrome. Report of two cases

    International Nuclear Information System (INIS)

    Adachi, Akihiko; Kobayashi, Eiichi; Watanabe, Yoshiyuki; Yoneyama, Tomoko S.; Hayasaka, Michihiro; Suzuki, Homare; Okamoto, Yoshitaka; Saeki, Naokatsu

    2011-01-01

    Carotid Blowout Syndrome (CBS), or Carotid Artery Rupture (CAR), is a delayed complication with potentially fatal consequences occurring after the implementation of radiotherapy on head and neck tumors. In this report we describe two patients received endovascular treatment for severe hemorrhagic CBS developing 36 and 2 years, respectively, after radiotherapy. Both patients survived and responded positively to treatment. Case 1 was an 80-year-old woman found with minor hemorrhage near the bifurcation of the common carotid artery, 36 years after neck irradiation. She experienced frequent hemorrhagic events during the following years. Six years after the initial discovery of bleeding, she experienced massive hemorrhage, lapsed into shock, and was admitted to an Emergency Room. Connective tissue around the carotid artery was largely exposed due to neck skin defect. After hemorrhage was halted by manual compression, transient hemostasis was achieved with coil embolization of the aneurysm presumed to be the source of bleeding. Recurrent hemorrhage developed two weeks later with unraveled coil mass extrusion. Parent artery occlusion was performed by endovascular trapping, achieving permanent hemostasis. Case 2 presented massive nasal bleeding originating from the petrous segment of the internal carotid artery, 2 years after having been treated with heavy particle irradiation for olfactory neuroblastoma. Ischemic tolerance was confirmed by balloon occlusion test. Based on previous experiences, the bleeding was immediately halted by endovascular trapping. Both patients were subsequently discharged, free of new neurological symptoms. Emergent hemostatic treatment is required in CBS developing severe hemorrhage. However, within irradiation fields, temporal embolization devices hardly lead to complete resolution. This is due to the deteriorated condition of the vascular wall incapable to enduring the expansion power of coils, stents or balloons. Bypass grafting is also

  8. Hemodynamic significance of internal carotid artery disease

    DEFF Research Database (Denmark)

    Schroeder, T

    1988-01-01

    Neurologic symptoms in the region of an internal carotid artery stenosis are considered to be embolic in most instances. Only in a subgroup has carotid occlusive disease with impairment of the collateral supply, caused a state of hemodynamic failure with marked reduction of perfusion pressure. Th...

  9. Stent migration after right ventricular outflow tract stenting in the severe cyanotic Tetralogy of Fallot case

    Directory of Open Access Journals (Sweden)

    Tamaki Hayashi

    2017-01-01

    Full Text Available We report our experience with a stent migration after right ventricle outflow tract stenting and converted to patent ductus arteriosus stenting in Tetralogy of Fallot (TOF with severe infundibular stenosis. Finally, the patient achieved to TOF repair, and the migrated stent was removed without any complication.

  10. Intrasellar Iatrogenic Carotid Pseudoaneurysm: Endovascular Treatment with a Polytetrafluoroethylene-Covered S tent

    International Nuclear Information System (INIS)

    Vanninen, R. L.; Manninen, H. I.; Rinne, J.

    2003-01-01

    This case illustrates successful treatment of a large postoperative intrasellar pseudoaneurysm with a polytetrafluoroethylene (PTFE)-covered stent. The advantages and potential disadvantages of this novel method of treatment are discussed. A previously healthy 59-year-old man underwent transsphenoidal operative treatment for hypophyseal macroadenoma,complicated by bleeding. On the 17 th postoperative day the patient had profuse arterial bleeding from his nose requiring posterior tamponade. Subsequent angiography of the left internal carotid artery(ICA) revealed a large pseudoaneurysm located intrasellarly, with the orifice in the anteromedial wall in the ophthalmic segment of the ICA.Surgical treatment of the pseudoaneurysm was considered very risky. A12-mm PTFE-covered stent (JoMed, Ulestraten, Netherlands), manually compressed on a PTCA-balloon (Maxxum 4.5/13 mm, Boston Scientific,Ireland) was endovascularly delivered covering the orifice of the pseudoaneurysm. Control angiography immediately after the intervention and one year later revealed no flow into the pseudoaneurysm and the ICA was fully patent. In conclusion, deployment of a PTFE-covered stent proved to be feasible and successful in the treatment of an intrasellariatrogenic ICA pseudoaneurysm. Adequate anticoagulative treatment after the procedure is essential to prevent thrombotic complications

  11. Cerebral hyperperfusion syndrome after carotid angioplasty

    International Nuclear Information System (INIS)

    Milosevic, Z.; Surlan, M.; Zvan, B.; Zaletel, M.

    2002-01-01

    Background. Cerebral hyperperfusion syndrome after carotid endarterectomy is an uncommon but well-defined entity. There are only few reports of ''hyperperfusion injury'' following carotid angioplasty. Case report. We report an unstable arterial hypertension and high-grade carotid stenosis in a 58-year-old, right-handed woman. After a stroke in the territory of middle cerebral artery carotid angioplasty was performed in the patient. Among risk factors, the long lasting arterial hypertension was the most pronounced. Immediately after the procedure, the patient was stable without any additional neurologic deficit. The second day, the patient had an epileptic seizure and CT revealed a small haemorrhage in the left frontal lobe. Conclusions. The combination of a high-grade carotid stenosis and unstable arterial pressure is probably an important prognostic factor in the pathogenesis of hyperperfusion syndrome. (author)

  12. Mechanisms of Biliary Plastic Stent Occlusion and Efforts at Prevention

    Directory of Open Access Journals (Sweden)

    Chang-Il Kwon

    2016-03-01

    Full Text Available Biliary stenting via endoscopic retrograde cholangiopancreatography has greatly improved the quality of patient care over the last 30 years. Plastic stent occlusion limits the life span of such stents. Attempts to improve plastic stent patency duration have mostly failed. Metal stents (self-expandable metal stents [SEMSs] have therefore replaced plastic stents, especially for malignant biliary strictures. SEMS are at least 10 times more expensive than plastic stents. In this focused review, we will discuss basic mechanisms of plastic stent occlusion, along with a systematic summary of previous efforts and related studies to improve stent patency and potential new techniques to overcome existing limitations.

  13. Angioplasty and stent placement - peripheral arteries - discharge

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000234.htm Angioplasty and stent placement - peripheral arteries - discharge To use the sharing ... peripheral artery). You may have also had a stent placed. To perform the procedure: Your doctor inserted ...

  14. Angioplasty and stent placement - peripheral arteries

    Science.gov (United States)

    ... medlineplus.gov/ency/article/007393.htm Angioplasty and stent placement - peripheral arteries To use the sharing features ... inside the arteries and block blood flow. A stent is a small, metal mesh tube that keeps ...

  15. Prolonged carotid sinus reflex is a risk factor for contrast-induced nephropathy following carotid artery stenting.

    Science.gov (United States)

    Kato, T; Sakai, H; Tsujimoto, M; Nishimura, Y

    2011-03-01

    Although many studies have demonstrated that CIN is associated with in-hospital and long-term mortality, the incidence of CIN following CAS is unclear. We investigated the incidence of CIN, defined as an increase from a baseline creatinine value of at least 0.5 mg/dL or 25% within 72 hours of contrast administration, and we also examined renal function in the late phase after CAS. We examined 80 patients who underwent CAS between April 2005 and December 2009. Clinical background, laboratory data, contrast volume, and clinical course were collected and analyzed. The incidence of CIN was 8.8% (7/80), and no patients required hemodialysis. In the group that developed CIN, prolonged CSR after CAS was found in 57.1% (4/7) of cases; this incidence differed significantly (P = .001) from that in the group without development of CIN. Neither preoperative renal function, contrast volume, nor history was related to the incidence of CIN, while on multivariate analysis, prolonged CSR was found to be an independent risk factor for CIN. The incidence of elevation in creatinine values at 6 months after CAS was 8.2% (6/73). All patients who developed delayed renal impairment had pre-existing CKD; this finding differed significantly (P = .04) from that in the group without development of delayed renal impairment. Because patients who develop prolonged CSR after CAS are at increased risk of perioperative major adverse clinical events including CIN, patients at high risk for this condition should be carefully managed to prevent increased morbidity and mortality.

  16. Management of stent dislodgment in coarctoplasty of aorta with three overlapping self-expandable nitinol stents.

    Science.gov (United States)

    Ghazi, Payam; Haji-Zeinali, Ali-Mohammad

    2010-01-01

    We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.

  17. Dual Antiplatelet Therapy Does Not Increase the Risk of Bleeding After Carotid Endarterectomy: Results of a Prospective Study.

    Science.gov (United States)

    Illuminati, Giulio; Schneider, Fabrice; Pizzardi, Giulia; Masci, Federica; Calio', Francesco G; Ricco, Jean-Baptiste

    2017-04-01

    The purpose of this study was to evaluate the risk of bleeding and other postoperative complications of carotid endarterectomy (CEA) in patients receiving dual antiplatelet therapy (DAPT). From January 2005 to December 2015, 188 consecutive patients undergoing CEA and receiving DAPT (aspirin 100 mg + clopidogrel 75 mg) were enrolled in a prospective study. All of them underwent coronary artery stenting with drug-eluting stents during the 6 months preceding CEA. In the entire series, DAPT was continued until the evening before CEA and resumed on the evening of the operation. All patients received intraoperative heparinization (5,000 IU before carotid clamping), which was reversed in 5 patients. In addition, all of them were given 2,000 units of enoxaparin every 12 hr after the operation, beginning 6 hr after completion of the operation, and until discharge. All the patients presented with carotid artery stenosis >70% (North American Symptomatic Carotid Endarterectomy Trial [NASCET] criteria), which was symptomatic in 42 patients (transient ischemic attack, n = 32; minor stroke, n = 10) and asymptomatic in 146. The CEA technique was standard, with prosthetic patch closure in 109 cases (58%) and eversion in 79 (42%). The primary endpoints of the study were occurrence of a postoperative cervical hematoma requiring surgical hemostasis and occurrence of cranial nerve injuries. The secondary endpoint was the combined rate of postoperative mortality, stroke, and myocardial ischemia. No postoperative cervical hematoma requiring surgical evacuation occurred in this series. One hypoglossal nerve palsy, regressive within 2 weeks, was observed. Postoperative mortality and neurologic and cardiac morbidity were nil. CEA under DAPT yields results comparable with those obtained in patients receiving a single antiplatelet treatment. No hemorrhagic complications were observed in this prospective series. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Plastic biliary stents for malignant biliary diseases

    NARCIS (Netherlands)

    Huibregtse, Inge; Fockens, Paul

    2011-01-01

    Plastic biliary endoprostheses have not changed much since their introduction more than 3 decades ago. Although their use has been challenged by the introduction of metal stents, plastic stents still remain commonly used. Much work has been done to improve the problem of stent obstruction but

  19. Therapies targeting inflammation after stent implantation.

    Science.gov (United States)

    Okura, Hiroyuki; Takagi, Tsutomu; Yoshida, Kiyoshi

    2013-07-01

    Since the introduction of coronary vessel scaffold by metallic stent, percutaneous coronary intervention has become widely performed all over the world. Although drug-eluting stent technology has further decrease the incidence of in-stent restenosis, there still remaining issues related to stent implantation. Vessel inflammation is one of the causes that may be related to stent restenosis as well as stent thrombosis. Therefore, systemic therapies targeting inflammation emerged as adjunctive pharmacological intervention to improve outcome. Statins, corticosteroids, antiplatelets, and immunosuppresive or anti-cancer drugs are reported to favorably impact outcome after bare-metal stent implantation. In type 2 diabetic patients, pioglitazone may be the most promising drug that can lower neointimal proliferation and, as a result, lower incidence of restenosis and target lesion revascularization. On the other hand, several new stent platforms that might decrease inflammatory response after drug-eluting stent implantation have been introduced. Because durable polymer used in the first generation drug-eluting stents are recognized to be responsible for unfavorable vessel response, biocompatible or bioabsorbable polymer has been introduce and already used clinically. Furthermore, polymer-free drug-eluting stent and bioresorbable scaffold are under investigation. Although vessel inflammation may be reduced by using these new drug-eluting stents or scaffold, long-term impact needs to be investigated further.

  20. Incidence and predictors of coronary stent thrombosis

    DEFF Research Database (Denmark)

    D'Ascenzo, Fabrizio; Bollati, Mario; Clementi, Fabrizio

    2013-01-01

    Stent thrombosis remains among the most feared complications of percutaneous coronary intervention (PCI) with stenting. However, data on its incidence and predictors are sparse and conflicting. We thus aimed to perform a collaborative systematic review on incidence and predictors of stent...

  1. 21 CFR 876.4620 - Ureteral stent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ureteral stent. 876.4620 Section 876.4620 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4620 Ureteral stent. (a) Identification. A ureteral stent...

  2. 21 CFR 884.3900 - Vaginal stent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vaginal stent. 884.3900 Section 884.3900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES... stent. (a) Identification. A vaginal stent is a device used to enlarge the vagina by stretching, or to...

  3. Metallic ureteral stents in malignant ureteral obstruction: clinical factors predicting stent failure.

    Science.gov (United States)

    Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin

    2014-06-01

    To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.

  4. Diagnosis of carotid artery stegnosis

    International Nuclear Information System (INIS)

    Uwatoko, Takeshi; Okada, Yasushi

    2008-01-01

    Carotid Artery Stegnosis (CAS) is an important cause of the crisis of atherothrombotic cerebral infarction. This paper describes diagnosis and evaluation of CAS by echo and MRI/MR angiography (MRA) together with its clinical characteristics. Two hundreds Japanese patients undergone with carotid endarterectomy in authors' hospital are found to have had complications of coronary lesions in 38% and arteriosclerosis obliterans in 13%. Echo is a useful and simple method for detection of dynamic state of CAS and in cerebral infarction, diagnosis to decide whether the plaque is the culprit lesion is important as well as to decide the degree of stegnosis. The lesion is detected through the B mode method and the degree, through the color Doppler imaging; and blood flow rate and its waveform can be evaluated. MRI/MRA has advantages of its objectivity and wide imaging range. The MRI/MRA using various imaging techniques like black-blood method by spin echo or gradient echo modes and fat-suppression combination is advantageous and expectedly to be further developed for evaluation of plaque nature and status leading to therapeutic planning. Thus the degree of stegnosis and vulnerability of the plaque evaluated by echo and MRI/MRA of the cervical artery will be more important for judging the surgical applicability of circulatory reconstruction. (R.T.)

  5. Anomalous external carotid artery-internal carotid artery anastomosis in two patients with proximal internal carotid arterial remnants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hun [Dept. of Neurology, Stroke Center, Myongji Hospital, Goyang (Korea, Republic of); Cho, Young Dae; Kang, Hyun Seung; Kim, Jeong Eun; Han, Moon Hee [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seung Chai [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ahn, Jun Hyong [Dept. of Neurosurgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2015-08-15

    Two angiographic instances of anomalous external carotid artery (ECA) and internal carotid artery (ICA) anastomosis are described, each occurring at the C2-3 level and bearing remnants of proximal ICA. The ICA remnant of one patient (identifiable immediately upon bifurcation of the common carotid artery) was hypoplastic, and that of the other patient was an occluded arterial stump. These features are not typical of non-bifurcating ICA. The occipital artery originated from an anomalous connection in one instance and from the main trunk of the ECA (just past the ECA-ICA connection) in the other.

  6. Coronary and peripheral stenting in aorto-ostial protruding stents: The balloon assisted access to protruding stent technique.

    Science.gov (United States)

    Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R

    2016-03-01

    Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.

  7. A Comparison of Stent Implant versus Medical Treatment for Severe Symptomatic Intracranial Stenosis: A Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Rezao Mohammadian

    2012-11-01

    Full Text Available Background: Atherosclerotic stenosis of the major intracranial arteries is the most common cause of ischemic stroke. There are limited treatments for severe intracranial stenosis, and stent placement versus medical treatment remains controversial. The aim of this study was to compare functional outcomes of these two modalities in patients with severe symptomatic intracranial stenosis. Methods: At a single center, between 2008 and 2011, patients with angiographically demonstrated severe (70–90% symptomatic intracranial atherosclerosis were divided into two groups: group A, which received only medical treatment, and group B, which underwent endovascular stent implant treatment. The severity and location of the stenosis was determined by digital subtraction angiography and the Warfarin-Aspirin Symptomatic Intracranial Disease (WASID trial criteria in all patients. The exclusion criteria were: specific causes other than atherosclerosis, such as artery dissection, fibromuscular dysplasia, vasculitis, radiation and intracranial hemorrhage, focal neurological deficit that did not correlate to internal carotid artery or middle cerebral artery stenosis. All procedures were done under light anesthesia. Technical success was defined as the reduction of stenosis to Results: Overall, 63 patients (29 in group A and 34 in group B were evaluated and followed for a mean period of 15.22 months (range 6–25. The technical success rate was 97% in a total of 34 stents in 34 patients. There was no difference between the early (within 30 days adverse event rates of the two groups. The median follow-up duration for the stent implant patients was 15 months (range 6–25, and for the medically treated cohort it was 14 months (range 8–25. The re-stenosis rate was 5.8% and the total number of late (>30 days adverse events, including stroke, myocardial infarction and death, was 1 (2.9% and 6 (20.7% in the stent implant and medical groups, respectively (p = 0.042. The

  8. Visual Aids for Improving Patient Decision Making in Severe Symptomatic Carotid Stenosis.

    Science.gov (United States)

    Fridman, Sebastian; Saposnik, Gustavo; Sposato, Luciano A

    2017-12-01

    Because of the large amount of information to process and the limited time of a clinical consult, choosing between carotid endarterectomy (CEA) and carotid angioplasty with stenting (CAS) can be confusing for patients with severe symptomatic internal carotid stenosis (ICA). We aim to develop a visual aid tool to help clinicians and patients in the decision-making process of selecting between CEA and CAS. Based on pooled analysis from randomized controlled trials including patients with symptomatic and severe ICA (SSICA), we generated visual plots comparing CEA with CAS for 3 prespecified postprocedural time points: (1) any stroke or death at 4 months, and (2) any stroke or death in the first 30 days and ipsilateral stroke thereafter at 5 years and (3) at 10 years. A total of 4574 participants (2393 assigned to CAS, and 2361 to CEA) were included in the analyses. For every 100 patients with SSICA, 6 would develop any stroke or death in the CEA group compared with 9 undergoing CAS at 4 months (hazard ratio [HR] 1.53; 95%CI 1.20-1.95). At 5 years, 7 patients in the CEA group would develop any periprocedural stroke or death and ipsilateral stroke thereafter versus 12 undergoing CAS (HR 1.72; 95%CI 1.24-2.39), compared with 10 patients in the CEA and 13 in the CAS groups at 10 years (HR 1.17; 95%CI 0.82-1.66). Visual aids presented in this study could potentially help patients with severe symptomatic internal carotid stenosis to better weigh the risks and benefits of CEA versus CAS as a function of time, allowing for the prioritization of personal preferences, and should be prospectively assessed. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  9. Experimental absorbable stent permits airway remodeling.

    Science.gov (United States)

    Liu, Kuo-Sheng; Liu, Yun-Hen; Peng, Yi-Jie; Liu, Shih-Jung

    2011-02-01

    Despite metallic and silicone stents being effective in treating various airway lesions, many concerns still remain. A bioresorbable stent that scaffolds the airway lumen and dissolves after the remodeling process is completed has advantages over metallic and silicone stents. We designed and fabricated a new mesh-type bioresorbable stent with a backbone of polycaprolactone (PCL), and evaluated its safety and biocompatibility in a rabbit trachea model. The PCL stent was fabricated by a laboratory-made microinjection molding machine. In vitro mechanical strength of the PCL stents was tested and compared to that of commercial silicone stents. The bioresorbable stents were surgically implanted into the cervical trachea of New Zealand white rabbits (n=6). Animals received bronchoscopic examination at 1, 2, 4, 8, and 12 weeks after surgery. Histological examination was completed to evaluate the biocompatibility of the stents. No animals died during the period of study. Distal stent migration was noted in 1 rabbit. In-stent secretion accumulation was found in 2 rabbits. Histological examination showed intact ciliated epithelium and marked leukocyte infiltration in the submucosa of the stented area at 10 and 28 weeks. Stent degradation was minimal, and the mechanical strength was well preserved at the end of 33 weeks. These preliminary findings showed good safety and biocompatibility of the new PCL stent when used in the airway remodeling. PCL could be a promising bioresorbable material for stent design if prolonged degradation time is required. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  10. Carotid artery stenosis after neck radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shimamura, Munehisa; Hashimoto, Yoichiro; Kasuya, Junji; Terasaki, Tadashi [Kumamoto City Hospital (Japan); Uchino, Makoto

    2000-02-01

    Carotid artery stenosis sometimes occurs after cervical radiotherapy. We report a 70-year-old woman with a history of radiotherapy for thyroid cancer at the age of 28 years. She had no signs and symptoms except the skin lesion at the irradiation site. Duplex ultrasonography revealed heterogeneous plaques showing 50% stenosis of bilateral common carotid arteries. Those lesions were observed within segment of irradiation, where atheromatous plaque usually seldom occurs. These indicated that the carotid stenosis was induced by radiotherapy. Although the efficacy of antiplatelet therapy for radiation-induced plaque is not clear, the plaques remained unchanged for 4 years in spite of aspirin administration. (author)

  11. Carotid artery bypass in acute postendarterectomy thrombosis.

    Science.gov (United States)

    Paty, P S; Darling, R C; Cordero, J A; Shah, D M; Chang, B B; Leather, R P

    1996-08-01

    Carotid endarterectomy has demonstrated excellent results over the past 2 decades with combined stroke mortality of improvement in symptoms in 79% (11 of 14) of the patients and complete resolution in 57% (8 of 14). In long-term follow up (1 to 41 months), there have been no occlusions and one restenosis requiring revision at 11 months. Carotid artery bypass can be performed safely with acceptable results. The use of autogenous venous conduits allows reconstruction with an endothelial lined conduit that may improve results in patients with acute postoperative neurologic deficit secondary to thrombosis of the endarterectomized carotid artery.

  12. Presentation of a glomus carotid tumor as carotid sinus syndrome with syncopal episodes

    International Nuclear Information System (INIS)

    Dickschas, A.; Harmann, B.; Herzog, T.; Marienhagen, J.

    1987-01-01

    An 80 year old patient was referred to neurology for clarification of her episodes of syncope. A set of radiological examinations indicated a diagnosis of paraganglion of the left carotid bifurcation. Using this case, an attempt is made to provide recommendations concerning the order of step-wise visualization techniques of clarifying glomus carotid tumors. This unusual case also provides an impetus for considering the physiology and pathogenesis of different forms of carotid sinus syndrome. (orig.) [de

  13. Microvascular stent anastomosis using N-fibroin stents: feasibility, ischemia time, and complications.

    Science.gov (United States)

    Smeets, Ralf; Vorwig, Oliver; Wöltje, Michael; Gaudin, Robert; Luebke, Andreas M; Beck-Broichsitter, Benedicta; Rheinnecker, Michael; Heiland, Max; Grupp, Katharina; Gröbe, Alexander; Hanken, Henning

    2016-05-01

    To evaluate a novel microvascular anastomosis technique using N-fibroin stents. Cylinder stents of 1 mm diameter and 5 mm length were fabricated using N-fibroin from silkworms. In 22 rats, aortas were dissected, and the stent was inserted into the two ends of the aorta and fixed using methylmethacrylate. Stent anastomosis was successful in 21 (96%) rats. The mean ischemia time was 7.4 minutes, significantly shorter than the 15.9 minutes in the control group with conventional sutures (P stent anastomosis cases, and marked host rejection was evident at the stent anastomosis sites. Around the stents, thrombi were frequent (52%). Our study demonstrated the basic feasibility of stent anastomosis using N-fibroin stents and reduced ischemia time. However, thrombus formation, frequent and severe abdominal infections, and heavy host rejection remain critical issues. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Endoscopic stent suture fixation for prevention of esophageal stent migration during prolonged dilatation for achalasia treatment.

    Science.gov (United States)

    Rieder, E; Asari, R; Paireder, M; Lenglinger, J; Schoppmann, S F

    2017-04-01

    The aim of this study is to compare endoscopic stent suture fixation with endoscopic clip attachment or the use of partially covered stents (PCS) regarding their capability to prevent stent migration during prolonged dilatation in achalasia. Large-diameter self-expanding metal stents (30 mm × 80 mm) were placed across the gastroesophageal junction in 11 patients with achalasia. Stent removal was scheduled after 4 to 7 days. To prevent stent dislocation, endoscopic clip attachment, endoscopic stent suture fixation, or PCS were used. The Eckardt score was evaluated before and 6 months after prolonged dilatation. After endoscopic stent suture fixation, no (0/4) sutured stent migrated. When endoscopic clips were used, 80% (4/5) clipped stents migrated (p = 0.02). Of two PCS (n = 2), one migrated and one became embedded leading to difficult stent removal. Technical adverse events were not seen in endoscopic stent suture fixation but were significantly correlated with the use of clips or PCS (r = 0.828, p = 0.02). Overall, 72% of patients were in remission regarding their achalasia symptoms 6 months after prolonged dilatation. Endoscopic suture fixation of esophageal stents but not clip attachment appears to be the best method of preventing early migration of esophageal stents placed at difficult locations such as at the naive gastroesophageal junction. © The Authors 2017. Published by Oxford University Press on behalf of International Society for Diseases of the Esophagus. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Angulated Stents-A Novel Stent Improvisation to Manage Difficult Post-tuberculosis Bronchial Stenosis.

    Science.gov (United States)

    Tay, Chee Kiang; Jeong, Byeong-Ho; Kim, Hojoong

    2017-10-18

    Post-tuberculosis bronchostenosis (PTBS), a complication of endobronchial tuberculosis is currently treated by bronchial stenting. However, in cases of angulated bronchial stenoses, difficulty is often encountered in stent insertion and maintenance, resulting in stent migration, granulation tissue overgrowth, and restenosis. To accommodate the angulated alignment of the stenosis, we devised an "angulated stent"-a novel improvisation of the conventional stent via splicing and suturing to achieve a resultant angulated shape. A retrospective review was undertaken to evaluate the performance of this stent. Among 283 PTBS patients who underwent interventional bronchoscopy at our center from 2004 to 2014, 21 were treated with at least one angulated stent. Clinical outcomes, including the stenting duration were investigated. After a median follow-up of 26 months, stent removal was successful in 7 (33.3%) out of 21 patients. In patients managed with angulated stents, the median duration to stent change or eventual removal was longer than those treated with straight tube stents (392 days vs. 86 days; p < 0.05). Angulated stents are a feasible treatment option in patients with angulated PTBS by reducing complications and prolonging the stent-changing interval.

  16. Primary and revision efficacy of cross-wired metallic stents for endoscopic bilateral stent-in-stent placement in malignant hilar biliary strictures.

    Science.gov (United States)

    Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J

    2013-01-01

    Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Study on the effect of location of intracranial arterial stenosis on the safety of stenting

    Directory of Open Access Journals (Sweden)

    Yu-jie SUN

    2017-11-01

    Full Text Available Objective To investigate the effect of location of intracranial arterial stenosis on the safety of intracranial stenting. Methods A total of 73 patients with symptomatic intracranial atherosclerotic stenosis (ICAS were divided into intracranial internal carotid artery (IICA, N = 18, middle cerebral artery (MCA-M1 segment (MCA-M1, N = 11, intracranial vertebral artery (IVA, N = 27 and basilar artery (BA, N = 17. All of them underwent intracranial stenting. The improvement of intracranial arterial stenosis, cerebrovascular complications including perforating events, artery dissection, in-stent thrombosis, distal stent arterial embolism and cerebral hyperperfusion, and neurological complications including transient ischemic attack (TIA, ischemic stroke and intracranial hemorrhage were recorded. Modified Rankin Scale (mRS was used to evaluate the prognosis 30 d after operation. Results A total of 73 stents were implanted in 73 patients (35 Apollo balloon-expandable stents and 38 Wingspan self-expandable stents. Among them, 10 cases (10/18 were treated with Apollo stents and 8 cases (8/18 with Wingspan stents in IICA group, 5 cases (5/11 were treated with Apollo stents and 6 cases (6/11 with Wingspan stents in MCA-M1 group, 16 cases (59.26%, 16/27 were treated with Apollo stents and 11 cases (40.74%, 11/27 with Wingspan stents in IVA group, and 4 cases (4/17 were treated with Apollo stents and 13 cases (13/17 with Wingspan stents in BA group. No significant difference was seen in stent type among 4 groups (χ2 = 7.422, P = 0.201. The stenosis rate of IICA group after treatment [(10.94 ± 1.99%] was significantly improved than before treatment [(90.89 ± 7.71%; t = 69.545, P = 0.000]. The stenosis rate of MCA-M1 group after treatment [(10.37 ± 2.14%] was significantly improved than before treatment [(87.64 ± 9.46%; t = 26.000, P = 0.000]. The stenosis rate of IVA group after treatment [(11.02 ± 1.99% ] was significantly improved than before

  18. Intracranial carotid anastomosis and partial aplasia of an internal carotid artery

    International Nuclear Information System (INIS)

    Huber, G.

    1980-01-01

    A rare arterial anastomosis between the right and left interal carotid arteries at the base at the skull, with aplasia of the cervical part of the left internal carotid artery is reported. The case is unusual because, in addition to the vascular anomaly of the carotid artery, there is an aneurysm of the anterior communicating artery and bilateral renal cysts. The condition is a complex malformation syndrome caused by defective regression of the third branchial artery. Because of the characteristic angiographic aspects such a case should be called transverse carotid anastomosis. (orig.)

  19. Intracranial carotid anastomosis and partial aplasia of an internal carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Huber, G.

    1980-12-01

    A rare arterial anastomosis between the right and left internal carotid arteries at the base at the skull, with aplasia of the cervical part of the left internal carotid artery is reported. The case is unusual because, in addition to the vascular anomaly of the carotid artery, there is an aneurysm of the anterior communicating artery and bilateral renal cysts. The condition is a complex malformation syndrome caused by defective regression of the third branchial artery. Because of the characteristic angiographic aspects such a case should be called transverse carotid anastomosis.

  20. Resolution of carotid stenosis pre-carotid intervention: A case for selective preoperative duplex ultrasound.

    Science.gov (United States)

    Ali, Abid; Ashrafi, Mohammed; Zeynali, Iraj

    2015-01-01

    Spontaneous resolution of carotid stenosis is a phenomenon that has been described in literature in the past. At present it is not routine practise to scan patients prior to carotid endarterectomy surgery within the UK. A 58 year old female presented to hospital with a history of sudden onset headache and left sided weakness. CT head showed findings in keeping with an acute right MCA territory infarct. A duplex ultrasound scan showed echolucent material in the right internal carotid artery forming a greater than 95% stenosis. The scan was unable to visualise the patency of the vessel distally due to the position of the mandible. The patient was provisionally listed for carotid endarterectomy. An MRA was requested prior to surgery to assess the patency of the distal internal carotid artery. The MRA of the carotids showed normal appearance of the common carotid, internal and vertebral arteries with no definite stenosis. A repeat duplex ultrasound confirmed there was no significant stenosis. The finding of complete resolution of stenosis on MRA was an unexpected event. Had the initial duplex imaging allowed visualisation of the distal vessel patency, our patient would have undergone unnecessary carotid surgery with the associated morbidity and mortality. This case report draws attention to the benefits of selective preoperative scanning, in sparing patients from unnecessary surgery as a result of finding occlusion or resolution of a previously diagnosed carotid stenosis. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Endobronchial Occlusion Stent: A Preliminary Experimental Study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yo Won; Jeong, Woo Kyoung; Lee, Seoung Hoon; Heo, Jeong Nam; Jeon, Seok Chol [Hanyang University College of Medicine, Seoul (Korea, Republic of); Ko, Gi Young; Song, Ho Young [University of Ulsan College of Medicine, Ulsan (Korea, Republic of)

    2010-04-15

    To evaluate the safety and the technical feasibility of the use of an endobronchial occlusion stent and to get preliminary data for the development of the optimal material required for endobronchial occlusions. A commercialized, self-expandable tracheobronchial stent was modified; one half had a polyurethane cover with an occluded end and the other half was uncovered with a flaring configuration. The occluded end was placed such that it would face the distal lung. Under fluoroscopic guidance, seven stents were placed at the lower lobar bronchus in 6 mini-pigs. The bronchial obstruction was examined immediately after stent placement. Chest radiographs were taken at days 1, 7, 14, and 28 after stent placement and the removed airways from two, two, one, and one mini-pigs sacrificed on corresponding days were examined for the maintenance of bronchial obstruction. Stents were successfully placed and induced the immediate bronchial obstruction in all mini-pigs. Five of seven airways with occlusion stents maintained an obstruction until the mini-pigs were sacrificed. Proximal stent migration occurred in two mini-pigs (29%), and pulmonary consolidations were observed distal to four of the stents (57%). The placement of an endobronchial occlusion stent and the obstruction of targeted bronchi seem to be feasible, but an add-on check valve should be considered to prevent stent migration and obstructive pneumonia

  2. [Absorbable coronary stents. New promising technology].

    Science.gov (United States)

    Erbel, Raimund; Böse, Dirk; Haude, Michael; Kordish, Igor; Churzidze, Sofia; Malyar, Nasser; Konorza, Thomas; Sack, Stefan

    2007-06-01

    Coronary stent implantation started in Germany 20 years ago. In the beginning, the progress was very slow and accelerated 10 years later. Meanwhile, coronary stent implantation is a standard procedure in interventional cardiology. From the beginning of permanent stent implantation, research started to provide temporary stenting of coronary arteries, first with catheter-based systems, later with stent-alone technology. Stents were produced from polymers or metal. The first polymer stent implantation failed except the Igaki-Tamai stent in Japan. Newly developed absorbable polymer stents seem to be very promising, as intravascular ultrasound (IVUS) and optical coherence tomography have demonstrated. Temporary metal stents were developed based on iron and magnesium. Currently, the iron stent is tested in peripheral arteries. The absorbable magnesium stent (Biotronik, Berlin, Germany) was tested in peripheral arteries below the knee and meanwhile in the multicenter international PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting with Absorbable Metal Stents) study. The first magnesium stent implantation was performed on July 30, 2004 after extended experimental testing in Essen. The magnesium stent behaved like a bare-metal stent with low recoil of 5-7%. The stent struts were absorbed when tested with IVUS. Stent struts were not visible by fluoroscopy or computed tomography (CT) as well as magnetic resonance imaging (MRI). That means, that the magnesium stent is invisible and therefore CT and MRI can be used for imaging of interventions. Only using micro-CT the stent struts were visible. The absorption process could be demonstrated in a patient 18 days after implantation due to suspected acute coronary syndrome, which was excluded. IVUS showed a nice open lumen. Stent struts were no longer visible, but replaced by tissue indicating the previous stent location. Coronary angiography after 4 months showed an ischemia-driven target lesion

  3. A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.

    Science.gov (United States)

    Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K

    2012-06-01

    Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.

  4. Obesity and carotid artery remodeling

    DEFF Research Database (Denmark)

    Kozakova, M; Palombo, C; Morizzo, C

    2015-01-01

    BACKGROUND/OBJECTIVE: The present study tested the hypothesis that obesity-related changes in carotid intima-media thickness (IMT) might represent not only preclinical atherosclerosis but an adaptive remodeling meant to preserve circumferential wall stress (CWS) in altered hemodynamic conditions...... and CCA LD (266 healthy subjects with wide range of body weight (24-159 kg)); (B) longitudinal associations between CCA LD and 3-year IMT progression rate (ΔIMT; 571 healthy non-obese subjects without increased cardiovascular (CV) risk); (C) the impact of obesity on CCA geometry and CWS (88 obese subjects...... without CV complications and 88 non-obese subjects matched for gender and age). RESULTS: CCA LD was independently associated with SV that was determined by body size. In the longitudinal study, baseline LD was an independent determinant of ΔIMT, and ΔIMT of subjects in the highest LD quartile...

  5. Recurrence of Subacute Stent Thrombosis and In-Stent Restenosis during Five Months after Stent Implantation in the LAD. A Case Report.

    OpenAIRE

    島田, 弘英; 大和, 眞史; 櫻井, 俊平; 疋田, 博之; 池田, 修一

    2001-01-01

    A coronary stent was deployed in the left anterior descending artery of an 82-year-old woman with unstable angina.Recurrence of subacute stent thrombosis and in-stent restenosis occurred frequently during the five months after initial stent implantation.Balloon angioplasty and cutting balloon angioplasty failed to prevent these complications,but they ceased after re-stenting in the initial stent.In this case,tissue protrusion through the stent strut, deformation of the coil stent and inadequa...

  6. Predictors of stent dysfunction after self-expandable metal stent placement for malignant gastric outlet obstruction: tumor ingrowth in uncovered stents and migration of covered stents.

    Science.gov (United States)

    Hori, Yasuki; Naitoh, Itaru; Hayashi, Kazuki; Ban, Tesshin; Natsume, Makoto; Okumura, Fumihiro; Nakazawa, Takahiro; Takada, Hiroki; Hirano, Atsuyuki; Jinno, Naruomi; Togawa, Shozo; Ando, Tomoaki; Kataoka, Hiromi; Joh, Takashi

    2017-10-01

    Endoscopic metallic stenting is widely accepted as a palliation therapy for malignant gastric outlet obstruction (GOO). However, the predictors of stent dysfunction have not been clarified. We aimed to evaluate the predictors, especially tumor ingrowth in uncovered self-expandable metallic stents (U-SEMS) and migration of covered self-expandable metallic stents (C-SEMS), which are the main causes related to the stent characteristics. In this multicenter retrospective study, we compared patients with U-SEMS and C-SEMS in terms of clinical outcomes, and predictors of stent dysfunction. In total, 252 patients (126 with U-SEMS and 126 with C-SEMS) were enrolled. There were no significant differences in technical success, clinical success, GOO score, or time to stent dysfunction. Tumor ingrowth was significantly more frequent in U-SEMS (U-SEMS, 11.90% vs. C-SEMS, 0.79%; p = 0.002), and stent migration was significantly more frequent for C-SEMS (C-SEMS, 8.73% vs. U-SEMS, 0.79%; p = 0.005). Karnofsky performance status (p = 0.04), no presence of ascites (p = 0.02), and insufficient (stent expansion (p = 0.003) were significantly associated with tumor ingrowth in U-SEMS. Meanwhile, a shorter stent length (p = 0.05) and chemotherapy (p = 0.03) were predictors of C-SEMS migration. Both U-SEMS and C-SEMS are effective with comparable patencies. Tumor ingrowth and stent migration are the main causes of stent dysfunction for U-SEMS and C-SEMS, respectively. With regard to stent dysfunction, U-SEMS might be a good option for patients receiving chemotherapy, while C-SEMS with longer stents for patients in good condition. (Clinical trial registration number: UMIN000024059).

  7. Clinical experience in coronary stenting with the Vivant Z Stent.

    Science.gov (United States)

    Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H

    2005-06-01

    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.

  8. MR plaque imaging of the carotid artery

    International Nuclear Information System (INIS)

    Watanabe, Yuji; Nagayama, Masako

    2010-01-01

    Atherosclerotic carotid plaque represents a major cause of cerebral ischemia. The detection of vulnerable plaque is important for preventing future cardiovascular events. The key factors in advanced plaque that are most likely to lead to patient complications are the condition of the fibrous cap, the size of the necrotic core and hemorrhage, and the extent of inflammatory activity within the plaque. Magnetic resonance (MR) imaging has excellent soft tissue contrast and can allow for a more accurate and objective estimation of carotid wall morphology and plaque composition. Recent advances in MR imaging techniques have permitted serial monitoring of atherosclerotic disease evolution and the identification of intraplaque risk factors for accelerated progression. The purpose of this review article is to review the current state of techniques of carotid wall MR imaging and the characterization of plaque components and surface morphology with MR imaging, and to describe the clinical practice of carotid wall MR imaging for the determination of treatment plan. (orig.)

  9. Ophthalmic masquerades of the atherosclerotic carotids

    Directory of Open Access Journals (Sweden)

    Anupriya Arthur

    2014-01-01

    Full Text Available Patients with carotid atherosclerosis can present with ophthalmic symptoms. These symptoms and signs can be due to retinal emboli, hypoperfusion of the retina and choroid, opening up of collateral channels, or chronic hypoperfusion of the globe (ocular ischemic syndrome. These pathological mechanisms can produce many interesting signs and a careful history can bring out important past symptoms pointing toward the carotid as the source of the patient′s presenting symptom. Such patients are at high risk for an ischemic stroke, especially in the subsequent few days following their first acute symptom. It is important for clinicians to be familiar with these ophthalmic symptoms and signs caused by carotid atherosclerosis for making an early diagnosis and to take appropriate measures to prevent a stroke. This review elaborates the clinical features, importance, and implications of various ophthalmic symptoms and signs resulting from atherosclerotic carotid artery disease.

  10. A method to determine the kink resistance of stents and stent delivery systems according to international standards

    Directory of Open Access Journals (Sweden)

    Brandt-Wunderlich Christoph

    2016-09-01

    Full Text Available The kink behavior of vascular stents is of particular interest for clinicians, stent manufacturers and regulatory as a kinked stent generates a lumen loss in the stented vessel and can lead to in-stent restenosis. In this study methods to determine the kink resistance of stents and stent delivery systems according to the ISO 25539-2 and FDA guidance no. 1545 were presented. The methods are applicable for balloon expandable stents as well as for self-expanding stents and determine the lumen loss and residual diameter change dependent on the specific bending radius.

  11. Provider-Induced Demand in the Treatment of Carotid Artery Stenosis: Variation in Treatment Decisions Between Private Sector Fee-for-Service vs Salary-Based Military Physicians.

    Science.gov (United States)

    Nguyen, Louis L; Smith, Ann D; Scully, Rebecca E; Jiang, Wei; Learn, Peter A; Lipsitz, Stuart R; Weissman, Joel S; Helmchen, Lorens A; Koehlmoos, Tracey; Hoburg, Andrew; Kimsey, Linda G

    2017-06-01

    Although many factors influence the management of carotid artery stenosis, it is not well understood whether a preference toward procedural management exists when procedural volume and physician compensation are linked in the fee-for-service environment. To explore evidence for provider-induced demand in the management of carotid artery stenosis. The Department of Defense Military Health System Data Repository was queried for individuals diagnosed with carotid artery stenosis between October 1, 2006, and September 30, 2010. A hierarchical multivariable model evaluated the association of the treatment system (fee-for-service physicians in the private sector vs salary-based military physicians) with the odds of procedural intervention (carotid endarterectomy or carotid artery stenting) compared with medical management. Subanalysis was performed by symptom status at the time of presentation. The association of treatment system and of management strategy with clinical outcomes, including stroke and death, was also evaluated. Data analysis was conducted from August 15, 2015, to August 2, 2016. The odds of procedural intervention based on treatment system was the primary outcome used to indicate the presence and effect of provider-induced demand. Of 10 579 individuals with a diagnosis of carotid artery stenosis (4615 women and 5964 men; mean [SD] age, 65.6 [11.4] years), 1307 (12.4%) underwent at least 1 procedure. After adjusting for demographic and clinical factors, the odds of undergoing procedural management were significantly higher for patients in the fee-for-service system compared with those in the salary-based setting (odds ratio, 1.629; 95% CI, 1.285-2.063; P fee-for-service system were significantly more likely to undergo procedural management for carotid stenosis compared with those in the salary-based setting. These findings remained consistent for individuals with and without symptomatic disease.

  12. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  13. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Takumi, E-mail: higuma@cc.hirosaki-u.ac.jp; Abe, Naoki; Hanada, Kenji; Yokoyama, Hiroaki; Tomita, Hirofumi; Okumura, Ken

    2014-04-15

    A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.

  14. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

    Science.gov (United States)

    Lin, Jing; Guidoin, Robert; Du, Jia; Wang, Lu; Douglas, Graeham; Zhu, Danjie; Nutley, Mark; Perron, Lygia; Zhang, Ze; Douville, Yvan

    2016-02-16

    Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  15. Hemodynamic significance of internal carotid artery disease

    DEFF Research Database (Denmark)

    Schroeder, T

    1988-01-01

    Neurologic symptoms in the region of an internal carotid artery stenosis are considered to be embolic in most instances. Only in a subgroup has carotid occlusive disease with impairment of the collateral supply, caused a state of hemodynamic failure with marked reduction of perfusion pressure...... stenosis. This is considered a result of chronic low perfusion pressure with subsequent loss of autoregulation, and autoregulatory control is first regained after some days.(ABSTRACT TRUNCATED AT 400 WORDS)...

  16. Angiographic diagnosis of the carotid artery pseudoaneurysm

    International Nuclear Information System (INIS)

    Qi Yueyong; Zou Liguang; Dai Shuhua; Tan Yinghui; Li Zhongyu; Zhou Zheng

    2004-01-01

    Objective: To create a further understanding of the angiographic features of the carotid artery pseudoaneurysm (CAPA) and to explore the clinical diagnostic value of angiography. Methods: Sixteen cases of CAPA with clinical and angiographic data were analyzed retrospectively. The angiographic appearances in all of the patients were observed dynamically and precisely with a double blind method by two experienced radiologists together and formed a consensus interpretation. Results: Angiography provided a definite diagnosis for all cases. The parent arteries included the common carotid artery (1 case), common carotid artery bifurcation (9 cases), internal carotid artery (5 cases) and external carotid artery (1 case). The angiographic features of the CAPA were: All cases showed the contrast media retension in the aneurysms; turbulent flow within aneurysm in 9 cases; the 'jetting sign' at the leak of the parent artery in 7 cases; increase angulation of the bifurcation of internal and external carotid arteries in 12 cases. Conclusions: Angiography is the most valuable examination method in diagnosis of CAPA, and it can not only provide definite diagnosis, but also play an important role in selection of therapeutic plan. (authors)

  17. Carotid chemoreceptor development and neonatal apnea.

    Science.gov (United States)

    MacFarlane, Peter M; Ribeiro, Ana P; Martin, Richard J

    2013-01-01

    The premature transition from fetal to neonatal life is accompanied by an immature respiratory neural control system. Most preterm infants exhibit recurrent apnea, resulting in repetitive oscillations in O(2) saturation (intermittent hypoxia, IH). Numerous factors are likely to play a role in the etiology of apnea including inputs from the carotid chemoreceptors. Despite major advances in our understanding of carotid chemoreceptor function in the early neonatal period, however, their contribution to the initiation of an apneic event and its eventual termination are still largely speculative. Recent findings have provided a detailed account of the postnatal changes in the incidence of hypoxemic events associated with apnea, and there is anecdotal evidence for a positive correlation with carotid chemoreceptor maturation. Furthermore, studies on non-human animal models have shown that chronic IH sensitizes the carotid chemoreceptors, which has been proposed to perpetuate the occurrence of apnea. An alternative hypothesis is that sensitization of the carotid chemoreceptors could represent an important protective mechanism to defend against severe hypoxemia. The purpose of this review, therefore, is to discuss how the carotid chemoreceptors may contribute to the initiation and termination of an apneic event in the neonate and the use of xanthine therapy in the prevention of apnea. Published by Elsevier B.V.

  18. Angiographic patterns of carotid-cavernous fistulas

    International Nuclear Information System (INIS)

    Georgieva, G.; Jekova, M.; Genov, P.; Hadjidekov, V.

    2006-01-01

    Full text: The aim of the study is to present our experience in angiographic evaluation of carotid-cavernous fistulas. 8 patients with carotid-cavernous fistula (6 men and 2 women, range of age from 15 to 62) are included in the study out of all undergone cerebral angiography for a four year period (1996 - 2000). All patients underwent CT brain examination, two out of 8 - MRI. Visualization of ipsi- and contra lateral cavernous sinus and ophthalmic vein dilatation are assessed. In all cases the communication between the internal carotid artery and the cavernous sinus has been assessed as direct. Near simultaneous visualization of the home internal carotid artery, the dilated ipsilateral cavernous sinus and dilated superior ophthalmic vein is found in 2 patients, simultaneous visualization of both cavernous sinuses - in two. In 1 patient the early visualization of the cavernous sinus through the fistula enabled visualization of ipsilateral main internal carotid artery from the contra lateral circulation through the communicating arteries.In 1 excessive contralateral cavernous sinus and contralateral superior ophthalmic vein dilatation is detected. In other 1 excessive flow to dilated ipsilateral cavernous sinus lead insufficient circulation in distal vessels. Digital subtraction Angiography remains the most suitable imaging method in carotid-cavernous fistula assessment regarding type of communication and level of following vessels morphology changes

  19. Comparison of a New Polytetrafluoroethylene-Covered Metallic Stent to a Noncovered Stent in Canine Ureters

    International Nuclear Information System (INIS)

    Chung, Hwan-Hoon; Lee, Seung Hwa; Cho, Sung Bum; Park, Hong Suk; Kim, Young Sik; Kang, Byung Chul; Frisoli, Joan K.; Razavi, Mahmood K.

    2008-01-01

    The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted

  20. Polymeric Biodegradable Stent Insertion in the Esophagus

    Directory of Open Access Journals (Sweden)

    Kai Yang

    2016-04-01

    Full Text Available Esophageal stent insertion has been used as a well-accepted and effective alternative to manage and improve the quality of life for patients diagnosed with esophageal diseases and disorders. Current stents are either permanent or temporary and are fabricated from either metal or plastic. The partially covered self-expanding metal stent (SEMS has a firm anchoring effect and prevent stent migration, however, the hyperplastic tissue reaction cause stent restenosis and make it difficult to remove. A fully covered SEMS and self-expanding plastic stent (SEPS reduced reactive hyperplasia but has a high migration rate. The main advantage that polymeric biodegradable stents (BDSs have over metal or plastic stents is that removal is not require and reduce the need for repeated stent insertion. But the slightly lower radial force of BDS may be its main shortcoming and a post-implant problem. Thus, strengthening support of BDS is a content of the research in the future. BDSs are often temporarily effective in esophageal stricture to relieve dysphagia. In the future, it can be expect that biodegradable drug-eluting stents (DES will be available to treat benign esophageal stricture, perforations or leaks with additional use as palliative modalities for treating malignant esophageal stricture, as the bridge to surgery or to maintain luminal patency during neoadjuvant chemoradiation.

  1. Stent Design Affects Femoropopliteal Artery Deformation.

    Science.gov (United States)

    MacTaggart, Jason; Poulson, William; Seas, Andreas; Deegan, Paul; Lomneth, Carol; Desyatova, Anastasia; Maleckis, Kaspars; Kamenskiy, Alexey

    2018-03-23

    Poor durability of femoropopliteal artery (FPA) stenting is multifactorial, and severe FPA deformations occurring with limb flexion are likely involved. Different stent designs result in dissimilar stent-artery interactions, but the degree of these effects in the FPA is insufficiently understood. To determine how different stent designs affect limb flexion-induced FPA deformations. Retrievable markers were deployed into n = 28 FPAs of lightly embalmed human cadavers. Bodies were perfused and CT images were acquired with limbs in the standing, walking, sitting, and gardening postures. Image analysis allowed measurement of baseline FPA foreshortening, bending, and twisting associated with each posture. Markers were retrieved and 7 different stents were deployed across the adductor hiatus in the same limbs. Markers were then redeployed in the stented FPAs, and limbs were reimaged. Baseline and stented FPA deformations were compared to determine the influence of each stent design. Proximal to the stent, Innova, Supera, and SmartFlex exacerbated foreshortening, SmartFlex exacerbated twisting, and SmartControl restricted bending of the FPA. Within the stent, all devices except Viabahn restricted foreshortening; Supera, SmartControl, and AbsolutePro restricted twisting; SmartFlex and Innova exacerbated twisting; and Supera and Viabahn restricted bending. Distal to the stents, all devices except AbsolutePro and Innova exacerbated foreshortening, and Viabahn, Supera, Zilver, and SmartControl exacerbated twisting. All stents except Supera were pinched in flexed limb postures. Peripheral self-expanding stents significantly affect limb flexion-induced FPA deformations, but in different ways. Although certain designs seem to accommodate some deformation modes, no device was able to match all FPA deformations.

  2. Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.

    Science.gov (United States)

    Rafighdust, Abbasali; Eshraghi, Ali

    2015-10-27

    The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.

  3. Internal carotid artery rupture caused by carotid shunt insertion.

    Science.gov (United States)

    Illuminati, Giulio; Caliò, Francesco G; Pizzardi, Giulia; Vietri, Francesco

    2015-01-01

    Shunting is a well-accepted method of maintaining cerebral perfusion during carotid endarterectomy (CEA). Nonetheless, shunt insertion may lead to complications including arterial dissection, embolization, and thrombosis. We present a complication of shunt insertion consisting of arterial wall rupture, not reported previously. A 78-year-old woman underwent CEA combined with coronary artery bypass grafting (CABG). At the time of shunt insertion an arterial rupture at the distal tip of the shunt was detected and was repaired via a small saphenous vein patch. Eversion CEA and subsequent CABG completed the procedure whose postoperative course was uneventful. Shunting during combined CEA-CABG may be advisable to assure cerebral protection from possible hypoperfusion due to potential hemodynamic instability of patients with severe coronary artery disease. Awareness and prompt management of possible shunt-related complications, including the newly reported one, may contribute to limiting their harmful effect. Arterial wall rupture is a possible, previously not reported, shunt-related complication to be aware of when performing CEA. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Causes and prevention of in-stent restenosis of vertebral artery origin after stenting

    International Nuclear Information System (INIS)

    Zhao Huipin; Li Shenmao; Zhang Guangping

    2010-01-01

    Vertebral artery stenosis is an important cause of posterior circulation stroke. Vertebral artery stenosis most commonly occurs at its origin site. In recent years, balloon angioplasty and stent implantation have been widely employed in the treatment of vertebral artery origin stenosis. However, the long term outcome of stent implantation is affected by in-stent restenosis. Multiple contributory factors have been identified, but clear understanding of the overall underlying mechanism remains an enigma. With the development of pathophysiology, prevention and treatment methods of in-stent restenosis have been improved. In recent years, drug-eluting stents, radioactive stents and magnetic stents have been widely applied. To some extent, these stents and drug therapy can solve the problem of restenosis. This article aims to review the clinical application and the up-to-date research progresses in preventing and managing vertebral artery origin restenosis. (authors)

  5. Evaluation of a novel stent technology: the Genous EPC capturing stent

    NARCIS (Netherlands)

    Klomp, M.

    2012-01-01

    Tegenwoordig gebruiken ziekenhuizen een nieuwe stent bij dotterbehandelingen van kransslagadervernauwingen. Deze Genous-stent heeft een laag met antistoffen waardoor het behandelde bloedvat snel bedekt raakt met lichaamseigen cellen. Zo wordt tegengegaan dat er opnieuw een vernauwing optreedt of dat

  6. Comparison of self-expandable and balloon-expanding stents for hybrid ductal stenting in hypoplastic left heart complex.

    Science.gov (United States)

    Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J

    2017-07-01

    We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.

  7. Forgotten Ureteral Stents: An Avoidable Morbidity

    International Nuclear Information System (INIS)

    Murtaza, B.; Alvi, S.

    2016-01-01

    Objective: To assess the clinical presentation of forgotten ureteral stents and highlight the etiological factors resulting in the retention of these stents. Study Design: Observational study. Place and Duration of Study: Department of Urology, Armed Forces Institute of Urology, Rawalpindi, from January 2010 to Jun 2011. Methodology: Thirty-eight patients, with forgotten ureteral stents, retained for more than 6 months duration, were enrolled. A detailed evaluation was performed, along with the questions regarding the patients' opinion about the ureteral stents. They were specially asked whether they knew about the stents or were they formally informed regarding the stents. Subsequently, the patients were managed according to their clinical condition. Results: The male to female ratio was 2.1:1 aged 23 - 69 years, mean being 40.24 ± 12.59 years. The time of presentation after the ureteral stenting was 7 - 180 months (mean = 28.89 ± 33.435 years). Seven patients (18.4 percentage) reported with chronic kidney disease, including ESRD in two cases. Recurrent UTI was seen in 28 cases (73.6 percentage), calculus formed over the stents in 20 cases (52.6 percentage), and stent fragmented in 5 patients (13.1 percentage). Majority of patients, (n = 23, 60.5 percentage), were not even aware of the placement of these stents while 8 (21.0 percentage) knew but were reluctant about its removal. In 3 cases (7.8 percentage), the relatives knew about the stent but never informed the patients. The stent had been removed in 2 cases (5.2 percentage), but the other broken fragment was missed. One case (2.6 percentage) each had a misconception about the permanent placement of the stents like cardiac stents and regarding degradation of the stents in situ. Conclusion: Forgotten ureteral stents produce clinical features ranging from recurrent UTI to ESRD. This preventable urological complication is primarily due to the unawareness or ignorance of the patients and their relatives

  8. Early control of distal internal carotid artery during carotid endarterectomy: does it reduce cerebral microemboli?

    Science.gov (United States)

    Mommertz, G; Das, M; Langer, S; Koeppel, T A; Krings, T; Mess, W H; Schiefer, J; Jacobs, M J

    2010-06-01

    According to the results of the large trials on carotid endarterectomy (CEA), this type of surgery is only warranted if perioperative mortality and morbidity are kept considerably low. Less attention has been paid to methods of cerebral protection during CEA, although intraoperative transcranial Doppler (TCD) can visualise intracerebral microemboli (MES) during routine carotid dissection, although MES occur throughout the CEA, only those during dissection are related to neurological outcome. Prevention of MES by means of early control of the distal internal carotid artery dislodging from the carotid artery plaque during dissection is very likely the mechanism behind an eventual benefit from this approach. Hence, the amount of MES might serve as a surrogate parameter for the risk of periprocedural neurological events. So, the aim of the present study was to evaluate whether early control of the distal carotid artery during CEA is capable of reducing the number of MES by means of a prospective randomised trial. Twenty-eight patients (29 procedures) could be prospectively included in our study. Before surgery we randomly assigned the patients to two groups: group A (N.=12): CEA by means of early control of the distal internal carotid artery; group B (N.=17): CEA with dissection of the total carotid bifurcation before clamping the arteries. Periprocedurally, we continuously monitored the cerebral blood flow in the ipsilateral middle cerebral artery by means of TCD. Pre- and postoperative morbidity were independently verified by a neurologist control of the distal internal carotid artery did not reduce the occurrence of MES during dissection of the carotid bifurcation. Also, the total number of MES throughout the procedure and postoperatively was comparable between both groups. The procedure related times as well as the clinical outcome did not differ significantly. Thus, early control of the distal internal carotid artery has got no advantage but also no disadvantage

  9. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  10. Self-Expandable Metal Stents and Trans-stent Light Delivery: Are Metal Stents and Photodynamic Therapy Compatible?

    Science.gov (United States)

    Wang, Luo-Wei; Li, Li-Bo; Li, Zhao-Shen; Chen, Yang K; Hetzel, Fred W.; Huang, Zheng

    2008-01-01

    Background and Objectives: Obstructive non-small cell lung cancer and obstructive esophageal cancer are US FDA approved indications of photodynamic therapy (PDT). The usefulness of PDT for the treatment of cholangiocarcinoma is currently under clinical investigation. Endoscopic stenting for lumen restoration is a common palliative intervention for those indications. It is important to assess whether self-expandable metal stents are compatible with trans-stent PDT light delivery. Study Design/Materials and Methods: Direct effects of various components of metal biliary (n = 2), esophageal (n = 2), and bronchial (n = 1) stents on PDT light transmittance and distribution were examined using a point or linear light source (630 or 652 nm diode laser). Resected pig biliary duct and esophageal wall tissues were used to examine the feasibility of PDT light delivery through the fully expanded metal stents. Results: While using a point light source, the metal components (thread and joint) of the stent could cause a significant shadow effect. The liner material (polytetrafluoroethylene or polyurethane) could cause various degrees of light absorption. When the stent was covered with a thin layer of biliary duct and esophageal tissues containing all wall layers, the shadow effect could be mitigated due to tissue scattering. Conclusions: This study clearly demonstrates that it is feasible to combine stenting and PDT for the treatment of luminal lesions. PDT light dose should be adjusted to counteract the reduction of light transmittance caused by the metal and liner materials of stent. PMID:18951422

  11. Radiation-induced carotid artery atherosclerosis

    International Nuclear Information System (INIS)

    Gujral, Dorothy M.; Chahal, Navtej; Senior, Roxy; Harrington, Kevin J.; Nutting, Christopher M.

    2014-01-01

    Purpose: Carotid arteries frequently receive significant doses of radiation as collateral structures in the treatment of malignant diseases. Vascular injury following treatment may result in carotid artery stenosis (CAS) and increased risk of stroke and transient ischaemic attack (TIA). This systematic review examines the effect of radiotherapy (RT) on the carotid arteries, looking at the incidence of stroke in patients receiving neck radiotherapy. In addition, we consider possible surrogate endpoints such as CAS and carotid intima-medial thickness (CIMT) and summarise the evidence for radiation-induced carotid atherosclerosis. Materials and methods: From 853 references, 34 articles met the criteria for inclusion in this systematic review. These papers described 9 studies investigating the incidence of stroke/TIA in irradiated patients, 11 looking at CAS, and 14 examining CIMT. Results: The majority of studies utilised suboptimally-matched controls for each endpoint. The relative risk of stroke in irradiated patients ranged from 1.12 in patients with breast cancer to 5.6 in patients treated for head and neck cancer. The prevalence of CAS was increased by 16–55%, with the more modest increase seen in a study using matched controls. CIMT was increased in irradiated carotid arteries by 18–40%. Only two matched-control studies demonstrated a significant increase in CIMT of 36% and 22% (p = 0.003 and <0.001, respectively). Early prospective data demonstrated a significant increase in CIMT in irradiated arteries at 1 and 2 years after RT (p < 0.001 and <0.01, respectively). Conclusions: The incidence of stroke was significantly increased in patients receiving RT to the neck. There was a consistent difference in CAS and CIMT between irradiated and unirradiated carotid arteries. Future studies should optimise control groups

  12. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  13. Prevention of stent thrombosis: challenges and solutions

    Science.gov (United States)

    Reejhsinghani, Risheen; Lotfi, Amir S

    2015-01-01

    Stent thrombosis is an uncommon but serious complication which carries with it significant mortality and morbidity. This review analyzes the entity of stent thrombosis from a historical and clinical perspective, and chronicles the evolution of this condition through the various generations of stent development, from bare metal to first-generation, second-generation, and third-generation drug-eluting stents. It also delineates the specific risk factors associated with stent thrombosis and comprehensively examines the literature related to each of these risks. Finally, it highlights the preventative strategies that can be garnered from the existing data, and concludes that a multifactorial approach is necessary to combat the occurrence of stent thrombosis, with higher risk groups, such as patients with ST segment elevation myocardial infarction, meriting further research. PMID:25657588

  14. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Park, Hyungkeun

    2006-01-01

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8±42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  15. Genous endothelial progenitor cell-capturing stent system: a novel stent technology

    NARCIS (Netherlands)

    Klomp, Margo; Beijk, Marcel A. M.; de Winter, Robbert J.

    2009-01-01

    Drug-eluting stents have been demonstrated to significantly reduce clinical and angiographic restenosis in patients with coronary artery disease compared with bare-metal stents. Intuitively, however, a prohealing approach for the prevention of in-stent restenosis by promoting accelerated

  16. Mechanical behavior of peripheral stents and stent-vessel interaction: A computational study

    Science.gov (United States)

    Dottori, Serena; Flamini, Vittoria; Vairo, Giuseppe

    2016-05-01

    In this paper stents employed to treat peripheral artery disease are analyzed through a three-dimensional finite-element approach, based on a large-strain and large-displacement formulation. Aiming to evaluate the influence of some stent design parameters on stent mechanics and on the biomechanical interaction between stent and arterial wall, quasi-static and dynamic numerical analyses are carried out by referring to computational models of commercially and noncommercially available versions of both braided self-expandable stents and balloon-expandable stents. Addressing isolated device models, opening mechanisms and flexibility of both opened and closed stent configurations are numerically experienced. Moreover, stent deployment into a stenotic peripheral artery and possible postdilatation angioplasty (the latter for the self-expandable device only) are simulated by considering different idealized vessel geometries and accounting for the presence of a stenotic plaque. Proposed results highlight important differences in the mechanical response of the two types of stents, as well as a significant influence of the vessel shape on the stress distributions arising upon the artery-plaque system. Finally, computational results are used to assess both the stent mechanical performance and the effectiveness of the stenting treatment, allowing also to identify possible critical conditions affecting the risk of stent fracture, tissue damage, and/or pathological tissue response.

  17. PulmoStent : In Vitro to In Vivo Evaluation of a Tissue Engineered Endobronchial Stent

    NARCIS (Netherlands)

    Thiebes, Anja Lena; Kelly, Nicola; Sweeney, Caoimhe A.; McGrath, Donnacha J.; Clauser, Johanna; Kurtenbach, Kathrin; Gesche, Valentine N.; Chen, Weiluan; Kok, Robbert Jan; Steinseifer, Ulrich; Bruzzi, Mark; O’Brien, Barry J.; McHugh, Peter E.; Jockenhoevel, Stefan; Cornelissen, Christian G.

    Currently, there is no optimal treatment available for end stage tumour patients with airway stenosis. The PulmoStent concept aims on overcoming current hurdles in airway stenting by combining a nitinol stent with a nutrient-permeable membrane, which prevents tumour ingrowth. Respiratory epithelial

  18. Removal of retrievable self-expandable urethral stents: experience in 58 stents

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon; Song, Ho-Young; Kim, Jin Hyoung; Ko, Heung-Kyu; Kim, Yong Jae; Woo, Chul-Woong; Kim, Tae-Hyung; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Park, Hyungkeun [Asan Medical Center, Department of Urology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-09-15

    The purpose of this study was to retrospectively evaluate the safety and efficacy of removing retrievable self-expandable urethral stents using a retrieval hook wire. Under fluoroscopic guidance, the removal of 58 polyurethane or PTFE (polytetrafluoroethylene)-covered stents was attempted in 33 patients using a retrieval hook wire. Indications for removal were elective removal (n=21), stent migration (n=19), formation of tissue hyperplasia around or inside of the stent (n=14), stent deformity (n=3), and severe pain (n=1). The mean time the stents remained in place was 64.8{+-}42.9 days (range, 1-177 days). Fifty-six (97%) of the 58 stents were successfully removed using the retrieval hook wire despite the following difficulties; hook wire disconnection (n=2), untied drawstrings (n=3), and polyurethane membrane disruption/separation (n=4). The removal procedure using a retrieval hook wire failed in two stents (3%) which had migrated into the urinary bladder. One of the two stents with migration into the urinary bladder was removed using a snare through the cystostomy route. The overall complication rate was 14% (seven hematuria cases and one urethral tear case), and all were minor and spontaneously resolved without further treatment. In conclusion, removal of retrievable urethral stents using a retrieval hook wire was safe and effective despite some technical difficulties. It is a useful method for allowing temporary stent placement and solving various complications of stent use. (orig.)

  19. Complication after self expandable metallic stent for esophageal cancer

    International Nuclear Information System (INIS)

    Nagahama, Takeshi; Maruyama, Michio; Kato, Kiyomi; Shinoura, Hiroshi; Hasegawa, Kumi; Takashima, Itaru; Ebuchi, Masakazu

    2003-01-01

    Major complications after placement of esophageal stent and airway stent were reviewed and evaluated. Four patients, including two patients with perforations and two patients with fistula formation, developed major complications after placement of a self expandable metallic stent. Two patients underwent additional radiation to improve stricture after stent placement. In one patient, stent placement was selected to improve esophageal stricture that occurred after radical radiation therapy. In one patient, migration of stent into the lesion caused a perforation. It can be concluded that additional radiation after stent placement increases the risk of complication. Stent migration also can lead to the risk of perforation. (author)

  20. Distribution of C-myc Antisense Oligonucleotides in Rabbits after Local Delivery by Implanted Gelatin Coated Piatinium -iridium Stent

    Institute of Scientific and Technical Information of China (English)

    张新霞; 庞志功; 崔长琮; 许香广; 胡雪松; 方卫华

    2003-01-01

    Objectives To assess the feasibility, efficiency and tissue distribution of localdelivered c - myc antisense oligonucleotides (ASODN)by implanted gelatin coated Platinium- Iridium (Pt-Ir) stent. Methods Gelatin coated Pt- Ir stentwhich absorbed carboxyfluorescein - 5 - succimidylester (FAM) labeled c -myc ASODN were implantedin the right carotid arteries of 6 rabbits under vision.Blood samples were collected at the indicated times.The target artery、 left carotid artery、 heart、 liver andkidney obtained at 45 minutes、 2 hours and 6hours. The concentration of c - myc ASODN in plasmaand tissues were determined by Thin Layer Fluorome-try. Tissue distribution of c- myc ASODN were as-sessed by fluorescence microscopy. Results At 45min, 2 h, 6 h, the concentration of FAM labeled c -myc ASODN in target artery was 244.39, 194.44,126.94(μg/g tissues) respectively, and the deliveryefficiency were 44.4% 、 35.4% and 23.1% respec-tively. At the same indicated time point, the plasmaconcentration was 8.41, 5. 83, 14.75 (μg/ml) respec-tively. Therefore c -myc ASODN concentrations in thetarget vessel were 29、 33 and 9 -fold higher than thatin the plasma. There was circumferential distribution oflabeled c -myc in the area of highest fluorescein co-inciding with the site of medial dissecting from stent-ing, and the label was most intense in target vesselmedia harvested at 45 min time point and then dis-persed to adventitia. Conclusions Gelatin coated Pt- Ir stent mediated local delivery of c - myc ASODN isfeasible and efficient. The localization of ASODN ismainly in target vessel wall.

  1. The current role of vascular stents.

    Science.gov (United States)

    Busquet, J

    1993-09-01

    The limitations of percutaneous balloon angioplasty have favoured the development and the use of vascular endoprostheses or stents. These thin-walled metal devices maintain after expansion, an optimal and constant diameter for the vascular lumen. Restenosis, dissection, abrupt closure, residual stenosis or re-opened total occlusion represent appropriate indications for stenting. A large experience with non-coronary application of stents is currently available in iliac, femoro-popliteal and renal arteries, aorta, large veins.

  2. Stent implantation influence wall shear stress evolution

    Science.gov (United States)

    Bernad, S. I.; Totorean, A. F.; Bosioc, A. I.; Petre, I.; Bernad, E. S.

    2016-06-01

    Local hemodynamic factors are known affect the natural history of the restenosis critically after coronary stenting of atherosclerosis. Stent-induced flows disturbance magnitude dependent directly on the strut design. The impact of flow alterations around struts vary as the strut geometrical parameters change. Our results provide data regarding the hemodynamic parameters for the blood flow in both stenosed and stented coronary artery under physiological conditions, namely wall shear stress and pressure drop.

  3. Carotid Atherosclerosis and Cognitive Impairment in Nonstroke Patients

    Directory of Open Access Journals (Sweden)

    Wei-Hong Chen

    2017-01-01

    Conclusions: Carotid atherosclerosis can be used to predict the risk of cognitive impairment. Furthermore, diagnosing and treating carotid atherosclerosis at early stage might help clinicians prevent and treat vascular cognitive impairment in nonstroke patients.

  4. Management of JJ stent-related symptoms.

    Science.gov (United States)

    Papatsoris, Athanasios; Dellis, Athanasios; Daglas, George; Sanguedolce, Francesco

    2014-01-01

    Ureteric JJ stents are inserted in numerous pa- tients as a routine procedure. Nevertheless, the ideal JJ stent that does not cause any lower urinary tract symptoms has not been developed yet. Even special validated ques- tionnaires have been used for the assessment of JJ stent-related symtoms. For the management of such symtoms usually alpha-blockers are admin- istered. Also, studies have examined the efficacy and safety of anticholinergics and calcium channel blo- ckers. In this article we review the literature upon the management of JJ stent-related symptoms.

  5. Configuration affects parallel stent grafting results.

    Science.gov (United States)

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31

  6. Acute Stroke and Obstruction of the Extracranial Carotid Artery Combined with Intracranial Tandem Occlusion: Results of Interventional Revascularization

    International Nuclear Information System (INIS)

    Lescher, Stephanie; Czeppan, Katja; Porto, Luciana; Singer, Oliver C.; Berkefeld, Joachim

    2015-01-01

    PurposeDue to high thrombus load, acute stroke patients with tandem obstructions of the extra- and intracranial carotid arteries or the middle cerebral artery show a very limited response to systemic thrombolysis. Interventional treatment with mechanical thrombectomy—often in combination with acute stenting of underlying atherosclerotic stenosis or dissection—is increasingly used. It has been shown that such complex interventions are technically feasible. The lack of optimal management strategies and clinical data encouraged us to review our acute stroke interventions in patient with anterior circulation tandem lesions to determine lesion patterns, interventional approaches, and angiographic or clinical outcomes.Patients and MethodsWe retrospectively analyzed a series of 39 consecutive patients with intracranial vessel occlusion of the anterior circulation simultaneously presenting with high-grade cervical internal carotid artery (ICA) stenosis or occlusion.ResultsEmergency ICA stent implantation was technically feasible in all patients, and intracranial recanalization with TICI ≥ 2b was reached in a large number of patients (64 %). Good clinical outcomes (mRS ≤ 2 at 3 months) were achieved in one third of the patients (36 %). Symptomatic hemorrhages occurred in four patients (10 %). Mortality was 10 %.ConclusionEndovascular recanalization of acute cervical carotid artery occlusion was technically feasible in all patients, and resulted in high extra- and intracranial revascularization rates. A trend for favorable clinical outcome was seen in a higher TICI score, younger age, good collateral status, and combined IV rTPA and endovascular therapy

  7. Cardiac risk assessment before carotid endarterectomy

    International Nuclear Information System (INIS)

    Rabee, Hussein M.M.

    2000-01-01

    Preoperative cardiac assessment is an essential step to identify the patients at risk, optimize any dysfunction, anticipate perioperative and postoperative problems and plan special management. Carotid endarterectomy (CEA) has become one of the most commonly performed vascular procedures in Western countries. The awareness of the potential beneficial role and hazards of CEA is not proportionate to the magnitude of this problem in our countries, not only among patients, but also among the medical disciplines. This report is a retrospective analysis of the prevalence of coronary artery diseases among 442 patients who were referred to the Division of Vascular Surgery at the King Khalid University Hospital in Riyadh, Saudi Arabia with suspicion of carotid artery disease. Eighty-two patients proved to have significant carotid artery stenosis and had thorough preoperative cardiac assessment by senior cardiologist. All cases had clinical assessment and ECG, 66 cases had echocardiogram examination, 44 had Dipyridamole Thallium-scan and 12 had coronary angiogram. Sixty-eight patients underwent 76 carotid endarterectomy. Four of them had MI and only one case died during preoperative period. This study shows that cardiac screening studies have a potential role in the candidates for carotid surgery in influencing the decision to operate and intensify of perioperative monitoring and care. We believe that the teamwork should involve vascular surgeons, cardiologist and anesthetist to manage such critical patients properly. (author)

  8. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  9. Predictive Factors of In-Stent Restenosis in Renal Artery Stenting: A Retrospective Analysis

    International Nuclear Information System (INIS)

    Vignali, Claudio; Bargellini, Irene; Lazzereschi, Michele; Cioni, Roberto; Petruzzi, Pasquale; Caramella, Davide; Pinto, Stefania; Napoli, Vinicio; Zampa, Virna; Bartolozzi, Carlo

    2005-01-01

    Purpose. To retrospectively evaluate the role of clinical and procedural factors in predicting in-stent restenosis in patients with renovascular disease treated by renal artery stenting. Methods. From 1995 to 2002, 147 patients underwent renal artery stenting for the treatment of significant ostial atherosclerotic stenosis. Patients underwent strict clinical and color-coded duplex ultrasound follow-up. Ninety-nine patients (111 stents), with over 6 months of continuous follow-up (mean 22±12 months, range 6-60 months), were selected and classified according to the presence (group A, 30 patients, 32 lesions) or absence (group B, 69 patients, 79 lesions) of significant in-stent restenosis. A statistical analysis was performed to identify possible preprocedural and procedural predictors of restenosis considering the following data: sex, age, smoking habit, diabetes mellitus, hypertension, serum creatinine, cholesterol and triglyceride levels, renal artery stenosis grade, and stent type, length and diameter. Results. Comparing group A and B patients (χ 2 test), a statistically significant relation was demonstrated between stent diameter and length and restenosis: the risk of in-stent restenosis decreased when the stent was ≥6 mm in diameter and between 15 and 20 mm in length. This finding was confirmed by multiple logistic regression analysis. Stent diameter and length were proved to be significantly related to in-stent restenosis also when evaluating only patients treated by Palmaz stent (71 stents). Conclusion. Although it is based on a retrospective analysis, the present study confirms the importance of correct stent selection in increasing long-term patency, using stents of at least 6 mm in diameter and with a length of approximately 15-20 mm

  10. Radiation-Induced Carotid Artery Stenosis in a Patient with Carcinoma of the Oral Floor

    Directory of Open Access Journals (Sweden)

    Kahori Seto

    2013-01-01

    Full Text Available Radiation-induced carotid artery stenosis (RI-CS, a life-threatening condition, can occur after external radiation for head and neck cancer. We here describe a case of asymptomatic RI-CS in a 73-year-old patient treated with chemoradiotherapy and radical neck dissection for a basaloid squamous cell carcinoma of the oral floor. Stenosis of the left carotid artery, diagnosed as RI-CS, showed on an MRI performed 1.5 years after radiotherapy. Blood from the left side of the anterior cerebral artery and the middle anterior artery was flowing to the brain through the anterior and posterior communicating arteries, so no stent surgery or other treatment was necessary. The cancer has not recurred during approximately 5 years of followup after radiotherapy, and the patient has had no adverse effects from the RI-CS since it was diagnosed 3.5 years ago. This case emphasizes the necessity of early scrutiny for RI-CS in patients given radiotherapy for oral cancer.

  11. A Rare Diabetic Autonomic Neuropathy: Carotid Sinus Hypersensitivity

    Directory of Open Access Journals (Sweden)

    Ahmet Kaya

    2016-03-01

    Full Text Available Carotid sinus hypersensitivity is a common cause of fainting and falls in the elderly, and can be diagnosed by carotid sinus massage. We present a 67-year-old diabetic man who was admitted with hyperglycemia. During thyroid examination, clouding of consciousness occurred with unilateral palpation. Asystole was documented for 4.8 seconds and suspected for 7 seconds upon carotid sinus massage. A cardioverter defibrillator was implanted. Carotid sinus hypersensitivity should be kept in mind when examining diabetic patients.

  12. Costs of secondary prevention of stroke by carotid endarterectomy

    DEFF Research Database (Denmark)

    Hædersdal, Carsten; Sørensen, Mette; Olsen, Tom Skyhøj

    2012-01-01

    We estimated the costs to the Danish National Health Service of preventing stroke due to carotid artery stenosis by carotid endarterectomy (CEA), including costs of identifying patients, Doppler ultrasound (DUS) examination and CEA.......We estimated the costs to the Danish National Health Service of preventing stroke due to carotid artery stenosis by carotid endarterectomy (CEA), including costs of identifying patients, Doppler ultrasound (DUS) examination and CEA....

  13. Role of carotid duplex imaging in carotid screening programmes – an overview

    Directory of Open Access Journals (Sweden)

    Gillard Jonathan H

    2008-07-01

    Full Text Available Abstract Background Stroke is the third most common cause of death in the UK and the largest single cause of severe disability. Each year more than 110,000 people in England suffer from a stroke which costs the National Health Service (NHS over GBP2.8 billion. Thus, it is imperative that patients at risk be screened for underlying carotid artery atherosclerosis. Aim To assess the role of carotid ultrasound in different carotid screening programmes. Methods A literature overview was carried out by using PubMed search engine, to identify different carotid screening programmes that had used ultrasound scan as a screening tool. Results It appears that the carotid ultrasound is an effective method for screening carotid artery disease in community as it effectively predicts the presence of stenosis with high accuracy. There is a need for primary care to recommend high risk patients for regular screening, to reduce stroke and transient ischemic attack (TIA related morbidity and mortality. Conclusion Screening programmes using carotid ultrasonography contribute to public health awareness and promotion which in long term could potentially benefit in disease prevention and essentially promote better standards of healthcare.

  14. Endovascular management of a carotid aneurysm into the sphenoid sinus presenting with epistaxis.

    Science.gov (United States)

    Akkari, Mohamed; Gascou, Grégory; Trévillot, Vincent; Bonafé, Alain; Crampette, Louis; Machi, Paolo

    2015-12-01

    Non-traumatic cavernous internal carotid artery (ICA) aneurysms are rare, and favour the occurrence of massive recurrent epistaxis, which is associated with a high mortality rate. We report the case of a 67-year-old woman presenting a ruptured ICA aneurysm extending into the sphenoid sinus, revealed by epistaxis. Selective coil embolization of the aneurysm was performed. Flow-diverter stents were deployed in order to utterly exclude the aneurysm and prevent revascularization. Anti-platelet treatment was provided to lower the risk of in-stent thrombosis. A left frontal hematoma associated with a subarachnoid haemorrhage occurred at day 2. Outcome was favourable with no neurological sequelae, and no clinical recurrence of epistaxis occurred. A 4 months follow-up digital subtraction angiography showed a complete exclusion of the aneurysm. In addition, a magnetic resonance cerebral angiography at 16 months showed stable results. Thus, this two-stage endovascular procedure has proven its effectiveness in preventing epistaxis recurrence while preserving the ICA patency. © The Author(s) 2015.

  15. [Risk factors of rupture of internal carotid artery during surgical resection of carotid body tumor].

    Science.gov (United States)

    Li, Y H; Wang, J S; Yao, C; Chang, G Q; Yin, H H; Li, S Q; Lü, W M; Hu, Z J; Wang, S M

    2017-06-13

    Objective: To investigate risk factors of rupture of internal carotid artery resection during carotid body tumor resection and to summarize our treatment experience. Methods: During the period from 1991 to 2016, rupture of internal carotid artery occurred in 27 patients (28 tumors) during surgical resection of carotid body tumor in the First Affiliated Hospital of Sun Yat-sen University. Their clinical and follow-up data were retrospectively collected and analyzed. For all patients underwent surgical resection during this period, Logistic regression analysis was used to investigate the risk factors of intraoperative rupture of internal carotid artery. Results: Of these 28 tumors, there were 15 (53.6%) tumors with diameter≥5 cm and 20 (71.4%) Shamblin Ⅲ tumors. Intraoperatively, shunt was applied for 8 (28.6%) cases. Thirteen (46.4%) patients underwent ligation of external carotid artery, while 2 (7.1%) patients accepted resection of cranial nerves. Direct closure/patchplasty, autologous vessels or graft reconstruction was used in 16, 10 and 2 cases, respectively. Postoperatively, stroke occurred in 4(14.3%) cases and cranial nerve deficit in 15 (53.6%) cases. During a median length of 36 (14-125) months, cranial nerve deficit persisted in 5 cases. Follow-up radiologic examination indicated 3 (10.7%) cases of targeted vessel occlusion. However, no new-onset stroke was identified. Among all patients underwent surgical resection of carotid body tumor, female ( OR =3.650, P =0.012), age≤25 years old ( OR =3.710, P =0.013) and Shamblin Ⅲ tumor ( OR =4.631, P =0.008) increase the risks of intraoperative carotid artery rupture. Conclusions: Shamblin Ⅲ tumor is the predictor of rupture of internal carotid artery. Intraoperative, properly increased blood pressure, intraoperative heparinization and use of shunt for those cases without well-compensated cranial collateral arteries are likely to decreasing the incidence of stroke.