WorldWideScience

Sample records for transarterial microcatheter glue

  1. Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Uchikawa, Yoko; Mori, Kensaku; Shiigai, Masanari; Konishi, Takahiro; Hoshiai, Sodai; Ishigro, Toshitaka; Hiyama, Takashi; Nakai, Yasunobu; Minami, Manabu

    2015-01-01

    PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed the complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries

  2. Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Uchikawa, Yoko, E-mail: jauchikawa@gmail.com [University of Tsukuba Hospital, Department of Radiology (Japan); Mori, Kensaku, E-mail: moriken@md.tsukuba.ac.jp [University of Tsukuba, Department of Radiology, Faculty of Medicine (Japan); Shiigai, Masanari, E-mail: m-41gai@yahoo.co.jp [Tsukuba Medical Center Hospital, Department of Radiology (Japan); Konishi, Takahiro, E-mail: soratobukangaruu@gmail.com [University of Tsukuba Hospital, Department of Radiology (Japan); Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp [Ibaraki Prefectural Central Hospital, Department of Radiology (Japan); Ishigro, Toshitaka, E-mail: suzutokei@gmail.com; Hiyama, Takashi, E-mail: med-tak@hotmail.com [University of Tsukuba Hospital, Department of Radiology (Japan); Nakai, Yasunobu, E-mail: nakaiya@tmch.or.jp [Tsukuba Medical Center Hospital, Department of Neurosurgery (Japan); Minami, Manabu, E-mail: mminami@md.tsukuba.ac.jp [University of Tsukuba, Department of Radiology, Faculty of Medicine (Japan)

    2015-10-15

    PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed the complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.

  3. Transarterial microcatheter glue embolization of the bronchial artery for life-threatening hemoptysis: Technical and clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Baltacioglu, Feyyaz [Marmara University School of Medicine, Department of Radiology, Istanbul (Turkey)], E-mail: fbaltaci@yahoo.com; Cimsit, Nuri Cagatay [Marmara University School of Medicine, Department of Radiology, Istanbul (Turkey)], E-mail: cagataycimsit@gmail.com; Bostanci, Korkut [Marmara University School of Medicine, Department of Thoracic Surgery, Istanbul (Turkey)], E-mail: kbostanci@marmara.edu.tr; Yueksel, Mustafa [Marmara University School of Medicine, Department of Thoracic Surgery, Istanbul (Turkey)], E-mail: myuksel@marmara.edu.tr; Kodalli, Nihat [Marmara University School of Medicine, Department of Radiology, Istanbul (Turkey)], E-mail: nihatkodalli@yahoo.com

    2010-02-15

    Objectives: To report our experience with transarterial glue embolization of the bronchial artery for life-threatening hemoptysis. Materials and methods: Twenty-five patients underwent bronchial artery embolization, using coaxial microcatheter technique, with a liquid agent, n-butyl-2-cyanoacrylate (NBCA), named glue, for life-threatening hemoptysis. The technical and clinical outcomes were followed in terms of immediate control of bleeding, recurrence of hemoptysis and complications of the procedure. Results: Four patients had acute hemoptysis when they were evaluated. The average number of arteries embolized per patient was 2.9. BAEs were successful in controlling hemoptysis immediately in all 25 patients (100%) and in 24 patients (96%) at 1 month follow-ups. One patient had recurrent hemoptysis on the tenth day after embolization. The follow-up time ranged from 2 to 63 months (mean 14 months). Six patients (25%) died all as a result of their disease process. Bleeding recurred in 3 patients after 30 days (7th, 11th, 12th months). One patient had vomitting attacks with dysphagia after the procedure that lasted 24 h. Three patients had transient thoracic pain lasting 3-5 days. There were no procedure related spinal or vascular complications. Conclusions: Glue embolization with microcatheter technique is a safe and effective treatment in cases of life-threatening hemoptysis with a very high rate of success and low rate of complications.

  4. TRANS-ARTERIAL EMBOLIZATION WITH N-BUTYL CYANOACRYLATE GLUE FOR RENAL BLEEDING: Case Report

    Directory of Open Access Journals (Sweden)

    Benny Young

    2014-08-01

    Full Text Available Background: The objectivity in management of renal bleeding is to preserve a significant renal parenchyma tissue and prevent associated morbidities like anemic shock or renal impairment from substantial nephron demise or obstructed uropathy. Trans-arterial embolization therapy by interventional radiology offers a high success rate with potential of reserving normal renal tissue. The selection material for renal arterial embolization largely depends on vasculature anatomy and end-point of procedure. N-butyl cyanoacrylate glue in our experience is applied in lesion supplied by small size of end-artery. 

  5. Transarterial Embolization With Cyanoacrylate for Severe Arterioportal Shunt Complicated by Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shi Haibin, E-mail: shihb@vip.sina.com; Yang Zhengqiang; Liu Sheng; Zhou Weizhong; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun [First Affiliated Hospital of Nanjing Medical University, Department of Radiology (China)

    2013-04-15

    To evaluate the efficacy and safety of cyanoacrylate glue embolization in the treatment of severe arterioportal shunt (APS) presenting with hepatofugal portal venous flow in hepatocellular carcinoma (HCC) patients. Between July 2000 and January 2010, 27 HCC patients with severe APS presenting with hepatofugal portal venous flow underwent transarterial angiography and treatment. Among them, four patients were excluded from the study. Twelve patients underwent transarterial chemoperfusion and embolization of APS with cyanoacrylate glue between January 2006 and January 2010 (Emb group), and the other 11 patients undergoing only transarterial chemoperfusion without embolization of APS between July 2000 and December 2005 served as a control group (non-Emb group). The change of APS, survival rates, and procedure related complications were analyzed. In the Emb group, APS was improved in all of the 12 patients after initial glue embolization; long-term APS improvement with hepatopetal portal flow was achieved in 80 % (8 of 10) patients who underwent follow-up angiography. Survival rates in the Emb group were 67 % at 6 months, 33 % at 1 year, and 8 % at 2 years, whereas those in the non-Emb group were 0 % at 6 months (P < 0.05). Median survival time in the Emb group was 275 days, which was longer than that of 107 days in the non-Emb group (P = 0.001). There were no major complications in both groups. The preliminary experience suggests that glue embolization may be an effective and safe therapy in the management of severe APS accompanied by HCC and also improve patient survival.

  6. The accessory super-selective techniques in performing the transarterial embolization of intracranial dural arteriovenous fistulas

    International Nuclear Information System (INIS)

    Zhao Wenyuan; Liu Jianmin; Li Qiang; Fang Yibin; Xu Yi; Hong Bo; Huang Qinghai

    2010-01-01

    Objective: To evaluate the assistant techniques in performing transarterial embolization of intracranial dural arteriovenous fistulas (DAVF) when routine super-selective catheterization with microcatheter fails. Methods: Temporary balloon occlusion of the parent artery was adopted in 4 cases of anterior fossa DAVF and in one case of tentorial DAVF, and permanent occlusion of the distal main trunk with coils was carried out in one tentorial DAVF in order to help the super-selective catheterization. Results: The microcatheter was successfully advanced to, or near, the nidus with the help of these assistant techniques and all 6 cases were cured with single session. After the surgery no operation-related complications occurred. Conclusion: Our preliminary results indicate that the assistant techniques, including temporary balloon occlusion of the parent artery and permanent occlusion of the distal main trunk with coils, are a safe and effective method which can reliably help the successful performance of microcatheter catheterization, it can be safely used in complex cases when routine super-selective catheterization fails. (authors)

  7. Transarterial embolization for postoperative massive hemorrhage in patients with abdominal tumors

    International Nuclear Information System (INIS)

    Wang Zhiwei; Shi Haifeng; Sun Hao; Zhou Kang; Li Xiaoguang; Pan Jie; Zhang Xiaobo; Liu Wei; Yang Ning; Jin Zhengyu

    2010-01-01

    Objective: To discuss the feasibility and effectiveness of transarterial embolization for the management of postoperative massive hemorrhage in patients with abdominal tumors. Methods: Between January 2004 and December 2009 in authors' hospital transarterial embolization for postoperative massive hemorrhage was performed in thirteen patients with abdominal tumors. The clinical data and the technical points were retrospectively analyzed. Results: Of 13 patients,the bleeding was completely controlled in 10 after single embolization procedure. Re-bleeding occurred in the other 3 patients, and angiography showed the new bleeding arteries. Trans arterial embolization was carried out again, and the bleeding was successfully stopped in 2 patients. The remaining one patient had to be treated with surgery as the microcatheter could not be super-selectively placed into the bleeding vessel. The overall clinical success rate of trans arterial embolization for postoperative massive hemorrhage was 92% (12 /13). No severe complications occurred. Conclusion: Trans arterial embolization is a safe and effective treatment for postoperative massive hemorrhage in patients with abdominal tumors. (authors)

  8. Microcatheter embolization of hemorrhages

    International Nuclear Information System (INIS)

    Seppaenen, Seppo K.; Leppaenen, Martti J.; Pimenoff, Georg; Seppaenen, Janne M.

    1997-01-01

    Purpose. To evaluate the efficacy of embolotherapy using microcatheters in patients with hemorrhage from various locations. Methods. Among 29 patients there were 13 with severe epistaxis, 7 with gastrointestinal bleeding, 4 with hemorrhage in the kidney, 4 with bleeding in pelvic organs and 1 with bleeding in the shoulder region. In all cases, a Tracker-18 or Tracker-10 microcatheter was advanced coaxially through a 4.1 Fr guiding catheter in order to reach the bleeding site as distally as possible. Polyvinyl alcohol microparticles and/or platinum microcoils were used as embolic material. Results. The bleeding was stopped in 90% (26 of 29) of cases. In 66% of cases the treatment was curative, in 7% preoperative, and in 17% palliative. There were 3 clinical failures. Conclusion. Microcatheter embolization is an effective and safe means of managing different kinds of hemorrhage of various causes from a variety of sites

  9. Successful management with glue injection of arterial rupture seen during embolization of an arteriovenous malformation using a flow-directed catheter: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jong Won; Baik, Seung Kug; Shin, Mi Jung; Choi, Han Yong; Kim, Bong Gi [Wallace Memorial Baptist Hospital, Pusan (Korea, Republic of)

    2000-12-01

    We present a case in which an arterial rupture occurring during embolization of an arteriovenous malformation of the left occipital lobe with a flow-directed micro-catheter, was successfully sealed with a small amount of glue. We navigated a 1.8-Fr Magic catheter through the posterior cerebral artery, and during superselective test injection, extravasation was observed at the parieto-occipital branch. The catheter was not removed and the perforation site was successfully sealed with a small amount of glue injected through the same catheter. Prompt recognition and closure of the perforation site is essential for good prognosis. (author)

  10. Experimental circumferential canaloplasty with a new Schlemm canal microcatheter

    Directory of Open Access Journals (Sweden)

    Mao-Song Xie

    2018-01-01

    Full Text Available AIM: To present a new, simple, inexpensive Schlemm canal microcatheter for circumferential canaloplasty in a rabbit model. METHODS: A rabbit glaucoma animal model was established by intravitreal injection of triamcinolone acetonide. Circumferential canaloplasty with a new Schlemm canal microcatheter (patent license number: 201220029850.0 was performed. The Schlemm canal microcatheter was composed of microcatheter wall and lumen. The wall was made of high refractive index plastic optical fiber that could be attached to an illuminant so that the whole lighted microcatheter was visible during circumferential canaloplasty. The lumen could be attached to an injector for injection of viscoelastic during catheterization. Rabbits were divided randomly into the control, model and treatment groups. Intraocular pressure (IOP was measured with a Tono-pen tonometer pre-operation and 3, 7, 14, 21 and 28d post-operation. Ultrasound biomicroscopy was performed to visualize the Schlemm canal microcatheter in the Schlemm canal and the sclera pool. RESULTS: The Schlemm canal microcatheter could be used to perform circumferential canaloplasty in the rabbit glaucoma animal model. IOP was lower in the treatment group than that in the model group 3, 7, 14 and 28d after operation. There were no significant differences in IOP between the control group and treatment group. The differences among the three groups were statistically significant (3d: F=41.985, P<0.001; 7d: F=65.696, P<0.001; 14d: F=114.599, P<0.001; 28d: F=55.006, P<0.001. CONCLUSION: Circumferential canaloplasty is safe and effective in control of experimental glaucoma model in rabbits.

  11. Stroke from Delayed Embolization of Polymerized Glue Following Percutaneous Direct Injection of a Carotid Body Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Krishnamoorthy, Thamburaj; Gupta, Arun Kumar; Rajan, Jayadevan E; Thomas, Bejoy [Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, (India)

    2007-06-15

    Direct percutaneous embolization of hypervascular tumors results in more effective preoperative devascularization. Migration of glue is a well known complication of direct glue injection and it may lead to stroke or cranial nerve deficits. We report here on a case of carotid body tumor in a 52-year-old man; the tumor was mainly embolized by percutaneous injection of 50% glue and this was supported with balloon protection of the internal carotid artery. Thirteen hours later, he developed hemiparesis from delayed migration of glue. The possible mechanisms of this migration are discussed and preventive measures are suggested. Preoperative embolization of hypervascular tumors of the head and neck, including carotid body tumor, is often performed to decrease the amount of blood loss during surgery. Devascularization is mainly performed with particulate agents and by employing the transarterial route. More effective embolization may be achieved by performing percutaneous direct embolization of hypervascular tumors with liquid embolic agents. Even though there are few reports available on direct embolization, complications from glue migration have been reported, and this mainly happens during the procedure when the glue is in a liquid state. We report here on a case of delayed migration of polymerized glue (n-butyl-2-cyanoacrylate [NBCA]), many hours after the procedure, into the intracranial circulation and the final result was stroke. A 52-year-old male with right carotid body tumor underwent direct percutaneous glue (n-butylcyanoacrylate [NBCA]) embolization. Several hours later, he developed left hemiparesis from embolization of the polymerized glue cast. Migration of glue during percutaneous tumor embolization is presumed to occur only in the liquid state, which may lead to stroke or cranial nerve deficits. To the best of our knowledge, this is the first report of delayed glue embolization from a treated hypervascular tumor of the head and neck.

  12. Onyx embolization with the Apollo detachable tip microcatheter: A single-center experience.

    Science.gov (United States)

    Miller, Timothy R; Giacon, Luciano; Kole, Matthew J; Chen, Rong; Jindal, Gaurav; Gandhi, Dheeraj

    2018-06-01

    Purpose The Apollo Onyx Delivery Microcatheter (Ev3, Irvine, CA) is a detachable-tip microcatheter that was developed to reduce the risk of microcatheter entrapment during ethylene-vinyl alcohol copolymer (Onyx) embolizations. We report our experience with the microcatheter in a variety of neurointerventional procedures. Methods We retrospectively reviewed all Onyx embolizations performed in the head, neck, and spine using the Apollo Onyx Delivery Microcatheter from its introduction at our institution in July 2014 to August 2016. Information regarding patient diagnoses, procedural details, as well as clinical outcomes were obtained from the electronic medical record, procedure reports, and relevant angiographic imaging. Results A total of 58 arterial pedicle Onyx embolizations were performed in 37 patients. There were no cases of microcatheter entrapment, early/inadvertent tip detachment, or vessel injury upon removal of the device. There were two instances (3.5%) of leakage of Onyx from the microcatheter detachment site during embolization, which did not result in adverse sequelae. Clinical outcomes were excellent, with nearly all embolizations achieving the intended goal. In multivariate analysis, length of Onyx reflux along the microcatheter tip and utilization of a higher viscosity agent, Onyx 34, were significantly associated with tip detachment. Conclusion The use of the Apollo Microcatheter is both safe and effective during neurointerventional embolizations using Onyx. Leakage of liquid embolic agent from the detachment site is an infrequent technical complication that may be encountered with the device.

  13. Improved distal distribution of n-butyl cyanoacrylate glue by simultaneous injection of dextrose 5% through the guiding catheter: technical note

    International Nuclear Information System (INIS)

    Moore, Carolyn; Murphy, Kieran; Gailloud, Philippe

    2006-01-01

    The use of n-butyl cyanoacrylate (NBCA) as an adhesive agent for embolization of high-flow intracranial and extracranial vascular lesions is well established. To be successful, the embolization of arteriovenous malformations and fistulas must achieve obliteration of the arteriovenous shunts themselves rather than simply occlude the feeders proximal to the lesion. However, the feeders cannot always be negotiated over their entire length. This is often the case with dural arteriovenous fistulas (DAVF), which are usually vascularized by long and intricate meningeal networks. In such situations, NBCA may not be able to reach the lesion itself, rendering the embolization ineffective. We present a new technique that improves distal distribution of NBCA glue. The technique described in this report consists of injecting dextrose 5% through the guiding catheter simultaneously with the superselective injection of NBCA glue into the targeted feeding branch. The technique is illustrated with three cases of posterior fossa DAVF. In the reported cases, flooding the territory of the targeted vessel with non-ionic dextrose 5% allowed deep progression of the glue by delaying contact with ionic substances. Excellent distribution of the NBCA glue reaching the site of the arteriovenous shunts was thus obtained despite suboptimal proximal microcatheter tip positions. (orig.)

  14. Monorail snare technique for the retrieval of an adherent microcatheter from an onyx cast: technical case report.

    Science.gov (United States)

    Kelly, Michael E; Turner, Raymond; Gonugunta, Vivek; Rasmussen, Peter A; Woo, Henry H; Fiorella, David

    2008-07-01

    Microcatheters retained after Onyx (eV3 Neurovascular, Inc., Irvine, CA) embolization represent a potential source of thromboembolic complications. Catheter retention depends on the degree of Onyx reflux and vessel tortuosity. To overcome this problem, we have adapted a previously described monorail snare technique for stretched coils to remove an adherent microcatheter from the occipital artery during Onyx embolization of a dural arteriovenous fistula. We used this technique successfully in a 62-year-old man with a posterior fossa dural arteriovenous fistula. An Echelon-10 microcatheter (eV3 Neurovascular, Inc.) system became adherent in the right occipital artery because of reflux and vessel tortuosity. Significant stretching of the microcatheter was observed during attempted removal. A 2-mm Amplatz Goose Neck microsnare (Microvena Corp., White Bear Lake, MN) was placed through a Rapid Transit microcatheter (Cordis Corp., Miami, FL). The hub of the indwelling Echelon microcatheter was cut off and the snare advanced over the outside of the microcatheter. The snare and Rapid Transit microcatheter were then advanced into the guiding catheter (6-French) as a unit over the indwelling Echelon microcatheter. Using the adherent Echelon as a "monorail" guide, the snare and Rapid Transit microcatheter were advanced distally into the occipital artery and the snare was retracted to engage the microcatheter. The microcatheters and snare were then easily removed because of the second vector of force placed by the snare system on the adherent microcatheter very close to the point of adherence. The monorail snare technique represents a simple and safe way to remove an adherent microcatheter from an Onyx cast during the embolization of dural arteriovenous fistulas. Prospective knowledge of this technique will facilitate more aggressive embolization without the reservation that a retained microcatheter could require surgical removal or anticoagulation.

  15. Transarterial (chemo)embolisation for unresectable hepatocellular carcinoma

    DEFF Research Database (Denmark)

    Oliveri, Roberto S; Wetterslev, Jørn; Gluud, Christian

    2011-01-01

    Hepatocellular carcinoma (HCC) results in more than 600,000 deaths per year. Transarterial embolisation (TAE) and transarterial chemoembolisation (TACE) have become standard loco-regional treatments for unresectable HCC.......Hepatocellular carcinoma (HCC) results in more than 600,000 deaths per year. Transarterial embolisation (TAE) and transarterial chemoembolisation (TACE) have become standard loco-regional treatments for unresectable HCC....

  16. Retrieving microcatheters from Onyx casts in a series of brain arteriovenous malformations: a technical report.

    Science.gov (United States)

    Alamri, A; Hyodo, A; Suzuki, K; Tanaka, Y; Uchida, T; Takano, I; Kowata, K; Iwatate, K; Suzuki, R

    2012-11-01

    To date, the "monorail snare technique" for the retrieval of entombed microcatheter tips during Onyx(TM) (ev3, Irvine, CA) embolisation of brain arteriovenous malformations (BAVM) has not been described. We report our experiences and some technical aspects in using this technique for the retrieval of entombed Marathon(TM) microcatheter (ev3, Plymouth, MN) tips during Onyx embolisation of BAVM treatment. Onyx was used in the embolisation of 11 patients using 25 feeders over 14 sessions. The 'monorail snare technique' was employed for 14 feeders. Each time, an Amplatz 4 mm Gooseneck Microsnare(TM) (ev3, Plymouth, MN) was loaded into an Excelsior 1018(TM) microcatheter (Boston Scientific, Natick, MA). The Marathon microcatheter was cut just distal to the hub, and the Amplatz/Excelsior combination was introduced along the length of the Marathon microcatheter towards its distal end, as far as possible. The embedded catheter was ensnared and both catheters were pulled free. Microcatheter tip removal was successful in all cases, except for one microcatheter tip becoming detached and needing no further intervention. There were no complications as a direct result of the snare technique. The monorail snare technique is a safe and easy technique for retrieving Onyx-encased microcatheter tips in the treatment of BAVM.

  17. Use of triple microcatheters for endovascular treatment of wide-necked intracranial aneurysms: A single center experience

    International Nuclear Information System (INIS)

    Cho, Young Dae; Rhim, Jong Kook; Kang, Hyun Seung; Kim, Jeong Eun; Cho, Won Sang; Han, Moon Hee; Park, Jeong Jin; Jeon, Jin Pyeong

    2015-01-01

    The dual microcatheter technique is common practice for coil embolization of a wide-necked aneurysm, due to safety and efficacy. However, technical limitations of some complex configurations may necessitate additional microcatheters to bolster coil stability, compact the coil, or for protection. Described herein is a triple microcatheter technique for endovascular management of wide-necked intracranial aneurysms. Data accruing prospectively between January 2006 and October 2014 on simultaneously executed triple microcatheter coil embolization procedures done in 38 saccular aneurysms were reviewed. Clinical and morphological outcomes were assessed, with emphasis on technical aspects of treatment. The triple microcatheter technique was successfully applied to all 38 saccular aneurysms, involving the posterior communicating artery (n = 13), the middle cerebral artery (n = 10), the basilar tip (n = 7), the anterior cerebral artery (n = 5), and the internal carotid artery (n = 3). Stent protection was added in four patients and balloon remodeling in one. Dual microcatheters (n = 24) were usually deployed to deliver the coil within sacs of aneurysms, with the additional microcatheter used for protection. Otherwise, triple microcatheters were deployed for coil delivery (n = 11) or coils were delivered via a single microcatheter, with dual microcatheters deployed for protection (n = 3). Successful occlusion of aneurysms was achieved in 89.5% of cases, with no procedure-related morbidity or mortality. Stable occlusion was maintained in 72.2% (26/36) of the aneurysms at the final follow-up (mean interval, 30.2 ± 22.7 months). The outcomes of this limited study suggest that the triple microcatheter technique may be an effective and safe therapeutic option for wide-necked aneurysms, using technical strategies tailored to complex angio-anatomic configurations

  18. The Steerable Microcatheter: A New Device for Selective Catheterisation

    International Nuclear Information System (INIS)

    Soyama, Takeshi; Yoshida, Daisuke; Sakuhara, Yusuke; Morita, Ryo; Abo, Daisuke; Kudo, Kohsuke

    2017-01-01

    The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.

  19. The Steerable Microcatheter: A New Device for Selective Catheterisation

    Energy Technology Data Exchange (ETDEWEB)

    Soyama, Takeshi [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology (Japan); Yoshida, Daisuke [Sapporo Yamanoue Hospital, Department of Radiology (Japan); Sakuhara, Yusuke, E-mail: yusaku@med.hokudai.ac.jp; Morita, Ryo; Abo, Daisuke; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-06-15

    The steerable microcatheter (SwiftNINJA, Sumitomo Bakelite, Tokyo, Japan), which has a remote-controlled flexible tip manipulated using a dial in the handgrip, was recently developed and delivered to the market. This device enables the user to change the angle of the microcatheter tip manually, and potentially makes selective catheterisation easier. We evaluated its unique characteristics and utility in selective catheterisation and coil embolization. This article describes: (1) the advantages of this device in catheterisations involving acute angle branches, and (2) a new technique of compact coil packing with the use of intentional folding by the bendable tip of the catheter.

  20. Microcatheter Embolization of Intractable Idiopathic Epistaxis

    International Nuclear Information System (INIS)

    Leppaenen, Martti; Seppaenen, Seppo; Laranne, Jussi; Kuoppala, Katriina

    1999-01-01

    Purpose: To assess the efficacy and safety of microcatheter embolization in the treatment of intractable idiopathic epistaxis. Methods: Thirty-seven patients underwent microcatheter embolization in 1991-1998. We evaluated retrospectively the technical and clinical outcome, the number of complications, the duration of embolization in each case, and the number of blood transfusions needed. All embolizations were done with biplane digital subtraction angiography (DSA) equipment. The procedure was carried out under local anesthesia using transfemoral catheterization, except in one case where the translumbar route was used. Tracker 18 or 10 microcatheters were advanced as far as possible to the distal branches of the sphenopalatine artery. Polyvinyl alcohol (PVA) particles were used for embolization in most cases, while platinum coils or a combination of these two materials were occasionally used. The primary outcome was always assessed immediately by angiography. Follow-up data were obtained from patient records, by interviewing patients on the telephone or by postal questionnaires when necessary. The mean follow-up time was 21 months. Results: The embolization was technically successful in all 37 cases. A curative outcome was achieved in 33 cases (89%). The mean duration of the procedure was 110 min. Four patients (8%) had mild transient complications, but no severe or persistent complications were encountered. Twenty-three patients needed a blood transfusion. Slight rebleeding occurred in three patients during the follow-up; all responded to conservative treatment. One patient suffered two episodes of rebleeding within 2 months after primary embolization. Re-embolizations successfully stopped the bleeding. Conclusion: Embolization is the primary invasive modality for treating intractable idiopathic epistaxis. It proved both safe and effective over a relatively long follow-up

  1. Hydrophilic polymer-coated microcatheter-guide wire system for superselective angiographic procedures

    International Nuclear Information System (INIS)

    Kobayashi, Hisashi; Hiraki, Yoshiyuki; Nishimoto, Hidetou; Miyazono, Nobuaki; Satake, Mitsuo; Shinohara, Shinji

    1988-01-01

    A hydrophilic polymer-coated microcatheter-guide wire device has been newly developed for superselective angiography and interventional procedures. The injection rate of this microcatheter was estimated at 2.0 ml/sec. on the maximum pressure of 300 psi when used a non-ionic low osmolar contrast medium, Iopamidol 300. In two of three cases this catheter could make easy insertion into the peripheral branches of the right hepatic artery which were approximately 1 mm in vascular diameter. (author)

  2. Serum aluminium levels in glue-sniffer adolescent and in glue containers.

    Science.gov (United States)

    Akay, Cemal; Kalman, Süleyman; Dündaröz, Ruşen; Sayal, Ahmet; Aydin, Ahmet; Ozkan, Yalçin; Gül, Hüsamettin

    2008-05-01

    Glue sniffing is a serious medical problem among teenagers. Various chemical substances such as toluene and benzene containing glues have been reported to be toxic. It has been demonstrated that some toxic metals such as lead are elevated in the blood of solvent-addicted patients. Whereas aluminium is an element that has toxic effects on neurological, hematopoetic system and bone metabolism. We want to determine the serum levels of aluminium in glue-sniffer adolescents in comparison with healthy subjects. In addition, we compared aluminium levels of different commercial glue preparations (i.e. metal and plastic containers), to determine which type of container is better for less aluminium toxicity. We measured serum levels of aluminium in 37 glue-sniffer and 37 healthy subjects using atomic absorption spectrophotometry. The average duration of glue-sniffer was 3.8 +/- 0.8 years. We also measured aluminium levels of 10 commercial glue preparations that seven of them with metal and three with plastic containers. We found that serum levels of aluminium were 63.29 +/- 13.20 ng/ml and 36.7 +/- 8.60 ng/ml in glue-sniffer and in control subjects, respectively (P sniffers, it may be a good step to market of glue preparations in plastic instead of metal containers.

  3. Rapid exchange ultra-thin microcatheter using fibre-optic sensing technology for measurement of intracoronary fractional flow reserve.

    Science.gov (United States)

    Diletti, Roberto; Van Mieghem, Nicolas M; Valgimigli, Marco; Karanasos, Antonis; Everaert, Bert R C; Daemen, Joost; van Geuns, Robert-Jan; de Jaegere, Peter P; Zijlstra, Felix; Regar, Evelyn

    2015-08-01

    The present report describes a novel coronary fractional flow reserve (FFR) system which allows FFR assessment using a rapid exchange microcatheter (RXi). The RXi microcatheter is compatible with standard 0.014" coronary guidewires facilitating lesion negotiation and FFR assessment in a wide range of coronary anatomies. In case of serial lesions, a microcatheter would have the important advantage of allowing multiple pullbacks while maintaining wire access to the vessel. The RXi is a fibre-optic sensor technology-based device. This technology might allow reduction in signal drift. The RXi microcatheter's fibre-optic sensor is located 5 mm from the distal tip. The microcatheter profile at the sensor site is 0.027"0.036". The segment of the catheter which is intended to reside within the target lesion is proximal to the sensor and has dimensions decreased to 0.020"0.025"; these dimensions are comparable to a 0.022" circular-shaped wire. The RXi microcatheter FFR system represents a novel technology that could allow easier lesion negotiation, maintaining guidewire position, facilitating pullbacks for assessment of serial lesions and simplifying the obtainment of post-intervention FFR measurements. The optical sensing technology could additionally result in less signal drift. Further investigations are required to evaluate the clinical value of this technology fully.

  4. Factors Predicting Survival after Transarterial Chemoembolization of Unresectable Hepatocellular Carcinoma

    Directory of Open Access Journals (Sweden)

    Farina M. Hanif

    2014-10-01

    Full Text Available Background: Transarterial chemoembolization is the preferred treatment for unresectable, intermediate-stage hepatocellular carcinoma. Survival after transarterial chemoembolization can be highly variable. The purpose of this study is to identify the factors that predict overall survival of patients with unresectable hepatocellular carcinoma who undergo transarterial chemoembolization as the initial therapy. Methods:We included patients who underwent transarterial chemoembolization from 2007 to 2012 in this study. Patient’s age, gender, cause of cirrhosis, Child-Turcotte-Pugh score, model of end-stage liver disease score, Cancer of the Liver Italian Program score, Okuda stage, alpha- fetoprotein level, site, size and number of tumors were recorded. Radiological response to transarterial chemoembolization was assessed by computerized tomography scan at 1 and 3 months after the procedure. Repeat sessions of transarterial chemoembolization were performed according to the response. We performed survival assessment and all patients were assessed for survival at the last follow-up. Results: Included in this study were 71 patients of whom there were 57 (80.3 % males, with a mean age of 51.9±12.1 years (range: 18-76 years. The mean follow-up period was 12.5±10.7 months. A total of 31 (43.7% patients had only one session of transarterial chemoembolization, 17 (23.9% underwent 2 and 11 (15.5% had 3 or more sessions. On univariate analysis, significant factors that predicted survival included serum bilirubin (P=0.02, esophageal varices (P=0.002, Cancer of the Liver Italian Program score (P=0.003, tumor size (P=0.005, >3 sessions of transarterial chemoembolization (P=0.006 and patient's age (P=0.001. Cox regression analysis showed that tumor size of 1 transarterial chemoembolization session (P=0.004 were associated with better survival. Conclusion: Our study demonstrates that survival after transarterial chemoem- bolization is predicted by tumor size

  5. Microcatheter with a ball tip for hepatic embolization and intra-arterial chemotherapy

    International Nuclear Information System (INIS)

    Hori, S.; Matsushita, M.; Narumi, Y.; Fujita, M.; Tomoda, K.; Marukawa, T.; Kuroda, C.; Kozuka, T.

    1989-01-01

    A microcatheter used mainly for cranial arterial embolization and chemotherapy was employed for hepatic arterial embolization. The tip of the microcatheter is inflated like a small balloon which then acts as a calibrated-leak balloon. A coaxial system employing a conventional catheter for abdominal angiography combined with a propulsion chamber was used. Successful chemotherapy and embolization by Lipiodol and Spongel was carried out even in cases in whom it had been considered impossible to insert a catheter into the desired arteries. (orig.)

  6. BEWARE OF...SUPER GLUES!!

    CERN Multimedia

    2006-01-01

    What happened? A number of accidents have occurred with the use of 'Super Glues'. Some individuals have suffered injuries - severe irritation, or skin bonded together - through getting glue on their face and in their eyes. What are the hazards associated with glues? 'Super Glues' (i.e. cyanoacrylates): Are harmful if swallowed and are chemical irritants to the eyes, respiratory system and skin. Present the risk of polymerization (hardening) leading to skin damage. Be careful ! 'Super Glues' can bond to skin and eyes in seconds. Note: Other glues, resins and hardeners are also chemicals and as such can cause serious damage to the skin, eyes, respiratory or digestive tract. (For example: some components can be toxic, harmful, corrosive, sensitizing agents, etc.). How to prevent accidents in the future? Read the Material Safety Data Sheet (MSDS) for all of the glues you work with. Check the label on the container to find out which of the materials you work with are hazardous. Wear the right Per...

  7. Bistable microvalve and microcatheter system

    Science.gov (United States)

    Seward, Kirk Patrick

    2003-05-20

    A bistable microvalve of shape memory material is operatively connected to a microcatheter. The bistable microvalve includes a tip that can be closed off until it is in the desired position. Once it is in position it can opened and closed. The system uses heat and pressure to open and close the microvalve. The shape memory material will change stiffness and shape when heated above a transition temperature. The shape memory material is adapted to move from a first shape to a second shape, either open or closed, where it can perform a desired function.

  8. Microcatheter Shaping for Intracranial Aneurysm Coiling Using the 3-Dimensional Printing Rapid Prototyping Technology: Preliminary Result in the First 10 Consecutive Cases.

    Science.gov (United States)

    Namba, Katsunari; Higaki, Ayuho; Kaneko, Naoki; Mashiko, Toshihiro; Nemoto, Shigeru; Watanabe, Eiju

    2015-07-01

    An optimal microcatheter is necessary for successful coiling of an intracranial aneurysm. The optimal shape may be predetermined before the endovascular surgery via the use of a 3-dimensional (3D) printing rapid prototyping technology. We report a preliminary series of intracranial aneurysms treated with a microcatheter shape determined by the patient's anatomy and configuration of the aneurysm, which was fabricated with a 3D printer aneurysm model. A solid aneurysm model was fabricated with a 3D printer based on the data acquired from the 3D rotational angiogram. A hollow aneurysm model with an identical vessel and aneurysm lumen to the actual anatomy was constructed with use of the solid model as a mold. With use of the solid model, a microcatheter shaping mandrel was formed to identically line the 3D curvature of the parent vessel and the long axis of the aneurysm. With use of the mandrel, a test microcatheter was shaped and validated for the accuracy with the hollow model. All the planning processes were undertaken at least 1 day before treatment. The preshaped mandrel was then applied in the endovascular procedure. Ten consecutive intracranial aneurysms were coiled with the pre-planned shape of the microcatheter and evaluated for the clinical and anatomical outcomes and microcatheter accuracy and stability. All of pre-planned microcatheters matched the vessel and aneurysm anatomy. Seven required no microguidewire assistance in catheterizing the aneurysm whereas 3 required guiding of a microguidewire. All of the microcatheters accurately aligned the long axis of the aneurysm. The pre-planned microcatheter shapes demonstrated stability in all except in 1 large aneurysm case. When a 3D printing rapid type prototyping technology is used, a patient-specific and optimal microcatheter shape may be determined preoperatively. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. An Unusual Complication Following Transarterial Chemoembolization: Acute Myocardial Infarction

    International Nuclear Information System (INIS)

    Lai Yiliang; Chang Weichou; Kuo Wuhsien; Huang Tienyu; Chu Hengcheng; Hsieh Tsaiyuan; Chang Weikuo

    2010-01-01

    Transarterial chemoembolization has been widely used to treat unresectable hepatocellular carcinoma. Various complications have been reported, but they have not included acute myocardial infarction. Acute myocardial infarction results mainly from coronary artery occlusion by plaques that are vulnerable to rupture or from coronary spasm, embolization, or dissection of the coronary artery. It is associated with significant morbidity and mortality. We present a case report that describes a patient with hepatocellular carcinoma who underwent transarterial chemoembolization and died subsequently of acute myocardial infarction. To our knowledge, there has been no previous report of this complication induced by transarterial chemoembolization for hepatocellular carcinoma. This case illustrates the need to be aware of acute myocardial infarction when transarterial chemoembolization is planned for the treatment of hepatocellular carcinoma, especially in patients with underlying coronary artery disease.

  10. Feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke

    International Nuclear Information System (INIS)

    Wang Wei; Li Cheng; Liu Zhensheng; Zhang Xinjiang; Zhou Longjiang; Yin Haiyan

    2010-01-01

    Objective: To assess the feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke. Methods: Six patients with acute cerebral infarction within 6 hours underwent intraarterial thrombolysis, in which arterial blood bypass was used. A 2.3 F microcatheter was advanced through the clot and two milliliters of contrast was injected beyond the clot that remained stagnant in the major branches. At this point, 20 ml of oxygenated blood from femoral artery was injected for 2 minutes through the microcatheter past the occluding clot. Then, conventional intraarterial thrombolysis, including fibrinolytic agents infusion and mechanical disruption, was performed. Intraarterial thrombolysis and oxygenated blood infusion alternated every 30 minutes. Results: Every patient received arterial blood bypass with average three times (from 1 to 5 times) in the process of the intraarterial thrombolysis, which cost (8.0 ± 3.2) min. Recanalization was achieved in all 6 patients, but minor subarachnoid hemorrhage developed in one patient. All the patients got favorable clinical outcome. The life conditions is excellent in 4 cases and good in 2 cases. Conclusions: Arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke might be feasible, which did not interfere with conventional intraarterial thrombolysis and prolong the operation time significantly but could protect ischemic penumbra. (authors)

  11. Double microcatheter technique for coiling intracranial aneurysms with unfavorable configurations

    Directory of Open Access Journals (Sweden)

    WANG Shu-yuan

    2013-03-01

    Full Text Available Background Although stent-assisted technique has been widely used clinically, it is still hard to perform coiling treatment for complicated intracranial aneurysms, including relatively wide-necked tiny aneurysms and lobulated wide-necked aneurys ms with important branch vessels arising from the neck. This study aims to investigate the feasibility and clinical results of endovascular treatment for intracranial aneurysms with unfavorable configurations by using double microcatheter technique. Methods Thirty-three cases with complicated aneurysms were treated by using double microcatheter technique from April 2008 to November 2012. The locations of these aneurysms were anterior communicating artery (7 cases, posterior communicating artery (14 cases, ophthalmic artery (3 cases, anterior choroidal artery (3 cases, origin of posterior inferior cerebellar artery (3 cases, bifurcation of middle cerebral artery (2 cases and top of basilar artery (1 case. The mean neck- to-body (width ratio was 0.80 ± 0.21 (0.53-1.33. The mean body (width-to-dome (height ratio was 1.12 ± 0.37 (0.55-2.12. The mean dome (height-to-neck ratio was 1.26 ± 0.41 (0.65-2.96. The diameter of neck ≥4 mm was seen in 7 aneurysms, neck≥height in 9 and neck ≥width in 8. Besides, there were 9 very small aneurysms (the maximum diameter≤3 mm and 13 aneurysms with important branch vessels arising from the neck. All of these aneurysms were treated with coiling by using double microcatheter technique. Results All aneurysms were successfully embolized. Immediate postembolization angiography showed no residual contrast filling in 19 aneurysms, and residual filling in 14. There were some small loops protruding from the neck without influencing the blood flow in 12 cases. At discharge, according to modified Rankin Scale (mRS, 30 patients with 0-1 scores presented excellent clinical outcomes and 3 patients with 2 scores had cognitive dysfunction and moderate disability due to vasospasm

  12. Glue-paste linings

    DEFF Research Database (Denmark)

    Fuster-López, Laura; Andersen, Cecil Krarup; Bouillon, Nicolas

    2017-01-01

    Glue-paste linings of (Western) canvas paintings have been performed with a variety of materials throughout history and are present in a very significant amount of artworks in collections in Europe and elsewhere. Cereal flours and animal glues were usually the main ingredients because they were r...

  13. The GlueX DIRC detector

    Science.gov (United States)

    Barbosa, F.; Bessuille, J.; Chudakov, E.; Dzhygadlo, R.; Fanelli, C.; Frye, J.; Hardin, J.; Kelsey, J.; Patsyuk, M.; Schwarz, C.; Schwiening, J.; Stevens, J.; Shepherd, M.; Whitlatch, T.; Williams, M.

    2017-12-01

    The GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed in 2017. We present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.

  14. 21 CFR 178.3120 - Animal glue.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  15. Bovine glue (BioGlue) is catabolized by enzymatic reaction in the vascular dog model.

    Science.gov (United States)

    Van Belleghem, Yves; Forsyth, Ramses G; Narine, Kishan; Moerman, Annelies; Taeymans, Yves; Van Nooten, Guido J

    2004-06-01

    The aim of the study is to explore the feasibility, patency, and histologic changes of a sutureless vascular anastomotic technique using biological glue as sole fixation method. Eight mongrel dogs (+/-15 kg) underwent direct reanastomosis of their transsected iliac arteries. Both ends were placed on a 5-mm balloon and the anastomosis was secured with biological glue (BioGlue, Cryolife, Kennesaw, GA). No intravascular suture material was used. All survivors were angiographically controlled for patency after 6 weeks and 3 months. Then the animals were euthanized and tissues were obtained for histologic and pathologic examination by light and electron microscopy. All procedures were successful except for 1 animal that died of uncontrollable bleeding at the anastomotic site. All first-time angiographically controlled grafts except three were patent. One animal showed manifest signs of fungal infection. Histology detected early granulocyte infiltration with an important enzymatic reaction adjacent to the surface of glue. Later on, the glue gradually regressed to disappear completely. Fibroblastic neointimal lining was noticed in most of the anastomoses, with some marked differences in the endothelium compared with normal. Good permeability (57%) was observed in this new sutureless anastomotic technique in the canine model. In contrast to previous reported studies we noticed a clear enzymatic breakdown of the glue before total disappearance. It is not yet known to what extend use of the bovine glue was responsible for this phenomenon.

  16. Role of assesssment for retreatment with transarterial chemoembolization score in decision of retreatment with trans-arterial chemo-embolization sessions in patients with hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Abbasi, A.H.; Abid, S.; Haq, T.U.; Awan, S.

    2017-01-01

    Background: The objective behind this study was to determine that Assessment for Re-treatment with Transarterial chemoembolization (ART) score is really applicable in patients with hepatocellular carcinoma. Methods: A cross sectional observational study was conducted on all patients with hepatocellular carcinoma of intermediate stage and undergone ≥2 Transarterial chemoembolization. ART score was assessed before and after each session of Transarterial chemoembolization. Multi-logistic regression analysis was performed to compare the final outcome of patients with ART score of ≥2.5 into groups with two and more than two Trans-arterial chemo-embolization sessions. Results: A total of 100 HCC patients were recruited for final analysis. Our study participants consisted of total 100 HCC patients. Mean Child Pugh score was 6.1±0.95. In our study, most of the study participants (n=63) had ART score of less than 1.5 as compared to ART score >2.5 (n=37). A significant proportion of patients with ART score of 2.5, p-value<0.001. Patients with ART score of more than 2.5 did not show any survival benefit after having 3rd or 4th Trans-arterial chemo-embolization session, p=0.47. Conclusions: Our study findings suggest that those HCC patients who receive multiple sessions of TACE with a low ART score have more favourable outcomes with increased survival rate. (author)

  17. Refinement of a thrombectomy technique to treat acute ischemic stroke: Technical note on microcatheter advance during retrieving self expandable stent

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Catholic Univ. of Daegu School of Medicine, Daegu (Korea, Republic of)

    2012-07-15

    Temporary stenting and thrombectomy by use of the Solitaire stent (ev3, Irvine, CA, USA) has shown prompt and successful recanalization of the acutely occluded major cerebral artery. However, even if rarely reported, inadvertent stent detachment may occur as an innate drawback and full deployment of the stent was considered to increase the risk. In our patients, the Solitaire stent did not fully unfold to prevent inadvertent detachment. Before retrieval of the stent, the tip of the microcatheter was advanced forward carefully under fluoroscopic observation until it met the presumed thrombus segment and a subtle sense of resistance was felt in the fingers guiding the stent. After retrieval, complete recanalization was achieved, and the thrombus was trapped between the tip of the microcatheter and the stent strut. We present 2 cases of successful thrombi captures by advancing a microcatheter during Solitaire stent retrieval, and we suggest that advancing the microcatheter can be a useful refinement to the thrombectomy technique for acute ischemic stroke.

  18. Glue Guns: Aiming for Safety

    Science.gov (United States)

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  19. Histological effects of fibrin glue and synthetic tissue glues on the spinal cord: are they safe to use?

    Science.gov (United States)

    Kalsi, Pratipal; Thom, Maria; Choi, David

    2017-12-01

    Fibrin glues such as Tisseel ® have been established in neurosurgery for over thirty years. They are recommended for extradural use but have intradural applications. Brachial plexus reimplantation after trauma requires intradural fibrin glue because reimplanted nerves cannot be sutured to the spinal cord. Recently synthetic glues have become popular in spinal surgery but there is limited information about their safety. Our study compared the histological effects of Tisseel ® , Adherus ® and BioGlue ® on spinal cord using our rat brachial plexus repair model. Randomised observational animal study. Forty-one Sprague-Dawley rats divided in to control (n = 9), Tisseel ® (n = 8), BioGlue ® (n = 10) and Adherus ® (n = 14) groups. Under general anaesthesia a posterior midline cervical incision was made and hemi-laminectomies performed at C7 and T1. Dura was opened and T1 dorsal root transected and repositioned on the spinal cord. Two drops of Tisseel ® , BioGlue ® , Adherus ® or no glue (control) were applied over the cut nerve and cord. At days 7, 14 and 28 rats were euthanized, processed and sections stained with Haematoxylin & Eosin and evaluated blind by a neuropathologist. Control and Tisseel ® groups showed only mild focal inflammation in the cord. Adherus ® and Bioglue ® groups showed evidence of spinal cord inflammation and degeneration. All BioGlue ® and Adherus ® rats had evidence of distortion of the cord from the glue mass at all time points. Two BioGlue ® -treated and one Adherus ® -treated rat developed a hemiparesis. One BioGlue ® rat developed hind limb paralysis. One BioGlue ® rat failed to wake up at the end of the procedure. There were no complications in control and Tisseel ® groups. Tisseel ® caused a similar inflammatory response to control and may be used on spinal cord. BioGlue ® and Adherus ® should be applied thinly for a watertight dural closure but intradural use and contact with spinal tissue must be

  20. Transarterial Infusion Chemotherapy Using Cisplatin-Lipiodol Suspension With or Without Embolization for Unresectable Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Kawaoka, Tomokazu; Aikata, Hiroshi; Takaki, Shintaro; Katamura, Yoshio; Hiramatsu, Akira; Waki, Koji; Takahashi, Shoichi; Hieda, Masashi; Toyota, Naoyuki; Ito, Katsuhide; Chayama, Kazuaki

    2009-01-01

    We evaluate the long-term prognosis and prognostic factors in patients treated with transarterial infusion chemotherapy using cisplatin-lipiodol (CDDP/LPD) suspension with or without embolization for unresectable hepatocellular carcinoma (HCC). Study subjects were 107 patients with HCC treated with repeated transarterial infusion chemotherapy alone using CDDP/LPD (adjusted as CDDP 10mg/LPD 1ml). The median number of transarterial infusion procedures was two (range, one to nine), the mean dose of CDDP per transarterial infusion chemotherapy session was 30 mg (range, 5.0-67.5 mg), and the median total dose of transarterial infusion chemotherapy per patient was 60 mg (range, 10-390 mg). Survival rates were 86% at 1 year, 40% at 3 years, 20% at 5 years, and 16% at 7 years. For patients with >90% LPD accumulation after the first transarterial infusion chemotherapy, rates were 98% at 1 year, 60% at 3 years, and 22% at 5 years. Multivariate analysis identified >90% LPD accumulation after the first transarterial infusion chemotherapy (p = 0.001), absence of portal vein tumor thrombosis (PVTT; p < 0.001), and Child-Pugh class A (p = 0.012) as independent determinants of survival. Anaphylactic shock was observed in two patients, at the fifth transarterial infusion chemotherapy session in one and the ninth in the other. In conclusion, transarterial infusion chemotherapy with CDDP/LPD appears to be a useful treatment option for patients with unresectable HCC without PVTT and in Child-Pugh class A. LPD accumulation after the first transarterial infusion chemotherapy is an important prognostic factor. Careful consideration should be given to the possibility of anaphylactic shock upon repeat infusion with CDDP/LPD.

  1. Fibrin glue in ophthalmology

    Directory of Open Access Journals (Sweden)

    Panda Anita

    2009-01-01

    Full Text Available Suturing is a time consuming task in ophthalmology and suture induced irritation and redness are frequent problems. Postoperative wound infection and corneal graft rejection are examples of possible suture related complications. To prevent these complications, ophthalmic surgeons are switching to sutureless surgery. A number of recent developments have established tissue adhesives like cyanoacrylate glue and fibrin glue as attractive alternatives to sutures. A possible and promising new application for tissue adhesives is to provide a platform for tissue engineering. Currently, tissue glue is being used for conjunctival closure following pterygium and strabismus surgery, forniceal reconstruction surgery, amniotic membrane transplantation, lamellar corneal grafting, closure of corneal perforations and descematoceles, management of conjunctival wound leaks after trabeculectomy, lid surgery, adnexal surgery and as a hemostat to minimise bleeding. The purpose of this review is to discuss the currently available information on fibrin glue.

  2. Bistable Microvalve For Use With Microcatheter System

    Science.gov (United States)

    Seward, Kirk Patrick

    2003-12-16

    A bistable microvalve of shape memory material is operatively connected to a microcatheter. The bistable microvalve includes a tip that can be closed off until it is in the desired position. Once it is in position it can be opened and closed. The system uses heat and pressure to open and close the microvalve. The shape memory material will change stiffness and shape when heated above a transition temperature. The shape memory material is adapted to move from a first shape to a second shape, either open or closed, where it can perform a desired function.

  3. The application of microcatheter superselective catheterization in interventional chemoembolization for multiple hepatocarcinomas: an initial experience in 34 cases

    International Nuclear Information System (INIS)

    Xu Xiaolu; Chen Yongqiang; Wang Qing

    2012-01-01

    Objective: To assess the clinical value of superselective catheterization by using microcatheter in interventional chemoembolization for multiple hepatocarcinomas. Methods: A total of 68 patients with multiple hepatocarcinomas were enrolled in this study. The clinical data were retrospectively analyzed. Superselective catheterization by using a microcatheter was carried out in 34 cases (study group) and superselective catheterization by using a 4-5 F common catheter was performed in 34 cases (control group). The hepatic dysfunctions and the survival rate at 0.5, 1, 2 years were compared between the two groups. Results: The liver function of the patients in study group was much better than that of the patients in control group (P<0.05), and the survival time of the patients in study group was much longer than that of the patients in control group (P<0.05). Conclusion: For the treatment of multiple hepatocarcinomas, interventional chemoembolization by using microcatheter superselective catheterization technique is technically simple and clinically effective with high success rate and fewer complications. (authors)

  4. Contact dermatitis to ethyl-cyanoacrylate-containing glue.

    Science.gov (United States)

    Belsito, D V

    1987-10-01

    3 patients with contact dermatitis to an ethyl cyanoacrylate glue are presented. Although reactions to cyanoacrylate glues are considered rare, more widespread use of these products by nail salons is likely to be associated with an increased incidence of positive reactions. All 3 of our patients came into contact with the glue during "nail wrapping". In this process, ethyl cyanoacrylate or another "instant glue" is used to adhere glue-impregnated silk or linen to the nail plate which is then filed to shape the nail. This procedure creates fine acrylic-containing dust which may facilitate an allergic response. Fine particulate matter may be transferred to other distant cutaneous sites, such as the eyelids, resulting in more widespread cutaneous eruptions. Dermatologists in areas where nail wrapping is becoming more fashionable are advised to be alert to potential cyanoacrylate glue allergies which present as periungual eczema which may be associated with eyelid dermatitis and features of nummular dermatitis particularly over the dorsal hand.

  5. Endovascular brain intervention and mapping in a dog experimental model using magnetically-guided micro-catheter technology.

    Science.gov (United States)

    Kara, Tomas; Leinveber, Pavel; Vlasin, Michal; Jurak, Pavel; Novak, Miroslav; Novak, Zdenek; Chrastina, Jan; Czechowicz, Krzysztof; Belehrad, Milos; Asirvatham, Samuel J

    2014-06-01

    Despite the substantial progress that has been achieved in interventional cardiology and cardiac electrophysiology, endovascular intervention for the diagnosis and treatment of central nervous system (CNS) disorders such as stroke, epilepsy and CNS malignancy is still limited, particularly due to highly tortuous nature of the cerebral arterial and venous system. Existing interventional devices and techniques enable only limited and complicated access especially into intra-cerebral vessels. The aim of this study was to develop a micro-catheter magnetically-guided technology specifically designed for endovascular intervention and mapping in deep CNS vascular structures. Mapping of electrical brain activity was performed via the venous system on an animal dog model with the support of the NIOBE II system. A novel micro-catheter specially designed for endovascular interventions in the CNS, with the support of the NIOBE II technology, was able to reach safely deep intra-cerebral venous structures and map the electrical activity there. Such structures are not currently accessible using standard catheters. This is the first study demonstrating successful use of a new micro-catheter in combination with NIOBE II technology for endovascular intervention in the brain.

  6. Glue Sniffers with Special Needs.

    Science.gov (United States)

    O'Connor, Denis

    1987-01-01

    Glue sniffing and solvent misuse have seriously affected children and teenagers throughout the United Kingdom. This article discusses glue sniffing in terms of prevalence, association with disability, physical and psychological effects, signs and symptoms, counseling for sniffers, and successful interventions including an approach using videotape…

  7. Superselective transarterial embolization for the management of acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Lee, In Kyoung; Kim, Young Min; Kim, Jeong; Shin, Sang Soo; Yoon Woong; Kim, Jae Kyu; Park, Jin Gyoon; Cho, Chol Kyoon; Kang, Heoung Keun

    2006-01-01

    We wanted to evaluate the safety and effectiveness of superselective transarterial embolization for the management of gastrointestinal bleeding. We evaluated 97 of 115 patients who had undergone diagnostic angiography and transarterial embolization for gastrointestinal bleeding from February 2001 to July 2004, and they subsequently underwent superselective transarterial embolization. Their ages ranged from 17 to 88 years (mean age: 58.5 years), and 73 were men and 24 were women. The etiologies were a postoperative condition (n=31), ulcer (n=23), Mallory-Weiss syndrome (n=3), trauma (n=3), pseudoaneurysm from pancreatitis (n=3), diverticula (n=2), inflammatory bowel disease (n=2), tumor (n=2), Behcet's disease (n=2), hemobilia (n=1), and unknown origin (n=25). The regions of bleeding were the esophagus (n=3), stomach and duodenum (n=41), small bowel (n=38) and colon (n=15). All the patients underwent superselective transarterial embolization using microcoils, gelfoam or a combination of microcoils and gelfoam. Technical success was defined as devascularization of targeted vascular lesion or the disappearance of extravasation of the contrast media, as noted on the angiography after embolization. Clinical success was defined as the disappearance of clinical symptoms and the reestablishment of normal cardiovascular hemodynamics after transarterial embolization without any operation or endoscopic management. The technical success rate was 100%. The primary clinical success rate was 67% (65 of 97 patients). Of the 32 primary failures, fourteen patients underwent repeat embolization; of these, clinical success was achieved in all the patients and so the secondary clinical success rate was 81% (79 of 97 patients). Of the 18 patients with primary failures, five patients underwent operation, one patient underwent endoscopic management and the others died during the observation period due to disseminated coagulopathy or complications of their underlying diseases. During the

  8. Superselective transarterial embolization for the management of acute gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Kyoung; Kim, Young Min; Kim, Jeong; Shin, Sang Soo; Yoon Woong; Kim, Jae Kyu; Park, Jin Gyoon [Chonnam National University Hospital, Gwangju (Korea, Republic of); Cho, Chol Kyoon; Kang, Heoung Keun [Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of)

    2006-03-15

    We wanted to evaluate the safety and effectiveness of superselective transarterial embolization for the management of gastrointestinal bleeding. We evaluated 97 of 115 patients who had undergone diagnostic angiography and transarterial embolization for gastrointestinal bleeding from February 2001 to July 2004, and they subsequently underwent superselective transarterial embolization. Their ages ranged from 17 to 88 years (mean age: 58.5 years), and 73 were men and 24 were women. The etiologies were a postoperative condition (n=31), ulcer (n=23), Mallory-Weiss syndrome (n=3), trauma (n=3), pseudoaneurysm from pancreatitis (n=3), diverticula (n=2), inflammatory bowel disease (n=2), tumor (n=2), Behcet's disease (n=2), hemobilia (n=1), and unknown origin (n=25). The regions of bleeding were the esophagus (n=3), stomach and duodenum (n=41), small bowel (n=38) and colon (n=15). All the patients underwent superselective transarterial embolization using microcoils, gelfoam or a combination of microcoils and gelfoam. Technical success was defined as devascularization of targeted vascular lesion or the disappearance of extravasation of the contrast media, as noted on the angiography after embolization. Clinical success was defined as the disappearance of clinical symptoms and the reestablishment of normal cardiovascular hemodynamics after transarterial embolization without any operation or endoscopic management. The technical success rate was 100%. The primary clinical success rate was 67% (65 of 97 patients). Of the 32 primary failures, fourteen patients underwent repeat embolization; of these, clinical success was achieved in all the patients and so the secondary clinical success rate was 81% (79 of 97 patients). Of the 18 patients with primary failures, five patients underwent operation, one patient underwent endoscopic management and the others died during the observation period due to disseminated coagulopathy or complications of their underlying diseases. During

  9. Rejoining of cut wounds by engineered gelatin-keratin glue.

    Science.gov (United States)

    Thirupathi Kumara Raja, S; Thiruselvi, T; Sailakshmi, G; Ganesh, S; Gnanamani, A

    2013-08-01

    Rejoining of cut tissue ends of a critical site challenges clinicians. The toxicity, antigenicity, low adhesive strength, flexibility, swelling and cost of the currently employed glue demands an alternative. Engineered gelatin-keratin glue (EGK-glue) described in the present study was found to be suitable for wet tissue approximation. EGK-glue was prepared by engineering gelatin with caffeic acid using EDC and conjugating with keratin by periodate oxidation. UV-visible, (1)H NMR and circular dichroism analyses followed by experiments on gelation time, rheology, gel adhesive strength (in vitro), wet tissue approximation (in vivo), H&E staining of tissue sections at scheduled time intervals and tensile strength of the healed skin were carried out to assess the effectiveness of the EGK-glue in comparison with fibrin glue and cyanoacrylate. Results of UV-visible, NMR and CD analyses confirmed the functionalization and secondary structural changes. Increasing concentration of keratin reduces the gelation time (glue for clinical applications. Tissue approximation property assessed using the incision wound model (Wistar strain) in comparison with cyanoacrylate and fibrin glue suggested, that EGK-glue explicitly accelerates the rejoining of tissue with a 1.86 fold increase in skin tensile strength after healing. Imparting quinone moiety to gelatin-keratin conjugates through caffeic acid and a weaker oxidizing agent provides an adhesive glue with appreciable strength, and hemocompatible, cytocompatible and biodegradable properties, which, rejoin the cut tissue ends effectively. EGK-glue obtained in the present study finds wide biomedical/clinical applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Acquire uterine vascular malformation: Clinical outcome of transarterial embolization

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chae Hoon [Dept. of Radiology, Gangneung Asan Hospital, Gangneung (Korea, Republic of); Yang, Seung Boo; Goo, Dong Erk; Kim, Yong Jae; Lee, Jae Myung; Lee, Woong Hee [Dept. of Radiology, Soonchunhyang University Gumi Hospital, Gumi (Korea, Republic of)

    2017-02-15

    To evaluate clinical outcomes of transarterial embolization of bilateral uterine arteries (UAE) in patients with acquired uterine vascular malformation (UVM). This retrospective study was performed on the medical records of all 19 patients who underwent transarterial embolization of bilateral UAE for the treatment of symptomatic UVMs from January 2003 to June 2011. Embolization was performed via the unilateral femoral artery approach with a catheter and angiographic techniques. Clinical success was defined as definitive resolution of abnormal vaginal bleeding. Post-procedural complications included all adverse events related to the embolization procedure. A total of 20 procedures were performed in 19 patients. One patient required repeat embolization because of incomplete embolization related to prominent high flow malformation. Clinically, in all patients, bleeding was controlled immediately after embolization. No complications occurred in all patients during the follow up period. In all patients who underwent successful UAE, menstrual cycles were normally restored within 1-2 months. Normal pregnancy with term delivery was observed in two of the 19 cases. Transarterial bilateral UAE is a safe and effective treatment in patients with vaginal bleeding caused by acquired UVM, and it allows the possibility of future pregnancy.

  11. Acquire uterine vascular malformation: Clinical outcome of transarterial embolization

    International Nuclear Information System (INIS)

    Kang, Chae Hoon; Yang, Seung Boo; Goo, Dong Erk; Kim, Yong Jae; Lee, Jae Myung; Lee, Woong Hee

    2017-01-01

    To evaluate clinical outcomes of transarterial embolization of bilateral uterine arteries (UAE) in patients with acquired uterine vascular malformation (UVM). This retrospective study was performed on the medical records of all 19 patients who underwent transarterial embolization of bilateral UAE for the treatment of symptomatic UVMs from January 2003 to June 2011. Embolization was performed via the unilateral femoral artery approach with a catheter and angiographic techniques. Clinical success was defined as definitive resolution of abnormal vaginal bleeding. Post-procedural complications included all adverse events related to the embolization procedure. A total of 20 procedures were performed in 19 patients. One patient required repeat embolization because of incomplete embolization related to prominent high flow malformation. Clinically, in all patients, bleeding was controlled immediately after embolization. No complications occurred in all patients during the follow up period. In all patients who underwent successful UAE, menstrual cycles were normally restored within 1-2 months. Normal pregnancy with term delivery was observed in two of the 19 cases. Transarterial bilateral UAE is a safe and effective treatment in patients with vaginal bleeding caused by acquired UVM, and it allows the possibility of future pregnancy

  12. FIBRIN GLUE DAN APLIKASINYA

    Directory of Open Access Journals (Sweden)

    Agi Harliani S

    2015-08-01

    Full Text Available Fibrin Tissue Adhesive (FTA, Fibrin Sealant (FS or Fibrin Glue (FG are names given to a group of product that lead to the formation of fibrin clot at the site of application. Fibrin Glue represents a new revolution for local haemostatic, which produced by based on the understanding about blood coagulation process. The mechanism of FG mimics the last stage of blood coagulation process. Haemophilia, is a congenital inherited bleeding disorder, characterized by repeated bleeding episodes. The basic pathology is deficiency of factor VIII (hemophilia A or factor IX (hemophilia B. At bleeding episodes, hemophilia patients need replacement therapy. Hemophilia patients need transfusion of cryoprecipitate, Fresh Frozen Plasma (FFP or factor concentrate as replacement therapy. Oral surgery, dental extraction, circumcision, and orthopedic operations are the most important indications for fibrin glue in hemophilia care. As haemostatic local, FG minimizes bleeding, reducing the need of transfusion or factor concentrate, reducing the complication of transfusion, hospitalization and cost.

  13. Safety of Synthetic Glue Used for Laparoscopic Prolapse Treatment.

    Science.gov (United States)

    Sarasa Castelló, Núria; Toth, Alexandra; Canis, Michel; Botchorishvilli, Revaz

    2017-12-29

    We detected mesh erosion and serious postoperative complications in 3 women after performing laparoscopic promontofixation (LPF) using glue for mesh fixation. Glue, largely used in hernia surgery repair, is proposed by some gynecologic surgeons because it saves time and is easier to use than traditional sutures. We report 3 cases of postoperative complications after LPF in which glue had been used and provide research in the published literature about the use of glue in LPF. A research of glue use in gynecology mesh fixation was performed through PubMed on October 2016. The search was done using the Medical Subject Heading terms "POP" & "Laparoscopy" & "surgical Mesh" and the word either "glue" or "adhesive. Only 2 articles were found: Willecocq et al [1] and Estrade et al [2]. Neither study focused on postoperative complications. In this publication, we accurately edited video surgeries with an instructive purpose. University Hospital of Clermont-Ferrand, France. Patient A, a 65-year-old woman, complained of pelvic pain and vaginal discharge 1 month after LPF (polypropylene mesh and glue had been used). Wall mesh exposure and purulent discharge were noted. She received antibiotics and underwent mesh ablation surgery; debris of the glue was easily identified. Patient B, a 65-year-old lady with previous hysterectomy consulted for a bulging feeling in her vagina (classification: cystocele +2; rectocele +3 stage). An LPF was performed using polypropylene soft nonabsorbable mesh and glue. One month later, an apical defect of vaginal epithelialization was detected; she received long estrogenic local treatment but had to undergo surgery when presenting malodorous discharge and mesh exposure. The exposed mesh was removed, and pieces of glue were identified, having avoided mesh attachment. Patient C had a previous abdominal hysterectomy and promontofixation using a polyester mesh with glue. She consulted to us for vaginal mesh erosion covered with purulent discharge 3

  14. A simple method to estimate the optimum iodine concentration of contrast material through microcatheters: hydrodynamic calculation with spreadsheet software

    International Nuclear Information System (INIS)

    Yamauchi, Teiyu; Hayashi, Toshihiko; Yamada, Takeshi; Futami, Choichiro; Tsukiyama, Yumiko; Harada, Motoko; Furui, Shigeru; Suzuki, Shigeru; Mimura, Kohshiro

    2008-01-01

    It is important to increase the iodine delivery rate (I), that is the iodine concentration of the contrast material (C) x the flow rate of the contrast material (Q), through microcatheters to obtain arteriograms of the highest contrast. It is known that C is an important factor that influences I. The purpose of this study is to establish a method of hydrodynamic calculation of the optimum iodine concentration (i.e., the iodine concentration at which I becomes maximum) of the contrast material and its flow rate through commercially available microcatheters. Iopamidol, ioversol and iohexol of ten iodine concentrations were used. Iodine delivery rates (I meas) of each contrast material through ten microcatheters were measured. The calculated iodine delivery rate (I cal) and calculated optimum iodine concentration (calculated C opt) were obtained with spreadsheet software. The agreement between I cal and I meas was studied by correlation and logarithmic Bland-Altman analyses. The value of the calculated C opt was within the optimum range of iodine concentrations (i.e. the range of iodine concentrations at which I meas becomes 90% or more of the maximum) in all cases. A good correlation between I cal and I meas (I cal = 1.08 I meas, r = 0.99) was observed. Logarithmic Bland-Altman analysis showed that the 95% confidence interval of I cal/I meas was between 0.82 and 1.29. In conclusion, hydrodynamic calculation with spreadsheet software is an accurate, generally applicable and cost-saving method to estimate the value of the optimum iodine concentration and its flow rate through microcatheters

  15. Safety and Efficacy of transarterial nephrectomy as an alternative to surgical nephrectomy

    International Nuclear Information System (INIS)

    Cho, Jooae; Shin, Ji Hoon; Yoon, Hyun Ki; Ko, Gi Young; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jin Hyoung; Sung, Kyu Bo

    2014-01-01

    To evaluate the safety and efficacy of transarterial nephrectomy, i.e., complete renal artery embolization, as an alternative to surgical nephrectomy. This retrospective study included 11 patients who underwent transarterial nephrectomy due to a high risk of surgical nephrectomy or their refusal to undergo surgery during the period from April 2002 to February 2013. Medical records and radiographic images were reviewed retrospectively to collect information regarding underlying etiologies, clinical presentations and embolization outcomes. The underlying etiologies for transarterial nephrectomy included recurrent hematuria (chronic transplant rejection [n = 3], arteriovenous malformation or fistula [n = 3], angiomyolipoma [n = 1], or end-stage renal disease [n = 1]), inoperable renal or ureteral injury (n = 2), and ectopic kidney with urinary incontinence (n 1). The technical success rate was 100%, while clinical success was achieved in eight patients (72.7%). Subsequent surgical nephrectomy was required for three patients due to an incomplete nephrectomy effect (n = 2) or necrotic pyelonephritis (n = 1). Procedure-related complications were post-infarction syndrome in one patient and necrotic pyelonephritis in another patient. Of four patients with follow-up CT, four showed renal atrophy and two showed partial renal enhancement. No patient developed a procedure-related hypertension. Transarterial nephrectomy may be a safe and effective alternative to surgical nephrectomy in patients with high operative risks.

  16. Safety and Efficacy of transarterial nephrectomy as an alternative to surgical nephrectomy

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jooae; Shin, Ji Hoon; Yoon, Hyun Ki; Ko, Gi Young; Gwon, Dong Il; Ko, Heung Kyu; Kim, Jin Hyoung; Sung, Kyu Bo [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2014-08-15

    To evaluate the safety and efficacy of transarterial nephrectomy, i.e., complete renal artery embolization, as an alternative to surgical nephrectomy. This retrospective study included 11 patients who underwent transarterial nephrectomy due to a high risk of surgical nephrectomy or their refusal to undergo surgery during the period from April 2002 to February 2013. Medical records and radiographic images were reviewed retrospectively to collect information regarding underlying etiologies, clinical presentations and embolization outcomes. The underlying etiologies for transarterial nephrectomy included recurrent hematuria (chronic transplant rejection [n = 3], arteriovenous malformation or fistula [n = 3], angiomyolipoma [n = 1], or end-stage renal disease [n = 1]), inoperable renal or ureteral injury (n = 2), and ectopic kidney with urinary incontinence (n 1). The technical success rate was 100%, while clinical success was achieved in eight patients (72.7%). Subsequent surgical nephrectomy was required for three patients due to an incomplete nephrectomy effect (n = 2) or necrotic pyelonephritis (n = 1). Procedure-related complications were post-infarction syndrome in one patient and necrotic pyelonephritis in another patient. Of four patients with follow-up CT, four showed renal atrophy and two showed partial renal enhancement. No patient developed a procedure-related hypertension. Transarterial nephrectomy may be a safe and effective alternative to surgical nephrectomy in patients with high operative risks.

  17. Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com; Ierardi, Anna Maria, E-mail: amierardi@yahoo.it; Duka, Ejona, E-mail: ejonaduka@hotmail.com [Insubria University, Department of Radiology, Interventional Radiology (Italy); Radaelli, Alessandro, E-mail: alessandro.radaelli@philips.com [Philips Healthcare (Netherlands); Floridi, Chiara, E-mail: chiara.floridi@gmail.com [Insubria University, Department of Radiology, Interventional Radiology (Italy); Bacuzzi, Alessandro, E-mail: alessandro.bacuzzi@ospedale.varese.it [University of Insubria, Anaesthesia and Palliative Care (Italy); Bucourt, Maximilian de, E-mail: maximilian.de-bucourt@charite.de [Charité - University Medicine Berlin, Department of Radiology (Germany); Marchi, Giuseppe De, E-mail: giuseppedemarchi@email.it [Insubria University, Department of Radiology, Interventional Radiology (Italy)

    2016-04-15

    BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

  18. Glue Film Thickness Measurements by Spectral Reflectance

    International Nuclear Information System (INIS)

    Marshall, B.R.

    2010-01-01

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 (micro)m, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  19. Glue Film Thickness Measurements by Spectral Reflectance

    Energy Technology Data Exchange (ETDEWEB)

    B. R. Marshall

    2010-09-20

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  20. Coil Migration after Transarterial Coil Embolization of a Splenic Artery Pseudoaneurysm

    Directory of Open Access Journals (Sweden)

    Bezawit D. Tekola

    2013-11-01

    Full Text Available A 48-year-old man with a history of splenic artery pseudoaneurysm requiring transarterial embolization 3 months earlier presented to the emergency department with abdominal pain and fever. Computed tomography showed evidence of embolization coil fragments within the gastrointestinal tract. Upper endoscopy showed a large gastric ulcer with numerous embolization coils extruding into the gastric lumen. The patient underwent partial gastrectomy, distal pancreatectomy and resection of the splenic artery pseudoaneurysm. This case illustrates a rare delayed complication of transarterial embolization of a splenic artery pseudoaneurysm.

  1. Embolization of brain arteriovenous malformations: results of 42 cases treated with N. B. C. A. and flow-guided microcatheter

    International Nuclear Information System (INIS)

    Han, Moon Hee; Chang, Kee Hyun; Kim, Dong Gyu; Lee, Sang Hyung; Han, Dae Hee

    1994-01-01

    We report the results of embolization in 42 cases of brain arteriovenous malformation and discuss the technical problems. Flow-guided microcatheter for the superselection of the feeding arteries and n-butyl cyanoacrylate as an embolic agent were used. Wire-guided microcatheter and microparticle were used in two exceptional cases. As preembolization functional evaluation, 30-50 mg of thiopental sodium solution was injected into the feeding arteries through superselected microcatheters in 40 cases with supratentorial lesions. There was no local arterial complication by injection of thiopental solution. Embolization caused a permanent neurologic deficit(mild to moderated hemiparesis) in 2 patients (4.8%) by a reflux of embolic agent or probable spasm of main arterial trunk. In 8 patients(19%), the AVMs were completely obliterated and 25 patients(60%) showed angiographic obliterations of 50-90% of the lesions. Embolization-induced venous occlusion was demonstrated at post-embolization angiography in 6 patients, and 3 patients of them showed delayed and transient neurologic deficits. Embolization of cerebral AVM can be performed effectively and safely by a superselective method and appropriate functional evaluation. Superselective thiopental sodium injection is a safe and reliable test for the evaluation of local brain function before embolization

  2. Embolization of brain arteriovenous malformations: results of 42 cases treated with N. B. C. A. and flow-guided microcatheter

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Chang, Kee Hyun; Kim, Dong Gyu; Lee, Sang Hyung; Han, Dae Hee [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-04-15

    We report the results of embolization in 42 cases of brain arteriovenous malformation and discuss the technical problems. Flow-guided microcatheter for the superselection of the feeding arteries and n-butyl cyanoacrylate as an embolic agent were used. Wire-guided microcatheter and microparticle were used in two exceptional cases. As preembolization functional evaluation, 30-50 mg of thiopental sodium solution was injected into the feeding arteries through superselected microcatheters in 40 cases with supratentorial lesions. There was no local arterial complication by injection of thiopental solution. Embolization caused a permanent neurologic deficit(mild to moderated hemiparesis) in 2 patients (4.8%) by a reflux of embolic agent or probable spasm of main arterial trunk. In 8 patients(19%), the AVMs were completely obliterated and 25 patients(60%) showed angiographic obliterations of 50-90% of the lesions. Embolization-induced venous occlusion was demonstrated at post-embolization angiography in 6 patients, and 3 patients of them showed delayed and transient neurologic deficits. Embolization of cerebral AVM can be performed effectively and safely by a superselective method and appropriate functional evaluation. Superselective thiopental sodium injection is a safe and reliable test for the evaluation of local brain function before embolization.

  3. The CostGlue XML Schema

    OpenAIRE

    Furfari, Francesco; Potort?, Francesco; Savić, Dragan

    2008-01-01

    An XML schema for scientific metadata is described. It is used for the CostGlue archival program, developed in the framework of the European Union COST Action 285: "Modelling and simulation tools for research in emerging multi-service telecommunications". The schema is freely available under the GNU LGPL license at http://wnet.isti.cnr.it/software/costglue/schema/2007/CostGlue.xsd, or at its official repository, at http://lt.fe.uni-lj. si/costglue/schema/2007/costglue.xsd.

  4. Three-dimensional glue detection and evaluation based on linear structured light

    Science.gov (United States)

    Xiao, Zhitao; Yang, Ruipeng; Geng, Lei; Liu, Yanbei

    2018-01-01

    During the online glue detection of body in white (BIW), the purpose of traditional glue detection based on machine vision is the localization and segmentation of glue, which is dissatisfactory for estimating the uniformity of glue with complex shape. A three-dimensional glue detection method based on the linear structured light and the movement parameters of robot is proposed. Firstly, the linear structured light and epipolar constraint algorithm are used for sign matching of binocular vision. Then, hand-eye relationship between robot and binocular camera is utilized to unified coordinate system. Finally, a structured light stripe extraction method is proposed to extract the sub-pixel coordinates of the light strip center. Experiments results demonstrate that the propose method can estimate the shape of glue accurately. For three kinds of glue with complex shape and uneven illumination, our method can detect the positions of blemishes. The absolute error of measurement is less than 1.04mm and the relative error is less than 10% respectively, which is suitable for online glue detection in BIW.

  5. Comparison of two fibrin glues in anastomoses and skin closure.

    Science.gov (United States)

    Park, W; Kim, W H; Lee, C H; Kim, D Y; Choi, J H; Huh, J W; Sung, H M; Kim, I S; Kweon, O K

    2002-09-01

    To control intra-operative haemorrhage, fibrin glues are preferred by many surgeons because of their biological advantages and convenience of application. Manufacturers have developed a few kinds of fibrin glues with a little difference in their composition. This study was to compare the effectiveness of two commercially available fibrin glues; Greenplast (Green Cross P. D. Company, Yongin, Korea) and Tisseel (Baxter-Immuno AG, Vienna, Austria). They were applied experimentally to several kinds of surgery in dogs - renal vessel anastomosis, partial splenectomy, intestinal anastomosis and incision skin wound - and evaluated for their haemostatic and adhesive effects. When the two glues were applied in renal vessel anastomosis, the amount of haemorrhage in artery and vein decreased significantly. They also decreased the haemorrhage in partial splenectomy. At 10 min after application of the glues to an incision skin wound, the tensile strengths developed were significantly higher than that of control. The present study indicates that two-component fibrin glues have a haemostatic effect as a mechanical barrier in renal vessel anastomosis and an adhesive effect in the early stage of incision skin wound closure, and the two glues have similar effects with no complications.

  6. Transarterial Embolization of Type II Endoleaks after EVAR: The Role of Ethylene Vinyl Alcohol Copolymer (Onyx)

    International Nuclear Information System (INIS)

    Müller-Wille, René; Wohlgemuth, Walter A.; Heiss, Peter; Wiggermann, Philipp; Güntner, Oliver; Schreyer, Andreas G.; Hoffstetter, Patrick; Stroszczynski, Christian; Zorger, Niels

    2013-01-01

    Purpose: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx). Methods: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37–83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinical success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. Result: Mean follow-up time was 26.0 (range 6–50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels. Conclusion: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory

  7. Transarterial Embolization of Type II Endoleaks after EVAR: The Role of Ethylene Vinyl Alcohol Copolymer (Onyx)

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Wille, Rene, E-mail: rene.mueller-wille@ukr.de; Wohlgemuth, Walter A., E-mail: walter.wohlgemuth@ukr.de; Heiss, Peter, E-mail: peter.heiss@ukr.de; Wiggermann, Philipp, E-mail: philipp.wiggermann@ukr.de; Guentner, Oliver, E-mail: oliverguentner@yahoo.de; Schreyer, Andreas G., E-mail: andreas.schreyer@ukr.de; Hoffstetter, Patrick, E-mail: p.hoffstetter@asklepios.com; Stroszczynski, Christian, E-mail: christian.stros@ukr.de [University Medical Center Regensburg, Department of Radiology (Germany); Zorger, Niels, E-mail: niels.zorger@barmherzige-regensburg.de [Krankenhaus Barmherzige Brueder Regensburg, Department of Radiology (Germany)

    2013-10-15

    Purpose: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx). Methods: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37-83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinical success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. Result: Mean follow-up time was 26.0 (range 6-50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels. Conclusion: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.

  8. Transarterial infusion chemotherapy with a combination of gemcitabine and 5-fluorouracil in advanced pancreatic carcinoma

    International Nuclear Information System (INIS)

    Shi Haifeng; Jin Zhengyu; Yang Ning; Liu Wei; Pan Jie; Cai Lixing; Zhao Yupei; Zhou Zhiqiang

    2002-01-01

    Objective: To retrospectively analyze the effectiveness of transarterial infusion chemotherapy of gemcitabine and 5-fluorouracil in advanced pancreatic carcinoma. Methods: Twenty-two patients with advanced pancreatic carcinoma were treated with transarterial infusion chemotherapy. Gemcitabine and 5-fluorouracil was administered to the patients via an interarterial catheter. Then the tumor response rate and clinical benefit were observed. Results: A clinical benefit was obtained in 8 patients (36.4%). The tumor response rate was 13.6%. Median survival for all the patients was 6.1 months. Median time to tumor progression was 2.9 months. Conclusion: Transarterial infusion chemotherapy with a combination of gemcitabine and 5-fluorouracil appears to have good clinical benefit and may prolong the survival time of patients with advanced pancreatic carcinoma

  9. Cost Accounting as a Tool for Increasing Cost Transparency in Selective Hepatic Transarterial Chemoembolization.

    Science.gov (United States)

    Ahmed, Osman; Patel, Mikin; Ward, Thomas; Sze, Daniel Y; Telischak, Kristen; Kothary, Nishita; Hofmann, Lawrence V

    2015-12-01

    To increase cost transparency and uncover potential areas for savings in patients receiving selective transarterial chemoembolization at a tertiary care academic center. The hospital cost accounting system charge master sheet for direct and total costs associated with selective transarterial chemoembolization in fiscal years 2013 and 2014 was queried for each of the four highest volume interventional radiologists at a single institution. There were 517 cases (range, 83-150 per physician) performed; direct costs incurred relating to care before, during, and after the procedure with respect to labor, supply, and equipment fees were calculated. A median of 48 activity codes were charged per selective transarterial chemoembolization from five cost centers, represented by the angiography suite, units for care before and after the procedure, pharmacy, and observation floors. The average direct cost of selective transarterial chemoembolization did not significantly differ among operators at $9,126.94, $8,768.77, $9,027.33, and $8,909.75 (P = .31). Intraprocedural costs accounted for 82.8% of total direct costs and provided the greatest degree in cost variability ($7,268.47-$7,691.27). The differences in intraprocedural expense among providers were not statistically significant (P = .09), even when separated into more specific procedure-related labor and supply costs. Cost accounting systems could effectively be interrogated as a method for calculating direct costs associated with selective transarterial chemoembolization. The greatest source of expenditure and variability in cost among providers was shown to be intraprocedural labor and supplies, although the effect did not appear to be operator dependent. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  10. Combined Use of an Occlusion Balloon Catheter and a Microcatheter for Embolization of the Unselectable Right Inferior Phrenic Artery Supplying Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Miyayama, Shiro; Matsui, Osamu; Taki, Keiichi; Minami, Tetsuya; Ito, Chiharu; Shinmura, Rieko; Takamatsu, Shigeyuki; Kobayashi, Miki; Notsumata, Kazuo

    2004-01-01

    We report the combined use of an occlusion balloon catheter and a microcatheter for transcatheter arterial embolization (TAE) of hepatocellular carcinoma (HCC) fed by the unselectable right inferior phrenic artery (IPA). In one case, HCC was fed by the reconstructed right IPA via a small branch arising from the proximate portion of the celiac artery. In another, the tumor was fed by the right IPA that had been previously embolized with coils. TAE was successfully performed through a microcatheter placed in the celiac artery immediately proximal to the occluding balloon catheter of the celiac trunk and coil embolization of the left gastric artery

  11. Caged Molecular Glues as Photoactivatable Tags for Nuclear Translocation of Guests in Living Cells.

    Science.gov (United States)

    Arisaka, Akio; Mogaki, Rina; Okuro, Kou; Aida, Takuzo

    2018-02-21

    We developed dendritic caged molecular glues ( Caged Glue-R) as tags for nucleus-targeted drug delivery, whose multiple guanidinium ion (Gu + ) pendants are protected by an anionic photocleavable unit (butyrate-substituted nitroveratryloxycarbonyl; BA NVOC). Negatively charged Caged Glue-R hardly binds to anionic biomolecules because of their electrostatic repulsion. However, upon exposure of Caged Glue-R to UV light or near-infrared (NIR) light, the BA NVOC groups of Caged Glue-R are rapidly detached to yield an uncaged molecular glue ( Uncaged Glue-R) that carries multiple Gu + pendants. Because Gu + forms a salt bridge with PO 4 - , Uncaged Glue-R tightly adheres to anionic biomolecules such as DNA and phospholipids in cell membranes by a multivalent salt-bridge formation. When tagged with Caged Glue-R, guests can be taken up into living cells via endocytosis and hide in endosomes. However, when the Caged Glue-R tag is photochemically uncaged to form Uncaged Glue-R, the guests escape from the endosome and migrate into the cytoplasm followed by the cell nucleus. We demonstrated that quantum dots (QDs) tagged with Caged Glue-R can be delivered efficiently to cell nuclei eventually by irradiation with light.

  12. Comparison of the intracoronary continuous infusion method using a microcatheter and the intravenous continuous adenosine infusion method for inducing maximal hyperemia for fractional flow reserve measurement.

    Science.gov (United States)

    Yoon, Myeong-Ho; Tahk, Seung-Jea; Yang, Hyoung-Mo; Park, Jin-Sun; Zheng, Mingri; Lim, Hong-Seok; Choi, Byoung-Joo; Choi, So-Yeon; Choi, Un-Jung; Hwang, Joung-Won; Kang, Soo-Jin; Hwang, Gyo-Seung; Shin, Joon-Han

    2009-06-01

    Inducing stable maximal coronary hyperemia is essential for measurement of fractional flow reserve (FFR). We evaluated the efficacy of the intracoronary (IC) continuous adenosine infusion method via a microcatheter for inducing maximal coronary hyperemia. In 43 patients with 44 intermediate coronary lesions, FFR was measured consecutively by IC bolus adenosine injection (48-80 microg in left coronary artery, 36-60 microg in the right coronary artery) and a standard intravenous (IV) adenosine infusion (140 microg x min(-1) x kg(-1)). After completion of the IV infusion method, the tip of an IC microcatheter (Progreat Microcatheter System, Terumo, Japan) was positioned at the coronary ostium, and FFR was measured with increasing IC continuous adenosine infusion rates from 60 to 360 microg/min via the microcatheter. Fractional flow reserve decreased with increasing IC adenosine infusion rates, and no further decrease was observed after 300 microg/min. All patients were well tolerated during the procedures. Fractional flow reserves measured by IC adenosine infusion with 180, 240, 300, and 360 microg/min were significantly lower than those by IV infusion (P < .05). Intracoronary infusion at 180, 240, 300, and 360 microg/min was able to shorten the times to induction of optimal and steady-stable hyperemia compared to IV infusion (P < .05). Functional significances were changed in 5 lesions by IC infusion at 240 to 360 microg/min but not by IV infusion. The results of this study suggest that an IC adenosine continuous infusion method via a microcatheter is safe and effective in inducing steady-state hyperemia and more potent and quicker in inducing optimal hyperemia than the standard IV infusion method.

  13. Transarterial embolization for hematuria caused by renal arteriovenous malformations or fistulae

    International Nuclear Information System (INIS)

    Meng Xiaoxi; Liu Shiyuan; Dong Weihua; Dong Sheng; Jia Ningyang; Xiao Xiangsheng

    2008-01-01

    Objective: To evaluate the efficacy and safety of transarterial embolization for hematuria caused by renal arteriovenous malformation or fistulae. Methods: Seven patients with gross hematuria caused by renal arterial abnormalities were retrospectively reviewed, of which three had congenital renal arteriovenous malformations and the other four had non-neoplastic acquired renal arteriovenous fistulae. All patients were confirmed by renal arterial angiography and undergone embolization with various embolic materials. Results: Embolization was successfully carried out in all cases. Gross hematuria disappeared one to seven days after the procedure. No severe complications were encountered. No recurrence occurred within 12 to 36 months of follow-up. Conclusions: Transarterial embolization is safe and effective for hematuria caused by renal arteriovenous malformations or fistulae. (authors)

  14. Compounds from silicones alter enzyme activity in curing barnacle glue and model enzymes.

    Science.gov (United States)

    Rittschof, Daniel; Orihuela, Beatriz; Harder, Tilmann; Stafslien, Shane; Chisholm, Bret; Dickinson, Gary H

    2011-02-17

    Attachment strength of fouling organisms on silicone coatings is low. We hypothesized that low attachment strength on silicones is, in part, due to the interaction of surface available components with natural glues. Components could alter curing of glues through bulk changes or specifically through altered enzyme activity. GC-MS analysis of silicone coatings showed surface-available siloxanes when the coatings were gently rubbed with a cotton swab for 15 seconds or given a 30 second rinse with methanol. Mixtures of compounds were found on 2 commercial and 8 model silicone coatings. The hypothesis that silicone components alter glue curing enzymes was tested with curing barnacle glue and with commercial enzymes. In our model, barnacle glue curing involves trypsin-like serine protease(s), which activate enzymes and structural proteins, and a transglutaminase which cross-links glue proteins. Transglutaminase activity was significantly altered upon exposure of curing glue from individual barnacles to silicone eluates. Activity of purified trypsin and, to a greater extent, transglutaminase was significantly altered by relevant concentrations of silicone polymer constituents. Surface-associated silicone compounds can disrupt glue curing and alter enzyme properties. Altered curing of natural glues has potential in fouling management.

  15. Research on preparation of phosphate-modified animal glue binder for foundry use

    Science.gov (United States)

    Wang, Tian-Shu; Liu, Wei-Hua; Li, Ying-Min

    2018-03-01

    In this paper, three phosphates were used as modifiers to modify animal glue binder. The structural characteristics and thermal properties of animal glue binder treated with phosphates were studied by Fourier transform-infrared spectroscopy, gel permeation chromatography and derivative thermogravimetric analysis. The results showed that the modified animal glue binder had better sand tensile strength and lower viscosity than untreated animal glue binder. The best modification process was as follows: the optimal amount of sodium carbonate was 4 wt% to animal glue; the optimal weight ratio of the modifiers was sodium pyrophosphate : sodium tripolyphosphate : sodium hexametaphosphate : animal glue = 3 : 3 : 4 : 100, and the optimal reaction should be performed at 80°C for a reaction time of 120 min. A final tensile strength of approximately 3.20 MPa was achieved and the viscosity value was approximately 880 mPa s.

  16. Transarterial lidocaine-lipiodol emulsion administration for relief of pain during transarterial chemoembolization of malignant tumor

    International Nuclear Information System (INIS)

    Wu Anle; Yan Zhiping; Zhou Kangrong; Wang Jianhua; Cheng Jiemin; Qian Sheng; Luo Jianjun; Chen Yi

    2004-01-01

    Objective: To assess the feasibility and efficacy of transarterial lidocaine-lipiodol emulsion administration for controlling abdominal pain and preventing the arterial spasm resulting from TACE, and to evaluate the optimal amount of lidocaine administration. Methods: In a prospective trial of 120 consecutive patients with malignant tumor who underwent TACE were divided into three groups, those who received lidocaine-lipiodol emulsion administration (group A, n=40), those who received lidocaine bolus intraarterial infusion immediately before TACE (group B, n=40) and those who received no lidocaine injection before TACE, (group C, n=40). The degree of post-procedure pain was evaluated by a subjective method (using visual analogue scales from 0 to 10), and an objective method (amount of post-procedure analgesics). Incidence and degree of arterial spasm were assessed by DSA. Results: The correlative pain incidences between the three groups showed significant difference (P 0.05). Mean dose of intramuscular analgesics for controlling intolerable pain in group A and B was significantly lower than that of group C (P<0.05). There was no difference in the incidence of arterial spasm between group A and B but it was much lower in group C. Lipiodol deposit in malignant mass was densest in group A, especially in the metastatic nodules of the liver. Conclusions: Transarterial administration of lidocaine-lipiodol emulsion can not only reduce the incidence of pain during TACE, but also prevent the arterial spasm. It is much more effective than pre-TACE administration of pethidine and intraarterial infusion of lidocaine. The authors recommond routinely for the administration of lidocaine-lipiodol emulsion. (authors)

  17. Transarterial infusion chemotherapy combined with high intensity focused ultrasound for the treatment of pancreatic carcinomas: a clinical study

    International Nuclear Information System (INIS)

    Zhang Yiping; Zhao Jingzhi; Qiao Xinrong; Huang Hankui

    2011-01-01

    Objective: To assess the clinical value of transarterial infusion chemotherapy combined with high intensity focused ultrasound (HIFU) for the treatment of pancreatic carcinomas. Methods: A total of 64 patients with inoperable pancreatic carcinomas were randomly divided into study group (n=32) and control group (n=32). Transarterial infusion chemotherapy combined with HIFU was employed in patients of study group, while simple transarterial infusion chemotherapy was conducted in patients of control group. The effective rate, the clinical benefit rate (CBR), the occurrence of side effect and the survival time of the two groups were recorded. The results were compared between the two groups. Results: The effective rate (PR + MR), the median survival time and the one-year survival rate of the study group were 55.56%, 13.0 months and 68.75% respectively, while the effective rate (PR + MR), the median survival time and the one-year survival rate of the control group were 28.57%, 9.0 months and 43.75% respectively. Both the effective rate and the one-year survival rate of the study group were significantly higher than those of the control group (P<0.05). Conclusion: Compared with pure transarterial infusion chemotherapy, transarterial infusion chemotherapy combined with HIFU can significantly improve the short-term efficacy and increase the one-year survival rate for patients with advanced pancreatic carcinomas. (authors)

  18. Risk Factors for the Development of Postembolization Syndrome after Transarterial Chemoembolization for Hepatocellular Carcinoma Treatment

    Directory of Open Access Journals (Sweden)

    Mariana Lima

    2018-01-01

    Full Text Available Introduction: Hepatic transarterial chemoembolization is a widely used technique for the treatment of hepatocellular carcinoma. The most common complication of this procedure is postembolization syndrome. The main objective of this study was to assess risk factors for the development of postembolization syndrome. Material and Methods: Single-centre retrospective analysis of 563 hepatic transarterial chemoembolization procedures from January 1st, 2014 – December 31st, 2015. Hepatic transarterial chemoembolization was performed with ½ - 2 vials of 100 - 300 μm microspheres loaded with doxorubicin. Patients who experienced postembolization syndrome were identified based on prolongation of hospitalization due to pain, fever, nausea and/or vomiting. A control group with the patients who did not have postembolization syndrome was randomly created (three controls for one case. Descriptive analysis and multivariate logistic regression were performed. Results: The overall prevalence of postembolization syndrome was 6.2%. Hepatic transarterial chemoembolization with doxorubicin dosage above 75 mg (more than one vial, the size of the largest nodule and female gender had statistically significant relation with development of postembolization syndrome (p = 0.030, p = 0.046 and p = 0.037, respectively. Discussion: Doxorrubicin dosage above 75 mg is associated with a higher risk of postembolization syndrome. This result can be helpful for decision-making in clinical practice, whenever it is possible to avoid a higher dose without compromising the efficacy of the treatment. The size of the largest nodule and female gender also constitute risk factors for postembolization syndrome. The other variables studied were not related to the development of postembolization syndrome. Conclusion: The dose of doxorrubicin, the size of the largest nodule treated and female gender are potential risk factors for the development of postembolization syndrome after hepatic

  19. Fibrin glue as agent for sealing corneal and conjunctival wound leaks.

    Science.gov (United States)

    Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S

    2018-02-01

    PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.

  20. Effectiveness of Fibrin Glue in Adherence of Skin Graft.

    Science.gov (United States)

    Reddy, Konda Sireesha; Chittoria, Ravi Kumar; Babu, Preethitha; Marimuthu, Senthil Kumaran; Kumar, Sudhanva Hemanth; Subbarayan, Elan Kumar; Chavan, Vinayak; Mohapatra, Devi Prasad; Sivakumar, Dinesh Kumar; Friji, M T

    2017-01-01

    Graft fixation is important for graft take. Fibrin glue has been proposed as an ideal material, because of its human origin and it provides firm adhesion in seconds or minutes. To evaluate the efficiency of fibrin glue, in increasing the take of skin graft. Assessment includes surgical time taken for graft fixation, haematoma/seroma formation, engraftment and wound closure by day 14. The study is an observational prospective study conducted in the Department of Plastic Surgery, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, from January 2016 to June 2016. Sixteen patients who underwent split skin grafting were assessed during the study period. Fibrin glue was used on the recipient bed before grafting. Better haemostasis and graft adhesion, with a significant reduction of surgical time, were noted. The safety profile of fibrin glue was excellent as indicated by the lack of any related serious adverse experiences. These findings demonstrate that it is safe and effective for attachment of skin grafts, with outcomes at least as good as conventional methods.

  1. The road less traveled: transarterial embolization of dural arteriovenous fistulas via the ascending pharyngeal artery.

    Science.gov (United States)

    Gross, Bradley A; Albuquerque, Felipe C; Moon, Karam; McDougall, Cameron G

    2017-01-01

    With the introduction of Onyx, transarterial embolization has become the most common endovascular approach to treating dural arteriovenous fistulas (dAVFs), often via the middle meningeal or occipital arteries. The ascending pharyngeal artery (APA) is a less frequently explored transarterial route because of its small caliber, potential anastomoses to the internal carotid and vertebral arteries, and vital supply to lower cranial nerves. To review our institutional experience and highlight the prevalence of APA supply to dAVFs and cases where it is a safe and effective pedicle for embolization. We reviewed our endovascular database (January 1, 1996 to March 1, 2016) for cranial dAVFs, evaluating dAVF characteristics and embolization results for those treated transarterially via the APA. Of 267 endovascularly treated dAVFs, 68 had APA supply (25%). Of these 68 dAVFs, embolization was carried out via this pedicle in 8 (12%) and 7 were ultimately occluded. No complications, including post-treatment cranial neuropathies or radiographic evidence of non-target embolization, were found. For 5 dAVFs, the APA was selected as the initial pedicle for embolization (two marginal sinus, one distal sigmoid, one cavernous, one tentorial). In four of these five cases, dAVF occlusion was achieved via the initial APA feeding artery pedicle. In one case, near-complete, stagnant occlusion was achieved after APA embolization; complete occlusion was achieved after adjunctive embolization of a single additional middle meningeal artery pedicle. In three other cases of complex transverse/sigmoid dAVFs, the APA was used after multiple attempts via middle meningeal and occipital artery pedicles. Occlusion was not achieved transarterially; two of these three dAVFs were ultimately occluded transvenously. In rare, select cases, the APA is an excellent route for transarterial embolization of cranial dAVFs. Published by the BMJ Publishing Group Limited. For permission to use (where not already

  2. Fluoroscopy-guided endovenous sclerotherapy using a microcatheter prior to endovenous laser ablation: Comparison between liquid and foam sclerotherapy for varicose tributaries

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chee, Hyun Keun; Chang, Il Soo [Konkuk University Hospital, Konkuk University School of Medicine, Seoul (Korea, Republic of)

    2014-08-15

    To compare the efficacy and adverse effects of endovenous foam sclerotherapy (EFS) and liquid sclerotherapy (ELS) using a microcatheter for the treatment of varicose tributaries. From December 2007 to January 2009, patients with venous reflux in the saphenous vein were enrolled. The foam or liquid sclerosant was injected through a microcatheter just before endovenous laser ablation (EVLA). Patients were evaluated for the technical success, clinical success, and procedure-related complications during the procedure and follow-up visits. A total of 94 limbs were included: 48 limbs (great saphenous vein [GSV], 35; small saphenous vein [SSV], 13) were managed using EFS and EVLA (foam group; FG), and 46 limbs (GSV, 37; SSV, 9) were treated by ELS and EVLA (liquid group; LG). Varicose tributaries demonstrated complete sclerosis in 92.7% with FG and in 71.8% with LG (p = 0.014). Bruising (78.7% in FG vs. 73.2% in LG, p > 0.05), pain or tenderness (75.6% in FG vs. 51.2% in LG, p = 0.0237) were noted. Hyperpigmentation (51.2% in FG vs. 46.2% in LG, p > 0.05) was found. Endovenous foam sclerotherapy using a microcatheter is more effective than ELS for eliminating remnant varicose tributaries prior to EVLA. However, EFS is more commonly associated with local complications such as pain or tenderness than ELS. Furthermore, both techniques seem to prolong the duration of hyperpigmentation along with higher costs.

  3. Transarterial chemoembolization with drug-eluting beads for hepatocellular carcinoma: its research progress

    International Nuclear Information System (INIS)

    Zhao Yan; Han Guohong; Bai Wei; Fan Daiming

    2012-01-01

    Transarterial chemoembolization (TACE) has been the main treatment for patients with intermediate-stage hepatocellular carcinoma (HCC). However, the clinical application of TACE is limited due to the technical deficiencies, such as uncontrolled local drug delivery and systemic toxicity. Recently, the new drug-eluting beads (DEB), loading with doxorubicin, have be used in the TACE procedures. This new technique can not only maintain the local drug level for quite a long time and thus get a higher objective response, but also decrease the systemic toxicity. Transarterial chemoembolization with drug-eluting beads (DEB-TACE) have already been widely used abroad, and more related clinical trials are underway to clarify its advantages. This paper aims to make a comprehensive review in the respects of its characteristics and the latest research progress in DEB-TACE. (authors)

  4. A rare case of empyema developed after transarterial chemoembolization for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sur, Young Keun; Won, Je Hwan; Hwang, Hee Jung; Kim, Jinoo [Ajou University Hospital, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2015-01-15

    A 60-year-old male patient who previously underwent transarterial chemoembolization for recurrent hepatocellular carcinoma three months ago presented to the emergency department with pleural effusion and hemoptysis. On serial review of plain radiographs and chest CT, transdiaphragmatic migration of Lipiodol from the treated area of the liver into the ipsilateral pleural cavity was demonstrated. The patient consequently developed empyema in the right thorax. Therefore, percutaneous drainage was performed. Empyema and pleural effusion regressed after 10 days of medical treatment and drainage. After that, the patient was transferred back to the local clinic upon full symptomatic recovery. Herein, we describe a rare complication of transarterial chemoembolization for hepatocellular carcinoma manifesting as an empyema secondary to the migration of the ethiodized oil content from the liver into the ipsilateral pleural cavity.

  5. Observations on dimensional changes of sized canvas based on glue temperature

    DEFF Research Database (Denmark)

    Krarup Andersen, Cecil

    2008-01-01

    The aim of this study was to explore dimensional changes caused by water on sized canvas. Samples of new linen canvas were mounted on a rig for biaxial tensioning, holding a constant stress of 100 N/m in both weave directions. The samples were then sized with respectively warm fluent glue (45 °C......) or a cold gel (20 °C), both consisting of a 5 percent sheepskin glue extracted from parchment clippings. The warm glue was absorbed into the canvas structure, whereas the cold gel mostly stayed as a discrete layer on the canvas. Twice the amount of glue was therefore needed for the warm sizing. When...... of size layers during application is important to the dimensional reaction of a canvas painting that is exposed to water....

  6. Effect of MHEC on evaporation and hydration characteristics of glue mortar

    NARCIS (Netherlands)

    Faiyas, A.P.A.; Erich, S.J.F.; Huinink, H.P.; Adan, O.C.G; Nijland, T.G.

    2016-01-01

    The influence of methylhydroxyethylcellulose (MHEC) on both moisture distribution and hydration characteristics of glue mortar using nuclear magnetic resonance imaging (NMR) is investigated. MHEC is added to glue mortar in order to control the drying rate by increasing the open time. Besides drying,

  7. Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery

    Directory of Open Access Journals (Sweden)

    Langer, Stefan

    2015-12-01

    Full Text Available Aim: Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case.Patients and methods: A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps.Results: The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis.Conclusion: Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery.

  8. Endovascular treatment of type II endoleak following thoracic endovascular aortic repair for thoracic aortic aneurysm: Case report of squeeze technique to reach the aneurysmal sac

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Hyun Jung; Kim, Chang Won; Lee, Tae Hong; Song, Seung Hwan; Lee, Chung Won; Chung, Sung Woon [Pusan National University Hospital, School of Medicine, Pusan National University, Busan (Korea, Republic of)

    2014-12-15

    Type II endoleaks are common after thoracic endovascular aortic repair (TEVAR). Various strategies are introduced to manage type II endoleaks, such as the use of coils, plugs, or liquid embolic agents (histoacryl, thrombin, onyx, etc.) through a transarterial approach or a direct puncture of the aneurysmal sac. We herein report a case of a type II endoleak caused by reverse blood flow through intercostal artery after TEVAR which was successfully treated with n-butyl cyanoacrylate (histoacryl)-lipiodol mixture by a squeeze technique to reach the aneurismal sac using a microcatheter.

  9. Control of DNA hybridization by photoswitchable molecular glue.

    Science.gov (United States)

    Dohno, Chikara; Nakatani, Kazuhiko

    2011-12-01

    Hybridization of DNA is one of the most intriguing events in molecular recognition and is essential for living matter to inherit life beyond generations. In addition to the function of DNA as genetic material, DNA hybridization is a key to control the function of DNA-based materials in nanoscience. Since the hybridization of two single stranded DNAs is a thermodynamically favorable process, dissociation of the once formed DNA duplex is normally unattainable under isothermal conditions. As the progress of DNA-based nanoscience, methodology to control the DNA hybridization process has become increasingly important. Besides many reports using the chemically modified DNA for the regulation of hybridization, we focused our attention on the use of a small ligand as the molecular glue for the DNA. In 2001, we reported the first designed molecule that strongly and specifically bound to the mismatched base pairs in double stranded DNA. Further studies on the mismatch binding molecules provided us a key discovery of a novel mode of the binding of a mismatch binding ligand that induced the base flipping. With these findings we proposed the concept of molecular glue for DNA for the unidirectional control of DNA hybridization and, eventually photoswitchable molecular glue for DNA, which enabled the bidirectional control of hybridization under photoirradiation. In this tutorial review, we describe in detail how we integrated the mismatch binding ligand into photoswitchable molecular glue for DNA, and the application and perspective in DNA-based nanoscience.

  10. Event based uncertainty assessment in urban drainage modelling, applying the GLUE methodology

    DEFF Research Database (Denmark)

    Thorndahl, Søren; Beven, K.J.; Jensen, Jacob Birk

    2008-01-01

    of combined sewer overflow. The GLUE methodology is used to test different conceptual setups in order to determine if one model setup gives a better goodness of fit conditional on the observations than the other. Moreover, different methodological investigations of GLUE are conducted in order to test......In the present paper an uncertainty analysis on an application of the commercial urban drainage model MOUSE is conducted. Applying the Generalized Likelihood Uncertainty Estimation (GLUE) methodology the model is conditioned on observation time series from two flow gauges as well as the occurrence...... if the uncertainty analysis is unambiguous. It is shown that the GLUE methodology is very applicable in uncertainty analysis of this application of an urban drainage model, although it was shown to be quite difficult of get good fits of the whole time series....

  11. Krazy Glue® in the ear: A case report of child abuse.

    Science.gov (United States)

    Sorichetti, Brendan D; Fandiño, Marcela; Kozak, Frederick K

    2018-06-01

    Krazy Glue ® or cyanoacrylate glue is an acrylic resin that polymerizes in less than a minute when in contact with moisture or water. We present a case of a one month old referred to our tertiary pediatric otolaryngology clinic from an outside emergency department with a history of application of cyanoacrylate glue in the external ear canals. This report presents the management of this case along with the medical and legal outcomes surrounding this case of child abuse. Copyright © 2018. Published by Elsevier B.V.

  12. Information-provider scripts for GLUE2 and RAID configurations.

    CERN Document Server

    Kalimeris, Dimitrios

    2014-01-01

    This report will outline two projects that were done as part of a three months long summer internship at CERN. In the first project we dealt with Worldwide LHC Computing Grid (WLCG) and its information system. The information system currently conforms to a schema called GLUE and it is evolving towards a new version: GLUE2. The aim of the project was to develop and adapt the current information system of the WLCG, used by the Large Scale Storage Systems at CERN (CASTOR and EOS), to the new GLUE2 schema. During the second project we investigated different RAID configurations so that we can get performance boost from CERN's disk systems in the future. RAID 1 that is currently in use is not an option anymore because of limited performance and high cost. We tried to discover RAID configurations that will improve the performance and simultaneously decrease the cost.

  13. On the glue content in heavy quarkonia

    International Nuclear Information System (INIS)

    Gromes, D.

    2003-01-01

    Starting with two coupled Bethe-Salpeter equations for the quark-antiquark, and for the quark-glue-antiquark component of the quarkonium, we solve the bound state equations perturbatively. The resulting admixture of glue can be partially understood in a semiclassical way; one has, however, to take care of the different use of time ordered versus retarded Green functions. Subtle questions concerning the precise definition of the equal time wave function arise, because the wave function for the Coulomb gluon is discontinuous with respect to the relative time of the gluon. A striking feature is that a one loop non-abelian graph contributes to the same order as tree graphs, because the couplings of transverse gluons in the tree graphs are suppressed in the non-relativistic bound state, while the higher order loop graph can couple to quarks via non-suppressed Coulomb gluons. We also calculate the amplitude for quark and antiquark at zero distance in the quark-glue-antiquark component of the P-state. This quantity is of importance for annihilation decays of P-states. It shows a remarkable compensation between the tree graph and the non-abelian loop graph contribution. An extension of our results to include non-perturbative effects is possible. (orig.)

  14. Guidewire and microcatheter utilization patterns during antegrade wire escalation in chronic total occlusion percutaneous coronary intervention: Insights from a contemporary multicenter registry.

    Science.gov (United States)

    Karatasakis, Aris; Tarar, Muhammad Nauman J; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Yeh, Robert W; Jaffer, Farouc A; Wyman, R Michael; Lombardi, William L; Grantham, J Aaron; Kandzari, David E; Lembo, Nicholas J; Moses, Jeffrey W; Kirtane, Ajay J; Parikh, Manish; Garcia, Santiago; Doing, Anthony; Pershad, Ashish; Shah, Alpesh; Patel, Mitul; Bahadorani, John; Shoultz, Charles A; Danek, Barbara A; Thompson, Craig A; Banerjee, Subhash; Brilakis, Emmanouil S

    2017-03-01

    We sought to describe contemporary guidewire and microcatheter utilization for antegrade wire escalation (AWE) during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Equipment utilization for AWE has been variable and evolving over time. We examined device utilization during 694 AWE attempts in 679 patients performed at 15 experienced US centers between May 2012 and April 2015. Mean age was 65.6 ± 9.7 years, and 85% of the patients were men. Successful wiring occurred in 436 AWE attempts (63%). Final technical and procedural success was 91% and 89%, respectively. The mean number of guidewire types used for AWE was 2.2 ± 1.4. The most frequently used guidewire types were the Pilot 200 (Abbott Vascular, 56% of AWE procedures), Fielder XT (Asahi Intecc, 45%), and the Confianza Pro 12 (Asahi Intecc, 28%). The same guidewires were the ones that most commonly crossed the occlusion: Pilot 200 (36% of successful AWE crossings), Fielder XT (20%), and Confianza Pro 12 (11%). A microcatheter or over-the-wire balloon was used for 81% of AWE attempts; the Corsair microcatheter (Asahi Intecc) was the most commonly used (44%). No significant association was found between guidewire type and incidence of major adverse cardiac events (MACE). Our contemporary, multicenter CTO PCI registry demonstrates that the most commonly used wires for AWE are polymer-jacketed guidewires. "Stiff" and polymer-jacketed guidewires appear to provide high crossing rates without an increase in MACE or perforation, and may thus be considered for upfront use. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Glue versus suture for mesh fixation in inguinal hernia repair.

    Science.gov (United States)

    Chandrasekar, Shruthi; Jeyakumar, S; Ganapathy, Tharun

    2018-03-22

    Inguinal hernia is one of the most common surgical problem presenting to the surgical OPD. Surgery is the mainstay of treatment for inguinal hernia today. Surgery for inguinal hernia has undergone a great evolution over a period of several centuries. Lichenstein's tension free hernioplasty is the one of the first surgeries taught to a surgical resident. The main aim of surgeries in this era is to give the best possible results with the least possible pain, scar and time. This has given rise to so many modifications to the classical Lichenstein's procedure and also to laparoscopic hernioplasty. Pain after inguinal hernia surgery is found to be debilitating and altering the quality of life in several patients, which has been attributed to the traumatic fixation of the mesh with sutures. This has paved way to the development of various atraumatic methods of fixation, tissue glue is one such development. Hence this study, to compare traumatic and atraumatic methods of mesh fixation in inguinal hernia repair. The aim of this study was to compare suture fixation versus tissue glue fixation of the mesh in inguinal hernia repair. Primary objective was to compare the immediate and chronic post-operative pain. Secondary objective was to compare the time taken for the procedure by the two methods in use and also to compare the presence of any complications. and methodology: This study was done in the General Surgery department of XXX hospital, medical college and research centre, kattangulathur after Ethics committee clearance. It is a single blinded study. The study was done on 51 patients consenting for the study and meeting the inclusion criterias from the period of March 2016 to August 2017 out of which 26 were selected for glue mesh fixation and 25 for suture mesh fixation according to simple randomization. The suture group patients underwent classical Lichenstein's tension free hernioplasty and the glue group underwent Lichenstein's hernioplasty with glue where dots of

  16. Glue detection based on teaching points constraint and tracking model of pixel convolution

    Science.gov (United States)

    Geng, Lei; Ma, Xiao; Xiao, Zhitao; Wang, Wen

    2018-01-01

    On-line glue detection based on machine version is significant for rust protection and strengthening in car production. Shadow stripes caused by reflect light and unevenness of inside front cover of car reduce the accuracy of glue detection. In this paper, we propose an effective algorithm to distinguish the edges of the glue and shadow stripes. Teaching points are utilized to calculate slope between the two adjacent points. Then a tracking model based on pixel convolution along motion direction is designed to segment several local rectangular regions using distance. The distance is the height of rectangular region. The pixel convolution along the motion direction is proposed to extract edges of gules in local rectangular region. A dataset with different illumination and complexity shape stripes are used to evaluate proposed method, which include 500 thousand images captured from the camera of glue gun machine. Experimental results demonstrate that the proposed method can detect the edges of glue accurately. The shadow stripes are distinguished and removed effectively. Our method achieves the 99.9% accuracies for the image dataset.

  17. Glue therapy in hemoptysis: A new technique

    Directory of Open Access Journals (Sweden)

    Rakesh K Chawla

    2012-01-01

    Full Text Available Hemoptysis is defined as the spitting of blood derived from the lungs or bronchial tubes as a result of pulmonary or bronchial hemorrhage. There is a large chunk of patients with hemoptysis who do not respond to conservative treatment including use of cough suppressants, antibiotics, vitamin C, hemostatics, and anxiolytics. The advanced management of such a situation is bronchial artery embolization (BAE or open thoracic surgery, which is often not possible. We have attempted a cheap, effective, and safe alternative in the form of intrabronchial instillation of glue (n-butyl cyanoacrylate under vision with the help of a therapeutic video bronchoscope (OLYMPUS T-180. The glue is instilled through a polyethylene catheter placed through the working channel of the video bronchoscope.

  18. [Hepatobronchial Fistula and Lung Abscess after Transarterial Chemoembolization].

    Science.gov (United States)

    Lee, Kwanjoo; Song, Jeong Eun; Jeong, Hyang Sook; Kim, Do Young

    2017-05-25

    Transarterial chemoembolization (TACE) is a common treatment modality to locally manage hepatocellular carcinoma. Liver abscess and bile duct injury are common complications of TACE. However, hepatobronchial fistula is a rare complication. Herein, we report a case of lung abscess due to hepatobronchial fistula after TACE. A 67-year-old man, who had underwent TACE 6 months ago, presented cough and bile-colored sputum. He was diagnosed with lung abscess and hepatobronchial fistula. We performed endoscopic retrograde cholangiopancreatography; however, there was no improvement in his symptoms. Thereafter, partial hepatectomy and repair of fistula were successively conducted.

  19. Photoinduced Bioorthogonal 1,3-Dipolar Poly-cycloaddition Promoted by Oxyanionic Substrates for Spatiotemporal Operation of Molecular Glues.

    Science.gov (United States)

    Hatano, Junichi; Okuro, Kou; Aida, Takuzo

    2016-01-04

    PGlue(PZ), a pyrazoline (PZ)-based fluorescent adhesive which can be generated spatiotemporally in living systems, was developed. Since PGlue(PZ) carries many guanidinium ion (Gu(+)) pendants, it strongly adheres to various oxyanionic substrates through a multivalent salt-bridge interaction. PGlue(PZ) is given by bioorthogonal photopolymerization of a Gu(+)-appended monomer (Glue(TZ)), bearing tetrazole (TZ) and olefinic termini. Upon exposure to UV light, Glue(TZ) transforms into a nitrileimine (NI) intermediate (Glue(NI)), which is eligible for 1,3-dipolar polycycloaddition. However, Glue(NI) in aqueous media can concomitantly be deactivated into Glue(WA) by the addition of water, and the polymerization hardly occurs unless Glue(NI) is concentrated. We found that, even under high dilution, Glue(NI) is concentrated on oxyanionic substrates to a sufficient level for the polymerization, so that their surfaces can be point-specifically functionalized with PGlue(PZ) by the use of a focused beam of UV light. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Efficacy and safety of two different n-butyl-2-cyanoacrylates for the embolization of varicoceles: a prospective, randomized, blinded study.

    Science.gov (United States)

    Vanlangenhove, Peter; De Keukeleire, Katrien; Everaert, Karel; Van Maele, Georges; Defreyne, Luc

    2012-06-01

    This was a prospective, randomized, blinded comparative study of the efficacy and safety of two different n-butyl-2-cyanoacrylates (NBCAs) for embolization of varicoceles. A total of 112 insufficient spermatic veins (left-sided, n=84; right-sided, n=28) that were diagnosed in 83 adult males were prospectively randomized for blinded embolization with NBCA (n=54; Histoacryl, Braun, Germany) or NBCA-MS (n=58; Glubran2, General Enterprise Marketing, Viareggio, Lucca, Italy). Handling, embolic efficacy, and safety of both NBCAs were compared according the fulfillment of a standardized embolization plan, the occlusive effect on the spermatic vein, and the sticking to the microcatheter. Statistical analysis was performed with the Mann-Whitney U test and the Fisher's exact test. Patients of both study arms were comparable for age and clinical indication. Spermatic vein characteristics were comparable for varicocele classification and embolization side. Both NBCAs were equally efficient in occluding the spermatic vein and blocking reflux (NBCA, n=54/54, 100% vs. NBCA-MS, n=54/57, 94.7%; P=0.244). The embolization plan could be accomplished in an equal number of veins for both groups (NBCA, n=45/54, 83.3% vs. NBCA-MS, n=41/58, 70.7%; P=0.124). Adhesiveness of the glue to the microcatheter was the same in both NBCA groups (NBCA, n=25/54, 46.3% vs. NBCA-MS, n=29/58, 50%; P=0.71). No glue-related complications were noted. NBCA and NBCA-MS are equally efficient and safe glues for embolization of varicoceles.

  1. Measurement of radiation damage on an epoxy-based optical glue

    International Nuclear Information System (INIS)

    Huang, H.C.; Peng, K.C.; Sahu, S.K.; Ueno, K.; Chang, Y.H.; Wang, C.H.; Hou, W.S.

    1997-01-01

    We measured the radiation damage on an optical glue called Eccobond-24, which is a candidate for CsI and BGO crystal calorimeters of the BELLE detector of the KEK B-factory. Absorption spectrophotometry in the range 300-800 nm was used to monitor the radiation damage. The maximum equivalent dose was 1.64 Mrad. The glue shows effects of damage, but is acceptable for the radiation level in the above-mentioned experiment. (orig.)

  2. Noncontrast chest computed tomography immediately after transarterial chemoembolization in patients with hepatocellular carcinoma: Clinical benefits and effect of radiation reduction on image quality in low-dose scanning

    International Nuclear Information System (INIS)

    Choi, Joon-Il; Kim, Hyun Beom; Kim, Min Ju; Lee, Jong Seok; Koh, Young Whan; An, Sang Bu; Ko, Heung-kyu; Park, Joong-Won

    2011-01-01

    Purpose: To evaluate the clinical benefits of noncontrast chest computed tomography (CT) immediately after transarterial chemoembolization in patients with hepatocellular carcinoma and to assess the effect of radiation reduction on image quality in low-dose scanning. Materials and methods: From June to October 2010, we performed standard-dose, noncontrast chest CTs immediately after transarterial chemoembolization in 160 patients and low-dose CTs in 88 patients. We reviewed the entire noncontrast chest CTs and follow-up CTs to reveal the clinical benefits of CT evaluation immediately after transarterial chemoembolization. Using two independent readers, we also retrospectively evaluated the radiation dose and image quality in terms of the image noise, contrast between the liver parenchyma and iodized oil and diagnostic acceptability for the evaluation of treatment response after transarterial chemoembolization. Results: In 5.2% of the patients, additional treatment was performed immediately after the interpretation of the noncontrast chest CT, and additional pulmonary lesions were found in 8.5% of the patients. The measured mean dose-length product for the low-dose scanning was 18.4% of that of the standard-dose scanning. The image noise was significantly higher with the low-dose scanning (p < 0.001). However, all of the low-dose CT scans were diagnostically acceptable, and the mean scores for the subjective assessments of the contrast and diagnostic acceptability showed no significant differences for either reader. Conclusion: A noncontrast chest CT immediately after transarterial chemoembolization has some clinical benefits for immediate decision making and detecting pulmonary lesions. Low-dose, noncontrast chest CTs immediately after transarterial chemoembolization consistently provide diagnostically acceptable images and information on treatment response in patients who have undergone transarterial chemoembolization.

  3. Transarterial Fiducial Marker Placement for Image-guided Proton Therapy for Malignant Liver Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Kengo, E-mail: yesterday.is.yesterday@gmail.com; Shimohira, Masashi, E-mail: mshimohira@gmail.com [Nagoya City University Graduate School of Medical Sciences, Department of Radiology (Japan); Sasaki, Shigeru, E-mail: ssasaki916@yahoo.co.jp; Iwata, Hiromitsu, E-mail: h-iwa-ncu@nifty.com; Nishikawa, Hiroko, E-mail: piroko1018@gmail.com; Ogino, Hiroyuki, E-mail: oginogio@gmail.com; Hara, Masaki, E-mail: mhara@med.nagoya-cu.ac.jp [Nagoya City West Medical Center, Department of Radiation Oncology, Nagoya Proton Therapy Center (Japan); Hashizume, Takuya, E-mail: tky300@gmail.com; Shibamoto, Yuta, E-mail: yshiba@med.nagoya-cu.ac.jp [Nagoya City University Graduate School of Medical Sciences, Department of Radiology (Japan)

    2015-10-15

    PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success rates of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors.

  4. Transarterial Fiducial Marker Placement for Image-guided Proton Therapy for Malignant Liver Tumors

    International Nuclear Information System (INIS)

    Ohta, Kengo; Shimohira, Masashi; Sasaki, Shigeru; Iwata, Hiromitsu; Nishikawa, Hiroko; Ogino, Hiroyuki; Hara, Masaki; Hashizume, Takuya; Shibamoto, Yuta

    2015-01-01

    PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success rates of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors

  5. Glue from the Sea:Biomedical Adhesives Inspired by Algal Polymers

    Institute of Scientific and Technical Information of China (English)

    H.Bianco-Peled; R.Bitton; P.Potin

    2007-01-01

    1 Introduction Tissue repair following surgery or trauma has been dominated by sutures,staples and wiring.Although these techniques are well established and widely used,their application often involves pain,unaesthetic results,or bleeding. These limitations emphasize the need for adhesive products to be available to surgeons.2 ResultsA challenging aspect of developing new tissue adhesive is to create a material that can glue wet surfaces.The success of synthetic glues under such an environment is very ...

  6. Use of Glubran 2 acrylic glue in interventional neuroradiology

    International Nuclear Information System (INIS)

    Raffi, L.; Simonetti, L.; Cenni, P.; Leonardi, M.

    2007-01-01

    Glubran 2 is a cyanoacrylate-based synthetic glue modified by the addition of a monomer synthesized by the manufacturer. With this material it is possible to obtain the stability of endovascular embolization that is needed to treat tumours and vascular disease. We report our 3-year experience of the use of Glubran for treating extracerebral tumours, spinal tumours, spinal arteriovenous malformations, and brain and spine dural fistulae. Glubran 2 was diluted with Lipiodol and injected in a continuous column with the flow rate monitored by seriography. The injection was stopped when retrograde flow was displayed in the afferent vessel. There were no periprocedural or subsequent clinical complications and the glue resulted in successful selective permanent occlusion with intralesional penetration similar to the angiographic features of microcatheterization. The embolization procedure was technically straightforward and relatively safe. However, Glubran 2 can be difficult to use and the procedure does carry major risks for patients. Glue injection requires in-depth study of the lesion, its circulation and the collateral circulation to avoid severe complications due to inappropriate use. (orig.)

  7. Determination of fibrin glue with antibiotics on collagen production in colon anastomosis

    Directory of Open Access Journals (Sweden)

    Stanojković Zoran

    2008-01-01

    Full Text Available Background/Aim. Fibrin glue is used as a matrix for local application of antibiotics. The aim of this study was to determine whether application of fibrin glue in combination with antibiotics can strengthen collagen production, prevent dehiscence of colon anastomoses due to infection, and reduce frequency of mortality and morbidity comparing to the control group and the group with fibrin glue application. Methods. The adult male Wistar rats divided into three groups were used in the experiment. The group 1 was the control one (after partial colon resection, colonic anastomoses performed were not treated, while to the group 2 and the group 3 were applied fibrin glue and fibrin glue with antibiotics (clindamycin and ceftriaxon on the site of anastomoses, respectively. Quality of colonic anastomoses were estimated by means of determination of collagen (L-hydroxyproline amount in the collon wall with anastomoses and histological analysis of this colon segment using light and electronic microscope on the days 5, 7 and 13 postoperatively. Results. The highest morbidity rate was registered in the group 1 (30%, then in the group 2 (13.3% and the lowest one in the group 3 (3.33%; p < 0,05 vs group 1. Mortality rate was significantly higher in the group 1 than in the group 3 (20% and 0%, respectively; p < 0,05. In the postoperative course, the highest concentrations of collagen in the colon wall on the site of anastomoses, which was confirmed by both light and electronic microscopy, were found in the group 3. Conclusion. The application of fibrin glue with antibiotics on colon anastomoses reduces the number of dehiscence, provides good mechanical protection and shorten the time of anastomoses healing.

  8. Successful Transarterial Guglielmi Detachable Coil Embolization of Post-Traumatic Fistula between a Posterior Communicating Artery Aneurysm and the Cavernous Sinus

    Science.gov (United States)

    Chen, Y.; Jiang, D-Y.; Tan, H-Q.; Wang, L-H.; Chen, X-Y.; Sun, J-H.

    2009-01-01

    Summary We describe a case of a post-traumatic posterior communicating artery (PCoA) aneurysmcavernous sinus fistula, which is an extremely rare complication of craniocerebral trauma, successfully treated with endosaccular coil embolization via transarterial route. Endosaccular embolization with Guglielmi detachable coils via transarterial route appears to be a feasible, effective and minimally invasive option for the treatment of post-traumatic fistula between the PCoA aneurysm with a small ostia and the cavernous sinus in the subacute phase. PMID:20465883

  9. Comparação das técnicas transarterial e de estimulação de múltiplos nervos para bloqueio do plexo braquial por via axilar usando lidocaína com epinefrina Comparación de las técnicas transarterial y de estimulación de múltiples nervios para bloqueo del plexo braquial por vía axilar usando lidocaína con epinefrina Comparison of transarterial and multiple nerve stimulation techniques for axillary block using lidocaine with epinephrine

    Directory of Open Access Journals (Sweden)

    Luiz Eduardo Imbelloni

    2005-02-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A técnica transarterial com grandes doses de anestésico local resulta em alta efetividade para o bloqueio axilar do plexo braquial. A técnica utilizando múltiplos estímulos exige mais tempo e maior experiência. Este estudo prospectivo compara a latência e o índice de sucesso do bloqueio do plexo braquial usando duas técnicas de localização: transarterial ou múltipla estimulação dos nervos. MÉTODO: A lidocaína com epinefrina, 800 mg, foi usada inicialmente para o bloqueio axilar. No grupo transarterial, 30 mL de lidocaína a 1,6% com epinefrina foram injetados profundamente e 20 mL superficialmente à artéria axilar. No grupo de múltipla estimulação, três nervos foram localizados eletricamente e bloqueados com volumes 20 mL, 20 mL e 10 mL da solução. O bloqueio foi considerado efetivo quando a analgesia estava presente em todos os nervos na área distal ao cotovelo. RESULTADOS: O tempo de latência (8,8 ± 2,3 min versus 10,2 ± 2,4 min; p-valor = 0,010 foi significativamente menor no grupo transarterial. Bloqueios sensitivos completos nos quatro nervos (mediano, ulnar, radial e musculocutâneo foram obtidos em 92,5% versus 83,3% no grupo de múltipla estimulação e acesso transarterial, respectivamente sem diferença significativa (p-valor = 0,68. O nervo musculocutâneo foi significativamente mais fácil de bloquear com o estimulador de nervo periférico (p = 0,034. CONCLUSÕES: A técnica de múltipla estimulação para o bloqueio axilar usando estimulador de nervos (3 injeções e a técnica transarterial (2 injeções produzem resultados semelhantes na qualidade do bloqueio. O nervo musculocutâneo é mais facilmente bloqueado com o uso do estimulador de nervo periférico. A técnica de múltipla estimulação necessitou menor suplementação do bloqueio e aumentou o tempo para o início da cirurgia.JUSTIFICATIVA Y OBJETIVOS: La técnica transarterial con grandes dosis de anestésico local

  10. Sealing of Gastrointestinal Anastomoses with a Fibrin Glue-Coated Collagen Patch: A Safety Study

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Rømer, John; Sørensen, Michael

    2007-01-01

    gastrointestinal anastomoses with a collagen patch coated with fibrin glue. The study is a prospective, experimental animal study comparing sealed and unsealed gastrointestinal anastomoses. Laparotomy was performed in 11 pigs under general anesthesia. In each pig two anastomoses were performed on the small......Sealing of anastomoses has previously been tested with several methods, including sealing with liquid fibrin glue. Sealing with a collagen patch coated with fibrin glue components has never been systematically examined. The aim of the present study was to determine the safety of sealing...... intestine. One of the anastomoses was sealed with a collagen patch coated with fibrin glue components (TachoSil). The other anastomosis contained no sealing. The pigs were observed for 1 to 6 weeks. The observation period was followed by in vivo examination under general anesthesia and included observation...

  11. Hearing loss in a glue sniffer.

    Science.gov (United States)

    Williams, D M

    1988-10-01

    A case is presented of a 27-year-old glue sniffing woman with sensorineural hearing loss, optic atrophy and global brain damage. This form of addiction has not received much attention as a cause of otologic catastrophes, and should be borne in mind where similar cases come to the otolaryngologist.

  12. Photoclickable dendritic molecular glue: noncovalent-to-covalent photochemical transformation of protein hybrids.

    Science.gov (United States)

    Uchida, Noriyuki; Okuro, Kou; Niitani, Yamato; Ling, Xiao; Ariga, Takayuki; Tomishige, Michio; Aida, Takuzo

    2013-03-27

    A water-soluble dendron with a fluorescein isothiocyanate (FITC) fluorescent label and bearing nine pendant guanidinium ion (Gu(+))/benzophenone (BP) pairs at its periphery (Glue(BP)-FITC) serves as a "photoclickable molecular glue". By multivalent salt-bridge formation between Gu(+) ions and oxyanions, Glue(BP)-FITC temporarily adheres to a kinesin/microtubule hybrid. Upon subsequent exposure to UV light, this noncovalent binding is made permanent via a cross-linking reaction mediated by carbon radicals derived from the photoexcited BP units. This temporal-to-permanent transformation by light occurs quickly and efficiently in this preorganized state, allowing the movements of microtubules on a kinesin-coated glass plate to be photochemically controlled. A fundamental difference between such temporal and permanent bindings was visualized by the use of "optical tweezers".

  13. Hepatocellular carcinoma: the correlation between the enhancement in arterial-phase and lipiodol accumulation after the trans-arterial chemoembotherapy

    International Nuclear Information System (INIS)

    Tan Lilian; Li Yangbing; Li Shuxin; Jiang Jindai; Li Zhimin; Liang Tongjie; Zhou Shaoping; Han Minjun

    2005-01-01

    Objective: To investigate the relationship between enhancement in arterial-phase, indicating arterial blood supply of the lesions of hepatocellular carcinoma and lipiodol accumulation after the trans-arterial chemoembotherapy. Methods: CT images of primary hepatocellular carcinoma in 32 cases during the hepatic arterial-phase were retrospectively compared with the CT images of lipiodol distribution within the tumor after the trans-arterial chemoembotherapy. Results: The lipiodol distribution was classified into five types: homogeneous and compact(n=11), inhomogeneous though compact (n=7), scanty(n=5), poorly filled(n=3) and miscellaneous (n=3). The lipiodol has a homogeneous or inhomogeneous but compact distribution when remarkable enhancement of the tumor or dominant neoplastic vascularity was demonstrated during hepatic arterial-phase. The lipiodol distribution was scanty, poorly filled, or miscellaneous distributed in the nidus of the hepatocellular carcinoma with no or poor enhancement, or with hypo-vascularity during hepatic arterial-phase. Where there was abundant vascularity of the tumor, there would be a satisfying accumulation of the lipiodol. Conclusion: The CT assessmant of the arterial-phase vascularity of the hepatocellular provides valuable information of lipiodol accumulation after the trans-arterial chemoembotherapy. (authors)

  14. Effect of BioGlue on the incidence of pancreatic fistula following pancreas resection.

    Science.gov (United States)

    Fisher, William E; Chai, Christy; Hodges, Sally E; Wu, Meng-Fen; Hilsenbeck, Susan G; Brunicardi, F Charles

    2008-05-01

    Despite numerous modifications of surgical technique, pancreatic fistula remains a serious problem and occurs in about 10% of patients following pancreas resection. BioGlue is a new sealant that creates a flexible mechanical seal within minutes independent of the body's clotting mechanism. Application of BioGlue sealant will reduce the incidence of pancreatic fistula following pancreas resection. A retrospective cohort study was performed with 64 patients undergoing pancreas resection. BioGlue sealant was applied to the pancreatic anastomosis (Whipple) or resection margin (distal pancreatectomy) in 32 cases. Factors that could affect the rate of postoperative pancreatic fistula were recorded. Pancreatic fistula was defined as greater than 50 ml of drain output with an amylase content greater than three times normal serum value after postoperative day 10. To improve the sensitivity of our study, we also examined pancreatic fistula with a strict definition of any drain output on or after postoperative day 3 with a high amylase content and graded the fistulas in terms of clinical severity. Grade A leaks were defined as subclinical. Grade B leaks required some response such as making the patient nil per os, parenteral nutrition, octreotide, antibiotics, or a prolonged hospital stay. Grade C leaks were defined as serious and life threatening. They were associated with hemorrhage, sepsis, resulted in deterioration of other organ systems, and mandated intensive care. Comparisons between the two groups were made using the chi-square test or Fisher's exact test for categorical variables and by the Wilcoxon rank-sum test for continuous variables. P values of 0.05 or less were deemed statistically significant. There were no differences between the patients who received BioGlue and the control cohort in terms of comorbid conditions, tumor location, texture of the pancreas, size of the pancreatic duct, or surgical technique. By the common definition, pancreatic fistula occurred

  15. Optimization of performance parameters for large area silicon photomultipliers for use in the GlueX experiment

    Science.gov (United States)

    Janzen, Kathryn Louise

    Largely because of their resistance to magnetic fields, silicon photomultipliers (SiPMs) are being considered as the readout for the GlueX Barrel Calorimeter, a key component of the GlueX detector located immediately inside a 2.2 T superconducting solenoid. SiPMs with active area 1 x 1 mm2 have been investigated for use in other experiments, but detectors with larger active areas are required for the GlueX BCAL. This puts the GlueX collaboration in the unique position of being pioneers in the use of this frontend detection revolution by driving the technology for larger area sensors. SensL, a photonics research and development company in Ireland, has been collaborating with the University of Regina GlueX group to develop prototype large area SiPMs comprising 16 - 3x3 mm2 cells assembled in a close-packed matrix. Performance parameters of individual SensL 1x1 mm2 and 3x3 mm2 SiPMs along with prototype SensL SiPM arrays are tested, including current versus voltage characteristics, photon detection efficiency, and gain uniformity, in an effort to determine the suitability of these detectors to the GlueX BCAL readout.

  16. Retrospective analysis of surgery and trans-arterial embolization for major non-variceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Griffiths, Ewen A; McDonald, Chris R; Bryant, Robert V; Devitt, Peter G; Bright, Tim; Holloway, Richard H; Thompson, Sarah K

    2016-05-01

    With proton pump inhibitors and current sophisticated endoscopic techniques, the number of patients requiring surgical intervention for upper gastrointestinal bleeding has decreased considerably while trans-arterial embolization is being used more often. There are few direct comparisons between the effectiveness of surgery and embolization. A retrospective study of patients from two Australian teaching hospitals who had surgery or trans-arterial embolization (n = 103) for severe upper gastrointestinal haemorrhage between 2004 and 2012 was carried out. Patient demographics, co-morbidities, disease pathology, length of stay, complications, and overall clinical outcome and mortality were compared. There were 65 men and 38 women. The median age was 70 (range 36-95) years. Patients requiring emergency surgical intervention (n = 79) or trans-arterial embolization (n = 24) were compared. The rate of re-bleeding after embolization (42%) was significantly higher compared with the surgery group (19%) (P = 0.02). The requirement for further intervention (either surgery or embolization) was also higher in the embolization group (33%) compared with the surgery group (13%) (P = 0.03). There was no statistical difference in mortality between the embolization group (5/24, 20.8%) and the surgical group (13/79, 16.5%) (P = 0.75). Emergency surgery and embolization are required in 2.6% of patients with upper gastrointestinal bleeding. Both techniques have high mortalities reflecting the age, co-morbidities and severity of bleeding in this patient group. © 2014 Royal Australasian College of Surgeons.

  17. Improving the results of transarterial embolization of type 2 endoleaks with the embolic polymer Onyx.

    Science.gov (United States)

    Wojtaszek, Mikolaj; Wnuk, Emilia; Maciag, Rafal; Solonynko, Bohdan; Korzeniowski, Krzysztof; Lamparski, Krzysztof; Rowinski, Olgierd

    2016-01-01

    Type 2 endoleaks (T2E) occur in 10 to 20% of patients after endovascular abdominal aortic aneurysm repair (EVAR) and remain a significant clinical issue. To evaluate the efficacy and clinical outcomes of transarterial treatment of persistent type II endoleaks after EVAR using the liquid embolic Onyx. From February 2012 to August 2015 transarterial T2E embolization was attempted in 22 patients (21 men, median age: 73, range: 62-88 years). Indications for treatment included an increase in the diameter of the aneurysm sac above 5 mm and a persistent endoleak observed for more than 6 months. Mean time from EVAR to endoleak treatment was 43 months (range: 2-125 months). Primary technical success was achieved in 17 (77.3%) patients and secondary technical success in 81.8%, with 0% in-hospital mortality. The mean procedure time was 95 ±48 min, with an average fluoroscopy time of 54 ±25 min. The mean amount of Onyx used was 7.5 ±6.6 ml. Clinical success was seen in 17/21 patients with follow-up imaging (80.9%). Mean follow-up time was 17 months (range: 3-38 months). Onyx has been shown to effectively stabilize previous aneurysm growth as a result of the T2E in the majority of our patients. Transarterial embolization of T2E can be significantly improved as compared to previously reported results by using liquid embolic polymers such as Onyx.

  18. High-Flow Vascular Malformation in the Sigmoid Mesentery Successfully Treated with a Combination of Transarterial and Transvenous Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Kamo, Minobu, E-mail: kamomino@luke.ac.jp; Yagihashi, Kunihiro [St. Luke’s International Hospital, Department of Radiology (Japan); Okamoto, Takeshi; Nakamura, Kenji; Fujita, Yoshiyuki [St. Luke’s International Hospital, Department of Gastroenterology (Japan); Kurihara, Yasuyuki [St. Luke’s International Hospital, Department of Radiology (Japan)

    2016-12-15

    Mesenteric high-flow vascular malformation can cause various clinical symptoms and demand specific therapeutic interventions owing to its peculiar hemodynamics. We report a case of high-flow vascular malformation in the sigmoid mesentery which presented with ischemic colitis. The main trunk of the inferior mesenteric vein was occluded. After partially effective transarterial embolization, transvenous embolization was performed using a microballoon catheter advanced to the venous component of the lesion via the marginal vein. Complete occlusion of the lesion was achieved. Combination of transarterial and transvenous embolization may allow us to apply endovascular treatment to a wider variety of high-flow lesions in the area and possibly avoid the bowel resection.

  19. [Chemical hazards when working with solvent glues].

    Science.gov (United States)

    Domański, Wojciech; Makles, Zbigniew

    2012-01-01

    Solvent glues are used in a wide variety of industries, e.g., textile, footwear and rubber. The problem of workers' exposure to solvent vapors is rarely tackled within the area of occupational safety and health in small and medium-sized enterprises. In order to assess exposure to solvents, organic solvents emitted by glues were identified in the samples of workplace air. The concentration of acetone, benzene, cyclohexane, ethylbenzene, n-hexane, methylcyclohexane, butyl acetate and toluene were determined. The obtained results evidenced the presence of cyclohexane, ethylbenzene, ethylcyclohexane, heptane, n-hexane, o-xylene, methylcyclohexane, methylcyclopentane, butyl acetate and toluene in workplace air. The concentration of those compounds in workplace air was low, usually below 0.15 of MAC. At some workstations the presence of benzene was also observed. Occupational risk was assessed at workstations where gluing took place. It showed that the risk at those workstations was medium or low.

  20. Transarterial ablation of hepatocellular carcinoma. Status and developments

    International Nuclear Information System (INIS)

    Radeleff, B.A.; Stampfl, U.; Sommer, C.M.; Bellemann, N.; Kauczor, H.U.; Hoffmann, K.; Ganten, T.; Ehehalt, R.

    2012-01-01

    Hepatocellular carcinoma (HCC) is the fifth most common cancer worldwide and represents the main cause of death among European patients with liver cirrhosis. Only 30-40% of patients diagnosed with HCC are candidates for curative treatment options (e.g. surgical resection, liver transplantation or ablation). The remaining majority of patients must undergo local regional and palliative therapies. Transvascular ablation of HCC takes advantage of the fact that the hypervascularized HCC receives most of its blood supply from the hepatic artery. In this context transvascular ablation describes different therapy regimens which can be assigned to four groups: cTACE (conventional transarterial chemoembolization), bland embolization (transarterial embolization TAE), DEB-TACE (TACE with drug-eluting beads, DEB) and SIRT (selective internal radiation therapy, radioembolization). Conventional TACE is the most common type of transvascular ablation and represents a combination of intra-arterial chemotherapy and embolization with occlusion of the arterial blood supply. However, there is no standardized regimen with respect to the chemotherapeutic drug, the embolic agent, the usage of lipiodol and the interval between the TACE procedures. Even the exact course of a cTACE procedure (order of chemotherapy or embolization) is not standardized. It remains unclear whether or not intra-arterial chemotherapy is definitely required as bland embolization using very small, tightly calibrated spherical particles (without intra-arterial administration of a chemotherapeutic drug) shows tumor necrosis comparable to cTACE. For DEB-TACE microparticles loaded with a chemotherapeutic drug combine the advantages of cTACE and bland embolization. Thereby, a continuing chemotherapeutic effect within the tumor might cause a further increase in intratumoral cytotoxicity and at the same time a decrease in systemic toxicity. (orig.) [de

  1. Sediment Curve Uncertainty Estimation Using GLUE and Bootstrap Methods

    Directory of Open Access Journals (Sweden)

    aboalhasan fathabadi

    2017-02-01

    Full Text Available Introduction: In order to implement watershed practices to decrease soil erosion effects it needs to estimate output sediment of watershed. Sediment rating curve is used as the most conventional tool to estimate sediment. Regarding to sampling errors and short data, there are some uncertainties in estimating sediment using sediment curve. In this research, bootstrap and the Generalized Likelihood Uncertainty Estimation (GLUE resampling techniques were used to calculate suspended sediment loads by using sediment rating curves. Materials and Methods: The total drainage area of the Sefidrood watershed is about 560000 km2. In this study uncertainty in suspended sediment rating curves was estimated in four stations including Motorkhane, Miyane Tonel Shomare 7, Stor and Glinak constructed on Ayghdamosh, Ghrangho, GHezelOzan and Shahrod rivers, respectively. Data were randomly divided into a training data set (80 percent and a test set (20 percent by Latin hypercube random sampling.Different suspended sediment rating curves equations were fitted to log-transformed values of sediment concentration and discharge and the best fit models were selected based on the lowest root mean square error (RMSE and the highest correlation of coefficient (R2. In the GLUE methodology, different parameter sets were sampled randomly from priori probability distribution. For each station using sampled parameter sets and selected suspended sediment rating curves equation suspended sediment concentration values were estimated several times (100000 to 400000 times. With respect to likelihood function and certain subjective threshold, parameter sets were divided into behavioral and non-behavioral parameter sets. Finally using behavioral parameter sets the 95% confidence intervals for suspended sediment concentration due to parameter uncertainty were estimated. In bootstrap methodology observed suspended sediment and discharge vectors were resampled with replacement B (set to

  2. The Effect of Seaweed Glue in the Separation of Copper–Molybdenum Sulphide Ore by Flotation

    Directory of Open Access Journals (Sweden)

    Zhixiang Chen

    2018-01-01

    Full Text Available Flotation separation of chalcopyrite from molybdenite was studied using seaweed glue (SEG as a depressant. Flotation process and mechanism were examined by response surface methodology, flotation tests, adsorption tests, zeta potential measurements and fourier transform infrared (FT-IR spectra. Response surface methodology with a Box–Behnken design suggested the optimal reagent schedule: pH 4, depressant seaweed glue 197 mg/L, collector amyl xanthate 16 mg/L and frother (methyl isobutyl carbinol 20 mg/L, and selective separation of chalcopyrite and molybdenite was achieved by flotation. Comparison of SEG and traditional depressants indicated that the SEG could achieve a similar separation efficiency, and exhibited the advantages of environmental compatibility and economic adaptability. Co-adsorption of seaweed glue and amyl xanthate occurred on the surface of molybdenite, and is explained to happen through distinct mechanisms due to the heterogeneous nature of the surface. It is likely that seaweed glue depresses molybdenite by covering the dixanthogen resulting from adsorption of xanthate ions. It is shown that seaweed glue is as effective a depressant of Cu/Mo separation as cyanide.

  3. Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate.

    Science.gov (United States)

    Nakayama, Y; Matsuda, T

    1999-01-01

    This article presents a novel photochemically driven surgical tissue adhesive technology using photoreactive gelatins and a water-soluble difunctional macromer (poly(ethylene glycol) diacrylate: PEGDA).The gelatins were partially derivatized with photoreactive groups, such as ultraviolet light (UV)-reactive benzophenone and visible light-reactive xanthene dye (e.g., fluorescein sodium salt, eosin Y, and rose bengal). A series of the prepared photocurable tissue adhesive glues, consisting of the photoreactive gelatin, PEGDA, and a saline solution with or without ascorbic acid as a reducing agent, were viscous solutions under warming, and their effectiveness was evaluated as hemostasis- and anastomosis-aid in cardiovascular surgery. Regardless of the type of photoreactive groups, the irradiation of the photocurable tissue adhesive glues by UV or visible light within 1 min produced water-swollen gels, which had a high adhesive strength to wet collagen film. These were due to the synergistic action of photoreactive group-initiated photo-cross-linking and photograft polymerization. An increase in the irradiation time resulted in increased gel yield and reduced water swellability. A decrease in the molecular weight of PEGDA and an increase in concentration of both gelatin and PEGDA resulted in reduced water swellability and increased tensile and burst strengths of the resultant gels. In rats whose livers were injured with a trephine in laparotomy, the bleeding spots were coated with the photocurable adhesive glue and irradiated through an optical fiber. The coated solution was immediately converted to a swollen gel. The gel was tightly adhered to the liver tissue presumably by interpenetration, and concomitantly hemostasis was completed. The anastomosis treatment with the photocurable glue in the canine abdominal or thoracic aortas incised with a knife resulted in little bleeding under pulsatile flow after declamping. Histological examination showed that the glues

  4. Preoperative trans-arterial embolization for spinal tumor: embolization techniques and results

    International Nuclear Information System (INIS)

    Shi Haibin; Xu Daizhe

    2000-01-01

    Objective: To analyze the technique and to evaluate the safety and value of preoperative trans-arterial embolization of hypervascular spinal tumors. Methods: Eighteen patients with hypervascular spinal tumors underwent trans-arterial embolization before surgery. They arose intradural in six patients and extradural in 12. Thirty-one arteries were embolized with polyvinyl alcohol (PVA) particles (150-500 μm), of which 18 with additional pieces of gelatin sponge for proximal pedicular embolization. The criteria for judging the effectiveness of embolization were the completeness of tumor removal and estimated blood loss during surgery. Results: Tumor embolization with total occlusion was obtained in eight patients, second to total in seven, subtotal in one, and partial in two. There were no symptomatic complications associated with embolization. Tumors were totally removed in 17 patients and nearly totally removed in one. The average estimated blood loss during surgery was 1100 ml (range, 200-6000 ml) for all 18 patients, and 1540 ml in patients with extradural tumors. Conclusions: Preoperative embolization of hypervascular spinal tumors is safe and effective. It can make complete resection of a tumor possible and can make an unresectable tumor resectable. Superselection or flow control is necessary to achieve effective devascularization and avoid complications

  5. Magnetic Retraction of Bowel by Intraluminal Injectable Cyanoacrylate-Based Magnetic Glue

    Directory of Open Access Journals (Sweden)

    Zhigang Wang

    2013-01-01

    Full Text Available Magnetic retraction offers advantages over physical retraction by graspers because of reduced tissue trauma. The objectives of this study are to investigate a novel method of magnetisation of bowel segments by intraluminal injection of magnetic glue and to demonstrate the feasibility of magnetic retraction of bowel with sufficient force during minimal access surgery. Following an initial materials characterisation study, selected microparticles of stainless steel (SS410-μPs were mixed with chosen cyanoacrylate glue (Loctite 4014. During intraluminal injection of the magnetic glue using ex vivo porcine colonic segments, a magnetic probe placed at the injected site ensured that the SS410-μPs aggregated during glue polymerisation to form an intraluminal mucosally adherent coagulum. The magnetised colonic segments were retracted by magnetic probes (5 and 10 mm placed external to the bowel wall. A tensiometer was used to record the retraction force. With an injected volume of 2 mL in a particle concentration of 1 g/mL, this technique produced maximal magnetic retraction forces of 2.24 ± 0.23 N and 5.11 ± 0.34 N (, with use of 5 and 10 mm probes, respectively. The results indicate that the formation of an intraluminal coagulum based on SS410-μPs and Loctite 4014 produces sufficient magnetic retraction for bowel retraction.

  6. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    Science.gov (United States)

    Poley, L.; Bloch, I.; Edwards, S.; Friedrich, C.; Gregor, I.-M.; Jones, T.; Lacker, H.; Pyatt, S.; Rehnisch, L.; Sperlich, D.; Wilson, J.

    2016-05-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  7. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    International Nuclear Information System (INIS)

    Poley, L.; Bloch, I.; Friedrich, C.; Gregor, I.-M.; Edwards, S.; Pyatt, S.; Wilson, J.; Jones, T.; Lacker, H.; Rehnisch, L.; Sperlich, D.

    2016-01-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  8. Linkage and mapping analyses of the no glue egg gene Ng in the ...

    African Journals Online (AJOL)

    In the silkworm, Bombyx mori, no glue egg is mainly controlled by Ng (No glue) gene, which is located on the 12th chromosome. Owning to a lack of crossing over in females, reciprocal backcrossed F1 (BC1) progenies were used for linkage analysis and mapping of the Ng gene based on the simple sequence repeats ...

  9. Nuovi Metodi di visualizzazione geografica: l'approccio Focus+Glue+Context

    Directory of Open Access Journals (Sweden)

    Flavio Lupia

    2010-03-01

    Full Text Available New cartographic visualization methods: the Focus+Glue+Context approach Focus+Glue+Context is a new cartographic visualization method specifically designed to solve the fruition problems connected with the use of mobile devices and web mapping services. The objective of the F+G+C approach is to reduce users cognitive efforts when reading a map: to do so, the area of interest is ‘highlighted’ in a lower and more detailed scale through a fisheye lens effect, while the sorrouding context, useful to the user to determine the items relationships in a map, is maintained on a higher scale.

  10. Nuovi Metodi di visualizzazione geografica: l'approccio Focus+Glue+Context

    Directory of Open Access Journals (Sweden)

    Flavio Lupia

    2010-03-01

    Full Text Available New cartographic visualization methods:the Focus+Glue+Context approachFocus+Glue+Context is a new cartographic visualization method specifically designed to solve the fruition problems connected with the use of mobile devices and web mapping services. The objective of the F+G+C approach is to reduce users cognitive efforts when reading a map: to do so, the area of interest is ‘highlighted’ in a lower and more detailed scale through a fisheye lens effect, while the sorrouding context, useful to the user to determine the items relationships in a map, is maintained on a higher scale.

  11. SHEAR STRENGTH IN THE GLUE LINE OF Eucalyptus sp. AND Pinus sp.WOOD

    Directory of Open Access Journals (Sweden)

    Juliana Jerásio Bianche

    Full Text Available ABSTRACT To evaluate the adhesive efficiency on the union of glued joints in a particular temperature and humidity conditions for a specified time the adhesive must be submitted to specific load tests, such as shear in the glue line. The objective of this study was to evaluate the shear strength in the glue line of Eucalyptus sp and Pinus sp.woods. Five adhesives (castor oil, sodium silicate, modified silicate, , PVA and resorcinol-formaldehyde, three weights (150 g/m2, 200 g/m2, and 250 g/m2 and two species (Eucalyptus sp. and Pinus sp. of wood were used. Twelve specimens were obtained from each repetition per treatment, corresponding to 108 specimens that were conditioned at a temperature of 23 ± 1°C and relative humidity of 50 ± 2%. The interaction between the weight and type of adhesive was significant for the shear strength in the glue line of eucalyptus wood. However, no interaction between the weight and the adhesive was found for pinus, only the isolated from the adhesive effect. Chemical bonds originated in the polymerization of resorcinol-formaldehyde adhesives and castor bi-component conferred upon these adhesives the greatest resistance in the glue line. Castor and resorcinol-formaldehyde adhesives showed the highest shear strength values in the line of glue and wood failure. Castor adhesive presented satisfactory performance for bonding of eucalyptus and pine woods.

  12. Ruptured Aortic Aneurysm From Late Type II Endoleak Treated by Transarterial Embolization

    International Nuclear Information System (INIS)

    Gunasekaran, Senthil; Funaki, Brian; Lorenz, Jonathan

    2013-01-01

    Endoleak is the most common complication after endovascular aneurysm repair. The most common type of endoleak, a type II endoleak, typically follows a benign course and is only treated when associated with increasing aneurysm size. In this case report, we describe a ruptured abdominal aortic aneurysm due to a late, type II endoleak occurring 10 years after endovascular aneurysm repair that was successfully treated by transarterial embolization.

  13. Science to Practice: Killing Dormant Cells-Is Targeting Autophagy the Key to Complete Tumor Response in Transarterial Chemoembolization?

    Science.gov (United States)

    Savic, Lynn Jeanette; Chapiro, Julius; Geschwind, Jean-François

    2017-06-01

    In this issue of Radiology, Gade et al ( 1 ) describe a unique mechanism of hepatocellular carcinoma (HCC) cells for surviving ischemia induced by transarterial embolization (TAE)/transarterial chemoembolization (TACE) in a state of cell cycle arrest-a function that may serve as a defensive shield against conventional chemotherapeutic agents. This finding adds to our knowledge and establishes a previously poorly understood mechanism of chemoresistance in HCC. As the Achilles heel in terms of this process, a concurrent upregulation of autophagic flux as an adaptive response to TAE-like ischemia was found by the authors. This is a targetable mechanism that can potentially be exploited for combined therapeutic approaches of embolotherapy and autophagy inhibition in HCC.

  14. BioGlue iceball stabilization to minimize the risk of hemorrhage during laparoscopic renal cryoablation.

    Science.gov (United States)

    Mues, Adam C; Graversen, Joseph A; Truesdale, Matthew D; Casazza, Cristin; Landman, Jaime

    2011-08-01

    To evaluate the application of a BioGlue adhesive shell to minimize iceball fracture. Iceball fracture and hemorrhage is common with laparoscopic cryoablation (LCA) of larger (>4 cm) renal tumors. Twenty large iceballs were created in porcine kidneys using 3 cryoablation probes in a nonsurvival study. Each kidney underwent an upper and lower pole ablation. One pole in each kidney was covered with 5 mL of BioGlue and the opposite pole served as a control. A double freeze-thaw cycle was performed (10 minutes freeze and 5 minutes active thaw) in both renal poles simultaneously. The probes were removed and the sites were monitored for 20 minutes under direct vision. Fracture length (mm), severity of fracture depth, severity of bleeding (absent, mild, moderate, severe), and estimated blood loss (EBL) (mL) were recorded. In the control group, the mean fracture length was 1.9 mm (range, 0-3 mm). Blood loss was absent in 10%, mild in 60%, and moderate in 30% of ablations. The mean EBL was 20.5 mL (range, 0-50 mL). For the BioGlue ablations, there were no parenchymal fractures. Blood loss was mild in 30% and absent in 70% of sites with an average EBL of 5 mL (range, 0-20). Two bleeding sites occurred as a result of subcapsular hematomas caused by initial probe placement. BioGlue application minimized the frequency and magnitude of renal fracture. EBL was lower with BioGlue application and most sites demonstrated no postablation bleeding. Further clinical study of the BioGlue shell should be performed to confirm these results. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Transarterial embolization for the treatment of massive bleeding in gynecologic and obstetric emergencies: a single center experience.

    Science.gov (United States)

    Hongsakul, Keerati; Songjamrat, Apiradee; Rookkapan, Sorracha

    2014-08-01

    Delayed treatment of the massive bleeding in gynecologic and obstetric conditions can cause high morbidity and mortality. The aim of this study is to assess the angiographic findings and outcomes of transarterial embolization in cases of massive hemorrhage from underlying gynecological and obstetrical conditions. This is a retrospective study of 18 consecutive patients who underwent transarterial embolization of uterine and/or hypogastric arteries due to massive bleeding from gynecological and obstetrical causes from January 2006 to December 2011. The underlying causes of bleeding, angiographic findings, technical success rates, clinical success rates, and complications were evaluated. Massive gynecological and obstetrical bleeding occurred in 12 cases and 6 cases, respectively. Gestational trophoblastic disease was the most common cause of gynecological bleeding. The most common cause of obstetrical hemorrhage was primary post-partum hemorrhage. Tumor stain was the most frequent angiographic finding (11 cases) in the gynecological bleeding group. The most common angiographic findings in obstetrical patients were extravasation (2 cases) and pseudoaneurysm (2 cases). Technical and final clinical success rates were found in all 18 cases and 16 cases. Collateral arterial supply, severe metritis, and unidentified cervical laceration were causes of uncontrolled bleeding. Only minor complications occurred, which included pelvic pain and groin hematoma. Percutaneous transarterial embolization is a highly effective and safe treatment to control massive bleeding in gynecologic and obstetric emergencies.

  16. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  17. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs

    Directory of Open Access Journals (Sweden)

    Đenić Nebojša

    2015-01-01

    Full Text Available Background/Aim. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding next 4 to 7 days. The aim of this study was to create the preconditions for gunshot wounds closing without complications by the application of fibrin glue with antibiotics 24 h after primary surgical treatment. Methods. A total of 14 pigs were wounded in the gluteofemoral region by the bullet M67, initial velocity of 720 m/s. All wounded animals were surgically treated according to the principles of the warsurgery doctrine. Seven wounds were closed with primary delayed suture four days after the primary surgical treatment (traditional approach. Fibrin glue with antibiotics was introduced in seven wounds during the primary surgical treatment and primary delayed suture was done after 24 h. The macroscopic appearance and the clinical assessment of the wound were done during the primary surgical treatment and during its revision after 24 h, as well as histopathological findings at the days 4 and 7 after wounding. Results. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47 7.62 mm, and treated with fibrin glue with antibiotics after primary surgical management, were closed with primary delayed suture after 24 h. In further wound evolution there were no complications. Conclusion. Uncomplicated soft-tissue wounds caused by an automatic M70AB2 rifle may be closed primarily with delayed suture without the risk of developing complications if on revision, 24 h after primary surgery, there were no present necrotic tissues, hematoma, and any signs of infection when fibrin glue with antibiotics

  18. Bandwidth-Tunable Fiber Bragg Gratings Based on UV Glue Technique

    Science.gov (United States)

    Fu, Ming-Yue; Liu, Wen-Feng; Chen, Hsin-Tsang; Chuang, Chia-Wei; Bor, Sheau-Shong; Tien, Chuen-Lin

    2007-07-01

    In this study, we have demonstrated that a uniform fiber Bragg grating (FBG) can be transformed into a chirped fiber grating by a simple UV glue adhesive technique without shifting the reflection band with respect to the center wavelength of the FBG. The technique is based on the induced strain of an FBG due to the UV glue adhesive force on the fiber surface that causes a grating period variation and an effective index change. This technique can provide a fast and simple method of obtaining the required chirp value of a grating for applications in the dispersion compensators, gain flattening in erbium-doped fiber amplifiers (EDFAs) or optical filters.

  19. [Propolis. The bee glue as presented by the Graeco-Roman literature].

    Science.gov (United States)

    Golder, Werner

    2004-01-01

    The bee glue, commonly known as propolis, has been employed for medical purposes already in teh ancient world. More than 15 Greek and Roman authors report on the preparation and application of the so-called third natural product of the bees (besides honey and wax). Aristoteles described the fundamental issues of its biology in his 'Historia Animalium' correctly. The bulk of propolis is obtained from the barks of poplars. Once carried in the hives, the glue is used to stabilize the cells and honeycombs and to protect the bees against invaders and cold weather. Propolis has been chiefly employed for the preparation of ointment and plasters. For this purpose, the viscous raw material was purified, moulded and boiled. In most preparations, the bee glue was only one of many (up to 20) pharmacologically active constituents and came to five to 20% of the mixture. Only rarely, a single drug therapy was using propolis was carried out. The application of the glue was most successful in general surgery and casualties. In that respect, the ancient physicians took advantage of the anti-edematous and anti-infectious properties of the substance. Thus, it was used to treat bumps, indurations, and slow-healing wounds. Moreover, cataplasms against swollen cervical nodes and indurations of the female breast often contained propolis. Finally, bee glue proved successful for the treatment of chronic backache and pain in the hip as well as fresh injuries of muscles and tendons. In the sector of skin diseases, lichens and condylomata were found to respond well to propolis. ALl this indications have been a matter of several records. However, the successful use of propolis in diseases of the stomach and liver has ben reported solely by Alexander of Tralles (6th century AD). Not counting the internal diseases, the spectrum of indications for propolis has not substantially changed as compared to the classical antiquity. Interestingly, radiation therapists have adopted the ancient remedy and

  20. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs

    OpenAIRE

    Đenić Nebojša; Višnjić Milan; Dragović Saša; Bojanić Vladmila; Bojanić Zoran; Đurđević Dragan; Đinđić Boris; Kostov Miloš

    2015-01-01

    Background/Aim. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47) 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding n...

  1. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS inner detector

    International Nuclear Information System (INIS)

    Poley, Luise; Bloch, Ingo; Edwards, Sam

    2016-04-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives. Results from electrical tests of first prototype modules constructed using these glues are presented.

  2. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS inner detector

    Energy Technology Data Exchange (ETDEWEB)

    Poley, Luise [DESY, Zeuthen (Germany); Humboldt Univ. Berlin (Germany); Bloch, Ingo [DESY, Zeuthen (Germany); Edwards, Sam [Birmingham Univ. (United Kingdom); and others

    2016-04-15

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives. Results from electrical tests of first prototype modules constructed using these glues are presented.

  3. How to Prepare a Patient for Transarterial Radioembolization? A Practical Guide

    Energy Technology Data Exchange (ETDEWEB)

    Denys, Alban, E-mail: Alban.Denys@chuv.ch [Centre Hospitalier Universitaire Vaudois and University of Lausanne, Department of Radiology and Interventional Radiology (Switzerland); Pracht, Marc [Centre Hospitalier Universitaire Vaudois and University of Lausanne, Department of Oncology (Switzerland); Duran, Rafael [John Hopkins University, Department of Interventional Radiology (United States); Guiu, Boris [Centre Hospitalier Universitaire Vaudois and University of Lausanne, Department of Radiology and Interventional Radiology (Switzerland); Adib, Salim; Boubaker, Ariane [Centre Hospitalier Universitaire Vaudois and University of Lausanne, Department of Nuclear Medicine (Switzerland); Bize, Pierre [Centre Hospitalier Universitaire Vaudois and University of Lausanne, Department of Radiology and Interventional Radiology (Switzerland)

    2015-08-15

    Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.

  4. How to Prepare a Patient for Transarterial Radioembolization? A Practical Guide.

    Science.gov (United States)

    Denys, Alban; Pracht, Marc; Duran, Rafael; Guiu, Boris; Adib, Salim; Boubaker, Ariane; Bize, Pierre

    2015-08-01

    Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.

  5. Fibrinogen and thrombin concentrations are critical for fibrin glue adherence in rat high-risk colon anastomoses

    Directory of Open Access Journals (Sweden)

    Eliseo Portilla-de Buen

    2014-04-01

    Full Text Available OBJECTIVE: Fibrin glues have not been consistently successful in preventing the dehiscence of high-risk colonic anastomoses. Fibrinogen and thrombin concentrations in glues determine their ability to function as sealants, healers, and/or adhesives. The objective of the current study was to compare the effects of different concentrations of fibrinogen and thrombin on bursting pressure, leaks, dehiscence, and morphology of high-risk ischemic colonic anastomoses using fibrin glue in rats. METHODS: Colonic anastomoses in adult female Sprague-Dawley rats (weight, 250-350 g treated with fibrin glue containing different concentrations of fibrinogen and thrombin were evaluated at post-operative day 5. The interventions were low-risk (normal or high-risk (ischemic end-to-end colonic anastomoses using polypropylene sutures and topical application of fibrinogen at high (120 mg/mL or low (40 mg/mL concentrations and thrombin at high (1000 IU/mL or low (500 IU/mL concentrations. RESULTS: Ischemia alone, anastomosis alone, or both together reduced the bursting pressure. Glues containing a low fibrinogen concentration improved this parameter in all cases. High thrombin in combination with low fibrinogen also improved adherence exclusively in low-risk anastomoses. No differences were detected with respect to macroscopic parameters, histopathology, or hydroxyproline content at 5 days post-anastomosis. CONCLUSIONS: Fibrin glue with a low fibrinogen content normalizes the bursting pressure of high-risk ischemic left-colon anastomoses in rats at day 5 after surgery.

  6. Use of tissue glue for punch grafting in vitiligo - A preliminary report

    Directory of Open Access Journals (Sweden)

    Ghorpade Ashok

    2004-05-01

    Full Text Available BACKGROUND: Minipunch grafting has been successfully used for the treatment of stable vitiligo since several years. Post-operative immobilization at certain sites such as lips, areola & infralabial folds and joints is not easy to achieve. Putting stay sutures on the lips and areolae is difficult. Grafting over the joints may require hospitalization to ensure proper immobilization, and may discourage some patients. AIM: To study the efficacy of a tissue glue for immobilization of donor grafts at the above sites during minipunch grafting. METHODS: Ten cases with stable vitiligo over the lips, areolae, below the lower lip, and over different joints had tissue glue applied to the edges between the donor grafts and the recipient wells, after the grafting. RESULTS: The grafts adhered firmly within a minute and there was no need for a cumbersome dressing. Over the lips, the patients could resume talking and drinking fluids immediately. CONCLUSION: The glue was very helpful for immobilizing the grafts at these difficult sites.

  7. Transarterial RAdioembolization versus ChemoEmbolization for the treatment of hepatocellular carcinoma (TRACE: study protocol for a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Seinstra Beatrijs A

    2012-08-01

    Full Text Available Abstract Background Hepatocellular carcinoma is a primary malignant tumor of the liver that accounts for an important health problem worldwide. Only 10 to 15% of hepatocellular carcinoma patients are suitable candidates for treatment with curative intent, such as hepatic resection and liver transplantation. A majority of patients have locally advanced, liver restricted disease (Barcelona Clinic Liver Cancer (BCLC staging system intermediate stage. Transarterial loco regional treatment modalities offer palliative treatment options for these patients; transarterial chemoembolization (TACE is the current standard treatment. During TACE, a catheter is advanced into the branches of the hepatic artery supplying the tumor, and a combination of embolic material and chemotherapeutics is delivered through the catheter directly into the tumor. Yttrium-90 radioembolization (90Y-RE involves the transarterial administration of minimally embolic microspheres loaded with Yttrium-90, a β-emitting isotope, delivering selective internal radiation to the tumor. 90Y-RE is increasingly used in clinical practice for treatment of intermediate stage hepatocellular carcinoma, but its efficacy has never been prospectively compared to that of the standard treatment (TACE. In this study, we describe the protocol of a multicenter randomized controlled trial aimed at comparing the effectiveness of TACE and 90Y-RE for treatment of patients with unresectable (BCLC intermediate stage hepatocellular carcinoma. Methods/design In this pragmatic randomized controlled trial, 140 patients with unresectable (BCLC intermediate stage hepatocellular carcinoma, with Eastern Cooperative Oncology Group performance status 0 to 1 and Child-Pugh A to B will be randomly assigned to either 90Y-RE or TACE with drug eluting beads. Patients assigned to 90Y-RE will first receive a diagnostic angiography, followed by the actual transarterial treatment, which can be divided into two sessions in case

  8. Photoproduction of the Cascade Baryons at GlueX

    Science.gov (United States)

    Ernst, Ashley; GlueX Collaboration

    2017-09-01

    Multi-strange baryons play an important role in understanding the strong interaction and despite their importance, little is known about such hyperons. Almost all knowledge of the Cascades today stems from Kaon-nucleon interactions in bubble chamber experiments performed in the 1960s and 1970s, of which only the octet and decuplet ground states, Ξ (1320) and Ξ (1530) respectively, are well established. This research uses the GlueX experiment at Jefferson Laboratory to map out the spectrum of doubly-strange Cascade resonances, as well as to measure the spin-parity for each of the detected resonances. The first physics run for GlueX has recently been completed and a clear signature of the Ξ (1320) is observed. The systematics of the Cascade spectrum will be presented motivated by prior discoveries in the N* program. This work was supported by the U.S. Department of Energy Grant DE-FG02-92ER40735 and National Science Foundation Grant 1449440.

  9. Quality of Life in Hepatocellular Carcinoma Patients Treated with Transarterial Chemoembolization

    Directory of Open Access Journals (Sweden)

    Saleem Ahmed

    2016-01-01

    Full Text Available Hepatocellular carcinoma (HCC is one of the most commonly diagnosed cancers worldwide. Majority of patients with HCC are diagnosed in the advanced stages of disease and hence they are only suitable for palliative therapy. TACE (transarterial chemoembolization is the most commonly used treatment for unresectable HCC. It is however unclear if TACE improves the quality of life (QoL in patients with HCC. The aim of this review is to evaluate the impact of TACE on QoL of HCC patients.

  10. Cross-linking by protein oxidation in the rapidly setting gel-based glues of slugs

    Science.gov (United States)

    Bradshaw, Andrew; Salt, Michael; Bell, Ashley; Zeitler, Matt; Litra, Noelle; Smith, Andrew M.

    2011-01-01

    SUMMARY The terrestrial slug Arion subfuscus secretes a glue that is a dilute gel with remarkable adhesive and cohesive strength. The function of this glue depends on metals, raising the possibility that metal-catalyzed oxidation plays a role. The extent and time course of protein oxidation was measured by immunoblotting to detect the resulting carbonyl groups. Several proteins, particularly one with a relative molecular mass (Mr) of 165×103, were heavily oxidized. Of the proteins known to distinguish the glue from non-adhesive mucus, only specific size variants were oxidized. The oxidation appears to occur within the first few seconds of secretion. Although carbonyls were detected by 2,4-dinitrophenylhydrazine (DNPH) in denatured proteins, they were not easily detected in the native state. The presence of reversible cross-links derived from carbonyls was tested for by treatment with sodium borohydride, which would reduce uncross-linked carbonyls to alcohols, but stabilize imine bonds formed by carbonyls and thus lead to less soluble complexes. Consistent with imine bond formation, sodium borohydride led to a 20–35% decrease in the amount of soluble protein with a Mr of 40–165 (×103) without changing the carbonyl content per protein. In contrast, the nucleophile hydroxylamine, which would competitively disrupt imine bonds, increased protein solubility in the glue. Finally, the primary amine groups on a protein with a Mr of 15×103 were not accessible to acid anhydrides. The results suggest that cross-links between aldehydes and primary amines contribute to the cohesive strength of the glue. PMID:21525316

  11. GLUE 2 deployment: Ensuring quality in the EGI/WLCG information system

    International Nuclear Information System (INIS)

    Burke, Stephen; Pradillo, Maria Alandes; Field, Laurence; Keeble, Oliver

    2014-01-01

    The GLUE 2 information model is now fully supported in the production EGI/WLCG information system. However, to make it usable and allow clients to rely on the published information it is important that the meaning is clearly defined, and that information providers and site configurations are validated to ensure as far as possible that what they publish is correct. In this paper we describe the definition of a detailed schema usage profile, the implementation of a software tool to validate published information according to the profile and the use of the tool in the production Grid, and also summarise the overall state of GLUE 2 deployment.

  12. The establishment of implanted VX2 liver tumor model in rabbits and discussion on superselective left hepatic arterial catheterization with micro-catheter technique via femoral artery

    International Nuclear Information System (INIS)

    Jiang Xiongying; Luo Rongguang; Huang Jinhua; Miao Bijian; Wang Yan

    2011-01-01

    Objective: To establish the implanted VX2 liver tumor model in rabbits and to discuss the feasibility and technical features of superselective left hepatic arterial catheterization by using micro-catheter through the femoral artery catheter sheath. Methods: Forty New Zealand white rabbits were inoculated with fragments of VX2 tumor into the medial left lobe of liver by using a 16G lumbar puncture needle through laparotomy route. Two weeks later, all the rabbits were proved to be successfully inoculated with liver neoplasm on CT scanning. Then, the catheter sheath was inserted into one of the femoral arteries, which was followed by celiac artery angiography and left hepatic artery catheterization with a micro-catheter under DSA guidance in order to evaluate the main branches of celiac artery and the imaging manifestations of VX2 liver tumor. After that, some scheduled interventional experiments were carried out. Results: Imaging examination and histopathologic study showed that the successful rate of implanted rabbit VX2 liver tumor was 100% (40/40). And the successful rate of the catheter sheath inserted to femoral artery was 97.5% (39/40). The successful rate of celiac artery, gastro-hepatic artery, common hepatic artery, proper hepatic artery and left hepatic artery catheterizations was 100% (39/39), 100% (39/39), 100% (39/39), 94.9% (37/39) and 71.2% (28/39) respectively. Conclusion: To implant tumor tissue mass through laparotomy is a stable and reliable method to establish rabbit VX2 liver tumor model. The insertion of micro-catheter through rabbit femoral catheter sheath approach is a convenient and simple technique to be carried out for the left hepatic artery catheterization and it can efficiently solve the technical difficulties when performing the interventional treatment of the rabbit VX2 hepatic tumor via left hepatic artery approach. (authors)

  13. Local Recurrence of Hepatocellular Carcinoma after Segmental Transarterial Chemoembolization: Risk Estimates Based on Multiple Prognostic Factors

    International Nuclear Information System (INIS)

    Park, Seung Hyun; Cho, Yun Ku; Ahn, Yong Sik; Park, Yoon Ok; Kim, Jae Kyun; Chung, Jin Wook

    2007-01-01

    To determine the prognostic factors for local recurrence of nodular hepatocellular carcinoma after segmental transarterial chemoembolization. Seventy-four nodular hepatocellular carcinoma tumors ≤5 cm were retrospectively analyzed for local recurrence after segmental transarterial chemoembolization using follow-up CT images (median follow-up of 17 months, 4 77 months in range). The tumors were divided into four groups (IA, IB, IIA, and IIB) according to whether the one-month follow-up CT imaging, after segmental transarterial chemoembolization, showed homogeneous (Group I) or inhomogeneous (Group II) iodized oil accumulation, or whether the tumors were located within the liver segment (Group A) or in a segmental border zone (Group B). Comparison of tumor characteristics between Group IA and the other three groups was performed using the chi-square test. Local recurrence rates were compared among the groups using the Kaplan-Meier estimation and log rank test. Local tumor recurrence occurred in 19 hepatocellular carcinoma tumors (25.7%). There were: 28, 18, 17, and 11 tumors in Group IA, IB, IIA, and IIB, respectively. One of 28 (3.6%) tumors in Group IA, and 18 of 46 (39.1%) tumors in the other three groups showed local recurrence. Comparisons between Group IA and the other three groups showed that the tumor characteristics were similar. One-, two-, and three-year estimated local recurrence rates in Group IA were 0%, 11.1%, and 11.1%, respectively. The difference between Group IA and the other three groups was statistically significant (p 0.000). An acceptably low rate of local recurrence was observed for small or intermediate nodular tumors located within the liver segment with homogeneous iodized oil accumulation

  14. Physicochemical and functional properties, microstructure, and storage stability of whey protein/polyvinylpyrrolidone based glue sticks

    Directory of Open Access Journals (Sweden)

    Guorong Wang

    2012-11-01

    Full Text Available A glue stick is comprised of solidified adhesive mounted in a lipstick-like push-up tube. Whey is a byproduct of cheese making. Direct disposal of whey can cause environmental pollution. The objective of this study was to use whey protein isolate (WPI as a natural polymer along with polyvinylpyrrolidone (PVP to develop safe glue sticks. Pre-dissolved WPI solution, PVP, sucrose, 1,2-propanediol (PG, sodium stearate, defoamer, and preservative were mixed and dissolved in water at 90 oC and then molded in push-up tubes. Chemical composition, functional properties (bonding strength, glue setting time, gel hardness, extension/retraction, and spreading properties, microstructure, and storage stability of the prototypes were evaluated in comparison with a commercial control. Results showed that all WPI/PVP prototypes had desirable bonding strength and exhibited faster setting than PVP prototypes and control. WPI could reduce gel hardness and form less compact and rougher structures than that of PVP, but there was no difference in bonding strength. PVP and sucrose could increase the hygroscopicity of glue sticks, thus increasing storage stability. Finally, the optimized prototype GS3 (major components: WPI 8.0%, PVP 12.0%, 1,2-propanediol 10.0%, sucrose 10.0%, and stearic sodium 7.0% had a comparable functionality to the commercial control. Results indicated that whey protein could be used as an adhesive polymer for glue stick formulations, which could be used to bond fiber or cellulose derived substrates such as paper.

  15. The limitations and risks of transarterial Onyx injections in the treatment of grade I and II DAVFs

    International Nuclear Information System (INIS)

    Lv Xianli; Jiang Chuhan; Li Youxiang; Liu Lian; Liu Jie; Wu Zhongxue

    2011-01-01

    Background and objective: Embolization of grade III–V intracranial DAVFs using Onyx is feasible with promising results, indicating stability at the time of mid-term follow-up. This article is to evaluate the role of transarterial Onyx embolization in the treatment of grade I and II intracranial dural arteriovenous fistulas (DAVFs), including its limitations and risks. Methods: We retrospectively studied consecutive 26 patients (8 women and 18 men) treated for an grade I and II intracranial DAVF since 2006 in whom a transarterial approach was attempted with Onyx-18 embolization. There were 18 transverse-sigmoid sinus, 4 cavernous sinus, 2 superior sagittal sinus, 1 inferior petrosal sinus and 1 intradiploic fistulas. Five fistulas were Type I, 8 were Type IIa, and 13 were Type IIa + b, according to the Cognard classification. The mean clinical follow-up period was 15.6 months. Results: Anatomic cure was proven in 13 patients (50%) and clinical cure was obtained in 17 cases (65.4%). These 13 cures were achieved after a single procedure. All these 13 patients underwent a follow-up angiography, which has confirmed the complete cure. Partial occlusion was obtained in 13 patients. Complications were as follows: 2 cardiac Onyx migration, 2 reflexive bradyarrythmia, 1 transient visual hallucination, 2 transient fifth nerve palsies and 1 permanent seventh nerve palsy in inferior petrosal sinus DAVF. Conclusions: Based on this experience, grade I and II intracranial DAVFs may be treated with transarterial Onyx embolization to reduce the shunted blood flow and to facilitate subsequent transvenous embolization or surgery.

  16. Transarterial chemoembolization for primary and metastatic liver tumors

    Directory of Open Access Journals (Sweden)

    Popov M.V.

    2016-12-01

    Full Text Available The literature review presents the methodology of transarterial chemoembolization (TACE — widely used method of treatment of primary and secondary liver tumors. The TACE role as a neoadjuvant therapy and the role in the management of unresectable primary and secondary liver tumors are shown. The morphofunctional basis of TACE, benefits of superselective intra-arterial administration of cytostatic agents especially in combination with ischemic impact on a tumor are described. The subject of the choice of the chemotherapeutic agent is also touched; modern drug-loaded microspheres which allow the use of higher doses of the chemotherapeutic drug without increasing systemic effect and prolong its effect on tumor are described. Lack of correlation of presence and severity of a post-embolization syndrome with success of the procedure is noted.

  17. Acute nonlymphocytic leukemia in a glue sniffer.

    Science.gov (United States)

    Caligiuri, M A; Early, A P; Marinello, M J; Preisler, H D

    1985-09-01

    A 17-year-old white male with a past history of chronic inhalational abuse of plastic glue was referred to our institution for sore throat, cervical adenopathy, and an abnormal peripheral blood smear. A diagnosis of acute myelomonocytic leukemia was made and abnormalities in cytogenetic studies were demonstrated. Specific inquiry regarding this form of drug exposure should be pursued when searching for possible etiologies of malignant disease.

  18. Towards GLUE 2: evolution of the computing element information model

    International Nuclear Information System (INIS)

    Andreozzi, S; Burke, S; Field, L; Konya, B

    2008-01-01

    A key advantage of Grid systems is the ability to share heterogeneous resources and services between traditional administrative and organizational domains. This ability enables virtual pools of resources to be created and assigned to groups of users. Resource awareness, the capability of users or user agents to have knowledge about the existence and state of resources, is required in order utilize the resource. This awareness requires a description of the services and resources typically defined via a community-agreed information model. One of the most popular information models, used by a number of Grid infrastructures, is the GLUE Schema, which provides a common language for describing Grid resources. Other approaches exist, however they follow different modeling strategies. The presence of different flavors of information models for Grid resources is a barrier for enabling inter-Grid interoperability. In order to solve this problem, the GLUE Working Group in the context of the Open Grid Forum was started. The purpose of the group is to oversee a major redesign of the GLUE Schema which should consider the successful modeling choices and flaws that have emerged from practical experience and modeling choices from other initiatives. In this paper, we present the status of the new model for describing computing resources as the first output from the working group with the aim of dissemination and soliciting feedback from the community

  19. Effect of fibrin glue on the biomechanical properties of human Descemet's membrane.

    Directory of Open Access Journals (Sweden)

    Shyam S Chaurasia

    Full Text Available BACKGROUND: Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10-15 µm in thickness, Descemet's membrane (DM is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG on the biomechanical properties of DM using atomic force microscopy (AFM and relates these properties to membrane folding propensity. METHODOLOGY/PRINCIPAL FINDINGS: Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the "rolling up" tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. CONCLUSIONS/SIGNIFICANCE: Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity.

  20. Effect of Fibrin Glue on the Biomechanical Properties of Human Descemet's Membrane

    Science.gov (United States)

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Li, Ang; Poh, Rebekah; Tan, Xiao Wei; Lakshminarayanan, Rajamani; Lim, Chwee T.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Background Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK) to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK) performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10–15 µm in thickness), Descemet's membrane (DM) is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG) on the biomechanical properties of DM using atomic force microscopy (AFM) and relates these properties to membrane folding propensity. Methodology/Principal Findings Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the “rolling up” tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM) and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. Conclusions/Significance Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity. PMID:22662156

  1. Posterior reversible leukoencephalopathy syndrome secondary to hepatic transarterial chemoembolization with doxorubicin drug eluting beads

    Science.gov (United States)

    Kistler, C. Andrew; McCall, Joseph Caleb; Ghumman, Saad Sultan; Ali, Ijlal Akbar

    2014-01-01

    Posterior reversible encephalopathy syndrome (PRES) is a rare complication of transarterial chemoembolization (TACE) used to treat liver metastases and has never been reported in a patient with metastatic uveal melanoma (UM) to the liver. We report the first case of PRES secondary to TACE with drug eluting beads (DEBs) loaded with doxorubicin in a 56-year-old woman with metastatic UM to the liver. PMID:24772346

  2. The use of snake venom derived fibrin glue in hysterorrhaphy of ovine caesarean surgery

    OpenAIRE

    CHALHOUB, M.; PRESTES, N. C.; LOPES, M. D.; ROCHA, N. S.; THOMAZINI-SANTOS, I. A.; MENDES-GIANNINI, M.J.

    2000-01-01

    Fibrin glue has been used on its own or in conjunction with suturing materials to promote hemostasis, reduce adherence, strengthen the wound site, and improve healing. Snake venom derived fibrin glue was evaluated as an alternative to conventional uterine suturing after ovine caesarean surgery. Twenty-eight pregnant ewes of known mating date were used. The animals submitted to conventional caesarean sections showed a better wound healing process. As expected, all the operated animals had reta...

  3. A comparative study of tissue glue and vicryl suture for conjunctival and scleral closure in conventional 20-gauge vitrectomy.

    Science.gov (United States)

    Batman, C; Ozdamar, Y; Mutevelli, S; Sonmez, K; Zilelioglu, G; Karakaya, J

    2009-06-01

    To describe the use of tissue glue to close scleral and conjunctival wounds, and to compare the clinical outcomes using tissue glue and vicryl suture for closing these areas in conventional 20-gauge (G) vitrectomy. Thirty eyes of 30 patients were included in this study. The indications for vitreoretinal surgery were diabetic vitreous haemorrhage with severe vitreoretinal traction in 10 eyes, retinal detachment and proliferative vitreoretinopathy in 14 eyes, and vitreous opacity in 6 eyes. Tissue glue (Tisseel, Baxter AG Industries, Vienna, Austria) was used to attach scleral and conjunctival wounds in 15 eyes and vicryl sutures in 15 eyes. The patients were allotted into two subgroups as tissue glue group (TG) and vicryl suture group (VG). The sclerotomy sites were evaluated with ultrasound biomicroscopy (UBM) postoperatively in TG. Follow-up period was 2 months. The groups were statistically compared for ocular signs and symptoms by Mann-Whitney U-test. No scleral wound leakage and conjunctival reattachment were observed at the end of the surgical procedure and during the follow-up period. No adverse effects were seen in TG. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of UBM in TG. Patient comfort was significantly higher in TG than VG (P<0.05). Tissue glue has no adverse effects on ocular tissue and can be used as a substitute for suture materials, and the use of tissue glue decreases patient symptoms during the postoperative period after 20-G vitrectomy. Tissue glue can enable to perform sutureless surgery in the conventional 20-G vitrectomy.

  4. Tests of optical glues for the PANDA electromagnetic calorimeter

    NARCIS (Netherlands)

    Dbeyssi, A.; Tomasi-Gustafsson, E.; Hennino, T.; Imre, M.; Kunne, R.; Le Galliard, C.; Marchand, D.; Maroni, A.; Ramstein, B.; Rosier, P.; Bremer, D.; Dormenev, V.; Eissner, T.; Kuske, T.; Novotny, R.; Moeini, H.; Bondarenko, O.; Kavatsyuk, M.; Loehner, H.; Messchendorp, G.; Tambave, G.

    2013-01-01

    This paper reports on the results of tests for low temperature applications of two commercial optical glues in the electromagnetic calorimeter of PANDA at FAIR. Mechanical, thermal and optical properties are presented, as well as radiation hardness to photon and proton radiation. (C) 2013 Elsevier

  5. Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall.

    Science.gov (United States)

    Ortillés, Á; Pascual, G; Peña, E; Rodríguez, M; Pérez-Köhler, B; Mesa-Ciller, C; Calvo, B; Bellón, J M

    2017-11-01

    The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Comparação das técnicas transarterial e de estimulação de múltiplos nervos para bloqueio do plexo braquial por via axilar usando lidocaína com epinefrina Comparación de las técnicas transarterial y de estimulación de múltiples nervios para bloqueo del plexo braquial por vía axilar usando lidocaína con epinefrina Comparison of transarterial and multiple nerve stimulation techniques for axillary block using lidocaine with epinephrine

    OpenAIRE

    Luiz Eduardo Imbelloni; Lúcia Beato; José Antônio Cordeiro

    2005-01-01

    JUSTIFICATIVA E OBJETIVOS: A técnica transarterial com grandes doses de anestésico local resulta em alta efetividade para o bloqueio axilar do plexo braquial. A técnica utilizando múltiplos estímulos exige mais tempo e maior experiência. Este estudo prospectivo compara a latência e o índice de sucesso do bloqueio do plexo braquial usando duas técnicas de localização: transarterial ou múltipla estimulação dos nervos. MÉTODO: A lidocaína com epinefrina, 800 mg, foi usada inicialmente para o blo...

  7. Properties of invariant modelling and invariant glueing of vector fields

    International Nuclear Information System (INIS)

    Petukhov, V.R.

    1987-01-01

    Invariant modelling and invariant glueing of both continuous (rates and accelerations) and descrete vector fields, gradient and divergence cases are considered. The following appendices are discussed: vector fields in crystals, crystal disclinations, topological charges and their fields

  8. Endoscopic use of cyanoacrylate glue in the treatment of urethral fistula

    Directory of Open Access Journals (Sweden)

    Andre Ramos Sorgi Macedo

    2013-07-01

    Full Text Available Purpose The aim of this video is to demonstrate an endoscopic and minimally invasive repair of an urethrocutaneous fistula with cyanoacrylate glue. Materials and Methods: A 56 year-old-man with post-infectious urethral stricture and recurrent perineal abscess formation due to urethral fistulas. Results The operative time was 60 minutes, no major complications were observed perioperatively and postoperatively. At a follow-up time of 6 months the patient had no evidence of recurrent fistula and abscess formation. CONCLUSIONS The endoscopic use of cyanoacrylate glue represents a safe and minimally invasive approach that might be offered as a first line option for the treatment of urinary fistulas in selected patients, especially those with narrow and long tracts.

  9. Glasses, Coatings, Glues and Gamma-ray Irradiation

    International Nuclear Information System (INIS)

    Barcala, J.M.; Fernandez, M. G.; Ferrando, A.; Fuentes, J.; Josa, M. I.; Molinero, A.; Oller, J. C.; Arce, P.; Calvo, E.; Figueroa, C. F.; Rodrigo, T.; Vila, I.; Virto, A. L.; Beigveder, J. M.; Genova, I.; Perez, G.; Ruiz, J. A.

    2001-01-01

    Most of the alignment systems for LHC experiments use optomechanical elements confirming a network of points that are monitored by laser beams. LHC experiments, working at the expected nominal luminosity, will induce an extremely high irradiation. basic components such as glasses, coatings and glues may change and their performance may degrade significantly. We have tested various components and identified some of them that can stand 10 years of LHC operation. (Author) 11 refs

  10. Glasses, Coatings, Glues and Gamma-ray Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Barcala, J.M.; Fernandez, M. G.; Ferrando, A.; Fuentes, J.; Josa, M. I.; Molinero, A.; Oller, J. C. [Ciemat. Madrid (Spain); Arce, P.; Calvo, E.; Figueroa, C. F.; Rodrigo, T.; Vila, I.; Virto, A. L. [Universidad de Cantabria. Santander (Spain); Beigveder, J. M.; Genova, I.; Perez, G.; Ruiz, J. A. [CIDA. Madrid (Spain)

    2001-07-01

    Most of the alignment systems for LHC experiments use optomechanical elements confirming a network of points that are monitored by laser beams. LHC experiments, working at the expected nominal luminosity, will induce an extremely high irradiation. basic components such as glasses, coatings and glues may change and their performance may degrade significantly. We have tested various components and identified some of them that can stand 10 years of LHC operation. (Author) 11 refs.

  11. Successful Endoscopic Management of Non-Healing Perforated Duodenal Ulcer with Polyglycolic Acid Sheet and Fibrin Glue.

    Science.gov (United States)

    Mishiro, Tsuyoshi; Shibagaki, Kotaro; Matsuda, Kayo; Fukuyama, Chika; Okada, Mayumi; Mikami, Hironobu; Izumi, Daisuke; Yamashita, Noritsugu; Okimoto, Eiko; Fukuda, Naoki; Aimi, Masahito; Fukuba, Nobuhiko; Oshima, Naoki; Takanashi, Toshihiro; Matsubara, Takeshi; Ishimura, Norihisa; Ishihara, Shunji; Kinoshita, Yoshikazu

    2016-08-01

    In recent years, treatment techniques in which polyglycolic acid sheets are applied to various situations with fibrin glue have exhibited great clinical potential, and previous studies have reported safety and efficacy. We describe closure of a non-healing perforated duodenal ulcer with the use of a polyglycolic acid sheet and fibrin glue in an elderly patient who was not a candidate for surgery.

  12. Fibrin glue mixed with platelet-rich fibrin as a scaffold seeded with dental bud cells for tooth regeneration.

    Science.gov (United States)

    Yang, Kai-Chiang; Wang, Chun-Hao; Chang, Hao-Hueng; Chan, Wing P; Chi, Chau-Hwa; Kuo, Tzong-Fu

    2012-11-01

    Odontogenesis is a complex process with a series of epithelial-mesenchymal interactions and odontogenic molecular cascades. In tissue engineering of teeth from stem cells, platelet-rich fibrin (PRF), which is rich in growth factors and cytokines, may improve regeneration. Accordingly, PRF was added into fibrin glue to enrich the microenvironment with growth factors. Unerupted second molar tooth buds were harvested from miniature swine and cultured in vitro for 3 weeks to obtain dental bud cells (DBCs). Whole blood was collected for the preparation of PRF and fibrin glue before surgery. DBCs were suspended in fibrin glue and then enclosed with PRF, and the DBC-fibrin glue-PRF composite was autografted back into the original alveolar sockets. Radiographic and histological examinations were used to identify the regenerated tooth structure 36 weeks after implantation. Immunohistochemical staining was used to detect proteins specific to tooth regeneration. One pig developed a complete tooth with crown, root, pulp, enamel, dentin, odontoblast, cementum, blood vessels, and periodontal ligaments in indiscriminate shape. Another animal had an unerupted tooth that expressed cytokeratin 14, dentin matrix protein-1, vascular endothelial growth factor, and osteopontin. This study demonstrated, using autogenic cell transplantation in a porcine model, that DBCs seeded into fibrin glue-PRF could regenerate a complete tooth. Copyright © 2011 John Wiley & Sons, Ltd.

  13. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  14. SU-F-T-141: Proton Dose Validation in a Phantom Beyond TRUFILL N-BCA Embolization Glue

    International Nuclear Information System (INIS)

    Mandapaka, A; Ghebremedhin, A; Patyal, B; Linda, Loma

    2016-01-01

    Purpose: To validate the treatment planning system predicted proton dose beyond a heterogeneity (n-BCA glue) by making a measurement in a custom acrylic phantom. Methods: A custom cubic acrylic phantom was designed for this experiment. A container was designed to fit in the phantom. This container was filled with TRUFILL™ n-Butyl Cyanoacrylate(n-BCA) glue. When the container was placed in the phantom, its center was at a distance of 7.4cm from the entrance. This depth allows us to make measurements around the center of modulation of a 126 MeV proton beam with a 3cm spread-out-Bragg peak. To make measurements at other beam energies, additional acrylic can be added in front of the phantom, to adjust the depth of the heterogeneity. A diamond detector was cross calibrated against a standard cylindrical ion chamber in a 126MeV beam. The diamond detector was then used to make dose measurements beyond the inhomogeneity. The measurement was repeated with the container filled with water. Several measurements were made at each setup, to check reproducibility of measurements. Results: For the same number of Tic3R1 counts, the dose measured with the diamond detector beyond n-BCA glue was 1.053 times the dose measured beyond the water filled container. This result is in agreement with the measured stopping power of glue (1.06). These measurements were in agreement with the dose predicted by the treatment planning system when the electron density of the heterogeneity was replaced with 1.06 before the dose calculation. Conclusion: Our initial measurements validate the dose predicted by our treatment plan in the presence of heterogeneity in a phantom. The material tested (n-BCA glue) is commonly used in the treatment of AVM’s prior to an SRS treatment. An error in dose predicted by the treatment plan in the presence of the glue can be detrimental in a single fraction high dose SRS treatment I received the n-BCA liquid embolic system samples from Codman and Shurtleff, Inc.

  15. SU-F-T-141: Proton Dose Validation in a Phantom Beyond TRUFILL N-BCA Embolization Glue

    Energy Technology Data Exchange (ETDEWEB)

    Mandapaka, A; Ghebremedhin, A; Patyal, B; Linda, Loma [University Medical Center, Loma Linda, CA (United States)

    2016-06-15

    Purpose: To validate the treatment planning system predicted proton dose beyond a heterogeneity (n-BCA glue) by making a measurement in a custom acrylic phantom. Methods: A custom cubic acrylic phantom was designed for this experiment. A container was designed to fit in the phantom. This container was filled with TRUFILL™ n-Butyl Cyanoacrylate(n-BCA) glue. When the container was placed in the phantom, its center was at a distance of 7.4cm from the entrance. This depth allows us to make measurements around the center of modulation of a 126 MeV proton beam with a 3cm spread-out-Bragg peak. To make measurements at other beam energies, additional acrylic can be added in front of the phantom, to adjust the depth of the heterogeneity. A diamond detector was cross calibrated against a standard cylindrical ion chamber in a 126MeV beam. The diamond detector was then used to make dose measurements beyond the inhomogeneity. The measurement was repeated with the container filled with water. Several measurements were made at each setup, to check reproducibility of measurements. Results: For the same number of Tic3R1 counts, the dose measured with the diamond detector beyond n-BCA glue was 1.053 times the dose measured beyond the water filled container. This result is in agreement with the measured stopping power of glue (1.06). These measurements were in agreement with the dose predicted by the treatment planning system when the electron density of the heterogeneity was replaced with 1.06 before the dose calculation. Conclusion: Our initial measurements validate the dose predicted by our treatment plan in the presence of heterogeneity in a phantom. The material tested (n-BCA glue) is commonly used in the treatment of AVM’s prior to an SRS treatment. An error in dose predicted by the treatment plan in the presence of the glue can be detrimental in a single fraction high dose SRS treatment I received the n-BCA liquid embolic system samples from Codman and Shurtleff, Inc.

  16. Role of cyanoacrylate glue therapy in enteral SEMS bleeding - A nightmare

    Directory of Open Access Journals (Sweden)

    Virukalpatti Goparathinam Mohanprasad

    2013-01-01

    Full Text Available Over the past century, the use of stents has evolved to a point where they are now used extensively throughout the gastrointestinal tract. Endoscopic stenting has become widely used for treatment of gastrointestinal and hepatobiliary strictures. Metallic stents are deployed in malignant strictures as a palliative procedure. Adverse events of stenting include perforation, migration, bleeding, occlusion, and pain. Finally, the use of multidisciplinary teams which include endoscopists, interventional radiologists, and surgeons allows for the exchange of ideas and procedural planning necessary for successful innovation. We present a case of successful cessation of bleeding by using cyanoacrylate glue therapy in post-enteral self-expandable metallic stent bleeding. In conclusion, glue therapy may also be considered as a mode of treatment other than conservative approach and angiographic coil embolization.

  17. Lifetime Improvement of Organic Light Emitting Diodes using LiF Thin Film and UV Glue Encapsulation

    Science.gov (United States)

    Huang, Jian-Ji; Su, Yan-Kuin; Chang, Ming-Hua; Hsieh, Tsung-Eong; Huang, Bohr-Ran; Wang, Shun-Hsi; Chen, Wen-Ray; Tsai, Yu-Sheng; Hsieh, Huai-En; Liu, Mark O.; Juang, Fuh-Shyang

    2008-07-01

    This work demonstrates the use of lithium fluoride (LiF) as a passivation layer and a newly developed UV glue for encapsulation on the LiF passivation layer to enhance the stability of organic light-emitting devices (OLEDs). Devices with double protective layers showed a 25-fold increase in operational lifetime compared to those without any packaging layers. LiF has a low melting point and insulating characteristics and it can be adapted as both a protective layer and pre-encapsulation film. The newly developed UV glue has a fast curing time of only 6 s and can be directly spin-coated onto the surface of the LiF passivation layer. The LiF thin film plus spin-coated UV glue is a simple packaging method that reduces the fabrication costs of OLEDs.

  18. Clinical experience of intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer

    International Nuclear Information System (INIS)

    Nishino, Takeshi; Takizawa, Hiromitsu; Yoshida, Mitsuteru; Kawakami, Yukikiyo; Sakiyama, Shoji; Kondo, Kazuya

    2014-01-01

    Secondary pneumothorax with advanced lung cancer is an intractable and serious pathosis, which directly aggravates patients' Quality of Life (QOL) and prognosis. We first select the intrapleural administration of fibrin glue for secondary pneumothorax with advanced lung cancer. From April 2009 to May 2012, we encountered 5 patients who developed secondary pneumothorax during treatment for advanced lung cancer. Their average age was 60.8 years old, and 4 of them had squamous cell carcinoma, 1 had adenocarcinoma, and all had unresectable advanced lung cancer. In 4 of them, the point of air leakage could be detected by pleurography, and leakage could be stopped by the intrapleural administration of fibrin glue. All of them could receive chemotherapy or radiotherapy after treatment for secondary pneumothorax. The intrapleural administration of fibrin glue may be an effective and valid treatment for intractable secondary pneumothorax with advanced lung cancer. (author)

  19. Generalized Likelihood Uncertainty Estimation (GLUE) Using Multi-Optimization Algorithm as Sampling Method

    Science.gov (United States)

    Wang, Z.

    2015-12-01

    For decades, distributed and lumped hydrological models have furthered our understanding of hydrological system. The development of hydrological simulation in large scale and high precision elaborated the spatial descriptions and hydrological behaviors. Meanwhile, the new trend is also followed by the increment of model complexity and number of parameters, which brings new challenges of uncertainty quantification. Generalized Likelihood Uncertainty Estimation (GLUE) has been widely used in uncertainty analysis for hydrological models referring to Monte Carlo method coupled with Bayesian estimation. However, the stochastic sampling method of prior parameters adopted by GLUE appears inefficient, especially in high dimensional parameter space. The heuristic optimization algorithms utilizing iterative evolution show better convergence speed and optimality-searching performance. In light of the features of heuristic optimization algorithms, this study adopted genetic algorithm, differential evolution, shuffled complex evolving algorithm to search the parameter space and obtain the parameter sets of large likelihoods. Based on the multi-algorithm sampling, hydrological model uncertainty analysis is conducted by the typical GLUE framework. To demonstrate the superiority of the new method, two hydrological models of different complexity are examined. The results shows the adaptive method tends to be efficient in sampling and effective in uncertainty analysis, providing an alternative path for uncertainty quantilization.

  20. Glue-Sniffing: A Comparison Study of Sniffers and Non-Sniffers.

    Science.gov (United States)

    Jansen, P.; And Others

    1992-01-01

    Compared 22 glue sniffers and 22 nonsniffers from group of street children and adolescents living in supervised shelters. Found no statistically significant differences between groups on cognitive measures or biographical features. Shelter staff rated sniffers as significantly more disturbed in their relationships with others, although…

  1. Mussel glue protein has an open conformation.

    Science.gov (United States)

    Williams, T; Marumo, K; Waite, J H; Henkens, R W

    1989-03-01

    Both native glue protein from marine mussels and a synthetic nonhydroxylated analog were analyzed by far-uv CD under a variety of conditions. Analysis of the CD spectra using various models strongly suggest a primarily random coil structure for both forms of the protein, a fact also supported by the absence of spectral change for the glue protein upon dilution into 6 M guanidine hydrochloride. The nonhydroxylated analog, which consists of 20 repeats of the peptide sequence Ala-Lys-Pro-Ser-Tyr-Pro-Pro-Thr-Tyr-Lys, was further characterized by enzyme modification using mushroom tyrosinase. Enzymatic hydroxylation of tyrosines was found to be best fit by a model containing two rate constants, 5.6 (+/- 0.6) X 10(-3) and 7.2 (+/- 0.3) X 10(-2) min-1. At equilibrium, HPLC analysis of digests showed nearly 100% conversion of Tyr-9 and only 15 to 35% conversion of Tyr-5. The Chou and Fasman rules for predicting structure were applied to the repeat sequence listed above. The rules predict the absence of alpha helix and beta pleated sheets in the structure of this peptide. On the other hand, beta turns are predicted to be present with Tyr-5 being in the region of highest probability. These data suggest that the protein in solution has only a small amount of secondary structure.

  2. Endoscopic ultrasound-guided coil or glue injection in post-cyanoacrylate gastric variceal re-bleed.

    Science.gov (United States)

    Mukkada, Roy J; Antony, Rajesh; Chooracken, Mathew J; Francis, Jose V; Chettupuzha, Antony P; Mathew, Pradeep G; Augustine, Philip; Koshy, Abraham

    2018-04-09

    N-butyl-cyanoacrylate injection is recommended in bleeding/recently bled gastric varices. However, cyanoacrylate injection is associated with re-bleed in 25% to 50% of patients. Endoscopic ultrasound (EUS)-guided coil application is an emerging treatment modality for bleeding gastric varices. The aim of this study was to compare EUS-guided coil application combined with or without cyanoacrylate glue injection to injection alone in post-glue gastric variceal re-bleed. A retrospective analysis of a prospectively maintained database was performed. Thirty patients who re-bled after cyanoacrylate injection and who had EUS-guided coil application to gastric varices were included. The comparison was done with data of 51 patients who had only repeat cyanoacrylate injection. Both groups had a follow up for 12 months. EUS-guided coil application was done under endosonographic guidance. A single coil was placed in 7, two coils in each of 13 patients, three in 5, four in 3, five in one, and 6 coils in one patient. In addition, cyanoacrylate glue injection was given in 15 patients. Eight patients had repeat EUS-guided coil application 1 month later. Re-bleed and mortality were assessed. Coilng: Six out of 30 (20%) patients re-bled during follow up of 9 to 365 days. Three out of 30 (10%) died. One patient died 9 days after the procedure due to acute respiratory distress syndrome, one died 4 months after the procedure due to a re-bleed and one 5 months after the procedure due to spontaneous bacterial peritonitis. Glue only: 26/51 (51%) re-bled during follow up of 45 to 365 days. EUS-guided coil application resulted in significantly less re-bleed than glue-only (Kaplan-Meir survival analysis with log-rank test, z = 5.4, p guided coil application with/without cyanoacrylate injection for the obliteration of gastric varices is effective for post-cyanoacrylate gastric variceal re-bleed.

  3. Transarterial ethanol ablation for sporadic and non-hemorrhaging angiomyolipoma in the kidney

    International Nuclear Information System (INIS)

    Takebayashi, Shigeo; Horikawa, Ayumi; Arai, Mito; Iso, Shinichiroh; Noguchi, Kazumi

    2009-01-01

    Purpose: We evaluated the efficacy and side effects of transarterial ethanol ablation in sporadic and non-hemorrhaging angiomyolipomas (AMLs) in the kidney. Material and Methods: A total of 10 patients with solitary and sporadic AMLs underwent selective transarterial absolute ethanol ablation for prophylaxis against hemorrhage. We confirmed the ratio areas of tumor vessel on angiogram, those of infraction on post-ablation computed tomography (CT) and those of tumor reduction in a 3-, 6- and 12-month follow-up CT. Results: Once or twice a single infusion of 1 or 2 ml absolute ethanol achieved in a total occlusion of 22 feeding arteries which consisted of 7 proximal interlobar arteries, 12 distal interlobar arteries and 3 renal capsular arteries. Nontarget occlusion did not occur by ethanol reflux in any cases but occurred causing spasms provoked by repeated inflation and deflation of the balloon in one case. Total occlusion of tumor vessels was observed in 7 patients and 92-95% occlusion in 3. Ethanol ablation produced 1.8-22.5% (mean 8.4 ± 6.8%) areas of infarctions but the outcome was not serious in all cases. Mean percentage areas of tumor reduction were 29.4 ± 10.6% in a 3-month follow-up, 45.7 ± 11.9% in a 6-month and 59.3 ± 11.5% in a 12-month follow-up. Conclusions: Absolute ethanol ablation for sporadic and non-hemorrhaging AML is safe and effective in reducing majority of tumor area in a 1-year follow-up.

  4. Transarterial embolization in head and neck lesions

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Han, Man Chung

    1985-01-01

    The transarterial embolization procedures have been performed in a total of 38 patients with head and neck lesions, including 5 carotid-cavernous fistulas, 1 internal carotid aneurysm, 10 meningiomas, 16 nasopharyngeal angiofibromas, 1 post-traumatic epistaxis and 5 other vascular tumors, over the 18 months-period. Six cases of C-C fistula and ICA aneurysm were treated with the detachable balloon catheter technique. The meningiomas, angiofibromas and all other lesions were embolized with superselection of the branches of the external carotid artery such as the internal maxillary, the middle meningeal, the ascending pharyngeal the facial or other branches, using Berenstein superselective catheters or conventional angiographic catheters. The PVA (polyvinyl alcohol foam) and/or Gelfoam particles were used as embolic materials in these cases. Most of the lesions were successfully embolized with minor transient complications such as pain, headache, vomiting, fever and etc. But in 4 cases occurred the serious complications; one cerebral hemorrhage, two cerebral infarctions, and one acute laryngeal edema. The selection of the embolic materials and the catheters, and the complications are briefly discussed

  5. Transarterial embolization in head and neck lesions

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Hyun; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1985-06-15

    The transarterial embolization procedures have been performed in a total of 38 patients with head and neck lesions, including 5 carotid-cavernous fistulas, 1 internal carotid aneurysm, 10 meningiomas, 16 nasopharyngeal angiofibromas, 1 post-traumatic epistaxis and 5 other vascular tumors, over the 18 months-period. Six cases of C-C fistula and ICA aneurysm were treated with the detachable balloon catheter technique. The meningiomas, angiofibromas and all other lesions were embolized with superselection of the branches of the external carotid artery such as the internal maxillary, the middle meningeal, the ascending pharyngeal the facial or other branches, using Berenstein superselective catheters or conventional angiographic catheters. The PVA (polyvinyl alcohol foam) and/or Gelfoam particles were used as embolic materials in these cases. Most of the lesions were successfully embolized with minor transient complications such as pain, headache, vomiting, fever and etc. But in 4 cases occurred the serious complications; one cerebral hemorrhage, two cerebral infarctions, and one acute laryngeal edema. The selection of the embolic materials and the catheters, and the complications are briefly discussed.

  6. Gravity: The Glue of the Universe. History and Activities.

    Science.gov (United States)

    Gilbert, Harry; Smith, Diana Gilbert

    This book presents a story of the history of gravity, the glue of the universe, and is based on two premises: (1) an understanding of mathematics is not required to grasp the concepts and implications of relativity; and (2) relativity has altered forever the perceptions of gravity, space, time, and how the universe works. A narrative text section…

  7. Hypokalemic muscular paralysis causing acute respiratory failure due to rhabdomyolysis with renal tubular acidosis in a chronic glue sniffer.

    Science.gov (United States)

    Kao, K C; Tsai, Y H; Lin, M C; Huang, C C; Tsao, C Y; Chen, Y C

    2000-01-01

    A 34-year-old male was admitted to the emergency department with the development of quadriparesis and respiratory failure due to hypokalemia after prolonged glue sniffing. The patient was subsequently given mechanical ventilatory support for respiratory failure. He was weaned from the ventilator 4 days later after potassium replacement. Toluene is an aromatic hydrocarbon found in glues, cements, and solvents. It is known to be toxic to the nervous system, hematopoietic system, and causes acid-base and electrolyte disorders. Acute respiratory failure with hypokalemia and rhabdomyolysis with acute renal failure should be considered as potential events in a protracted glue sniffing.

  8. Staple line reinforcement with fleece-coated fibrin glue (TachoComb) after thoracoscopic bullectomy for the treatment of spontaneous pneumothorax

    International Nuclear Information System (INIS)

    Muramatsu, Takashi; Ohmori, Kazumitsu; Shimamura, Mie; Furuichi, Motohiko; Takeshita, Shinji; Negishi, Nanao

    2007-01-01

    We investigated the cause of pneumothorax recurrence after thoracoscopic surgery and the effectiveness of staple line reinforcement with fleece-coated fibrin glue (TachoComb) in the prevention of postoperative pneumothorax recurrence. From April 3, 1992 to the end of December 2005, thoracoscopic bullectomy was performed on 499 patients of primary spontaneous pneumothorax. The causes of recurrence were investigated on 39 patients on the basis of surgical observations, preoperative chest computed tomography, and so on. The most common cause was new bulla formation (37 cases), 19 of which were apparently related to the staple line (within 1 cm of the staple lines) and 15 of which were not related to the staple line. After 2000, we stopped using forceps to grasp lungs and we have reinforced the staple line by applying fleece-coated fibrin glue. The staple line reinforced with fleece-coated fibrin glue, or sprayed with fibrin glue solution and the untreated group (bullectomy only with staples) were compared, and the recurrence rates were 1.22%, 7.25%, and 10.00%, respectively (P=0.0006021). The recurrence rate after thoracoscopic bullectomy with fleece-coated fibrin glue was significantly lowered and we consider this procedure to be the treatment of choice for the management of spontaneous pneumothorax. (author)

  9. Towards GLUE2 evolution of the computing element information model

    CERN Document Server

    Andreozzi, S; Field, L; Kónya, B

    2008-01-01

    A key advantage of Grid systems is the ability to share heterogeneous resources and services between traditional administrative and organizational domains. This ability enables virtual pools of resources to be created and assigned to groups of users. Resource awareness, the capability of users or user agents to have knowledge about the existence and state of resources, is required in order utilize the resource. This awareness requires a description of the services and resources typically defined via a community-agreed information model. One of the most popular information models, used by a number of Grid infrastructures, is the GLUE Schema, which provides a common language for describing Grid resources. Other approaches exist, however they follow different modeling strategies. The presence of different flavors of information models for Grid resources is a barrier for enabling inter-Grid interoperability. In order to solve this problem, the GLUE Working Group in the context of the Open Grid Forum was started. ...

  10. Is there need for baryons with constituent glue

    International Nuclear Information System (INIS)

    Meissner, U.G.

    1983-01-01

    We investigate the breathing-mode spectrum of the Λ-particle in the framework of a general bag model including confinement via surface tension and volume energy. We show that the experimental states Λ 1/2 (1600) and Λ 1/2 (1800) can be described as radial surface excitations of the Λ. We further comment on a recent paper describing these Λ-excitations as baryons with constituent glue. (orig.)

  11. Using the DP-190 glue for adhesive attachment of a large space mirror and its rim

    Science.gov (United States)

    Vlasenko, Oleg; Zverev, Alexey; Sachkov, Mikhail

    2014-07-01

    The glue DP-190 is widely used for adhesive attachment of astrositall (zerodur) lightweight large-size space astronomical mirrors (diameter of 1.7 m and more) with elements of their frames of invar. Peculiarities of physicalmechanical behavior of the glue DP-190 when exposed to the environment during the ground operation and in orbit cause instability of the reflective surface quality of mirrors. In this report we show that even a small (around 1%-5%) volumetric deformation of a cylindrical adhesive layer with a thickness of 0.8 mm between the mirror and the rim element causes significant mirrors deformation. We propose to use adhesive layer of special form that allows to reduce volumetric deformations of the glue DP-190 up to three times. Here we present results based on primary mirror tests of the WSO-UV project.

  12. [The influence of biological compatibility of the cyanoacrylate glue on regeneration of the cartilaginous tissue].

    Science.gov (United States)

    Semenov, F V; Skibitskaya, N F

    The objective of the present study was to evaluate the possibility of the application of the cyanoacrylate-based glue for the strengthening of the reconstructed elements of the middle ear and its influence on the regeneration of the cartilaginous tissue. We used the cartilaginous tissue from the auricles of the male California rabbits as a model. The cartilage was destroyed in a standard press. Half of the cartilage thus fragmented was implanted into the left auricle. The remaining part was mixed up with the cyanoacrylate glue and implanted into the right auricle of the same animal. The implanted material was used for the morphological study on day 10, within 1 and 2 months after the beginning of the experiment. The results of the study confirm the absence of the toxic action of the biologically compatible cyanoacrylate-based glue on the regeneration of the cartilaginous and connective tissues which suggests the possibility of its application for the surgical treatment of the diseases of the middle ear.

  13. Determining characteristic principal clusters in the “cluster-plus-glue-atom” model

    International Nuclear Information System (INIS)

    Du, Jinglian; Wen, Bin; 2NeT Lab, Wilfrid Laurier University, Waterloo, 75 University Ave West, Ontario N2L 3C5 (Canada))" data-affiliation=" (M2NeT Lab, Wilfrid Laurier University, Waterloo, 75 University Ave West, Ontario N2L 3C5 (Canada))" >Melnik, Roderick; Kawazoe, Yoshiyuki

    2014-01-01

    The “cluster-plus-glue-atom” model can easily describe the structure of complex metallic alloy phases. However, the biggest obstacle limiting the application of this model is that it is difficult to determine the characteristic principal cluster. In the case when interatomic force constants (IFCs) inside the cluster lead to stronger interaction than the interaction between the clusters, a new rule for determining the characteristic principal cluster in the “cluster-plus-glue-atom” model has been proposed on the basis of IFCs. To verify this new rule, the alloy phases in Cu–Zr and Al–Ni–Zr systems have been tested, and our results indicate that the present new rule for determining characteristic principal clusters is effective and reliable

  14. Clinical evaluations of complete autologous fibrin glue, produced by the CryoSeal® FS system, and polyglycolic acid sheets as wound coverings after oral surgery.

    Science.gov (United States)

    Kouketsu, Atsumu; Nogami, Shinnosuke; Yamada-Fujiwara, Minami; Nagai, Hirokazu; Yamauchi, Kensuke; Mori, Shiro; Miyashita, Hitoshi; Kawai, Tadashi; Matsui, Aritsune; Kataoka, Yoshihiro; Satomi, Norihisa; Ezoe, Yushi; Abe, Satoko; Takeda, Yuri; Tone, Takeshi; Hirayama, Bunnichi; Kurobane, Tsuyoshi; Tashiro, Kazuki; Yanagisawa, Yuta; Takahashi, Tetsu

    2017-09-01

    The CryoSeal ® FS System has been recently introduced as an automated device for the production of complete fibrin glue from autologous plasma, rather than from pool allogenic or cattle blood, to prevent viral infection and allergic reaction. We evaluated the effectiveness of complete autologous fibrin glue and polyglycolic acid (PGA) sheet wound coverings in mucosa defect oral surgery. Postoperative pain, scar contracture, ingestion, tongue dyskinesia, and postoperative bleeding were evaluated in 12 patients who underwent oral (including the tongue) mucosa excision, and received a PGA sheet and an autologous fibrin glue covering. They were compared with 12 patients who received a PGA sheet and commercial allogenic fibrin glue. All cases in the complete autologous fibrin glue group demonstrated good wound healing without complications such as local infection or incomplete cure. All evaluated clinical measures in this group were similar or superior to the commercial allogenic fibrin glue group. Coagulation and adhesion quality achieved with this method was comparable to that with a PGA sheet and commercial fibrin glue. Covering oral surgery wounds with complete autologous fibrin glue produced by an automated device was convenient, safe, and reduced the risk of viral infection and allergic reaction associated with conventional techniques. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  15. Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty.

    Science.gov (United States)

    Sun, Ping; Cheng, Xiang; Deng, Shichang; Hu, Qinggang; Sun, Yi; Zheng, Qichang

    2017-02-07

    Chronic pain following mesh-based inguinal hernia repair is frequently reported, and has a significant impact on quality of life. Whether mesh fixation with glue can reduce chronic pain without increasing the recurrence rate is still controversial. To determine whether tissue adhesives can reduce postoperative complications, especially chronic pain, with no increase in recurrence rate, compared with sutures for mesh fixation in Lichtenstein hernia repair. We searched the following electronic databases with no language restrictions: the Cochrane Central Register of Controlled Trials (CENTRAL; issue 4, 2016) in the Cochrane Library (searched 11 May 2016), MEDLINE Ovid (1986 to 11 May 2016), Embase Ovid (1986 to 11 May 2016), Science Citation Index (Web of Science) (1986 to 11 May 2016), CBM (Chinese Biomedical Database), CNKI (China National Knowledge Infrastructure), VIP (a full-text database in China), Wanfang databases. We also checked reference lists of identified papers (included studies and relevant reviews). We included all randomised and quasi-randomised controlled trials comparing glue versus sutures for mesh fixation in Lichtenstein hernia repair. Cluster-RCTs were also eligible. Two review authors extracted data and assessed the risk of bias independently. Dichotomous outcomes were expressed as odds ratio (OR) with 95% confidence intervals (CI). Continuous outcomes were expressed as mean differences (MD) with 95% CIs. Twelve trials with a total of 1932 participants were included in this review. The overall postoperative chronic pain in the glue group was reduced by 37% (OR 0.63, 95% CI 0.44 to 0.91; 10 studies, 1418 participants, low-quality evidence) compared with the suture group. However, the results changed when we conducted subgroup analysis with regard to the type of mesh. Subgroup analysis of included studies using lightweight mesh showed the reduction of chronic pain was less profound and insignificant (OR 0.77, 95% CI 0.50 to 1.17). Subgroup

  16. Treatment of hepatocellular carcinoma by transarterial injection of anticancer agents in iodized oil suspension or of radioactive iodized oil solution

    International Nuclear Information System (INIS)

    Kobayashi, H.; Hidaka, H.; Kajiya, Y.; Tanoue, P.; Inoue, H.; Ikeda, K.; Nakajo, M.; Shinohara, S.

    1986-01-01

    Transarterial injection of modified iodized oil was performed in 48 patients with hepatoma. In 41 cases an adriamycin and/or mitomycin C-iodized oil suspension was administered into the proper hepatic artery or peripheral hepatic branches. A reduction in tumor size of over 50% was obtained in 14 of the 33 patients in whom CT examination was performed before and after treatment. Serum alpha-fetoprotein levels decreased in 20 of 21 cases within the first month after injection. The one-year survival rate was estimated at 55% in advanced hepatoma. In 7 patients, transarterial internal irradiation using radioactive iodized oil was carried out. A decrease in tumor size was observed in all cases and in alpha-fetoprotein levels in 6 cases. One patient with severe liver cirrhosis died in hepatorenal failure. No severe complications or other adverse reactions were encountered with either of the methods. (orig.)

  17. First Results from The GlueX Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Curtis [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    2016-05-01

    The GlueX experiment at Jefferson Lab ran with its first commissioning beam in late 2014 and the spring of 2015. Data were collected on both plastic and liquid hydrogen targets, and much of the detector has been commissioned. All of the detector systems are now performing at or near design specifications and events are being fully reconstructed, including exclusive production of pi^0, eta and omega mesons. Linearly-polarized photons were successfully produced through coherent bremsstrahlung and polarization transfer to the ρ has been observed.

  18. Effect of Wheat Straw Pretreatments and Glue Formulations on particle board properties

    International Nuclear Information System (INIS)

    Jabeen, S.; Naveed, S.; Yousaf, S.; Ramzan, N.

    2014-01-01

    In this paper, the effect of wheat straw (WS) pretreatments and glue formulations on mechanical (i.e. Compressive Strength (CS) and Impact Strength (IS)) and water resistance properties (i.e. Thickness Swelling (TS) and water absorption (WA)) of particle board have been investigated and the results have been compared with conventional wooden particleboard. Wheat straw was treated with steam available at 110 degree C and 20 psig, for the retention time of 5, 10 and 15 min. The solution of 10% HCl was also used for removing the lignin. Particleboard was prepared by bonding treated WS with four types of glue recipes of synthetic and natural binders like urea formaldehyde (UF), polyvinyl acetate (PVA), corn flour (CF) and wheat flour (WF). The particle board was formed at the hydraulic pressure and temperature of 2800 psig and 80 degree C respectively. It was observed that WS particleboard has low mechanical strength and high water resistance in comparison with conventional board. The particle board prepared with HCl cured wheat straw and glue having high urea formaldehyde and corn flour has higher CS and IS as well as low TS and WA. It may be concluded that wheat straw is a good substitute of wood for particle board while using HCl as a modifying chemical and strong binders like urea formaldehyde and corn flour. (author)

  19. Contribution of glue layer into epidermis sample fluorescence dynamics

    Science.gov (United States)

    Salomatina, Elena V.; Chernova, Svetlana P.; Pravdin, Alexander B.

    2000-04-01

    In this work, the temporal behavior of autofluorescence of epidermis samples under UV-irradiation has ben studied. The samples were prepared using surface epidermis stripping technique. Fluorescence spectra and kinetic curves of fluorescence intensity have been obtained. It has been concluded that the glue composition used allows the measurement of epidermis fluorescence dynamics with the first 60 min of experiment.

  20. Clinical and morphological evaluation of snake venom derived fibrin glue on the tendon healing in dogs

    Directory of Open Access Journals (Sweden)

    G. C. Ferraro

    2005-12-01

    Full Text Available The aim of this study was to evaluate the effect of snake venom derived fibrin glue on the healing of the deep digital flexor tendon, during three periods. The tendon of the 2nd digit of 30 thoracic limbs of dogs was partially sectioned for glue application. Biopsies were performed 7, 15, and 30 days post surgery for the clinical and morphological study of tendons. Analysis of the results showed that 73.3% of the tendons showed stump retraction and 16.6% moderate to excessive adherence, which affected sliding. There was a significant difference in the number of inflammatory cells among the three studied periods, being the highest on day 15. The morphological analysis revealed a typical tendon healing process with a lower level of inflammation in the acute phase, facilitating the cicatricial maturation phase. Snake venom derived fibrin glue promotes the healing in dog flexor tendon.

  1. Development of Silicon Photomultipliers and their Applications to GlueX Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Elton S. [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-07-01

    The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 x1.2 cm2) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

  2. Development of silicon photomultipliers and their applications to GlueX calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Elton S., E-mail: elton@jlab.org [Jefferson Lab, Newport News, VA 23606 (United States)

    2016-07-07

    The GlueX experiment is a photoproduction experiment in Hall D at Jefferson Lab that is being commissioned for use with the new 12 GeV accelerator. The purpose of the experiment is to search for Hybrid mesons, which are mesons with quark and gluon degrees of freedom. The barrel calorimeter of GlueX is instrumented with 4000 large-area (1.2 × 1.2 cm{sup 2}) silicon photomultipliers (SiPMs). These photon sensors have properties similar to vacuum photomultipliers, but are unaffected by high magnetic fields. In our experiment they operate in magnetic fields exceeding 1T. After extensive tests with a variety of sensors, we chose the S12045(X) custom SiPM arrays manufactured by Hamamatsu Corporation, also known as multi-pixel photon counters (MPPCs). We will give an overview of this new technology as well as the experience gained during two commissioning periods with beam.

  3. Generalized likelihood uncertainty estimation (GLUE) using adaptive Markov chain Monte Carlo sampling

    DEFF Research Database (Denmark)

    Blasone, Roberta-Serena; Vrugt, Jasper A.; Madsen, Henrik

    2008-01-01

    propose an alternative strategy to determine the value of the cutoff threshold based on the appropriate coverage of the resulting uncertainty bounds. We demonstrate the superiority of this revised GLUE method with three different conceptual watershed models of increasing complexity, using both synthetic......In the last few decades hydrologists have made tremendous progress in using dynamic simulation models for the analysis and understanding of hydrologic systems. However, predictions with these models are often deterministic and as such they focus on the most probable forecast, without an explicit...... of applications. However, the MC based sampling strategy of the prior parameter space typically utilized in GLUE is not particularly efficient in finding behavioral simulations. This becomes especially problematic for high-dimensional parameter estimation problems, and in the case of complex simulation models...

  4. Use of fibrin glue in the management of recurrent pterygium by conjunctival autograft

    International Nuclear Information System (INIS)

    Virendra K. Malik; Sandeep Kumar

    2010-01-01

    To evaluate whether use of fibrin glue instead of sutures for the treatment of recurrent pterygium with conjunctival auto-graft (CAG) further decreases its recurrence. A prospective, clinical open trial of 50 eyes of 50 patients with recurrent pterygium, who were randomly assigned to either, pterygium excision and CAG with fibrin glue (Group 1) or with 6 interrupted sutures (Group 2), was carried out from January 2009 to July 2010 at the outpatient department of Subharti Medical College, Meerut, North India. Both groups had 25 patients each. The groups were compared with regards to the surgical time taken, development of recurrence, postoperative symptoms (irritation, watering, and redness), and complications. Recurrence was seen in one (4%) eye in group I, and 3 (12%) eyes in group II after 9-13 months of follow up. The difference between the 2 groups was not statistically significant. The surgical time was significantly reduced, and postoperative inflammation and complications were less in group I. Postoperative symptoms were significantly more in group II patients. While conjunctival autograft with sutures for management of recurrent pterygium appears to be a safe and feasible modality, fibrin glue fixation of the autograft is a more viable option in terms of surgical ease, less time consuming, less postoperative complications, and less recurrence (Author).

  5. A general contact mechanical formulation of multilayered structures and its application to deconvolute thickness/mechanical properties of glue used in surface force apparatus.

    Science.gov (United States)

    Math, Souvik; Horn, Roger; Jayaram, Vikram; Biswas, Sanjay Kumar

    2007-04-15

    Currently data obtained from surface force apparatus experiments are convoluted with the mechanical response of glue of unknown thickness, used to bond mica sheets to the substrates. This paper describes a formulation to precisely deconvolute out the forces between the mica sheets by determining the thickness of glue, knowing the mechanical properties of the glue. The formulation consists of a general solution based on the noniterative Hankel transform of the Laplace equation. The generality is achieved by treating all the layers except the one in contact as an effective lumped system consisting of a set of springs in series, where each spring represents a layer. The solution is validated by nanoindentation of trilayer systems consisting of layers with widely diverse mechanical properties, some differing from each other by three orders of magnitude. SFA experiments are done with carefully metered slabs of glue. The proposed method is validated by comparing the actual glue thicknesses with those determined using the present analysis.

  6. Application of fibrin glue with bandage contact lens in pterygium surgery

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2014-05-01

    Full Text Available AIM: To explore the efficacy of fibrin glue with bandage contact lens for pain relief after pterygium surgery performed with limbal autograft transplantation.METHODS: A prospective clinical trial was carried out in 52 patients(72 eyesoperated for primary nasal pterygium. All patients were randomly divided into the fibrin glue with bandage contact lens group(experimental group, 28 cases, 38 eyesand suture group(control group, 24 cases, 34 eyes. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 20g/L lidocaine. In experimental group, the transplant was attached to the sclera with fibrin tissue adhesive and in control group with 10-0 Virgin silk sutures. Experimental group weared bandage contact lens after surgery while the control group did not. The degree of pain after surgery was evaluated at 1, 2, 3, 5 and 7d after surgery. Follow-up was 6mo, matching degree of graft and complication such as infection, relapse, implant healing badness and subconjunctival cyst were mainly observed and recorded.RESULTS: The pain index scores of the experimental group were significantly less than those of control group(all P=0.000. In observation period, all conjunctival autografts in both groups were successfully attached and were intact without falling off, dissolution or recurrence and there were no complications such as infection, relapse, implant healing badness and subconjunctival cyst.CONCLUSION: Fibrin glue with bandage contact lens could significantly release pain response afterpterygium excision surgery.

  7. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    CERN Document Server

    INSPIRE-00407830; Bloch, Ingo; Edwards, Sam; Friedrich, Conrad; Gregor, Ingrid M.; Jones, T; Lacker, Heiko; Pyatt, Simon; Rehnisch, Laura; Sperlich, Dennis; Wilson, John

    2016-05-24

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). This glue has several disadvantages, which motivated the search for an alternative. This paper presents a study concerning the use of six ultra-violet (UV) cure glues and a glue pad for use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, the thermal conduction and shear strength, thermal cycling, radiation hardness, corrosion resistance and shear strength tests. These investigatio...

  8. Re: Fibrin Glue Injections: A Minimally Invasive and Cost-Effective Treatment for Post-Renal Transplant Lymphoceles and Lymph Fistulas

    Directory of Open Access Journals (Sweden)

    Presser N

    2016-03-01

    Full Text Available In this retrospective study, 46 (2.7% patients out of 1662 kidney transplant recipients had developed symptomatic lymphocele/lymph fistula requiring intervention over an 11-year period. Open surgical drainage (22, laparoscopic surgical drainage (11 and percutaneous fibrin glue injections into the drained lymphocele cavity (13 were used to treat this complication. Besides being effective both on the early and late developed lymphoceles, significantly lower recurrence rates by fibrin glue injections and lower median treatment costs were observed when compared with the other two surgical modalities. It has also the advantage of an outpatient procedure that can be performed using fluoroscopic guidance, under local anesthesia. However, due to era effect, most of the open and laparoscopic surgical recipients were treated with sirolimus, a well-known antiproliferative immunosuppressive agent, which can promote development of lymphoceles and surgical failure. However, the majority of fibrin glue-treated cases were with tacrolimus-based regimens, but this study, in its nature, is far from giving the answer for decreased number of recurrences with fibrin glue

  9. Percutaneous Glue Embolization of a Visceral Artery Pseudoaneurysm in a Case of Sickle Cell Anemia

    International Nuclear Information System (INIS)

    Gulati, Gurpreet S.; Gulati, Manpreet S.; Makharia, Govind; Hatimota, Pradeep; Saikia, Nripen; Paul, Shashi B.; Acharya, Subrat

    2006-01-01

    Although aneurysmal complications of sickle cell anemia have been described in the intracranial circulation, visceral artery pseudoaneurysms in this disease entity have not previously been reported in the literature. Conventional treatment of visceral pseudoaneurysms has been surgical ligation or resection of the aneurysm. Transcatheter embolization has emerged as an attractive, minimally invasive alternative to surgery in the treatment of these lesions. In certain situations, however, due to the unfavorable angiographic anatomy precluding safe transcatheter embolization, direct percutaneous glue injection of the pseudoaneurysm sac may be considered to achieve successful occlusion of the sac. The procedure may be rendered safer by simultaneous balloon protection of the parent artery. We describe this novel treatment modality in a case of inferior pancreaticoduodenal artery pseudoaneurysm in a patient with sickle cell anemia. Although a complication in the form of glue reflux into the parent vessel occurred that necessitated surgery, this treatment modality may be used in very selected cases (where conventional endovascular embolization techniques are not applicable) after careful selection of the balloon diameter and appropriate concentration of the glue-lipiodol mixture

  10. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Frank, Michael, E-mail: michael.frank@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Pellerin, Olivier, E-mail: olivier@pellerin.as; Primio, Massimiliano Di, E-mail: massimiliano.di.primio@gmail.com; Angelopoulos, Georgios, E-mail: giorginos78@msn.com [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Boughenou, Marie-Fazia, E-mail: marie-fazia.boughenou@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Anesthesia and Surgical Intensive Care Unit (France); Pagny, Jean-Yves, E-mail: jean-yves.pagny@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France); Messas, Emmanuel, E-mail: emmanuel.messas@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Rare Vascular Diseases Reference Center (France); Sapoval, Marc, E-mail: marc.sapoval2@egp.aphp.fr [Assistance Publique des Hôpitaux de Paris, Georges Pompidou European Hospital, Interventional Radiology Department (France)

    2013-05-09

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture.

  11. Embolization of Life-Threatening Arterial Rupture in Patients with Vascular Ehlers–Danlos Syndrome

    International Nuclear Information System (INIS)

    Okada, Takuya; Frank, Michael; Pellerin, Olivier; Primio, Massimiliano Di; Angelopoulos, Georgios; Boughenou, Marie-Fazia; Pagny, Jean-Yves; Messas, Emmanuel; Sapoval, Marc

    2014-01-01

    PurposeTo evaluate the safety and efficacy of transarterial embolization of life-threatening arterial rupture in patients with vascular Ehlers–Danlos syndrome (vEDS) in a single tertiary referral center.MethodsWe retrospectively analyzed transarterial embolization for vEDS performed at our institution from 2000 to 2012. The indication of embolization was spontaneous arterial rupture or pseudoaneurysm with acute bleeding. All interventions used a percutaneous approach through a 5F or less introducer sheath. Embolic agents were microcoils and glue in 3 procedures, glue alone in 2, and microcoils alone in 2.ResultsFive consecutive vEDS patients were treated by 7 embolization procedures (4 women, mean age 29.8 years). All procedures were successfully performed. Two patients required a second procedure for newly arterial lesions at a different site from the first procedure. Four of the five patients were still alive after a mean follow-up of 19.4 (range 1–74.7) months. One patient died of multiple organ failure 2 days after procedure. Minor procedural complications were observed in 3 procedures (43 %), all directly managed during the same session. Remote arterial lesions occurred after 3 procedures (43 %); one underwent a second embolization, and the other 2 were observed conservatively. Puncture site complication was observed in only one procedure (14 %).ConclusionEmbolization for vEDS is a safe and effective method to manage life-threatening arterial rupture

  12. Versatile fabrication of paper-based microfluidic devices with high chemical resistance using scholar glue and magnetic masks.

    Science.gov (United States)

    Cardoso, Thiago M G; de Souza, Fabrício R; Garcia, Paulo T; Rabelo, Denilson; Henry, Charles S; Coltro, Wendell K T

    2017-06-29

    Simple methods have been developed for fabricating microfluidic paper-based analytical devices (μPADs) but few of these devices can be used with organic solvents and/or aqueous solutions containing surfactants. This study describes a simple fabrication strategy for μPADs that uses readily available scholar glue to create the hydrophobic flow barriers that are resistant to surfactants and organic solvents. Microfluidic structures were defined by magnetic masks designed with either neodymium magnets or magnetic sheets to define the patter, and structures were created by spraying an aqueous solution of glue on the paper surface. The glue-coated paper was then exposed to UV/Vis light for cross-linking to maximize chemical resistance. Examples of microzone arrays and microfluidic devices are demonstrated. μPADs fabricated with scholar glue retained their barriers when used with surfactants, organic solvents, and strong/weak acids and bases unlike common wax-printed barriers. Paper microzones and microfluidic devices were successfully used for colorimetric assays of clinically relevant analytes commonly detected in urinalysis to demonstrate the low background of the barrier material and generally applicability to sensing. The proposed fabrication method is attractive for both its ability to be used with diverse chemistries and the low cost and simplicity of the materials and process. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    Science.gov (United States)

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  14. Transarterial chemoembolization with drug-eluting beads in hepatocellular carcinoma

    Science.gov (United States)

    Nam, Hee Chul; Jang, Bohyun; Song, Myeong Jun

    2016-01-01

    Transarterial chemoembolization (TACE) is a widely used standard treatment for patients with hepatocellular carcinoma (HCC) who are not suitable candidates for curative treatments. The rationale for TACE is that intra-arterial chemotherapy using lipiodol and chemotherapeutic agents, followed by selective vascular embolization, results in a strong cytotoxic effect as well as ischemia (conventional TACE). Recently, drug-eluting beads (DC Beads®) have been developed for transcatheter treatment of HCC to deliver higher doses of the chemotherapeutic agent and to prolong contact time with the tumor. DC Beads® can actively sequester doxorubicin hydrochloride from solution and release it in a controlled sustained fashion. Treatment with DC Beads® substantially reduced the amount of chemotherapeutic agent that reached the systemic circulation compared with conventional, lipiodol-based regimens, significantly reducing drug-related adverse events. In this article, we describe the treatment response, survival, and safety of TACE used with drug-eluting beads for the treatment of HCC and discuss future therapeutic possibilities. PMID:27833376

  15. Characterisation of a new bioadhesive system based on polysaccharides with the potential to be used as bone glue.

    Science.gov (United States)

    Hoffmann, Bettina; Volkmer, Elias; Kokott, Andreas; Augat, Peter; Ohnmacht, Michael; Sedlmayr, Nicole; Schieker, Matthias; Claes, Lutz; Mutschler, Wolf; Ziegler, Günter

    2009-10-01

    Although gluing bone is in theory a very attractive alternative to classical fracture treatment, this method is not yet clinically established due to the lack of an adhesive which would meet all the necessary requirements. We therefore developed a novel two-component bioadhesive system with the potential to be used as a bone adhesive based on biocompatible and degradable biopolymers (chitosan, oxidised dextran or starch). After mixing in water, the two components covalently cross-link by forming a Schiff's base. By the same mechanism, the glue binds to any other exposed amino group such as for example those exposed in fractured bone, even in the presence of water. Modified chitosan was synthesised from commercially available chitosan by deacetylation and was then reduced in molecular weight by heating in acid. The amount of free amino groups was analysed by IR. The molecular weight was determined by viscosimetry. Starch or dextran were oxidised with periodic acid to generate aldehyde groups, which were quantified by titration. l-Dopa was conjugated to oxidised dextran or starch in analogy to the gluing mechanism of mussels. Biomechanical studies revealed that the new glue is superior to fibrin glue, but has less adhesive strength than cyanoacrylates. In vitro cell testing demonstrated excellent biocompatibility, rendering this glue a potential candidate for clinical use.

  16. Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue.

    Science.gov (United States)

    Martinelli, L; Graffigna, A; Guarnerio, M; Bonmassari, R; Disertori, M

    2000-11-01

    Severe stenosis of right and left main coronary artery ostia developed after aortic root reconstruction with gelatin-resorcin-formol glue for correction of acute type A aortic dissection. Surgical treatment of this condition required grafting of the right and left anterior descending arteries with bilateral mammary arteries on the beating heart.

  17. The impact and adoption of GLUE 2.0 in the LCG/EGEE production Grid

    International Nuclear Information System (INIS)

    Burke, Stephen; Andreozzi, Sergio; Donno, Flavia; Ehm, Felix; Field, Laurence; Litmaath, Maarten; Millar, Paul

    2010-01-01

    The GLUE information schema has been in use in the LCG/EGEE production Grid since the first version was defined in 2002. In 2007 a major redesign of GLUE, version 2.0, was started in the context of the Open Grid Forum following the creation of the GLUE Working Group. This process has taken input from a number of Grid projects, but as a major user of the version 1 schema LCG/EGEE has had a strong interest that the new schema should support its needs. In this paper we discuss the structure of the new schema in the light of the LCG/EGEE requirements and explain how they are met, and where improvements have been achieved compared with the version 1 schema. In particular we consider some difficulties encountered in recent extensions of the use of the version 1 schema to aid resource accounting in LCG, to enable the use of the SRM version 2 storage protocol by the LHC experiments, and to publish information about a wider range of services to improve service discovery. We describe how these can be better met by the new schema, and we also discuss the way in which the transition to the new schema is being managed.

  18. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore)

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  19. Comparison of mechanical compressive properties of commercial and autologous fibrin glues for tissue engineering applications.

    Science.gov (United States)

    Cravens, Matthew G; Behn, Anthony W; Dragoo, Jason L

    2017-11-01

    Fibrin glues are widely used in orthopedic surgery as adhesives and hemostatic agents. We evaluated the compressive properties of selected fibrin glues in order to identify which are appropriate for tissue regeneration applications subject to compression. Uniaxial unconfined compression tests were performed on fibrin gels prepared from commercial and autologous products: (1) Evicel (Ethicon), (2) Tisseel (Baxter), (3) Angel (Arthrex), and (4) ProPlaz (Biorich). Cyclic loads were applied from 0 to 30% strain for 100cycles at 0.5Hz. Following cyclic testing, specimens were subjected to ramp displacement of 1% strain per second to 80% strain. Throughout cyclic loading, Evicel and Tisseel deformed (shortened) less than Angel at all but one time point, and deformed less than ProPlaz at cycles 10 and 20. The dynamic moduli, peak stress, and strain energy were significantly greater in Tisseel than all other groups. Evicel displayed significantly greater dynamic moduli, peak stress, and strain energy than Angel and ProPlaz. Following cyclic testing, Tisseel and Evicel were significantly less deformed than Angel. No specimens exhibited gross failure during ramp loading to 80% strain. Ramp loading trends mirrored those of cyclic loading. The tested commercial glues were significantly more resistant to compression than the autologous products. The compressive properties of Tisseel were approximately twice those of Evicel. All preparations displayed moduli multiple orders of magnitude less than that of native articular cartilage. We conclude that in knee surgeries requiring fibrin glue to undergo compression of daily activity, commercial products are preferable to autologous preparations from platelet-poor plasma, though both will deform significantly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Efficacy and Safety of Transarterial Radioembolization Versus Chemoembolization in Patients With Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Moreno-Luna, Laura E.; Yang, Ju Dong; Sanchez, William; Paz-Fumagalli, Ricardo; Harnois, Denise M.; Mettler, Teresa A.; Gansen, Denise N.; Groen, Piet C. de; Lazaridis, Konstantinos N.; Narayanan Menon, K. V.; LaRusso, Nicholas F.; Alberts, Steven R.; Gores, Gregory J.; Fleming, Chad J.; Slettedahl, Seth W.; Harmsen, William S.; Therneau, Terry M.; Wiseman, Gregory A.; Andrews, James C.; Roberts, Lewis R.

    2013-01-01

    Purpose. Intermediate-stage hepatocellular carcinoma (HCC) is usually treated with locoregional therapy using transarterial chemoembolization (TACE). Transarterial radioembolization (TARE) using β-emitting yttrium-90 integral to the glass matrix of the microspheres is an alternative to TACE. This retrospective case-control study compared the outcomes and safety of TARE versus TACE in patients with unresectable HCC. Materials and Methods. Patients with unresectable HCC without portal vein thrombosis treated with TARE between 2005 and 2008 (n = 61) were retrospectively frequency-matched by age, sex, and liver dysfunction with TACE-treated patients (n = 55) in the Mayo Clinic Hepatobiliary Neoplasia Registry. Imaging studies were reviewed, and clinical and safety outcomes were abstracted from the medical records. Results. Complete tumor response was more common after TARE (12 %) than after TACE (4 %) (p = 0.17). When complete response was combined with partial response and stable disease, there was no difference between TARE and TACE. Median survival did not differ between the two groups (15.0 months for TARE and 14.4 months for TACE; p = 0.47). Two-year survival rates were 30 % for TARE and 24 % for TACE. TARE patients received fewer treatments (p < 0.001). Fifty-nine (97 %) TARE patients received outpatient treatment. In contrast, 53 (98 %) TACE patients were hospitalized for ≥1 day (p < 0.001). Compared with TACE, TARE was more likely to induce fatigue (p = 0.003) but less likely to cause fever (p = 0.02). Conclusion. There was no significant difference in efficacy between TARE and TACE. TARE patients reported more fatigue but had less fever than TACE patients. Treatment with TARE required less hospitalization than treatment with TACE. These findings require confirmation in randomized trials.

  1. A direct biocombinatorial strategy toward next generation, mussel-glue inspired saltwater adhesives.

    Science.gov (United States)

    Wilke, Patrick; Helfricht, Nicolas; Mark, Andreas; Papastavrou, Georg; Faivre, Damien; Börner, Hans G

    2014-09-10

    Biological materials exhibit remarkable, purpose-adapted properties that provide a source of inspiration for designing new materials to meet the requirements of future applications. For instance, marine mussels are able to attach to a broad spectrum of hard surfaces under hostile conditions. Controlling wet-adhesion of synthetic macromolecules by analogue processes promises to strongly impact materials sciences by offering advanced coatings, adhesives, and glues. The de novo design of macromolecules to mimic complex aspects of mussel adhesion still constitutes a challenge. Phage display allows material scientists to design specifically interacting molecules with tailored affinity to material surfaces. Here, we report on the integration of enzymatic processing steps into phage display biopanning to expand the biocombinatorial procedure and enable the direct selection of enzymatically activable peptide adhesion domains. Adsorption isotherms and single molecule force spectroscopy show that those de novo peptides mimic complex aspects of bioadhesion, such as enzymatic activation (by tyrosinase), the switchability from weak to strong binders, and adsorption under hostile saltwater conditions. Furthermore, peptide-poly(ethylene oxide) conjugates are synthesized to generate protective coatings, which possess anti-fouling properties and suppress irreversible interactions with blood-plasma protein cocktails. The extended phage display procedure provides a generic way to non-natural peptide adhesion domains, which not only mimic nature but also improve biological sequence sections extractable from mussel-glue proteins. The de novo peptides manage to combine several tasks in a minimal 12-mer sequence and thus pave the way to overcome major challenges of technical wet glues.

  2. Endoluminal embolization of bilateral atherosclerotic common iliac aneurysms with fibrin tissue glue (Beriplast)

    International Nuclear Information System (INIS)

    Beese, Richard C.; Tomlinson, Mark A.; Buckenham, Timothy M.

    2000-01-01

    The standard surgical approach to nonleaking iliac aneurysms found at repair of a leaking abdominal aortic aneurysm is to minimize the operative risk by repairing the abdominal aorta only. This means that the bypassed iliac aneurysms may have to be repaired later. As this population of patients are usually elderly with coexisting medical problems, interventional radiology is being used to embolize these aneurysms, thus avoiding the morbidity and mortality associated with further general anesthesia and surgery. Various materials and stents have been reported to be effective in the treatment of iliac aneurysms. We report the successful use of endoluminal fibrin tissue glue (Beriplast) to treat two large iliac aneurysms in a patient who had had a previous abdominal aortic aneurysm repair. We discuss the technique involved and the reasons why we used tissue glue in this patient.

  3. Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments

    International Nuclear Information System (INIS)

    Baba, Seiki; Hoshino, Takeshi; Ito, Len; Kumasaka, Takashi

    2013-01-01

    A new crystal-mounting method has been developed that involves a combination of controlled humid air and polymer glue for crystal coating. This method is particularly useful when applied to fragile protein crystals that are known to be sensitive to subtle changes in their physicochemical environment. Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection

  4. Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Seiki; Hoshino, Takeshi; Ito, Len; Kumasaka, Takashi, E-mail: kumasaka@spring8.or.jp [Japan Synchrotron Radiation Research Institute (JASRI/SPring-8), 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2013-09-01

    A new crystal-mounting method has been developed that involves a combination of controlled humid air and polymer glue for crystal coating. This method is particularly useful when applied to fragile protein crystals that are known to be sensitive to subtle changes in their physicochemical environment. Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection.

  5. GLUE Based Uncertainty Estimation of Urban Drainage Modeling Using Weather Radar Precipitation Estimates

    DEFF Research Database (Denmark)

    Nielsen, Jesper Ellerbæk; Thorndahl, Søren Liedtke; Rasmussen, Michael R.

    2011-01-01

    Distributed weather radar precipitation measurements are used as rainfall input for an urban drainage model, to simulate the runoff from a small catchment of Denmark. It is demonstrated how the Generalized Likelihood Uncertainty Estimation (GLUE) methodology can be implemented and used to estimate...

  6. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation

    International Nuclear Information System (INIS)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman; Manhart, Michael

    2018-01-01

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. (orig.)

  7. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation

    Energy Technology Data Exchange (ETDEWEB)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Manhart, Michael [Imaging Concepts, HC AT IN IMC, Siemens Healthcare GmbH, Advanced Therapies, Innovation, Forchheim (Germany)

    2018-01-15

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. (orig.)

  8. Unenhanced and Contrast-Enhanced Ultrasonography During Hepatic Transarterial Embolization and Chemoembolization With Drug-Eluting Beads

    International Nuclear Information System (INIS)

    Moschouris, Hippocrates; Malagari, Katerina; Kornezos, Ioannis; Papadaki, Marina Georgiou; Gkoutzios, Panagiotis; Matsaidonis, Dimitrios

    2010-01-01

    The purpose of this study was to describe and evaluate the findings of unenhanced ultrasonography (US) and contrast-enhanced ultrasonography (CEUS) when these modalities are applied during transarterial embolization (TAE) or transarterial chemoembolization (TACE) of liver tumors. Sixteen tumors (9 hepatocellular carcinomas, 5 metastases from colorectal cancer, and 2 hemangiomas) were treated with TAE with microspheres and/or TACE with drug-eluting beads. All of these lesions were studied with intraprocedural unenhanced US and 12 were studied with intraprocedural CEUS. For the latter, a second-generation echo-enhancer (SonoVue; Bracco, Milan, Italy) and a low mechanical index technique were used. Intraprocedural findings were classified according to an arbitrary scale and were compared with pretreatment imaging (CEUS and computed tomography or CEUS and magnetic resonance imaging), with postembolization angiography, and with follow-up results. On unenhanced intraprocedural US, 13 of 16 tumors demonstrated intralesional high-level echoes of varying extent. These feature correlated poorly (r = 0.33, p = 0.097) with and generally underestimated the actual extent of necrosis. Exceptionally, high-level echoes that occupied the largest part of the treated lesions were associated with >50% tumor necrosis. Intraprocedural CEUS clearly depicted immediate partial or complete disappearance of tumor enhancement as a result of TAE/TACE. Three of 6 tumors with complete devascularization on postembolization angiogram showed residual enhancement on intraprocedural CEUS. Intraprocedural CEUS findings correlated closely (r = 0.91, p = 0.002) with follow-up findings. Intraprocedural sonography, particularly with echo-enhancers, could be used for intraprocedural monitoring in selected cases of liver tumors that undergo TAE or TACE.

  9. Repetitive transarterial chemoembolization (TACE) of liver metastases from gastric cancer: Local control and survival results

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J., E-mail: T.Vogl@em.uni-frankfurt.de [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt (Germany); Gruber-Rouh, Tatjana; Eichler, Katrin [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt (Germany); Nour-Eldin, Nour-Eldin A. [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt (Germany); Department of Radiology, Faculty of Medicine, Cairo University, Cairo (Egypt); Trojan, Jörg [Department of Internal Medicine I, Johann Wolfgang Goethe-University Frankfurt (Germany); Zangos, Stephan [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt (Germany); Naguib, Nagy N.N. [Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University Frankfurt (Germany); Radiology Department, Faculty of Medicine, Alexandria University, Alexandria (Egypt)

    2013-02-15

    Objective: To evaluate the local tumor control and survival data after transarterial chemoembolization with different drug combinations in the palliative treatment of patients with liver metastases of gastric cancer. Materials and methods: The study was retrospectively performed. 56 patients (mean age, 52.4) with unresectable liver metastases of gastric cancer who did not respond to systemic chemotherapy were repeatedly treated with TACE in 4-week intervals. In total, 310 chemoembolization procedures were performed (mean, 5.5 sessions per patient). The local chemotherapy protocol consisted of mitomycin alone (30.4%), mitomycin and gemcitabine (33.9%), or mitomycin, gemcitabine and cisplatin (35.7%). Embolization was performed with lipiodol and starch microspheres. Local tumor response was evaluated by MRI according to RECIST. Survival data from first chemoembolization were calculated according to the Kaplan–Meier method. Results: The local tumor control was: complete response in 1.8% (n = 1), partial response in 1.8% (n = 1), stable disease in 51.8% (n = 29) and progressive disease in 44.6% (n = 25) of patients. The 1-, 2-, and 3-year survival rate from the start of chemoembolization were 58%, 38%, and 23% respectively. The median and mean survival times were 13 and 27.1 months. A Statistically significant difference between patients treated with different chemotherapy protocols was noted (ρ = 0.045) with the best survival time in the mitomycin, gemcitabine and cisplatin group. Conclusion: Transarterial chemoembolization is a minimally invasive therapy option for palliative treatment of liver metastases in patients with gastric cancer.

  10. Management of an extrasphincteric fistula in an HIV-positive patient by using fibrin glue: a case report with tips and tricks

    Directory of Open Access Journals (Sweden)

    Sapalidis Konstantinos

    2010-02-01

    Full Text Available Abstract Background Individuals with impaired immunity are at higher risk of perianal diseases. Concerning complex anal fistulas impaired healing and complication rates are also higher. Definitive treatment of a fistula aims controlling the purulent discharge and prevents its recurrence. It depends mainly on the trajectory of the fistula and the underlying disease. We present a case of a HIV-positive patient with a complex extrasphincteric anal fistula who was treated successfully with fibrin glue application. We further, discuss tips and tricks when applying fibrin glue as plugging material in complex anal fistulas. Case presentation A sixty-one-year-old HIV-positive male referred to us for warts and extrasphincteric fistula. Because of the patients' immunological status, we opted against surgery and recommended fibrin glue plugging. The patient was discharged the same day. A follow-up examination was performed 5 days after the initial fibrin glue application showing that the fistula canal was obstructed. Three months and a year post-intervention the fistula tract remains closed. Conclusion The best treatment for a disease gives at least the same result with the other treatments with minimised risk for the life of the patient and minimal application effort. Conservative closure of fistula with fibrin plugging is simple, safe and with less morbidity than surgery. Our patient was successfully treated without endangering his life despite his precarious medical state. Not everybody believes in the effectiveness of fibrin glue application, however we consider this solution in cases of complex fistulas at least as primary procedure in special populations such as the immunosupressed.

  11. [The advantages in using cyanoacrylate glue over skin staples as a method of skin graft fixation in the pediatric burns population].

    Science.gov (United States)

    Curings, P; Vincent, P-L; Viard, R; Gir, P; Comparin, J-P; Voulliaume, D

    2017-11-23

    Local postoperative care and burn wound management can present with a certain degree of difficulty in the pediatric population. While the use of skin staples as a method of skin graft fixation is a well-known, rapid and simple method, their removal can be painful and may necessitate some sedation or even general anesthesia. We studied in this article the advantages and economic value of using the cyanoacrylate glue as a fixation method for skin grafts. A comparative study was carried out from 2012 to 2016. Hundred and eighteen infants with burns up to 5% of total body surface area were included in the study. Seventy-two infants had split thickness skin grafts fixed with skin staples. Forty-six infants had split thickness skin grafts fixed with cyanoacrylate glue. We compared the quality of graft, the sedation used during the first postoperative dressing, the length of hospital stay, the amount of glue used and the presence of complications. There is a difference between the two groups studied in terms of age and total burn surface area. The rate of graft take was 100% in both groups. The first postoperative dressing was carried out without the use of powerful analgesia in the cyanoacrylate group, while it was necessary to use general anesthesia in 64% of the skin staples group. The average length of stay in hospital after skin grafting was 4.9 days for the cyanoacrylate glue versus 6.5 days in the skin staples group. No complications were noted in the 2 groups. The use of cyanoacrylate glue allows rapid fixation of skin grafts and avoid general anesthesia for postoperative cares. Subsequently the length of hospital stay is reduced within 25%. The medico-economic value of glue protocol is highly significant compared to skin staples, while having similar good results and without significant problems. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  12. Management of nontraumatic corneal perforation with tectonic drape patch and cyanoacrylate glue.

    Science.gov (United States)

    Khalifa, Yousuf M; Bailony, M Rami; Bloomer, Michele M; Killingsworth, Daniel; Jeng, Bennie H

    2010-10-01

    To report a case of nontraumatic corneal perforation managed with a tectonic drape patch. Interventional case report. A 60-year-old patient with a corneal scar in his left eye likely secondary to herpes simplex virus interstitial keratitis underwent laser peripheral iridotomy for narrow angles. He developed progressive thinning of the cornea overlying the scar that led to a descemetocele and then ultimately a 1.2- × 1.7-mm perforation. Intraoperatively, several attempts were made to seal the perforation with cyanoacrylate glue, but the wound continued to leak. Sterile plastic drape that was on the surgical field was fashioned into a 2-mm-diameter patch, and the peripheral edge of the tectonic drape patch was glued over the perforation, successfully sealing the cornea. One week later, the drape patch was intact without leak, and a penetrating keratoplasty was carried out without complication. Tectonic drape patch technique for nontraumatic corneal perforations in which there is tissue loss is a viable temporizing option when cyanoacrylate glue alone fails and when there is no corneal tissue or amniotic membrane available to close the wound.

  13. Percutaneous sclerotherapy of sialoceles after parotidectomy with fibrin glue, OK-432, and bleomycin.

    Science.gov (United States)

    Chen, Wei-liang; Zhang, Li-ping; Huang, Zhi-quan; Zhou, Bin

    2013-12-01

    We evaluated the curative effect of fibrin glue combined with OK-432 (streptococcal pyrogenic exotoxin A, Picibanil™) and bleomycin on 9 patients with sialoceles after parotidectomy. The primary lesions included pleomorphic adenomas in 6 cases and Warthin's tumours in 3 cases. After a sialocele had been diagnosed each patient had repeated aspirations and pressure dressings for 3-4 weeks, but these treatments failed. The patients were then treated with percutaneous sclerotherapy with the injection of fibrin glue 8-10 ml combined with OK-432 5 mg and bleomycin 15 mg. All the sialoceles disappeared completely after a single procedure in 2-3 weeks. The patients have been followed up for more than 6 months with no evidence of recurrent sialocele or injury to the facial nerve related to sclerotherapy. This simple, safe technique can be successfully used to treat sialoceles after parotidectomy. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Intraoperative use of fibrin glue dyed with methylene blue in surgery for branchial cleft anomalies.

    Science.gov (United States)

    Piccioni, Michela; Bottazzoli, Marco; Nassif, Nader; Stefini, Stefania; Nicolai, Piero

    2016-09-01

    We present a new method of optimizing the results of surgery for branchial cleft anomalies based on the intraoperative injection of fibrin glue combined with methylene blue dye. Retrospective single-center cohort study. The method was applied in 17 patients suffering from branchial anomalies. Six (35.29%) had a preauricular lesion; three (17.65%) had lesions derived from the first arch/pouch/groove (type I), four (23.53%) had lesions derived from the first (type II), one (5.88%) had lesions derived from the second, one (5.88%) had lesions derived from the third, and two (11.76%) had lesions derived from the fourth. The median and mean age at surgery were 10 and 10.6 years, respectively. All patients were followed by periodic clinical and ultrasonographic examination. The combination of fibrin glue with methylene blue facilitated the correct assessment of the extension of the lesions and their intraoperative manipulation. After a mean follow-up of 47.8 months, all patients were free of disease. Intraoperative injection of branchial fistulae and cysts by a mixture of fibrin glue and methylene blue is an effective, easy, and safe tool to track lesions and achieve radical resection. The technique requires a definitive validation on a large cohort with adequate stratification of patients. 4 Laryngoscope, 126:2147-2150, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  15. Transarterial embolization treatment for aberrant systemic arterial supply to the normal lung: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bo Ra; Jo, Jeong Hyun; Park, Byeong Ho [Dept. of Radiology, Dong A University Hospital, Dong A University College of Medicine, Busan (Korea, Republic of)

    2017-06-15

    A 24-year-old man presented with dyspnea on exertion and intermittent blood-tinged sputum. He was diagnosed with aberrant systemic arterial supply to the normal lung (ASANL) based on the results of imaging studies. The patient was successfully treated with transarterial embolization using coils and a vascular plug and his symptoms disappeared during the follow-up. Herein, we reported the imaging findings of ASANL, differential diagnoses, and its treatment options. In addition, we reviewed the relevant literature.

  16. Comparação das técnicas transarterial e de estimulação de múltiplos nervos para bloqueio do plexo braquial por via axilar usando lidocaína com epinefrina

    OpenAIRE

    Imbelloni, Luiz Eduardo; Beato, Lúcia; Cordeiro, José Antônio

    2005-01-01

    JUSTIFICATIVA E OBJETIVOS: A técnica transarterial com grandes doses de anestésico local resulta em alta efetividade para o bloqueio axilar do plexo braquial. A técnica utilizando múltiplos estímulos exige mais tempo e maior experiência. Este estudo prospectivo compara a latência e o índice de sucesso do bloqueio do plexo braquial usando duas técnicas de localização: transarterial ou múltipla estimulação dos nervos. MÉTODO: A lidocaína com epinefrina, 800 mg, foi usada inicialmente para o blo...

  17. Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiai, Sodai, E-mail: hoshiai@sb4.so-net.ne.jp; Mori, Kensaku; Ishiguro, Toshitaka; Konishi, Takahiro; Uchikawa, Yoko [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan); Fukuda, Kuniaki [University of Tsukuba Hospital, Department of Gastroenterology (Japan); Minami, Manabu [University of Tsukuba Hospital, Department of Diagnostic and Interventional Radiology (Japan)

    2017-04-15

    Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

  18. The GlueX central drift chamber: Design and performance

    International Nuclear Information System (INIS)

    Van Haarlem, Y.; Meyer, C.A.; Barbosa, F.; Dey, B.; Lawrence, D.; Razmyslovich, V.; Smith, E.; Visser, G.; Whitlatch, T.; Wilkin, G.; Zihlmann, B.

    2010-01-01

    Tests and studies concerning the design and performance of the GlueX Central Drift Chamber (CDC) are presented. A full-scale prototype was built to test and steer the mechanical and electronic design. Small scale prototypes were constructed to test for sagging and to do timing and resolution studies of the detector. These studies were used to choose the gas mixture and to program a Monte Carlo simulation that can predict the detector response in an external magnetic field. Particle identification and charge division possibilities were also investigated.

  19. Uncertainty and sensitivity assessments of an agricultural-hydrological model (RZWQM2) using the GLUE method

    Science.gov (United States)

    Sun, Mei; Zhang, Xiaolin; Huo, Zailin; Feng, Shaoyuan; Huang, Guanhua; Mao, Xiaomin

    2016-03-01

    Quantitatively ascertaining and analyzing the effects of model uncertainty on model reliability is a focal point for agricultural-hydrological models due to more uncertainties of inputs and processes. In this study, the generalized likelihood uncertainty estimation (GLUE) method with Latin hypercube sampling (LHS) was used to evaluate the uncertainty of the RZWQM-DSSAT (RZWQM2) model outputs responses and the sensitivity of 25 parameters related to soil properties, nutrient transport and crop genetics. To avoid the one-sided risk of model prediction caused by using a single calibration criterion, the combined likelihood (CL) function integrated information concerning water, nitrogen, and crop production was introduced in GLUE analysis for the predictions of the following four model output responses: the total amount of water content (T-SWC) and the nitrate nitrogen (T-NIT) within the 1-m soil profile, the seed yields of waxy maize (Y-Maize) and winter wheat (Y-Wheat). In the process of evaluating RZWQM2, measurements and meteorological data were obtained from a field experiment that involved a winter wheat and waxy maize crop rotation system conducted from 2003 to 2004 in southern Beijing. The calibration and validation results indicated that RZWQM2 model can be used to simulate the crop growth and water-nitrogen migration and transformation in wheat-maize crop rotation planting system. The results of uncertainty analysis using of GLUE method showed T-NIT was sensitive to parameters relative to nitrification coefficient, maize growth characteristics on seedling period, wheat vernalization period, and wheat photoperiod. Parameters on soil saturated hydraulic conductivity, nitrogen nitrification and denitrification, and urea hydrolysis played an important role in crop yield component. The prediction errors for RZWQM2 outputs with CL function were relatively lower and uniform compared with other likelihood functions composed of individual calibration criterion. This

  20. The Analysis of the Causes of Prolonged Hospitalization after Transarterial Chemoembolization in Patients with Unresectable Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Chang, Nam Kyu; Jeong, Yong Yeon; Park, Seo Yeon; Kim, Jae Kyu

    2011-01-01

    We wanted to analyze the causes of prolonged hospitalization (over 7 days) after transarterial chemoembolization (TACE) in patients with unresectable Hepatocellular Carcinoma and its related factors. We analyzed the total hospital days after patients with unresectable Hepatocellular Carcinoma received transarterial chemoembolization, and these patients were treated during the recent 6 month at our hospital. Two hundred twenty three sessions showed a short term hospital stay (less than 7 days) and 57 sessions showed a prolonged hospital stay (more than 7 days), so a total of 280 sessions were analyzed. The hospital stay less than seven days was set for the control group and this was correlated with the patient's age, gender, the level of bilirubin and albumin, the platelet counts, the AST/ALT ratio, the a-FT, the presence of portal vein thrombosis and ascites, several scoring systems (Child-Pugh, CLIP, and OKUDA score) and the need for additional embolization at the time of the procedure. Compared with that of the control group, ascites (p=0.004), portal vein thrombosis (p=0.000), a platelet count below the hundred thousand (p=0.012), a Child-Pugh score more than B (p=0.023), a CLIP score more than 2 (p=0.000) and a OKUDA score more than II (p=0.000) showed significant differences. The evaluation of patients' factors would be useful to predict extended post-procedural hospitalization after hepatic chemoembolisation

  1. Preliminary results of transarterial Rhenium-188 HDD Lipiodol in treatment of inoperable primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Sundram, Felix

    2004-01-01

    Full text: In this paper we present our early experience with a new radio-conjugate, namely rhenium-188 HDD Lipiodol (Re-188 lipiodol). Imported radiopharmaceuticals are generally expensive, particularly for developing countries. A Tungsten (W-188-Re 188) generator obtained from ORNL (Oak Ridge National Laboratory, Tennessee, USA) allows us on-site production of a beta emitting therapeutic isotope (Re-188) for up to 6 months from a single generator. The objectives of this study were to establish the safety of trans-arterial Re-188 lipiodol in patients with inoperable HCC, and determine the adverse effects and efficacy for this radio-conjugate treatment in a multi-center study of patients with advanced HCC. A multi-center study was sponsored by the International Atomic Energy Agency (Vienna) to assess the safety and efficacy of trans-arterial Re-188 HDD conjugated lipiodol (radio-conjugate) in the treatment of patients with inoperable hepatocellular carcinoma (HCC), The radio-conjugate was prepared by using a HDD (4-hexadecyl 1-2, 9, 9-tetramethyl-4, 7-diaza-1, 10-decanethiol) kit developed in Korea, and lipiodol. Over a period of eighteen months seventy patients received at least one treatment of radio-conjugate. Some patients were re-treated if there was no evidence of disease progression. The level of radio-conjugate administered was based on radiation-absorbed dose to critical normal organs, calculated following a 'scout' dose of radio-conjugate. The organs at greatest risk for radiation toxicity are the normal liver, the lung and the bone marrow. A specially designed spreadsheet was used to determine maximum tolerated activity (MTA), defined as the amount of radioactivity calculated to deliver no more than 12 Gray (Gy) to lungs, or 30 Gy to liver, or 1.5 Gy to bone marrow. These doses have been found to be safe in multiple trials using external beam therapy and systemically administered radiopharmaceuticals. Patients were followed for at least twelve weeks

  2. 2-octyl-cyanoacrylate glue for fixation of STSG in genitourinary tissue defects due to Fournier gangrene: a preliminary trial.

    Science.gov (United States)

    Sivrioğlu, Nazan; Irkören, Saime; Ceylan, Ender; Sonel, Ali Murat; Copçu, Eray

    2013-05-01

    In these reported cases, we observed the outcomes of skin take and wound healing using 2-octyl-cyanoacrylate glue, which was used as tissue glue in the reconstruction of complex genital skin loss due to fournier gangrene. Fifteen patients with Fournier's gangrene were treated in this study. After initial surgical debridement, all defects were repaired using STSG. In this method a thin layer of 2-octyl-cyanoacrylate was dripped on the recipient site immediately before graft application. All wounds were followed up postoperatively and observed for evidence of graft take, seroma or hematoma formation, drainage, and infection. Patient and physician satisfaction were also determined. Grafts were completely accepted in all fifteen patients. None of the patients had wound infection, seroma, hematoma, or other complications. Use of 2-octyl-cyanoacrylate glue (Glueseal) for STSG fixation in complex genital skin defects after Fournier gangrene may be an acceptable alternative to conventional surgical closure with a good cosmetic outcome. Further studies are needed to confirm our initial success with this approach.

  3. Glue ear: how good is the information on the World Wide Web?

    Science.gov (United States)

    Ritchie, L; Tornari, C; Patel, P M; Lakhani, R

    2016-02-01

    This paper objectively evaluates current information available to the general public related to glue ear on the World Wide Web. The term 'glue ear' was typed into the 3 most frequently used internet search engines - Google, Bing and Yahoo - and the first 20 links were analysed. The first 400 words of each page were used to calculate the Flesch-Kincaid readability score. Each website was subsequently graded using the Discern instrument, which gauges quality and content of literature. The websites Webmd.boots.com, Bupa.co.uk and Patient.co.uk received the highest overall scores. These reflected top scores in either readability or Discern instrument assessment, but not both. Readability and Discern scores increased with the presence of a marketing or advertising incentive. The Patient.co.uk website had the highest Discern score and third highest readability score. There is huge variation in the quality of information available to patients on the internet. Some websites may be accessible to a wide range of reading ages but have poor quality content, and vice versa. Clinicians should be aware of indicators of quality, and use validated instruments to assess and recommend literature.

  4. Use of fibrin glue derived from snake venom in the repair of deep corneal ulcers: experimental study in dogs (Canis familiaris, Linnaeus, 1758

    Directory of Open Access Journals (Sweden)

    R. L. Sampaio

    2007-01-01

    Full Text Available Fibrin glue has been researched as an alternative method for tissue synthesis and is known for its capability to promote hemostasis at the application site, good approximation of wound edges and fast healing. The current study consisted in the application of fibrin glue derived from snake venom as treatment for experimental corneal ulcers. Twenty-one dogs had their corneas experimentally prepared through lamellar keratectomy (of standardized diameter and depth. Animals were divided into seven groups of three animals each. Six experimental groups were periodically evaluated and collection was carried out on the 1st, 3rd, 7th, 15th, 30th and 60th post-operative days, whereas one control group was evaluated throughout the experiment. Analyses consisted in the clinical evolution and in the histopathological study of all operated on eyes. Results indicated that fibrin glue was efficient in repairing keratectomy wounds in dogs and contributed to an earlier healing phenomenon, avoiding edema formation and keeping corneal clearness. The use of fibrin glue derived from snake venom showed to be easy to apply, feasible with animal models and of low cost, avoiding the lesion progress and allowing fast and appropriate corneal healing.

  5. Analysis of stress- strain distribution of dowel and glue line in L-type furniture joint by means of finite element method

    Directory of Open Access Journals (Sweden)

    mossayeb dalvand

    2017-08-01

    Full Text Available In this study 3D stress-strain distribution of dowel and glue line on L-type joints made of plywood doweled was investigated. Members of joints made of 11-ply hardwood plywood (Hornbeam, Beech and Alder that were 19 mm in thickness. In this study effect of beech dowels in three levels diameters (6, 8 and 10 mm and penetration of depth (9, 13 and 17 mm on bending moment capacity of L-type joints under compression loading was investigated as experimental test, then stress-strain distribution of wood dowel and glue line in specimens were simulated by means of ANSYS 15 software with finite element method (FEM.Results have shown that bending moment resistance increased with increasing dowel diameter from 6 to 8 mm, but downward trend was observed with increasing 8 to 10 mm in dowel diameter. Bending moment resistance increased with increasing penetration depth. Also, result obtained of simulation by means of ANSYS software have shown that stress-strain in dowel and glue line increased with increasing diameter of dowel and Increasing stress in joints made of diameter dowel 10 mm due to fracture in joints and decrease in resistance once. According to results obtained of model analysis, the ultimate stress of dowel and glue line occurred in the area that joints were contacted.

  6. Performance of fast-absorbable suture and histo-glue in closing incisions in Brown trout

    DEFF Research Database (Denmark)

    Jepsen, Niels; Larsen, Martin Hage; Aarestrup, Kim

    2017-01-01

    , growth, tag expulsion rate and incision healing was compared among three groups of dummy transmitter-tagged wild brown trout Salmo trutta where incisions were closed with two types of suture material (absorbable vs. fast absorbable) and Histo-glue. The tagged fish were kept in semi-natural ponds for 20...

  7. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue.

    NARCIS (Netherlands)

    Hallers, E.J.O. ten; Jansen, J.A.; Marres, H.A.M.; Rakhorst, G.; Verkerke, G.J.

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  8. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E.J. Olivier; Jansen, John A.; Marres, Henri A.M.; Rakhorst, Gerhard; Verkerke, Gijsbertus Jacob

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  9. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E. J. Olivier; Jansen, John A.; Marres, Henri A. M.; Rakhorst, Gerhard; Verkerke, Gijsbertus J.

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  10. A unique and unexplained ricochet leak post PCI – Successfully treated with intra-coronary glue

    Directory of Open Access Journals (Sweden)

    Pravin K. Goel

    2014-01-01

    Full Text Available We herein describe a unique case of coronary artery perforation treated with covered stent with repeat cardiac tamponade resulting out of a fresh unexplained leak from a remote vessel (Ricochet and successfully treated with intra-coronary injection of sterile synthetic glue, cyanoacrylate.

  11. EFFICACY OF THROMBIN FIBRIN GLUE AND SCLE ROSANT IN THE MANAGEMENT OF BLEEDI NG GASTRIC VARICES

    Directory of Open Access Journals (Sweden)

    Sanjay Gupta

    2015-01-01

    Full Text Available Gastric varices are noted in up to 20 % of patents with portal hypertension , and are more common in those with non - cirrhotic etiology 1 . They bleed at lower portal pressures , bleed more severely and are associated with higher rates of rebleed , encephalopathy and mortality 1,2,3 . Variceal obliteration using tissue adhesives such as N - butyl cyanoacrylate leading to plugging and thrombosis of the gastric varices is currently the first line management option for obliteration of the gastric varices 3 . Although various options have been proposed , gold standard for management of gastric variceal bleeds is yet to be defined. We theorized that injection of the gastric varices using thrombin based glue followed by injection of a sclerosant shall be effective in optimum sclerotherapy and eradication of gastric varices. MATERIAL AND METHODS : All patients presenting with gastric variceal bleed were offered sclerotherapy with Thrombin fibrin based glue and sclerosant (TFG/S . During the study period 18 patients were enrolled in the TGF/S group. 21 patients underwent variceal plugging with n - butyl cyanoacrylate (NBC . There was no significant difference in age/ sex , duration of bleed or time interval between onset of bleed and endotherapy. RESULTS: Patients undergoing endotherapy with TGF/S had less episodes of bleed , and greater eradication of varices. CONCLUSION: The results with thrombin / fibrin glue and sclerotherapy are highly encouraging. Well - designed trials need to be performed KEYWORDS:Gastric varices; Thrombin Sclerotherapy

  12. Strenght of the glue line of edge glued panels of Pinus taeda made with different adhesives

    Directory of Open Access Journals (Sweden)

    Merielen de Carvalho Lopes

    2013-12-01

    Full Text Available The study compares the strength of the glue line of edge glued panels of Pinus taeda made with different industrial adhesives. Three types of adhesives (poly(vinyl acetate (PVAc, emulsion polymer isocyanate (EPI and polyurethane (PU glued in two side gluing orientation (radial and tangential and analyzed after the conditioning tests (dry and wet were analyzed. The 360 specimens were prepared for determining the shear strength of edge glued panels of Pinus taeda, and these were tested in a universal testing machine called EMIC. The shear strength of the glue line at dry condition was lower in the tangential side for the three types of adhesives analyzed. The PU adhesive showed the highest values of shear strength in the applied conditions, differing from PVAc and EPI adhesive when tested on dry condition and did not differ from the others adhesives when tested on wet condition. The highest percentage of wood failure was observed after the shear strength test at dry condition to EPI adhesive glued in the radial side. And in the wet condition, the EPI adhesive and PU adhesive glued in tangential side showed higher mean values of wood failure. Thus, it was possible to conclude that the strength of the glue line of Pinus taeda wood was influenced by the type of adhesive and side gluing orientation, and showed differently behavior according to the condition of use (wet or dry.

  13. Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments

    Science.gov (United States)

    Baba, Seiki; Hoshino, Takeshi; Ito, Len; Kumasaka, Takashi

    2013-01-01

    Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection. PMID:23999307

  14. Effect of fibrin glue derived from snake venom on the viability of autogenous split-thickness skin graft

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2004-01-01

    Full Text Available The aim of this study was to analyze the effect of snake venom derived from fibrin glue on the viability of split-thickness skin graft. Nine crossbreed dogs were used. Full-thickness skin segments measuring 4 x 4 cm were bilaterally excised from the proximal radial area on each dog. A split-thickness skin graft was harvestedfrom left lateral thoracic area using a freehand graft knife, and was secured to the left recipient bed using several simple interrupted sutures of 3-0 nylon (sutured graft. A split-thickness skin graft was harvested from the right lateral thoracic area using a graft knife. Fibrin glue derived from snake venom was applied to the recipient bed, and 8 equidistant simple interrupted sutures of 3-0 nylon were used to secure the skin graft (glued graft. Viable and nonviable areas were traced on a transparent sheet and measured using a Nikon Photomicroscope connected to a KS-300 image analysis system. The skin graft and recipient bed were collected from three dogs at day 7, 15, and 30 postoperative. The glued grafts had statistically higher graft viability than sutured grafts. Histological examination showed that the tissue repair process in the glued grafts was more accentuated than sutured grafts. It was possible to conclude that fibrin glue derived from snake venom increased survival of autogenous split-thickness skin graft.

  15. Development of Self Fire Retardant Melamine-Animal Glue Formaldehyde (MGF) Resin for the Manufacture of BWR Ply Board

    Science.gov (United States)

    Khatua, Pijus Kanti; Dubey, Rajib Kumar; Roymahapatra, Gourisankar; Mishra, Anjan; Shahoo, Shadhu Charan; Kalawate, Aparna

    2017-10-01

    Wood is one of the most sustainable, naturally growing materials that consist mainly of combustible organic carbon compounds. Since plywood are widely used nowadays especially in buildings, furniture and cabinets. Too often the fire behavior of ply-board may be viewed as a drawback. Amino-plastic based thermosetting resin adhesives are the important and most widely used in the plywood panel industries. The fire retardant property of wood panel products by adding animal glue as an additive in the form of MGF resin and used as substitute of melamine for manufacture of plywood. Environment concerns and higher cost of petroleum based resins have resulted in the development of technologies to replace melamine partially by biomaterials for the manufacturing of resin adhesive. Natural bio-based materials such as tannin, CNSL (cardanol), lignin, soya etc. are used as partial substitution of melamine. This article presents the development of melamine-animal glue formaldehyde resin as plywood binder. About 30 % melamine was substituted by animal glue and optimized. The different physico-mechanical and fire retardant property properties tested as per IS: 1734-1983 and IS: 5509-2000 respectively are quite satisfactory. The production of adhesive from melamine with compatible natural proteinous material is cost effective, eco-friendly and enhance the fire retardant property.

  16. Analog experiment of transarterial catheter hyperthermic infusion in vitro

    International Nuclear Information System (INIS)

    Fan Shufeng Li Zheng; Gu Weizhong; Ru Fuming

    2006-01-01

    Objective: To investigate the factors related to the heating effect by transarterial catheter hyperthermic infusion with the evaluation of the feasibility in controlling the tumor temperature. Methods: Infusing 55-68 degree C liquid at the speed of 10-40 ml/min through 6F, 5F or 3F catheter with different length respectively under the similar clinical condition. The liquid temperature at the terminal exit of the catheter was measured with a digital thermometer. The factors related to the liquid temperature at the exit of the catheter were analyzed by multiple regression analysis. Results: The infusion temperature , rate and the catheter length were the main related factors to the liquid temperature at the exit of the catheter as the condition similar in clinical use. When 60-65 degree C liquid was infused at the rate of 20-40 ml/min through 5F catheter with length of 80 cm, the mean and 95% confident interval of the liquid temperature at the catheter exit were (47.55±0.44) degree C and 44.61-48.49 degree C respectively. Conclusions: The liquid temperature at the exit of infusion catheter can be regulated and controlled through adjusting the liquid perfusion temperature and speed. (authors)

  17. Preoperative embolization of hypervascular head and neck tumours

    International Nuclear Information System (INIS)

    Gupta, A. K.; Purkayastha, S.; Bodhey, N. K.; Kapilamoorthy, T. R.; Kesavadas, C.

    2007-01-01

    Full text: The embolization of vascular tumours of the head and neck has become an important adjunct to the surgical treatment of these tumours. A vascular tumour in the head and neck region in a surgically treatable patient may be a candidate for embolization. Palliative embolization may be the sole treatment for high risk patients. Reducing intraoperative bleeding may shorten surgery time thus decreasing morbidity and mortality. The purpose of this study is to assess the efficacy of embolization as an adjunct to surgery or as a curative measure in the management of hypervascular head and neck tumours. We retrospectively reviewed the records of 46 consecutive patients 27 men and 16 women; mean age, 37.8 years) with 48 hypervascular head and neck tumours that had undergone preoperative transarterial, direct puncture or combined mode of embolization. Diagnosis of tumours was made on the basis of findings of imaging studies. The 46 patients underwent embolization either through transarterial route, by direct puncture technique or both direct puncture and arterial route. The devascularization reached 90-95% with the use of NBCA. The amount of devascularization reached by transarterial particle embolization is a little lesser. One patient (carotid body tumour) developed mild unilateral seventh, ninth and 10th cranial nerve palsy after transarterial embolization, transient hemiparesis was seen in another patient (nasopharyngeal angiofibroma). Both patients improved completely with steroids and had no deficit on follow up. One patient developed delayed glue migration into the middle cerebral artery territory 6 h after the procedure with no reported increase in size of the lesion in the following 5 years. Preoperative embolization of hypervascular tumour of head and neck region appears to be safe and improves the chance of complete removal during surgery with minimal blood loss

  18. Migration to the GLUE 2.0 information schema in the LCG/EGEE/EGI production Grid

    International Nuclear Information System (INIS)

    Burke, Stephen; Field, Laurence; Horat, David

    2011-01-01

    The GLUE information schema has been in use in the LCG/EGEE production Grid since the first version was released in 2002. In 2008 a major redesign of GLUE, version 2.0, was defined in the context of the Open Grid Forum. The implementation of the publication and use of the new schema is a complex process which needs to be carefully managed to avoid any disruption to the production service, especially in the light of the end of the EGEE project and the transition to the new middleware and operational structures in EGI. In this paper we discuss the LDAP rendering of the schema, the upgrading of the Grid information system to allow both schemas to be used in parallel, the design and rollout of information providers, and the plans for migrating client software which uses the schema information. In particular we consider the implications for the specific requirements of the LCG project, especially regarding storage systems, accounting and monitoring.

  19. Introduction of a potent single-donor fibrin glue for vascular anastomosis: An animal study

    Directory of Open Access Journals (Sweden)

    Mehdi Rasti Ardakani

    2012-01-01

    Full Text Available Background: Vascular anastomosis is considered as a difficult surgical procedure. Although different alternative methods have been tried to tackle these difficulties, none were found to be successful. Commercial fibrin glue has recently been used for vascular anastomosis. However, it did not gain popularity due to some limitations such as low tensile strength, rapid removal by the immune system, and risk of transmission of blood-borne viral infections. In this article, we presented a novel method for producing single-donor human fibrin glue and determined its success rate for vascular anastomosis in an animal model. Materials ans Methods : In this study, 3 mL of single-donor fibrin sealant was prepared from 150 mL of whole blood containing 50-70 mg/mL of fibrinogen. The study was performed on 10 dogs and 5 cats. After transection of the carotid artery, both ends were anastomosed by means of 3-4 sutures (Prolene 8-0. The suture line was then sealed with one layer of the new fibrin sealant. After 3-8 weeks, the site of anastomosis was evaluated angiographically and morphologically for healing and possible complications such as thrombosis or aneurysm. Results: In evaluations 3 weeks after the surgery, all arterial anastomoses were patent in dogs, but some degree of subintimal hyperplasia was noted. After 8 weeks, all anastomoses were patent and the degree of subintimal hyperplasia was decreased. In cats on the other hand, after 4 weeks, all anastomoses were patent and subintimal hyperplasia was absent. Conclusions: Single-donor fibrin glue was a quite reliable and practical alternative to minimize suturing and therefore operative time in our animal model. This sealant can easily be obtained from the patient′s whole blood. Its application in humans would require further studies.

  20. [Use of fibrin glue in the prevention of leakage in pancreatico-jejunal anastomoses].

    Science.gov (United States)

    Stojanović, M; Jeremic, M; Stojanović, P; Stojiljković, M; Gmijović, D; Stanojković, Z; Savić, V; Djordjević, V; Cvetković, Z; Kostov, M; Colović, R

    2002-01-01

    The aim of this study was to test the protective effects of fibrin sealing on the pancreatico-jejunostomy (PJA), the high-risk anastomosis following pancreas head resection. Experimental study was performed on the mongrel dogs, divided in two groups (20 animals each): Experimental group-with end to end "dunking" PJA, protected by temporary occlusion of the pancreatic duct with fibrin sealant/Tissucol/Immuno Ag/, while control group was without any protective procedure. The animals were followed 5 months in order to study: protective effects of such procedure on the PJA quantified with the percent of anastomotic leakage, effects of the exocrine secretion and effects the endocrine function Results: PJA leakage occurred in 13.33% in control group. No leakage was registered in experimental group. Biochemical, histological and electron microscopic study showed slight transitory elevation of amylase levels. Fibrin glue plug was dissolved and pancreatic juice output was reestablished 12th days postoperatively. Long term follow-up showed no damages of the endocrine and exocrine pancreas. Pancreatic duct occlusion with fibrin glue appeared to be an useful method in the prevention of pancreatico-jejunostomy leakage, without negative effects on the exocrine and endocrine pancreas.

  1. Clinical observation on fibrin glue technique in pterygium surgery performed with limbal autograft transplantation

    Directory of Open Access Journals (Sweden)

    Hui Liu

    2013-07-01

    Full Text Available AIM: To compare the efficiency and safety of fibrin glue to suture technique in pterygium surgery performed with limbal autograft.METHODS: A prospective randomized clinical trial was carried out in 60 eyes of 48 patients operated for primary nasal pterygium. Autologous limbal graft taken from the superotemporal limbus was used to cover the sclera after pterygium excision under local anesthesia with 2% lidocaine. In 22 cases(30 eyes, the transplant was attached to the sclera with a fibrin tissue adhesive(group 1and in 26 cases(30 eyeswith 10-0 Virgin silk sutures(group 2. Patients were followed up at least for 3 months. Time of operation, matching degree of graft and visual analogue scale(VASscore were mainly observed and recorded. RESULTS: Patient symptoms were significantly less and biomicroscopic findings were better in group 1. Pterygium recurrence was seen in 1 case of group 1, and 1 case of group 2. Average surgery time was shorter(PCONCLUSION: Using fibrin glue for graft fixation in pterygium surgery causes significantly less postoperative pain and shortens surgery time significantly.

  2. Glue-sniffing as a cause of a positive radio-isotope brain scan

    Energy Technology Data Exchange (ETDEWEB)

    Lamont, C M; Adams, F G

    1982-08-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas of increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing.

  3. Glue-sniffing as a cause of a positive radio-isotope brain scan

    International Nuclear Information System (INIS)

    Lamont, C.M.; Adams, F.G.

    1982-01-01

    Convulsions are a known complication of the acute intoxicant effects of solvent abuse. A radio-isotope brain scan done 9 months following status epilepticus secondary to toluene inhalation, in a previously normal school-boy, demonstrated several wedge-shaped areas if increased uptake, in both cerebral hemispheres, consistent with infarcts. It is worth remembering that a positive brain scan in a young person, with recent onset of epilepsy, may be due to glue-sniffing. (orig.)

  4. The complicated management of a patient following transarterial chemoembolization for metastatic carcinoid

    Directory of Open Access Journals (Sweden)

    Shah Manisha H

    2008-11-01

    Full Text Available Abstract Background Transarterial Chemoembolization (TACE has been recognized as a successful way of managing symptomatic and/or progressive hepatic carcinoid metastases not amenable to surgical resection. Although it is a fairly safe procedure, it is not without its complications. Case presentation This is a case of a 53 year-old woman with a patent foramen ovale (PFO and mild pulmonary hypertension who underwent TACE for progressive carcinoid liver metastases. She developed acute heart failure, due to a severe inflammatory response; this resulted in pneumatosis intestinalis due to non-occlusive mesenteric ischemia. We describe the successful non-operative management of her pneumatosis intestinalis and the role of a PFO in this patient's heart failure. Conclusion TACE remains an effective and safe treatment for metastatic carcinoid not amenable to resection, this case illustrates the complexity of complications that can arise. A multi-disciplinary approach including ready access to advanced critical care facilities is recommended in managing such complex patients.

  5. [Research of repairing rabbit knee joint cartilage defect by compound material of fibrin glue and decalcified bone matrix (DBM) and chondrocytes].

    Science.gov (United States)

    He, Jie; Yang, Xiang; Yue, Peng-ju; Wang, Guan-yu; Guo, Ting; Zhao, Jian-ning

    2009-07-01

    To investigate the feasibility and effectivity of using compound material of fibrin glue and DBM as scaffolds for cartilage tissue engineering. Chondrocytes isolated from articular cartilage were seeded into prepared scaffolds, after incubation for 4 weeks in vitro. Chondrocytes and fibrin glue and DBM constructs were implanted in the joint cave of rabbit. The specimens were excised at the 4th, 8th, 12th week, examined grossly analyzed by haematoxylin cosine, toluidine blues staining and type II collagen immunohistochemistry reaction. Wakitani score was counted to evaluate the repairing effect. Grossly analysis showed some ivory tissue filled the caves after 4 weeks and the caves were full filled with smooth surface after 12 weeks. The microscope showed a good deal of chondrocytes appeared after 8 weeks and more type II collagen than 4 weeks. Twelve weeks later, cartilage lacuna could be observed. The cells arrangement and the amount of type II collagen both showed the same as the natural one. Complicated material of fibrin glue and DBM as scaffolds can be used as scaffolds for cartilage tissue engineering.

  6. Transarterial chemoembolisation (TACE) with gemcitabine: Phase II study in patients with liver metastases of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.de; Jakobi, Silke; Gruber-Rouh, Tatjana; Hammerstingl, Renate; Vogl, Thomas J.; Zangos, Stephan

    2013-12-01

    Objective: Evaluation of the efficacy and tolerability of transarterial chemoembolization with gemcitabine in patients with inoperable liver metastases of breast cancer. Materials and methods: Open-label, prospective non-randomized single-center study design; patients had previous chemotherapy including anthracyclines and/or taxanes in the metastatic setting, adequate bone marrow reserve, sufficient liver/renal function, no centralnervous system metastases, Karnovsky-performance-status >70%, and life expectancy >12 weeks. Forty-three patients were enrolled (median 58 years, range 48–71). A suspension of gemcitabine 1.200 mg/m{sup 2}, 2–10 ml/m{sup 2} of Lipiodol, and 5 ml of a degradable starch microsphere (Embocept) suspension, were administered intra-arterially up to 3 times with a 4-weaks-interval. Dose-limiting toxicit is defined as grade 4 thrombocytopenia, neutropenia, or nonhematologic toxicity > grade 3. Tumor response was evaluated by magnetic resonance (MRI) and computed tomography (CT) imaging. Results: All patients tolerated the treatment well; with no dose limiting toxicities. Imaging follow-up according to the RECIST-criteria (Response Evaluation Criteria in Solid Tumors) revealed a partial response in 3 patients, stable disease in 16 patients and progression in 22 patients. The progression free survival was 3.3 months. A significant correlation exists only with the factor vascularization: strongly vascularized tumors show a significantly lowered response. Patients with complete or partial response and the main fraction of the stable disease group showed in the MRI and angiography only a moderate vascularization. The resulting estimate of the total survival rate amounts to a median of 10.2 months. Conclusion: Transarterial chemoembolization with gemcitabine is well tolerated and provides an alternative treatment method for patients with liver metastases of breast cancer.

  7. Albumin-Bilirubin and Platelet-Albumin-Bilirubin Grades Accurately Predict Overall Survival in High-Risk Patients Undergoing Conventional Transarterial Chemoembolization for Hepatocellular Carcinoma.

    Science.gov (United States)

    Hansmann, Jan; Evers, Maximilian J; Bui, James T; Lokken, R Peter; Lipnik, Andrew J; Gaba, Ron C; Ray, Charles E

    2017-09-01

    To evaluate albumin-bilirubin (ALBI) and platelet-albumin-bilirubin (PALBI) grades in predicting overall survival in high-risk patients undergoing conventional transarterial chemoembolization for hepatocellular carcinoma (HCC). This single-center retrospective study included 180 high-risk patients (142 men, 59 y ± 9) between April 2007 and January 2015. Patients were considered high-risk based on laboratory abnormalities before the procedure (bilirubin > 2.0 mg/dL, albumin 1.2 mg/dL); presence of ascites, encephalopathy, portal vein thrombus, or transjugular intrahepatic portosystemic shunt; or Model for End-Stage Liver Disease score > 15. Serum albumin, bilirubin, and platelet values were used to determine ALBI and PALBI grades. Overall survival was stratified by ALBI and PALBI grades with substratification by Child-Pugh class (CPC) and Barcelona Liver Clinic Cancer (BCLC) stage using Kaplan-Meier analysis. C-index was used to determine discriminatory ability and survival prediction accuracy. Median survival for 79 ALBI grade 2 patients and 101 ALBI grade 3 patients was 20.3 and 10.7 months, respectively (P  .05). ALBI and PALBI grades are accurate survival metrics in high-risk patients undergoing conventional transarterial chemoembolization for HCC. Use of these scores allows for more refined survival stratification within CPC and BCLC stage. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  8. Study of severe and rare complications of transarterial chemoembolization (TACE) for liver cancer

    International Nuclear Information System (INIS)

    Xia Jinglin; Ren Zhenggang; Ye Shenglong; Sharma Dilip; Lin Zhiying; Gan Yuhong; Chen Yi; Ge Ninglin; Ma Zengchen; Wu Zhiquan; Fan Jia; Qin Lunxiu; Zhou Xinda; Tang Zhaoyou; Yang Binghui

    2006-01-01

    Objective: To study severe and rare complications of transarterial chemoembolization (TACE) for liver cancer. Methods: Clinical records of severe and rare complications following TACE in 1348 cases of liver cancer from January 1997 to February 2004 were studied retrospectively. Results: A total of 2012 TACE procedures were performed for 1348 patients. There were 3 cases of spontaneous rupture of liver cancer, 1 case of perforation of duodenum, 3 cases of liver abscess (1 of them was associated with sepsis), 1 case of pulmonary embolism, 1 case of spasm of the hepatic artery, 40 cases of hepatic artery occlusion, 3 cases of femoral nerve injury, 1 case of bilioma and 1 case of acute renal failure. Conclusion: Although the severe complications of TACE are rare, the procedure should be done cautiously including super selection of hepatic artery, slow infusion of lipiodol, careful postoperative observations and early detection and management of complications

  9. Elaboración de cola de pergamino = Preparation of parchment glue

    OpenAIRE

    Tacón Clavaín, Javier

    2013-01-01

    En las páginas siguientes se describe mediante imágenes el proceso llevado a cabo en el Departamento de Conservación y Restauración para la elaboración de cola de pergamino. Este adhesivo tradicional es muy adecuado para su uso en consolidaciones y adhesiones en el campo de la restauración documental por su pureza y por su pH neutro. [ABSTRACT]In the following pages the process carried out in the Department of Conservation and Restoration for making parchment glue is described. This tradit...

  10. Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes.

    Science.gov (United States)

    Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich

    2011-01-01

    Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier

  11. Effects of albumin/glutaraldehyde glue on healing of colonic anastomosis in rats

    Science.gov (United States)

    Despoudi, Kalliopi; Mantzoros, Ioannis; Ioannidis, Orestis; Cheva, Aggeliki; Antoniou, Nikolaos; Konstantaras, Dimitrios; Symeonidis, Savvas; Pramateftakis, Manousos George; Kotidis, Efstathios; Angelopoulos, Stamatis; Tsalis, Konstantinos

    2017-01-01

    AIM To evaluate the effect of local surgical adhesive glue (albumin/glutaraldehyde-Bioglue) on the healing of colonic anastomoses in rats. METHODS Forty Albino-Wistar male rats were randomly divided into two groups, with two subgroups of ten animals each. In the control group, an end-to-end colonic anastomosis was performed after segmental resection. In the Bioglue group, the anastomosis was protected with extraluminar application of adhesive glue containing albumin and glutaraldehyde. Half of the rats were sacrificed on the fourth and the rest on the eighth postoperative day. Anastomoses were resected and macroscopically examined. Bursting pressures were calculated and histological features were graded. Other parameters of healing, such as hydroxyproline and collagenase concentrations, were evaluated. The experimental data were summarized and computed from the results of a one-way ANOVA. Fisher’s exact test was applied to compare percentages. RESULTS Bursting pressures, adhesion formation, inflammatory cell infiltration, and collagen deposition were significantly higher on the fourth postoperative day in the albumin/glutaraldehyde group than in the control group. Furthermore, albumin/glutaraldehyde significantly increased adhesion formation, inflammatory cell infiltration, neoangiogenesis, and collagen deposition on the eighth postoperative day. There was no difference in fibroblast activity or hydroxyproline and collagenase concentrations. CONCLUSION Albumin/glutaraldehyde, when applied on colonic anastomoses, promotes their healing in rats. Therefore, the application of protective local agents in colonic anastomoses leads to better outcomes. PMID:28883693

  12. Inorganic Glue Enabling High Performance of Silicon Particles as Lithium Ion Battery Anode

    KAUST Repository

    Cui, Li-Feng

    2011-01-01

    Silicon, as an alloy-type anode material, has recently attracted lots of attention because of its highest known Li+ storage capacity (4200 mAh/g). But lithium insertion into and extraction from silicon are accompanied by a huge volume change, up to 300, which induces a strong strain on silicon and causes pulverization and rapid capacity fading due to the loss of the electrical contact between part of silicon and current collector. Silicon nanostructures such as nanowires and nanotubes can overcome the pulverization problem, however these nano-engineered silicon anodes usually involve very expensive processes and have difficulty being applied in commercial lithium ion batteries. In this study, we report a novel method using amorphous silicon as inorganic glue replacing conventional polymer binder. This inorganic glue method can solve the loss of contact issue in conventional silicon particle anode and enables successful cycling of various sizes of silicon particles, both nano-particles and micron particles. With a limited capacity of 800 mAh/g, relatively large silicon micron-particles can be stably cycled over 200 cycles. The very cheap production of these silicon particle anodes makes our method promising and competitive in lithium ion battery industry. © 2011 The Electrochemical Society.

  13. Non-variceal upper gastrointestinal bleeding: Rescue treatment with a modified cyanoacrylate.

    Science.gov (United States)

    Grassia, Roberto; Capone, Pietro; Iiritano, Elena; Vjero, Katerina; Cereatti, Fabrizio; Martinotti, Mario; Rozzi, Gabriele; Buffoli, Federico

    2016-12-28

    To evaluate the safety and efficacy of a modified cyanoacrylate [N-butyl-2-cyanoacrylate associated with methacryloxysulfolane (NBCA + MS)] to treat non-variceal upper gastrointestinal bleeding (NV-UGIB). In our retrospective study we took into account 579 out of 1177 patients receiving endoscopic treatment for NV-UGIB admitted to our institution from 2008 to 2015; the remaining 598 patients were treated with other treatments. Initial hemostasis was not achieved in 45 of 579 patients; early rebleeding occurred in 12 of 579 patients. Thirty-three patients were treated with modified cyanoacrylate: 27 patients had duodenal, gastric or anastomotic ulcers, 3 had post-mucosectomy bleeding, 2 had Dieulafoy's lesions, and 1 had duodenal diverticular bleeding. Of the 45 patients treated endoscopically without initial hemostasis or with early rebleeding, 33 (76.7%) were treated with modified cyanoacrylate glue, 16 (37.2%) underwent surgery, and 3 (7.0%) were treated with selective transarterial embolization. The mean age of patients treated with NBCA + MS (23 males and 10 females) was 74.5 years. Modified cyanoacrylate was used in 24 patients during the first endoscopy and in 9 patients experiencing rebleeding. Overall, hemostasis was achieved in 26 of 33 patients (78.8%): 19 out of 24 (79.2%) during the first endoscopy and in 7 out of 9 (77.8%) among early rebleeders. Two patients (22.2%) not responding to cyanoacrylate treatment were treated with surgery or transarterial embolization. One patient had early rebleeding after treatment with cyanoacrylate. No late rebleeding during the follow-up or complications related to the glue injection were recorded. Modified cyanoacrylate solved definitively NV-UGIB after failure of conventional treatment. Some reported life-threatening adverse events with other formulations, advise to use it as last option.

  14. Fibrin Glue Does Not Improve Healing of Gastrointestinal Anastomoses

    DEFF Research Database (Denmark)

    Nordentoft, Tyge; Pommergaard, Hans-Christian; Rosenberg, Jacob

    2015-01-01

    BACKGROUND/AIM: Anastomotic leakage remains a frequent and serious complication in gastrointestinal surgery. In order to reduce its incidence, several clinical and experimental studies on anastomotic sealing have been performed. In a number of these studies, the sealing material has been fibrin...... glue (FG), and the results in individual studies have been varying. The positive effect of anastomotic sealing with FG might be due to the mechanical/physical properties, the increased healing of the anastomoses or both. The aim of this systematic review was to evaluate the existing evidence....... It is consequently plausible that the positive effect of FG sealing of gastrointestinal anastomoses, if there is any, may be due to a mechanical sealing effect rather than due to improved healing per se....

  15. Comparative uncertainty analysis of copper loads in stormwater systems using GLUE and grey-box modeling

    DEFF Research Database (Denmark)

    Lindblom, Erik Ulfson; Madsen, Henrik; Mikkelsen, Peter Steen

    2007-01-01

    . With the proposed model and input data, the GLUE analysis show that the total sampled copper mass can be predicted within a range of +/- 50% of the median value ( 385 g), whereas the grey-box analysis showed a prediction uncertainty of less than +/- 30%. Future work will clarify the pros and cons of the two methods...

  16. In vitro study of a new biodegradable nanocomposite based on poly propylene fumarate as bone glue

    Energy Technology Data Exchange (ETDEWEB)

    Shahbazi, S.; Moztarzadeh, F. [Department of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Sadeghi, G. Mir Mohamad [Department of Polymer Engineering and Color Technology, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Jafari, Y., E-mail: y.j.arisman@gmail.com [Department of Analytical Chemistry, Faculty of Chemistry, University of Kashan, Kashan (Iran, Islamic Republic of)

    2016-12-01

    A novel poly propylene fumarate (PPF)-based glue which is reinforced by nanobioactive glass (NBG) particles and promoted by hydroxyethyl methacrylate (HEMA) as crosslinker agent, was developed and investigated for bone-to-bone bonding applications. In-vitro bioactivity, biodegradability, biocompatibility, and bone adhesion were tested and the results have verified that it can be used as bone glue. In an in-vitro condition, the prepared nanocomposite (PPF/HEMA/NBG) showed improved adhesion to wet bone surfaces. The combined tension and shear resistance between two wet bone surfaces was measured, and its maximum value was 9 ± 59 MPa. To investigate the bioactivity and biodegradability of the nanocomposite, it has been immersed in simulated body fluid (SBF). After 14 days exposure to SBF, a hydroxyapatite (HA) layer formed on the surface of the composite confirms the bioactivity of this material. In the XRD pattern of the nanocomposite surface, the HA characteristic diffraction peak at θ = 26 and 31.8 were observed. Also, by monitoring the weight change after 8 weeks immersion in SBF, the mass loss was about 16.46 wt%. It has been confirmed that this nanocomposite is a biodegradable material. Also, bioactivity and biodegradability of nanocomposite have been proved by SEM images. It has been showed that by using NBG particles and HEMA precursor, mechanical properties increased significantly. The ultimate tensile strength (UTS) of nanocomposite which contains 20% NBG and the ratio of 70/30 wt% PPF/HEMA (PHB.732) was approximately 62 MPa, while the UTS in the pure PPF/HEMA was about 32 MPa. High cell viability in this nanocomposite (MTT assays, 85–95%) can be attributed to the NBG nature which contains calcium phosphate and is similar to physiological environment. Furthermore, it possesses biomineralization and biodegradation which significantly affected by impregnation of hydrophilic HEMA in the PPF-based polymeric matrix. The results indicated that the new

  17. Utility of C-arm CT in overcoming challenges in patients undergoing Transarterial chemoembolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kulkarni, Chinmay; Sreekumar, K. P.; Prabhu, Nirmal Kumar; Kannan, Rajesh R; Moorthy, Srikanth

    2014-01-01

    Transarterial chemoembolization (TACE) is the well-known treatment for hepatocellular carcinoma. Multiple digital subtraction angiography (DSA) acquisitions in different projections are required to identify difficult arterial feeders. Moreover, the tell-tale tumor blush can be obscured by proximity to lung base, small size of lesion, and breathing artifacts. C-arm CT is a revolutionary advancement in the intervention radiology suite that allows acquisition of data which can be reformatted in multiple planes and volume rendered incorporating both soft tissue and vascular information like multidetector computed tomography (MDCT). These images acquired during the TACE procedure can provide critical inputs for achieving a safe and effective therapy. This case series aims to illustrate the utility of C-arm CT in solving specific problems encountered while performing TACE

  18. Pulmonary Lipiodol Accumulation after Transarterial Chemoembolization: CT Findings and Its Radiologic Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Youn, In Young; Chong, Se Min; Kwak, Byung Kook; Shin, Hyung Jin; Seo, Gi Young; Seo, Jae Seung; Kim, Jae Kyun [Dept. of Radiology, Chung Ang University Medical Center, Chung Ang University College of Medicine, Seoul (Korea, Republic of)

    2011-12-15

    To evaluate CT findings and radiologic outcomes of pulmonary lipiodol accumulation (PLA) after transarterial chemoembolization (TACE). This retrospective study involved 488 TACEs for hepatocellular carcinoma (HCC) (n = 160) and hepatic metastasis for non-hepatic malignancies (n = 7) in 167 patients. We reviewed the patient clinicoradiologic findings before and after TACE and calculated the incidence of PLA and PLA resolution time after initial CT and after TACE. Lipiodol accumulation in the lungs was seen under CT after TACE in seven patients (M : F = 6 : 1, mean age 61 years). The incidence of PLA at CT was 4.1% (7/167 patients). In five patients, associated intrathoracic abnormalities including pleural effusion with (n 3) or without consolidation (n = 2) were revealed at CT scans. The CT resolution time and PLA recovery time were 56 {+-} 54 days and 66 {+-} 52 days, respectively. The recovery time for lipiodol accumulation was 66 days. It is believed that the clinical and radiologic outcome of PLA without respiratory failure is promising, and conservative treatment will suffice when lipiodol accumulation in the lungs is seen in CT images after TACE.

  19. Identification and quantification of glue-like off-odors in elastic therapeutic tapes.

    Science.gov (United States)

    Denk, Philipp; Buettner, Andrea

    2018-05-01

    Elastic therapeutic tapes are an important tool in the field of physical therapy and medicine. These tapes contain types of adhesive. However, sensory evaluations revealed the release of pronounced and irritating odors of the tapes. Negative odors were, amongst others, reported in elastic therapeutic tapes containing acrylic adhesives. In this study, the odor of four different tape samples was evaluated applying a descriptive analysis approach carried out by a trained sensory panel. Afterwards, the volatile compounds were recovered from the samples by solvent extraction and isolated by solvent-assisted flavor evaporation (SAFE). The obtained distillates were subsequently analyzed by gas chromatography-olfactometry (GC-O) and two-dimensional GC-O coupled with mass spectrometry (2D-GC-MS/O). To determine the most potent odorants in the distillates, odor extract dilution analyses (OEDA) were carried out. Thirty-one odorants were successfully identified using this approach, which were all described for the first time as odorants in tapes. Amongst the set of volatiles, unsaturated and saturated aldehydes were present, eliciting fatty, soapy, and citrus-like odor impressions, as well as a range of glue-like, moldy, and fruity smelling odor-active volatiles, such as 2-ethyl-1-hexanol, butyl benzoate, and 3-phenyltoluene. Based on their relative intensities, the concentrations of the glue-like smelling substances were determined: 2-ethyl-1-hexanol, present in all samples, was determined with concentrations ranging from 10 to 200 mg/kg in the investigated tapes.

  20. Bulk physicochemical, interconnectivity, and mechanical properties of calcium phosphate cements-fibrin glue composites for bone substitute applications

    NARCIS (Netherlands)

    Lopez-Heredia, M.A.; Pattipeilohy, J.; Hsu, S.; Grykien, M.; Weijden, B. van der; Leeuwenburgh, S.C.G.; Salmon, P.; Wolke, J.G.C.; Jansen, J.A.

    2013-01-01

    Calcium phosphate cements (CPCs) and fibrin glue (FG) are used for surgical applications. Their combination is promising to create bone substitutes able to promote cell attachment and bone remodeling. This study proposes a novel approach to create CPC-FG composites by simultaneous CPC setting and FG

  1. Geometry effect on the behaviour of single and glue-laminated glass fibre reinforced polymer composite sandwich beams loaded in four-point bending

    International Nuclear Information System (INIS)

    Awad, Ziad K.; Aravinthan, Thiru; Manalo, Allan

    2012-01-01

    Highlights: ► Investigated the behaviour of single and glue-laminated GFRP sandwich beam. ► Effect of shear span to depth was a key factor affecting the overall behaviour. ► Comparison with prediction models gave reasonable results in specific regions. ► A failure map was developed to identify the shear and flexural failures of panels. -- Abstract: The research investigated the behaviour of single and glue laminated glass fibre reinforced polymer (GFRP) composite sandwich beams considering different spans and beam cross sections. The composite sandwich beams with different thicknesses (1, 2, 3, 4, and 5 sandwich layers) have been tested in four-point static flexural test with different shear span to depth ratio (a/d). The a/d ratios showed a direct effect on the flexural and shear behaviour. The capacity of the beam decreased with increasing a/d. Various failure modes were observed including core crushing, core shear, and top skin compression failure. The failure mode map developed based on the experimental finding and analytical prediction indicated that the failure mode is affected by the a/d with the number of glue laminated panels.

  2. Beam asymmetry Σ for π0 and η photoproduction on the proton at GlueX

    Science.gov (United States)

    Zhang, Zhenyu; GlueX Collaboration

    2016-09-01

    Measurements of meson photoproduction at high energies began almost 50 years ago with bubble chamber experiments at SLAC, DESY, and Cambridge. These data have been successfully described through Regge theory in terms of t-channel quasi-particle exchange. High statistics measurements of pseudoscalar meson photoproduction at GlueX, using the 9 GeV linearly-polarized, tagged photon beam in Jefferson Lab's Hall D, will provide important new constraints on these Regge models. These measurements will test our understanding of the photoproduction mechanism at high energy, which is a necessary first step toward the broader meson spectroscopy program at GlueX. Through finite energy sum rules, these measurements can also impose new constraints on the extraction of nucleon resonances from low energy photoproduction data. In this talk, preliminary results for the linearly polarized photon beam asymmetry Σ for the exclusive reactions γp -> pπ0 and γp -> pη will be presented. These are the first measurements of the η beam asymmetry at these energies. Supported by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177 and the China Scholarship Council No. 201506275156.

  3. Percutaneous sclerotherapy of massive macrocystic lymphatic malformations of the face and neck using fibrin glue with OK-432 and bleomycin.

    Science.gov (United States)

    Chen, W-l; Huang, Z-q; Chai, Q; Zhang, D-m; Wang, Y-y; Wang, H-j; Wang, L; Fan, S

    2011-06-01

    Picibanil (OK-432) and bleomycin have been used as alternative sclerosing agents for lymphatic malformations. This study evaluated the clinical curative effect of sclerotherapy using fibrin glue combined with OK-432 and bleomycin for the treatment of macrocystic lymphatic malformations of the face and neck. Fifteen paediatric patients (6 males; 9 females, aged 13 months to 14 years) who had received percutaneous sclerotherapy for massive macrocystic lymphatic malformations of the face and neck were retrospectively reviewed. Affected regions included the neck, parotid region and parapharynx, mouth floor, face and cheek, and orbital regions. All patients showed preoperative symptoms of space-occupying lesions between 4 cm × 5 cm and 12 cm × 16 cm in size. Fibrin glue with OK-432 and bleomycin was injected under general anaesthesia. All patients received preoperative and follow-up CT scans. Outcomes were assessed by three surgeons. All patients exhibited mid-facial swelling for 3-4 weeks after surgery, but no major complications. Follow-up periods ranged from 8 to 16 months. Eight lesions were completely involuted, five were mostly involuted, and two were partially involuted. Percutaneous sclerotherapy using fibrin glue with OK-432 and bleomycin provided a simple, safe, and reliable alternative treatment for massive macrocystic lymphatic malformations of the face and neck. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Transarterial Therapy for Hepatocellular Carcinoma: Which Technique Is More Effective? A Systematic Review of Cohort and Randomized Studies

    International Nuclear Information System (INIS)

    Marelli, Laura; Stigliano, Rosa; Triantos, Christos; Senzolo, Marco; Cholongitas, Evangelos; Davies, Neil; Tibballs, Jonathan; Meyer, Tim; Patch, David W.; Burroughs, Andrew K.

    2007-01-01

    Background. Chemoembolization (TACE) improves survival in cirrhotic patients with hepatocellular carcinoma (HCC). The optimal schedule, or whether embolization (TAE) alone gives the same survival advantage, is not known. Purpose. To evaluate whether specific patient characteristics and/or radiological transarterial techniques result in better outcomes. Method. A PubMed search was carried out for cohort and randomized trials (n = 175) testing transarterial therapies; meta-analysis was performed where appropriate. Results. Anticancer drugs were used as sole agent in 75% of cases (double 15% and triple 6%): doxorubicin (36%), cisplatin (31%), epirubicin (12%), mitoxantrone (8%), mitomycin (8%), and SMANCS (5%). Embolizing agents used were: gelatin sponge particles (71%), polyvinyl alcohol (PVA) particles (8%), degradable starch microspheres (DSM) (4%), and embospheres (4%). Sessions per patient were 2.5 ± 1.5 (interval: 2 months). Objective response was 40 ± 20%; survival rates at 1, 2, 3, and 5 years were: 62 ± 20%, 42 ± 17%, 30 ± 15%, and 19 ± 16%, respectively, and survival time was 18 ± 9.5 months. The post-TACE complications were: acute liver failure, 7.5% (range 0-49%); acute renal failure, 1.8% (0-13%); encephalopathy, 1.8% (0-16%); ascites, 8.3% (0-52%); upper gastrointestinal bleeding; 3% (0-22%); and hepatic or splenic abscess, 1.3% (0-2.5%). Treatment-related mortality was 2.4% (0-9.5%), mainly due to acute liver failure. Our meta-analysis of nine randomized controlled trials (RCTs) confirmed that TACE improves survival; but a meta-analysis of TACE versus TAE alone (3 RCTs, 412 patients) demonstrated no survival difference. Conclusions. No chemotherapeutic agent appears better than any other. There is no evidence for benefit with lipiodol. Gelatin sponge is the most used embolic agent, but PVA particles may be better. TAE appears as effective as TACE. New strategies to reduce the risk of post-TACE complications are required

  5. Preoperative embolization of nasopharyngeal angiofibromas: The role of direct percutaneous injection of cyanoacrylate glue in conjunction with particulate endovascular approach

    Directory of Open Access Journals (Sweden)

    Mohamed Abdel Hakim Osman Kasem

    2016-12-01

    Conclusion: The embolization of nasopharyngeal angiofibromas before surgery using percutaneous cyanoacrylate glue with endovascular particulate material proved to efficiently devascularize these tumours with lower blood loss during surgery and no major procedural complications.

  6. Pancreatic fistula after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis: effect of fibrin glue and polyglycolic acid felt on prophylaxis of postoperative complications.

    Science.gov (United States)

    Tsutsumi, Norifumi; Tomikawa, Morimasa; Akahoshi, Tomohiko; Kawanaka, Hirofumi; Ota, Mitsuhiko; Sakaguchi, Yoshihisa; Kusumoto, Tetsuya; Ikejiri, Koji; Hashizume, Makoto; Maehara, Yoshihiko

    2016-11-01

    This study aimed to determine the effect of fibrin glue and polyglycolic acid (PGA) felt on prevention of pancreatic fistula (PF) after laparoscopic splenectomy in patients with hypersplenism due to liver cirrhosis. Fifty consecutive patients were enrolled in this prospective study. Twenty-three patients underwent laparoscopic splenectomy with a fibrin sheet (fibrin sheet group). The sealing ability of each treatment was evaluated by an ex vivo pressure test model. Based on the results from ex vivo experiments, 27 patients received prophylaxis using fibrin glue and PGA felt (PGA with fibrin group). The primary endpoint was the incidence of PF. Significantly more (5, 22%) patients developed PF in the fibrin sheet group than in the PGA with fibrin group (0%, P = .037). Our new application of fibrin glue and PGA felt is an effective prophylactic procedure for preventing development of PF after laparoscopic splenectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. N-butyl Cyanoacrylate Glue Embolization of Arterial Networks to Facilitate Hepatic Arterial Skeletonization before Radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Samuelson, Shaun D.; Louie, John D.; Sze, Daniel Y., E-mail: dansze@stanford.edu [Stanford University School of Medicine, Division of Interventional Radiology (United States)

    2013-06-15

    Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identify subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.

  8. Research advances in sorafenib combined with orthotopic liver transplantation, radiofrequency ablation, and transarterial chemoembolization in treatment of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    ZHANG Mingjuan

    2014-08-01

    Full Text Available Hepatocellular carcinoma (HCC is one of the most common malignant tumors worldwide, and traditional surgery and chemotherapy provide limited benefit. Sorafenib, a multikinase inhibitor, was proved effective for advanced HCC in phase III clinical trial, which was a breakthrough in the treatment of HCC. In recent years, the studies on sorafenib combined with other therapies in the treatment of HCC have been conducted around the world, and inspiring results have been seen. The research advances in sorafenib combined with orthotopic liver transplantation, radiofrequency ablation, and transarterial chemoembolization in the treatment of HCC are summarized. It is thought that sorafenib combined with other anticancer therapies is expected to become a new approach of targeted therapy of HCC.

  9. Experimental Status of Exotic Mesons and the GlueX Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Daniel Carman

    2006-10-22

    One of the unanswered and most fundamental questions in physics regards the nature of the confinement mechanism of quarks and gluons in QCD. Exotic hybrid mesons manifest gluonic degrees of freedom and their spectroscopy will provide the data necessary to test assumptions in lattice QCD and the specific phenomenology leading to confinement. Within the past two decades a number of experiments have put forth tantalizing evidence for the existence of exotic hybrid mesons in the mass range below 2 GeV. This talk represents an overview of the available data and what has been learned. In looking toward the future, the GlueX experiment at Jefferson Laboratory represents a new initiative that will perform detailed spectroscopy of the light-quark meson spectrum. This experiment and its capabilities will be reviewed.

  10. Transarterial chemoembolization of liver metastases in patients with uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Huppert, P.E., E-mail: huppert@klinikum-darmstadt.d [Department of Diagnostic and Interventional Radiology, Klinikum Darmstadt, Darmstadt (Germany); Fierlbeck, G., E-mail: gerhard.fierlbeck@med.uni-tuebingen.d [Department of Dermatology, University of Tuebingen, Liebermeisterstrasse 25, D-72076 Tuebingen (Germany); Pereira, P., E-mail: philippe.pereira@slk-kliniken.d [Department of Diagnostic Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, D-72076 Tuebingen (Germany); Schanz, S., E-mail: stefan.schanz@med.uni-tuebingen.d [Department of Dermatology, University of Tuebingen, Liebermeisterstrasse 25, D-72076 Tuebingen (Germany); Duda, S.H., E-mail: stephan.duda@t-online.d [Department of Diagnostic Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, D-72076 Tuebingen (Germany); Wietholtz, H., E-mail: hubertus.wietholtz@klinikum-darmstadt.d [Department of Internal Medicine II, Klinikum Darmstadt, Darmstadt (Germany); Rozeik, C., E-mail: rozeik.christoph@klinloe.d [Department of Diagnostic and Interventional Radiology, Klinikum Darmstadt, Darmstadt (Germany); Claussen, C.D., E-mail: claus.claussen@med.uni-tuebingen.d [Department of Diagnostic Radiology, University of Tuebingen, Hoppe-Seyler-Strasse 3, D-72076 Tuebingen (Germany)

    2010-06-15

    Summary: Metastases from uveal melanoma are often confined to the liver. Palliative hepatic chemoembolization has been considered to be a reasonable treatment approach. We enrolled 14 patients with hepatic metastases from uveal melanoma into a pilot trial of transarterial chemoembolization (TACE). All patients received additional systemic immuno-chemotherapy or best supportive care. In 31 procedures 100 mg/m{sup 2} of cisplatine was continuously infused by means of a power injector preceding embolization by manual injection of polyvinyl alcohol particles. In three procedures cisplatine was replaced by 200 mg/m{sup 2} carboplatine because of increased serum creatinine levels. Tumor response was evaluated using RECIST criteria. Fourteen patients received 34 TACE's (mean: 2.4 treatments). Eight patients (57%) achieved partial response (PR), four patients (29%) had stable disease and two patients (14%) tumor progression. Median time to progression was 8.5 months (5-35 months). Median survival after first TACE was 14.5 months in responders compared to 10 months in non-responders (p = 0.18, not significant) and 11.5 months (3-69 months) in all patients. In seven patients with metastases occupying less than 25% of liver volume median survival was 17 months compared to 11 months in seven patients with tumor involvement of more than 25% (p = 0.02) with partial response rate of 86% and 29%, respectively. TACE of liver metastases from uveal melanoma is well tolerated and may prolong survival in patients with limited tumor extension.

  11. Informal uncertainty analysis (GLUE of continuous flow simulation in a hybrid sewer system with infiltration inflow – consistency of containment ratios in calibration and validation?

    Directory of Open Access Journals (Sweden)

    A. Breinholt

    2013-10-01

    Full Text Available Monitoring of flows in sewer systems is increasingly applied to calibrate urban drainage models used for long-term simulation. However, most often models are calibrated without considering the uncertainties. The generalized likelihood uncertainty estimation (GLUE methodology is here applied to assess parameter and flow simulation uncertainty using a simplified lumped sewer model that accounts for three separate flow contributions: wastewater, fast runoff from paved areas, and slow infiltrating water from permeable areas. Recently GLUE methodology has been critisised for generating prediction limits without statistical coherence and consistency and for the subjectivity in the choice of a threshold value to distinguish "behavioural" from "non-behavioural" parameter sets. In this paper we examine how well the GLUE methodology performs when the behavioural parameter sets deduced from a calibration period are applied to generate prediction bounds in validation periods. By retaining an increasing number of parameter sets we aim at obtaining consistency between the GLUE generated 90% prediction limits and the actual containment ratio (CR in calibration. Due to the large uncertainties related to spatio-temporal rain variability during heavy convective rain events, flow measurement errors, possible model deficiencies as well as epistemic uncertainties, it was not possible to obtain an overall CR of more than 80%. However, the GLUE generated prediction limits still proved rather consistent, since the overall CRs obtained in calibration corresponded well with the overall CRs obtained in validation periods for all proportions of retained parameter sets evaluated. When focusing on wet and dry weather periods separately, some inconsistencies were however found between calibration and validation and we address here some of the reasons why we should not expect the coverage of the prediction limits to be identical in calibration and validation periods in real

  12. Evaluating Uncertainty of Runoff Simulation using SWAT model of the Feilaixia Watershed in China Based on the GLUE Method

    Science.gov (United States)

    Chen, X.; Huang, G.

    2017-12-01

    In recent years, distributed hydrological models have been widely used in storm water management, water resources protection and so on. Therefore, how to evaluate the uncertainty of the model reasonably and efficiently becomes a hot topic today. In this paper, the soil and water assessment tool (SWAT) model is constructed for the study area of China's Feilaixia watershed, and the uncertainty of the runoff simulation is analyzed by GLUE method deeply. Taking the initial parameter range of GLUE method as the research core, the influence of different initial parameter ranges on model uncertainty is studied. In this paper, two sets of parameter ranges are chosen as the object of study, the first one (range 1) is recommended by SWAT-CUP and the second one (range 2) is calibrated by SUFI-2. The results showed that under the same number of simulations (10,000 times), the overall uncertainty obtained by the range 2 is less than the range 1. Specifically, the "behavioral" parameter sets for the range 2 is 10000 and for the range 1 is 4448. In the calibration and the validation, the ratio of P-factor to R-factor for range 1 is 1.387 and 1.391, and for range 2 is 1.405 and 1.462 respectively. In addition, the simulation result of range 2 is better with the NS and R2 slightly higher than range 1. Therefore, it can be concluded that using the parameter range calibrated by SUFI-2 as the initial parameter range for the GLUE is a way to effectively capture and evaluate the simulation uncertainty.

  13. Pain experience during internal spermatic vein embolization for varicocele: comparison of two cyanoacrylate glues

    Energy Technology Data Exchange (ETDEWEB)

    Heye, Sam; Maleux, Geert; Wilms, Guido [University Hospital Gasthuisberg, Department of Radiology, Leuven (Belgium)

    2006-01-01

    The purpose of this study was to evaluate possible pain sensation differences in patients after retrograde varicocele embolization either with n-butyl-(2)-cyanoacrylate (NBCA) or with n-butyl-(2)-cyanoacrylate + methacryloxysulfolane (NBCA-MS). Transcatheter varicocele embolization was performed in 64 consecutive patients (62 left, two bilateral). Embolization was done with NBCA (n=32) or NBCA-MS (n=32). Immediately after the procedure, patients were asked to evaluate pain during embolization using a visual analog scale (VAS). Statistical analysis was done with Student's t test. Mean pain score on VAS was 3.23 (range: 0-8) for NBCA and 3.28 (range 0-9) for NBCA-MS. This difference was not significant (P=0.932). Independently of the type of glue, no difference in pain sensation (P value 0.421) was found between patients younger than 18 (n=29) and patients older than 18 years of age (n=35) (younger than18, mean 3.52; older than 18, mean 3.05). No difference in mean pain experience level (P=0.323) was seen in 11 patients with vessel wall perforation (23.4%) during the procedure (3.89; range: 0-8.5) in comparison with those without perforation (mean pain sensation level: 3.13; range: 0-9). No difference in pain experience was found after transcatheter varicocele embolization either with NBCA or NBCA-MS. Age and vessel wall perforation have no influence on pain sensation independently of the type of glue. (orig.)

  14. Pain experience during internal spermatic vein embolization for varicocele: comparison of two cyanoacrylate glues

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Wilms, Guido

    2006-01-01

    The purpose of this study was to evaluate possible pain sensation differences in patients after retrograde varicocele embolization either with n-butyl-(2)-cyanoacrylate (NBCA) or with n-butyl-(2)-cyanoacrylate + methacryloxysulfolane (NBCA-MS). Transcatheter varicocele embolization was performed in 64 consecutive patients (62 left, two bilateral). Embolization was done with NBCA (n=32) or NBCA-MS (n=32). Immediately after the procedure, patients were asked to evaluate pain during embolization using a visual analog scale (VAS). Statistical analysis was done with Student's t test. Mean pain score on VAS was 3.23 (range: 0-8) for NBCA and 3.28 (range 0-9) for NBCA-MS. This difference was not significant (P=0.932). Independently of the type of glue, no difference in pain sensation (P value 0.421) was found between patients younger than 18 (n=29) and patients older than 18 years of age (n=35) (younger than18, mean 3.52; older than 18, mean 3.05). No difference in mean pain experience level (P=0.323) was seen in 11 patients with vessel wall perforation (23.4%) during the procedure (3.89; range: 0-8.5) in comparison with those without perforation (mean pain sensation level: 3.13; range: 0-9). No difference in pain experience was found after transcatheter varicocele embolization either with NBCA or NBCA-MS. Age and vessel wall perforation have no influence on pain sensation independently of the type of glue. (orig.)

  15. The GlueX Start Counter and Beam Asymmetry$\\Sigma$ in Single $\\pi^{0}$ Photoproduction

    Energy Technology Data Exchange (ETDEWEB)

    Pooser, Eric [Florida Intl Univ., Miami, FL (United States)

    2016-03-26

    The GlueX experiment aims to study meson photoproduction while utilizing the coherent bremsstrahlung technique to produce a 9 GeV linearly polarized photon beam incident on a liquid H2 target. A Start Counter detector was fabricated to properly identify the accelerator electron beam buckets and to provide accurate timing information. The Start Counter detector was designed to operate at photon intensities of up to 108 γ/s in the coherent peak and provides a timing resolution ~300 ps so as to provide successful identification of the electron beam buckets to within 99% accuracy. Furthermore, the Start Counter detector provides excellent solid angle coverage, ~ 90% of 4π hermeticity, and a high degree of segmentation for background rejection. It consists of a cylindrical array of 30 scintillators with pointed ends that bend towards the beam at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were selected as the readout system. An initial measurement of the beam asymmetry Sigma in the exclusive reaction γ$\\vec{p}$→ π0p, where π0 → γ has been carried out utilizing the GlueX spectrometer during the Spring 2015 commissioning run. The tagged photon energies ranged from 2.5≤ Eγ ≤ 3.0 GeV in the coherent peak. These measurements were then compared to the world data set and show remarkable agreement with only two hours of physics production running.

  16. Alterations in myoelectric activity of the small bowel in rabbits after transarterial embolization

    International Nuclear Information System (INIS)

    Ai Songtao; Wang Xiaolin; Gong Gaoquan; Chen Yi; Lin Genlai; Zhang Feng; Li Guoping; Liu Lingxiao

    2005-01-01

    Objective: To explore alterations in myoelectric activity of the small bowel in rabbits after transarterial embolization and provide academic basis for assessing bowel viability and management. Methods: Twenty normal rabbits were selected and divided into three groups (2 mg group, n=10; 6 mg group, n=5; control group, n=5). Members of 2 mg group were embolized with PVA 2 mg, those of 6 mg group with PVA 6 mg, and the control group with normal saline 2 ml. After microcatherization embolization, myoelectric activity of the small bowel was recorded for 24 hr using chronically implanted electrodes in conscious rabbits. Results: In 2 mg group, the frequency and the amplitude of slow wave of proximal jejunum were significantly lower in post-embolization period than pre-embolization period [(17.83±0.55) cpm vs (11.59±0.23) cpm(P 0.05) and (0.1632±0.002) mV vs (0.1606±0.003) mV (P>0.05), respectively]. Conclusions: Embolization with PVA evokes significant and passive effect on basal electrical rhythm of small bowel. It could provide academic basis for assessing bowel viability to interventional embolization. (authors)

  17. Tips of the dual-lumen microcatheter-facilitated reverse wire technique in percutaneous coronary interventions for markedly angulated bifurcated lesions.

    Science.gov (United States)

    Nomura, Tetsuya; Kikai, Masakazu; Hori, Yusuke; Yoshioka, Kenichi; Kubota, Hiroshi; Miyawaki, Daisuke; Urata, Ryota; Sugimoto, Takeshi; Keira, Natsuya; Tatsumi, Tetsuya

    2018-04-01

    In practical settings of percutaneous coronary intervention (PCI), we sometimes encounter difficulty in introducing a guidewire (GW) to the markedly angulated side branch (SB), and the reverse wire technique is considered as a last resort to overcome such a situation. We analyzed 12 cases that underwent PCI with dual-lumen microcatheter-facilitated reverse wire technique between January 2013 and July 2016. We retrospectively investigated the lesion's characteristics and the details of the PCI procedures, and discussed tips about the use of this technique. The SB that exhibits both a smaller take-off angle and a larger carina angle is considered to be the most suitable candidate for this technique. The first step of this technique involves the delivery of the reverse wire system to the target bifurcation. However, most cases exhibit significant stenosis proximal to the bifurcation, which often hampers the delivery of the reverse wire system. Because the sharply curved reverse wire system is easier to pass the stenosis as compared to the roundly curved system, we recommend a sharp curve should be adopted for this technique. On the other hand, it is sure that device delivery is much easier on the GW with a round curve as compared to that with a sharp curve. Therefore, it is important to modify the details of this procedure on a case-by-case basis according to the lesion's characteristics.

  18. The effect of different methods of transarterial chemoembolization on the angiogenesis of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Guo Dong; Xiao Enhua

    2007-01-01

    Objective: To investigate the effect of different methods of transarterial chemoembolisation (TACE) on the angiogenesis of hepatocellular carcinoma (HCC). Methods: One hundred and thirty-six HCC specimens from 136 patients were collected. Fifty-seven tumors came from patients who were treated only by surgery (group A), 11 tumors from patients who were treated by transarterial chemoperfusion before surgery (group B), 68 tumors from patients who were treated by TACE before surgery (group TACE ), respectively. And the TACE group was classified into 3 sub-groups: iodinated oil + chemotherapeutics for 33 cases (group C), iodinated oil + chemotherapeutics + gelatin sponge for 23 cases (group D), iodinated oil + chemotherapeutics + gelatin sponge + absolute alcohol for 12 cases (group E), respectively. Also, the tumors of TACE were divided into 4 groups according to an elapse between the last TACE therapy and the surgery. They were group ≤30 days (n=24), group 31- 60 days (n=25), group 61-90 days (n=13), group > 90 days (n=6), respectively. The pathological sections were stained by immunohistochemical method. The microvessels were marked by CD31. And the stained cells were counted under the light microscope. Results: The mean of microvessels density (MVD) were (44±18), (48±23), (55±22), respectively. The mean of MVD in group TACE was significantly higher than that in group A (t=-2.897, P 0.05). The mean of MVD in group C, group D and group E were (56 ± 22), (54 ± 24), (52 ± 19), respectively. The differences of the mean of MVD were not statistically significant among the three groups. (F=0.152, P>0.05). The mean of MVD in group ≤ 30 days, group 31-60 days, group 61-90 days, group >90 days were (50 ± 19), (55 ± 24), (62 ± 29), (53 ± 10), respectively. The mean of MVD of group A was significantly lower than those of 4 groups( group A was served as a control group as they were supposed as treated by TACE after 0 day) (P>0.05). There was significant differences

  19. Transarterial embolization for the management of hemarthrosis of the knee

    International Nuclear Information System (INIS)

    Waldenberger, P.; Chemelli, A.; Hennerbichler, A.; Wick, M.; Freund, M.C.; Jaschke, W.; Thaler, M.; Chemelli-Steingruber, I.E.

    2012-01-01

    Background: The purpose of this retrospective study was to evaluate transarterial catheter embolization (TAE) for the management of hemarthrosis of the knee in 35 patients treated at two different hospitals. Methods: From June 1998 through January 2011, 35 patients (22 men and 13 women, mean age 57 years) underwent TAE for hemarthrosis of the knee using polyvinyl alcohol particles (PVA particles), multi-curled 0.018 in. microcoils or a combination of both. In one patient a detachable microcoil was used. Hemarthrosis developed after arthroscopy in 9, after trauma in 3, after arthroplasty in 18 and after sepsis in 2 patients. 2 patients had severe gonarthrosis and in one patient hemarthrosis was due to Marfan's syndrome. Angiographies showed abnormal and increased vasculature in 23 patients, one or more pseudoaneurysms in 8 and arterio-venous fistula in 2 patients. One patient showed both, pseudoaneurysm and hypervascularization and another one pseudoaneurysm and arterio-venous fistula. Results: Technical success was achieved in 100%. None of the patients developed procedure-related complications such as periarticular skin- or tissue necrosis, including a patient who underwent TAE of two different bleeding sources in two consecutive sessions. Clinical success was 93.4%. Two patients showed recurrent swelling of the knee, 377 and 824 days after TAE respectively. However, only one of them required secondary TAE because of abnormal and increased vasculature. Conclusions: In our view, TAE is the treatment of choice for the management of hemarthrosis of the knee. It is an effective and minimally invasive technique with very low complication rates

  20. Transarterial embolization for the management of hemarthrosis of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Waldenberger, P., E-mail: peter.waldenberger@bhs.at [Department of Radiology, Hospital of the Sisters of Charity, Linz (Austria); Chemelli, A., E-mail: andreas.chemelli@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Hennerbichler, A., E-mail: alfred.hennerbichler@i-med.ac.at [Department of Trauma Surgery, Innsbruck Medical University (Austria); Wick, M., E-mail: marius.wick@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Freund, M.C., E-mail: martin.freund@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Jaschke, W., E-mail: werner.jaschke@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria); Thaler, M., E-mail: martin.thaler@i-med.ac.at [Department of Orthopedic Surgery, Innsbruck Medical University (Austria); Chemelli-Steingruber, I.E., E-mail: iris.chemelli-steingruber@i-med.ac.at [Department of Radiology, Innsbruck Medical University (Austria)

    2012-10-15

    Background: The purpose of this retrospective study was to evaluate transarterial catheter embolization (TAE) for the management of hemarthrosis of the knee in 35 patients treated at two different hospitals. Methods: From June 1998 through January 2011, 35 patients (22 men and 13 women, mean age 57 years) underwent TAE for hemarthrosis of the knee using polyvinyl alcohol particles (PVA particles), multi-curled 0.018 in. microcoils or a combination of both. In one patient a detachable microcoil was used. Hemarthrosis developed after arthroscopy in 9, after trauma in 3, after arthroplasty in 18 and after sepsis in 2 patients. 2 patients had severe gonarthrosis and in one patient hemarthrosis was due to Marfan's syndrome. Angiographies showed abnormal and increased vasculature in 23 patients, one or more pseudoaneurysms in 8 and arterio-venous fistula in 2 patients. One patient showed both, pseudoaneurysm and hypervascularization and another one pseudoaneurysm and arterio-venous fistula. Results: Technical success was achieved in 100%. None of the patients developed procedure-related complications such as periarticular skin- or tissue necrosis, including a patient who underwent TAE of two different bleeding sources in two consecutive sessions. Clinical success was 93.4%. Two patients showed recurrent swelling of the knee, 377 and 824 days after TAE respectively. However, only one of them required secondary TAE because of abnormal and increased vasculature. Conclusions: In our view, TAE is the treatment of choice for the management of hemarthrosis of the knee. It is an effective and minimally invasive technique with very low complication rates.

  1. Intercostal artery pseudoaneurysm complicating corrosive acid poisoning: Diagnosis with CT and treatment with transarterial embolisation

    Directory of Open Access Journals (Sweden)

    M V Chalapathi Rao

    2014-01-01

    Full Text Available Pseudoaneurysms of intercostal artery are very rare. All the published cases have been caused by trauma, either iatrogenic or otherwise. They can cause hemothorax, retroperitoneal hemorrhage or can present as pulsatile chest mass. Doppler ultrasound, contrast-enhanced CT and conventional angiogram can accurately diagnose this condition. All the reported cases have been treated by embolisation, stenting or surgery. We report an unusual case of intercostal artery pseudoaneurysm arising as a complication of corrosive poisoning presenting with hematemesis and treated by glue embolisation. The authors believe this to be the first case of intercostal artery pseudoaneurysm that is non-traumatic, complicating corrosive poisoning and presenting with hematemesis.

  2. A comparative in vitro study of the viability of human keratinocytes grown on irradiated human amnion membrane and fibrin glue scaffolds

    International Nuclear Information System (INIS)

    Dorai, A.A.; Lim, C.K.; Azman, W.S.; Halim, A.S.

    2008-01-01

    Full text: The dried irradiated human amnion membrane has been used as a biological dressing for various clinical conditions. Being another biological membrane its potential as a scaffold to grow human keratinocytes is not known yet. To compare the growth patterns and cell viability of keratinocytes using fibrin glue and air dried amnion membrane as a scaffold. Keratinocytes were obtained from skin samples of six patients undergoing elective surgery. Fibrin glue (Tisseel, Baxter ) was diluted and used to coat the wells. Human dried amnion membrane was obtained and placed into the 24 well plates. Keratinocytes were seeded into the fibrin and amnion scaffold. Cell viability assay (MTT) was performed after 24, 48 and 72 hours. Finally the measurements were done by the Enzyme-Linked Immunosorbent Assay (ELISA) reader at 570 nm. Six patients consented for the study. The cells growing on the amnion scaffold showed a decreasing trend (20.67%, 17.94% and 16.78% respectively for 24, 48 and 72 hours). The cells growing on the fibrin scaffold showed a steady increase in number at 24, 48 and 72 hours (73.03%, 74.12% and 79.66%). The percentage of growth of normal human keratinocytes were significantly greater in the fibrin scaffold group (Mann - Whitney p = 0.002) for 24, 48 and 72 hours. The air dried irradiated human amnion membrane can be used as a scaffold to grow keratinocytes but however the growth pattern does not sustain with time. Fibrin glue supports the growth of human keratinocytes and shows an increasing pattern of growth with time. (Author)

  3. A metastatic adrenal tumor from a hepatocellular carcinoma: combination therapy with transarterial chemoembolization and radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Jin; Cho, Yun Ku; Ahn, Yong Sik; Kim, Mi Young [Seoul Veterans Hospital, Seoul (Korea, Republic of)

    2007-07-15

    The adrenal gland is the second most common site of metastasis from a hepatocellular carcinoma (HCC). Radiofrequency ablation (RFA) for these tumors has been reported to be a potentially effective alternative to an adrenalectomy, especially for inoperable patients. However, for intermediate or large adrenal tumors, combination therapy of transarterial chemoembolization (TACE) and RFA can be attempted as it may reduce the heat sink effect. A 74-year-old patient presented with abdominal discomfort. Abdominal CT images revealed a 5.0 cm sized right adrenal mass. A percutaneous biopsy of the adrenal mass revealed a metastatic hepatocellular carcinoma. TACE was performed on the adrenal mass. However, a one-month follow-up CT image revealed a residual viable tumor. RFA was performed for the adrenal tumor six weeks after the TACE. No procedure-related major complications were noted. The serum alpha-fetoprotein level had also been normalized after the treatment, and 10-month follow-up CT images showed no definite evidence of viable adrenal tumor.

  4. Delayed postpartum haemorrhage secondary to a ruptured uterine artery pseudo-aneurysm, successfully treated by transarterial embolisation.

    Science.gov (United States)

    Moatti, Zoe; Nisner, Tamar; Saini, Ashish; Karoshi, Mahantesh

    2011-12-01

    A 29-year-old woman (gravida 1, para 1) had an uneventful first pregnancy and a delivery by emergency caesarean section at term. The caesarean section was complicated by a massive obstetric haemorrhage of 5000 ml. After closure, an immediate re-laparotomy was indicated due to heavy vaginal bleeding. The site of bleeding was identified as an extension of the uterine incision, and was sutured. She was stabilised by transfusion of blood and blood products in the intensive therapy unit, and discharged 5 days later. The patient was re-admitted 6 weeks later with brisk, painless vaginal bleeding, passing large clots from a well-contracted uterus. Her haemoglobin decreased from 11.8 to 7.8 g/dl overnight. In view of her history, an urgent CT angiogram was performed, which revealed the presence of a pseudo-aneurysm arising from the left uterine artery. This was successfully occluded by transarterial embolisation, obviating the need for further surgical exploration.

  5. Transarterial embolization of an aortoesophageal fistula secondary to placement of a palliative esophageal stent: a case report

    International Nuclear Information System (INIS)

    Cha, Eun Young; Shin, Ji Hoon; Yoon, Hyun Ki; Ko, Gi Young; Sung, Kyu Bo; Kwong, Dong Il; Song, Ho Young

    2007-01-01

    An aortoesophageal fistula is a rare condition caused by descending aortic diseases such as an aneurysm, foreign body ingestion, esophageal malignancy, and ulcers. An aortoesophageal fistula as a complication of esophageal stent placement is extremely rare and only one case had been reported previously worldwide, to the best of our knowledge. We report a case of an aortoesophageal fistula in a 64-year-old man who previously underwent palliative esophageal stent placement due to local tumor recurrence after a total gastrectomy of vanced gastric cancer in the cardia. The fistula was occluded by glue embolization

  6. Transarterial chemoembolization through collateral vessels in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hye; Han, Joon Koo; Chung, Jin Wook; Park, Jae Hyung; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-11-15

    We performed 70 procedures of transarterial chemoembolization (TAE) through extrahepatic collateral vessels (n=27) or parasitic feeders (n=18) in 45 hepatocellular carcinoma patients. The collaterals developed after interruption of the hepatic artery due to repeated TAE (n=17), surgical ligation (n=7)and primary celiac occlusion (n=3). Radiologic findings suggest the existence of parasitic or collateral supply for hepatocellular carcinoma were 1) a focal defect of Lipiodol retention on CT or plain film after TAE via the hepatic artery, 2) dilated and tortuous vessels around the mass on angiography, 3) persistent elevation of the level of serum alpha-fetoprotein or continuous clinical symptoms in spite of sufficient devascularization of the tumor via the hepatic artery, and 4) radiological findings of direct invasion into adjacent organ. The sites of the catheter placement were the inferior phrenic artery(n=19), omental branches(n=16), periportal collaterals (n=6), pancreaticodenal arcade (n=3), gastroduodenal artery(n=3), internal mammary artery (n=2), intercosal artery (n=2), lateral thoracic artery (n=1), bronchial artery (n=1), and colic branches (n=1). Masses feeded by the inferior phrenic and chest wall collaterals were usually located at the dome area of the liver, and the omental and gastroduodenal collaterals developed in the masses located at the inferior tip of the liver. After TAE via collateral vessels, 37 patients underwent follow-up study. In 18 cases(48%), the tumor favorably responded to TAE. Specific complications of collateral TAE were epigastric soreness (n=10), severe shoulder pain (n=4), and embolization of the spinal artery during embolization through the intercostal artery (n=1). In conclusion, various extrahepatic collateals are important alternative or addition routes for effective chemoembolization in patients with advanced hepatoma, and early recognition of the parasitic supply and the effort to perform TAE via collaterals is very

  7. Transarterial chemoembolization through collateral vessels in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kim, Ji Hye; Han, Joon Koo; Chung, Jin Wook; Park, Jae Hyung; Han, Man Chung

    1993-01-01

    We performed 70 procedures of transarterial chemoembolization (TAE) through extrahepatic collateral vessels (n=27) or parasitic feeders (n=18) in 45 hepatocellular carcinoma patients. The collaterals developed after interruption of the hepatic artery due to repeated TAE (n=17), surgical ligation (n=7)and primary celiac occlusion (n=3). Radiologic findings suggest the existence of parasitic or collateral supply for hepatocellular carcinoma were 1) a focal defect of Lipiodol retention on CT or plain film after TAE via the hepatic artery, 2) dilated and tortuous vessels around the mass on angiography, 3) persistent elevation of the level of serum alpha-fetoprotein or continuous clinical symptoms in spite of sufficient devascularization of the tumor via the hepatic artery, and 4) radiological findings of direct invasion into adjacent organ. The sites of the catheter placement were the inferior phrenic artery(n=19), omental branches(n=16), periportal collaterals (n=6), pancreaticodenal arcade (n=3), gastroduodenal artery(n=3), internal mammary artery (n=2), intercosal artery (n=2), lateral thoracic artery (n=1), bronchial artery (n=1), and colic branches (n=1). Masses feeded by the inferior phrenic and chest wall collaterals were usually located at the dome area of the liver, and the omental and gastroduodenal collaterals developed in the masses located at the inferior tip of the liver. After TAE via collateral vessels, 37 patients underwent follow-up study. In 18 cases(48%), the tumor favorably responded to TAE. Specific complications of collateral TAE were epigastric soreness (n=10), severe shoulder pain (n=4), and embolization of the spinal artery during embolization through the intercostal artery (n=1). In conclusion, various extrahepatic collateals are important alternative or addition routes for effective chemoembolization in patients with advanced hepatoma, and early recognition of the parasitic supply and the effort to perform TAE via collaterals is very

  8. Autologous plasma rich in growth factors in the prevention of severe bleeding after teeth extractions in patients with bleeding disorders: a controlled comparison with fibrin glue

    Science.gov (United States)

    Cocero, Nadia; Pucci, Fabrizio; Messina, Maria; Pollio, Berardino; Mozzati, Marco; Bergamasco, Laura

    2015-01-01

    Background Dental extractions in haemophiliacs may cause secondary bleeding, requiring repeated surgical and haematological interventions. As a local haemostatic, fibrin glue has recognised efficacy but, as a plasma-derived product, it carries the risk of viral infections. We, therefore, compared fibrin glue with an autologous haemostatic, plasma rich in growth factors (PRGF), in a controlled trial. Material and methods One hundred and twenty patients with different blood disorders were randomised into two cohorts to undergo dental extraction procedures without hospitalisation. Prior to the extractions, patients underwent systemic haematological treatment. Complications were defined as secondary bleeding after the 7-day follow-up period or protracting after the repair procedure. Results There were 106 extractions (7 retained 3rd molars) in the group managed with fibrin glue: secondary bleeding affected 3/60 patients (5%) on the third day after extraction and necessitated additional surgery and systemic treatment (in one case the procedure had to be repeated on the 7th day). In the PRGF arm there were 98 extractions (23 retained 3rd molars): secondary bleeding affected two patients (3.3%) on the first day after extraction and was arrested with surgery without systemic treatment. Four out of the five secondary bleeds occurred in patients with haemophilia A. Concomitant diabetes or liver disease significantly increased the bleeding risk. Discussion The bleeding rates in the study and control arm prove that PRGF works as well as fibrin glue as a local haemostatic. Further assets are that PRGF has autologous origin, does not require additional systemic treatment in post-extraction repair surgery, is associated with an earlier onset of neo-angiogenesis and, overall, can reduce patients’ distress and costs to the health system. PMID:25369587

  9. Treatment Outcome Following Transarterial Chemoembolization in Advanced Bone and Soft Tissue Sarcomas

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Chunyu; Wang, Jianbo, E-mail: a602131499@163.com [Shanghai Jiaotong University Affiliated Sixth People’s Hospital, Department of Radiology (China); Wang, Yonggang [Shanghai Jiaotong University Affiliated Sixth People’s Hospital, Department of Oncology (China); Zhao, Jungong; Zhu, Yueqi; Ma, Xu; Zhou, Jia [Shanghai Jiaotong University Affiliated Sixth People’s Hospital, Department of Radiology (China); Yan, Xuebing [Shanghai Jiaotong University Affiliated Sixth People’s Hospital, Department of General Surgery (China)

    2016-10-15

    PurposeTransarterial chemoembolization (TACE) is used to treat unresectable bone and soft tissue sarcoma (STS) and as a pre-surgical adjuvant treatment. However, its efficiency for advanced STS is undetermined. This study evaluated TACE’s efficiency in treating advanced STS and prognostic factors for patient survival.Materials and MethodsWe enrolled 39 patients with unresectable STS who underwent TACE as an alternative treatment during 2010–2014, with overall survival (OS) as the primary end point. Cancer pain was evaluated by visual analogue scores (VAS) before and after TACE procedures. Factors that affect survival were evaluated by multivariate analyses (Cox proportional hazard model).ResultsMean OS after TACE was 23.7 ± 2.1 months, with 1-year OS 71.5 %, 2-year OS 45.8 %, and 3-year OS 32.5 %. Lesion number and tumor stage were key predictors of survival. TACE was found to decrease cancer pain VAS and increase relapse interval. Size of polyvinyl alcohol (PVA) particle diameter (P = 0.03) and imaging response (P = 0.044) were also found to affect relapse interval.ConclusionTACE was an effective treatment for advanced STS, with a 32.5 % 3-year OS rate, and led to lower cancer pain VAS and longer relapse intervals than chemoinfusion only. Smaller PVA particles are preferable during the TACE procedure.

  10. Highly Stretchable, Biocompatible, Striated Substrate Made from Fugitive Glue

    Directory of Open Access Journals (Sweden)

    Wei Li

    2015-06-01

    Full Text Available We developed a novel substrate made from fugitive glue (styrenic block copolymer that can be used to analyze the effects of large strains on biological samples. The substrate has the following attributes: (1 It is easy to make from inexpensive components; (2 It is transparent and can be used in optical microscopy; (3 It is extremely stretchable as it can be stretched up to 700% strain; (4 It can be micro-molded, for example we created micro-ridges that are 6 μm high and 13 μm wide; (5 It is adhesive to biological fibers (we tested fibrin fibers, and can be used to uniformly stretch those fibers; (6 It is non-toxic to cells (we tested human mammary epithelial cells; (7 It can tolerate various salt concentrations up to 5 M NaCl and low (pH 0 and high (pH 14 pH values. Stretching of this extraordinary stretchable substrate is relatively uniform and thus, can be used to test multiple cells or fibers in parallel under the same conditions.

  11. Management of a complicated pulmonary fistula caused by lung cancer using a fibrin glue-soaked polyglycolic acid sheet covered with an intercostal muscle flap.

    Science.gov (United States)

    Maniwa, Tomohiro; Kaneda, Hiroyuki; Saito, Yukihito

    2009-06-01

    Pulmonary fistulas caused by tumours are very fragile and difficult to suture directly. It is impossible to close pulmonary fistulas with tissue sealants when massive air leakage occurs in the low pressure of the respiratory tract. A 73-year-old man with a pneumothorax caused by lung cancer had suffered a persistent massive air leakage for more than one month. We used a fibrin glue-soaked polyglycolic acid (PGA) sheet for sealing the complicated fistula. In addition, the visceral pleura of the fistula was wrapped with the pedicle of an intercostal muscle (ICM) flap to prevent massive air leakage. The pneumothorax did not reappear after surgery. Thus, a fibrin glue-soaked PGA sheet covered with an ICM flap was effective for sealing an intractable air-leaking fistula caused by lung cancer.

  12. From glue to gasoline: how competition turns perspective takers unethical.

    Science.gov (United States)

    Pierce, Jason R; Kilduff, Gavin J; Galinsky, Adam D; Sivanathan, Niro

    2013-10-01

    Perspective taking is often the glue that binds people together. However, we propose that in competitive contexts, perspective taking is akin to adding gasoline to a fire: It inflames already-aroused competitive impulses and leads people to protect themselves from the potentially insidious actions of their competitors. Overall, we suggest that perspective taking functions as a relational amplifier. In cooperative contexts, it creates the foundation for prosocial impulses, but in competitive contexts, it triggers hypercompetition, leading people to prophylactically engage in unethical behavior to prevent themselves from being exploited. The experiments reported here establish that perspective taking interacts with the relational context--cooperative or competitive--to predict unethical behavior, from using insidious negotiation tactics to materially deceiving one's partner to cheating on an anagram task. In the context of competition, perspective taking can pervert the age-old axiom "do unto others as you would have them do unto you" into "do unto others as you think they will try to do unto you."

  13. Transarterial Re-188 labeled Lipiodol therapy in cases of inoperable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kumar, Ajay; Pant, G.S.; Bandopadhyaya, G.P.; Bal, C.S.; Srivastava, D.N.; Acharya, S.K.; Pandey, G.K.; DattaGupta, S.; Sundaram, K.R.; Zanzonicog, Pat; Sundaram, Felix X.; Padhy, A.K.

    2004-01-01

    Full text: Most of the patients of hepatocellular carcinoma (HCC) present late with inoperable disease, cirrhosis of the liver and sometimes with portal vein thrombosis. In these circumstances, chemoembolisation is not possible. Similarly, if tumor is not accessible percutaneously, percutaneous ablative procedures are also ruled out. Such patients can be offered internal radionuclide therapy. In the internal radionuclide therapy, it is desirable to deliver the maximum possible radiation to the tumor, while protecting the critical organs such as normal liver parenchyma, lungs and the bone marrow (for which critical levels of radiation doses are predetermined as 30, 12 and 1.5 Gy, respectively). This is possible with individual dosimetry, by which radiation-absorbed dose/MBq to the various organs including the tumor is calculated and the 'maximum tolerated activity (MTA)', which can be safely administered to the patient, is estimated. However, this MTA should be able to deliver enough radiation to the tumor to ablate it completely (considered to be 80-100 Gy). We conducted trans-arterial Re-188 lipiodol therapy in patients with inoperable HCC after calculating MTA with individual dosimetry, in a multi-centric trial conducted by IAEA, and tried to evaluate whether calculated MTA could deliver tumoricidal radiation dose. With a transarterially injected scout dose (185 MBq) of Re-188, radiation absorbed dose to above mentioned organs including tumor were calculated in ten patients after acquiring planar gamma camera images, using conjugate view method (images taken up to 3 hrs post-injection along with a standard source) and performing first-order corrections for scatter (by taking images both in photopeak and scatter window) and attenuation (by taking a flood source and a transmission scan of the patents prior to the administration of Re-188). Images were acquired on gamma camera(Siemens-ORBITOR or GE- Millennium VG) with high/medium-energy collimator and radiation

  14. Evaluation of the relationship between hepatocellular carcinoma location and transarterial chemoembolization efficacy.

    Science.gov (United States)

    Miki, Izumi; Murata, Satoru; Uchiyama, Fumio; Yasui, Daisuke; Ueda, Tatsuo; Sugihara, Fumie; Saito, Hidemasa; Yamaguchi, Hidenori; Murakami, Ryusuke; Kawamoto, Chiaki; Uchida, Eiji; Kumita, Shin-Ichiro

    2017-09-21

    To evaluate the relationship between the location of hepatocellular carcinoma (HCC) and the efficacy of transarterial chemoembolization (TACE). We evaluated 115 patients (127 nodules), excluding recurrent nodules, treated with TACE between January 2011 and June 2014. TACE efficacy was evaluated according to mRECIST. The HCC location coefficient was calculated as the distance from the central portal portion to the HCC center (mm)/liver diameter (mm) on multiplanar reconstruction images rendered (MPR) to visualize bifurcation of the right and left branches of the portal vein and HCC center. The HCC location coefficient was compared between complete response (CR) and non-CR groups in Child-Pugh grade A and B patients. The median location coefficient of HCC among all nodules, the right lobe, and the medial segment was significantly higher in the CR group than in the non-CR group in the Child-Pugh grade A patients (0.82 vs 0.62, P location coefficient of the HCC in the lateral segment between in the CR and in the non-CR groups (0.67 vs 0.65, P > 0.05). On the other hand, in the Child-Pugh grade B patients, the HCC median location coefficient in each lobe and segment was not significantly different between in the CR and in the non-CR groups. Improved TACE efficacy may be obtained for HCC in the peripheral zone of the right lobe and the medial segment in Child-Pugh grade A patients.

  15. Research advances in Huai′er granules combined with transarterial chemoembolization in treatment of hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    DONG Deshuo

    2017-10-01

    Full Text Available Hepatocellular carcinoma (HCC has an insidious onset and when a confirmed diagnosis is made, most patients lose the chance for surgery and are given transarterial chemoembolization (TACE as palliative treatment. However, repeated TACE may lead to overexpression of hypoxia-inducible factor 1α (HIF-1α and vascular endothelial growth factor (VEGF, liver injury, and reduced immune function and has poor long-term efficacy. The introduction of Huai′er granules may help to change the current status. Studies in China and foreign countries have shown that Huai′er granules exert a remarkable anti-tumor effect by blocking cell cycle, inducing cell apoptosis, inhibiting cell proliferation and invasion, and blocking the hepatitis B-hepatocellular carcinoma pathway. Meanwhile, as an adjuvant drug for HCC, Huai′er granules cover the shortcomings of TACE from multiple aspects and can effectively inhibit the overexpression of HIF-1α and VEGF, improve liver injury and immunity, enhance the effect of chemotherapy drugs, and reverse drug resistance. Many clinical studies have confirmed the remarkable advantages of Huai′er granules combined with TACE, and their synergistic effect helps to enhance anti-tumor effect and improve short- and long-term survival rates.

  16. Sustained multiple organ ischaemia after transarterial chemoembolization with drug-eluting beads for hepatocellular carcinoma.

    Science.gov (United States)

    Kim, Young Woon; Kwon, Jung Hyun; Nam, Soon Woo; Jang, Jeong Won; Jung, Hyun Suk; Shin, Yu Ri; Park, Eun Su; Shim, Dong Jae

    2018-02-01

    Transarterial chemoembolization (TACE) with drug-eluting beads (DC beads) may enhance drug delivery to tumours and reduce systemic toxicity. TACE with DC beads leads to significantly fewer serious side-effects compared with conventional TACE. A 66-year-old man with hepatocellular carcinoma (HCC) complained of continuous abdominal pain 1 month after TACE with DC beads. At the time of TACE, angiography revealed severe stenosis of both hepatic arteries. The diagnostic work up on admission suggested severe bile duct injury with regional bile duct dilatation, segmental liver and spleen infarction, necrotizing pancreatitis, as well as gastric and duodenal ulcers. The pathology specimens of the duodenum contained DC beads that had passed through small vessels in the connective tissue. The patient's condition appeared to improve after 2 weeks of antibiotic treatment and supportive care, but new multifocal liver and spleen infarction subsequently developed. After 2 months, he was well enough to be discharged. His HCC partially responded to the TACE with DC beads but eventually progressed and he died after 11 months. The present case report highlights unexpected ongoing multiple organ ischaemia in a 66-year-old man treated for HCC using TACE with DC beads. The use of TACE with DC beads should be carefully considered in patients with vascular strictures or aberrant blood supply.

  17. Outcome of transarterial chemoembolization-based multi-modal treatment in patients with unresectable hepatocellular carcinoma.

    Science.gov (United States)

    Song, Do Seon; Nam, Soon Woo; Bae, Si Hyun; Kim, Jin Dong; Jang, Jeong Won; Song, Myeong Jun; Lee, Sung Won; Kim, Hee Yeon; Lee, Young Joon; Chun, Ho Jong; You, Young Kyoung; Choi, Jong Young; Yoon, Seung Kew

    2015-02-28

    To investigate the efficacy and safety of transarterial chemoembolization (TACE)-based multimodal treatment in patients with large hepatocellular carcinoma (HCC). A total of 146 consecutive patients were included in the analysis, and their medical records and radiological data were reviewed retrospectively. In total, 119 patients received TACE-based multi-modal treatments, and the remaining 27 received conservative management. Overall survival (P<0.001) and objective tumor response (P=0.003) were significantly better in the treatment group than in the conservative group. After subgroup analysis, survival benefits were observed not only in the multi-modal treatment group compared with the TACE-only group (P=0.002) but also in the surgical treatment group compared with the loco-regional treatment-only group (P<0.001). Multivariate analysis identified tumor stage (P<0.001) and tumor type (P=0.009) as two independent pre-treatment factors for survival. After adjusting for significant pre-treatment prognostic factors, objective response (P<0.001), surgical treatment (P=0.009), and multi-modal treatment (P=0.002) were identified as independent post-treatment prognostic factors. TACE-based multi-modal treatments were safe and more beneficial than conservative management. Salvage surgery after successful downstaging resulted in long-term survival in patients with large, unresectable HCC.

  18. Synthetic spider silk fibers spun from Pyriform Spidroin 2, a glue silk protein discovered in orb-weaving spider attachment discs.

    Science.gov (United States)

    Geurts, Paul; Zhao, Liang; Hsia, Yang; Gnesa, Eric; Tang, Simon; Jeffery, Felicia; La Mattina, Coby; Franz, Andreas; Larkin, Leah; Vierra, Craig

    2010-12-13

    Spider attachment disc silk fibers are spun into a viscous liquid that rapidly solidifies, gluing dragline silk fibers to substrates for locomotion or web construction. Here we report the identification and artificial spinning of a novel attachment disc glue silk fibroin, Pyriform Spidroin 2 (PySp2), from the golden orb weaver Nephila clavipes . MS studies support PySp2 is a constituent of the pyriform gland that is spun into attachment discs. Analysis of the PySp2 protein architecture reveals sequence divergence relative to the other silk family members, including the cob weaver glue silk fibroin PySp1. PySp2 contains internal block repeats that consist of two subrepeat units: one dominated by Ser, Gln, and Ala and the other Pro-rich. Artificial spinning of recombinant PySp2 truncations shows that the Ser-Gln-Ala-rich subrepeat is sufficient for the assembly of polymeric subunits and subsequent fiber formation. These studies support that both orb- and cob-weaving spiders have evolved highly polar block-repeat sequences with the ability to self-assemble into fibers, suggesting a strategy to allow fiber fabrication in the liquid environment of the attachment discs.

  19. Endovascular Treatment of Pseudoaneurysm of the Common Hepatic Artery with Intra-aneurysmal Glue (N-Butyl 2-Cyanoacrylate) Embolization

    International Nuclear Information System (INIS)

    Garg, Ashwin; Banait, Swati; Babhad, Sudeep; Kanchankar, Niraj; Nimade, Pradeep; Panchal, Chintan

    2007-01-01

    A 40-year-old man, a chronic alcoholic, presented with acute epigastric pain. Selective celiac arteriography showed a pseudoaneurysm arising from the common hepatic artery. We hereby describe a technical innovation where complete pseudoaneurysm exclusion was seen after intra-aneurysmal N-butyl 2-cyanoacrylate (glue) injection with preservation of antegrade hepatic arterial flow and conclude that intra-aneurysmal liquid injection may have potential as a therapeutic option to reconstruct a defective vessel wall and thereby maintain the antegrade flow

  20. Analysis of the η(548) ->π+π-π0 and η'(958) ->π+π- η channels using a 8-9 GeV tagged photon beam for the GlueX Experiment

    Science.gov (United States)

    Beattie, Tegan; Papandreou, Zisis; Stevens, Justin; GlueX Collaboration

    2016-09-01

    The primary goal of the GlueX experiment is to conduct a definitive mapping of states in the light meson sector with an emphasis on searching for exotic hybrid mesons as evidence of gluonic excitations. The experiment, housed in the Hall-D facility at Jefferson Lab following its accelerator upgrade to 12 GeV, is now entering the physics data taking phase. The η(548) and η'(958) mesons are two of the richest unflavoured light mesons readily available at GlueX energies for studying resonances. Many other light mesons have decay channels involving the η mesons with significant branching ratios, and πη / πη' resonances are among the top contenders for possibly-accessible exotic and hybrid resonances which GlueX aims to study. As such, the ability to reconstruct pure η/η' samples and analyze their decays is of utmost importance for understanding future work on more complicated analyses. Preliminary analysis results from commissioning data will be presented. This work was supported by NSERC Grant SAPJ-326516 and Jefferson Science Associates, LLC, who operates Jefferson Lab under U.S. DOE Contract No. DE-AC05-06OR23177.

  1. Effects of diode laser welding with dye-enhanced glue on tensile strength of sutures commonly used in urology.

    Science.gov (United States)

    Kirsch, A J; Chang, D T; Kayton, M L; Libutti, S K; Connor, J P; Hensle, T W

    1996-01-01

    Tissue welding using laser-activated protein solders may soon become an alternative to sutured tissue approximation. In most cases, approximating sutures are used both to align tissue edges and provide added tensile strength. Collateral thermal injury, however, may cause disruption of tissue alignment and weaken the tensile strength of sutures. The objective of this study was to evaluate the effect of laser welding on the tensile strength of suture materials used in urologic surgery. Eleven types of sutures were exposed to diode laser energy (power density = 15.9 W/cm2) for 10, 30, and 60 seconds. Each suture was compared with and without the addition of dye-enhanced albumin-based solder. After exposure, each suture material was strained (2"/min) until ultimate breakage on a tensometer and compared to untreated sutures using ANOVA. The strength of undyed sutures were not significantly affected; however, violet and green-dyed sutures were in general weakened by laser exposure in the presence of dye-enhanced glue. Laser activation of the smallest caliber, dyed sutures (7-0) in the presence of glue caused the most significant loss of tensile strength of all sutures tested. These results indicate that the thermal effects of laser welding using our technique decrease the tensile strength of dyed sutures. A thermally resistant suture material (undyed or clear) may prevent disruption of wounds closed by laser welding techniques.

  2. Boll weevil within season and off-season activity monitored using a pheromone-and-glue reusable tube trap

    Directory of Open Access Journals (Sweden)

    Robério Carlos dos Santos Neves

    Full Text Available ABSTRACT: The boll weevil colonizes cotton fields as early as cotton squaring, causing significant losses due to feeding and protected development inside fruiting structures throughout crop phenology. Successful control depends on control of adults and their accurate detection when they colonize the crops. The commercial trap and boll weevil attract-and-control tubes (BWACT are the only available tools to monitor and attract-and-kill boll weevil, despite limitation in efficacy, and insecticide in BWACT is not allowed in organic production. A grandlure-and-glue reusable and insecticide-free tube (GGT made with polyvinyl chloride tube, smeared with entomological glue, and lured with pheromone was tested to detect boll weevil activity across various seasons. Boll weevil showed activity during growing season and off-season from 2009 to 2012 in the Semiarid and with higher numbers captured in GGT in comparisons to commercial traps. GGT was able to detect early weevils in the field right after planting. Further, the overall averages resulted in 34-, 16.8-, and 7.5-times more weevils captured in GGTs compared to the traps during stalk destruction in the Semiarid 2011 and Cerrado season 2012/13 and during the harvesting period in the Cerrado season 2011/12, respectively. Therefore, boll weevils were captured actively during season and off-season and early captures obtained in GGT compared to traps showed a better correlation between captures and square damage.

  3. Long-Term Palliative Effect of Stenting in Gastric Outlet Obstruction Due to Transarterial Chemoembolization with Yttrium-90 in a Patient with Metastatic Neuroendocrine Tumor

    Directory of Open Access Journals (Sweden)

    Erkan Caglar

    2016-09-01

    Full Text Available Internal radioembolization with yttrium-90 is a promising treatment method, predominantly for liver tumors. However, the shifting of yttrium-90-loaded spherules into the arteries and veins that supply the duodenum and stomach, leading to ulceration, hemorrhage, perforation, and outlet obstruction of these organs, is one of the major undesirable consequences of this technique. We report a case of gastric outlet obstruction (GOO due to antropyloric stenosis with ulceration, edema, and inflammation following transarterial yttrium-90 treatment for a metastatic neuroendocrine tumor in a 58-year-old man. Stenting was used for palliation in this case. GOO improved after stenting and recovery of oral intake was permanent after stent removal.

  4. Endovascular rescue method for undesirably stretched coil.

    Science.gov (United States)

    Cho, Jae Hoon

    2014-10-01

    Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter.

  5. Zwitterionic Nanofibers of Super-Glue for Transparent and Biocompatible Multi-Purpose Coatings

    Science.gov (United States)

    Mele, Elisa; Heredia-Guerrero, José A.; Bayer, Ilker S.; Ciofani, Gianni; Genchi, Giada G.; Ceseracciu, Luca; Davis, Alexander; Papadopoulou, Evie L.; Barthel, Markus J.; Marini, Lara; Ruffilli, Roberta; Athanassiou, Athanassia

    2015-09-01

    Here we show that macrozwitterions of poly(ethyl 2-cyanoacrylate), commonly called Super Glue, can easily assemble into long and well defined fibers by electrospinning. The resulting fibrous networks are thermally treated on glass in order to create transparent coatings whose superficial morphology recalls the organization of the initial electrospun mats. These textured coatings are characterized by low liquid adhesion and anti-staining performance. Furthermore, the low friction coefficient and excellent scratch resistance make them attractive as solid lubricants. The inherent texture of the coatings positively affects their biocompatibility. In fact, they are able to promote the proliferation and differentiation of myoblast stem cells. Optically-transparent and biocompatible coatings that simultaneously possess characteristics of low water contact angle hysteresis, low friction and mechanical robustness can find application in a wide range of technological sectors, from the construction and automotive industries to electronic and biomedical devices.

  6. Transarterial Embolization of Anomalous Systemic Arterial Supply to Normal Basal Segments of the Lung

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Sen, E-mail: jasfly77@vip.163.com; Yu, Dong; Jie, Bing [Tongji University School of Medicine, Department of Radiology, Shanghai Pulmonary Hospital (China)

    2016-09-15

    PurposeTo evaluate transarterial embolization (TAE) for the management of anomalous systemic arterial (ASA) supply to normal basal segments of the lung.MethodsThirteen patients with ASA supply to normal basal segments of the lung underwent TAE. All patients presented with hemoptysis and had complete-type anomalies on pre-TAE or post-TAE computed tomography (CT). The anomaly was unilateral in all patients; 11 lesions were located in the left lung and 2 in the right. All patients underwent embolization with coils (n = 10) or a vascular plug (n = 3). Procedural success, clinical efficacy, and complications were assessed. Mean post-TAE CT and clinical follow-up was 25.4 and 42.1 months, respectively.ResultsTechnical success was achieved in 100 % of cases. Several changes were noted on follow-up CT: complete obstruction of the ASA in all cases, normal (n = 11) or decreased (n = 2) density of the affected lung parenchyma, reduction of the primary enlarged inferior pulmonary vein in all cases, and pulmonary infarction and thickening of the corresponding bronchial artery (n = 4). The main complication was pulmonary infarction in four cases.ConclusionTAE is a safe, effective, and minimally invasive therapeutic option for patients with ASA supply to normal basal segments of the lung.

  7. Ultrafine needle CO2 splenoportography: A comparative investigation with transarterial portography and MR portography

    International Nuclear Information System (INIS)

    Teng Gaojun; Deng Gang; Liu Zhensheng; Fang Wen; Zhu Guangyu; Li Guozhao; Guo Jinhe; He Shicheng; Dong Yonghua

    2006-01-01

    Purpose: To evaluate the safety and quality of CO 2 splenoportography (CO 2 -SP) by comparison to 3-dimensional dynamic contrast-enhanced magnetic resonance portography (3D-DCE-MRP) and transarterial portography (TAP). Materials and methods: CO 2 -SP, 3D-DCE-MRP and TAP were performed within 3 days in 35 patients. CO 2 -SP was conducted with a 26 G needle by puncture of spleen under fluoroscopy and/or ultrasound guidance. A fifty mm 3 of CO 2 was manually injected within 3 s. The safety and the side effects of CO 2 -SP were assessed with a scoring system based on both the subjective feeling of patients questioned and the objective appearances of vital signs, electrocardiogram (ECG) and saturation of percutaneous blood oxygen (SpO 2 ). The quality of the imaging was compared among the three groups using different methods by a scoring criterion based on visualization of the portal branches. Results: Transient mild discomfortable reaction was present in 18 patients (51.4%). The scores measured for quality of portal vein branch visualization in the groups with CO 2 -SP, 3D-DCE-MRP and TAP were 226, 196 and 167, respectively (P 2 -SP is safe and minimally invasive. The quality of CO 2 -SP is better than that with 3D-DCE-MRP and TAP in terms of the visualizing portal vein branches

  8. Tolerance of glue embolization under local anesthesia in varicoceles: A comparative study of two different cyanoacrylates

    Energy Technology Data Exchange (ETDEWEB)

    Vanlangenhove, Peter, E-mail: peter.vanlangenhove@uzgent.be [Department of Vascular and Interventional Radiology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium); Everaert, Karel [Department of Urology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium); Van Maele, Georges [Department of Statistics, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium); Defreyne, Luc [Department of Vascular and Interventional Radiology, Ghent University Hospital, De Pintelaan 185, 9000 Ghent (Belgium)

    2014-03-15

    Purpose: To find out whether in varicocele embolization the copolymer cyanoacrylate glue (NBCA-MS) has a better patient tolerance compared to the monomer n-butyl-2-cyanoacrylate (NBCA). Materials and methods: N = 112 insufficient spermatic veins (left sided N = 84, right sided N = 28) diagnosed in N = 83 adult males were prospectively randomized for blinded embolization with either NBCA N = 54 (Histoacryl) or with NBCA-MS N = 58 (Glubran2). Before, during and up to one week after embolization, patient discomfort was assessed by a standardized pain scale. Type, location and side of discomfort were noted. Statistical analysis was performed with the Mann–Whitney U-test, the McNemar test and the Fisher's exact test. Results: Embolization caused discomfort in N = 48/112 (43%) spermatic veins, comprising N = 26/54 (48%) in the NBCA group and N = 22/58 (38%) in the NBCA-MS group. During the week after embolization, the overall number of discomfort reports rose to N = 62/106 (59%), with an increase to N = 30/53 (57%) in the NBCA group and to N = 32/53 (60%) in the NBCA-MS group. The number of immediate grade 2 to 4 pain reactions was N = 22/112 (20%), and rose to N = 37/106 (35%) after one week. No difference in discomfort during embolization and at 1 week after treatment was noted. Characteristics, severity grading, and location of discomfort were similar in both NBCA groups, regardless the time point of observation. Conclusion: Discomfort after glue embolization of varicocele is a common side effect, which might evolve to pain. The assumed lower inflammatory reaction on NBCA-MS was not translated in an improved tolerance.

  9. GlueX: The Search for Gluonic Excitations at Jefferson Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    D.S. Carman

    2005-08-21

    One of the unanswered and most fundamental questions in physics regards the nature of the confinement mechanism of quarks and gluons in quantum chromodynamics (QCD). Exotic hybrid mesons manifest gluonic degrees of freedom and their detailed spectroscopy will provide the precision data necessary to test assumptions in lattice QCD and the specific phenomenology leading to confinement. Photoproduction is expected to be a particularly effective manner to produce exotic hybrids, however, existing data using photon beams are sparse. At Jefferson Laboratory, plans are underway by the GlueX Collaboration to use the coherent bremsstrahlung technique to produce a linearly polarized photon beam. A solenoid-based hermetic detector will be used to collect data on meson production and decays with statistics that will exceed existing photoproduction data by several orders of magnitude after the first year of running. In order to reach the ideal photon energy of 9 GeV required for these studies, the energy of the Jefferson Laboratory electron accelerator, CEBAF, will be doubled from its current maximum energy of 6 GeV to 12 GeV. The physics motivating the search and the status of the project are reviewed.

  10. Transarterial chemoembolization versus resection for intermediate-stage (BCLC B hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Jun Young Kim

    2016-06-01

    Full Text Available Background/Aims: Several studies have suggested that surgical resection (SR can provide a survival benefit over transarterial chemoembolization (TACE for hepatocellular carcinoma (HCC at the intermediate stage according to the Barcelona Clinic Liver Cancer (BCLC staging system. However, the criteria for SR remain to be determined. This study compared the long-term outcome of intermediate-stage HCC patients treated by either TACE or SR as a primary treatment modality, with the aim of identifying the patient subgroup that gained a survival benefit by either modality. Methods: In total, 277 BCLC intermediate-stage HCC patients treated by either TACE (N=225 or SR (N=52 were analyzed. Results: The overall median survival time was significantly better for SR than TACE (61 vs. 30 months, P=0.002. Decision-tree analysis divided patients into seven nodes based on tumor size and number, serum alpha-fetoprotein (AFP level, and Child-Pugh score, and these were then simplified into four subgroups (B1–B4 based on similarities in the overall hazard rate. SR provided a significant survival benefit in subgroup B2, characterized by ‘oligo’ (2–4 nodules of intermediate size (5–10 cm when the AFP levels was <400 ng/ml, or ‘oligo’ (2–4 nodules of small to intermediate size (<10 cm plus a Child-Pugh score of 5 when the AFP level was ≥400 ng/mL (median survival 73 vs. 28 months for SR vs. TACE respectively; P=0.014. The survival rate did not differ significantly between SR and TACE in the other subgroups (B1 and B3. Conclusion: SR provided a survival benefit over TACE in intermediate-stage HCC, especially for patients meeting certain criteria. Re-establishing the criteria for optimal treatment modalities in this stage of HCC is needed to improve survival rates.

  11. Preliminary results of transarterial rhenium-188 HDD lipiodol in the treatment of inoperable primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Sundram, Felix; Chau, Tran Chi Minh; Onkhuudai, Peljee; Bernal, Patricia; Padhy, Ajit Kumar

    2004-01-01

    of the study, when the activities administered started at 1.8 GBq (50 mCi) and rose to 7.7 GBq (206 mCi). In the efficacy phase of the study a further 54 patients were treated. Both groups of patients are included in this paper. The treatment activity of 188 Re-lipiodol administered transarterially ranged from 1.8 to 9.8 GBq (50-265 mCi), with a mean activity of 4.6 GBq (124 mCi). Survival at 3 months was 90%, and at 6 months, 60%; 19% survived for 1 year. Mean survival after treatment in the total treated group of 70 patients was 9.5 months, with a range of 1-18 months. The results of the study show that 188 Re-lipiodol is a safe and cost-effective method to treat primary HCC via the transarterial route. (orig.)

  12. Repetitive transarterial chemoembolization (rTACE) of hepatocellular carcinoma: comparisons between an arterial port system and conventional angiographic technique

    International Nuclear Information System (INIS)

    Hidajat, Nico; Griesshaber, Volker; Hildebrandt, Bert; Hosten, Norbert; Schroeder, Ralf-Juergen; Felix, Roland

    2004-01-01

    Purpose: To compare the cost and radiation exposure of repetitive transarterial chemoembolization (rTACE) using percutaneously implantable port system with rTACE using conventional catheterization technique. Materials and methods: In five patients with unresectable hepatocellular carcinoma, three cycles of TACE were performed using conventional technique and six cycles using port. The cumulative cost of material and contrast agent and dose area product (DAP) were compared with the cost and DAP that would be expected if the rTACE was performed conventionally. Results: The cost of material and contrast agent was 1002.6 Euro after three cycles of TACE using conventional technique and six cycles using port, but would be 1111.8 Euro if the nine cycles were performed using conventional technique alone. The rTACE with three cycles using conventional technique and six cycles using port led to ∼63% of the cumulative DAP that would be expected in rTACE using conventional technique alone. Conclusion: In rTACE, the use of percutaneously implantable port system might enable a reduction of cost and radiation exposure

  13. Gas chromatography-mass spectrometry characterization of the varnish and glue of an ancient 18th century double bass.

    Science.gov (United States)

    Caruso, Francesco; Orecchio, Santino; Cicero, Maria Grazia; Di Stefano, Cosimo

    2007-04-20

    A GC-MS investigation is conducted on the double bass "Panormus", property of Conservatorio di Musica "Vincenzo Bellini" in Palermo. The most important components of the varnish (fatty acids) and of the glue (proteinaceous amino acids), with which the musical instrument was treated in the past, are determined. The analyses are carried out by prior derivatization of fatty acids by acidic methanol and of amino acids by acidic methanol and trifluoroacetic anhydride (TFAA). Analytes identification is achieved by direct comparison with several reference materials and the use of a digitized library.

  14. Staple Line Reinforcement During Laparoscopic Sleeve Gastrectomy: Absorbable Monofilament, Barbed Suture, Fibrin Glue, or Nothing? Results of a Prospective Randomized Study.

    Science.gov (United States)

    Carandina, S; Tabbara, M; Bossi, M; Valenti, A; Polliand, C; Genser, L; Barrat, Christophe

    2016-02-01

    Laparoscopic sleeve gastrectomy (LSG) is associated with serious complications, such as staple line (SL) leaks and bleeding. In order to prevent the occurrence of these complications, surgeons have advocated the need to strengthen the staple line. The aim of this randomized controlled study was to compare the efficacy of three different ways of strengthening of the SL in LSG in preventing surgical post-operative complications. Between April 2012 and December 2014, 600 patients (pts) scheduled for LSG were prospectively randomized into groups without SL reinforcement (group A) or with SL reinforcement including fibrin glue coverage (group B), or oversewn SL with imbricating absorbable (Monocryl™; group C) or barbed (V lock®) running suture (group D). Primary endpoints were post-operative leaks, bleeding, and stenosis, while secondary outcomes consisted of the time to perform the staple line reinforcement (SLR) and total operative time. Mean SLR operative time was lower for group B (3.4 ± 1.3 min) compared with that for groups C (26.8 ± 8.5 min) and D (21.1 ± 8.4 min) (p running suture or with fibrin glue, is an unrewarding surgical act with the sole effect of prolonging the operative time.

  15. Uncertainty assessment of integrated distributed hydrological models using GLUE with Markov chain Monte Carlo sampling

    DEFF Research Database (Denmark)

    Blasone, Roberta-Serena; Madsen, Henrik; Rosbjerg, Dan

    2008-01-01

    uncertainty estimation (GLUE) procedure based on Markov chain Monte Carlo sampling is applied in order to improve the performance of the methodology in estimating parameters and posterior output distributions. The description of the spatial variations of the hydrological processes is accounted for by defining......In recent years, there has been an increase in the application of distributed, physically-based and integrated hydrological models. Many questions regarding how to properly calibrate and validate distributed models and assess the uncertainty of the estimated parameters and the spatially......-site validation must complement the usual time validation. In this study, we develop, through an application, a comprehensive framework for multi-criteria calibration and uncertainty assessment of distributed physically-based, integrated hydrological models. A revised version of the generalized likelihood...

  16. Transarterial embolization in the management of intractable epistaxis: the angiographic findings and results based on etiologies.

    Science.gov (United States)

    Wang, Bin; Zu, Qing-Quan; Liu, Xing-Long; Zhou, Chun-Gao; Xia, Jin-Guo; Zhao, Lin-Bo; Shi, Hai-Bin; Liu, Sheng

    2016-08-01

    Transarterial embolization (TAE) appears to be a safe and effective treatment for patients with intractable epistaxis, despite different etiologies or angiography findings. Idiopathic epistaxis is prone to present with negative angiographic findings. To retrospectively evaluate the safety and effectiveness of TAE for intractable epistaxis, and focus on the factors of etiology and angiographic findings. From March 2008 to December 2014, the data of 43 patients with intractable bleeding undergoing TAE were reviewed. The outcomes of interventional therapy were assessed according to different etiology (malignant or benign disease) and angiographic finding (positive or negative angiogram). Positive angiographic findings were found in 11 of 12 cases with malignant diseases and 22 of 31 cases with benign diseases, respectively (p = 0.237). Among the 10 cases with negative angiographic findings, the negative angiography rate of idiopathic epistaxis was higher than that of epistaxis with definite etiology (p = 0.003). Bleeding was controlled successfully in all of the 43 patients after embolization. During the mean follow-up period of 24.0 ± 16.7 months, five patients relapsed. No significant difference was found in recurrence rates between malignant and benign diseases or between positive and negative angiography (p = 0.241, p = 0.704, respectively).

  17. Treatment for intractable anemia with the traditional Chinese medicines Hominis Placenta and Cervi Cornus Colla (deer antler glue

    Directory of Open Access Journals (Sweden)

    Yasuyo Hijikata

    2009-05-01

    Full Text Available Yasuyo Hijikata1, Takashi Kano2, Lu Xi31Toyodo Hijikata Clinic, Osaka, Japan; 2Kano Clinic, Osaka city, Osaka, Japan; 3Traditional Chinese Medicine Institute, Si-chuan Province, ChinaObjective: Intractable anemia, such as aplastic anemia or that presumably associated with chronic herpes virus infections, sometimes require bone marrow transplant. We investigated the use of traditional Chinese medicine (TCM for the treatment of intractable anemia. Method: Placenta Hominis (PH, steam boiled and roasted, and Cervi Cornus Colla (deer antler glue has been used in China for hundreds of years to treat anemia. After consent was obtained, we prescribed these two materials for a 74-year-old female with aplastic anemia and a 26-year-old male with presumably a virus-induced anemia. Concomitant conventional therapy was continued in both patients as prescribed by their respective attending physicians. Conclusion: Conventional therapy with steroid hormones, immunosuppressive drugs, platelet and erythrocyte transfusions were not effective in these patients. In addition, both patients suffered from serious side effects. In two patients, ingestion of Placenta Hominis and Cervi Cornus Colla with TCM prescriptions increased the platelet and enhanced the hemoglobin concentration in several months of therapy accompanied by a dramatic improvement in quality of life. The addition to conventional therapy of PH and Cervi Cornus Colla, the latter of which is very easy to obtain, may be one of the potentially advantageous choices in case of otherwise intractable anemia.Keywords: placenta, antler glue, Cervi Cornus Colla, anemia, aplastic anemia

  18. Monorail snare technique for the recovery of stretched platinum coils: technical case report.

    Science.gov (United States)

    Fiorella, David; Albuquerque, Felipe C; Deshmukh, Vivek R; McDougall, Cameron G

    2005-07-01

    Coil stretching represents a potentially hazardous technical complication not infrequently encountered during the embolization of cerebral aneurysms. Often, the stretched coil cannot be advanced into the aneurysm or withdrawn intact. The operator is then forced to attempt to retract the damaged coil, which may result in coil breakage, leaving behind a significant length of potentially thrombogenic stretched coil material within the parent vessel. To overcome this problem, we devised a technique to snare the distal, unstretched, intact portion of the platinum coil by use of the indwelling microcatheter and stretched portion of the coil as a monorail guide. We have used this technique successfully in four patients to snare coils stretched during cerebral aneurysm embolization. Three of these patients were undergoing Neuroform (Boston Scientific/Target, Fremont, CA) stent-supported coil embolization of unruptured aneurysms. In all cases, the snare was advanced easily to the targeted site for coil engagement by use of the microcatheter as a monorail guide. Once the intact distal segment of the coil was ensnared, coil removal was uneventful, with no disturbance of the remainder of the indwelling coil pack or Neuroform stent. A 2-mm Amplatz Goose Neck microsnare (Microvena Corp., White Bear Lake, MN) was placed through a Prowler-14 microcatheter (Cordis Corp., Miami, FL). The hub of the indwelling SL-10 microcatheter (Boston Scientific, Natick, MA) was then cut away with a scalpel, leaving the coil pusher wire intact, and removed. The open 2-mm snare was then advanced over the outside of the coil pusher wire and microcatheter. The snare and Prowler-14 microcatheter were then advanced into the guiding catheter (6- or 7-French) as a unit over the indwelling SL-10 microcatheter. By use of the SL-10 microcatheter and coil as a "monorail" guide, the snare was advanced over and beyond the microcatheter and the stretched portion of the coil until the snare was in position to

  19. First e⁻/γ Commissioning Results for the GlueX Experiment/Hall D at CEBAF

    Energy Technology Data Exchange (ETDEWEB)

    McCaughan, Michael D. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Satogata, Todd J. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Roblin, Yves R. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Benesch, Jay F. [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2015-09-01

    Experimental Hall D, with flagship experiment GlueX, was constructed as part of the 12 GeV CEBAF upgrade. A new magnetically extracted electron beam line was installed to support this hall. Bremsstrahlung photons from retractable radiators are delivered to the experiment through a series of collimators following a long drift to allow for beam convergence. Coherent Bremsstrahlung generated by interaction with a diamond radiator will achieve a nominal 40% linear polarization and photon energies between 8.5 and 9 GeV from 12.1 GeV electrons, which are then tagged or diverted to a medium power 60kW electron dump. The expected photon flux is 107-108 Hz. This paper discusses the experimental line design, commissioning experience gained since first beam in spring 2014, and the present results of beam commissioning by the experiment.

  20. Transarterial chemoembolization of hepatocellular carcinoma in a rat model: the effect of additional injection of survivin siRNA to the treatment protocol

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Oppermann, Elsie; Qian, Jun; Imlau, Ulli; Tran, Andreas; Hamidavi, Yousef; Korkusuz, Huedayi; Bechstein, Wolf Otto; Nour-Eldin, Nour-Eldin Abdel-Rehim; Gruber-Rouh, Tatjana; Hammerstingl, Renate; Naguib, Nagy Naguib Naeem

    2016-01-01

    Transarterial chemoembolization is one of the most widely accepted interventional treatment options for treatment of hepatocellular carcinoma. Still there is a lack of a standard protocol regarding the injected chemotherapeutics. Survivin is an inhibitor of Apoptosis protein that functions to inhibit apoptosis, promote proliferation, and enhance invasion. Survivin is selectively up-regulated in many human tumors. Small interfering RNA (siRNA) can trigger an RNA interference response in mammalian cells and induce strong inhibition of specific gene expression including Survivin. The aim of the study is to assess the effectiveness of the additional injection of Survivin siRNA to the routine protocol of Transarterial Chemoembolization (TACE) for the treatment of hepatocellular carcinoma in a rat model. The study was performed on 20 male ACI rats. On day 0 a solid Morris Hepatoma 3924A was subcapsullary implanted in the liver. On day 12 MRI measurement of the initial tumor volume (V1) was performed. TACE was performed on day 13. The rats were divided into 2 groups; Group (A, n = 10) in which 0.1 mg mitomycin, 0.1 ml lipiodol and 5.0 mg degradable starch microspheres were injected in addition 2.5 nmol survivin siRNA were injected. The same agents were injected in Group (B,=10) without Survivin siRNA. MRI was repeated on day 25 to assess the tumor volume (V2). The tumor growth ratio (V2/V1) was calculated. Western blot and immunohistochemical analysis were performed. For group A the mean tumor growth ratio (V2/V1) was 1.1313 +/− 0.1381, and was 3.1911 +/− 0.1393 in group B. A statistically significant difference between both groups was observed regarding the inhibition of tumor growth (P < 0.0001) where Group A showed more inhibition compared to Group B. Similarly immunohistochemical analysis showed significantly lower (p < 0.002) VEGF staining in group A compared to group B. Western Blot analysis showed a similar difference in VEGF expression (P < 0.0001). The

  1. Informal uncertainty analysis (GLUE) of continuous flow simulation in a hybrid sewer system with infiltration inflow - Consistency of containment ratios in calibration and validation?

    DEFF Research Database (Denmark)

    Breinholt, Anders; Grum, Morten; Madsen, Henrik

    2013-01-01

    to assess parameter and flow simulation uncertainty using a simplified lumped sewer model that accounts for three separate flow contributions: wastewater, fast runoff from paved areas, and slow infiltrating water from permeable areas. Recently GLUE methodology has been critisised for generating prediction...... rain inputs and more accurate flow observations to reduce parameter and model simulation uncertainty. © Author(s) 2013....

  2. Preliminary results of transarterial rhenium-188 HDD lipiodol in the treatment of inoperable primary hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sundram, Felix [Nuclear Medicine Department (The PET Centre), Singapore General Hospital, Block 2 Basement 1, Outram Road, 169608 (Singapore); Chau, Tran Chi Minh [Nuclear Medicine Department, Cho Ray Hospital, Ho Chi Minh City (Viet Nam); Onkhuudai, Peljee [Nuclear Medicine Department, First Central University Hospital, Ulaanbatax (Mongolia); Bernal, Patricia [Nuclear Medicine Department, Fundacion Santa Fe, Bogota (Colombia); Padhy, Ajit Kumar [Division of Human Health, International Atomic Energy Agency, Vienna (Austria)

    2004-02-01

    treated in the dose escalation phase of the study, when the activities administered started at 1.8 GBq (50 mCi) and rose to 7.7 GBq (206 mCi). In the efficacy phase of the study a further 54 patients were treated. Both groups of patients are included in this paper. The treatment activity of {sup 188}Re-lipiodol administered transarterially ranged from 1.8 to 9.8 GBq (50-265 mCi), with a mean activity of 4.6 GBq (124 mCi). Survival at 3 months was 90%, and at 6 months, 60%; 19% survived for 1 year. Mean survival after treatment in the total treated group of 70 patients was 9.5 months, with a range of 1-18 months. The results of the study show that {sup 188}Re-lipiodol is a safe and cost-effective method to treat primary HCC via the transarterial route. (orig.)

  3. Glue Ear, Hearing Loss and IQ: An Association Moderated by the Child’s Home Environment

    Science.gov (United States)

    Hall, Amanda J.; Maw, Richard; Midgley, Elizabeth; Golding, Jean; Steer, Colin

    2014-01-01

    Background Glue ear or otitis media with effusion (OME) is common in children and may be associated with hearing loss (HL). For most children it has no long lasting effects on cognitive development but it is unclear whether there are subgroups at higher risk of sequelae. Objectives To examine the association between a score comprising the number of times a child had OME and HL (OME/HL score) in the first four/five years of life and IQ at age 4 and 8. To examine whether any association between OME/HL and IQ is moderated by socioeconomic, child or family factors. Methods Prospective, longitudinal cohort study: the Avon Longitudinal Study of Parents and Children (ALSPAC). 1155 children tested using tympanometry on up to nine occasions and hearing for speech (word recognition) on up to three occasions between age 8 months and 5 years. An OME/HL score was created and associations with IQ at ages 4 and 8 were examined. Potential moderators included a measure of the child’s cognitive stimulation at home (HOME score). Results For the whole sample at age 4 the group with the highest 10% OME/HL scores had performance IQ 5 points lower [95% CI −9, −1] and verbal IQ 6 points lower [95% CI −10, −3] than the unaffected group. By age 8 the evidence for group differences was weak. There were significant interactions between OME/HL and the HOME score: those with high OME/HL scores and low 18 month HOME scores had lower IQ at age 4 and 8 than those with high OME/HL scores and high HOME scores. Adjusted mean differences ranged from 5 to 8 IQ points at age 4 and 8. Conclusions The cognitive development of children from homes with lower levels of cognitive stimulation is susceptible to the effects of glue ear and hearing loss. PMID:24498289

  4. Hepatocellular carcinoma treated with transarterial chemoembolization: Evaluation with parametric contrast-enhanced ultrasonography

    Science.gov (United States)

    Moschouris, Hippocrates; Malagari, Katerina; Marinis, Athanasios; Kornezos, Ioannis; Stamatiou, Konstantinos; Nikas, Georgios; Papadaki, Marina Georgiou; Gkoutzios, Panagiotis

    2012-01-01

    AIM: To evaluate the response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE) using a simplified protocol of parametric contrast-enhanced ultrasound (pCEUS). METHODS: Eighteen patients with HCC (18 target tumors, diameter: 2.8-12 cm) were evaluated before, and 20 d after TACE. The distribution and morphology of TACE-induced necrosis in these tumors precluded accurate evaluation by visual assessment or by simple measurements. For pCEUS, a 4.8 mL bolus of SonoVue (Bracco, Milan, Italy) was intravenously administered and analysis of tumor perfusion during the initial phase of enhancement (0-30 s post injection) was performed with dedicated software (Qontrast, Bracco, Milan, Italy). Time-intensity curves were plotted and three parameters were calculated: peak intensity (PI, in percentage %), time to peak (TTP in seconds, s) and area under the curve during wash-in (AUC-WI, in arbitrary units, a.u). Magnetic resonance imaging was the standard imaging modality for post-treatment evaluation. Changes in tumor size were recorded and response was assessed according to response evaluation criteria in solid tumors criteria. RESULTS: A statistically significant decrease in PI and AUC-WI was observed in the treated tumors post TACE; PIpre: 21.5% ± 8.7% (mean ± SD), PIpost: 12.7% ± 6.7%, P < 0.001, AUC-WI pre: 17493 ± 9563 a.u, AUC-WI post: 9585 ± 5494 a.u, P < 0.001. A slight increase in TTP was noted post TACE, but this was not statistically significant; TTP pre: 13.1 ± 4.3 s, TTP post: 13.6 ± 4.2 s , P = 0.058). The changes in the aforementioned parameters were not accompanied by significant tumor shrinkage. CONCLUSION: pCEUS, even when limited to the study of the arterial phase of tumoral enhancement, can detect and quantify early perfusional changes in HCC post TACE. PMID:22937217

  5. Transarterial embolotherapy in patients with duodenal hemorrhage using microcoils and gelfoam particles

    International Nuclear Information System (INIS)

    Shin, Tae Beom; Kim, Young Hwan; Seong, Chang Kyu

    2004-01-01

    To assess the efficacy and safety of arterial embolotherapy in patients with massive duodenal hemorrhage. Between January 1999 and June 2002, 25 patients (age: 34-81, mean 58, male: 19, female: 6) underwent arterial embolization for duodenal hemorrhage after failed endoscopic therapy. The hemorrhage originated from duodenal ulcer in sixteen patients, from cancer with duodenal invasion in five patients, from endoscopic sphincterectomy in two patients, and from pseudoaneurysm complicating acute pancreatitis in two patients. Hemorrhage was detected at endoscopy and an attempt was made to treat it endoscopically in all patients, but failed in each case. At angiography, direct bleeding signs such as contrast extravasation or pseudoaneurysm were demonstrated in nineteen patients. In the six patients without angiographic evidence of bleeding, blind embolization of the gastroduodenal artery was performed based on the endoscopic examination. Microcoil and gelfoam particles were used as embolic agents. Hemostasis was achieved immediately after embolotherapy in 21 patients (84%). Bleeding recurred in 4 patients (16%), and of these cases, one was successfully treated purely by endoscopic means, a second was reembolized three times due to bleeding from the collateral vessels of the tumor and the two others were treated by surgery. After the procedure, six patients died (24%). The causes of death were disseminated intravascular coagulopathy, multiorgan failure, sepsis and acute renal failure. The underlying diseases of the deceased patients were cancers with duodenal invasion (n=4) and abdominal aortic aneurysm with ischemic colitis (n=1). Transarterial embolotherapy in the case of massive duodenal hemorrhage is a safe and effective procedure. Even in the absence of angiographic evidence of bleeding, blind embolization of the gastroduodenal artery is effective for patients in the surgically high risk group

  6. Usefulness of intra-arterial embolization method using gelfoam particles in effective gene transduction of adenoviral vector for liver-directed gene therapy: an preliminary animal study in dogs

    International Nuclear Information System (INIS)

    Lee, Jin Hwa; Park, Byeong Ho; Kim, Chan Sung

    2003-01-01

    Liver-directed gene therapy is being actively pursued and developed as a method of treating various liver diseases. A number of aspects, including gene intervention, an efficient gene delivery system, and stable transgene expression are key to the success of the chosen strategy, and to overcome problems in these areas, several tactics can be used. In this study, we assess the utility of transarterial embolization using gelfoam particles soaked in an adenovirus vector as a gene-delivery method. Using the angiographic approach, three dogs each weighing 9.5-11kg were superselectively catheterized at the left hepatic artery using a 3-F microcatheter and the coaxial method. Two of the dogs were embolized at the left hepatic artery using 3x2x2-mm and 2x1x1-mm gelfoam particles soaked in 2x10 11 particles/kg of recombinant adv. CMV.LacZ(LacZ-adv). The left hepatic artery of the remaining animal, used as a control, was infused with the same dose of lacZ-adv in the same way as before but without embolization of the left hepatic artery. Three days after embolization or the infusion of LacZ-adv, the dogs were sacrificed prior to harvest of the entire liver for the evaluation of gene transduction. X-gal staining of the liver tissue obtained was positive for hepatocytes, but the pattern and degree of gene transduction differed according to gelfoam particle size. Where this was 3x2x2 mm, gene transduction along the liver hilum varied, but where 2x1x1-mm particles were used, transduction was more even. No pathologic hepatic tissue injury or inflammation was apparent, and control liver tissue was not stained by X-gal. Serum SGOT and SGPT levels were slightly higher one day after the procedure, but had normalized by day 3. Intrahepatic transarterial embolization using gelfoam particles soaked in LacZ-adv appears to be a good method for effective liver-targed gene therapy

  7. Usefulness of intra-arterial embolization method using gelfoam particles in effective gene transduction of adenoviral vector for liver-directed gene therapy: an preliminary animal study in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hwa; Park, Byeong Ho; Kim, Chan Sung [Dong-A University College of Medicine, Pusan (Korea, Republic of)

    2003-02-01

    Liver-directed gene therapy is being actively pursued and developed as a method of treating various liver diseases. A number of aspects, including gene intervention, an efficient gene delivery system, and stable transgene expression are key to the success of the chosen strategy, and to overcome problems in these areas, several tactics can be used. In this study, we assess the utility of transarterial embolization using gelfoam particles soaked in an adenovirus vector as a gene-delivery method. Using the angiographic approach, three dogs each weighing 9.5-11kg were superselectively catheterized at the left hepatic artery using a 3-F microcatheter and the coaxial method. Two of the dogs were embolized at the left hepatic artery using 3x2x2-mm and 2x1x1-mm gelfoam particles soaked in 2x10{sup 11} particles/kg of recombinant adv. CMV.LacZ(LacZ-adv). The left hepatic artery of the remaining animal, used as a control, was infused with the same dose of lacZ-adv in the same way as before but without embolization of the left hepatic artery. Three days after embolization or the infusion of LacZ-adv, the dogs were sacrificed prior to harvest of the entire liver for the evaluation of gene transduction. X-gal staining of the liver tissue obtained was positive for hepatocytes, but the pattern and degree of gene transduction differed according to gelfoam particle size. Where this was 3x2x2 mm, gene transduction along the liver hilum varied, but where 2x1x1-mm particles were used, transduction was more even. No pathologic hepatic tissue injury or inflammation was apparent, and control liver tissue was not stained by X-gal. Serum SGOT and SGPT levels were slightly higher one day after the procedure, but had normalized by day 3. Intrahepatic transarterial embolization using gelfoam particles soaked in LacZ-adv appears to be a good method for effective liver-targed gene therapy.

  8. A new platelet cryoprecipitate glue promoting bone formation after ectopic mesenchymal stromal cell-loaded biomaterial implantation in nude mice.

    Science.gov (United States)

    Trouillas, Marina; Prat, Marie; Doucet, Christelle; Ernou, Isabelle; Laplace-Builhé, Corinne; Blancard, Patrick Saint; Holy, Xavier; Lataillade, Jean-Jacques

    2013-01-04

    This study investigated the promising effect of a new Platelet Glue obtained from Cryoprecipitation of Apheresis Platelet products (PGCAP) used in combination with Mesenchymal Stromal Cells (MSC) loaded on ceramic biomaterials to provide novel strategies enhancing bone repair. PGCAP growth factor content was analyzed by ELISA and compared to other platelet and plasma-derived products. MSC loaded on biomaterials (65% hydroxyapatite/35% beta-TCP or 100% beta-TCP) were embedded in PGCAP and grown in presence or not of osteogenic induction medium for 21 days. Biomaterials were then implanted subcutaneously in immunodeficient mice for 28 days. Effect of PGCAP on MSC was evaluated in vitro by proliferation and osteoblastic gene expression analysis and in vivo by histology and immunohistochemistry. We showed that PGCAP, compared to other platelet-derived products, allowed concentrating large amount of growth factors and cytokines which promoted MSC and osteoprogenitor proliferation. Next, we found that PGCAP improves the proliferation of MSC and osteogenic-induced MSC. Furthermore, we demonstrated that PGCAP up-regulates the mRNA expression of osteogenic markers (Collagen type I, Osteonectin, Osteopontin and Runx2). In vivo, type I collagen expressed in ectopic bone-like tissue was highly enhanced in biomaterials embedded in PGCAP in the absence of osteogenic pre-induction. Better results were obtained with 65% hydroxyapatite/35% beta-TCP biomaterials as compared to 100% beta-TCP. We have demonstrated that PGCAP is able to enhance in vitro MSC proliferation, osteoblastic differentiation and in vivo bone formation in the absence of osteogenic pre-induction. This clinically adaptable platelet glue could be of interest for improving bone repair.

  9. Design and Fabrication of Calibration Device for Scintillating Fibers of Tagger Microscope: For use in GlueX's QCD Experiment

    Science.gov (United States)

    Briere, Emily

    2012-10-01

    For decades, scientists have struggled to understand the chromo-electromagnetic field which confines quarks and gluons within the hadron. GlueX is a QCD experiment centered at Jefferson Lab, Virginia, seeking to better understand this gluonic field by exciting it and mapping the spectrum of exotic hybrid mesons that it generates. The experiment uses coherent bremsstrahlung radiation to produce a beam of photons, which due to their polarity act as virtual vector mesons. When incident on a liquid hydrogen target, these mesons are expected to form exotic hybrid mesons. Such particles quickly decay into new particles which are captured in a solenoid detector. The decays can then be reconstructed to examine the properties of the original exotic hybrid meson, although the initial energy of the photon is required to draw meaningful conclusions. The post-bremsstrahlung degraded electrons are bent from the main beam into the tagger microscope where they strike an array of scintillating optical fibers. Given the correlation between momentum and radial bend, the Silicon Photmultiplier sensors attached to the optical fibers are able to ``tag'' the electrons', and thus the photons', initial energies based on which fibers were hit. Providing central data for GlueX, the tagger microscope must be accurate. This paper details the design and fabrication of a scintillating fiber calibration device that moves horizontally above fiber bundles, using a green laser diode to direct light pulses into the fibers. This calibration method has been tested mechanically and via a Monte Carlo Matlab simulation, and has proven to be effective.

  10. A New Potential Cause in the Development of Toxic Anterior Segment Syndrome: Fibrin Glue

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2014-08-01

    Full Text Available Objectives: To present a potential cause for toxic anterior segment syndrome (TASS. Materials and Methods: We report 4 cases of TASS that occurred following uneventful phacoemulsification and intraocular lens implantation. Results: The 4 cases were the first consecutive 2 cases of 2 different surgery days, 5 months apart. The most prominent sign of TASS was limbus-to-limbus corneal edema. Pain and/or intraocular pressure rise were also common. All surgical and presurgical procedures were checked after the first outbreak, whereas the second outbreak required further investigation. Fibrin glue remnants from preceding pterygium surgery with conjunctival autografting were found to be the potential cause. Despite intensive corticosteroid therapy, corneal edema did not resolve in 2 patients who underwent keratoplasty. Conclusion: TASS is a sight-threatening condition which requires thorough investigation for prevention of new cases. All steps must be carefully revised. (Turk J Ophthalmol 2014; 44: 280-3

  11. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation.

    Science.gov (United States)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Manhart, Michael; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman

    2018-01-01

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared RESULTS: Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (pprototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. • Metal objects cause artefacts in cone-beam computed tomography (CBCT) imaging. • These artefacts can be corrected by metal artefact reduction (MAR) algorithms. • Corrected images show significantly better visibility of nearby hepatic vessels and tissue. • Better visibility may facilitate image interpretation, save time and radiation exposure.

  12. Molecular glues for manipulating enzymes: trypsin inhibition by benzamidine-conjugated molecular glues† †Electronic supplementary information (ESI) available: Synthesis of TEG–BA, Gluen–BA, mGluen–BA and Gluen–Ph; 1H NMR, 13C NMR, MALDI-TOF MS, electronic absorption, and CD spectra; zeta potential distributions; SLS plots; DLS histograms; and related experimental procedures. See DOI: 10.1039/c5sc00524h Click here for additional data file.

    Science.gov (United States)

    Mogaki, Rina

    2015-01-01

    Water-soluble bioadhesive polymers bearing multiple guanidinium ion (Gu+) pendants at their side-chain termini (Gluen–BA, n = 10 and 29) that were conjugated with benzamidine (BA) as a trypsin inhibitor were developed. The Gluen–BA molecules are supposed to adhere to oxyanionic regions of the trypsin surface, even in buffer, via a multivalent Gu+/oxyanion salt-bridge interaction, such that their BA group properly blocks the substrate-binding site. In fact, Glue10–BA and Glue29–BA exhibited 35- and 200-fold higher affinities for trypsin, respectively, than a BA derivative without the glue moiety (TEG–BA). Most importantly, Glue10–BA inhibited the protease activity of trypsin 13-fold more than TEG–BA. In sharp contrast, mGlue27–BA, which bears 27 Gu+ units along the main chain and has a 5-fold higher affinity than TEG–BA for trypsin, was inferior even to TEG–BA for trypsin inhibition. PMID:28706668

  13. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    Energy Technology Data Exchange (ETDEWEB)

    Lv Mingming, E-mail: lvmingming001@163.com; Fan, Xin-dong, E-mail: fanxindong@yahoo.com.cn [Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ninth People' s Hospital (China); Su Lixin, E-mail: sulixin1975@126.com [Shanghai Jiao Tong University School of Medicine, Department of Oral and Maxillofacial Surgery, Ninth People' s Hospital (China); Chen Dong, E-mail: chenjsun@public8.sta.net.cn [Shanghai Jiao Tong University School of Medicine, Department of Otolaryngology, Ninth People' s Hospital (China)

    2013-02-15

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

  14. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    International Nuclear Information System (INIS)

    Lv Mingming; Fan, Xin-dong; Su Lixin; Chen Dong

    2013-01-01

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20–25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Control angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.

  15. CT-guided interstitial brachytherapy of hepatocellular carcinoma before liver transplantation: an equivalent alternative to transarterial chemoembolization?

    International Nuclear Information System (INIS)

    Denecke, Timm; Stelter, Lars; Schnapauff, Dirk; Steffen, Ingo; Gebauer, Bernhard; Lopez Haenninen, Enrique; Wust, Peter; Sinn, Bruno; Schott, Eckart; Seidensticker, Ricarda; Puhl, Gero; Neuhaus, Peter; Seehofer, Daniel

    2015-01-01

    Transarterial chemoembolization (TACE) is established as bridging therapy of HCC listed for transplantation (LT). CT-guided brachytherapy (CTB) has not been evaluated as a bridging concept. We compared CTB and TACE for bridging before LT in HCC patients. Twelve patients with HCC received LT after CTB (minimal tumour dose, 15-20 Gy). Patients were matched (CTB:TACE, 1:2) by sex, age, number and size of lesions, and underlying liver disease with patients who received TACE before transplantation. Study endpoints were extent of necrosis at histopathology and recurrence rate after OLT. There were no significant differences between the CTB and TACE groups regarding Child-Pugh category (p = 0.732), AFP (0.765), time on waiting list (p = 0.659), number (p = 0.698) and size (p = 0.853) of HCC lesions, fulfilment of Milan-criteria (p = 0.638), or previous liver-specific treatments. CTB achieved higher tumour necrosis rates than TACE (p = 0.018). The 1- and 3-year recurrence rate in the CTB group was 10 and 10 % vs. TACE, 14 and 30 % (p = 0.292). Our data show comparable or even better response and post-LT recurrence rates of CTB compared to TACE for treating HCC in patients prior to LT. CTB should be further evaluated as an alternative bridging modality, especially for patients not suited for TACE. (orig.)

  16. CT-guided interstitial brachytherapy of hepatocellular carcinoma before liver transplantation: an equivalent alternative to transarterial chemoembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Denecke, Timm; Stelter, Lars; Schnapauff, Dirk; Steffen, Ingo; Gebauer, Bernhard; Lopez Haenninen, Enrique; Wust, Peter [Universitaetsmedizin Berlin, Klinik fuer Radiologie, Charite, Berlin (Germany); Sinn, Bruno [Charite - Universitaetsmedizin Berlin, Institut fuer Pathologie, Berlin (Germany); Schott, Eckart [Charite 2 - Universitaetsmedizin Berlin, Medizinische Klinik m.S. Hepatologie und Gastroenterologie, Berlin (Germany); Seidensticker, Ricarda [Universitaetsklinikum der Otto-v.-Gericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Magdeburg (Germany); Puhl, Gero; Neuhaus, Peter; Seehofer, Daniel [Charite - Universitaetsmedizin Berlin, Klinik fuer Allgemein-, Viszeral- und Transplantationschirurgie, Berlin (Germany)

    2015-09-15

    Transarterial chemoembolization (TACE) is established as bridging therapy of HCC listed for transplantation (LT). CT-guided brachytherapy (CTB) has not been evaluated as a bridging concept. We compared CTB and TACE for bridging before LT in HCC patients. Twelve patients with HCC received LT after CTB (minimal tumour dose, 15-20 Gy). Patients were matched (CTB:TACE, 1:2) by sex, age, number and size of lesions, and underlying liver disease with patients who received TACE before transplantation. Study endpoints were extent of necrosis at histopathology and recurrence rate after OLT. There were no significant differences between the CTB and TACE groups regarding Child-Pugh category (p = 0.732), AFP (0.765), time on waiting list (p = 0.659), number (p = 0.698) and size (p = 0.853) of HCC lesions, fulfilment of Milan-criteria (p = 0.638), or previous liver-specific treatments. CTB achieved higher tumour necrosis rates than TACE (p = 0.018). The 1- and 3-year recurrence rate in the CTB group was 10 and 10 % vs. TACE, 14 and 30 % (p = 0.292). Our data show comparable or even better response and post-LT recurrence rates of CTB compared to TACE for treating HCC in patients prior to LT. CTB should be further evaluated as an alternative bridging modality, especially for patients not suited for TACE. (orig.)

  17. Management of uterine artery pseudoaneurysm: advanced ultrasonography imaging and laparoscopic surgery as an alternative method to angio-computed tomography and transarterial embolization.

    Science.gov (United States)

    Ciebiera, Michał; Słabuszewska-Jóźwiak, Aneta; Zaręba, Kornelia; Jakiel, Grzegorz

    2017-01-01

    Uterine artery pseudoaneurysms (UAP) are rare but potentially life-threatening lesions. They may occur after traumatic deliveries, cesarean sections, and other interventions. We present a case of a 39-year-old woman with a UAP. The patient was accurately diagnosed using ultrasound imaging, with subsequent diagnostic hysteroscopy and laparoscopic excision of the UAP. In the present case, a ligation of the artery branch was performed to provide accurate hemostasis during UAP dissection. The vascular lesion was partially enucleated and removed, followed by recreation of the previous uterine shape. Power Doppler with HD flow and 3D ultrasound are accurate methods in the diagnosis of UAP. We are of the opinion that laparoscopic surgery can be on a par with transarterial embolization. During laparoscopy, the surgeon can either close the feeding vessel or remove the pathological tissue. In our opinion, this method solves the problem permanently and, after a successful case series with long-term follow-up, might be applied in other centers as well.

  18. Quantum-dot-sensitized solar cells fabricated by the combined process of the direct attachment of colloidal CdSe quantum dots having a ZnS glue layer and spray pyrolysis deposition.

    Science.gov (United States)

    Im, Sang Hyuk; Lee, Yong Hui; Seok, Sang Il; Kim, Sung Woo; Kim, Sang-Wook

    2010-12-07

    We were able to attach CdSe quantum dots (QDs) having a ZnS inorganic glue layer directly to a mesoporous TiO(2) (mp-TiO(2)) surface by spray coating and thermal annealing. Quantum-dot-sensitized solar cells based on CdSe QDs having ZnS as the inorganic glue layer could easily transport generated charge carriers because of the intimate bonding between CdSe and mp-TiO(2). The application of spray pyrolysis deposition (SPD) to obtain additional CdSe layers improved the performance characteristics to V(oc) = 0.45 V, J(sc) = 10.7 mA/cm(2), fill factor = 35.8%, and power conversion efficiency = 1.7%. Furthermore, ZnS post-treatment improved the device performance to V(oc) = 0.57 V, J(sc) = 11.2 mA/cm(2), fill factor = 35.4%, and power conversion efficiency = 2.2%.

  19. Portal Vein Embolization Using a Nitinol Plug (Amplatzer Vascular Plug) in Combination with Histoacryl Glue and Iodinized Oil: Adequate Hypertrophy with a Reduced Risk of Nontarget Embolization

    International Nuclear Information System (INIS)

    Bent, Clare L.; Low, Deborah; Matson, Matthew B.; Renfrew, Ian; Fotheringham, Tim

    2009-01-01

    The purpose of this study was to assess whether portal vein embolization (PVE) using a nitinol vascular plug in combination with histoacryl glue and iodinized oil minimizes the risk of nontarget embolization while obtaining good levels of future liver remnant (FLR) hypertrophy. Between November 2005 and August 2008, 16 patients (8 females, 8 males; mean age, 63 ± 3.6 years), each with a small FLR, underwent right ipsilateral transhepatic PVE prior to major hepatectomy. Proximal PVE was initially performed by placement of a nitinol vascular plug, followed by distal embolization using a mixture of histoacryl glue and iodinized oil. Pre- and 6 weeks postprocedural FLR volumes were calculated using computed tomographic imaging. Selection for surgery required an FLR of 0.5% of the patient's body mass. Clinical course and outcome of surgical resection for all patients were recorded. At surgery, the ease of hepatectomy was subjectively assessed in comparison to previous experience following PVE with alternative embolic agents. PVE was successful in all patients. Mean procedure time was 30.4 ± 2.5 min. Mean absolute increase in FLR volume was 68.9% ± 12.0% (p = 0.00005). There was no evidence of nontarget embolization during the procedure or on subsequent imaging. Nine patients proceeded to extended hepatectomy. Six patients demonstrated disease progression. One patient did not achieve sufficient hypertrophy in relation to body mass to undergo hepatic resection. At surgery, the hepatobiliary surgeons observed less periportal inflammation compared to previous experience with alternative embolic agents, facilitating dissection at extended hepatectomy. In conclusion, ipsilateral transhepatic PVE using a single nitinol plug in combination with histoacryl glue and iodinized oil simplifies the procedure, offering short procedural times with minimal risk of nontarget embolization. Excellent levels of FLR hypertrophy are achieved enabling safe extended hepatectomy.

  20. Determining the hydraulic and fracture properties of the Coal Seam Gas well by numerical modelling and GLUE analysis

    Science.gov (United States)

    Askarimarnani, Sara; Willgoose, Garry; Fityus, Stephen

    2017-04-01

    Coal seam gas (CSG) is a form of natural gas that occurs in some coal seams. Coal seams have natural fractures with dual-porosity systems and low permeability. In the CSG industry, hydraulic fracturing is applied to increase the permeability and extract the gas more efficiently from the coal seam. The industry claims that it can design fracking patterns. Whether this is true or not, the public (and regulators) requires assurance that once a well has been fracked that the fracking has occurred according to plan and that the fracked well is safe. Thus defensible post-fracking testing methodologies for gas generating wells are required. In 2009 a fracked well HB02, owned by AGL, near Broke, NSW, Australia was subjected to "traditional" water pump-testing as part of this assurance process. Interpretation with well Type Curves and simple single phase (i.e. only water, no gas) highlighted deficiencies in traditional water well approaches with a systemic deviation from the qualitative characteristic of well drawdown curves (e.g. concavity versus convexity of drawdown with time). Accordingly a multiphase (i.e. water and methane) model of the well was developed and compared with the observed data. This paper will discuss the results of this multiphase testing using the TOUGH2 model and its EOS7C constitutive model. A key objective was to test a methodology, based on GLUE monte-carlo calibration technique, to calibrate the characteristics of the frack using the well test drawdown curve. GLUE involves a sensitivity analysis of how changes in the fracture properties change the well hydraulics through and analysis of the drawdown curve and changes in the cone of depression. This was undertaken by changing the native coal, fracture, and gas parameters to see how changing those parameters changed the match between simulations and the observed well drawdown. Results from the GLUE analysis show how much information is contained in the well drawdown curve for estimating field scale

  1. Fibrin glue as the cell-delivery vehicle for mesenchymal stromal cells in regenerative medicine.

    Science.gov (United States)

    Wu, Xiuwen; Ren, Jianan; Li, Jieshou

    2012-05-01

    The use of tissue-engineering techniques such as stem-cell therapy to renew injured tissues is a promising strategy in regenerative medicine. As a cell-delivery vehicle, fibrin glues (FG) facilitate cell attachment, growth and differentiation and, ultimately, tissue formation and organization by its three-dimensional structure. Numerous studies have provided evidence that stromal cells derived from bone marrow (bone marrow stromal cells; BMSC) and adipose tissue (adipose-derived stromal cells; ADSC) contain a population of adult multipotent mesenchymal stromal cells (MSC) and endothelial progenitor cells that can differentiate into several lineages. By combining MSC with FG, the implantation could take advantage of the mutual benefits. Researchers and physicians have pinned their hopes on stem cells for developing novel approaches in regenerative medicine. This review focuses on the therapeutic potential of MSC with FG in bone defect reconstruction, cartilage and tendon injury repair, ligament, heart and nerve regeneration, and, furthermore, wound healing.

  2. Experiences with the GLUE information schema in the LCG/EGEE production grid

    International Nuclear Information System (INIS)

    Burke, S; Andreozzi, S; Field, L

    2008-01-01

    A common information schema for the description of Grid resources and services is an essential requirement for interoperating Grid infrastructures, and its implementation interacts with every Grid component. In this context, the GLUE information schema was originally defined in 2002 as a joint project between the European DataGrid and DataTAG projects and the US iVDGL. The schema has major components to describe Computing and Storage Elements, and also generic Service and Site information. It has been used extensively in the LCG/EGEE Grid, for job submission, data management, service discovery and monitoring. In this paper we present the experience gained over the last five years, highlighting both successes and problems. In particular, we consider the importance of having a clear definition of schema attributes; the construction of standard information providers and difficulties encountered in mapping an abstract schema to diverse real systems; the configuration of publication in a way which suits system managers and the varying characteristics of Grid sites; the validation of published information; the ways in which information can be used (and misused) by Grid services and users; and issues related to managing schema upgrades in a large distributed system

  3. Stereotactic Body Radiation Therapy as an Alternative to Transarterial Chemoembolization for Hepatocellular Carcinoma.

    Science.gov (United States)

    Sapir, Eli; Tao, Yebin; Schipper, Matthew J; Bazzi, Latifa; Novelli, Paula M; Devlin, Pauline; Owen, Dawn; Cuneo, Kyle C; Lawrence, Theodore S; Parikh, Neehar D; Feng, Mary

    2018-01-01

    To conduct a large single-institution comparison of transarterial chemoembolization (TACE) and stereotactic body radiation therapy (SBRT) outcomes in similar groups of patients with hepatocellular carcinoma (HCC). From 2006 to 2014, 209 patients with 1 to 2 tumors underwent TACE (n=84) to 114 tumors or image guided SBRT (n=125) to 173 tumors. Propensity score analysis with inverse probability of treatment weighting was used to compare outcomes between treatments while adjusting for imbalances in treatment assignment. Local control (LC), toxicity, and overall survival (OS) were retrospectively analyzed. The TACE and SBRT groups were similar with respect to the number of tumors treated per patient, underlying liver disease, and baseline liver function. Patients treated with SBRT were older (65 vs 61 years, P=.01), had smaller tumors (2.3 vs 2.9 cm, P<.001), and less frequently underwent liver transplantation (8% vs 18%, P=.01). The 1- and 2-year LC favored SBRT: 97% and 91%, respectively, for SBRT and 47% and 23% for TACE (hazard ratio 66.5, P<.001). For patients treated with TACE, higher alpha-fetoprotein (hazard ratio 1.11 per doubling, P=.008) and segmental portal vein thrombosis (hazard ratio 9.9, P<.001) were associated with worse LC. Predictors associated with LC after SBRT were not identified. Grade 3+ toxicity occurred after 13% and 8% of TACE and SBRT treatments, respectively (P=.05). There was no difference in OS between patients treated with TACE or SBRT. Stereotactic body radiation therapy is a safe alternative to TACE for 1 to 2 tumors and provides better LC, with no observed difference in OS. Prospective comparative trials of TACE and SBRT are warranted. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Efficacy, Reliability, and Safety of Completely Autologous Fibrin Glue in Neurosurgical Procedures: Single-Center Retrospective Large-Number Case Study.

    Science.gov (United States)

    Nakayama, Noriyuki; Yano, Hirohito; Egashira, Yusuke; Enomoto, Yukiko; Ohe, Naoyuki; Kanemura, Nobuhiro; Kitagawa, Junichi; Iwama, Toru

    2018-01-01

    Commercially available fibrin glue (Com-FG), which is used commonly worldwide, is produced with pooled human plasma from multiple donors. However, it has added bovine aprotinin, which involves the risk of infection, allogenic immunity, and allergic reactions. We evaluate the efficacy, reliability, and safety of completely autologous fibrin glue (CAFG). From August 2014 to February 2016, prospective data were collected and analyzed from 153 patients. CAFG was prepared with the CryoSeal System using autologous blood and was applied during neurosurgical procedures. Using CAFG-soaked oxidized regenerated cellulose and/or polyglycolic acid sheets, we performed a pinpoint hemostasis, transposed the offending vessels in a microvascular decompression, and covered the dural incision to prevent cerebrospinal fluid leakage. The CryoSeal System had generated up to a mean of 4.51 mL (range, 3.0-8.4 mL) of CAFG from 400 mL autologous blood. Com-FG products were not used in our procedures. Only 6 patients required an additional allogeneic blood transfusion. The hemostatic effective rate was 96.1% (147 of 153 patients). Only 1 patient who received transsphenoidal surgery for a pituitary adenoma presented with the complication of delayed postoperative cerebrospinal fluid leakage (0.65%). No patient developed allergic reactions or systemic complications associated with the use of CAFG. CAFG effectively provides hemostatic, adhesive, and safety performance. The timing and three-dimensional shape of CAFG-soaked oxidized regenerated cellulose and/or polyglycolic acid sheets solidification can be controlled with slow fibrin formation. The cost to prepare CAFG is similar compared with Com-FG products, and it can therefore be easily used at most institutions. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Mechanism and Natural Course of Tumor Involution in Hepatocellular Carcinoma Following Transarterial Ethanol Ablation

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Simon Chun Ho, E-mail: simonyu@cuhk.edu.hk; Lau, Tiffany Wing Wa; Tang, Peggy; Chan, Stephen Ka Chi; Chu, Charmant Cheuk Man; Hui, Joyce Wai Yi [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince of Wales Hospital (Hong Kong); Lee, Kit Fai [Prince of Wales Hospital, Department of Surgery (Hong Kong); Chan, Anthony [The Chinese University of Hong Kong, Department of Anatomical and Cellular Pathology (Hong Kong)

    2016-08-15

    PurposeTo evaluate the microvascular distribution of lipiodol–ethanol, the histological change of the tumor lesion, and the status of tumor involution over time in hepatocellular carcinoma (HCC) following transarterial ethanol ablation (TEA), in lesions that showed CT evidence of complete tumor response.Materials and methodsPatients with unresectable HCC were treated (183 patients, 242 lesions) with TEA using lipiodol–ethanol mixture (LEM) mixed in 2:1 ratio by volume and followed with CT at 3-month intervals for a median of 14.1 months. Liver tumors (n = 131) that showed CT evidence of complete tumor response, defined as the absence of any enhancing tumor throughout the follow-up period, were included. The surgical specimens of five patients who subsequently received partial hepatectomy were available for histological assessment. The microvascular distribution of LEM and the degree of tumor necrosis were analyzed. Tumor involution over time was assessed with CT in lesions that showed complete response.ResultsLipid stain revealed lipiodol infiltration throughout arterioles, intratumoral sinusoidal spaces, tumor capsule, and peritumoral portal venules. Complete tumor necrosis (100 %) occurred in all 5 surgical specimens. The median (IQR) percentage tumor volume compared to baseline volumes at 12, 36, and 60 months was 32 % (23.5–52.5 %), 22 % (8–31 %), and 13.5 % (6–21.5 %), respectively.ConclusionIntrahepatic HCC lesion that showed CT evidence of complete tumor response following TEA is associated with histological evidence of LEM infiltration throughout the intratumoral and peritumoral vasculature and complete tumor necrosis, as well as sustained reduction in tumor volume over time.

  6. Hepatocellular carcinomas 2–3 cm in diameter: Transarterial chemoembolization plus radiofrequency ablation vs. radiofrequency ablation alone

    International Nuclear Information System (INIS)

    Kim, Jong Woo; Kim, Jin Hyoung; Won, Hyung Jin; Shin, Yong Moon; Yoon, Hyun-Ki; Sung, Kyu-Bo; Kim, Pyo Nyun

    2012-01-01

    Objective: There is debate whether transarterial chemoembolization (TACE) plus radiofrequency ablation (RFA) is more effective than RFA alone in the treatment of patients with small hepatocellular carcinoma (HCC). We therefore retrospectively compared these treatments in patients with HCCs of diameter 2–3 cm. Materials and methods: Outcomes, including tumor progression, survival rates, and major complications, were compared in 83 patients (83 tumors) treated with combined TACE and RFA and in 231 patients (231 tumors) treated with RFA alone. Results: Median follow-up periods were similar in the TACE + RFA and RFA alone groups (37 vs. 38 months). During follow-up, local tumor progression was observed in 16% and 41% of tumors, respectively. The 1, 3, and 5 year local tumor progression-free survival rates were significantly higher in the TACE + RFA group (95%, 86%, and 83%, respectively) than in the RFA-alone group (78%, 61%, and 53%, respectively; P < 0.001). The 1, 3, and 5 year overall survival rates, however, were similar in the TACE + RFA (93%, 72%, and 63%, respectively) and RFA (93%, 73%, and 53%, respectively) groups (P = 0.545), as were the rates of major complications (1.2% vs. 0.4%). Conclusions: Combined TACE and RFA was safe and provided better local tumor control than RFA alone in the treatment of 2- to 3-cm sized HCCs, although survival rates were similar.

  7. Effects of Oral L-Carnitine on Liver Functions after Transarterial Chemoembolization in Intermediate-Stage HCC Patients

    Directory of Open Access Journals (Sweden)

    Abeer Hassan

    2015-01-01

    Full Text Available Transarterial chemoembolization (TACE is usually followed by hepatic dysfunction. We evaluated the effects of L-carnitine on post-TACE impaired liver functions. Methods. 53 cirrhotic hepatocellular carcinoma patients at Osaka Medical College were enrolled in this study and assigned into either L-carnitine group receiving 600 mg oral L-carnitine daily or control group. Liver functions were evaluated at pre-TACE and 1, 4, and 12 weeks after TACE. Results. The L-carnitine group maintained Child-Pugh (CP score at 1 week after TACE and exhibited significant improvement at 4 weeks after TACE (P<0.01. Conversely, the control group reported a significant CP score deterioration at 1 week (P<0.05 and 12 weeks after TACE (P<0.05. L-carnitine suppressed serum albumin deterioration at 1 week after TACE. There were significant differences between L-carnitine and control groups regarding mean serum albumin changes from baseline to 1 week (P<0.05 and 4 weeks after TACE (P<0.05. L-carnitine caused prothrombin time improvement from baseline to 1, 4 (P<0.05, and 12 weeks after TACE. Total bilirubin mean changes from baseline to 1 week after TACE exhibited significant differences between L-carnitine and control groups (P<0.05. The hepatoprotective effects of L-carnitine were enhanced by branched chain amino acids combination. Conclusion. L-carnitine maintained and improved liver functions after TACE.

  8. Traditional Glue, Adhesive and Poison Used for Composite Weapons by Ju/'hoan San in Nyae Nyae, Namibia. Implications for the Evolution of Hunting Equipment in Prehistory.

    Science.gov (United States)

    Wadley, Lyn; Trower, Gary; Backwell, Lucinda; d'Errico, Francesco

    2015-01-01

    Ju/'hoan hunters from Nyae Nyae, near Tsumkwe in Namibia, demonstrate the manufacture of three fixative pastes made from plant extracts, and poison made from grubs and plant extracts. Ammocharis coranica and Terminalia sericea produce simple glue. Ozoroa schinzii latex mixed with carbonized Aristeda adscensionis grass is a compound adhesive. Composite poison is made from Chrysomelid grub viscera mixed with salivary extracts of Acacia mellifera inner bark and the tuber sap of Asparagus exuvialis. In order to document potential variability in the chaîne opératoire, and to eliminate inherent biases associated with unique observations, we studied manufacturing processes in three separate Nyae Nyae villages. Although there are methodological similarities in the Nyae Nyae area, we observed a few differences in contemporary traditions of poison manufacture. For example, some hunters make powder from Asparagus exuvialis tuber sap by boiling, reducing, hardening and grinding it, while others simply use heated sap. The Ju/'hoan hunting kit provides insights for archaeologists, but we must exercise caution when looking for continuity between prehistoric and historical technical systems. Some traditions have been lost to modern hunters, while others are new. We should also expect variability in the Stone Age because of geographically restricted resources. Simple glue, compound adhesive, and poison recipes identified in the Stone Age have no modern equivalents. By about 60,000 years ago at Diepkloof, simple glue was used for hafting tools, but at similarly-aged Sibudu there are recipes that combine red ochre powder with plant and/or animal ingredients. At Border Cave, novel poisons and compound adhesives were used in the Early Later Stone Age. It is possible that the complexity that we record in the manufacture of fixative pastes and poison used by Ju/'hoan hunters represents a hafting system both similar to and different from that observed at the Stone Age sites of Diepkloof

  9. Traditional Glue, Adhesive and Poison Used for Composite Weapons by Ju/'hoan San in Nyae Nyae, Namibia. Implications for the Evolution of Hunting Equipment in Prehistory.

    Directory of Open Access Journals (Sweden)

    Lyn Wadley

    Full Text Available Ju/'hoan hunters from Nyae Nyae, near Tsumkwe in Namibia, demonstrate the manufacture of three fixative pastes made from plant extracts, and poison made from grubs and plant extracts. Ammocharis coranica and Terminalia sericea produce simple glue. Ozoroa schinzii latex mixed with carbonized Aristeda adscensionis grass is a compound adhesive. Composite poison is made from Chrysomelid grub viscera mixed with salivary extracts of Acacia mellifera inner bark and the tuber sap of Asparagus exuvialis. In order to document potential variability in the chaîne opératoire, and to eliminate inherent biases associated with unique observations, we studied manufacturing processes in three separate Nyae Nyae villages. Although there are methodological similarities in the Nyae Nyae area, we observed a few differences in contemporary traditions of poison manufacture. For example, some hunters make powder from Asparagus exuvialis tuber sap by boiling, reducing, hardening and grinding it, while others simply use heated sap. The Ju/'hoan hunting kit provides insights for archaeologists, but we must exercise caution when looking for continuity between prehistoric and historical technical systems. Some traditions have been lost to modern hunters, while others are new. We should also expect variability in the Stone Age because of geographically restricted resources. Simple glue, compound adhesive, and poison recipes identified in the Stone Age have no modern equivalents. By about 60,000 years ago at Diepkloof, simple glue was used for hafting tools, but at similarly-aged Sibudu there are recipes that combine red ochre powder with plant and/or animal ingredients. At Border Cave, novel poisons and compound adhesives were used in the Early Later Stone Age. It is possible that the complexity that we record in the manufacture of fixative pastes and poison used by Ju/'hoan hunters represents a hafting system both similar to and different from that observed at the Stone

  10. The Features of Extrahepatic Collateral Arteries Related to Hepatic Artery Occlusion and Benefits in the Transarterial Management of Liver Tumors

    International Nuclear Information System (INIS)

    Yang, Lin; Zhang, Xiao Ming; Ren, Yong Jun; Miao, Nan Dong; Huang, Xiao Hua; Dong, Guo Li

    2013-01-01

    Purpose. To investigate the extrahepatic collateral arteries related to hepatic artery occlusion (HAO) and to determine its benefits in the transarterial management of liver tumors. Methods and Findings. Eleven patients (7 hepatocellular carcinomas, 3 liver metastases, and 1 with hemangioma) with HAO confirmed with digital subtraction angiography (DSA) were admitted to our hospital. Of the 11 patients, 7 were men and 4 were women, with an average age of 41.5 ± 15.5 years (range: 29 to 70 years). DSA was performed to evaluate the collateral routes to the liver. In the 11 patients with HAO, DSA showed complete occlusion of the common hepatic artery in 9 patients and the proper hepatic artery (PHA) in 2 patients. Extrahepatic collateral arteries supplying the liver were readily evident. The collateral arteries originated from the superior mesenteric artery (SMA) in 8 patients, from the gastroduodenal artery in 2 patients, and from the left gastric artery (LGA) in 1 patient. Transcatheter treatment was successfully performed via the collateral artery in all patients except the one who had hemangioma. Conclusions. DSA is an effective method for detecting collateral circulation related to HAO and may provide information to guide transcatheter management decisions

  11. 蛋白胶-罂粟碱复合体促进调Q Nd:YAG激光治疗后创面愈合的观察%Using Fibrin Glue Papaverine Complex to Promote Wounds Healing after Q-Switched Laser

    Institute of Scientific and Technical Information of China (English)

    朱玉; 李栋梁; 陈志勇; 谭强; 周业松

    2011-01-01

    目的 观察蛋白胶-罂粟碱复合体对调Q Nd:YAG激光治疗后创面愈合的促进作用.方法 太田痣患者50例,随机分为研究组和对照组,每组25例.以调Q Nd:YAG激光治疗后,分别应用蛋白胶-罂粟碱复合体或凡士林纱布覆盖创面,对比观察两组患者创面疼痛评分、止血时间及愈合时间.结果 研究组在创面疼痛评分、止血时间、创面愈合时间均优于对照组.结论 蛋白胶-罂粟碱复合体对调Q Nd:YAG激光治疗后的创面具有明显的减轻疼痛,促进愈合的作用.%Objective To observe the effects of using fibrin glue papaverine complex to promote wound healing after Q-switched laser therapy.Methods Fifty patients with nevus of Ota were randomly and equally assigned to two groupa: the study group applied fibrin glue papaverine complex and the control group applied vaseline gauze,and their wounds pain, hemostatic lime and healing time were compared.Results Covering wounds with glue papaverine complex after Q-switched laser was superior to the other therapy from aspects of pain alleviation, hemostatic time and healing time.Conclusions Covering wounds with glue papaverine complex after the treatment of Q-switched laser can alleviate the pain and accelerate the wound healing.

  12. Encephalopathy and Neuropathy due to Glue, Paint Thinner, and Gasoline Sniffing in Trinidad and Tobago-MRI Findings

    Directory of Open Access Journals (Sweden)

    Kanterpersad Ramcharan

    2014-01-01

    Full Text Available A 29-year-old male petrol station pump attendant was admitted with ataxia and clinical evidence of a sensorimotor polyneuropathy which developed over the preceding 3 months. He had cognitive dysfunction, hearing loss, and cerebellar clinical abnormalities that came on slowly over the three years. He had a fifteen-year history of sniffing mostly glue, occasionally paint thinners, and, in the recent two years, gasoline. Magnetic resonance brain imaging showed abnormalities of the cerebral cortex, cerebral white matter, corpus callosum, hippocampus, brainstem and cerebellar atrophy, hypointensities of basal ganglia, red nuclei, and substantia nigra as previously described in toluene sniffing. Abstinence for six months led to partial clinical improvement. Clinicians need to be aware of this preventable entity which has peculiar radiological findings which are being increasingly accepted as typical.

  13. Calibrations for charged particle tracking and measurements of w photoproduction with the GlueX detector

    Energy Technology Data Exchange (ETDEWEB)

    Staib, Michael [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    2017-09-21

    The GlueX experiment is a new experimental facility at Jefferson Lab in Newport News, VA. The experiment aims to map out the spectrum of hybrid mesons in the light quark sector. Measurements of the spin-density matrix elements in omega photoproduction are performed with a linear polarized photon beam on an unpolarized proton target, and presented in bins of Mandelstam t for beam energies of 8.4-9.0 GeV. The spin-density matrix elements are exclusively measured through two decays of the omega meson: omega -> pi^+ pi^- pi^0 and omega ->pi^0 gamma. A description of the experimental apparatus is presented. Several methods used in the calibration of the charged particle tracking system are described. These measurements greatly improve the world statistics in this energy range. These are the first results measured through the omega ->pi^0 gamma decay at this energy. Results are generally consistent with a theoretical model based on diffractive production with Pomeron and pseudoscalar exchange in the t-channel.

  14. Fabrication of ceramic oxide-coated SWNT composites by sol–gel process with a polymer glue

    International Nuclear Information System (INIS)

    Zhang Cheng; Gao Lei; Chen Yongming

    2011-01-01

    The functional copolymer bearing alkoxysilyl and pyrene groups, poly[3-(triethoxysilyl)propyl methacrylate]-co-[(1-pyrene-methyl) methacrylate] (TEPM 13 -co-PyMMA 3 ), was synthesized via atom transfer radical polymerization. Attributing the π–π interaction of pyrene units with the walls of single-walled carbon nanotubes (SWNTs), this polymer could disperse and exfoliate SWNTs in different solvents through physical interaction as demonstrated by TEM, UV/Vis absorption, and FT-IR analysis. The alkoxysilyl groups functionalized SWNTs were reacted with different inorganic precursors via sol–gel reaction, and, as a results, silica, titania, and alumina were coated onto the surface of SWNTs, respectively via copolymers as a molecular glue. The nanocomposites of ceramic oxides/SWNTs were characterized by SEM analysis. Dependent upon the feed, the thickness of inorganic coating can be tuned easily. This study supplies a facile and general way to coat SWNTs with ceramic oxides without deteriorating the properties of pristine SWNTs.

  15. Comparison of a plasma-based composite biologic sealant with fibrin glue (Tisseel) for vascular anastomoses.

    Science.gov (United States)

    Doillon, Charles J; Dion, Yves-Marie

    2004-12-01

    Biologic sealants are needed in numerous, more and more demanding, procedures--especially with developments occurring in endovascular and laparoscopic vascular techniques. An initial pilot study in dogs showed that a 4-cm aortotomy closed with a polyester patch sutured in place by a 4-mm-spaced running suture consistently led to massive hemorrhage. We then designed a study using five dogs where two aortotomies were done to compare the effect of Tisseel to that of an autologous sealant prepared in our laboratory. Arterial pressures and heparinization were maintained throughout the surgical procedure. Both biologic sealants prevented hemorrhage from the arteriotomy at unclamping. Macroscopic and histologic assessments were performed. At killing, one week later, the autologous sealant exhibited less blood saturation of the collagen sponge compared with Tisseel. The use of autologous plasma combined with other adhesive components could be an efficient alternative to allogenic fibrin glue. Further studies are needed to confirm these observations.

  16. Fabrication of ceramic oxide-coated SWNT composites by sol-gel process with a polymer glue

    Science.gov (United States)

    Zhang, Cheng; Gao, Lei; Chen, Yongming

    2011-09-01

    The functional copolymer bearing alkoxysilyl and pyrene groups, poly[3-(triethoxysilyl)propyl methacrylate]- co-[(1-pyrene-methyl) methacrylate] (TEPM13- co-PyMMA3), was synthesized via atom transfer radical polymerization. Attributing the π-π interaction of pyrene units with the walls of single-walled carbon nanotubes (SWNTs), this polymer could disperse and exfoliate SWNTs in different solvents through physical interaction as demonstrated by TEM, UV/Vis absorption, and FT-IR analysis. The alkoxysilyl groups functionalized SWNTs were reacted with different inorganic precursors via sol-gel reaction, and, as a results, silica, titania, and alumina were coated onto the surface of SWNTs, respectively via copolymers as a molecular glue. The nanocomposites of ceramic oxides/SWNTs were characterized by SEM analysis. Dependent upon the feed, the thickness of inorganic coating can be tuned easily. This study supplies a facile and general way to coat SWNTs with ceramic oxides without deteriorating the properties of pristine SWNTs.

  17. Nd:YAG laser double wavelength ablation of pollution encrustation on marble and bonding glues on duplicated painting canvas

    Science.gov (United States)

    Batishche, Sergei; Englezis, Apostolis; Gorovets, Tatiana; Kouzmouk, Andrei; Pilipenka, Uladzimir; Pouli, Paraskevi; Tatur, Hennady; Totou, Garyfallia; Ukhau, Viktar

    2005-07-01

    In the present study, a newly developed one-beam IR-UV laser cleaning system is presented. This system may be used for different applications in diverse fields, such as outdoors stonework conservation and canvas paintings restoration. The simultaneous use of the fundamental radiation of a Q-switched Nd:YAG laser at 1064 nm and its third harmonic at 355 nm was found appropriate to clean pollution crusts, while ensuring that no discoloration ("yellowing") would occur. The optimum ratio of UV to IR wavelengths in the final cleaning beam was investigated. In parallel, the same system was tested in diverse applications, such as the removal of bonding glues from duplicated canvases. The optimum laser parameters were investigated both on technical samples as well as on original paintings.

  18. Multivariate Analysis of the Predictors of Survival for Patients with Hepatocellular Carcinoma Undergoing Transarterial Chemoembolization: Focusing on Superselective Chemoembolization

    International Nuclear Information System (INIS)

    Ji, Suk Kyeong; Cho, Yun Ku; Ahn, Yong Sik; Kim, Mi Young; Park, Yoon Ok; Kim, Jae Kyun; Kim, Wan Tae

    2008-01-01

    While the prognostic factors of survival for patients with hepatocellular carcinoma (HCC) who underwent transarterial chemoembolization (TACE) are well known, the clinical significance of performing selective TACE for HCC patients has not been clearly documented. We tried to analyze the potential factors of disease-free survival for these patients, including the performance of selective TACE. A total of 151 patients with HCC who underwent TACE were retrospectively analyzed for their disease-free survival (a median follow- up of 23 months, range: 1-88 months). Univariate and multivariate analyses were performed for 20 potential factors by using the Cox proportional hazard model, including 19 baseline factors and one procedure-related factor (conventional versus selective TACE). The parameters that proved to be significant on the univariate analysis were subsequently tested with the multivariate model. Conventional or selective TACE was performed for 40 and 111 patients, respectively. Univariate and multivariate analyses revealed that tumor multiplicity, venous tumor thrombosis and selective TACE were the only three independent significant prognostic factors of disease-free survival (p = 0.002, 0.015 and 0.019, respectively). In our study, selective TACE was a favorable prognostic factor for the disease-free survival of patients with HCC who underwent TACE

  19. GLUE Analysis and Optimal Operation for Diyala River Basin in Iraq Using Variable Infiltration Capacity Model

    Science.gov (United States)

    Waheed, S., Sr.; Ramirez, J.

    2017-12-01

    Uncertainty in both hydrologic behavior and model characterization is a concern for current and future water resource system planning, operation, and management. To develop optimal dam operation schemes under future uncertainty, the sensitivity of the precipitation-runoff response to changes in hydro-climatic forcing must be quantified. To achieve this purpose, accurate (observational and modeled) data should be implemented. Herein, many data sources were compared to representative hydrologic datasets. Due to limited availability of observed daily data, a random temporal cascade method was used to downscale the monthly precipitation into daily. Then, four interpolation methods were compared to transform the point into gridded data. Furthermore, a regression technique coupled with Kriging method was developed. The method is based on regressing modeled data (from VIC dataset) with the observed gridded temperature by relating the regression to the geometry of each grid. The sensitivity and identifiability of the Variable Infiltration Capacity model (VIC) for the Diyala River basin in Iraq were evaluated using GLUE technique. Diyala River is a Tigris River tributary in eastern Iraq. Its total length and basin area are about 216.5 km and 16,763.7 km2, respectively. Seven candidate parameters of VIC model (b_infilt, Ds, Ws, Dsmax, and depths of soil layer 1, 2, and 3) associated with the infiltration and surface runoff production processes are examined for 14000 random sets. The comparison between the different data showed that neither the observations from Tropical Rainfall Measurement Mission nor the VIC modeled data is accurate for gridded precipitation; therefore, a downscaling technique was applied. Moreover, the comparison between four different interpolation techniques revealed that the Kriging method is the most accurate. The optimal model performance was found to be 0.731 NSCE. Also, the GLUE analysis results implied that the depth of the second soil layer depth

  20. Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger Egbert; Lin, MingDe; Duran, Rafael; Chapiro, Julius; Wang, Zhijun; Geschwind, Jean-François

    2015-01-01

    PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared to pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE

  1. Delayed-Phase Cone-Beam CT Improves Detectability of Intrahepatic Cholangiocarcinoma During Conventional Transarterial Chemoembolization

    Energy Technology Data Exchange (ETDEWEB)

    Schernthaner, Ruediger Egbert [The Johns Hopkins Hospital, Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology (United States); Lin, MingDe [Philips Research North America, Ultrasound and Interventions (United States); Duran, Rafael; Chapiro, Julius; Wang, Zhijun; Geschwind, Jean-François, E-mail: jfg@jhmi.edu [The Johns Hopkins Hospital, Russell H. Morgan Department of Radiology and Radiological Science, Division of Vascular and Interventional Radiology (United States)

    2015-08-15

    PurposeTo evaluate the detectability of intrahepatic cholangiocarcinoma (ICC) on dual-phase cone-beam CT (DPCBCT) during conventional transarterial chemoembolization (cTACE) compared to that of digital subtraction angiography (DSA) with respect to pre-procedure contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver.MethodsThis retrospective study included 17 consecutive patients (10 male, mean age 64) with ICC who underwent pre-procedure CE-MRI of the liver, and DSA and DPCBCT (early-arterial phase (EAP) and delayed-arterial phase (DAP)) just before cTACE. The visibility of each ICC lesion was graded by two radiologists on a three-rank scale (complete, partial, and none) on DPCBCT and DSA images, and then compared to pre-procedure CE-MRI.ResultsOf 61 ICC lesions, only 45.9 % were depicted by DSA, whereas EAP- and DAP-CBCT yielded a significantly higher detectability rate of 73.8 % and 93.4 %, respectively (p < 0.01). Out of the 33 lesions missed on DSA, 18 (54.5 %) and 30 (90.9 %) were revealed on EAP- and DAP-CBCT images, respectively. DSA depicted only one lesion that was missed by DPCBCT due to streak artifacts caused by a prosthetic mitral valve. DAP-CBCT identified significantly more lesions than EAP-CBCT (p < 0.01). Conversely, EAP-CBCT did not detect lesions missed by DAP-CBCT. For complete lesion visibility, DAP-CBCT yielded significantly higher detectability (78.7 %) compared to EAP (31.1 %) and DSA (21.3 %) (p < 0.01).ConclusionDPCBCT, and especially the DAP-CBCT, significantly improved the detectability of ICC lesions during cTACE compared to DSA. We recommend the routine use of DAP-CBCT in patients with ICC for per-procedure detectability and treatment planning in the setting of TACE.

  2. Trans-arterial chemoembolization (TACE) in patients with unresectable Hepatocellular carcinoma: Experience from a tertiary care centre in India

    Science.gov (United States)

    Paul, Shashi Bala; Gamanagatti, Shivanand; Sreenivas, Vishnubhatla; Chandrashekhara, Sheragaru Hanumanhtappa; Mukund, Amar; Gulati, Manpreet Singh; Gupta, Arun Kumar; Acharya, Subrat Kumar

    2011-01-01

    Aims: To evaluate the outcome following transarterial chemoembolization (TACE) and to identify the predictors of survival in patients with unresectable hepatocellular carcinoma (HCC). Material and Methods: HCC patients reporting to our hospital (2001-2007) were subjected to clinical, biochemical, and radiological examination. TACE was performed in those who fulfilled the inclusion criteria. Follow-up assessment was done with multiphase CT scan of the liver at 1, 3, and 6 months. Tumor response and survival rate were estimated. Univariate and multivariate analyses were done for determinants of survival. Results: A total of 73 patients (69 males, 4 females; mean age 49±13.4 years) were subjected to 123 sessions of TACE. The Child's classification was: A – 56 patients and B – 17 patients. Barcelona Clinic staging was: A – 20 patients, B – 38 patients, and C – 15 patients. Tumor size was ≤5cm in 28 (38%) patients, >5–10 cm in 28 (38%) patients, and >10 cm in 17 (23%) patients. Median follow-up was for 12 months (range: 1–77 months). No significant postprocedure complications were encountered. Overall survival rate was 66%, 47%, and 36.4% at 1, 2, and 3 years, respectively. Tumor size emerged as an important predictor of survival. Conclusion: TACE offers a reasonable palliative therapy for HCC. Initial tumor size is an independent predictor of survival. PMID:21799594

  3. Trans-arterial chemoembolization (TACE in patients with unresectable Hepatocellular carcinoma: Experience from a tertiary care centre in India

    Directory of Open Access Journals (Sweden)

    Shashi Bala Paul

    2011-01-01

    Full Text Available Aims: To evaluate the outcome following transarterial chemoembolization (TACE and to identify the predictors of survival in patients with unresectable hepatocellular carcinoma (HCC. Material and Methods: HCC patients reporting to our hospital (2001-2007 were subjected to clinical, biochemical, and radiological examination. TACE was performed in those who fulfilled the inclusion criteria. Follow-up assessment was done with multiphase CT scan of the liver at 1, 3, and 6 months. Tumor response and survival rate were estimated. Univariate and multivariate analyses were done for determinants of survival. Results: A total of 73 patients (69 males, 4 females; mean age 49±13.4 years were subjected to 123 sessions of TACE. The Child′s classification was: A - 56 patients and B - 17 patients. Barcelona Clinic staging was: A - 20 patients, B - 38 patients, and C - 15 patients. Tumor size was ≤5cm in 28 (38% patients, >5-10 cm in 28 (38% patients, and >10 cm in 17 (23% patients. Median follow-up was for 12 months (range: 1-77 months. No significant postprocedure complications were encountered. Overall survival rate was 66%, 47%, and 36.4% at 1, 2, and 3 years, respectively. Tumor size emerged as an important predictor of survival. Conclusion: TACE offers a reasonable palliative therapy for HCC. Initial tumor size is an independent predictor of survival.

  4. Trans-arterial chemoembolization (TACE) in patients with unresectable Hepatocellular carcinoma: Experience from a tertiary care centre in India

    International Nuclear Information System (INIS)

    Paul, Shashi Bala; Gamanagatti, Shivanand; Sreenivas, Vishnubhatla; Chandrashekhara, Sheragaru Hanumanhtappa; Mukund, Amar; Gulati, Manpreet Singh; Gupta, Arun Kumar; Acharya, Subrat Kumar

    2011-01-01

    To evaluate the outcome following transarterial chemoembolization (TACE) and to identify the predictors of survival in patients with unresectable hepatocellular carcinoma (HCC). HCC patients reporting to our hospital (2001-2007) were subjected to clinical, biochemical, and radiological examination. TACE was performed in those who fulfilled the inclusion criteria. Follow-up assessment was done with multiphase CT scan of the liver at 1, 3, and 6 months. Tumor response and survival rate were estimated. Univariate and multivariate analyses were done for determinants of survival. A total of 73 patients (69 males, 4 females; mean age 49±13.4 years) were subjected to 123 sessions of TACE. The Child's classification was: A – 56 patients and B – 17 patients. Barcelona Clinic staging was: A – 20 patients, B – 38 patients, and C – 15 patients. Tumor size was ≤5cm in 28 (38%) patients, >5–10 cm in 28 (38%) patients, and >10 cm in 17 (23%) patients. Median follow-up was for 12 months (range: 1–77 months). No significant postprocedure complications were encountered. Overall survival rate was 66%, 47%, and 36.4% at 1, 2, and 3 years, respectively. Tumor size emerged as an important predictor of survival. TACE offers a reasonable palliative therapy for HCC. Initial tumor size is an independent predictor of survival

  5. Ultrafine needle CO{sub 2} splenoportography: A comparative investigation with transarterial portography and MR portography

    Energy Technology Data Exchange (ETDEWEB)

    Teng Gaojun [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)]. E-mail: gjteng@vip.sina.com; Deng Gang [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Liu Zhensheng [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Fang Wen [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Zhu Guangyu [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Li Guozhao [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Guo Jinhe [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Shicheng [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Dong Yonghua [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)

    2006-09-15

    Purpose: To evaluate the safety and quality of CO{sub 2} splenoportography (CO{sub 2}-SP) by comparison to 3-dimensional dynamic contrast-enhanced magnetic resonance portography (3D-DCE-MRP) and transarterial portography (TAP). Materials and methods: CO{sub 2}-SP, 3D-DCE-MRP and TAP were performed within 3 days in 35 patients. CO{sub 2}-SP was conducted with a 26 G needle by puncture of spleen under fluoroscopy and/or ultrasound guidance. A fifty mm{sup 3} of CO{sub 2} was manually injected within 3 s. The safety and the side effects of CO{sub 2}-SP were assessed with a scoring system based on both the subjective feeling of patients questioned and the objective appearances of vital signs, electrocardiogram (ECG) and saturation of percutaneous blood oxygen (SpO{sub 2}). The quality of the imaging was compared among the three groups using different methods by a scoring criterion based on visualization of the portal branches. Results: Transient mild discomfortable reaction was present in 18 patients (51.4%). The scores measured for quality of portal vein branch visualization in the groups with CO{sub 2}-SP, 3D-DCE-MRP and TAP were 226, 196 and 167, respectively (P < 0.001, the higher of the scores, the better of the quality). The visibility of collateral veins was not significantly different amongst the three imaging techniques. Conclusion: Ultrafine needle CO{sub 2}-SP is safe and minimally invasive. The quality of CO{sub 2}-SP is better than that with 3D-DCE-MRP and TAP in terms of the visualizing portal vein branches.

  6. Radiotherapy Plus Transarterial Chemoembolization for Hepatocellular Carcinoma Invading the Portal Vein: Long-Term Patient Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Sang Min [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Lim, Young-Suk [Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Won, Hyung Jin [Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Jong Hoon, E-mail: jhkim2@amc.seoul.kr [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Kang Mo; Lee, Han Chu; Chung, Young-Hwa; Lee, Yung Sang [Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Lee, Sung Gyu [Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Park, Jin-hong [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Suh, Dong Jin [Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-04-01

    Purpose: We have evaluated the clinical outcomes of patients after transarterial chemoembolization (TACE) and 3-dimensional conformal radiotherapy for hepatocellular carcinoma (HCC) with portal vein tumor thrombosis (PVTT). Methods and Materials: A registry database of 412 patients treated with TACE and three-dimensional conformal radiotherapy for HCC with PVTT between August 2002 and August 2008 were analyzed retrospectively. The radiotherapy volume included the PVTT, with a 2- to 3-cm margin to cover adjacent HCC. Intrahepatic primary HCC was managed by TACE before or after radiotherapy. Results: Median patient age was 52 years old, and 88.1% of patients were male. Main or bilateral PVTT was observed in 200 (48.5%) patients. Median radiation dose was 40 Gy (range, 21-60 Gy) delivered in 2- to 5-Gy fractions. We found that 3.6% of patients achieved a complete response and that 24.3% of patients achieved a partial response. The response and progression-free rates of PVTT were 39.6% and 85.6%, respectively. Median patient survival was 10.6 months, and the 1- and 2-year survival rates were 42.5% and 22.8%, respectively. Significant independent variables associated with overall survival included advanced tumor stage, alpha-fetoprotein level, degree of PVTT, and response to radiotherapy. Forty-one patients (10.0%) showed grade 3-4 hepatic toxicity during or 3 months after completion of radiotherapy. Grades 2-3 gastroduodenal complications were observed in 15 patients (3.6%). Conclusions: Radiotherapy is a safe and effective treatment for PVTT in patients with HCC. These results suggested that the combination of TACE and radiotherapy is a treatment option for relieving and/or stabilizing PVTT in patients with advanced HCC.

  7. Predictive factors for early failure of transarterial embolization in blunt hepatic injury patients

    International Nuclear Information System (INIS)

    Lee, Y.-H.; Wu, C.-H.; Wang, L.-J.; Wong, Y.-C.; Chen, H.-W.; Wang, C.-J.; Lin, B.-C.; Hsu, Y.-P.

    2014-01-01

    Aim: To evaluate the early success of transarterial embolization (TAE) in patients with traumatic liver haemorrhage and to determine independent factors for its failure. Materials and methods: From January 2009 to December 2012, TAE was performed in 48 patients for traumatic liver haemorrhage. Their medical charts were reviewed for demographic information, pre-TAE vital signs and laboratory data, injury grade, type of contrast medium extravasation (CME) at CT, angiography findings, and early failure. “Early failure” was defined as the need for repeated TAE or a laparotomy for hepatic haemorrhage within 4 days after TAE. Variables were compared between the early success and early failure groups. Variables with univariate significance were also analysed using multivariate logistic regression for predictors of early failure. Results: Among 48 liver TAE cases, nine (18.8%) were early failures due to liver haemorrhage. Early failure was associated with injury grade (p = 0.039), major liver injury (grades 4 and 5; p = 0.007), multiple CMEs at angiography (p = 0.031), incomplete TAE (p = 0.002), and elevated heart rate (p = 0.026). Incomplete embolization (OR = 8; p = 0.042), and heart rate >110 beats/min (bpm; OR = 8; p = 0.05) were independent factors for early failure of TAE in the group with major liver injuries. Conclusion: Major hepatic injury is an important factor in early failure. Patients with a heart rate >110 bpm and incomplete embolization in the major injury group have an increased rate of early failure. The success rate of proximal TAE was comparable to that of the more time-consuming, superselective, distal TAE. - Highlights: • Early failure of TAE is associated with a higher grade of liver injury. • Incomplete embolization is more likely to suffer early failure of TAE. • A heart rate greater than 110 bpm is more likely to suffer early failure of TAE. • We recommend proximal embolization to prevent early failure of TAE

  8. Safety and efficacy of transarterial chemoembolization with degradable starch microspheres (DSM-TACE) in the treatment of secondary liver malignancies.

    Science.gov (United States)

    Schicho, Andreas; Pereira, Philippe L; Michalik, Katharina; Beyer, Lukas P; Stroszczynski, Christian; Wiggermann, Philipp

    2018-01-01

    To evaluate the safety and efficacy of degradable starch microspheres (DSM) as embolic agents in transarterial chemoembolization (TACE) in the treatment of secondary liver metastases. This was a national, multicenter observational study. Primary endpoints were safety and treatment response according to Modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria. A total of 77 DSM-TACE procedures were performed in 20 patients. Minor immediate adverse events (AEs) were epigastric pain with an incidence of 45.5% (35/77), and nausea and vomiting at an incidence of 23.4% (18/77). Delayed minor AEs were epigastric pain in 13/77 (16.9%) treatments and nausea and vomiting in 10 (13.0%) treatments. No severe AEs were documented. Therapeutic efficacy of DSM-TACE procedures according to mRECIST was as follows: complete response 0/77, partial response 17/77, stable disease 33/77 and progressive disease 6/77, no data was available for 21/77 treatments. Overall, objective response was achieved in 8 of 20 patients (40.0%). DSM as embolic agent for TACE is safe in the treatment of liver metastases. An objective response in 40.0% of patients and disease control in 64.9% of procedures was achieved, and this should lead to further evaluation of DSM-TACE as treatment option for nonresectable liver metastases.

  9. Serum Gamma-Glutamyl-Transferase Independently Predicts Outcome After Transarterial Chemoembolization of Hepatocellular Carcinoma: External Validation

    Energy Technology Data Exchange (ETDEWEB)

    Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr; Deschamps, Frederic [Institut Gustave Roussy, Department of Interventional Radiology (France); Boulin, Mathieu [University Hospital, INSERM U866 (France); Boige, Valerie; Malka, David; Ducreux, Michel [Institut Gustave Roussy, Department of Digestive Oncology (France); Hillon, Patrick [University Hospital, INSERM U866 (France); Baere, Thierry de [Institut Gustave Roussy, Department of Interventional Radiology (France)

    2012-10-15

    Purpose: An Asian study showed that gamma glutamyl transpeptidase (GGT) can predict survival after transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). This study was designed to validate in a European population this biomarker as an independent predictor of outcome after TACE of HCC and to determine a threshold value for clinical use. Methods: In 88 consecutive patients treated by TACE for HCC, the optimal threshold for GGT serum level was determined by a ROC analysis. Endpoints were time-to-treatment failure (TTTF) and overall survival (OS). All multivariate models were internally validated using bootstrapping (90 replications). Results: Median follow-up lasted 373 days, and median overall survival was 748 days. The optimal threshold for GGT was 165 U/L (sensitivity: 89.3%; specificity: 56.7%; area under the ROC curve: 0.7515). Median TTTF was shorter when GGT was {>=}165 U/L (281 days vs. 850 days; P < 0.001). GGT {>=}165 U/L (hazard ratio (HR) = 2.06; P = 0.02), WHO PS of 2 (HR = 5.4; P = 0.002), and tumor size (HR = 1.12; P = 0.014) were independently associated with shorter TTTF. Median OS was shorter when GGT was {>=}165 U/L (508 days vs. not reached; P < 0.001). GGT {>=} 165 U/L (HR = 3.05; P = 0.029), WHO PS of 2 (HR = 12.95; P < 0.001), alfa-fetoprotein (HR = 2.9; P = 0.01), and tumor size (HR = 1.096; P = 0.013) were independently associated with shorter OS. The results were confirmed by bootstrapping. Conclusions: Our results provide in a European population the external validation of GGT as an independent predictor of outcome after TACE of HCC. A serum level of GGT {>=} 165 U/L is independently associated with both shorter TTTF and OS.

  10. Serum Gamma-Glutamyl-Transferase Independently Predicts Outcome After Transarterial Chemoembolization of Hepatocellular Carcinoma: External Validation

    International Nuclear Information System (INIS)

    Guiu, Boris; Deschamps, Frédéric; Boulin, Mathieu; Boige, Valérie; Malka, David; Ducreux, Michel; Hillon, Patrick; Baère, Thierry de

    2012-01-01

    Purpose: An Asian study showed that gamma glutamyl transpeptidase (GGT) can predict survival after transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). This study was designed to validate in a European population this biomarker as an independent predictor of outcome after TACE of HCC and to determine a threshold value for clinical use. Methods: In 88 consecutive patients treated by TACE for HCC, the optimal threshold for GGT serum level was determined by a ROC analysis. Endpoints were time-to-treatment failure (TTTF) and overall survival (OS). All multivariate models were internally validated using bootstrapping (90 replications). Results: Median follow-up lasted 373 days, and median overall survival was 748 days. The optimal threshold for GGT was 165 U/L (sensitivity: 89.3%; specificity: 56.7%; area under the ROC curve: 0.7515). Median TTTF was shorter when GGT was ≥165 U/L (281 days vs. 850 days; P < 0.001). GGT ≥165 U/L (hazard ratio (HR) = 2.06; P = 0.02), WHO PS of 2 (HR = 5.4; P = 0.002), and tumor size (HR = 1.12; P = 0.014) were independently associated with shorter TTTF. Median OS was shorter when GGT was ≥165 U/L (508 days vs. not reached; P < 0.001). GGT ≥ 165 U/L (HR = 3.05; P = 0.029), WHO PS of 2 (HR = 12.95; P < 0.001), alfa-fetoprotein (HR = 2.9; P = 0.01), and tumor size (HR = 1.096; P = 0.013) were independently associated with shorter OS. The results were confirmed by bootstrapping. Conclusions: Our results provide in a European population the external validation of GGT as an independent predictor of outcome after TACE of HCC. A serum level of GGT ≥ 165 U/L is independently associated with both shorter TTTF and OS.

  11. Transarterial Chemoembolization for Hepatocellular Carcinomas with Central Bile Duct Invasion: Safety, Prognosis, and Predictive Factors

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Chung, Jin Wook, E-mail: chungjw@snu.ac.kr [Seoul National University Hospital, Department of Radiology (Korea, Republic of); Cho, Yun Ku [VHS Medical Center, Department of Radiology (Korea, Republic of); Kim, Yoon Jun; Yoon, Jung-Hwan [Seoul National University Hospital, Department of Internal Medicine (Korea, Republic of); Kim, Hyo-Cheol; Jae, Hwan Jun [Seoul National University Hospital, Department of Radiology (Korea, Republic of)

    2015-08-15

    PurposeTo assess the safety and effectiveness of transarterial chemoembolization (TACE) of patients who have hepatocellular carcinomas (HCCs) with central bile duct invasion.Materials and MethodsThe institutional review board approved this retrospective study and waived informed consent. Fifty-three patients, initially treated with TACE for HCCs with central bile duct invasion from January 1999 to September 2012, were included. Clinical, laboratory, and survival data were reviewed. Complications and hospitalization length were evaluated using the χ{sup 2} test, Fisher’s exact test, and logistic regression analysis. Survival was analyzed using the Kaplan–Meier method with log-rank test and Cox proportional hazard model.ResultsSeven patients experienced TACE-related major complications (severe post-embolization syndrome in 3, non-fatal sepsis in 3, and secondary bacterial peritonitis in 1). The overall major complication rate was 13.2 %, but there were no permanent adverse sequelae or deaths within 30 days. Serum total bilirubin ≥3.0 mg/dL was the only significant risk factor for long hospitalization [hazard ratio (HR) = 4.341, p = .022]. The median survival was 12.2 months. Extrahepatic metastasis (HR = 6.145, p < .001), international normalized ratio (PT-INR) ≥1.20 (HR = 4.564, p < .001), vascular invasion (HR = 3.484, p = .001), and intermediate tumor enhancement (HR = 2.417, p = .019) were significantly associated with shorter survival.ConclusionTACE can be a safe and effective treatment for patients who have HCCs with central bile duct invasion. In particular, long-term survival can be expected if patients have strongly enhancing tumors without poor prognostic factors such as extrahepatic metastasis, PT-INR prolongation, and vascular invasion.

  12. Development of the Tagger Microscope & Analysis of Spin Density Matrix Elements in gamma-p -> phi-p for the GlueX Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Alexander E. [Carnegie Mellon Univ., Pittsburgh, PA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-05-31

    The quark model has been successful in classifying the spectrum of mesons observed since the 1960s, however, it fails to explain some of the measured bound states. Lattice QCD predictions have shown that an excited gluonic field may contribute to the quantum numbers of the bound state and form hybrid mesons, qq-bar-g, where g is a constituent gluon. It is possible for some hybrids to possess quantum numbers forbidden by the quark model and are known as \\smoking gun" hybrids due to their lack of mixing with conventional qq-bar states. The GlueX photoproduction experiment at Jefferson Lab in Newport News, VA is designed to study hybrid mesons and to map their spectrum. A 12 GeV electron beam produces 9 GeV linearly polarized photons via coherent bremsstrahlung in a diamond radiator which are incident on a liquid H2 target. In order to determine the photon energy, the use of a tagging spectrometer which measures the energy of the post-bremsstrahlung electron is required. The tagger microscope is a scintillating fiber detector designed to measure the energy of electrons corresponding to the polarized photons. The main focus of this work is the design and construction of the tagger microscope electronics as well as the calibration of the microscope within the experiment. Additionally, the analysis of the reaction gamma-p -> phi-p, where phi (1020) -> K+K-, is discussed. This analysis provides a high-level calibration for GlueX in regards to understanding the acceptance and sensitivity of the detectors to mesons with strange quark content. By studying the phi with linearly polarized photons, information on the production mechanism can be extracted. The measurement of the phi spin-density matrix elements are shown and compared with past data which are found to be in agreement.

  13. Liver and biliary damages following transarterial chemoembolization of hepatocellular carcinoma: comparison between drug-eluting beads and lipiodol emulsion

    Energy Technology Data Exchange (ETDEWEB)

    Monier, Arnaud; Duran, Rafael; Bize, Pierre; Dunet, Vincent; Denys, Alban [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Guiu, Boris [Lausanne University Hospital, Department of Diagnostic and Interventional Radiology, Lausanne (Switzerland); Montpellier University Hospital, Department of Diagnostic and Interventional Radiology, Montpellier (France); Aho, Serge [University Hospital, Department of Epidemiology, Dijon (France); Deltenre, Pierre [Lausanne University Hospital, Department of Gastroenterology, Lausanne (Switzerland)

    2017-04-15

    To compare transarterial chemoembolization (TACE)-related hepatic toxicities of conventional TACE (cTACE) and drug-eluting beads TACE (DEB-TACE) in patients with intermediate-stage hepatocellular carcinoma. In this retrospective study, 151 consecutive patients undergoing cTACE or DEB-TACE and MRI 3-6 weeks before and after therapy were included. Toxicity was assessed on imaging (global hepatic damages (GHD), overall biliary injuries, biliary cast, bile duct dilatation, intrahepatic biloma, portal thrombosis), and clinico-biological follow-ups. Tumour response, time to progression (TTP), and overall survival were assessed. Factors influencing complication rate were identified by generalized equation logistic regression model. Biliary injuries and intrahepatic biloma incidence were significantly higher following DEB-TACE (p < 0.001). DEB-TACE showed a significant increased risk of GHD (OR: 3.13 [1.74-5.63], p < 0.001) and biliary injuries (OR: 4.53 [2.37-8.67], p < 0.001). A significant relationship was found between baseline prothrombin value and GHD, biliary injuries and intrahepatic biloma (all p < 0.01), and between the dose of chemotherapy and intrahepatic biloma (p = 0.001). Only TTP was significantly shorter following DEB-TACE compared to cTACE (p = 0.025). DEB-TACE was associated with increased hepatic toxicities compared to cTACE. GHD, biliary injuries, and intrahepatic biloma were more frequently observed with high baseline prothrombin value, suggesting that cTACE might be more appropriate than DEB-TACE in patients with less advanced cirrhosis. (orig.)

  14. Baseline Tumor Lipiodol Uptake after Transarterial Chemoembolization for Hepatocellular Carcinoma: Identification of a Threshold Value Predicting Tumor Recurrence.

    Science.gov (United States)

    Matsui, Yusuke; Horikawa, Masahiro; Jahangiri Noudeh, Younes; Kaufman, John A; Kolbeck, Kenneth J; Farsad, Khashayar

    2017-12-01

    The aim of the study was to evaluate the association between baseline Lipiodol uptake in hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) with early tumor recurrence, and to identify a threshold baseline uptake value predicting tumor response. A single-institution retrospective database of HCC treated with Lipiodol-TACE was reviewed. Forty-six tumors in 30 patients treated with a Lipiodol-chemotherapy emulsion and no additional particle embolization were included. Baseline Lipiodol uptake was measured as the mean Hounsfield units (HU) on a CT within one week after TACE. Washout rate was calculated dividing the difference in HU between the baseline CT and follow-up CT by time (HU/month). Cox proportional hazard models were used to correlate baseline Lipiodol uptake and other variables with tumor response. A receiver operating characteristic (ROC) curve was used to identify the optimal threshold for baseline Lipiodol uptake predicting tumor response. During the follow-up period (mean 5.6 months), 19 (41.3%) tumors recurred (mean time to recurrence = 3.6 months). In a multivariate model, low baseline Lipiodol uptake and higher washout rate were significant predictors of early tumor recurrence ( P = 0.001 and Baseline Lipiodol uptake and washout rate on follow-up were independent predictors of early tumor recurrence. A threshold value of baseline Lipiodol uptake > 270.2 HU was highly sensitive and specific for tumor response. These findings may prove useful for determining subsequent treatment strategies after Lipiodol TACE.

  15. Trans-arterial xenotransplantation (Tx) of newborn porcine islet (NPI). A clinic trial for type I diabetes

    International Nuclear Information System (INIS)

    Wang Wei; Mo Zhaohui; Huang Zufa; Luo Xianming; Liu Sheng; Ye Bin; Li Bing; Liu Yingxin

    2002-01-01

    Objective: Liver is an important site to host transplanted islets, and implanting of islets by hepatic artery is simpler than by portal vein. Authors' study evaluated efficiency of the method and possible complication in a clinical setting. Methods: From October 1998 to June 2000, 4 type I diabetic patients received 4 x 10 6 (2 cases) and 8 x 10 6 (2 cases) of NPI through hepatic artery. Before Tx, all cases had the history with ketosis and acidosis. Exogenous insulin doses used for these cases were 25-48 units and their GHb was 9%-11%. After Tx, the NPI recipients were treated with immunosuppressants including cyclosporin 8 mg/kg for 12 months, cellcept 2 g/d for 25 days, and methylprednisolone 500 mg at 1 st day, then reduced to 50 mg for 3 days until to 10 mg for 1 month. Liver function and CD4/CD8 of the recipients were measured before and after Tx. Results: After Tx, the dose of exogenous insulin was increased to 60 mg due to methylprednisolone treatment. When methylprednisolone dose was decreased, the requirement for insulin was reduced to 32%-58% of the dose used before Tx. The reduction of required insulin for NPI recipients was proportional to the number of implanted NPI. In addition, GHb was also reduced to normal level (4%-6%) 3 months after Tx. No significant alterations of liver function and CD4 and CD8 in blood were observed after Tx. Conclusion: Trans-arterial intro-hepatic xenotransplantation of NPI is an efficient and safe therapeutic method for type I diabetes. Combination of cyclosporin, cellcept, and methylprednisolone is an effective immunosuppressive strategy for NPI xenograft transplantation

  16. A Comparison of Three Transarterial Lipiodol-Based Formulations for Hepatocellular Carcinoma: In Vivo Biodistribution Study in Humans

    International Nuclear Information System (INIS)

    Yu, Simon Chun Ho; Leung, Thomas Wai Tong; Lau, Wan Yee; Lee, Nelson; Hui, Edwin Pun; Yeo, Winnie; Lai, Paul Bo San; Mok, Tony Shu Kam

    2008-01-01

    This study aimed to evaluate and compare the biodistribution properties of three transarterial Lipiodol-based therapeutic regimens in human hepatocellular carcinoma (HCC). In this prospective study with 13 patients randomly allocated to one of three study groups, each of the patients received transcatheter intra-arterial administration into a solitary HCC with one of three different Lipiodol-based formulations: Lipiodol-ethanol mixture (LEM; Group A), Lipiodol alone (Group B), and Lipiodol and gelatin pledgets (Group C). With the use of radioactive iodine-131-labeled Lipiodol, each group was assessed for (1) pattern of Lipiodol accumulation in the lungs within the first 2 weeks as evaluated by single-photon emission computed tomography and (2) decomposition of Lipiodol formulation within the first 2 weeks as evaluated by radioactivity detected in peripheral blood and urine. The degree of Lipiodol retention in the tumor within the first 4 weeks was evaluated with CT. No statistically significant difference in Lipiodol accumulation in the lungs was detected among the three groups. However, the peak accumulation in the lungs was delayed 3 days for Group A compared to Groups B and C. The degree of Lipiodol retention within the tumor in Group A was significantly greater than that in Groups B and C on day 14 (p = 0.014) and day 28 (p = 0.013). This study showed that LEM is associated with a greater embolic effect in intrahepatic HCC at 4 weeks, and a comparable degree of lung shunting and decomposition rates, compared with ethanol-free Lipiodol formulations

  17. Stereotactic body radiation therapy with or without transarterial chemoembolization for patients with primary hepatocellular carcinoma: preliminary analysis

    International Nuclear Information System (INIS)

    Choi, Byung Ock; Choi, Ihl Bohng; Jang, Hong Seok; Kang, Young Nam; Jang, Ji Sun; Bae, Si Hyun; Yoon, Seung Kew; Chai, Gyu Young; Kang, Ki Mun

    2008-01-01

    The objectives of this retrospective study was to evaluate the efficacy of stereotactic body radiation therapy (SBRT) for small non-resectable hepatocellular carcinoma (HCC) and SBRT combined with transarterial chemoembolization (TACE) for advanced HCC with portal vein tumor thrombosis (PVTT). Thirty one patients with HCC who were treated with SBRT were used for the study. We studied 32 HCC lesions, where 23 lesions (22 patients) were treated targeting small non-resectable primary HCC, and 9 lesions (9 patients) targeting PVTT using the Cyberknife. All the 9 patients targeting PVTT received TACE for the advanced HCC. Tumor volume was 3.6–57.3 cc (median, 25.2 cc) and SBRT dose was 30–39 Gy (median, 36 Gy) in 3 fractions for consecutive days for 70–85% of the planned target volume. The median follow up was 10.5 months. The overall response rate was 71.9% [small HCC: 82.6% (19/23), advanced HCC with PVTT: 44.4% (4/9)], with the complete and partial response rates of 31.3% [small HCC: 26.1% (6/23), advanced HCC with PVTT: 11.1% (1/9)], and 50.0% [small HCC: 56.5% (13/23), advanced HCC with PVTT: 33.3% (3/9)], respectively. The median survival period of small HCC and advanced HCC with PVTT patients was 12 months and 8 months, respectively. No patient experienced Grade 4 toxicity. SBRT for small HCC and SBRT combined with TACE for advanced HCC with PVTT showed feasible treatment modalities with minimal side effects in selected patients with primary HCC

  18. Impact of the activity calculation method used in transarterial radioembolization: a dosimetric comparison between 90Y-SIRSphere and 90Y-TheraSphere therapy.

    Science.gov (United States)

    Jha, Ashish K; Mithun, Sneha; Purandare, Nilendu C; Shah, Sneha A; Agrawal, Archi; Kulkarni, Suyash S; Shetty, Nitin; Rangarajan, Venkatesh

    2016-09-01

    Transarterial radioembolization is used to treat primary and secondary liver malignancies. Two commercially available drugs are utilized for the purpose. The aim of our study is to compare the radiation dose delivered to the tumor by these drugs. This study included 86 patients (M : F - 7.6 : 1, median age=50.5 years), 46 patients were treated by Y-TheraSphere and 42 patients were treated by Y-SIRSphere. Activity administered in Y-TheraSphere and Y-SIRSphere was calculated using a modified partition model and a modified body surface area model, respectively. The radiation dose delivered by two drugs was calculated and compared in our study. Activity administered in Y-TheraSphere was significantly higher than that of Y-SIRSphere. Hence, the radiation dose delivered to the tumor by Y-SIRSphere was significantly lower (58.4%) than that of Y-TheraSphere (P=0.000). As the radiation dose delivered by Y-SIRSphere was lower than Y-TheraSphere, we believe that the formula for Y-SIRSphere activity calculation needs to be modified so that the optimal dose can be delivered to the tumor.

  19. CT-guided Irreversible Electroporation in an Acute Porcine Liver Model: Effect of Previous Transarterial Iodized Oil Tissue Marking on Technical Parameters, 3D Computed Tomographic Rendering of the Electroporation Zone, and Histopathology

    International Nuclear Information System (INIS)

    Sommer, C. M.; Fritz, S.; Vollherbst, D.; Zelzer, S.; Wachter, M. F.; Bellemann, N.; Gockner, T.; Mokry, T.; Schmitz, A.; Aulmann, S.; Stampfl, U.; Pereira, P.; Kauczor, H. U.; Werner, J.; Radeleff, B. A.

    2015-01-01

    PurposeTo evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance.MethodsAfter Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann–Whitney test. Histopathological differences were assessed.ResultsMean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm 3 , and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm 3 , and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone.ConclusionThere is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver

  20. CT-guided Irreversible Electroporation in an Acute Porcine Liver Model: Effect of Previous Transarterial Iodized Oil Tissue Marking on Technical Parameters, 3D Computed Tomographic Rendering of the Electroporation Zone, and Histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Fritz, S., E-mail: stefan.fritz@med.uni-heidelberg.de [University Hospital Heidelberg, Department of General Visceral and Transplantation Surgery (Germany); Vollherbst, D., E-mail: dominikvollherbst@web.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Zelzer, S., E-mail: s.zelzer@dkfz-heidelberg.de [German Cancer Research Center (dkfz), Medical and Biological Informatics (Germany); Wachter, M. F., E-mail: fredericwachter@googlemail.com; Bellemann, N., E-mail: nadine.bellemann@med.uni-heidelberg.de; Gockner, T., E-mail: theresa.gockner@med.uni-heidelberg.de; Mokry, T., E-mail: theresa.mokry@med.uni-heidelberg.de; Schmitz, A., E-mail: anne.schmitz@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Aulmann, S., E-mail: sebastian.aulmann@mail.com [University Hospital Heidelberg, Department of General Pathology (Germany); Stampfl, U., E-mail: ulrike.stampfl@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Pereira, P., E-mail: philippe.pereira@slk-kliniken.de [SLK Kliniken Heilbronn GmbH, Clinic for Radiology, Minimally-invasive Therapies and Nuclear Medicine (Germany); Kauczor, H. U., E-mail: hu.kauczor@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany); Werner, J., E-mail: jens.werner@med.uni-heidelberg.de [University Hospital Heidelberg, Department of General Visceral and Transplantation Surgery (Germany); Radeleff, B. A., E-mail: boris.radeleff@med.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2015-02-15

    PurposeTo evaluate the effect of previous transarterial iodized oil tissue marking (ITM) on technical parameters, three-dimensional (3D) computed tomographic (CT) rendering of the electroporation zone, and histopathology after CT-guided irreversible electroporation (IRE) in an acute porcine liver model as a potential strategy to improve IRE performance.MethodsAfter Ethics Committee approval was obtained, in five landrace pigs, two IREs of the right and left liver (RL and LL) were performed under CT guidance with identical electroporation parameters. Before IRE, transarterial marking of the LL was performed with iodized oil. Nonenhanced and contrast-enhanced CT examinations followed. One hour after IRE, animals were killed and livers collected. Mean resulting voltage and amperage during IRE were assessed. For 3D CT rendering of the electroporation zone, parameters for size and shape were analyzed. Quantitative data were compared by the Mann–Whitney test. Histopathological differences were assessed.ResultsMean resulting voltage and amperage were 2,545.3 ± 66.0 V and 26.1 ± 1.8 A for RL, and 2,537.3 ± 69.0 V and 27.7 ± 1.8 A for LL without significant differences. Short axis, volume, and sphericity index were 16.5 ± 4.4 mm, 8.6 ± 3.2 cm{sup 3}, and 1.7 ± 0.3 for RL, and 18.2 ± 3.4 mm, 9.8 ± 3.8 cm{sup 3}, and 1.7 ± 0.3 for LL without significant differences. For RL and LL, the electroporation zone consisted of severely widened hepatic sinusoids containing erythrocytes and showed homogeneous apoptosis. For LL, iodized oil could be detected in the center and at the rim of the electroporation zone.ConclusionThere is no adverse effect of previous ITM on technical parameters, 3D CT rendering of the electroporation zone, and histopathology after CT-guided IRE of the liver.

  1. Growth characteristics and imaging properties of the morris hepatoma 3924a in ACI rats: A suitable model for transarterial chemoembolization

    International Nuclear Information System (INIS)

    Truebenbach, Jochen; Graepler, Florian; Pereira, Philippe L; Ruck, Peter; Lauer, Ulrich; Gregor, Michael; Claussen, Claus-D.; Huppert, Peter E.

    2000-01-01

    Purpose: For experimental studies investigating modalities and efficacy of transarterial chemoembolization (TACE) in hepatocellular carcinoma (HCC) an animal model resembling the human situation as closely as possible would be appropriate. Specifically, reproducible tumor growth characteristics with the capability for appropriate in vivo imaging to monitor treatment efficacy are required.Methods: Morris hepatoma 3924A was implanted into the liver of 30 ACI rats. Tumor growth was followed by angiography (n=10), ultrasound (US, n=30), native computed tomography (CT. n=16), and native magnetic resonance imaging (MRU n=30) between day 8 and day 36 after implantation. The radiological morphological characteristics were compared with the macroscopic and microscopic histological findings of the explanted tumors.Results: In all 30 animals a solitary liver tumor was found and macroscopically no signs of metastases, ascites, or peritoneal tumor were visible. On histopathological examination tumor sizes ranged between 27 ± 3 mm 3 (day 8) and 3468 ± 79 mm 3 (day 36). The first signs of tumor necrosis occurred at day 16. US allowed tumor visualization from day 8, MRI from day 8, angiography from day 10, and CT from day 14.Conclusions: The tumor model has the potential to be used for the visualization of tumor growth by MRI and US. The potential for monitoring therapeutic effects of TACE needs to be investigated.

  2. Endolymphatic Ethiodized Oil Intranodal Lymphangiography and Cyanoacrylate Glue Embolization for the Treatment of Postoperative Lymphatic Leak After Robot-Assisted Laparoscopic Pelvic Resection.

    Science.gov (United States)

    Hill, Hannah; Srinivasa, Ravi N; Gemmete, Joseph J; Hage, Anthony; Bundy, Jacob; Chick, Jeffrey Forris Beecham

    2018-01-01

    Purpose: To report the approach, technical success, clinical outcomes, complications, and follow-up of ethiodized oil intranodal lymphangiography with cyanoacrylate glue embolization for the treatment of lymphatic leak after robot-assisted laparoscopic pelvic resection. Materials and Methods: Four men with mean age 68.7 ± 14.3 years were treated with ethiodized oil intranodal lymphangiography with cyanoacrylate embolization for postoperative lymphatic leak. Patients underwent either (1) cystoprostatectomy with ileal conduit and bilateral extensive pelvic lymph node dissection for muscle-invasive urothelial carcinoma and presented with postoperative lymphatic ascites ( n  = 2) or (2) prostatectomy with bilateral standard pelvic lymph node dissection for prostate carcinoma and presented with postoperative pelvic lymphoceles ( n  = 2). Intranodal lymphangiography and embolization procedural details, technical success, clinical outcomes, and follow-up were recorded. Results: In four patients, a total of six ethiodized oil intranodal lymphangiograms were performed, two procedures being repeated interventions. Inguinal lymph node catheterization and ethiodized oil lymphangiography was technically effective in all procedures. A mean of 5.2 ± 2.0 mL of ethiodized oil was used for lymphatic opacification. Cyanoacrylate was diluted to 24.2% with ethiodized oil and 0.44 mL of cyanoacrylate was instilled during first time interventions. On repeat procedures, cyanoacrylate was diluted to 51.7%, and 0.52 mL was instilled. The primary clinical success rate was 50% ( n  = 2/4). Clinical success was achieved in all patients after two interventions ( n  = 4; 100%). No complications were reported at mean follow-up of 134.7 ± 79.2 days (range: 59-248 days). Conclusion: Ethiodized oil intranodal lymphangiography with direct cyanoacrylate glue embolization is a minimally invasive treatment option for lymphatic leak after pelvic resection.

  3. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine

    Science.gov (United States)

    2012-01-01

    Background Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. Methods rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. Results rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Conclusions Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media. PMID:22453050

  4. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine.

    Science.gov (United States)

    Kahlert, Philipp; Parohl, Nina; Albert, Juliane; Schäfer, Lena; Reinhardt, Renate; Kaiser, Gernot M; McDougall, Ian; Decker, Brad; Plicht, Björn; Erbel, Raimund; Eggebrecht, Holger; Ladd, Mark E; Quick, Harald H

    2012-03-27

    Real-time cardiovascular magnetic resonance (rtCMR) is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI) using the nitinol-based Medtronic CoreValve bioprosthesis. rtCMR-guided transfemoral (n = 2) and transsubclavian (n = 6) TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.

  5. Towards real-time cardiovascular magnetic resonance guided transarterial CoreValve implantation: in vivo evaluation in swine

    Directory of Open Access Journals (Sweden)

    Kahlert Philipp

    2012-03-01

    Full Text Available Abstract Background Real-time cardiovascular magnetic resonance (rtCMR is considered attractive for guiding TAVI. Owing to an unlimited scan plane orientation and an unsurpassed soft-tissue contrast with simultaneous device visualization, rtCMR is presumed to allow safe device navigation and to offer optimal orientation for precise axial positioning. We sought to evaluate the preclinical feasibility of rtCMR-guided transarterial aortic valve implatation (TAVI using the nitinol-based Medtronic CoreValve bioprosthesis. Methods rtCMR-guided transfemoral (n = 2 and transsubclavian (n = 6 TAVI was performed in 8 swine using the original CoreValve prosthesis and a modified, CMR-compatible delivery catheter without ferromagnetic components. Results rtCMR using TrueFISP sequences provided reliable imaging guidance during TAVI, which was successful in 6 swine. One transfemoral attempt failed due to unsuccessful aortic arch passage and one pericardial tamponade with subsequent death occurred as a result of ventricular perforation by the device tip due to an operating error, this complication being detected without delay by rtCMR. rtCMR allowed for a detailed, simultaneous visualization of the delivery system with the mounted stent-valve and the surrounding anatomy, resulting in improved visualization during navigation through the vasculature, passage of the aortic valve, and during placement and deployment of the stent-valve. Post-interventional success could be confirmed using ECG-triggered time-resolved cine-TrueFISP and flow-sensitive phase-contrast sequences. Intended valve position was confirmed by ex-vivo histology. Conclusions Our study shows that rtCMR-guided TAVI using the commercial CoreValve prosthesis in conjunction with a modified delivery system is feasible in swine, allowing improved procedural guidance including immediate detection of complications and direct functional assessment with reduction of radiation and omission of contrast media.

  6. Cinnamic Acid Derivatives Enhance the Efficacy of Transarterial Embolization in a Rat Model of Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, Luke R., E-mail: lrw6n@virginia.edu [University of Virginia Health Systems, Department of Radiology and Medical Imaging (United States); Brautigan, David L., E-mail: db8g@virginia.edu [University of Virginia, Department of Microbiology, Immunology, and Cancer Biology (United States); Wu, Hanping, E-mail: hanpingwumd@gmail.com [University Hospitals of Cleveland, Case Western Reserve University, Department of Radiology (United States); Yarmohammadi, Hooman, E-mail: yar.hooman@gmail.com [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Kubicka, Ewa, E-mail: emk6d@virginia.edu [University of Virginia, Department of Microbiology, Immunology, and Cancer Biology (United States); Serbulea, Vlad, E-mail: vs9ck@virginia.edu; Leitinger, Norbert, E-mail: nl2q@virginia.edu [University of Virginia, Department of Pharmacology (United States); Liu, Wendy, E-mail: wendy.liu@uhhospitals.org [University Hospitals of Cleveland, Case Western Reserve University, Department of Pathology (United States); Haaga, John R., E-mail: john.haaga@uhhospitals.org [University Hospitals of Cleveland, Case Western Reserve University, Department of Radiology (United States)

    2017-03-15

    IntroductionWe hypothesize that the combination of transarterial embolization (TAE) plus inhibition of lactate export will limit anaerobic metabolism and reduce tumor survival compared to TAE alone. The purpose of this study was to test this hypothesis in a rat model of hepatocellular carcinoma (HCC).MethodsRat N1-S1 hepatoma cells were assayed in vitro using the Seahorse XF analyzer to measure extracellular acidification (lactate excretion) comparing effects of the addition of caffeic acid (CA) or ferulic acid (FA) or UK-5099 with control. Monocarboxylate transporter Slc16a3 was knocked down by RNAi. N1S1 tumors were orthotopically implanted in rats and 4 groups evaluated: (1) Control, (2) TAE-only, (3) TAE plus CA, and (4) TAE plus FA. Tumor size was determined by ultrasound and analyzed by repeated measures statistics. Tumors harvested at 4 weeks were examined by microscopy.ResultsSeahorse assays showed that CA and FA caused a significant reduction by >90% in lactate efflux by N1S1 tumor cells (p < 0.01). Knockdown of Slc16a3 prevented inhibition by CA. In vivo tumors grew 30-fold in volume over 4 weeks in untreated controls. By comparison, TAE resulted in near cessation of growth (10% in 4-week time period). However, both TAE + CA and TAE + FA caused a significant reduction of tumor volumes (87 and 72%, respectively) compared to control and TAE (p < 0.05). Pathologic evaluation revealed residual tumor in the TAE group but no residual viable tumor cells in the TAE + CA and TAE + FA groups.ConclusionAddition of CA or FA enhances the effectiveness of TAE therapy for HCC in part by blocking lactate efflux.

  7. Cinnamic Acid Derivatives Enhance the Efficacy of Transarterial Embolization in a Rat Model of Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Wilkins, Luke R.; Brautigan, David L.; Wu, Hanping; Yarmohammadi, Hooman; Kubicka, Ewa; Serbulea, Vlad; Leitinger, Norbert; Liu, Wendy; Haaga, John R.

    2017-01-01

    IntroductionWe hypothesize that the combination of transarterial embolization (TAE) plus inhibition of lactate export will limit anaerobic metabolism and reduce tumor survival compared to TAE alone. The purpose of this study was to test this hypothesis in a rat model of hepatocellular carcinoma (HCC).MethodsRat N1-S1 hepatoma cells were assayed in vitro using the Seahorse XF analyzer to measure extracellular acidification (lactate excretion) comparing effects of the addition of caffeic acid (CA) or ferulic acid (FA) or UK-5099 with control. Monocarboxylate transporter Slc16a3 was knocked down by RNAi. N1S1 tumors were orthotopically implanted in rats and 4 groups evaluated: (1) Control, (2) TAE-only, (3) TAE plus CA, and (4) TAE plus FA. Tumor size was determined by ultrasound and analyzed by repeated measures statistics. Tumors harvested at 4 weeks were examined by microscopy.ResultsSeahorse assays showed that CA and FA caused a significant reduction by >90% in lactate efflux by N1S1 tumor cells (p < 0.01). Knockdown of Slc16a3 prevented inhibition by CA. In vivo tumors grew 30-fold in volume over 4 weeks in untreated controls. By comparison, TAE resulted in near cessation of growth (10% in 4-week time period). However, both TAE + CA and TAE + FA caused a significant reduction of tumor volumes (87 and 72%, respectively) compared to control and TAE (p < 0.05). Pathologic evaluation revealed residual tumor in the TAE group but no residual viable tumor cells in the TAE + CA and TAE + FA groups.ConclusionAddition of CA or FA enhances the effectiveness of TAE therapy for HCC in part by blocking lactate efflux.

  8. Stereotactic body radiation therapy with or without transarterial chemoembolization for patients with primary hepatocellular carcinoma: preliminary analysis

    Directory of Open Access Journals (Sweden)

    Yoon Seung

    2008-11-01

    Full Text Available Abstract Background The objectives of this retrospective study was to evaluate the efficacy of stereotactic body radiation therapy (SBRT for small non-resectable hepatocellular carcinoma (HCC and SBRT combined with transarterial chemoembolization (TACE for advanced HCC with portal vein tumor thrombosis (PVTT. Methods Thirty one patients with HCC who were treated with SBRT were used for the study. We studied 32 HCC lesions, where 23 lesions (22 patients were treated targeting small non-resectable primary HCC, and 9 lesions (9 patients targeting PVTT using the Cyberknife. All the 9 patients targeting PVTT received TACE for the advanced HCC. Tumor volume was 3.6–57.3 cc (median, 25.2 cc and SBRT dose was 30–39 Gy (median, 36 Gy in 3 fractions for consecutive days for 70–85% of the planned target volume. Results The median follow up was 10.5 months. The overall response rate was 71.9% [small HCC: 82.6% (19/23, advanced HCC with PVTT: 44.4% (4/9], with the complete and partial response rates of 31.3% [small HCC: 26.1% (6/23, advanced HCC with PVTT: 11.1% (1/9], and 50.0% [small HCC: 56.5% (13/23, advanced HCC with PVTT: 33.3% (3/9], respectively. The median survival period of small HCC and advanced HCC with PVTT patients was 12 months and 8 months, respectively. No patient experienced Grade 4 toxicity. Conclusion SBRT for small HCC and SBRT combined with TACE for advanced HCC with PVTT showed feasible treatment modalities with minimal side effects in selected patients with primary HCC.

  9. Preemptive antiviral therapy with entecavir can reduce acute deterioration of hepatic function following transarterial chemoembolization

    Directory of Open Access Journals (Sweden)

    Sun Hong Yoo

    2016-12-01

    Full Text Available Background/Aims Hepatic damage during transarterial chemoembolization (TACE is a critical complication in patients with hepatitis B virus (HBV-related hepatocellular carcinoma (HCC. Apart from its role in preventing HBV reactivation, there is some evidence for the benefits of preemptive antiviral therapy in TACE. This study evaluated the effect of preemptive antiviral therapy on acute hepatic deterioration following TACE. Methods This retrospective observational study included a prospectively collected cohort of 108 patients with HBV-related HCC who underwent TACE between January 2007 and January 2013. Acute hepatic deterioration following TACE was evaluated. Treatment-related hepatic decompensation was defined as newly developed encephalopathy, ascites, variceal bleeding, elevation of the bilirubin level, prolongation of prothrombin time, or elevation of the Child-Pugh score by ≥2 within 2 weeks following TACE. Univariate and multivariate analyses were conducted to identify factors influencing treatment-related decompensation. Preemptive antiviral therapy involves directing prophylaxis only toward high-risk chronic hepatitis B patients in an attempt to prevent the progression of liver disease. We regarded at least 6 months as a significant duration of preemptive antiviral treatment before diagnosis of HCC. Results Of the 108 patients, 30 (27.8% patients received preemptive antiviral therapy. Treatment-related decompensation was observed in 25 (23.1% patients during the follow-up period. Treatment-related decompensation following TACE was observed more frequently in the nonpreemptive group than in the preemptive group (29.5% vs. 6.7%, P=0.008. In the multivariate analysis, higher serum total bilirubin (Hazard ratio [HR] =3.425, P=0.013, hypoalbuminemia (HR=3.990, P=0.015, and absence of antiviral therapy (HR=7.597, P=0.006 were significantly associated with treatment-related hepatic decompensation. Conclusions Our findings suggest that

  10. Experimental study on the viscosity and adhesive performance of exogenous liquid fibrin glue.

    Science.gov (United States)

    Hayashi, Takuro; Hasegawa, Mitsuhiro; Inamasu, Joji; Adachi, Kazuhide; Nagahisa, Shinya; Hirose, Yuichi

    2014-01-01

    Exogenous fibrin glue (FG) is highly suitable for neurosurgical procedures, because of its viscosity and adhesive properties. Several FGs are commercially available, but only few reports detail their differences. In the present study, we investigated the viscosity and adhesive performance of two types of FG: one is derived from blood donated in Europe and the United States (CSL Behring's Beriplast(®), BP) and the other is derived from blood donated in Japan (the Chemo-Sero-Therapeutic Research Institute's Bolheal(®), BH). The viscosity test that measured fibrinogen viscosity revealed that BP had significantly higher viscosity than BH. Similarly, the dripping test showed that BP traveled a significantly shorter drip distance in the vertical direction than BH, although the transverse diameter of the coagulated FG did not differ statistically significantly. In the tensile strength test, BP showed superior adhesion performance over BH. The histological study of the hematoxylin-eosin-stained specimens in both groups showed favorable adhesion. Although further studies are required on its manufacturing and usage methods, FG shows differences in viscosity and adhesive performance according to the blood from which it is derived. We conclude that it is desirable to select the type and usage method of FG according to the characteristics of the surgical operation in question. Our findings suggest that FG produced from the blood donated in Europe and the United States might be more suitable for use in surgical procedures that demand an especially high degree of viscosity and rapid adhesive performance.

  11. Transarterial chemoembolization using gelatin sponges or microspheres plus lipiodol-doxorubicin versus doxorubicin-loaded beads for the treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Liu, Yi Sheng; Ou, Ming Ching; Tsai, Yi Shan; Lin, Xi Zhang; Wang, Chien Kuo; Tsai, Hong Ming; Chuang, Ming Tsung

    2015-01-01

    To retrospectively compare treatment of hepatocellular carcinoma (HCC) with transarterial chemoembolization (TACE) using gelatin sponges or microspheres plus lipiodol-doxorubicin vs. doxorubicin-loaded drug-eluting beads (DEB). A total of 158 patients with HCC received TACE from November 2010 to November 2011 were enrolled in this study, including 64 (40.5%) received TACE with lipiodol-doxorubicin and gelatin sponges (group A), 41 (25.9%) received TACE with lipiodol-doxorubicin and microspheres (group B), and 53 (33.5%) received TACE with doxorubicin-loaded DEB (group C). Tumor response and adverse events (AEs) were evaluated. No significant difference was found at baseline among the three groups. The doxorubicin dosage in group C was significantly (p < 0.001) higher compared to the dose used in groups A or B (median, 50 mg vs. 31 mg or 25 mg). Significantly (p < 0.001) more patients in group C achieved complete response compared to those in groups A or B (32.1% vs. 6.3% or 2.4%). Significantly (p < 0.001) less patients in group C had progressive disease compared to those in groups A or B (34.0% vs. 57.8% or 68.3%). Minor AEs were more common in groups A and B compared to group C, with rates of 54.7%, 34.1%, and 5.7%, respectively. In patients with HCC, TACE with DEB offers better safety and efficacy profiles compared to either TACE with gelatin sponges or TACE with microspheres.

  12. Utilização de adesivo de fibrina em cirurgias oftalmológicas Use of fibrin glue in ocular surgery

    Directory of Open Access Journals (Sweden)

    Melissa Manfroi Dal Pizzol

    2009-06-01

    Full Text Available OBJETIVO: Avaliar as diferentes técnicas cirúrgicas oftalmológicas nas quais se pode utilizar a cola biológica e possíveis complicações relacionadas ao seu uso. MÉTODOS: Estudo de série de casos retrospectivo, não-comparativo. Foram avaliados 161 olhos de pacientes com idade média de 51,8 anos em que foi utilizada cola biológica (Beriplast P® - Aventis Behring, Alemanha para fixação de tecido ou fechamento incisional. RESULTADOS: Foram avaliados 76 pacientes com pterígio, 4 com ceratoconjuntivite límbica superior, 4 com tumor limbar, 21 com conjuntivocálase, 31 com ceratopatia bolhosa, 7 com deficiência límbica, 6 com queimadura alcalina, 2 com Stevens-Johnson, 5 com catarata e 5 com glaucoma. Complicações foram relatas em 28 casos (17,4%. Descolamento do tecido fixado e granuloma foram as complicações mais frequentes. Descolamento ocorreu em 10 casos (5,6% (7 em transplante de membrana amniótica em ceratopatia bolhosa, 2 em transplante de conjuntiva autólogo após exérese de pterígio, 1 após transplante de limbo autólogo por Stevens-Johnson. Granuloma ocorreu em 9 casos (5,6% (5 em pacientes com queimadura alcalina aguda tratados com transplante de membrana amniótica, 1 em paciente com sequela de queimadura tratado com transplante de limbo autólogo e 3 em pacientes após exérese de pterígio tratados com transplante de conjuntiva autólogo. Todas as complicações ocorreram dentro da primeira semana de pós-operatório. CONCLUSÃO: Embora o presente seja retrospectivo e não-comparativo, podemos observar que a utilização do adesivo de fibrina parece ser segura e efetiva, além de apresentar baixas taxas de complicações nas cirurgias de superfície ocular e de segmento anterior.PURPOSE: To evaluate the use of fibrin glue and its complications in different ophthalmic surgeries. METHODS: A retrospective and non-comparative case series study. 161 eyes were evaluated. The mean age was 51.8 years. Fibrin glue

  13. Spontaneous Intramuscular Hematomas of the Abdomen and Pelvis: A New Multilevel Algorithm to Direct Transarterial Embolization and Patient Management

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Milen [Lausanne University Hospital, Department of Medicine (Switzerland); Sotiriadis, Charalampos; Gay, Frederique; Jouannic, Anne-Marie; Lachenal, Yann; Hajdu, Steven D.; Doenz, Francesco; Qanadli, Salah D., E-mail: salah.qanadli@chuv.ch [Lausanne University Hospital, Cardio-Thoracic and Vascular Unit, Department of Radiology (Switzerland)

    2017-04-15

    PurposeTo report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH).Materials and MethodsFrom May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized as IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed.ResultsTwo patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III).ConclusionTAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE.Level of Evidence4.

  14. Transarterial chemoembolization in very early and early-stage hepatocellular carcinoma patients excluded from curative treatment: A prospective cohort study

    International Nuclear Information System (INIS)

    Bargellini, Irene; Sacco, Rodolfo; Bozzi, Elena; Bertini, Marco; Ginanni, Barbara; Romano, Antonio; Cicorelli, Antonio; Tumino, Emanuele; Federici, Graziana; Cioni, Roberto; Metrangolo, Salvatore; Bertoni, Michele; Bresci, Giampaolo; Parisi, Giuseppe; Altomare, Emanuele; Capria, Alfonso; Bartolozzi, Carlo

    2012-01-01

    Aim: To assess clinical outcome of transarterial chemoembolization (TACE) in a series of patients with early-stage hepatocellular carcinoma (HCC), within Milan criteria, but clinically unfit for liver transplantation (OLT). Methods: From January 2006 to May 2009, 67 patients (43 males, mean age 70 ± 7.6 years) with very early or early-stage unresectable HCC, within Milan selection criteria but clinically unfit for OLT, underwent TACE. The primary endpoint of the study was overall survival. Secondary endpoints were: safety, liver toxicity, 1-month tumour response according to the amended RECIST criteria, time to local and distant intrahepatic tumour recurrence and time to radiological progression. Results: Two major periprocedural complications occurred (3%), consisting of liver failure. Periprocedural mortality rate was 1.5% (1 patient). A significant increase in ALT and bilirubin levels 24 h after treatment was reported, with progressive decrease at discharge. At 1-month follow-up, complete and partial tumour response rates were 67.2% and 29.8%, respectively, with two cases of progressive disease. Mean follow-up was 37.3 ± 15 months. The 1-, 2-, and 3-year overall survival rates were 90.9%, 86.1%, and 80.5%, respectively. Median expected time to local tumour recurrence and intrahepatic tumour recurrence were 7.9 and 13.8 months, respectively. Radiological disease progression was observed in 12 patients (17.9%) with a mean expected time of 26.5 months. Conclusion: In patients with early-stage HCC, clinically excluded from OLT and unfit for surgery or percutaneous ablation, TACE is a safe and effective option, with favourable long-term survival.

  15. The ART score is not effective to select patients for transarterial chemoembolization retreatment in an Italian series.

    Science.gov (United States)

    Terzi, Eleonora; Terenzi, Laura; Venerandi, Laura; Croci, Luca; Renzulli, Matteo; Mosconi, Cristina; Allegretti, Giulia; Granito, Alessandro; Golfieri, Rita; Bolondi, Luigi; Piscaglia, Fabio

    2014-01-01

    The ART score (a point score for the assessment of retreatment with transarterial chemoembolization, TACE) has been recently developed in Austria to differentiate patients who may benefit from multiple sessions of TACE for hepatocellular carcinoma (HCC) treatment. The primary aim of the study was to test the validity of the ART score in an Italian study cohort. The secondary aims were to evaluate overall survival (OS) and clinical determinants of improved survival in patients treated with multiple TACE sessions. The ART score and the clinical outcome of 51 consecutive patients with HCC submitted to multiple TACE sessions from April 2002 to December 2009 were retrospectively analyzed. Median OS was 26.0 months (95% confidence interval 18.4-33.6) with 1-, 3- and 5-year survival rates of 75, 33 and 11%, respectively). Thirty-three patients had an ART score of 0-1.5 and in 18 it was ≥2.5, but in our patient series, the ART score was not found to be a predictor of survival (p = 0.173). At univariate analysis, tumor extent (uni- vs. bilobar: 34.0 vs. 9.0 months; p < 0.001), Child-Pugh score before the second TACE (A vs. B7 vs. B8-9: 26.0 vs. 16.0 vs. 5.0 months; p = 0.005) and Child-Pugh score increase between the first and second TACE (absent vs. + 1 point vs. + ≥2 points: 27.0 vs. 4.0 vs. 5.0 months; p < 0.001) were statistically related with survival. At multivariate analysis, only Child-Pugh score increase remained a significant predictor of worse survival (p = 0.001, hazard rate = 11.6). The ART score was not found to work as an objective tool to guide TACE retreatment in our Italian patient series, only the Child-Pugh score increase was an independent predictor of a shorter survival.

  16. Transarterial Chemoembolization for Hepatocellular Carcinoma with a New Generation of Beads: Clinical–Radiological Outcomes and Safety Profile

    Energy Technology Data Exchange (ETDEWEB)

    Spreafico, Carlo, E-mail: carlo.spreafico@istitutotumori.mi.it; Cascella, Tommaso, E-mail: tommaso.cascella@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Radiology (Italy); Facciorusso, Antonio, E-mail: antonio.facciorusso@istitutotumori.mi.it; Sposito, Carlo, E-mail: carlo.sposito@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Liver Surgery and Transplant (Italy); Rodolfo, Lanocita, E-mail: rodolfo.lanocita@istitutotumori.mi.it; Morosi, Carlo, E-mail: carlo.morosi@istitutotumori.mi.it; Civelli, Enrico M., E-mail: enrico.civelli@istitutotumori.mi.it; Vaiani, Marta, E-mail: marta.vaiani@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Radiology (Italy); Bhoori, Sherrie, E-mail: sherrie.bhoori@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Liver Surgery and Transplant (Italy); Pellegrinelli, Alessandro, E-mail: alessandro.pellegrinelli@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Pathology (Italy); Marchianò, Alfonso, E-mail: alfonso.marchiano@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Radiology (Italy); Mazzaferro, Vincenzo, E-mail: vincenzo.mazzaferro@istitutotumori.mi.it [Fondazione Istituto Tumori, Department of Liver Surgery and Transplant (Italy)

    2015-02-15

    PurposeTo evaluate the short-term safety and efficacy of the new generation of 70–150 µm drug-eluting beads (M1 DEB) in patients with hepatocellular carcinoma undergoing transarterial chemoembolization (TACE) as a primary therapy or as a bridge to liver transplantation (LT).MethodsForty-five consecutive patients underwent TACE with M1 DEB loaded with doxorubicin (DEBDOX/M1). Clinical data were recorded at 12, 24, and 48 h, 7 and 30 days after treatment. Response was assessed by computed tomographic scan according to the modified response evaluation criteria in solid tumors criteria, and a second DEBDOX/M1 TACE was scheduled within 6 weeks in case of a noncomplete response.ResultsAll patients had well-compensated cirrhosis (97.7 % Child A, 44.4 % hepatitis C virus, median age 61 years). Twenty patients (44.4 %) had Barcelona Clinic for Liver Cancer class B disease; the median number of nodules and their sum of diameters were 2 (range 1–6) and 43 mm (range 10–190), respectively. The mean number of TACE procedures per patient was 1.4. Objective response rate (complete + partial response) was 77.7 % with a median time to best response of 3 months (95 % confidence interval 2–4). In 13 patients, DEBDOX/M1 TACE served as a bridge/downstaging to LT/surgery. Pathology showed that more than 90 % necrosis was achieved in 10 of 28 nodules. DEBDOX/M1 TACE was well tolerated, and the grade 3/4 adverse event rate was low (1 of 65 procedures).ConclusionDEBDOX/M1 TACE is an effective procedure with a favorable safety profile and promising results in terms of objective response rate, tumor downstaging, and necrosis.

  17. Computed Tomographic-Guided Radiofrequency Ablation of Recurrent or Residual Hepatocellular Carcinomas around Retained Iodized Oil after Transarterial Chemoembolization

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Young Hwan [Center for Liver Cancer, National Cancer Center, Goyang 410-769 (Korea, Republic of); Department of Radiology, Research Institute and Hospital, National Cancer Center, Goyang 410-769 (Korea, Republic of); Choi, Joon-Il [Center for Liver Cancer, National Cancer Center, Goyang 410-769 (Korea, Republic of); Department of Radiology, Research Institute and Hospital, National Cancer Center, Goyang 410-769 (Korea, Republic of); Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Kim, Hyun Beom [Center for Liver Cancer, National Cancer Center, Goyang 410-769 (Korea, Republic of); Department of Radiology, Research Institute and Hospital, National Cancer Center, Goyang 410-769 (Korea, Republic of); Kim, Min Ju [Department of Radiology, Research Institute and Hospital, National Cancer Center, Goyang 410-769 (Korea, Republic of)

    2013-07-01

    To assess the clinical efficacy, safety, and risk factors influencing local tumor progression, following CT-guided radiofrequency ablation (RFA) of recurrent or residual hepatocellular carcinoma (HCC), around iodized oil retention. Sixty-four patients (M : F = 51 : 13, 65.0 ± 8.2 years old) with recurrent or residual HCC (75 index tumors, size = 14.0 ± 4.6 mm) had been treated by CT-guided RFA, using retained iodized oil as markers for targeting. The technical success, technique effectiveness rate and complications of RFA were then assessed. On pre-ablative and immediate follow-up CT after RFA, we evaluated the size of enhancing index tumors and iodized oil retention, presence of abutting vessels, completeness of ablation of iodized oil retention, and the presence of ablative margins greater than 5 mm. Also, the time interval between transarterial chemoembolization and RFA was assessed. The cumulative local tumor progression rate was calculated using the Kaplan-Meier method, and the Cox proportional hazards model was adopted, to clarify the independent factors affecting local tumor progression. The technical success and technique effectiveness rate was 100% and 98.7%, respectively. Major complications were observed in 5.6%. The cumulative rates of local tumor progression at 1 and 2 years were 17.5% and 37.5%, respectively. In multivariate analyses, partial ablation of the targeted iodized oil retention was the sole independent predictor of a higher local tumor progression rate. CT-guided RFA of HCC around iodized oil retention was effective and safe. Local tumor progression can be minimized by complete ablation of not only index tumors, but targeted iodized oil deposits as well.

  18. Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus 90Y-radioembolization for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Ludwig, Johannes M.; Xing, Minzhi; Zhang, Di; Kim, Hyun S.

    2017-01-01

    To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 ( 90 Y)-radioembolization for hepatocellular carcinoma (HCC). Studies comparing conventional (c)TACE versus 90 Y-radioembolization or DEB-TACE for HCC treatment were identified using PubMed/Medline, Embase, and Cochrane databases. The adjusted indirect meta-analytic method for effectiveness comparison of DEB-TACE versus 90 Y-radioembolization was used. Wilcoxon rank-sum test was used to compare baseline characteristics. A priori defined sensitivity analysis of stratified study subgroups was performed for primary outcome analyses. Publication bias was tested by Egger's and Begg's tests. Fourteen studies comparing DEB-TACE or 90 Y-radioembolization with cTACE were included. Analysis revealed a 1-year overall survival benefit for DEB-TACE over 90 Y-radioembolization (79 % vs. 54.8 %; OR: 0.57; 95 %CI: 0.355-0.915; p = 0.02; I-squared: 0 %; p > 0.5), but not for the 2-year (61 % vs. 34 %; OR: 0.65; 95%CI: 0.294-1.437; p = 0.29) and 3-year survival (56.4 % vs. 20.9 %; OR: 0.713; 95 % CI: 0.21-2.548; p = 0.62). There was significant heterogeneity in the 2- and 3-year survival analyses. The pooled median overall survival was longer for DEB-TACE (22.6 vs. 14.7 months). There was no significant difference in tumour response rate. DEB-TACE and 90 Y-radioembolization are efficacious treatments for patients suffering from HCC; DEB-TACE demonstrated survival benefit at 1-year compared to 90 Y-radioembolization but direct comparison is warranted for further evaluation. (orig.)

  19. Safety and efficacy of transarterial chemoembolization plus sorafenib for hepatocellular carcinoma with portal venous tumour thrombus

    International Nuclear Information System (INIS)

    Pan, T.; Li, X.-S.; Xie, Q.-K.; Wang, J.-P.; Li, W.; Wu, P.-H.; Zhao, M.

    2014-01-01

    Aim: To evaluate the safety and efficacy of combined therapy with transarterial chemoembolization (TACE) and sorafenib for hepatocellular carcinoma (HCC) with portal venous tumour thrombus (PVTT). Materials and methods: This study was approved by the institutional review board. From May 2009 to May 2012, 170 consecutive patients were newly diagnosed with advanced-stage HCC and treated with TACE plus sorafenib. Among them, 41 patients with PVTT were retrospectively enrolled in the study. The adverse events (AEs), overall survival (OS), time to progression (TTP), and prognostic factors were analysed. Statistical analysis was performed with the Kaplan–Meier method using the log-rank test and Cox regression models. Results: The most common AEs were hand–foot skin reaction related to sorafenib and fever related to TACE. Procedure-related mortality and grade 4 AEs were not observed. Grade 3 AEs were observed in five patients. During the median follow-up period of 13.5 months (range 1.4–45 months), the 6-month and 1-year survival rates were 87.7% and 53.6%, respectively. The median OS was 13 months (range 1.4–44.8 months), and the median TTP was 7 months (range 1–18.6 months). The Child–Pugh class (p = 0.022), extrahepatic metastasis (p = 0.009), and gross morphological type (nodular type versus diffuse type; p = 0.008) were prognostic factors related to OS in the multivariate analysis. Conclusion: TACE plus sorafenib in an interrupted therapeutic scheme was well tolerated and might improve OS for HCC patients with PVTT, especially in those with Child–Pugh class A, no extrahepatic metastasis, or nodular-type HCC. - Highlights: • We introduce the safety of TACE plus sorafenib for patients with advanced HCC and PVTT. • We suggest that the combined therapy might prolong the TTP and OS than sorafenib alone. • Clinic benefit determinations with the Child-Pugh class, extrahepatic metastasis or gross type

  20. Thromboembolic events associated with single balloon-, double balloon-, and stent-assisted coil embolization of asymptomatic unruptured cerebral aneurysms: evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Takigawa, Tomoji; Suzuki, Kensuke; Sugiura, Yoshiki; Suzuki, Ryotaro; Takano, Issei; Shimizu, Nobuyuki; Tanaka, Yoshihiro; Hyodo, Akio

    2014-01-01

    The introduction of the balloon remodeling and stent-assisted technique has revolutionized the approach to coil embolization for wide-neck aneurysms. The purpose of this study was to determine the frequency of thromboembolic events associated with single balloon-assisted, double balloon-assisted, and stent-assisted coil embolization for asymptomatic unruptured aneurysms. A retrospective review was undertaken by 119 patients undergoing coiling with an adjunctive technique for unruptured saccular aneurysms (64 single balloon, 12 double balloon, 43 stent assisted). All underwent diffusion-weighted imaging (DWI) within 24 h after the procedure. DWI showed hyperintense lesions in 48 (40 %) patients, and ten (21 %) of these patients incurred neurological deterioration (permanent, two; transient, eight). Hyperintense lesions were detected significantly more often in procedures with the double balloon-assisted technique (7/12, 58 %) than with the single balloon-assisted technique (16/64, 25 %, p = 0.05). Occurrence of new lesions was significantly higher with the use of stent-assisted technique (25/43, 58 %) than with the single balloon-assisted technique (p = 0.001). Symptomatic ischemic rates were similar between the three groups. The increased number of microcatheters was significantly related to the DWI abnormalities (two microcatheters, 15/63 (23.8 %); three microcatheters, 20/41 (48.8 %) (p = 0.008); four microcatheters, 12/15 (80 %) (p = 0.001)). Thromboembolic events detected on DWI related to coil embolization for unruptured aneurysms are relatively common, especially in association with the double balloon-assisted and stent-assisted techniques. Furthermore, the number of microcatheters is highly correlated with DWI abnormalities. The high rate of thromboembolic events suggests the need for evaluation of platelet reactivity and the addition or change of antiplatelet agents. (orig.)

  1. Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus {sup 90}Y-radioembolization for hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Johannes M.; Xing, Minzhi [Yale School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Zhang, Di [University of Pittsburgh Graduate School of Public Health, Department of Biostatistics, Pittsburgh, PA (United States); Kim, Hyun S. [Yale School of Medicine, Division of Interventional Radiology, Department of Radiology and Biomedical Imaging, New Haven, CT (United States); Yale School of Medicine, Yale Cancer Center, New Haven, CT (United States)

    2017-05-15

    To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 ({sup 90}Y)-radioembolization for hepatocellular carcinoma (HCC). Studies comparing conventional (c)TACE versus {sup 90}Y-radioembolization or DEB-TACE for HCC treatment were identified using PubMed/Medline, Embase, and Cochrane databases. The adjusted indirect meta-analytic method for effectiveness comparison of DEB-TACE versus {sup 90}Y-radioembolization was used. Wilcoxon rank-sum test was used to compare baseline characteristics. A priori defined sensitivity analysis of stratified study subgroups was performed for primary outcome analyses. Publication bias was tested by Egger's and Begg's tests. Fourteen studies comparing DEB-TACE or {sup 90}Y-radioembolization with cTACE were included. Analysis revealed a 1-year overall survival benefit for DEB-TACE over {sup 90}Y-radioembolization (79 % vs. 54.8 %; OR: 0.57; 95 %CI: 0.355-0.915; p = 0.02; I-squared: 0 %; p > 0.5), but not for the 2-year (61 % vs. 34 %; OR: 0.65; 95%CI: 0.294-1.437; p = 0.29) and 3-year survival (56.4 % vs. 20.9 %; OR: 0.713; 95 % CI: 0.21-2.548; p = 0.62). There was significant heterogeneity in the 2- and 3-year survival analyses. The pooled median overall survival was longer for DEB-TACE (22.6 vs. 14.7 months). There was no significant difference in tumour response rate. DEB-TACE and {sup 90}Y-radioembolization are efficacious treatments for patients suffering from HCC; DEB-TACE demonstrated survival benefit at 1-year compared to {sup 90}Y-radioembolization but direct comparison is warranted for further evaluation. (orig.)

  2. Combination of Transarterial Chemoembolization and Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma With Inferior Vena Cava Tumor Thrombus

    International Nuclear Information System (INIS)

    Koo, Ja Eun; Kim, Jong Hoon; Lim, Young-Suk

    2010-01-01

    Purpose: To evaluate the effects of transarterial chemoembolization (TACE) and three-dimensional conformal radiotherapy (CRT) in patients with hepatocellular carcinoma (HCC) and inferior vena cava tumor thrombus (IVCTT). Methods and Materials: A total of 42 consecutive patients who underwent TACE and CRT (TACE+CRT group) for the treatment of HCC with IVCTT were prospectively enrolled from July 2004 to October 2006. As historical controls, 29 HCC patients with IVCTT who received TACE alone (TACE group) between July 2003 and June 2004 were included. CRT was designed to target only the IVCTT and to deliver a median total dose of 45 Gy (range, 28-50 Gy). Results: Most baseline characteristics of the two groups were similar (p > 0.05). The response and progression-free rates of IVCTT were significantly higher in the TACE+CRT group than in the TACE group (42.9% and 71.4% vs. 13.8% and 37.9%, respectively; p < 0.01 for both rates). Overall, patient survival was significantly higher in the TACE+CRT group than in the TACE group (p < 0.01), with a median survival time of 11.7 months and 4.7 months, respectively. Treatment with TACE+CRT (hazard ratio [HR] = 0.38; 95% confidence interval [CI], 0.20-0.71), progression of IVCTT (HR = 4.05; 95% CI, 2.00-8.21), Child-Pugh class B (HR = 3.44; 95% CI, 1.79-6.61), and portal vein invasion (HR = 2.31; 95% CI, 1.19-4.50) were identified as independent predictors of mortality by multivariable analysis. Conclusions: The combination of TACE and CRT is more effective in the control of IVCTT associated with HCC and improves patient survival compared with TACE alone.

  3. EFFECTS OF PRESS PRESSURE ON GLUE LINE THICKNESS AND PROPERTIES OF LAMINATED VENEER LUMBER GLUED WITH MELAMINE UREA FORMALDEHYDE ADHESIVE

    Directory of Open Access Journals (Sweden)

    Ramazan Kurt,

    2012-07-01

    Full Text Available Laminated veneer lumbers (LVLs were manufactured from half-round sliced I-214 hybrid poplar clone veneers with MUF adhesives using press pressures ranging from 2.5 to 15 kg cm-2. The results showed that the press pressures affected the glue line thickness (GLT and the physical and mechanical properties of the LVLs. Higher specific gravity (SG and mechanical properties, but lower GLT were developed as a result of using higher press pressures. The optimum press pressure was found to be 10 kg cm-2 in relation to GLT, SG, and mechanical properties. Significant linear correlations were found between GLT and mechanical properties. GLT can be used to determine the quality of wood bonding and may become a valuable tool for this purpose. Reliable data on the optimum GLT and press pressures can be used to design safe wood bonding applications in all aspects of wood based composites, as well as wood constructions when appropriate techniques are adopted to measure the GLT.

  4. Combined transarterial chemoembolization of the right inferior phrenic artery and radiofrequency ablation for small hepatocellular carcinoma near the diaphragm: its efficacy and safety.

    Science.gov (United States)

    Hyun, Dongho; Cho, Sung Ki; Shin, Sung Wook; Park, Kwang Bo; Lee, Sang Yub; Park, Hong Suk; Choo, Sung Wook; Do, Young Soo

    2018-02-28

    The purpose of the study is to report the efficacy and safety of combined transarterial chemoembolization (TACE) of the right inferior phrenic artery (IPA) and radiofrequency ablation (RFA) for small hepatocellular carcinoma (HCC) near the diaphragm supplied by the right IPA. From July 2009 through April 2015, 11 patients with small (≤ 3 cm) HCC near the diaphragm, which was infeasible for ultrasound-guided RFA and supplied by the right IPA, received TACE of the right IPA and subsequent RFA in one session. The safety and therapeutic efficacy, including technique effectiveness and local tumor progression (LTP), were evaluated. Technique effectiveness was achieved in all the 11 patients (100%). During average follow-up period of 39.2 months (range 13-89 months), LTP occurred in none of the 11 patients. There were twelve minor complications in eight patients, including right shoulder pain (n = 4), right pleural effusion (n = 2), diaphragmatic thickening (n = 2), transient lung change (n = 2), subsegmental intrahepatic bile duct stricture (n = 1), and subsegmental hepatic infarction (n = 1). No major complications were encountered CONCLUSION: Combined TACE of the right IPA and RFA can be a safe and effective treatment for small HCC near the diaphragm that is supplied by the right IPA.

  5. Retrospective comparison of surgical ligation and transarterial catheter occlusion for treatment of patent ductus arteriosus in two hundred and four dogs (1993-2003).

    Science.gov (United States)

    Goodrich, Kimberly R; Kyles, Andrew E; Kass, Phillip H; Campbell, Fiona

    2007-01-01

    To compare procedure time, complications, mortality, and short-term outcome in dogs with patent ductus arteriosus (PDA) treated by surgical ligation (SL) or transarterial coil occlusion (TCO). Retrospective study. Dogs with PDA (n=204). Medical records of dogs treated for PDA were reviewed. Dogs treated by SL when it was the primary method used for PDA treatment (1993-1998) were compared with dogs treated by TCO when it was the primary method used for PDA treatment (1999-2003). Dogs treated during the transition between techniques, dogs treated with SL (1999-2003) and dogs treated with TCO before 1999, as well as dogs with pulmonary hypertension, or bidirectional or reversed (right-to-left) flow through the PDA were excluded from analysis. Age, weight, gender distribution, and procedure times (P=.43) were similar for both groups. Major complications were more common with SL (12% versus 4.3%; P=.035) whereas minor complications were more common with TCO (12% versus 26%; P=.015). Initial success rate was higher for SL (94%) compared with TCO (84%; P=.027). There was no significant difference in mortality between SL (5.6%) and TCO (2.6%; P=.27). Both SL and TCO are acceptable PDA treatments with comparable mortality; however, SL was associated with a higher risk of major complications and TCO was associated with a lower initial success rate.

  6. The mechanical and biological studies of calcium phosphate cement-fibrin glue for bone reconstruction of rabbit femoral defects

    Directory of Open Access Journals (Sweden)

    Dong J

    2013-03-01

    Full Text Available Jingjing Dong,1,* Geng Cui,2,* Long Bi,1,* Jie Li,3 Wei Lei11Institute of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi’an, Shaanxi, People’s Republic of China; 2Institute of Orthopedics, General Hospital of PLA, Beijing, People’s Republic of China; 3Institute of Gynecology and Obstetrics, General Hospital of PLA, Beijing, People’s Republic of China*These authors contributed equally to this workAbstract: In order to improve the mechanical and biological properties of calcium phosphate cement (CPC, nanometer-biomaterial for bone reconstruction in the rabbit femoral defect model, fibrin glue (FG, the natural product, purified from the blood was introduced at three different ratios. The CPC powder and the FG solution were mixed, respectively, at the powder/liquid (P/L ratios (g/mL of 1:1, 3:1, and 5:1 (g/mL, and pure CPC was used as a control. After being implanted into the femoral defect in rabbit, the healing process was evaluated by micro-computed tomography scan, biomechanical testing, and histological examination. By micro-computed tomography analysis, the P/L ratio of 1:1 (g/mL group indicated the largest quantity of new bone formation at 4 weeks, 8 weeks, and 12 weeks after implantation, respectively. Bone volume per trabecular volume of the 1:1 group was highest in the four groups, which was 1.45% ± 0.42%, 7.35% ± 1.45%, and 29.10% ± 1.67% at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the biomechanical tests, the compressive strength and the elastic modulus of the three CPC–FG groups were much higher than those of the pure CPC group at the determined time point (P < 0.05. The histological evaluation also showed the best osseointegration in the 1:1 group at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the 1:1 group, the bone grew into the pore of the cement in the laminar arrangement and connected with the cement tightly at the 12th week after the operation

  7. Dosimetry of 131I labeled metuximab and transarterial chemoembolization for treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Ma Jun; Wang Jianhua; Liu Rong; Qian Sheng; Chen Yi; Shi Hongcheng; Gu Yusen

    2009-01-01

    Objective: Metuximab is a specific monoclonal antibody F(ab') fragment targeted to the hepatocellular carcinoma (HCC) associated antigen of HAb18G/CD147. 131 I labeled metuximab has shown to be effective response on HCC in phase I/II trails. To evaluate the feasibility of 131 I-metuximab combined with transarterial chemoembolization (TACE) is the treatment of HCC, the authors estimated the radiation absorbed dose to organs. Methods: 131 I-metuximab (27.75 MBq/kg) and the mixture of anticancer drug and Lipiodol with interval 20 min later were administered to 21 patients with HCC via a transfemoral catheter. The pharmacokinetic and dosimetric data were collected by means of venous blood samples, urine collections, and 4 or 5 γ-scintigraphies (SPECT) over 7 d. The total amount of activity in percent of injected activity (% ID) of main organ and the total body were calculated by regions of interest (ROI). The cumulated activities were determined from integration of the time-% ID curves using the SPSS 12.0 software. Absorbed doses to organ and red marrow were estimated according to the medical internal radiation dose (MIRD) formalism and blood-based marrow estimation with a red marrow-to-blood activity concentration ratio. The tumor- to-no tumor ratio was calculated as well. Results: A mean administered activity was 1.89 GBq per session (range 1.47-2.23 GBq). SPECT scans showed the significant accumulation of the radioconjugate in liver tumor and faint uptake in other organs until 14 d. Organ absorbed dose (n=12): the total absorbed dose to liver, spleen, thyroid, lungs, kidney and total-body was (3.19 ± 1.01), (3.65 ± 2.41), (3.61 ± 2.40), (0.97 ± 0.23), (0.96 ± 0.35) and (0.57 ± 1.55) Gy, with (0.55 ± 0.09) Gy to the red marrow (n=7), respectively. From 2.88 ± 1.11 to 1.64 ± 0.39 were observed in tumor-to-liver ratio at 3 h to 168 h. Conclusion: Internal absorbed dose estimation based on MIRD formalism is not only to establish re- liable dose

  8. Effect of transarterial chemoembolization with miriplatin plus epirubicin on local control of hepatocellular carcinoma: a retrospective comparison with miriplatin monotherapy

    Directory of Open Access Journals (Sweden)

    Hashimoto N

    2013-08-01

    Full Text Available Naoko Hashimoto,1 Jin Iwazawa,1 Shoichi Ohue,2 Takashi Mitani11Department of Radiology, Nissay Hospital, Nishiku, Osaka, Japan; 2Department of Radiology, Komatsu Hospital, Neyagawa, JapanObjective: We aimed to evaluate local tumor control after transarterial chemoembolization (TACE for hepatocellular carcinoma using miriplatin and low-dose epirubicin combination therapy.Methods: We retrospectively analyzed the records of patients who underwent TACE using miriplatin plus low-dose epirubicin (30 patients, 61 nodules, August 2011–March 2012 and control patients who underwent TACE using miriplatin alone (36 patients, 70 nodules, June 2010–July 2011. The local control rate was compared between the two groups using the Kaplan–Meier estimator and the log-rank test. Factors affecting local tumor recurrence were analyzed using multivariate logistic regression analysis. Treatment-related toxicity was evaluated using the Common Terminology Criteria for Adverse Events.Results: The local control rates at 6 months and 1 year were 87% and 65% for the miriplatin plus low-dose epirubicin group, and 61% and 43% for the miriplatin group, respectively. Local tumor control rates were significantly better in the miriplatin plus low-dose epirubicin group than in the miriplatin group (P = 0.038. Multivariate analysis showed that the addition of epirubicin was an independent factor associated with better local tumor control (hazard ratio 0.2, P = 0.001. Overall incidence rates for adverse events were not significantly different between the two groups.Conclusion: Additional usage of low-dose epirubicin for TACE using miriplatin improved local tumor control of hepatocellular carcinoma with adverse effects comparable to those observed with TACE using miriplatin alone.Keywords: combination therapy, local recurrence, liver, embolization, comparative study

  9. Towards real-time cardiovascular magnetic resonance-guided transarterial aortic valve implantation: In vitro evaluation and modification of existing devices

    Directory of Open Access Journals (Sweden)

    Ladd Mark E

    2010-10-01

    Full Text Available Abstract Background Cardiovascular magnetic resonance (CMR is considered an attractive alternative for guiding transarterial aortic valve implantation (TAVI featuring unlimited scan plane orientation and unsurpassed soft-tissue contrast with simultaneous device visualization. We sought to evaluate the CMR characteristics of both currently commercially available transcatheter heart valves (Edwards SAPIEN™, Medtronic CoreValve® including their dedicated delivery devices and of a custom-built, CMR-compatible delivery device for the Medtronic CoreValve® prosthesis as an initial step towards real-time CMR-guided TAVI. Methods The devices were systematically examined in phantom models on a 1.5-Tesla scanner using high-resolution T1-weighted 3D FLASH, real-time TrueFISP and flow-sensitive phase-contrast sequences. Images were analyzed for device visualization quality, device-related susceptibility artifacts, and radiofrequency signal shielding. Results CMR revealed major susceptibility artifacts for the two commercial delivery devices caused by considerable metal braiding and precluding in vivo application. The stainless steel-based Edwards SAPIEN™ prosthesis was also regarded not suitable for CMR-guided TAVI due to susceptibility artifacts exceeding the valve's dimensions and hindering an exact placement. In contrast, the nitinol-based Medtronic CoreValve® prosthesis was excellently visualized with delineation even of small details and, thus, regarded suitable for CMR-guided TAVI, particularly since reengineering of its delivery device toward CMR-compatibility resulted in artifact elimination and excellent visualization during catheter movement and valve deployment on real-time TrueFISP imaging. Reliable flow measurements could be performed for both stent-valves after deployment using phase-contrast sequences. Conclusions The present study shows that the Medtronic CoreValve® prosthesis is potentially suited for real-time CMR-guided placement

  10. Treatment algorithm based on the multivariate survival analyses in patients with advanced hepatocellular carcinoma treated with trans-arterial chemoembolization.

    Directory of Open Access Journals (Sweden)

    Hasmukh J Prajapati

    Full Text Available To develop the treatment algorithm from multivariate survival analyses (MVA in patients with Barcelona clinic liver cancer (BCLC C (advanced Hepatocellular carcinoma (HCC patients treated with Trans-arterial Chemoembolization (TACE.Consecutive unresectable and non-tranplantable patients with advanced HCC, who received DEB TACE were studied. A total of 238 patients (mean age, 62.4yrs was included in the study. Survivals were analyzed according to different parameters from the time of the 1st DEB TACE. Kaplan Meier and Cox Proportional Hazard model were used for survival analysis. The SS was constructed from MVA and named BCLC C HCC Prognostic (BCHP staging system (SS.Overall median survival (OS was 16.2 months. In HCC patients with venous thrombosis (VT of large vein [main portal vein (PV, right or left PV, hepatic vein, inferior vena cava] (22.7% versus small vein (segmental/subsegmental PV (9.7% versus no VT had OSs of 6.4 months versus 20 months versus 22.8 months respectively (p<0.001. On MVA, the significant independent prognostic factors (PFs of survival were CP class, eastern cooperative oncology group (ECOG performance status (PS, single HCC<5 cm, site of VT, metastases, serum creatinine and serum alpha-feto protein. Based on these PFs, the BCHP staging system was constructed. The OSs of stages I, II and III were 28.4 months, 11.8 months and 2.4 months accordingly (p<0.001. The treatment plan was proposed according to the different stages.On MVA of patients with advanced HCC treated with TACE, significant independent prognostic factors (PFs of survival were CP class, ECOG PS, single HCC<5 cm or others, site of VT, metastases, serum creatinine and serum alpha-feto protein. New BCHP SS was proposed based on MVA data to identify the suitable advanced HCC patients for TACE treatments.

  11. Histogram Analysis of CT Perfusion of Hepatocellular Carcinoma for Predicting Response to Transarterial Radioembolization: Value of Tumor Heterogeneity Assessment.

    Science.gov (United States)

    Reiner, Caecilia S; Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz; Schaefer, Niklaus; Veit-Haibach, Patrick; Pfammatter, Thomas; Alkadhi, Hatem

    2016-03-01

    To evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE). Sixteen patients (15 male; mean age 65 years; age range 47-80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters' ability to discriminate responders from non-responders. According to mRECIST, 8 patients (50%) were responders and 8 (50%) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min(-1) 100 mL(-1)); p 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min(-1) 100 mL(-1), therapy response could be predicted with a sensitivity of 88% (7/8) and specificity of 75% (6/8). Voxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.

  12. Endoscopic debridement and fibrin glue injection of a chronic Morel-Lavallée lesion of the knee in a professional soccer player: A case report and literature review.

    Science.gov (United States)

    Koc, Baris B; Somorjai, Nicolaas; P M Kiesouw, Egid; Vanderdood, Kurt; Meesters-Caberg, Marleen; Draijer, Frits W; Jansen, Edwin J P

    2017-01-01

    A Morel-Lavallée lesion is a post-traumatic closed degloving injury of soft tissue. The lesion is due to a shearing trauma with separation of subcutaneous tissue from underlying fascia. When conservative treatment fails, surgical treatment is imperative. Commonly, open drainage and debridement is performed. This case report describes a Morel-Lavallée lesion of the knee in a professional soccer player who was successfully treated with endoscopic debridement and fibrin glue injection after failure of conservative management. This method achieves the goal of an open surgical debridement without exposing patients to an increased morbidity. Copyright © 2016. Published by Elsevier B.V.

  13. Predicting Treatment Response to Intra-arterial Therapies for Hepatocellular Carcinoma with the Use of Supervised Machine Learning-An Artificial Intelligence Concept.

    Science.gov (United States)

    Abajian, Aaron; Murali, Nikitha; Savic, Lynn Jeanette; Laage-Gaupp, Fabian Max; Nezami, Nariman; Duncan, James S; Schlachter, Todd; Lin, MingDe; Geschwind, Jean-François; Chapiro, Julius

    2018-06-01

    To use magnetic resonance (MR) imaging and clinical patient data to create an artificial intelligence (AI) framework for the prediction of therapeutic outcomes of transarterial chemoembolization by applying machine learning (ML) techniques. This study included 36 patients with hepatocellular carcinoma (HCC) treated with transarterial chemoembolization. The cohort (age 62 ± 8.9 years; 31 men; 13 white; 24 Eastern Cooperative Oncology Group performance status 0, 10 status 1, 2 status 2; 31 Child-Pugh stage A, 4 stage B, 1 stage C; 1 Barcelona Clinic Liver Cancer stage 0, 12 stage A, 10 stage B, 13 stage C; tumor size 5.2 ± 3.0 cm; number of tumors 2.6 ± 1.1; and 30 conventional transarterial chemoembolization, 6 with drug-eluting embolic agents). MR imaging was obtained before and 1 month after transarterial chemoembolization. Image-based tumor response to transarterial chemoembolization was assessed with the use of the 3D quantitative European Association for the Study of the Liver (qEASL) criterion. Clinical information, baseline imaging, and therapeutic features were used to train logistic regression (LR) and random forest (RF) models to predict patients as treatment responders or nonresponders under the qEASL response criterion. The performance of each model was validated using leave-one-out cross-validation. Both LR and RF models predicted transarterial chemoembolization treatment response with an overall accuracy of 78% (sensitivity 62.5%, specificity 82.1%, positive predictive value 50.0%, negative predictive value 88.5%). The strongest predictors of treatment response included a clinical variable (presence of cirrhosis) and an imaging variable (relative tumor signal intensity >27.0). Transarterial chemoembolization outcomes in patients with HCC may be predicted before procedures by combining clinical patient data and baseline MR imaging with the use of AI and ML techniques. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  14. Transarterial chemoembolization plus or minus intravenous bevacizumab in the treatment of hepatocellular cancer: A pilot study

    International Nuclear Information System (INIS)

    Britten, Carolyn D; Gomes, Antoinette S; Wainberg, Zev A; Elashoff, David; Amado, Rafael; Xin, Yan; Busuttil, Ronald W; Slamon, Dennis J; Finn, Richard S

    2012-01-01

    Stimulation of vascular endothelial growth factor (VEGF) has been observed following transarterial chemoembolization (TACE) in hepatocellular cancer (HCC) and may contribute to tumor regrowth. This pilot study examined whether intravenous (IV) bevacizumab, a monoclonal antibody against VEGF, could inhibit neovessel formation after TACE. 30 subjects with HCC undergoing TACE at a single academic institution were randomized with a computer-generated allocation in a one to one ratio to either bevacizumab at a dose of 10 mg/kg IV every 14 days beginning 1 week prior to TACE (TACE-BEV arm) or observation (TACE-O arm). Angiography was performed with TACE at day 8, and again at weeks 10 and 14. Repeat TACE was performed at week 14 if indicated. TACE-BEV subjects were allowed to continue bevacizumab beyond week 16. TACE-O subjects were allowed to cross-over to bevacizumab at week 16 in the setting of progressive disease. The main outcome measure was a comparison of neovessel formation by serial angiography. Secondary outcome measures were progression free survival (PFS) at 16 weeks, overall survival (OS), bevacizumab safety, and an analysis of VEGF levels before and after TACE with and without bevacizumab. Among the 30 subjects enrolled, 9 of 15 randomized to the TACE-O arm and 14 of 15 randomized to the TACE-BEV arm completed all 3 angiograms. At week 14, 3 of 9 (33%) TACE-O subjects and 2 of 14 (14%) TACE-BEV subjects demonstrated neovascularity. The PFS at 16 weeks was 0.19 in the TACE-O arm and 0.79 in the TACE-BEV arm (p = 0.021). The median OS was 61 months in the TACE-O arm and 49 months in the TACE-BEV arm (p = 0.21). No life-threatening bevacizumab-related toxicities were observed. There were no substantial differences in bevacizumab pharmacokinetics compared to historical controls. Bevacizumab attenuated the increase in VEGF observed post-TACE. IV bevacizumab was well tolerated in selected HCC subjects undergoing TACE, and appeared to diminish neovessel formation

  15. Transarterial chemoembolization combined with sorafenib for the treatment of hepatocellular carcinoma with hepatic vein tumor thrombus

    Directory of Open Access Journals (Sweden)

    Zhang YF

    2016-07-01

    Full Text Available Yong-Fa Zhang,1–3,* Wei Wei,1–3,* Jia-Hong Wang,1–3,* Li Xu,1–3 Pei-En Jian,1–3 Cheng-Zuo Xiao,4 Xiao-Ping Zhong,1–3 Ming Shi,1–3 Rong-Ping Guo1–3 1Department of Hepatobiliary Oncology, Sun Yat-sen University Cancer Center, 2State Key Laboratory of Oncology in South China, 3Collaborative Innovation Center for Cancer Medicine, Guangzhou, 4Department of General Surgery, Shenzhen Shajing Affiliated Hospital of Guangzhou Medical University, Shenzhen, People’s Republic of China *These authors contributed equally to this work Objective: To compare the treatment outcomes of sorafenib plus transarterial chemoembolization (TACE vs TACE alone in patients with hepatocellular carcinoma (HCC and hepatic vein tumor thrombus (HVTT.Methods: Twenty patients who were initially diagnosed with HCC and HVTT and received TACE combined with sorafenib during February 2009 to October 2013 were included in the study. To minimize selection bias, these patients were compared with 60 case-matched controls selected from a pool of 81 patients (in a 1:3 ratio who received TACE alone during the same period. The primary end point was overall survival (OS. The secondary end points were time to progression, disease control rate, and adverse events.Results: After a median follow-up period of 12.5 months (range, 1.03–44.23 months, the OS of the combined group was found to be significantly higher compared with the monotherapy group (14.9 vs 6.1 months, P=0.010. The time to progression was found to be significantly longer in the combined group (4.9 vs 2.4 months, P=0.016. Univariate and multivariate analyses revealed that the treatment allocation was an independent predictor of OS.Conclusion: Sorafenib plus TACE was well tolerated and was more effective in treating patients with advanced HCC and HVTT. Future trials with prospective larger samples are required to validate these results. Keywords: hepatocellular carcinoma, hepatic vein tumor thrombus, prognosis

  16. Alternative Techniques for Cannulation of Biliary Strictures Resistant to the 0.035 System Following Living Donor Liver Transplantation

    International Nuclear Information System (INIS)

    Yoon, Hee Mang; Kim, Jin Hyoung; Ko, Gi Young; Song, Ho Young; Gwon, Dong Il; Sung, Kyu Bo

    2012-01-01

    To assess the clinical efficacy of alternative techniques for biliary stricture cannulation in patients undergoing living donor liver transplantation (LDLT), after cannulation failure with a conventional (0.035-inch guidewire) technique. Of 293 patients with biliary strictures after LDLT, 19 (6%) patients, 11 men and 8 women of mean age 48.5 years, had the failed cannulation of the stricture by conventional techniques. Recannulation was attempted by using two alternative methods, namely a micro-catheter set via percutaneous access and a snare (rendezvous) technique using percutaneous and endoscopic approaches. Strictures were successfully cannulated in 16 (84%) of the 19 patients. A microcatheter set was used in 12 and a snare technique in four patients. Stricture cannulation failed in the remaining three patients, who finally underwent surgical revision. Most technical failures using a conventional technique for biliary stricture cannulation after LDLT can be overcome by using a microcatheter set or a snare (rendezvous) technique.

  17. Alternative Techniques for Cannulation of Biliary Strictures Resistant to the 0.035 System Following Living Donor Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hee Mang; Kim, Jin Hyoung; Ko, Gi Young; Song, Ho Young; Gwon, Dong Il; Sung, Kyu Bo [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-03-15

    To assess the clinical efficacy of alternative techniques for biliary stricture cannulation in patients undergoing living donor liver transplantation (LDLT), after cannulation failure with a conventional (0.035-inch guidewire) technique. Of 293 patients with biliary strictures after LDLT, 19 (6%) patients, 11 men and 8 women of mean age 48.5 years, had the failed cannulation of the stricture by conventional techniques. Recannulation was attempted by using two alternative methods, namely a micro-catheter set via percutaneous access and a snare (rendezvous) technique using percutaneous and endoscopic approaches. Strictures were successfully cannulated in 16 (84%) of the 19 patients. A microcatheter set was used in 12 and a snare technique in four patients. Stricture cannulation failed in the remaining three patients, who finally underwent surgical revision. Most technical failures using a conventional technique for biliary stricture cannulation after LDLT can be overcome by using a microcatheter set or a snare (rendezvous) technique.

  18. Intraprocedural blood volume measurement using C-arm CT as a predictor for treatment response of malignant liver tumours undergoing repetitive transarterial chemoembolization (TACE)

    International Nuclear Information System (INIS)

    Vogl, Thomas J.; Schaefer, Patrik; Lehnert, Thomas; Mbalisike, Emmanuel; Hammerstingl, Renate; Eichler, Katrin; Zangos, Stephan; Nour-Eldin, Nour-Eldin A.; Ackermann, Hanns; Naguib, Nagy N.N.

    2016-01-01

    To evaluate feasibility of measuring parenchymal blood volume (PBV) of malignant hepatic tumours using C-arm CT, test the changes in PBV following repeated transarterial chemoembolization (TACE) and correlate these changes with the change in tumour size in MRI. 111 patients with liver malignancy were included. Patients underwent MRI and TACE in a 4- to 6-week interval. During intervention C-arm CT was performed. Images were post-processed to generate PBV maps. Blood volume data in C-arm CT and change in size in MRI were evaluated. The correlation between PBV and size was tested using Spearman rank test. Pre-interventional PBV maps showed a mean blood volume of 84.5 ml/1000 ml ± 62.0, follow-up PBV maps after multiple TACE demonstrated 61.1 ml/1000 ml ± 57.5. The change in PBV was statistically significant (p = 0.02). Patients with initial tumour blood volume >100 ml/1000 ml dropped 7.1 % in size and 47.2 % in blood volume; 50-100 ml/1000 ml dropped 4.6 % in size and 25.7 % in blood volume; and <50 ml/1000 ml decreased 2.8 % in size and increased 82.2 % in blood volume. PBV measurement of malignant liver tumours using C-arm CT is feasible. Following TACE PBV decreased significantly. Patients with low initial PBV show low local response rates and further increase in blood volume, whereas high initial tumour PBV showed better response to TACE. (orig.)

  19. Benefits of sinogram-affirmed iterative reconstruction in 0.4 mSv ultra-low-dose CT of the upper abdomen following transarterial chemoembolisation: comparison to low-dose and standard-dose CT and filtered back projection technique

    International Nuclear Information System (INIS)

    Bodelle, B.; Isler, S.; Scholtz, J.-E.; Frellesen, C.; Luboldt, W.; Vogl, T.J.; Beeres, M.

    2016-01-01

    Aim: To evaluate the advantage of sinogram-affirmed iterative reconstruction (SIR) compared to filtered back projection (FBP) in upper abdomen computed tomography (CT) after transarterial chemoembolisation (TACE) at different tube currents. Materials and methods: The study was approved by the institutional review board. Written informed consent was obtained from all patients. Post-TACE CT was performed with different tube currents successively varied in four steps (180, 90, 45 and 23 mAs) with 40 patients per group (mean age: 60±12 years, range: 23–85 years, sex: 70 female, 90 male). The data were reconstructed with standard FBP and five different SIR strengths. Image quality was independently rated by two readers on a five-point scale. High (Lipiodol-to-liver) as well as low (liver-to-fat) contrast-to-noise ratios (CNRs) were intra-individually compared within one dose to determine the optimal strength (S1–S5) and inter-individually between different doses to determine the possibility of dose reduction using the Kruskal–Wallis test. Results: Subjective image quality and objective CNR analysis were concordant: intra-individually, SIR was significantly (p<0.001) superior to FBP. Inter-individually, regarding different doses (180 versus 23 ref mAs), there was no significant (p=1.00) difference when using S5 SIR at 23 mAs instead of FBP. Conclusion: SIR allows for an 88% dose reduction from 3.43 to 0.4 mSv in unenhanced CT of the liver following TACE without subjective or objective loss in image quality. - Highlights: • Diagnostic image quality and radiation dose of ultra-low-dose CT of the upper abdomen using sinogram affirmed iterative reconstruction following transarterial chemoembolization in comparison to low-dose and standard dose CT and filtered back projection technique. • Ultra-low dose CT of the upper abdomen using sinogram affirmed iterative reconstruction allows for significant dose reduction by 88%. • Ultra-low dose CT of the upper abdomen

  20. Autologous fibrin glue as an encapsulating scaffold for delivery of retinal progenitor cells

    Directory of Open Access Journals (Sweden)

    Tamer Anwar Esmail Ahmed

    2015-02-01

    Full Text Available The retina is a highly sophisticated piece of the neural machinery that begins the translation of incoming light signals into meaningful visual information. Several degenerative diseases of the retina are characterized by photoreceptor loss and eventually lead to irreversible blindness. Regenerative medicine, using tissue engineering-based constructs to deliver progenitor cells or photoreceptors along with supporting carrier matrix is a promising approach for restoration of structure and function. Fresh fibrin glue (FG produced by the CryoSeal®FS system in combination with mouse retinal progenitor cells (RPCs were evaluated in this study. In vitro expanded RPCs isolated from postnatal mouse retina were encapsulated into FG and cultured in the presence of the protease inhibitor, tranexamic acid. Encapsulation of RPCs into FG did not show adverse effects on cell proliferation or cell survival. RPCs exhibited fibroblast-like morphology concomitantly with attachment to the encapsulating FG surface. They expressed α7 and β3 integrin subunits that could mediate attachment to fibrin matrix via an RGD independent mechanism. The three dimensional environment and the attachment surface provided by FG was associated with a rapid downregulation of the progenitor marker SOX2 and enhanced the expression of the differentiation markers CRX and recoverin. However, the in vitro culture conditions did not promote full differentiation into mature photoreceptors. Nevertheless, we have shown that autologous fibrin, when fabricated into a scaffold for RPCs for delivery to the retina, provides the cells with external cues that could potentially improve the differentiation events. Hence, transient encapsulation of RPCs into FG could be a valid and potential treatment strategy to promote retinal regeneration following degenerative diseases. However, further optimization is necessary to maximize the outcomes in terms of mature photoreceptors.

  1. [Comparison liver resection with transarterial chemoembolization for Barcelona Clinic Liver Cancer stage B hepatocellular carcinoma patients on long-term survival after SPSS propensity score matching].

    Science.gov (United States)

    Ke, Yang; Zhong, Jianhong; Guo, Zhe; Liang, Yongrong; Li, Lequn; Xiang, Bangde

    2014-03-18

    To compare the long-term survival of patients with Barcelona Clinic Liver Cancer (BCLC) stage B hepatocellular carcinoma (HCC) undergoing either liver resection or transarterial chemoembolization (TACE) after propensity score matching (PSM). One hundred sixty-seven and 70 BCLC-B HCC patients undergoing liver resection and TACE were retrospectively collected. PSM function of SPSS software was conducted to reduce confounding bias between the groups. And then survival analysis was performed for the matched data. Fifty-three pairs of patients were successfully matched. And then survival analysis showed that the median survival periods and their 95% confidence intervals were 35.0 (26.3-43.7)months in the liver resection group versus 20.0(15.0-25.0) months in the TACE group. The 1, 3, 5 and 7-year survival rates were 91.0%, 49.0%, 30.0% and 17.0% in the liver resection group versus 73.0%, 25.0%, 8.0% and 5.0% respectively in the TACE group (P = 0.001). Cox regression analysis revealed that TACE, total bilirubin ≥ 34.2 µmol/L, alpha fetoprotein ≥ 400 ng/ml and tumor number ≥ 3 were independent risk factors of survival (hazard ratio >1, P < 0.05). The balance of covariates may be achieved through PSM. And for patients with BCLC-B HCC, liver resection provides better long-term overall survival than TACE.

  2. Comparison of the effects of transarterial chemoembolization for advanced hepatocellular carcinoma between patients with and without extrahepatic metastases.

    Directory of Open Access Journals (Sweden)

    Jeong-Ju Yoo

    Full Text Available Sorafenib is a standard treatment for advanced hepatocellular carcinoma (HCC (Barcelona Clinic Liver Cancer [BCLC] stage C. However, transarterial chemoembolization (TACE has also been widely used as a treatment for patients with advanced HCC, even if they have extrahepatic metastases (EHM. The aim of this study was to determine the efficacy of TACE for advanced HCC patients with EHM upon initial diagnosis, as compared with those patients without EHM.This cohort study involved consecutive patients who underwent TACE as an initial treatment for advanced HCC. One hundred seventy-seven patients with EHM (the EHM group and 205 with portal vein invasion without EHM (the non-EHM group were included. A survival analysis was performed to compare overall survival between the two groups.The mean age was 54.5±9.9 years, and median follow-up duration was 13.1 months (range, 0.5-111.0. Overall survival was significantly shorter in the EHM group than the non-EHM group (median, 8.3 vs. 19.1 months; P<0.001. A multivariate analysis showed that the presence of EHM was an independent poor prognostic factor for shorter overall survival (adjusted hazard ratio, 1.74; 95% confidence interval, 1.39-2.17; P<0.001 after adjustment for Child-Pugh classification, intrahepatic tumor T classification, tumor response to TACE, and serum alpha-fetoprotein level. Patients administered TACE and systemic therapy demonstrated a better survival rate than those administered TACE alone in both the EHM (median, 13.5 vs. 7.2 months and non-EHM groups (median, 27.9 vs. 18.2 months (both, P<0.05.The prognosis of advanced HCC patients with EHM is significantly worse than those without EHM administered repeated TACE treatments, even if their tumor stage was similar to BCLC stage C. These results suggest that EHM presence means aggressive tumor biology and that BCLC stage C might be subclassified according to EHM presence.

  3. Superselective transarterial chemoembolization vs hepatic resection for resectable early-stage hepatocellular carcinoma in patients with Child-Pugh class a liver function

    International Nuclear Information System (INIS)

    Hsu, Kuo-Feng; Chu, Chi-Hung; Chan, De-Chuan; Yu, Jyh-Cherng; Shih, Ming-Lang; Hsieh, Huan-Fa; Hsieh, Tsai-Yuan; Yu, Chih-Yung; Hsieh, Chung-Bao

    2012-01-01

    Purpose: In contrast to hepatic resection (HR) for resectable early-stage HCC, the efficacy of transarterial chemoembolization (TACE) is controversial. This study is designed to compare the long-term outcome of TACE using superselective technique with hepatic resection for the treating resectable early-stage HCC and Child-Pugh class A liver function. Methods: In total, 185 consecutive patients with resectable early-stage HCC and Child-Pugh class A liver function were included: 73 patients received superselective TACE (group I) and 112 patients underwent HR (group II). We evaluated the therapy-related recurrence and long-term outcome and in both groups. The risk factors of recurrence and mortality were assessed by Cox's model. Results: The mean survival time of group 1 patient was similar to that of group 2 patient (40.8 ± 19.8 vs 46.7 ± 24.6 months respectively, p = 0.91). The 1-, 3-, and 5-year overall survival rates after TACE (group I)and HR (group II) were 91%, 66%, and 52% and 93%, 71%, and 57%, respectively (p = 0.239). The 1-, 3-, and 5-year recurrence-free survival rates in groups 1 and 2 were 68%, 28%, and 17% and 78%, 55%, and 35%, respectively (p < 0.0001). Serum albumin, tumour size, tumour number and recurrence interval were independent risk factors for mortality. Serum albumin level, tumour size, tumour number, and treatment modality of TACE or HR could predict HCC recurrence. Conclusion: TACE is an efficient and safe treatment for resectable early-stage HCC with overall survival rates similar to that of HR. Thus, TACE is indicated in selected patients with resectable early-stage HCC.

  4. Locally induced hypothermia for treatment of acute ischaemic stroke: A physical feasibility study

    International Nuclear Information System (INIS)

    Slotboom, J.; Kiefer, C.; Brekenfeld, C.; Ozdoba, C.; Remonda, L.; Nedeltchev, K.; Schroth, G.; Arnold, M.; Mattle, H.

    2004-01-01

    During the treatment of stroke by local intra-arterial thrombolysis (LIT) it is frequently possible to pass the blood clot with a micro-catheter, allowing perfusion of brain tissue distally to the occlusion. This possibility allows for new early treatments of ischaemic brain tissue, even before the blood clot has been removed. One potential new approach to preserve brain tissue at risk may be locally induced endovascular hypothermia. Physical parameters such as the required micro-catheter input pressure, output velocity and flow rates, and a heat exchange model, applicable in the case of a micro-catheter placed within a guiding catheter, are presented. Also, a simple cerebral temperature model is derived that models the temperature response of the brain to the perfusion with coolant fluids. Based on this model, an expression has been derived for the time needed to reach a certain cerebral target temperature. Experimental in vitro measurements are presented that confirm the usability of standard commercially available micro-catheters to induce local hypothermia of the brain. If applied in vivo, the model predicts a local cooling rate of ischaemic brain tissue of 300 g of approximately 1 C in 1 min, which is up to a factor 30-times faster than the time-consuming systemic hypothermia via the skin. Systemic body temperature is only minimally affected by application of local hypothermia, thus avoiding many limitations and complications known in systemic hypothermia. (orig.)

  5. Locally induced hypothermia for treatment of acute ischaemic stroke: A physical feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Slotboom, J.; Kiefer, C.; Brekenfeld, C.; Ozdoba, C.; Remonda, L.; Nedeltchev, K.; Schroth, G. [Inselspital, Institute of Diagnostic and Interventional Neuroradiology, University of Bern, Berne (Switzerland); Arnold, M.; Mattle, H. [University of Bern, Department of Neurology, Berne (Switzerland)

    2004-11-01

    During the treatment of stroke by local intra-arterial thrombolysis (LIT) it is frequently possible to pass the blood clot with a micro-catheter, allowing perfusion of brain tissue distally to the occlusion. This possibility allows for new early treatments of ischaemic brain tissue, even before the blood clot has been removed. One potential new approach to preserve brain tissue at risk may be locally induced endovascular hypothermia. Physical parameters such as the required micro-catheter input pressure, output velocity and flow rates, and a heat exchange model, applicable in the case of a micro-catheter placed within a guiding catheter, are presented. Also, a simple cerebral temperature model is derived that models the temperature response of the brain to the perfusion with coolant fluids. Based on this model, an expression has been derived for the time needed to reach a certain cerebral target temperature. Experimental in vitro measurements are presented that confirm the usability of standard commercially available micro-catheters to induce local hypothermia of the brain. If applied in vivo, the model predicts a local cooling rate of ischaemic brain tissue of 300 g of approximately 1 C in 1 min, which is up to a factor 30-times faster than the time-consuming systemic hypothermia via the skin. Systemic body temperature is only minimally affected by application of local hypothermia, thus avoiding many limitations and complications known in systemic hypothermia. (orig.)

  6. First Human Experience with Directly Image-able Iodinated Embolization Microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Elliot B., E-mail: levyeb@cc.nih.gov; Krishnasamy, Venkatesh P. [National Institutes of Health, Center for Interventional Oncology (United States); Lewis, Andrew L.; Willis, Sean; Macfarlane, Chelsea [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Anderson, Victoria [National Institutes of Health, Center for Interventional Oncology (United States); Bom, Imramsjah MJ van der [Clinical Science IGT Systems North & Latin America, Philips, Philips, Image Guided Interventions (United States); Radaelli, Alessandro [Image-Guided Therapy Systems, Philips, Philips, Image Guided Interventions (Netherlands); Dreher, Matthew R. [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Sharma, Karun V. [Children’s National Medical Center (United States); Negussie, Ayele; Mikhail, Andrew S. [National Institutes of Health, Center for Interventional Oncology (United States); Geschwind, Jean-Francois H. [Department of Radiology and Biomedical Imaging (United States); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology (United States)

    2016-08-15

    PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.

  7. Anastomose do nervo facial de coelhos com cola de fibrina: estudo da velocidade de condução nervosa Rabbit facial nerve anastomosis with fibrin glue: nerve conduction velocity evaluation

    Directory of Open Access Journals (Sweden)

    Francisco Aurelio Lucchesi Sandrini

    2007-04-01

    Full Text Available OBJETIVO: Este estudo tem o objetivo de avaliar através da velocidade de condução nervosa com eletrodos de superfície a utilização da cola de fibrina na anastomose nervosa. MÉTODOS: Neste experimento, foram avaliadas as diferenças entre as velocidades de condução nervosa pré e pós-operatória do nervo facial esquerdo de 12 coelhos. Foi verificada a existência de correlação entre a velocidade de condução nervosa e o número de axônios regenerados no pós-operatório. Os nervos transeccionados foram unidos com cola de fibrina. O potencial de ação motora foi obtido com o uso de eletrodos de superfície. O eletrodo de estimulação foi colocado imediatamente à frente do pavilhão auditivo (tronco do nervo facial e o eletrodo de gravação foi colocado no músculo quadrado do lábio inferior. RESULTADOS: A média normal da velocidade de condução nervosa foi de 36,53 m/seg. Ao final do período, a velocidade de condução nervosa atingiu um valor de aproximadamente 81% do valor normal. Não foi observada correlação significativa entre a velocidade de condução nervosa pós-operatória e o número de axônios regenerados (p=0,146. CONCLUSÃO: A anastomose com cola de fibrina pode ser utilizada para anastomose nervosa no modelo animal e nervo estudados.AIM: The aim of this study was to evaluate the use of fibrin glue on nerve anastomosis, and study conduction velocity obtained by surface electrodes. METHODS: In this experimental model we evaluated nerve conduction velocity differences in the preoperative and postoperative periods, for the left facial nerve of 12 rabbits. Then, we evaluated whether there were correlations between conduction velocity and the number of postoperative regenerated axons. The sectioned nerves were anastomosed with fibrin glue. The muscle action potentials were obtained from surface electrodes. The stimulation electrode was placed immediately before the ear pinna (facial nerve trunk and the recording

  8. Amplatzer Vascular Plug Anchoring Technique to Stabilize the Delivery System for Microcoil Embolization

    International Nuclear Information System (INIS)

    Onozawa, Shiro; Murata, Satoru; Mine, Takahiko; Sugihara, Fumie; Yasui, Daisuke; Kumita, Shin-ichiro

    2016-01-01

    PurposeTo evaluate the feasibility of a novel embolization technique, the Amplatzer vascular plug (AVP) anchoring technique, to stabilize the delivery system for microcoil embolization.Materials and methodsThree patients were enrolled in this study, including two cases of internal iliac artery aneurysms and one case of internal iliac arterial occlusion prior to endovascular aortic repair. An AVP was used in each case for embolization of one target artery, and the AVP was left in place. The AVP detachment wire was then used as an anchor to stabilize the delivery system for microcoil embolization to embolize the second target artery adjacent to the first target artery. The microcatheter for the microcoils was inserted parallel to the AVP detachment wire in the guiding sheath or catheter used for the AVP.ResultsThe AVP anchoring technique was achieved and the microcatheter was easily advanced to the second target artery in all three cases.ConclusionThe AVP anchoring technique was found to be feasible to advance the microcatheter into the neighboring artery of an AVP-embolized artery.

  9. Treatment of non-healing sternum wound after open-heart surgery with allogenic platelet-rich plasma and fibrin glue-preliminary outcomes

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasi Tashnizi

    2013-01-01

    Full Text Available Introduction: Non-healing wound in the sternal region after coronary arteries bypass graft surgery is a serious complication. For healing a chronic wound, several novel approaches have been proposed recently such as using bone marrow stem cells, platelets and fibrin glue (PFG; but a non-invasive method is highly desirable in the first approach for treatment. The current study was undertaken to evaluate the effect of the combination of PFG in one treatment. Materials and Methods: We report on the treatment of six patients with life-threatening chronic sternum wounds, which caused septicemia with multi-drug resistant pathogens. The ulcers were extensively debrided initially and were measured and photographed at weekly intervals. The combination of PFG was applied topically on the wound after every 2 days. Results: The wounds were completely closed in five patients and significantly reduced in size in one. There was no evidence of local or systemic complications and any abnormal tissue formation, keloid or hypertrophic scarring. Conclusions: Our study suggests, in the first approach, PFG can be used safely in order to heal a non healing sternum wound following coronary artery bypass surgery.

  10. Histogram Analysis of CT Perfusion of Hepatocellular Carcinoma for Predicting Response to Transarterial Radioembolization: Value of Tumor Heterogeneity Assessment

    International Nuclear Information System (INIS)

    Reiner, Caecilia S.; Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz; Schaefer, Niklaus; Veit-Haibach, Patrick; Pfammatter, Thomas; Alkadhi, Hatem

    2016-01-01

    PurposeTo evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE).Materials and MethodsSixteen patients (15 male; mean age 65 years; age range 47–80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters’ ability to discriminate responders from non-responders.ResultsAccording to mRECIST, 8 patients (50 %) were responders and 8 (50 %) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min −1  100 mL −1 ); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min −1  100 mL −1 ; p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min −1  100 mL −1 , therapy response could be predicted with a sensitivity of 88 % (7/8) and specificity of 75 % (6/8).ConclusionVoxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE

  11. Randomized Clinical Trial Comparing Proton Beam Radiation Therapy with Transarterial Chemoembolization for Hepatocellular Carcinoma: Results of an Interim Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bush, David A., E-mail: dbush@llu.edu [Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California (United States); Smith, Jason C. [Department of Diagnostic Radiology, Loma Linda University Medical Center, Loma Linda, California (United States); Slater, Jerry D. [Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California (United States); Volk, Michael L. [Transplantation Institute and Liver Center, Loma Linda University Medical Center, Loma Linda, California (United States); Reeves, Mark E. [VA Loma Linda Health Care System, Loma Linda, California (United States); Cheng, Jason [Transplantation Institute and Liver Center, Loma Linda University Medical Center, Loma Linda, California (United States); Grove, Roger [Department of Radiation Medicine, Loma Linda University Medical Center, Loma Linda, California (United States); Vera, Michael E. de [Transplantation Institute and Liver Center, Loma Linda University Medical Center, Loma Linda, California (United States)

    2016-05-01

    Purpose: To describe results of a planned interim analysis of a prospective, randomized clinical trial developed to compare treatment outcomes among patients with newly diagnosed hepatocellular carcinoma (HCC). Methods and Materials: Eligible subjects had either clinical or pathologic diagnosis of HCC and met either Milan or San Francisco transplant criteria. Patients were randomly assigned to transarterial chemoembolization (TACE) or to proton beam radiation therapy. Patients randomized to TACE received at least 1 TACE with additional TACE for persistent disease. Proton beam radiation therapy was delivered to all areas of gross disease to a total dose of 70.2 Gy in 15 daily fractions over 3 weeks. The primary endpoint was progression-free survival, with secondary endpoints of overall survival, local tumor control, and treatment-related toxicities as represented by posttreatment days of hospitalization. Results: At the time of this analysis 69 subjects were available for analysis. Of these, 36 were randomized to TACE and 33 to proton. Total days of hospitalization within 30 days of TACE/proton was 166 and 24 days, respectively (P<.001). Ten TACE and 12 proton patients underwent liver transplantation after treatment. Viable tumor identified in the explanted livers after TACE/proton averaged 2.4 and 0.9 cm, respectively. Pathologic complete response after TACE/proton was 10%/25% (P=.38). The 2-year overall survival for all patients was 59%, with no difference between treatment groups. Median survival time was 30 months (95% confidence interval 20.7-39.3 months). There was a trend toward improved 2-year local tumor control (88% vs 45%, P=.06) and progression-free survival (48% vs 31%, P=.06) favoring the proton beam treatment group. Conclusions: This interim analysis indicates similar overall survival rates for proton beam radiation therapy and TACE. There is a trend toward improved local tumor control and progression-free survival with proton beam. There are

  12. Effect of Angelica Sinensis on liver fibrosis after radiotherapy combined with transarterial chemoembolization for rabbits with VX 2 tumor

    International Nuclear Information System (INIS)

    Long Qingyun; Zhou Yunfeng; Hu Jinxiang; Zhou Jun; Le Tao

    2008-01-01

    Objective: To evaluate the effect of Angelica Sinensis on liver fibrosis after radiotherapy (RT) combined with transarterial chemoembolization(TACE) for rabbits with VX 2 tumor, and the mechanism of anti-hepatic fibrosis. Methods: Fifty New Zealand white rabbits were divided randomly into three groups: Control group (n=10) was given saline 2 ml by gastroduodenal artery, model group (n=10) was given pingyangmycin 1 mg and iodized oil 0.2 ml, and exposed to single fraction of 20 Gy, Angelica group (n=30) undergoing RT combined with TACE was given Angelica Sinensis injection. According to different doses of Angelica Sinensis, Angelica group was divided into low-dose group (4 ml/kg), middle dose group (6 ml/kg) and high-dose group (8 ml/kg), twice per week for 4 weeks. Serum levels of HA, LN, PCIII, CIV and liver specimens were obtained at the end of 6th week after RT combined with TACE. The histological changes were determined by HE, VG staining and TGF-β1 immunohistochemistry staining. Results: Stages of liver fibrosis in the model group were mostly stages II and III, and stages of liver fibrosis in the Angelica group were mostly stages I, there was significant difference between the model group and the Angelica group, and stages of liver fibrosis were associated with Angelica intercention treatment (r=0.7631, P<0.01). Serum HA, LN, PCIII and CIV in the model group were higher than those in the control group(P<0.01), TGF-β1 expression in the Angelica group was significantly reduced compared with the wodel group and different doses of Angelica group showed dose-effect (r=0.4427, P<0.01). Conclusions: Angelica Sinensis injection has inhibitive effect on liver fibrosis after RT combined with TACE for rabbits with VX 2 tumor, the mechanism of anti-hepatic fibrosis might possibly be associated with down-regulating TGF-β1. (authors)

  13. Fixação de enxerto cutâneo em malha de espessura total com sutura ou cola de fibrina Fixation of full-thickness mesh skin using suture or fibrin glue

    Directory of Open Access Journals (Sweden)

    M.S.P. Amaral

    2004-06-01

    Full Text Available Avaliou-se a influência da cola de fibrina, derivada do veneno de serpente, na fixação e integração de enxerto de pele. Foram utilizados nove cães, sem raça definida, com peso médio de 15kg. Foi induzida ferida de 4×4cm de área, na face crânio-proximal dos antebraços direito e esquerdo. Um enxerto de espessura total foi colhido da região torácica e expandido por meio de expansor de pele. No membro direito o enxerto foi estabilizado no leito receptor por meio de pontos isolados simples; no esquerdo foi fixado pela aplicação de cola de fibrina e oito pontos de sutura. O sítio doador foi fechado empregando-se retalho cutâneo bipediculado. As bandagens do leito receptor foram oclusivas e não aderentes e aplicou-se pomada de neomicina com bacitracina. A troca de bandagens ocorreu diariamente até o sétimo dia de pós-operatório e, posteriormente, a cada três dias. A área de sobrevivência do enxerto foi obtida pela subtração das áreas não viáveis e total medidas com fotomicroscópio Nikon conectado a um sistema de análise de imagem KS-300 aos três, sete, 15 e 30 dias de pós-operatório. Para a avaliação microscópica, a área do enxerto foi colhida em três animais aos sete, 15 e 30 dias de pós-operatório. Não houve diferença entre momentos de avaliação e técnicas de fixação quanto à área de enxerto viável. Os enxertos fixados com cola apresentaram estágio de reparação mais avançado em todos os momentos. Concluiu-se que a cola de fibrina derivada do veneno de serpente tem moderado poder adesivo e, pela análise microscópica, favorece a integração do enxerto cutâneo em malha de espessura total.The purpose of this study was to evaluate the efficiency of fibrin glue, derived from snake venom, on fixation and integration of skin graft. Nine crossbred dogs, with average weight of 15kg were used. Wounds measuring 4×4 cm were induced at the cranioproximal aspect of the right and left forelimb. Full

  14. Efficacy of multifunnel traps for capturing emerald ash borer (Coleoptera: Buprestidae): effect of color, glue, and other trap coatings.

    Science.gov (United States)

    Francese, Joseph A; Fraser, Ivich; Lance, David R; Mastro, Victor C

    2011-06-01

    Tens of thousands of adhesive-coated purple prism traps are deployed annually in the United States to survey for the invasive emerald ash borer, Agrilus planipennis Fairmaire (Coleoptera: Buprestidae). A reusable, more user-friendly trap is desired by program managers, surveyors, and researchers. Field assays were conducted in southeastern Michigan to ascertain the feasibility of using nonsticky traps as survey and detection tools for emerald ash borer. Three nonsticky trap designs, including multifunnel (Lindgren), modified intercept panel, and drainpipe (all painted purple) were compared with the standard purple prism trap; no statistical differences in capture of emerald ash borer adults were detected between the multifunnel design and the prism. In subsequent color comparison assays, both green- and purple-painted multifunnel traps (and later, plastic versions of these colors) performed as well or better than the prism traps. Multifunnel traps coated with spray-on adhesive caught more beetles than untreated traps. The increased catch, however, occurred in the traps' collection cups and not on the trap surface. In a separate assay, there was no significant difference detected between glue-coated traps and Rain-X (normally a glass treatment)-coated traps, but both caught significantly more A. planipennis adults than untreated traps.

  15. Crystal water as the mol-ecular glue for obtaining different co-crystal ratios: the case of gallic acid tris-caffeine hexa-hydrate.

    Science.gov (United States)

    Vella-Zarb, L; Baisch, U

    2018-04-01

    The crystal structure of the hexa-hydrate co-crystal of gallic acid and caffeine, C 7 H 6 O 5 ·3C 8 H 10 N 4 O 2 ·6H 2 O or GAL3CAF·6H 2 O , is a remarkable example of the importance of hydrate water acting as structural glue to facilitate the crystallization of two components of different stoichiometries and thus to compensate an imbalance of hydrogen-bond donors and acceptors. The water mol-ecules provide the additional hydrogen bonds required to form a crystalline solid. Whereas the majority of hydrogen bonds forming the inter-molecular network between gallic acid and caffeine are formed by crystal water, only one direct classical hydrogen bond between two mol-ecules is formed between the carb-oxy-lic oxygen of gallic acid and the carbonyl oxygen of caffeine with d ( D ⋯ A ) = 2.672 (2) Å. All other hydrogen bonds either involve crystal water or utilize protonated carbon atoms as donors.

  16. Lime-based restoration paints: characterization and evaluation of formulations using a native species from the Amazon flora and PVA-based glue as additives

    Directory of Open Access Journals (Sweden)

    Mayra Martins Silva

    Full Text Available Abstract Based on historic documents, two lime-based paint formulations were produced in laboratory in order to evaluate their basic characteristics as restoration materials for historic buildings with lime-based components. The paints were made basically with hydrated lime, clay, water and linseed (Linum usitatissimum L. oil, and one formulation had PVA (polyvinyl acetate-based glue as fixative, and the other one, Couma guianensis' latex. Each paint component was characterized by XRD and FTIR, and color and specular gloss measurements were performed on both paints. A preliminary assessment of the paints was conducted using the Pipe Method, the salt crystallization test, visual analysis for dustiness, and analysis of microbiological growth. The results showed that the laboratory-produced paints are theoretically and technologically compatible with lime-based coatings, however, their superficial performance can be improved to achieve greater durability. This study also brings to light local materials from the Amazon region that have great potential to be used and recognized as raw materials for paints and which could also be investigated for other uses.

  17. Balloon Blocking Technique (BBT) for Superselective Catheterization of Inaccessible Arteries with Conventional and Modified Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Morishita, Hiroyuki, E-mail: hmorif@koto.kpu-m.ac.jp, E-mail: mori-h33@xa2.so-net.ne.jp [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp [Kyoto Prefectural University of Medicine, Department of Radiology, North Medical Center (Japan); Ito, Takaaki, E-mail: takaaki@koto.kpu-m.ac.jp [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan); Hayashi, Natsuko, E-mail: hayashin@koto.kpu-m.ac.jp [Kyoto Prefectural University of Medicine, Department of Radiology, Graduate School of Medical Science (Japan); Sato, Osamu, E-mail: osamu-sato@kyoto1-jrc.org [Japan Red Cross Kyoto Daiichi Hospital, Department of Diagnostic Radiology (Japan)

    2016-06-15

    PurposeThe purpose of the study was to retrospectively evaluate the efficacy and safety of the balloon blocking technique (BBT).Materials and MethodsThe BBT was performed in six patients (all males, mean 73.5 years) in whom superselective catheterization for transcatheter arterial embolization by the conventional microcatheter techniques had failed due to anatomical difficulty, including targeted arteries originating steeply or hooked from parent arteries. All BBT procedures were performed using Seldinger’s transfemoral method. Occlusive balloons were deployed and inflated at the distal side of the target artery branching site in the parent artery via transfemoral access. A microcatheter was delivered from a 5-F catheter via another femoral access and was advanced over the microguidewire into the target artery, under balloon blockage of advancement of the microguidewire into non-target branches. After the balloon catheter was deflated and withdrawn, optimal interventions were performed through the microcatheter.ResultsAfter success of accessing the targeted artery by BBT, optimal interventions were accomplished in all patients with no complications other than vasovagal hypotension, which responded to nominal therapy.ConclusionThe BBT may be useful in superselective catheterization of inaccessible arteries due to anatomical difficulties.

  18. Glue protein production can be triggered by steroid hormone signaling independent of the developmental program in Drosophila melanogaster.

    Science.gov (United States)

    Kaieda, Yuya; Masuda, Ryota; Nishida, Ritsuo; Shimell, MaryJane; O'Connor, Michael B; Ono, Hajime

    2017-10-01

    Steroid hormones regulate life stage transitions, allowing animals to appropriately follow a developmental timeline. During insect development, the steroid hormone ecdysone is synthesized and released in a regulated manner by the prothoracic gland (PG) and then hydroxylated to the active molting hormone, 20-hydroxyecdysone (20E), in peripheral tissues. We manipulated ecdysteroid titers, through temporally controlled over-expression of the ecdysteroid-inactivating enzyme, CYP18A1, in the PG using the GeneSwitch-GAL4 system in the fruit fly Drosophila melanogaster. We monitored expression of a 20E-inducible glue protein gene, Salivary gland secretion 3 (Sgs3), using a Sgs3:GFP fusion transgene. In wild type larvae, Sgs3-GFP expression is activated at the midpoint of the third larval instar stage in response to the rising endogenous level of 20E. By first knocking down endogenous 20E levels during larval development and then feeding 20E to these larvae at various stages, we found that Sgs3-GFP expression could be triggered at an inappropriate developmental stage after a certain time lag. This stage-precocious activation of Sgs3 required expression of the Broad-complex, similar to normal Sgs3 developmental regulation, and a small level of nutritional input. We suggest that these studies provide evidence for a tissue-autonomic regulatory system for a metamorphic event independent from the primary 20E driven developmental progression. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Propensity Score Matching Analysis of Changes in Alpha-Fetoprotein Levels after Combined Radiotherapy and Transarterial Chemoembolization for Hepatocellular Carcinoma with Portal Vein Tumor Thrombus.

    Directory of Open Access Journals (Sweden)

    Yuri Jeong

    Full Text Available To investigate the value of changes in alpha-fetoprotein (AFP levels for the prediction of radiologic response and survival outcomes in hepatocellular carcinoma (HCC patients with portal vein tumor thrombus (PVTT who received combined treatment of 3-dimensional conformal radiotherapy (3D-CRT and transarterial chemoembolization (TACE.A database of 154 HCC patients with PVTT and elevated AFP levels (>20 ng/mL treated with 3D-CRT and TACE as an initial treatment between August 2002 and August 2008 was retrospectively reviewed. AFP levels were determined 1 month after radiotherapy, and AFP response was defined as an AFP level reduction of >20% from the initial level. Radiologic response, overall survival (OS, and progression-free survival (PFS rates were compared between AFP responders and non-responders. Propensity-score based matching analysis was performed to minimize the effect of potential confounding bias.The median follow-up period was 11.1 months (range, 3.1-82.7 months. In the propensity-score matching cohort (92 pairs, a best radiologic response of CR or PR occurred in more AFP responders than AFP non-responders (41.3% vs. 10.9%, p < 0.001. OS and PFS were also longer in AFP responders than in non-responders (median OS 13.2 months vs. 5.6 months, p < 0.001; median PFS 8.7 months vs. 3.5 months, p < 0.001.AFP response is a significant predictive factor for radiologic response. Furthermore, AFP response is significant for OS and PFS outcomes. AFP evaluation after combined radiotherapy and TACE appears to be a useful predictor of clinical outcomes in HCC patients with PVTT.

  20. Histogram Analysis of CT Perfusion of Hepatocellular Carcinoma for Predicting Response to Transarterial Radioembolization: Value of Tumor Heterogeneity Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Reiner, Caecilia S., E-mail: caecilia.reiner@usz.ch; Gordic, Sonja; Puippe, Gilbert; Morsbach, Fabian; Wurnig, Moritz [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology (Switzerland); Schaefer, Niklaus; Veit-Haibach, Patrick [University Hospital Zurich, Division of Nuclear Medicine (Switzerland); Pfammatter, Thomas; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology (Switzerland)

    2016-03-15

    PurposeTo evaluate in patients with hepatocellular carcinoma (HCC), whether assessment of tumor heterogeneity by histogram analysis of computed tomography (CT) perfusion helps predicting response to transarterial radioembolization (TARE).Materials and MethodsSixteen patients (15 male; mean age 65 years; age range 47–80 years) with HCC underwent CT liver perfusion for treatment planning prior to TARE with Yttrium-90 microspheres. Arterial perfusion (AP) derived from CT perfusion was measured in the entire tumor volume, and heterogeneity was analyzed voxel-wise by histogram analysis. Response to TARE was evaluated on follow-up imaging (median follow-up, 129 days) based on modified Response Evaluation Criteria in Solid Tumors (mRECIST). Results of histogram analysis and mean AP values of the tumor were compared between responders and non-responders. Receiver operating characteristics were calculated to determine the parameters’ ability to discriminate responders from non-responders.ResultsAccording to mRECIST, 8 patients (50 %) were responders and 8 (50 %) non-responders. Comparing responders and non-responders, the 50th and 75th percentile of AP derived from histogram analysis was significantly different [AP 43.8/54.3 vs. 27.6/34.3 mL min{sup −1} 100 mL{sup −1}); p < 0.05], while the mean AP of HCCs (43.5 vs. 27.9 mL min{sup −1} 100 mL{sup −1}; p > 0.05) was not. Further heterogeneity parameters from histogram analysis (skewness, coefficient of variation, and 25th percentile) did not differ between responders and non-responders (p > 0.05). If the cut-off for the 75th percentile was set to an AP of 37.5 mL min{sup −1} 100 mL{sup −1}, therapy response could be predicted with a sensitivity of 88 % (7/8) and specificity of 75 % (6/8).ConclusionVoxel-wise histogram analysis of pretreatment CT perfusion indicating tumor heterogeneity of HCC improves the pretreatment prediction of response to TARE.

  1. Devascularization of Head and Neck Paragangliomas by Direct Percutaneous Embolization

    International Nuclear Information System (INIS)

    Ozyer, Umut; Harman, Ali; Yildirim, Erkan; Aytekin, Cuneyt; Akay, Tankut Hakki; Boyvat, Fatih

    2010-01-01

    Preoperative transarterial embolization of head and neck paragangliomas using particulate agents has proven beneficial for decreasing intraoperative blood loss. However, the procedure is often incomplete owing to extensive vascular structure and arteriovenous shunts. We report our experience with embolization of these lesions by means of direct puncture and intratumoral injection of n-butyl cyanoacrylate (NBCA) or Onyx. Ten patients aged 32-82 years who were referred for preoperative embolization of seven carotid body tumors and three jugular paragangliomas were retrospectively analyzed. Intratumoral injections were primarily performed in four cases with multiple small-caliber arterial feeders and adjunctive to transarterial embolization in six cases with incomplete devascularization. Punctures were performed under ultrasound and injections were performed under roadmap fluoroscopic guidance. Detailed angiographies were performed before and after embolization procedures. Control angiograms showed complete or near-complete devascularization in all tumors. Three tumors with multiple small-caliber arterial feeders were treated with primary NBCA injections. One tumor necessitated transarterial embolization after primary injection of Onyx. Six tumors showed regional vascularization from the vasa vasorum or small-caliber branches of the external carotid artery following the transarterial approach. These regions were embolized with NBCA injections. No technical or clinical complications related to embolization procedures occurred. All except one of the tumors were surgically removed following embolization. In conclusion, preoperative devascularization with percutaneous direct injection of NBCA or Onyx is feasible, safe, and effective in head and neck paragangliomas with multiple small-caliber arterial feeders and in cases of incomplete devascularization following transarterial embolization.

  2. Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation

    International Nuclear Information System (INIS)

    Farago, Giuseppe; Caldiera, V.; Antozzi, C.; Bellino, A.; Innocenti, A.; Ciceri, E.

    2017-01-01

    Spinal dural arteriovenous fistulas (SDAVFs) are acquired diseases that represent the majority of all arteriovenous spinal shunts, leading to progressive and disabling myelopathy. Treatment is focused on accurately disconnecting the fistula point. We present our experience with the double-cone-beam CT fusion technique successfully applied to evaluate treatment results in a series of SDAVFs. Between November 2011 and December 2015 we performed double-DynaCT acquisition (pre- and post-embolisation) in 12 cases of SDAVF. A successful DynaCT fusion technique was only achieved in the group of patients with pre- and post-treatment images acquired at the same time as the treatment session, under general anaesthesia (4/12). DynaCT performed on different days proved to be inadequate for the automated fusion technique because of changes in the body position (8/12). A pre-treatment flat-panel cone-beam CT with contrast, at the time of diagnostic angiography, can be very helpful to detect the correct level of the fistula and the relationship between the fistula and the surrounding structures. In case of the endovascular approach, additional post-treatment native acquisition merged with the pre-treatment acquisition (double-cone-beam CT fusion technique) permits to immediately evaluate the distribution of the glue cast and to confirm the success of the procedure. (orig.)

  3. Automated double-cone-beam CT fusion technique. Enhanced evaluation of glue distribution in cases of spinal dural arteriovenous fistula (SDAVF) embolisation

    Energy Technology Data Exchange (ETDEWEB)

    Farago, Giuseppe [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Fondazione IRCCS Istituto Neurologico Carlo Besta, Department of Interventional Neuroradiology, Milan (Italy); Caldiera, V. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Antozzi, C.; Bellino, A. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Neuroimmunology and Neuromuscular Diseases, Milan (Italy); Innocenti, A. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Neuro-Oncology, Milan (Italy); Ciceri, E. [Foundation Neurological Institute ' ' C. Besta' ' , Department of Interventional Neuroradiology, Milan (Italy); Azienda Ospedaliera Universitaria Integrata Borgo Trento, Department of Neuroradiology, Verona (Italy)

    2017-05-15

    Spinal dural arteriovenous fistulas (SDAVFs) are acquired diseases that represent the majority of all arteriovenous spinal shunts, leading to progressive and disabling myelopathy. Treatment is focused on accurately disconnecting the fistula point. We present our experience with the double-cone-beam CT fusion technique successfully applied to evaluate treatment results in a series of SDAVFs. Between November 2011 and December 2015 we performed double-DynaCT acquisition (pre- and post-embolisation) in 12 cases of SDAVF. A successful DynaCT fusion technique was only achieved in the group of patients with pre- and post-treatment images acquired at the same time as the treatment session, under general anaesthesia (4/12). DynaCT performed on different days proved to be inadequate for the automated fusion technique because of changes in the body position (8/12). A pre-treatment flat-panel cone-beam CT with contrast, at the time of diagnostic angiography, can be very helpful to detect the correct level of the fistula and the relationship between the fistula and the surrounding structures. In case of the endovascular approach, additional post-treatment native acquisition merged with the pre-treatment acquisition (double-cone-beam CT fusion technique) permits to immediately evaluate the distribution of the glue cast and to confirm the success of the procedure. (orig.)

  4. A case grafted with polyglycolic acid sheets and fibrin glue for protection after temporary resection of a metastatic cervical skin tumor.

    Science.gov (United States)

    Matsuzuka, Takashi; Suzuki, Masahiro; Ikeda, Masakazu; Sato, Kaoru; Fujimoto, Junko; Hosaka, Rumi; Tanji, Yuko; Soeda, Shu; Murono, Shigeyuki

    2018-04-01

    The aim of this case report was to evaluate the usefulness of a grafting with polyglycolic acid sheet and a fibrin glue spray (PGA sheet grafting) after resection of a cervical skin tumor. A 61-year-old woman presented with left cervical skin tumor resistance to chemo-radiotherapy. She had been undergoing multimodal therapy for ovarian serous papillary adenocarcinoma for the previous six years. Although she had a poor general condition and a cervical skin tumor of 9cm in diameter, which was painful and easy bleeding, had offensive smell, she hoped to return to her job. Under local anesthesia, resection was performed, and PGA sheet grafting were used to shield the skin defect. After resection, she was relieved from pain, and could stay home without daily wound treatment. One and half months after resection, the wound was almost epithelialized. The PGA sheets consist of soft, elastic, nonwoven fabric made of PGA. In recent years, PGA sheet grafting has been widely used in the reconstruction and was chosen to shield the skin defect for this case. PGA sheet grafting after resection of cervical skin tumor can be an acceptable method for palliative care to relieve pain, bleeding, offensive smell, and ugly appearance. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Comparative study between fibrin glue and platelet rich plasma in dogs skin grafts Estudo comparativo entre a cola de fibrina e o plasma rico em plaquetas em enxertos cutâneos em cães

    Directory of Open Access Journals (Sweden)

    Larissa Correa Hermeto

    2012-11-01

    Full Text Available PURPOSE: Compare fibrin glue (Tissucol® and platelet-rich plasma in full-thickness mesh skin grafts in dogs. METHODS: Eighteen dogs were used, divided into two groups: fibrin glue (FG and platelet-rich plasma (PRP. In all the animals, a full-thickness 3x3 cm mesh skin graft was implanted. In the left limb, the biomaterial was place between the graft and the receptor bed, according to the group, while the right limb served as the control group. All the animals were evaluated clinically every 48 hours until the 14th day, using the variables of exudation, coloration, edema and cosmetic appearance. Three animals were evaluated histologically, on the third, seventh and tenth postoperative days, using the variables of fibroblasts, collagen, granulation tissue, microscopic integration-adherence and acute inflammation. RESULTS: Clinical evaluations showed that the group CF showed better scores for all variables compared to PRP group. On the histological evaluations PRP group had a higher presence of fibroblasts in the seventh and fourteenth days. CONCLUSION: The fibrin glue group was clinically superior to the platelet-rich group when used on full-thickness skin grafts in dogs.OBJETIVO: Comparar a cola de fibrina (Tissucol® e o plasma rico em plaquetas em enxertos cutâneos de espessura completa em malha em cães. MÉTODOS: Foram utilizados 18 cães, distribuídos em dois grupos, cola de fibrina (CF e plasma rico em plaquetas (PRP. Em todos os animais foi realizado um enxerto cutâneo de 3x3 cm, em malha de espessura completa. No membro esquerdo foi colocado o biomaterial entre o enxerto e o leito receptor, cada qual em seu grupo, o membro direito serviu como grupo controle. Todos os animais foram avaliados clinicamente a cada 48 horas até o décimo quarto dia, através das variáveis: exsudação, coloração, edema e aspecto cosmético; histologicamente em três animais, no terceiro, sétimo e décimo quarto dia de pós-operatório através das

  6. Fiber optic D dimer biosensor

    Science.gov (United States)

    Glass, Robert S.; Grant, Sheila A.

    1999-01-01

    A fiber optic sensor for D dimer (a fibrinolytic product) can be used in vivo (e.g., in catheter-based procedures) for the diagnosis and treatment of stroke-related conditions in humans. Stroke is the third leading cause of death in the United States. It has been estimated that strokes and stroke-related disorders cost Americans between $15-30 billion annually. Relatively recently, new medical procedures have been developed for the treatment of stroke. These endovascular procedures rely upon the use of microcatheters. These procedures could be facilitated with this sensor for D dimer integrated with a microcatheter for the diagnosis of clot type, and as an indicator of the effectiveness, or end-point of thrombolytic therapy.

  7. From Nano to Micro: Importance of Structure and Architecture in Spider Silk Adhesives

    Science.gov (United States)

    Sahni, Vasav; Dhinojwala, Ali

    2012-02-01

    Spiders have developed outstanding adhesives over millions of years of evolution for prey capture and locomotion. We show that the structure and architecture of these adhesives play an important role in the adhesion. The adhesive produced by orb-weaving spiders to capture prey (viscid glue) is laid on a pair of silk fibers as micron-size glue drops composed of salts and glycoproteins. By stretching single drops, we show that viscid glue behaves like a viscoelastic solid and that elasticity is critical in enhancing adhesion caused by specific adhesive ligands by over 100 times. Comparing viscid glue with gumfoot glue, the glue produced by cob-weavers, the evolutionary descendants of orb-weavers, showed that, in spite of being produced in homologous aggregate glands, gumfoot glue behaves like a viscoelastic liquid. Moreover, gumfoot glue is humidity-resistant and viscid glue is humidity-sensitive. We use a synthetic strategy to spin beads-on-a-string (BOAS) architecture to mimic the adhesive properties of spider silk. Using these mimic threads, we show that the BOAS structure adheres more than a cylindrical structure during contact (collision of prey) and during separation (escape attempt of prey). These results inspire design of novel tunable adhesives.

  8. ATLAS TileCal Sub-Module Production at UIUC - Production Submodule Photos (current)

    CERN Multimedia

    Errede, Steve

    2000-01-01

    Step 4: Stacking and Gluing. Photo 6 - This is the glue robot, it is what we use to stack and glue the modules. Photo 7 - This is the computer progam we use to make the glue dots precise on the spacers and plates. Photo 8 - The Glue Robot in action. .

  9. SU-F-T-630: Energy Spectral Study On Lipiodol After Trans-Arterial Chemoembolization Using the Flattened and Unflattened Photon Beams

    Energy Technology Data Exchange (ETDEWEB)

    Kawahara, D [Radiation Therapy Section, Department of Clinical Support, Hiroshima University Hospital, Hiroshima (Japan); Medical and Dental Sciences Course, Graduate School of Biomedical & Health Sciences, Hiroshima University, Hiroshima (Japan); Ozawa, S; Nagata, Y [Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University, Hiroshima (Japan); Hiroshima High-Precision Radiotherapy Cancer Center, Hiroshima (Japan); Saito, A; Nishio, T; Suzuki, T [Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University, Hiroshima (Japan); Hioki, K; Masuda, H; Okumura, T; Ochi, Y; Nakashima, T; Ohno, Y [Radiation Therapy Section, Department of Clinical Support, Hiroshima University Hospital, Hiroshima (Japan); Tanaka, S [Department of Nuclear Engineering and Management, School of Engineering, University of Tokyo, Tokyo (Japan)

    2016-06-15

    Purpose: SBRT combining transarterial chemoembolization with Lipiodol is expected to improve local control. Our showed that the dose enhancement effect in the Lipiodol with 10X flattening filter free (FFF) was inserted. This study was to investigate the energy fluence variations of electron in the Lipiodol using flattened (FF) and FFF beams. Methods: FF and FFF for 6X and 10X beams by TrueBeam were used in this study. The Lipiodol (3 X 3 X 3 cm{sup 3}) was located at the depth of 5 cm in water, the dose enhancement factor (DEF) and energy fluence were calculated by Monte Carlo (MC) calculations (PHITS). Results: DEFs with FF and FFF of 6X were 17.1% and 24.3% at rebuild-up region in the Lipiodol (5.3cm depth), 7.0% and 17.0% at the center of Lipiodol (6.5cm depth), and −13.2% and −8.2% at behind Lipiodol (8.3cm depth). DEFs with FF and FFF of 10X were 21.7% and 15.3% at rebuild-up region, 8.2% and 10.5% at the center of Lipiodol, and −14.0% and −8.6% at behind Lipiodol. Spectral results showed that the FFF beam contained more low-energy (0–0.3MeV) component of electrons than FF beam, and FF beam contained more high-energy (over 0.3MeV) electrons than FFF beam in Lipiodol. Behind the Lipiodol, build-down effect with FF beam was larger than FFF beam because FF beam contained more high energy electrons. The difference of DEFs between FFF and FF beams for 6X were larger than for 10X. This is because 10X beam contained more high-energy electrons. Conclusion: It was found that the 6XFFF beam gives the largest change of energy fluence and the largest DEF in this study. These phenomena are mainly caused by component of low-energy electrons, and this energy is almost correspond to the boundary of photo electronic dominant and Compton scattering dominant region for photon beams.

  10. The clinical study of interventional therapy of advanced and late staged carcinoma of digestive tract

    International Nuclear Information System (INIS)

    Liu Zengrong; Ren Shuiming; Luo Xiuzhen; Liu Fang; Liu Junxiang; Han Liping

    2003-01-01

    Objective: To evaluate the transarterial chemoembotherapy in the treatment of advanced or late staged digestive tract carcinoma. Methods: One hundred fifty-one patients with advanced or late staged digestive tract carcinoma (including 20 cases of esophageal carcinoma, 29 cases of cardia carcinoma, 71 cases of gastric carcinoma and 31 cases of large intestinal carcinoma) underwent super selective transarterial chemoembotherapy. Results: Interventions were successful. Symptoms were apparently improved in all cases. Decreased diameter of tumor was seen in all cases. Half-year survival rate was 95% (144/151); one year survival was 86% (130/150); two year survival rate was 66% (99/151); and three year survival rate was 29% (44/151). Conclusion: The transarterial chemoembotherapy is an effective treatment of advanced or late staged digestive tract carcinoma. In patients with metastases, the intervention is especially valuable for both primary and metastatic lesions

  11. IDENTIFICATION OF ANIMAL ADHESIVES USING DNA AMPLIFICATION

    DEFF Research Database (Denmark)

    Eriksen, Anne Marie; Kristensen, Hans Viborg; Bøllingtoft, Peder

    2014-01-01

    The aim of this study was to examine whether DNA was degraded in the manufacturing of animal glue. To test this, two different types of sturgeon glue (Acipenser sp.) were manufactured using historic recipes. One glue was boiled for a substantial amount of time and the other was kept under 75°C. DNA...... of the glue and in 18 out of 24 samples collected of the canvas. In four out of the five cases where it was not possible amplify DNA, the sample belongs to the smallest size of the canvas investigated. As shown in this study it is possible to get DNA out of boiled animal glue and glue applied onto canvas...

  12. Electrically conductive poly-ɛ-caprolactone/polyethylene glycol/multi-wall carbon nanotube nanocomposite scaffolds coated with fibrin glue for myocardial tissue engineering

    Science.gov (United States)

    Mehdikhani, Mehdi; Ghaziof, Sharareh

    2018-01-01

    In this research, poly-ɛ-caprolactone (PCL), polyethylene glycol (PEG), multi-wall carbon nanotubes (MWCNTs), and nanocomposite scaffolds containing 0.5 and 1% (w/w) MWCNTs coated with fibrin glue (FG) were prepared via solvent casting and freeze-drying technique for cardiac tissue engineering. Scanning electron microscopy, transmission electron microscopy, Fourier transform-infrared spectroscopy, and X-ray diffraction were used to characterize the samples. Furthermore, mechanical properties, electrical conductivity, degradation, contact angle, and cytotoxicity of the samples were evaluated. Results showed the uniform distribution of the MWCNTs with some aggregates in the prepared nanocomposite scaffolds. The scaffolds containing 1% (w/w) MWCNTs with and without FG coating illustrated optimum modulus of elasticity, high electrical conductivity, and wettability compared with PCL/PEG and PCL/PEG/0.5%(w/w) MWCNTs' scaffolds. FG coating enhanced electrical conductivity and cell response, and increased wettability of the constructs. The prepared scaffolds were degraded significantly after 60 days of immersion in PBS. Meanwhile, the nanocomposite containing 1% (w/w) MWCNTs with FG coating (S3) showed proper spreading and viability of the myoblasts seeded on it after 1, 4, and 7 days of culture. The scaffold containing 1% (w/w) MWCNTs with FG coating demonstrated optimal properties including acceptable mechanical properties, proper wettability, high electrical conductivity, satisfactory degradation, and excellent myoblasts response to it.

  13. Enhanced angiogenesis and osteogenesis in critical bone defects by the controlled release of BMP-2 and VEGF: implantation of electron beam melting-fabricated porous Ti6Al4V scaffolds incorporating growth factor-doped fibrin glue

    International Nuclear Information System (INIS)

    Lv, Jia; Xiu, Peng; Tan, Jie; Cai, Hong; Liu, Zhongjun; Jia, Zhaojun

    2015-01-01

    Electron beam melting (EBM)-fabricated porous titanium implants possessing low elastic moduli and tailored structures are promising biomaterials for orthopedic applications. However, the bio-inert nature of porous titanium makes reinforcement with growth factors (GFs) a promising method to enhance implant in vivo performance. Bone-morphogenic protein-2 (BMP-2) and vascular endothelial growth factor (VEGF) are key factors of angiogenesis and osteogenesis. Therefore, the present study is aimed at evaluating EBM-fabricated porous titanium implants incorporating GF-doped fibrin glue (FG) as composite scaffolds providing GFs for improvement of angiogenesis and osteogenesis in rabbit femoral condyle defects. BMP-2 and VEGF were added into the constituent compounds of FG, and then this GF-doped FG was subsequently injected into the porous scaffolds. In five groups of implants, angiogenesis and osteogenesis were evaluated at 4 weeks post-implantation using Microfil perfusion and histological analysis: eTi (empty scaffolds), cTi (containing undoped FG), BMP/cTi (containing 50 μg rhBMP-2), VEGF/cTi (containing 0.5 μg VEGF) and Dual/cTi (containing 50 μg rhBMP-2 and 0.5 μg VEGF). The results demonstrate that these composite implants are biocompatible and provide the desired gradual release of the bioactive growth factors. Incorporation of GF delivery, whether a single factor or dual factors, significantly enhanced both angiogenesis and osteogenesis inside the porous scaffolds. However, the synergistic effect of the dual factors combination was observable on angiogenesis but absent on osteogenesis. In conclusion, fibrin glue is a biocompatible material that could be employed as a delivery vehicle in EBM-fabricated porous titanium for controlled release of BMP-2 and VEGF. Application of this method for loading a porous titanium scaffold to incorporate growth factors is a convenient and promising strategy for improving osteogenesis of critical-sized bone defects

  14. Evaluation of variants in hepatic artery anatomy on conventional angiography in patients undergoing transarterial chemoembolization (tace): experience at siut

    International Nuclear Information System (INIS)

    Faiq, S.M.; Jesrani, A.; Jamal, M.; Lalwani, A.

    2017-01-01

    Objective: The purpose of this research is to evaluate common and uncommon variant of hepatic arterial anatomy that usually come across during Hepatic Angiographies. Study Design: Cross sectional study. Methods: This study included 50 patients having history of Hepatocellular Carcinoma from May to October 2015. Hepatic Angiography (Transarterial chemoembolization for management of Hepatoma and identification of classical and variant anatomy of hepatic artery) was evaluated in angiography unit. All procedures were performed on Digital Subtraction Angiography (DSA) machine (Toshiba KXO100 G). Selective DSA of the superior mesenteric artery and celiac trunk is performed initially to evaluate the frequency of normal and variant arterial anatomy and secondly to determine origin and course of tumor-feeding vessels. Evaluation of common and uncommon variants of hepatic arteries was done by using Michel’s classification as reference standard. Results: Age of the patient range from 40 – 80 years, 35 of whom were males. Fifty patients underwent angiographic procedure of viscera. Normal anatomy of hepatic artery was found in twenty eight (56%) cases. In six (12%) cases we found the replaced form of right hepatic artery (RHA) originating from visceral superior mesenteric artery. In five (10%) cases we found the replaced form of left hepatic artery (LHA) originating from left gastric artery (LGA), the combination of both these anomalies in one (2%) patient. Four (8%) cases had the left gastric artery giving rise to accessory left hepatic artery in conjunction with the common hepatic artery of celiac axis giving rise to typical right or left hepatic artery. In another four (8%) cases anatomic variation was noted in form of a dual arterial supply noted as common hepatic artery of celiac axis giving rise to typical left or right hepatic artery in conjunction with superior mesenteric artery giving rise to accessory right hepatic artery. In two (4%) cases superior mesenteric

  15. Feasibility of iFlow color-coding technique in quantitative real-time measurement of hemodynamic changes after transarterial chemoembolization for hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    WANG Yuzhe

    2018-01-01

    Full Text Available Objective To investigate the value of iFlow color-coding technique in quantitative real-time analysis of hemodynamic changes after transarterial chemoembolization (TACE for hepatocellular carcinoma (HCC. Methods A total of 31 patients who were diagnosed with HCC in Shanghai Fifth People′s Hospital from December 2015 to January 2017 were enrolled. No patient underwent surgical operation or ablation. All patients underwent TACE with the same contrast agent, high-pressure injector parameters, and place of angiographic catheter. The iFlow technique was used to generate two-dimensional color-coded images and time-density curve (TDC before and after surgery and measure the opening of the angiographic catheter and the time to peak (TTP of the starting and ending points of the major tumor feeding arteries, as well as the ratio of the areas under the curve (AUC of TDC of tumor tissue and the opening of the angiographic catheter. The paired t-test was used for comparison of continuous data between groups. Results TTP of the major tumor feeding arteries was 4.64±0.49 s before TACE and 5.97±0.84 s after TACE (t=11.57, P<0.01, and there was a significant difference in AUC between the tumor tissue and the opening of the angiographic catheter (0.53±0.15 vs 0.16±0.12, t=25.85, P<0.01. There was no significant difference in TTP between the opening of the angiographic catheter and the major tumor feeding arteries before and after TACE (P>0.05. Before TACE, the TDC of tumor feeding arteries had a shape of “rapid increase-rapid reduction” with relatively high slope and peak value, while after TACE, the TDC had a shape of “increase-flat-reduction” with reductions in slope and peak value. Conclusion The iFlow technique can perform real-time measurement of TTP and TDC of the region of interest and helps with quantitative evaluation of hemodynamic changes in HCC. Therefore, it can provide objective quantitative indices for evaluating the degree of

  16. Absorbed dose kernel and self-shielding calculations for a novel radiopaque glass microsphere for transarterial radioembolization.

    Science.gov (United States)

    Church, Cody; Mawko, George; Archambault, John Paul; Lewandowski, Robert; Liu, David; Kehoe, Sharon; Boyd, Daniel; Abraham, Robert; Syme, Alasdair

    2018-02-01

    Radiopaque microspheres may provide intraprocedural and postprocedural feedback during transarterial radioembolization (TARE). Furthermore, the potential to use higher resolution x-ray imaging techniques as opposed to nuclear medicine imaging suggests that significant improvements in the accuracy and precision of radiation dosimetry calculations could be realized for this type of therapy. This study investigates the absorbed dose kernel for novel radiopaque microspheres including contributions of both short and long-lived contaminant radionuclides while concurrently quantifying the self-shielding of the glass network. Monte Carlo simulations using EGSnrc were performed to determine the dose kernels for all monoenergetic electron emissions and all beta spectra for radionuclides reported in a neutron activation study of the microspheres. Simulations were benchmarked against an accepted 90 Y dose point kernel. Self-shielding was quantified for the microspheres by simulating an isotropically emitting, uniformly distributed source, in glass and in water. The ratio of the absorbed doses was scored as a function of distance from a microsphere. The absorbed dose kernel for the microspheres was calculated for (a) two bead formulations following (b) two different durations of neutron activation, at (c) various time points following activation. Self-shielding varies with time postremoval from the reactor. At early time points, it is less pronounced due to the higher energies of the emissions. It is on the order of 0.4-2.8% at a radial distance of 5.43 mm with increased size from 10 to 50 μm in diameter during the time that the microspheres would be administered to a patient. At long time points, self-shielding is more pronounced and can reach values in excess of 20% near the end of the range of the emissions. Absorbed dose kernels for 90 Y, 90m Y, 85m Sr, 85 Sr, 87m Sr, 89 Sr, 70 Ga, 72 Ga, and 31 Si are presented and used to determine an overall kernel for the

  17. Endovascular management of dural arteriovenous fistulas of the transverse and sigmoid sinus in 150 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kirsch, M [Ernst-Moritz-Arndt-Universitaet Greifswald, Institut fuer Diagnostische Radiologie und Neuroradiologie, Greifswald (Germany); Liebig, T [TU Muenchen, Institut fuer Neuroradiologie, Klinikum Rechts der Isar, Munich (Germany); Kuehne, D [Klinik fuer Radiologie und Neuroradiologie, Alfried-Krupp-Krankenhaus, Essen (Germany); Henkes, H [Katharinenhospital-Klinikum Stuttgart, Klinik fuer Neuroradiologie, Stuttgart (Germany)

    2009-07-15

    This study aimed to evaluate the safety and efficiency of the endovascular treatment of transverse-sigmoid sinus dural arteriovenous fistulas (TS{sub d}AVF). A total of 150 consecutive patients and 348 procedures were evaluated. Pulsatile tinnitus (81%), headache (15%), and intracranial hemorrhage (10%) were the most frequent manifestations of the TS{sub d}AVFs. More than half of the affected sinuses were partially or completely thrombosed. Access-wise treatment was performed transarterial (n = 33), transvenous (n = 21), or a combination thereof (n = 96). A mean of 2.4 procedures per patient was required. Immediate postprocedural occlusion rate after transarterial embolization was 30% only. Transvenous treatment alone resulted in an early occlusion rate of 81%, with delayed complete obliteration of half of the remaining fistulas. After combined transarterial/transvenous treatment, the angiographic cure rate was 54%. At follow-up, 88% of patients with residual shunt after the treatment showed complete occlusion. The cumulative complication rate was 9% (n = 13), with minor adverse events in ten patients (7%) and major complications in three patients (2%). Transvenous coil occlusion of the sinus segment with the adjacent dAVF site, eventually combined with transarterial occlusion of supplying arteries, is a very effective and well-tolerated treatment method. In selected patients, variations of these methods (e.g., sinus stenting, compartmental sinus occlusion) can be useful. (orig.)

  18. Endovascular management of dural arteriovenous fistulas of the transverse and sigmoid sinus in 150 patients

    International Nuclear Information System (INIS)

    Kirsch, M.; Liebig, T.; Kuehne, D.; Henkes, H.

    2009-01-01

    This study aimed to evaluate the safety and efficiency of the endovascular treatment of transverse-sigmoid sinus dural arteriovenous fistulas (TS d AVF). A total of 150 consecutive patients and 348 procedures were evaluated. Pulsatile tinnitus (81%), headache (15%), and intracranial hemorrhage (10%) were the most frequent manifestations of the TS d AVFs. More than half of the affected sinuses were partially or completely thrombosed. Access-wise treatment was performed transarterial (n = 33), transvenous (n = 21), or a combination thereof (n = 96). A mean of 2.4 procedures per patient was required. Immediate postprocedural occlusion rate after transarterial embolization was 30% only. Transvenous treatment alone resulted in an early occlusion rate of 81%, with delayed complete obliteration of half of the remaining fistulas. After combined transarterial/transvenous treatment, the angiographic cure rate was 54%. At follow-up, 88% of patients with residual shunt after the treatment showed complete occlusion. The cumulative complication rate was 9% (n = 13), with minor adverse events in ten patients (7%) and major complications in three patients (2%). Transvenous coil occlusion of the sinus segment with the adjacent dAVF site, eventually combined with transarterial occlusion of supplying arteries, is a very effective and well-tolerated treatment method. In selected patients, variations of these methods (e.g., sinus stenting, compartmental sinus occlusion) can be useful. (orig.)

  19. Ex-vivo release of Pipeline Embolization Device polytetrafluoroethylene (PTFE) sleeves for improved distal landing zone accuracy in-vivo: A technical note.

    Science.gov (United States)

    Griessenauer, Christoph J; Gupta, Raghav; Moore, Justin; Thomas, Ajith J; Ogilvy, Christopher S

    2016-12-01

    Distal landing zone accuracy is critical in some intracranial aneurysms treated with the Pipeline Embolization Device (PED), and delayed opening of the distal end of the device can complicate the procedure. Here, we report a technical nuance that facilitates accurate placement of the distal end of the PED by ex-vivo, pre-implantation release of the PED Flex polytetrafluoroethylene (PTFE) sleeves. The PED Flex is partially pushed out of the introducer sheath ex-vivo, pre-implantation until the distal PED opens entirely and the PTFE sleeves are located distal to the device. Without inverting the PTFE sleeves, the PED is carefully pulled back into the introducer sheath placing the PTFE sleeves inside the device. The PED is loaded into the microcatheter and advanced toward the site of implantation. When the PED is initially deployed and pushed out of the microcatheter, it opens immediately and provides an anchor for the remainder of the deployment process. We present a video (supplementary material) that illustrates the technique along with an illustrative case. Ex-vivo, pre-implantation release of the PTFE sleeves is an option in aneurysm treatment where distal landing accuracy is critical. Even without the protection of the PTFE sleeves, our clinical observation shows that the PED can be advanced safely through the microcatheter in selected cases. © The Author(s) 2016.

  20. The possibility and the countermeasure of the re-rupture within procedure in the embolization of intracranial aneurysms with Guglielmi detachable coils

    International Nuclear Information System (INIS)

    Li Minghua; Gu Binxian; Cheng Yingsheng; Fang Chun; Wang Wu; Xu Tao; Xu Shiding

    2004-01-01

    Objective: To study the possibility and the way to deal with the re-rupture within procedure for rupture aneurysms with Guglielmi detachable coil (GDC) embolization. Methods: When 159 cases with intracranial aneurysms were treated with GDC embolization, the rupture during procedure occurred in 7 cases. Of them, the re-rupture was related to microguidewire in one cases, related to coils in 3 cases, related to microcatheter in 2 cases, and related to over-packing with coils in one case. Results: A continuous packing with GDC with or without microcatheter adjustment, till a total occlusion of aneurysm, was performed in 3 cases with re-rupture related to coils and in 2 cases with re-rupture related to microcatheter. Of them, a complete recovery was acquired in 4 and a monoplegia remained in one case; Both the case with re-rupture related to microguidewire and the case with re-rupture related to over-packing with coils died due to intracerebral over-bleeding. Conclusion: It is unavoidable that the re-rupture occurred during the procedure of GDC embolization of intracranial aneurysms. Its occurrence is in inverse proportion with operator's experience. The proper choice of coils may reduce the occurrence of re-rupture related to procedure. A continuous packing with coils is possible to get a total occlusion without any sequels in re-ruptured aneurysms

  1. Pelvic artery embolization in gynecological bleeding

    International Nuclear Information System (INIS)

    Hausegger, K.A.; Schreyer, H.; Bodhal, H.

    2002-01-01

    The most common reasons for gynecological bleeding are pregnancy-related disorders, fibroids of the uterus, and gynecological malignances. Transarterial embolization is an effective treatment modality for gynecological bleeding regardless of its etiology. Depending on the underlying disease, a different technique of embolization is applied. In postpartal bleeding a temporary effect of embolization is desired, therefore gelatine sponge is used as embolizing agent. In fibroids and malignant tumors the effect should permanent, therefore PVA particles are used. Regardless the etiology, the technical and clinical success of transarterial embolization is at least 90%. In nearly every patient a post-embolization syndrome can be observed, represented by local pain and fever. This post-embolization syndrome usually does not last longer than 3 days. If embolization is performed with meticulous attention to angiographic technique and handling of embolic material, ischemic damage of adjacent organs is rarely observed. Transarterial embolization should be an integrative modality in the treatment of gynecological bleeding. (orig.) [de

  2. Does an Injection of Adipose-Derived Mesenchymal Stem Cells Loaded in Fibrin Glue Influence Rotator Cuff Repair Outcomes? A Clinical and Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Kim, Yong Sang; Sung, Chang Hun; Chung, Sung Hoon; Kwak, Sang Joon; Koh, Yong Gon

    2017-07-01

    The mesenchymal stem cell (MSC)-based tissue engineering approach has been developed to improve the treatment of rotator cuff tears. Hypothesis/Purpose: The purpose was to determine the effect of an injection of adipose-derived MSCs loaded in fibrin glue during arthroscopic rotator cuff repair on clinical outcomes and to evaluate its effect on structural integrity using magnetic resonance imaging (MRI). The hypothesis was that the application of adipose-derived MSCs would improve outcomes after the surgical repair of a rotator cuff tear. Cohort study; Level of evidence, 3. Among 182 patients treated with arthroscopic surgery for a rotator cuff tear, 35 patients treated with arthroscopic rotator cuff repair alone (conventional group) were matched with 35 patients who underwent arthroscopic rotator cuff repair with an injection of adipose-derived MSCs loaded in fibrin glue (injection group) based on sex, age, and lesion size. Outcomes were assessed with respect to the visual analog scale (VAS) for pain, range of motion (ROM) (including forward flexion, external rotation at the side, and internal rotation at the back), and functional measures of the Constant score and University of California, Los Angeles (UCLA) shoulder rating scale. Repaired tendon structural integrity was assessed by using MRI at a minimum of 12 months after surgery, and the mean clinical follow-up was 28.8 ± 4.2 months in the conventional group and 28.3 ± 3.8 months in the injection group. The mean VAS score at rest and during motion improved significantly in both groups after surgery. However, there were no significant differences between the groups at the final follow-up ( P = .256 and .776, respectively). Compared with preoperative measurements, forward flexion and external rotation at the side significantly improved at the final follow-up in both groups (all P rotation at the back were observed in either group ( P = .625 and .834 for the conventional and injection groups, respectively

  3. The value of [11C]-acetate PET and [18F]-FDG PET in hepatocellular carcinoma before and after treatment with transarterial chemoembolization and bevacizumab

    International Nuclear Information System (INIS)

    Li, Shuren; Ubl, Philipp; Wadsak, Wolfgang; Mitterhauser, Markus; Rainer, Eva; Haug, Alexander; Hacker, Marcus; Peck-Radosavljevic, Markus; Pinter, Matthias; Wang, Hao; Nanoff, Christian; Kaczirek, Klaus

    2017-01-01

    This prospective study was to investigate the value of [ 11 C]-acetate PET and [ 18 F]-FDG PET in the evaluation of hepatocellular carcinoma (HCC) before and after treatment with transarterial chemoembolization (TACE) and vascular endothelial growth factor (VEGF) antibody (bevacizumab). Twenty-two patients (three women, 19 men; 62 ± 8 years) with HCC verified by histopathology were treated with TACE and bevacizumab (n = 11) or placebo (n = 11). [ 11 C]-acetate PET and [ 18 F]-FDG PET were performed before and after TACE with bevacizumab or placebo. Comparisons between groups were performed with t-tests and Chi-squared tests, where appropriate. Overall survival (OS) was defined as the time from start of bevacizumab or placebo until the date of death/last follow-up, respectively. The patient-related sensitivity of [ 11 C]-acetate PET, [ 18 F]-FDG PET, and combined [ 11 C]-acetate and [ 18 F]-FDG PET was 68%, 45%, and 73%, respectively. There was a significantly higher rate of conversion from [ 11 C]-acetate positive lesions to negative lesions in patients treated with TACE and bevacizumab as compared with that in patients with TACE and placebo (p < 0.05). In patients with negative acetate PET, the mean OS in patients treated with TACE and bevacizumab was 259 ± 118 days and was markedly shorter as compared with that (668 ± 217 days) in patients treated with TACE and placebo (p < 0.05). In patients treated with TACE and placebo, there was significant difference in mean OS in patients with positive FDG PET as compared with that in patients with negative FDG PET (p < 0.05). The HCC lesions had different tracer avidities showing the heterogeneity of HCC. Our study suggests that combining [ 18 F]-FDG with [ 11 C]-acetate PET could be useful for the management of HCC patients and might also provide relevant prognostic and molecular heterogeneity information. (orig.)

  4. The value of [11C]-acetate PET and [18F]-FDG PET in hepatocellular carcinoma before and after treatment with transarterial chemoembolization and bevacizumab.

    Science.gov (United States)

    Li, Shuren; Peck-Radosavljevic, Markus; Ubl, Philipp; Wadsak, Wolfgang; Mitterhauser, Markus; Rainer, Eva; Pinter, Matthias; Wang, Hao; Nanoff, Christian; Kaczirek, Klaus; Haug, Alexander; Hacker, Marcus

    2017-09-01

    This prospective study was to investigate the value of [ 11 C]-acetate PET and [ 18 F]-FDG PET in the evaluation of hepatocellular carcinoma (HCC) before and after treatment with transarterial chemoembolization (TACE) and vascular endothelial growth factor (VEGF) antibody (bevacizumab). Twenty-two patients (three women, 19 men; 62 ± 8 years) with HCC verified by histopathology were treated with TACE and bevacizumab (n = 11) or placebo (n = 11). [ 11 C]-acetate PET and [ 18 F]-FDG PET were performed before and after TACE with bevacizumab or placebo. Comparisons between groups were performed with t-tests and Chi-squared tests, where appropriate. Overall survival (OS) was defined as the time from start of bevacizumab or placebo until the date of death/last follow-up, respectively. The patient-related sensitivity of [ 11 C]-acetate PET, [ 18 F]-FDG PET, and combined [ 11 C]-acetate and [ 18 F]-FDG PET was 68%, 45%, and 73%, respectively. There was a significantly higher rate of conversion from [ 11 C]-acetate positive lesions to negative lesions in patients treated with TACE and bevacizumab as compared with that in patients with TACE and placebo (p < 0.05). In patients with negative acetate PET, the mean OS in patients treated with TACE and bevacizumab was 259 ± 118 days and was markedly shorter as compared with that (668 ± 217 days) in patients treated with TACE and placebo (p < 0.05). In patients treated with TACE and placebo, there was significant difference in mean OS in patients with positive FDG PET as compared with that in patients with negative FDG PET (p < 0.05). The HCC lesions had different tracer avidities showing the heterogeneity of HCC. Our study suggests that combining [ 18 F]-FDG with [ 11 C]-acetate PET could be useful for the management of HCC patients and might also provide relevant prognostic and molecular heterogeneity information.

  5. Stabilization Improves Theranostic Properties of Lipiodol{sup ®}-Based Emulsion During Liver Trans-arterial Chemo-embolization in a VX2 Rabbit Model

    Energy Technology Data Exchange (ETDEWEB)

    Deschamps, F., E-mail: frederic.deschamps@gustaveroussy.fr; Farouil, G. [Université Paris-Saclay, Département de radiologie Interventionnelle, Gustave Roussy (France); Gonzalez, W.; Robic, C. [Guerbet France, Guerbet (France); Paci, A.; Mir, L. M. [Université Paris-Saclay, UMR 8203 (France); Tselikas, L.; Baère, T. de [Université Paris-Saclay, Département de radiologie Interventionnelle, Gustave Roussy (France)

    2017-06-15

    PurposeTo demonstrate that stability is a crucial parameter for theranostic properties of Lipiodol{sup ®}-based emulsions during liver trans-arterial chemo-embolization.Materials and MethodsWe compared the theranostic properties of two emulsions made of Lipiodol{sup ®} and doxorubicin in two successive animal experiments (One VX2 tumour implanted in the left liver lobe of 30 rabbits). Emulsion-1 reproduced one of the most common way of preparation (ratio of oil/water: 1/1), and emulsion-2 was designed to obtain a water-in-oil emulsion with enhanced stability (ratio of oil/water: 3/1, plus an emulsifier). The first animal experiment compared the tumour selectivity of the two emulsions: seven rabbits received left hepatic arterial infusion (HAI) of emulsion-1 and eight received HAI of emulsion-2. 3D-CBCT acquisitions were acquired after HAI of every 0.1 mL to measure the densities’ ratios between the tumours and the left liver lobes. The second animal experiment compared the plasmatic and tumour doxorubicin concentrations after HAI of 1.5 mg of doxorubicin administered either alone (n = 3) or in emulsion-1 (n = 6) or in emulsion-2 (n = 6).ResultsEmulsion-2 resulted in densities’ ratios between the tumours and the left liver lobes that were significantly higher compared to emulsion-1 (up to 0.4 mL infused). Plasmatic doxorubicin concentrations (at 5 min) were significantly lower after HAI of emulsion-2 (19.0 μg/L) than emulsion-1 (275.3 μg/L, p < 0.01) and doxorubicin alone (412.0 μg/L, p < 0.001), and tumour doxorubicin concentration (day-1) was significantly higher after HAI of emulsion-2 (20,957 ng/g) than in emulsion-1 (8093 ng/g, p < 0.05) and doxorubicin alone (2221 ng/g, p < 0.01).ConclusionStabilization of doxorubicin in a water-in-oil Lipiodol{sup ®}-based emulsion results in better theranostic properties.

  6. Robust cross-links in molluscan adhesive gels: testing for contributions from hydrophobic and electrostatic interactions.

    Science.gov (United States)

    Smith, A M; Robinson, T M; Salt, M D; Hamilton, K S; Silvia, B E; Blasiak, R

    2009-02-01

    The cross-linking interactions that provide cohesive strength to molluscan adhesive gels were investigated. Metal-based interactions have been shown to play an important role in the glue of the slug Arion subfuscus (Draparnaud), but other types of interactions may also contribute to the glue's strength and their role has not been investigated. This study shows that treatments that normally disrupt hydrophobic or electrostatic interactions have little to no effect on the slug glue. High salt concentrations and non-ionic detergent do not affect the solubility of the proteins in the glue or the ability of the glue proteins to stiffen gels. In contrast, metal chelation markedly disrupts the gel. Experiments with gel filtration chromatography identify a 40 kDa protein that is a central component of the cross-links in the glue. This 40 kDa protein forms robust macromolecular aggregations that are stable even in the presence of high concentrations of salt, non-ionic detergent, urea or metal chelators. Metal chelation during glue secretion, however, may block some of these cross-links. Such robust, non-specific interactions in an aqueous environment are highly unusual for hydrogels and reflect an intriguing cross-linking mechanism.

  7. {sup 18}F-FDG PET/CT predicts survival after {sup 90}Y transarterial radioembolization in unresectable hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Jreige, Mario; Mitsakis, Periklis; Gucht, Axel van der; Pomoni, Anastasia; Silva-Monteiro, Marina; Boubaker, Ariane; Nicod-Lalonde, Marie; Prior, John O.; Schaefer, Niklaus [Lausanne University Hospital, Department of Nuclear Medicine and Molecular Imaging, Lausanne (Switzerland); Gnesin, Silvano [Lausanne University Hospital, Institute of Radiation Physics, Lausanne (Switzerland); Duran, Rafael; Denys, Alban [Lausanne University Hospital, Department of Radiodiagnostic and Interventional Radiology, Lausanne (Switzerland)

    2017-07-15

    To compare the value of pretreatment functional and morphological imaging parameters for predicting survival in patients undergoing transarterial radioembolization using yttrium-90 ({sup 90}Y-TARE) for unresectable hepatocellular carcinoma (uHCC). We analysed data from 48 patients in our prospective database undergoing {sup 90}Y-TARE treatment for uHCC (31 resin, 17 glass). All patients underwent {sup 18}F-FDG PET/CT and morphological imaging (CT and MRI scans) as part of a pretherapeutic work-up. Patients did not receive any treatment between these imaging procedures and {sup 90}Y-TARE. Kaplan-Meier estimates of progression-free survival (PFS) and overall survival (OS) were used to assess the prognostic value of {sup 18}F-FDG PET/CT metabolic parameters, including SUV{sub max}, tumour-to-liver (T/L) uptake ratio and SUV{sub mean} of healthy liver, and morphological data, including number and size of lesions, portal-venous infiltration (PVI). Relevant prognostic factors for HCC including Child-Pugh class, Barcelona Clinic Liver Cancer (BCLC) stage, tumour size, PVI and serum AFP level were compared with metabolic parameters in univariate and multivariate analyses. The median follow-up in living patients was 16.2 months (range 11.4-50.1 months). Relapse occurred in 34 patients (70.8%) at a median of 7.4 months (range 1.4-27.9 months) after {sup 90}Y-TARE, and relapse occurred in 24 of 34 patients (70.8%) who died from their disease at a median of 8.1 months (range 2.2-35.2 months). Significant prognostic markers for PFS were the mean and median lesion SUV{sub max} (both P = 0.01; median PFS 10.2 vs. 7.4 months), and significant prognostic markers for OS were the first quarter (Q1) cut-off values for lesion SUV{sub max} and T/L uptake ratio (both P = 0.02; median OS 30.9 vs. 9 months). The multivariate analysis confirmed that lesion SUV{sub max} and T/L uptake ratio were independent negative predictors of PFS (hazard ratio, HR, 2.7, 95% CI 1.2-6.1, P = 0.02, for mean

  8. A Novel External Carotid Arterial Sheath System for Intra-arterial Infusion Chemotherapy of Head and Neck Cancer.

    Science.gov (United States)

    Ii, Noriko; Fuwa, Nobukazu; Toyomasu, Yutaka; Takada, Akinori; Nomura, Miwako; Kawamura, Tomoko; Sakuma, Hajime; Nomoto, Yoshihito

    2017-07-01

    The purpose of this study was to describe a novel system for treating advanced head and neck cancer consisting of an external carotid arterial sheath (ECAS) and a microcatheter to inject drugs retrogradely into multiple feeding arteries through the superficial temporal artery (STA). Four consecutive patients with head and neck cancer that had more than one feeding artery were enrolled in this study. The ECAS was made of polyurethane and surface-coated with heparin resin to prevent thrombus formation, allowing it to remain in place for a prolonged period of time. The ECAS was inserted through the STA, and its tip was placed between the maxillary artery and facial artery. The tumor-feeding arteries were selected using a hooked-shaped microcatheter through the ECAS. A total of 13 target arteries were selected in the four patients. The microcatheter inserted via the ECAS was used to catheterize ten arteries (five lingual arteries and five facial arteries). The remaining three lingual arteries were directly selected by the catheter without ECAS. All of the target arteries were able to be catheterized superselectively. The technical success rate was 100%. Vascular occlusion, which might have been caused by the ECAS, was observed in one patient. No neurologic toxicities occurred. This ECAS system is a new approach for retrograde superselective intra-arterial chemotherapy that covers the entire tumor with anticancer drugs. It has the potential to increase the effectiveness of therapy for advanced head and neck cancer. Level 4, Case Series.

  9. Three-dimensional printing spiders: back-and-forth glue application yields silk anchorages with high pull-off resistance under varying loading situations.

    Science.gov (United States)

    Wolff, Jonas O; Herberstein, Marie E

    2017-02-01

    The anchorage of structures is a crucial element of construction, both for humans and animals. Spiders use adhesive plaques to attach silk threads to substrates. Both biological and artificial adhesive structures usually have an optimal loading angle, and are prone to varying loading situations. Silk anchorages, however, must cope with loading in highly variable directions. Here we show that the detachment forces of thread anchorages of orb-web spiders are highly robust against pulling in different directions. This is gained by a two-step back-and-forth spinning pattern during the rapid production of the adhesive plaque, which shifts the thread insertion point towards the plaque centre and forms a flexible tree root-like network of branching fibres around the loading point. Using a morphometric approach and a tape-and-thread model we show that neither area, nor width of the plaque, but the shift of the loading point towards the plaque centre has the highest effect on pull-off resistance. This is explained by a circular propagation of the delamination crack with a low peeling angle. We further show that silken attachment discs are highly directional and adjusted to provide maximal performance in the upstream dragline. These results show that the way the glue is applied, crucially enhances the toughness of the anchorage without the need of additional material intake. This work is a starting point to study the evolution of tough and universal thread anchorages among spiders, and to develop bioinspired 'instant' anchorages of thread- and cable-like structures to a broad bandwidth of substrates. © 2017 The Author(s).

  10. Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.

    Science.gov (United States)

    Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz

    2015-06-01

    The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.

  11. Effect of postoperative adjuvant transarterial chemoembolization on postoperative survival of patients with liver cancer and related influencing factors for prognosis

    Directory of Open Access Journals (Sweden)

    XING Zhixiang

    2017-12-01

    Full Text Available ObjectiveTo investigate the effect of postoperative adjuvant transarterial chemoembolization (TACE on the survival of patients with hepatocellular carcinoma (HCC, as well as influencing factors for prognosis. MethodsA retrospective analysis was performed for the clinical data of 215 HCC patients who were admitted to Renmin Hospital of Wuhan University from January 2007 to December 2012. According to whether TACE was given after hepatectomy, these patients were divided into single group with 95 patients and combination group with 120 patients. A comparative analysis was performed for the two groups. The patients in the single group were given hepatectomy alone, and those in the combination group were given hepatectomy followed by TACE at one month after surgery. General status, treatment condition, and related clinical indices were recorded for both groups, and the two groups were compared in terms of the 1-, 3-, and 5-year survival rates and disease-free survival rates after surgery. The independent samples t-test was used for comparison of continuous data between groups, and the chi-square test was used for comparison of categorical data between groups. The Kaplan-Meier method was used for comparison of survival rates between groups, and univariate analysis and Cox multivariate regression analysis were used to investigate the influencing factors for prognosis after hepatectomy. ResultsIn the combination group, the 1-, 3-, and 5-year survival rates were 96.5%, 67.0%, and 51.0%, respectively, with a median survival time of 51 months; in the single group, the 1-, 3-, and 5-year survival rates were 84.0%,49.5%, and 36.5%, respectively, with a median survival time of 39 months; there was a significant difference in survival rates between the two groups (χ2=5.540, P=0.018. The 1-, 3-, and 5-year disease-free survival rates were 91.7%, 62.5%, and 37.5%, respectively, in the combination group and 84.0%, 42.1%, and 26.3%, respectively, in the single

  12. DNA glue

    DEFF Research Database (Denmark)

    Filichev, Vyacheslav V; Astakhova, Irina V.; Malakhov, Andrei D.

    2008-01-01

    Significant alterations in thermal stability of parallel DNA triplexes and antiparallel duplexes were observed upon changing the attachment of ethynylpyrenes from para to ortho in the structure of phenylmethylglycerol inserted as a bulge into DNA (TINA). Insertions of two ortho-TINAs as a pseudo...

  13. The value of [{sup 11}C]-acetate PET and [{sup 18}F]-FDG PET in hepatocellular carcinoma before and after treatment with transarterial chemoembolization and bevacizumab

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuren; Ubl, Philipp; Wadsak, Wolfgang; Mitterhauser, Markus; Rainer, Eva; Haug, Alexander; Hacker, Marcus [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna (Austria); Peck-Radosavljevic, Markus; Pinter, Matthias [Medical University of Vienna, Department of Internal Medicine III, Division of Gastroenterology and Hepatology, Vienna (Austria); Wang, Hao [Chinese Academy of Medical Sciences, Peking Union Medical College, Department of Nuclear Medicine, Peking Union Medical College Hospital, Beijing (China); Nanoff, Christian [Medical University of Vienna, Institute of Pharmacology, Vienna (Austria); Kaczirek, Klaus [Medical University of Vienna, Department of Surgery, Vienna (Austria)

    2017-09-15

    This prospective study was to investigate the value of [{sup 11}C]-acetate PET and [{sup 18}F]-FDG PET in the evaluation of hepatocellular carcinoma (HCC) before and after treatment with transarterial chemoembolization (TACE) and vascular endothelial growth factor (VEGF) antibody (bevacizumab). Twenty-two patients (three women, 19 men; 62 ± 8 years) with HCC verified by histopathology were treated with TACE and bevacizumab (n = 11) or placebo (n = 11). [{sup 11}C]-acetate PET and [{sup 18}F]-FDG PET were performed before and after TACE with bevacizumab or placebo. Comparisons between groups were performed with t-tests and Chi-squared tests, where appropriate. Overall survival (OS) was defined as the time from start of bevacizumab or placebo until the date of death/last follow-up, respectively. The patient-related sensitivity of [{sup 11}C]-acetate PET, [{sup 18}F]-FDG PET, and combined [{sup 11}C]-acetate and [{sup 18}F]-FDG PET was 68%, 45%, and 73%, respectively. There was a significantly higher rate of conversion from [{sup 11}C]-acetate positive lesions to negative lesions in patients treated with TACE and bevacizumab as compared with that in patients with TACE and placebo (p < 0.05). In patients with negative acetate PET, the mean OS in patients treated with TACE and bevacizumab was 259 ± 118 days and was markedly shorter as compared with that (668 ± 217 days) in patients treated with TACE and placebo (p < 0.05). In patients treated with TACE and placebo, there was significant difference in mean OS in patients with positive FDG PET as compared with that in patients with negative FDG PET (p < 0.05). The HCC lesions had different tracer avidities showing the heterogeneity of HCC. Our study suggests that combining [{sup 18}F]-FDG with [{sup 11}C]-acetate PET could be useful for the management of HCC patients and might also provide relevant prognostic and molecular heterogeneity information. (orig.)

  14. Occupational contact dermatitis caused by aniline epoxy resins in the aircraft industry.

    Science.gov (United States)

    Pesonen, Maria; Suuronen, Katri; Jolanki, Riitta; Aalto-Korte, Kristiina; Kuuliala, Outi; Henriks-Eckerman, Maj-Len; Valtanen, Ilona; Alanko, Kristiina

    2015-08-01

    Tetraglycidyl-4,4'-methylenedianiline (TGMDA) is an aniline epoxy resin used in, for example, resin systems of pre-impregnated composite materials (prepregs) of the aircraft industry. Allergic contact dermatitis caused by TGMDA in prepregs has been described previously. To report on 9 patients with occupational allergic contact dermatitis caused by TGMDA in epoxy glues used in helicopter assembly. The patients were examined with patch testing at the Finnish Institute of Occupational Health in 2004-2009. The first patient was diagnosed by testing both components of two epoxy glues from the workplace, and was also tested with glue ingredients, including TGMDA. The following patients were tested with the glues and TGMDA. The resin parts of the glues were analysed for their epoxy compounds, including TGMDA. All of the patients had a patch test reaction to one or both of the resin parts of the TGMDA-containing glues. Eight of them had a strong allergic reaction to TGMDA, and one had a doubtful reaction to TGMDA. Two of the patients also had an allergic reaction to triglycidyl-p-aminophenol (TGPAP), another aniline epoxy resin, which was not present in the TGMDA-containing glues. In aircraft industry workers with suspected occupational dermatitis, aniline epoxy resins should be considered and patch tested as possible contact allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Selective inferior petrosal sinus sampling without venous outflow diversion in the detection of a pituitary adenoma in Cushing's syndrome

    International Nuclear Information System (INIS)

    Andereggen, Lukas; Schroth, Gerhard; Gralla, Jan; Ozdoba, Christoph; Seiler, Rolf; Mariani, Luigi; Beck, Juergen; Widmer, Hans-Rudolf; Andres, Robert H.; Christ, Emanuel

    2012-01-01

    Conventional MRI may still be an inaccurate method for the non-invasive detection of a microadenoma in adrenocorticotropin (ACTH)-dependent Cushing's syndrome (CS). Bilateral inferior petrosal sinus sampling (BIPSS) with ovine corticotropin-releasing hormone (oCRH) stimulation is an invasive, but accurate, intervention in the diagnostic armamentarium surrounding CS. Until now, there is a continuous controversial debate regarding lateralization data in detecting a microadenoma. Using BIPSS, we evaluated whether a highly selective placement of microcatheters without diversion of venous outflow might improve detection of pituitary microadenoma. We performed BIPSS in 23 patients that met clinical and biochemical criteria of CS and with equivocal MRI findings. For BIPSS, the femoral veins were catheterized bilaterally with a 6-F catheter and the inferior petrosal sinus bilaterally with a 2.7-F microcatheter. A third catheter was placed in the right femoral vein. Blood samples were collected from each catheter to determine ACTH blood concentration before and after oCRH stimulation. In 21 patients, a central-to-peripheral ACTH gradient was found and the affected side determined. In 18 of 20 patients where transsphenoidal partial hypophysectomy was performed based on BIPSS findings, microadenoma was histologically confirmed. BIPSS had a sensitivity of 94% and a specificity of 67% after oCRH stimulation in detecting a microadenoma. Correct localization of the adenoma was achieved in all Cushing's disease patients. BIPSS remains the gold standard in the detection of a microadenoma in CS. Our findings show that the selective placement of microcatheters without venous outflow diversion might further enhance better recognition to localize the pituitary tumor. (orig.)

  16. Transcatheter Arterial Embolization of Nonvariceal Upper Gastrointestinal Bleeding with N-Butyl Cyanoacrylate

    International Nuclear Information System (INIS)

    Jae, Hwan Jun; Chung, Jin Wook; Jung, Ah Young; Lee, Whal; Park, Jae Hyung

    2007-01-01

    To evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with N-Butyl Cyanoacrylate (NBCA) for nonvariceal upper gastrointestinal bleeding. Between March 1999 and December 2002, TAE for nonvariceal upper gastrointestinal bleeding was performed in 93 patients. The endoscopic approach had failed or was discarded as an approach for control of bleeding in all study patients. Among the 93 patients NBCA was used as the primary embolic material for TAE in 32 patients (28 men, four women; mean age, 59.1 years). The indications for choosing NBCA as the embolic material were: inability to advance the microcatheter to the bleeding site and effective wedging of the microcatheter into the bleeding artery. TAE was performed using 1:1 1:3 mixtures of NBCA and iodized oil. The angiographic and clinical success rate, recurrent bleeding rate, procedure related complications and clinical outcomes were evaluated. The angiographic and clinical success rates were 100% and 91% (29/32), respectively. There were no serious ischemic complications. Recurrent bleeding occurred in three patients (9%) and they were managed with emergency surgery (n = 1) and with a successful second TAE (n = 2). Eighteen patients (56%) had a coagulopathy at the time of TAE and the clinical success rate in this group of patients was 83% (15/18). TAE with NBCA is a highly effective and safe treatment modality for nonvariceal upper gastrointestinal bleeding, especially when it is not possible to advance the microcatheter to the bleeding site and when the patient has a coagulopathy

  17. Transcatheter Arterial Embolization of Nonvariceal Upper Gastrointestinal Bleeding with N-Butyl Cyanoacrylate

    Energy Technology Data Exchange (ETDEWEB)

    Jae, Hwan Jun; Chung, Jin Wook; Jung, Ah Young; Lee, Whal; Park, Jae Hyung [Seoul National University Hospital, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2007-02-15

    To evaluate the clinical efficacy and safety of transcatheter arterial embolization (TAE) with N-Butyl Cyanoacrylate (NBCA) for nonvariceal upper gastrointestinal bleeding. Between March 1999 and December 2002, TAE for nonvariceal upper gastrointestinal bleeding was performed in 93 patients. The endoscopic approach had failed or was discarded as an approach for control of bleeding in all study patients. Among the 93 patients NBCA was used as the primary embolic material for TAE in 32 patients (28 men, four women; mean age, 59.1 years). The indications for choosing NBCA as the embolic material were: inability to advance the microcatheter to the bleeding site and effective wedging of the microcatheter into the bleeding artery. TAE was performed using 1:1 1:3 mixtures of NBCA and iodized oil. The angiographic and clinical success rate, recurrent bleeding rate, procedure related complications and clinical outcomes were evaluated. The angiographic and clinical success rates were 100% and 91% (29/32), respectively. There were no serious ischemic complications. Recurrent bleeding occurred in three patients (9%) and they were managed with emergency surgery (n = 1) and with a successful second TAE (n = 2). Eighteen patients (56%) had a coagulopathy at the time of TAE and the clinical success rate in this group of patients was 83% (15/18). TAE with NBCA is a highly effective and safe treatment modality for nonvariceal upper gastrointestinal bleeding, especially when it is not possible to advance the microcatheter to the bleeding site and when the patient has a coagulopathy.

  18. Magnetic catheter manipulation in the interventional MR imaging environment.

    Science.gov (United States)

    Wilson, Mark W; Martin, Alastair B; Lillaney, Prasheel; Losey, Aaron D; Yee, Erin J; Bernhardt, Anthony; Malba, Vincent; Evans, Lee; Sincic, Ryan; Saeed, Maythem; Arenson, Ronald L; Hetts, Steven W

    2013-06-01

    To evaluate deflection capability of a prototype endovascular catheter, which is remotely magnetically steerable, for use in the interventional magnetic resonance (MR) imaging environment. Copper coils were mounted on the tips of commercially available 2.3-3.0-F microcatheters. The coils were fabricated in a novel manner by plasma vapor deposition of a copper layer followed by laser lithography of the layer into coils. Orthogonal helical (ie, solenoid) and saddle-shaped (ie, Helmholtz) coils were mounted on a single catheter tip. Microcatheters were tested in water bath phantoms in a 1.5-T clinical MR scanner, with variable simultaneous currents applied to the coils. Catheter tip deflection was imaged in the axial plane by using a "real-time" steady-state free precession MR imaging sequence. Degree of deflection and catheter tip orientation were measured for each current application. The catheter tip was clearly visible in the longitudinal and axial planes. Magnetic field artifacts were visible when the orthogonal coils at the catheter tip were energized. Variable amounts of current applied to a single coil demonstrated consistent catheter deflection in all water bath experiments. Changing current polarity reversed the observed direction of deflection, whereas current applied to two different coils resulted in deflection represented by the composite vector of individual coil activations. Microcatheter navigation through the vascular phantom was successful through control of applied current to one or more coils. Controlled catheter deflection is possible with laser lithographed multiaxis coil-tipped catheters in the MR imaging environment. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  19. In search of low cost biological analysis: Wax or acrylic glue bonded paper microfluidic devices

    KAUST Repository

    Kodzius, Rimantas

    2011-01-22

    In this body of work we have been developing and characterizing paper based microfluidic fabrication technologies to produce low cost biological analysis. Specifically we investigated the performance of paper microfluidics that had been bonded using wax or acrylic glue, and characterized the affect of these and other microfluidic materials on the polymerase chain reaction (PCR). We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax or cyanoacrylate-based resin as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes. The hot-melt adhesive wax or simple cyanoacrylate-based resin can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate film, glass sheets, or metal plate. The wax bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by evacuating the channels of adhesive material in a hot-water. We applied the wax-paper based microfluidic chip to HeLa cell electroporation. Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein recombinant E. coli bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration. The chip bonded with cyanoacrylate-based resin was tested by measuring protein concentration and carrying out DNA capillary electrophoresis. To study the biocompatibility and applicability of our microfluidic chip fabrication technology, we tested the PCR compatibility of our chip materials along with various other common materials

  20. Abnormal uterine bleeding due to vascular abnormality caused by D and E : doppler sonography for diagnosis and transcatheter arterial embolization for treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Jo; Heo, Chan; Jung, Tae Gun; Kim, Gi Sung; Kwon, Hyeok Po; Lee, Sang Kwon; Kwon, Jung Hyeok [Dongkang Hospital, Ulsan (Korea, Republic of); Lee, Yeong Hwan [Taegu Catholic Univ. School of Medicine, Taegu (Korea, Republic of)

    1996-06-01

    We attempted to evaluate the usefulness of Doppler sonography in the diagnosis of uterine vascular abnormality caused by previous D and E, and to report that transarterial embolization is an excellent treatment modality. We analyzed gray-scale US, color/duplex Doppler US and angiographic findings in seven patients with radiologically proven uterine vascular abnormality. Two of the seven cases were pseudoaneurysms and five of the seven cases were AVMs. n one of the AVMS, two small pseudoaneurysms were combined. In all cases, transarterial embolizations using 3 mm coil or/and gelfoam particles were performed. Follow-up US studies, including color Doppler US, were performed. on color/duplex Doppler sonography, two cases of pseudoaneurysm showed blood pools with turbulent arterial flow, and five cases of AVM showed asymmetrically increased cascularity, with vailable high velocities composed of the pulsatile arterial flow, with a high diastolic component. on angiography, the former showed pseudoaneruysmal sacs, and the latter densely opacified vascular tangles. No more abnormal uterine bleeding was shown following transarterial embolization in all cases. Color/duplex Doppler sonography was valuable in the diagnosis or treatment of abnormal uterine bleeding caused by uterine vascular abnormality such as acquired AVM or pseudoaneruysm.