WorldWideScience

Sample records for traditional post-operative radiography

  1. Digital Radiography in Kenya today

    International Nuclear Information System (INIS)

    Omenta, E.N.

    2006-01-01

    Its nearly one year and a half since digital imaging/radiography was introduced in Kenya mainly in Nairobi. the technology is becoming an increasingly effective and acceptable modality of producing radiographs from the traditional conventional radiography in use to date. the digital radiography offers numerous advantages that have been noted for the short period over the conventional way. For instance radiographs are produced in real time (less than 3 minutes), by so doing the technology has eliminated the wait for the processing period. the radiation exposure to the patient under the radiological examination is reduced as much as 90% from the traditional conventional film taking. The cost, labour and record-keeping necessary to maintain a chemical processor and darkroom operations are as well eliminated. The cost of purchasing and disposing of film wastes/darkroom processing chemicals, which are environmentally hazardous, also become unnecessary.digital radiography technology makes the digital images comparable to other images on the screen at that instant making both the patient and the clinician easily access images when needed. digital receptors have also replaced the cassette containing intensifying screens and film that is used in conventional radiography

  2. Computed radiography in NDT application

    International Nuclear Information System (INIS)

    Deprins, Eric

    2004-01-01

    Computed Radiography, or digital radiography by use of reusable Storage Phosphor screens, offers a convenient and reliable way to replace film. In addition to the reduced cost on consumables, the return on investment of CR systems is strongly determined by savings in exposure time, processing times and archival times. But also intangible costs like plant shutdown, environment safety and longer usability of isotopes are increasingly important when considering replacing film by Storage Phosphor systems. But mote than in traditional radiography, the use of digital images is a trade-off between the speed and the required quality. Better image quality is obtained by longer exposure times, slower phosphor screens and higher scan resolutions. Therefore, different kinds of storage phosphor screens are needed in order to cover every application. Most operations have the data, associated with the tests to be performed, centrally stored in a database. Using a digital radiography system gives not only the advantages of the manipulation of digital images, but also the digital data that is associated with it. Smart methods to associate cassettes and Storage screens with exposed images enhance the workflow of the NDT processes, and avoid human error. Automated measurements tools increase the throughput in different kinds of operations. This paper gives an overview of the way certain operations have decided to replace film by Computed Radiography, and what the major benefits for them have been.

  3. Routine perinatal and paediatric post-mortem radiography: detection rates and implications for practice

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [NHS Foundation Trust, Department of Radiology Great Ormond Street Hospital for Children, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom); Calder, Alistair D. [NHS Foundation Trust, Department of Radiology Great Ormond Street Hospital for Children, London (United Kingdom); Kiho, Liina [Camelia Botnar Laboratories Great Ormond Street Hospital for Children, Department of Paediatric Pathology, London (United Kingdom); Taylor, Andrew M. [Great Ormond Street Hospital for Children, Cardiorespiratory Unit, London (United Kingdom); UCL Institute of Cardiovascular Science, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom); Sebire, Neil J. [Camelia Botnar Laboratories Great Ormond Street Hospital for Children, Department of Paediatric Pathology, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom)

    2014-03-15

    Routine perinatal and paediatric post-mortem plain radiography allows for the diagnosis and assessment of skeletal dysplasias, fractures and other bony abnormalities. The aim of this study was to review the diagnostic yield of this practice. We identified 1,027 cases performed in a single institution over a 21/2-year period, including babygrams (whole-body examinations) and full skeletal surveys. Images were reported prior to autopsy in all cases. Radiology findings were cross-referenced with the autopsy findings using an autopsy database. We scored each case from 0 to 4 according to the level of diagnostic usefulness. The overall abnormality rate was 126/1,027 (12.3%). There was a significantly higher rate of abnormality when a skeletal survey was performed (18%) rather than a babygram (10%; P < 0.01); 90% (665/739) of babygrams were normal. Of the 74 abnormal babygrams, we found 33 incidental non-contributory cases, 19 contributory, 20 diagnostic, and 2 false-positive cases. There were only 2 cases out of 739 (0.27%) in whom routine post-mortem imaging identified potentially significant abnormalities that would not have been detected if only selected imaging had been performed. A policy of performing selected, rather than routine, foetal post-mortem radiography could result in a significant cost saving. Routine post-mortem paediatric radiography in foetuses and neonates is neither diagnostically useful nor cost-effective. A more evidence-based, selective protocol should yield significant cost savings. (orig.)

  4. Routine perinatal and paediatric post-mortem radiography: detection rates and implications for practice

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Calder, Alistair D.; Kiho, Liina; Taylor, Andrew M.; Sebire, Neil J.

    2014-01-01

    Routine perinatal and paediatric post-mortem plain radiography allows for the diagnosis and assessment of skeletal dysplasias, fractures and other bony abnormalities. The aim of this study was to review the diagnostic yield of this practice. We identified 1,027 cases performed in a single institution over a 21/2-year period, including babygrams (whole-body examinations) and full skeletal surveys. Images were reported prior to autopsy in all cases. Radiology findings were cross-referenced with the autopsy findings using an autopsy database. We scored each case from 0 to 4 according to the level of diagnostic usefulness. The overall abnormality rate was 126/1,027 (12.3%). There was a significantly higher rate of abnormality when a skeletal survey was performed (18%) rather than a babygram (10%; P < 0.01); 90% (665/739) of babygrams were normal. Of the 74 abnormal babygrams, we found 33 incidental non-contributory cases, 19 contributory, 20 diagnostic, and 2 false-positive cases. There were only 2 cases out of 739 (0.27%) in whom routine post-mortem imaging identified potentially significant abnormalities that would not have been detected if only selected imaging had been performed. A policy of performing selected, rather than routine, foetal post-mortem radiography could result in a significant cost saving. Routine post-mortem paediatric radiography in foetuses and neonates is neither diagnostically useful nor cost-effective. A more evidence-based, selective protocol should yield significant cost savings. (orig.)

  5. Comparison of the quality of the chest film between digital radiography and conventional high kV radiography

    International Nuclear Information System (INIS)

    Zeng Qingsi; Cen Renli; Chen Ling; He Jianxun; Lin Hanfei

    2003-01-01

    Objective: To evaluate the quality and usefulness of direct digital radiography system in roentgenogram of chest in clinical practice. Methods: 1000 cases of chest roentgenograms with digital radiography and high kV conventional radiography were selected for analysis by 3 senior radiologists. Results: 1. With digital radiography system, the quality of chest film was assessed as grade A in 50.6%, grade B in 38.5%, grade C in 10.9%, and no waste film. 2. With conventional high kV radiography, the quality of chest film was assessed as grade A in 41.1%, grade B in 44.1%, grade C in 13.3%, and waste film in 1.5%. The direct digital radiography was statistically superior to the conventional high kV radiography. 3. The fine structure of the lungs could be revealed in 100.0% of chest roentgenogram with direct digital radiograph system, which was significantly higher than that acquired with the conventional high KV radiography (78.6%, P < 0.001). Conclusion: Direct digital radiography could provide the chest film with better quality than that with the conventional high kV radiography. The direct digital radiography system is easy to operate, fast in capturing imaging and could provide post-processing techniques, which will facilitate the accurate diagnosis of chest radiography

  6. [Optimization of digital chest radiography image post-processing in diagnosis of pneumoconiosis].

    Science.gov (United States)

    Sheng, Bing-yong; Mao, Ling; Zhou, Shao-wei; Shi, Jin

    2013-11-01

    To establish the optimal image post-processing parameters for digital chest radiography as preliminary research for introducing digital radiography (DR) to pneumoconiosis diagnosis in China. A total of 204 pneumoconiosis patients and 31 dust-exposed workers were enrolled as the subjects in this research. Film-screen radiography (FSR) and DR images were taken for all subjects. DR films were printed after raw images were processed and parameters were altered using DR workstation (GE Healthcare, U.S.A.). Image gradations, lung textures, and the imaging of thoracic vertebra were evaluated by pneumoconiosis experts, and the optimal post-processing parameters were selected. Optical density was measured for both DR films and FSR films. For the DR machine used in this research, the contrast adjustment (CA) and brightness adjustment (BA) were the main parameters that determine the brightness and gray levels of images. The optimal ranges for CA and BA were 115%∼120% and 160%∼165%, respectively. The quality of DR chest films would be optimized when tissue contrast was adjusted to a maximum of 0.15, edge to a minimum of 1, and both noise reduction and tissue equalization to0.The failure rate of chest DR (0.4%) was significantly lower than that of chest FSR (17%) (P image post-processing on DR machine purchased from GE Healthcare, the DR chest films can meet all requirements for the quality of chest X-ray films in the Chinese diagnostic criteria for pneumoconiosis.

  7. Receiver operating characteristic curve evaluation on computed radiography: an experimental study

    International Nuclear Information System (INIS)

    Yu Zixi; Wang Changyuan; Xu Yue; Xie Jindong; Zhang Menglong; Wang Jian

    2003-01-01

    Objective: To get the maximum information from computed radiography (CR) output images by changing post-processing parameters. Methods: Six experimental photos of polypropylene balls of 2.0 mm in diameter were taken by means of one time X-ray exposing on an imaging plate (IP) with different post-processing parameters including rotation amount (GA), gray gradation type (GT), rotation center (GC), shifting amount (GS), frequency rank (RN), frequency type (RT), and degree of enhancement (RE). 6 photos were viewed by three students and one radiologist on a 6000 lx illuminance viewbox. Receiver operating characteristic (ROC) curves were made by means of 5-value-differentiation method. Results: The largest mean area value (Az) below ROC curves of a low contrast experimental photo with post-processing parameters GA=1.0, GT=A, GC=1.6, GS=0.3, RN=4.0, RT=R and RE=3.0 was 0.96, and the maximum information was obtained. The smallest mean area value (Az) was 0.78 with changed post-processing parameters GA=0.8, GS=-0.2 and RE=0.5 while other parameters were not changed. The minimum information was obtained from this photo. Conclusion: In order to get the maximum information from a CR output image, the post-processing parameters should be suitably selected

  8. Complications of rotator cuff surgery—the role of post-operative imaging in patient care

    Science.gov (United States)

    Thakkar, R S; Thakkar, S C; Srikumaran, U; Fayad, L M

    2014-01-01

    When pain or disability occurs after rotator cuff surgery, post-operative imaging is frequently performed. Post-operative complications and expected post-operative imaging findings in the shoulder are presented, with a focus on MRI, MR arthrography (MRA) and CT arthrography. MR and CT techniques are available to reduce image degradation secondary to surgical distortions of native anatomy and implant-related artefacts and to define complications after rotator cuff surgery. A useful approach to image the shoulder after surgery is the standard radiography, followed by MRI/MRA for patients with low “metal presence” and CT for patients who have a higher metal presence. However, for the assessment of patients who have undergone surgery for rotator cuff injuries, imaging findings should always be correlated with the clinical presentation because post-operative imaging abnormalities do not necessarily correlate with symptoms. PMID:24734935

  9. 75 FR 27368 - Aerotest Operations, Inc., Aerotest Radiography and Research Reactor; Notice of Consideration of...

    Science.gov (United States)

    2010-05-14

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 50-228, NRC-2010-0178] Aerotest Operations, Inc., Aerotest Radiography and Research Reactor; Notice of Consideration of Approval of Transfer and Conforming... approving the indirect transfer of Facility Operating License No. R-98 for the Aerotest Radiography and...

  10. Assessment of panoramic radiography as a national oral examination tool: review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2011-03-15

    The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. This report was carried out by review of the literatures. Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Panoramic radiography will improve the efficacy of dental examination in national oral examination. However, more studies are required to evaluate the benefit, financial cost, and operation time and also to make selection criteria and quality management program.

  11. 75 FR 57080 - In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order...

    Science.gov (United States)

    2010-09-17

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0178; Docket No. 50-228; License No. R-98] In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order Extending the... possession, use, and operation of the Aerotest Radiography and Research Reactor (ARRR) located in San Ramon...

  12. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  13. Post-modern career assessment for traditionally disadvantaged ...

    African Journals Online (AJOL)

    Post-modern career assessment for traditionally disadvantaged South African learners: Moving away from the 'expert opinion' ... Perspectives in Education ... This article explores the perceptions of learners from a disadvantaged community regarding the limitations and advantages of traditional and post-modern career ...

  14. Digital luminescent radiography: A substitute for conventional chest radiography?

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Krug, B.; Lorenz, R.; Steinbrich, W.

    1990-01-01

    The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a consequence, DLR is presently not in a position to replace traditional film-screen radiography of the chest completely. (orig.) [de

  15. 75 FR 39985 - In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order...

    Science.gov (United States)

    2010-07-13

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0178; Docket No. 50-228; License No. R-98] In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order Approving Indirect... of the Aerotest Radiography and Research Reactor (ARRR) located in San Ramon, California, under the...

  16. Post-secular religious practices entering traditional religion

    Directory of Open Access Journals (Sweden)

    Urszula Pękala

    2012-01-01

    Full Text Available Nowadays we can observe complex interactions between the religious and secular spheres. Several different processes take place simultaneously: the traditionally religious elements function in the secular sphere as if they were part of secular culture; elements of the secular sphere build a specific kind of post-secular religiosity; finally, this post-secular religiosity influences traditional religions. This article focuses on the last stage of these changes. The author's purpose is to describe and interpret the practices we can observe. Because of the complexity of this issue, the analyses are limited to examples taken from the Catholic Church in Germany, where this process seems to be as popular as it is paradoxical. Catholicism realises that the post-secular forms of religiosity are very popular and that many people choose them instead of the traditional Church. It could offer them spirituality based on ages of experience. But instead of making its own spiritual tradition competitive on the spiritual market, Catholicism seems to offer Christianised post-secular goods, or its own traditional elements represented in a secularised form. It seems difficult to predict how it will all end. However, we observe an interesting encounter and interaction between an ‘old’ religion and a new religiosity, which will certainly have impact on further presence of the Church in the society.

  17. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    Energy Technology Data Exchange (ETDEWEB)

    Radebe, M.J.; De Beer, F.C. [Necsa - South African Nuclear Energy Corporation Limited, P. O.Box 582, Pretoria, 0001 (South Africa)

    2008-07-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  18. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    International Nuclear Information System (INIS)

    Radebe, M.J.; De Beer, F.C.

    2008-01-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  19. Photon-counting digital radiography using high-pressure xenon filled detectors

    CERN Document Server

    Li, Maozhen; Johns, P C

    2001-01-01

    Digital radiography overcomes many of the limitations of the traditional screen/film system. Further enhancements in the digital radiography image are possible if the X-ray image receptor could measure the energy of individual photons instead of simply integrating their energy, as is the case at present. A prototype photon counting scanned projection radiography system has been constructed, which combines a Gas Electron Multiplier (GEM) and a Gas Microstrip Detector (GMD) using Xe : CH sub 4 (90 : 10) at high pressure. With the gain contribution from the GEM, the GMD can be operated at lower and safer voltages making the imaging system more reliable. Good energy resolution, and spatial resolution comparable to that of screen/film, have been demonstrated for the GEM/GMD hybrid imaging system in photon counting mode for X-ray spectra up to 50 kV.

  20. Operative outcomes of conventional specimen radiography versus in-operating room specimen radiography in radioactive seed-localized segmental mastectomies.

    Science.gov (United States)

    Rhee, Daniel; Pockaj, Barbara; Wasif, Nabil; Stucky, Chee-Chee; Pizzitola, Victor; Giurescu, Marina; Patel, Bhavika; McCarthy, Janice; Gray, Richard

    2018-01-01

    In-operating room specimen radiography (ORSR) has not been studied among women undergoing radioactive seed localization (RSL) for breast cancer surgery and had the potential to decrease operative time and perhaps improve intraoperative margin management. One hundred consecutive RSL segmental mastectomies among 98 patients using ORSR were compared to 100 consecutive segmental mastectomies among 98 patients utilizing conventional radiography (CSR) prior to the initiation of ORSR from December 2013 to January 2015 after radioactive seed localization. Final pathologic margins were considered to be 10 mm for all cases of no residual disease after biopsy or neoadjuvant therapy, but such patients were excluded from analyses involving tumor size. All patients' specimens were subjected to intraoperative pathologic consultation in addition to ORSR or CSR. The median age of the cohort was 65 years (range 36-97), and the median tumor size was 1 cm. There were no differences between the ORSR and CSR groups in age, tumor size, percentage of cases with only DCIS, and percentage of cases with microcalcifications. The ORSR group had a statistically significant lower BMI. Mean operative time from cut-to-close was not significantly different (ORSR 77 min, SD 24.8 vs CSR 76 min, SD 24.8, p = 0.75). There was no statistical difference in mean closest final pathologic margin (4.99 mm, SD 3.3 vs 4.88 mm, SD 3.5, p = 0.9). The percentage undergoing intraoperative margin re-excision (ORSR 40%, CR 47%, p = 0.31) and the mean total number of margins excised intraoperatively (ORSR 0.9, CR 1.0 p = 0.65) were similar. The rate of any margin CSR; this difference was not statistically significant (p = 0.25). The mean ratio of segmental mastectomy volume to maximum tumor diameter was less for ORSR (82.7cm2 vs 139.4cm2, p = 0.014). ORSR for RSL breast surgery, in the setting of routine intraoperative pathology consultation, does not significantly impact operative time, the rate or

  1. Need for New Optimisation Strategies in CR and Direct Digital Radiography

    International Nuclear Information System (INIS)

    Busch, H.P.

    2000-01-01

    Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, digital subtraction radiography and to fluoroscopy. Further work should lead to a definition of reference values for the dose and the image quality. This has to be done first for single exposures and fluoroscopic mode and secondly for diagnostic and interventional procedures. (author)

  2. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    International Nuclear Information System (INIS)

    Meade, W.; Kidwell, C.; Warren, G.

    2004-01-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  3. Inspection reliability comparison of digital radiography, film radiography and radioscopy for inspection of Inconel welds

    Energy Technology Data Exchange (ETDEWEB)

    Meade, W.; Kidwell, C.; Warren, G. [Boeing Commercial Aircraft Group, Renton, Washington (United States)

    2004-07-01

    Digital Radiography offers the promise of economic and environmental advantages over traditional film based inspection. Boeing Commercial Aircraft Group has an on-going effort to evaluate this emerging radiographic method for production of aerospace hardware. Included in this effort was a program to evaluate the potential for utilizing amorphous silicon based digital radiography for the inspection of inconel weldments in engine ducting. For this particular program, probability of detection (POD) studies were conducted to compare the reliability of digital radiography with the existing production processes that utilize film radiography and image-intensifier based radioscopy. Cycle time studies were also conducted to determine the potential economic benefit for switching to the new process. The methodology and findings of this comparison are presented. (author)

  4. Digital Radiography Qualification of Tube Welding

    Science.gov (United States)

    Carl, Chad

    2012-01-01

    The Orion Project will be directing Lockheed Martin to perform orbital arc welding on commodities metallic tubing as part of the Multi Purpose Crew Vehicle assembly and integration process in the Operations and Checkout High bay at Kennedy Space Center. The current method of nondestructive evaluation is utilizing traditional film based x-rays. Due to the high number of welds that are necessary to join the commodities tubing (approx 470), a more efficient and expeditious method of nondestructive evaluation is desired. Digital radiography will be qualified as part of a broader NNWG project scope.

  5. Assessment and prevention of the professional risks in the operations of industrial radiography

    International Nuclear Information System (INIS)

    Pizzorno, M.; Paul, D.; Coletti, F.; Sari Minodier, I.; Azzopardi, G.; Klemenic, O.; Botta, A.

    2006-01-01

    Industrial radiography is a nocturnal activity, hazardous and little known; it is among the professions the most exposed to ionizing radiation. This study analyse the doses, received the industrial radiographers, their workplace conditions and organization of their tasks. Dosimetry observations on site, together with calculations using the Mercurad code, allowed mean values for reference doses for all the work (including transport, gammatron manipulation, collimator manipulation, shooting) to be established. These value were integrated into a table entitled 'reference doses' in order to provisionally evaluate the doses received by the operators. Distances for security zone demarcation, so as to forbid access to non exposed personnel during shooting, were evaluated. Assessment of the professional risks for industrial radiography, taking into account all the risks (radiological and others), has been made and is under evaluation. This led to measures for prevention based on the material used (collimator, tripod, gamma-stops), on the organization and the conditions of work (for example, time limits permitting a prior visit to the site and preparation for radiography, suitable scaffolding, sufficient lighting, siting of shootings). These prevention measure will be integrated into the new charter of good practice in industrial radiography in the Provence Alpes Cote d'Azur region (south of France). (authors)

  6. Radiation Effects in Paediatric radiography

    International Nuclear Information System (INIS)

    Mutwasi, O.

    2006-01-01

    Diagnostic imaging has evolved from single technique to a field which we have a choice from many modalities. Some without radiation. Radiation producing modalities include plain films (low dose), Fluoroscopy (mid range dose), Computed tomography (high dose). Radiography dose can significantly be influenced in plain radiography by varying speed of screens, cassette construction and type of radiography. E.g. digital or computed. In computed or digital radiography we are no longer able to tell h igh dose b y the quality of images. The final image is by great extend a product of post processing algorithms. It's for this reasons that the basic understanding of the sensitivity and specifying of various types of examinations and of specifically radiation effects is mandatory for a paediatric imager

  7. Comparison of the incidence of patient-reported post-operative dysphagia between ACDF with a traditional anterior plate and artificial cervical disc replacement.

    Science.gov (United States)

    Yang, Yi; Ma, Litai; Liu, Hao; Liu, Yilian; Hong, Ying; Wang, Beiyu; Ding, Chen; Deng, Yuxiao; Song, Yueming; Liu, Limin

    2016-09-01

    Compared with anterior cervical discectomy and fusion (ACDF), cervical disc replacement (CDR) has provided satisfactory clinical results. The incidence of post-operative dysphagia between ACDF with a traditional anterior plate and CDR remains controversial. Considering the limited studies and knowledge in this area, a retrospective study focusing on post-operative dysphagia was conducted. The Bazaz grading system was used to assess the severity of dysphagia at post-operative intervals including 1 week, 1 month, 3 months, 6 months, 12 months and 24 months respectively. The Chi-square test, Student t-test, Mann-Whitney U tests and Ordinal Logistic regression were used for data analysis when appropriate. Statistical significance was accepted at a probability value of dysphagia in the CDR and plate group were 36.58% and 60.43% at one week, 29.27% and 38.85% at one month, 21.95% and 31.65% at three months, 6.83% and 17.99% at six months, 5.85% and 14.39% at 12 months, and 4.39% and 10.07% at the final follow-up respectively (All Pdysphagia (all Pdysphagia. Female patients, two-level surgery, C4/5 surgery and anterior cervical plating were associated with a higher incidence of dysphagia. Future prospective, randomized, controlled studies are needed to further validate these findings. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. The Post-traditional Chef in Traditional France: Negotiating the Gastronational myth in Le chef en France

    DEFF Research Database (Denmark)

    Leer, Jonatan

    – very often with a distinct focus on the margins of these countries- and valorising the exoticism in the proximity. In these shows there is often uphold another kind of modern-premodern dichotomy not between white and darker cultures, but between the urban, post-traditional culture (incorporated...... by the host) and the traditional pastoral culture in which archaic modes of being and living still exists. In the programs we often see a negotiation between the post-traditional and the traditional culture that often try to underline the entanglement and the interdependency of the two worlds in the national...

  9. Neutron radiography at the Risoe National Laboratory

    International Nuclear Information System (INIS)

    Domanus, J.C.; Gade-Nielsen, P.; Knudsen, P.; Olsen, J.

    1981-11-01

    In this report six papers are collected which will be presented at the First World Conference on Neutron Radiography in San Diego, U.S.A., 7 - 10 December 1981. They are preceded by a short description of the activities of Risoe National Laboratory in the field of post-irradiation examination of nuclear fuel. One of the nondestructive methods used for this examination is neutron radiography. In the six conference papers different aspects of neutron radiography performed at Risoe are presented. (author)

  10. Diagnostic approach to reflex sympathetic dystrophy after fracture: radiography or bone scintigraphy?

    International Nuclear Information System (INIS)

    Todorovic-Tirnanic, M.; Obradovic, V.; Han, R.; Goldner, B.; Stankovic, D.; Sekulic, D.; Lazic, T.; Djordjevic, B.

    1995-01-01

    The aim of this paper was to compare the value of bone scintigraphy and radiography in the early diagnosis of post-fracture reflex sympathetic dystrophy (RSD). Thirty-seven adult patients with post-fracture RSD (28 in the first and nine in the second clinical stage of RSD), as well as seven patients with fracture but without RSD (control group), were investigated by radiography and bone scintigraphy. All of them were immobilized (duration of immobilization: 4-22 weeks). In 21 persons three phase bone scintigraphy was performed. The best distinction between the control group and the RSD patients was achieved by delayed bone scintigrams. The sensitivity (97%), positive predictive value (97%) and accuracy (95%) of delayed bone scintigraphy were very high compared to the values for radiography, which were 73%, 90% and 70% respectively. Bone scintigraphy also displayed higher specificity (86%) and negative predictive value (86%) than radiography (57% and 29% respectively). In the first clinical stage the difference between the accuracy of bone scintigraphy (97%) and radiography (63%) was greater than for the whole group. In the second stage of RSD the accuracy of bone scintigraphy (86%) and radiography (81%) was similar. Three-phase bone scintigraphy is not necessary for the diagnosis of post-fracture RSD: it is sufficient to perform delayed bone scintigraphy. It is concluded that bone scintigraphy is to be preferred to radiography for the early diagnosis of post-fracture RSD in the first clinical stage. In the second stage the diagnostic capabilities of bone scintigraphy and radiography are more comparable. (orig.)

  11. Digital radiography is promising in industrial testing

    International Nuclear Information System (INIS)

    Del Fabbro, F.

    2015-01-01

    Digital radiography has recently entered the industrial world as a tool for non-destructive testing. There are 3 types of digital radiography: computed radiography (CR), direct radiography (DR) and computed tomography (CT). In computed radiography, traditional silver-halide films are replaced by photostimulable phosphor imaging plates that are activated through laser scanning and digitized. Direct radiography uses a flat panel detector (FPD) composed of X-ray detectors that performs an immediate digital conversion of the image that can be read by a computer. DR is a perfect tool for industrial testing but the fragility of the FPD panels reduces its uses. Computed tomography is based on the principle of DR to get data corresponding to successive cross-section images of the object. These data are processed by a software to get a 3-dimensional image of the object. CT was first developed for medical use but requires some improvement to become more accurate, faster, particularly for big objects. In recent years DR has enjoyed the highest growth rate in digital radiography. (A.C.)

  12. Some malpractices in application of computed radiography

    International Nuclear Information System (INIS)

    Liu Ruihong; Jia Shaotian; Wang Yusheng; Li Baohua; Chen Lin; Wang Zhenguang; Liu Jianxin; Gong Jingyue; Liu Daoyong; Xie Xuesong

    2007-01-01

    Objective: To improve the CR image quality and to promote the digital image standard constitution by analyzing the common problems and malpractices in application of computed radiography. Methods: Phenomenon and reasons of 107 CR junk-films from nine three-'A'-hospitals were analyzed, discussed, recorded, and statistised by 20 radiologists, radiographers and engineers. Results: Among 107 junk films, there are 36 cases (33.64%) of incorrect operations, 29 cases (27.10%) of artifacts in reading and transferring the data of IP, 15 cases (14.02%) of artifacts in IP system, and 13 cases (12.15%) of selection of inappropriate radiographic parameters, and 9 cases (8.41%) of printer-failures, and 5 cases (4.67%) of inappropriate post-processing techniques. By analyzing the reasons of 107 junk films we found that 60.74% were due to less responsibilities and incorrect operations, and 35.51% were due to new problems in CR techniques, and other were due to inappropriate post-processing techniques. Conclusion: Responsibilities, operation regulations, digital image quality standards, studying of new techniques and appropriate use of the post-processing techniques are the key points for improving the CR image quality and the diagnosis level. (authors)

  13. The advantages of digital radiography in department of radiology

    International Nuclear Information System (INIS)

    Mao Lijuan; Luo Xiaomei; Wu Tengfang

    2009-01-01

    Objective: To investigate the advantages of digital radiography in department of radiology by comparing digital radiography with common radiography. Methods: Test card was used for testing the spatial resolution of DR and common radiography. 1000 films of chest by DR and 1000 films of chest by common radiography were compared in image quality, dose of radiation, the rate of waste film, and the advantages of DR was analyzed. Results: Compared to common radiography, DR had a high sensitivity, high DQE (quantum detection efficiency), high spatial resolution and density resolution. The speed of acquisition and X-ray conversion efficiency were fast. The function of post-processing was strong and the rate of disease detection was high. Conclusion: DR is better than common radiography in all respects, it will be widely applied. (authors)

  14. Computer radiography - indirect digital radiography

    International Nuclear Information System (INIS)

    Jezierski, G.

    2008-01-01

    Implementation of the new European standards for industrial radiography with the use of storage phosphor imaging plates will result in the arousing of interest among numerous laboratories in non-destructive testing with application of the new method of testing to replace conventional radiography used so far, i.e. film radiography. Computer radiography is quite commonly used for medical radiography, where the fundamental problem consists in reduction of the radiation dose during the examination of a patient. However, it must be kept in mind that industrial applications have a little bit different requirements when compared with medical radiography. The article describes only new method for radiographic testing. (author)

  15. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    Energy Technology Data Exchange (ETDEWEB)

    Calder, Alistair D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Radiology Department, London (United Kingdom); Offiah, Amaka C. [Sheffield Children' s NHS Foundation Trust, Academic Unit of Child Health, Sheffield (United Kingdom)

    2015-04-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  16. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    International Nuclear Information System (INIS)

    Calder, Alistair D.; Offiah, Amaka C.

    2015-01-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  17. Charter of good practices in industrial radiography; Charte de bonnes pratiques en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  18. Portable radiography using linear accelerators

    International Nuclear Information System (INIS)

    Reid, D.W.

    1984-01-01

    There are numerous instances where the availability of a portable high-energy radiography machine that could be transported to the inspection site with relative ease would save time, money, and make radiography of permanent installations, such as bridges, possible. One such machine, the Minac built by Schoenberg Radiation Inc., is commercially available. It operates at 9.3 GHz, has an electron energy on target of 3.5 MeV, and an output dose rate of 100 R/min. A second portable accelerator, recently completed at the Los Alamos National Laboratory, operates at 2.998 GHz, has electron energies on target of 6, 8, and 10 MeV, and an output dose rate of 800 R/min at 8 MeV. This paper discusses the need for and applications of portable accelerators for radiography. Physical characteristics and beam parameters of both machines are examined in detail. Problems of operating at higher frequencies to further minimize size and weight are discussed

  19. The sensitivity of radiography of the postoperative stomach

    International Nuclear Information System (INIS)

    Ott, D.J.; Munitz, H.A.; Gelfand, D.W.; Lane, T.G.; Wu, W.C.

    1982-01-01

    The results of radiology and endoscopy were compared in 140 patients who had undergone gastric surgery for ulcer disease. Of 74 patients who were examined with single-contrast radiography, 37 had abnormalities that were demonstrated endoscopically. The radiographic sensitivities in these patients were: gastritis 2/22 (9%); ulcer 3/5 (60%); obstruction 8/8 (100%); and miscellaneous abnormalities 2/2 (100%). The predictive accuracy of a diagnois of ulcer was 38%. Of the 66 patients who were examined with double-contrast radiography, 33 abnormalities were found with endoscopy. The radiographic sensitivities were: gastritis 3/13 (23%); ulcer 7/10 (70%); obstruction 4/4 (100%); and miscellaneous abnormalities 6/6 (100%). The predictive accuracy of a diagnosis of ulcer was 44%. Radiology appears to be unreliable in diagnosing gastritis and recurrent ulceration in the post-operation stomach. The double-contrast technique does not offer significant improvement over the single-contrast method in evaluating these postoperative problems

  20. Multi-Institutional Evaluation of Digital Tomosynthesis, Dual-Energy Radiography, and Conventional Chest Radiography for the Detection and Management of Pulmonary Nodules.

    Science.gov (United States)

    Dobbins, James T; McAdams, H Page; Sabol, John M; Chakraborty, Dev P; Kazerooni, Ella A; Reddy, Gautham P; Vikgren, Jenny; Båth, Magnus

    2017-01-01

    Purpose To conduct a multi-institutional, multireader study to compare the performance of digital tomosynthesis, dual-energy (DE) imaging, and conventional chest radiography for pulmonary nodule detection and management. Materials and Methods In this binational, institutional review board-approved, HIPAA-compliant prospective study, 158 subjects (43 subjects with normal findings) were enrolled at four institutions. Informed consent was obtained prior to enrollment. Subjects underwent chest computed tomography (CT) and imaging with conventional chest radiography (posteroanterior and lateral), DE imaging, and tomosynthesis with a flat-panel imaging device. Three experienced thoracic radiologists identified true locations of nodules (n = 516, 3-20-mm diameters) with CT and recommended case management by using Fleischner Society guidelines. Five other radiologists marked nodules and indicated case management by using images from conventional chest radiography, conventional chest radiography plus DE imaging, tomosynthesis, and tomosynthesis plus DE imaging. Sensitivity, specificity, and overall accuracy were measured by using the free-response receiver operating characteristic method and the receiver operating characteristic method for nodule detection and case management, respectively. Results were further analyzed according to nodule diameter categories (3-4 mm, >4 mm to 6 mm, >6 mm to 8 mm, and >8 mm to 20 mm). Results Maximum lesion localization fraction was higher for tomosynthesis than for conventional chest radiography in all nodule size categories (3.55-fold for all nodules, P chest radiography for all nodules (1.49-fold, P chest radiography, as given by the area under the receiver operating characteristic curve (1.23-fold, P chest radiography or tomosynthesis. Conclusion Tomosynthesis outperformed conventional chest radiography for lung nodule detection and determination of case management; DE imaging did not show significant differences over conventional chest

  1. Compton radiography, 1

    International Nuclear Information System (INIS)

    Okuyama, Shinichi; Sera, Koichiro; Fukuda, Hiroshi; Shishido, Fumio; Matsuzawa, Taiju

    1977-01-01

    Tomographic images of an object are obtainable by irradiating it with a collimated beam of monochromatic gamma rays and recording the resultant Compton rays scattered upward at right angles. This is the scattered-ray principle of the formation of a radiation image that differs from the traditional ''silhouette principle'' of radiography, and that bears prospects of stereopsis as well as cross-section tomography. (Evans, J.)

  2. [Opportunity and challenge of post-marketing evaluation of traditional Chinese medicine].

    Science.gov (United States)

    Du, Xiao-Xi; Song, Hai-Bo; Ren, Jing-Tian; Yang, Le; Guo, Xiao-Xin; Pang, Yu

    2014-09-01

    Post-marketing evaluation is a process which evaluate the risks and benefits of drug clinical application comprehensively and systematically, scientific and systematic results of post-marketing evaluation not only can provide data support for clinical application of traditional Chinese medicine, but also can be a reliable basis for the supervision department to develop risk control measures. With the increasing demands for treatment and prevention of disease, traditional Chinese medicine has been widely used, and security issues are also exposed. How to find risk signal of traditional Chinese medicine in the early stages, carry out targeted evaluation work and control risk timely have become challenges in the development of traditional Chinese medicine industry.

  3. Industrial radiography

    International Nuclear Information System (INIS)

    Aloni, A.; Magal, O.

    1992-02-01

    This publication is meant to be a manual for industrial radiography. As such the manual concentrates on the practical aspects, presenting existing radiographic system and techniques of operation to satisfy specified quality requirements. The manual also reviews the safety aspect of performing radiographic work. (author) systems

  4. Cold neutron radiography using low power accelerator

    International Nuclear Information System (INIS)

    Kiyanagi, Yoshiaki; Iwasa, Hirokatu

    1993-01-01

    A cold neutron source which can be adopted at a low power accelerator was studied. Time-of-flight radiography using the cold neutron source was performed. It is suggested that time-of-flight cold neutron radiography has possibility to distinguish the materials more clearly than the traditional film method since large contrast differences can be obtained by using digital data of the neutron intensity at different energies from thermal to cold region. Material will be identified at the same time by this method. (author)

  5. Artifacts in digital radiography

    International Nuclear Information System (INIS)

    Min, Jung Whan; Kim, Jung Min; Jeong, Hoi Woun

    2015-01-01

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments

  6. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  7. Image quality in digital radiography

    International Nuclear Information System (INIS)

    Kuhn, H.

    1986-01-01

    The contribution deals with the potentials of digital radiography and critically evaluates the advantages of drawbacks of the image intensifier-tv-digital system; digitalisation of the X-ray film and scanning of luminescent storage foils. The evaluation is done in comparison with the image quality of the traditional, large-size X-ray picture. (orig.) [de

  8. Neutron radiography at the HFR Petten compilation of HFR Petten contributions to the second world conference on neutron radiography

    International Nuclear Information System (INIS)

    Markgraf, J.W.F.

    1986-01-01

    This booklet summarizes the six papers on neutron radiography activities at the Petten High Flux Reactor (HFR), presented at the Second World Conference on neutron radiography, held in June 1986 in Paris, France. The conference was organized by the French CEA and COFREND, and JRC Petten, HFR Division, with joint sponsorship of the national societies on Non-Destructive Testing (NDT) from the Federal Republic of Germany, United Kingdom, Japan and the United States. The Petten papers are concerned with: (i) the work of the Neutron Radiography Working Group (NRWG), an expert group operating under the auspices of the Commission of the European Communities represented by JRC Petten, HFR Division; (ii) applications of neutron radiography in research programmes performed at HFR; (iii) neutron radiography facilities at HFR; and (iv) image evaluation techniques

  9. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  10. Neutron radiography

    International Nuclear Information System (INIS)

    Hrdlicka, Z.

    1977-01-01

    Neutron radiography is a radiographic method using a neutron beam of a defined geometry. The neutron source usually consists of a research reactor, a specialized neutron radiography reactor or the 252 Cf radioisotope source. There are two types of the neutron radiography display system, viz., a system producing neutron radiography images by a photographic process or a system allowing a visual display, eg., using a television monitor. The method can be used wherever X-ray radiography is used except applications in the radiography of humans. The neutron radiography unit at UJV uses the WWR-S reactor as the neutron source and both types of the above mentioned display system. (J.P.)

  11. Neutron radiography characterization of an operating proton exchange membrane fuel cell with localized current distribution measurements

    International Nuclear Information System (INIS)

    Gagliardo, J.J.; Owejan, J.P.; Trabold, T.A.; Tighe, T.W.

    2009-01-01

    Neutron radiography has proven to be a powerful tool to study and understand the effects of liquid water in an operating fuel cell. In the present work, this experimental method is coupled with locally resolved current and ohmic resistance measurements, giving additional insight into water management and fuel cell performance under a variety of conditions. The effects of varying the inlet humidification level and the current density of the 50 cm 2 cell are studied by simultaneously monitoring electrochemical performance with a 10x10 matrix of current sensors, and liquid water volumes are measured using the National Institute of Standards and Technology (NIST) neutron imaging facility. A counter flow, straight channel proton exchange membrane (PEM) fuel cell is used to demonstrate localized performance loss corresponds to water-filled channels that impede gas transport to the catalyst layer, thereby creating an area that has low current density. Furthermore, certain operating conditions causing excess water accumulation in the channels can result in localized proton resistance increase, a result that can only be accurately observed with combined radiography and distributed electrochemical measurements.

  12. Post-operative observation of ilio-apophyseal transplants on the basis of radiography, computed tomography, autoradiography and histological assessment

    International Nuclear Information System (INIS)

    Klatt, U.

    1987-01-01

    A study in 25 rabbits, in which the acetabular roof was reinforced by inserting a wedge-shaped autologous tissue fragment of the apophysis, led to the following conclusions: That complete healing and ossification of the implant took place within the observation period; that radiography, computed tomography, autoradiography and histology consistently provided evidence in confirmation of ossification; that a wedge-shaped fragment of apophyseal cartilage is a suitable material for plastic surgery in the acetabular roof. (TRV) [de

  13. Application of direct digital radiography of nasal bone

    International Nuclear Information System (INIS)

    Gao Dengfa; Wang Haijun; Zhang Ailian; Wang Yulin

    2005-01-01

    Objective: To research the application value of direct digital radiograph (DDR ) in nasal bone imaging. Methods: One hundred cases were examined by DDR, 30 cases of them were examined by two methods both DDR and conventional radiography. All digital images were post-processed with 'MUSICA' (Multi-Scale Image Contrast Amplification), incision and largamente, analyzed and diagnosed by experienced two radiologists and two technicians. Results: One hundred cases of nasal bone, soft tissue of nose were showed excellent in DDR, and satisfactory cases were 95 and 92, respectively. Forty-six cases of nasal bone fractures were found. Thirty cases were examined by both DDR and conventional radiography, images of nasal bone, soft tissue of nose were showed, satisfactory cases were 28 in DDR; and satisfactory cases were 6 (χ 2 =20.05, P 2 =15.06, P 2 =5.14, P<0.05) in conventional and digital radiography, respectively. Conclusion: DDR images of nasal bone, soft tissue of nose was excellent, more fractures were discovered than conventional radiography. Image quality of DDR is better than conventional radiography in nasal bone imaging. (authors)

  14. Combined local current distribution measurements and high resolution neutron radiography of operating direct methanol fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Alexander; Wippermann, Klaus [Forschungszentrum Juelich GmbH (Germany). Inst. of Energy Research, IEF-3: Fuel Cells; Sanders, Tilman [RWTH Aachen (DE). Inst. for Power Electronics and Electrical Drives (ISEA); Arlt, Tobias [Helmholtz Centre Berlin (Germany). Inst. for Applied Materials

    2010-07-01

    Neutron radiography allows the investigation of the local fluid distribution in direct methanol fuel cells (DMFCs) under operating conditions. Spatial resolutions in the order of some tens of micrometers at the full test cell area are achieved. This offers the possibility to study practice-oriented, large stack cells with an active area of several hundred cm{sup 2} as well as specially designed, small test cells with an area of some cm{sup 2}. Combined studies of high resolution neutron radiography and segmented cell measurements are especially valuable, because they enable a correlation of local fluid distribution and local performance [1, 2]. The knowledge of this interdependency is essential to optimise the water management and performance respecting a homogeneous fluid, current and temperature distribution and to achieve high performance and durability of DMFCs. (orig.)

  15. Comparative study between computed radiography and conventional radiography

    International Nuclear Information System (INIS)

    Noorhazleena Azaman; Khairul Anuar Mohd Salleh; Sapizah Rahim; Shaharudin Sayuti; Arshad Yassin; Abdul Razak Hamzah

    2010-01-01

    In Industrial Radiography, there are many criteria that need to be considered based on established standards to accept or reject the radiographic film. For conventional radiography, we need to consider the optical density by using the densitometer when viewing the film on the viewer. But in the computed radiography (CR) we need to evaluate and performed the analysis from the quality of the digital image through grey value. There are many factors that affected the digital image quality. One of the factors which are affected to the digital image quality in the image processing is grey value that related to the contrast resolution. In this work, we performed grey value study measurement on digital radiography systems and compared it with exposed films in conventional radiography. The test sample is a steel step wedge. We found out the contrast resolution is higher in Computed Radiography compared with Conventional Radiography. (author)

  16. Charter of good practices in industrial radiography

    International Nuclear Information System (INIS)

    2010-01-01

    This document describes good practices in the field of industrial radiography. After having presented the main prevention and radiation protection principles, the actors inside and outside of the company, and actors intervening during an operation subcontracting in industrial radiography, this report analyzes the activity: prerequisites for work preparation, prevention coordination, work preparation, transportation, work achievement, return on experience. It addresses personnel training and information, and the dosimetric and medical monitoring of technicians in industrial radiography. Some aspects are addressed in appendix: principles (justification, optimization, and limitation), regulations, intervention form, exposure form, and so on

  17. Radiation protection and safety in industrial radiography

    International Nuclear Information System (INIS)

    1999-01-01

    The use of ionizing radiation, particularly in medicine and industry, is growing throughout the world, with further expansion likely as technical developments result from research. One of the longest established applications of ionizing radiation is industrial radiography, which uses both X radiation and gamma radiation to investigate the integrity of equipment and structures. Industrial radiography is widespread in almost all Member States. It is indispensable to the quality assurance required in modern engineering practice and features in the work of multinational companies and small businesses alike. Industrial radiography is extremely versatile. The equipment required is relatively inexpensive and simple to operate. It may be highly portable and capable of being operated by a single worker in a wide range of different conditions, such as at remote construction sites, offshore locations and cross-country pipelines as well as in complex fabrication facilities. The associated hazards demand that safe working practices be developed in order to minimize the potential exposure of radiographers and other persons who may be in the vicinity of the work. The use of shielded enclosures (fixed facilities), with effective safety devices, significantly reduces any radiation exposures arising from the work. This Safety Report summarizes good and current state of the art practices in industrial radiography and provides technical advice on radiation protection and safety. It contains information for Regulatory Authorities, operating organizations, workers, equipment manufacturers and client organizations, with the intention of explaining their responsibilities and means to enhance radiation protection and safety in industrial radiography

  18. [Sample size calculation in clinical post-marketing evaluation of traditional Chinese medicine].

    Science.gov (United States)

    Fu, Yingkun; Xie, Yanming

    2011-10-01

    In recent years, as the Chinese government and people pay more attention on the post-marketing research of Chinese Medicine, part of traditional Chinese medicine breed has or is about to begin after the listing of post-marketing evaluation study. In the post-marketing evaluation design, sample size calculation plays a decisive role. It not only ensures the accuracy and reliability of post-marketing evaluation. but also assures that the intended trials will have a desired power for correctly detecting a clinically meaningful difference of different medicine under study if such a difference truly exists. Up to now, there is no systemic method of sample size calculation in view of the traditional Chinese medicine. In this paper, according to the basic method of sample size calculation and the characteristic of the traditional Chinese medicine clinical evaluation, the sample size calculation methods of the Chinese medicine efficacy and safety are discussed respectively. We hope the paper would be beneficial to medical researchers, and pharmaceutical scientists who are engaged in the areas of Chinese medicine research.

  19. Contemporary practice education: Exploring student perceptions of an industrial radiography placement for final year diagnostic radiography students

    International Nuclear Information System (INIS)

    Wareing, A.K.; Henderson, I.

    2015-01-01

    Introduction: There is a paucity of evidence in diagnostic radiography evaluating a career path into industrial imaging despite several higher education institutes stating this route as a career option on graduation. The link between a career in industrial radiography and diagnostic routes is unknown although there are anecdotal examples of individuals transferring between the two. Successfully obtaining a first post job following graduation in diagnostic radiography can be challenging in the current financial climate. A partnership was formed with an energy sector company that offered non-destructive testing/non-destructive evaluation (NDT/NDE) employing industrial radiographic technicians. Method: As an initial pilot, 5 (n = 5) final year diagnostic radiography students visited an industrial radiography site and underwent theoretical and practical training. Following this placement they engaged in a focus group and the student perceptions/responses were explored and recorded. Results: Common themes were identified and categorised via a thematic analysis. These were; radiation safety, physics and technology, widening access, graduate attributes/transferable skill sets and working conditions. Conclusion: Student discussion focussed around the benefits of working conditions in healthcare, the value of technology, safety and physics education in alternative placements and the transferability of skills into other/industrial sectors (e.g. NDT/NDE). Contemporary practice placements are a useful pedagogical approach to develop complex conceptual theoretical constructs, such as radiation physics. An in depth evaluation between the two industries skill sets is postulated. Additionally, this could offer alternative/emerging roles to interested diagnostic radiographers potentially meeting the skill shortage in industrial radiography. - Highlights: • Research in this area is novel. No evidence could be found to evaluate the links. • Students had theoretical

  20. Practical radiation protection for radiography

    International Nuclear Information System (INIS)

    Hubbard, S.K.; Proudfoot, E.A.

    1978-01-01

    Nondestructive Testing Applications and Radiological Engineering at the Hanford Engineering Development Laboratory have developed radiation protection procedures, radiation work procedures, and safe practice procedures to assure safe operation for all radiographic work. The following topics are discussed: training in radiation safety; radiation exposure due to operations at Hanford; safeguards employed in laboratory radiography; field radiographic operations; and problems

  1. Pre-operative assessment and post-operative care in elective shoulder surgery.

    Science.gov (United States)

    Akhtar, Ahsan; Macfarlane, Robert J; Waseem, Mohammad

    2013-01-01

    Pre-operative assessment is required prior to the majority of elective surgical procedures, primarily to ensure that the patient is fit to undergo surgery, whilst identifying issues that may need to be dealt with by the surgical or anaesthetic teams. The post-operative management of elective surgical patients begins during the peri-operative period and involves several health professionals. Appropriate monitoring and repeated clinical assessments are required in order for the signs of surgical complications to be recognised swiftly and adequately. This article examines the literature regarding pre-operative assessment in elective orthopaedic surgery and shoulder surgery, whilst also reviewing the essentials of peri- and post-operative care. The need to recognise common post-operative complications early and promptly is also evaluated, along with discussing thromboprophylaxis and post-operative analgesia following shoulder surgery.

  2. Radiography - A new field among health sciences in Finland

    International Nuclear Information System (INIS)

    Pakarinen, Ritva; Jussila, Aino-Liisa

    2007-01-01

    In order to secure high quality X-ray services and efficient operation of clinical radiography, a study programme in radiography science was implemented at the University of Oulu in 1999. The need for a specific field of science has emerged as a result of social changes, such as the aging population, and the fast development of technology that has caused significant changes in the radiological working environment and clinical radiography. A need for a new, research-based informational foundation of clinical radiography is the basis for the programme. As service producers, radiographers need vast knowledge as well as specific expertise. The research object of radiography science is clinical radiography. If it was studied from the viewpoint of other sciences, the key professional skills of a radiographer would remain unexplored. Implementing an own field of science has enabled the development of radiography from its own bases. Basic research in the field is represented, for example, by the concept analysis of radiography in health sciences. Radiography science should produce research results for both clinical radiography and the instruction of radiography. So far, research results have dealt with the professional decision-making of a radiographer, the influences of computer technology on a radiographer's work and measuring the radiation exposure of a population

  3. [Exploration of how to formulate guidelines on post-marketing traditional Chinese medicine surveillance].

    Science.gov (United States)

    Zhang, Wen; Xie, Yan-Ming; Yu, Wen-Ya

    2013-09-01

    Combining the world health organization's (WHO), the United States and the European union's relevant laws and guidelines on post-marketing drug surveillance to judge the status of post-marketing surveillance of traditional Chinese medicine(TCM) in China. We found that due to the late start of post-marketing surveillance of traditional Chinese medicine, the appropriate guidelines are yet to be developed. Hence, hospitals, enterprises and research institutions do not have a shared foundation from which to compare their research results. Therefore there is an urgent need to formulate such post-marketing surveillance guidelines. This paper has used as guidance various technical documents such as, "procedures to formulate national standards" and "testing methods of management in formulating traditional Chinese medicine standards" and has combined these to produce a version of post-marketing surveillance particular to Chinese medicine in China. How to formulate these guidelines is discussed and procedures and methods to formulate technical specifications are introduced. These provide a reference for future technical specifications and will assist in the development of TCM.

  4. [Establishment of model of traditional Chinese medicine injections post-marketing safety monitoring].

    Science.gov (United States)

    Guo, Xin-E; Zhao, Yu-Bin; Xie, Yan-Ming; Zhao, Li-Cai; Li, Yan-Feng; Hao, Zhe

    2013-09-01

    To establish a nurse based post-marketing safety surveillance model for traditional Chinese medicine injections (TCMIs). A TCMIs safety monitoring team and a research hospital team engaged in the research, monitoring processes, and quality control processes were established, in order to achieve comprehensive, timely, accurate and real-time access to research data, to eliminate errors in data collection. A triage system involving a study nurse, as the first point of contact, clinicians and clinical pharmacists was set up in a TCM hospital. Following the specified workflow involving labeling of TCM injections and using improved monitoring forms it was found that there were no missing reports at the ratio of error was zero. A research nurse as the first and main point of contact in post-marketing safety monitoring of TCM as part of a triage model, ensures that research data collected has the characteristics of authenticity, accuracy, timeliness, integrity, and eliminate errors during the process of data collection. Hospital based monitoring is a robust and operable process.

  5. Detection of furcation involvement using periapical radiography and 2 cone-beam computed tomography imaging protocols with and without a metallic post: An animal study

    Energy Technology Data Exchange (ETDEWEB)

    Salineiro, Fernanda Cristina Sales; Gialain, Ivan Onone; Kobayashi-Velasco, Solange; Pannuti, Claudio Mendes; Cavalcanti, Marcelo Gusmao Paraiso [Dept. of Stomatology, School of Dentistry, University of Sao Paulo, Sao Paulo (Brazil)

    2017-03-15

    The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.

  6. Methodology for digital radiography simulation using the Monte Carlo code MCNPX for industrial applications

    International Nuclear Information System (INIS)

    Souza, E.M.; Correa, S.C.A.; Silva, A.X.; Lopes, R.T.; Oliveira, D.F.

    2008-01-01

    This work presents a methodology for digital radiography simulation for industrial applications using the MCNPX radiography tally. In order to perform the simulation, the energy-dependent response of a BaFBr imaging plate detector was modeled and introduced in the MCNPX radiography tally input. In addition, a post-processing program was used to convert the MCNPX radiography tally output into 16-bit digital images. Simulated and experimental images of a steel pipe containing corrosion alveoli and stress corrosion cracking were compared, and the results showed good agreement between both images

  7. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  8. Establishing rigour in qualitative radiography research

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, F.J. [School of Healthcare Professions, University of Salford, Salford M6 6PU (United Kingdom)], E-mail: f.j.murphy@salford.ac.uk; Yielder, J. [Medical Imaging, School of Health Sciences, Unitec, Auckland (New Zealand)

    2010-02-15

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  9. Establishing rigour in qualitative radiography research

    International Nuclear Information System (INIS)

    Murphy, F.J.; Yielder, J.

    2010-01-01

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  10. Minimally traumatic stapes surgery for otosclerosis: Risk reduction of post-operative vertigo

    Directory of Open Access Journals (Sweden)

    An-Suey Shiao

    2018-06-01

    Full Text Available Background: The author (Dr. Shiao modified traditional stapes surgery (TSS specifically for patients with otosclerosis. The proposed technique, referred to as minimally traumatic stapes surgery (MTSS, reduces the risk of subjective discomfort (i.e. vertigo and tinnitus following surgery. This paper compares the effectiveness of MTSS with that of TSS. Methods: The medical records of patients with otosclerosis after stapes surgery (TSS or MTSS were analyzed. Outcome variables included post-operative vertigo, tinnitus, and hearing success. Multivariate logistic regression analysis was used to determine the correlation between surgical technique and outcome variables. Results: TSS was performed in 23 otosclerosis ears and MTSS was performed in 33 otosclerosis ears. The risk of post-operative vertigo was significantly lower among patients that underwent MTSS (27% than among those that underwent TSS (83%, p < 0.001. No differences in the incidence of tinnitus were observed between the two groups. Post-operative audiometric outcomes were also equivalent between the two groups. However, multivariate logistic regression analysis revealed a correlation between post-operative vertigo and surgical technique (p < 0.001. Conclusion: MTSS involves a lower risk of vertigo than does TSS. MTSS helps to prevent damage to the footplate, thereby reducing the risk of footplate floating. Therefore, MTSS provides a means to overcome some of the limitations associated with the narrow surgical field in Asian patients. Keywords: Footplate floating, Minimally traumatic, Otosclerosis, Stapes surgery, Vertigo

  11. Digital luminescent radiography for diagnosis of skeletal injuries

    International Nuclear Information System (INIS)

    Buddenbrock, B.; Mueller, R.D.; John, V.; Kock, H.J.; Hirche, H.; Voss, M.; Loehr, E.; Schmit-Neuerburg, K.P.

    1992-01-01

    In the course of a comparative study 231 patients with traumatic lesions in skeletal and soft tissue areas were X-rayed using conventional film radiography and digital luminescence radiography (DLR). The results were evaluated by radiologists and traumatologists on the basis of optimised image post-processing in addition to the standard digital presentations. The imaging quality of compacta, spongiosa, soft tissues, fracture lines and osteosynthesis material was assessed in comparison with the screen-film images. Whereas the standard digital presentation in the ''conventionally adjusted'' imaging mode was inferior to the screen-film radiograph, the ''edge-enhanced'' standard presentation proved to be advantageous in the imaging of soft tissues (frequency of first-place ratings: DLR conventional 6%, screen-film system 21%, DLR edge-enhanced 31%). In the overall evaluation high-frequency filtered inverse image post-processing showed the highest diagnostic potential (frequency of first-place ratings: 41%). A conclusive assessment of metal implants is hindered by overshoot artefacts and can only be achieved through time-consuming post-processing of the stored image data. (orig.)

  12. Radiography

    Science.gov (United States)

    Gardner, C. G.

    1973-01-01

    Radiography is discussed as a method for nondestructive evaluation of internal flaws of solids. Gamma ray and X-ray equipment are described along with radiographic film, radiograph interpretation, and neutron radiography.

  13. Validation and prediction of traditional Chinese physical operation on spinal disease using multiple deformation models.

    Science.gov (United States)

    Pan, Lei; Yang, Xubo; Gu, Lixu; Lu, Wenlong; Fang, Min

    2011-03-01

    Traditional Chinese medical massage is a physical manipulation that achieves satisfactory results on spinal diseases, according to its advocates. However, the method relies on an expert's experience. Accurate analysis and simulation of massage are essential for validation of traditional Chinese physical treatment. The objective of this study is to provide analysis and simulation that can reproducibly verify and predict treatment efficacy. An improved physical multi-deformation model for simulating human cervical spine is proposed. First, the human spine, which includes muscle, vertebrae and inter- vertebral disks, are segmented and reconstructed from clinical CT and MR images. Homogeneous landmark registration is employed to align the spine models before and after the massage manipulation. Central line mass spring and contact FEM deformation models are used to individually evaluate spinal anatomy variations. The response of the human spine during the massage process is simulated based on specific clinical cases. Ten sets of patient data, including muscle-force relationships, displacement of vertebrae, strain and stress distribution on inter-vertebral disks were collected, including the pre-operation, post-operation and the 3-month follow-up. The simulation results demonstrate that traditional Chinese massage could significantly affect and treat most mild spinal disease. A new method that simulates a traditional Chinese medical massage operation on the human spine may be a useful tool to scientifically validate and predict treatment efficacy.

  14. Late post-operative hypoxaemia and organ dysfunction

    DEFF Research Database (Denmark)

    Kehlet, H; Rosenberg, J

    1995-01-01

    an adverse effect of tissue hypoxia on wound healing and on resistance to bacterial wound infections. Finally, mental confusion and surgical delirium may be related to inadequate arterial oxygenation during the late post-operative period. Late post-operative constant and episodic hypoxaemia may therefore......Constant and episodic hypoxaemia are common after major operations in the late post-operative period in the surgical ward. Recent studies have shown that hypoxaemia may be related to the development of myocardial ischaemia and cardiac arrhythmias. Experimental and clinical studies have demonstrated...

  15. Progress in digital radiography

    International Nuclear Information System (INIS)

    Cappelle, A.

    2016-01-01

    Because of its practical aspect digital radiography is more and more used in the industrial sector. There are 2 kinds of digital radiography. First, the 'computed radiography' that uses a photon-stimulated screen, and after radiation exposure this screen must be read by an analyser to get a digit image. The second type is the 'direct radiography' that allows one to get a digit radiograph of the object directly. Digital radiography uses the same radioactive nuclides as radiography with silver films: cobalt, iridium or selenium. The spatial resolution of digital radiography is less good than with classical silver film radiography but digital radiography offers a better visual contrast. (A.C.)

  16. A comparison of CO2 laser versus traditional stapedectomy outcomes.

    LENUS (Irish Health Repository)

    Ryan, S

    2012-02-01

    The aim of this study was to audit the introduction of the use of the CO2 laser into our department and to compare hearing outcomes and complication rates in patients who underwent either laser or mechanical stapedectomy. We found that the use of laser is at least as safe as the traditional approach with regards the rate of post-operative complications. One patient in the laser group suffered prolonged post-operative tinnitus, whilst one patient in the traditional group suffered prolonged post-operative vertigo. There was no evidence, however, of improved Air-Bone Gap closure compared to the traditional approach (Pre- and Post-Op Air Bone Gaps of 34 +\\/- 3 and 9 +\\/- 2 for laser stapedectomy versus 35 +\\/- 4 and 13 +\\/- 2 for traditional stapedectomy (mean +\\/- SEM)). In summary, therefore, CO2 laser surgery for otosclerosis is a safe surgical procedure resulting in similar hearing outcomes to that obtained following mechanical stapes surgery.

  17. Which technologies to replace gamma radiography?

    International Nuclear Information System (INIS)

    Zani-Demange, M.L.; Chauveau, D.

    2012-01-01

    Gamma radiography with iridium source is largely used in the industrial sector for the control of welds, tubes and pressure vessels as well as for monitoring corrosion. Hazards due to the handling of ionizing radiation sources (Ir 192 ) and constraints due to a more and more demanding regulations call for alternative methods. The French 'Institut de soudure' has led a 4-year long study (Alter-X project) and has identified 3 alternative methods for the iridium gamma radiography: -) the TOFD (Time Of Flight Diffraction) which is based on the analysis of the diffraction of ultrasound waves on the edges of defects; -) phased array ultrasound which is based on a series of elementary sensors that can be handled in an individual manner by specific electronics, the sweeping is no more manual but electronic and enables the operator to localize and size defects deep under the surface; -) digit radiography that is a common radiography in which the film is replaced by a re-usable phosphorus screen that is more sensitive and can be easily digitalized and has no need for a chemical treatment to be read. Digit radiography used with Se 75 (another gamma emitter) gives comparable or even better results than with Ir 192 but with a dose rate cut by half at least. (A.C.)

  18. Radiography – How do students understand the concept of radiography?

    International Nuclear Information System (INIS)

    Lundgren, S.M.; Lundén, M.; Andersson, B.T.

    2015-01-01

    Background: Radiography as a concept has mainly been associated with the functional role of the radiographer. The concept has been studied from a theoretical point of view. However, there is a lack of a theoretical foundation and research on the actual substance of the term radiography used in education. It is therefore important to undertake an investigation in order to determine how students after three years education understand the subject of radiography. Aim: The aim of this study was to analyse how students in the Swedish radiographers' degree program understand the concept of radiography. Method: A concept analysis was made according to the hybrid model, which combines theoretical, fieldwork and analytical phases. A summative content analysis was used to identify the number and content of statements. The empirical data were collected from questionnaires answered by radiography students at four universities in Sweden. Findings: All radiography students' exemplified radiography with statements related to the practical level although some of them also identified radiography at an abstract level, as a subject within a discipline. The attribute ‘An interdisciplinary area of knowledge’ emerged, which is an attribute on the abstract level. The practical level was described by four attributes: Mastering Medical Imaging’, ‘To accomplish images for diagnosis and interventions’, ‘Creating a caring environment’ and ‘Enabling fruitful encounters’. Conclusion: The hybrid model used was a versatile model of concept development. The results of this study have increased the understanding of what characterizes the concept of radiography in a Swedish context. - Highlights: • This concept analysis of radiography was undertaken according to a hybrid model. • In radiography humanistic aspects are emphasized, a shift from the technological perspective. • The attributes demonstrate the essence and interdisciplinary nature of radiography. • This

  19. The Delphi technique in radiography education research

    International Nuclear Information System (INIS)

    John-Matthews, J.St.; Wallace, M.J.; Robinson, L.

    2017-01-01

    Objectives: To describe and review the Delphi technique as a tool for radiographers engaged in mixed-methods research whereby agreement is required on the proficiencies needed by educational programmes for pre- and post- registration radiographers. This is achieved through a description offering a brief history of the technique. Through a literature search, radiography education research using this technique is identified. A protocol for a research project using the technique is presented. Using this worked example, advantages and disadvantages of the method are explored including sampling of participants, sample size, number of rounds and methods of feedback. Key findings: There are limited examples of the use of the Delphi technique in radiography literature including considerations on how to select experts and panel size. Conclusion: The Delphi technique is a suitable method for establishing collective agreement in the design of radiography educational interventions. Additional research is needed to deepen this evidence-based knowledge. - Highlights: • The Delphi Technique is used to gain collective agreement in forecasting healthcare education priorities. • There is increase of the use of the technique in healthcare education literature. • There are some examples of the technique in radiography education research. • A worked example of this technique is provided to critically evaluate this tool.

  20. Operative Start Time Does Not Affect Post-Operative Infection Risk.

    Science.gov (United States)

    Guidry, Christopher A; Davies, Stephen W; Willis, Rhett N; Dietch, Zachary C; Shah, Puja M; Sawyer, Robert G

    2016-10-01

    Surgical care is delivered 24 h a day at most institutions. Alarmingly, some authors have found that certain operative start times are associated with greater morbidity and mortality rates. This effect has been noted in both the public and private sector. Although some of these differences may be related to process, they may also be caused by the human circadian rhythm and corresponding changes in host defenses. We hypothesized that the time of day of an operation would impact the frequency of certain post-operative outcomes significantly. Cases at a single tertiary-care center reported to the American College of Surgeons National Surgical Quality Improvement Program over a 10-year period were identified. Operative start times were divided into six-hour blocks, with 6 am to noon serving as the reference. Standard univariable techniques were applied. Multivariable logistic regression with mixed effects modeling then was used to determine the relation between operative start times and infectious outcomes, controlling for surgeon clustering. Statistical significance was set at p operative infectious complication. Seventy percent of these infections (n = 1,506) were surgical site infections. On univariable analysis considering all cases, nighttime and evening operations had higher rates of post-operative infections than those in performed during the day (9.1% from 6 am to noon; 9.7% from noon to 6 pm; 14.8% from 6 pm to midnight; and 14.4% from midnight to 6 am; p operative start time was not associated with the risk of post-operative infection, even when emergency cases were considered independently. Our data suggest that operative start times have no correlation with post-operative infectious complications. Further work is required to identify the source of the time-dependent outcome variability observed in previous studies.

  1. Digital radiography

    International Nuclear Information System (INIS)

    Zani, M.L.

    2002-01-01

    X-ray radiography is a very common technique used to check the homogeneity of a material or the inside of a mechanical part. Generally the radiation that goes through the material to check, produced an image on a sensitized film. This method requires time because the film needs to be developed, digital radiography has no longer this inconvenient. In digital radiography the film is replaced by digital data and can be processed as any computer file. This new technique is promising but its main inconvenient is that today its resolution is not so good as that of film radiography. (A.C.)

  2. Satisfaction of Search in Chest Radiography 2015.

    Science.gov (United States)

    Berbaum, Kevin S; Krupinski, Elizabeth A; Schartz, Kevin M; Caldwell, Robert T; Madsen, Mark T; Hur, Seung; Laroia, Archana T; Thompson, Brad H; Mullan, Brian F; Franken, Edmund A

    2015-11-01

    Two decades have passed since the publication of laboratory studies of satisfaction of search (SOS) in chest radiography. Those studies were performed using film. The current investigation tests for SOS effects in computed radiography of the chest. Sixty-four chest computed radiographs half demonstrating various "test" abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Results of previous studies were reanalyzed using similar modern techniques. In the present study, adding nodules did not influence detection accuracy for the other abnormalities (P = .93), but did induce a reluctance to report them (P chest radiography (P chest radiography has changed, but it is not clear why. SOS may be changing as a function of changes in radiology education and practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  3. Low cost automatic cable winder for industrial radiography projector

    International Nuclear Information System (INIS)

    Nor Arymaswati Abdullah; Abdul Nassir Ibrahim; Shaharudin Sayuti; Glam Hadzir Patai Mohamad; Masrol Nizam Salleh; Arshad Yasin; Nur Aira Abdul Rahman

    2009-04-01

    Radiography is a well-established technique that is widely used to detect internal flaws in welds, castings and to check for misconstruction in assemblies. In general it is to verify weld quality in engineering structures such as the fabrication of pressure vessels, pipelines and storage tanks. It can be used on all metals, from light metals such as aluminium to dense metals such as lead. One of the techniques is industrial radiography projector. Industrial radiography projector is used to store radioactive materials when it is not required to expose the material under test. The projector will come together with a guide tube and control unit (cable winder and drive cable). When the source is to be used to radiograph an item, the cable winder will wind-out the source from projector to the desired location through a guide tube. Upon completion of the work the source will be retracted back into its safe shielded position in this projector. In common procedure, the operator has to be close to the exposures projector while wind-out or wind-in the source from and into the projector. This made the radiography operator receive the highest exposure among the radiation operator and this agreed by IAEA. This paper describes a winder cable that can be used to guide the movement of radiography source out of and into the projector that can be controlled by a remote control system. The system comprises of a gear, reversible motor and low frequency automatic controller. This system is powered by DC chargeable battery. (author)

  4. The clinical application of computed radiography in bedside photography of newborn

    International Nuclear Information System (INIS)

    Peng Sen; Guo Tianchang

    2005-01-01

    Objective: To evaluate the computed radiography in bedside photography of newborn, especially in chest radiography. Methods: Bedside CR images were selected in 100 cases randomly. The exposure parameters were optimized using the large latitude of CR. The details of images were post-processed and adjusted using spatial tuning technique. Then CR photography was compared with conventional X-ray photography. Results: The images acquired with CR had good contrast, high definition, and little distortion, in which the condemned image rate was 1%. While in conventional X-ray photography, the unsuccessful imaging rate is 9%. Conclusion: Bedside computed radiography of new-born, especially the chest imaging, is very helpful to improve image quality and positive rate of the diagnosis. (authors)

  5. Bobath and traditional approaches in post-stroke gait rehabilitation in adults

    OpenAIRE

    Mikołajewska Emilia

    2017-01-01

    Study aim: The aim of this study was to compare the outcomes of a study of post-stroke gait reeducation using the Bobath neuro‑developmental treatment (NDT-Bobath) method and the traditional approach.

  6. Neutron radiography applications in I.T.U. TRIGA Mark-II reactor

    International Nuclear Information System (INIS)

    Tugrul, A. B.

    2002-01-01

    Neutron radiography is an important radiographic technique which is supplied different and advanced information according to the X or gamma ray radiography. However, it has a trouble for supplying the convenient neutron sources. Tangential beam tube of Istanbul Technical University (ITU) TRIGA Mark-II Training and Research Reactor has been arranged for using neutron radiography. The neutron radiography set defined as detailed for the application of the technique. Two different techniques for neutron radiography are defined as namely, transfer method and direct method. For the transfer method dysprosium and indium screens are used in the study. But, dysprosium generally was preferred in many studies in the point of view nuclear safety. Gadolinium was used for direct method. Two techniques are compared and explained the preferring of the transfer technique. Firstly, reference composition is prepared for seeing the differences between neutron and X-ray or gamma radiography. In addition of it, some radiograph samples are given neutron and X-ray radiography which shows the different image characters. Lastly, some examples are given from archaeometric studies. One of them the brass plates of Great Mosque door in Cizre. After the neutron radiography application, organic dye traces are noticed. Other study is on a sword that belong to Urartu period at the first millennium B.C. It is seen that some wooden part on it. Some different artefacts are examined with neutron radiography from the Ikiztepe excavation site, then some animal post parts are recognized on them. One of them is sword and sheath which are corroded together. After the neutron radiography application, it can be noticed that there are a cloth between the sword and its sheath. By using neutron radiography, many interesting and detailed results are observed in ITU TRIGA Mark-II Training and Research Reactor. Some of them shouldn't be recognised by using any other technique

  7. Evidence-based radiography

    International Nuclear Information System (INIS)

    Hafslund, Bjorg; Clare, Judith; Graverholt, Birgitte; Wammen Nortvedt, Monica

    2008-01-01

    Evidence-based practice (EBP) offers the integration of the best research evidence with clinical knowledge and expertise and patient values. EBP is a well known term in health care. This paper discusses the implementation of EBP into radiography and introduces the term evidence-based radiography. Evidence-based radiography is radiography informed and based on the combination of clinical expertise and the best available research-based evidence, patient preferences and resources available. In Norway, EBP in radiography is being debated and radiographers are discussing the challenges of implementing EBP in both academic and clinical practice. This discussion paper explains why EBP needs to be a basis for a radiography curriculum and a part of radiographers' practice. We argue that Norwegian radiographers must increase participation in research and developing practice within their specific radiographic domain

  8. Mobile radiography at a music festival.

    Science.gov (United States)

    Walker, A; Brenchley, J; Hughes, N

    2009-08-01

    Limb injuries are common at music festival sites and traditionally patients seen by on-site medical services require referral to hospital emergency departments for radiographic exclusion of bony injury. This takes clinical personnel off site, increases demand on local emergency departments and is inconvenient for revellers. This is an audit of the use of a portable digital radiography system at the Virgin music festival in Staffordshire over a 3-year period.

  9. Post-operative pain prevalence, predictors, management practices ...

    African Journals Online (AJOL)

    MWASHAMBWA

    developing countries however, the prevalence of post-operative pain is relatively very high and pain control strategies ... Keywords: post-operative pain, prevalence, predictors, pain management, satisfaction, Tanzania. Introduction ..... perception and patterns of cerebral activation during noxious heat stimulation in humans.

  10. A review of digital radiography technology for valve inspection

    International Nuclear Information System (INIS)

    Stoev, K.; Guerout, F.M.; Horn, D.

    2008-01-01

    There are thousands of valves in a nuclear power plant (NPP) used for control, safety and checks in various plant systems, so there is a well-identified need for fast and reliable inspection and diagnostics of valves. Digital radiography can provide considerable improvements to the inspection and testing procedures for valves in comparison to classical film radiography. These improvements can lead to significant financial advantages by providing real-time inspection results, significantly reduced inspection and decision-making time, and reduced operational cost. Digital image processing, including digital image enhancement, digital archiving, and digital communication of the images and the results, is also a considerable advantage over classical film radiography technology. Another advantage of digital radiography technology is the improved safety and the reduced environmental impact due to reduced exposure/test times, use of smaller exclusion zones, elimination of chemical processing, and absence of disposable materials. This paper reviews the existing technology and evaluates the potential of digital radiography for inspection and diagnostics of valves. Station needs and requirements are assessed, and the safety, environmental and economical constraints of digital radiography techniques estimated. The advantages and disadvantages of different digital radiography equipment are compared, and their limitations and characteristics studied. (author)

  11. Safety culture in industrial radiography facility

    International Nuclear Information System (INIS)

    Vincent-Furo, Evelyn

    2015-02-01

    This project reviewed published IAEA materials and other documents on safety culture with specific references to industrial radiography. Safety culture requires all duties important to safety to be carried out correctly, with alertness, due thought and full knowledge, sound judgment and a proper sense of accountability. The development and maintenance of safety culture in an operating organization has to cover management systems, policies, responsibilities, procedures and organizational arrangements. The essence is to control radiation hazard, optimize radiation protection to prevent or reduce exposures and mitigate the consequences of accidents and incidents. To achieve a high degree of safety culture appropriate national and international infrastructure should exist to ensure effective training of workers and management system that supports commitment to safety culture at all level of the organization; management, managers and workforce. The result of the review revealed that all accidents in industrial radiography facilities were due to poor safety culture practices including inadequate regulatory control oversight. Some recommendations are provided and if implemented could improve safety culture leading to good safety performance which will significantly reduce accidents and their consequences in industrial radiography. These examples call for a review of safety culture in Industrial radiography. (au)

  12. Bobath and traditional approaches in post-stroke gait rehabilitation in adults

    Directory of Open Access Journals (Sweden)

    Mikołajewska Emilia

    2017-02-01

    Full Text Available Study aim: The aim of this study was to compare the outcomes of a study of post-stroke gait reeducation using the Bobath neuro‑developmental treatment (NDT-Bobath method and the traditional approach.

  13. Intra-operative colloid administration increases the clearance of a post-operative fluid load

    DEFF Research Database (Denmark)

    Borup, Tine; Hahn, Robert; Holte, K

    2009-01-01

    using volume kinetics based on the plasma dilution alone. The pre-operative plasma clearance was compared with the post-operative plasma clearance and patients served as their own control. RESULTS: The urinary excretion averaged 350 ml for the pre-operative infusion and 612 ml post-operatively, which...

  14. Receiver operating characteristic analysis of chest radiographs with computed radiography and conventional analog films

    International Nuclear Information System (INIS)

    Morioka, C.; Brown, K.; Dalter, S.; Milos, M.J.; Huang, H.K.; Kangarloo, H.; Boechat, I.M.; Batra, P.

    1988-01-01

    Receiver operating characteristic is used to compare the image quality of films obtained digitally using computed radiography (CR) and conventionally using analog film following fluoroscopic examination. Twenty-four cases, some with a solitary noncalcified nodule and/or pneumothorax, were collected. Ten radiologists have been tested viewing analog and CR digital films separately. Preliminary results indicate that there is no significant difference in the ability to detect either a pneumothorax or a solitary noncalcified nodule when comparing CR digital film with conventional analog film. A comparison of the CR digital image displayed on a 2,048-line monitor against analog and CR digital film is in progress

  15. Radiation exposure to the patient during X-ray fluoroscopy and radiography

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.

    2006-01-01

    Full text: The aim of this study is to assess the patient doses received during conventional and digital X-ray radiography, conventional fluoroscopy of the lungs, and one of the highest dose X-ray procedures - contrast examination of the large intestine (Barium enema examination). The measured quantity is Kerma area product (KAP), registered with a clinical dosimeter DRK-1 (Doza, Russia). A total number of 89 patients are included in the study. The Organ doses and Effective doses were assessed using Monte Carlo calculation code (PCXMC 1.4 (Finland). The measurements took place at the following X-ray units: a CGR (Koch and Sterzel) with two working posts - for radiography and fluoroscopy, a Philips Telediagnost (for barium enema) and an Oldelft N800HF Digidelca (for digital radiography of the chest). The typical KAP per procedure at digital radiography, conventional X-ray radiography and fluoroscopy and Barium enema examination are: 17; 95; 928 and 3630 cGy.cm 2 respectively; the average effective doses are: 0.022; 0.053; 0.728 and 8.0 mSv respectively. Doses to the lungs at digital radiography, conventional radiography and fluoroscopy are: 0.066; 0.136 and 2.412 mSv respectively and the dose to the upper and lower large intestine are: 11.7 and 8.6 mSv respectively. Conclusion: The approach used is applicable for assessment of radiation exposure to the patient during X-ray radiography and fluoroscopy. It needs registration of KAP meter readings when this device is installed on the stationary X-ray units

  16. Supervision of radiography licensees - using electronic questionnaires

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Aa. [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2005-09-15

    The results from this questionnaire gave a general view of the state of the radiography practices in Sweden, and the questionnaire hopefully contributed to improve the knowledge of these regulations for the licensees. The largest deficiencies were found in the documentation of the radiation protection organisation as well as documentation of quality assurance and operational statistics. The results of the questionnaire constitute a useful basis for selecting companies for future inspections by SSI. Those who has not answered the questionnaire and are working with site radiography can expect a visit in the near future.

  17. Radioprotection to the Gonads in Pediatric Pelvic Radiography: Effectiveness of Developed Bismuth Shield

    OpenAIRE

    Vahid Karami; Mansour Zabihzadeh; Nasim Shams; Mehrdad Golami

    2017-01-01

    Background: The use and effectiveness of traditional lead gonad shields in pediatric pelvic radiography has been challenged by several literatures over the past two decades. The aim of this study was to develop a new radioprotective gonad shields to be use in pediatric pelvic radiography. Materials and Methods: The commercially available 0.06 mm lead equivalent bismuth garment has cropped squarely and used as ovarian shield to cover the entire region of pelvis. In order to prevent deteriorati...

  18. Association between elevated pre-operative glycosylated hemoglobin and post-operative infections after non-emergent surgery

    Directory of Open Access Journals (Sweden)

    Joseph M. Blankush

    2016-09-01

    Conclusions: The risk factors of post-operative infection are multiple and likely synergistic. While pre-operative HbA1c level is not independently associated with risk of post-operative infection, there are scenarios and patient subgroups where pre-operative HbA1c is useful in predicting an increased risk of infectious complications in the post-operative period.

  19. [Post-operative infections after cosmetic tourism].

    Science.gov (United States)

    Holst-Albrechtsen, Sine; Sørensen, Lene Birk; Juel, Jacob

    2018-06-11

    Cosmetic tourism is defined as patient mobility across borders, typically constituted by patients seeking cosmetic surgery at lower costs abroad. The most common procedures are abdominoplasty, fat grafting and breast augmentation. Very little is known about the complication rates after cosmetic tourism, and there is a paucity of evidence in all aspects of cosmetic tourism. In this review, we focus on post-operative complications i.e. post-operative infections, in particular with rare microorganisms such as mycobacteria.

  20. Californium Multiplier. Part I. Design for neutron radiography

    International Nuclear Information System (INIS)

    Crosbie, K.L.; Preskitt, C.A.; John, J.; Hastings, J.D.

    1982-01-01

    The Californium Multiplier (CFX) is a subcritical assembly of enriched uranium surrounding a californium-252 neutron source. The function of the CFX is to multiply the neutrons emitted by the source to a number sufficient for neutron radiography. The CFX is designed to provide a collimated beam of thermal neutrons from which the gamma radiation is filtered, and the scattered neutrons are reduced to make it suitable for high resolution radiography. The entire system has inherent safety features, which provide for system and personnel safety, and it operates at moderate cost. In Part I, the CFX and the theory of its operation are described in detail. Part II covers the performance of the Mound Facility CFX

  1. MRI characteristics of torn and untorn post-operative menisci

    Energy Technology Data Exchange (ETDEWEB)

    Kijowski, Richard; Rosas, Humberto; Liu, Fang [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Williams, Adam [Radiology and Imaging Consultants, Colorado Springs (United States)

    2017-10-15

    To compare magnetic resonance imaging (MRI) characteristics of torn and untorn post-operative menisci. The study group consisted of 140 patients with 148 partially resected menisci who were evaluated with a repeat knee MRI examination and subsequent repeat arthroscopic knee surgery. Two musculoskeletal radiologists retrospectively assessed the following MRI characteristics of the post-operative meniscus: contour (smooth or irregular), T2 line through the meniscus (no line, intermediate signal line, intermediate-to-high signal line, and high fluid-like signal line), displaced meniscus fragment, and change in signal pattern through the meniscus compared with baseline MRI. Positive predictive values (PPV) and negative predictive values (NPV) were calculated using arthroscopy as the reference standard. All 36 post-operative menisci with no T2 line were untorn at surgery (100% NPV), whereas 46 of the 79 post-operative menisci with intermediate T2 line, 16 of the 18 post-operative menisci with intermediate-to-high T2 line, and 14 of the 15 post-operative menisci with high T2 line were torn at surgery (58.2%, 88.9%, and 93.3% PPV respectively). Additional MRI characteristics associated with torn post-operative meniscus at surgery were irregular meniscus contour (PPV 85.7%), displaced meniscus fragment (PPV 100%), and change in signal pattern through the meniscus (PPV 99.4%). Post-operative menisci with no T2 signal line were untorn at surgery. The most useful MRI characteristics for predicting torn post-operative menisci at surgery were change in signal pattern through the meniscus compared with baseline MRI, and displaced meniscus fragment followed by high T2 line through the meniscus, intermediate-to-high T2 line through the meniscus, and irregular meniscus contour. (orig.)

  2. MRI characteristics of torn and untorn post-operative menisci

    International Nuclear Information System (INIS)

    Kijowski, Richard; Rosas, Humberto; Liu, Fang; Williams, Adam

    2017-01-01

    To compare magnetic resonance imaging (MRI) characteristics of torn and untorn post-operative menisci. The study group consisted of 140 patients with 148 partially resected menisci who were evaluated with a repeat knee MRI examination and subsequent repeat arthroscopic knee surgery. Two musculoskeletal radiologists retrospectively assessed the following MRI characteristics of the post-operative meniscus: contour (smooth or irregular), T2 line through the meniscus (no line, intermediate signal line, intermediate-to-high signal line, and high fluid-like signal line), displaced meniscus fragment, and change in signal pattern through the meniscus compared with baseline MRI. Positive predictive values (PPV) and negative predictive values (NPV) were calculated using arthroscopy as the reference standard. All 36 post-operative menisci with no T2 line were untorn at surgery (100% NPV), whereas 46 of the 79 post-operative menisci with intermediate T2 line, 16 of the 18 post-operative menisci with intermediate-to-high T2 line, and 14 of the 15 post-operative menisci with high T2 line were torn at surgery (58.2%, 88.9%, and 93.3% PPV respectively). Additional MRI characteristics associated with torn post-operative meniscus at surgery were irregular meniscus contour (PPV 85.7%), displaced meniscus fragment (PPV 100%), and change in signal pattern through the meniscus (PPV 99.4%). Post-operative menisci with no T2 signal line were untorn at surgery. The most useful MRI characteristics for predicting torn post-operative menisci at surgery were change in signal pattern through the meniscus compared with baseline MRI, and displaced meniscus fragment followed by high T2 line through the meniscus, intermediate-to-high T2 line through the meniscus, and irregular meniscus contour. (orig.)

  3. Charged Particle Radiography

    International Nuclear Information System (INIS)

    Morris, Chris

    2004-01-01

    The Coulomb multiple scattering of charged particles as they pass through material allows them to be used as a radiographic probe. This forms the basis for a new kind of radiography that is finding application where conventional x-ray radiography is limited by flux or backgrounds. Charged-particle radiography is providing a versatile new probe that has advantages over conventional x-ray radiography for some unique application. Proton radiography has been used to make quantitative motion pictures of high explosive driven experiments and proves to be of great value for radiographing experiments that mock up nuclear weapon primaries for stockpile certification. By taking advantage of magnetic lens to magnify images and by using the very bright beams that can be made with electrons, charged-particle radiography may be useful for studying the fine spatial detail and very fast motion in laser driven implosion experiments at the National Ignition Facility. Finally, radiographs can be made using cosmic-ray muons for searching vehicles and cargo containers for surreptitious cargo of high z materials such as uranium or plutonium.

  4. Non-destructive evaluation utilizing imaging plates for field radiography applications

    International Nuclear Information System (INIS)

    White, Brian S.

    2016-01-01

    The oil and gas industry has utilized film radiography for the evaluation of pipeline welds for many years. The world has evolved, and today people are easily sharing digital images as part of the information revolution. Computed radiography is ready to replace film radiography for portable outdoor use applications. Computed radiography technology adoption has been contingent upon achieving acceptable image quality and getting enough imaging plate use cycles to be profitable. Image quality is dependent upon shot conditions, imaging plate type, reader settings, and scatter control. Likewise, the number of achievable use cycles is dependent upon the imaging plate design for durability and the user's operating environment. This presentation reviews the basic principles of storage phosphor imaging plates. Usage criteria and guidelines for optimum image quality and maximized overall use cycles will be discussed for various imaging plate types. A comparison of film and computed radiography imaging plate technology will be presented.

  5. Industrial radiography

    International Nuclear Information System (INIS)

    1992-01-01

    Industrial radiography is a non-destructive testing (NDT) method which allows components to be examined for flaws without interfering with their usefulness. It is one of a number of inspection methods which are commonly used in industry to control the quality of manufactured products and to monitor their performance in service. Because of its involvement in organizing training courses in all the common NDT methods in regional projects in Asia and the Pacific and Latin America and the Caribbean and in many country programmes, the Agency is aware of the importance of standardizing as far as possible the syllabi and training course notes used by the many experts who are involved in presenting the training courses. IAEA-TECDOC-628 ''Training Guidelines in Non-destructive Testing'' presents syllabi which were developed by an Agency executed UNDP project in Latin America and the Caribbean taking into account the developmental work done by the International Committee for Non-destructive Testing. Experience gained from using the radiography syllabi from TECDOC-628 at national and regional radiography training courses in the Agency executed UNDP project in Asia and the Pacific (RAS/86/073) showed that some guidance needed to be given to radiography experts engaged in teaching at these courses on the material which should be covered. The IAEA/UNDP Asia and Pacific Project National NDT Coordinators therefore undertook to prepare Radiography Training Course Notes which could be used by experts to prepare lectures for Level 1,2 and 3 radiography personnel. The notes have been expanded to cover most topics in a more complete manner than that possible at a Level 1, 2 or 3 training course and can now be used as source material for NDT personnel interested in expanding their knowledge of radiography. Refs, figs and tabs

  6. The impacts of post-media networks on the traditional media

    Directory of Open Access Journals (Sweden)

    Dr. Francisco Campos Freire

    2008-01-01

    Full Text Available The fast and successful penetration in society of the so-called social networks in the past two or three years has alarmed the traditional media. The new phenomenon reaches a wider audience, enhances advertising, achieves customization, and breaches some of the barriers of traditional media. The new communication channel is used already by millions of Internet users as their main source of information and entertainment. This research paper analyses the structure of eleven global social networks, which feature contents in Spanish and other languages, in relation to the electronic version (e-version of the main Spanish newspapers. The aim is to prove if the so-called social networks are a new type of media, a new platform for social relationships and post-media contents, which look more like the audiovisual media than the traditional newspapers.

  7. Pre-, intra- and post-operative imaging of cochlear implants

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Naguib, N.N.N.; Burck, I. [University Hospital Frankfurt (Germany). Inst. of Diagnostic and Interventional Radiology; Tawfik, A. [Mansoura Univ. (Egypt). Dept. of Diagnostic and Interventional Radiology; Emam, A. [University Hospital Alexandria (Egypt). Dept. of Diagnostic and Interventional Radiology; Nour-Eldin, A. [University Hospital Cairo (Egypt). Dept. of Radiology; Stoever, T. [University Hospital of Frankfurt (Germany). Dept. of Otolaryngology

    2015-11-15

    The purpose of this review is to present essential imaging aspects in patients who are candidates for a possible cochlear implant as well as in postsurgical follow-up. Imaging plays a major role in providing information on preinterventional topography, variations and possible infections. Preoperative imaging using DVT, CT, MRI or CT and MRI together is essential for candidate selection, planning of surgical approach and exclusion of contraindications like the complete absence of the cochlea or cochlear nerve, or infection. Relative contraindications are variations of the cochlea and vestibulum. Intraoperative imaging can be performed by fluoroscopy, mobile radiography or DVT. Postoperative imaging is regularly performed by conventional X-ray, DVT, or CT. In summary, radiological imaging has its essential role in the pre- and post-interventional period for patients who are candidates for cochlear implants.

  8. A study of television imaging system for fast neutron radiography

    International Nuclear Information System (INIS)

    Yoshii, Koji

    1992-01-01

    The neutron radiography with fast neutron beam is a very useful imaging technique for thicker objects, especially those composed of hydrogen-rich materials which are sometimes difficult to image by thermal neutron radiography. The fast neutron radiography has not been studied so much as the thermal neutron radiography. The fast neutron radiography has been studied at the fast neutron source reactor 'Yayoi' of the University of Tokyo built in Tokai-mura. The average neutron energy of the Yayoi is about 1 MeV, and the peak neutron flux at the core center is 0.8 x 10 12 at the maximum operating power of 2 kW. In the experiment on fast neutron radiography, a CR39 nuclear track detector has been used successfully. But in the Yayoi radiography procedure, about 24 hours were required for obtaining an imaging result. To get a prompt imaging result and a real-time imaging result, it is necessary to develop a fast neutron television system, and in this paper, a new fast neutron TV system is proposed. The main difference is the converter material sensitive to fast neutrons. The study on the fast neutron TV system was carried out by using the Baby Cyclotron of Japan Steel Works, and the good images were realized. (K.I.)

  9. An Australian perspective on environmental protection at uranium mines during the operational and post-operational phases

    International Nuclear Information System (INIS)

    Needham, S.

    1996-01-01

    A high level of public interest surrounds uranium mining in Australia near Kakadu National Park, and government regulatory and audit systems are in place to deliver a high level of environmental protection. There is considered to be no significant level of radiological risk of the environment, although there is evidence of radio accumulation in some organisms which is relevant to calculation of radiological dose to Aboriginal communities pursuing a traditional lifestyle in the region. Assessment of environmental risk focuses mainly on water chemistry, where the main contaminants are uranium, sulphate, and magnesium. Assessment of ecosystem health are made mainly on the basis of whole effluent tests. Post-operational protection is aimed at achieving rehabilitation compatible with likely future land use: mainly wilderness and traditional Aboriginal foraging and occasional occupation. Passive management systems with landscapes and vegetation similar to the preexisting condition, and a high degree of chemical, radiological and physiographic stability for the long term (<10000 years) are key objectives in rehabilitation planning and execution

  10. Digital radiography: study of an alternative technique to conventional radiography

    International Nuclear Information System (INIS)

    Banchet, J.; Tisseur, D.; Thomas, A.

    2009-01-01

    Digital radiography, already in use in many industrial applications, appears as a potential alternative technique to conventional radiography in the nuclear field (and more especially to the inspection of welded joints). The advantages of digital radiography are a reduced explosion risk (due to the use of lower energy and activity sources), a lower installation time, a reduced exclusion zone, and the absence of effluents. However, to the contrary of the US case, this technique may not be used in France as it is not referenced in the regulating codes (RCCM, etc.). Areva has launched a R and D study in order to characterize the equivalencies between digital and conventional radiography. First results of this study are given

  11. Pneumothorax and the Value of Chest Radiography after Ultrasound-Guided Thoracocentesis

    International Nuclear Information System (INIS)

    Pihlajamaa, K.; Bode, M.K.; Puumalainen, T.; Lehtimaeki, A.; Marjelund, S.; Tikkakoski, T.

    2004-01-01

    Purpose: To determine the incidence, the operator's experience, and other variables that may influence the development of pneumothorax or re-expansion edema after ultrasound (US)-guided thoracocentesis. Material and Methods: The medical records of 264 procedures in 212 patients who had undergone US-guided thoracocentesis in our radiology department or intensive care unit during the period 1996-2001 were retrospectively reviewed. Results: Post-thoracocentesis pneumothorax occurred in 11 cases, the incidence being 4.2% (11/264). None of the pneumothoraces occurred in the 10 mechanically ventilated patients. All but one patient with pneumothorax were asymptomatic or had only minor symptoms. Chest tube drainage was needed in one patient with a large pneumothorax. No re-expansion edema was recorded, although 1500 ml or more pleural fluid was aspirated in 29 patients. The operator's experience had no effect on the complication rate. Needle size was the only significant variable that contributed to the pneumothorax rate. Conclusion: US-guided thoracocentesis can be done equally as safely by residents as by senior radiologists. The safety and feasibility of the method are evident among mechanically ventilated intensive care patients. Our results do not support the routine use of post-thoracocentesis chest radiography

  12. Neutron radiography, techniques and applications

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1987-10-01

    After describing the principles of the ''in pool'' and ''dry'' installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objects are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neutron radiography (ASTM and Euratom Neutron Radiography Working Group) is described. The paper reviews main fields of use of neutron radiography. Possibilities of use of neutron radiography at research reactors in various scientific, industrial and other fields are mentioned. Examples are given of application of neutron radiography in industry and the nuclear field. (author)

  13. Basic principles of industrial radiography

    International Nuclear Information System (INIS)

    Bestbier, P.

    1983-01-01

    X-ray radiography and gamma radiography are used in industrial radiography. X-rays and gamma rays have the ability to penetrate materials and be absorbed by different densities. This characteristic makes them useful tools in industrial and medical radiography. The sources used for the generation of x-rays, gamma rays and radioisotopes are discussed. Films are one of the recording methods of x-radiography. The article also deals with advantages and disadvantages of radiography. Factors governing radiation exposure includes: the type of radiation source, material to be radiographed, distance, film, and the method for development. International specifications are also responsible for strict control over the standard of workmanship in industrial radiography

  14. Neutron radiography at the Paul Scherrer Institute

    International Nuclear Information System (INIS)

    Pleinert, H.; Lehmann, E.; Hammer, J.

    1994-01-01

    Neutron radiography provides an efficient tool of measurement for many applications in fundamental research as well as in industrial non-destructive testing (NDT). A neutron radiography program has been initiated at the Paul Scherrer Institute and implemented since 1992. From the beginning of 1992 until the end of 1993, a neutron facility has been in operation at the SAPHIR research reactor. Several applications have been tested and programs on two main fields of application have been established, focusing on the study of porous materials, especially concrete and granitic rock. The investigations on concrete and other building materials are carried out in cooperation with the Swiss Federal Institute of Technology in Zurich. The experimental activities are currently carried out at the Atominstitute of the Austrian Universities in Vienna, in the framework of a cooperation program with the Atominstitute. The continuation of the activities on a new radiography facility at the spallation source SINQ is planned at the Paul Scherrer Institute. In the following an overview of the method, of the actual and potential applications of neutron radiography at the Paul Scherrer Institute is given. (author) 6 figs., 1 tab., 3 refs

  15. Direct magnification radiography of the hand for the study of erosions in reumathoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Orzincolo, C; Corcione, S; Campanati, A; Scutellari, P N; Bonari, L R

    1986-01-01

    Plain films and direct magnification radiographs of the hands were performed in 34 patients affected by rheumatoid arthritis, using mammographic x-ray tube, achieved with 0.1 mm microfocus, and 1.85 x magnification factor. Direct magnification radiography has provided essential or useful diagnostic data in 44% of cases, particularly in recognizing early skeletal erosions. Nevertheless direct magnification radiography must be used only in those cases in which traditional mammographic techniques do not supply sactisfactory results.

  16. Specific radiography technique

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Beside radiography testing using x-ray machine and gamma source, there are several technique that developed specifically to complete the testing that cannot be done with the two earlier. This technique was specific based on several factor, for the example, the advantages of neutron and electron using to show the image was unique compare to x-ray and gamma. Besides that, these special radiography techniques maybe differ in how to detect the radiation get through the object. These technique can used to inspect thin or specimen that contained radioactive material. There are several technique will discussed in this chapter such as neutron radiography, electron radiography, fluoroscopy and also autoradiography.

  17. New prospect in neutron radiography

    International Nuclear Information System (INIS)

    Cluzeau, S.

    1991-01-01

    Neutron radiography is a very useful non-destructive testing (NDT) method which frequently complements classical X-ray inspection. Numerous inspections in some fields are currently performed at reactor-based neutron radiography facilities but many other interesting applications in different fields are at present not considered because the objects to be tested cannot be moved to a reactor. It is the goal of the DIANE project, to allow the utilization of this NDT method in industrial facilities by developing a safe and convenient neutron radiography equipment using an ''on-off'' neutron source. As a result of the efforts of the four European partners, a first laboratory demonstration model is currently in operation in Germany and a fully mobile second one is expected by the end of 1992. Good radiographs are obtained with exposure times in the range of a few seconds to ten minutes using an electronic imaging system. The fast neutron generator uses a sealed neutron tube delivering 5.10 11 neutrons.cm -2 .s -1 in 4 π steradian; with a collimator ratio of about 12, the fluence rate onto the object is then close to 1,5.10 5 thermal neutrons.cm -2 .s -1 . (author)

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small dose ... limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is ...

  20. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  1. Ultrasonography and radiography to identify early post traumatic myosistis ossificans in an 18-year-old male: a case report.

    Science.gov (United States)

    Yochum, Alicia M; Reckelhoff, Kenneth; Kaeser, Martha; Kettner, Norman W

    2014-06-01

    The purpose of this case report is to describe a patient with post traumatic myositis ossificans (PTMO) of the anterior thigh following blunt trauma and discuss the incidence, clinical presentation, management, and imaging findings. An 18-year-old male presented to a chiropractic clinic with a chief complaint of left knee pain and reduced range of motion after an impact injury to his left anterior thigh during hurdling 6 weeks earlier. Immediately after the injury, he presented to the emergency department where radiography of the left knee was negative and he was diagnosed with a muscle sprain. Follow-up radiography and ultrasonography of the left knee in a chiropractic radiology department revealed ossification consistent with PTMO within his vastus intermedius. The patient underwent a course of rehabilitation for 2 months including ice, class IV cold laser and vibration applied to his anterior thigh, and myofascial release of his quadriceps musculature with targeted and progressive rehabilitative exercises. His left knee pain resolved within 2 weeks of care. He resumed sports participation (American football) pain-free, while wearing protective padding over the affected thigh, 1 month after presentation, which was approximately 2 1/2 months following his injury. This case demonstrates that ultrasonography may have the capability to detect early phases of PTMO approximately 2 weeks prior to radiographic evidence and to monitor progression throughout its course.

  2. Digital radiography

    International Nuclear Information System (INIS)

    Kusano, Shoichi

    1993-01-01

    Firstly, from an historic point of view, fundamental concepts on digital imaging were reviewed to provide a foundation for discussion of digital radiography. Secondly, this review summarized the results of ongoing research in computed radiography that replaces the conventional film-screen system with a photo-stimulable phosphor plate; and thirdly, image quality, radiation protection, and image processing techniques were discussed with emphasis on picture archiving and communication system environment as our final goal. Finally, future expansion of digital radiography was described based on the present utilization of computed tomography at the National Defense Medical College Hospital. (author) 60 refs

  3. Radiography - A conceptual approach

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, Sanna-Mari [Department of Nursing Science and Health Administration, University of Oulu, P.O. Box 5000, FIN-90014 (Finland)], E-mail: sanna-mari.ahonen@oulu.fi

    2008-11-15

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline.

  4. Radiography - A conceptual approach

    International Nuclear Information System (INIS)

    Ahonen, Sanna-Mari

    2008-01-01

    Aim: The purpose of this article is to describe interdisciplinary comparison of the attributes of the concept of radiography in health sciences, physics and technology on the grounds of concept analysis. Background: The concept of radiography is widely used in health sciences, physics and technology. However, the content of the concept may vary. In order to clarify the concept of radiography, the concept must be systematically examined and defined in linguistic form. Method: The concept of radiography was analysed by using the evolutionary method of concept analysis. The data were collected through discretionary sampling and consisted of literature and Internet pages. Qualitative content analysis was employed for analysing the data. Findings: As a result of concept analysis, the concept of radiography in health sciences was determined as expertise of radiographers in the use of radiation, which is dual, dynamic, social and situation-related in nature, and typically based on versatile synthesis. Regarding the attributes identified, the concept of radiography has both similarities and differences between health sciences, physics and technology. Conclusions: The concept of radiography was found to be more abstract, wider, more complex and more radiographer-centred in health sciences than in other disciplines. The content of the concept of radiography seems to vary according to the discipline

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive ...

  7. Association between elevated pre-operative glycosylated hemoglobin and post-operative infections after non-emergent surgery.

    Science.gov (United States)

    Blankush, Joseph M; Leitman, I Michael; Soleiman, Aron; Tran, Trung

    2016-09-01

    A chronic state of impaired glucose metabolism affects multiple components of the immune system, possibly leading to an increased incidence of post-operative infections. Such infections increase morbidity, length of stay, and overall cost. This study evaluates the correlation between elevated pre-operative glycosylated hemoglobin (HbA1c) and post-operative infections. Adult patients undergoing non-emergent procedures across all surgical subspecialties from January 2010 to July 2014 had a preoperative HbA1c measured as part of their routine pre-surgical assessment. 2200 patient charts (1100 operative infection (superficial surgical site infection, deep wound/surgical space abscess, pneumonia, and/or urinary tract infection as defined by Centers for Disease Control criteria) within 30 days of surgery. Patients with HbA1c infection rate (3.8% in the HbA1c infection. Elevated HbA1c was, however, predictive of significantly increased risk of post-operative infection when associated with increased age (≥81 years of age) or dirty wounds. The risk factors of post-operative infection are multiple and likely synergistic. While pre-operative HbA1c level is not independently associated with risk of post-operative infection, there are scenarios and patient subgroups where pre-operative HbA1c is useful in predicting an increased risk of infectious complications in the post-operative period.

  8. [Clinical orientation and thought on several problems in post-marketed reassessment of traditional Chinese medicine].

    Science.gov (United States)

    Wang, Xin; Su, Xia; Yu, Jie; Xie, Yanming; Wang, Yongyan

    2011-10-01

    The post-marketed reassessment is an important link to ensure the safety and effectiveness of traditional chinese medicine. It is also the expansion and stretch of new drug evaluation. Through the systematic, standard, rigorous post-marketed reassessment, the enterprise can full access to drugs after listing the efficacy and safety information, evaluate the interests and risk of the drug and provide the scientific basis for the drug use. It can also provide timely, scientific technology basis for government health decisions, the enterprise marketing decision and public health security. This paper mainly discussed the thought on clinical orientation of traditional chinese medicine in the post-marketed reassessment and how to reach the goal through systematic consideration and overall plan.

  9. Urinary tract infections and post-operative fever in percutaneous nephrolithotomy.

    Science.gov (United States)

    Gutierrez, Jorge; Smith, Arthur; Geavlete, Petrisor; Shah, Hemendra; Kural, Ali Riza; de Sio, Marco; Amón Sesmero, José H; Hoznek, András; de la Rosette, Jean

    2013-10-01

    To review the incidence of UTIs, post-operative fever, and risk factors for post-operative fever in PCNL patients. Between 2007 and 2009, consecutive PCNL patients were enrolled from 96 centers participating in the PCNL Global Study. Only data from patients with pre-operative urine samples and who received antibiotic prophylaxis were included. Pre-operative bladder urine culture and post-operative fever (>38.5°C) were assessed. Relationship between various patient and operative factors and occurrence of post-operative fever was assessed using logistic regression analyses. Eight hundred and sixty-five (16.2%) patients had a positive urine culture; Escherichia coli was the most common micro-organism found in urine of the 350 patients (6.5%). Of the patients with negative pre-operative urine cultures, 8.8% developed a fever post-PCNL, in contrast to 18.2% of patients with positive urine cultures. Fever developed more often among the patients whose urine cultures consisted of Gram-negative micro-organisms (19.4-23.8%) versus those with Gram-positive micro-organisms (9.7-14.5%). Multivariate analysis indicated that a positive urine culture (odds ratio [OR] = 2.12, CI [1.69-2.65]), staghorn calculus (OR = 1.59, CI [1.28-1.96]), pre-operative nephrostomy (OR = 1.61, CI [1.19-2.17]), lower patient age (OR for each year of 0.99, CI [0.99-1.00]), and diabetes (OR = 1.38, CI [1.05-1.81]) all increased the risk of post-operative fever. Limitations include the use of fever as a predictor of systemic infection. Approximately 10% of PCNL-treated patients developed fever in the post-operative period despite receiving antibiotic prophylaxis. Risk of post-operative fever increased in the presence of a positive urine bacterial culture, diabetes, staghorn calculi, and a pre-operative nephrostomy.

  10. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  11. Chest X ray effective doses estimation in computed radiography

    International Nuclear Information System (INIS)

    Abdalla, Esra Abdalrhman Dfaalla

    2013-06-01

    Conventional chest radiography is technically difficult because of wide in tissue attenuations in the chest and limitations of screen-film systems. Computed radiography (CR) offers a different approach utilizing a photostimulable phosphor. photostimulable phosphors overcome some image quality limitations of chest imaging. The objective of this study was to estimate the effective dose in computed radiography at three hospitals in Khartoum. This study has been conducted in radiography departments in three centres Advanced Diagnostic Center, Nilain Diagnostic Center, Modern Diagnostic Center. The entrance surface dose (ESD) measurement was conducted for quality control of x-ray machines and survey of operators experimental techniques. The ESDs were measured by UNFORS dosimeter and mathematical equations to estimate patient doses during chest X rays. A total of 120 patients were examined in three centres, among them 62 were males and 58 were females. The overall mean and range of patient dosed was 0.073±0.037 (0.014-0.16) mGy per procedure while the effective dose was 3.4±01.7 (0.6-7.0) mSv per procedure. This study compared radiation doses to patients radiographic examinations of chest using computed radiology. The radiation dose was measured in three centres in Khartoum- Sudan. The results of the measured effective dose showed that the dose in chest radiography was lower in computed radiography compared to previous studies.(Author)

  12. Digital radiography in NDT applications

    International Nuclear Information System (INIS)

    Deprins, E.

    2004-01-01

    A lot of film radiography could be replaced by today's technologies in the field of digital radiography. Only few of these applications have indeed replaced film. The choice to go digital depends on cost, quality requirement, workflow and throughput. Digital images offer a lot of advantages in terms of image manipulation and workflow. But despite the many advantages, a lot of considerations are needed before someone can decide to convert his organization from conventional to digital radiography. This paper gives an overview of all different modalities that can be used in digital radiography with today's technologies, together with the experiences of the pioneers of digital radiography. Film Scanning, Computed Radiography and Digital Radiography by using of different kinds of flat panel detectors all have their specific application fields and customers. What is the status of the technology today, which advantages brings digital radiography, and which are the limitations radiographers have to consider when replacing film by digital systems. (author)

  13. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  14. Qualitative discussion of quantitative radiography

    International Nuclear Information System (INIS)

    Berger, H.; Motz, J.W.

    1975-01-01

    Since radiography yields an image that can be easily related to the tested object, it is superior to many nondestructive testing techniques in revealing the size, shape, and location of certain types of discontinuities. The discussion is limited to a description of the radiographic process, examination of some of the quantitative aspects of radiography, and an outline of some of the new ideas emerging in radiography. The advantages of monoenergetic x-ray radiography and neutron radiography are noted

  15. Neutron radiography (NRAD) reactor 64-element core upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately ±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  16. Safety relevant failure mechanisms in the post-operational phase

    International Nuclear Information System (INIS)

    Mayer, Gerhard; Stiller, Jan Christopher; Roemer, Sarah

    2017-03-01

    When the 13"t"h amendment of the Atomic Energy Act came into force, eight Germ an nuclear power plant units had their power operating licences revoked and are now in the so-called post operation phase. Of the remaining nuclear power plants, one have by now also entered the post operation phase, with those left in operation bound for entering this phase sometime between now and the end of 2022. Therefore, failure mechanisms that are particularly relevant for post operation were to be identified and described in the frame of the present project. To do so, three major steps were taken: Firstly, recent national and international pertinent literature was evaluated to obtain indications of failure mechanisms in the post operation phase. It turned out that most of the national and international literature deals with the general procedure of the transition from power operation to decommissioning and dismantling. However, there were also some documents providing detailed indications of possible failure mechanisms in post operation. This includes e.g. the release of radioactive materials caused by the drop of containers, chemical impacts on systems important to safety in connection with decontamination work, and corrosion in connection with the storage of the core in the spent fuel pool, with the latter leading to the jamming of the fuel assemblies in the storage racks and a possible reduction of coolant circulation. In a second step, three safety analyses of pressurised water reactors prepared by the respective plant operators were evaluated to identify failure mechanisms based on systems engineering. The failure mechanisms that were found here include e.g. faults in the boric acid concentration of the reactor coolant, damage to the equipment airlock upon the unloading of Castor casks, leakages in connection with primary system decontamination, and the drop of packages holding radioactive residual materials or waste with subsequent mobilisation of radioactive aerosols

  17. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition); Surete radiologique en radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-05-15

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in Horizontal-Ellipsis shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  18. Radiography inspection of weld for nuclear fuel rod

    International Nuclear Information System (INIS)

    Zhang Kai; Zhang Xichang

    1995-05-01

    The survey of radiography inspection, advantages, disadvantages and applications of main kinds of radiography inspection methods are presented. Emphasis is put upon the structure and functions of X-ray flaw detecting device for nuclear fuel rod welds, the actuating program of the device, as well as the structure of some key mechanism and the functions of them. The analysis is made upon the actuating principles. Finally, the test of long-term operation proves the device to be stable in operation, reliable in action, to possess high level of automation and high sensitivity and it can simultaneously perform on-line X-ray inspection of 25 nuclear fuel rods with a diameter less than 10 mm, and meet the requirements of large-scale production of nuclear fuel rods (5 figs.)

  19. Advantages of digital radiography: The DSI system

    International Nuclear Information System (INIS)

    Drouillard, J.

    1990-01-01

    The experience gained over a period of several months, applying the digital and image-enhanced radiography with the DSI system for examination of some hundreds of patients, has confirmed in our eyes the system's diagnostic and economic efficiency, and the important achievement of radiation dose abatement. Looking at the current results and improvements under way (Release 2), there is reason enough to support an extension of the range of indications, especially regarding arteriography and interventional radiography. According to our experience, the DSI system meets the requirements of a modern radiology department: reduction of operating costs, limitation of radiation dose, efficiency enhancement by digital imaging. (orig.) [de

  20. Compassionate care in radiography recruitment, education and training: A post-Francis Report review of the current literature and patient perspectives

    International Nuclear Information System (INIS)

    Bleiker, J.; Knapp, K.M.; Hopkins, S.; Johnston, G.

    2016-01-01

    Compassion is elemental in the care of a patient during their medical imaging (MI) procedure and is highly topical in the light of the Francis Report. The patient–practitioner interaction is an amalgam of context, communication and individual differences, and whilst compassion is a term in common parlance in the media, policy and radiographers' professional documents, its meaning and manifestation in radiography recruitment, education and practice are less clearly articulated. A review of the existing literature was undertaken, including a small scale study exploring patients' experiences in diagnostic medical imaging. Themes from the study included communication; competence; emotions; attitudes and relationships, but notably absent was any mention of compassion per se. Radiography research would benefit from further exploratory work into the nature of compassionate patient care in the unique context of the medical imaging encounter; offering an evidence-based contribution to radiography in the light of the Francis Report. - Highlights: • An increased focus on compassion was recommended in the Francis Report. • Best compassionate care is a requirement in radiographers' Code of Professional Conduct. • The meaning of compassionate patient care in radiography is not well understood. • Equally neither is the expression of compassion in radiography. • Research into compassion will contribute to evidence-based practice in radiography.

  1. Radiography at CERN

    CERN Multimedia

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  2. An overview of digital radiography

    International Nuclear Information System (INIS)

    Aweligiba, S. A.

    2013-04-01

    The medical application of radiography has gained wider study since diagnostic radiology plays a very important role in modern medicine for fast diagnosis and therapy. Digital radiography is a relatively new technology that promises greater accuracy, lesser dose and better manipulation of patient radiology images in hospitals. In this study, a general discussion on digital radiography has been presented. The presentation focuses on the optimisation of doses to patients in the medical application of digital radiography, quality control and quality assurance. A brief presentation on performance indicators in digital radiography has also been presented. The advantages of digital radiography over the conventional film/screen system have been elaborated and its limitations are also outlined. (author)

  3. [Strategy of constructing post-market integral evaluation system of traditional Chinese medicine injection].

    Science.gov (United States)

    Zhang, Xiao-Yu; Wang, Yan-Ping; Lin, Li-Kai; Shang, Hong-Cai; Wang, Yong-Yan

    2017-08-01

    As an important representative of modern Chinese medicine, traditional Chinese medicine (TCM) injzection has become an indispensable part of the Chinese medicine industry. However, its development is now restricted by the bottleneck of insufficient core competitiveness, low-level research and production, even injection quality and the safe use are not guaranteed. Thus, it is urgent to reevaluate post-marketing TCM injection generally and to make secondary development. Under current circumstances, taking major brands which have good clinical and market foundation, as well as research value, as the main subject of cultivation and evaluation is an important approach to innovative development of TCM injection industry. Unlike oral proprietary Chinese medicine, the cultivatation of major brands of TCM injection needs higher technical support, quality standards and more timely feedback. Therefore, a post-market integral evaluation system adaptive to TCM injection is required. This article discussed some key points on the construction of a post-market integral evaluation system of TCM injection in three levels: optimizing evaluation methods, building synergistic innovation platforms which combine the medical research institutions and pharmaceutical enterprises, and finally constructing the integral evaluation system. A "five to one" structure has been proposed to enhance TCM injection effectiveness, safety and adaptability on the whole, which are from the following aspects: mechanism research, clinical evidence validation, literature information mining, sustainable development of resources and industrialization operation. Copyright© by the Chinese Pharmaceutical Association.

  4. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Duchazeaubeneix, J.C.; Faivre, J.C.; Garreta, D.

    1982-10-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: direct 3- dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore, it is a well adapted method to gating techniques allowing the radiography of fast periodic moving systems. Results obtained on different objects (light and heavy materials) are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiography faster and to get a practical method are discussed

  5. Post-mortem radiography of the lungs: Experiments to compare various methods of examination and descriptions of their usefulness in actual practice

    International Nuclear Information System (INIS)

    Pankow, W.

    1986-01-01

    Described is the post-mortem examination of the isolated lung using radiologic-morphologic and histologic methods. Comparisons are made ragarding practical value of the conservation techniques chosen, which were the method of Markaria and Heitzmann that is based on fixing in alcohol and air drying and the nitrogen freezing method developed by Rau and colleagues. Both methods ensure adequate visualition of the pulmonary ultrastructure by X-rays, even though this observation should be qualified by the fact that pulmonary tissue fixed in alcohol tends to shrink and that intraalveolar edema are thus artificially reduced. Either of the methods under investigation permits angiographic and bronchographic examinations to be carried out without difficulty. In macroscopic evaluations better results are obtained for lungs fixed in alcohol. Freeze-dried samples offer advantages in the histological assessment of the pulmonary ultrastructure. Post-mortem radiography of the lungs is particularly valuable in the analysis of pathological changes in the pulmonary structure. (MBC) [de

  6. Efficacy of daily bedside chest radiography as visualized by digital luminescence radiography

    International Nuclear Information System (INIS)

    Kirchner, J.; Stueckle, C.A.; Schilling, E.M.; Peters, J.

    2001-01-01

    To determine the diagnostic impact of daily bedside chest radiography in comparison with digital luminescence technique (DLR; storage phosphor radiography) and conventional film screen radiography, a prospective randomized study was completed in 210 mechanically ventilated patients with a total of 420 analysed radiographs. The patients were allocated to two groups: 150 patients underwent DLR, and 60 patients underwent conventional film screen radiography. Radiological analysis was performed consensually and therapeutic efficacy was assessed by the clinicians. There was no statistical significant difference between the frequency of abnormal findings seen on DLR and conventional film screen radiography. In total, 448 abnormal findings were present in 249 of 300 DLR and 97 of 120 conventional film screen radiographs. The most common findings were signs of overhydration (41 %), pleural effusion (31%), partial collapse of the lung (11%) and pneumothorax (2%). One hundred and twenty-three of 448 (27%) of these abnormal findings were thought to have a considerable impact on patient management. The high rate of abnormal findings with significant impact on patient management suggests that the use of daily bedside chest radiography may be reasonable. Copyright (2001) Blackwell Science Pty Ltd

  7. Military radiography

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Historic military uses of radiography are discussed in this chapter: Battle of Adowa in 1986 was the first. Besides describing the early campaigns in which radiography was used, the author discusses the problems faced: a reliable source of electricity; the problems of extreme heat; moving and breakage of equipment. Numerous historical photographs are included. 9 refs

  8. Post-operative pain control after tonsillectomy: dexametasone vs tramadol.

    Science.gov (United States)

    Topal, Kubra; Aktan, Bulent; Sakat, Muhammed Sedat; Kilic, Korhan; Gozeler, Mustafa Sitki

    2017-06-01

    Tramadol was found to be more effective than dexamethasone in post-operative pain control, with long-lasting relief of pain. This study aimed to compare the effects of pre-operative local injections of tramadol and dexamethasone on post-operative pain, nausea and vomiting in patients who underwent tonsillectomy. Sixty patients between 3-13 years of age who were planned for tonsillectomy were included in the study. Patients were divided into three groups. Group 1 was the control group. Patients in Group 2 received 0.3 mg/kg Dexamethasone and Group 3 received 0.1 mg/kg Tramadol injection to the peritonsillary space just before the operation. Patients were evaluated for nausea, vomiting, and pain. When the control and the dexamethasone groups were compared; there were statistically significant differences in pain scores at post-operative 15 and 30 min, whereas there was no statistically significant difference in pain scores at other hours. When the control and tramadol groups were compared, there was a statistically significant difference in pain scores at all intervals. When tramadol and dexamethasone groups were compared, there was no statistically significant difference in pain scores at post-operative 15 and 30 min, 1 and 2 h, whereas there was a statistically significant difference in pain scores at post-operative 6 and 24 h.

  9. Study of a Loop Heat Pipe Using Neutron Radiography

    International Nuclear Information System (INIS)

    C. Thomas Conroy; A. A. El-Ganayni; David R. Riley; John M. Cimbala; Jack S. Brenizer, Jr.; Abel Po-Ya Chuang; Shane Hanna

    2001-01-01

    An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design

  10. E-learning in an undergraduate radiography programme: Example of an interactive website

    International Nuclear Information System (INIS)

    White, Peter; Cheung, Alice K.Y.

    2006-01-01

    Purpose: To demonstrate how e-learning can be integrated into an undergraduate radiography programme, using an academic subject dealing with ethico-legal issues as an example. Information provided could be applied to any form of online learning. Methods: One academic subject from an undergraduate radiography programme, Case-Based Learning for Professional Studies, which had previously been taught using traditional face-to-face methods, was transformed into an e-learning format. Students who experienced the new e-learning format were evaluated by means of an online evaluation questionnaire. Results: Eighty-three percentage of respondents felt confident/semi-confident about participating in online Chat sessions. Around 34% of respondents thought that the Discussion Board was useful for communicating with fellow students. Nearly 70% of respondents believed that access to online materials enabled them to prepare for lectures and tutorials. However, 34% of students preferred more face-to-face lectures/tutorials. Overall, feedback was positive. Conclusion: Course providers and other relevant stakeholders need to be proactive in determining ways to facilitate undergraduate and post-registration development and learning. E-learning can be utilized to benefit learners who wish to work at their own pace and who cannot attend courses at remote sites. Individuals can reap the benefits of an online learning format and affording learners more flexibility and providing guidance for them, by means of a website, may help to promote a positive attitude to lifelong learning

  11. E-learning in an undergraduate radiography programme: Example of an interactive website

    Energy Technology Data Exchange (ETDEWEB)

    White, Peter [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)]. E-mail: orpwhite@polyu.edu.hk; Cheung, Alice K.Y. [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)]. E-mail: alice.cheung@iee.org

    2006-08-15

    Purpose: To demonstrate how e-learning can be integrated into an undergraduate radiography programme, using an academic subject dealing with ethico-legal issues as an example. Information provided could be applied to any form of online learning. Methods: One academic subject from an undergraduate radiography programme, Case-Based Learning for Professional Studies, which had previously been taught using traditional face-to-face methods, was transformed into an e-learning format. Students who experienced the new e-learning format were evaluated by means of an online evaluation questionnaire. Results: Eighty-three percentage of respondents felt confident/semi-confident about participating in online Chat sessions. Around 34% of respondents thought that the Discussion Board was useful for communicating with fellow students. Nearly 70% of respondents believed that access to online materials enabled them to prepare for lectures and tutorials. However, 34% of students preferred more face-to-face lectures/tutorials. Overall, feedback was positive. Conclusion: Course providers and other relevant stakeholders need to be proactive in determining ways to facilitate undergraduate and post-registration development and learning. E-learning can be utilized to benefit learners who wish to work at their own pace and who cannot attend courses at remote sites. Individuals can reap the benefits of an online learning format and affording learners more flexibility and providing guidance for them, by means of a website, may help to promote a positive attitude to lifelong learning.

  12. Rethinking the making and breaking of traditional and statutory institutions in post-Nkrumah Ghana

    DEFF Research Database (Denmark)

    Stacey, Paul Austin

    2016-01-01

    This article examines a complex dispute over the jurisdictions of traditional and statutory institutions that traversed shifts in forms of government in Ghana for nearly a decade following the ousting of Kwame Nkrumah in February 1966. The analysis emphasizes underlying processes of continuity...... a rethinking of the notion that the post-Nkrumah era heralded a state-initiated revival of traditional institutions....

  13. Proton nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1982-04-01

    Nuclear scattering of protons allows to radiograph objects with specific properties: 3-dimensional radiography, different information as compared to X-ray technique, hydrogen radiography. Furthermore the nuclear scattering radiography (NSR) is a well adapted method to gating techniques allowing the radiography of fast periodic moving objects. Results obtained on phantoms, formalin fixed head and moving object are shown and discussed. The dose delivery is compatible with clinical use, but at the moment, the irradiation time is too long between 1 and 4 hours. Perspectives to make the radiograph faster and to get a practical method are discussed

  14. The stationary neutron radiography system

    International Nuclear Information System (INIS)

    Weeks, A.A.; Newell, D.L.; Heidel, C.C.

    1990-01-01

    To provide the high intensity neutron beam and support systems necessary for radiography, the Stationary Neutron Radiography System was constructed at McClellan Air Force Base. The Stationary Neutron Radiography System utilizes a one megawatt TRIGA reactor contained in an Aluminium tank surrounded by eight foot thick concrete walls. There are four neutron beam tubes at inclined angles from the reactor core to separate radiography bays. In three of the bays, robotic systems manipulate aircraft components in the neutron beam, while real-time imaging systems provide images concurrent with the irradiation. Film radiography of smaller components is performed in the remaining bay

  15. Post-operative urinary retention in a general surgical population

    DEFF Research Database (Denmark)

    Dreijer, Bjørn; Møller, Morten H; Bartholdy, Jens

    2011-01-01

    Post-operative urine retention is a frequent and serious complication. The aims of this study were to evaluate the prevalence of post-operative urinary retention in a general surgical population and to identify the perioperative risk factors for developing this condition....

  16. [Process and key points of clinical literature evaluation of post-marketing traditional Chinese medicine].

    Science.gov (United States)

    Liu, Huan; Xie, Yanming

    2011-10-01

    The clinical literature evaluation of the post-marketing traditional Chinese medicine is a comprehensive evaluation by the comprehensive gain, analysis of the drug, literature of drug efficacy, safety, economy, based on the literature evidence and is part of the evaluation of evidence-based medicine. The literature evaluation in the post-marketing Chinese medicine clinical evaluation is in the foundation and the key position. Through the literature evaluation, it can fully grasp the information, grasp listed drug variety of traditional Chinese medicines second development orientation, make clear further clinical indications, perfect the medicines, etc. This paper discusses the main steps and emphasis of the clinical literature evaluation. Emphasizing security literature evaluation should attach importance to the security of a comprehensive collection drug information. Safety assessment should notice traditional Chinese medicine validity evaluation in improving syndrome, improveing the living quality of patients with special advantage. The economics literature evaluation should pay attention to reliability, sensitivity and practicability of the conclusion.

  17. Wind Turbine Blade Nondestructive Testing with a Transportable Radiography System

    Directory of Open Access Journals (Sweden)

    J. G. Fantidis

    2011-01-01

    Full Text Available Wind turbines are becoming widely used as they are an environmentally friendly way for energy production without emissions; however, they are exposed to a corrosive environment. In addition, as wind turbines typically are the tallest structures in the surrounding area of a wind farm, it is expected that they will attract direct lightning strikes several times during their operating life. The purpose of this paper is to show that the radiography with a transportable unit is a solution to find defects in the wind turbine blade and reduce the cost of inspection. A transportable neutron radiography system, incorporating an Sb–Be source, has been simulated using the MCNPX code. The simulated system has a wide range of radiography parameters.

  18. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... Resources Professions Site Index A-Z X-ray (Radiography) - Chest Chest x-ray uses a very small dose ... Radiography? What is a Chest X-ray (Chest Radiography)? The chest x-ray is the most commonly performed diagnostic ...

  19. Post Operative Cognitive Dysfunction (POCD in Geriatric Population

    Directory of Open Access Journals (Sweden)

    Rajesh MC

    2015-10-01

    Full Text Available Post-operative mental dysfunction and confusion in aged patients is a well recognized entity. Commonly known as post-operative delirium and cognitive dysfunction (POCD, these are important for any peri-operative physician dealing with geriatric population. The incidence is more in older patients with pre-existing impairment. Impact of POCD is grave. This can result in poor rehabilitation outcome and increased hospital stay. Incidence ranges from 15-50% with ˂5% for cataract surgery and as high as 60% after hip replacement procedures.

  20. Syndesmotic Malreduction after Ankle ORIF; Is Radiography Sufficient?

    Directory of Open Access Journals (Sweden)

    Alireza Manafi Rasi

    2013-12-01

    Full Text Available   Background: Ankle fractures, especially those resulting from external rotation mechanisms are associated with injury to the distal tibiofibular syndesmosis. Some authors have recommended performing CT scanning after open ankle surgery to evaluate the reduction of syndesmosis. In this current study, we aimed to investigate the sensitivity of plain radiography in diagnosing syndesmosis malreduction after open reduction and internal fixation (ORIF in patients with ankle fractures.   Methods: Thirty patients with ankle fractures participated in this prospective study. ORIFs were performed with respect to all of the technical guidelines shown in orthopedic literature for exact syndesmosis reduction, such as fibular length and proper settings. In the operating room, plain radiography was performed in anteroposterior, mortise and lateral views to assess whether syndesmosis was malreduced. If malreduction was detected, the patient was revised. As the gold standard, patients underwent postoperative bilateral CT scanning to investigate the syndesmosis reduction which was then compared to the healthy side. Finally, the sensitivity of plain radiography in the diagnosis of syndesmosis malreduction was determined by comparing this method to CT scanning. Results: In both of the methods we did not find any patient with syndesmosis malreduction. Hence, the sensitivity of plain radiography was determined 100%. Conclusion: Based on our findings, there is no need to perform CT scanning to evaluate syndesmosis reduction after ankle ORIF in patients with ankle fractures. Plain radiography is sufficient and has satisfactory sensitivity in these patients.

  1. Syndesmotic Malreduction after Ankle ORIF; Is Radiography Sufficient?

    Directory of Open Access Journals (Sweden)

    Alireza Manafi Rasi

    2013-12-01

    Full Text Available Background: Ankle fractures, especially those resulting from external rotation mechanisms are associated with injury to the distal tibiofibular syndesmosis. Some authors have recommended performing CT scanning after open ankle surgery to evaluate the reduction of syndesmosis. In this current study, we aimed to investigate the sensitivity of plain radiography in diagnosing syndesmosis malreduction after open reduction and internal fixation (ORIF in patients with ankle fractures.   Methods: Thirty patients with ankle fractures participated in this prospective study. ORIFs were performed with respect to all of the technical guidelines shown in orthopedic literature for exact syndesmosis reduction, such as fibular length and proper settings. In the operating room, plain radiography was performed in anteroposterior, mortise and lateral views to assess whether syndesmosis was malreduced. If malreduction was detected, the patient was revised. As the gold standard, patients underwent postoperative bilateral CT scanning to investigate the syndesmosis reduction which was then compared to the healthy side. Finally, the sensitivity of plain radiography in the diagnosis of syndesmosis malreduction was determined by comparing this method to CT scanning. Results: In both of the methods we did not find any patient with syndesmosis malreduction. Hence, the sensitivity of plain radiography was determined 100%. Conclusion: Based on our findings, there is no need to perform CT scanning to evaluate syndesmosis reduction after ankle ORIF in patients with ankle fractures. Plain radiography is sufficient and has satisfactory sensitivity in these patients.

  2. The "Propeller" incision for transpalatal advancement pharyngoplasty: a new approach to reduce post-operative oronasal fistulae.

    Science.gov (United States)

    Shine, Neville Patrick; Lewis, Richard Hamilton

    2008-09-01

    To present a new soft tissue approach for transpalatal advancement pharyngoplasty (TPA), the propeller incision, and to compare the rates of post-operative oronasal fistula in those undergoing TPA with the traditional "Gothic Arch" incision described by Woodson and those with the propeller incision. A prospectively maintained adult sleep apnoea surgery database was used to identify those patients undergoing TPA, either alone or in combination with other procedures, for obstructive sleep apnoea syndrome (OSAS) between February 2001 and September 2006 in a tertiary referral centre by a single surgeon (RHL). In addition to the incision used during TPA, patient demographic data, previous surgery of the upper airways, smoking history, pre-operative body mass index, respiratory disturbance index, oxygen saturation index and the occurrence of oronasal fistula post-operatively, were recorded. The propeller incision technique is described. A total of 89 patients who underwent TPA were identified. A total of 49 patients had a "Gothic Arch" incision and 40 had a "Propeller" incision. The two groups of patients were comparable in age, sex, previous tonsillar and uvulopalatopharyngoplasty surgery, smoking histories and pre-operative disease severity. In the "Gothic Arch" group, eight patients (16%) developed oronasal fistulae in the post-operative period versus only one patient (2.5%) in the "Propeller" group. The difference between the two groups was statistically significant (P=0.038, Fisher's exact test). Of the total cases with post-operative oronasal fistula (n=9), only one patient (from the Gothic Arch incision group) required operative closure which was performed under local anesthesia and healed without complication. The propeller incision provides an anatomically sensible axial-based flap that provides adequate access to perform TPA. It is associated with a lower incidence of oronasal fistula and is recommended by the authors.

  3. JRR-3 neutron radiography facility

    International Nuclear Information System (INIS)

    Matsubayashi, M.; Tsuruno, A.

    1992-01-01

    JRR-3 neutron radiography facility consists of thermal neutron radiography facility (TNRF) and cold neutron radiography facility (CNRF). TNRF is installed in JRR-3 reactor building. CNRF is installed in the experimental beam hall adjacent to the reactor building. (author)

  4. Operational auditing versus traditional method: A comparative investigation

    Directory of Open Access Journals (Sweden)

    Reza Tehrani

    2013-06-01

    Full Text Available Operational auditing is one of the management consultancy services whose significance is on the rise day by day. This approach is, clearly, a systematic and methodical process used to evaluate economic savings of financial processes in organizations and the results of the evaluations are reported to interested people along with some comments to improve operational processes. Accordingly, it appears that the proper employment of the existing rationale in operational auditing can be a significant step towards the improvement of financial efficiency in Iranian public and private banking sector. This paper studies the effects of operational auditing on the improvement of economic saving of financial processes in Iranian private banks compared with traditional approaches where the operations are based on financial statements. The population of this survey includes 15 private and public Iranian banks and the proposed study selects 78 branches, randomly. The Cronbach alpha was used to test the reliability a questionnaire employed to collect the needed data in this study. The results obtained by SPSS Software indicated that the reliability of the instrumentsanged between 0.752 and 0.867, suggesting an acceptable level of the reliability for the questionnaire. Besides, content validity was used to confirm the validity of the instrument. The results of the study indicated that the operational auditing as a useful approach influencing the financial efficiency of public and private banks has significantly transformed the traditional thinking in the field of management auditing. The operational auditing has a number of significant advantages including a better method of controlling financial operations within Iranian banks, efficient planning in the future, facilitating efficient, appropriate, and accurate management decision making, and sound evaluation of managers’ financial operations.

  5. Music and the reduction of post-operative pain.

    Science.gov (United States)

    Dunn, Kelly

    The prevention and treatment of post-operative pain, and the promotion of comfort are the challenges facing practitioners working in the recovery room setting. Surgical pain produces autonomic, psychological, immunological and behavioural responses that can delay or inhibit normal healing. Nurses spend more time with patients experiencing pain than any other healthcare professional. Therefore, they are in an ideal position to consider other pain-relieving strategies to complement the analgesics currently used. The studies reviewed cannot prove that music is effective in reducing post-operative pain, because the research methodology in the majority is poor. Patients, experience of listening to music post-operatively was positive, aiding distraction and increasing comfort. This shows the difference between inconsistent results for the objective measures of pain and what the patient is reporting.

  6. The added value of tomosynthesis in endoscopic retrograde cholangiography with radiography for the detection of choledocholithiasis.

    Science.gov (United States)

    Suyama, Yohsuke; Yamada, Yoshitake; Yamaguchi, Hideki; Someya, Gou; Otsuka, Seiji; Murayama, Yoshitami; Shinmoto, Hiroshi; Jinzaki, Masahiro; Ogawa, Kenji

    2018-04-16

    The diagnostic performance of endoscopic retrograde cholangiography (ERC) with radiography is imperfect. We assessed the value of adding tomosynthesis to ERC with radiography for the detection of choledocholithiasis. This study included 102 consecutive patients (choledocholithiasis/non-choledocholithiasis, n = 57/45), who underwent both radiography and tomosynthesis for ERC in the same examination and were not diagnosed with malignancy. The reference standard for the existence of choledocholithiasis was confirmed by endoscopic stone extraction during ERC, intraoperative cholangiography, or follow up with magnetic resonance cholangiopancreatography (n = 78, 11, and 13, respectively). A gastroenterologist and a radiologist independently evaluated the radiographs and the combination of tomosynthesis and radiographic images in a blinded and randomised manner. Receiver operating characteristic analysis was used for statistical analysis. The areas under the receiver operating characteristic curve for combined tomosynthesis and radiography were significantly higher than those for radiography alone for both readers: Reader 1/Reader 2, 0.929/0.956 [95% confidence interval (CI), 0.861-0.965/0.890-0.983) vs 0.803/0.769 (95% confidence interval, 0.707-0.873/0.668-0.846), respectively (p = 0.0047/tomosynthesis to radiography improved the diagnostic performance of ERC for detection of choledocholithiasis. Advances in knowledge: Adding tomosynthesis to radiography improves detection of choledocholithiasis and tomosynthesis images can be obtained easily after radiographs and repeated immediately.

  7. Neutron radiography at the HFR Petten

    International Nuclear Information System (INIS)

    Markgraf, J.F.W.

    1990-03-01

    This report contains the five papers on neutron radiography activities at the Petten High Flux Reactor (HFR) presented at the Third World Conference on Neutron Radiography which was held in May 1989 in Osaka, Japan. In addition, a survey on neutron radiography in Europe for industry and research as presented at the SITEF NDT symposium 1989 on European Advances in Non-Destructive Testing, held in Toulouse/France in October 1989 is included. The papers compiled here are concerned with: the neutron radiography services available in Petten; the experience with and applications of neutron radiography at Petten; image evaluation and analysis techniques at Petten; the practical utilization of nitrocellulose film in neutron radiography in Europe; an introduction into the basic principles of neutron radiography; an overview of the neutron radiography facilities in Europe for industry and research; and a survey of typical applications of neutron radiography in industry, research and sciences. It is the intention of this compilation to provide a comprehensive overview of the present Petten activities and European facilities in this young and promising field of non-destructive testing of materials and components from the nuclear and the non-nuclear industries and research organizations, and from the sciences

  8. [Application of Markov model in post-marketing pharmacoeconomic evaluation of traditional Chinese medicine].

    Science.gov (United States)

    Wang, Xin; Su, Xia; Sun, Wentao; Xie, Yanming; Wang, Yongyan

    2011-10-01

    In post-marketing study of traditional Chinese medicine (TCM), pharmacoeconomic evaluation has an important applied significance. However, the economic literatures of TCM have been unable to fully and accurately reflect the unique overall outcomes of treatment with TCM. For the special nature of TCM itself, we recommend that Markov model could be introduced into post-marketing pharmacoeconomic evaluation of TCM, and also explore the feasibility of model application. Markov model can extrapolate the study time horizon, suit with effectiveness indicators of TCM, and provide measurable comprehensive outcome. In addition, Markov model can promote the development of TCM quality of life scale and the methodology of post-marketing pharmacoeconomic evaluation.

  9. Digital radiography: description and user's guide

    International Nuclear Information System (INIS)

    Berthel, A.; Bonin, Th.; Cadilhon, S.; Thiery, Ch.; Chatellier, L.; Kaftandjian, V.; Honorat, Ph.; Torrent, J.; Le Brun, A.; Maglaive, J.C.; Moreau, Ph.; Pettier, J.L.; Rebuffel, V.; Roenelle, P.; Roussilhe, J.; Staat, St.; Tahon, M.

    2007-01-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  10. Student Incivility in Radiography Education.

    Science.gov (United States)

    Clark, Kevin R

    2017-07-01

    To examine student incivility in radiography classrooms by exploring the prevalence of uncivil behaviors along with the classroom management strategies educators use to manage and prevent classroom disruptions. A survey was designed to collect data on the severity and frequency of uncivil student behaviors, classroom management strategies used to address minor and major behavioral issues, and techniques to prevent student incivility. The participants were educators in radiography programs accredited by the Joint Review Committee on Education in Radiologic Technology. Findings indicated that severe uncivil student behaviors in radiography classrooms do not occur as often as behaviors classified as less severe. Radiography educators in this study used a variety of strategies and techniques to manage and prevent student incivility; however, radiography educators who received formal training in classroom management reported fewer incidents of student incivility than those who had not received formal training. The participants in this study took a proactive approach to addressing severe behavioral issues in the classroom. Many radiography educators transition from the clinical environment to the classroom setting with little to no formal training in classroom management. Radiography educators are encouraged to attend formal training sessions to learn how to manage the higher education classroom effectively. Student incivility is present in radiography classrooms. This study provides a foundation for future research on incivility. ©2017 American Society of Radiologic Technologists.

  11. Neutron radiography

    International Nuclear Information System (INIS)

    Alaa eldin, M.T.

    2011-01-01

    The digital processing of the neutron radiography images gives the possibility for data quantification. In this case an exact relation between the measured neutron attenuation and the real macroscopic attenuation coefficient for every point of the sample is required. The assumption that the attenuation of the neutron beam through the sample is exponential is valid only in an ideal case where a monochromatic beam, non scattering sample and non background contribution are assumed. In the real case these conditions are not fulfilled and in dependence on the sample material we have more or less deviation from the exponential attenuation law. Because of the high scattering cross-sections of hydrogen (σs=80.26 barn) for thermal neutrons, the problem with the scattered neutrons at quantitative radiography investigations of hydrogenous materials (as PE, Oil, H 2 O, etc) is not trivial. For these strong scattering materials the neutron beam attenuation is no longer exponential and a dependence of the macroscopic attenuation coefficient on the material thickness and on the distance between the sample and the detector appears. When quantitative radiography (2 D) or tomography investigations (3 D) are performed, some image correction procedures for a description of the scattering effect are required. This thesis presents a method that can be used to enhance the neutron radiography image for objects with high scattering materials like hydrogen, carbon and other light materials. This method uses the Monte Carlo code, MCNP5, to simulate the neutron radiography process and get the flux distribution for each pixel of the image and determine the scattered neutrons distribution that causes the image blur and then subtract it from the initial image to improve its quality.

  12. Progress and status of neutron radiography and gauging in Europe

    International Nuclear Information System (INIS)

    Balasko, Marton

    1996-01-01

    European neutron radiography (NR) stations, applications and main trends of progress are surveyed. NR laboratories installed at research reactors operating in eight countries. DIANE transportable neutron source has been constructed within the framework of EURECA project. High resolution film techniques and video imaging are used in various applications. In several cases NR is combined with other non-destructive methods. The European Neutron Radiography Working Group organizes annual meetings and international projects (COST, INCO Copernicus) to promote personal contacts and scientific cooperation in this field. (author)

  13. Radiological safety aspects of industrial radiography

    International Nuclear Information System (INIS)

    Hanekom, A.P.

    1983-01-01

    Industrial radiography and especially gamma-radiography, has established itself as a very powerful tool in non-destructive testing. Unfortunately there is an amount of risk attached to the use of industrial radiography. The primary causes of radiography accidents include: working conditions, equipment failure and lack of supervisory control. To alleviate the radiological risks involved with gamma-radiography, the Atomic Energy Corporation (AEC) has imposed various conditions for the possession, use, and conveyance of radioactive material. This includes personnel training and equipment specifications

  14. Urinary tract infections and post-operative fever in percutaneous nephrolithotomy

    NARCIS (Netherlands)

    Gutierrez, Jorge; Smith, Arthur; Geavlete, Petrisor; Shah, Hemendra; Kural, Ali Riza; de Sio, Marco; Amón Sesmero, José H.; Hoznek, András; de la Rosette, Jean

    2013-01-01

    To review the incidence of UTIs, post-operative fever, and risk factors for post-operative fever in PCNL patients. Between 2007 and 2009, consecutive PCNL patients were enrolled from 96 centers participating in the PCNL Global Study. Only data from patients with pre-operative urine samples and who

  15. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  16. Enhancement of digital radiography image quality using a convolutional neural network.

    Science.gov (United States)

    Sun, Yuewen; Li, Litao; Cong, Peng; Wang, Zhentao; Guo, Xiaojing

    2017-01-01

    Digital radiography system is widely used for noninvasive security check and medical imaging examination. However, the system has a limitation of lower image quality in spatial resolution and signal to noise ratio. In this study, we explored whether the image quality acquired by the digital radiography system can be improved with a modified convolutional neural network to generate high-resolution images with reduced noise from the original low-quality images. The experiment evaluated on a test dataset, which contains 5 X-ray images, showed that the proposed method outperformed the traditional methods (i.e., bicubic interpolation and 3D block-matching approach) as measured by peak signal to noise ratio (PSNR) about 1.3 dB while kept highly efficient processing time within one second. Experimental results demonstrated that a residual to residual (RTR) convolutional neural network remarkably improved the image quality of object structural details by increasing the image resolution and reducing image noise. Thus, this study indicated that applying this RTR convolutional neural network system was useful to improve image quality acquired by the digital radiography system.

  17. Neutron radiography

    International Nuclear Information System (INIS)

    Bayon, G.

    1989-01-01

    Neutronography or neutron radiography, a non-destructive test method which is similar in its principle to conventional X-ray photography, presently occupies a marginal position among non-destructive test methods (NDT) (no source of suitable performance or cost). Neutron radiography associated with the ORPHEE reactor permits industrial testing; it can very quickly meet a cost requirement comparable to that of conventional test methods. In 1988, 2500 parts were tested on this unit [fr

  18. Industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    This Health and Safety Executive Information Sheet on industrial radiography aims to inform directors and managers of industrial radiography companies on the safety precautions necessary to ensure that their personnel do not exceed dose guidelines for exposure to ionizing radiation. The Ionising Radiations Regulations 1985 (IRR85) require that exposure doses for radiographers are kept as low reasonably practicable. Equipment maintenance, and the employment of proper emergency procedures will help to ensure personnel safety. (UK)

  19. Post-operative sleep disturbance: causes, factors and effects on outcome

    DEFF Research Database (Denmark)

    Rosenberg, J; Rosenberg-Adamsen, S; Kehlet, H

    1995-01-01

    Post-operative sleep disturbance, with suppression of rapid eye movement sleep and slow wave sleep followed by a subsequent rebound, seems to be related to the magnitude of trauma and thereby to the surgical stress response. In this context, cortisol, autonomic stimulation, and certain cytokines...... may lead to abnormal sleep. Furthermore, the environment, pain and the administration of analgesics seem to be important factors in the precipitation of sleep abnormalities. Post-operative sleep disturbance may contribute to the development of episodic hypoxaemia, haemodynamic instability and altered...... mental status, all of which have an influence on post-operative morbidity and mortality. Prevention or reduction of the post-operative sleep disturbance may be achieved by minimizing surgical trauma, changing the conventional nursing procedures, avoiding opioids and treating pain with non...

  20. Diagnostic and interventional radiology in the post-operative period and follow-up of patients after rectal resection with coloanal anastomosis

    International Nuclear Information System (INIS)

    Severini, A.; Civelli, E.M.; Uslenghi, E.; Cozzi, G.; Salvetti, M.; Milella, M.; Gallino, G.; Bonfanti, G.; Belli, F.; Leo, E.

    2000-01-01

    Surgical treatment of carcinoma of the distal third of the rectum with anal sphincter preservation is increasingly used in accredited cancer centers. This study aimed to evaluate the diagnostic usefulness of radiological investigations in the management of patients who had undergone resection with coloanal anastomosis for carcinoma of the rectum, in the immediate post-operative period, during closure of the protective colostomy and in the follow-up of symptomatic recanalized patients. A total of 175 patients who had undergone total rectal resection with end-to-side anastomosis for carcinoma of the distal third of the rectal ampulla, most of whom had received postoperative radiotherapy, were evaluated radiologically. In the postoperative period radiological investigation was ordered only for symptomatic patients to detect pathology of the anastomosis and the pouch sutures and was used direct film abdominal radiography and contrast-enhanced radiography of the rectal stump with a water-soluble radio-opaque agent. Before closure of the colostomy, 2 months after rectal excision or approximately 4 months after if postoperative radiotherapy was given, the anastomosis and pouch of all patients, even asymptomatic ones, were studied with water-soluble contrast enema to check for normal canalization. In the follow-up after recanalization radiological examinations were done to complete the study of the large intestine if the endoscopist was not able to examine it up to the cecum. Of the 175 patients examined radiologically during the postoperative period and/or subsequent follow-up, 95 showed no pathological findings. Seventy-nine patients had fistulas of the coloanal anastomosis or the pouch, 23 of which supplied a presacral collection. In the absence of severe sepsis, the only therapeutic measures were systemic antibiotics and washing of the surgical catheters to maintain efficient operation. In 2 patients in whom transanal drainage was performed radiologically the fistula

  1. Diagnostic and interventional radiology in the post-operative period and follow-up of patients after rectal resection with coloanal anastomosis

    Energy Technology Data Exchange (ETDEWEB)

    Severini, A.; Civelli, E.M.; Uslenghi, E.; Cozzi, G.; Salvetti, M.; Milella, M. [Department of Radiology, National Cancer Institute of Milan, via Venezian 1, I-23100 Milan (Italy); Gallino, G.; Bonfanti, G.; Belli, F.; Leo, E. [Department of Surgery, National Cancer Institute of Milan, via Venezian 1, I-23100 Milan (Italy)

    2000-07-01

    Surgical treatment of carcinoma of the distal third of the rectum with anal sphincter preservation is increasingly used in accredited cancer centers. This study aimed to evaluate the diagnostic usefulness of radiological investigations in the management of patients who had undergone resection with coloanal anastomosis for carcinoma of the rectum, in the immediate post-operative period, during closure of the protective colostomy and in the follow-up of symptomatic recanalized patients. A total of 175 patients who had undergone total rectal resection with end-to-side anastomosis for carcinoma of the distal third of the rectal ampulla, most of whom had received postoperative radiotherapy, were evaluated radiologically. In the postoperative period radiological investigation was ordered only for symptomatic patients to detect pathology of the anastomosis and the pouch sutures and was used direct film abdominal radiography and contrast-enhanced radiography of the rectal stump with a water-soluble radio-opaque agent. Before closure of the colostomy, 2 months after rectal excision or approximately 4 months after if postoperative radiotherapy was given, the anastomosis and pouch of all patients, even asymptomatic ones, were studied with water-soluble contrast enema to check for normal canalization. In the follow-up after recanalization radiological examinations were done to complete the study of the large intestine if the endoscopist was not able to examine it up to the cecum. Of the 175 patients examined radiologically during the postoperative period and/or subsequent follow-up, 95 showed no pathological findings. Seventy-nine patients had fistulas of the coloanal anastomosis or the pouch, 23 of which supplied a presacral collection. In the absence of severe sepsis, the only therapeutic measures were systemic antibiotics and washing of the surgical catheters to maintain efficient operation. In 2 patients in whom transanal drainage was performed radiologically the fistula

  2. Combining technologies - radiography and neutron based - for cargo security applications

    International Nuclear Information System (INIS)

    Gozani, T.; Liu, F.; Sivakumar, M.; Brown, D.

    2004-01-01

    Inspection of air and sea cargo has traditionally been done by X-ray systems of various energies relying on operators to analyze images looking for anomalies in the image of cargo that may signify a threat. This has shown only limited success in detecting explosives and other threats, which do not have any distinctive shapes. OSI Systems, through its subsidiaries Rapiscan and Ancore, has combined high-energy x-ray radiography with thermal neutron analysis (TNA) to create the combined system-''TNX''. The system provides automatic material specific detection of bulk threat items, like explosives, while furnishing the operator with a high-resolution image for weapons detection and also to identify anomalies for the TNA to inspect. Similarly the Pulsed Fast Neutron Analysis (PFNA) can be combined with high-energy x-ray to create a ''FNX'' system for both air and sea cargo applications. This enables the operator obtain a three dimensional image of the material composition of the cargo under inspection and remove the clutter from the image leaving only the potentially hazardous material(s) automatically while viewing a high resolution image for manifest verification and weapons. The current status of the technology will be discussed and data be presented

  3. Clinical target volume delineation in glioblastomas: pre-operative versus post-operative/pre-radiotherapy MRI

    Science.gov (United States)

    Farace, P; Giri, M G; Meliadò, G; Amelio, D; Widesott, L; Ricciardi, G K; Dall'Oglio, S; Rizzotti, A; Sbarbati, A; Beltramello, A; Maluta, S; Amichetti, M

    2011-01-01

    Objectives Delineation of clinical target volume (CTV) is still controversial in glioblastomas. In order to assess the differences in volume and shape of the radiotherapy target, the use of pre-operative vs post-operative/pre-radiotherapy T1 and T2 weighted MRI was compared. Methods 4 CTVs were delineated in 24 patients pre-operatively and post-operatively using T1 contrast-enhanced (T1PRECTV and T1POSTCTV) and T2 weighted images (T2PRECTV and T2POSTCTV). Pre-operative MRI examinations were performed the day before surgery, whereas post-operative examinations were acquired 1 month after surgery and before chemoradiation. A concordance index (CI) was defined as the ratio between the overlapping and composite volumes. Results The volumes of T1PRECTV and T1POSTCTV were not statistically different (248 ± 88 vs 254 ± 101), although volume differences >100 cm3 were observed in 6 out of 24 patients. A marked increase due to tumour progression was shown in three patients. Three patients showed a decrease because of a reduced mass effect. A significant reduction occurred between pre-operative and post-operative T2 volumes (139 ± 68 vs 78 ± 59). Lack of concordance was observed between T1PRECTV and T1POSTCTV (CI = 0.67 ± 0.09), T2PRECTV and T2POSTCTV (CI = 0.39 ± 0.20) and comparing the portion of the T1PRECTV and T1POSTCTV not covered by that defined on T2PRECTV images (CI = 0.45 ± 0.16 and 0.44 ± 0.17, respectively). Conclusion Using T2 MRI, huge variations can be observed in peritumoural oedema, which are probably due to steroid treatment. Using T1 MRI, brain shifts after surgery and possible progressive enhancing lesions produce substantial differences in CTVs. Our data support the use of post-operative/pre-radiotherapy T1 weighted MRI for planning purposes. PMID:21045069

  4. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  5. Nuclear Malaysia Plasma Focus Device as a X-ray Source For Radiography Applications

    International Nuclear Information System (INIS)

    Rokiah Mohd Sabri; Abdul Halim Baijan; Siti Aiasah Hashim; Mohd Rizal Mohd Chulan; Wah, L.K.; Mukhlis Mokhtar; Azaman Ahmad; Rosli Che Ros

    2013-01-01

    A 3.375 kJ plasma focus is designed to operate at 13.5 kV for the purpose of studying x-ray source for radiography in Argon discharge. X-rays is detected by using x-ray film from the mammography radiographic plate. The feasibility of the plasma focus as a high intensity flash x-ray source for good contrast in radiography image is presented. (author)

  6. Real-time radiography

    International Nuclear Information System (INIS)

    Bossi, R.H.; Oien, C.T.

    1981-01-01

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components

  7. A mobile-device based applications software for industrial gamma radiography

    International Nuclear Information System (INIS)

    Acharya, Rajesh V.; Mitra, Anant; Kumar, Saroj; Lakshminarayana, Y.; Walinjkar, Parag; Kumar, Umesh

    2013-12-01

    The paper discusses a mobile device based application software for performing calculations required in industrial film radiography using radioisotope sources. The application enables the user to find residual life of a radioactive source, saving multiple source details in the phone memory, exposure time calculation required in gamma radiography and running multiple countdown clocks for accurate and convenient counting of exposure time. The application is also able to provide vibrating and audio alarms when the countdown finishes, automatic SMS facility to multiple users informing details of low activity sources in custody and cordon-off distances for open-source radiography. The application has been developed to work under Android, I-phone (Apple), Blackberry (RIM), Windows, Symbian operating systems and J2ME enabled feature phones. A simplified version of this application with limited features runs on java enabled low-cost mobile phones and tablets. (author)

  8. Intramodality and intermodality agreement in radiography and computed tomography of equine distal limb fractures.

    Science.gov (United States)

    Crijns, C P; Martens, A; Bergman, H-J; van der Veen, H; Duchateau, L; van Bree, H J J; Gielen, I M V L

    2014-01-01

    Computed tomography (CT) is increasingly accessible in equine referral hospitals. To document the level of agreement within and between radiography and CT in characterising equine distal limb fractures. Retrospective descriptive study. Images from horses that underwent radiographic and CT evaluation for suspected distal limb fractures were reviewed, including 27 horses and 3 negative controls. Using Cohen's kappa and weighted kappa analysis, the level of agreement among 4 observers for a predefined set of diagnostic characteristics for radiography and CT separately and for the level of agreement between the 2 imaging modalities were documented. Both CT and radiography had very good intramodality agreement in identifying fractures, but intermodality agreement was lower. There was good intermodality and intramodality agreement for anatomical localisation and the identification of fracture displacement. Agreement for articular involvement, fracture comminution and fracture fragment number was towards the lower limit of good agreement. There was poor to fair intermodality agreement regarding fracture orientation, fracture width and coalescing cracks; intramodality agreement was higher for CT than for radiography for these features. Further studies, including comparisons with surgical and/or post mortem findings, are required to determine the sensitivity and specificity of CT and radiography in the diagnosis and characterisation of equine distal limb fractures. © 2013 EVJ Ltd.

  9. [Taking evaluation of post-marketing as point of cut-in to promote systematic research of traditional Chinese medicine].

    Science.gov (United States)

    Wang, Yong-yan; Wang, Zhi-fei; Xie, Yan-ming

    2014-09-01

    Research on post-marketing Chinese medicine should be the systematic study from application to mechanism. Clinical evaluation is the basis of mechanism study, we can find the clue from clinical evaluation, then make a mechanism study to find the reason, then apply the results to clinic. So it is a virtuous circle. In order to achieve it, we cannot be limited to traditional Chinese medicine, we should form multi-disciplinary team under the direction of grand science thinking, try hard to put industry-university-research institute collaboration association to use, and if necessary, explore the new model of the whole nation system. An appropriate operation mechanism is very important.

  10. Radiography using californium-252 neutron sources

    International Nuclear Information System (INIS)

    Ray, J.W.

    1975-01-01

    The current status in the technology of neutron radiography using californium-252 neutron sources is summarized. Major emphasis is on thermal neutron radiography since it has the widest potential applicability at the present time. Attention is given to four major factors which affect the quality and useability of thermal neutron radiography: source neutron thermalization, neutron beam extraction geometry, neutron collimator dimensions, and neutron imaging methods. Each of these factors has a major effect on the quality of the radiographs which are obtained from a californium source neutron radiography system and the exposure times required to obtain the radiographs; radiograph quality and exposure time in turn affect the practicality of neutron radiography for specific nondestructive inspection applications. A brief discussion of fast neutron radiography using californium-252 neutron sources is also included. (U.S.)

  11. Dental radiography

    International Nuclear Information System (INIS)

    Shekhdar, J.

    1993-01-01

    Dental radiography must comply with the same regulations with which conventional radiography complies. Radiation doses to individual patients are low but, because of the large number of patients X-rayed, the collective dose to the population is not negligible. Care in siting and regular maintenance of the equipment will reduce doses to both staff and patients. To produce X-ray films with a good image quality using a low radiation dose requires attention to film processing; this is often a neglected area. (Author)

  12. Double beam neutron radiography facility

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-09-01

    The DR1 reactor at Risoe is used as a neutron source for neutron radiography. In the double-beam neutron radiography facility a neutron flux of an intensity of 1.4 and 1.8 x 10 6 n. cm -2 . s -1 reaches the object to be radiographed. The transport and exposure container used for neutron radiography of irradiated nuclear fuel rods is described, and the exposure technique and procedure are reviewed. The mode by which single neutron radiographs are assembled and assessed is described. This report will be published in the ''Neutron Radiography Newsletter''. (author)

  13. [Post-operative analgesia in case of ano-rectal diseases].

    Science.gov (United States)

    Rossitto, Maurizio; Pantè, Sebastiano; Manfrè, Antonino; Ciccolo, Antonio

    2009-01-01

    The aim of the study was that to evaluate the post-operative pain in case of ano-rectal diseases wether treated by ketorolac, or buprenorphine or tramadol. The intensity of post-operative pain was evaluated in 60 patients with hemorrhoidal diseases, fistulae, abscesses and anal neoplasms, divided into three homogenous groups and treated with intramuscular ketorolac (Group I), transdermal buprenorphine (Group II) and tramadol in elastomeric pump (Group III). The average index of the visual analogue scale, as mean to evaluate the intensity of the post-operative pain, was 1,85 in the first group, 1,20 in the second one and 1,40 in the third group. In patients treated with transdermal buprenorphine or with tramadol in elastomeric pump there has been a more quick psycho-physical recovery than in those treated with ketorolac; the management of elastomeric pump represents however for patients cause of concern while the transdermal system is a kind of rational and comfortable way of treatment of the pain, with the advantage of being non-invasive. Better compliance and lower operating costs have given the preference to the use of transdermal buprenorphine for the treatment of diseases of the post-operative pain in the diseases of the anal canal.

  14. Preserving traditional medical knowledge through modes of transmission: A post-positivist enquiry

    Directory of Open Access Journals (Sweden)

    Janet Adekannbi

    2014-11-01

    Objectives: This study investigated the role which the mode of transmission plays in the preservation of traditional medical knowledge. Method: A post-positivist methodology was adopted. A purposive sampling technique was used to select three communities from each of the six states in South-Western Nigeria. The snowball technique was used in selecting 228 traditional medical practitioners, whilst convenience sampling was adopted in selecting 529 apprentices and 120 children who were not learning the profession. A questionnaire with a five-point Likert scale, key-informant interviews and focus-group discussions were used to collect data. The quantitative data was analysed using descriptive statistics whilst qualitative data was analysed thematically. Results: The dominant mode of knowledge transmission was found to be oblique (66.5% whilst vertical transmission (29.3% and horizontal transmission (4.2% occurred much less. Conclusion: Traditional medical knowledge is at risk of being lost in the study area because most of the apprentices were children from other parents, whereas most traditional medical practitioners preferred to transmit knowledge only to their children.

  15. Association between elevated pre-operative glycosylated hemoglobin and post-operative infections after non-emergent surgery

    OpenAIRE

    Blankush, Joseph M.; Leitman, I. Michael; Soleiman, Aron; Tran, Trung

    2016-01-01

    Background: A chronic state of impaired glucose metabolism affects multiple components of the immune system, possibly leading to an increased incidence of post-operative infections. Such infections increase morbidity, length of stay, and overall cost. This study evaluates the correlation between elevated pre-operative glycosylated hemoglobin (HbA1c) and post-operative infections. Study design: Adult patients undergoing non-emergent procedures across all surgical subspecialties from January...

  16. Radiological security for industrial radiography

    International Nuclear Information System (INIS)

    Montoya G, Manuel.

    1985-04-01

    This report comprises the basic notions of nucleonics, simple calculations for point sources, X-rays, calculations for coatings, standards for radiation protection and industrial radiography instruments. The preceding sums up with the biological effects of ionizing radiation. This is a guide for people who wish to pass examinations, to get the license for radiological safety, for operators on gamma-graphic sources, which work in the country. It is a requirement for work with this kind of radioactive sources

  17. Magnification radiography

    International Nuclear Information System (INIS)

    Genant, H.K.; Resnick, D.

    1988-01-01

    The relative clinical value of magnification compared with conventional radiography for skeletal applications is presented qualitatively. The presentation is based on the authors' experience with over 25,000 cases in which magnification has been used. For most areas in which magnification (optical or geometric) proves useful, subtle abnormalities of clinical importance are present at bone surfaces or at host-lesion interfaces. This is particularly true for arthritis and metabolic and infectious disorders of bone. In additional instances, serial assessment of the progression of disease or its response to therapy is enhanced by magnification. When gross abnormalities are present, as in most instances of trauma and bone dysplasia, the findings are obvious on conventional radiography, and magnification is not necessary. Thus, the magnification techniques appear to provide important diagnostic information, depending upon the anatomic part that is studied and the clinical question that is posed. It is also apparent that the demonstration of subtle skeletal abnormalities to clinical colleagues for educational purposes is greatly enhanced by magnification radiography

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray ( ... leg (shin), ankle or foot. top of page What are some common uses of the procedure? A ...

  19. Social management in traditional, industrial and post-industrial society: the prospects for management systems development

    Directory of Open Access Journals (Sweden)

    V S Mukhametzhanova

    2010-09-01

    Full Text Available The article is devoted to social management development at different stages of society's evolution - traditional, industrial and post-industrial. The historical types of social management are highlighted.

  20. Choice reaction time in patients with post-operative cognitive dysfunction

    DEFF Research Database (Denmark)

    Steinmetz, J.; Rasmussen, L.S.

    2008-01-01

    BACKGROUND: Post-operative cognitive dysfunction (POCD) is detected by administration of a neuropsychological test battery. Reaction time testing is at present not included as a standard test. Choice reaction time (CRT) data from the first International Study of Post-operative Cognitive Dysfunction...... in nine countries. CRT was measured 52 times using the four boxes test. Patients performed the test before surgery (n=1083), at 1 week (n=926) and at 3 months (n=852) post-operatively. CRT for the individual patient was determined as the median time of correct responses. The usefulness of the CRT...... had a significantly longer CRT. ROC curves revealed that a reaction time of 813 ms was the most appropriate cut-off at 1 week and 762 ms at 3 months but the positive predictive value for POCD was low: 34.4% and 14.7%, respectively. CONCLUSIONS: Post-operative cognitive dysfunction is associated...

  1. What Drive the Damage to Post-Merger Operating Performance?

    Directory of Open Access Journals (Sweden)

    Soegiharto Soegiharto

    2010-05-01

    Full Text Available This study examines whether bidders’ post-merger operat-ing performance are affected by their CEO behavior, premiumspaid to the target firms, the period of mergers, the method ofpayment, the industry of merged firms, capital liquidity, andtheir pre-merger operating performance. Testing the U.S. suc-cessful merger and acquisition data for the period of 1990s, thisstudy finds that in-wave mergers, intra-industry mergers, thepayment of lower premiums, and better pre-merger operatingperformance drive the bidders to produce better post-mergeroperating performance. Three measures of CEO behavior—themain predictor scrutinezed in this study—are proposed andexamined, and the results demonstrate that the effects of thesemeasures on post-merger operating performance are mixed,suggesting that each of the behavioral measures designed in thisstudy may capture CEO behavior in different ways. Keywords: capital liquidity; CEO overconfidence; merger waves, method of pay-ment operating performance

  2. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    International Nuclear Information System (INIS)

    Lee, Wan; Lee, Byung Do

    2003-01-01

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  3. Transitioning to digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, F., E-mail: Francisco.Miranda@pwc.ca [Pratt & Whitney Canada, Longueuil, Quebec (Canada)

    2015-09-15

    This article provides insight on the technical and business considerations necessary to implement or to transition to digital radiography Continued refinements in digital radiography technology have resulted in significant improvements in image quality and detectability of indications. These improvements have resulted in the acceptance of the technology by users and aerospace primes for final product inspection and disposition. Digital radiography has also been identified as an interesting cost reduction initiative with the potential of providing gains in productivity through increased throughput and decreased inspection lead-times and resulting costs. (author)

  4. Recent developments in radiography

    International Nuclear Information System (INIS)

    Berger, Harold

    1982-01-01

    Advances in radiography are reviewed and eighty-one references are cited to provide additional information. The review includes information on x-ray sources in terms of output, portability and imaging geometry and detectors in terms of films and screens, electrostatic methods, real-time techniques and solid state devices. Inspection methods utilizing radiations other than x-rays, neutrons and charged particles, expand the inspection problems suitable for radiography. Techniques such as tomography, digital radiography and image enhancement are described. Tomography, in particular, provides excellent capability to characterize materials and discontinuities

  5. Comparison of the effect of pre- and post-operative physical therapy versus post-operative physical therapy alone on pain and recovery of function after total knee arthroplasty

    OpenAIRE

    Alghadir, Ahmad; Iqbal, Zaheen Ahmed; Anwer, Shahnawaz

    2016-01-01

    [Purpose] The aim of the present study was to compare the effect of pre-operative and post-operative physical therapy versus post-operative physical therapy alone on pain and recovery of function after total knee arthroplasty. [Subjects and Methods] Fifty patients (18 males and 32 females) ranging in age from 48 to 80?years (mean 63.28, SD 9.44) participated in a 6-week two-arm randomized rater-blinded trial. One group received pre- and post-operative physical therapy whereas the other group ...

  6. Neutron radiography and other NDE tests of main rotor helicopter blades

    International Nuclear Information System (INIS)

    Beer, F.C. de; Coetzer, M.; Fendeis, D.; Silva, A. da Costa E

    2004-01-01

    A few nondestructive examination (NDE) techniques are extensively being used worldwide to investigate aircraft structures for all types of defects. The detection of corrosion and delaminations, which are believed to be the major initiators of defects leading to aircraft structural failures, are addressed by various NDE techniques. In a combined investigation by means of visual inspection, X-ray radiography and shearography on helicopter main rotor blades, neutron radiography (NRad) at SAFARI-1 research reactor operated by Necsa, was performed to introduce this form of NDE testing to the South African aviation industry to be evaluated for applicability. The results of the shearography, visual inspection and NRad techniques are compared in this paper. The main features and advantages of neutron radiography, within the framework of these investigations, will be highlighted

  7. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  8. neutron radiography. Report prepared from contributions by members of the MOD Working Party on Neutron Radiography

    International Nuclear Information System (INIS)

    Halmshaw, R.

    1977-03-01

    Radiography with thermal or cold neutrons has some special advantages over X-rays and gamma rays, and some facilities for neutron radiography exist in the Ministry of Defence. This report gives a brief and simple description of the technique, its advantages and disadvantages, and is illustrated with a number of Ordnance applications taken from MOD work, to show examples where neutron radiographs provided extra important information not available from X- or gamma radiography. The facilities available in the UK for neutron radiography are listed. (author)

  9. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  10. Prediction of post-operative pain after a laparoscopic tubal ligation procedure

    DEFF Research Database (Denmark)

    Rudin, A.; Wolner-Hanssen, P.; Hellbom, M.

    2008-01-01

    ligation procedure. METHODS: Assessments of anxiety, mood, psychological vulnerability and pre-operative pain were made before surgery using the State-Trait Anxiety Inventory (STAI), the Hospital Anxiety Depression Scale (HADS), a psychological vulnerability test and the Short-Form McGill Pain......BACKGROUND: Pre-operative identification of reliable predictors of post-operative pain may lead to improved pain management strategies. We investigated the correlation between pre-operative pain, psychometric variables, response to heat stimuli and post-operative pain following a laparoscopic tubal...... Questionnaire (SF-MPQ), respectively. Pre-operative assessments of thermal thresholds and pain response to randomized series of heat stimuli (1 s, 44-48 degrees C) were made with quantitative sensory testing technique. Post-operative pain intensity was evaluated daily by a visual analogue scale during rest...

  11. Development of fast neutron radiography system based on portable neutron generator

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Chia Jia, E-mail: gei-i-kani@hotmail.com; Nilsuwankosit, Sunchai, E-mail: sunchai.n@chula.ac.th [Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Phayathai Rd., Patumwan, Bangkok, THAILAND 10330 (Thailand)

    2016-01-22

    Due to the high installation cost, the safety concern and the immobility of the research reactors, the neutron radiography system based on portable neutron generator is proposed. Since the neutrons generated from a portable neutron generator are mostly the fast neutrons, the system is emphasized on using the fast neutrons for the purpose of conducting the radiography. In order to suppress the influence of X-ray produced by the neutron generator, a combination of a shielding material sandwiched between two identical imaging plates is used. A binary XOR operation is then applied for combining the information from the imaging plates. The raw images obtained confirm that the X-ray really has a large effect and that XOR operation can help enhance the effect of the neutrons.

  12. Selenium-based digital radiography of the cervical spine. Comparison with screen-film radiography for the depiction of anatomic details

    International Nuclear Information System (INIS)

    Ludwig, K.; Diederich, S.; Wormanns, D.; Link, T.M.; Lenzen, H.; Heindel, W.

    2002-01-01

    Purpose: To compare selenium-based digital radiography with conventional screen-film radiography of the cervical spine. Materials and Methods: In a prospective study X-ray images of the cervical spine were obtained in 25 patients using selenium-based digital radiography and conventional screen-film radiography. All images were clinically indicated. Selenium-based digital radiography and conventional screen-film radiography were used in a randomized order. Four radiologists independently evaluated all 50 examinations for the visibility of 76 anatomic details according to a five-level confidence scale (1=not visible, 5=very good visibility). From the evaluation of these anatomic details scores for the upper and middle cervical spine, the cervicothoracic junction and the cervical soft tissues were calculated. The scores for selenium-based digital radiography and conventional screen-film radiography were compared using Wilcoxon's signed rank test. Results: From a total of 15,200 observations (608 per patient) the following scores were calculated for selenium-based digital radiography and for screen-film radiography, respectively: Upper cervical spine 3.88 and 3.94; middle cervical spine 4.60 and 4.48; cervico-thoracic junction 3.64 and 2.62; cervical soft tissue 4.47 and 3.46. The differences between the last two scores were statistically significant (p [de

  13. Urinary tract infections and post-operative fever in percutaneous nephrolithotomy

    DEFF Research Database (Denmark)

    Gutierrez, Jorge; Smith, Arthur; Geavlete, Petrisor

    2013-01-01

    PURPOSE: To review the incidence of UTIs, post-operative fever, and risk factors for post-operative fever in PCNL patients. MATERIALS AND METHODS: Between 2007 and 2009, consecutive PCNL patients were enrolled from 96 centers participating in the PCNL Global Study. Only data from patients with pre...

  14. Radioisotopes - their applications in industrial radiography

    International Nuclear Information System (INIS)

    Rao, H.R.S.

    1977-01-01

    The nature of radioisotopes and their industrial applications with special reference to industrial radiography are outlined. The various aspects of industrial radiography such as source size, source containers, films, density of radiography, radiographic quality and applications are discussed in brief. (M.G.B.)

  15. Accelerated H-LBP-based edge extraction method for digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, Shuang; Zhao, Chen-yi; Huang, Ji-peng [School of Physics, Northeast Normal University, Changchun 130024 (China); Sun, Jia-ning, E-mail: sunjn118@nenu.edu.cn [School of Mathematics and Statistics, Northeast Normal University, Changchun 130024 (China)

    2015-01-11

    With the goal of achieving real time and efficient edge extraction for digital radiography, an accelerated H-LBP-based edge extraction method (AH-LBP) is presented in this paper by improving the existing framework of local binary pattern with the H function (H-LBP). Since the proposed method avoids computationally expensive operations with no loss of quality, it possesses much lower computational complexity than H-LBP. Experimental results on real radiographies show desirable performance of our method. - Highlights: • An accelerated H-LBP method for edge extraction on digital radiography is proposed. • The novel AH-LBP relies on numerical analysis of the existing H-LBP method. • Aiming at accelerating, H-LBP is reformulated as a direct binary processing. • AH-LBP provides the same edge extraction result as H-LBP does. • AH-LBP has low computational complexity satisfying real time requirements.

  16. Estimation of efficiency of new local rehabilitation method at the early post-operative period after dental implantation

    Directory of Open Access Journals (Sweden)

    A. V. Pasechnik

    2017-01-01

      Summary Despite of success of dental implantation, there are often complications at the early post-operative period of implant placing associated with wound damage and aseptic inflammation. Purpose of the work is studying clinical efficiency of combined local application of new mucosal gel “Apior” and magnetotherapy at the early post-operative period after dental implantation. Combined local application of the mucosal gel “Apior” and pulsating low-frequency electromagnetic field in the complex medical treatment of patients after conducting an operation of setting dental implants favourably affects the common state of patients and clinical symptoms of inflammation in the area of operating wound. As compared with patients who had traditional anti-inflammatory therapy, the patients treated with local application of apigel and magnetoterapy had decline of edema incidence, of gingival mucosa hyperemia, of discomfort in the area of conducted operation. There occurred more rapid improvement of inflammation painfulness, which correlated with the improvement of hygienic state of oral cavity and promoted to prevention of bacterial content of damaged mucous surfaces. Estimation of microvasculatory blood stream by the method of ultrasonic doppler flowmetry revealed more rapid normalization of volume and linear high systole speed of blood stream in the periimplant tissues in case of use of new complex local rehabilitation method, that testified to the less pronounced inflammation of oral mucosa after the operation. The authors came to conclusion that the local application of the offered method of medical treatment of early post-operative complications of dental implantation reduces terms of renewal of structural-functional integrity of oral mucosa, helps in preventing development of inflammatory complications and strengthening endosseus implant. The inclusion in the treatment management of a new combined method of application of mucosal gel “Apior” and

  17. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron......In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  18. National audit of post-operative management in spinal surgery

    Directory of Open Access Journals (Sweden)

    Dicken Ben

    2006-05-01

    Full Text Available Abstract Background There is some evidence from a Cochrane review that rehabilitation following spinal surgery may be beneficial. Methods We conducted a survey of current post-operative practice amongst spinal surgeons in the United Kingdom in 2002 to determine whether such interventions are being included routinely in the post-operative management of spinal patients. The survey included all surgeons who were members of either the British Association of Spinal Surgeons (BASS or the Society for Back Pain Research. Data on the characteristics of each surgeon and his or her current pattern of practice and post-operative care were collected via a reply-paid postal questionnaire. Results Usable responses were provided by 57% of the 89 surgeons included in the survey. Most surgeons (79% had a routine post-operative management regime, but only 35% had a written set of instructions that they gave to their patients concerning this. Over half (55% of surgeons do not send their patients for any physiotherapy after discharge, with an average of less than two sessions of treatment organised by those that refer for physiotherapy at all. Restrictions on lifting, sitting and driving showed considerable inconsistency both between surgeons and also within the recommendations given by individual surgeons. Conclusion Demonstrable inconsistencies within and between spinal surgeons in their approaches to post-operative management can be interpreted as evidence of continuing and significant uncertainty across the sub-speciality as to what does constitute best care in these areas of practice. Conducting further large, rigorous, randomised controlled trials would be the best method for obtaining definitive answers to these questions.

  19. Fracture healing: direct magnification versus conventional radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Kessler, T.; Lange, T.; Overbeck, J.; Fiebich, M.; Peters, P.E.

    1994-01-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients' follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ''inter-observer analysis'' was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  20. First experience with digital radiography

    International Nuclear Information System (INIS)

    Buchmann, F.

    1987-01-01

    The digital radiogram is explained, its advantages being the various possibilities of image processing, loss-free transmission, recording and storage capabilities, and in special cases, prompt availability of processed images. Digital subtraction angiography (DSA) and the high-resolution method of digital, luminescent radiography, which replaced the conventional film-foil radiography, are explained as the first developments for the introduction of digital radiography, which today already is an applicable technique. (orig./MG) [de

  1. Efficacy of post-operative radiotherapy in the treatment of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Api, P; Corcione, S; Magnoni, G

    1985-01-01

    A clinical evaluation regarding the efficacy of post-operative radiotherapy in 294 patients with breast cancer is presented. In the author's opinion post-operative radiotherapy is fundamental in the treatment of this tumor. 21 refs.

  2. Problems associated with digital luminescence radiography in the neonate and young infant. Problems with digital radiography.

    Science.gov (United States)

    Arthur, R J; Pease, J N

    1992-01-01

    An evaluation of the Siemens Digiscan has been undertaken to determine whether digital luminescence radiography (DLR) could replace conventional radiography in the examination of the neonate and young infant. Whilst the overall image quality of the digital radiograph was consistently higher than for conventional radiography the difference was less marked than we had expected. Furthermore, the potential for reduction in radiation dose by reducing the repeat rate due to incorrect exposure was limited. The potential advantages of DLR have been critically examined in relationship to neonatal radiography and a number of problems encountered during the evaluation have been highlighted.

  3. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Science.gov (United States)

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  4. Plain abdominal radiography: A powerful tool to prognosticate outcome in patients with zinc phosphide poisoning

    International Nuclear Information System (INIS)

    Hassanian-Moghaddam, H.; Shahnazi, Makhtoom; Zamani, N.; Rahimi, M.; Bahrami-Motlagh, H.; Amiri, H.

    2014-01-01

    Aim: To evaluate the clinical features of zinc phosphide poisoning and to investigate whether outcome could be prognosticated based on abdominal radiography on presentation. Materials and methods: All zinc phosphide-poisoned patients who were referred to Loghman-Hakim Hospital between March 2011 and September 2013 were retrospectively reviewed. Data regarding patients' demographic characteristics, characteristics of the poisoning, abdominal radiography results, and patients' outcome were recorded. Results: In 102 patients, the most common presenting signs/symptoms were nausea and vomiting (60%). Four patients died and another seven had developed complications during their hospitalization (metabolic acidosis, liver abnormalities, or acute renal failure). Nineteen patients had radio-opaque abdominal radiographs, nine of whom had died or developed complications (p = 0.001). Plain abdominal radiography had a sensitivity and specificity of 81% and 89% in predicting the patients' death or further development of complications. The positive and negative predictive values were 47% and 97%, respectively. Conclusion: Plain abdominal radiography is a very good tool for prognostication in patients with zinc phosphide poisoning. Immediate abdominal radiography can help stratify patients into high- or low-risk groups and determine treatment strategies. - Highlights: • ZP poisoning may cause severe symptoms or death although less frequent compared to ALP. • ZP-poisoned patients may deteriorate within the first 72 hours post-ingestion. • Abdominal radiography is a good tool to predict death/complications in these patients

  5. Neutron-induced alpha radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2008-01-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the α - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 μm in thickness can be inspected with a spatial resolution of 32 μm. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to β, γ, X-ray and visible light. (author)

  6. Neutron radiography inspection of investment castings

    International Nuclear Information System (INIS)

    Richards, W.J.; Barrett, J.R.; Springgate, M.E.; Shields, K.C.

    2004-01-01

    Investment casting, also known as the lost wax process, is a manufacturing method employed to produce near net shape metal articles. Traditionally, investment casting has been used to produce structural titanium castings for aero-engine applications with wall thickness less than 1 in (2.54 cm). Recently, airframe manufacturers have been exploring the use of titanium investment casting to replace components traditionally produced from forgings. Use of titanium investment castings for these applications reduces weight, cost, lead time, and part count. Recently, the investment casting process has been selected to produce fracture critical structural titanium airframe components. These airframe components have pushed the traditional inspection techniques to their physical limits due to cross sections on the order of 3 in (7.6 cm). To overcome these inspection limitations, a process incorporating neutron radiography (n-ray) has been developed. In this process, the facecoat of the investment casting mold material contains a cocalcined mixture of yttrium oxide and gadolinium oxide. The presence of the gadolinium oxide, allows for neutron radiographic imaging (and eventual removal and repair) of mold facecoat inclusions that remain within these thick cross sectional castings. Probability of detection (POD) studies have shown a 3x improvement of detecting a 0.050x0.007 in 2 (1.270x0.178 mm 2 ) inclusion of this cocalcined material using n-ray techniques when compared to the POD using traditional X-ray techniques. Further, it has been shown that this n-ray compatible mold facecoat material produces titanium castings of equal metallurgical quality when compared to the traditional materials. Since investment castings can be very large and heavy, the neutron radiography facilities at the University of California, Davis McClellan Nuclear Radiation Center (UCD/MNRC) were used to develop the inspection techniques. The UCD/MNRC has very unique facilities that can handle large parts

  7. Neutron radiography of Apollo ordnance

    International Nuclear Information System (INIS)

    Golliher, K.G.

    1983-01-01

    Neutron radiography played an important role in the successful Apollo missions. Neutron radiography was used, for the first time, on a production basis to examine the internal details of ordnance devices employed in the Apollo Program. Ordnance devices ranged from charges which separated the massive booster stages to those which triggered the release of re-entry parachutes. Discussed are the early developments in neutron radiography and the conversion of this infant nondestructive technology into production capabilities. (Auth.)

  8. Cement technique for reducing post-operative bursitis after trochanteric fixation.

    Science.gov (United States)

    Derman, Peter B; Horneff, John G; Kamath, Atul F; Garino, Jonathan

    2013-02-01

    Post-operative trochanteric bursitis is a known complication secondary to the surgical approach in total hip arthroplasty. This phenomenon may be partially attributable to repetitive microtrauma generated when soft tissues rub against implanted hardware. Significant rates of post-operative trochanteric bursitis have been observed following procedures in which a trochanteric fixation device, such as a bolt-washer mechanism or a cable-grip/claw system, is used to secure the trochanteric fragment after trochanteric osteotomy. We present a simple technique for use with a bolt-washer system or grip plate in which trochanteric components are covered in bone wax followed by a layer of cement to decrease friction and to diminish the risk of post-operative bursitis.

  9. Proton radiography using highpower femtosecond laser

    International Nuclear Information System (INIS)

    Choi, Chang Il

    2010-08-01

    A femtosecond laser emits pulses whose width is between few and few hundreds femtoseconds (10 -15 s). The production mechanism of the high energy protons generated by the femtosecond laser is not clear so far, but the technologies have been improving. The applications using the generated protons are the proton therapy, proton radiography, nuclear physics, security inspection, and so on. Especially in the radiography, the laser-generated protons are very useful to obtain high quality images of thin objects, because protons are able to penetrate an object following an almost straight path and give a depth distribution information of various elements in a subject. Since the laser-driven protons require lower cost and smaller facility than accelerator-based protons, the radiography using laser-driven protons have been of interest. In this research, we have performed the radiography experiments by using protons generated by the 100 TW titanium sapphire femtosecond laser facility of Advanced Photonics Research Institute (APRI) of Gwangju Institute of Science Technology (GIST). A CR-39 Solid State Nuclear Track Detector (SSNTD) has been used as radiography screen. The radiography digital images have been obtained by using an optical microscope and a CCD camera. Modulation Transfer Function (MTF) has been derived from analyzing the obtained images, and the spatial resolution of the images have been evaluated. And, we have performed the radiography experiments of monoenergetic proton from the Tandem Van de Graaff accelerator of Korea Institute of Geoscience and Mineral Resources (KIGAM). We have obtained and compared the radiography images from other proton production methods which are the laser and the accelerator, respectively. And also, we have found out the optimized chemical etching condition, in order to improve the spatial resolution of the radiography images. Finally, the evaluated maximum spatial resolution of the images are 2.09 μm

  10. Image Acquisition and Quality in Digital Radiography.

    Science.gov (United States)

    Alexander, Shannon

    2016-09-01

    Medical imaging has undergone dramatic changes and technological breakthroughs since the introduction of digital radiography. This article presents information on the development of digital radiography and types of digital radiography systems. Aspects of image quality and radiation exposure control are highlighted as well. In addition, the article includes related workplace changes and medicolegal considerations in the digital radiography environment. ©2016 American Society of Radiologic Technologists.

  11. Development of ''SonialvisionSafireII'' system with a new digital radiography device

    International Nuclear Information System (INIS)

    Sano, Takayuki; Okumura, Takeshi; Sakai, Takihito; Fujiwara, Masashi; Toyoda, Toshihide

    2007-01-01

    We released the world's first X-TV system equipped with a 17 inch direct conversion type flat panel X-ray detector (FPD) ''Safire'' in an radiofrequency (RF) table in 2004. Our latest X-TV system, called SonialvisionSafireII, incorporates the digital radiography device and the high voltage generator both of which were newly developed to take better advantage of the characteristics of the FPD. The following are the features of the latest system: Image acquisition and processing with the original matrix of FPD (up to 2880 x 2880 matrix with a 17-inch field of view (FOV)), High-speed radiography in serial acquisition mode (up to 15 fps) and tomosynthesis acquisition mode (up to 30 fps), Operationally improved digital radiography device using a general-purpose personal computer. (author)

  12. Alcohol Consumption Increases Post-Operative Infection but Not Mortality

    DEFF Research Database (Denmark)

    Shabanzadeh, Daniel Mønsted; Sørensen, Lars Tue

    2015-01-01

    BACKGROUND: Alcohol consumption causes multiple comorbidities with potentially negative outcome after operations. The aims are to study the association between alcohol consumption and post-operative non-surgical site infections and mortality and to determine the impact of peri-operative...... alcohol consumption and mortality was found. Meta-analyses of RCTs showed that interventions reduce infections but not mortality in patients with alcohol abuse. CONCLUSIONS: Consumption of more than two units of alcohol per day increases post-operative non-surgical site infections. Alcohol...... for observational studies and RCTs. RESULTS: Thirteen observational studies and five RCTs were identified. Meta-analyses of observational studies showed more infections in those consuming more than two units of alcohol per day compared with drinking less in both unadjusted and adjusted data. No association between...

  13. Hepatobiliary transporter expression and post-operative jaundice in patients undergoing partial hepatectomy.

    Science.gov (United States)

    Bernhardt, Gerwin A; Zollner, Gernot; Cerwenka, Herwig; Kornprat, Peter; Fickert, Peter; Bacher, Heinz; Werkgartner, Georg; Müller, Gabriele; Zatloukal, Kurt; Mischinger, Hans-Jörg; Trauner, Michael

    2012-01-01

    Post-operative hyperbilirubinaemia in patients undergoing liver resections is associated with high morbidity and mortality. Apart from different known factors responsible for the development of post-operative jaundice, little is known about the role of hepatobiliary transport systems in the pathogenesis of post-operative jaundice in humans after liver resection. Two liver tissue samples were taken from 14 patients undergoing liver resection before and after Pringle manoeuvre. Patients were retrospectively divided into two groups according to post-operative bilirubin serum levels. The two groups were analysed comparing the results of hepatobiliary transporter [Na-taurocholate cotransporter (NTCP); multidrug resistance gene/phospholipid export pump(MDR3); bile salt export pump (BSEP); canalicular bile salt export pump (MRP2)], heat shock protein 70 (HSP70) expression as well as the results of routinely taken post-operative liver chemistry tests. Patients with low post-operative bilirubin had lower levels of NTCP, MDR3 and BSEP mRNA compared to those with high bilirubin after Pringle manoeuvre. HSP70 levels were significantly higher after ischaemia-reperfusion (IR) injury in both groups resulting in 4.5-fold median increase. Baseline median mRNA expression of all four transporters prior to Pringle manoeuvre tended to be lower in the low bilirubin group whereas expression of HSP70 was higher in the low bilirubin group compared to the high bilirubin group. Higher mRNA levels of HSP70 in the low bilirubin group could indicate a possible protective effect of high HSP70 levels against IR injury. Although the exact role of hepatobiliary transport systems in the development of post-operative hyper bilirubinemia is not yet completely understood, this study provides new insights into the molecular aspects of post-operative jaundice after liver surgery. © 2011 John Wiley & Sons A/S.

  14. Routine check and annual maintenance for industrial radiography gamma projector

    International Nuclear Information System (INIS)

    Shaharudin Sayuti; Abdul Nassir Ibrahim; Sukhri Ahmad; Arshad Yassin; Mohd Junaidi Jaapar; Khairul Anuar Mohd Salleh; Abdul Razak Hamzah

    2009-04-01

    The main objective of this paper is to share some experience pertaining to gamma projector maintenance programme. In Malaysia there are more than 100 gamma projectors, which need to be maintenance annually. Most of these projectors are Tech-Ops 660 series portable gamma radiography systems, which are used primarily for industrial radiography. The portability feature of the system provides both a safe means of transporting the radioactive source and operating flexibility, particularly useful in areas where access is limited. Generally, the national authorised service centre carries out the annual inspection of this system. In Malaysia, Malaysian Nuclear Agency has been recognised as the National Gamma Projector Maintenance Centre by the Atomic Energy Licensing Board (AELB). In this paper, a brief review of the design and operation is included in the discussion of the maintenance procedure, limitations and improvements of the gamma projector maintenance programme. (author)

  15. The 10 recommendations for prevention of radiation accidents in industrial gamma radiography

    International Nuclear Information System (INIS)

    Souza, Luana Silva de

    2015-01-01

    The Industrial Gamma Radiography, as part of Industrial Radiography, stands out as the most widespread and plays an important role in the quality control of different materials and devices. However, IAEA classifies industrial gamma radiography in the Category 2 as very dangerous due to the radiological risk caused by the use of high activity radioactive sources. In March, 2012, a Brazilian Workshop on Prevention of Industrial Gamma Radiography Accident was performed by DIAPI/CNEN with the objective of disseminating knowledge about radiological accidents with radioactive sources in this application. During this Workshop, IRD/CNEN conducted a survey with 75 participants using a form with 22 recommendations to prevent radiological accidents, aiming to select the most voted. This present work aims to perform a detailed statistical study to define the Top 10 Recommendations for industrial gamma radiography operator avoids radiological accidents and to prepare a brochure with these top 10 recommendations to be distributed to all industrial gamma radiography radiation workers. Data analysis was performed using the statistical method 'Frequency Distribution', among the 75 participants categorized as General, RPO, and Other Workers of the area. The results were obtained for each category, accounting for the total of 22 recommendations in its percentage and number of votes, and the top 10 recommendations were defined to prevent radiological accidents. The first place and most important recommendation is 'Always use a personal alarm monitor throughout the work'. One of the conclusions is that the brochure with the Top 10 Recommendations shows to be understandable and useful for dissemination and training of radiation workers to avoid radiological accidents in industrial gamma radiography. (author)

  16. Comparison of the efficacy of conventional radiography, digital radiography, and ultrasound in diagnosing periapical lesions.

    Science.gov (United States)

    Raghav, Namita; Reddy, Sujatha S; Giridhar, A G; Murthy, Srinivas; Yashodha Devi, B K; Santana, N; Rakesh, N; Kaushik, Atul

    2010-09-01

    The aim of this study was to evaluate the efficacy of conventional radiography, digital radiography and ultrasound imaging in diagnosing periapical lesions. Twenty-one patients aged between 15 and 45 years with well defined periapical radiolucency associated with anterior maxillary or mandibular teeth requiring endodontic surgery or extraction were selected and consented to the study. Preoperative intraoral periapical radiographs and digital images using charge-coupled device obtained by paralleling technique were assessed by 3 specialist observers who gave their diagnosis of the periapical lesions. Then ultrasound examination was performed and the images were assessed for size, contents, and vascular supply by 3 ultrasonographers. It was followed by curettage of periapical tissues to enable histopathologic investigation, which is the gold standard in diagnosis. The data were statistically analyzed using SPSS, analysis of variance, and kappa statistics. The percentage accuracy of diagnosing periapical lesions using conventional radiography was 47.6%, digital radiography 55.6%, and ultrasound 95.2%. Ultrasound had the highest sensitivity and specificity: 0.95 and 1.00, respectively. Conventional and digital radiography enable diagnosis of periapical diseases, but not their nature, whereas ultrasound provides accurate information on the pathologic nature of the lesions, which is of importance in predicting the treatment outcome. Therefore ultrasound can be used as an adjunct to conventional or digital radiography in diagnosing periapical lesions. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  17. Accidents in industrial radiography and lessons to be learned. A review of IAEA Safety Report

    International Nuclear Information System (INIS)

    Modupe, M.S.; Oresegun, O.

    1998-01-01

    This IAEA Safety Report Series publication is the result of a review of a large selection of accidents in industrial radiography which Regulatory Authorities, professional associations and scientific journals have reported. The review's objective was to draw lessons from the initiating events of the accidents, contributing factors and the consequences. A small, representative selection of accident descriptions is used to illustrate the primary causes of radiography accidents and a set of recommendations to prevent recurrence of such accidents or to mitigate the consequences of those that do occur is provided. By far the most common primary cause of over-exposure was 'Failure to follow operational procedures' and specifically failure to perform radiation monitoring to locate the position of the source. The information in the Safety Report is intended for use by Regulatory Authorities, operating organizations, workers manufacturers and client organizations having responsibilities for radiation protection and safety in industrial radiography. (author)

  18. Post-operative pain treatment in Denmark from 2000 to 2009

    DEFF Research Database (Denmark)

    Nielsen, P R; Christensen, P A; Meyhoff, C S

    2012-01-01

    In Denmark, the first acute pain service (APS) was introduced in 1993. An important objective became to facilitate implementation of accelerated post-operative rehabilitation programmes (ACC) in selected procedures in abdominal, gynaecological and orthopaedic surgery. Therefore......, it is of considerable interest to study the association between the developments of post-operative pain management and the ACC by sequential analyses from 2000 to 2009....

  19. Neutron radiography by using JSW baby cyclotron

    International Nuclear Information System (INIS)

    Toda, Yojiro

    1995-01-01

    At present, JSW baby cyclotrons are mostly used for the production of the radioisotopes for medical use. The attempt to use this baby cyclotron for neutron radiography began already in 1981. The feasibility of the neutron radiography for the explosives in metallic cases which are used for H1 rockets was investigated. In 1983, it was shown that the neutron radiography by using the baby cyclotron in Muroran Works, Japan Steel Works, Ltd. was able to be carried out as a routine work. Since then, the nondestructive inspection by neutron radiography has been performed for rocket pyrotechnic articles, and contributed to heighten their reliability. Further, the radiography by using fast neutrons was developed and put to practical use for recent large H2 rockets. The JSW baby cyclotron BC 168 which has been used for neutron radiography can accelerate 16 MeV protons or 8 MeV deuterons up to 50 μA. The principle of thermal neutron radiography is the generation of fast neutrons by irradiating a Be target with the proton beam accelerated by a baby cyclotron, the moderation of the fast neutrons, the formation of the thermal neutron flux of uniform distribution with a collimator, the thermal neutron flux hitting the Gd plate in a film cassette through an object, and the exposure of an X-ray film to electrons from the Gd plate. Fast neutron radiography apparatus, and commercial neutron radiography are described. (K.I.)

  20. Radiation protection at industrial radiography in Germany exposures and unusual events

    International Nuclear Information System (INIS)

    Czarwinski, R.; Haeusler, U.; Frasch, G.

    2006-01-01

    In the Federal Republic of Germany safety related events in the use and transportation of radioactive materials as well as in the operation of accelerators are registered. The analysis of these events reveals their causation and allows this conclusions on avoidable errors. In this paper, a special insight is given into events in the field of gamma radiography which is a technical application of ionising radiation for non destructive testing of materials. Conclusions from analysis are drawn. In addition, the occupational radiation exposure of workers is presented taking into account that industrial radiography is performed under particular working conditions with different risks. (orig.)

  1. Pilot prospective study of post-surgery sleep and EEG predictors of post-operative delirium.

    Science.gov (United States)

    Evans, Joanna L; Nadler, Jacob W; Preud'homme, Xavier A; Fang, Eric; Daughtry, Rommie L; Chapman, Joseph B; Attarian, David; Wellman, Samuel; Krystal, Andrew D

    2017-08-01

    Delirium is a common post-operative complication associated with significant costs, morbidity, and mortality. We sought sleep/EEG predictors of delirium present prior to delirium symptoms to facilitate developing and targeting therapies. Continuous EEG data were obtained in 12 patients post-orthopedic surgery from the day of surgery until delirium assessment on post-operative day 2 (POD2). Diminished total sleep time (r=-0.68; pdelirium severity. Patients experiencing delirium slept 2.4h less and took 2h longer to fall asleep. Greater waking EEG delta power (r=0.84; pdelirium severity. Loss of sleep on night1 post-surgery is an early predictor of subsequent delirium. EEG Delta Power alterations in waking and sleep appear to be later indicators of impending delirium. Further work is needed to evaluate reproducibility/generalizability and assess whether sleep loss contributes to causing delirium. This first study to prospectively collect continuous EEG data for an extended period prior to delirium onset identified EEG-derived indices that predict subsequent delirium that could aid in developing and targeting therapies. Copyright © 2017. Published by Elsevier B.V.

  2. New medical application: nuclear scattering radiography

    International Nuclear Information System (INIS)

    Saudinos, J.

    1977-01-01

    Nuclear scattering of 1 GeV protons is used to obtain three dimensional radiographies with a volume resolution of about 1 mm 3 . The information is different from the one given by X-ray radiographies and in particular one may get radiographies of the hydrogen included in objects. Results on a vertebral column and a 'sella turcica' are presented [fr

  3. Radiation Safety in Industrial Radiography. Specific Safety Guide

    International Nuclear Information System (INIS)

    2011-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  4. Workshop on industrial isotope radiography: Programme and lectures

    International Nuclear Information System (INIS)

    1979-01-01

    The booklet contains the texts of lectures delivered in the Workshop on Industrial Radiography held at Bombay during 24-25 July 1979. The lectures cover some topics of relevance to industrial radiography. The topics are radiation protection and legislative aspects in industrial radiography; problems in field radiography in fertilizer industry, petrochemical industry and heavy engineering industry; occupational exposures in industrial radiography; and a review of the progress and recent trends in industrial radiographic techniques and equipment. (M.G.B.)

  5. Digital radiography: description and user's guide

    Energy Technology Data Exchange (ETDEWEB)

    Berthel, A. [Cryospace, 78 - Les Mureaux (France); Bonin, Th. [CEA Valduc, 21 - Is-sur-Tille (France); Cadilhon, S.; Thiery, Ch. [CEA Bruyeres-le-Chatel, 91 (France); Chatellier, L. [Electricite de France (EDF-RD), Recherche et Developpement, 78 - Chatou (France); Kaftandjian, V. [Lyon Univ., INSA Lab. Controle Non Destructif par Rayonnements Ionisants (CNDRI), 69 (France); Honorat, Ph.; Torrent, J. [SNECMA, 75 - Paris (France); Le Brun, A. [Electricite de France, 78 - Chatou (France); Maglaive, J.C. [Euromev, 78 - Buc (France); Moreau, Ph. [General Electric Industrial Inspection Technologies, 69 - Limonest (France); Pettier, J.L. [CEA Cadarach, Dir. de l' Energie Nucleaire, 13 - Saint Paul lez Durance (France); Rebuffel, V. [CEA Grenoble, Lab. d' Electronique et de Technologie de l' Informatique (LETI), 38 (France); Roenelle, P. [Centre d' Etudes Techniques de l' Equipement, 69 - Bron Lyon (France); Roussilhe, J. [Carestream Health France SA, 71 - Chalon/Saone (France); Staat, St.; Tahon, M. [Cegelec, 91 - Bretigny sur Orge (France)

    2007-07-01

    The presented document arises from the work of the group 'Digital Radiography and sensors' of COFREND. It is a collective work of synthesis aimed to analyze the quality parameters of digital images influencing the answer and the diagnosis brought to a given industrial problem. Five families of digital sensors have been studied: 1. Image Intensifier coupled with CCD devices - 2. scintillators coupled with a CCD device- 3. Flat Panels with indirect conversion - 4. Flat Panels with direct electric conversion - 5. Photostimulable Storage Phosphor Screens). In particular, concerning a complete imaging chain, it deals with the notions of magnification, blur (unsharpness) (geometrical, kinetic or internal to the very sensor), noises, scattered radiation, spatial resolution, which is different from the one of analog detectors such as films, Contrast to Noise Ratio (CNR), sensitivity using IQIs, dynamic range, detection quantum efficiency, persistence and temporal resolution. This document is not a standard; it must be understood as a user's guide, and it approaches some essentials corrections to bring to a sensor in order to optimize his efficiency without losing information during the pre-processing phase in the radiographic acquisition. It also introduces some image processing tools commonly used. It can be used as a source document to the future elaboration of a standardisation document. It augurs not at all of the choice of a digital sensor with regard to the traditional radiographic film, but gives bases of reflection to a radio user for a sensible transfer from the classic radiography to the digital radiography. (authors)

  6. Diagnostic radiography: A study in distancing

    International Nuclear Information System (INIS)

    Reeves, Pauline J.; Decker, Sola

    2012-01-01

    Aims: This article aims to explore the ways in which diagnostic radiographers use distancing as a tool for emotional management in radiography practice. Methods: This review utilises data from oral history interviews undertaken as part of a larger study documenting the oral history of the diagnostic radiography profession in the United Kingdom as recounted by 24 participants. Results: The results are presented as illustrative of various aspects of the role of the diagnostic radiographer including the initial choice of diagnostic radiography as a profession, the endemic use of particular terminology, the nature of the encounter in diagnostic radiography (including that of sectional imaging) and whether the role is really patient-centred. Conclusions: The article concludes by suggesting that distancing from the patient is mediated by the need for physical touch in order to position the patient for radiography and also makes the suggestion that those opting for diagnostic radiography as a career may do so because they want a profession which is more distanced from the patient and that, even where this is not the case initially, individuals are socialised into adopting the ‘feeling rules’ of the profession. The article concludes by outlining potential areas for further research.

  7. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  8. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  9. Sevoflurane impairs post-operative olfactory memory but preserves olfactory function.

    Science.gov (United States)

    Kostopanagiotou, Georgia; Kalimeris, Konstantinos; Kesidis, Kyriakos; Matsota, Paraskevi; Dima, Cleanthi; Economou, Maria; Papageorgiou, Charalambos

    2011-01-01

    The effect of anaesthesia on olfaction has not been systematically studied. Our aim is to compare the effects of general and regional anaesthesia on olfactory acuity and memory in the immediate post-operative period. Sixty adult patients with the American Society of Anesthesiologists I and II status scheduled for elective minor surgery were included. Exclusion criteria were smoking, alcoholism, psychiatric disease and recent or past airway infection with resulting hyposmia. Patients were randomly allocated to one of three groups (in the analysis, n = 16 in each group): epidural anaesthesia (group E), general anaesthesia with propofol (group P) and general anaesthesia with sevoflurane (group S) of 40-120 min duration. The evening before surgery, at 0.5 and at 3 h post-operatively olfactory acuity and memory were tested, along with blood sampling to measure plasma melatonin and oxytocin levels. Olfactory acuity was tested with successive dilutions of n-butyl-alcohol, and olfactory memory (interpretation of odours) with the University of Pennsylvania Smell Identification Test. Patient characteristics did not differ between groups. Olfactory acuity was intact in all patients, before and after anaesthesia. Olfactory memory deteriorated in group S compared to groups P and E at both post-operative time-points. This was accompanied by a significant post-operative reduction of plasma melatonin levels in group S. Oxytocin levels remained constant in all groups. Our results manifest a specific effect of sevoflurane on olfactory memory, not observed with neuraxial or total intravenous anaesthesia. The misinterpretation of odours in the immediate post-operative period by sevoflurane could be mediated by the decreased levels of melatonin.

  10. The application of neutron radiography to the measurement of the water-permeability of concrete

    International Nuclear Information System (INIS)

    Mo, Dawei; Zhang, Chaozong; Guo, Zhi-Ping; Liu, Yisi; An, Fulin; Mio, Qitian; Wang, Zhimin; Lian, Huizhen.

    1988-01-01

    The water-permeability of concrete is significant for dam, offshore platform and under-water basement of brindge etc. The traditional measuring method of permeability is the fixed pressure of water method in which the water-permeating process in a concreteblock cannot be measured continuously. Owing to the obvious difference of hydrogen content in the permeated regions of samples and the regions which have not been permeated. A combination of the neutron radiography and traditional method has been used to study continuously the whole process of water permeating. The combined method overcomes some shortages of the traditional methods and helps to gain more informations. (author)

  11. Evaluation of post-operative prophylactic irradiation for carcinoma of the esophagus

    International Nuclear Information System (INIS)

    Mafune, Ken-ichi; Tanaka, Yoichi; Fujita, Kichishiro; Sakura, Mizuyoshi

    1987-01-01

    Of 147 patients with carcinoma of the esophagus resected at Saitama Cancer Center Hospital for 10 years, 98 cases were studied to evaluate post-operative prophylactic irradiation. The total dose of irradiation was up to 4,000 ∼ 5,000 rads of Linac X-ray and the irradiated field was T-shaped covering the upper mediastinal and bilateral cervical regions. The prognosis of the post-operative irradiated group (56 cases) was significantly better than that of the control group (42 cases) (p < 0.01). This study resulted in a five-year survival rate of 34.2 percent for patients in the post-operative irradiated group, compared to 16.7 percent for those in the control group. Further detailed comparative studies revealed similar results. Cancer recurrence occurred at the irradiated fields in 8 cases (14.3 %), though in 15 cases (35.7 %) of the control group. This suggested the local suppressive effect of the post-operative irradiation to the cancer recurrence. (author)

  12. Functioning of industrial radiography services

    International Nuclear Information System (INIS)

    Alves, R.N.; Costa, H.M. da; Bianchini, F.G.; Arrieta, L.A.I.

    1988-12-01

    The objective of this norm is establish the necessary requirements for the functioning of industrial radiography services, as well as the procedures for acquisition and transfer of radioactive sources and/or X-ray equipments used in industrial radiography [pt

  13. [Necessity of applying pharmacovigilance in post-marketing safety monitoring of traditional Chinese medicine injections].

    Science.gov (United States)

    Wang, Hai-Nan; Chen, Wen; Fu, Zheng; Du, Wen-min; He, Jia

    2008-03-01

    Traditional Chinese medicine (TCM) injection has become one of the hotspots in the new TCM research and development. The serious adverse drug reactions happened in clinical have arosed attention widely in the whole society. It's very urgent to monitor the post-marketing safety of TCM injections. This paper elucidated the pharmacovigilance's necessity in the post-marketing safety monitoring of TCM injections, basing on the reason of safety problem of TCM injections and the future developing trend of adverse drug reaction monitoring. Also, this paper introduced the rapid signal detection method of spontaneous reporting system database by data mining technology.

  14. Is peri-operative cortisol secretion related to post-operative cognitive dysfunction?

    NARCIS (Netherlands)

    Rasmussen, L.S.; O'Brien, J.T.; Silverstein, J.H.; Johnson, T.; Siersma, V.D.; Canet, J.; Jolles, J.; Hanning, C.D.; Kuipers, H.M.; Abildstrom, H.; Papaioannou, A.; Raeder, J.; Yli-Hankala, A.; Sneyd, J.R.; Munoz, L.; Moller, J.T.

    2005-01-01

    Background: The pattern of cortisol secretion is influenced by surgery. As cortisol can adversely affect neuronal function, this may be an important factor in the development of post-operative cognitive dysfunction (POCD). We hypothesized that the incidence of POCD would be related to changes in

  15. Are radiography lecturers, leaders?

    International Nuclear Information System (INIS)

    Hendry, Julie Anne

    2013-01-01

    This review article aims to explore the concept of radiography lecturers acting as leaders to their student followers. Through a brief review of the literature, a definition of leadership is suggested and some leadership theories explored. The path-goal theory, leader–member exchange theory and the contemporary theory of transformational leadership are examined more closely. Links between lecturer-leader behaviour and student motivation and learning are tentatively suggested with transformational leadership appearing to offer the optimal leadership style for lecturers to adopt. The paucity of literature relating directly to radiography is acknowledged and areas for further research are suggested. The article concludes with some of the author's practical ideas for incorporating transformational leadership styles and behaviours into radiography education today

  16. Computed radiography in paediatrics

    International Nuclear Information System (INIS)

    Kelly, C.

    1996-01-01

    Computed radiography has also been called storage phosphor technology, digital luminescence radiography and scintillation phosphor technology, since it relies on phosphor imaging plate as an alternative to screen-film. One of the major advantages in the use of computed radiography (CR) is the consistent image quality independence of the radiographer and exposure used. And secondly a marked reduction in the need for repeat films was achieved and thus a decrease in dose to the patient. In some cases, dose was able to be reduced further due to the fact that the plates respond to lower doses and still provide adequate image quality. Digitalising the Cr image allows it to be transmitted to an imaging console. The images can then be stored on optical disc. 7 refs

  17. Industrial radiography techniques and their applications

    International Nuclear Information System (INIS)

    Wamorkar, R.R.

    1981-01-01

    Various aspects of industrial radiography are discussed. These include: radiation sources, geometrical unsharpness of image, radiation attenuation in the specimen, radiation effect of film, types of film, intensifying screens, exposure time calculations, source to film distance and sensivitity. Radiography techniques for examination of welded joints on flat plate and pipes or cylindrical objects, and castings are indicated. Applications of radiography in various industries are mentioned. (M.G.B.)

  18. Vertebral Fracture Assessment in Supine Position : Comparison by Using Conventional Semiquantitative Radiography and Visual Radiography

    NARCIS (Netherlands)

    Hospers, Ilone C.; van der Laan, Johan G.; Zeebregts, Clark J.; Nieboer, Patrick; Wolffenbuttel, Bruce H. R.; Dierckx, Rudi A.; Kreeftenberg, Herman G.; Jager, Pieter L.; Slart, Riemer H. J. A.

    Purpose: To retrospectively evaluate the accuracy of vertebral fracture assessment (VFA) performed with the patient in the supine position and conventional semiquantitative radiography of the spine by using conventional visual radiography of the spine as the reference standard. Materials and

  19. Representation of functions as the Post-Widder inversion operator of generalized functions

    Directory of Open Access Journals (Sweden)

    R. P. Manandhar

    1984-01-01

    Full Text Available A study is made of the Post-Widder inversion operator to a class of generalized functions in the sense of distributional convergence. Necessary and sufficient conditions are proved for a given function to have the representation as the rth operate of the Post-Widder inversion operator of generalized functions. Some representation theorems are also proved. Certain results concerning the testing function space and its dual are established. A fundamental theorem regarding the existence of the real inversion operator (1.6 with r=0 is proved in section 4. A classical inversion theory for the Post-Widder inversion operator with a few other theorems which are fundamental to the representation theory is also developed in this paper.

  20. A Neutron Radiography System for Field Use

    Science.gov (United States)

    1989-06-01

    provoked a major renewal of interest in neutron radiography because it promises to bring neutron radiography to the workplace , a convenience provided...II I~F I C II i IiH i ii MTL TR 89-52 I-AD A NEUTRON RADIOGRAPHY SYSTEM N FOR FIELD USE e~m JOHN J. ANTAL and ALFRED S. MAROTTA, and LOUIS J. FARESE...COVERED A NEUTRON RADIOGRAPHY SYSTEM FOR FIELD USE Final Report 6. PERFORMING OR1. REPORT NUMBER 7. AUTHOR(s) S. CONTRACT OR GRANT NUMBER(s) John J

  1. The role of pre-operative and post-operative glucose control in surgical-site infections and mortality.

    Directory of Open Access Journals (Sweden)

    Christie Y Jeon

    Full Text Available The impact of glucose control on surgical-site infection (SSI and death remains unclear. We examined how pre- and post-operative glucose levels and their variability are associated with the risk of SSI or in-hospital death.This retrospective cohort study employed data on 13,800 hospitalized patients who underwent a surgical procedure at a large referral hospital in New York between 2006 and 2008. Over 20 different sources of electronic data were used to analyze how thirty-day risk of SSI and in-hospital death varies by glucose levels and variability. Maximum pre- and post-operative glucose levels were determined for 72 hours before and after the operation and glucose variability was defined as the coefficient of variation of the glucose measurements. We employed logistic regression to model the risk of SSI or death against glucose variables and the following potential confounders: age, sex, body mass index, duration of operation, diabetes status, procedure classification, physical status, emergency status, and blood transfusion.While association of pre- and post-operative hyperglycemia with SSI were apparent in the crude analysis, multivariate results showed that SSI risk did not vary significantly with glucose levels. On the other hand, in-hospital deaths were associated with pre-operative hypoglycemia (OR = 5.09, 95% CI (1.80, 14.4 and glucose variability (OR = 1.14, 95% CI (1.03, 1.27 for 10% increase in coefficient of variation.In-hospital deaths occurred more often among those with pre-operative hypoglycemia and higher glucose variability. These findings warrant further investigation to determine whether stabilization of glucose and prevention of hypoglycemia could reduce post-operative deaths.

  2. The role of pre-operative and post-operative glucose control in surgical-site infections and mortality.

    Science.gov (United States)

    Jeon, Christie Y; Furuya, E Yoko; Berman, Mitchell F; Larson, Elaine L

    2012-01-01

    The impact of glucose control on surgical-site infection (SSI) and death remains unclear. We examined how pre- and post-operative glucose levels and their variability are associated with the risk of SSI or in-hospital death. This retrospective cohort study employed data on 13,800 hospitalized patients who underwent a surgical procedure at a large referral hospital in New York between 2006 and 2008. Over 20 different sources of electronic data were used to analyze how thirty-day risk of SSI and in-hospital death varies by glucose levels and variability. Maximum pre- and post-operative glucose levels were determined for 72 hours before and after the operation and glucose variability was defined as the coefficient of variation of the glucose measurements. We employed logistic regression to model the risk of SSI or death against glucose variables and the following potential confounders: age, sex, body mass index, duration of operation, diabetes status, procedure classification, physical status, emergency status, and blood transfusion. While association of pre- and post-operative hyperglycemia with SSI were apparent in the crude analysis, multivariate results showed that SSI risk did not vary significantly with glucose levels. On the other hand, in-hospital deaths were associated with pre-operative hypoglycemia (OR = 5.09, 95% CI (1.80, 14.4)) and glucose variability (OR = 1.14, 95% CI (1.03, 1.27) for 10% increase in coefficient of variation). In-hospital deaths occurred more often among those with pre-operative hypoglycemia and higher glucose variability. These findings warrant further investigation to determine whether stabilization of glucose and prevention of hypoglycemia could reduce post-operative deaths.

  3. The application of anatomical side markers during abdominal and IVU examinations: An investigation of practice prior to and post-installation of computed radiography (CR)

    International Nuclear Information System (INIS)

    Platt, Jane M.; Strudwick, Ruth M.

    2009-01-01

    Professionally, radiographers are accountable for their practice. Available literature highlights the ramifications of not using anatomical side markers within the primary beam. It was thought by the authors that the installation of a computed radiography (CR) system could potentially cause a change in practice due to the ease of adding anatomical side markers manually/electronically during post-processing. This study assessed anatomical marker use within the primary beam at a district general hospital in East Anglia, one-year pre-CR installation and one-year post-CR installation. 100 abdominal images were evaluated from each time period and the presence of anatomical side markers was recorded and compared to establish any significant change. The study showed that although there was a decline in use of anatomical side markers used within the primary beam post-CR installation (from 32% to 25%), the changes were not statistically significant (p > 0.05). However, the agreed standard of 100% images having the primary beam side marker present was not met. There is a conflict of opinion about the necessity for anatomical side markers to be used within the primary beam. However, the researchers believe there is a case for recommending alterations and improvements to practice to comply with 'best practice' requirements.

  4. Assessment and validation of CT scanogram to compare per-operative and post-operative mechanical axis after navigated total knee replacement

    Science.gov (United States)

    Jain, Sunil

    2008-01-01

    Our objective was to assess and validate low-dose computed tomography (CT) scanogram as a post-operative imaging modality to measure the mechanical axis after navigated total knee replacement. A prospective study was performed to compare intra-operative and post-operative mechanical axis after navigated total knee replacements. All consecutive patients who underwent navigated total knee replacement between May and December 2006 were included. The intra-operative final axis was recorded, and post-operatively a CT scanogram of lower limbs was performed. The mechanical axis was measured and compared against the intra-operative measurement. There were 15 patients ranging in age from 57 to 80 (average 70) years. The average final intra-operative axis was 0.56° varus (4° varus to 1.5° valgus) and post-operative CT scanogram axis was 0.52° varus (3.1° varus to 1.8° valgus). The average deviation from final axes to CT scanogram axes was 0.12° valgus with a correlation coefficient of 0.9. Our study suggests that CT scanogram is an imaging modality with reasonable accuracy for measuring mechanical axis despite significantly low radiation. It also confirms a high level of correlation between intra-operative and post-operative mechanical axis after navigated total knee replacement. PMID:18696064

  5. Industrial Radiography Safety in Australia

    International Nuclear Information System (INIS)

    Hockings, Colin

    2006-01-01

    400 μSv average for industrial radiographers in a developed country such as the United Kingdom (NRPB 2005), it is less than that reported for a developing country such as Iran (AEOI 2004), which is 1650 μSv. Industrial radiography accidents most frequently occur with radiation devices using sealed sources such as iridium 192 and cobalt 60, and not with x-ray generators. In comparison to other countries, the safety record of industrial radiographers as judged by accident data and dose records, places Australia somewhere between that of an advanced country and a developing one. Many of the investigations into accidents in industrial radiography have revealed that their frequency and severity would have been reduced or even eliminated if the persons involved had been better prepared to use the equipment, and better prepared to deal with accident and incident situations. In Australia, there appears to be scope for improvement and standardisation of training in the use of industrial radiography equipment, and more importantly, in the training for response to possible accidents and incidents. A national standard for radiation safety training and assessment should be developed by a competent organisation such as the Australian Institute for Non-Destructive Testing. It should be incorporated into the Code of Practice or Safety Guide for industrial radiography and adopted by all jurisdictions. The use of a code of safe practice for industrial radiography should continue. The present NH and MRC code is in need of review. Such a review must result in a code and a guideline document which are readily useable by the industry, standardise training in radiation safety, ensure a high level of operational radiation safety and are available for adoption by the various Australian jurisdictions with minimal supplementary local requirements. Copyright (2006) The Australian Institute for Non-Destructive Testing

  6. Gamma radiography and its technological application; Gammagraphie et techniques annexes

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1962-07-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  7. Governing martial traditions: Post-conflict ritual sites in Iron Age Northern Europe (200 BC–AD 200)

    DEFF Research Database (Denmark)

    Løvschal, Mette; Holst, Mads Kähler

    2018-01-01

    -scale conflicts, assembled groups, and high-arousal group behavior. They thus differ from governing structures at community or family group level. This approach gives post-conflict rituals a new and more central role in the development and upholding of ritual traditions across Iron Age Northern Europe.......-conflict ritual sanctuaries of Northern Gaul and the war bogs of Scandinavia, both of which display the remains of violent conflicts with exceptional amounts of (often mutilated) weapon paraphernalia and/or human remains. The purpose of this paper is to examine the linkage between these two traditions...... is explained by the existence of a partly shared symbolic reservoir of symbols and practices. Dependent on differing ritual governance structures, different patterns come about in the archaeological record. In this respect, post-conflict sites represent largely self-organized settings associated with large...

  8. Broadening the radiography spectrum

    International Nuclear Information System (INIS)

    Waswa, L.; Mutwasi, O.; Kioko, J.

    2006-05-01

    The text discuses the mammography in breast screening and evaluation of breast cancer; Small parts ultrasounds at plaza imaging solutions; role of a Radiographer in mammography-new perspective; Medical imaging education in africa; Caring for the paediatric patient as to broaden radiotherapy spectrum; Problems and challenges in care for children undergoing radiotherapy; Paediatric radiotherapy, management and side effects; The principles of pattern recognition of skeletal structures; the place of distance learning education in broadening the radiography spectrum; the curriculum and budgeting image; sonographer's guide; Computed radiography- X-Ray with vision; digital Radiography in Kenya today; Particle Therapy at Ithemba Labs; The role of lung perfusion and ventilation study in the evaluation of the pulmonary embolism and lastly, an overview of Head and neck treatment at Kenyatta National hospital radiotherapy

  9. An evaluation of intra-operative and post-operative blood loss in ...

    African Journals Online (AJOL)

    Background: Total knee replacement is a rewarding and reliable procedure, producing a lasting relief to severe knee pains. However, significant blood loss usually in the post-operative period may be a challenge, necessitating prompt restoration of circulating blood volume to minimize morbidity and mortality. The aim of this ...

  10. Determination, through of thermoluminescence dosimetry, of the incident radiation in critical organs, during cephalometric radiographies

    International Nuclear Information System (INIS)

    Hipolito Junior, O. di; Goncalves, N.; Boscolo, F.N.; Montebelo Filho, A.

    1985-01-01

    The object of this paper was to value and to compare the doses of X-ray incident in critical orgas of patient and operator, during cephalometric radiography. Each patient was submited for two radiographics expositions. First of all, they use the followings factors: 85 kVp, 15 mA and 4/10 s of exposition; while of the second radiography the conditions were of 70 kVp, 15 mA and 1.2 s of exposition. The dosimetric method was the thermoluminescent through the LiF-700. Although the cephalometric radiographies showed similars qualities, in bot conditions where the equipment functioned, the situation of high voltage was noted small doses of radiation. (author) [pt

  11. Human performance analysis of industrial radiography radiation exposure events

    International Nuclear Information System (INIS)

    Reece, W.J.; Hill, S.G.

    1995-01-01

    A set of radiation overexposure event reports were reviewed as part of a program to examine human performance in industrial radiography for the US Nuclear Regulatory Commission. Incident records for a seven year period were retrieved from an event database. Ninety-five exposure events were initially categorized and sorted for further analysis. Descriptive models were applied to a subset of severe overexposure events. Modeling included: (1) operational sequence tables to outline the key human actions and interactions with equipment, (2) human reliability event trees, (3) an application of an information processing failures model, and (4) an extrapolated use of the error influences and effects diagram. Results of the modeling analyses provided insights into the industrial radiography task and suggested areas for further action and study to decrease overexposures

  12. The effect of pre-operative optimization on post-operative outcome in Crohn's disease resections

    DEFF Research Database (Denmark)

    El-Hussuna, Alaa; Iesalnieks, Igors; Horesh, Nir

    2017-01-01

    BACKGROUND: The timing of surgical intervention in Crohn's disease (CD) may depend on pre-operative optimization (PO) which includes different interventions to decrease the risk for unfavourable post-operative outcome. The objective of this study was to investigate the effect of multi-model PO on...

  13. Improving screen-film chest radiography

    International Nuclear Information System (INIS)

    Shaikh, N.; Baker, R.A.

    1996-01-01

    Traditionally symmetric screens and double emulsion symmetric films with medium to wide latitutde are used for radiography of the chest. Beacuse of mismatch of transmitted exposure through the chest with limited latitude of the film, most of the dense areas of the chest are underexposed. Kodak's recent innovation of a unique asymmetry screen-film system (InSight) alleviates this problem. Our phantom measurement indicates that the InSight system offers wider recording range, and the flexible grid permits more positional latitude than conventional grids. Our five-year extensive clinical experience indicates that dense anatomic structures, such as mediastinum, retrocardiac and subdiaphragmatic, are more visible in the InSight system than in the conventional symmetric system. Similarly, a substantial improvement in image quality in portable chest imaging is realized by use of flexible grids because of scatter rejection and invisible grid lines. (author)

  14. Dosimetric evaluation in panoramic and tele-radiography procedures

    International Nuclear Information System (INIS)

    Oliveira, Georgge Gomes

    2004-01-01

    The present work had as an objective to evaluate the skin surface entrance dose in panoramic and tele radiography procedures in three clinics in Recife - Pernambuco - Brazil, and to contribute with data for the determination of reference levels for super cited extra oral procedures, for this purpose, operational conditions in 3 clinics were evaluated in Recife, aiming to evaluate the existence and integrity of the radioprotection equipment, manner and conditions of image processing; and radiographic equipment parameters such as the dimension of the irradiation filed, the total filtration, the exposure time and the potential applied to the X ray tube. For an estimation of the skin entrance dose of the patient, the phantom Randon Alderson and thermoluminescence dosemeters were used. From these values and the conversion factors determined by the Monte Carlo technique, with the phantom MAX it was possible to estimate the dose absorbed in the organ due to the tele radiography procedures. Regarding panoramic radiography the study showed that the more elevated doses occurred in the parotid gland region which is near rotational venters. In the case of tele radiography the highest dose value occurred in the regions corresponding to the temporal lobe of the brain, followed by linfonodes, ears and parotid glands. The doses absorbed in the eyes and the thyroid gland were, 0.037 mGy and 0.002 mGy in Clinic A and 0.062 mGy and 0.003 mGy in Clinic C, respectively. Regarding equipment test, inadequacy was found in the beam collimation in Clinic A and in the reproducibility of the X ray exposure in Clinic C. The total filtration in both clinics was inadequate.(author)

  15. Computational radiology in skeletal radiography

    International Nuclear Information System (INIS)

    Peloschek, Ph.; Nemec, S.; Widhalm, P.; Donner, R.; Birngruber, E.; Thodberg, H.H.; Kainberger, F.; Langs, G.

    2009-01-01

    Recent years have brought rapid developments in computational image analysis in musculo-skeletal radiology. Meanwhile the algorithms have reached a maturity that makes initial clinical use feasible. Applications range from joint space measurement to erosion quantification, and from fracture detection to the assessment of alignment angles. Current results of computational image analysis in radiography are very promising, but some fundamental issues remain to be clarified, among which the definition of the optimal trade off between automatization and operator-dependency, the integration of these tools into clinical work flow and last not least the proof of incremental clinical benefit of these methods.

  16. High energy neutron radiography

    International Nuclear Information System (INIS)

    Gavron, A.; Morley, K.; Morris, C.; Seestrom, S.; Ullmann, J.; Yates, G.; Zumbro, J.

    1996-01-01

    High-energy spallation neutron sources are now being considered in the US and elsewhere as a replacement for neutron beams produced by reactors. High-energy and high intensity neutron beams, produced by unmoderated spallation sources, open potential new vistas of neutron radiography. The authors discuss the basic advantages and disadvantages of high-energy neutron radiography, and consider some experimental results obtained at the Weapons Neutron Research (WNR) facility at Los Alamos

  17. WE-G-209-01: Digital Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, B. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  18. Conversion from film to image plates for transfer method neutron radiography of nuclear fuel

    Energy Technology Data Exchange (ETDEWEB)

    Craft, Aaron E.; Papaioannou, Glen C.; Chichester, David L.; Williams, Walter J.

    2017-02-01

    This paper summarizes efforts to characterize and qualify a computed radiography (CR) system for neutron radiography of irradiated nuclear fuel at Idaho National Laboratory (INL). INL has multiple programs that are actively developing, testing, and evaluating new nuclear fuels. Irradiated fuel experiments are subjected to a number of sequential post-irradiation examination techniques that provide insight into the overall behavior and performance of the fuel. One of the first and most important of these exams is neutron radiography, which provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Results from neutron radiography are often the driver for subsequent examinations of the PIE program. Features of interest that can be evaluated using neutron radiography include irradiation-induced swelling, isotopic and fuel-fragment redistribution, plate deformations, and fuel fracturing. The NRAD currently uses the foil-film transfer technique with film for imaging fuel. INL is pursuing multiple efforts to advance its neutron imaging capabilities for evaluating irradiated fuel and other applications, including conversion from film to CR image plates. Neutron CR is the current state-of-the-art for neutron imaging of highly-radioactive objects. Initial neutron radiographs of various types of nuclear fuel indicate that radiographs can be obtained of comparable image quality currently obtained using film. This paper provides neutron radiographs of representative irradiated fuel pins along with neutron radiographs of standards that informed the qualification of the neutron CR system for routine use. Additionally, this paper includes evaluations of some of the CR scanner parameters and their effects on image quality.

  19. Neutron Focusing Mirrors for Neutron Radiography of Irradiated Nuclear Fuel at Idaho National Laboratory

    Science.gov (United States)

    Rai, Durgesh K.; Wu, Huarui; Abir, Muhammad; Giglio, Jeffrey; Khaykovich, Boris

    Post irradiation examination (PIE) of samples irradiated in nuclear reactors is a challenging but necessary task for the development on novel nuclear power reactors. Idaho National Laboratory (INL) has neutron radiography capabilities, which are especially useful for the PIE of irradiated nuclear fuel. These capabilities are limited due to the extremely high gamma-ray radiation from the irradiated fuel, which precludes the use of standard digital detectors, in turn limiting the ability to do tomography and driving the cost of the measurements. In addition, the small 250 kW Neutron Radiography Reactor (NRAD) provides a relatively weak neutron flux, which leads to low signal-to-noise ratio. In this work, we develop neutron focusing optics suitable for the installation at NRAD. The optics would separate the sample and the detector, potentially allowing for the use of digital radiography detectors, and would provide significant intensity enhancement as well. The optics consist of several coaxial nested Wolter mirrors and is suited for polychromatic thermal neutron radiation. Laboratory Directed Research and Development program of Idaho National Laboratory.

  20. Licensing for industrial gamma and X-ray radiography installation in Peru

    International Nuclear Information System (INIS)

    Medina G, E.

    1988-01-01

    According the regulations for ionizing radiation source installations an application to the Peruvian National Authority should be forwarded in order to get the construction on operation license both industrial gamma and X-ray. Radiography is considered as well as personnel aspects. The proceedings are described

  1. A range of equipment for dental radiography

    International Nuclear Information System (INIS)

    Bergman, G.P.M.; Clement, S.L.

    1980-01-01

    A brief review of the history of dental radiography is followed by a description of the latest Philips equipment, ranging from compact units for intra-oral radiography to advanced systems for panoramic techniques and skull radiography. The advantages of automatic exposure control and automatic film processing are also discussed. In conclusion, some probable future trends are forecast. (Auth.)

  2. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chin-Sheng Tang

    Full Text Available To prevent surgical site infection (SSI, the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH, and carbon dioxide (CO2, suspended particulate matter (PM, and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18% and traumatic surgery room (8%. The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  3. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  4. Imaging of bone tumors: evaluation of direct magnification radiography

    International Nuclear Information System (INIS)

    Link, T.M.; Hillmann, A.; Erlemann, R.; Groenefeld, A.; Haeussler, M.; Heppe, A.E.; Vestring, T.; Peters, P.E.

    1996-01-01

    Objective. To evaluate the potentials of magnification radiography as compared with conventional radiography in diagnosing bone tumors. Design and patients. Sixty-two patients with primary bone tumors and tumorlike lesions underwent radiography with both conventional (non-magnified) and magnification (fivefold) techniques. All radiographs were analyzed by four radiologists and the findings correlated with the histopathology findings. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 μm. Digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Results. The diagnosis of benign and malignant lesions as well as the individual tumor diagnosis were determined with higher accuracy using magnification compared with conventional radiography (88% vs 75% and 71% vs 52%, p<0.01). Margins of destruction, periosteal reactions and matrix patterns were evaluated with higher certainty by all of the radiologists (p<0.01). Conclusion. Magnification radiography may improve the evaluation and diagnosis of bone tumors. (orig.). With 6 tabs

  5. Image Gently: Challenges for radiologic technologists when performing digital radiography in children

    International Nuclear Information System (INIS)

    Goske, Marilyn J.; Smith, Susan N.; Charkot, Ellen; Herrmann, Tracy; John, Susan D.; Mills, Thalia T.; Morrison, Gregory

    2011-01-01

    The development of digital radiography (DR) has provided numerous benefits for pediatric imaging, including the ability to post-process images and to make images immediately available for access by care providers. However, DR presents several significant challenges for the radiologic technologists who are responsible for operating the equipment and producing high-quality images in children. This paper discusses those challenges, including lack of standardization among vendors, particularly with regard to the exposure indicator; lack of pediatric-specific educational materials and pediatric techniques; the need for manual technique instead of the use of automatic exposure control in smaller children; and complications related to field size, collimation and shielding in small children. Specific actions and design modifications that might facilitate the effective management of these challenges will be also described. The implementation of measures to promote the production of optimal images while minimizing radiation exposure requires cooperation and communication among imaging professionals, manufacturers and regulatory agencies. (orig.)

  6. Industrial Radiography | Radiation Protection | US EPA

    Science.gov (United States)

    2017-08-07

    Manufacturers use a method called industrial radiography to check for cracks or flaws in materials. Radiation is used in industrial radiography to show problems not visible from the outside without damaging the material.

  7. Neutron induced electron radiography

    International Nuclear Information System (INIS)

    Andrade, Marcos Leandro Garcia

    2008-01-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 μm in 24 μm of aluminum at a resolution of 32 μm. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  8. Chest radiography after minor chest trauma

    Energy Technology Data Exchange (ETDEWEB)

    Rossen, B.; Laursen, N.O.; Just, S.

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma.

  9. Chest radiography after minor chest trauma

    International Nuclear Information System (INIS)

    Rossen, B.; Laursen, N.O.; Just, S.

    1987-01-01

    The results of chest radiography in 581 patients with blunt minor thoracic trauma were reviewed. Frontal and lateral views of the chest indicated pathology in 72 patients (12.4%). Pneumothorax was present in 16 patients; 4 had hemothorax. The physical examination and the results of chest radiography were not in accordance because in 6(30%) of the 20 patients with hemo/-pneumothorax the physical examination was normal. Consequently there is wide indication for chest radiography after minor blunt chest trauma. (orig.)

  10. Prediction of chronic post-operative pain: pre-operative DNIC testing identifies patients at risk.

    Science.gov (United States)

    Yarnitsky, David; Crispel, Yonathan; Eisenberg, Elon; Granovsky, Yelena; Ben-Nun, Alon; Sprecher, Elliot; Best, Lael-Anson; Granot, Michal

    2008-08-15

    Surgical and medical procedures, mainly those associated with nerve injuries, may lead to chronic persistent pain. Currently, one cannot predict which patients undergoing such procedures are 'at risk' to develop chronic pain. We hypothesized that the endogenous analgesia system is key to determining the pattern of handling noxious events, and therefore testing diffuse noxious inhibitory control (DNIC) will predict susceptibility to develop chronic post-thoracotomy pain (CPTP). Pre-operative psychophysical tests, including DNIC assessment (pain reduction during exposure to another noxious stimulus at remote body area), were conducted in 62 patients, who were followed 29.0+/-16.9 weeks after thoracotomy. Logistic regression revealed that pre-operatively assessed DNIC efficiency and acute post-operative pain intensity were two independent predictors for CPTP. Efficient DNIC predicted lower risk of CPTP, with OR 0.52 (0.33-0.77 95% CI, p=0.0024), i.e., a 10-point numerical pain scale (NPS) reduction halves the chance to develop chronic pain. Higher acute pain intensity indicated OR of 1.80 (1.28-2.77, p=0.0024) predicting nearly a double chance to develop chronic pain for each 10-point increase. The other psychophysical measures, pain thresholds and supra-threshold pain magnitudes, did not predict CPTP. For prediction of acute post-operative pain intensity, DNIC efficiency was not found significant. Effectiveness of the endogenous analgesia system obtained at a pain-free state, therefore, seems to reflect the individual's ability to tackle noxious events, identifying patients 'at risk' to develop post-intervention chronic pain. Applying this diagnostic approach before procedures that might generate pain may allow individually tailored pain prevention and management, which may substantially reduce suffering.

  11. Representability of metastatic bone lesions in magnification radiography

    International Nuclear Information System (INIS)

    Togawa, Takashi

    1981-01-01

    Magnification radiography, bone scintigraphy, and normal roentgenography were performed on patients with malignant tumors to detect their bone metastases, and from the results obtained, these diagnostic procedures were evaluated for the detectability and representability of metastatic bone lesions. Bone scan and normal roentgenography were performed on 90 metastatic bone lesions in 37 patients, and magnification radiography was done on 14 bone lesions noted in 10 of the 37 and another with benign osseous change. Among the three, bone scintigraphy was best, and magnification radiography and normal roentgenography did not differ significantly in detectability. In magnification radiography, some metastatic bone lesions were represented more clearly than by normal roentgeography, but some were not. As regards the representability of the ribs, magnification radiography was very useful. One case of bone destruction was detected by magnification radiography, but not by normal roentgenography. (author)

  12. Process waste assessment for the Radiography Laboratory

    International Nuclear Information System (INIS)

    Phillips, N.M.

    1994-07-01

    This Process Waste Assessment was conducted to evaluate the Radiography Laboratory, located in Building 923. It documents the processes, identifies the hazardous chemical waste streams generated by these processes, recommends possible ways to minimize waste, and serves as a reference for future assessments of this facility. The Radiography Laboratory provides film radiography or radioscopy (electronic imaging) of weapon and nonweapon components. The Radiography Laboratory has six x-ray machines and one gamma ray source. It also has several other sealed beta- and gamma-ray isotope sources of low microcurie (μCi) activity. The photochemical processes generate most of the Radiography Laboratory's routinely generated hazardous waste, and most of that is generated by the DuPont film processor. Because the DuPont film processor generates the most photochemical waste, it was selected for an estimated material balance

  13. Computed radiography for breast cancer

    International Nuclear Information System (INIS)

    Yamada, Tatsuya; Muramatsu, Yukio

    1990-01-01

    In order to evaluate the possibility of using computed radiographic mammography in mass surveys of the breast, we have retrospectively examined 71 breast cancer lesions in 71 patients using computed radiographic and conventional non-screen mammographies and have carried out comparative studies on tumor detection rate and calcification. A 95.8% detection rate was obtained for the tumor image (n 71) using computed radiography (CR) and one of 93.0% using non-screen techniques. Three lesions remained undetected by either study. A 100% detection rate was obtained for calcification associated with cancer (n 33) from each method. No significant differences in either detection rate or calcification were seen between the two images. On the other hand, the ability to recognize tumor images (n 66) was as follows; CR superior to non-screen radiography in 53 lesions (80.3%), equal in eight lesions (12.1%) and inferior in five lesions (7.6%). For the calcification images (n 18), CR was superior to non-screen radiography in all 18 lesions. Obviously, CR gives better results than non-screen radiography. Furthermore, an adequate image can be obtained using CR even although the X-ray dosage is only a twentieth of that required for non-screen radiography. It can therefore be applied not only to mass surveys for breast cancer but also to routine clinical diagnoses. (author)

  14. Spatially coded backscatter radiography

    International Nuclear Information System (INIS)

    Thangavelu, S.; Hussein, E.M.A.

    2007-01-01

    Conventional radiography requires access to two opposite sides of an object, which makes it unsuitable for the inspection of extended and/or thick structures (airframes, bridges, floors etc.). Backscatter imaging can overcome this problem, but the indications obtained are difficult to interpret. This paper applies the coded aperture technique to gamma-ray backscatter-radiography in order to enhance the detectability of flaws. This spatial coding method involves the positioning of a mask with closed and open holes to selectively permit or block the passage of radiation. The obtained coded-aperture indications are then mathematically decoded to detect the presence of anomalies. Indications obtained from Monte Carlo calculations were utilized in this work to simulate radiation scattering measurements. These simulated measurements were used to investigate the applicability of this technique to the detection of flaws by backscatter radiography

  15. Radiography of pressure ulcers

    International Nuclear Information System (INIS)

    Borgstroem, P.S.; Ekberg, O.; Lasson, A.

    1988-01-01

    In patients with longstanding and/or deep pressure ulcers radiology is usually consulted. Survey radiography and sinography in 14 patients with pressure ulcers (6 over the tuber ischii and 8 over the femoral trochanter) were evaluated. Osteomyelitic involvement of adjacent bone was revealed in 9 patients on survey radiography. However, it was usually impossible to assess whether or not bony involvement represents healed or active osteomyelitis. Sinography did not contribute to the assessment of whether or not adjacent cortical bone was involved. However, when a fistulation to an adjacent joint was revealed this contributed substantially to the preoperative planning of resection. We therefore recommend that survey radiography and sinography should be included in the evaluation of these patients but that the results from such examinations are critically evaluated. Joint involvement should be taken seriously as progression of septic arthritis usually occurs rapidly. (orig.)

  16. Effect of Submucosal Injection of Dexamethasone on Post-operative Sequelae of Third Molar Surgery

    Directory of Open Access Journals (Sweden)

    S P Deo

    2011-06-01

    Full Text Available Introduction: This study was carried out to evaluate the effects of a single pre-operative sub-mucosal injection of dexamethasone after third molar surgery to see the effects on post-operative discomfort. Methods: This study was a prospective, double-blind, randomized, clinical trial. The subjects were forty patients who underwent surgical removal of the mandibular impacted third molar under local anesthesia and after being randomly assigned to receive either an 8 mg dexamethasone as submucosal injection or a normal saline injection into the lower buccal vestibule adjacent to the third molar. The maximum interincisal distance and facial contours were measured at the baseline and post-surgically on Day 2 and 7. Post-operative pain was evaluated subjectively using a visual analog scale and objectively by counting the number of analgesic tablets used. All subjects were operated upon by the same investigator to minimize the difference from inter-operator variability. Results: There was a signicant difference in the measurements of the degree of swelling and trismus between the two groups on the 2nd post-operative day. In contrast, there was no statistically signicant difference between the groups on the 7th post-operative day. The test group also used fewer analgesics post-operatively. Conclusions: Submucosal injection of dexamethasone after third molar surgery is effective in reducing postoperative swelling and trismus. It also delays the onset of post-operative pain. Keywords: dexamethasone, submucosal injection, third molar, third molar surgery, third molar extraction

  17. New development of neutron radiography with a small cyclotron

    International Nuclear Information System (INIS)

    Ikeda, Yasushi; Ohkubo, Kohei; Kato, Toshihiko; Nakamura, Tomihisa; Fuji, Takayoshi.

    1990-01-01

    A series of neutron radiography testing has been performed for several years by using a small accelerator called 'Baby Cyclotron' manufactured by Japan Steel Works, Ltd. The Baby Cyclotron produces fast neutrons at the rate of 4x10 12 n/cm 2 s, and enables to perform neutron radiography imaging by various techniques. The most important application of this Baby Cyclotron radiography system is the non-destructive testing (NDT) of various explosive devices prepared for space launch vehicles. It is assured that thermal neutron radiography testing is a very useful means for the NDT. Also fast neutron radiography testing is in progress. The fast neutron radiography with a CR39 track-etch image recorder was developed, and it was shown to be the very useful NDT means when the thicker objects used for new H-2 launch vehicles had to be examined. Because thermal neutron radiography has the high detectability of hydrogenous materials, organic elastomers such as O-rings and explosive powder are clearly observable through the opaque steel walls of containers. The Baby Cyclotron and the neutron radiography facility, thermal neutron and fast neutron radiography testings and so on are reported. (K.I.)

  18. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed. (author)

  19. Examination of welds by digital radiography

    International Nuclear Information System (INIS)

    Ekinci, S.

    2004-01-01

    Full text: Industrial radiography is the oldest and most reliable non-destructive test method in the examination and two dimensional evaluation of weld defects. Digital radiographic methods provide more sensitive, faster and more reliable evaluation of defect images. One of the most important factors influencing the contrast and consequently the image quality is the noise on the film caused by scattered radiation. The digital image processing technique can eliminate the noise and improve the image quality. Digital radiography also enables three dimensional evaluation of weld defects. This work describes the use of digital radiography in the evaluation of defects in welds of different configurations by using a laser film digitizing system and an appropriate software programme. Advantages and limitations of the digital technique and conventional film radiography were discussed

  20. Pre- and post-operative values of serum CRP in patients undergoing surgery for brain tumour

    International Nuclear Information System (INIS)

    Syeda, T.; Rizvi, H.A.; Hashim, A.S.

    2014-01-01

    Objective: To determine the concentration of C-reactive protein in pre- and post-operative serum samples of brain tumour patients in order to detect the potential risks of post-operative infections. Methods: Serum C-reactive protein was measured on pre- and post-operative Day 1, Day 2 and Day 7 in 18 patients who underwent surgery for brain tumours. The study was performed at the Neurosurgical Ward, Jinnah Postgraduate Medical Centre, Karachi, from May 2007 to April 2008. Mean pre-operative patients and control values were compared using Mann-Whitney or Wilcoxon tests for comparing between pre- and post-operative values. P-value was considered significant at 5.0mg/L but no statistically significant difference was found when compared with healthy controls, with mean 4.4+-6.6 and 0.9+-0.7, respectively. Significantly raised serum concentrations were observed in all post-operative samples when compared with pre-operative samples. Serum CRP concentrations significantly increased post-operatively on Day 1, with mean value of 102.9+-82.0mg/L (p<0.0005), and further increased on Day 2 with mean value of 166.9+-128.1mg/L (p<0.0005), but declined on Day 7, with mean value of 42.7+-63.6mg/L (p<0.005). Conclusion: Pre-operative serum C-reactive protein concentrations of 28% of the patients were elevated, suggesting an association with brain tumours. Post-operative serum concentrations were significantly higher than those noted before the surgery. Absence of a fall of concentration from peak value on post-operative Day 2 or a secondary rise from post-operative Day 7 could be alarming for inter-current infection. (author)

  1. Development of tungsten collimators for industrial radiography

    International Nuclear Information System (INIS)

    Varkey, P.A.; Verma, P.B.; Jayakumar, T.K.; Mammachan, M.K.

    2001-01-01

    Collimators are essential components of industrial radiography set up as it provides radiation safety to persons involved in the radiography work. A collimator with optimum design features also helps in reducing the scattered radiation which in turn results in radiographs having better sensitivity. This papers describes the salient design features of the tungsten collimators developed by the BRIT, for industrial radiography. (author)

  2. [Application of nested case-control study on safe evaluation of post-marketing traditional Chinese medicine injection].

    Science.gov (United States)

    Xiao, Ying; Zhao, Yubin; Xie, Yanming

    2011-10-01

    The nested case-control study design (or the case-control in a cohort study) is described here as a new study design used in safe evaluation of post-marketing traditional Chinese medicine injection. In the nested case-control study, cases of a disease that occur in a defined cohort are identified and, for each, a specified number of matched controls is selected from among those in the cohort who have not developed the disease by the time of disease occurrence in the case. For many research questions, the nested case-control design potentially offers impressive reductions in costs and efforts of data collection and analysis compared with the full cohort approach, with relatively minor loss in statistical efficiency. The nested case-control design is particularly advantageous for studies in safe evaluation of post-marketing traditional Chinese medicine injection. Some examples of the application of nested case-control study were given.

  3. Post-Conflict Iraq: If You Don't Know Where You're Going

    National Research Council Canada - National Science Library

    Bussiere, Thomas A

    2007-01-01

    .... Traditionally, post-conflict operations have been seen as separate to major combat operations and pre-conflict preparations by both the military and interagency organizations have been deficient...

  4. Factors associated with the goal commitment of radiography departments' staff in organizational change

    International Nuclear Information System (INIS)

    Groenroos, Eija; Pajukari, Arja; Matinheikki-Kokko, Kaija

    2009-01-01

    Purpose: The aim of the study is to examine factors associated with the goal commitment of radiography departments' staff. The associations studied are (1) organizational change, (2) work-related factors, (3) psychosocial work environment, and (4) intention to leave. Method: The follow-up study was performed between 2005 and 2007 in co-operation with 10 radiography departments of two Finnish municipalities. In 2005 the response rate was 60% (n = 97/163) and in 2007 it was 49% (n = 73/150). Results: The goal commitment had dropped during the organizational change from 3.96 in 2005 to 3.60 in 2007 (scale 1-5) (p = 0.001). Best predictors for the goal commitment of radiography departments' staff were having children (OR 4.4) and perceiving functional environment clearly (OR 2.6). Correlation between the goal commitment and intention to leave of the staff was -0.32 (p = 0.01). Conclusion: From the viewpoint of the commitment of the radiography departments' staff, the trend of uniting quite independent health care units into larger entities seems not to be beneficial. This study reveals that commitment to one's work unit is most of all a question of stability and job security. This is a fact the leadership of the radiography departments should take into account, appreciate and support to assure the tenure and productivity of their workforce.

  5. Videoscopic assessment of the maintenance status of gamma radiography exposure containers employed in Brazil

    International Nuclear Information System (INIS)

    Candeias, J P; Estrada, J J S; Pinho, A S; D'Avila, R L; Ramalho, A T

    2007-01-01

    Industrial radiography is the most frequent method of non-destructive testing (NDT) used by Brazilian industrial facilities for investigating the material integrity of a test object. In Brazil, industrial radiography employs around 220 x-ray and 290 gamma radiography machines. About 90% of the latter uses iridium ( 192 Ir) sources. The large majority of 192 Ir projectors in operation in Brazil have been in continuous usage for more than 25 years, which means that they are old and worn-out. Usually the majority of accidents concerning gamma radiography occur during the return of the source into the exposure container. Poor maintenance or imperfections of the internal channel of the exposure container can lead to accidental source exposure. In the present work the internal tube of 65 gamma machines from nine Brazilian companies that render gamma radiography services were analysed using an industrial videoscope. The internal images from the projectors were compared with the internal image of an apparatus that had never been used, i.e. has never received a radioactive source. From the 65 machines evaluated, nine showed irregularities of the internal tube. It was also observed that each company follows a different methodology for the maintenance and lubrication of the exposure containers and drive cables

  6. Videoscopic assessment of the maintenance status of gamma radiography exposure containers employed in Brazil.

    Science.gov (United States)

    Candeias, J P; Estrada, J J S; Pinho, A S; D'Avila, R L; Ramalho, A T

    2007-03-01

    Industrial radiography is the most frequent method of non-destructive testing (NDT) used by Brazilian industrial facilities for investigating the material integrity of a test object. In Brazil, industrial radiography employs around 220 x-ray and 290 gamma radiography machines. About 90% of the latter uses iridium ((192)Ir) sources. The large majority of (192)Ir projectors in operation in Brazil have been in continuous usage for more than 25 years, which means that they are old and worn-out. Usually the majority of accidents concerning gamma radiography occur during the return of the source into the exposure container. Poor maintenance or imperfections of the internal channel of the exposure container can lead to accidental source exposure. In the present work the internal tube of 65 gamma machines from nine Brazilian companies that render gamma radiography services were analysed using an industrial videoscope. The internal images from the projectors were compared with the internal image of an apparatus that had never been used, i.e. has never received a radioactive source. From the 65 machines evaluated, nine showed irregularities of the internal tube. It was also observed that each company follows a different methodology for the maintenance and lubrication of the exposure containers and drive cables.

  7. Videoscopic assessment of the maintenance status of gamma radiography exposure containers employed in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Candeias, J P [IME, Military Institute of Engineering, Praca Gal Tiburcio 80, Praia Vermelha, Rio de Janeiro, 22290-270 (Brazil); Estrada, J J S [IME, Military Institute of Engineering, Praca Gal Tiburcio 80, Praia Vermelha, Rio de Janeiro, 22290-270 (Brazil); Pinho, A S [Institute of Radioprotection and Dosimetry (IRD/CNEN), Avenida Salvador Allende, PO Box 37750, Rio de Janeiro, 22780-160 (Brazil); D' Avila, R L [Institute of Radioprotection and Dosimetry (IRD/CNEN), Avenida Salvador Allende, PO Box 37750, Rio de Janeiro, 22780-160 (Brazil); Ramalho, A T [Institute of Radioprotection and Dosimetry (IRD/CNEN), Avenida Salvador Allende, PO Box 37750, Rio de Janeiro, 22780-160 (Brazil)

    2007-03-01

    Industrial radiography is the most frequent method of non-destructive testing (NDT) used by Brazilian industrial facilities for investigating the material integrity of a test object. In Brazil, industrial radiography employs around 220 x-ray and 290 gamma radiography machines. About 90% of the latter uses iridium ({sup 192}Ir) sources. The large majority of {sup 192}Ir projectors in operation in Brazil have been in continuous usage for more than 25 years, which means that they are old and worn-out. Usually the majority of accidents concerning gamma radiography occur during the return of the source into the exposure container. Poor maintenance or imperfections of the internal channel of the exposure container can lead to accidental source exposure. In the present work the internal tube of 65 gamma machines from nine Brazilian companies that render gamma radiography services were analysed using an industrial videoscope. The internal images from the projectors were compared with the internal image of an apparatus that had never been used, i.e. has never received a radioactive source. From the 65 machines evaluated, nine showed irregularities of the internal tube. It was also observed that each company follows a different methodology for the maintenance and lubrication of the exposure containers and drive cables.

  8. Chest radiography: new technological developments and their applications

    NARCIS (Netherlands)

    Schalekamp, S.; Ginneken, B. van; Karssemeijer, N.; Schaefer-Prokop, C.M.

    2014-01-01

    Digital chest radiography is still the most common radiological examination. With the upcoming three-dimensional (3D) acquisition techniques the value of radiography seems to diminish. But because radiography is inexpensive, readily available, and requires very little dose, it is still being used

  9. Prior inpatient admission increases the risk of post-operative infection in hepatobiliary and pancreatic surgery.

    Science.gov (United States)

    Dong, Zachary M; Chidi, Alexis P; Goswami, Julie; Han, Katrina; Simmons, Richard L; Rosengart, Matthew R; Tsung, Allan

    2015-12-01

    Hepatobiliary and pancreatic (HPB) operations have a high incidence of post-operative nosocomial infections. The aim of the present study was to determine whether hospitalization up to 1 year before HPB surgery is associated with an increased risk of post-operative infection, surgical-site infection (SSI) and infection resistant to surgical chemoprophylaxis. A retrospective cohort study of patients undergoing HPB surgeries between January 2008 and June 2013 was conducted. A multivariable logistic regression model was used for controlling for potential confounders to determine the association between pre-operative admission and post-operative infection. Of the 1384 patients who met eligibility criteria, 127 (9.18%) experienced a post-operative infection. Pre-operative hospitalization was independently associated with an increased risk of a post-operative infection [adjusted odds ratio (aOR): 1.61, 95% confidence interval [CI]: 1.06-2.46] and SSI (aOR: 1.79, 95% CI: 1.07-2.97). Pre-operative hospitalization was also associated with an increased risk of post-operative infections resistant to standard pre-operative antibiotics (OR: 2.64, 95% CI: 1.06-6.59) and an increased risk of resistant SSIs (OR: 3.99, 95% CI: 1.25-12.73). Pre-operative hospitalization is associated with an increased incidence of post-operative infections, often with organisms that are resistant to surgical chemoprophylaxis. Patients hospitalized up to 1 year before HPB surgery may benefit from extended spectrum chemoprophylaxis. © 2015 International Hepato-Pancreato-Biliary Association.

  10. CT imaging vs. traditional radiographic imaging for evaluating Harris Lines in tibiae

    DEFF Research Database (Denmark)

    Primeau, Charlotte; Jakobsen, Lykke Schrøder; Lynnerup, Niels

    2016-01-01

    This paper is the first to systematically investigate computer tomography (CT) images vs. ordinary flat plane radiography for evaluating Harris Lines (HL) on tibiae. Harris Lines are traditionally investigated using radiographic images and recorded as either present or absent, or by counting...

  11. Similar failure rate in immediate post-operative weight bearing versus protected weight bearing following meniscal repair on peripheral, vertical meniscal tears.

    Science.gov (United States)

    Perkins, Bryan; Gronbeck, Kyle R; Yue, Ruixian Alexander; Tompkins, Marc A

    2017-08-16

    Post-operative weight bearing after meniscal repair is a point of debate among physicians. This study sought to evaluate whether patients adhering to an immediate WBAT rehabilitation programme have a higher failure rate compared to those adhering to a more traditional, protected, NWB status following meniscal repair. The null hypothesis was that there would be no difference in failure between the two groups. A retrospective review of meniscal repair patients greater than 5 years from surgery was performed for patients receiving meniscal repair treatment. Patients were categorized by post-surgical weight-bearing status, either NWB or WBAT, and then analysed for failure of repair. Failure was defined as re-operation on the torn meniscus. The study controlled for variables including age at surgery, sex, height, weight, and BMI, classification of tear type, acuity of the tear, repair location (medial or lateral), repair location within the meniscus, repair technique, and concomitant procedures. Re-operations were performed in 61 of 157 patients [38.9%]. There was no difference between weight-bearing groups for failure of meniscus repair (n.s.). The tears were acute vertical tears located in the posterior horn and body. For the 61 patients with re-operation, the average time to re-operation was 2.2 years with 10 [16%] > 5 years from surgery, 17 [28%] 2-5 years from surgery, and 34 [56%] bearing groups for rate of re-operation (n.s.). Weight bearing as tolerated after meniscal repair for peripheral, vertical tears does not result in a higher failure rate than traditional, non-weight bearing over a five-year follow-up period. The clinical relevance is that, based on these data, it may be appropriate to allow weight bearing as tolerated following meniscal repair of peripheral, vertical tears. Retrospective cohort study, Level III.

  12. Digital and analogue industrial radiography, application fields

    International Nuclear Information System (INIS)

    Willems, Peter; Millord, Erik Yardin

    2000-01-01

    Full text: Reusable phosphor screens for computer radiography (CR), amorphous selenium screens for direct radiography (DR), film digitalisation (FD) constitute imaging methods accepted by industry and are used for non-destructive radiographic testing (RT). Economic pressures are involving and affecting digital RT technology. Standards and codes for film radiography and radioscopy qualification do no longer cover the wide range of digital RT applications. It will be our task to optimise the performance of digital RT characterisation and to create appropriate examination methods to use all these new and existent technologies. In the meantime, an increasing automation and control of manual methods of analogue radiography can as well be expected. (author)

  13. Proceeding of 6th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Katsurayama, Kohsuke; Hiraoka, Eiichi; Tsujimoto, Tadashi

    1984-01-01

    The 6th short conference on neutron radiography was held on August 30 and 31, 1983, at the Research Reactor Institute, Kyoto niversity, as a part of the joint research program of the Institute. During the period since the first meeting in November, 1970, steady development was made in both research and practical use of neutron radiography in Japan owing to the persistent effort of the persons concerned. In the conference, 70 persons participated, and 21 papers were presented. The problems treated were the apparatuses of neutron television, neutron radiography and neutron photography, the various application of neutron radiography, the standard of neutron radiography and others. The high value of neutron radiography and the increasing demand to use this technique were shown in this meeting. Considering the recent rapid development of new technology, it is expected that neutron radiography will find the wide varieties of application in the near future. The proceedings of the conference are published by collecting the gists of papers, hoping to enhance joint effort and the exchange of information to develop neutron radiography. (Kako, I.)

  14. Neutron radiography of fuel pins

    International Nuclear Information System (INIS)

    Jackson, C.N. Jr.; Powers, H.G.; Burgess, C.A.

    1975-01-01

    Neutron radiography performed with a reactor source has been shown to be a superior radiographic method for the examination of unirradiated mixed oxide fuel pins at the Hanford Engineering Development Laboratory. Approximately 1,700 fuel pins were contained in a sample that demonstrated the capability of the method for detecting laminations, structural flaws, fissile density variation, hydrogenous inclusions and voids in assembled fuel pins. The nature, extent, and importance of the detected conditions are substantiated by gamma autoradiography and by destructive analysis employing alpha autoradiography, electron microprobe and visual inspection. Also, a series of radiographs illustrate the response of neutron radiography as compared to low voltage and high voltage x-ray and gamma source Iridium 192 radiography. (U.S.)

  15. Mass chest radiography in Greece

    International Nuclear Information System (INIS)

    Papavasiliou, C.

    1987-01-01

    In Greece mass chest radiography has been performed regularly on various population groups as a measure to control tuberculosis. Routine chest radiography is performed in most Greek hospitals on admission. In this report available data-admittedly inadequate-directly or indirectly addressing the problem of benefit versus the risk or cost associated with this examination is presented

  16. Practical radiography. 11. ed.

    International Nuclear Information System (INIS)

    Hoxter, E.A.

    1982-01-01

    After a brief explanation of the basics of electricity, the fundamentals of radiography are dealt with in more detail - the discovery of X-rays, their nature and properties, the production of the X-ray image and ways of improving the image. A chapter is devoted to the important subject of radiation protection. Explanations are given of the use of the Siemens exposure tables, which make it simpler to modify exposures from the values given in the tables. There is also a section on some of the standard radiographic positioning for patients. The most common medical terms used in radiography and fluoroscopy are listed and an Appendix gives details of the major items of Siemens X-ray equipment. There is a list of literature recommended for further study. Theoretical explanations have been kept to a minimum so that information that is important to radiography can be emphasized. (orig./MG)

  17. Standardization activities of the Euratom Neutron Radiography Working Group

    International Nuclear Information System (INIS)

    Domanus, J.

    1982-06-01

    In 1979 a working group on neutron radiography was formed at Euratom. The purpose of this group is the standardization of neutron radiographic methods in the field of nuclear fuel. Activities of this Neutron Radiography Working Group are revised. Classification of defects revealed by neutron radiography is illustrated in a special atlas. Beam purity and sensitivity indicators are tested together with a special calibration fuel pin. All the Euratom neutron radiography centers will perform comparative neutron radiography with those items. The measuring results obtained, using various measuring aparatus will form the basis to formulate conclusions about the best measuring methods and instruments to be used in that field. Besides the atlas of neutron radiographic findings in light water reactor fuel, the Euratom Neutron Radiogrphy Working Group has published a neutron radiography handbook in which the neutron radiography installations in the European Community are also described. (author)

  18. Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography

    International Nuclear Information System (INIS)

    Gondo, Gakuji; Ishiwata, Yusuke; Yamashita, Toshinori; Iida, Takashi; Moro, Yutaka

    1989-01-01

    Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography (CR) are discussed. Computed radiography is a digital radiography system in which an imaging plate is used as an X-ray detector and a final image is displayed on the film. In the angiograms performed with CR, the spatial frequency components can be enhanced for the easy analysis of fine blood vessels. Computed radiography has an automatic sensitivity and a latitude-setting mechanism, thus serving as an 'automatic camera.' This mechanism is useful for radiography with a mobile X-ray unit in hospital wards, intensive care units, or operating rooms where the appropriate setting of exposure conditions is difficult. We applied this mechanism to direct percutaneous carotid angiography and intravenous digital subtraction angiography with a mobile X-ray unit. Direct percutaneous carotid angiography using CR and a mobile X-ray unit were taken after the manual injection of a small amount of a contrast material through a fine needle. We performed direct percutaneous carotid angiography with this method 68 times on 25 cases from August 1986 to December 1987. Of the 68 angiograms, 61 were evaluated as good, compared with conventional angiography. Though the remaining seven were evaluated as poor, they were still diagnostically effective. This method is found useful for carotid angiography in emergency rooms, intensive care units, or operating rooms. Cerebral venography using CR and a mobile X-ray unit was done after the manual injection of a contrast material through the bilateral cubital veins. The cerebral venous system could be visualized from 16 to 24 seconds after the beginning of the injection of the contrast material. We performed cerebral venography with this method 14 times on six cases. These venograms were better than conventional angiograms in all cases. This method may be useful in managing patients suffering from cerebral venous thrombosis. (J.P.N.)

  19. Sternal wound complications after primary isolated myocardial revascularization: the importance of the post-operative variables.

    NARCIS (Netherlands)

    Noyez, L.; Druten, J.A.M. van; Mulder, J.; Schroen, A.M.; Skotnicki, S.H.; Brouwer, R.

    2001-01-01

    OBJECTIVE: Select pre-, peri-, and post-operative variables, predictive for sternal wound complications (SWC), in a clinical setting. METHODS: We analyzed pre-, peri-, and post-operative data of 3815 patients who underwent a primary isolated bypass grafting. 100 patients (2.6%) had post-operative

  20. A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference

    International Nuclear Information System (INIS)

    Choo, Ji Yung; Lee, Ki Yeol; Choi, Jung Won; Yu, Ami; Kim, Je-Hyeong; Lee, Seung Heon; Kang, Eun-Young; Oh, Yu Whan

    2016-01-01

    To compare the diagnostic performance of digital tomosynthesis (DTS) and chest radiography for detecting airway abnormalities, using computed tomography (CT) as a reference. We evaluated 161 data sets from 149 patients (91 with and 70 without airway abnormalities) who had undergone radiography, DTS, and CT to detect airway problems. Radiographs and DTS were evaluated to localize and score the severity of the airway abnormalities, and to score the image quality using CT as a reference. Receiver operating characteristics (ROC), McNemar's test, weighted kappa, and the paired t-test were used for statistical analysis. The sensitivity of DTS was higher (reader 1, 93.51 %; reader 2, 94.29 %) than chest radiography (68.83 %; 71.43 %) in detecting airway lesions. The diagnostic accuracy of DTS (90.91 %; 94.70 %) was also significantly better than that of radiography (78.03 %; 82.58 %, all p < 0.05). DTS image quality was significantly better than chest radiography (1.83, 2.74; p < 0.05) in the results of both readers. The inter-observer agreement with respect to DTS findings was moderate and superior when compared to radiography findings. DTS is a more accurate and sensitive modality than radiography for detecting airway lesions that are easily obscured by soft tissue structures in the mediastinum. (orig.)

  1. The real-time neutron radiography system at Texas A and M University

    International Nuclear Information System (INIS)

    Reuscher, Jon A.

    1990-01-01

    This paper reports on the development and fabrication of a real-time system at Texas A and M University using commercially available and relatively inexpensive components. The real-time neutron radiography system consists of two major components: a camera and image processing equipment. The neutron beam provides a thermal neutron flux of 10 neutrons/cm -sec (cadmium ratio of 4.0) with the TRIGA reactor operating at a power of 1 MW. A remotely operated turntable is used to position the sample in the neutron beam for optimum viewing and ease of changing position. The front surface mirror at 45 deg. to the neutron beam reflects the scintillation image to the lens. The IRO and CCD camera are placed behind shielding out of the neutron. Results using the imaging system for a cadmium plate (0.032 inch thick) with several holes of different diameters are presented. Applications of this neutron radiography system include sensitivity indicators for the spatial resolution of bubbles in water-filled tubes, moisture content of zeolite samples, operating heat pipes and the freezing and thawing of metallic samples

  2. A picture of radiography education across Europe

    International Nuclear Information System (INIS)

    McNulty, J.P.; Rainford, L.; Bezzina, P.; Henner, A.; Kukkes, T.; Pronk-Larive, D.; Vandulek, C.

    2016-01-01

    Purpose: To establish an understanding of radiography education across Europe by surveying higher education institutions registered as affiliate members of the European Federation of Radiography Societies (EFRS). Method: An online survey was developed to ascertain data on: curricula, duration, credit load, accreditation requirements, staff qualifications, staff and student exchange opportunities, and availability of postgraduate programmes. Responses were identifiable in terms of educational institution and country. All 46 affiliated educational institutions were invited to participate in the survey. Descriptive and thematic analyses are reported. Results: A response rate of 89.1% (n = 41) was achieved from educational institutions representing 21 countries. The majority of institutions (63.4%) offer a combined Medical Imaging, Radiotherapy and Nuclear Medicine programme; dedicated Medical Imaging programmes are offered by 14 institutions (34.2%); dedicated Radiotherapy programme by one institution (2.4%), and a dedicated Nuclear Medicine programme by only three institutions (6.5%). The Bologna (Bachelor) cycle has been adopted by 90.2% of responding institutions. The majority of institutions (53.7%) indicated programmes of 3 years in duration, others stated 3.5–4 years. Only 14.6% of institutions require ‘International Level’ accreditation for the Bachelors radiography programme. Postgraduate programmes were not offered by 26.8% of institutions and a deficit in Doctoral status for radiography educators was identified. Conclusions: The Bologna (Bachelor) cycle for radiography education has been adopted across the majority of institutions, however, full alignment remains a priority. Postgraduate radiography education opportunities across Europe appear to be insufficient and further investigation of radiography accreditation processes is justified to ensure harmonisation of practice. - Highlights: • The majority of institutions are compliant with the

  3. Landscape design strategies for post-disaster reconstructions based on traditional ethical wisdom

    Science.gov (United States)

    Yi, Shouli; Hu, Di; Gao, Suping; Lei, Ting; Chen, Qibin

    2018-03-01

    In the face of the black swan events which frequently happened globally, I take the earthquake of Ya'an, happened at 4.20 in Sichuan, as an example of my subject. The results indicate that the social responsibility of landscape architects is a post-disaster reconstruction of a material and spiritual homeland for victims and mental care for individuals, which specifically reflected in the process of rebuilding victims' sense of security. The reconstruction of a sense of security must follow certain ethics and moralities which embody the ecological wisdom. We take a typical case of Ya'an Lushan Snow Mountain Village-the earthquake distress area, we found the incidence of disease was up to 68.6% through the PTSD analysis, indicating the overall absence of a sense of security. To solve the problem and reconstruct people's mental and material homeland, the article discussed the strategies and solutions to post-disaster landscape design based on traditional ethical wisdom.

  4. Quality assurance in film radiography

    International Nuclear Information System (INIS)

    Barber, G.W.

    1996-01-01

    Non-destructive testing in the form of radiography is an inherent part of the manufacturing process. In the development stage - it helps locating physical discontinuities of the component and provides a feedback to specify suitable process, and balanced acceptance criteria, keeping in view the cost of manufacture and demands of specification and performance. In the manufacturing stage - it locates the discontinuities occurring at various stages of manufacture, ensuring timely intervention to prevent the production of scrap and/or rework and loss of energy. In the operation stage, it helps in-service and on-line monitoring of components and plants to avert and ensure planned minimum shutdowns

  5. Pre-operative and early post-operative factors associated with surgical site infection after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Oller, Inmaculada; Llavero, Carolina; Arroyo, Antonio; Muñoz, Jose Luis; Calero, Alicia; Diez, María; Zubiaga, Lorea; Calpena, Rafael

    2013-08-01

    Surgical procedures on obese patients are expected to have a high incidence of surgical site infection (SSI). The identification of pre-operative or early post-operative risk factors for SSI may help the surgeon to identify subjects in risk and adequately optimize their status. We conducted a study of the association of comorbidities and pre- and post-operative analytical variables with SSI following laparoscopic sleeve gastrectomy for the treatment of morbid obesity. We performed a prospective study of all morbidly obese patients undergoing laparoscopic sleeve gastrectomy as a bariatric procedure between 2007 and 2011. An association of clinical and analytical variables with SSI was investigated. The study included 40 patients with a mean pre-operative body mass index (BMI) of 51.2±7.9 kg/m(2). Surgical site infections appeared in three patients (7.5%), of whom two had an intra-abdominal abscess located in the left hypochondrium and the third had a superficial incisional SSI. Pre-operatively, a BMI >45 kg/m(2) (OR 8.7; p=0.008), restrictive disorders identified by pulmonary function tests (OR 10.0; p=0.012), a serum total protein concentration 30 mcg/dL (OR 13.0; p=0.003), and a mean corpuscular volume (MCV) operative SSI. Post-operatively, a serum glucose >128 mg/dL (OR 4.7; p=0.012) and hemoglobin operative anemia and hyperglycemia as risk factors for SSI. In these situations, the surgeon must be aware of and seek to control these risk factors.

  6. Information extraction from muon radiography data

    International Nuclear Information System (INIS)

    Borozdin, K.N.; Asaki, T.J.; Chartrand, R.; Hengartner, N.W.; Hogan, G.E.; Morris, C.L.; Priedhorsky, W.C.; Schirato, R.C.; Schultz, L.J.; Sottile, M.J.; Vixie, K.R.; Wohlberg, B.E.; Blanpied, G.

    2004-01-01

    Scattering muon radiography was proposed recently as a technique of detection and 3-d imaging for dense high-Z objects. High-energy cosmic ray muons are deflected in matter in the process of multiple Coulomb scattering. By measuring the deflection angles we are able to reconstruct the configuration of high-Z material in the object. We discuss the methods for information extraction from muon radiography data. Tomographic methods widely used in medical images have been applied to a specific muon radiography information source. Alternative simple technique based on the counting of high-scattered muons in the voxels seems to be efficient in many simulated scenes. SVM-based classifiers and clustering algorithms may allow detection of compact high-Z object without full image reconstruction. The efficiency of muon radiography can be increased using additional informational sources, such as momentum estimation, stopping power measurement, and detection of muonic atom emission.

  7. Prophylactic post-operative radiotherapy prevents heterotopic ossification following traumatic acetabular fracture

    International Nuclear Information System (INIS)

    Meyer, Joseph T.; Hixson, William C.; Jennelle, Richard L. S.; Alonso, Jorge E.; Raben, David; Spencer, Sharon S.; Kim, Robert Y.

    1996-01-01

    Purpose/Objective: To determine the effect of post-operative radiation on the incidence of heterotopic ossification following traumatic acetabular fracture. Materials and Methods: A retrospective analysis was performed of the medical records and radiographs of all patients who received prophylactic radiotherapy to prevent heterotopic ossification. These results were compared to a similar group of patients receiving no prophylactic radiotherapy following traumatic acetabular fracture. Between 1987 and 1994, sixty-six patients received prophylactic radiotherapy to prevent heterotopic ossification. Results: Thirty-six patients (55%) received radiotherapy following operative repair of a traumatic acetabular fracture (median follow-up: 210 days). Three dose schedules were utilized: (28(36)) (77.8%) received 700 cGy/1 fx, (2(36)) (5.5%) 800 cGy/1 fx, and (6(36)) (16.7%) 1000 cGy/5 fxs. These patients were retrospectively compared with thirty-four patients who received similar operative management of traumatic acetabular fractures without post-operative radiotherapy (median follow-up: 378 days). Of the patients with heterotopic ossification, 96% developed it within 180 days. Complications and delayed wound healing rates were not significantly different in patients treated with or without post-operative radiotherapy, 6.4% and 6.3% respectively (p=0.49). The incidence of heterotopic ossification at last follow-up in patients treated with and without post-operative radiotherapy was (5(36)) (13.9%) and (19(34)) (55.9%), respectively (p=0.000332). For all patients, type of surgical approach was associated with development of heterotopic ossification: posterior, (7(38)) (18.4%), ilio-inguinal (1(3)) (33.3%), tri-radiate (13(19)) (68.4%), p=.000511. In patients receiving post-operative radiotherapy, variables associated with heterotopic ossification included dose (p=.00962), injury-to-radiation interval (p=.0038), and surgery-to-radiation interval (p=.0238). Fifty percent ((3

  8. Quality assurance of computed and digital radiography systems

    International Nuclear Information System (INIS)

    Walsh, C.; Gorman, D.; Byrne, P.; Larkin, A.; Dowling, A.; Malone, J. F.

    2008-01-01

    Computed radiography (CR) and digital radiography (DR) are replacing traditional film screen radiography as hospitals move towards digital imaging and picture archiving and communication systems (PACS). Both IPEM and KCARE have recently published quality assurance and acceptance testing guidelines for DR. In this paper, the performance of a range of CR and DR systems is compared. Six different manufacturers are included. Particular attention is paid to the performance of the systems under automatic exposure control (AEC). The patient is simulated using a range of thicknesses of tissue equivalent material. Image quality assessment was based on detector assessment protocols and includes pixel value measures as well as subjective assessment using Leeds Test Objects. The protocols for detector assessment cover a broad range of tests and in general detectors (whether DR or CR) performed satisfactorily. The chief limitation in performing these tests was that not all systems provided ready access to pixel values. Subjective tests include the use of the Leeds TO20. As part of this work, suggested reference values are provided to calculate the TO20 image quality factor. One consequence of moving from film screen to digital technologies is that the dynamic range of digital detectors is much wider, and increased exposures are no longer evident from changes in image quality. As such, AEC is a key parameter for CR and DR. Dose was measured using a standard phantom as a basic means of comparing systems. In order to assess the AEC performance, exit doses were also measured while varying phantom thickness. Signal-to-noise ratios (SNRs) were calculated on a number of systems where pixel values were available. SNR was affected by the selection of acquisition protocol. Comparisons between different technologies and collation of data will help refine acceptance thresholds and contribute to optimising dose and image quality. (authors)

  9. Filmless radiography - present possibilities and direction of future developing

    International Nuclear Information System (INIS)

    Wocial, A.; Wojciechowski, Z.A.; Rozenblicki, Z.

    2008-01-01

    The paper presents introduction for new filmless radiography like CR Computed Radiography and DR Digital Radiography direct and non direct. The main factors are considered, which determine classification to different type of radiography. For each technique authors describe advantages and disadvantages supporting by practice examples. Paper contains a lot of practical information about a most of existing radiographic equipment at the NDT market. (author)

  10. SIMPLE for industrial radiography

    International Nuclear Information System (INIS)

    Azhar Azmi; Abd Nassir Ibrahim; Siti Madiha Muhammad Amir; Glam Hadzir Patai Mohamad; Saidi Rajab

    2004-01-01

    The first thing industrial radiographers have to do before commencing radiography works is to determine manually the amount of correct exposure that the film need to be exposed in order to obtain the right density. The amount of exposure depends on many variables such as type of radioisotope, type of film, nature of test-object and its orientation, and specific arrangement related to object location and configuration. In many cases radiography works are rejected because of radiographs fail to meet certain reference criteria as defined in the applicable standard. One of the main reasons of radiograph rejection is due to inadequate exposure received by the films. SIMPLE is a software specially developed to facilitate the calculation of gamma-radiography exposure. By using this software and knowing radiographic parameters to be encountered during the work, it is expected that human error will be minimized, thus enhancing the quality and productivity of NDT jobs. (Author)

  11. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  12. Heavy-ion radiography applied to charged particle radiotherapy

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Fabrikant, J.I.; Holley, W.R.; Tobias, C.A.; Castro, J.R.

    1980-01-01

    The objectives of the heavy-ion radiography research program applied to the clinical cancer research program of charged particle radiotherapy have a twofold purpose: (1) to explore the manner in which heavy-ion radiography and CT reconstruction can provide improved tumor localization, treatment planning, and beam delivery for radiotherapy with accelerated heavy charged particles; and (2) to explore the usefulness of heavy-ion radiography in detecting, localizing, and sizing soft tissue cancers in the human body. The techniques and procedures developed for heavy-ion radiography should prove successful in support of charged particle radiotherapy

  13. Intravenous analgesics for pain management in post- operative ...

    African Journals Online (AJOL)

    Intravenous analgesics for pain management in post- operative patients: a comparative study of their efficacy and adverse ... patient anxiety, stress, and dissatisfaction. Adequate ... genders who were scheduled to undergo abdominal surgery (hemicolectomy, exploratory ... analysis (n = 48) and separated into three groups.

  14. Absorbed doses for patients undergoing panoramic radiography, cephalometric radiography and CBCT

    Directory of Open Access Journals (Sweden)

    Małgorzata Wrzesień

    2017-10-01

    Full Text Available Objectives: Contemporary dental radiology offers a wide spectrum of imaging methods but it also contributes to an increase in the participation of dental radiological diagnosis in the patient’s exposure to ionizing radiation. The aim of this study is to determine the absorbed doses of the brain, spinal column, thyroid and eye lens for patients during panoramic radiography, cephalometric radiography and cone beam computed tomography (CBCT. Material and Methods: The thermoluminescent dosimetry and anthropomorphic phantom was used for measuring the doses. The 15 panoramic, 4 cephalometric and 4 CBCT exposures were performed by placing high-sensitivity thermoluminescent detectors (TLD in 18 anatomical points of the phantom. Results: The maximum absorbed dose recorded during performed measurements corresponds to the point representing the brainstem and it is 10 mGy. The dose value recorded by the TLD placed in the thyroid during CBCT imaging in relation to the panoramic radiography differs by a factor of 13.5. Conclusions: Cone beam computed tomography, in comparison with panoramic or cephalometric imaging technique, provides higher radiation doses to the patients. Int J Occup Med Environ Health 2017;30(5:705–713

  15. A comparison of digital tomosynthesis and chest radiography in evaluating airway lesions using computed tomography as a reference.

    Science.gov (United States)

    Choo, Ji Yung; Lee, Ki Yeol; Yu, Ami; Kim, Je-Hyeong; Lee, Seung Heon; Choi, Jung Won; Kang, Eun-Young; Oh, Yu Whan

    2016-09-01

    To compare the diagnostic performance of digital tomosynthesis (DTS) and chest radiography for detecting airway abnormalities, using computed tomography (CT) as a reference. We evaluated 161 data sets from 149 patients (91 with and 70 without airway abnormalities) who had undergone radiography, DTS, and CT to detect airway problems. Radiographs and DTS were evaluated to localize and score the severity of the airway abnormalities, and to score the image quality using CT as a reference. Receiver operating characteristics (ROC), McNemar's test, weighted kappa, and the paired t-test were used for statistical analysis. The sensitivity of DTS was higher (reader 1, 93.51 %; reader 2, 94.29 %) than chest radiography (68.83 %; 71.43 %) in detecting airway lesions. The diagnostic accuracy of DTS (90.91 %; 94.70 %) was also significantly better than that of radiography (78.03 %; 82.58 %, all p chest radiography (1.83, 2.74; p < 0.05) in the results of both readers. The inter-observer agreement with respect to DTS findings was moderate and superior when compared to radiography findings. DTS is a more accurate and sensitive modality than radiography for detecting airway lesions that are easily obscured by soft tissue structures in the mediastinum. • Digital tomosynthesis offers new diagnostic options for airway lesions. • Digital tomosynthesis is more sensitive and accurate than radiography for airway lesions. • Digital tomosynthesis shows better image quality than radiography. • Assessment of lesion severity, via tomosynthesis is comparable to computed tomography.

  16. Low degree of satisfactory individual pain relief in post-operative pain trials.

    Science.gov (United States)

    Geisler, A; Dahl, J B; Karlsen, A P H; Persson, E; Mathiesen, O

    2017-01-01

    The majority of clinical trials regarding post-operative pain treatment focuses on the average analgesic efficacy, rather than on efficacy in individual patients. It has been argued, that in acute pain trials, the underlying distributions are often skewed, which makes the average unfit as the only way to measure efficacy. Consequently, dichotomised, individual responder analyses using a predefined 'favourable' response, e.g. Visual Analogue Scale (VAS) pain scores ≤ 30, have recently been suggested as a more clinical relevant outcome. We re-analysed data from 16 randomised controlled trials of post-operative pain treatment and from meta-analyses of a systematic review regarding hip arthroplasty. The predefined success criterion was that at least 80% of patients in active treatment groups should obtain VAS < 30 at 6 and 24 h post-operatively. In the analysis of data from the randomised controlled trials, we found that at 6 h post-operatively, 50% (95% CI: 31-69) of patients allocated to active treatment reached the success criterion for pain at rest and 14% (95% CI: 5-34) for pain during mobilisation. At 24 h post-operatively, 60% (95% CI: 38-78) of patients allocated to active treatment reached the success criterion for pain at rest, and 15% (95% CI: 5-36) for pain during mobilisation. Similar results were found for trials from the meta-analyses. Our results indicate that for conventional, explanatory trials of post-operative pain, individual patient's achievement of a favourable response to analgesic treatment is rather low. Future pragmatic clinical trials should focus on both average pain levels and individual responder analyses in order to promote effective pain treatment at the individually patient level. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  18. Industrial Radiography: Principle and Practical

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    The successful and effectiveness of radiography method as a tool to increase quality level and safety of the engineering system and processing plants depend with the level of radiographer knowledge as service provider and also as supervisor. This book was published as effort several local experts to give their knowledge, theory and practical related to radiography technique to the involved public directly or indirectly. This book started with basic physic knowledge that becomes a root to radiography technology. Then, followed by discussion on tools and device that used in radiography work including x-ray machine, gamma projector, film, dark room, and others. Each aspect of radiograph quality also mentioned here to guide the reader on how to produce good radiograph that filled the specification wanted. The good radiograph does not mean anything if it failed to be interpreted correctly. Because of that, this book also explain how to choose good radiograph that qualified to be interpreted and after that how interpretation and evaluation process of object quality inspected was implemented based on image digestion that showed in radiograph. Several code and standard that usually applied in this country also will be referred as well for this work.

  19. Post-Operative Infection Is an Independent Risk Factor for Worse Long-Term Survival after Colorectal Cancer Surgery.

    Science.gov (United States)

    Kerin Povšič, Milena; Ihan, Alojz; Beovič, Bojana

    2016-12-01

    Colorectal cancer surgery is associated with a high incidence of post-operative infections, the outcome of which may be improved if diagnosed and treated early enough. We compared white blood cell (WBC) count, C-reactive protein (CRP), and procalcitonin (PCT) as predictors of post-operative infections and analyzed their impact on long-term survival. This retrospective study included 186 patients undergoing colorectal surgery. Post-operative values of WBC, CRP, and PCT were analyzed by the receiver operating characteristic (ROC) analysis. We followed infections 30 d after the surgery. A five-year survival was analyzed by Kaplan-Meier method and prognostic factors by Cox regression model. Fifty-five patients (29.5%) developed post-operative infection, the most frequent of which was surgical site infection (SSI). C-reactive protein on post-operative day three and PCT on post-operative day two demonstrated the highest diagnostic accuracy for infection (area under the curve [AUC] 0.739 and 0.735). C-reactive protein on post-operative day three was an independent predictor of infection. Five-year survival was higher in the non-infected group (70.8%), compared with the infected group (52.1%). The worst survival (40.9%) was identified in patients with organ/space SSI. Post-operative infection and tumor stage III-IV were independent predictors of a worse five-year survival. C-reactive protein on post-operative day three and PCT on post-operative day two may be early predictors of infection after colorectal cancer surgery. Post-operative infections in particular organ/space SSI have a negative impact on long-term survival.

  20. Factors associated with the goal commitment of radiography departments' staff in organizational change

    Energy Technology Data Exchange (ETDEWEB)

    Groenroos, Eija [Helsinki Metropolia University of Applied Sciences, Degree Programme in Radiography and Radiotherapy, Mannerheimintie 172, 00300 Helsinki (Finland)], E-mail: eija.gronroos@metropolia.fi; Pajukari, Arja [MHS, Hus-Roentgen, PL 809, 00029 Hus (Finland)], E-mail: arja.pajukari@hus.fi; Matinheikki-Kokko, Kaija [Helsinki Metropolia University of Applied Sciences, Mannerheimintie 172, 00300 Helsinki (Finland)

    2009-11-15

    Purpose: The aim of the study is to examine factors associated with the goal commitment of radiography departments' staff. The associations studied are (1) organizational change, (2) work-related factors, (3) psychosocial work environment, and (4) intention to leave. Method: The follow-up study was performed between 2005 and 2007 in co-operation with 10 radiography departments of two Finnish municipalities. In 2005 the response rate was 60% (n = 97/163) and in 2007 it was 49% (n = 73/150). Results: The goal commitment had dropped during the organizational change from 3.96 in 2005 to 3.60 in 2007 (scale 1-5) (p = 0.001). Best predictors for the goal commitment of radiography departments' staff were having children (OR 4.4) and perceiving functional environment clearly (OR 2.6). Correlation between the goal commitment and intention to leave of the staff was -0.32 (p = 0.01). Conclusion: From the viewpoint of the commitment of the radiography departments' staff, the trend of uniting quite independent health care units into larger entities seems not to be beneficial. This study reveals that commitment to one's work unit is most of all a question of stability and job security. This is a fact the leadership of the radiography departments should take into account, appreciate and support to assure the tenure and productivity of their workforce.

  1. Radiation Safety in Industrial Radiography. Specific Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  2. Radiation Safety in Industrial Radiography. Specific Safety Guide (French Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in … shielded facilities that have effective engineering controls and in outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography

  3. Radiation Safety in Industrial Radiography. Specific Safety Guide (Arabic Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    This Safety Guide provides recommendations for ensuring radiation safety in industrial radiography used in non-destructive testing. This includes industrial radiography work that utilizes X ray and gamma sources, both in shielded facilities that have effective engineering controls and outside shielded facilities using mobile sources. Contents: 1. Introduction; 2. Duties and responsibilities; 3. Safety assessment; 4. Radiation protection programme; 5. Training and qualification; 6. Individual monitoring of workers; 7. Workplace monitoring; 8. Control of radioactive sources; 9. Safety of industrial radiography sources and exposure devices; 10. Radiography in shielded enclosures; 11. Site radiography; 12. Transport of radioactive sources; 13. Emergency preparedness and response; Appendix: IAEA categorization of radioactive sources; Annex I: Example safety assessment; Annex II: Overview of industrial radiography sources and equipment; Annex III: Examples of accidents in industrial radiography.

  4. Neutron radiography at the SCK/CEN

    International Nuclear Information System (INIS)

    Tourwe, H.

    1977-01-01

    Neutron radiography has become in recent years a very important method of nondestructive testing in industry and research. The earliest practical application of neutron radiography has probably been the inspection of highly radioactive material: originally irradiated reactor fuels. Applications then progressed to other nuclear and industrial inspection problems. Neutron radiography and the conventional X-ray or gamma techniques are complementary. Some of the most important application fields of neutron radiography are: the detection of light elements (H, Li, B,...) with a very high scattering of absorption cross section for thermal neutrons; the nondestructive control of fuel before and after irradiation; controls where a distinction has to be made between isotopes of the same element ( 235 U and 238 U, 10 B and 11 B,...) and between components of a similar atomic number (Fe and Zn); the control of materials with a high density; the study of corrosion in closed structures; the control of the homogeneity of foreign materials in alloys,.... (author)

  5. Applications of some non destructive testing techniques to the characterization of calcareous rocks: ultrasounds, X and gamma-ray radiography, tomography, neutron radiography

    International Nuclear Information System (INIS)

    Sicardy, O.

    1986-02-01

    NUCLEART Laboratory has been developping various techniques of conservation of art objects made of wood or stone. It has, among others, achieved a technique of strengthening porous stone objects, by resin impregnation followed by polymerization under gamma rays. The good conduct of such operations implies the existence of characterization means, before and after treatment of the objects. Two means of rocks characterization have been studied: - ultrasound techniques, - radiography techniques. The first part consists in a general description of the calcareous rocks morphology and a presentation of the studied specimens. The second part deals with the application of ultrasound techniques to rocks. Experimentally, one pays particular attention to the specific aspects of ultrasounds propagation inside materials like porous rocks, and especially diffusion phenomena. Results were interpreted in terms of propagation medium structure. Practical interest for rocks control through such techniques has been underligned. The third part concerns the application of radiographic techniques to calcareous rocks. Experimental work consists in establishing exposure curves for a wide range of energy, and the images quality determination. Through a statistics approach, and using digitalization techniques, one has done an exhaustive study of the radiographic noise. Moreover two techniques close to conventional radiography were explored: neutron radiography and X-ray tomography. Their specificity and interest in the case of calcareous rocks have been shown [fr

  6. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography

    International Nuclear Information System (INIS)

    Gruber, Michael; Uffmann, Martin; Weber, Michael; Balassy, Csilla; Schaefer-Prokop, Cornelia; Prokop, Mathias

    2006-01-01

    The image quality of dual-reading computed radiography and dose-reduced direct radiography of the chest was compared in a clinical setting. The study group consisted of 50 patients that underwent three posteroanterior chest radiographs within minutes, one image obtained with a dual read-out computed radiography system (CR; Fuji 5501) at regular dose and two images with a flat panel direct detector unit (DR; Diagnost, Philips). The DR images were obtained with the same and with 50% of the dose used for the CR images. Images were evaluated in a blinded side-by-side comparison. Eight radiologists ranked the visually perceivable difference in image quality using a three-point scale. Then, three radiologists scored the visibility of anatomic landmarks in low and high attenuation areas and image noise. Statistical analysis was based on Friedman tests and Wilcoxon rank sum tests at a significance level of P<0.05. DR was judged superior to CR for the delineation of structures in high attenuation areas of the mediastinum even when obtained with 50% less dose (P<0.001). The visibility of most pulmonary structures was judged equivalent with both techniques, regardless of acquisition dose and speed level. Scores for image noise were lower for DR compared with CR, with the exception of DR obtained at a reduced dose. Thus, in this clinical preference study, DR was equivalent or even superior to the most modern dual read-out CR, even when obtained with 50% dose. A further dose reduction does not appear to be feasible for DR without significant loss of image quality. (orig.)

  7. Multiple image x-radiography for functional lung imaging

    Science.gov (United States)

    Aulakh, G. K.; Mann, A.; Belev, G.; Wiebe, S.; Kuebler, W. M.; Singh, B.; Chapman, D.

    2018-01-01

    Detection and visualization of lung tissue structures is impaired by predominance of air. However, by using synchrotron x-rays, refraction of x-rays at the interface of tissue and air can be utilized to generate contrast which may in turn enable quantification of lung optical properties. We utilized multiple image radiography, a variant of diffraction enhanced imaging, at the Canadian light source to quantify changes in unique x-ray optical properties of lungs, namely attenuation, refraction and ultra small-angle scatter (USAXS or width) contrast ratios as a function of lung orientation in free-breathing or respiratory-gated mice before and after intra-nasal bacterial endotoxin (lipopolysaccharide) instillation. The lung ultra small-angle scatter and attenuation contrast ratios were significantly higher 9 h post lipopolysaccharide instillation compared to saline treatment whereas the refraction contrast decreased in magnitude. In ventilated mice, end-expiratory pressures result in an increase in ultra small-angle scatter contrast ratio when compared to end-inspiratory pressures. There were no detectable changes in lung attenuation or refraction contrast ratio with change in lung pressure alone. In effect, multiple image radiography can be applied towards following optical properties of lung air-tissue barrier over time during pathologies such as acute lung injury.

  8. Radiological protection procedures for industrial applications of computed radiography

    International Nuclear Information System (INIS)

    Aquino, Josilto Oliveira de

    2009-03-01

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  9. Dual-energy subtraction radiography of the breast

    International Nuclear Information System (INIS)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-01-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses. (author)

  10. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  11. Neutron radiography for nondestructive testing

    International Nuclear Information System (INIS)

    John, J.

    1979-01-01

    Neutron radiography is similar to X-ray inspection in that both depend upon use of radiation that penetrates some materials and is absorbed by others to provide a contrast image of conditions not readily available for visual inspection. X-rays are absorbed by dense materials, such as metals, whereas neutrons readily penetrate metals, but are absorbed by materials containing hydrogen. The neutron radiography has been successfully applied to a number of inspection situations. These include the inspection of explosives, advanced composites, adhesively bonded structures and a number of aircraft engine components. With the availability of Californium-252, it has become feasible to construct mobile neutron radiography systems suitable for field use. Such systems have been used for in-situ inspection of flight line aircraft, particularly to locate and measure hidden corrosion

  12. An Intraoral Miniature X-ray Tube Based on Carbon Nanotubes for Dental Radiography

    Directory of Open Access Journals (Sweden)

    Hyun Jin Kim

    2016-06-01

    Full Text Available A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  13. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    International Nuclear Information System (INIS)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh

    2016-01-01

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube

  14. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-06-15

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  15. New north beam tube for the neutron radiography reactor

    International Nuclear Information System (INIS)

    Pruett, D.P.; Richards, W.J.; Heidel, C.C.

    1982-01-01

    Neutron radiography of the fuel undergoing examination in the argon cell is performed in the NRAD Facility and is one of many examinations performed on the fuel. The reactor and examination procedure are described. The new radiography system, developed to expand the present radiography capabilities to radiograph both irradiated and unirradiated specimens and to provide for the development of new radiography techniques without interfering with the argon cell production schedule is presented

  16. Quantitative film radiography

    International Nuclear Information System (INIS)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-01-01

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects

  17. Effects of tramadol or morphine in dogs undergoing castration on intra-operative electroencephalogram responses and post-operative pain.

    Science.gov (United States)

    Kongara, K; Chambers, J P; Johnson, C B; Dukkipati, V S R

    2013-11-01

    To compare the effects of pre-operatively administered tramadol with those of morphine on electroencephalographic responses to surgery and post-operative pain in dogs undergoing castration. Dogs undergoing castration were treated with either pre-operative morphine (0.5 mg/kg S/C, n = 8) or tramadol (3 mg/kg S/C, n = 8). All dogs also received 0.05 mg/kg acepromazine and 0.04 mg/kg atropine S/C in addition to the test analgesic. Anaesthesia was induced with thiopentone administered I/V to effect and maintained with halothane in oxygen. Respiratory rate, heart rate, end-tidal halothane tension (EtHal) and end-tidal CO2 tension (EtCO2) were monitored throughout surgery. Electroencephalograms (EEG) were recorded continuously using a three electrode montage. Median frequency (F50), total power (Ptot) and 95% spectral edge frequency (F95) derived from EEG power spectra recorded before skin incision (baseline) were compared with those recorded during ligation of the spermatic cords of both testicles. Post-operatively, pain was assessed after 1, 3, 6 and 9 h using the short form of the Glasgow composite measure pain scale (CMPS-SF). Dogs premedicated with tramadol had higher mean F50 (12.2 (SD 0.2) Hz) and lower Ptot (130.39 (SD 12.1) µv(2)) compared with those premedicated with morphine (11.5 (SD 0.2) Hz and 161.8 (SD 15.1) µv(2), respectively; p0.05). The F95 of the EEG did not differ between the two groups during the ligation of either testicle (p > 0.05). Post-operatively, no significant differences in the CMPS-SF score were found between animals premedicated with tramadol and morphine at any time during the post-operative period. No dog required rescue analgesia. Tramadol and morphine administered pre-operatively provided a similar degree of post-operative analgesia in male dogs at the doses tested.

  18. The evolving role of traditional birth attendants in maternal health in post-conflict Africa: A qualitative study of Burundi and northern Uganda.

    Science.gov (United States)

    Chi, Primus Che; Urdal, Henrik

    2018-01-01

    Many conflict-affected countries are faced with an acute shortage of health care providers, including skilled birth attendants. As such, during conflicts traditional birth attendants have become the first point of call for many pregnant women, assisting them during pregnancy, labour and birth, and in the postpartum period. This study seeks to explore how the role of traditional birth attendants in maternal health, especially childbirth, has evolved in two post-conflict settings in sub-Saharan Africa (Burundi and northern Uganda) spanning the period of active warfare to the post-conflict era. A total of 63 individual semi-structured in-depth interviews and 8 focus group discussions were held with women of reproductive age, local health care providers and staff of non-governmental organisations working in the domain of maternal health who experienced the conflict, across urban, semi-urban and rural settings in Burundi and northern Uganda. Discussions focused on the role played by traditional birth attendants in maternal health, especially childbirth during the conflict and how the role has evolved in the post-conflict era. Transcripts from the interviews and focus group discussions were analysed by thematic analysis (framework approach). Traditional birth attendants played a major role in childbirth-related activities in both Burundi and northern Uganda during the conflict, with some receiving training and delivery kits from the local health systems and non-governmental organisations to undertake deliveries. Following the end of the conflict, traditional birth attendants have been prohibited by the government from undertaking deliveries in both Burundi and northern Uganda. In Burundi, the traditional birth attendants have been integrated within the primary health care system, especially in rural areas, and re-assigned the role of 'birth companions'. In this capacity they undertake maternal health promotion activities within their communities. In northern Uganda, on

  19. Radiologic accidents in industrial gamma radiography - Brazilian cases

    International Nuclear Information System (INIS)

    Silva, Francisco Cesar Augusto da

    1997-01-01

    Three severe radiological accidents in industrial gamma radiography happened in Brazil during the period of 1985 to 1988. Five operators and nineteen public people were involved. These accidents caused some injuries in parts of the body, mainly hands and fingers. The main causes were faults in source monitoring, inadequate routine procedures and unknowing of radiation warning symbol by public people. The present paper shows the Brazilian cases of radiological accidents and makes some analysis of them. (author)

  20. Application of digital image processing to industrial radiography

    International Nuclear Information System (INIS)

    Bodson; Varcin; Crescenzo; Theulot

    1985-01-01

    Radiography is widely used for quality control of fabrication of large reactor components. Image processing methods are applied to industrial radiographs in order to help to take a decision as well as to reduce costs and delays for examination. Films, performed in representative operating conditions, are used to test results obtained with algorithms for the restauration of images and for the detection, characterisation of indications in order to determine the possibility of an automatic radiographs processing [fr

  1. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  2. Direct magnification radiography of the hand

    International Nuclear Information System (INIS)

    Presacco, D.; Pellegrini, A.; Di Maggio, C.

    1987-01-01

    The value of direct magnification radiography of the hand and the wrist has been studied in 128 patients affected by rheumatic diseases. Only in a small group (3.17%) magnification determined a higher percentage of correct diagnosis; in the 17.06% of cases direct magnification radiography provided useful increase in information but did not change the diagnisis correctly reached by conventional techniques. In most cases (79.76%) magnification provided only a better image quality but no more information helpful for the diagnosis, because of the high level achieved by convetional techniques. Therefore direct magnification radiography must be used only in selected cases and not as routine radiographyc technique

  3. Pediatric radiation dose management in digital radiography

    International Nuclear Information System (INIS)

    Neitzel, U.

    2004-01-01

    Direct digital radiography (DR) systems based on flat-panel detectors offer improved dose management in pediatric radiography. Integration of X-ray generation and detection in one computer-controlled system provides better control and monitoring

  4. Application of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Kobayashi, M.; Wada, N.; Sekita, J.; Sanno-cho, Ota-ku, Tokyo, Japan)

    1983-01-01

    The history and the present state of neutron radiography in Japan are reviewed. Three types of neutron sources, namely nuclear reactors, accelerators and radioisotopes are now used. The interests on the application on neutron radiography become greater and greater in the industries, such as atomic energy, aeronautics and space etc. (Auth.)

  5. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference.

    Science.gov (United States)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji

    2013-08-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.

  6. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2013-01-01

    Full Text Available Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS, four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360 were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC curve (Az were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively. The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631. Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.

  7. Reconfiguration of the NRAD delay loop for proposed 1 MW operations

    International Nuclear Information System (INIS)

    Heidel, C.C.; Richards, W.J.; Pruett, D.P.

    1984-01-01

    The Hot Fuel Examination Facility, HFEF, is one of several facilities located at the Argonne Site. HFEF comprises a large hot cell where both nondestructive and destructive examination of highly-irradiated reactor fuels are conducted in support of the LMFBR program. One of the nondestructive examination technqiues utilized at HFEF is neutron radiography. Neutron radiography is provided by the NRAD reactor facility, which is located beneath the HFEF hot cell. The NRAD reactor is a TRIGA reactor and is operated at a steady-state power level of 250 kw solely for neutron radiography and the development of radiography techniques. Modifications of the NRAD delay loop for 1 MW operations are described

  8. Collaboration in radiography: A bibliometric analysis

    International Nuclear Information System (INIS)

    Snaith, Beverly

    2012-01-01

    Introduction: Increasing research activity is an aim of the radiography profession, but there is a lack of knowledge of how this can be achieved. Collaboration between clinical and academic centres as well as between individuals has increased productivity in other professions and has been suggested as a strategy for radiography. This bibliometric study maps the current contribution to the radiography evidence base through a single journal. Method: All articles published in Radiography from 1997 to 2011 were reviewed to identify collaboration trends together with article type and subject. Analysis also enabled comparison of research and publication patterns. Results: 706 articles were published by 1205 individual authors. 63.0% were written by UK based authors, although this varied over time. Over 80% of authors published only single article. Two thirds of articles were collaborative with an increase in clinical-academic co-authorship over the 15 years of the study. Although the majority of articles were diagnostic imaging based, the pattern mirrors the UK workforce profile. Clinicians, including clinical-academic co-authors, tend to write about clinical practice and roles, whereas academics write about a broader range of topics. Conclusions: There has been a growth in research and scholarship within the UK radiography journal and both clinical and academic radiographers are contributing to the evidence base through increased collaboration.

  9. Radiation safety aspects in application of isotopes for industrial radiography in Bangladesh

    Energy Technology Data Exchange (ETDEWEB)

    Bakht, D. [Titas Gas Transmission and Distribution Company, Dhaka (Bangladesh)

    1997-10-01

    Industrial Radiography arose out of the widespread applications of X-rays pioneered by Roentgen about 100 years back. It is routinely used in studying the integrity of structural materials and like most countries in the world, its use in Bangladesh is increasing at a faster rate. This is because Bangladesh is a developing country of 3rd world and in the backdrop of agrarian poverty ridden economy, its population may exceed 125 millions by 2000 AD, leaving some 12 millions people unemployed. To support them, therefore, immense activities are activated in different sectors. Accordingly, increasing importance on NDT is given and in most cases particular application of Gamma radiography is preferred using Iridium Isotope Ir-192. Consequently the points of implications of isotopes are in Open Field and Inservice Inspection Radiography, Handling of Radiation Emergencies, Safe Transport of Radioactive Materials and Hazardous Effects and Risk of Ionizing Radiation, etc. Accordingly over exposure of Ir-192 Radionuclides, Accidents and Unusual Occurrences: Case Studies, Training Courses on Safety and Regulation of Sealed Sources, Licenses for Radiography Operation including Safe Disposal of Isotopes are the salient issues to be viewed in appropriate perspectives. The role played by Bangladesh Atomic Energy Commission and Bangladesh Society for NDT in collaboration with other members of the international committee for NDT are furthering the safe industrialization process

  10. Radiation safety aspects in application of isotopes for industrial radiography in Bangladesh

    International Nuclear Information System (INIS)

    Bakht, D.

    1997-01-01

    Industrial Radiography arose out of the widespread applications of X-rays pioneered by Roentgen about 100 years back. It is routinely used in studying the integrity of structural materials and like most countries in the world, its use in Bangladesh is increasing at a faster rate. This is because Bangladesh is a developing country of 3rd world and in the backdrop of agrarian poverty ridden economy, its population may exceed 125 millions by 2000 AD, leaving some 12 millions people unemployed. To support them, therefore, immense activities are activated in different sectors. Accordingly, increasing importance on NDT is given and in most cases particular application of Gamma radiography is preferred using Iridium Isotope Ir-192. Consequently the points of implications of isotopes are in Open Field and Inservice Inspection Radiography, Handling of Radiation Emergencies, Safe Transport of Radioactive Materials and Hazardous Effects and Risk of Ionizing Radiation, etc. Accordingly over exposure of Ir-192 Radionuclides, Accidents and Unusual Occurrences: Case Studies, Training Courses on Safety and Regulation of Sealed Sources, Licenses for Radiography Operation including Safe Disposal of Isotopes are the salient issues to be viewed in appropriate perspectives. The role played by Bangladesh Atomic Energy Commission and Bangladesh Society for NDT in collaboration with other members of the international committee for NDT are furthering the safe industrialization process

  11. Evaluation of Post-Operative Antibiotic Administration on Phenotypic ...

    African Journals Online (AJOL)

    But baseline data to judge effects of long-term post-operative antibiotic administration in clinical and surgical canine health conditions are currently lacking in Nigeria. This study aimed at providing vital baseline antibiotic profiles of canine bacteria of veterinary and public health importance. Phenotypic antibiotic susceptibility ...

  12. Proceedings of 7th short conference on neutron radiography

    International Nuclear Information System (INIS)

    Hiraoka, Eiichi; Katsurayama, Kousuke; Tsujimoto, Tadashi

    1986-10-01

    The first short period conference on neutron radiography was held in 1970, and now the 7th meeting was held. The works to develop neutron radiography in Japan are as active as those in western countries, and the research is in progress by using neutrons from reactors, radioisotopes and accelerators in order to achieve the technology of high standard. In this conference, 26 papers and six comments were presented, and the themes covered the equipment for radiography, the practical application, and the related research. The second World Conference on Neutron Radiography will be held in Paris in June, 1986, and the further promotion of the spread of neutron radiography can be expected. The proceedings of the conference is published with the hope that joint effort and information exchange are further enhanced in coming years to develop the neutron radiography in Japan. The neutron radiography using the Kinki University reactor, the Rikkyo Triga-2 reactor, the Musashi reactor, the Kyoto research reactor, a 3MV Van de Graaff accelerator in Toyota, a subcompact cyclotron in Sumitomo, a baby cyclotron-dual collimator in National Space Development Agency and so on, Cf-252 based thermal neutron radiography, CT with Sb-124/Be neutrons, pulse power neutron source, imaging converters, neutron radiographic image processing, computed tomography using neutron television systems and others are reported. (Kako, I.)

  13. Radiography of steel castings by radioisotopes

    International Nuclear Information System (INIS)

    Agrawal, D.K.

    1977-01-01

    The salient features of isotope radiography techniques in the inspections of alloy castings are described. Some of the typical radiographic tests conducted in the Bharat Heavy Electricals Ltd., Bhopal and the problems encountered are described in detail. Specific examples are cited to enlighten the benefits of isotope radiography in heavy industries. (author)

  14. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  15. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  16. Reduction of patient exposure during dental radiography

    International Nuclear Information System (INIS)

    Yulek, G.G.; Soydan, E.; Ugur, Z.

    1979-01-01

    The effect of using additional accessories with a conventional X-ray machine to reduce patient exposure during full-mouth dental radiography was investigated. LiF extruded-rod thermoluminescent dosimeters were placed in 23 anatomical sites of a Randophantom and the phantom was exposed to a Turkish dental X-ray machine operated at 60 kV, 10 mA for 0.5 sec periods. Maximum reductions were observed at the eyes (80%), in the thyroid (70.6%), under the collar bone (59.9% average) and the gonads (44.5%). (author)

  17. Detection of micro calcifications in breast specimen by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography

    International Nuclear Information System (INIS)

    Grunert, J.H.; Borchert, B.; Farber, A.; Gmelin, E.

    1999-01-01

    Aims of the study: The purpose of this study was to investigate the efficacy of 4-fold magnification breast specimen radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography in evaluating the presence of absence of carcinoma at the surgical margins by detection of microcalcification. Results: In 50 specimen 2821 (1305 within 3 mm distance to the margins) microcalcifications were detected with the DIMA mammography technique compared to 1608 (446) microcalcifications with the conventional technique. This increased detection rate by DIMA-magnetification radiography was accompanied by a decreased specificity in comparison to the conventional magnification radiography (33,3% DIMA versus 83,3% conventional) regarding the evaluation of presence or absence of carcinoma at the surgical margins. Differentiating the microcalcifications into calcifications belonging to the suspicious cluster and those that are located outside the cluster led to an increase in specificity (83,3% DIMA versus 100% conventional). Conclusions: The efficacy of breast specimens radiography in evaluating the presence or absence of carcinoma at the surgical margins by detection of microcalcification is not improved by 4-fold magnification radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography due to an increase in false-positive results. Analysis of the attachement of the microcalcifications to the cluster can improve the specificity. (orig.) [de

  18. A third generation mobile high energy radiography system

    International Nuclear Information System (INIS)

    Fry, D.A.; Valdez, J.E.; Johnson, C.S.; Kimerly, H.J.; Vananne, J.R.

    1997-01-01

    A third generation mobile high energy radiographic capability has been completed and put into service by the Los Alamos National Laboratory. The system includes a 6 MeV linac x-ray generator, Co-60 gamma source, all-terrain transportation, on-board power, real-time radiography (RTR), a control center, and a complete darkroom capability. The latest version includes upgraded and enhanced portability, flexibility, all-terrain operation, all-weather operation, and ease of use features learned from experience with the first and second generation systems. All systems were required to have the following characteristics; all-terrain, all-weather operation, self-powered, USAF airlift compatible, reliable, simple to setup, easy to operate, and all components two-person portable. The systems have met these characteristics to differing degrees, as is discussed in the following section, with the latest system being the most capable

  19. 10 CFR 34.13 - Specific license for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Specific license for industrial radiography. 34.13 Section 34.13 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION SAFETY... industrial radiography. An application for a specific license for the use of licensed material in industrial...

  20. Lateral radiography of the knee with single-leg standing

    International Nuclear Information System (INIS)

    Ohmori, Kan; Sugawara, Tsuyoshi; Murakami, Katsuyoshi; Kirinai, Mikio; Fujiwara, Junichi; Oikawa, Takumi; Matsumura, Yutaka; Sugawara, Tsukasa

    2002-01-01

    The purpose of this investigation was to accomplish reproducible radiography of single-leg standing lateral radiography of the knee by adjusting lateral rotation using a ruler to measure foot position. After preliminary assessment of three-dimensional CT of the knees of normal volunteers, the best adjustment of external rotation was estimated. A ruler was made for use in adjusting the angle of knee rotation by measuring foot rotation. Based on the foot rotation measured by this ruler, the positioning of radiography was adjusted to correct rotation. Rotation was estimated by the distance between the posterior edges of the lateral and medial femoral condyles. Fifteen-degree and 17.5-degree rotations were used for correction. Correction of rotation was 17 degrees on average. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate of lateral knee radiography. (author)

  1. Fundamental of neutron radiography and the present of neutron radiography in Japan

    International Nuclear Information System (INIS)

    Sekita, Junichiro

    1988-01-01

    Neutron radiography refers to the application of transmitted neutrons to analysis. In general, thermal neutron is used for neutron radiography. Thermal neutron is easily absorbed by light atoms, including hydrogen, boron and lithium, while it is not easily absorbed by such heavy atoms as tungsten, lead and uranium, permitting detection of impurities in heavy metals. Other neutrons than thermal neutron can also be applied. Cold neutron is produced from fast neutron using a moderator to reduce its energy down to below that of thermal neutron. Cold neutron is usefull for analysis of thick material. Epithermal neutron can induce resonance characteristic of each substance. With a relatively small reaction area, fast neutron permits observation of thick samples. Being electrically neutral, neutrons are difficult to detect by direct means. Thus a substance that releases charged particles is put in the path of neutrons for indirect measurement. X-ray film combined with converter screen for conversion of neutrons to charge particles is placed behind the sample. Photographing is carried out by a procedure similar to X-ray photography. Major institues and laboratories in Japan provided with neutron radiography facilities are listed. (Nogami, K.)

  2. Depth of anaesthesia and post-operative cognitive dysfunction

    DEFF Research Database (Denmark)

    Steinmetz, J; Funder, K S; Dahl, B T

    2010-01-01

    A deep level of anaesthesia measured by the bispectral index has been found to improve processing speed as one aspect of cognitive function after surgery. The purpose of the present study was to assess the possible effect of the level of anaesthesia on post-operative cognitive dysfunction (POCD) 1...

  3. Pseudomonas aeruginosa in Post-operative Wound Infections in ...

    African Journals Online (AJOL)

    The occurrence of post-operative wound infections was studied over a period of five months in the University College Hospital, Ibadan between February to July, 2003. Two hundred Surgical wounds were collected and routinely processed by Gram staining and culture in the Microbiology Laboratory. Of the 200 samples ...

  4. Post-operative computed tomographic imaging of the shoulder joint

    International Nuclear Information System (INIS)

    Helweg, G.; Zur Nedden, D.; Wicke, K.; Knapp, R.; Oberhauser, A.; Resch, H.; Sperner, G.

    1992-01-01

    Between 1984 and 1990 312 patients underwent surgery for habitual or recurrent shoulder dislocation. Out then, 65 had a post-operative CT examination. This retrospective study was launched to demonstrate the value of CT in post-operative shoulder imaging. In most cases, CT was done using standardised techniques without contrast medium. Except in 4 cases, an intra-articular double-contrast technique was used. Evaluation was focused on 41 cases after implantation of a wedged bone graft in cases of primary or secondary flat glenoid or widening of a small glenoid with cortical consoles and bone block. The results demonstrate the effectiveness of standardised CT technique in that all necessary information concerning stabilisation of the shoulder joint, sufficient implant of bone grafts and assessment of correct inclination after osteotomy were obtained. (orig.)

  5. Occurrence of pseudomonas aeruginosa in post-operative wound infection

    International Nuclear Information System (INIS)

    Oguntibeju, O.O.; Nwobu, R.A.U.

    2004-01-01

    Objective: To determine the prevalence of Pseudomonas aeruginosa in post-operative wound infection. Results: Out of the 60 bacterial isolates found in post-operative wound infection, 20 (33.3%) were Pseudomonas aeruginosa, followed by Staphylococcus aureus 13(21.7%), Klebsiella species 10(16.7%), Escherichia coli 7(11.7%), Atypical coliform 4(6.7%), Proteus species 4(6.7%), Streptococcus pyogenes 1(1.7%) and Enterococcus faecalis 1(1.7%) in the order. Pseudomonas aeruginosa infections was higher in female than male, ratio 3:2 and was found more among young and elderly debilitated patients. The in vitro sensitivity pattern of 20 isolates of Pseudomonas aeruginosa showed colistin (100%), gentamicin (75%), streptomycin (30%), and tetracycline (10%). Conclusion: The role of Pseudomonas aeruginosa as an agent of nosocomial infection is re-emphasised. (author)

  6. Skull Radiography

    Science.gov (United States)

    What you need to know about… Skull Radiography X-ray images of the skull are taken when it is necessary to see the cranium, facial bones or jaw bones. ... Among other things, x-ray exams of the skull can show fractures. Patient Preparation Before the examination, ...

  7. Radiography and bone scintigraphy in multiple myeloma: a comparative analysis

    International Nuclear Information System (INIS)

    Ludwig, H.; Kumpan, W.; Sinzinger, H.

    1982-01-01

    The sensitivity of radionuclide imaging for detecting skeletal lesions was compared with that of radiography by evaluating 573 different anatomical sites in 41 patients with multiple myeloma. Radiography revealed a significantly greater number of myeloma-related bone lesions than did radionuclide imaging. Of the 179 myeloma-related bone lesions detected when both techniques were applied, 163 were seen by radiography and 82 by radionuclide imaging. Ninety-seven lesions were detected by radiography alone and 16 lesions seen by scintiscanning only, yielding a sensitivity of 91% for the former and of 46% for the latter technique. Radionuclide imaging proved superior to radiography only occasionally in the rib cage, and rarely in other anatomical sites. These findings suggest that radiography is the method of first choice in obtaining a skeletal survey in patients with multiple myeloma. In cases with continued pain, unexplained by standard radiography, the skeletal survey should be supplemented by tomography and radionuclide imaging. (author)

  8. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Yoshitake [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan); Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio [Keio University School of Medicine, Department of Diagnostic Radiology, Tokyo (Japan); Abe, Takayuki [Keio University School of Medicine, Center for Clinical Research, Tokyo (Japan); Ogawa, Kenji [Nippon Koukan Hospital, Department of Radiology, Kawasaki-shi, Kanagawa (Japan)

    2013-08-15

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA{sub -950}) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA{sub -950}. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA{sub -950}. (orig.)

  9. Security of radioactive sources in industrial radiography

    International Nuclear Information System (INIS)

    Popp, Andrew; Murray, Allan

    2010-01-01

    This paper describes the need and new requirements to ensure the security of radioactive sources used in the practice of industrial radiography. We describe the discussions and issues arising during the september 2010 regional workshop held in Sydney on the application of security measures to industrial radiography practices. The workshop provided the perspectives of both radiation regulators and industry practitioners, including those from the Philippines. We describe the outputs of the workshop, and how they were developed, and make suggestions for further consideration and applications of security measures in the practice of industrial radiography. (author)

  10. Corrosion Surveillance In Pipe By Computed Radiography

    International Nuclear Information System (INIS)

    Nguyen The Man; Dao Duy Dung; Dang Thu Hong; Le Duc Thinh; Ha Hong Thu; Nguyen Trong Nghia

    2014-01-01

    Computed Radiography (CR) is a technique of digital industrial radiology which is developed to replace conventional radiography. With a CR system, the detection of the outer and inner wall surface of the pipe is done usually by edge detection and filter algorithms of the profile line at the position under investigation. Applying in industries, radiographic examination shall be performed in accordance with a written procedure. This paper summarizes collected knowledge and experimental results to establish a procedure for radiography applications in monitoring corrosion in small bore pipes. (author)

  11. Preparation and realization of industrial radiography for the non destructive testing of welds in Nuclear Power Plants: A spatial cognition analysis

    International Nuclear Information System (INIS)

    Lafon, M.; Tonnoir, S.; Thibault, G.; Lafon, M.; Berthoz, A.

    2008-01-01

    Controls of welds by radiographies are an efficient non destructive technique but it can be dangerous if not managed following a strict set of rules. EDF acts to avoid risks via several ways (adapted tools, best practices) and seeks for an integration of the radiographies with respect to the other maintenance operations, in order to raise the ratio of availability of the electricity production unit. This study explores an original analysis of industrial radiography: the influence of the representations of the workplace and its utilizations. This document supports the utilization of some space constraints as explanations of difficulties in the industrial radiography activity. The document proposes innovative points of view coming for on-site observations and from a theoretical background 'cognitive sciences' completed by technical propositions. (author)

  12. WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

    International Nuclear Information System (INIS)

    Gingold, E; Karellas, A; Strauss, K

    2014-01-01

    Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice

  13. WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Gingold, E [Thomas Jefferson University, Philadelphia, PA (United States); Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States); Strauss, K [Cincinnati Children' s Hospital Medical Center, Cincinnati, OH (United States)

    2014-06-15

    Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice

  14. TREAT neutron-radiography facility

    International Nuclear Information System (INIS)

    Harrison, L.J.

    1981-01-01

    The TREAT reactor was built as a transient irradiation test reactor. By taking advantage of built-in system features, it was possible to add a neutron-radiography facility. This facility has been used over the years to radiograph a wide variety and large number of preirradiated fuel pins in many different configurations. Eight different specimen handling casks weighing up to 54.4 t (60 T) can be accommodated. Thermal, epithermal, and track-etch radiographs have been taken. Neutron-radiography service can be provided for specimens from other reactor facilities, and the capacity for storing preirradiated specimens also exists

  15. Application of computed radiography to ERCP

    International Nuclear Information System (INIS)

    Lee, Shigeki; Mochizuki, Fukuji; Fujita, Naotaka; Itoh, Shoichiro; Ikeda, Takashi; Toyohara, Tokiaki; Matsumoto, Kyoichi

    1984-01-01

    Computed radiography technic was applied to ERCP. Fuji Computed Radiography System was used. The pancreatogram obtained by this method was compared with that of conventional screen-film radiograph. The much finer changes of the pancreatogram can be delineated by the new method. The diagnostic ability of ERCP is thus enhanced by the introduction of FCR. (author)

  16. Focusing mirrors for enhanced neutron radiography with thermal neutrons and application for irradiated nuclear fuel

    Science.gov (United States)

    Rai, Durgesh K.; Abir, Muhammad; Wu, Huarui; Khaykovich, Boris; Moncton, David E.

    2018-01-01

    Neutron radiography is a powerful method of probing the structure of materials based on attenuation of neutrons. This method is most suitable for materials containing heavy metals, which are not transparent to X-rays, for example irradiated nuclear fuel and other nuclear materials. Neutron radiography is one of the first non-distractive post-irradiated examination methods, which is applied to gain an overview of the integrity of irradiated nuclear fuel and other nuclear materials. However, very powerful gamma radiation emitted by the samples is damaging to the electronics of digital imaging detectors and has so far precluded the use of modern detectors. Here we describe a design of a neutron microscope based on focusing mirrors suitable for thermal neutrons. As in optical microscopes, the sample is separated from the detector, decreasing the effect of gamma radiation. In addition, the application of mirrors would result in a thirty-fold gain in flux and a resolution of better than 40 μm for a field-of-view of about 2.5 cm. Such a thermal neutron microscope can be useful for other applications of neutron radiography, where thermal neutrons are advantageous.

  17. Plain radiography, renography, and 99mTc-DMSA renal scintigraphy before and after extracorporeal shock wave lithotripsy for urolithiasis

    International Nuclear Information System (INIS)

    Munck, O.; Gerquari, I.; Moeller, J.T.; Jensen, L.I.; Thomsen, H.S.

    1992-01-01

    Eighteen patients were evaluated before and 5 weeks after the first treatment with extracorporeal shock wave lithotripsy (ESWL) using abdominal plain radiography, 131 I-hippuran probe renography, and 99m Tc-dimercaptosuccinic acid scintigraphy. In 6 patients no urolithiasis was present on the post ESWL plain radiograph, in 7 the size had decreased, and in 5 the stone mass was unchanged. The renograms were within normal range in the 6 patients who were cured by ESWL, whereas this was the case for only 4 of the 12 who still had renal calculi. In 2 patients pelvic stones had descended into the ureter after ESWL, and the renograms indicated obstruction. Another 3 patients had ureteral stones, whereas in the remaining 7 patients only pelvic stones were found on the plain radiographs. In no patient did the scintigrams reveal scars. It is concluded that abdominal plain radiography of the urinary tract and probe renography are complementary and sufficient in the monitoring of patients with urolithiasis post ESWL. (orig.)

  18. Test person operated 2-Alternative Forced Choice Audiometry compared to traditional audiometry

    DEFF Research Database (Denmark)

    Schmidt, Jesper Hvass; Brandt, Christian; Christensen-Dalsgaard, Jakob

      Background: With a newly developed technique, hearing thresholds can be estimated with a system operated by the test persons themselves. This technique is based on the 2 Alternative Forced Choice paradigm known from the psychoacoustic research theory. Test persons can operate the system very......-likelihood and up-down methods has proven effective and reliable even under suboptimal test settings. In non-optimal testing conditions i.e. as a part of a hearing conservation programme the headphone Sennheiser HDA-200 has been used as it contains hearing protection. This test-method has been validated......-retest studies of 2AFC audiometry are comparable to test-retest results known from traditional audiometry under standard clinical settings.   Conclusions 2 Alternative Forced Choice audiometry can be a reliable alternative to traditional audiometry especially under certain circumstances, where it can...

  19. Post-operative cognitive dysfunction in the elderly: A prospective clinical study

    Directory of Open Access Journals (Sweden)

    Nalini Kotekar

    2014-01-01

    Full Text Available Background and Aims: Aging population is a major demographic trend worldwide. Globally, 50% of all the elderly individuals are estimated to undergo atleast one surgical procedure and post-operative cognitive dysfunction (POCD is one of the most common and often poorly understood post-operative complications in this section of the population. This randomised prospective study was conducted to assess the post-operative cognitive status in the elderly undergoing non-cardiac surgery, evaluate the cognitive parameters affected, evaluate the potential risk factors and thereby analyse the potential for implementation of preventive strategies. Methods: This study was conducted on 200 patients aged 60 years or older scheduled for elective non-cardiac surgeries. The baseline cognitive status of the patients was assessed 2 days prior to the date of the surgery. The post-operative cognitive status was assessed on the 3 rd day, 7 th day and after 1 month. Statistical analysis was performed using SAS and SPSS. Results: The incidence of POCD showed a gradual decline from postoperative day 3 to 30. Females were found to be at significant risk in developing POCD. Advancing age and level of education emerged as dominant factors, while type of anaesthesia, duration of surgery, and presence of coexisting comorbidities had no influence on the incidence of cognitive dysfunction. Conclusion: POCD is a definite complication after surgery and anaesthesia in the elderly population. Gender emerged as a significant risk factor with increasing age as a dominating factor contributing to POCD.

  20. An improved fast neutron radiography quantitative measurement method

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2004-01-01

    The validity of a fast neutron radiography quantification method, the Σ-scaling method, which was originally proposed for thermal neutron radiography was examined with Monte Carlo calculations and experiments conducted at the YAYOI fast neutron source reactor. Water and copper were selected as comparative samples for a thermal neutron radiography case and a dense object, respectively. Although different characteristics on effective macroscopic cross-sections were implied by the simulation, the Σ-scaled experimental results with the fission neutron spectrum cross-sections were well fitted to the measurements for both the water and copper samples. This indicates that the Σ-scaling method could be successfully adopted for quantitative measurements in fast neutron radiography

  1. Radiography of X-ray in coral reefs

    International Nuclear Information System (INIS)

    Djoli Soembogo

    2016-01-01

    The application of X-ray radiography has been developed and it is already widely used in metal materials such as metal steel and carbon steel. This radiography using a source of radiation from X-ray machines. This research attempts to use the application of digital radiography X-ray source and use scanner Epson V700 positive films media for digitization results of conventional radiographic films on coral reefs. It has been testing radiography using Fuji film 100 to get the contrast medium, the sensitivity of the medium and image quality is good, Single Wall Single Image method , and using the media scanner films positive and X-ray sources, observation parameter are density radiographic film and the defect shape. Radiography uses Fuji film 100 to obtain a good contrast medium, good medium sensitivity and good quality image. Radiography of X-ray on coral reefs aims to find defects or discontinuities coral reefs such as porosity which would interfere with the determination of the age of the coral reefs. X-ray exposure time is 1 seconds for a thickness of 5.45 mm and 5.60 mm coral reefs by using a high voltage X-ray machine Rigaku of 130 kV. The result of the positive film scanner in the form of digital radiography that allows for the transfer of digital data or digital computerized data storage. The test results of radiographic on coral reefs with Single Wall Single Image method obtained radiographic film density parameter for Fuji film 100 on coral reefs No. 2 are 2.55; 2.53; 2.59 and on coral reefs No. 4 are 2.62; 2.65; 2.66, unsharpness geometric of radiographic results obtained 0.022 mm and 0.023 mm, sensitivity radiography are 1.648% and 1.604%. No defect found of Porosity that is significant. Status is acceptable for Fuji film 100, because the density of the film is in conformity with the standards referred to. Status of coral reefs No. 2 and No. 4 can be accepted, because it has conformed with the standards referred. (author)

  2. Feasibility study of gamma-ray medical radiography

    International Nuclear Information System (INIS)

    Alyassin, Abdalmajeid M.; Maqsoud, Hamza A.; Mashat, Ahmad M.; Al-Mohr, Al-Sayed; Abdulwajid, Subhan

    2013-01-01

    This research explores the feasibility of using gamma-ray radiography in medical imaging. We will show that gamma-ray medical radiography has the potential to provide alternative diagnostic medical information to X-ray radiography. Approximately one Ci Am-241 radioactive source which emits mono-energetic 59.5 keV gamma rays was used. Several factors that influence the feasibility of this study were tested. They were the radiation source uniformity, image uniformity, and image quality parameters such as contrast, noise, and spatial resolution. In addition, several gamma-ray and X-ray images were acquired using humanoid phantoms. These images were recorded on computed radiography image receptors and displayed on a standard monitor. Visual assessments of these images were then conducted. The Am-241 radioactive source provided relatively uniform radiation exposure and images. Image noise and image contrast were mainly dependent on the exposure time and source size, whereas spatial resolution was dependent on source size and magnification factor. The gamma-ray humanoid phantom images were of lower quality than the X-ray images mainly due to the low radioactivity used and not enough exposure time. Nevertheless, the gamma-ray images displayed most of the main structures contained in the humanoid phantoms. Higher exposure rates and thus lower exposure times were estimated for different pure Am-241 source sizes that are hypothesized to provide high quality images similar to X-ray images. For instance, a 10 mm source size of pure Am-241 with 7 s exposure time should produce images similar in contrast and noise to X-ray images. This research paves the way for the production and usage of a highly radioactive Am-241 source with the potential to lead to the feasibility of acceptable quality medical gamma-ray radiography. - Highlights: ► Characterized the performance of gamma-ray radiography. ► Displayed medical images of humanoid phantoms using gamma radiography. ► Am-241

  3. Post-operative telephone review is cost-effective and acceptable to patients.

    LENUS (Irish Health Repository)

    Gray, R T

    2012-02-01

    INTRODUCTION: Patients undergoing selective minor emergency and elective procedures are followed up by a nurse-led structured telephone review six weeks post-operatively in our hospital. Our study objectives were to review patients\\' satisfaction, assess cost-effectiveness and compare our practice with other surgical units in Northern Ireland (NI). PATIENTS AND METHODS: Completed telephone follow-up forms were reviewed retrospectively for a three-year period and cost savings calculated. Fifty patients were contacted prospectively by telephone using a questionnaire to assess satisfaction of this follow-up. A postal questionnaire was sent to 68 general and vascular surgeons in NI, assessing individual preferences for patient follow-up. RESULTS: A total of 1378 patients received a telephone review from September 2005 to September 2008. One thousand one hundred and seventy-seven (85.4%) were successfully contacted, while 201 (14.6%) did not respond despite multiple attempts. One hundred and forty-seven respondents (10.7%) required further outpatient follow-up, thereby saving 1231 outpatient reviews, equivalent to pound41,509 per annum. Thirty-nine (78%) patients expected post-operative follow-up, with 29 (58%) expecting this in the outpatient department. However, all patients were satisfied with the nurse-led telephone review. Fifty-three (78%) consultants responded. Those who always, or occasionally, review patients post-operatively varies according to the operation performed, ranging from 2.2% appendicectomy patients to 40.0% for varicose vein surgery. CONCLUSION: Current practice in NI varies, but a significant proportion of patients are not routinely reviewed. This study confirmed that patients expect post-operative follow-up. A nurse-led telephone review service is acceptable to patients, cost-effective and reduces the number of unnecessary outpatient reviews.

  4. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  5. Better imaging: the advantages of digital radiography

    NARCIS (Netherlands)

    van der Stelt, P.F.

    2008-01-01

    Background. Digital radiography has been available in dentistry for more than 25 years, but it has not replaced conventional film-based radiography completely. This could be because of the costs involved in replacing conventional radiographic equipment with a digital imaging system, or because

  6. Gravity sag view of lateral radiography of the knee

    International Nuclear Information System (INIS)

    Hidaka, Kuniyuki; Yanagawa, Yasuhiro; Kawamoto, Kiyosumi; Maeda, Daisuke; Komizu, Mitsuru

    2007-01-01

    The gravity sag view (GSV) is a lateral radiograph taken in the same position when the posterior sag sign is observed. The purpose of this study was to standardize the radiography technique for GSV by adjusting lateral rotation. To confirm the benchmark and correction angle (CA) for the GSV position, we assessed three-dimensional (3D) CT of the GSV position of the knee using normal volunteers. The benchmark is established at the 3-point of the leg and adjusting the CA of the knee is established by estimating from Rosenberg technique radiography. This helped not only to correct external rotation in the initial radiography but also to correct rotation for repeat radiography. Our method is quantitative and highly reproducible, and it increases the success rate in adjusting lateral radiography of the knee. (author)

  7. [Construction and realization of real world integrated data warehouse from HIS on re-evaluation of post-maketing traditional Chinese medicine].

    Science.gov (United States)

    Zhuang, Yan; Xie, Bangtie; Weng, Shengxin; Xie, Yanming

    2011-10-01

    To construct real world integrated data warehouse on re-evaluation of post-marketing traditional Chinese medicine for the research on key techniques of clinic re-evaluation which mainly includes indication of traditional Chinese medicine, dosage usage, course of treatment, unit medication, combined disease and adverse reaction, which provides data for reviewed research on its safety,availability and economy,and provides foundation for perspective research. The integrated data warehouse extracts and integrate data from HIS by information collection system and data warehouse technique and forms standard structure and data. The further research is on process based on the data. A data warehouse and several sub data warehouses were built, which focused on patients' main records, doctor orders, diseases diagnoses, laboratory results and economic indications in hospital. These data warehouses can provide research data for re-evaluation of post-marketing traditional Chinese medicine, and it has clinical value. Besides, it points out the direction for further research.

  8. Endobronchial Tuberculosis and Chest Radiography

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Sasani

    2016-03-01

    Full Text Available Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1 published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiography in the available patients were as follows: pulmonary consolidation (75%, reduced pulmonary volume (20%, and hilar adenopathy (10%. This is an incomplete statement because the authors did not explain whether there was any normal chest radiography in the study population. In addition, it is not clear whether the X-ray examinations of the patients were normal, how many abnormal plain films yielded the presented data. On the other hand, the fact that the studied patients had no normal chest radiography is  controversial since in the literature, 10-20% of the patients with endobronchial tuberculosis are reported to have normal chest X-ray (2, 3. In fact, this is one of the problems in the diagnosis of the disease, as well as a potential cause of delayed diagnosis and treatment of the patients. Therefore, the absence of normal chest radiographs is in contrast to the available literature, and if not an error, it could be a subject of further investigation.

  9. Opportunities for TRIGA reactors in neutron radiography

    International Nuclear Information System (INIS)

    Barton, John P.

    1978-01-01

    In this country the two most recent installations of TRIGA reactors have both been for neutron radiography, one at HEDL and the other at ANL. Meanwhile, a major portion of the commercial neutron radiography is performed on a TRIGA fueled reactor at Aerotest. Each of these installations has different primary objectives and some comparative observations can be drawn. Another interesting comparison is between the TRIGA reactors for neutron radiography and other small reactors that are being installed for this purpose such as the MIRENE slow pulse reactors in France, a U-233 fueled reactor for neutron radiography in India and the L88 solution reactor in Denmark. At Monsanto Laboratory, in Ohio, a subcritical reactor based on MTR-type fuel has recently been purchased for neutron radiography. Such systems, when driven by a Van de Graaff neutron source, will be compared with the standard TRIGA reactor. Future demands on TRIGA or competitive systems for neutron radiography are likely to include the pulsing capability of the reactor, and also the extraction of cold neutron beams and resonance energy beams. Experiments recently performed on the Oregon State TRIGA Reactor provide information in each of these categories. A point of particular current concern is a comparison made between the resonance energy beam intensity extracted from the edge of the TRIGA core and from a slot which penetrated to the center of the TREAT reactor. These results indicate that by using such slots on a TRIGA, resonance energy intensities could be extracted that are much higher than previously predicted. (author)

  10. Digital radiography: a survey of pediatric dentists.

    Science.gov (United States)

    Russo, Julie M; Russo, James A; Guelmann, Marcio

    2006-01-01

    The purpose of this study was to: (1) determine the popularity of digital radiography among members of the American Academy of Pediatric Dentistry (AAPD); and (2) report the most common systems in use. An AAPD-approved, voluntary, and anonymous electronic survey was developed and sent to 923 board certified pediatric dentists. Years in practice and in-office x-ray technology (digital or conventional) were inquired about initially. If negative for the use of digital radiography, future consideration for converting to digital radiography was ascertained. For positive responses, more in-depth information was requested. Information on type of system (sensor or phosphor plate), user friendliness, diagnostic ability, patient's comfort, general costs, durability, and parental and overall satisfaction was collected. For most of the questions, a 5-point assessment scale was used. Opportunity for additional comments was provided upon survey completion. Data was analyzed using descriptive statistics. A 32% (296/923) response rate was obtained. Twenty-six percent of practitioners (78/296) implemented digital radiography in their practices, whereas 71% considered future acquisition. Similar distribution for sensor and phosphor plate users was found. Sensor technology was reported to produce faster images, but was less tolerable by young children due to size and thickness. Phosphor plates were considered more children friendly, less expensive, and less durable. Parental satisfaction was very high with great marketing value. Picture quality was comparable to conventional film. Overall, digital radiography users would recommend it to other pediatric dentists. Digital radiography is not yet popular among pediatric dentists. Cost reduction and technology advancement may enhance utilization.

  11. A Novel Stress-Diathesis Model to Predict Risk of Post-operative Delirium: Implications for Intra-operative Management

    Directory of Open Access Journals (Sweden)

    Renée El-Gabalawy

    2017-08-01

    Full Text Available Introduction: Risk assessment for post-operative delirium (POD is poorly developed. Improved metrics could greatly facilitate peri-operative care as costs associated with POD are staggering. In this preliminary study, we develop a novel stress-diathesis model based on comprehensive pre-operative psychiatric and neuropsychological testing, a blood oxygenation level-dependent (BOLD magnetic resonance imaging (MRI carbon dioxide (CO2 stress test, and high fidelity measures of intra-operative parameters that may interact facilitating POD.Methods: The study was approved by the ethics board at the University of Manitoba and registered at clinicaltrials.gov as NCT02126215. Twelve patients were studied. Pre-operative psychiatric symptom measures and neuropsychological testing preceded MRI featuring a BOLD MRI CO2 stress test whereby BOLD scans were conducted while exposing participants to a rigorously controlled CO2 stimulus. During surgery the patient had hemodynamics and end-tidal gases downloaded at 0.5 hz. Post-operatively, the presence of POD and POD severity was comprehensively assessed using the Confusion Assessment Measure –Severity (CAM-S scoring instrument on days 0 (surgery through post-operative day 5, and patients were followed up at least 1 month post-operatively.Results: Six of 12 patients had no evidence of POD (non-POD. Three patients had POD and 3 had clinically significant confusional states (referred as subthreshold POD; ST-POD (score ≥ 5/19 on the CAM-S. Average severity for delirium was 1.3 in the non-POD group, 3.2 in ST-POD, and 6.1 in POD (F-statistic = 15.4, p < 0.001. Depressive symptoms, and cognitive measures of semantic fluency and executive functioning/processing speed were significantly associated with POD. Second level analysis revealed an increased inverse BOLD responsiveness to CO2 pre-operatively in ST-POD and marked increase in the POD groups when compared to the non-POD group. An association was also noted for

  12. Application of proton radiography to medical imaging

    International Nuclear Information System (INIS)

    Kramer, S.L.; Martin, R.L.; Moffett, D.R.; Colton, E.

    1977-12-01

    The use of charged particles for radiographic applications has been considered for some time, but progress has been impeded by the cost and availability of suitable accelerators. However, recent developments in technology could overcome these problems. A review is presented of the physical principles leading to an improvement in mass resolution per unit of absorbed dose for charged particle radiography relative to x-ray radiography. The quantitative comparisons between x-ray and proton radiographs presented here confirm this advantage. The implications of proton radiography on cancer detection, as well as future plans for developing a proton tomographic system, are discussed

  13. National reference doses for dental cephalometric radiography.

    Science.gov (United States)

    Holroyd, J R

    2011-12-01

    Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.

  14. A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Solayar GN

    2017-07-01

    Full Text Available INTRODUCTION: Optimal coronal and sagittal component positioning is important in achieving a successful outcome following total knee arthroplasty (TKA. Modalities to determine post-operative alignment include plain radiography and computer tomography (CT imaging. This study aims to determine the accuracy and reliability of plain radiographs in measuring coronal and sagittal alignment following TKA. MATERIALS AND METHODS: A prospective, consecutive study of 58 patients undergoing TKA was performed comparing alignment data from plain radiographs and CT imaging. Hip- knee-angle (HKA, sagittal femoral angle (SFA and sagittal tibial angle (STA measurements were taken by two observers from plain radiographs and compared with CT alignment. Intra- and inter-observer correlation was calculated for each measurement. RESULTS: Intra-observer correlation was excellent for HKA (r>0.89 with a mean difference of 0.95 and STA (r>0.8 compared to SFA (r=0.5. When comparing modalities (radiographs vs CT, HKA estimations for both observers showed the least maximum and mean differences while SFA observations were the least accurate. CONCLUSION: Radiographic estimation of HKA showed excellent intra- and inter-observer correlation and corresponds well with CT imaging. However, radiographic estimation of sagittal plane alignment was less reliably measured and correlated less with CT imaging. Plain radiography was found to be inferior to CT for estimation of biplanar prosthetic alignment following TKA.

  15. Post-operative delirium is associated with increased 5-year mortality.

    Science.gov (United States)

    Moskowitz, Eliza E; Overbey, Douglas M; Jones, Teresa S; Jones, Edward L; Arcomano, Todd R; Moore, John T; Robinson, Thomas N

    2017-12-01

    Post-operative delirium is associated with increased short term morbidity and mortality. Limited data exists on long term outcomes for older adults with postoperative delirium. We hypothesize that postoperative delirium is associated with increased 5-year mortality. Patients ≥50 years undergoing elective operations with planned intensive care unit (ICU) admissions were prospectively enrolled. The Confusion Assessment Method ICU (CAM-ICU) was used to diagnose delirium. The primary outcome variable was 5-year mortality. 172 patients were enrolled with an average age of 64 years. The overall incidence of delirium was 44% (75/172). At 5-years post-operatively, mortality was higher (59%, 41/70) in patients with delirium compared to patients without delirium (13%, 12/94, p delirium were 7.35 fold greater (95% CI: 1.49-36.18). Postoperative delirium is associated with increased long term mortality. Published by Elsevier Inc.

  16. The industrial radiography of defects inside the European Community

    International Nuclear Information System (INIS)

    Roeper, Burkhardt; Kaempf, B.

    1976-03-01

    The concept of the industrial radiography applied to defect invesigation is defined. The following topics are successively discussed: the development of the industrial 'defect radiography', apparatus and auxiliary equipments used in the field, the market, the constructors, trade currents in 'defect radiography' inside the Community and in the outer market; prognostics on future requirements in the fields

  17. Diagnostic value of digital radiography compared to conventional screen-film system combinations

    International Nuclear Information System (INIS)

    Krug, B.; Zaehringer, M.; Lackner, K.

    1997-01-01

    Digital projection radiography provides digital data in X-ray examinations, which used to be carried out by examinations screen-film system combinations. The technological basis and clinical performances of digital luminescent radiography (DLR) and digital radiography are reviewed. Digital projection radiography does not allow to reduce selenium exposure significantly, compared to screen-film system combinations. Digital luminescent radiography can be used for the entire spectrum of analogous projection radiography the only exception being extremely subtile structural changes. The clinical experiences with digital selenium radiography achieved so far in chest X-rays are promising and the technique is expected to be increasing used in other anatomic regions as well. (orig.) [de

  18. National data analysis of general radiography projection method in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam; Choi, In Seok [Dept. of Bio-Convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); and others

    2014-09-15

    According to database of medical institutions of health insurance review and assessment service in 2013, 1,118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

  19. Code of practice in industrial radiography

    International Nuclear Information System (INIS)

    Karma, S. E. M.

    2010-12-01

    The aim of this research is to developing a draft for a new radiation protection code of practice in industrial radiography without ignoring that one issued in 1998 and meet the current international recommendation. Another aim of this study was to assess the current situation of radiation protection in some of the industrial radiography department in Sudan. To achieve the aims of this study, a draft of a code of practice has been developed which is based on international and local relevant recommendations. The developed code includes the following main issues: regulatory responsibilities, radiation protection program and design of radiation installation. The practical part of this study includes scientific visits to two of industrial radiography departments in Sudan so as to assess the degree of compliance of that department with what state in the developed code. The result of each scientific visits revealed that most of the department do not have an effective radiation protection program and that could lead to exposure workers and public to unnecessary dose. Some recommendations were stated that, if implemented could improve the status of radiation protection in industrial radiography department. (Author)

  20. Post-operative morbidity of the obese patient undergoing posterior ...

    African Journals Online (AJOL)

    Outcome measures: Post-operative morbidity measures – infection, seroma, pulmonary embolism, urinary tract infection, neurological injury and dural tears. Methods: One hundred consecutive patients undergoing posterior lumbar spine surgery were enrolled in the study. Three fellowship trained attending orthopaedic ...

  1. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess; Thomas L. Maddock; Margaret A. Marshall; Leland M. Montierth

    2013-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has been evaluated as an acceptable benchmark experiment. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  2. Computed Radiography Exposure Indices in Mammography | Koen ...

    African Journals Online (AJOL)

    Computed Radiography Exposure Indices in Mammography. L Koen, C Herbst, W Rae. Abstract. Background. Studies indicate that computed radiography (CR) can lead to increased radiation dose to patients. It is therefore important to relate the exposure indicators provided by CR manufacturers to the radiation dose ...

  3. Safety relevant failure mechanisms in the post-operational phase; Sicherheitstechnisch relevante Fehlermechanismen in der Nachbetriebsphase

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, Gerhard; Stiller, Jan Christopher; Roemer, Sarah

    2017-03-15

    When the 13{sup th} amendment of the Atomic Energy Act came into force, eight Germ an nuclear power plant units had their power operating licences revoked and are now in the so-called post operation phase. Of the remaining nuclear power plants, one have by now also entered the post operation phase, with those left in operation bound for entering this phase sometime between now and the end of 2022. Therefore, failure mechanisms that are particularly relevant for post operation were to be identified and described in the frame of the present project. To do so, three major steps were taken: Firstly, recent national and international pertinent literature was evaluated to obtain indications of failure mechanisms in the post operation phase. It turned out that most of the national and international literature deals with the general procedure of the transition from power operation to decommissioning and dismantling. However, there were also some documents providing detailed indications of possible failure mechanisms in post operation. This includes e.g. the release of radioactive materials caused by the drop of containers, chemical impacts on systems important to safety in connection with decontamination work, and corrosion in connection with the storage of the core in the spent fuel pool, with the latter leading to the jamming of the fuel assemblies in the storage racks and a possible reduction of coolant circulation. In a second step, three safety analyses of pressurised water reactors prepared by the respective plant operators were evaluated to identify failure mechanisms based on systems engineering. The failure mechanisms that were found here include e.g. faults in the boric acid concentration of the reactor coolant, damage to the equipment airlock upon the unloading of Castor casks, leakages in connection with primary system decontamination, and the drop of packages holding radioactive residual materials or waste with subsequent mobilisation of radioactive aerosols

  4. Collective Inference based Data Analytics System for Post Operations Analysis, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Current-day capabilities for performing post operations analysis (POA) of air traffic operations at airports, airlines and FAA facilities are mostly limited to...

  5. Multi-energy radiography for non-destructive testing of materials and structures for civil engineering

    International Nuclear Information System (INIS)

    Naydenov, S.V.; Ryzhikov, V.

    2003-01-01

    Development of the technological base of modern non-destructive testing require new methods allowing determination of specified properties of materials and structures under study. A traditional direction of works is determination of internal spatial structure of the materials and other constructions. Restoration of this geometrical information is of qualitative character, though provides for determination of technical parameters affecting physical properties of the system. Reconstruction of the chemical composition, density and atomic structure (effective atomic number) is an inverse problem of direct quantitative determination of properties starting from data obtained by means of non-destructive testing. In the present work, we propose the use of multi-energy radiography for reconstruction of the substantial structure of materials. In framework of simple theoretical model it is shown that, using multi-channel absorption of X-rays, important substantial characteristics of materials and multi-compound structures can be readily reconstructed. The results obtained show high efficiency of 2-energy radiography for non-destructive testing in civil engineering

  6. Bacteriological research for the contamination of equipment in chest radiography

    International Nuclear Information System (INIS)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol

    2015-01-01

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections

  7. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  8. Post-operative treatment of endometrial carcinoma. Chapter 20

    International Nuclear Information System (INIS)

    Kuipers, Tj.; Star, W.M.

    1980-01-01

    The alternative forms of post-operative radiotherapy given in Rotterdam for endometrial carcinoma are described. Patients with infiltration involving less than half the thickness of the myometrium are treated with low dose-rate 137 Cs afterloading techniques. However, in patients with deep infiltration, a combination of high dose-rate Cathetron treatment and external irradiation is used. (U.K.)

  9. Depth of anaesthesia and post-operative cognitive dysfunction

    DEFF Research Database (Denmark)

    Steinmetz, J; Funder, K S; Dahl, B T

    2010-01-01

    A deep level of anaesthesia measured by the bispectral index has been found to improve processing speed as one aspect of cognitive function after surgery. The purpose of the present study was to assess the possible effect of the level of anaesthesia on post-operative cognitive dysfunction (POCD) 1...... week after surgery, as assessed by a neuropsychological test battery....

  10. Radiation-absorbed doses and energy imparted from panoramic tomography, cephalometric radiography, and occlusal film radiography in children

    International Nuclear Information System (INIS)

    Bankvall, G.; Hakansson, H.A.

    1982-01-01

    The absorbed doses and energy imparted from radiographic examinations of children, using panoramic tomography (PTG), cephalometric radiography (CPR), and maxillary frontal occlusal overview (FOO), were examined. The absorbed dose at various sites of the head were measured with TL dosimeters in a phantom and in patients. The energy imparted was calculated from measurements of areal exposure using a planparallel ionization chamber. The maximum absorbed doses for panoramic tomography were located around the lateral rotation center, for cephalometric radiography in the left (tube side) parotid region, and for frontal occlusal radiography in the nose. The absorbed doses in the eyes, thyroid gland, and skin are discussed and compared with previous reports and, for the most part, are found to be in agreement. The mean energy imparted from all three examination methods is 5 mJ with about 57 percent from panoramic, 33 percent from cephalometric, and 10 percent from frontal occlusal examinations. The energy imparted from cephalometric radiography can be reduced to about 10 percent with the use of an improved examination technique, leaving panoramic tomography responsible for contributing about 80 percent of the total energy imparted

  11. Reproducible positioning in chest X-ray radiography

    International Nuclear Information System (INIS)

    1974-01-01

    A device is described that can be used to ensure reproducibility in the positioning of the patient during X-ray radiography of the thorax. Signals are taken from an electrocardiographic monitor and from a device recording the respiratory cycle. Radiography is performed only when two preselected signals coincide

  12. Computed radiography versus mobile direct radiography for bedside chest radiographs: impact of dose on image quality and reader agreement

    NARCIS (Netherlands)

    de Boo, D. W.; Weber, M.; Deurloo, E. E.; Streekstra, G. J.; Freling, N. J.; Dongelmans, D. A.; Schaefer-Prokop, C. M.

    2011-01-01

    To asses the image quality and potential for dose reduction of mobile direct detector (DR) chest radiography as compared with computed radiography (CR) for intensive care unit (ICU) chest radiographs (CXR). Three groups of age-, weight- and disease-matched ICU patients (n=114 patients; 50 CXR per

  13. A fatal case of post-operative pulmonary thromboembolism with cosmetic liposuction.

    Science.gov (United States)

    Uemura, Koichi; Kikuchi, Yousuke; Shintani-Ishida, Kaori; Nakajima, Makoto; Yoshida, Ken-ichi

    2006-01-01

    Pulmonary thromboembolism (PTE) has been regarded as rare in Japan. However, PTE has been increasingly recognised because either of increased incidence, diagnostic progress, or social recognition. Recently, 10 Japanese Medical Associations have submitted preventive guidelines for PTE in post-operative patients and the government decided to fund this, as results of the increase in cases and concern regarding medical negligence. A fatal case of PTE after liposuction is reported. A female patient was in the home toilet after two days of immobilization following day-surgery liposuction. Clinicians must be aware of appropriate methods for the prevention of post operative PTE with cosmetic surgery.

  14. Visualization of frosting phenomena by using neutron radiography

    International Nuclear Information System (INIS)

    Yoshimura, Tomoya; Matsumoto, Ryosuke; Umekawa, Hisashi; Ami, Takeyuki; Saito, Yasushi

    2012-01-01

    This study focuses on the frost formation on the fin-tube heat exchanger using neutron radiography. The visualization of the frost formation was estimated by the attenuation of the neutron beam through the water. The visualization image of the neutron radiography shows clearly the frost formation phenomena on the fin-tube heat exchanger. The rapid frost formation was observed at the fin and tube edges. Local mass transfer coefficient can be calculated from the differential images of the neutron radiography. (author)

  15. Predictors of post operative bleeding and blood transfusion in ...

    African Journals Online (AJOL)

    blood requirements. Objective: To evaluate the impact of some perioperative predictors of post-operative bleeding, and blood transfusion after heart surgery and offer suggestions on preventive measures. Design and Methods: A prospective analytical study. The perioperative factors studied were haemoglobin level, ...

  16. 10 CFR 34.42 - Radiation Safety Officer for industrial radiography.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Radiation Safety Officer for industrial radiography. 34.42 Section 34.42 Energy NUCLEAR REGULATORY COMMISSION LICENSES FOR INDUSTRIAL RADIOGRAPHY AND RADIATION... Radiation Safety Officer for industrial radiography. The RSO shall ensure that radiation safety activities...

  17. Safety guide of safe use of industrial radiography

    International Nuclear Information System (INIS)

    1994-01-01

    The objective of this guidance is to present general regulations for the safe use and radiation protection of industrial radiography. Storage and inspection of apparatus, personal instructions for working in radiography facilities are offered

  18. Radiography technique

    Energy Technology Data Exchange (ETDEWEB)

    Panaiotov, L N

    1951-10-23

    A new method of hollow articles radiography is presented enabling to eliminate shortcomings coupled with medical personnel irradiation when the ampoule incorporating radioactive substance is removed from the protective container and adjusted in the article. The method presented permits to transport the ampoule from the protective container immediately into the inner cavity of the article.

  19. Pre-operative use of anti-TNF-alpha agents and the risk of post-operative complications in patients with Crohn's disease--a nationwide cohort study

    DEFF Research Database (Denmark)

    Nørgård, Bente Mertz; Nielsen, J.; Qvist, N.

    2013-01-01

    BACKGROUND: A possible negative role of pre-operative use of antitumour necrosis factor-alpha (anti-TNF-alpha) agents on post-operative outcomes in Crohn's disease (CD) patients is still debated. AIM: To examine the impact of pre-operative anti-TNF-alpha agents on post-operative outcomes 30 and 6...

  20. Controlling Acute Post-operative Pain in Iranian Children with using of Music Therapy

    Directory of Open Access Journals (Sweden)

    Mojtaba Miladinia

    2016-05-01

    Full Text Available Background: Despite the development of pediatric post-operative pain management and use of analgesic/narcotic drugs, post-operative pain remains as a common problem. Some studies suggested, the most effective approach to controlling immediate post-operative pain may include a combination of drug agents and non-drug methods. The aim of this study was to investigate the effect of music therapy on the acute post-operative pain in Iranian children.  Materials and Methods: A quasi-experimental, repeated measure design was used. In this study, 63 children were placed in the music and control groups. In the music group, pain intensity was measured before start intervention (baseline. Then, this group listened to two non-speech music for 20 minutes. Then, pain intensity was measured with numeric rating scale, immediately after intervention, 1 hour, 3 hours and 6 hours after intervention, respectively. Also, in the control group, pain intensity was measured in times similar to music group. Results: The mean of pain intensity did not significantly different between the 2 groups at baseline (P>0.05. The results of repeated measure ANOVA showed that, trend of pain intensity between 2 groups was significant (P

  1. Assessment of medial elbow laxity by gravity stress radiography: comparison of valgus stress radiography with gravity and a Telos stress device.

    Science.gov (United States)

    Harada, Mikio; Takahara, Masatoshi; Maruyama, Masahiro; Nemoto, Tadanobu; Koseki, Kazuhiko; Kato, Yoshihiro

    2014-04-01

    Valgus instability was reported to be higher with the elbow in 60° of flexion, rather than in 30° of flexion, although there are no studies using valgus stress radiography by gravity (gravity radiography) with the elbow in 60° of flexion. Fifty-seven patients with medial elbow pain participated. For both elbows, valgus stress radiography by use of a Telos device (Telos radiography) and gravity radiography, with the elbow in 60° of flexion, were performed for the assessment of medial elbow laxity. In both radiographs, the medial elbow joint space (MJS) on the affected side was compared with that on the opposite side, and the increase in the MJS on the affected side was assessed. For the Telos radiographs, the mean MJS was 4.7 mm on the affected side and 4.0 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.7 mm. For the gravity radiographs, the mean MJS was 5.0 mm on the affected side and 4.2 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.8 mm. There were significant correlations between the Telos and gravity radiographs in the MJS on the affected side, the MJS on the opposite side, and the increase in the MJS on the affected side (respectively, P gravity radiographs. Gravity radiography is useful for assessment of medial elbow laxity, similar to Telos radiography. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  2. Early versus delayed post-operative bathing or showering to prevent wound complications.

    Science.gov (United States)

    Toon, Clare D; Sinha, Sidhartha; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2015-07-23

    Many people undergo surgical operations during their life-time, which result in surgical wounds. After an operation the incision is closed using stiches, staples, steri-strips or an adhesive glue. Usually, towards the end of the surgical procedure and before the patient leaves the operating theatre, the surgeon covers the closed surgical wound using gauze and adhesive tape or an adhesive tape containing a pad (a wound dressing) that covers the surgical wound. There is currently no guidance about when the wound can be made wet by post-operative bathing or showering. Early bathing may encourage early mobilisation of the patient, which is good after most types of operation. Avoiding post-operative bathing or showering for two to three days may result in accumulation of sweat and dirt on the body. Conversely, early washing of the surgical wound may have an adverse effect on healing, for example by irritating or macerating the wound, and disturbing the healing environment. To compare the benefits (such as potential improvements to quality of life) and harms (potentially increased wound-related morbidity) of early post-operative bathing or showering (i.e. within 48 hours after surgery, the period during which epithelialisation of the wound occurs) compared with delayed post-operative bathing or showering (i.e. no bathing or showering for over 48 hours after surgery) in patients with closed surgical wounds. We searched The Cochrane Wounds Group Specialised Register (30th June 2015); The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); The Database of Abstracts of Reviews of Effects (DARE) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE; EBSCO CINAHL; the metaRegister of Controlled Trials (mRCT) and the International Clinical Trials Registry Platform (ICTRP). We considered all randomised trials conducted in patients who had undergone any surgical procedure and had surgical closure of

  3. Post-operative serious adverse events in a mixed surgical population

    DEFF Research Database (Denmark)

    Hansen, M S; Petersen, E E; Dahl, J B

    2016-01-01

    BACKGROUND: The number of surgical procedures is increasing, and knowledge of surgical risk factors, post-operative mortality and serious adverse events (SAE) is essential. The aim with our study was to determine the risk of a composite outcome of post-operative: death; myocardial infarction...... or gynaecological surgery was conducted retrieving data from The Danish Civil Registration System and the National Patient Register. Total observation time was from January 1, 2012 to June 6, 2013. RESULTS: A total7449 adult patients were included in the final analysis. The risk of the composite outcome during...... of 8.3% (7.8-9.0). The results are applicable in estimations of adequate sample sizes in future clinical trials investigating effects of interventions on SAEs....

  4. Heavy-ion radiography

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Tobias, C.A.; Holley, W.R.; Benton, E.V.

    1981-01-01

    Heavy-particle radiography has clinical potential as a newly developed noninvasive low-dose imaging procedure that provides increased resolution of minute density differences in soft tissues of the body. The method utilizes accelerated high-energy ions, primarily carbon and neon, at the Bevalac accelerator at the Lawrence Berkeley Laboratory. The research program for medicine utilizes heavy-ion radiography for low-dose mammography, for treatment planning for cancer patients, and for imaging and accurate densitometry of skeletal structures, brain and spinal neoplasms, and the heart. The potential of heavy-ion imaging, and particularly reconstruction tomography, is now proving to be an adjunct to existing diagnostic imaging procedures in medicine, both for applications to the diagnosis, management and treatment of clinical cancer in man, and for the early detection of small soft-tissue tumors at low radiation dose

  5. Constancy tests radiography X-ray devices with CR system

    International Nuclear Information System (INIS)

    Durdikova, M.; Zakova, M.

    2005-01-01

    The paper presents the changes in QAP (Quality Assurance Program) as consequence of digitalisation of medical facilities. Digitalisation brings many advantages - more comfort for personal use, images are easy achievable and transferable to workstation, fine quality images by postprocessing are easily achievable. But it must be taken into account that due to simplicity of image make it is sometimes taken more images then necessary .There are two possible ways of digitalisation in radiography: to exchange conventional developer machine by Computer Radiography (CR), that means to use CR reader and cassette with phosphor plate - un-direct digitalisation or to use special radiography X-ray devices with flat-panel detector -direct radiography. (authors)

  6. Contribution of computed tomography in patients with lung metastases of differentiated thyroid carcinoma not apparent on plain radiography who were treated with radioiodine

    International Nuclear Information System (INIS)

    Rosario, Pedro W.S.; Purisch, Saulo; Barroso, Alvarao L.; Rezende, Leonardo L.; Padrao, Eduardo L.

    2008-01-01

    Computed tomography (CT or CAT Scan) of the chest is more sensitive than radiography in the detection of lung metastases of differentiated thyroid cancer (DTC), but little information is available regarding the aggregated value of this method. The present study evaluated the response of patients with lung metastases of DTC not apparent on radiography to treatment with 131 I and the value of CT in these cases. Twenty-five patients with lung metastases not apparent on radiography, who initially received 100-200 mCi I 151 , were evaluated and those presenting pulmonary uptake on post-therapy WBS were submitted to a new treatment after 6 to 12 months, and so on. The chance of detection of pulmonary uptake on post-therapy WBS did not differ between patients with negative and positive CT (100% versus 91.5%). Mean serum Tg levels were higher in patients with positive CT (108 ng/ml versus 52 ng/ml). Negative post-therapy WBS was achieved in 82% of patients with positive CT and in 92.3% with negative CT and the cumulative I 131 activity necessary to achieve this outcome did not differ between the two groups (mean = 300 mCi). Stimulated Tg was undetectable in 47% of patients with negative CT at the end of treatment, but in none of the patients whose CT continued to be positive. In patients with elevated Tg, the CT result apparently did not change the indication of therapy or the I 131 activity to be administered. In cases with lung metastases, the persistence of micronodules on CT was associated with the persistence of detectable Tg in patients presenting negative post-therapy WBS. (author)

  7. Post-operative pain management in paediatric surgery at Sylvanus Olympio University Teaching Hospital, Togo

    Directory of Open Access Journals (Sweden)

    Hamza Doles Sama

    2014-01-01

    Full Text Available Background: The aim of this study was to evaluate pain management in paediatric surgery at Sylvanus Olympio University Teaching Hospital, Lome. Patients and Methods: A prospective descriptive study was conducted in the Department of Anaesthesiology and Intensive Care at Sylvanus Olympio teaching hospital from 1 January to 30 June 2012. Data collected include: demography, type of surgery, American Society of Anaesthesiologists (ASA classification, anaesthetic protocol, analgesia technique, post-operative complications and cost of analgesia. Results: The study includes 106 post-operative children. Abdominal surgery was performed in 41.5% and orthopaedic surgery in 31.1%. A total of 75% of patients were classified ASA 1. General anaesthesia (GA was performed in 88%. Anaesthetists supervised post-operative care in 21.7% cases. Multimodal analgesia was used in every case and 12% of patients received a regional block. The most frequently unwanted effects of analgesics used were nausea and/or vomiting in 12.3%. At H24, child under 7 years have more pain assessment than those from 7 to 15 years (46% vs 24% and this difference was statistically significant (chi-square = 4.7598; P = 0.0291 < 0.05. The average cost of peri-operative analgesia under loco regional analgesia (LRA versus GA during the first 48 h post-operative was US $23 versus $46. Conclusion: Our study showed that post-operative pain management in paediatric surgery is often not well controlled and paediatric loco regional analgesia technique is under practiced in sub Saharan Africa.

  8. Compton radiography, 4. Magnification compton radiography

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, S; Sera, K; Shishido, F; Fukuda, H [Tohoku Univ., Sendai (Japan). Research Inst. for Tuberculosis and Cancer; Mishina, H

    1978-03-01

    Compton radiography permits an acquisition of direct magnification Compton radiograms by use of a pinhole collimator, rendering it feasible to overcome the resolution of the scinticamera being employed. An improvement of resolution was attained from 7 mm to 1 mm separation. Usefulness of its clinical application can be seen in orientation of puncture and biopsy in deep structures and detection of various foreign bodies penetrated by blasts and so on under the ''magnification Compton fluoroscopy'' which can be developed on this principle in the near future.

  9. Time-grated energy-selected cold neutron radiography

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Brun, T.O.; Claytor, T.N.; Farnum, E.H.; Greene, G.L.; Morris, C.

    1998-01-01

    A technique is under development at the Los Alamos Neutron Science Center (LANSCE), Manuel Lujan Jr. Neutron Scattering Center (Lujan Center) for producing neutron radiography using only a narrow energy range of cold neutrons. The technique, referred to as Time-Gated Energy-Selected (TGES) neutron radiography, employs the pulsed neutron source at the Lujan Center with time of flight to obtain a neutron pulse having an energy distribution that is a function of the arrival time at the imager. The radiograph is formed on a short persistence scintillator and a gated, intensified, cooled CCD camera is employed to record the images, which are produced at the specific neutron energy range determined by the camera gate. The technique has been used to achieve a degree of material discrimination in radiographic images. For some materials, such as beryllium and carbon, at energies above the Bragg cutoff the neutron scattering cross section is relatively high while at energies below the Bragg cutoff the scattering cross section drops significantly. This difference in scattering characteristics can be recorded in the TGES radiography and, because the Bragg cutoff occurs at different energy levels for various materials, the approach can be used to differentiate among these materials. This paper outlines the TGES radiography technique and shows an example of radiography using the approach

  10. Digital radiography in space.

    Science.gov (United States)

    Hart, Rob; Campbell, Mark R

    2002-06-01

    With the permanent habitation of the International Space Station, the planning of longer duration exploration missions, and the possibility of space tourism, it is likely that digital radiography will be needed in the future to support medical care in space. Ultrasound is currently the medical imaging modality of choice for spaceflight. Digital radiography in space is limited because of prohibitive launch costs (in the region of $20,000/kg) that severely restrict the volume, weight, and power requirements of medical care hardware. Technological increases in radiography, a predicted ten-fold decrease in future launch costs, and an increasing clinical need for definitive medical care in space will drive efforts to expand the ability to provide medical care in space including diagnostic imaging. Normal physiological responses to microgravity, in conjunction with the high-risk environment of spaceflight, increase the risk of injury and could imply an extended recovery period for common injuries. The advantages of gravity on Earth, such as the stabilization of patients undergoing radiography and the drainage of fluids, which provide radiographic contrast, are unavailable in space. This creates significant difficulties in patient immobilization and radiographic positioning. Gravity-dependent radiological signs, such as lipohemarthrosis in knee and shoulder trauma, air or fluid levels in pneumoperitoneum, pleural effusion, or bowel obstruction, and the apical pleural edge in pneumothorax become unavailable. Impaired healing processes such as delayed callus formation following fracture will have implications on imaging, and recovery time lines are unknown. The confined nature of spacecraft and the economic impossibility of launching lead-based personal protective equipment present significant challenges to crew radiation safety. A modified, free-floating radiographic C-arm device equipped with a digital detector and utilizing teleradiology support is proposed as a

  11. Comparison of a Distributed Operations Force to a Traditional Force in Urban Combat

    National Research Council Canada - National Science Library

    Babilot, Michael

    2005-01-01

    ...). The employment of a DO is compared to employment of a traditional Marine infantry platoon in an urban combat scenario based upon data obtained from Operation al-Fajr, conducted in Fallujah, Iraq, in November 2004...

  12. Post-operative Wound Site Infection Caused by Nocardia species

    Directory of Open Access Journals (Sweden)

    Sunayana M. Jangla

    2018-04-01

    Full Text Available A61 year old diabetic female who was a known case of breast carcinoma and had undergone mastectomy was admitted with discharge from the post-operative wound site. Nocardia species was isolated from the discharge. She responded to treatment with trimethoprim-sulfamethoxazole.

  13. Radiation protection in dental radiography

    International Nuclear Information System (INIS)

    Jozani, F.; Parnianpour, H.

    1976-08-01

    In considering the special provisions required in dental radiography, investigations were conducted in Iran. Radiation dose levels in dental radiography were found to be high. Patient exposure from intraoral radiographic examination was calculated, using 50kV X-ray. Thermoluminescent dosimeters were fastened to the nasion, eyes, lip, philtrum, thyroid, gonads and to the right and left of the supra-orbital, infra-orbital temporomandibular joints of live patients. The highest exposure value was for the lower lip. Recommendations concerning educational training and protection of staff and patients were included

  14. Educational aspects of industrial radiography

    International Nuclear Information System (INIS)

    Krishnamurthy, K.; Wamorkar, R.R.; Singh, G.

    1979-01-01

    The state of art of training and education in non-destructive testing in India, with special reference to industrial radiography is reviewed. Basic requirement of industry and potential of radioisotopes in industrial inspection are also described. Need for an organised training programme in industrial isotope radiography to exploit potentials for benefit of industry concurrent with the safety is stressed. A comprehensive training programme tailored to meet the needs of Indian industry is outlined. Benefits obtained from the course to the industry since the beginning of the training programme are briefly reviewed. (auth.)

  15. Muon radiography method for fundamental and applied research

    Science.gov (United States)

    Alexandrov, A. B.; Vladymyrov, M. S.; Galkin, V. I.; Goncharova, L. A.; Grachev, V. M.; Vasina, S. G.; Konovalova, N. S.; Malovichko, A. A.; Managadze, A. K.; Okat'eva, N. M.; Polukhina, N. G.; Roganova, T. M.; Starkov, N. I.; Tioukov, V. E.; Chernyavsky, M. M.; Shchedrina, T. V.

    2017-12-01

    This paper focuses on the basic principles of the muon radiography method, reviews the major muon radiography experiments, and presents the first results in Russia obtained by the authors using this method based on emulsion track detectors.

  16. Studies on the Fuji computed radiography depended on the panoramic radiography

    International Nuclear Information System (INIS)

    Nakamura, Satoshi; Shiota, Satoru; Takazawa, Kazuyoshi; Yoshida, Toru; Takagi, Yoshiko; Funamoto, Choichiro

    1986-01-01

    The Fuji Computed Radiography (FCR) developed recently involves the following procedures; photography in the same way as the hitherto radiography, printing auto imaging plate of photostimulable phospher, conversion to electric signals, and recording reproduced images by computerization. Highly valuable images for diagnoses in the medical field have already been obtained by the FCR. Then, we attempted to study FCR images panoramically radiographed for jaw lesions in the field of oral surgery. Method for study: As the samples to be studied, the selected subjects were cases of periodontal diseases, fracture of the jaw, odontogenic cyst and tumor, etc. In the present study the FCR images of panoramic radiography were compared with hitherto panoramic flat radiograms. Result of study: Although the images of the FCR vary depending on the methods of treatment, that is, on how gradient processing and spatial frequency enhancement are, the method of purpose-fitting treatment provided diagnostically significant images for grasping bone lesions. The images obtained from this FCR permitted us to grasp more distinctly condition of alveolar bone resorption in periodontal diseases, running of minute fracture lines in fracture of the jaw, and characteristic images of bone resorption in odontogenic cysts and tumor, etc. Thus the images of the FCR are highly useful in diagnosing bone lesions, but granularity of the images themselves have still been questioned, and additionally the images vary depending on the methods of gradient processing and spatial frequency enhancement. Therefore further repeat studies are probably needed for these questions. (author)

  17. The application of microfocal radiography to neuroanatomy and neuropathology research, and its relation to cerebral magnification angiography and brain scan interpretation. Chapter 3

    International Nuclear Information System (INIS)

    Saunders, R.L. de C.H.

    1980-01-01

    Microfocal radiography is used to study post mortem, the microcirculatory and neuronal organization of the normal and diseased brain, as well as to interpret the images obtained clinically by the new techniques of cerebral magnification angiography and X-ray brain scanning. An outline of the basic technique underlying CT scanning and magnification radiography of the living human brain is given to facilitate the understanding of why microfocal radiography is central to magnification radiography and complementary to CT scanning. Microangiography, one of the microfocal radiographic techniques, is discussed at length in relation to the microvasculature of the human cerebral cortex, the vasculature of the subcortical or medullary white matter, the microvascular patterns of the central grey matter and internal capsule, the vascular patterns of the visual cortex and hippocampus; the application of microangiography to the spinal cord and nerve roots is also discussed. Another microfocal radiographic technique described is cerebral historadiography, i.e. X-ray studies of brain histology, with particular reference to the human hippocampal formation. Finally, the correlation of microfocal X-ray and brain CT scan images is discussed. (U.K.)

  18. Projection radiography and tomography

    International Nuclear Information System (INIS)

    Tobias, C.A.; Fabrikant, J.I.; Benton, E.V.; Holley, W.R.

    1980-01-01

    Our program on heavy-ion radiography began soon after heavy ions were accelerated to high energies. Heavy ions are capable of very high electron density discrimination combined with good radial image resolution and low dose. Since heavy-ion beams produce many secondries, plastic nuclear detectors have an advantage for recording heavy-ion images. Projection imaging is now a practical technique that can resolve density differences between normal tissue and tumor tissue in some cases in which X rays could not make a distinction. Initial attempts at heavy-ion tomography also indicate potential for high resolution in this field. The physical basis for heavy-ion radiography and tomographic reconstruction studies are discussed in detail

  19. Pre-operative use of anti-TNF-α agents and the risk of post-operative complications in patients with ulcerative colitis - a nationwide cohort study

    DEFF Research Database (Denmark)

    Nørgård, B M; Nielsen, J; Qvist, N

    2012-01-01

    It is still controversial whether pre-operative anti-tumour necrosis factor-alpha (anti-TNF-α) agents increase post-operative complications in patients with ulcerative colitis (UC).......It is still controversial whether pre-operative anti-tumour necrosis factor-alpha (anti-TNF-α) agents increase post-operative complications in patients with ulcerative colitis (UC)....

  20. Review of medical radiography and tomography with proton beams

    Science.gov (United States)

    Johnson, Robert P.

    2018-01-01

    The use of hadron beams, especially proton beams, in cancer radiotherapy has expanded rapidly in the past two decades. To fully realize the advantages of hadron therapy over traditional x-ray and gamma-ray therapy requires accurate positioning of the Bragg peak throughout the tumor being treated. A half century ago, suggestions had already been made to use protons themselves to develop images of tumors and surrounding tissue, to be used for treatment planning. The recent global expansion of hadron therapy, coupled with modern advances in computation and particle detection, has led several collaborations around the world to develop prototype detector systems and associated reconstruction codes for proton computed tomography (pCT), as well as more simple proton radiography, with the ultimate intent to use such systems in clinical treatment planning and verification. Recent imaging results of phantoms in hospital proton beams are encouraging, but many technical and programmatic challenges remain to be overcome before pCT scanners will be introduced into clinics. This review introduces hadron therapy and the perceived advantages of pCT and proton radiography for treatment planning, reviews its historical development, and discusses the physics related to proton imaging, the associated experimental and computation issues, the technologies used to attack the problem, contemporary efforts in detector and computational development, and the current status and outlook.

  1. Tomosynthesis for the early detection of pulmonary emphysema: diagnostic performance compared with chest radiography, using multidetector computed tomography as reference

    International Nuclear Information System (INIS)

    Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Kuribayashi, Sachio; Abe, Takayuki; Ogawa, Kenji

    2013-01-01

    To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA -950 ) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P -950 . The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA -950 . (orig.)

  2. Post-Installation evaluation of the neutron radiography facility of ITU TRIGA Mark-II Reactor

    International Nuclear Information System (INIS)

    Yavuz, H.; Durmayaz, A.

    2008-01-01

    Results of the experiments for determining the characteristics of the previously described neutron radiography facility designed and built in the Istanbul Technical University are presented. The thermal and total neutron fluxes and the gamma exposure rates have been measured inside, at the exit of the neutron beam collimator, and at its surroundings. The ratio of neutron flux to gamma exposure rate at maximum power has been determined. The results have been compared to those measured in the absence of the collimator. The neutron fluxes have been determined by using the foil activation method with gold foils enclosed in cadmium capsules. The gamma exposure rates have been measured by using Li 7 F- CTLD 700 thermoluminescent dosemeters. (authors)

  3. Fail-safe neutron shutter used for thermal neutron radiography

    International Nuclear Information System (INIS)

    Sachs, R.D.; Morris, R.A.

    1976-11-01

    A fail-safe, reliable, easy-to-use neutron shutter was designed, built, and put into operation at the Omega West Reactor, Los Alamos Scientific Laboratory. The neutron shutter will be used primarily to perform thermal neutron radiography, but is also available for a highly collimated source of thermal neutrons [neutron flux = 3.876 x 10 6 (neutrons)/(cm 2 .s)]. Neutron collimator sizes of either 10.16 by 10.16 cm or 10.16 by 30.48 cm are available

  4. Recent advances in fast neutron radiography for cargo inspection

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Tickner, J.R.

    2007-01-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance

  5. Introduction to industrial radiography

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    For the first topic in this book, more on introduction to nondestructive testing, also a little bit on another technique such as magnetic testing, liquid penetrated, ultrasonic testing and others. This book mentions more on radiographic testing and for that, more details on this topic such as history, definition and devices that use in this technique. This radiography testing firstly started with the discovering of x-ray by Wilhelm Roentgen (1895). So, on 1913, David Coolidge successfully invented and developed x-ray tube that could made x-ray more intensified and produced highly penetration forces. Radiography in Malaysia firstly started two years after the discovery made by Wilhelm Roentgen when one hospital here used the x-ray machine for medical purposes. Besides using x-ray, radiography also used gamma rays, and for these purpose, they used Co-60 and Ir-192. Now, more company based on NDT established to provide a service on inspection pipe and others. For filled these requirement, radiographer must take an exam to make them expert and trained well to work in this field. There is no advantage using this technique or other technique. So that's why this book was published to make people understand what is radiographic testing truly.

  6. Problems associated with veterinary dental radiography

    International Nuclear Information System (INIS)

    Eisner, E.R.

    1990-01-01

    Veterinarians have been radiographing animal skulls for many years, but sophisticated dentistry was not widely used until the 1970s. Elevated awareness of veterinary dental techniques has led to the need for producing accurate radiographic images of the teeth and periodontal structures. Many problems arise for the clinician who treats small animals who has, before this time, radiographed the skull of dogs and cats solely for the purpose of assessing neoplastic, infectious, or traumatic disease of the mandible, maxilla, or calvarium and now desires to perform dental radiography. This chapter will describe the advantages and disadvantages of some of the more common types of radiographic equipment and supplies, discuss extraoral and intraoral radiographic positioning and technique, identify anatomic landmarks and diagnostic features of intraoral radiography, and offer suggestions concerning the art of using dental radiography in veterinary practice

  7. INDUSTRIAL RADIOGRAPHY STUDENT GUIDE AND LABORATORY EXERCISES.

    Science.gov (United States)

    Bureau of Adult, Vocational, and Technical Education (DHEW/OE), Washington, DC. Div. of Vocational and Technical Education.

    THIS INSTRUCTOR'S GUIDE TO AN 80-HOUR COURSE IN INDUSTRIAL RADIOGRAPHY IS COORDINATED WITH LESSONS IN THE STUDENT GUIDE AND LABORATORY EXERCISES AND IS BASED ON MATERIAL IN THE COURSE MANUAL, INDUSTRIAL RADIOGRAPHY. THE COURSE IS INTENDED TO TRAIN HIGH SCHOOL GRADUATES AS BEGINNING RADIOGRAPHERS WHO ARE EXPECTED TO BE ABLE TO EXTEND THEIR…

  8. Development of cosmic-ray radiography with nuclear emulsion and its applications

    International Nuclear Information System (INIS)

    Morishima, Kunihiro

    2017-01-01

    We are developing cosmic-ray radiography with nuclear emulsion. Cosmic-ray radiography is non-destructive inspection technology to take image of inner structure of gigantic objects (nuclear reactor, pyramids, volcanoes and so on). We conducted cosmic-ray radiography of Fukushima Daiichi Nuclear Power Plant from 2014 to 2015 and are conducting cosmic-ray radiography of Pyramids at Egypt from 2015. In this paper, technical details and latest results are presented. (author)

  9. Predictors of Post-Operative Pain Relief in Patients with Chronic Pancreatitis Undergoing the Frey or Whipple Procedure.

    Science.gov (United States)

    Sinha, Amitasha; Patel, Yuval A; Cruise, Michael; Matsukuma, Karen; Zaheer, Atif; Afghani, Elham; Yadav, Dhiraj; Makary, Martin A; Hirose, Kenzo; Andersen, Dana K; Singh, Vikesh K

    2016-04-01

    Post-operative pain relief in chronic pancreatitis (CP) is variable. Our objective was to determine clinical imaging or histopathologic predictor(s) of post-operative pain relief in CP patients undergoing the Whipple or Frey procedure. All patients who underwent a Whipple (n = 30) or Frey procedure (n = 30) for painful CP between January 2003 and September 2013 were evaluated. A toxic etiology was defined as a history of alcohol use and/or smoking. The pre-operative abdominal CT was evaluated for calcification(s) and main pancreatic duct (MPD) dilation (≥5 mm). The post-operative histopathology was evaluated for severe fibrosis. Clinical imaging and histopathologic features were evaluated as predictors of post-operative pain relief using univariable and multivariable regression analysis. A total of 60 patients (age 51.6 years, 53% males) were included in our study, of whom 42 (70%) reported post-operative pain relief over a mean follow-up of 1.1 years. There were 37 (62%) patients with toxic etiology, 36 (60%) each with calcification(s) and MPD dilation. A toxic etiology, calcifications, and severe fibrosis were associated with post-operative pain relief on univariable analysis (all p Whipple or Frey procedure.

  10. The effect of dietary fatty acids on post-operative inflammatory response in a porcine model

    DEFF Research Database (Denmark)

    Langerhuus, Sine Nygaard; Jensen, Karin Hjelholt; Tønnesen, Else Kirstine

    2012-01-01

    ), sunflower oil (SO, n 28), or animal fat (AF, n 28) was evaluated with respect to post-operative responses in inflammatory markers in a porcine model on aortic vascular prosthetic graft infection. In the early post-operative period (0 necrosis factor...

  11. Medical radiography with fast neutrons

    International Nuclear Information System (INIS)

    Duehmke, E.

    1980-01-01

    Neutron radiography is important in medicine for two reasons. On the one hand, macroradiographical findings are different from X-ray findings, i.e. new information may be gained on the morphology of humans and animals. On the other hand, there is a direct practical application in the radiotherapy of malignant tumours if one considers the assessment of the growth of malignant processes. Fast neutrons are required for neutron radiographies of biological objects with a diameter of more than 2 cm. In addition sensitive, two-dimensional detectors must be used which are selective for fast neutrons. The book describes the optimisation and sensitisation of a detector using the example of cellulose nitrate foil for fast reactor neutrons. Images of human spinal chords with tumours proved by pathological and anatomical examinations give a better picture of the dimensions of the tumour than comparative X-ray pictures. For examinations of living patients, neutron radiography should be applied only in those tumour-bearing parts of the bodies in which radiation treatment is required for therapeutical purposes anyway. (orig./MG) [de

  12. Post-Irradiation Non-Destructive Analyses of the AFIP-7 Experiment

    Science.gov (United States)

    Williams, W. J.; Robinson, A. B.; Rabin, B. H.

    2017-12-01

    This article reports the results and interpretation of post-irradiation non-destructive examinations performed on four curved full-size fuel plates that comprise the AFIP-7 experiment. These fuel plates, having a U-10 wt.%Mo monolithic design, were irradiated under moderate operating conditions in the Advanced Test Reactor to assess fuel performance for geometries that are prototypic of research reactor fuel assemblies. Non-destructive examinations include visual examination, neutron radiography, profilometry, and precision gamma scanning. This article evaluates the qualitative and quantitative data taken for each plate, compares corresponding data sets, and presents the results of swelling analyses. These characterization results demonstrate that the fuel meets established irradiation performance requirements for mechanical integrity, geometric stability, and stable and predictable behavior.

  13. A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization

    International Nuclear Information System (INIS)

    Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco; Acchiappati, Domenico

    2011-01-01

    Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

  14. Post-operative pain following coblation or monopolar electrocautery tonsillectomy in children: a prospective, single-blinded, randomised comparison.

    Science.gov (United States)

    Parker, N P; Walner, D L

    2011-10-01

    To compare post-operative pain following tonsillectomy by either coblation or monopolar electrocautery in children. A parallel-designed, prospective, single-blinded, randomised trial. Ambulatory surgical facility. Eighty otherwise healthy paediatric patients undergoing coblation or electrocautery tonsillectomy by a fellowship-trained paediatric otolaryngologist. (i) The number of post-operative days with severe pain based on subjective qualification by the caretaker, (ii) post-operative days with pain rated ≥ 5 on a scale of 1-10, (iii) post-operative days requiring oral paracetamol/acetaminophen with codeine solution and (iv) post-operative days until resumption of a regular diet were assessed and recorded daily using a post-operative pain survey as a form of daily diary that was returned at the 2-week follow-up visit. Patients were consecutively enrolled into two groups of 40 patients. Average ages were 5.2 years for coblation tonsillectomy and 6.0 years for electrocautery tonsillectomy. The average number of post-operative days with severe pain was 4.2 for coblation and 5.9 for electrocautery (P = 0.006), days rating pain ≥ 5 were 3.6 for coblation and 4.8 for electrocautery (P = 0.037), days of codeine use were 2.5 for coblation and 2.9 for electrocautery (P = 0.324), and days until resumption of a regular diet were 5.2 for coblation and 6.2 for electrocautery (0.329). Coblation tonsillectomy may reduce post-operative pain and the time until resumption of a regular diet compared to electrocautery tonsillectomy. © 2011 Blackwell Publishing Ltd.

  15. Nutritional status, nutrition practices and post-operative complications in patients with gastrointestinal cancer.

    Science.gov (United States)

    Garth, A K; Newsome, C M; Simmance, N; Crowe, T C

    2010-08-01

    Malnutrition and its associated complications are a considerable issue for surgical patients with upper gastrointestinal and colorectal cancer. The present study aimed to determine whether specific perioperative nutritional practices and protocols are associated with improved patient outcomes in this group. Patients admitted for elective upper gastrointestinal or colorectal cancer surgery (n = 95) over a 19-month period underwent a medical history audit assessing weight changes, nutritional intake, biochemistry, post-operative complications and length of stay. A subset of patients (n = 25) underwent nutritional assessment by subjective global assessment prior to surgery in addition to assessment of post-operative medical outcomes, nutritional intake and timing of dietetic intervention. Mean (SD) length of stay for patients was 14.0 (12.2) days, with complication rates at 35%. Length of stay was significantly longer in patients who experienced significant preoperative weight loss compared to those who did not [17.0 (15.8) days versus 10.0 (6.8) days, respectively; P nutritional assessment, 32% were classified as mild-moderately malnourished and 16% severely malnourished. Malnourished patients were hospitalised twice as long as well-nourished patients [15.8 (12.8) days versus 7.6 (3.5) days; P nutrition post surgery was a factor in post-operative outcomes, with a positive correlation with length of stay (r = 0.493; P cancer. Poor nutritional status coupled with delayed and inadequate post-operative nutrition practices are associated with worse clinical outcomes.

  16. Radiography and bone scintigraphy in bone marrow transplant multiple myeloma patients

    International Nuclear Information System (INIS)

    Aagren, B.; Aspelin, P.

    1997-01-01

    Purpose: To compare conventional radiography and bone scintigraphy in relation to clinical outcome in bone marrow transplant multiple myeloma patients. Material and Methods: A total of 70 radiographies and 70 bone scintigraphies were compared in 35 patients. Results: The skull, the extremities, the iliac and public bones were better assessed with radiography. For new vertebral lesions and for lesions in the ribs and sternum, bone scintigraphy proved superior. For the sacrum, the methods were equal. When bone scintigraphy was used as a complement to radiography, 4% more pathological sites were found. No patient had both a normal radiography and a pathological bone scintigraphy, but 5 patients had both a normal bone scintigraphy and a pathological radiography. The results of the radiological examinations did not always correlate with the clinician's grading of the patient's disease. The radiological examinations had no prognostic value for the 7 patients examined on several occasions. Conclusion: The ability of conventional radiography and bone scintigraphy to disclose myeloma lesions varies, depending on location and size of the lesions. Radiography should remain the primary examination modality also for bone marrow transplant multiple myeloma patients. Bone scintigraphy can severe as a complement for investigating unexplained pain, e.g. caused by lesions in vertebrae or ribs. (orig.)

  17. POST-RELIGION: TRADITIONALISTS’ ANALYSIS

    Directory of Open Access Journals (Sweden)

    Kirill M. Tovbin

    2013-12-01

    Full Text Available Aim of the study is to describe the phenomenon of post-religion as a specific spiritual sphere of the Post-modernity. Methodology. In the introduction analyzed a variety of methodological approaches, opening his inadequacy applied to the spiritual sphere of Post-modernity: «classic» religious studies, religious studies of traditional spiritual movements and the post-modern religious studies, partly produced Traditionalist school, could - according to the author's hypothesis - become a methodological basis for the most complete analysis of post-religion. Scientific novelty. In the main part of the article crystallized the authorized concept of post-religion, its relation with traditional and religious spiritual realms. Post-religion is positioned as the top of secularism enshrined in the departure from the straight and aggressive secularism of the Modernity, but without recourse to Tradition. Post-religion a simulation spirituality, skillfully imitating the outer areas of traditional spirituality and creates a planar religiosity, radically preventing attached to the vertical line of Traditions. In this regard, are the main artificially selected parameters of post-religion: deconstruction, splitting, virtualization, and collage. Deconstruction is a transformation of spirituality in semiotic set for egocentric selectivity of modern believer. Post-religion’s splitting is deprivation of spirituality center, destruction of sacral Center and the transformation of spirituality in the plane on which the intellectual and sensual wandering post-believer from one semiotic island to another. Virtualization is a displacement field of spiritual tension in a completely virtual area, isolated from the natural conditions of existence and created as his replacement, network discussion sites and galleries. Collage is an arbitrary combination of different semiotic pieces of Tradition with the aim of creating a believable picture of tradition; it is collage leads

  18. Digital image intensifier radiography. One year's experience with a Polytron system

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.; Georgi, M.

    1989-01-01

    Since January 1988, digital image intensifier radiography has been used in the Clinic in Mannheim for DSA examinations and also in place of conventional screen/film examinations. Measurements have shown that compared with 100 mm and film/screen formats, digital radiography has poorer spatial resolution, but improved contrast resolution. The most common use of digital radiography was for examinations of the gastrointestinal tract. Using the demonstration of the mucosal fine relief pattern as a criterion of image quality, digital image intensifier radiography was able to achieve this satisfactorily. Comparison with film/screen examinations showed no loss of diagnostic information. Advantages of image intensifier radiography are reduced radiation dose, the possibility of postprocessing and economy. On the basis of 399 examinations, digital image intensifier radiography is now firmly established as part of the daily routine of the Mannheim Clinic. (orig.) [de

  19. Comparison of Radiography, Laser Fluorescence, and Visual Examination in Diagnosing Incipient OcclusalCaries of Permanent First Molars

    Directory of Open Access Journals (Sweden)

    Zahra Bahrololoomi

    2015-10-01

    Full Text Available Objectives: Early diagnosis of incipient and non cavitated carious lesions is crucial for performing preventive treatments. The aim of this study was to compare the effi- ciency of three diagnostic methods of bite-wing radiography, DIAGNOdent, and visu- al examination in diagnosing the incipient occlusal caries of permanent first molars.Materials and Methods:  In this diagnostic cross-sectional study, 109 premanent first molar teeth of 31 patients aged 7-13 years were examined visually by bite-wing radi- ograghy, and DIAGNOdent. Scoring of visual and radiography examinations were based on the Ekstrand classification. Visual examination after pit and fissure opening was used as the gold standard. ROC curve (Receiver Operating Characteristics was used to define the best cut-off point for DIAGNodent compareing with gold standard and inter-examiner reproductibility of visual, radiography were assessed using Kappa test and ICC (Intraclass Correlation wase used for DIAGNOdent values.Results: The sensitivity of detecting caries that had extended into the enamel was 81.4%, 86.3%, and 81.4% for visual examination, DIAGNOdent, and radiography, respectively. Moreover, the specificity was 100%, 71.4%, and 100% for visual obser- vation, DIAGNOdent, and radiography, respectively in the enamel. The Kappa index for inter-examiner correlation was 0.7 and 0.8 for visual examination and radiog- raphy, respectively. The ICC (Intraclass Correlation was 0.98 for the values read by DIAGNOdent.Conclusion: Visual examination is rendered as the first choice in the diagnosis of in- cipient caries. In suspicious cases, radiography and laser DIAGNOdent can be used as adjunct procedures.

  20. Ambulating radiography

    International Nuclear Information System (INIS)

    Magnusson, K.

    1989-01-01

    Strong gamme or X-ray sources are utilized for non-destructive testing of i.e. bridges. The activities involve certain risks of accident that might lead to serious injuries caused by radiation. The National Institute of Radiation Protection has during the laste decade greatly yhe inspection rate in this area. It has today made controls of most enterprieses running ambulating radiography. (O.S.)

  1. Neutron emission in neutral beam heated KSTAR plasmas and its application to neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Jong-Gu, E-mail: jgkwak@nfri.re.kr; Kim, H.S.; Cheon, M.S.; Oh, S.T.; Lee, Y.S.; Terzolo, L.

    2016-11-01

    Highlights: • We measured the neutron emission from KSTAR plasmas quantitatively. • We confirmed that neutron emission is coming from neutral beam-plasma interactions. • The feasibility study shows that the fast neutron from KSTAR could be used for fast neutron radiography. - Abstract: The main mission of Korea Superconducting Tokamak Advanced Research (KSTAR) program is exploring the physics and technologies of high performance steady state Tokamak operation that are essential for ITER and fusion reactor. Since the successful first operation in 2008, the plasma performance is enhanced and duration of H-mode is extended to around 50 s which corresponds to a few times of current diffusion time and surpassing the current conventional Tokamak operation. In addition to long-pulse operation, the operational boundary of the H-mode discharge is further extended over MHD no-wall limit(β{sub N} ∼ 4) transiently and higher stored energy region is obtained by increased total heating power (∼6 MW) and plasma current (I{sub p} up to 1 MA for ∼10 s). Heating system consists of various mixtures (NB, ECH, LHCD, ICRF) but the major horse heating resource is the neutral beam(NB) of 100 keV with 4.5 MW and most of experiments are conducted with NB. So there is a lot of production of fast neutrons coming from via D(d,n){sup 3}He reaction and it is found that most of neutrons are coming from deuterium beam plasma interaction. Nominal neutron yield and the area of beam port is about 10{sup 13}–10{sup 14}/s and 1 m{sup 2} at the closest access position of the sample respectively and neutron emission could be modulated for application to the neutron radiography by varying NB power. This work reports on the results of quantitative analysis of neutron emission measurements and results are discussed in terms of beam-plasma interaction and plasma confinement. It also includes the feasibility study of neutron radiography using KSTAR.

  2. High speed motion neutron radiography of two-phase flow

    International Nuclear Information System (INIS)

    Robinson, A.H.; Wang, S.L.

    1983-01-01

    Current research in the area of two-phase flow utilizes a wide variety of sensing devices, but some limitations exist on the information which can be obtained. Neutron radiography is a feasible alternative to ''see'' the two-phase flow. A system to perform neutron radiographic analysis of dynamic events which occur on the order of several milliseconds has been developed at Oregon State University. Two different methods have been used to radiograph the simulated two-phase flow. These are pulsed, or ''flash'' radiography, and high speed movie neutron radiography. The pulsed method serves as a ''snap-shot'' with an exposure time ranging from 10 to 20 milliseconds. In high speed movie radiography, a scintillator is used to convert neutrons into light which is enhanced by an optical intensifier and then photographed by a high speed camera. Both types of radiography utilize the pulsing capability of the OSU TRIGA reactor. The principle difficulty with this type of neutron radiography is the fogging of the image due to the large amount of scattering in the water. This difficulty can be overcome by using thin regions for the two-phase flow or using heavy water instead of light water. The results obtained in this paper demonstrate the feasibility of using neutron radiography to obtain data in two-phase flow situations. Both movies and flash radiographs have been obtained of air bubbles in water and boiling from a heater element. The neutron radiographs of the boiling element show both nucleate boiling and film boiling. (Auth.)

  3. [Post-marketing clinical study of traditional Chinese medicine--lessons learned from comprehensive evaluation of Fufang Zaoren capsule].

    Science.gov (United States)

    Qing, Shan; Gao, Lin; Zhang, Li; Jia, Jian-Ping; Liu, Xin-Min; Ji, Shao-Liang; Yang, Xiao-Hui

    2013-11-01

    By comprehensive review and analysis of post-marketing clinical research on the efficacy and safety,we concluded that Fufang Zaoren capsule has certain therapeutic effects for insomnia, although current clinical research design needs improving. The post-marketing clinical studies also showed that it causes several adverse reactions at the recommended doses, such as chills, fever, dizziness, nausea, shortness of breath, chest tightness and palpitations, whereas high doses of Fufang Zaoren capsule can cause delayed extrapyramidal symptoms. Health Canada government website also prompted the L-tetrahydropalmatine in Fufang Zaoren capsule caused liver damage in pregnant women. The authors summarized the risk points, factors and risk control in the clinical use of Fufang Zaoren capsule and also present their perspective on the research status, existing problems and corresponding countermeasures in the post-marketing clinical re-evaluation of traditional Chinese medicine.

  4. Development of techniques for furthering the use of isotope radiography

    International Nuclear Information System (INIS)

    Wamorkar, R.R.; Singh, G.; Kalurkar, A.R.; Jagasia, N.S.; Malhotra, H.K.

    1977-01-01

    Isotope radiography techniques in the non-conventional applications such as : (a) hot radiography - a method for examination of radioactive materials, and (b) thin section radiography for inspection of biological specimen and non-metallic specimen are described. Also, a process used for the reproduction of gamma-graphs of welds and castings has been discussed in detail. (author)

  5. Fast neutron (14.5 MeV) radiography: a comparative study

    International Nuclear Information System (INIS)

    Klann, R.T.

    1996-01-01

    Fast neutron (14.5 MeV) radiography is a type of non-destructive analysis tool that offers its own benefits and drawbacks. Because cross-sections vary with energy, a different range of materials can be examined with fast neutrons than can be studied with thermal neutrons, epithermal neutrons, or x-rays. This paper details these differences through a comparative study of fast neutron radiography to the other types of radiography available. The most obvious difference among the different types of radiography is in the penetrability of the sources. Fast neutrons can probe much deeper and can therefore obtain details of the internals of thick objects. Good images have been obtained through as much as 15 cm of steel, 10 cm of water, and 15 cm of borated polyethylene. In addition, some objects were identifiable through as much as 25 cm of water or 30 cm of borated polyethylene. The most notable benefit of fast neutron radiography is in the types of materials that can be tested. Fast neutron radiography can view through materials that simply cannot be viewed by X rays, thermal neutrons, or epithermal neutrons due to the high cross-sections or linear attenuation coefficients involved. Cadmium was totally transparent to the fast neutron source. Fast neutron radiography is not without drawbacks. The most pronounced drawback has been in the quality of radiograph produced. The image resolution is only about 0.8 mm for a 1.25 cm thick object, whereas, other forms of radiography have much better resolution

  6. Use of radiography in archaeology

    International Nuclear Information System (INIS)

    Chetin, M.; Ekinci, Sh.; Aksu, M.

    2014-01-01

    Full text : Radiography is a versatile technique with many applications to archaeological and art historical artefacts. It can be used to assess the condition of objects before conservation treatment, to gain insight into materials used and methods of construction and to reveal the secrets of the embalmers art, hidden within mummified remains. X-ray radiography is an invaluable investigative technique that is non-destructive, quick and cost effective. The study described below covers the investigations of the archaeological artefacts in order to determine their corrosion conditions and production histories which are important for restoration, conservation, replica, dating and inventory works

  7. Assessment of 99Tcm-ethylenedicysteine diuretic renography in pre-and post-operative pediatric congenital hydronephrosis

    International Nuclear Information System (INIS)

    Ye Zhiyi; Wang Hui; Li Jianing; Fu Hongliang; Wu Jingchuan

    2010-01-01

    Objective: To investigate the clinical value of 99 Tc m -ethylenedicysteine (EC) diuretic renography (DR) in pre-and post-operative pediatric congenital hydronephrosis. Methods: The DR with injection of Furosemide at 15 min of forty children with hydronephrosis was retrospectively studied. The preoperative renal blood perfusion rate (BPR), effective renal plasma flow (ERPF), grade of hydronephrosis,renogram and renal dynamic imaging of pre- and post-operative kidneys were compared. The t-test and Mann-Whitney test were used for data analysis. Results: (1) Of 40 pathological kidneys, the BPR increased 5.99% (t=-5.13, P<0.01) from pre-operative to post-operative: (34.05 ± 11.07)% to (40.04 ± 8.56)%. The ERPF increased 12.48 ml/min (t=-4.35, P<0.01) from pre-operative to post-operative: (57.81 ± 34.32) ml/min to (70.29 ± 5.37) ml/min. (2) The grade of hydronephrosis of 40 pathological kidneys improved significantly(Z=-2.64, P<0.01) with the mean sum of ranks of 47.21 pre-operatively to 33.79 post-operatively.(3) As the hydronephrosis worsened, the collecting system became bigger, the renal parenchyma became thinner, the extent of intrarenal parenchymal photopenia became larger and the response to diuretic challenge in pathological kidneys decreased or became totally irresponsive. (4)Thirty-seven cases of obstruction at ureteropelvic junction (UPJO) and 3 cases at ureterovesical junction (UVJO) were diagnosed by DR, which were all confirmed by surgery. Conclusions: DR is a reliable method to evaluate pediatric congenital hydronephrosis.It can accurately reflect the grade and (or) severity of the disease, guide therapy and assess the therapeutic success of operation. (authors)

  8. Music Therapy for Post Operative Cardiac Patients

    DEFF Research Database (Denmark)

    Schou, Karin

    of participants' self-reporting of anxiety, pain and mood before and after surgery. Data were also collected on length of hospital stay, participants' satisfaction with the hospitalisation, and on participants' intake of analgesic medication. Participants self-reported through questionnaires on the importance...... and after treatment. Conclusion The sample was relatively small reducing the statistical power. However, the results tend to support findings from previous studies that have involved interventions with post-operative patients. Future research should investigate whether GRM would prove beneficial for wider...

  9. Interprofessional working in diagnostic radiography

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.; Day, Jane

    2014-01-01

    This paper considers interprofessional working within one diagnostic imaging department. The literature is still divided about the long-term impact of interprofessional learning in pre-registration health and social care education, and its impact on the quality of care provided. When reading the literature about interprofessional working the main topics considered by other authors are team working, communication between professionals, stereotyping and tribalism. The results presented are from an ethnographic study in one department with participant observation and semi-structured interviews. The three main aspects discussed in this paper are; tribalism and culture within the diagnostic radiography profession, communication between different professional groups, and a lack of understanding of the roles of other professional groups. It was evident from the results of this study that tribalism and culture, and a lack of understanding were significant barriers to interprofessional working. It was felt by the authors that pre-registration and post-registration interprofessional education could be significant in changing the culture of the NHS in the future as more professionals learn from and about one another

  10. Proton Radiography (pRad)

    Data.gov (United States)

    Federal Laboratory Consortium — The proton radiography project has used 800 MeV protons provided by the LANSCE accelerator facility at LANL, to diagnose more than 300 dynamic experiments in support...

  11. Long-term biatrial recordings in post-operative atrial fibrillation.

    Science.gov (United States)

    Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F

    2010-01-01

    Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.

  12. Quality comparison of direct digital panoramic radiography and computed radiography panoramic

    Directory of Open Access Journals (Sweden)

    Dariush Goodarzipour

    2013-09-01

    Full Text Available BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels. The first category is defined as computed radiography (CR or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR. Both of these technologies have their own advantages and disadvantages. One of the most important fields in comparison of these systems is their resultant image quality. The purpose of this study was to compare the subjective image quality of DDR and CR digital panoramic system, and to assess the overall density and contrast of their images. METHODS: 200 patients were randomly allocated to two digital systems: Promax [central control digital (CCD] and XC [photostimulable phosphor plates (PSP]. Image quality was evaluated in six regions on a 3-point scale by three oral and maxillofacial radiologists independently. In addition, observers assessed overall density and contrast of each image on a 3-point scale. RESULTS: Using chi-square test, no statistically significant differences were found (P >0.05 in subjective image quality of anatomic structures between the two radiographic systems. But DDR system outperformed CR system in overall density and contrast of the image. P values for both overall density and contrast of the images was less than 0.001. CONCLUSIONS: The subjective image quality of CR and DDR panoramic systems in specified anatomic regions were found statistically comparable in this study. In overall density and contrast of the radiographs, DDR system proved better than CR system.

  13. Radiography of the chest and upper airway

    International Nuclear Information System (INIS)

    Sharko, G.A.; Wilmot, D.M.

    1987-01-01

    The techniques of radiography of the chest in all pediatric-age groups differ only slightly from those used in adult radiography. The technologist's principal challenge, however, relates to optimum handling of the patient with respect to positioning and radiation protection. The hints provided in this chapter should permit the conscientious radiographer to obtain high quality radiographs on all pediatric patients

  14. Radiological protection in equine radiography and radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yoxall, A.T.

    1977-10-01

    The principles of radiological protection are summarised and consideration is then given to problems, which may confront the equine practitioner, in the fulfillment of these principles during diagnostic radiography of the limbs, head, and spine of the horse. The place of anaesthesia in such procedures is discussed and the special problems associated with therapeutic radiography of the horse are considered.

  15. Fuji computed radiography (FCR) for the diagnosis of spinal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Yoshichika; Waga, Shiro; Kojima, Tadashi

    1987-04-01

    Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal posterior osteophytes and grafted bone, even when the patients are immobilized in a Halo apparatus. In myelography, the pictures are also clearer; we can see how the root or roots are compressed, how the dura and cord are involved in patients with cervical disc disease, and even the very narrow space between the cord and an intradural tumor. FCR is thus very useful in observing spinal disorders, either in plain films or myelography.

  16. Fuji computed radiography (FCR) for the diagnosis of spinal disorders

    International Nuclear Information System (INIS)

    Kubo, Yoshichika; Waga, Shiro; Kojima, Tadashi

    1987-01-01

    Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal posterior osteophytes and grafted bone, even when the patients are immobilized in a Halo apparatus. In myelography, the pictures are also clearer; we can see how the root or roots are compressed, how the dura and cord are involved in patients with cervical disc disease, and even the very narrow space between the cord and an intradural tumor. FCR is thus very useful in observing spinal disorders, either in plain films or myelography. (author)

  17. Evaluation of a Noise Reduction Procedure for Chest Radiography

    Science.gov (United States)

    Fukui, Ryohei; Ishii, Rie; Kodani, Kazuhiko; Kanasaki, Yoshiko; Suyama, Hisashi; Watanabe, Masanari; Nakamoto, Masaki; Fukuoka, Yasushi

    2013-01-01

    Background The aim of this study was to evaluate the usefulness of noise reduction procedure (NRP), a function in the new image processing for chest radiography. Methods A CXDI-50G Portable Digital Radiography System (Canon) was used for X-ray detection. Image noise was analyzed with a noise power spectrum (NPS) and a burger phantom was used for evaluation of density resolution. The usefulness of NRP was evaluated by chest phantom images and clinical chest radiography. We employed the Bureau of Radiological Health Method for scoring chest images while carrying out our observations. Results NPS through the use of NRP was improved compared with conventional image processing (CIP). The results in image quality showed high-density resolution through the use of NRP, so that chest radiography examination can be performed with a low dose of radiation. Scores were significantly higher than for CIP. Conclusion In this study, use of NRP led to a high evaluation in these so we are able to confirm the usefulness of NRP for clinical chest radiography. PMID:24574577

  18. Assessment of post-operative pain management among acutely and electively admitted patients - a Swedish ward perspective.

    Science.gov (United States)

    Magidy, Mahnaz; Warrén-Stomberg, Margareta; Bjerså, Kristofer

    2016-04-01

    Swedish health care is regulated to involve the patient in every intervention process. In the area of post-operative pain, it is therefore important to evaluate patient experience of the quality of pain management. Previous research has focused on mapping this area but not on comparing experiences between acutely and electively admitted patients. Hence, the aim of this study was to investigate the experiences of post-operative pain management quality among acutely and electively admitted patients at a Swedish surgical department performing soft-tissue surgery. A survey study design was used as a method based on a multidimensional instrument to assess post-operative pain management: Strategic and Clinical Quality Indicators in Postoperative Pain Management (SCQIPP). Consecutive patients at all wards of a university hospital's surgical department were included. Data collection was performed at hospital discharge. In total, 160 patients participated, of whom 40 patients were acutely admitted. A significant difference between acutely and electively admitted patients was observed in the SCQIPP area of environment, whereas acute patients rated the post-operative pain management quality lower compared with those who were electively admitted. There may be a need for improvement in the areas of post-operative pain management in Sweden, both specifically and generally. There may also be a difference in the experience of post-operative pain quality between acutely and electively admitted patients in this study, specifically in the area of environment. In addition, low levels of the perceived quality of post-operative pain management among the patients were consistent, but satisfaction with analgesic treatment was rated as good. © 2015 John Wiley & Sons, Ltd.

  19. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess; Thomas L. Maddock; Margaret A. Marshall; Leland M. Montierth

    2011-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has been evaluated as an acceptable benchmark experiment. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has not been evaluated as it is very similar to the evaluated core configuration. The benchmark eigenvalue is 1.0012 ± 0.0029. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  20. Fresh-Core Reload of the Neutron Radiography (NRAD) Reactor with Uranium(20)-Erbium-Zirconium-Hydride Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Bess, John D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Maddock, Thomas L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Marshall, Margaret A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Montierth, Leland M. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Ning [Idaho National Lab. (INL), Idaho Falls, ID (United States); Phillips, Ann Marie [Idaho National Lab. (INL), Idaho Falls, ID (United States); Schreck, Kenneth A. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Briggs, J. Blair [Idaho National Lab. (INL), Idaho Falls, ID (United States); Woolstenhulme, Eric W. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bolin, John M. [General Atomics, San Diego, CA (United States); Veca, Anthony [General Atomics, San Diego, CA (United States); McKnight, Richard D. [Argonne National Lab. (ANL), Argonne, IL (United States); Lell, Richard M. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA® (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The 60-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has been evaluated as an acceptable benchmark experiment. The initial critical configuration developed during the fuel loading process, which contains only 56 fuel elements, has not been evaluated as it is very similar to the evaluated core configuration. The benchmark eigenvalue is 1.0012 ± 0.0029. Calculated eigenvalues differ significantly (~±1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.