WorldWideScience

Sample records for traditional off-pump coronary

  1. A comparison of hybrid coronary revascularization and off-pump coronary revascularization.

    Science.gov (United States)

    Umakanthan, Ramanan; Leacche, Marzia; Gallion, Anna H; Byrne, John G

    2013-04-01

    Minimally invasive approaches to treat vascular disease have been accruing significant popularity over the last several decades. Due to progressive advances in technology, a variety of techniques are being now utilized in the field of cardiovascular surgery. The objectives of minimally invasive techniques are to curtail operative trauma and minimize perioperative morbidity without decreasing the quality of the treatment. The standard surgical approach for the treatment of coronary artery disease has traditionally been coronary artery bypass grafting surgery via median sternotomy. Off-pump coronary artery bypass grafting surgery offers a less invasive alternative and enables coronary revascularization to be performed without cardiopulmonary bypass. Hybrid coronary revascularization offers an even less invasive option in which minimally invasive direct coronary artery bypass can be combined with percutaneous coronary intervention. In this article, the authors review a recent publication comparing hybrid coronary revascularization and off-pump coronary artery bypass grafting surgery.

  2. Off-Pump Versus On-Pump Coronary Artery Bypass Grafting

    DEFF Research Database (Denmark)

    Møller, Christian H; Steinbrüchel, Daniel A

    2014-01-01

    Coronary artery bypass grafting (CABG) remains the preferred treatment in patients with complex coronary artery disease. However, whether the procedure should be performed with or without the use of cardiopulmonary bypass, referred to as off-pump and on-pump CABG, is still up for debate....... Intuitively, avoidance of cardiopulmonary bypass seems beneficial as the systemic inflammatory response from extracorporeal circulation is omitted, but no single randomized trial has been able to prove off-pump CABG superior to on-pump CABG as regards the hard outcomes death, stroke or myocardial infarction....... In contrast, off-pump CABG is technically more challenging and may be associated with increased risk of incomplete revascularization. The purpose of the review is to summarize the current literature comparing outcomes of off-pump versus on-pump coronary artery bypass surgery....

  3. Early outcome of off-pump versus on-pump coronary revascularization

    African Journals Online (AJOL)

    Introduction: The use of coronary artery bypass surgery (CABG) with cardiopulmonary bypass (CPB) or without CPB technique (off-pump) can be associated with different mortality and morbidity and their outcomes remain uncertain. The goal of this study was to evaluate the early outcome of on-pump versus off-pump CABG.

  4. Off-pump versus on-pump coronary artery bypass grafting for ischaemic heart disease

    DEFF Research Database (Denmark)

    Møller, Christian H; Penninga, Luit; Wetterslev, Jørn

    2012-01-01

    Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear.......Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear....

  5. On-pump versus off-pump coronary artery bypass surgery

    DEFF Research Database (Denmark)

    Houlind, Kim Christian

    2013-01-01

    Off pump coronary artery bypass surgery has been purported to be safer than conventional coronary artery bypass surgery performed using cardiopulmonary bypass. This theory was supported by a number of early series, but failed to be confirmed by a number of small, randomized controlled trials...

  6. Off-pump coronary artery bypass surgery in severe left ventricular dysfunction.

    Science.gov (United States)

    Azarfarin, Rasoul; Pourafkari, Leili; Parvizi, Rezayat; Alizadehasl, Azin; Mahmoodian, Roghaiyeh

    2010-02-01

    Our aim was to examine hospital outcomes of coronary artery bypass surgery in patients with and without left ventricular dysfunction, with regard to the surgical technique (off- or on-pump). Between March 2007 and March 2008, 689 consecutive patients underwent isolated first-time coronary artery bypass; 127 had ejection fractions fractions >30% (group 2). Data of preoperative risk profiles and hospital outcomes were collected prospectively. Off-pump operations were performed in 49 (38.6%) patients in group 1 and 196 (34.9%) in group 2. The incidences of infectious, neurologic, and cardiac complications postoperatively were significantly higher in group 1. In multivariate analysis, preoperative ejection fraction operations, but no significant difference in mortality was observed between those undergoing off-pump or conventional surgery in either group. Off-pump surgery helped to limit the increased morbidity rate after coronary bypass in patients with ventricular dysfunction.

  7. Target vessel detection by epicardial ultrasound in off-pump coronary bypass surgery.

    Science.gov (United States)

    Hayakawa, Masato; Asai, Tohru; Kinoshita, Takeshi; Suzuki, Tomoaki; Shiraishi, Shoichiro

    2013-01-01

    The detection of embedded coronary arteries is difficult especially in off-pump coronary bypass surgery. From June 2010, we introduced high-frequency epicardial ultrasound (ECUS) to assess and evaluate embedded arteries during off-pump coronary bypass surgery. Between June 2010 and June 2011, a total of 89 consecutive patients underwent isolated coronary bypass surgery at our institution. The patients consisted of 72 men and 17 women with a mean age of 67.9 years. We routinely use the VeriQC system (MediStim, Oslo, Norway) to detect the target vessels in the operation. The patients were assigned to one of two groups, depending on whether ECUS was used in the operation (n = 10, ECUS group) or not (n = 79, non-ECUS group). We analyzed the impact of introducing the ECUS in terms of operative outcome. All patients underwent revascularization using the off-pump technique without emergent conversion to cardiopulmonary bypass during surgery. The total number of distal anastomoses was 299, and 12 target vessels could not be identified either visually or on palpation. Thus, the frequency of the embedded coronary arteries was 4.01% (12/299 cases). The preoperative profiles of the two groups were not significantly different. Operation time was significantly longer in the ECUS group (P = 0.02). There were no significant differences in postoperative outcome between the two groups. In the present study, in which the target coronary arteries could not be detected either visually or on palpation in 12 (4.01%) of 299 cases, the use of high-frequency ECUS allowed all patients to undergo off-pump coronary bypass surgery without conversion to cardiopulmonary bypass during the operation. High-frequency ECUS is therefore useful in off-pump coronary bypass surgery.

  8. Does Off-Pump Coronary Artery Bypass Grafting Negatively Impact Long-Term Survival and Freedom from Reintervention?

    Directory of Open Access Journals (Sweden)

    Shahzad G. Raja

    2013-01-01

    Full Text Available Recently published evidence has raised concerns about worse late mortality and increasing need for reintervention after off-pump coronary artery bypass grafting. We undertook this study to assess the impact of off-pump coronary artery bypass grafting on survival and freedom from reintervention at 10 years. From January 2002 to December 2002, 307 consecutive patients who had isolated multivessel off-pump coronary artery bypass grafting at our institution were compared to a control group of 397 patients that underwent multivessel on-pump coronary artery bypass grafting during the same period. In addition, univariate and risk-adjusted comparisons between the two groups were performed at 10 years. Kaplan-Meier survival was similar for the two cohorts. After adjusting for clinical covariates, off-pump coronary artery bypass grafting did not emerge as a significant independent predictor of long-term mortality (Hazard Ratio 0.91; 95% Confidence Interval 0.70–1.12, readmission to hospital for cardiac cause (Hazard Ratio 0.96; 95% Confidence Interval 0.78–1.10, or the need for reintervention (Hazard Ratio 0.93; 95% Confidence Interval 0.87–1.05. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting does not adversely impact survival or freedom from reintervention at a 10-year follow-up.

  9. Ischemia monitoring in off-pump coronary artery bypass surgery using intravascular near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Zerkowski Hans-Reinhard

    2006-05-01

    Full Text Available Abstract Background In off-pump coronary artery bypass surgery, manipulations on the beating heart can lead to transient interruptions of myocardial oxygen supply, which can generate an accumulation of oxygen-dependent metabolites in coronary venous blood. The objective of this study was to evaluate the reliability of intravascular near-infrared spectroscopy as a monitoring method to detect possible ischemic events in off-pump coronary artery bypass procedures. Methods In 15 elective patients undergoing off-pump myocardial revascularization, intravascular near-infrared spectroscopic analysis of coronary venous blood was performed. NIR signals were transferred through a fiberoptic catheter for signal emission and collection. For data analysis and processing, a miniature spectrophotometer with multivariate statistical package was used. Signal acquisition and analysis were performed before and after revascularization. Spectroscopic data were compared with hemodynamic parameters, electrocardiogram, transesophageal echocardiography and laboratory findings. Results A conversion to extracorporeal circulation was not necessary. The mean number of grafts per patient was 3.1 ± 0.6. An intraoperative myocardial ischemia was not evident, as indicated by electrocardiogram and transesophageal echocardiography. Continuous spectroscopic analysis showed reproducible absorption spectra of coronary sinus blood. Due to uneventful intraoperative courses, clear ischemia-related changes could be detected in none of the patients. Conclusion Our initial results show that intravascular near-infrared spectroscopy can reliably be used for an online intraoperative ischemia monitoring in off-pump coronary artery bypass surgery. However, the method has to be further evaluated and standardized to determine the role of spectroscopy in off-pump coronary artery bypass surgery.

  10. Graft patency after off-pump coronary artery bypass surgery is inferior even with identical heparinization protocols

    DEFF Research Database (Denmark)

    Houlind, Kim; Fenger-Grøn, Morten; Holme, Susanne J

    2014-01-01

    OBJECTIVE: To determine whether graft patency after on-pump and off-pump coronary artery bypass surgery is similar when performed using the same heparinization protocol. METHODS: In a randomized, controlled, multicenter trial, 900 patients more than 70 years of age received either on-pump or off......-pump coronary artery bypass surgery. Heparin was given to achieve an activated clotting time of 400 seconds before arteriotomy in both groups. After the procedure, protamine sulfate was given to revert the activated clotting time to less than 120 seconds. Coronary angiography was performed 6 months after...

  11. Cognitive outcomes in elderly high-risk patients after off-pump versus conventional coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Jensen, Birte Ostergaard; Hughes, Pia; Rasmussen, Lars S

    2006-01-01

    It has been suggested that the risk of cerebral dysfunction is less with off-pump coronary artery bypass grafting (OPCAB) than with conventional coronary artery bypass grafting (CCAB). However, evidence for this statement is preliminary, and additional insight is needed.......It has been suggested that the risk of cerebral dysfunction is less with off-pump coronary artery bypass grafting (OPCAB) than with conventional coronary artery bypass grafting (CCAB). However, evidence for this statement is preliminary, and additional insight is needed....

  12. Pulmonary hemodynamics and gas exchange in off pump coronary artery bypass grafting.

    Science.gov (United States)

    Vedin, Jenny; Jensen, Ulf; Ericsson, Anders; Samuelsson, Sten; Vaage, Jarle

    2005-10-01

    To investigate the influence of cardiopulmonary bypass on pulmonary hemodynamics and gas exchange. Low risk patients admitted for elective coronary artery bypass grafting were randomized to either on (n=25) or off pump (n=25) surgery. Central hemodynamics, gas exchange, and venous admixture were studied during and up to 20 h after surgery. There was no difference in pulmonary vascular resistance index (P=0.16), right ventricular stroke work index (P>0.2), mean pulmonary artery pressure (P>0.2) or pulmonary capillary wedge pressure (P>0.2) between groups. Soon after surgery there was a tendency towards higher cardiac index (P=0.07) in the off pump group. Arterial oxygen tension (P>0.2), hematocrit (P>0.2), venous admixture (P>0.2), and arterial-venous oxygen content difference (P=0.12) did not differ between groups. This prospective, randomized study showed no difference in pulmonary hemodynamics, pulmonary gas exchange, and venous admixture, in low risk patients undergoing off pump compared to on pump coronary artery bypass surgery.

  13. Chronic Obstructive Pulmonary Disease and Off-Pump Coronary Surgery.

    Science.gov (United States)

    Ovalı, Cengiz; Şahin, Aykut

    2018-05-18

    To determine to what extent chronic obstructive pulmonary disease (COPD) affects mortality and morbidity rates in patients treated with off-pump coronary artery bypass graft (CABG). A total of 321 patients treated with off-pump CABG were included in the present study. Of the 321 patients, 46 patients had COPD and they were designated as Group 1 and the remaining 275 patients did not have COPD and they were considered as Group 2. We compared the data obtained from the patients in both groups. While preoperative spirometry values and arterial blood gas oxygen saturation levels were significantly lower, the partial values of carbon dioxide were higher in Group 1. Likewise, extubation time, the amount of drainage and blood transfusion, inotropic support, prolonged intubation, pulmonary complications, the use of bronchodilators, and steroids were statistically higher in Group 1 when compared with Group 2. Overall, there was no marked difference between the two groups in terms of mortality incidence. We found similar morbidity and mortality rates among the patients with COPD and without COPD when they were treated with off-pump CABG. Therefore, the present results indicate that the presence of COPD is not associated with in-hospital mortality or severe morbidity post-CABG by off-pump approach.

  14. Off-pump coronary artery bypass grafting or percutaneous transluminal coronary angioplasty with stenting for proximal left anterior descending coronary artery disease?

    NARCIS (Netherlands)

    Drenth, Derk Jan

    2005-01-01

    This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis

  15. Off pump vs on pump coronary artery bypass grafting: Perioperative complications and early clinical outcomes

    Directory of Open Access Journals (Sweden)

    Ayman El Naggar

    2012-03-01

    Conclusion: Off pump CABG is safe and associated with good clinical outcome and can be considered alternative to conventional CABG as treatment modality for surgical coronary revascularization but this will need large scale study to establish this technique.

  16. On-Pump Versus Off-Pump Coronary Artery Bypass Surgery in Elderly Patients

    DEFF Research Database (Denmark)

    Houlind, Kim; Kjeldsen, Bo Juul; Madsen, Susanne Nørgaard

    2012-01-01

    BACKGROUND: Conventional coronary artery bypass grafting performed with the use of cardiopulmonary bypass is a well-validated treatment for patients with ischemic heart disease. Off-pump coronary artery bypass grafting (OPCAB) has been suggested to reduce the number of perioperative complications......, especially in elderly patients. METHODS AND RESULTS: In a multicenter, randomized trial, we assigned 900 patients >70 years of age to conventional coronary artery bypass grafting or OPCAB surgery. After 30 days, a blinded end-point committee assessed whether a combined end point of death, stroke...... experiencing the combined end point within 30 days was 10.2% for conventional coronary artery bypass grafting and 10.7% for OPCAB. Implied risk difference of 0.4% (with a 95% confidence interval, -3.6 to 4.4) showed nonsignificance in a standard test for equality (P=0.83) and for noninferiority...

  17. Comparison of the quality of life after conventional versus off-pump coronary artery bypass surgery.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Stamou, Sotiris C; Petro, Kathleen R; Hill, Peter C; Boyce, Steven W; Bafi, Ammar S; Corso, Paul J

    2008-01-01

    Numerous studies have focused on off-pump coronary artery bypass graft (off-pump CABG) morbidity and mortality outcomes, but few looked at the patient's perception of the technique and its effect on postoperative quality of life (QOL). We investigated and compared postoperative QOL in patients who had undergone either conventional or off-pump CABG myocardial revascularization. During a six-month period, 191 patients who underwent CABG surgery were prospectively studied through preoperative and six-month postoperative short-form 36 (SF-36) general health status surveys. One hundred-sixteen (60.7%) off-pump CABG patients and 75 (39.3%) conventional on-pump CABG patients were enrolled. Sixteen (13.8%) off-pump patients reported improvement in physical score QOL, 84 (72.4%) reported no change, and 16 (13.8%) reported a decrease. In comparison, 20 (80.0%) patients in the on-pump CABG group reported an improvement in QOL, 42 (56.0%) were unchanged, and 13 (17.3%) reported deterioration (p = 0.28). For postoperative change in mental score, 19 (16.4%) off-pump patients reported an improvement, 85 (73.3%) stayed unchanged, and 12 (10.3%) reported a decrease compared with 8 (10.7%) conventional CABG patients reporting improvement, 60 (80.0%) showing no change, and 7 (9.3%), having a score decline (p = 0.52). In multivariate logistic regression analysis, hypertension (odds ratio [OR] 2.2, 95% confidence intervals [CI], 1.08 to 4.40, p = 0.03) and multivessel coronary artery disease (OR 2.1, 95% CI, 1.11 to 4.13, p = 0.02) emerged as independent predictors of worse physical score component score. Diabetes was associated with an improved physical score component score after CABG (OR 0.4, 95% CI, 0.17 to 0.76, p = 0.01), regardless of the surgical approach. This prospective study reveals no significant differences in the expected QOL at six months after either on-pump or off-pump CABG. Patients with hypertension and multivessel coronary artery disease were more likely to have

  18. No major differences in 30-day outcomes in high-risk patients randomized to off-pump versus on-pump coronary bypass surgery: the best bypass surgery trial

    DEFF Research Database (Denmark)

    Møller, Christian H; Perko, Mario J; Lund, Jens T

    2010-01-01

    Off-pump coronary artery bypass grafting compared with coronary revascularization with cardiopulmonary bypass seems safe and results in about the same outcome in low-risk patients. Observational studies indicate that off-pump surgery may provide more benefit in high-risk patients. Our objective...... was to compare 30-day outcomes in high-risk patients randomized to coronary artery bypass grafting without or with cardiopulmonary bypass....

  19. A new beating-heart off-pump coronary artery bypass grafting training model

    NARCIS (Netherlands)

    Bouma, Wobbe; Kuijpers, Michiel; Bijleveld, Aanke; De Maat, Gijs E.; Koene, Bart M.; Erasmus, Michiel E.; Natour, Ehsan; Mariani, Massimo A.

    OBJECTIVES: Training models are essential in mastering the skills required for off-pump coronary artery bypass grafting (OPCAB). We describe a new, high-fidelity, effective and reproducible beating-heart OPCAB training model in human cadavers. METHODS: Human cadavers were embalmed according to the

  20. Platelet hyperreactivity in response to on- and off-pump coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Bochsen, Louise; Rosengaard, Lisbeth Bredahl; Nielsen, Allan Bybeck

    2009-01-01

    Hypercoagulability has been reported after off-pump coronary artery bypass grafting (OPCAB) compared with patients undergoing standard coronary artery bypass grafting (CABG) with cardiopulmonary bypass. The aim of this study was to evaluate the changes in platelet reactivity in response to cardiac...... and this study identified 23% of patients needing coronary bypass surgery to be at high risk for recurrent ischemic events at 1 month after surgery, based on the MA. These results suggest that a more aggressive antithrombotic treatment might be warranted for patients undergoing coronary artery bypass grafting...

  1. Distinct alterations in sublingual microcirculatory blood flow and hemoglobin oxygenation in on-pump and off-pump coronary artery bypass graft surgery

    NARCIS (Netherlands)

    Atasever, Bektaş; Boer, Christa; Goedhart, Peter; Biervliet, Jules; Seyffert, Jan; Speekenbrink, Ron; Schwarte, Lothar; de Mol, Bas; Ince, Can

    2011-01-01

    The authors hypothesized that cardiopulmonary bypass (CPB) (on-pump) is associated with more severe changes in the microcirculatory blood flow and tissue oxygenation as compared with off-pump coronary artery bypass surgery. An observational study. A university hospital and teaching hospital.

  2. Peripheral tissue metabolism during off-pump versus on-pump coronary artery bypass graft surgery: the microdialysis study.

    Science.gov (United States)

    Pojar, Marek; Mand'ák, Jirí; Cibícek, Norbert; Lonský, Vladimír; Dominik, Jan; Palicka, Vladimír; Kubícek, Jaroslav

    2008-05-01

    The aim of this study was to monitor and compare metabolic changes in the skeletal muscle during coronary artery bypass grafting surgery with and without cardiopulmonary bypass (CPB) by means of interstitial microdialysis. Glucose, lactate, pyruvate and glycerol were assessed as markers of basic metabolism and tissue perfusion. Twenty patients undergoing surgical myocardial revascularization were enrolled in this pilot study. Ten patients were operated on without CPB (group A, off-pump) and 10 patients using normothermic CPB (group B, on-pump). Interstitial microdialysis was performed by a CMA 60 (CMA/Microdialysis AB, Sweden) probe, inserted into the patient's left deltoid muscle. Microdialysis measurements were performed at 30 min intervals. Glucose, lactate, pyruvate and glycerol were measured in samples using a CMA 600 Analyser (CMA/Microdialysis AB, Sweden). Results in both groups were statistically processed and the groups were compared. Both groups were similar with regards to preoperative characteristics. Dynamic changes of interstitial concentrations of the measured analytes were found in off-pump (group A) and on-pump (group B) patients during the operation. There were no significant differences in dialysate concentrations of glucose and lactate between the groups. Significant differences were detected in pyruvate concentrations, lactate-pyruvate ratio and glycerol concentrations between off-pump versus on-pump patients. Pyruvate concentrations were higher in the off-pump group (plactate-pyruvate ratios indicating the aerobic/anaerobic metabolism status were lower in the off-pump group (pglucose, glycerol, pyruvate and lactate were found in both groups of patients (off-pump and on-pump). The presented preliminary results suggest that extracorporeal circulation during cardiac operations could compromise skeletal muscle energy metabolism.

  3. Anesthesia for off-pump coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Thomas M Hemmerling

    2013-01-01

    Full Text Available The evolution of techniques and knowledge of beating heart surgery has led anesthesia toward the development of new procedures and innovations to promote patient safety and ensure high standards of care. Off-pump coronary artery bypass (OPCAB surgery has shown to have some advantages compared to on-pump cardiac surgery, particularly the reduction of postoperative complications including systemic inflammation, myocardial injury, and cerebral injury. Minimally invasive surgery for single vessel OPCAB through a limited thoracotomy incision can offer the advantage of further reduction of complications. The anesthesiologist has to deal with different issues, including hemodynamic instability and myocardial ischemia during aorto-coronary bypass grafting. The anesthesiologist and surgeon should collaborate and plan the best perioperative strategy to provide optimal care and ensure a rapid and complete recovery. The use of high thoracic epidural analgesia and fast-track anesthesia offers particular benefits in beating heart surgery. The excellent analgesia, the ability to reduce myocardial oxygen consumption, and the good hemodynamic stability make high thoracic epidural analgesia an interesting technique. New scenarios are entering in cardiac anesthesia: ultra-fast-track anesthesia with extubation in the operating room and awake surgery tend to be less invasive, but can only be performed on selected patients.

  4. The clinical research of off-pump coronary artery bypass grafting by small incision at the left chest.

    Science.gov (United States)

    Xiao, L-B; Zhang, Y-H; Zhou, J-W; Yang, M; Ling, Y-P; Gao, Z-S; Wang, Y-S

    2016-01-01

    To explore the clinical value of off-pump coronary artery bypass grafting by small incision at the left chest, and develop a better surgical regimen for coronary heart disease patients. 201 coronary heart disease patients who need coronary artery bypass grafting were required and randomly divided into 2 groups including a control group and an observation group. There were 107 cases in the control group who received coronary bypass grafting by extracorporeal circulation; there were 103 cases in the observation group who received off-pump coronary bypass grafting by small incision at the left chest. The duration of the mechanism ventilation, length of stay in ICU, hospitalization time, postoperative drainage volume, and the occurrence rate of complications were recorded and compared. The duration of mechanism ventilation, length of stay in ICU, hospitalization time and postoperative drainage volume in the control group were (19.21 ± 1.33) hours, (5.08 ± 0.57) days, (21.20 ± 2.34) days and (997.68 ± 96.35) mL, which were (7.73 ± 0.74) hours, (2.83 ± 0.16) days, (15.67 ± 1.18) days and (901.53 ± 89.32) mL in the observation group respectively, with statistical difference between the two groups (pdisease, pulmonary infection, perioperative cardiac infarction and mortality did not display a significant difference between the two groups (p > 0.05). Off-pump coronary artery bypass grafting by small incision at the left chest is a surgical method with less injury and fast recovery, which can be used as the preferred therapeutical method for the coronary heart disease patients who need coronary artery bypass grafting.

  5. Effects of continuous administration of clopidogrel before off-pump coronary artery bypass grafting in patients with acute coronary syndrome. A propensity score analysis

    International Nuclear Information System (INIS)

    Song, Suk-Won; Youn, Young-Nam; Yi, Gijong; Lee, Sak; Yoo, Kyung-Jong

    2008-01-01

    Clopidogrel has become standard treatment after urgent percutaneous coronary revascularization. Due to its enhanced and irreversible platelet inhibition, patients undergoing urgent surgical revascularization have a higher risk of bleeding complications and transfusions. Therefore, the effect of preoperative continuous administration of clopidogrel on the incidence of hemorrhagic complications in patients undergoing off-pump coronary artery bypass surgery with acute coronary syndrome was evaluated. From March 2004 to September 2006, 172 patients with acute coronary syndrome underwent isolated off-pump coronary artery bypass surgery; 70 (40.7%) and 102 (59.3%) of these patients did or did not take clopidogrel before surgery respectively. Seventy patients in each group were matched using propensity scores and associations between preoperative continuous administration of clopidogrel and postoperative bleeding, hemostatic reoperation, blood products received, the need for multiple transfusions and early graft patency by coronary computed tomography were assessed. Univariate analysis showed the continuous clopidogrel group had similar levels of postoperative bleeding for 24 h (601.4±312.6 ml vs 637.2±452.4 ml, p=0.616) and rates of reexploration (1.4% vs 1.4%), perioperative blood transfusion (33.3% vs 34.3%, p>0.05) and platelet transfusion (2.9% vs 7.1%, p=0.44) compared with the non-continuous group. Preoperative continuous administration of clopidogrel did not increase the risk of hemorrhagic complications in patients with acute coronary syndrome undergoing isolated off-pump coronary artery bypass surgery. These findings indicate that surgery after clopidogrel treatment in patients with acute coronary syndrome should not be delayed until platelet function returns to normal because they may have a higher risk of recurrent myocardial ischemic events. (author)

  6. Sodium bicarbonate does not prevent postoperative acute kidney injury after off-pump coronary revascularization: a double-blinded randomized controlled trial.

    Science.gov (United States)

    Soh, S; Song, J W; Shim, J K; Kim, J H; Kwak, Y L

    2016-10-01

    Acute kidney injury (AKI) is a common morbidity after off-pump coronary revascularization. We investigated whether perioperative administration of sodium bicarbonate, which might reduce renal injury by alleviating oxidative stress in renal tubules, prevents postoperative AKI in off-pump coronary revascularization patients having renal risk factors. Patients (n=162) having at least one of the following AKI risk factors were enrolled: (i) age >70 yr; (ii) diabetes mellitus; (iii) chronic renal disease; (iv) congestive heart failure or left ventricular ejection fraction 24 h) relative to the control group (20 vs 6, P=0.003). Perioperative sodium bicarbonate administration did not decrease the incidence of AKI after off-pump coronary revascularization in high-risk patients and might even be associated with a need for prolonged ventilatory care. NCT01840241. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Postoperative Functional Outcome After Off-Pump Versus On-Pump Coronary Artery Bypass Grafting Using Gated Myocardial SPECT: A Comparison by Propensity Score Analysis

    International Nuclear Information System (INIS)

    Lee, Jong Jin; Paeng, Jin Chul; Lee, Dong Soo; Kim, Ki Bong; Chung, June Key; Lee, Myung Chul; Kang, Won Jun

    2010-01-01

    We evaluated the short-term and mid-term differences in perfusion and function after off-pump and on-pump coronary artery bypass grafting (CABG) using gated myocardial single photon emission computed tomography. A total of 70 patients with coronary artery disease who underwent CABG were included based on the propensity score matching results from 165 patients. Thirty-five patients underwent off-pump and 35 patients on-pump CABG. Rest 201 TI/dipyridamole stress 99m Tc-methoxyisobutylisonitrile gated single photon emission computed thermographs were performed preoperatively and postoperatively at short-term (103±23 days after surgery) and mid-term follow-up (502±111 days after surgery). Changes in left ventricular ejection fraction, end systolic volume, stress and rest segmental perfusion, and segmental wall thickening were compared between the two groups. The segments with preoperative rest 201 T1 uptake under 60% of maximum uptake were included in the segmental analysis. Left ventricular ejection fraction (P=0.001) and end systolic volume (P=0.008) showed significant improvement in both groups. There were no significant short-term and mid-term differences between the two groups in terms of left ventricular ejection fraction (P=0.309) and end systolic volume (P=0.938). Likewise, segmental rest (P=0.178) and stress perfusion (P=0.071), and systolic wall thickening (P=0.241) showed significant improvement in both groups with similar time courses. Off-pump CABG resulted in significant improvements in left ventricular ejection fraction, end systolic volume, and regional myocardial perfusion and function that are comparable to on-pump CABG at short-term and mid-term. Gated myocardial SPECT successfully revealed that off-pump CABG is as good as on-pump CABG from the viewpoint of myocardial perfusion and function.

  8. Anaortic off-pump versus clampless off-pump using the PAS-Port device versus conventional coronary artery bypass grafting: mid-term results from a matched propensity score analysis of 5422 unselected patients.

    Science.gov (United States)

    Furukawa, Nobuyuki; Kuss, Oliver; Preindl, Konstantin; Renner, André; Aboud, Anas; Hakim-Meibodi, Kavous; Benzinger, Michael; Pühler, Thomas; Ensminger, Stephan; Fujita, Buntaro; Becker, Tobias; Gummert, Jan F; Börgermann, Jochen

    2017-10-01

    Meta-analyses from observational and randomized studies have demonstrated benefits of off-pump surgery for hard and surrogate endpoints. In some of them, increased re-revascularization was noted in the off-pump groups, which could impact their long-term survival. Therefore, we analyzed the course of all patients undergoing isolated coronary surgery regarding the major cardiac and cerebrovascular event (MACCE) criteria. A prospective register was taken from a high-volume off-pump center recording all anaortic off-pump (ANA), clampless off-pump (PAS-Port) and conventional (CONV) coronary artery bypass operations between July 2009 and June 2015. Propensity Score Matching was performed based on 28 preoperative risk variables. We identified 935 triplets (N = 2805). Compared with CONV, in-hospital mortality of both the ANA group (OR for ANA [95% CI] 0.25 [0.06; 0.83], P = 0.021), and the PAS-Port group was lower (OR for PAS-Port [95% CI] 0.50 [0.17; 1.32], P = 0.17). In the mid-term follow-up there were no significant differences between the groups regarding mortality (HR for ANA [95%-CI] 0.83 [0.55-1.26], P = 0.38; HR for PAS-Port [95%-CI] 1.06 [0.70-1.59], P = 0.79), incidence of stroke (HR for ANA 0.81 [0.43-1.53], P = 0.52; HR for PAS-Port 0.78 [0.41-1.50], P = 0.46), myocardial infarction (HR for ANA 0.53 [0.22-1.31], P = 0.17; HR for PAS-Port 0.78 [0.37-1.66], P = 0.52) or re-revascularization rate (HR for ANA 0.99 [0.67-1.44], P = 0.94; HR for PAS-Port 0.95 [0.65-1.38], P = 0.77). Both off-pump clampless techniques were associated with lower in-hospital mortality compared with conventional CABG. The mid-term course showed no difference with regard to the MACCE criteria between anaortic off-pump, clampless off-pump using PAS-Port and conventional CABG. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Off-pump supra-arterial myotomy for myocardial bridging.

    Science.gov (United States)

    Crespo, Alejandro; Aramendi, José I; Hamzeh, Gadah; Voces, Roberto

    2008-09-01

    We report the results of surgery and midterm outcome in two patients with symptomatic myocardial bridging who underwent off-pump supra-arterial myotomy. Both patients were operated upon through a median sternotomy. The anterior wall of the heart was exposed in the same manner as in off-pump CABG. The left anterior descending coronary artery is unroofed from its myocardial bridge with the aid of a heart stabilizer and a blower. Neither heparin nor blood transfusion was required. Both patients survived the operation and are asymptomatic. Postoperative coronary angiogram showed good resolution of the muscle bridge in one patient. We conclude that in symptomatic patients with myocardial bridging despite medical therapy, surgical myotomy can be considered an adequate therapy. It can be safely done off-pump.

  10. Off-pump versus On-pump Coronary Artery Bypass Grafting in Frail Patients: Study Protocol for the FRAGILE Multicenter Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Omar Asdrúbal Vilca Mejía

    Full Text Available Abstract Introduction: Advances in modern medicine have led to people living longer and healthier lives. Frailty is an emerging concept in medicine yet to be explored as a risk factor in cardiac surgery. When it comes to CABG surgery, randomized controlled clinical trials have primarily focused on low-risk (ROOBY, CORONARY, elevated-risk (GOPCABE or high-risk patients (BBS, but not on frail patients. Therefore, we believe that off-pump CABG could be an important technique in patients with limited functional capacity to respond to surgical stress. In this study, the authors introduce the new national, multicenter, randomized, controlled trial "FRAGILE", to be developed in the main cardiac surgery centers of Brazil, to clarify the potential benefit of off-pump CABG in frail patients. Methods: FRAGILE is a two-arm, parallel-group, multicentre, individually randomized (1:1 controlled trial which will enroll 630 patients with blinded outcome assessment (at 30 days, 6 months, 1 year, 2 years and 3 years, which aims to compare adverse cardiac and cerebrovascular events after off-pump versus on-pump CABG in pre-frail and frail patients. Primary outcomes will be all-cause mortality, acute myocardial infarction, cardiac arrest with successful resuscitation, low cardiac output syndrome/cardiogenic shock, stroke, and coronary reintervention. Secondary outcomes will be major adverse cardiac and cerebrovascular events, operative time, mechanical ventilation time, hyperdynamic shock, new onset of atrial fibrillation, renal replacement therapy, reoperation for bleeding, pneumonia, length of stay in intensive care unit, length of stay in hospital, number of units of blood transfused, graft patency, rate of complete revascularization, neurobehavioral outcomes after cardiac surgery, quality of life after cardiac surgery and costs. Discussion: FRAGILE trial will determine whether off-pump CABG is superior to conventional on-pump CABG in the surgical treatment of

  11. Off-pump coronary bypass surgery adversely affects alveolar gas exchange.

    Science.gov (United States)

    Gasparović, Hrvoje; Unić, Daniel; Sutlić, Zeljko; Husedzinović, Ino; Biocina, Bojan; Rudez, Igor; Nikić, Nada; Jelić, Ivan

    2008-03-01

    While the introduction of off-pump myocardial revascularization (OPCAB) has initially shown promise in reducing respiratory complications inherent to conventional coronary surgery, it has failed to eradicate them. Our study focused on quantifying the lactate release from the lungs and the dysfunction at the level of the alveolar-capillary membrane precipitated by OPCAB at different time points after the insult. Furthermore, we aimed to determine the impact of pulmonary lactate production on systemic lactic acid concentrations. The study was conducted in a prospective observational fashion. Forty consecutive patients undergoing OPCAB were analyzed. The mean patient age was 60 +/- 10 years. The mean EUROScore was 3.8 +/- 2.9. The alveolar-arterial O2 gradient increased from 19 [range 9 to 30] to 26 [range 20 to 34] kPa (P pump myocardial revascularization was evidenced by a prompt increase in the alveolar-arterial oxygen gradient. The alveolar-arterial O2 gradient correlated with the duration of mechanical ventilation.

  12. Effects of preoperative aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in patients undergoing off-pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Shim, Jae Kwang; Choi, Yong Seon; Oh, Young Jun; Bang, Sou Ouk; Yoo, Kyung Jong; Kwak, Young Lan

    2007-07-01

    Preoperative exposure to clopidogrel and aspirin significantly increases postoperative bleeding in patients undergoing on-pump coronary artery bypass graft surgery. Off-pump coronary bypass grafting has been proposed as an alternative technique to attenuate postoperative bleeding associated with clopidogrel. This study aimed to determine the effects of aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in off-pump coronary artery bypass grafting. One hundred six patients scheduled for off-pump coronary artery bypass grafting were divided into three groups: aspirin and clopidogrel discontinued more than 6 days before surgery (group 1, n = 35), aspirin and clopidogrel continued until 3 to 5 days before surgery (group 2, n = 51), and both medications continued within 2 days of surgery (group 3, n = 20). Thromboelastographic tracings were analyzed before induction of anesthesia. Routine coagulation profiles were measured before and after surgery. A cell salvage device was used during surgery and salvaged blood was reinfused. Chest tube drainage and blood transfusion requirement were recorded postoperatively. Patient characteristics, operative data, and thromboelastographic tracings were similar among the groups. There were significant decreases in hematocrit level and platelet count and prolongation in prothrombin time postoperatively in all groups without any intergroup differences. The amounts of perioperative blood loss and blood transfusion required were all similar among the groups. Preoperative clopidogrel and aspirin exposure even within 2 days of surgery does not increase perioperative blood loss and blood transfusion requirements in patients undergoing elective off-pump coronary artery bypass grafting.

  13. Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Reza Arefizadeh

    2017-05-01

    CONCLUSIONS: Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR.

  14. Rare case-series of electrocautery burn following off-pump coronary artery bypass grafting

    Science.gov (United States)

    Sabzi, Feridoun; Niazi, Mojtaba; Ahmadi, Alireza

    2014-01-01

    Abstract: With an increasing number of off-pump coronary artery surgery procedures in high-risk patients with coagulopathy, including renal failure, hepatic failure and anticoagulant drug-using patients, the frequency of related complications such as repeated exploration for bleeding is also increasing. The associated co-morbidity and repeated use of electrocautery in postoperative bleeding leaves patients susceptible to electrocautery ulcers. In this case series, rare cases of cautery burn with unique causative mechanisms are described. PMID:23669602

  15. Intra-myocardial LAD: Is it a contraindication for off-pump coronary artery bypass grafting?

    Directory of Open Access Journals (Sweden)

    Ashraf Fawzy Mahmoud

    2018-03-01

    Full Text Available Background: The left anterior descending artery (LAD is the most important vessel in coronary artery bypass graft surgery (CABG. During CABG, LAD may be intra-myocardial for variable distances and depths. This forms a challenge during LAD exposure and anastomosis.The aim was to revise the performed CABG cases to elicit what was the incidence of intramyocardial LAD (IMLAD among all CABGs, to have an idea about the approaches to the IMLAD and the technique of anastomosis of left internal mammary artery (LIMA to IMLAD off-pump (OPCAB and to evaluate the validity and reliability of the off-pump for the IMLAD. Methods: Since September 2008 till May 2017; the data of 1138 Off-Pump CABGs were revised. 923 patients had epicardial LAD and it was visible and easily identified throughout 80% of its length; this was group A. 215 (18.89% patients had IMLAD; they were referred to as group B. Results: There were no statistical significant differences between both groups as regards the age, the sex, the risk factors or the duration of surgery. The post operative bleeding, ischemia, CCU stay and hospital stay were not statistically significant. Conversion to on-pump for the mere presence of an intramyocardial LAD was zero%, but it was 1.3% in group A and 1.86% in B due to hemodynamic instability during manipulations (statistically insignificant. Conclusions: The incidence of IMLAD was 18.89%. IMLAD was a real technical challenge. It was not impossible for exposure and anastomosisas off-pump. The IMLAD is not a contraindication for OPCAB. Keywords: IMLAD, OPCAB, LIMA/LAD

  16. Fibrinolytic Inhibitors in Off-pump Coronary Surgery: A Prospective, Randomized, Double-Blind TAP Study (Tranexamic Acid, Aprotinin, Placebo)

    Czech Academy of Sciences Publication Activity Database

    Vaněk, T.; Jareš, M.; Fajt, R.; Straka, Z.; Jirásek, K.; Kolesár, M.; Brůček, P.; Malý, Marek

    2005-01-01

    Roč. 28, č. 4 (2005), s. 563-568 ISSN 1010-7940 Source of funding: V - iné verejné zdroje Keywords : tranexamic acid * protinin * off-pump coronary artery bypass * hemostasis Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 1.802, year: 2005

  17. DOES TRANEXAMIC ACID REDUCE BLOOD LOSS IN OFF-PUMP CORONARY ARTERY BYPASS?

    Directory of Open Access Journals (Sweden)

    A. Mehr-Aein

    2006-09-01

    Full Text Available Tranexamic acid is now used on a routine basis for on-pump coronary artery bypass grafting (CABG. We assessed the hemostatic effects of tranexamic acid to decrease bleeding tendency and transfusion requirements in patients undergoing off-pump coronary artery bypass surgery (OPCAB. A total of 66 patients were enrolled to elective OPCAB in a double-blind, prospective randomized study. Of these, 33 patients received tranexamic acid (15 mg/kg before the infusion of heparin and 15 mg/kg after protamin infusion, and 33 patients received only saline. Preoperative hematologic variables, postoperative bleeding and allogeneic transfusions were considered. D-dimer plasma levels were also evaluated to monitor the activation of fibrinolysis. Postoperative bleeding was significantly lower in the tranexamic acid group compared with the control group (320 ± 38 mL vs. 480 ± 75 mL at 12 hour, P < 0.001. The tranexamic acid group had significantly lesser need for allogeneic blood products (0.46 units/patients vs. 0.94 units/patients, P < 0.001. They had also lower post-operative D-dimer plasma levels. No postoperative thrombotic complications were observed in either group. The defective hemostasis occurs even in the OPCABG. Tranexamic acid effectively reduces postoperative blood loss and the need for allogeneic blood products after OPCAB is decreased.

  18. Off-pump versus on-pump CABG in high-risk patients

    DEFF Research Database (Denmark)

    Linde, Jesper; Møller, Christian; Hughes, Pia

    2006-01-01

    During recent years Conventional Coronary Artery Bypass Grafting (cCABG) and Off-Pump Coronary Bypass (OPCAB) have been compared in several randomised and non-randomised studies. Focus has been on postoperative outcome with short-term follow-up in low-risk patients and therefore little is known...... of the effectiveness of OPCAB in high-risk patients. Furthermore, it is unknown if a potential beneficial short-term outcome is consistent over time....

  19. Off-pump coronary artery bypass surgery in selected patients is superior to the conventional approach for patients with severely depressed left ventricular function

    Science.gov (United States)

    Caputti, Guido Marco; Palma, José Honório; Gaia, Diego Felipe; Buffolo, Enio

    2011-01-01

    OBJECTIVES: Patients with coronary artery disease and left ventricular dysfunction have high mortality when kept in clinical treatment. Coronary artery bypass grafting can improve survival and the quality of life. Recently, revascularization without cardiopulmonary bypass has been presented as a viable alternative. The aim of this study is to compare patients with left ventricular ejection fractions of less than 20% who underwent coronary artery bypass graft with or without cardiopulmonary bypass. METHODS: From January 2001 to December 2005, 217 nonrandomized, consecutive, and nonselected patients with an ejection fraction less than or equal to 20% underwent coronary artery bypass graft surgery with (112) or without (off-pump) (105) the use of cardiopulmonary bypass. We studied demographic, operative, and postoperative data. RESULTS: There were no demographic differences between groups. The outcome variables showed similar graft numbers in both groups. Mortality was 12.5% in the cardiopulmonary bypass group and 3.8% in the off-pump group. Postoperative complications were statistically different (cardiopulmonary bypass versus off-pump): total length of hospital stay (days)—11.3 vs. 7.2, length of ICU stay (days)—3.7 vs. 2.1, pulmonary complications—10.7% vs. 2.8%, intubation time (hours)—22 vs. 10, postoperative bleeding (mL)—654 vs. 440, acute renal failure—8.9% vs. 1.9% and left-ventricle ejection fraction before discharge—22% vs. 29%. CONCLUSION: Coronary artery bypass grafting without cardiopulmonary bypass in selected patients with severe left ventricular dysfunction is valid and safe and promotes less mortality and morbidity compared with conventional operations. PMID:22189729

  20. Off-pump coronary artery bypass surgery in selected patients is superior to the conventional approach for patients with severely depressed left ventricular function

    Directory of Open Access Journals (Sweden)

    Guido Marco Caputti

    2011-01-01

    Full Text Available OBJECTIVES: Patients with coronary artery disease and left ventricular dysfunction have high mortality when kept in clinical treatment. Coronary artery bypass grafting can improve survival and the quality of life. Recently, revascularization without cardiopulmonary bypass has been presented as a viable alternative. The aim of this study is to compare patients with left ventricular ejection fractions of less than 20% who underwent coronary artery bypass graft with or without cardiopulmonary bypass. METHODS: From January 2001 to December 2005, 217 nonrandomized, consecutive, and nonselected patients with an ejection fraction less than or equal to 20% underwent coronary artery bypass graft surgery with (112 or without (off-pump (105 the use of cardiopulmonary bypass. We studied demographic, operative, and postoperative data. RESULTS: There were no demographic differences between groups. The outcome variables showed similar graft numbers in both groups. Mortality was 12.5% in the cardiopulmonary bypass group and 3.8% in the off-pump group. Postoperative complications were statistically different (cardiopulmonary bypass versus off-pump: total length of hospital stay (days-11.3 vs. 7.2, length of ICU stay (days-3.7 vs. 2.1, pulmonary complications-10.7% vs. 2.8%, intubation time (hours-22 vs. 10, postoperative bleeding (mL-654 vs. 440, acute renal failure-8.9% vs. 1.9% and left-ventricle ejection fraction before discharge-22% vs. 29%. CONCLUSION: Coronary artery bypass grafting without cardiopulmonary bypass in selected patients with severe left ventricular dysfunction is valid and safe and promotes less mortality and morbidity compared with conventional operations.

  1. Comparison of two doses of heparin on outcome in off-pump coronary artery bypass surgery patients: A prospective randomized control study

    Directory of Open Access Journals (Sweden)

    Murali Chakravarthy

    2017-01-01

    Full Text Available Introduction: While off pump coronary artery bypass surgery is practiced with an intention to reduce the morbidity associated with cardiopulmonary bypass, the resultant ′hypercoagulability′ needs to be addressed. Complications such as cavitary thrombus possibly due to the hyper coagulability after off pump coronary artery bypass surgery have been described. Many clinicians use higher doses of heparin - up to 5 mg/kg in order to thwart this fear. Overall, there appears to be no consensus on the dose of heparin in off pump coronary artery bypass surgeries. Aim of the Study: The aim of the study was understand the differences in outcome of such as transfusion requirement, myocardial ischemia, and morbidity when two different doses were used for systemic heparinization. Methods: Elective patients scheduled for off pump coronary artery bypass surgery were included. Ongoing anti platelet medication was not an exclusion criteria, however, anti platelet medications were ceased about a week prior to surgery when possible. Thoracic epidural anesthesia was administered as an adjunct in patients who qualified for it. By computer generated randomization chart, patients were chosen to receive either 2 or 3 mg/kg of intravenous unfractioned heparin to achieve systemic heparinization with activated clotting time targeted at >240 secs. Intraoperative blood loss, postoperative blood loss, myocardial ischemic episodes, requirement of intraaortic balloon counter pulsation and transfusion requirement were analyzed. Results: Sixty two patients participated in the study. There was one conversion to cardiopulmonary bypass. The groups had comparable ACT at baseline (138.8 vs. 146.64 seconds, P = 0.12; 3 mg/kg group had significantly higher values after heparin, as expected. But after reversal with protamine, ACT and need for additional protamine was similar among the groups. Intraoperative (685.56 ± 241.42 ml vs. 675.15 ± 251.86 ml, P = 0.82 and postoperative

  2. Off-pump myocardial revascularisation in an octogenarian patient with dextrocardia and situs inversus.

    Science.gov (United States)

    Ennker, I C; Pietrowski, D; Ennker, J

    2006-01-01

    Dextrocardia associated with situs inversus totalis is a rare condition and there are few reports of myocardial revascularisation in such patients. An 82-year-old woman with dextrocardia and situs inversus totalis underwent successful off-pump coronary artery bypass grafting using internal mammary arteries. The operative technique was similar to that of off-pump coronary artery bypass grafting for situs solitus. However, for a right-handed surgeon the operation was easier standing on the left side of the patient.

  3. Transcatheter aortic valve implantation and off-pump coronary artery bypass surgery: an effective hybrid procedure in selected patients.

    Science.gov (United States)

    Mayr, Benedikt; Firschke, Christian; Erlebach, Magdalena; Bleiziffer, Sabine; Krane, Markus; Joner, Michael; Herold, Ulf; Nöbauer, Christian; Lange, Rüdiger; Deutsch, Marcus-André

    2018-02-26

    Simultaneous surgical off-pump coronary revascularization and transcatheter aortic valve implantation (TAVI) as a hybrid procedure may be a therapeutic option for patients with a TAVI indication who are not suitable for percutaneous coronary intervention and for patients who have an indication for combined surgical aortic valve implantation and coronary artery bypass grafting but present with a porcelain aorta. Early outcomes of these patients are analysed in this study. From February 2011 to April 2017, hybrid TAVI/off-pump coronary artery bypass (OPCAB) was performed in 12 (60%) patients, hybrid TAVI/minimally invasive direct coronary artery bypass in 6 (30%) patients and staged TAVI/OPCAB in 2 (10%) patients. Endpoints of this study were 30-day mortality, device success and postoperative adverse events as defined by the updated Valve Academic Research Consortium (VARC-2). The median age at the time of surgery was 77 years [interquartile range (IQR), 70-81] with a median logistic EuroSCORE and Society of Thoracic Surgeons' Predicted Risk score of 16.1% (IQR, 9.3-28.1) and 3.9% (IQR, 2.2-5.6), respectively. The median Synergy between PCI with Taxus and Cardiac Surgery score was 16.5 (IQR, 9.8-22.8). TAVI implantation routes were transaortic in 9 (45%) patients, transapical and transfemoral in 5 (25%) patients each and transsubclavian in 1 (5%) patient. Complete myocardial revascularization was achieved in 75% of patients. Device success rate was 100%. Paravalvular aortic regurgitation did not exceed mild in any patient. Stroke/transient ischaemic attack, vascular complications and myocardial infarction were not observed. Re-exploration for bleeding was required in 1 (5%) patient. Thirty-day mortality was 0%. Hybrid OPCAB/MIDCAB and TAVI prove to be a safe and effective alternative treatment option in selected higher risk patients.

  4. Presentation of a quality management program in off-pump coronary bypass surgery.

    Science.gov (United States)

    Bougioukakis, Petros; Kluegl, Stefan J; Babin-Ebell, Joerg; Tagarakis, Giorgios I; Mandewirth, Martin; Zacher, Michael; Diegeler, Anno

    2014-01-01

    To increase the number of off-pump coronary procedures at our institution, a new surgical team was formed. The first 3 years of "learning period" were accompanied by a quality management program aimed to control and adjust the surgical process and to ensure the safety and quality of the procedure. All patients were operated on by the same surgeon between January 2004 and December 2006; all procedures were performed under the following quality management protocol. First, a flow chart regulated surgical and anesthetic details. Second, an online file, named "disturbance file," was used to report work flow interruption, disturbance, and intraoperative events, that is, myocardial ischemia, hypotension, conversion to cardiopulmonary bypass, and any violation of the protocol. Each event was coded with 1 point and added to a score (the higher the score is, the greater the disturbance). Outcome parameters known as major events-major cardiac and cerebral events: mortality within 30 days/myocardial infarction confirmed by electrocardiogram or significantly high levels of total creatine kinase-myocardial muscle creatine kinase/reintervention within 30 days/stroke--and new-onset dialysis were also measured. Success was defined as freedom from any of those events and depicted in a cumulative sum control (CUSUM) chart. Outcome data and CUSUM were correlated with the intraoperative Disturbance Index. In total, 490 off-pump coronary bypass operations were performed by the named surgeon during the study period. The 30-day mortality was reduced from 4.0% to 1.9%. Disturbance Index score of greater than 1 declined from 41.6% to 23.3%. All major cardiac and cerebral events declined. The CUSUM chart showed two critical periods during the learning period, which made an adjustment of the protocol necessary. Quality management control is efficient in improving the postoperative results of a surgical procedure. A learning period is of cardinal importance for any new team wishing to engage

  5. Influence of body size on outcomes of off-pump coronary artery bypass surgery.

    Science.gov (United States)

    Yap, Alexander; Baladi, Naoum; Zapolanski, Alex; Pliam, Michael B; Shaw, Richard E

    2005-01-01

    Patients of small physical stature may be more likely selected for an on-pump coronary artery surgery (ONCAB) rather than an off-pump procedure (OPCAB). Small patients who do have OPCAB may do poorly. Our hospital demographics afford a unique opportunity to examine a group of small patients. Information was available over the past 4 years on 1015 patients who had isolated CABG and a calculable body surface area. Sixty-one patients had a body surface area of less than 1.5 m2 (SMALL). The 954 remaining patients were classed as larger (LARGER). Patients were compared with respect to preoperative risk factors, operative procedures, and postoperative results. Among SMALL patients, 59% were Asian, 89% female, averaged slightly older, had higher STS risk scores, lower hematocrits, more severe NYHA class ratings, and less elective surgical status (P < .05) than LARGER patients. Fifty-one percent of SMALL patients had OPCAB, 44.3% received blood, 90% had an event-free course, and 4.9% died postop (versus 1.2%, P < .05). OPCAB mortality was lower than ONCAB for both SMALL and nonsmall (P < .05). Blood use was greater for SMALL than for LARGER (44% versus 20%, P < .05) but less for SMALL OPCAB than SMALL ONCAB (27% versus 62%, P < .05). No differences were noted in postop MI, CVA, or length of stay, but 30-day readmission was lower for SMALL patients (5.0% versus 7.4%). Patients with small physical stature can be safely operated upon using off-pump techniques with good revascularization and postop results, despite apparently higher preop STS risk scores.

  6. Off-Pump Repair of a Post Myocardial Infarction Ventricular Septal Defect

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2014-01-01

    Full Text Available Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated and external sandwich closure of post myocardial ventricular septal defect (VSD appears to be simple and effective after initial myocardial infarction (MI. The three cases presented with a VSD after of acute MI with or without thrombolysed with streptokinase during patient admission. The general condition of the three patients was poor with pulmonary edema, low cardiac output and renal failure. The heart was approached through a median sternotomy. Off-pump coronary artery bypass grafting of the coronary artery lesion was done first using octopus and beating heart surgery method and latero - lateral septal plication was performed using sandwich technique. Low cardiac output managed with intra-aortic balloon pump in these patients accompanied with inotropic drugs. Post-operative transesophageal echocardiography revealed that VSD was closed completely in one patient and in two patients small residual VSD remained. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs.

  7. Postoperative chest radiographic changes after on- and off-pump coronary surgery

    International Nuclear Information System (INIS)

    Narayan, P.; Caputo, M.; Jones, J.; Al-Tai, S.; Angelini, G.D.; Wilde, P.

    2005-01-01

    AIM: A variety of chest radiograph abnormalities are recognized after coronary artery bypass grafting (CABG). This study analyzes the appearance of preoperative and postoperative chest radiographs in two groups of patients undergoing myocardial revascularization with or without the use of cardiopulmonary bypass (CPB). METHODS: Chest radiographs (preoperative and at 1 day, 6 days and 6 to 8 weeks post operatively) were analyzed according to a detailed protocol in cases of conventional CABG on CPB (n=60) or off-pump coronary artery bypass (OPCAB) (n=60) surgery. On each film 17 different major potential postoperative abnormalities were analyzed. RESULTS: Clinical findings were similar in the two groups. Patients undergoing OPCAB surgery had decreased blood loss, decreased red cell and platelet transfusion, significantly lower intubation time and required less postoperative inotropic support compared with patients undergoing CPB. The CPB group had a significantly higher incidence of left band atelectasis than the OPCAB group (37.6% vs 17.5%, p=0.01) at 6 days postoperatively. There was no other statistically significant difference in any of the 16 remaining major chest radiograph findings between the two groups. CONCLUSION: Although OPCAB surgery is associated with improved clinical outcome compared with conventional CABG surgery, the analysis of postoperative chest radiographs demonstrated only a minor benefit as shown by a reduced degree of left band atelectasis in the OPCAB group

  8. Postoperative chest radiographic changes after on- and off-pump coronary surgery

    Energy Technology Data Exchange (ETDEWEB)

    Narayan, P. [Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Caputo, M. [Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Jones, J. [Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); Al-Tai, S. [Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); Angelini, G.D. [Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Wilde, P. [Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom)]. E-mail: peter.wilde@ubht.swest.nhs.uk

    2005-06-01

    AIM: A variety of chest radiograph abnormalities are recognized after coronary artery bypass grafting (CABG). This study analyzes the appearance of preoperative and postoperative chest radiographs in two groups of patients undergoing myocardial revascularization with or without the use of cardiopulmonary bypass (CPB). METHODS: Chest radiographs (preoperative and at 1 day, 6 days and 6 to 8 weeks post operatively) were analyzed according to a detailed protocol in cases of conventional CABG on CPB (n=60) or off-pump coronary artery bypass (OPCAB) (n=60) surgery. On each film 17 different major potential postoperative abnormalities were analyzed. RESULTS: Clinical findings were similar in the two groups. Patients undergoing OPCAB surgery had decreased blood loss, decreased red cell and platelet transfusion, significantly lower intubation time and required less postoperative inotropic support compared with patients undergoing CPB. The CPB group had a significantly higher incidence of left band atelectasis than the OPCAB group (37.6% vs 17.5%, p=0.01) at 6 days postoperatively. There was no other statistically significant difference in any of the 16 remaining major chest radiograph findings between the two groups. CONCLUSION: Although OPCAB surgery is associated with improved clinical outcome compared with conventional CABG surgery, the analysis of postoperative chest radiographs demonstrated only a minor benefit as shown by a reduced degree of left band atelectasis in the OPCAB group.

  9. Perioperative outcomes in minimally invasive direct coronary artery bypass versus off-pump coronary artery bypass with sternotomy.

    Science.gov (United States)

    Tekin, Ali İhsan; Arslan, Ümit

    2017-09-01

    Surgical treatment of isolated left anterior descending coronary artery disease can be performed with either minimally invasive direct coronary artery bypass via a left anterior thoracotomy (MIDCAB) or off-pump coronary artery bypass via a median sternotomy (OPCAB). To compare the perioperative outcomes of patients undergoing MIDCAB or OPCAB surgery. Patients who underwent either MIDCAB or OPCAB for isolated left anterior descending (LAD) coronary artery disease between October 2013 and December 2015 were retrospectively evaluated. Operations were carried out by the same surgical team. Preoperative, intraoperative and postoperative data of the patients were recorded for analyses. Twenty-three patients (7 females, 16 males) underwent MIDCAB surgery, and 24 patients (4 female, 20 males) underwent OPCAB surgery. The two groups were comparable regarding preoperative patient characteristics. Duration of mechanical ventilation (5.1 ±0.7 h vs. 6.6 ±0.9 h), intensive care unit stay (19.4 ±2.5 h vs. 45.8 ±5.4 h) and hospital stay (4.3 ±0.4 days vs. 5.6 ±0.8 days) were significantly shorter in the MIDCAB group (p < 0.01). Patients in the OPCAB group required significantly more blood transfusions (1.83 ±0.38 units vs. 0.17 ±0.38 units) and fresh frozen plasma use (2.33 ±0.96 units vs. 0.69 ±0.76 units) (p < 0.01). Conversion to sternotomy was not required in the MIDCAB group. There was no mortality, conversion to cardiopulmonary bypass or serious complication in either group. We believe that the MIDCAB technique is more advantageous than the OPCAB technique in the treatment of patients with a critical LAD lesion.

  10. Off-pump Coronary Artery Bypass Graft in a High Risk Patient ...

    African Journals Online (AJOL)

    On-pump coronary artery bypass graft (CABG) entails the use of cardiopulmonary bypass (CPB). The procedure is safe but it's not without complications like neurocognitive deficits, cerebrovascular accidents, myocardial ischemic injury and activation of inflammatory pathways that contribute to pulmonary, renal, hematologic ...

  11. Results of completion arteriography after minimally invasive off-pump coronary artery bypass.

    Science.gov (United States)

    Hoff, Steven J; Ball, Stephen K; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Petracek, Michael R; Ahmad, Rashid; Greelish, James P; Walker, Kristie; Byrne, John G

    2011-01-01

    The benefits of a minimally invasive approach to off-pump coronary artery bypass remain controversial. The value of completion arteriography in validating this technique has not been investigated. From April 2007 to October 2009, fifty-six patients underwent isolated minimally invasive coronary artery bypass grafting through a left thoracotomy without cardiopulmonary bypass. Forty-three of these patients underwent completion arteriography. Sixty-five grafts were performed in these 56 patients, (average, 1.2 grafts per patient; range, 1 to 3). Forty-eight grafts were studied in the 43 patients undergoing completion arteriography. There were 4 findings on arteriogram leading to further immediate intervention (8.3%). These included 3 grafts with anastomotic stenoses or spasm requiring stent placement, and 1 patient who had limited dissection in the left internal mammary artery graft and underwent placement of an additional vein graft. These findings were independent of electrocardiographic changes or hemodynamic instability. The remainder of the studies showed no significant abnormalities. There were no deaths. One patient who did not have a completion arteriogram suffered a postoperative myocardial infarction requiring stent placement for anastomotic stenosis. Patients were discharged home an average of 6.8 days postoperatively. There were no instances of renal dysfunction postoperatively attributable to catheterization. Minimally invasive coronary artery bypass is safe and effective. Findings of completion arteriography occasionally reveal previously under-recognized findings that, if corrected in a timely fashion, could potentially impact graft patency and clinical outcomes. Our experience validates this minimally invasive technique. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Pathway-related modules involved in the application of sevoflurane or propofol in off-pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Bu, Xiangmei; Wang, Bo; Wang, Yaoqi; Wang, Zhigang; Gong, Chunzhi; Qi, Feng; Zhang, Caixia

    2017-07-01

    Off-pump coronary artery bypass graft (CABG) surgery has recently emerged as a means to avoid the sequelae of extracorporeal circulation, including the whole-body inflammatory response, coagulation disorders and multiple organ dysfunction. At present, gas anesthesia, sevoflurane and intravenous anesthesia and propofol have been widely used during the CABG. To further understand the underlying mechanisms of these anesthetics on the gene level, the present study conducted pathway-related module analysis based on a co-expression network. This was performed in order to identify significant pathways in coronary artery disease patients who had undergone off-pump CABG surgery before and after applying sevoflurane or propofol. A total of 269 and 129 differentially expressed genes were obtained in the sevoflurane and propofol groups, respectively. In total, eight and seven pathways (P<0.05) in the sevoflurane and propofol groups were separately obtained via Kyoto Encyclopedia of Genes and Genome pathway analysis. Finally, eight and seven pathway-related modules in the sevoflurane and propofol groups were obtained, respectively. Furthermore, the mean degree of complement and coagulation cascades pathway-related module in both of the groups was the highest. It was predicted that during the CABG, the anesthetics might activate the complement and coagulation systems in order to possess some cardioprotective properties.

  13. The Predictive Value of Integrated Pulmonary Index after Off-Pump Coronary Artery Bypass Grafting: A Prospective Observational Study

    Directory of Open Access Journals (Sweden)

    Evgenia V. Fot

    2017-08-01

    Full Text Available BackgroundThe early warning scores may increase the safety of perioperative period. The objective of this study was to assess the diagnostic and predictive role of Integrated Pulmonary Index (IPI after off-pump coronary artery bypass grafting (OPCAB.Materials and MethodsForty adult patients undergoing elective OPCAB were enrolled into a single-center prospective observational study. We assessed respiratory function using IPI that includes oxygen saturation, end-tidal CO2, respiratory rate, and pulse rate. In addition, we evaluated blood gas analyses and hemodynamics, including ECG, invasive arterial pressure, and cardiac index. The measurements were performed after transfer to the intensive care unit, after spontaneous breathing trial and at 2, 6, 12, and 18 h after extubation.Results and DiscussionThe value of IPI registered during respiratory support correlated weakly with cardiac index (rho = 0.4; p = 0.04 and ScvO2 (rho = 0.4, p = 0.02. After extubation, IPI values decreased significantly, achieving a minimum by 18 h. The IPI value ≤9 at 6 h after extubation was a predictor of complicated early postoperative period (AUC = 0.71; p = 0.04 observed in 13 patients.ConclusionIn off-pump coronary surgery, the IPI decreases significantly after tracheal extubation and may predict postoperative complications.

  14. Effects of dexmedetomidine on heart arrhythmia prevention in off-pump coronary artery bypass surgery: A randomized clinical trial.

    Science.gov (United States)

    Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima

    2017-10-01

    Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes

  15. Oxidative stress and homocyteine metabolism following coronary artery grafting by on pump and off pump CABG techniques

    International Nuclear Information System (INIS)

    Parvizi, R.; Noubar, R.; Salmasi, H.S.

    2007-01-01

    To compare the effect of on-pump and off-pump CABG on the induction of the oxidative stress and the metabolism of homocysteine, which is involved in the synthesis of glutathione. This retrospective study was performed in Shahid Madani Heart Hospital in Tabriz, Iran in 2004 using a questionnaire. Plasma homocysteine, folate total antioxidant capacity (TAC) and malonedialdehyde (MDA) were determined on blood samples obtained from 40 patients undergoing CABG, preoperatively and at 0,12,48,120 hours and 6 months after surgery. The patients were divided into two matched groups, one off-pump and the other on-pump CABG. A marked reduction of homocysteine, folate and significant elevation of MDA were noticed at 0, 12, 48 hours after operation in the both groups (P<0.05). A negative and marked correlation between homocysteine and TAC but a positive and significant between homocysteinc and MDA were observed (P<0.05 in the both groups). In CABG operation because of oxidative stress and consumption of GSH immediate reduction in the plasma levels of homocyticine occurs in the both techniques. However using off pump CABG induction of oxidative stress and changes in plasma levels of homocysteine are not as high as on- pump CABG. (author)

  16. Mid-term results of off-pump coronary artery bypass grafting assessed by multi-slice computed tomography

    International Nuclear Information System (INIS)

    Yoshida, Seijiro; Nitta, Yoshio; Oda, Katsuhiko

    2004-01-01

    Off-pump coronary artery bypass (OPCAB) has recently increased in popularity, but the long-term results are still unknown. We evaluated the mid-term results of OPCAB surgery using multi-slice computed tomography (MSCT), which is a non-invasive postoperative evaluation method. Thirty-one consecutive patients who underwent OPCAB surgery at least 2 years prior to the study were selected. The age was 50 to 79 years (66.9±6.5) and the ratio of men to women was 26:5. Coronary angiography was performed in all patients at 2 weeks postoperatively. The follow-up was complete, and mean follow-up was 30.9 months. There were no hospital deaths and 1 non-cardiac late death. The graft patency rate in coronary angiography was left internal thoracic artery (LITA) 30/30 (100%), right internal thoracic artery (RITA) 2/2 (100%), radial artery (RA) 14/15 (93%), saphenous vein graft (SVG) 15/17 (88%). No graft became occluded on MSCT study and all patients have been angina-free during the follow-up period. We suggest that OPCAB is feasible in most patients with good patency and low mortality. MSCT is an effective follow up method for the morphological findings and noninvasive quantitative evaluation of the bypass grafts. (author)

  17. Investigation of the effect of Acute Normovolemic Hemodilution and Tranexamic Acid on the amount of bleeding during off-pump coronary artery bypass graft surgery: a systematic review

    Directory of Open Access Journals (Sweden)

    Reza Jalaeian Taghadoomi

    2017-01-01

    Full Text Available Introduction: Postoperative bleeding and transfusion remain a source of morbidity and cost after open heart operations . To evaluate the effect of ANH method and tranexamic acid on blood transfusion requirements and blood loss after off pump coronary artery bypass surgery (OPCAB. Materials and Methods: The Cochrane Central Register of Controlled Trials, MEDLINE, and EMBASE from inception to December 2014; reference lists of published guidelines, reviews, and associated articles, as well as conference proceedings.We included articles with available abstract in English language. Manual searching was done within the reference list of articles. Three reviewers independently reviewed and assessed eligibility criteria, assessed quality, and extracted data. Results: Bleeding and hemorrhagic complications and the consequent need for allogeneic transfusion are still major problems after off-pump coronary artery bypass surgery that can reduced in combination of ANH method and tranexamic acid. Conclusion: Tranexamic acid and ANH appear to be effective in reducing postoperative bleeding and the need for allogeneic blood products.

  18. Right atrium positioning for exposure of right pulmonary veins during off-pump atrial fibrillation ablation.

    Science.gov (United States)

    Suwalski, Grzegorz; Emery, Robert; Mróz, Jakub; Kaczejko, Kamil; Gryszko, Leszek; Cwetsch, Andrzej; Skrobowski, Andrzej

    2017-06-01

    Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF. Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course. In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients. This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Frequency of Acute Kidney Injury in Patients Treated With Normal Saline after Off-Pump Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Shima Sheybani

    2017-03-01

    Full Text Available Introduction: Acute kidney injury (AKI is a common postoperative complication of cardiac surgery, which is associated with an increased risk of morbidity and mortality. This study investigated the frequency of postoperative AKI in low risk adult patients undergoing off-pump coronary artery bypass grafting (CABG.Materials & Methods: All consecutive adult patients of American Society of Anesthesiologists (ASA class II and III, who were transferred to the post-operative cardiac surgery ICU after off-pump CABG and were low risk for AKI from October 2013 to September 2014 at Emam Reza Hospital, Mashhad, Iran were enrolled in this prospective cohort study at a teaching hospital. The patients were explored for AKI development, based on risk-injury-failure-loss- end stage kidney disease (RIFLE and acute kidney injury network (AKIN criteria, frequency of metabolic acidosis, hypernatremia, hyperchloremia, and length of stay in ICU.Results: According to the results of the present study, 479 patients with the mean age of 60.8±10.75 yrs were included. AKI occurred in 22 (4.4% and23 (4.8% patients, based on both the RIFLE and AKIN criteria, respectively with the highest rate of AKI, reported on the third and fourth post-operative days. Additionally, hyperchloremia and hypernatremia were observed in 71 (14.8% and 76 (15.9% patients, respectively. Only one case of mortality occurred during the study. Metabolic acidosis was reported in 112 (23.4% patients with a high anion gap in 60 (12.5% cases.Conclusion: The current study demonstrated that hypernatremia and metabolic acidosis but not AKI are frequently seen in patients receiving normal saline following off pump CABG with low risk for AKI.

  20. Hemoglobin Level to Facilitate Off-Pump Coronary Artery Bypass without Transfusion.

    Science.gov (United States)

    Kim, Kun Il; Lee, Won Yong; Ko, Ho Hyun; Kim, Hyoung Soo; Jeong, Jae Han

    2014-08-01

    Conservation of blood during cardiac surgery is important because of the shortage of donor blood, risks associated with transfusion, and the costs of allogeneic blood products. This retrospective study explored the feasibility of off-pump coronary artery bypass (OPCAB) without transfusion. One hundred and two consecutive patients underwent OPCAB from January 2007 to June 2012 at Hallym University Sacred Heart Hospital. Excluding 10 chronic renal failures patients, 102 patients were enrolled. Their characteristics, clinical data, and laboratory data were analyzed. We investigated the success rate of OPCAB without transfusion according to pre-operative hemoglobin (Hb), and the cutoff point of the Hb level and the risk factors for transfusion. We implemented multidisciplinary blood-saving protocols. The overall operative mortality and the success rate of OPCAB without transfusion were 2.9% (3/102) and 73.5% (75/102). The success rates in patients with Hb70 years, diagnosis of acute myocardial infarction, preoperative Hb and creatinine levels, and operation time. The events precipitating the need for transfusion were low Hb level in 9 patients and hypotension or excessive bleeding in 18 patients. The preoperative Hb level of >11 facilitates OPCAB without transfusion. These results suggest that transfusion-free OPCAB can be performed by modifying the risk factors and correctable causes of transfusion and improving various blood salvage methods.

  1. Mid-term follow-up outcomes of 2-staged hybrid coronary revascularization compared with off-pump coronary artery bypass for patients with multivessel coronary artery disease.

    Science.gov (United States)

    Wu, Song; Ling, Yunpeng; Fu, Yuanhao; Zhang, Lufeng; Yang, Hang; Guo, Lijun; Gao, Wei; Wan, Feng

    2017-06-01

    Two-staged hybrid coronary revascularization (HCR) is a novel procedure in selected patients with multivessel coronary artery disease. However, few studies are available on the mid-term or long-term outcomes of this 2-staged procedure as compared to off-pump coronary artery bypass (OPCAB). To compare in-hospital and mid-term follow-up outcomes of 2-staged HCR with OPCAB in patients with multivessel coronary artery disease. The present retrospective study analyzed the data from 73 patients who underwent the 2-staged HCR (HCR group) during 2012-2014 at the heart center. Three hundred and eighty-three patients who underwent conventional OPCAB by the same surgeon were selected for the comparative analysis performed on in-hospital and mid-term follow-up outcomes between the two groups. No significant difference was observed in the preoperative outcome between the two groups. The HCR group had a shorter operation duration (152.9 ±43.8 vs. 262.6 ±51.8 min, p < 0.05), less bleeding (558.6 ±441.3 vs. 1035.5 ±613.3 ml, p < 0.05), shorter mechanical ventilation (9.4 ±7.4 vs. 19.0 ±18.3 h, p < 0.05), and less blood transfusion (12 (16.4%) vs. 200 (52.2%), p < 0.05). The mean follow-up duration was 25.0 ±9.6 months in the HCR group and 22.8 ±10.6 months in the OPCAB group. The incidence of major adverse cardiac or cerebrovascular events (MACCE) was similar in both groups (4 (5.5%) vs. 10 (2.8%), p = 0.408). The estimated 3-year survival was similar in both groups (log-rank χ 2 = 1.041, p = 0.308). The 2-staged HCR is a safe and effective surgical procedure and may offer similar mid-term follow-up outcomes to OPCAB.

  2. Pleural subxyphoid drain confers better pulmonary function and clinical outcomes in chronic obstructive pulmonary disease after off-pump coronary artery bypass grafting: a randomized controlled trial.

    Science.gov (United States)

    Guizilini, Solange; Viceconte, Marcela; Esperança, Gabriel Tavares da M; Bolzan, Douglas W; Vidotto, Milena; Moreira, Rita Simone L; Câncio, Andréia Azevedo; Gomes, Walter J

    2014-01-01

    To evaluate the lung function and clinical outcome in severe chronic obstructive pulmonary disease in patients undergoing off-pump coronary artery bypass grafting with left internal thoracic artery graft, comparing the pleural drain insertion in the intercostal versus subxyphoid region. A randomized controlled trial. Chronic obstructive pulmonary disease patients were randomized into two groups according pleural drain site: II group (n=27) - pleural drain in intercostal space; SI group (n=29) - pleural drain in the subxyphoid region. Spirometry values (Forced Vital Capacity - and Forced expiratory volume in 1 second) were obtained on preoperative and 1, 3 and 5 postoperative days. Chest x-ray from preoperative until postoperative day 5 (POD5) was performed for monitoring respiratory events, such as atelectasis and pleural effusion. Pulmonary shunt fraction and pain score was evaluate preoperatively and on postoperative day 1. In both groups there was a significant decrease of the spirometry values (Forced Vital Capacity and Forced expiratory volume in 1 second) until POD5 (Ppleural drainage in severe Chronic obstructive pulmonary disease patients determined better preservation and recovery of pulmonary capacity and volumes with lower pulmonary shunt fraction and better clinical outcomes on early postoperative off-pump coronary artery bypass grafting.

  3. Automated Weaning from Mechanical Ventilation after Off-Pump Coronary Artery Bypass Grafting.

    Science.gov (United States)

    Fot, Evgenia V; Izotova, Natalia N; Yudina, Angelika S; Smetkin, Aleksei A; Kuzkov, Vsevolod V; Kirov, Mikhail Y

    2017-01-01

    The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning ( n  = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning ( n  = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO 2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group ( p  ventilation in a more protective way, reduces the

  4. Effect of using pump on postoperative pleural effusion in the patients that underwent CABG

    Directory of Open Access Journals (Sweden)

    Mehmet Özülkü

    2015-08-01

    Full Text Available Abstract Objective: The present study investigated effect of using pump on postoperative pleural effusion in patients who underwent coronary artery bypass grafting. Methods: A total of 256 patients who underwent isolated coronary artery bypass grafting surgery in the Cardiovascular Surgery clinic were enrolled in the study. Jostra-Cobe (Model 043213 105, VLC 865, Sweden heart-lung machine was used in on-pump coronary artery bypass grafting. Off-pump coronary artery bypass grafting was performed using Octopus and Starfish. Proximal anastomoses to the aorta in both on-pump and off-pump techniques were performed by side clamps. The patients were discharged from the hospital between postoperative day 6 and day 11. Results: The incidence of postoperative right pleural effusion and bilateral pleural effusion was found to be higher as a count in Group 1 (on-pump as compared to Group 2 (off-pump. But the difference was not statistically significant [P>0.05 for right pleural effusion (P=0.893, P>0.05 for bilateral pleural effusion (P=0.780]. Left pleural effusion was encountered to be lower in Group 2 (off-pump. The difference was found to be statistically significant (P<0.05, P=0.006. Conclusion: Under the light of these results, it can be said that left pleural effusion is less prevalent in the patients that underwent off-pump coronary artery bypass grafting when compared to the patients that underwent on-pump coronary artery bypass grafting.

  5. Sub-xyphoid pleural drain as a determinant of functional capacity and clinical results after off-pump coronary artery bypass surgery: a randomized clinical trial.

    Science.gov (United States)

    Guizilini, Solange; Alves, Daniel F; Bolzan, Douglas W; Cancio, Andreia S A; Regenga, Marisa M; Moreira, Rita S L; Trimer, Renata; Gomes, Walter J

    2014-09-01

    The aim of this trial was to compare functional capacity, pulmonary shunt fraction and clinical outcomes between patients undergoing pleurotomy with a pleural drain inserted in the sub-xyphoid position and patients with a pleural drain placed in the intercostal position after off-pump coronary artery bypass surgery. Patients were randomized into two groups according to the pleural drain site: Group II (n = 33 intercostal pleural drain); and Group SI (n = 35 sub-xyphoid pleural drain). Functional capacity was assessed by the distance covered on the 6-min walking test performed preoperatively and on postoperative day (POD) 5; in addition, pulmonary function test was determined preoperatively and on POD 1 and 5. Pulmonary shunt fraction was evaluated preoperatively and on POD 1, and clinical outcomes were recorded throughout the study. Group SI had better preservation of lung volumes and capacities in POD compared with Group II (P Pulmonary shunt fraction increased in both groups postoperatively; however, Group SI showed a smaller pulmonary shunt fraction (0.26 ± 0.04 vs 0.21 ± 0.04%; P = 0.0014). Functional capacity was significantly reduced in both groups on POD 5; however, Group SI showed better preservation of functional capacity (P = 0.0001). Group SI had better postoperative clinical results, with lower incidence of atelectasis and pleural effusion (P capacity and exercise tolerance with a smaller pulmonary shunt fraction and improved clinical outcomes compared with intercostal pleural drainage after off-pump coronary artery bypass surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  6. Effect of clopidogrel premedication in off-pump cardiac surgery: are we forfeiting the benefits of reduced hemorrhagic sequelae?

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Medlam, Diego A; Petro, Kathleen R; Haile, Elizabeth; Hill, Peter C; Dullum, Mercedes K C; Bafi, Ammar S; Boyce, Steven W; Corso, Paul J

    2006-04-04

    Premedication with clopidogrel has reduced thrombotic complications after percutaneous coronary revascularization procedures. However, because of the enhanced and irreversible platelet inhibition by clopidogrel, patients requiring surgical revascularization have a higher risk of bleeding complications and transfusion requirements. A principal benefit of surgical coronary revascularization without cardiopulmonary bypass is its lower hemorrhagic sequelae. The purpose of this study was to evaluate the effect of preoperative clopidogrel administration in the incidence of hemostatic reexploration, blood product transfusion rates, morbidity, and mortality in patients undergoing off-pump coronary artery bypass graft surgery using a large patient sample and a risk-adjusted approach. Two hundred eighty-one patients (17.9%) did and 1291 (82.1%) did not receive clopidogrel before their surgery, for a total of 1572 patients undergoing isolated off-pump coronary artery bypass graft surgery between January 2000 and June 2002. Risk-adjusted logistic regression analyses and a matched pair analyses by propensity scores were used to assess the association between clopidogrel administration and reoperation as a result of bleeding, intraoperative and postoperative blood transfusions received, and the need for multiple transfusions. Hemorrhage-related preoperative risk factors identified in the literature and those found significant in a univariate model were used. The clopidogrel group had a higher likelihood of hemostatic reoperations (odds ratio [OR], 5.1; 95% confidence interval [CI], 2.47 to 10.47; P<0.01) and an increased need in overall packed red blood cell (OR, 2.6; 95% CI, 1.94 to 3.60; P<0.01), multiple unit (OR, 1.6; 95% CI, 1.07 to 2.48; P=0.02), and platelet (OR, 2.5; 95% CI, 1.77 to 3.66; P<0.01) transfusions. Surgical outcomes and operative mortality (1.4% versus 1.4%; P=1.00) were not statistically different. Clopidogrel administration in the cardiology suite increases

  7. Pleural subxyphoid drain confers better pulmonary function and clinical outcomes in chronic obstructive pulmonary disease after off-pump coronary artery bypass grafting: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Solange Guizilini

    2014-12-01

    Full Text Available Objective: To evaluate the lung function and clinical outcome in severe chronic obstructive pulmonary disease in patients undergoing off-pump coronary artery bypass grafting with left internal thoracic artery graft, comparing the pleural drain insertion in the intercostal versus subxyphoid region. Methods: A randomized controlled trial. Chronic obstructive pulmonary disease patients were randomized into two groups according pleural drain site: II group (n=27 - pleural drain in intercostal space; SI group (n=29 - pleural drain in the subxyphoid region. Spirometry values (Forced Vital Capacity - and Forced expiratory volume in 1 second were obtained on preoperative and 1, 3 and 5 postoperative days. Chest x-ray from preoperative until postoperative day 5 (POD5 was performed for monitoring respiratory events, such as atelectasis and pleural effusion. Pulmonary shunt fraction and pain score was evaluate preoperatively and on postoperative day 1. Results: In both groups there was a significant decrease of the spirometry values (Forced Vital Capacity and Forced expiratory volume in 1 second until POD5 (P<0.05. However, when compared, SI group presented less decrease in these parameters (P<0.05. Pulmonary shunt fraction was significantly lower in SI group (P<0.05. Respiratory events, pain score, orotracheal intubation time and postoperative length of hospital stay were lower in the SI group (P<0.05. Conclusion: Subxyphoid pleural drainage in severe Chronic obstructive pulmonary disease patients determined better preservation and recovery of pulmonary capacity and volumes with lower pulmonary shunt fraction and better clinical outcomes on early postoperative off-pump coronary artery bypass grafting.

  8. Estudo comparativo entre cirurgia de revascularização miocárdica com e sem circulação extracorpórea em mulheres Comparative study between on-pump and off-pump coronary artery bypass graft in women

    Directory of Open Access Journals (Sweden)

    Michel Pompeu Barros de Oliveira Sá

    2010-06-01

    Full Text Available INTRODUÇÃO: Tem sido bem documentado que mulheres têm taxas de morbimortalidade mais altas que homens submetidos à cirurgia de revascularização miocárdica (CRM. Em vista desta evidência, é necessário saber se há benefício da CRM sem circulação extracorpórea (CEC em comparação à CRM com CEC. OBJETIVOS: Comparar desfechos de morbimortalidade entre CRM sem CEC e CRM com CEC. MÉTODOS: Estudo retrospectivo. Nossa investigação analisa comparativamente o perfil clínico, 13 complicações relativas ao procedimento e mortalidade de uma população de 941 mulheres submetidas à CRM (549 sem CEC e 392 com CEC em dois hospitais, no período de janeiro de 2000 a dezembro de 2005. RESULTADOS: A taxa de mortalidade em mulheres submetidas à CRM sem CEC é menor que mulheres submetidas à CRM com CEC, entretanto, a diferença não é estatisticamente significativa (3,1% vs. 5,3%; P=0,134. As taxas de complicações analisadas (choque hemorrágico, neurológicas, respiratórias, insuficiência renal aguda, síndrome da angústia respiratória do adulto, septicemia, pneumonia, fibrilação atrial foram menores (diferença estatisticamente significativa em mulheres do grupo CRM sem CEC em comparação ao grupo CRM com CEC, com exceção das complicações baixo débito cardíaco e infecção de ferida operatória. CONCLUSÕES: As evidências sugerem que CRM sem CEC pode beneficiar as mulheres em comparação com CRM com CEC, pois parece reduzir as taxas de morbimortalidade. Dez das 13 complicações investigadas demonstraram uma significativa vantagem das mulheres submetidas à CRM sem CEC em relação àquelas submetidas à CRM com CEC.BACKGROUND: It has been well documented that women have higher morbidity and mortality rates than men following coronary artery bypass graft (CABG surgery. In view of this evidence, it is necessary to know if there is benefit to off-pump CABG surgery in women in comparison to on-pump CABG. OBJECTIVES: Compare

  9. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    Science.gov (United States)

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  10. Relationship between Angiotensin Converting Enzyme, Apelin, and New-Onset Atrial Fibrillation after Off-Pump Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Shu Xu

    2017-01-01

    Full Text Available It has been shown that inflammation and oxidative stress are important factors in postoperative atrial fibrillation (POAF. Angiotensin converting enzyme (ACE and apelin have a close relationship with inflammation and oxidative stress. The effect of ACE and apelin on POAF after off-pump coronary artery bypass grafting (OPCABG remains a question. The concentrations of serum ACE, angiotensin II (Ang II, apelin, bradykinin (BK, malondialdehyde (MDA, and C reactive protein (CRP were measured in the perioperative period of OPCABG. The levels of serum ACE in the POAF group were higher than in the no POAF group both preoperatively and postoperatively. Apelin in the POAF group was lower than in the no POAF group. There was a correlation between serum ACE and apelin. Postoperatively, CRP and MDA in the POAF group were higher than in the no POAF group; however, there was no difference before the operation. Preoperative ACE and apelin were both significant and independent risk factors for POAF. In conclusion, the high ACE and low apelin preoperatively led to CRP and MDA being increased postoperatively, which was probably associated with POAF after OPCABG. Apelin may be a new predictor for POAF.

  11. Open-Lung Ventilation Improves Clinical Outcomes in Off-Pump Coronary Artery Bypass Surgery: A Randomized Controlled Trial.

    Science.gov (United States)

    Bolzan, Douglas W; Trimer, Renata; Begot, Isis; Nasrala, Mara L S; Forestieri, Patricia; Mendez, Vanessa M F; Arena, Ross; Gomes, Walter J; Guizilini, Solange

    2016-06-01

    To compare pulmonary function, functional capacity, and clinical outcomes among conventional mechanical ventilation (CMV), early open-lung (EOL), and late open-lung (LOL) strategies after off-pump coronary artery bypass surgery (OPCAB). Prospective, randomized, and double-blinded study. Two hospitals of the Federal University of Sao Paulo, Brazil. Ninety-three patients undergoing elective first-time OPCAB. Patients were randomized into 3 groups: CMV (n=31); LOL (n=32) initiated upon intensive care unit (ICU) arrival; EOL (n = 30) initiated after intubation. Spirometry was performed at bedside preoperatively and on postoperative days (PODs) 1, 3, and 5. Partial pressure of arterial oxygen (PaO2) and pulmonary shunt fraction were evaluated presurgically and on POD 1; 6-minute walk test (6MWT) was performed presurgically and on POD 5. Both open-lung groups demonstrated higher forced vital capacity and forced expiratory volume in 1 second on PODs 1, 3 and 5 compared to the CMV group (pLOL groups were compared. Both open-lung strategies were able to promote higher pulmonary function preservation and greater recovery of functional capacity with better clinical outcomes after OPCAB. No difference in outcome was found when comparing initiation of OLS intraoperatively or after ICU arrival. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Sequential Vein Bypass Grafting is Not Associated with an Increase of Either In-hospital or Mid-term Adverse Events in Off-pump Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Fucheng Xiao

    2015-01-01

    Full Text Available Background: The impact of sequential vein bypass grafting on clinical outcomes is less known in off-pump coronary artery bypass grafting (CABG. We aimed to evaluate the effects of sequential vein bypass grafting on clinical outcomes in off-pump CABG. Methods: From October 2009 to September 2013 at the Fuwai Hospital, 127 patients with at least one sequential venous graft were matched with 127 patients of individual venous grafts only, using propensity score matching method to obtain risk-adjusted outcome comparison. In-hospital measurement was composite outcome of in-hospital death, myocardial infarction (MI, stroke, requirement for intra-aortic ballon pump (IABP assistance and prolonged ventilation. Major adverse cardiac events (MACEs: Death, MI or repeat revascularization and angina recurrence were considered as mid-term endpoints. Results: No significant difference was observed among the groups in baseline characteristics. Intraoperative mean blood flow per vein graft was 40.4 ml in individual venous grafts groups versus 59.5 ml in sequential venous grafts groups (P < 0.001. There were no differences between individual and sequential venous grafts groups with regard to composite outcome of in-hospital mortality, MI, stroke, IABP assistance and prolonged ventilation (11.0% vs. 14.2%, P = 0.45. Individual in-hospital measurement also did not differ significantly between the two groups. At about four years follow-up, the survival estimates free from MACEs (92.5% vs. 97.3%, P = 0.36 and survival rates free of angina recurrence (80.9% vs. 85.5%, P = 0.48 were similar among individual and sequential venous grafts groups with a mean follow-up of 22.5 months. In the Cox regression analysis, sequential vein bypass grafting was not identified as an independent predictor of both MACEs and angina recurrence. Conclusions: Compared to individual vein bypass grafting, sequential vein bypass grafting was not associated with an increase of either in

  13. Análise dos resultados imediatos da cirurgia de revascularização do miocárdio com e sem circulação extracorpórea Analysis of immediate results of on-pump versus off-pump coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Marcos Antonio Cantero

    2012-03-01

    Full Text Available OBJETIVO: Comparar os resultados imediatos da cirurgia de revascularização do miocárdio com e sem circulação extracorpórea (CEC. MÉTODOS: De janeiro de 2007 a janeiro de 2009, 177 pacientes foram submetidos a cirurgia de revascularização do miocárdio (CRM, sendo 92, sem CEC e 85 com CEC. Foram avaliados distribuição demográfica, fatores de risco pré-operatórios, classe funcional e avaliação de risco pelo EuroSCORE. A evolução no pós-operatório foi comparada entre os grupos. RESULTADOS: A média de enxertos por paciente foi de 2,48 ± 0,43, no grupo sem CEC, e 2,90 ± 0,59, no com CEC. No grupo sem CEC, 97,8% dos pacientes receberam um enxerto de artéria torácica interna, enquanto que no grupo com CEC a porcentagem foi de 94,1% (P = 0,03. A taxa de revascularização completa foi similar em ambos os grupos. No grupo sem CEC, a artéria circunflexa foi revascularizada em 48,9% dos casos e, em 68,2%, no grupo com CEC (P = 0,01. A mortalidade hospitalar foi de 4,3% e 4,7%, respectivamente, no grupo sem CEC e com CEC (P = 0,92. Os pacientes operados sem CEC apresentaram menor índice de complicações em relação ao infarto perioperatório (P= 0,02 e ao uso de balão intra-aórtico (P= 0,01. CONCLUSÃO: A cirurgia coronariana sem CEC é um procedimento seguro, com mortalidade hospitalar similar a dos pacientes operados com CEC, com menores taxas de complicações e de incidência de infarto perioperatório, bem como menor necessidade de balão intra-aórtico.OBJECTIVE: The objective of this study is to compare the immediate results of patients undergoing on-pump versus off-pump coronary artery bypass graft (CABG surgery. METHODS: From January 2007 to January 2009, 177 patients underwent CABG, being 92 off-pump and 85 onpump. We evaluated the demographics, preoperative risk factors, preoperative functional class and risk assessment by the EuroSCORE. The postoperative evolution was compared between groups. RESULTS: The mean

  14. Effect of milrinone on short term outcome of patients with myocardial dysfunction undergoing off-pump coronary artery bypass graft: a randomized clinical trial.

    Science.gov (United States)

    Hadadzadeh, Mehdi; Hosseini, Seyed Habib; Mostafavi Pour Manshadi, Seyed Mohammad Yousof; Naderi, Nafiseh; Emami Meybodi, Mahmood

    2013-01-01

    Myocardial dysfunction is a major complication in cardiac surgery that needs inotropic support. This study evaluates the effect of milrinone on patients with low ventricular ejection fraction undergoing off- pump coronary artery bypass graft (OPCAB). The present study is designed to evaluate the effect of milrinone on myocardial dysfunction. Eighty patients with low ventricular ejection fraction (milrinone (50 μg/kg) intravenously and another group received a saline as placebo followed by 24 hours infusion of each agent (0.5 μg/kg/min). Short outcome of patients such as hemodynamic parameters and left ventricular ejection fraction were variables evaluated. Serum levels of creatine phosphokinase, the MB isoenzyme of creatine kinase, occurrence of arrhythmias and mean duration of mechanical ventilation were significantly lower in milrinone group (P<0.05). The mean post operative left ventricular ejection fraction was significantly higher in milrinone group (P=0.031). There were no statistical significant differences between the two groups in terms of intra-aortic balloon pump, inotropic support requirement, myocardial ischemia, myocardial infarction, duration of inotropic support, duration of intensive care unit stay, mortality and morbidity rate. Administration of milrinone in patients undergoing OPCAB with low ventricular ejection fraction is useful and effective.

  15. Effect of preoperatively continued aspirin use on early and mid-term outcomes in off-pump coronary bypass surgery: a propensity score-matched study of 1418 patients.

    Directory of Open Access Journals (Sweden)

    Fucheng Xiao

    Full Text Available To date, effect of preoperatively continued aspirin administration in off-pump coronary artery bypass grafting (CABG is less known. We aimed to assess the effect of preoperatively continued aspirin use on early and mid-term outcomes in patients receiving off-pump CABG.From October 2009 to September 2013 at the Fuwai Hospital, 709 preoperative aspirin users were matched with unique 709 nonaspirin users using propensity score matching to obtain risk-adjusted outcome comparisons between the two groups. Early outcomes were in-hospital death, stroke, intra- and post-operative blood loss, reoperation for bleeding and blood product transfusion. Major adverse cardiac events (death, myocardial infarction or repeat revascularization, angina recurrence and cardiogenic readmission were considered as mid-term endpoints.There were no significant differences among the groups in baseline characteristics after propensity score matching. The median intraoperative blood loss (600 ml versus 450 ml, P = 0.56, median postoperative blood loss (800 ml versus 790 ml, P = 0.60, blood transfusion requirements (25.1% versus 24.4%, P = 0.76 and composite outcome of in-hospital death, stroke and reoperation for bleeding (2.8% versus 1.6%, P = 0.10 were similar in aspirin and nonaspirin use group. At about 4 years follow-up, no significant difference was observed among the aspirin and nonaspirin use group in major adverse cardiac events free survival estimates (95.7% versus 91.5%, P = 0.23 and freedom from cardiogenic readmission (88.5% versus 85.3%, P = 0.77 whereas the angina recurrence free survival rates was 83.7% and 73.9% in the aspirin and nonaspirin use group respectively (P = 0.02, with odd ratio for preoperative aspirin estimated at 0.71 (95% confidence interval, 0.49-1.04, P = 0.08.Preoperatively continued aspirin use was not associated with increased risk of intra- and post-operative blood loss, blood transfusion requirements and composite outcome of in

  16. Sevoflurane causes less arrhythmias than desflurane after off-pump coronary artery bypass grafting: A pilot study

    Directory of Open Access Journals (Sweden)

    Hemmerling Thomas

    2010-01-01

    Full Text Available Background: Volatile anesthetics provide myocardial protection during cardiac surgery. Sevoflurane and desflurane are both efficient agents that allow immediate extubation after off-pump coronary artery bypass grafting (OPCABG. This study compared the incidence of arrhythmias after OPCABG with the two agents. Materials and Methods: Forty patients undergoing OPCABG with immediate extubation and perioperative high thoracic analgesia were included in this controlled, double-blind study; anesthesia was either provided using 1 MAC of sevoflurane (SEVO-group or desflurane (DES-group. Monitoring of perioperative arrhythmias was provided by continuous monitoring of the EKG up to 72 hours after surgery, and routine EKG monitoring once every day, until time of discharge. Patient data, perioperative arrhythmias, and myocardial protection (troponin I, CK, CK-MB-ratio, and transesophageal echocardiography examinations were compared using t-test, Fisher′s exact test or two-way analysis of variance for repeated measurements; P < 0.05. Results: Patient data and surgery-related data were similar between the two groups; all the patients were successfully extubated immediately after surgery, with similar emergence times. Supraventricular tachycardia occurred only in the DES-group (5 of 20 patients, atrial fibrillation was significantly more frequent in the DES group versus SEVO-group, at five out of 20 versus one out of 20 patients, respectively. Myocardial protection was equally achieved in both groups. Discussion: Ultra-fast track anesthesia using sevoflurane seems more advantageous than desflurane for anesthesia, for OPCABG, as it is associated with significantly less atrial fibrillation or supraventricular arrhythmias after surgery.

  17. Effect of milrinone on short term outcome of patients with myocardial dysfunction undergoing off-pump coronary artery bypass graft: a randomized clinical trial.

    Directory of Open Access Journals (Sweden)

    Mehdi Hadadzadeh

    2013-10-01

    Full Text Available Myocardial dysfunction is a major complication in cardiac surgery that needs inotropic support. This study evaluates the effect of milrinone on patients with low ventricular ejection fraction undergoing off- pump coronary artery bypass graft (OPCAB. The present study is designed to evaluate the effect of milrinone on myocardial dysfunction. Eighty patients with low ventricular ejection fraction (<35%, candidate for elective OPCAB, were enrolled in this study. They were randomly assigned to two groups. One group received milrinone (50 μg/kg intravenously and another group received a saline as placebo followed by 24 hours infusion of each agent (0.5 μg/kg/min. Short outcome of patients such as hemodynamic parameters and left ventricular ejection fraction were variables evaluated. Serum levels of creatine phosphokinase, the MB isoenzyme of creatine kinase, occurrence of arrhythmias and mean duration of mechanical ventilation were significantly lower in milrinone group (P<0.05. The mean post operative left ventricular ejection fraction was significantly higher in milrinone group (P=0.031. There were no statistical significant differences between the two groups in terms of intra-aortic balloon pump, inotropic support requirement, myocardial ischemia, myocardial infarction, duration of inotropic support, duration of intensive care unit stay, mortality and morbidity rate. Administration of milrinone in patients undergoing OPCAB with low ventricular ejection fraction is useful and effective.

  18. Renal Dysfunction after Off-Pump Coronary Artery Bypass Surgery- Risk Factors and Preventive Strategies

    Directory of Open Access Journals (Sweden)

    Gaurab Maitra

    2009-01-01

    Full Text Available Postoperative renal dysfunction is a relatively common and one of the serious complications of cardiac surgery. Though off-pump coronary artery bypass surgery technique avoids cardiopulmonary bypass circuit induced adverse effects on renal function, multiple other factors cause postoperative renal dysfunction in these groups of patients. Acute kidney injury is generally defined as an abrupt and sustained decrease in kidney function. There is no consen-sus on the amount of dysfunction that defines acute kidney injury, with more than 30 definitions in use in the literature today. Although serum creatinine is widely used as a marker for changes in glomerular filtration rate, the criteria used to define renal dysfunction and acute renal failure is highly variable. The variety of definitions used in clinical studies may be partly responsible for the large variations in the reported incidence. Indeed, the lack of a uniform definition for acute kidney injury is believed to be a major impediment to research in the field. To establish a uniform definition for acute kidney injury, the Acute Dialysis Quality Initiative formulated the Risk, Injury, Failure, Loss, and End-stage Kidney (RIFLE classification. RIFLE , defines three grades of increasing severity of acute kidney injury -risk (class R, injury (class I and failure (class F - and two outcome classes (loss and end-stage kidney disease. Various perioperative risk factors for postoperative renal dysfunction and failure have been identified. Among the important preoperative factors are advanced age, reduced left ventricular function, emergency surgery, preoperative use of intraaortic balloon pump, elevated preoperative serum glucose and creatinine. Most important intraoperative risk factor is the intraoperative haemodynamic instability and all the causes of postoperative low output syndrome com-prise the postoperative risk factors. The most important preventive strategies are the identification of the

  19. Right pleural versus mediastinal drainage following elective off-pump coronary artery bypass

    Directory of Open Access Journals (Sweden)

    Forouzan nia SKh

    2011-03-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Proper drainage of the mediastinal and pleural spaces following Off-Pump Coronary Artery Bypass (OPCAB surgery is essential for the prevention of pleural and pericardial effusions, cardiac tamponade and late complications such as constrictive pericarditis. Drainage tubes themselves may induce some complications which can negatively affect the result of the surgery. In this study we assessed a new technique for chest drainage following OPCAB."n"nMethods: In this clinical trial, 171 patients were allocated to two groups. In the control group, the drainage technique included one drain in the left pleural cavity and another in the mediastinum, while in the case group; the drainage technique included one drain in the left plural and one in the right pleural cavity."n"nResults: The amount of drainage in the case group was more than the control group (p=0.001. We found significant reductions in the incidence of arrhythmias in the case group (p=0.005. While one patient (1.2% needed reoperation for bleeding control in the control group, no patients needed reexploration in the case group (p=0.497. The duration of hospital (p=0.022 and ICU (p=0.002 stays was shorter in the case group."n"nConclusions: Based on the

  20. Scrape-off profiles and effects of limiter pumping in Tore Supra

    International Nuclear Information System (INIS)

    Budny, R.

    1986-11-01

    A one dimensional plasma scrape-off model was used to simulate Tore Supra discharges which are limited by various combinations of the pumped and inner limiters. Scrape-off profiles of the electron density and temperature, ion temperature, and neutral density are given. For each case, various fractions of the ion flux to the neutralizers were assumed to be pumped. Modifications of the scrap-off profiles caused by pumping are predicted. Pumping efficiencies are calculated including the effects of flux amplification caused by recycling. The pumping efficiency is estimated to be 8% for low-power discharges formed on the outer pumped limiter, 7.5% for intermediate-power discharges formed on the seven-module pumped-limiter system, and 5% for full-power discharges formed on both the inner limiter and the pumped-limiter system. The maximum particle removal rate is estimated to be 150 Tl/s

  1. Impact of surgeon experience on the rate of blood transfusion in off-pump coronary artery bypass.

    Science.gov (United States)

    Chen, Jeng-Wei; Hsu, Ron-Bin

    2016-03-01

    Off-pump coronary artery bypass (OPCAB) reduces the rate of blood transfusion. No studies have focused on the effect of surgeon experience on the transfusion rate. We sought to assess the transfusion rate in OPCAB and to evaluate the effect of surgeon experience. Retrospective review of 1055 consecutive patients undergoing OPCAB between 2000 and 2012. Patients were divided into tripartites by the year of operation (2000-2004, 2005-2008, and 2009-2012). Surgeon experience was evaluated with revascularization index and conversion rate. Mode of intervention was elective in 768, urgency in 185, and emergency in 102 patients (10%). Blood transfusion was associated with increased rates of hospital mortality and sternal wound/bloodstream infections. Revascularization index was 1.22 ± 0.29 per patient and increased over time, from 1.05 ± 0.21 in 2000-2004 to 1.39 ± 0.26 in 2009-2012. Conversion rate was 10% and decreased over time, from 17% in 2000-2004 to 6% in 2009-2012. The average rate of blood transfusion was 58% and decreased over time, from 74% in 2000-2004 to 41% in 2009-2012. Rate of red blood cell transfusion was 56% and decreased from 72% in 2000-2004 to 40% in 2009-2012. Rate of platelet transfusion was 21% and decreased from 25% in 2000-2004 to 15% in 2009-2012.The most significant decrease in the transfusion rate was observed in nonemergency cases. Surgeon experience reduced the need of blood transfusion after OPCAB. Increasing surgeon experience was associated with a 33% reduction in blood transfusion rate. Copyright © 2015. Published by Elsevier B.V.

  2. Weaning mechanical ventilation after off-pump coronary artery bypass graft procedures directed by noninvasive gas measurements.

    Science.gov (United States)

    Chakravarthy, Murali; Narayan, Sandeep; Govindarajan, Raghav; Jawali, Vivek; Rajeev, Subramanyam

    2010-06-01

    Partial pressure of carbon dioxide and oxygen were transcutaneously measured in adults after off-pump coronary artery bypass (OPCAB) surgery. The clinical use of such measurements and interchangeability with arterial blood gas measurements for weaning patients from postoperative mechanical ventilation were assessed. This was a prospective observational study. Tertiary referral heart hospital. Postoperative OPCAB surgical patients. Transcutaneous oxygen and carbon dioxide measurements. In this prospective observational study, 32 consecutive adult patients in a tertiary care medical center underwent OPCAB surgery. Noninvasive measurement of respiratory gases was performed during the postoperative period and compared with arterial blood gases. The investigator was blinded to the reports of arterial blood gas studies and weaned patients using a "weaning protocol" based on transcutaneous gas measurement. The number of patients successfully weaned based on transcutaneous measurements and the number of times the weaning process was held up were noted. A total of 212 samples (pairs of arterial and transcutaneous values of oxygen and carbon dioxide) were obtained from 32 patients. Bland-Altman plots and mountain plots were used to analyze the interchangeability of the data. Twenty-five (79%) of the patients were weaned from the ventilator based on transcutaneous gas measurements alone. Transcutaneous carbon dioxide measurements were found to be interchangeable with arterial carbon dioxide during 96% of measurements, versus 79% for oxygen measurements. More than three fourths of the patients were weaned from mechanical ventilation and extubated based on transcutaneous gas values alone after OPCAB surgery. The noninvasive transcutaneous carbon dioxide measurement can be used as a surrogate for arterial carbon dioxide measurement to manage postoperative OPCAB patients. Copyright 2010 Elsevier Inc. All rights reserved.

  3. Outcomes of On-pump Coronary Artery Bypass Grafting in Patients with Metabolic Syndrome in Mashhad, Iran

    Directory of Open Access Journals (Sweden)

    Aliasghar Moeinipour

    2017-09-01

    Full Text Available Introduction: Metabolic syndrome (MS is considered as an important risk factor for advanced coronary artery disease. This condition can increase the mortality and morbidity in the patients undergoing coronary artery bypass graft (CABG surgery. The aim of the study was compared mortality and morbidity after off Pump- CABG surgery between patients with and without the Metabolic syndrome. Materials & Methods: This prospective cross-sectional study was conducted on 120 patients, who underwent off-pump CABG surgery between October 2014-October 2016. The participants were equally divided into two groups including the patients with and without MS (MS and non-MS, respectively. Results: According to the results, 68 (56.6% patients were male. Furthermore, out of the 60 participants with MS, 36 (60% cases were male. The mean ages of the MS and non-MS groups were 64.96±9.6 and 65.62±10.6 P=0.6 years, respectively. No statistically significant difference was observed between the two groups in terms of the mortality and morbidity (e.g., surgical wound infection, length of Intensive Care Unit and hospital stay, atrial fibrillation rhythm, and bleeding in the first 24 h. The intubation time in patients with Metabolic Syndrome was significantly higher than patients without Metabolic Syndrome (6.66 ± 1.97 vs 5.83 ± 1.93 respectively; P=0.007 Conclusion: Metabolic syndrome was not associated with higher mortality and morbidity after CABG surgery compare to patients without Metabolic syndrome, although patients with Metabolic syndrome had higher risk for long intubation time.

  4. Preoperative factors affecting cost and length of stay for isolated off-pump coronary artery bypass grafting: hierarchical linear model analysis.

    Science.gov (United States)

    Shinjo, Daisuke; Fushimi, Kiyohide

    2015-11-17

    To determine the effect of preoperative patient and hospital factors on resource use, cost and length of stay (LOS) among patients undergoing off-pump coronary artery bypass grafting (OPCAB). Observational retrospective study. Data from the Japanese Administrative Database. Patients who underwent isolated, elective OPCAB between April 2011 and March 2012. The primary outcomes of this study were inpatient cost and LOS associated with OPCAB. A two-level hierarchical linear model was used to examine the effects of patient and hospital characteristics on inpatient costs and LOS. The independent variables were patient and hospital factors. We identified 2491 patients who underwent OPCAB at 268 hospitals. The mean cost of OPCAB was $40 665 ±7774, and the mean LOS was 23.4±8.2 days. The study found that select patient factors and certain comorbidities were associated with a high cost and long LOS. A high hospital OPCAB volume was associated with a low cost (-6.6%; p=0.024) as well as a short LOS (-17.6%, pcost and LOS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. Effect of Exogenous Albumin on the Incidence of Postoperative Acute Kidney Injury in Patients Undergoing Off-pump Coronary Artery Bypass Surgery with a Preoperative Albumin Level of Less Than 4.0 g/dl.

    Science.gov (United States)

    Lee, Eun-Ho; Kim, Wook-Jong; Kim, Ji-Yeon; Chin, Ji-Hyun; Choi, Dae-Kee; Sim, Ji-Yeon; Choo, Suk-Jung; Chung, Cheol-Hyun; Lee, Jae-Won; Choi, In-Cheol

    2016-05-01

    Hypoalbuminemia may increase the risk of acute kidney injury (AKI). The authors investigated whether the immediate preoperative administration of 20% albumin solution affects the incidence of AKI after off-pump coronary artery bypass surgery. In this prospective, single-center, randomized, parallel-arm double-blind trial, 220 patients with preoperative serum albumin levels less than 4.0 g/dl were administered 100, 200, or 300 ml of 20% human albumin according to the preoperative serum albumin level (3.5 to 3.9, 3.0 to 3.4, or less than 3.0 g/dl, respectively) or with an equal volume of saline before surgery. The primary outcome measure was AKI incidence after surgery. Postoperative AKI was defined by maximal AKI Network criteria based on creatinine changes. Patient characteristics and perioperative data except urine output during surgery were similar between the two groups studied, the albumin group and the control group. Urine output (median [interquartile range]) during surgery was higher in the albumin group (550 ml [315 to 980]) than in the control group (370 ml [230 to 670]; P = 0.006). The incidence of postoperative AKI in the albumin group was lower than that in the control group (14 [13.7%] vs. 26 [25.7%]; P = 0.048). There were no significant between-group differences in severe AKI, including renal replacement therapy, 30-day mortality, and other clinical outcomes. There were no significant adverse events. Administration of 20% exogenous albumin immediately before surgery increases urine output during surgery and reduces the risk of AKI after off-pump coronary artery bypass surgery in patients with a preoperative serum albumin level of less than 4.0 g/dl.

  6. Simulation in transient regime of a heat pump with closed-loop and on-off control

    Energy Technology Data Exchange (ETDEWEB)

    Vargas, J.V.C. [Duke Univ., Durham, NC (United States). Dept. of Mechanical Engineering and Materials Science; Parise, J.A.R. [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica

    1995-05-01

    The present work introduces a mathematical model for a heat pump with a variable-speed compressor, driven by a d.c. servomotor, operating either in closed loop by a power law control action or by the traditional on-off basis. The resulting differential and algebraic equations are integrated in time for a specified period of simulation in both designs. The results show that the closed-loop system presents significant savings in energy consumption when compared with the on-off system, under the same environmental conditions. (author)

  7. Qualidade de vida após revascularização cirúrgica do miocárdio com e sem circulação extracorpórea Quality of life after on-pump and off-pump coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Celia R. S. R. Nogueira

    2008-10-01

    Full Text Available FUNDAMENTO: Técnicas de cirurgia de revascularização miocárdica (RM sem o uso de circulação extracorpórea (CEC possibilitou resultados operatórios com menor dano sistêmico, menor ocorrência de complicações clínicas, menor permanência na sala de terapia intensiva e também no tempo de internação, gerando expectativas de melhor qualidade de vida (QV dos pacientes. OBJETIVO: Avaliar a QV em pacientes submetidos à cirurgia de revascularização com e sem CEC. MÉTODOS: Em pacientes com doença multiarterial coronariana (DAC estável e função ventricular preservada, aplicou-se o Short-Form Health Survey (SF-36 Questionnaire antes da cirurgia e depois de 6 e 12 meses. RESULTADOS: Entre janeiro de 2002 e dezembro de 2006, foram randomizados 202 pacientes para cirurgia de RM. As características demográficas clínicas laboratoriais e angiográficas foram semelhantes nos dois grupos. Desses pacientes, 105 foram operados sem CEC e 97 com CEC. Na evolução, 22 pacientes sofreram infarto, 29 relataram angina, um reoperou, 3 tiveram AVC e nenhum morreu. A avaliação da QV mostrou similaridade nos dois grupos em relação ao componente físico e mental. Todavia, encontrou-se significativa melhora da capacidade funcional e percepção do aspecto físico nos pacientes do sexo masculino. Além disso, um expressivo número de pacientes dos dois grupos retornou ao trabalho. CONCLUSÃO: Em todos os pacientes estudados, observaram-se melhora progressiva da qualidade de vida e retorno precoce ao trabalho, independentemente da técnica cirúrgica empregada. Exceto pela melhor percepção da capacidade funcional e do aspecto físico experimentado pelos homens, não houve diferença estatística nos resultados dos demais domínios alcançados pelos dois grupos estudados.BACKGROUND: Coronary artery bypass grafting techniques without using cardiopulmonary bypass (off-pump CABG result in less systemic damage, less clinical complications, less time

  8. HEMOPERFUSION DURING CORONARY ANGIOPLASTY - 1ST EUROPEAN EXPERIENCE WITH A NEW HEMOPERFUSION PUMP

    NARCIS (Netherlands)

    DEMUINCK, ED; MEEDER, J; MAGIELSE, C; BOM, VJJ; VANDIJK, RB; VERKERKE, GJ; LIE, KI

    Hemolysis tests with fresh human blood were performed in vitro with a new 5 ml, piston-type hemoperfusion pump, designed to prevent myocardial ischemia during coronary angioplasty. Despite driving pressures greater than 3 atmospheres, shear stress greater than 200 Pa, turbulent pump flow, and the

  9. Total Arterial Off‑pump Coronary Revascularization with a Bilateral ...

    African Journals Online (AJOL)

    Total Arterial Off‑pump Coronary Revascularization with a Bilateral Internal Mammary Artery Y Graft (208 cases). Jun-Feng Yang, Hong-Chao Zhang1, Cheng-Xiong Gu, Hua Wei. INTRODUCTION. AY graft is a graft formed by the left internal mammary artery (LIMA) connected to the left anterior descending (LAD) artery and ...

  10. Application of a pharmacokinetics-pharmacodynamics approach to the free propofol plasma levels during coronary artery bypass grafting surgery with hypothermic cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Carlos R. Silva-Filho

    2018-02-01

    Full Text Available OBJECTIVES: The objective of this study was to apply a pharmacokinetics-pharmacodynamics approach to investigate the free propofol plasma levels in patients undergoing coronary artery bypass grafting under hypothermic conditions compared with the off-pump procedure. METHODS: Nineteen patients scheduled for on-pump coronary artery bypass grafting under hypothermic conditions (n=10 or the equivalent off-pump surgery (n=9 were anesthetized with sufentanil and propofol target-controlled infusion (2 μg/mL during surgery. The propofol concentration was then reduced to 1 μg/mL, and a pharmacokinetics-pharmacodynamics analysis using the maximum-effect-sigmoid model obtained by plotting the bispectral index values against the free propofol plasma levels was performed. RESULTS: Significant increases (two- to five-fold in the free propofol plasma levels were observed in the patients subjected to coronary artery bypass grafting under hypothermic conditions. The pharmacokinetics of propofol varied according to the free drug levels in the hypothermic on-pump group versus the off-pump group. After hypothermic coronary artery bypass was initiated, the distribution volume increased, and the distribution half-life was prolonged. Propofol target-controlled infusion was discontinued when orotracheal extubation was indicated, and the time to patient extubation was significantly higher in the hypothermic on-pump group than in the off-pump group (459 versus 273 min, p=0.0048. CONCLUSIONS: The orotracheal intubation time was significantly longer in the hypothermic on-pump group than in the off-pump group. Additionally, residual hypnosis was identified through the pharmacokinetics-pharmacodynamics approach based on decreases in drug plasma protein binding in the hypothermic on-pump group, which could explain the increased hypnosis observed with this drug in this group of patients.

  11. Subxyphoid pleural drain confers lesser impairment in respiratory muscle strength, oxygenation and lower chest pain after off-pump coronary artery bypass grafting: a randomized controlled trial.

    Science.gov (United States)

    Cancio, Andreia S A; Guizilini, Solange; Bolzan, Douglas W; Dauar, Renato B; Succi, José E; de Paola, Angelo A V; Carvalho, Antonio C de Camargo; Gomes, Walter J

    2012-01-01

    To evaluate respiratory muscle strength, oxygenation and chest pain in patients undergoing off-pump coronary artery bypass (OPCAB) using internal thoracic artery grafts comparing pleural drain insertion site at the subxyphoid region versus the lateral region. Forty patients were randomized into two groups in accordance with the pleural drain site. Group II (n = 19) -pleural drain exteriorized in the intercostal space; group (SI) (n = 21) chest tube exteriorized at the subxyphoid region. All patients underwent assessment of respiratory muscle strength (inspiratory and expiratory) on the pre, 1, 3 and 5 postoperative days (POD). Arterial blood gas analysis was collected on the pre and POD1. The chest pain sensation was measured 1, 3 and 5 POD. A significant decrease in respiratory muscle strength (inspiratory and expiratory) was seen in both groups until POD5 (P pleural drainage showed less decrease in respiratory muscle strength, better preservation of blood oxygenation and reduced thoracic pain compared to patients with intercostal drain on early OPCAB postoperative.

  12. Effect of thoracic epidural anesthesia on oxygen delivery and utilization in cardiac surgical patients scheduled to undergo off-pump coronary artery bypass surgery: a prospective study.

    Science.gov (United States)

    Suryaprakash, Sharadaprasad; Chakravarthy, Murali; Gautam, Mamatha; Gandhi, Anurag; Jawali, Vivek; Patil, Thimmannagowda; Jayaprakash, Krishnamoorthy; Pandey, Saurabh; Muniraju, Geetha

    2011-01-01

    To evaluate the effect of thoracic epidural anesthesia (TEA) on tissue oxygen delivery and utilization in patients undergoing cardiac surgery. This prospective observational study was conducted in a tertiary referral heart hospital. A total of 25 patients undergoing elective off-pump coronary artery bypass surgery were enrolled in this study. All patients received thoracic epidural catheter in the most prominent inter-vertebral space between C7 and T3 on the day before operation. On the day of surgery, an arterial catheter and Swan Ganz catheter (capable of measuring cardiac index) was inserted. After administering full dose of local anesthetic in the epidural space, serial hemodynamic and oxygen transport parameters were measured for 30 minute prior to administration of general anesthesia, with which the study was culminated. A significant decrease in oxygen delivery index with insignificant changes in oxygen extraction and consumption indices was observed. We conclude that TEA does not affect tissue oxygenation despite a decrease in arterial pressures and cardiac output.

  13. Effect of thoracic epidural anesthesia on oxygen delivery and utilization in cardiac surgical patients scheduled to undergo off-pump coronary artery bypass surgery: A prospective study

    Directory of Open Access Journals (Sweden)

    Suryaprakash Sharadaprasad

    2011-01-01

    Full Text Available To evaluate the effect of thoracic epidural anesthesia (TEA on tissue oxygen delivery and utilization in patients undergoing cardiac surgery. This prospective observational study was conducted in a tertiary referral heart hospital. A total of 25 patients undergoing elective off-pump coronary artery bypass surgery were enrolled in this study. All patients received thoracic epidural catheter in the most prominent inter-vertebral space between C7 and T3 on the day before operation. On the day of surgery, an arterial catheter and Swan Ganz catheter (capable of measuring cardiac index was inserted. After administering full dose of local anesthetic in the epidural space, serial hemodynamic and oxygen transport parameters were measured for 30 minute prior to administration of general anesthesia, with which the study was culminated. A significant decrease in oxygen delivery index with insignificant changes in oxygen extraction and consumption indices was observed. We conclude that TEA does not affect tissue oxygenation despite a decrease in arterial pressures and cardiac output.

  14. Embracing the heart: perioperative management of patients undergoing off-pump coronary artery bypass grafting using the octopus tissue stabilizer.

    Science.gov (United States)

    Nierich, A P; Diephuis, J; Jansen, E W; van Dijk, D; Lahpor, J R; Borst, C; Knape, J T

    1999-04-01

    To describe hemodynamic alterations during coronary artery bypass grafting (CABG) without extracorporeal circulation using the Octopus Tissue Stabilizer, and to describe the two anesthetic management protocols based on either general anesthesia with opioids (34 patients) or general anesthesia with high thoracic epidural anesthesia (TEA; 66 patients). A prospective observational report. An academic university heart center. First 100 patients undergoing CABG using the Octopus Tissue Stabilizer. None. Current management provided satisfactory results in preventing hypoperfusion of the heart and inadequate systemic circulation without the use of major pharmacologic interventions. Movement of the heart to reach the target site of anastomosis caused hemodynamic alterations. These could easily be corrected by anesthetic interventions, such as fluid load and low doses of inotropes. High TEA allows earlier extubation compared with the opioid anesthesia technique (0.9 v 4.5 hours). Perioperative management and the incidence of postoperative complications did not differ between anesthetic techniques. Major complications, such as death, intraoperative myocardial infarction, and stroke, did not occur. Both anesthetic protocols are safe and effective in handling these patients. Off-pump CABG surgery requires anesthetic interventions because hemodynamic alterations are caused by the presentation of the heart to the surgeon. The complication rate is low but needs to be evaluated, compared with conventional CABG, in a prospective randomized study. High thoracic epidural anesthesia allows early recovery, but improved outcome could not be proved in this patient group.

  15. Coronary artery bypass grafting on the beating heart using the Octopus method

    NARCIS (Netherlands)

    Thijssens, K. M.; Rodrigus, I. E.; Amsel, B. J.; de Hert, S. G.; Moulijn, A. C.

    2000-01-01

    STUDY OBJECTIVE: To study the usefulness and effectiveness of off-pump coronary bypass grafting with the Octopus heart stabilizing device. METHOD: The files of thirty-one patients undergoing coronary artery bypass with the aid of the Octopus heart stabilizing device between April 1996 and October

  16. The Effect of Milrinone on the Right Ventriclular Function in Patients with Reduced Right Ventricular Function Undergoing Off-pump Coronary Artery Bypass Graft Surgery

    Science.gov (United States)

    Lee, Jong Hwa; Oh, Young Jun; Shim, Yon Hee; Hong, Yong Woo; Yi, Gijong

    2006-01-01

    This investigation evaluated the effect of continuous milrinone infusion on right ventriclular (RV) function during off-pump coronary artery bypass graft (OPCAB) surgery in patients with reduced RV function. Fifty patients scheduled for OPCAB, with thermodilution RV ejection fraction (RVEF) milrinone (0.5 µg/kg/min) or control (saline) group. Hemodynamic variables and RV volumetric data measured by thermodilution method were collected as follows: after anesthesia induction (T1); 10 min after heart displacement for obtuse marginal artery anastomosis (T2); after pericardial closure (T3). Cardiac index and heart rate increased and systemic vascular resistance significantly decreased in milrinone group at T2. Initially lower RVEF of milrinone group was eventually comparable to control group after milrinone infusion. RVEF did not significantly change at T2 and T3 in both groups. RV end-diastolic volume in milrinone group consistently decreased from the baseline at T2 and T3. Continuous infusion of milrinone without a bolus demonstrated potentially beneficial effect on cardiac output and RV afterload in patients with reduced RV function during OPCAB. However, aggressive augmentation of intravascular volume seems to be necessary to maximize the effect of the milrinone in these patients. PMID:17043419

  17. The management of impending myocardial infarction using coronary artery by-pass grafting and an intra-aortic balloon pump.

    Science.gov (United States)

    Harris, P L; Woollard, K; Bartoli, A; Makey, A R

    1980-01-01

    Of 33 patients with impending myocardial infarction 25 were treated using a combination of coronary artery by-pass grafting and intra-aortic balloon pumping. Eight patients were treated with coronary artery by-pass grafting alone. Twenty-two of the 25 patients who were treated with the combined technique made a full recovery. Three patients sustained definite myocardial infarctions and one of these died. Five of the 8 patients treated by grafting alone suffered infarction and of these 3 died. The value of intra-aortic balloon pumping in combination with coronary artery by-pass grafting in the management of impending myocardial infarction is discussed.

  18. The effects of preemptive pregabalin on attenuation of stress response to endotracheal intubation and opioid- sparing effect in patients undergoing off-pump coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Ayya Syama Sundar

    2012-01-01

    Full Text Available The clinical study was designed to evaluate and compare single preoperative dose of pregabalin to a placebo regarding hemodynamic responses to laryngoscopy and endotracheal intubation, to assess perioperative fentanyl requirement and any side-effects. It was a randomized, double-blind, placebo-controlled, parallel assignment, efficacy study. The study was done at a tertiary university hospital. This study was a comparison between two groups of 30 adult patients scheduled for elective off pump coronary artery bypass surgery. In the control group, the patients were given placebo capsules, and in the pregabalin group, the patients were given pregabalin 150 mg capsule orally 1 h before surgery. The patients were compared for hemodynamic changes before the start of the surgery, after induction, 1, 3, and 5 min after intubation. Additionally, fentanyl requirement during surgery and the first postoperative day was also compared. The present study shows that a single oral dose of 150 mg pregabalin given 1 h before surgery attenuated the pressor response to tracheal intubation in adults, but the drug did not show any effect on perioperative opioid consumption and was devoid of side-effects in the given dose.

  19. Revascularização miocárdica por minitoracotomia esquerda: série de casos Left mini-thoracotomy off-pump coronary revascularization

    Directory of Open Access Journals (Sweden)

    Theófilo Gauze

    2007-03-01

    Full Text Available OBJETIVO: A reestenose é uma das complicações freqüentes das angioplastias. Estudos demonstraram superioridade da anastomose de Artéria Torácica Interna Esquerda (ATIE para Coronária Interventricular Anterior (DA. Discute-se a indicação, técnica operatória e resultados da Revascularização do Miocárdio por Minitoracotomia Esquerda (MTE sem extracorpórea. MÉTODO: Foram operados 18 pacientes (três mulheres, idade de 56,6±9,2 anos, com "shunt" intracoronário, para anastomose da ATIE para DA (14 casos ou Diagonal (DI e DA (4 homens. Exposição e estabilização foram obtidas com dispositivo Access (CardioThoracicSystems®. O enxerto foi dissecado esqueletizado e anastomosado com fio único de polipropileno 7-0. RESULTADOS: Não ocorreu óbito, conversão para esternotomia, transfusões ou alterações enzimáticas. As altas hospitalares ocorreram entre 3 e 5 dias e todos os pacientes retomaram suas atividades em até 20 dias. Houve uma reinternação por oclusão do enxerto, tratada com angioplastia, e outra por infecção incisional. Seis pacientes reestudados voluntariamente apresentaram angiografia com enxertos pérvios. CONCLUSÃO: A abordagem mostrou-se segura e sem obstáculos técnicos. Houve tempo de hospitalização curto e baixa morbidade, sem uso de hemoderivados. O instrumental apropriado e, casualmente, a aptidão manual esquerda do cirurgião facilitaram a técnica. Estudos randomizados poderão demonstrar se há benefício econômico e/ou clínico, no longo prazo, desta abordagem como tratamento preferencial.OBJECTIVES: Stent restenosis is a common complication in angioplasty. Studies have shown better outcomes when the left internal thoracic artery (LITA is anastomosed to the left anterior descending artery (LAD. Patient selection, operative technique and results for off-pump left mini-thoracotomy (LME coronary surgery, as a pilot study, are presented. METHODS: Eighteen patients (three women with a mean age of 56

  20. Revascularização miocárdica em pacientes octogenários: estudo retrospectivo e comparativo entre pacientes operados com e sem circulação extracorpórea Myocardial revascularization in octogenarian patients: retrospective and comparative study between patients operated on pump and off pump

    Directory of Open Access Journals (Sweden)

    Ricardo Lima

    2005-03-01

    Full Text Available OBJETIVO: O objetivo do presente trabalho é comparar e analisar os benefícios da cirurgia com e sem CEC, em pacientes octogenários. MÉTODO: Foram analisados dados retrospectivos dos pacientes com 80 anos de idade ou mais, no período de dezembro 1995 a dezembro de 2003. Neste período, 73 pacientes foram submetidos à revascularização do miocárdio (RM, sendo 26 (35,6% com CEC e 47 (64,4%, sem CEC. Os dados demográficos, fatores de risco pré-operatório, comorbidades, classe da angina (CCVS, complicações pós-operatórias e resultados cirúrgicos foram comparados entre os dois grupos (com CEC e sem CEC. Utilizou-se o teste de "t de Student" na comparação entre os grupos e foi considerado um nível de significância de p OBJECTIVE: The purpose of the present study is to compare and analyze the benefits of this operation with and without cardiopulmonary bypass in octogenarian patients. METHOD: Retrospective data of the patients aged eighty years or more from December 1995 to December 2003 were analyzed. During this period 73 patients were submitted to coronary artery bypass grafting (CABG, 26 (35.6% on-pump and 47 (64.4% off-pump. A comparison was made of the demographic data, preoperative risks, concurrent morbid conditions, types of angina, postoperative complications and surgical outcomes between the on-pump and off-pump groups. The Student t-test was used to compare the groups and the level of significance was set at p-value < 0.05. RESULTS: Both groups showed a high preoperative risk, although the off-pump group presented less surgical mortality (11.5% vs 2.1%, p < 0.05. No strokes were observed in the patients operated on off-pump (11.5% vs 0.0%, p < 0.005. Atrial fibrillation (AF in the immediate postoperative period was present less often in the off-pump group (30.8% vs 12.8%, p < 0.005. The postoperative mechanical ventilation time and the presence of respiratory failure were less in the off-pump group (p < 0.005. The presence

  1. Traditional cardiovascular risk factors and coronary collateral circulation: Protocol for a systematic review and meta-analysis of case-control studies.

    Science.gov (United States)

    Xing, Zhenhua; Pei, Junyu; Tang, Liang; Hu, Xinqun

    2018-04-01

    Well-developed coronary collateral circulation usually results in fewer infarct size, improved cardiac function, and fewer mortality. Traditional coronary risk factors (diabetes, hypertension, and smoking) have some effects on coronary collateral circulation. However, the association between these risk factors and coronary collateral circulation are controversial. Given the confusing evidences regarding traditional cardiovascular risk factors on coronary collateral circulation, we performed this meta-analysis protocol to investigate the relationship between traditional risk factors of coronary artery disease and coronary collateral circulation. MEDINE, EMBASE, and Science Citation Index will be searched to identify relevant studies. The primary outcomes of this meta-analysis are well-developed coronary collateral circulation. Meta-analysis was performed to calculate the odds ratio (OR) and 95% confidence interval (CI) of traditional coronary risk factors (diabetes, smoking, hypertriton). Pooled ORs were computed as the Mantel-Haenszel-weighted average of the ORs for all included studies. Sensitivity analysis, quality assessment, publication bias analysis, and the Grading of Recommendations Assessment, Development and Evaluation approach (GRADE) will be performed to ensure the reliability of our results. This study will provide a high-quality synthesis of current evidence of traditional risk factors on collateral circulation. This conclusion of our systematic review and meta-analysis will provide evidence to judge whether traditional risk factors affects coronary collateral circulation.Ethics and dissemination: Ethical approval is not required because our systematic review and meta-analysis will be based on published data without interventions on patients. The findings of this study will be published in a peer-reviewed journal.

  2. Premature Coronary Heart Disease and Traditional Risk Factors-Can We Do Better?

    Directory of Open Access Journals (Sweden)

    Roxana Sadeghi

    2013-06-01

    Full Text Available Background: Traditional cardiovascular risk factors are strong predictors of an increased likelihood for premature CHD. Considering the benefits of risk factors᾿ management, it is imperative to find and treat them before looking for more unknown and weak risk factors. Objectives: Limited information is available about the demographic and historical characteristics of the patients with premature Coronary Heart Disease (CHD in IR Iran. The main objective of this study was to determine the prevalence of the traditional risk factors in these patients. Also, the researchers hypothesized that there are insufficient risk assessment and preventive intervention methods for the asymptomatic adult population. Methods: This study was conducted on 125 patients with premature CHD (age<50 years who were admitted in two academic hospitals with acute coronary syndromes. The patients were accepted since they had a definite CHD on the basis of acute myocardial infarction (elevated cardiac enzymes or documented CAD in coronary angiography. Results: The mean age of the study population was 42.50±5.65 (26 to 49 years. Among the patients,92 (73.6% were male, 113 (90.4% were married, 58 (46.4% were smokers,19 (15.2% were opium users, 97 (77.6% had dyslipidemia, 44 (35.2% had hypertension, and 33 (26.4% had diabetes mellitus. In addition, family history was presented in 54 patients (43.2%. Conclusions: Premature Coronary Heart Disease is a public health problem. However, there is lack of effective and intensive treatments of well-defined traditional risk factors and prevention methods for the majority of the patients experiencing premature CHD. In sum, there is still plenty of room for improvement of risk management in IR Iran.

  3. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms

    Science.gov (United States)

    Szwed, Krzysztof; Pawliszak, Wojciech; Serafin, Zbigniew; Kowalewski, Mariusz; Tomczyk, Remigiusz; Perlinski, Damian; Szwed, Magdalena; Tomaszewska, Marta; Anisimowicz, Lech; Borkowska, Alina

    2017-01-01

    Introduction Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. Methods and analysis In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethics and dissemination Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. Trial registration number NCT03074604; Pre-results. Date and version identifier 10-Mar-2017 Original PMID:28698347

  4. Coronary artery bypass surgery in a patient with Kartagener syndrome: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Bougioukas Ioannis

    2010-08-01

    Full Text Available Abstract Kartagener syndrome consists of congenital bronchiectasis, sinusitis, and total situs inversus in half of the patients. A patient diagnosed with Kartagener syndrome was reffered to our department due to 3-vessel coronary disease. An off-pump coronary artery bypass operation was performed using both internal thoracic arteries and a saphenous vein graft. We performed a literature review for cases with Kartagener syndrome, coronary surgery and dextrocardia. Although a few cases of dextrocardia were found in the literature, no case of Kartagener syndrome was mentioned.

  5. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  6. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft.

    Science.gov (United States)

    Guizilini, Solange; Bolzan, Douglas W; Faresin, Sonia M; Ferraz, Raquel F; Tavolaro, Kelly; Cancio, Andrea A; Gomes, Walter J

    2012-01-25

    Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB) using left internal thoracic artery (LITA). Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position); II (n = 33 intact pleural cavity). Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD) 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5. In both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups. Subxyphoid insertion of pleural drain provides similar effects to

  7. Off-pump coronary surgery: surgical strategy for the high-risk patient.

    Science.gov (United States)

    Van Belleghem, Y; Caes, F; Maene, L; Van Overbeke, H; Moerman, A; Van Nooten, G

    2003-02-01

    In a retrospective study, we compared two groups of consecutive patients operated by the same team during the year 2000 for coronary artery disease with the use of extracorporeal circulation (group 1, n=230) or on the beating heart using the Octopus II plus stabiliser (group 2, n=228). High-risk patients were identified by a EuroSCORE plus 6. EuroSCORE definitions and predicted risk models were utilized to compare the variables of the groups. There were no significant differences between the preoperative variables of the groups in age, gender, left ventricular function, diabetes and peripheral vascular and renal disease as is indicated by the Euroscore (resp. 4.7/5.1 p=0.107). Calcification of the ascending aorta and chronic obstructive lung disease were statistically significant more prevalent in the beating heart group. No differences in preoperative variables in the high-risk patients group (Euroscore 8.5/8.1 p=0.356) except for calcification of the ascending aorta. All patients underwent a full revascularisation through a midline sternotomy. Significant more distal anastomoses were performed in group 1 (3.7 per patient (1-6)) with regard to group 2 (2.9 per patient (1-6)). Anesthesia, postoperative treatment and follow up were equal for both groups. A significant lower incidence of atrial fibrillation (p=0.010), shorter ICU stay (p=0.031) and renal insufficiency (p=0.033) was reported in group 2. In the low risk group, we could not diagnose any difference between the two groups, except for atrial fibrillation. The benefits of the beating heart surgery however were more pronounced in the high-risk patient as is indicated by a significant reduction of the ICU stay by 1 day (3.5d/2.5d (p=0.028)), better preservation of the renal function (p=0.017) and a significant reduction of the length of hospital stay by more than two days (p=0.040). A lower incidence of atrial fibrillation, however not significant. In our experience, beating heart surgery is a safe

  8. Pattern and predictors of dual antiplatelet use after coronary artery bypass graft surgery.

    Science.gov (United States)

    Mori, Makoto; Shioda, Kayoko; Yun, James J; Mangi, Abeel A; Darr, Umer; Geirsson, Arnar

    2018-02-01

    Resumption of dual antiplatelet therapy after coronary artery bypass grafting in patients presenting with acute coronary syndrome is recommended, but the current practice pattern in the United States remains unknown. We aimed to investigate the current pattern of dual antiplatelet therapy use after coronary artery bypass grafting at the Yale-New Haven Hospital. We conducted a single-center retrospective review of patients who presented with acute coronary syndrome and underwent coronary artery bypass grafting between 2014 and 2016. The primary outcome was hospital discharge with dual antiplatelet therapy. Mixed-effect multivariate logistic regression was used to evaluate predictors of dual antiplatelet therapy use or nonuse, accounting for surgeon-specific preference. The discriminatory ability of the model was evaluated with receiver operating characteristics analysis. Of 572 patients included, only 29% were discharged with dual antiplatelet therapy. In the mixed-effect multivariate model isolating surgeon preferences, increase in age (odds ratio, 0.95; 95% confidence interval, 0.92-0.98; P dual antiplatelet therapy use. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting was associated with increased odds of dual antiplatelet therapy use (odds ratio, 31.5; 95% confidence interval, 12.8-77.2; P dual antiplatelet therapy use in patients with acute coronary syndrome who underwent coronary artery bypass grafting was low and variable among surgeons. The use or nonuse was guided by previously established risk factors of recurrent ischemia and bleeding, along with surgeon preference. Published by Elsevier Inc.

  9. Effects of ionizing scrape-off layers on local recycling in Tore Supra pump limiter experiments

    International Nuclear Information System (INIS)

    Owen, L.W.; Hogan, J.T.; Klepper, C.C.; Mioduszewski, P.K.; Uckan, T.; Chatelier, M.; Loarer, T.

    1992-01-01

    A series of ohmic discharges with active pumping in the Tore Supra outboard pump limiter has been analyzed with the DEGAS neutrals transport code and an analysis scrape-off layer (SOL) plasma model. Pumping speed and plenum pressure measurements indicated 5--10 torr-L/s throughput with only modest effects on density (dN core /dt + source rate from ionization and dissociation of wall-desorbed molecules is seen to peak very near the radial position of the limiter throat. Consequently, a strong recycling vortex is created in the region of the limiter, with the ion flux amplified by factors of ∼2 at the outer limiter surfaces and >3 within the limiter throat. The calculations indicate that less than 30% of the pump throughput is due to first-generation ions from the core efflux, with the balance from local recycling in the strongly ionizing scrape-off layer

  10. TRADING-OFF CONSTRAINTS IN THE PUMP SCHEDULING OPTIMIZATION OF WATER DISTRIBUTION NETWORKS

    Directory of Open Access Journals (Sweden)

    Gencer Genço\\u011Flu

    2016-01-01

    Full Text Available Pumps are one of the essential components of water supply systems. Depending of the topography, a water supply system may completely rely on pumping. They may consume non-negligible amount of water authorities' budgets during operation. Besides their energy costs, maintaining the healthiness of pumping systems is another concern for authorities. This study represents a multi-objective optimization method for pump scheduling problem. The optimization objective contains hydraulic and operational constraints. Switching of pumps and usage of electricity tariff are assumed to be key factors for operational reliability and energy consumption and costs of pumping systems. The local optimals for systems operational reliability, energy consumptions and energy costs are investigated resulting from trading-off pump switch and electricity tariff constraints within given set of boundary conditions. In the study, a custom made program is employed that combines genetic algorithm based optimization module with hydraulic network simulation software -EPANET. Developed method is applied on the case study network; N8-3 pressure zone of the Northern Supply of Ankara (Turkey Water Distribution Network. This work offers an efficient method for water authorities aiming to optimize pumping schedules considering expenditures and operational reliability mutually.

  11. CArbon dioxide surgical field flooding and aortic NO-touch off-pump coronary artery bypass grafting to reduce Neurological injuries after surgical coronary revascularisation (CANON): protocol for a randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms.

    Science.gov (United States)

    Krzysztof, Szwed; Wojciech, Pawliszak; Zbigniew, Serafin; Mariusz, Kowalewski; Remigiusz, Tomczyk; Damian, Perlinski; Magdalena, Szwed; Marta, Tomaszewska; Lech, Anisimowicz; Alina, Borkowska

    2017-07-10

    Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. NCT03074604; Pre-results. 10-Mar-2017 Original. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Influencing factors for early acute cerebrovascular accidents in patients with stroke history following off-pump coronary artery bypass grafting.

    Science.gov (United States)

    Wang, Bin; Jia, Ming; Jia, Shijie; Wan, Jiuhe; Zhou, Xiao; Luo, Zhimin; Zhou, Ye; Zhang, Jianqun

    2014-06-01

    To analyse risk factors for early acute cerebrovascular accidents following off-pump coronary artery bypass grafting (OPCAB) in patients with stroke history, and to propose preventive measures to reduce the incidence of these events. A total of 468 patients with a history of stroke underwent OPCAB surgery in Beijing Anzhen Hospital of China from January 2010 to September 2012. They were retrospectively divided into two groups according to the occurrence of early acute cerebrovascular accidents within 48 hours following OPCAB. Multivariate logistic regression analysis was used to find risk or protective factors for early acute cerebrovascular accidents following the OPCAB. Fifty-two patients (11.1%) suffered from early acute cerebrovascular accidents in 468 patients, including 39 cases of cerebral infarction, two cases of cerebral haemorrhage, 11 cases of transient ischaemic attack (TIA). There were significant differences between the two groups in preoperative left ventricular ejection fraction ≤ 35%, severe bilateral carotid artery stenosis, poorly controlled hypertension, intraoperative application of Enclose® II proximal anastomotic device, postoperative acute myocardial infarction, atrial fibrillation, hypotension, ventilation time > 48h, ICU duration >48h and mortality. Multivariate logistic regression analysis showed that preoperative severe bilateral carotid stenosis (OR=6.378, 95%CI: 2.278-20.987) and preoperative left ventricular ejection fraction ≤ 35% (OR=2.737, 95%CI: 1.267-6.389), postoperative acute myocardial infarction (OR=3.644, 95%CI: 1.928-6.876), postoperative atrial fibrillation (OR=3.104, 95%CI:1.135∼8.016) and postoperative hypotension (OR=4.173, 95%CI: 1.836∼9.701) were independent risk factors for early acute cerebrovascular accidents in patients with a history of stroke following OPCAB procedures, while intraoperative application of Enclose® II proximal anastomotic device was protective factor (OR=0.556, 95%CI: 0.337-0.925). This

  13. Thoracic epidural analgesia in obese patients with body mass index of more than 30 kg/m 2 for off pump coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Sharma Munish

    2010-01-01

    Full Text Available Perioperative Thoracic epidural analgesia (TEA is an important part of a multimodal approach to improve analgesia and patient outcome after cardiac and thoracic surgery. This is particularly important for obese patients undergoing off pump coronary artery bypass surgery (OPCAB. We conducted a randomized clinical trial at tertiary care cardiac institute to compare the effect of TEA and conventional opioid based analgesia on perioperative lung functions and pain scores in obese patients undergoing OPCAB. Sixty obese patients with body mass index> 30 kg/m 2 for elective OPCAB were randomized into two groups (n=30 each. Patients in both the groups received general anesthesia but in group 1, TEA was also administered. We performed spirometry as preoperative assessment and at six hours, 24 hours, second, third, fourth and fifth day after extubation, along with arterial blood gases analysis. Visual analogue scale at rest and on coughing was recorded to assess the degree of analgesia. The other parameters observed were: time to endotracheal extubation, oxygen withdrawal time and intensive care unit length of stay. On statistical analysis there was a significant difference in Vital Capacity at six hours, 24 hours, second and third day postextubation. Forced vital capacity and forced expiratory volume in one second followed the same pattern for first four postoperative days and peak expiratory flow rate remained statistically high till second postoperative day. ABG values and PaO 2 /FiO 2 ratio were statistically higher in the study group up to five days. Visual analogue scale at rest and on coughing was significantly lower till fourth and third postoperative day respectively. Tracheal extubation time, oxygen withdrawal time and ICU stay were significantly less in group 1. The use of TEA resulted in better analgesia, early tracheal extubation and shorter ICU stay and should be considered for obese patients undergoing OPCAB.

  14. The impact of avoiding cardiopulmonary by-pass during coronary artery bypass surgery in elderly patients: the Danish On-pump Off-pump Randomisation Study (DOORS)

    DEFF Research Database (Denmark)

    Houlind, Kim; Kjeldsen, Bo Juul; Madsen, Susanne Nørgaard

    2009-01-01

    BACKGROUND: Coronary Artery Bypass Graft operation for ischemic heart disease provides improved quality of life and, in some patients, prolonged survival. Concern has, however, been raised about complications that may be related to the use of cardiopulmonary by-pass (CPB) and aortic cross......-clamping. It has been hypothesized that when coronary artery by-pass grafting is performed without the use of CPB, the rate of serious complications is reduced. METHODS/DESIGN: The trial is designed as an open, randomized, controlled, clinical trial with blinded assessment of end-points. Patients at or above 70...... years of age, referred for surgical myocardial revascularisation, are included and randomised to receive coronary artery by-pass grafting either with or without the use of CPB and aortic cross-clamping. Follow-up is performed by clinical, biochemical, electrocardiographic, and angiographic data...

  15. Analysis of off-grid hybrid wind turbine/solar PV water pumping systems

    Science.gov (United States)

    While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic , wind-electric, diesel powered), very few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) a...

  16. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    Guizilini Solange

    2012-01-01

    Full Text Available Abstract Background Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG. Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary function parameters, clinical outcomes, and pain score between patients undergoing pleurotomy with pleural drain placed in the subxyphoid position and patients with intact pleural cavity after off-pump CABG (OPCAB using left internal thoracic artery (LITA. Methods Seventy-one patients were allocated into two groups: I (n = 38 open left pleural cavity and pleural drain inserted in the subxyphoid position; II (n = 33 intact pleural cavity. Pulmonary function tests and clinical parameters were recorded preoperatively and on postoperative days (POD 1, 3 and 5. Arterial blood gas analysis and shunt fraction were evaluated preoperatively and in POD1. Pain score was assessed on POD1. To monitor pleural effusion and atelectasis chest radiography was performed routinely 1 day before operation and until POD5. Results In both groups a significant impairment was found in lung function parameters until on POD5. However, no significant difference in forced vital capacity and forced expiratory volume in 1 second were seen between groups. A significant decrease in partial pressure of arterial oxygen and an increase in shunt fraction values were observed on POD1 in both groups, but no statistical difference was found when the groups were compared. Pleural effusion and atelectasis until on POD5 were similar in both groups. There were no statistical differences in pain score, duration of mechanical ventilation and postoperative hospital stay between groups. Conclusion Subxyphoid

  17. Comparison of Early Outcomes with Three Approaches for Combined Coronary Revascularization and Carotid Endarterectomy

    Directory of Open Access Journals (Sweden)

    Arzu Antal Dönmez

    Full Text Available Abstract Objective: This study aims to compare three different surgical approaches for combined coronary and carotid artery stenosis as a single stage procedure and to assess effect of operative strategy on mortality and neurological complications. Methods: This retrospective study involves 136 patients who had synchronous coronary artery revascularization and carotid endarterectomy in our institution, between January 2002 and December 2012. Patients were divided into 3 groups according to the surgical technique used. Group I included 70 patients who had carotid endarterectomy, followed by coronary revascularization with on-pump technique, group II included 29 patients who had carotid endarterectomy, followed by coronary revascularization with off-pump technique, group III included 37 patients who had coronary revascularization with on-pump technique followed by carotid endarterectomy under aortic cross-clamp and systemic hypothermia (22-27ºC. Postoperative outcomes were evaluated. Results: Overall early mortality and stroke rate was 5.1% for both. There were 3 (4.3% deaths in group I, 2 (6.9% deaths in group II and 2 (5.4% deaths in group III. Stroke was observed in 5 (7.1% patients in group I and 2 (6.9% in group II. Stroke was not observed in group III. No statistically significant difference was observed for mortality and stroke rates among the groups. Conclusion: We identified no significant difference in mortality or neurologic complications among three approaches for synchronous surgery for coronary and carotid disease. Therefore it is impossible to conclude that a single principle might be adapted into standard practice. Patient specific risk factors and clinical conditions might be important in determining the surgical tecnnique.

  18. [Advances in animal model and traditional Chinese medicine prevention in coronary microvascular dysfunction].

    Science.gov (United States)

    Li, Lei; Liu, Jian-Xun; Ren, Jian-Xun; Guo, Hao; Lin, Cheng-Ren

    2017-01-01

    Coronary microvascular dysfunction (CMD) is a common mechanism for some heart disease like cardiac X syndrome and no-reflow phenomenon after percutaneous coronary intervention(PCI). With the development of medical imageology, CMD has received increased attention. Animal model of CMD is indispensable tool for the research of pathogenesis and treatment evaluation, therefor choose an appropriate animal model is the first issue to carry out CMD research. Experimental and clinical studies have shown unique effectiveness of traditional Chinese medicine(TCM) in CMD therapy. Clarifying of the TCM therapeutic effect mechanisms and seeking an optimal solution of combination of traditional Chinese and western medicine will be the focus of future research. This paper reviewed the establishment and evaluation of CMD animal model, as well as the intervention study of TCM on CMD. The article aims to provide reference for the basic research of CMD and the TCM experimental study on CMD. Copyright© by the Chinese Pharmaceutical Association.

  19. Morphometry of the coronary ostia and the structure of coronary arteries in the shorthair domestic cat.

    Directory of Open Access Journals (Sweden)

    Karolina Barszcz

    Full Text Available The aim of this study was to measure the area of the coronary ostia, assess their localization in the coronary sinuses and to determine the morphology of the stem of the left and right coronary arteries in the domestic shorthair cat. The study was conducted on 100 hearts of domestic shorthair cats of both sexes, aged 2-18 years, with an average body weight of 4.05 kg. A morphometric analysis of the coronary ostia was carried out on 52 hearts. The remaining 48 hearts were injected with a casting material in order to carry out a morphological assessment of the left and right coronary arteries. In all the studied animals, the surface of the left coronary artery ostium was larger than the surface of the right coronary artery ostium. There were four types of the left main coronary artery: type I (23 animals, 49%-double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch, which in turn gave off the septal branch, type II (12 animals, 26%-double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch without the septal branch, type III (11 animals, 23%-triple-branched left main stem (giving off the left circumflex branch, interventricular branch and the septal branch, type IV (1 animal, 2%-double-branched left main stem (giving off the interventricular paraconal branch and the left circumflex branch, which in turn gave off the septal branch. The left coronary artery ostium is greater than the right one. There is considerable diversity in the branches of proximal segment of the left coronary artery, while the right coronary artery is more conservative. These results can be useful in defining the optimal strategies in the endovascular procedures involving the coronary arteries or the aortic valve in the domestic shorthair cat.

  20. Health-related quality of life following off-pump versus on-pump coronary artery bypass grafting in elderly moderate to high-risk patients

    DEFF Research Database (Denmark)

    Jensen, Birte Østergaard; Hughes, Pia; Rasmussen, Lars S

    2006-01-01

    Previous trials comparing coronary artery bypass grafting (CABG) with or without extracorporeal circulation have mainly enrolled selected patients at younger age and low risk. Patient-reported health-related quality of life has not been significantly different. We compared health-related quality...

  1. Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Shahrbano Shahbazi

    2013-12-01

    Full Text Available Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG. Methods: In 146 patients scheduled for on-pump CABG, the liver function test was done preoperatively and on the first postoperative day. Some preoperative and intraoperative risk factors were checked and then the postoperative liver function tests were compared with the preoperative ones. Probable relationships between these changes and the preoperative and intraoperative risk factors were studied. Results: A medical history of diabetes had a significant relationship with the changes in direct bilirubin. Preoperative central venous pressure had a significant relationship with the changes in aspartate aminotransferase and alanine aminotransferase. Use of intra-aortic balloon pump and duration of aortic cross-clamp were significantly related to the changes in the liver function tests except for alanine aminotransferase and alkaline phosphatase. Conclusion: It seems that the techniques for the reduction of cardiopulmonary bypass and aortic cross-clamp duration may be useful to protect liver function. We recommend that a larger population of patients be studied to confirm these findings.

  2. Morphometry of the coronary ostia and the structure of coronary arteries in the shorthair domestic cat

    Science.gov (United States)

    Barszcz, Karolina; Kupczyńska, Marta; Klećkowska-Nawrot, Joanna; Janeczek, Maciej; Goździewska-Harłajczuk, Karolina; Dzierzęcka, Małgorzata; Janczyk, Paweł

    2017-01-01

    The aim of this study was to measure the area of the coronary ostia, assess their localization in the coronary sinuses and to determine the morphology of the stem of the left and right coronary arteries in the domestic shorthair cat. The study was conducted on 100 hearts of domestic shorthair cats of both sexes, aged 2–18 years, with an average body weight of 4.05 kg. A morphometric analysis of the coronary ostia was carried out on 52 hearts. The remaining 48 hearts were injected with a casting material in order to carry out a morphological assessment of the left and right coronary arteries. In all the studied animals, the surface of the left coronary artery ostium was larger than the surface of the right coronary artery ostium. There were four types of the left main coronary artery: type I (23 animals, 49%)–double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch, which in turn gave off the septal branch), type II (12 animals, 26%)–double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch without the septal branch), type III (11 animals, 23%)–triple-branched left main stem (giving off the left circumflex branch, interventricular branch and the septal branch, type IV (1 animal, 2%)–double-branched left main stem (giving off the interventricular paraconal branch and the left circumflex branch, which in turn gave off the septal branch). The left coronary artery ostium is greater than the right one. There is considerable diversity in the branches of proximal segment of the left coronary artery, while the right coronary artery is more conservative. These results can be useful in defining the optimal strategies in the endovascular procedures involving the coronary arteries or the aortic valve in the domestic shorthair cat. PMID:29020103

  3. Investigation of Pumped Storage Hydropower Power-Off Transient Process Using 3D Numerical Simulation Based on SP-VOF Hybrid Model

    Directory of Open Access Journals (Sweden)

    Daqing Zhou

    2018-04-01

    Full Text Available The transient characteristic of the power-off process is investigated due to its close relation to hydraulic facilities’ safety in a pumped storage hydropower (PSH. In this paper, power-off transient characteristics of a PSH station in pump mode was studied using a three-dimensional (3D unsteady numerical method based on a single-phase and volume of fluid (SP-VOF coupled model. The computational domain covered the entire flow system, including reservoirs, diversion tunnel, surge tank, pump-turbine unit, and tailrace tunnel. The fast changing flow fields and dynamic characteristic parameters, such as unit flow rate, runner rotate speed, pumping lift, and static pressure at measuring points were simulated, and agreed well with experimental results. During the power-off transient process, the PSH station underwent pump mode, braking mode, and turbine mode, with the dynamic characteristics and inner flow configurations changing significantly. Intense pressure fluctuation occurred in the region between the runner and guide vanes, and its frequency and amplitude were closely related to the runner’s rotation speed and pressure gradient, respectively. While the reversed flow rate of the PSH unit reached maximum, some parameters, such as static pressure, torque, and pumping lift would suddenly jump significantly, due to the water hammer effect. The moment these marked jumps occurred was commonly considered as the most dangerous moment during the power-off transient process, due to the blade passages being clogged by vortexes, and chaos pressure distribution on the blade surfaces. The results of this study confirm that 3D SP-VOF hybrid simulation is an effective method to reveal the hydraulic mechanism of the PSH transient process.

  4. Prevalence and intensity of hyperglycemia in non-diabetic patients undergoing coronary artery bypass graft surgery with and without cardiopulmonary bypass

    International Nuclear Information System (INIS)

    Azarfarin, R.; Asl, Azin A.

    2008-01-01

    Objective was to study the prevalence and severity of hyperglycemia in nondiabetic patients undergoing cardiac operation. In an observational prospective study, 282 non-diabetic patients underwent elective off-pump (n=101) or non on-pump (n=181) coronary artery bypass grafting (CABG) surgery from March 2006 to July 2007 in Madani Heart Hospital, Tabriz, Iran. Blood glucose (BG) levels were measured during and 24 hours after operation. Frequencies of hyperglycemia (BG>-126 mg/dl) and severe hyperglycemia (BG>-180 mg/dl) and postoperative complications were compared in the 2 study groups. Prevalence of at least one episode of severe hyperglycemia was 54.6% (154/282) in our patients during and 24 hours after operation. Intra-operative hyperglycemia was slightly higher in on-pumping group. Frequency of post-operative hyperglycemia was higher, although not significantly different between the two groups. The 2 study groups were not significantly different in frequency of severe hyperglycemia during operation, although were different within 24 hours postoperative period. Prevalence of hyperglycemia especially severe hyperglycemia was high during, and after operation in both off-pump and on-pump CABG in non-diabetic patients. There was a borderline difference in blood glucose level between on-pump and off-pump CABG patients. It may be prudent to consider glycemic control protocols in these patients especially in early post-operative period. (author)

  5. Miniesternotomia na cirurgia de revascularização miocárdica sem circulação extracorpórea Ministernotomy in off-pump coronary artery bypass surgery

    Directory of Open Access Journals (Sweden)

    Walter J. Gomes

    2005-12-01

    Full Text Available OBJETIVO: Os pacientes com lesão isolada da artéria coronária descendente anterior (ADA se beneficiam mais do tratamento cirúrgico do que com intervenção percutânea. Entretanto, com a menor invasividade da intervenção percutânea, a maioria dos pacientes tem sido direcionada para este procedimento. Relatamos a utilização da miniesternotomia inferior como abordagem para o tratamento de pacientes com lesão única de ADA, com anastomose do enxerto de artéria torácica interna esquerda (ATIE, sem uso de circulação extracorpórea (CEC. MÉTODO: Foram estudados 14 pacientes operados consecutivamente utilizando esta técnica, na qual o enxerto de ATIE foi anastomosado à ADA. A idade média dos pacientes foi 56,7±10,1 anos. A incisão cutânea tinha entre 7 e 9 cm e a porção inferior do esterno foi aberta longitudinalmente. A anastomose foi facilitada com o uso de estabilizadores Octopus-3® (Medtronic. RESULTADOS: Todos os pacientes tiveram boa evolução pós-operatória, com alta hospitalar entre 2 e 6 dias de PO (mediana 3 dias. Não houve alteração de ECG ou elevação enzimática neste grupo. Um paciente foi reinternado por infecção de ferida operatória. CONCLUSÃO: A miniesternotomia permite a realização segura do procedimento cirúrgico de revascularização miocárdica da ADA, sem CEC, com benefício em longo-termo do uso da ATIE.OBJECTIVE: Patients with isolated lesions in the proximal left anterior descending artery (LAD have been demonstrated to benefit more from surgical treatment than percutaneous coronary intervention (PCI. However, with the less invasiveness of PCI, the majority of the patients have been referred for this latter procedure. We report herein on the inferior ministernotomy approach for the treatment of patients with single LAD lesions, with off-pump anastomosis of the left internal thoracic artery graft. METHOD: Fourteen patients, consecutively operated on using this technique with the LITA graft

  6. Nonselective carotid artery ultrasound screening in patients undergoing coronary artery bypass grafting: Is it necessary?

    Science.gov (United States)

    Masabni, Khalil; Sabik, Joseph F.; Raza, Sajjad; Carnes, Theresa; Koduri, Hemantha; Idrees, Jay J.; Beach, Jocelyn; Riaz, Haris; Shishehbor, Mehdi H.; Gornik, Heather L.; Blackstone, Eugene H.

    2016-01-01

    Objectives To determine whether nonselective preoperative carotid artery ultrasound screening alters management of patients scheduled for coronary artery bypass grafting (CABG), and whether such screening affects neurologic outcomes. Methods From March 2011 to September 2013, preoperative carotid artery ultrasound screening was performed on 1236 of 1382 patients (89%) scheduled to undergo CABG. Carotid artery stenosis (CAS) was classified as none or mild (any type 0%–59% stenosis), moderate (unilateral 60%-79% stenosis), or severe (bilateral 60%-79% stenosis or unilateral 80%–100% stenosis). Results A total of 1069 (86%) hadoff-pump surgery. Of those with severe CAS, 18 (23%) had confirmatory testing, and 18 (23%) underwent combined CABG + CEA; 6 (7.8%) had off-pump surgery. Stroke occurred in 14 of 1069 (1.3%) patients with off-pump and 1 of 79 (1.3%) on-pump patients (P = .2). In patients with severe CAS, stroke occurred in 1 of 6 (17%) off-pump and 1 of 71 (1.4%) on-pump patients (P = .15). Conclusions Routine preoperative carotid artery evaluation altered the management of a minority of patients undergoing CABG; this did not translate into perioperative stroke risk. Hence, a more targeted approach for preoperative carotid artery evaluation should be adopted. PMID:26586360

  7. Transient simulation of coolant peak temperature due to prolonged fan and/or water pump operation after the vehicle is keyed-off

    Science.gov (United States)

    Pang, Suh Chyn; Masjuki, Haji Hassan; Kalam, Md. Abul; Hazrat, Md. Ali

    2014-01-01

    Automotive designers should design a robust engine cooling system which works well in both normal and severe driving conditions. When vehicles are keyed-off suddenly after some distance of hill-climbing driving, the coolant temperature tends to increase drastically. This is because heat soak in the engine could not be transferred away in a timely manner, as both the water pump and cooling fan stop working after the vehicle is keyed-off. In this research, we aimed to visualize the coolant temperature trend over time before and after the vehicles were keyed-off. In order to prevent coolant temperature from exceeding its boiling point and jeopardizing engine life, a numerical model was further tested with prolonged fan and/or water pump operation after keying-off. One dimensional thermal-fluid simulation was exploited to model the vehicle's cooling system. The behaviour of engine heat, air flow, and coolant flow over time were varied to observe the corresponding transient coolant temperatures. The robustness of this model was proven by validation with industry field test data. The numerical results provided sensible insights into the proposed solution. In short, prolonging fan operation for 500 s and prolonging both fan and water pump operation for 300 s could reduce coolant peak temperature efficiently. The physical implementation plan and benefits yielded from implementation of the electrical fan and electrical water pump are discussed.

  8. Early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome versus stable angina pectoris.

    Science.gov (United States)

    Fukui, Toshihiro; Tabata, Minoru; Morita, Satoshi; Takanashi, Shuichiro

    2013-06-01

    The aim of the present study was to determine the early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome and stable angina pectoris. From September 2004 to September 2011, 382 patients with acute coronary syndrome (unstable angina pectoris and non-ST-segment elevation myocardial infarction) and 851 patients with stable angina pectoris underwent first-time isolated coronary artery bypass grafting at our institute. The early and long-term outcomes were compared between the 2 groups. Patients with acute coronary syndrome were older, were more likely to be women, had a smaller body surface area, and were more likely to have left main coronary artery disease. In both groups, bilateral internal thoracic artery grafts were used in approximately 89% of the patients, and off-pump techniques in approximately 97% of the patients. The acute coronary syndrome group had a greater operative death rate (2.6% vs 0.1%) and a greater incidence of low output syndrome (3.1% vs 1.2%) and hemodialysis requirement (2.9% vs 1.1%). Multivariate regression analysis demonstrated that age, acute coronary syndrome, lower ejection fraction, and higher creatinine level before surgery were independent predictors of operative death. However, among the hospital survivors, no differences were seen in freedom from all death (85.4% ± 2.5% vs 87.7% ± 2.0%), cardiac death (97.4% ± 0.9% vs 96.5% ± 0.9%), or major adverse cardiac and cerebrovascular events (78.0% ± 2.9% vs 78.1% ± 2.3%) at 7 years between the patients with acute coronary syndrome and stable angina pectoris. Although acute coronary syndrome is an independent predictor of early mortality in patients undergoing coronary artery bypass grafting, the long-term outcomes after surgery were similar between patients with acute coronary syndrome and stable angina pectoris who survived the early postoperative period. Copyright © 2013 The American Association for Thoracic Surgery. Published by

  9. Role of Acid and Weakly Acidic Reflux in Gastroesophageal Reflux Disease Off Proton Pump Inhibitor Therapy

    OpenAIRE

    Sung, Hea Jung; Cho, Yu Kyung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye

    2012-01-01

    Background/Aims Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. Methods We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. T...

  10. Numerical investigation of solid-liquid two phase flow in a non-clogging centrifugal pump at off-design conditions

    International Nuclear Information System (INIS)

    Zhao, B J; Chen, H L; Hou, D H; Huang, Z F

    2012-01-01

    The solid-liquid two-phase flow fields in the non-clogging centrifugal pump with a double-channel impeller have been investigated numerically for the design condition and also off-design conditions, in order to study the solid-liquid two-phase flow pattern and non-clogging mechanism in non-clogging centrifugal pumps. The main conclusions include: The sand volume fraction distribution is extremely inhomogeneous in the whole flow channel of the pump at off-design conditions. In the impeller, particles mainly flow along the pressure surface and hub; In the volute, particles mainly accumulate in the region near to the exit of volute, the largest sand volume fraction is observed at the tongue, and a large number of particles collide with volute wall and exit the volute after circling around the volute for several times. When the particle diameter increases, particles tend to accumulate on the pressure side of the impeller, and more particles crash with the pressure side of the blade. And larger sand volume fraction gratitude is also observed in the whole flow channel of the pump. With the decrease of the inlet sand volume fraction, particles tend to accumulate on the suction side of the blade. Compared with the particle diameter, the inlet sand volume fraction has less influence on the sand volume fraction gratitude in the whole channel of the pump. At the large flow rate, the minimum and maximum sand volume fraction in the whole flow channel of the model pump tends to be smaller than that at the small flow rate. Thus, it is concluded that the water transportation capacity increases with the flow rate. This research will strengthen people's understanding of the multiphase flow pattern in non-clogging centrifugal pumps, thus provides a theoretical basis for the optimal design of non-clogging centrifugal pumps.

  11. Effects of ionizing scrape-off layers on local recycling in Tore Supra pump limiter experiments

    International Nuclear Information System (INIS)

    Chatelier, M.; Loarer, T.

    1992-01-01

    A series of ohmic discharges with active pumping in the Tore Supra outboard pump limiter has been analyzed with the DEGAS neutrals transport code and an analytic scrape-off layer (SOL) plasma model. Pumping speed and plenum pressure measurements indicated 5-10 torr.L/s throughput with only modest effects on density. A model is developed in which large exhaust fluxes, with little attendant effect on core plasma density, are explained in terms of SOL ionization of recycled and wall-desorbed neutrals. Particle balance with active pumping and constant line density requires that the wall return flux exceed the incident flux by approximately the pump throughput in the absence of external fueling. The radial profile of the H + source rate from ionization and dissociation of wall-desorbed molecules is seen to peak very near the radial position of the limiter throat. Consequently, a strong recycling vortex is created in the region of the limiter, with the ion flux amplified by factors of 2 at the outer limiter surfaces and > 3 within the limiter throat. The calculations indicate that less than 30% of the pump throughput is due to first-generation ions from the core efflux, with the balance from local recycling in the strongly ionizing SOL

  12. Pneumoproteins as a lung-specific biomarker of alveolar permeability in conventional on-pump coronary artery bypass graft surgery vs mini-extracorporeal circuit - A pilot study

    NARCIS (Netherlands)

    van Boven, WJP; Gerritsen, WBM; Zanen, P; Grutters, JC; van Dongen, HPA; Bernard, A; Aarts, LPHJ

    Background: Despite improvements of the heart-lung machine (HLM), oxidative stress and subsequent damage to the alveolar capillary membrane still occur after conventional on-pump coronary artery bypass graft (CCABG) surgery. In an attempt to further improve the conventional HLM, a

  13. Temporary diabetes insipidus in 2 men after on-pump coronary artery bypass grafting.

    Science.gov (United States)

    Uyar, Ihsan Sami; Sahin, Veysel; Akpinar, Besir; Yurtman, Volkan; Abacilar, Feyzi; Okur, Faik Fevzi; Ates, Mehmet

    2013-01-01

    Many complications have been reported after cardiopulmonary bypass. A common physiologic change during the early postoperative period after cardiopulmonary bypass is increased diuresis. In patients whose urine output is increased, postoperative diabetes insipidus can develop, although reports of this are rare. We present the cases of 2 patients who underwent on-pump coronary artery bypass grafting (with cardiopulmonary bypass). Each was diagnosed with diabetes insipidus postoperatively: a 54-year-old man on the 3rd day, and a 66-year-old man on the 4th day. Each patient recovered from the condition after 6 hours of intranasal therapy with synthetic vasopressin (antidiuretic hormone). The diagnosis of diabetes insipidus should be considered in patients who produce excessive urine early after cardiac surgery in which cardiopulmonary bypass has been used.

  14. Improved Approach With Subcostal Exchange of the HeartMate II Left Ventricular Assist Device: Difference in On and Off Pump?

    Science.gov (United States)

    Gaffey, Ann C; Chen, Carol W; Chung, Jennifer J; Phillips, Emily; Wald, Joyce; Williams, Matthew L; Low, David W; Acker, Michael A; Atluri, Pavan

    2017-11-01

    The HeartMate II (St. Jude Medical, Inc, St. Paul, MN [previously Thoratec]) left ventricular assist device (LVAD) exchange has traditionally involved a redo sternotomy. Alternate minimally invasive subcostal approaches have the advantage of avoiding sternal reentry, excessive bleeding, and prolonged recovery. This retrospective review included patients who underwent an exchange from May 2009 to March 2016. The patients were divided into three cohorts: (1) redo sternotomy, (2) subcostal approach involving cardiopulmonary bypass (CPB) (ON-CPB SC), and (3) subcostal approach off the CPB pump (OFF-CPB SC). Data pertaining to patients' baseline characteristics and outcomes were collected and analyzed. From May 1, 2009 to July 31, 2016, 33 HeartMate II LVAD exchanges were performed. There were 11 redo sternotomies and 22 subcostal exchanges, 12 of which were in the OFF-CPB SC group. There was no significant difference among the groups in terms of age (p = 0.75), sex (p = 0.95), and indication for exchange (p = 0.94). There was a higher red blood cell transfusion requirement within the sternotomy cohort (p rates were equivalent among the cohorts. Exchange of the HeartMate II LVAD can be accomplished with significantly improved recovery time and transfusion requirement through a less invasive subcostal approach when compared with sternotomy. The subcostal approach can be performed safely both on and off cardiopulmonary bypass. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  16. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, A. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States); Easley, S. [Building Media and the Building America Retrofit Alliance (BARA), Wilmington, DE (United States)

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  17. Indication and short-term clinical outcomes of high-risk percutaneous coronary intervention with microaxial Impella® pump: results from the German Impella® registry.

    Science.gov (United States)

    Baumann, Stefan; Werner, Nikos; Ibrahim, Karim; Westenfeld, Ralf; Al-Rashid, Fadi; Sinning, Jan-Malte; Westermann, Dirk; Schäfer, Andreas; Karatolios, Konstantinos; Bauer, Timm; Becher, Tobias; Akin, Ibrahim

    2018-03-08

    Percutaneous coronary intervention (PCI) is an alternative strategy to coronary artery bypass grafting (CABG) in patients with high perioperative risk. The microaxial Impella ® pump (Abiomed, Danvers, MA, USA), used as prophylactic and temporary support, is currently the most common device for "protected high-risk PCI" to ensure hemodynamic stability during complex coronary intervention. The study is an observational, retrospective multi-center registry. Patients from nine tertiary hospitals in Germany, who have undergone protected high-risk PCI, are included in the present study. A total of 154 patients (mean age 72.6-10.8 years, 75.3% male) were enrolled. The majority were at a high operative risk illustrated by a logistic EuroSCORE of 14.7-17.4. The initial SYNTAX score was 32.0-13.3, indicating very complex CAD and could be reduced to 14.1-14.3 (p study show that protected PCI is a safe and effective approach to revascularize high-risk patients with complex coronary anatomy and comorbidities.

  18. Mechanical design and modeling of a single-piston pump for the novel power take-off system of a wave energy converter

    NARCIS (Netherlands)

    Vakis, Antonis I.; Anagnostopoulos, John S.

    2016-01-01

    A multi-pump, multi-piston power take-off wave energy converter ((MPPTO)-P-2 WEC) has been proposed for use with a novel renewable energy harvester termed the Ocean Grazer. The (MPPTO)-P-2 WEC utilizes wave motion to pump via buoys connected to pistons working fluid within a closed circuit and store

  19. Development and evaluation of cryosorption pump and cryotrapping pump for CTR applications

    International Nuclear Information System (INIS)

    Kuribayashi, S.; Ota, H.; Sato, H.

    1986-01-01

    In order to obtain the engineering data to design compound cryopump for CTR, the authors tested the cryosorption pump and cryotrapping pump. The cryosorption panel was consisted of coconut charcoal metallically bonded to 4.2K cryopanel by brazing. The initial pumping speed of helium of cryosorption pump was found to be ≅2.2 iota/scm/sup 2/. The speed dropped off with loading (about 8 Torr iota/cm/sup 2/) to 1.5 iota/scm/sup 2/. The initial helium pumping speed of the 4.2K cryotrapping pump by argon spray was found to be ≅6 iota/scm/sup 2/. The speed, however, dropped off with loading (≅0.3 Torr iota/cm/sup 2/) to less than 5%. These results indicate that the cryosorption pump by coconut charcoal is superior to the cryotrapping pump, because the capacity of the former is larger than the latter

  20. Heart bypass surgery

    Science.gov (United States)

    Off-pump coronary artery bypass; OPCAB; Beating heart surgery; Bypass surgery - heart; CABG; Coronary artery bypass graft; Coronary artery bypass surgery; Coronary bypass surgery; Coronary artery disease - CABG; CAD - CABG; Angina - ...

  1. Effect of on/off pumping strategy on sewer sediment behvaviour elucidated by high frequecny monitoring at the treatment plan inlte

    DEFF Research Database (Denmark)

    Sharma, Anitha Kumari; Alferes, J.; Vezzaro, Luca

    study illustrates how data with high temporal resolution and advanced DQC tools can be used to: (i) detect unexpected shock loads during dry weather due to an on/off pumping strategy, (ii) understand the processes in upstream sewer systems under wet weather, and (iii) take the necessary actions...... to reduce the shock loads at the WWTP. The results for a selected week show that the on/off pumping strategy creates unnecessary peaks with 50-200% increased flows. This affects the water quality arriving at the WWTP, particularly with respect to the total suspended solids concentrations, which increased...... understand the processes taking place upstream the plant and to reduce their impact on the performance of the WWTP....

  2. Traditional cardiovascular risk factors and coronary artery calcification in adults with polymyositis and dermatomyositis

    DEFF Research Database (Denmark)

    Diederichsen, Louise C. Pyndt Raun; Diederichsen, Axel C P; Simonsen, Jane A

    2015-01-01

    : Traditional CV risk factors were assessed in a cross-sectional, observational study of 76 patients with PM/DM and in 48 sex- and age-matched healthy controls. CAC was quantified by means of cardiac computed tomography scan and expressed in Agatston units. The associations between CV risk factors, PM......OBJECTIVE: To determine the occurrence of traditional cardiovascular (CV) risk factors and coronary artery calcification (CAC) in adults with polymyositis (PM) or dermatomyositis (DM) compared to healthy controls and to assess the association between CV risk factors, PM/DM, and CAC score. METHODS...... of triglycerides (P = 0.0009). High CAC score occurred more frequently in patients (20% versus 4%; P = 0.04). In multivariate analysis of patient factors associated with CAC were age (P = 0.02) and smoking (P = 0.02). CONCLUSION: In this study, traditional CV risk factors and severe CAC were commonly found...

  3. Assessment of feasibility and efficacy of Class IV laser therapy for postoperative pain relief in off-pump coronary artery bypass surgery patients: A pilot study

    Directory of Open Access Journals (Sweden)

    Anil Karlekar

    2015-01-01

    Full Text Available Background: Laser therapy, for its established analgesic properties with minimal side effects, has been used for the treatment of chronic pain. However, it has not been used for the treatment of acute postoperative pain. This pilot study was designed to assess the feasibility and efficacy of Class IV laser on postoperative pain relief following off-pump coronary artery bypass graft (OPCABG surgery, as a component of multimodal analgesia (MMA technique. Methods: This open observational prospective study comprised of 100 adult patients (84 male, 16 female who underwent OPCABG through sternotomy. For postoperative analgesia, they were subjected to laser therapy subjected to laser therapy in addition to the standard institutional pain management protocol comprising of IV infusion/bolus of tramadol and paracetamol and fentanyl bolus as rescue analgesic. Pain intensity was measured by Verbal Rating Scale (VRS. The laser therapy was scheduled as once a day regime for three consecutive postoperative days (PODs starting on POD 1, 30 min following tracheal extubation. The subsequent laser applications were also scheduled at the same time of the day as on day 1 if VRS was ≥5. 10 W Class IV laser was applied over 150 cm 2 sternal wound area for 150 s. VRS was used to assess pain severity and was recorded for statistical analysis using Friedman Test. Results: The mean (standard deviation [SD] VRS of all the 100 patients just before application of the first dose of laser was 7.31 (0.94 while on MMT; the same fell to 4.0 (1.279 and 3.40 (2.697 at 1 h and 24 h respectively following first dose of laser. The change of VRS over first 24 h among all the 100 patients was statistically significant (P = 0.000. Laser was re-applied in 40 patients whose VRS was ≥5 (mean [SD] - 6.38 [0.868] at 24 th h. After receiving the 2 nd dose of laser the VRS scores fell significantly (P = 0.000 and became 0 at 54 th h. No patients required 3 rd dose of the laser. No patient

  4. Flow pumping system for physiological waveforms.

    Science.gov (United States)

    Tsai, William; Savaş, Omer

    2010-02-01

    A pulsatile flow pumping system is developed to replicate flow waveforms with reasonable accuracy for experiments simulating physiological blood flows at numerous points in the body. The system divides the task of flow waveform generation between two pumps: a gear pump generates the mean component and a piston pump generates the oscillatory component. The system is driven by two programmable servo controllers. The frequency response of the system is used to characterize its operation. The system has been successfully tested in vascular flow experiments where sinusoidal, carotid, and coronary flow waveforms are replicated.

  5. Anomalous origin of right coronary artery from left coronary sinus.

    Science.gov (United States)

    Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I

    2008-08-01

    Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.

  6. High efficiency, variable geometry, centrifugal cryogenic pump

    International Nuclear Information System (INIS)

    Forsha, M.D.; Nichols, K.E.; Beale, C.A.

    1994-01-01

    A centrifugal cryogenic pump has been developed which has a basic design that is rugged and reliable with variable speed and variable geometry features that achieve high pump efficiency over a wide range of head-flow conditions. The pump uses a sealless design and rolling element bearings to achieve high reliability and the ruggedness to withstand liquid-vapor slugging. The pump can meet a wide range of variable head, off-design flow requirements and maintain design point efficiency by adjusting the pump speed. The pump also has features that allow the impeller and diffuser blade heights to be adjusted. The adjustable height blades were intended to enhance the pump efficiency when it is operating at constant head, off-design flow rates. For small pumps, the adjustable height blades are not recommended. For larger pumps, they could provide off-design efficiency improvements. This pump was developed for supercritical helium service, but the design is well suited to any cryogenic application where high efficiency is required over a wide range of head-flow conditions

  7. Contribution of genetic background, traditional risk factors, and HIV-related factors to coronary artery disease events in HIV-positive persons

    NARCIS (Netherlands)

    Rotger, Margalida; Glass, Tracy R; Junier, Thomas; Lundgren, Jens; Neaton, James D; Poloni, Estella S; van 't Wout, Angélique B; Lubomirov, Rubin; Colombo, Sara; Martinez, Raquel; Rauch, Andri; Günthard, Huldrych F; Neuhaus, Jacqueline; Wentworth, Deborah; van Manen, Danielle; Gras, Luuk A; Schuitemaker, Hanneke; Albini, Laura; Torti, Carlo; Jacobson, Lisa P; Li, Xiuhong; Kingsley, Lawrence A; Carli, Federica; Guaraldi, Giovanni; Ford, Emily S; Sereti, Irini; Hadigan, Colleen; Martinez, Esteban; Arnedo, Mireia; Egaña-Gorroño, Lander; Gatell, Jose M; Law, Matthew; Bendall, Courtney; Petoumenos, Kathy; Rockstroh, Jürgen; Wasmuth, Jan-Christian; Kabamba, Kabeya; Delforge, Marc; De Wit, Stephane; Berger, Florian; Mauss, Stefan; de Paz Sierra, Mariana; Losso, Marcelo; Belloso, Waldo H; Leyes, Maria; Campins, Antoni; Mondi, Annalisa; De Luca, Andrea; Bernardino, Ignacio; Barriuso-Iglesias, Mónica; Torrecilla-Rodriguez, Ana; Gonzalez-Garcia, Juan; Arribas, José R; Fanti, Iuri; Gel, Silvia; Puig, Jordi; Negredo, Eugenia; Gutierrez, Mar; Domingo, Pere; Fischer, Julia; Fätkenheuer, Gerd; Alonso-Villaverde, Carlos; Macken, Alan; Woo, James; McGinty, Tara; Mallon, Patrick; Mangili, Alexandra; Skinner, Sally; Wanke, Christine A; Reiss, Peter; Weber, Rainer; Bucher, Heiner C; Fellay, Jacques; Telenti, Amalio; Tarr, Philip E; Schölvinck, Elisabeth H.

    BACKGROUND: Persons infected with human immunodeficiency virus (HIV) have increased rates of coronary artery disease (CAD). The relative contribution of genetic background, HIV-related factors, antiretroviral medications, and traditional risk factors to CAD has not been fully evaluated in the

  8. Numerical simulation of hydrodynamics in a pump-turbine at off-design operating conditions in turbine mode

    International Nuclear Information System (INIS)

    Yan, J P; Seidel, U; Koutnik, J

    2012-01-01

    The hydrodynamics of a reduced-scaled model of a radial pump-turbine is investigated under off-design operating conditions, involving runaway and 'S-shape' turbine brake curve at low positive discharge. It is a low specific speed pump-turbine machine of Francis type with 9 impeller blades and 20 stay vanes as well as 20 guide vanes. The computational domain includes the entire water passage from the spiral casing inlet to the draft tube outlet. Completely structured hexahedral meshes generated by the commercial software ANSYS-ICEM are employed. The unsteady incompressible simulations are performed using the commercial code ANSYS-CFX13. For turbulence modeling the standard k-ε model is applied. The numerical results at different operating points are compared to the experimental results. The predicted pressure amplitude is in good agreement with the experimental data and the amplitude of normal force on impeller is in reasonable range. The detailed analysis reveals the onset of the flow instabilities when the machine is brought from a regular operating condition to runaway and turbine break mode. Furthermore, the rotating stall phenomena are well captured at runaway condition as well as low discharge operating condition with one stall cell rotating inside and around the impeller with about 70% of its frequency. Moreover, the rotating stall is found to be the effect of rotating flow separations developed in several consecutive impeller channels which lead to their blockage. The reliable simulation of S-curve characteristics in pump-turbines is a basic requirement for design and optimization at off-design operating conditions.

  9. Supported high-risk percutaneous coronary intervention with the Impella 2.5 device the Europella registry

    DEFF Research Database (Denmark)

    Sjauw, Krischan D; Konorza, Thomas; Erbel, Raimund

    2009-01-01

    OBJECTIVES: This retrospective multicenter registry evaluated the safety and feasibility of left ventricular (LV) support with the Impella 2.5 (Abiomed Europe GmbH, Aachen, Germany) during high-risk percutaneous coronary intervention (PCI). BACKGROUND: Patients with complex or high-risk coronary...... with poor LV function. The Impella 2.5, a percutaneous implantable LV assist device, might be a superior alternative to the traditionally used intra-aortic balloon pump. METHODS: The Europella registry included 144 consecutive patients who underwent a high-risk PCI. Safety and feasibility end points.......5%. Rates of myocardial infarction, stroke, bleeding requiring transfusion/surgery, and vascular complications at 30 days were 0%, 0.7%, 6.2%, and 4.0%, respectively. CONCLUSIONS: This large multicenter registry supports the safety, feasibility, and potential usefulness of hemodynamic support with Impella 2...

  10. Contribution of genetic background, traditional risk factors, and HIV-related factors to coronary artery disease events in HIV-positive persons

    NARCIS (Netherlands)

    Rotger, Margalida; Glass, Tracy R.; Junier, Thomas; Lundgren, Jens; Neaton, James D.; Poloni, Estella S.; van 't Wout, Angélique B.; Lubomirov, Rubin; Colombo, Sara; Martinez, Raquel; Rauch, Andri; Günthard, Huldrych F.; Neuhaus, Jacqueline; Wentworth, Deborah; van Manen, Danielle; Gras, Luuk A.; Schuitemaker, Hanneke; Albini, Laura; Torti, Carlo; Jacobson, Lisa P.; Li, Xiuhong; Kingsley, Lawrence A.; Carli, Federica; Guaraldi, Giovanni; Ford, Emily S.; Sereti, Irini; Hadigan, Colleen; Martinez, Esteban; Arnedo, Mireia; Egaña-Gorroño, Lander; Gatell, Jose M.; Law, Matthew; Bendall, Courtney; Petoumenos, Kathy; Rockstroh, Jürgen; Wasmuth, Jan-Christian; Kabamba, Kabeya; Delforge, Marc; de Wit, Stephane; Berger, Florian; Mauss, Stefan; de Paz Sierra, Mariana; Losso, Marcelo; Belloso, Waldo H.; Leyes, Maria; Campins, Antoni; Mondi, Annalisa; de Luca, Andrea; Bernardino, Ignacio; Barriuso-Iglesias, Mónica; Torrecilla-Rodriguez, Ana; Gonzalez-Garcia, Juan; Arribas, José R.; Fanti, Iuri; Gel, Silvia; Puig, Jordi; Negredo, Eugenia; Gutierrez, Mar; Domingo, Pere; Fischer, Julia; Fätkenheuer, Gerd; Alonso-Villaverde, Carlos; Macken, Alan; Woo, James; McGinty, Tara; Mallon, Patrick; Mangili, Alexandra; Skinner, Sally; Wanke, Christine A.; Reiss, Peter; Weber, Rainer; Bucher, Heiner C.; Fellay, Jacques; Telenti, Amalio; Tarr, Philip E.; Gras, A. Luuk; van Wout, Angelique B.; Arnedo-Valero, Mireia; Sierra, Mariana de Paz; Rodriguez, Ana Torrecilla; Garcia, Juan Gonzalez; Arribas, Jose R.; Aubert, V.; Barth, J.; Battegay, M.; Bernasconi, E.; Böni, J.; Bucher, H. C.; Burton-Jeangros, C.; Calmy, A.; Cavassini, M.; Egger, M.; Elzi, L.; Fehr, J.; Fellay, J.; Francioli, P.; Furrer, H.; Fux, C. A.; Gorgievski, M.; Günthard, H.; Haerry, D.; Hasse, B.; Hirsch, H. H.; Hirschel, B.; Hösli, I.; Kahlert, C.; Kaiser, L.; Keiser, O.; Kind, C.; Klimkait, T.; Kovari, H.; Ledergerber, B.; Martinetti, G.; Martinez de Tejada, B.; Metzner, K.; Müller, N.; Nadal, D.; Pantaleo, G.; Rauch, A.; Regenass, S.; Rickenbach, M.; Rudin, C.; Schmid, P.; Schultze, D.; Schöni-Affolter, F.; Schüpbach, J.; Speck, R.; Taffé, P.; Tarr, P.; Telenti, A.; Trkola, A.; Vernazza, P.; Weber, R.; Prins, Yerly S. J. M.; Kuijpers, T. W.; Scherpbier, H. J.; Boer, K.; van der Meer, J. T. M.; Wit, F. W. M. N.; Godfried, M. H.; van der Poll, T.; Nellen, F. J. B.; Lange, J. M. A.; Geerlings, S. E.; van Vugt, M.; Vrouenraets, S. M. E.; Pajkrt, D.; Bos, J. C.; van der Valk, M.; Schreij, G.; Lowe, S.; Oude Lashof, A.; Pronk, M. J. H.; Bravenboer, B.; van der Ende, M. E.; de Vries-Sluijs, T. E. M. S.; Schurink, C. A. M.; van der Feltz, M.; Nouwen, J. L.; Gelinck, L. B. S.; Verbon, A.; Rijnders, B. J. A.; van de Ven-de Ruiter, E. D.; Slobbe, L.; Haag, Den; Kauffmann, R. H.; Schippers, E. F.; Groeneveld, P. H. P.; Alleman, M. A.; Bouwhuis, J. W.; ten Kate, R. W.; Soetekouw, R.; Kroon, F. P.; van den Broek, P. J.; van Dissel, J. T.; Arend, S. M.; van Nieuwkoop, C.; de Boer, M. J. G.; Jolink, H.; den Hollander, J. G.; Pogany, K.; Bronsveld, W.; Kortmann, W.; van Twillert, G.; van Houte, D. P. F.; Polée, M. B.; van Vonderen, M. G. A.; ten Napel, C. H. H.; Kootstra, G. J.; Brinkman, K.; Blok, W. L.; Frissen, P. H. J.; Schouten, W. E. M.; van den Berk, G. E. L.; Juttmann, J. R.; van Kasteren, M. E. E.; Brouwer, A. E.; Mulder, J. W.; van Gorp, E. C. M.; Smit, P. M.; Weijer, S.; van Eeden, A.; Verhagen, D. W. M.; Sprenger, H. G.; Doedens, R.; Scholvinck, E. H.; van Assen, S.; Stek, C. J.; Hoepelman, I. M.; Mudrikova, T.; Schneider, M. M. E.; Jaspers, C. A. J. J.; Ellerbroek, P. M.; Peters, E. J. G.; Maarschalk-Ellerbroek, L. J.; Oosterheert, J. J.; Arends, J. E.; Wassenberg, M. W. M.; van der Hilst, J. C. H.; Richter, C.; van der Berg, J. P.; Gisolf, E. H.; Margolick, Joseph B.; Plankey, Michael; Crain, Barbara; Dobs, Adrian; Farzadegan, Homayoon; Gallant, Joel; Johnson-Hill, Lisette; Sacktor, Ned; Selnes, Ola; Shepard, James; Thio, Chloe; Phair, John P.; Wolinsky, Steven M.; Badri, Sheila; Conover, Craig; O'Gorman, Maurice; Ostrow, David; Palella, Frank; Ragin, Ann; Detels, Roger; Martínez-Maza, Otoniel; Aronow, Aaron; Bolan, Robert; Breen, Elizabeth; Butch, Anthony; Fahey, John; Jamieson, Beth; Miller, Eric N.; Oishi, John; Vinters, Harry; Visscher, Barbara R.; Wiley, Dorothy; Witt, Mallory; Yang, Otto; Young, Stephen; Zhang, Zuo Feng; Rinaldo, Charles R.; Becker, James T.; Cranston, Ross D.; Martinson, Jeremy J.; Mellors, John W.; Silvestre, Anthony J.; Stall, Ronald D.; Muñoz, Alvaro; Abraham, Alison; Althoff, Keri; Cox, Christopher; D'Souza, Gypsyamber; Gange, Stephen J.; Golub, Elizabeth; Schollenberger, Janet; Seaberg, Eric C.; Su, Sol; Huebner, Robin E.; Dominguez, Geraldina; Moroni, M.; Angarano, G.; Antinori, A.; Carosi, G.; Cauda, R.; Monforte, A. d'Arminio; Di Perri, G.; Galli, M.; Iardino, R.; Ippolito, G.; Lazzarin, A.; Perno, C. F.; Sagnelli, E.; Viale, P. L.; Von Schlosser, F.; d'Arminio Monforte, A.; Ammassari, A.; Andreoni, M.; Balotta, C.; Bonfanti, P.; Bonora, S.; Borderi, M.; Capobianchi, M. R.; Castagna, A.; Ceccherini-Silberstein, F.; Cozzi-Lepri, A.; de Luca, A.; Gargiulo, M.; Gervasoni, C.; Girardi, E.; Lichtner, M.; Lo Caputo, S.; Madeddu, G.; Maggiolo, F.; Marcotullio, S.; Monno, L.; Murri, R.; Mussini, C.; Puoti, M.; Torti, C.; Fanti, I.; Formenti, T.; Galli, Laura; Lorenzini, Patrizia; Montroni, M.; Giacometti, A.; Costantini, A.; Riva, A.; Tirelli, U.; Martellotta, F.; Ladisa, N.; Lazzari, G.; Verucchi, G.; Castelli, F.; Scalzini, A.; Minardi, C.; Bertelli, D.; Quirino, T.; Abeli, C.; Manconi, P. E.; Piano, P.; Vecchiet, J.; Falasca, K.; Carnevale, G.; Lorenzotti, S.; Sighinolfi, L.; Segala, D.; Leoncini, F.; Mazzotta, F.; Pozzi, M.; Cassola, G.; Viscoli, G.; Viscoli, A.; Piscopo, R.; Mazzarello, G.; Mastroianni, C.; Belvisi, V.; Caramma, I.; Chiodera, A.; Castelli, P.; Rizzardini, G.; Ridolfo, A. L.; Foschi, A.; Salpietro, S.; Galli, A.; Bigoloni, A.; Spagnuolo, V.; Merli, S.; Carenzi, L.; Moioli, M. C.; Cicconi, P.; Bisio, L.; Gori, A.; Lapadula, G.; Abrescia, N.; Chirianni, A.; de Marco, M.; Ferrari, C.; Borghi, R.; Baldelli, F.; Belfiori, B.; Parruti, G.; Ursini, T.; Magnani, G.; Ursitti, M. A.; Narciso, P.; Tozzi, V.; Vullo, V.; d'Avino, A.; Zaccarelli, M.; Gallo, L.; Acinapura, R.; Capozzi, M.; Libertone, R.; Trotta, M. P.; Tebano, G.; Cattelan, A. M.; Mura, M. S.; Caramello, P.; Orofino, G. C.; Sciandra, M.; Raise, N. N.; Ebo, F.; Pellizzer, G.; Manfrin, V.; Law, M.; Petoumenos, K.; McManus, H.; Wright, S.; Bendall, C.; Moore, R.; Edwards, S.

    2013-01-01

    Persons infected with human immunodeficiency virus (HIV) have increased rates of coronary artery disease (CAD). The relative contribution of genetic background, HIV-related factors, antiretroviral medications, and traditional risk factors to CAD has not been fully evaluated in the setting of HIV

  11. Traditional risk factors as determinants of heart rate recovery in patients with diabetes mellitus type 2 without known coronary artery disease

    Science.gov (United States)

    Silaban, Sanny; Afif Siregar, A.; Hasan, H.; Aryfa Andra, C.

    2018-03-01

    The impact of Traditional risk factors on heart rate recovery (HRR) has not been studied in patients Diabetes Mellitus type 2 without known coronary artery disease (CAD). For this reason, we sought to determine the association between HRR as cardiac autonomic dysfunction marker and traditonal risk factors. The study was conducted with a cross-sectional study involving 89 patients with Type 2 Diabetes Mellitus without known having coronary artery disease. The data was taken through anamnese and laboratory tests, and subjects who met the criteria were tested for a treadmill exercise to assess heart rate recovery in the first minute. In bivariate analysis Dyslipidemia, Hypertension, smoker, age, duration of DM≥ 5 years, HbA1C ≥7.5, Peak Heart rate, functional capacity and ST depression ischemic have an association with heart rate recovery. In multivariate analysis patients with hyper triglyceride, smoker, overweight, duration of diabetes ≥ five years and HbA1C ≥ 7,5 have lower heart rate recovery significantly. Traditional risk factors are determinant factors for heart rate recovery in patients with Diabetes Mellitus type 2 without known coronary artery disease.

  12. Enzimas miocárdicas na cirurgia de revascularização sem circulação extracorpórea Myocardial enzymes in off-pump CABG surgery

    Directory of Open Access Journals (Sweden)

    Paulo Roberto SOLTOSKI

    2000-06-01

    Full Text Available INTRODUÇÃO: A cirurgia cardíaca com o coração batendo está sendo cada vez mais utilizada para minimizar danos cerebrais, renais e outros. Porém, a incidência de infarto nos períodos per e pós-operatório e seu efeito a longo prazo, especialmente quando esta técnica é comparada às tradicionais, ainda não foi totalmente esclarecida. CASUÍSTICA E MÉTODOS: Um estudo retrospectivo de 303 pacientes (122 sem CEC, 181 com CEC foi realizado de fevereiro/97 a fevereiro/99. Dosagens de CK-MB e eletrocardiogramas foram avaliados nos períodos per e pós-operatório, troponina T (TnT foi medida no período pós-operatório. Os dois grupos foram comparáveis quanto a idade (65 ± 10 anos vs. 65 ± 9 anos, classificações CCS e NYHA. RESULTADOS: O número médio de enxertos com CEC foi de 3,10 vs. 2,26 sem CE. Infarto peri-operatório, assim como morbidade e mortalidade (7/181 vs. 6/122 foram comparáveis. Apesar de mais elevados no grupo com CEC, os níveis pós-operatórios de CK-MB e troponina T não atingiram diferença estatística, tendo sido observados 21 infartos agudos por critérios bioquímicos que se distribuíram igualmente entre os grupos. Uma correlação inversa entre o número de enxertos e a liberação de troponina foi observada na fase inicial da nossa experiência sem CEC. Não houve relação entre a localização do enxerto e a incidência de infarto ou liberação de troponina. CONCLUSÃO: A proteção miocárdica, morbidade e mortalidade obtidas com as duas técnicas de revascularização estudadas foram semelhantes. Considerando os efeitos adversos da CEC, já documentados na literatura, particularmente sobre os sistemas neurológico, respiratório e renal sugerimos esta técnica como uma alternativa segura para a revascularização miocárdica.BACKGROUND: CABG surgery on the beating heart (off-pump is increasingly used to lessen injury to the brain, kidneys and other organs. However, the perioperative incidence of

  13. Nuclear DNA as Predictor of Acute Kidney Injury in Patients Undergoing Coronary Artery Bypass Graft: A Pilot Study.

    Science.gov (United States)

    Likhvantsev, Valery V; Landoni, Giovanni; Grebenchikov, Oleg A; Skripkin, Yuri V; Zabelina, Tatiana S; Zinovkina, Liudmila A; Prikhodko, Anastasia S; Lomivorotov, Vladimir V; Zinovkin, Roman A

    2017-12-01

    To measure the release of plasma nuclear deoxyribonucleic acid (DNA) and to assess the relationship between nuclear DNA level and acute kidney injury occurrence in patients undergoing cardiac surgery. Cardiovascular anesthesiology and intensive care unit of a large tertiary-care university hospital. Prospective observational study. Fifty adult patients undergoing cardiac surgery. Nuclear DNA concentration was measured in the plasma. The relationship between the level of nuclear DNA and the incidence of acute kidney injury after coronary artery bypass grafting was investigated. Cardiac surgery leads to significant increase in plasma nuclear DNA with peak levels 12 hours after surgery (median [interquartile range] 7.0 [9.6-22.5] µg/mL). No difference was observed between off-pump and on-pump surgical techniques. Nuclear DNA was the only predictor of acute kidney injury between baseline and early postoperative risk factors. The authors found an increase of nuclear DNA in the plasma of patients who had undergone coronary artery bypass grafting, with a peak after 12 hours and an association of nuclear DNA with postoperative acute kidney injury. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. High-Risk Coronary Plaques Complicated with Acute Coronary Syndrome in Young Patients

    Directory of Open Access Journals (Sweden)

    Opincariu Diana

    2017-06-01

    Full Text Available Coronary computed tomography angiography (CCTA has evolved notably over the last decade, gaining an increased amount of temporo-spatial resolution in combination with decreased radiation exposure. The importance of CCTA is emerging especially in vulnerable and young patients who might not have developed a viable collateral vascular network to sustain the circulation to an infarction area during a major adverse coronary event. There are a few well-known markers by which a vulnerable plaque can be assessed and that can predict the subsequent events of sudden myocardial ischemia, such as an increased positive remodeling index (cut-off >1.4, low-attenuation plaque (cut-off 0.7, and napkin-ring sign (NRS. This manuscript presents a series of 3 clinical cases of young patients experiencing symptoms and signs of myocardial ischemia who underwent CCTA in order to assess the composition and functional characteristics of atherosclerotic plaques and their repercussion in developing an acute coronary syndrome.

  15. An Experiment on Heat Recovery Performance Improvements in Well-Water Heat-Pump Systems for a Traditional Japanese House

    Directory of Open Access Journals (Sweden)

    Chiemi Iba

    2018-04-01

    Full Text Available Concerns about resource depletion have prompted several countries to promote the usage of renewable energy, such as underground heat. In Japan, underground heat-pump technology has begun to be utilized in large-scale office buildings; however, several economic problems are observed to still exist, such as high initial costs that include drilling requirements. Further, most of the traditional dwellings “Kyo-machiya” in Kyoto, Japan have a shallow well. This study intends to propose an effective ground-source heat-pump system using the well water from a “Kyo-machiya” home that does not contain any drilling works. In previous research, it was depicted that the well-water temperature decreases as the heat pump (HP is operated and that the heat extraction efficiency steadily becomes lower. In this study, an experiment is conducted to improve efficiency using a drainage pump. Based on the experimental results, the effect of efficiency improvement and the increase in the electric power consumption of the drainage pump are examined. It is indicated that short-time drainage could help to improve efficiency without consuming excessive energy. Thus, continuous use of the heat pump becomes possible.

  16. Differences in traditional and non-traditional risk factors with special reference to nutritional factors in patients with coronary artery disease with or without diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Namita P Mahalle

    2013-01-01

    Full Text Available Introduction: There is an increase in awareness about the role of nutritional factors in chronic non-communicable diseases. We therefore conducted this study with an aim to assess the relationship between nutritional factor (vitamin B12 and homocysteine [Hcy] and its association with insulin resistance and inflammatory markers, and differences in traditional and non-traditional risk factors among diabetics and non-diabetics in known cases of coronary artery disease (CAD. Materials and Methods: Three hundred consecutive patients with known coronary disease on coronary angiography, who were >25 years old were included in this study. All cases were interviewed using a questionnaire. Blood samples were analyzed for insulin, vitamin B12, Hcy and inflammatory markers (highly sensitive C-reactive protein [hsCRP], interleukin-6 [IL-6], Tumor necrosis factor-alfa [TNF-α]. Insulin resistance was calculated with homeostasis model assessment of insulin resistance (HOMA-IR. Results: Mean age of the patients was 60.95 ± 12.3 years. Body mass index and waist hip ratio were comparable in both groups. Triglyceride, very low-density lipoprotein and HbA1C were significantly higher and high-density lipoprotein (HDL was significantly lower in patients with diabetes. Patients with diabetes had significantly high levels of IL-6, hsCRP and TNF-α compared with non-diabetic patients. Insulin resistance was twofold higher in diabetic patients. Serum vitamin B12 levels were significantly lower and Hcy was significantly higher in the diabetic group compared with the non-diabetic patients. HbA1C, HOMA-IR and Hcy levels were positively correlated with inflammatory markers in the total study population and in the non-diabetic patients; but, in diabetic patients, HbA1C and Hcy showed this relation. Conclusions: Vitamin B12 deficiency is common in the diabetic population. Hcy levels were higher in diabetics compared with non-diabetics, and were related to glycemic level and

  17. Cirurgia coronária com condutos arteriais múltiplos sem circulação extracorpórea Off-pump coronary artery bypass with multiple arterial conduits

    Directory of Open Access Journals (Sweden)

    Daniel Navia

    2005-03-01

    circulação extracorpórea utilizando condutos arteriais para a doença de múltiplos vasos é factível com baixa morbimortalidade em 30 dias.OBJECTIVE: To analyze intra-hospital results in patients undergoing elective off-pump total arterial revascularization and identify morbidity and mortality predictors using this surgical strategy. METHOD: From May 1999 to February 2004, 203 myocardial revascularization procedures with total arterial revascularization without cardiopulmonary bypass (off-pump were carried out in patients with multivessel disease (three vessels 81.7 %, one vessel disease was excluded. We report pre-surgical variables and co-morbidities: average age 63.9 ± 9.13 years, men 182 (89.5%, hypertension 132 (65%, smokers 125 (61%, hypercholesterolemia 152 (74.8%, previous myocardial infarction (> 30 days 73 (35%, moderate to severe ventricular dysfunction 31 (15%, redo five (2.5%. Total arterial revascularization included T-grafts and sequential grafts with left internal mammary (100%, right internal mammary (56.6% and radial (63% arteries. The total number of distal anastomosis was 576 (mean of three grafts/patient, all carried out with external mechanical stabilizers. There were no proximal aortic anastomoses. Conversion to on-pump surgery occurred in three (1.5% patients; 90% of the patients was extubated in the operating room. The multiple logistic regression test was used for statistical analysis. RESULTS: The postoperative incidence of atrial fibrillation was 12.8% (26, oligoanuric renal failure 3% (six, dialysis 0.49% (one, postoperative myocardial infarction 1.47% (three, low cardiac output 4% (eight, Redo for bleeding 1.47% (three, mediastinitis 1.47% (three, stroke 1.47% (three. Intra-hospital mortality was 2.45% (five. The only independent 30 day morbidity predictor was age (p=0.033; OR 1.04; IC 95%: 1-1.08. CONCLUSION: Off-pump myocardial revascularization with arterial conduits for multiple vessel disease is feasible with a low 30-day morbidity

  18. Process review of a departmental change from conventional coronary artery bypass grafting to totally arterial coronary artery bypass and its effects on the incidence and severity of postoperative stroke.

    Science.gov (United States)

    Albert, Alexander; Sergeant, Paul; Florath, Ines; Ismael, Mohammed; Rosendahl, Ulrich; Ennker, Jürgen

    2011-04-01

    We evaluated the process of changing from conventional coronary artery bypass grafting (CABG) to totally arterial off-pump coronary artery bypass (TOPCAB) at a single heart center in Germany. We (1) used multivariate statistical methods to assess real-time monitoring of OPCAB effects, (2) conducted a case review to assess preventable deaths and identify areas of improvement, (3) conducted a team survey, and (4) evaluated benchmarking results. All surgeons and assistants (n = 18) at this center were involved and were guided by the department head and one of the consultants, who was trained in this procedure in 2004 at the Leuven OPCAB school. The frequency of OPCAB operations increased abruptly in 2005 from 5% to 43% and then increased gradually to 67% (n = 546) by 2008 (total, 1781 OPCAB cases and 1563 on-pump cases). The in-hospital and 30-day mortality rates for OPCAB surgeries (n = 10 [0.6%] and 21 [1.2%], respectively) were lower than for on-pump surgeries (n = 27 [1.7%] and 26 [1.7%], respectively). Stroke rates were also lower for OPCAB surgeries (7 cases [0.4%] versus 15 cases [1%]). The lower risk of stroke in the OPCAB group was significant (P popularity, and a top national rank). The change from conventional CABG to TOPCAB was effective in decreasing the incidence and severity of stroke, in developing a team routine and a positive team attitude, and in producing excellent benchmarking results. The presence of a training and communication deficiency at the beginning of the study suggested an area for further improvement. After 6 years TOPCAB had largely replaced conventional CABG.

  19. Investigating the adaptability of the multi-pump multi-piston power take-off system for a novel wave energy converter

    NARCIS (Netherlands)

    Wei, Y.; Barradas Berglind, J.J; van Rooij, M.; Prins, WA; Jayawardhana, B.; Vakis, A. I.

    2017-01-01

    In this work, a numerical model is developed in order to investigate the adaptability of the multi-pump multi-piston power take-off ((MPPTO)-P-2) system of a novel wave energy converter (WEC). This model is realized in the MATLAB/SIMULINK environment, using the multi-body dynamics solver Multibody

  20. Effect of different dosages of nitroglycerin infusion on arterial blood gas tensions in patients undergoing on- pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Masoumi, Gholamreza; Pour, Evaz Hidar; Sadeghpour, Ali; Ziayeefard, Mohsen; Alavi, Mostapha; Anbardan, Sanam Javid; Shirani, Shahin

    2012-02-01

    On-pump coronary artery bypass graft (CABG) surgery impairs gas exchange in the early postoperative period. The main object on this study was evaluation of changes in arterial blood gas values in patients underwent on pump CABG surgery receiving different dose of intravenous nitroglycerin (NTG). sixty-seven consecutive patients undergoing elective on-pump CABG randomly enrolled into three groups receiving NTG 50 μg/min (Group N1, n =67), 100 μg/min (Group N2, n = 67), and 150 μg/min (Group N3, n = 67). Arterial blood gas (ABG) tensions were evaluated just before induction of anesthesia, during anesthesia, at the end of warming up period, and 6 h after admission to the intensive care unit. Pao2 and PH had the highest value during surgery in Group N1, Group N2, and Group N3. No significant difference was noted in mean values of Pao2 and PH during surgery between three groups (P > 0.05). There was no significant difference in HCO3 values in different time intervals among three groups (P > 0.05). our results showed that infusing three different dosage of NTG (50, 100, and 150 μg/min) had no significant effect on ABG tensions in patients underwent on-pump CABG surgery.

  1. Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Dewey, Marc; Hamm, Bernd

    2007-01-01

    We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of EUR4,435 (10% likelihood) to EUR1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society. (orig.)

  2. Pumping life

    DEFF Research Database (Denmark)

    Sitsel, Oleg; Dach, Ingrid; Hoffmann, Robert Daniel

    2012-01-01

    The name PUMPKIN may suggest a research centre focused on American Halloween traditions or the investigation of the growth of vegetables – however this would be misleading. Researchers at PUMPKIN, short for Centre for Membrane Pumps in Cells and Disease, are in fact interested in a large family o......’. Here we illustrate that the pumping of ions means nothing less than the pumping of life....

  3. Surgery of abdominal aortic aneurysm associated with coronary artery disease. Simultaneous or two staged operation

    International Nuclear Information System (INIS)

    Tanaka, Hiroyuki; Narisawa, Takashi; Mori, Takanobu; Masuda, Mikio; Kishi, Daijirou; Suzuki, Takashi; Takaba, Toshihiro

    2003-01-01

    Coronary artery disease (CAD) was evaluated by noninvasive examination in abdominal aortic aneurysm (AAA) patients. A simultaneous operation or a 2-staged operation was performed depending on the seriousness of the condition when both diseases were combined. A total of 36 patients underwent elective repair of AAA between 1996 and 2001. Coronary angiography (CAG) was performed only in patients with suspected CAD by dipyridamole myocardial scintigraphy. Significant CAD was found in 8 patients. Simultaneous operation was performed in 4 patients, and off-pump coronary artery bypass grafting (OPCAB) was performed in all cases of simultaneous operation. In 4 patients receiving 2-staged operations, 1 standard coronary artery bypass grafting (CABG), 1 OPCAB and 2 percutaneous transluminal coronary angioplasties (PTCA) were performed prior to AAA surgery. Twenty-eight patients underwent only AAA operation. Though there were no incidents of perioperative myocardial infarction or cardiac related deaths in this group, 2 patients died due to other causes (hemorrhage and duodenal perforation). In the 8 patients associated with CAD, 1 patient died of myonephrotic metabolic syndrome (MNMS) after simultaneous operation. The other 7 patients revived their social function soon of the discharge. Dipyridamole cardiac scintigraphy was considered to be an effective examination for evaluation of CAD in AAA patients. There was no need to perform CAG in all AAA patients. The policy of choosing simultaneous operation or 2-staged operation according to the seriousness of the 2 diseases seemed to be appropriate. (author)

  4. Numerical study on the selective excitation of Helmholtz-Gauss beams in end-pumped solid-state digital lasers with the control of the laser gain transverse position provided by off-axis end pumping

    Science.gov (United States)

    Tsai, Ko-Fan; Chu, Shu-Chun

    2018-03-01

    This study proposes a complete and unified method for selective excitation of any specified nearly nondiffracting Helmholtz-Gauss (HzG) beam in end-pumped solid-state digital lasers. Four types of the HzG beams: cosine-Gauss beams, Bessel-Gauss beams, Mathieu-Gauss beams, and, in particular, parabolic-Gauss beams are successfully demonstrated to be generated with the proposed methods. To the best of the authors’ knowledge, parabolic-Gauss beams have not yet been directly generated from any kind of laser system. The numerical results of this study show that one can successfully achieve any lasing HzG beams directly from the solid-state digital lasers with only added control of the laser gain transverse position provided by off-axis end pumping. This study also presents a practical digital laser set-up for easily manipulating off-axis pumping in order to achieve the control of the laser gain transverse gain position in digital lasers. The reported results in this study provide advancement of digital lasers in dynamically generating nondiffracting beams. The control of the digital laser cavity gain position creates the possibility of achieving real-time selection of more laser modes in digital lasers, and it is worth further investigation in the future.

  5. Urgent Coronary Artery Bypass Surgery in a Patient with Postinfarction Angina and Active Myelomonocytic Leukaemia

    Directory of Open Access Journals (Sweden)

    Samuel Anthony Galea

    2016-11-01

    Full Text Available Chronic myelomonocytic leukaemia (CMML is a myelodysplastic/myeloproliferative neoplasm affecting the production and differentiation of the monocyte cell lineage. Cardiac surgery in the context of CMML poses challenges that are not routinely encountered. This is the first reported case in the literature of a patient with active CMML undergoing urgent on-pump coronary artery bypass grafting. A 68-year-old Caucasian man with a history of hypertension, hyperlipidaemia, hypothyroidism, and hypercholesterolaemia, who had been diagnosed by the haematologists with CMML a few months earlier but had remained untreated, underwent urgent surgical coronary revascularisation because of postinfarction angina following a non-ST elevation myocardial infarction associated with troponin I rise. The patient had fulminant postoperative myelomonocytic leukaemoid reaction, with a clinical picture of severe systemic inflammatory response syndrome and multiple organ dysfunction syndrome. This led to extensive vasodilation and heart failure that resulted in the death of the patient. Various authors have suggested different techniques and treatment options, each attempting to mitigate the effect of the postoperative inflammatory response. However, this is a high-risk endeavour with a myriad of inflammatory signals mobilised into action because of the surgical insult. Off-pump surgery or preoperative pharmacological attenuation of CMML activity might have dampened this response and resulted in a positive outcome for the patient.

  6. Risks of on-pump coronary artery bypass grafting surgery in patients with chronic obstructive pulmonary disease due to sulfur mustard.

    Science.gov (United States)

    Firoozabadi, Mehdi Dehghani; Sheikhi, Mohammad Ali; Rahmani, Hossein; Ebadi, Ahmad; Heidari, Amanollah; Gholizadeh, Behnam; Sharifi, Khosrow

    2017-10-01

    Sulfur mustard (SM) is a toxic chemical agent that belongs to a class of vesicant compounds. In the 1980s it was used by the Iraqi army against Iranian forces. Sulfur mustard severely irritates the skin, eyes and lungs. The highest side effects seen in patients affected by this gas are pulmonary complications including different types of lung diseases such as bronchiolitis. It has also led to a certain type of chronic obstructive pulmonary disease called mustard lung. Similar extra-pulmonary, molecular and hormonal effects can be observed in these patients and patients with chronic obstructive pulmonary disease. Here cardiovascular complications may be one of the most dangerous visible effects. And atherosclerosis is probable following the direct effects or consequential long-term effects of SM. The development of atherosclerosis in these patients is associated with an increased risk of cardiovascular and coronary artery disease. Coronary artery bypass grafting surgery is the treatment of coronary artery disease. Doing this surgery by bypass pump has its own morbidity and due to local and systemic inflammation changes in patients with SM pulmonary disorders it may have more side effects. Therefore, detailed knowledge of inflammatory diseases as well as the serum level or even the local lung fluid of the inflammatory factors in these patients before surgery are needed so that it would be possible to reduce the rate of morbidity and mortality by normalizing the inflammatory conditions of the patients before cardiac surgery.

  7. Predictors of cardiogenic shock in cardiac surgery patients receiving intra-aortic balloon pumps.

    Science.gov (United States)

    Iyengar, Amit; Kwon, Oh Jin; Bailey, Katherine L; Ashfaq, Adeel; Abdelkarim, Ayman; Shemin, Richard J; Benharash, Peyman

    2018-02-01

    Cardiogenic shock after cardiac surgery leads to severely increased mortality. Intra-aortic balloon pumps may be used during the preoperative period to increase coronary perfusion. The purpose of this study was to characterize predictors of postoperative cardiogenic shock in cardiac surgery patients with and without intra-aortic balloon pumps support. We performed a retrospective analysis of our institutional database of the Society of Thoracic Surgeons for patients operated between January 2008 to July 2015. Multivariable logistic regression was used to model postoperative cardiogenic shock in both the intra-aortic balloon pumps and matched control cohorts. Overall, 4,741 cardiac surgery patients were identified during the study period, of whom 192 (4%) received a preoperative intra-aortic balloon pump. Intra-aortic balloon pumps patients had a greater prevalence of diabetes, previous cardiac surgery, congestive heart failure, and an urgent/emergent status (P pumps patients also had greater 30-day mortality and more postoperative cardiogenic shock (9% vs 3%, P pumps cohort, only sex, previous percutaneous coronary intervention and preoperative arrhythmia remained significant on multivariable analysis (all P pumps and those who do not. Further analysis of the effects of prophylactic intra-aortic balloon pumps support is warranted. (Surgery 2017;160:XXX-XXX.). Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery

    OpenAIRE

    Maimaituxun, Gulinu; Shimabukuro, Michio; Salim, Hotimah Masdan; Tabata, Minoru; Yuji, Daisuke; Morimoto, Yoshihisa; Akasaka, Takeshi; Matsuura, Tomomi; Yagi, Shusuke; Fukuda, Daiju; Yamada, Hirotsugu; Soeki, Takeshi; Sugimoto, Takaki; Tanaka, Masashi; Takanashi, Shuichiro

    2017-01-01

    Background Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD) are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV) in patients undergoing coronary artery bypass grafting (CABG) remains unknown. Methods Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57) who underwent CABG or non-coronary valvular surgery ...

  9. Study of perioperative extravascular lung water and intrathoracic blood volume in patients undergoing CABG surgery with or without cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Samia Ragab El Azab

    2014-10-01

    Discussion and Conclusion: The clinical advantage of off-pump CABG surgery over standard extracorporeal circulation in regard to lung water content was not found in our study. In conclusion, the presumed superiority of off pump surgery for coronary artery bypass grafting could not be confirmed in our group of patients.

  10. Dynamic interaction between myocardial contraction and coronary flow.

    Science.gov (United States)

    Beyar, R; Sideman, S

    1997-01-01

    Phasic coronary flow is determined by the dynamic interaction between central hemodynamics and myocardial and ventricular mechanics. Various models, including the waterfall, intramyocardial pump and myocardial structural models, have been proposed for the coronary circulation. Concepts such as intramyocardial pressure, local elastance and others have been proposed to help explain the coronary compression by the myocardium. Yet some questions remain unresolved, and a new model has recently been proposed, linking a muscle collagen fibrous model to a physiologically based coronary model, and accounting for transport of fluids across the capillaries and lymphatic flow between the interstitial space and the venous system. One of the unique features of this model is that the intramyocardial pressure (IMP) in the interstitial space is calculated from the balance of forces and fluid transport in the system, and is therefore dependent on the coronary pressure conditions, the myocardial function and the transport properties of the system. The model predicts a wide range of experimentally observed phenomena associated with coronary compression.

  11. Pumping behavior of ion pump elements at high and misaligned magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Hseuh, H. C.; Jiang, W. S.; Mapes, M.

    1994-11-01

    The pumping speeds of several diode type ion pump elements with cell radii of 5 mm, 5.5 mm, 6 mm, 9 mm and 12 mm were measured while being subjected to a magnetic field B, ranging from 500 Gauss up to 15 KG, and misalignment angles (angles between the direction of B and the anode axis) from 0 to 13 degrees. The pumping speeds of elements with the 9 mm and 12 mm cells peaked around 1--2 KG, then dropped off rapidly with an increasing magnetic field. The pumping speeds of the smaller cell elements remained constant with an increasing magnetic field. The pumping speeds of all the elements decreased with increasing misalignment. The measured pumping speeds from this study are 3--4 times lower than the calculated pumping, speeds using previously reported empirical formulae.

  12. Pumping behavior of ion pump elements at high and misaligned magnetic fields

    International Nuclear Information System (INIS)

    Hseuh, H.C.; Jiang, W.S.; Mapes, M.

    1994-01-01

    The pumping speeds of several diode type ion pump elements with cell radii of 5 mm, 5.5 mm, 6 mm, 9 mm and 12 mm were measured while being subjected to a magnetic field B, ranging from 500 Gauss up to 15 KG, and misalignment angles (angles between the direction of B and the anode axis) from 0 to 13 degrees. The pumping speeds of elements with the 9 mm and 12 mm cells peaked around 1--2 KG, then dropped off rapidly with an increasing magnetic field. The pumping speeds of the smaller cell elements remained constant with an increasing magnetic field. The pumping speeds of all the elements decreased with increasing misalignment. The measured pumping speeds from this study are 3--4 times lower than the calculated pumping, speeds using previously reported empirical formulae

  13. A first-in-man study of the Reitan catheter pump for circulatory support in patients undergoing high-risk percutaneous coronary intervention.

    Science.gov (United States)

    Smith, Elliot J; Reitan, Oyvind; Keeble, Thomas; Dixon, Kerry; Rothman, Martin T

    2009-06-01

    To investigate the safety of a novel percutaneous circulatory support device during high-risk percutaneous coronary intervention (PCI). The Reitan catheter pump (RCP) consists of a catheter-mounted pump-head with a foldable propeller and surrounding cage. Positioned in the descending aorta the pump creates a pressure gradient, reducing afterload and enhancing organ perfusion. Ten consecutive patients requiring circulatory support underwent PCI; mean age 71 +/- 9; LVEF 34% +/- 11%; jeopardy score 8 +/- 2.3. The RCP was inserted via the femoral artery. Hemostasis was achieved using Perclose sutures. PCI was performed via the radial artery. Outcomes included in-hospital death, MI, stroke, and vascular injury. Hemoglobin (Hb), free plasma Hb (fHb), platelets, and creatinine (cre) were measured pre PCI and post RCP removal. The pump was inserted and operated successfully in 9/10 cases (median 79 min). Propeller rotation at 10,444 +/- 1,424 rpm maintained an aortic gradient of 9.8 +/- 2 mm Hg. Although fHb increased, there was no significant hemolysis (4.7 +/- 2.4 mg/dl pre vs. 11.9 +/- 10.5 post, P = 0.04, reference 20 mg/dl). Platelets were unchanged (pre 257 +/- 74 x 10(9) vs. 245 +/- 63, P = NS). Renal function improved (cre pre 110 +/- 27 micromol/l vs. 99 +/- 28, P = 0.004). The RCP was not used in one patient following femoral introducer sheath related aortic dissection. All PCI procedures were successful with no deaths or strokes, one MI, and no vascular complications following pump removal. The RCP can be used safely in high-risk PCI patients. This device may be an alternative to other percutaneous systems when substantial cardiac support is needed. (c) 2009 Wiley-Liss, Inc.

  14. Pump efficiency in solar-energy systems

    Science.gov (United States)

    1978-01-01

    Study investigates characteristics of typical off-the-shelf pumping systems that might be used in solar systems. Report includes discussion of difficulties in predicting pump efficiency from manufacturers' data. Sample calculations are given. Peak efficiencies, flow-rate control, and noise levels are investigated. Review or theory of pumps types and operating characteristics is presented.

  15. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    OpenAIRE

    Guizilini, Solange; Bolzan, Douglas W; Faresin, Sonia M; Ferraz, Raquel F; Tavolaro, Kelly; Cancio, Andrea A; Gomes, Walter J

    2012-01-01

    Abstract Background Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary f...

  16. Effects of exercise training on coronary transport capacity

    International Nuclear Information System (INIS)

    Laughlin, M.H.

    1985-01-01

    Coronary transport capacity was estimated in eight sedentary control and eight exercise-trained anesthetized dogs by determining the differences between base line and the highest coronary blood flow and permeability-surface area product (PS) obtained during maximal adenosine vasodilation with coronary perfusion pressure constant. The anterior descending branch of the left coronary artery was cannulated and pump- perfused under constant-pressure conditions (approximately equal to 100 Torr) while aortic, central venous, and coronary perfusion pressures, heart rate, electrocardiogram, and coronary flow were monitored. Myocardial extraction and PS of 51 Cr-labeled ethylenediaminetetraacetic acid were determined with the single-injection indicator-diffusion method. The efficacy of the 16 +/- 1 wk exercise training program was shown by significant increases in the succinate dehydrogenase activities of the gastrocnemius, gluteus medialis, and long head of triceps brachii muscles. There were no differences between control and trained dogs for either resting coronary blood flow or PS. During maximal vasodilation with adenosine, the trained dogs had significantly lower perfusion pressures with constant flow and, with constant-pressure vasodilation, greater coronary blood flow and PS. It is concluded that exercise training in dogs induces an increased coronary transport capacity that includes increases in coronary blood flow capacity (26% of control) and capillary diffusion capacity (82% of control)

  17. Non-obstructive low attenuation coronary plaque predicts three-year acute coronary syndrome events in patients with hypertension. Multidetector computed tomographic study

    International Nuclear Information System (INIS)

    Nakanishi, Koki; Shimada, Kenei; Fukuda, Shota

    2012-01-01

    Arterial hypertension is an established risk factor for acute coronary syndrome (ACS). Multidetector computed tomography (MDCT) is an accurate and less invasive technique for assessment of the degree of coronary artery luminal narrowing and characterization of coronary atherosclerosis. We therefore aimed to investigate the predictive power of MDCT for future ACS events and compared with traditional parameters in patients with hypertension. One hundred and thirty-four patients (93 men, mean age 70±11 years) with hypertension underwent MDCT for evaluation of coronary artery disease. MDCT analysis focused on the presence of plaques, the degree of stenosis, and the plaque characteristics. Traditional parameters included Framingham risk score, carotid intima-media thickness, and left ventricular mass index. During a mean follow-up of 39±10 months, ACS events occurred in 10 patients, including myocardial infarction (n=3) and unstable angina (n=7). Multivariate analysis identified total number of low attenuation plaques as an independent predictor of ACS events (p<0.001). We demonstrated that non-obstructive low attenuation coronary plaques on MDCT predicted more accurately future ACS events in patients with hypertension than traditional parameters. (author)

  18. Study of Stage-wise Pressure Pulsation in an Electric Submersible Pump under Variable Frequency Operation at Shut-off Condition

    Science.gov (United States)

    Dhanasekaran, A.; Kumaraswamy, S.

    2018-01-01

    Pressure pulsation causes vibration in the Electric Submersible Pump (ESP) and affects the life and performance of its system. ESP systems are installed at depths ranging from a few meters to several hundred meters. Unlike pumps used on the surface, once they are installed they become inaccessible for maintenance or for any kind of diagnostic measurement that might be taken directly on them. Therefore a detailed knowledge of mean and fluctuating pressures is required to achieve an optimal pressure distribution inside the ESP. This paper presents the results of an experimental investigation of the stage-wise pulsating pressure in ESP at shut-off condition at different speeds. Experiments were conducted on a pump having five stages. A variable frequency drive was used to operate the pump at five different speeds. Piezoresistive transducers were mounted at each stage of ESP to capture the unsteady pressure signals. Fast Fourier Transformation was carried out on the pressure signals to convert into frequency domain and the spectra of pressure pulsation signals were analyzed. The obtained results indicated the existence of fundamental frequency corresponding to the speed of rotation times the number of impeller blades and of the whole series of harmonics of higher frequencies.

  19. Pericardial and thoracic peri-aortic adipose tissues contribute to systemic inflammation and calcified coronary atherosclerosis independent of body fat composition, anthropometric measures and traditional cardiovascular risks

    International Nuclear Information System (INIS)

    Yun, Chun-Ho; Lin, Tin-Yu; Wu, Yih-Jer; Liu, Chuan-Chuan; Kuo, Jen-Yuan; Yeh, Hung-I.; Yang, Fei-Shih; Chen, Su-Chiu; Hou, Charles Jia-Yin; Bezerra, Hiram G.; Hung, Chung-Lieh; Cury, Ricardo C.

    2012-01-01

    Background: Coronary atherosclerosis has traditionally been proposed to be associated with several cardiovascular risk factors and anthropometric measures. However, clinical data regarding the independent value of visceral adipose tissue in addition to such traditional predictors remains obscure. Materials and methods: We subsequently studied 719 subjects (age: 48.1 ± 8.3 years, 25% females) who underwent multidetector computed tomography (MDCT) for coronary calcium score (CCS) quantification. Baseline demographic data and anthropometric measures were taken with simultaneous body fat composition estimated. Visceral adipose tissue of pericardial and thoracic peri-aortic fat was quantified by MDCT using TeraRecon Aquarius workstation (San Mateo, CA). Traditional cardiovascular risk stratification was calculated by metabolic (NCEP ATP III) and Framingham (FRS) scores and high-sensitivity CRP (Hs-CRP) was taken to represent systemic inflammation. The independent value of visceral adipose tissue to systemic inflammation and CCS was assessed by utilizing multivariable regression analysis. Results: Of all subjects enrolled in this study, the mean values for pericardial and peri-aortic adipose tissue were 74.23 ± 27.51 and 7.23 ± 3.69 ml, respectively. Higher visceral fat quartile groups were associated with graded increase of risks for cardiovascular diseases. Both adipose burdens strongly correlated with anthropometric measures including waist circumference, body weight and body mass index (all p < 0.001). In addition, both visceral amount correlates well with ATP and FRS scores, all lipid profiles and systemic inflammation marker in terms of Hs-CRP (all p < 0.001). After adjustment for baseline variables, both visceral fat were independently related to Hs-CRP levels (all p < 0.05), but only pericardial fat exerted independent role in coronary calcium deposit. Conclusion: Both visceral adipose tissues strongly correlated with systemic inflammation beyond traditional

  20. Contribution of genetic background, traditional risk factors, and HIV-related factors to coronary artery disease events in HIV-positive persons

    OpenAIRE

    Rotger, Margalida; Glass, Tracy R; Junier, Thomas; Lundgren, Jens; Neaton, James D; Poloni, Estella S; van 't Wout, Angélique B; Lubomirov, Rubin; Colombo, Sara; Martinez, Raquel; Rauch, Andri; Günthard, Huldrych F; Neuhaus, Jacqueline; Wentworth, Deborah; van Manen, Danielle

    2013-01-01

    BACKGROUND: Persons infected with human immunodeficiency virus (HIV) have increased rates of coronary artery disease (CAD). The relative contribution of genetic background, HIV-related factors, antiretroviral medications, and traditional risk factors to CAD has not been fully evaluated in the setting of HIV infection. METHODS: In the general population, 23 common single-nucleotide polymorphisms (SNPs) were shown to be associated with CAD through genome-wide association analysis. Using the ...

  1. Re-evaluation of the traditional diet-heart hypothesis: analysis of recovered data from Minnesota Coronary Experiment (1968-73)

    Science.gov (United States)

    Zamora, Daisy; Majchrzak-Hong, Sharon; Faurot, Keturah R; Broste, Steven K; Frantz, Robert P; Davis, John M; Ringel, Amit; Suchindran, Chirayath M; Hibbeln, Joseph R

    2016-01-01

    Objective To examine the traditional diet-heart hypothesis through recovery and analysis of previously unpublished data from the Minnesota Coronary Experiment (MCE) and to put findings in the context of existing diet-heart randomized controlled trials through a systematic review and meta-analysis. Design The MCE (1968-73) is a double blind randomized controlled trial designed to test whether replacement of saturated fat with vegetable oil rich in linoleic acid reduces coronary heart disease and death by lowering serum cholesterol. Recovered MCE unpublished documents and raw data were analyzed according to hypotheses prespecified by original investigators. Further, a systematic review and meta-analyses of randomized controlled trials that lowered serum cholesterol by providing vegetable oil rich in linoleic acid in place of saturated fat without confounding by concomitant interventions was conducted. Setting One nursing home and six state mental hospitals in Minnesota, United States. Participants Unpublished documents with completed analyses for the randomized cohort of 9423 women and men aged 20-97; longitudinal data on serum cholesterol for the 2355 participants exposed to the study diets for a year or more; 149 completed autopsy files. Interventions Serum cholesterol lowering diet that replaced saturated fat with linoleic acid (from corn oil and corn oil polyunsaturated margarine). Control diet was high in saturated fat from animal fats, common margarines, and shortenings. Main outcome measures Death from all causes; association between changes in serum cholesterol and death; and coronary atherosclerosis and myocardial infarcts detected at autopsy. Results The intervention group had significant reduction in serum cholesterol compared with controls (mean change from baseline −13.8% v −1.0%; Pdiet with linoleic acid effectively lowers serum cholesterol but does not support the hypothesis that this translates to a lower risk of death from coronary heart

  2. Immediate extubation versus standard postoperative ventilation: Our experience in on pump open heart surgery

    Directory of Open Access Journals (Sweden)

    Srikanta Gangopadhyay

    2010-01-01

    Full Text Available Elective postoperative ventilation in patients undergoing "on pump" open heart surgery has been a standard practice. Ultra fast-track extubation in the operating room is now an accepted technique for "off pump" coronary artery bypass grafting. We tried to incorporate these experiences in on pump open heart surgery and compare the haemodynamic and respiratory parameters in the immediate postoperative period, in patients on standard postoperative ventilation for 8-12 hours. After ethical committee′s approval and informed consent were obtained, 72 patients, between 28 and 45 years of age, undergoing on pump open heart surgery, were selected for our study. We followed same standard anaesthetic, cardiopulmonary bypass (CPB and cardioplegic protocol. Thirty-six patients (Group E were randomly allocated for immediate extubation following operation, after fulfillment of standard extubation criteria. Those who failed to meet these criteria were not extubated and were excluded from the study. The remaining 36 patients (Group V were electively ventilated and extubated after 8-12 hours. Standard monitoring for on pump open heart surgery, including bispectral index was done. The demographic data, surgical procedures, preoperative parameters, aortic cross clamp and cardiopulmonary bypass times were comparable in both the groups. Extubation was possible in more than 88% of cases (n=32 out of 36 cases in Group E and none required reintubation for respiratory insufficiency. Respiratory, haemodynamic parameters and postoperative complications were comparable in both the groups in the postoperative period. Therefore, we can safely conclude that immediate extubation in the operating room after on pump open heart surgery is an alternative acceptable method to avoid postoperative ventilation and its related complications in selected patients.

  3. Use of Proton-Pump Inhibitors Predicts Heart Failure and Death in Patients with Coronary Artery Disease.

    Directory of Open Access Journals (Sweden)

    Ana María Pello Lázaro

    Full Text Available Proton-pump inhibitors (PPIs seem to increase the incidence of cardiovascular events in patients with coronary artery disease (CAD, mainly in those using clopidogrel. We analysed the impact of PPIs on the prognosis of patients with stable CAD.We followed 706 patients with CAD. Primary outcome was the combination of secondary outcomes. Secondary outcomes were 1 acute ischaemic events (any acute coronary syndrome, stroke, or transient ischaemic attack and 2 heart failure (HF or death.Patients on PPIs were older [62.0 (53.0-73.0 vs. 58.0 (50.0-70.0 years; p = 0.003] and had a more frequent history of stroke (4.9% vs. 1.1%; p = 0.004 than those from the non-PPI group, and presented no differences in any other clinical variable, including cardiovascular risk factors, ejection fraction, and therapy with aspirin and clopidogrel. Follow-up was 2.2±0.99 years. Seventy-eight patients met the primary outcome, 53 developed acute ischaemic events, and 33 HF or death. PPI use was an independent predictor of the primary outcome [hazard ratio (HR = 2.281 (1.244-4.183; p = 0.008], along with hypertension, body-mass index, glomerular filtration rate, atrial fibrillation, and nitrate use. PPI use was also an independent predictor of HF/death [HR = 5.713 (1.628-20.043; p = 0.007], but not of acute ischaemic events. A propensity score showed similar results.In patients with CAD, PPI use is independently associated with an increased incidence of HF and death but not with a high rate of acute ischaemic events. Further studies are needed to confirm these findings.

  4. Cardiovascular outcomes associated with concomitant use of clopidogrel and proton pump inhibitors in patients with acute coronary syndrome in Taiwan

    Science.gov (United States)

    Lin, Chen-Fang; Shen, Li-Jiuan; Wu, Fe-Lin Lin; Bai, Chyi-Huey; Gau, Churn-Shiouh

    2012-01-01

    AIMS Our study aimed to examine the impact of concomitant use of proton pump inhibitors (PPIs) with clopidogrel on the cardiovascular outcomes of patients with acute coronary syndrome (ACS). Furthermore, we sought to quantify the effects of five individual PPIs when used concomitantly with clopidogrel. METHODS We conducted a retrospective cohort study of patients who were newly hospitalized for ACS between 1 January 2006 and 31 December 2007 retrieved from the Taiwan National Health Insurance Research Database (NHIRD) and who were prescribed clopidogrel (n= 37 099) during the follow-up period. A propensity score technique was used to establish a matched cohort in 1:1 ratio (n= 5173 for each group). The primary clinical outcome was rehospitalization for ACS, while secondary outcomes were rehospitalization for percutaneous transluminal coronary angioplasty (PTCA) with stent, PTCA without stent and revascularization (PTCA or coronary artery bypass graft surgery) after the discharge date for the index ACS event. RESULTS The adjusted hazard ratio of rehospitalization for ACS was 1.052 (95% confidence interval, 0.971–1.139; P= 0.214) in the propensity score matched cohort. Among all PPIs, only omeprazole was found to be statistically significantly associated with an increased risk of rehospitalization for ACS (adjusted hazard ratio, 1.226; 95% confidence interval, 1.066–1.410; P= 0.004). Concomitant use of esomeprazole, pantoprazole, rabeprazole and lansoprazole did not increase the risk. CONCLUSIONS Our study indicated no statistically significant increase in the risk of rehospitalization for ACS due to concurrent use of clopidogrel and PPIs overall. Among individual PPIs, only omeprazole was found to be statistically significantly associated with increased risk of rehospitalization for ACS. PMID:22364155

  5. Traditional and non-traditional educational outcomes : Trade-off or complementarity?

    NARCIS (Netherlands)

    van der Wal, Marieke; Waslander, Sietske

    2007-01-01

    Recently, schools have increasingly been charged with enhancing non-traditional academic competencies, in addition to traditional academic competencies. This article raises the question whether schools can implement these new educational goals in their curricula and simultaneously realise the

  6. Residual heat removal pump and low pressure safety injection pump retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; McKenna, J.M.

    1992-01-01

    Residual Heat Removal (RHR) and low pressure safety injection (LPSI) pumps installed in pressurized water-to-reactor power plants are used to provide low-head safety injection in the event of loss of coolant in the reactor coolant system. Because these pumps are subjected to rather severe temperature and pressure transients, the majority of pumps installed in the RHR service are vertical pumps with a single stage impeller. Typically the pump impeller is mounted on an extended motor shaft (close-coupled configuration) and a mechanical seal is employed at the pump end of the shaft. Traditionally RHR and LPSI pumps have been a significant maintenance item for many utilities. Periodic mechanical seal of motor bearing replacement often is considered routine maintenance. The closed-coupled pump design requires disassembly of the casing cover from the lower pump casing while performing these routine maintenance tasks. This paper introduces a design modification developed to convert the close-coupled RHR and LPSI pumps to a coupled configuration

  7. Association of traditional cardiovascular risk factors with coronary plaque sub-types assessed by 64-slice computed tomography angiography in a large cohort of asymptomatic subjects.

    Science.gov (United States)

    Rivera, Juan J; Nasir, Khurram; Cox, Pedro R; Choi, Eue-Keun; Yoon, Yeonyee; Cho, Iksung; Chun, Eun-Ju; Choi, Sang-Il; Blumenthal, Roger S; Chang, Hyuk-Jae

    2009-10-01

    Although prior studies have shown that traditional cardiovascular (CV) risk factors are associated with the burden of coronary atherosclerosis, less is known about the relationship of risk factors with coronary plaque sub-types. Coronary computed tomography angiography (CCTA) allows an assessment of both, total disease burden and plaque characteristics. In this study, we investigate the relationship between traditional CV risk factors and the presence and extent of coronary plaque sub-types in a large group of asymptomatic individuals. The study population consisted of 1015 asymptomatic Korean subjects (53+/-10 years; 64% were males) free of known CV disease who underwent 64-slice CCTA as part of a health screening evaluation. We analyzed plaque characteristics on a per-segment basis according to the modified American Heart Association classification. Plaques in which calcified tissue occupied more than 50% of the plaque area were classified as calcified (CAP), NCAP). A total of 215 (21%) subjects had coronary plaque while 800 (79%) had no identifiable disease. Multivariate regression analysis demonstrated that increased age (per decade) and gender are the strongest predictors for the presence of any coronary plaque or the presence of at least one segment of CAP and MCAP (any plaque-age: OR 2.89; 95% CI 2.34, 3.56; male gender: OR 5.21; 95% CI 3.20, 8.49; CAP-age: OR 2.75; 95% CI 2.12, 3.58; male gender: 4.78; 95% CI 2.48, 9.23; MCAP-age: OR 2.62; 95% CI 2.02, 3.39; male gender: OR 4.15; 95% CI 2.17, 7.94). The strongest predictors for the presence of any NCAP were gender (OR 3.56; 95% CI 1.96-6.55) and diabetes mellitus (OR 2.87; 95% CI 1.63-5.08). When looking at the multivariate association between the presence of >/=2 coronary segments with a plaque sub-type and CV risk factors, male gender was the strongest predictor for CAP (OR 7.31; 95% CI 2.12, 25.20) and MCAP (OR 5.54; 95% CI 1.84, 16.68). Alternatively, smoking was the strongest predictor for the presence

  8. Severity of coronary artery disease in obese patients undergoing coronary angiography

    International Nuclear Information System (INIS)

    Javed, A.; Ali, J.; Kayani, A.M.

    2012-01-01

    Objective: To assess the relationship of severity of coronary artery disease with obesity in patients undergoing coronary angiography. Design: Cross sectional study. Place and Duration of Study: Armed Forces Institute of Cardiology - National Institute of Heart Diseases (AFIC-NIHD), 1st February 2010 to 31st August 2010 Patients and Methods: The study population included 468 patients undergoing coronary angiography. Obesity was classified according to the BMI using the National Institutes of Health (NIH) criteria as normal (BMI 21-24 kg/m2), overweight (BMI 25-29 kg/m2), obesity class I (BMI 30-34 kg/m2), obesity class II (BMI 35 to 39 kg/m2 and obesity class III (BMI 40 or above kg/m2). Coronary angiography data were obtained from the Siemens Queries software system, which maintains the database including detailed angiographic findings of all patients at this institution. Significant lesions were defined as those with >70% diameter narrowing of coronary arteries (>50% for the left main coronary artery). We attempted to quantify the 'severity of CAD' by ascertaining the prevalence of High-Risk Coronary Anatomy (HRCA). Results: Insignificant difference was observed in traditional risk factors i.e. age, diabetes mellitus and smoking except hypertension and gender. Statistically significantly low prevalence of HRCA was encountered in the obese group (57.7%) as compared to normal/overweight group (75.8%) (p < 0.05). Conclusion: We conclude that obesity is associated with less severe coronary artery disease. (author)

  9. Flow Rate In Microfluidic Pumps As A Function Of Tension and Pump Motor Head Speed

    Science.gov (United States)

    Irwin, Anthony; McBride, Krista

    2015-03-01

    As the use of microfluidic devices has become more common in recent years the need for standardization within the pump systems has grown. The pumps are ball bearing rotor microfluidic pumps and work off the idea of peristalsis. The rapid contraction and relaxation propagating down a tube or a microfluidic channel. The ball bearings compress the tube (occlusion) and move along part of the tube length forcing fluid to move inside of the tube in the same direction of the ball bearings. When the ball bearing rolls off the area occupied by the microfluidic channel, its walls and ceiling undergo restitution and a pocket of low pressure is briefly formed pulling more of the liquid into the pump system. Before looking to standardize the pump systems it must be known how the tension placed by the pumps bearing heads onto the PDMS inserts channels affect the pumps performance (mainly the flow rate produced). The relationship of the speed at which the bearings on the motor head spin and the flow rate must also be established. This research produced calibration curves for flow rate vs. tension and rpm. These calibration curves allow the devices to be set to optimal user settings by simply varying either the motor head tension or the motor head speed. I would like to acknowledge the help and support of Vanderbilt University SyBBURE program, Christina Marasco, Stacy Sherod, Franck Block and Krista McBride.

  10. The Best Bypass Surgery Trial

    DEFF Research Database (Denmark)

    Møller, Christian H; Jensen, Birte Østergaard; Gluud, Christian

    2007-01-01

    Recent trials suggest that off-pump coronary artery bypass grafting (OPCAB) reduces the risk of mortality and morbidity compared with conventional coronary artery bypass grafting (CCAB) using cardiopulmonary bypass. Patients with a moderate- to high-risk of complications after CCAB may have...

  11. Alternative off-site power supply improves nuclear power plant safety

    International Nuclear Information System (INIS)

    Gjorgiev, Blaže; Volkanovski, Andrija; Kančev, Duško; Čepin, Marko

    2014-01-01

    Highlights: • Additional power supply for mitigation of the station blackout event in NPP is used. • A hydro power plant is considered as an off-site alternative power supply. • An upgrade of the probabilistic safety assessment from its traditional use is made. • The obtained results show improvement of nuclear power plant safety. - Abstract: A reliable power system is important for safe operation of the nuclear power plants. The station blackout event is of great importance for nuclear power plant safety. This event is caused by the loss of all alternating current power supply to the safety and non-safety buses of the nuclear power plant. In this study an independent electrical connection between a pumped-storage hydro power plant and a nuclear power plant is assumed as a standpoint for safety and reliability analysis. The pumped-storage hydro power plant is considered as an alternative power supply. The connection with conventional accumulation type of hydro power plant is analysed in addition. The objective of this paper is to investigate the improvement of nuclear power plant safety resulting from the consideration of the alternative power supplies. The safety of the nuclear power plant is analysed through the core damage frequency, a risk measure assess by the probabilistic safety assessment. The presented method upgrades the probabilistic safety assessment from its common traditional use in sense that it considers non-plant sited systems. The obtained results show significant decrease of the core damage frequency, indicating improvement of nuclear safety if hydro power plant is introduced as an alternative off-site power source

  12. Significant reduction in blood loss in patients undergoing minimal extracorporeal circulation

    NARCIS (Netherlands)

    Gerritsen, W. B.; van Boven, W. J.; Smelt, M.; Morshuis, W. J.; van Dongen, H. P.; Haas, F. J.; Aarts, L. P.

    2006-01-01

    Several recent studies have shown differences in blood loss and allogeneic transfusion requirements between on-pump and off-pump coronary artery bypass grafting (CABG). Recently a new concept, the mini-extracorporeal circulation, was introduced to minimize the side effects of extracorporeal

  13. Pump system characterization and reliability enhancement

    International Nuclear Information System (INIS)

    Staunton, R.H.

    1998-01-01

    Pump characterization studies were performed at the Oak Ridge National Laboratory (ORNL) to review and analyze six years (1990-1995) of data from pump systems at domestic nuclear plants. The studies considered not only pumps and pump motors but also pump-related circuit breakers and turbine drives (i.e., the pump system). One significant finding was that the number of 'significant' failures of the pump circuit breaker exceeds the number of significant failures of the pump itself. The study also shows how regulatory code testing was designed for the pump only and therefore did not lead to the discovery of other significant pump system failures. Potential diagnostic technologies, both experimental and mature, suitable for on-line and off-line pump testing were identified. The study does not select or recommend technologies but proposes diagnostic technologies and monitoring techniques that should be further evaluated/developed for making meaningful and critically-needed improvements in the reliability of the pump system. (author)

  14. Comparing cardiovascular factors in opium abusers and non-users candidate for coronary artery bypass graft surgery.

    Science.gov (United States)

    Aghadavoudi, Omid; Eizadi-Mood, Nastaran; Najarzadegan, Mohammad Reza

    2015-01-01

    In some opinions, opium consumption has traditionally been considered to be a means to lower blood lipids and to put off heart diseases. In this study, the relationship between opium consumption and risk factors of coronary artery diseases, hemodynamic factors and cardiac related functions before and after surgery was evaluated. In a cross-sectional study 325 patient's candidate for elective coronary artery bypass grafting were enrolled in a period of 6 months. Opium addicted patients were recognized based on taking history from the patients by an anaesthesiologist. Serum lipid profile was determined at the beginning of the study. Frequency and distribution of coronary artery diseases were assessed according to the pre-operative coronary angiography. From 325 patients, 117 patients were opium abusers and 208 patients were not. Mean duration of opium abuse was 12.6 ± 7.7 years. Mean total serum cholesterol levels were not significantly different in abusers and non-users patients (185 ± 47 vs. 190 ± 49, P > 0.05). Mean level of low-density lipoprotein cholesterol was significantly higher in addicted group (121 ± 27 vs. 81 ± 22, P opium addicted cases. Mean body mass index was also lower in addicted patients significantly (25.3 ± 3.7 vs. 27.5 ± 4.1, P opium abuse and aggravating lipid profile and hypercholesterolemia and coronary artery disease.

  15. High-speed flow visualization in a pump-turbine under off-design operating conditions

    International Nuclear Information System (INIS)

    Hasmatuchi, V; Roth, S; Botero, F; Avellan, F; Farhat, M

    2010-01-01

    The flow hydrodynamics in a low specific speed radial pump-turbine reduced scale model is experimentally investigated under off-design operating conditions in generating mode. Wall pressure measurements, in the stator, synchronized with high-speed flow visualizations in the vaneless space between the impeller and the guide vanes using air bubbles injection are performed. When starting from the best efficiency point and increasing the runner speed, a significant increase of the pressure fluctuations is observed mainly in channels between wicket gates. The spectral analysis shows a rise of one stall cell, rotating with about 70% of the impeller frequency, at runaway, which further increases as the zero discharge condition is approached. Then a specific image processing technique is detailed and applied to create a synthetic instantaneous view of the flow pattern on the entire guide vanes circumference for an operating point in turbine-brake mode, where backflow and vortices accompany the stall passage.

  16. Continuous Perfusion of Saphenous Vein by Oxygenated Blood during Beating Coronary Surgery

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Mandegar

    2015-09-01

    Full Text Available Background: The saphenous vein remains the most commonly used conduit for coronary artery bypass surgery (CABG. However, the long-term success of surgical revascularization is largely limited by development of occlusion in vein grafts. Objectives: We sought to reduce graft ischemia by maintaining the blood flow into the harvested vein throughout surgery at lowest costs and without special devices. Patients and Methods: This study was conducted on three hundred patients aged 58.5 ± 8 years undergoing elective first-time off-pump CABG with saphenous veins. Results: In addition to preserving nutritional materials and oxygen, the veins harvested via this novel technique did not go into spasm and were not subjected to high-pressure distension, eventually resulting in minimal damage to the endothelium. Conclusions: This technique confers favorable myocardial function and protection in the presence of left ventricular dysfunction, especially in elderly patients.

  17. New concepts and new design of permanent maglev rotary artificial heart blood pumps.

    Science.gov (United States)

    Qian, K X; Zeng, P; Ru, W M; Yuan, H Y

    2006-05-01

    According to tradition, permanent maglev cannot achieve stable equilibrium. The authors have developed, to the contrary, two stable permanent maglev impeller blood pumps. The first pump is an axially driven uni-ventricular assist pump, in which the rotor with impeller is radially supported by two passive magnetic bearings, but has one point contact with the stator axially at standstill. As the pump raises its rotating speed, the increasing hydrodynamic force of fluid acting on the impeller will make the rotor taking off from contacting point and disaffiliate from the stator. Then the rotor becomes fully suspended. The second pump is a radially driven bi-ventricular assist pump, i.e., an impeller total artificial heart. Its rotor with two impellers on both ends is supported by two passive magnetic bearings, which counteract the attractive force between rotor magnets and stator coil iron core. The rotor is affiliated to the stator radially at standstill and becomes levitated during rotation. Therefore, the rotor keeps concentric with stator during rotation but eccentric at standstill, as is confirmed by rotor position detection with Honeywell sensors. It concludes that the permanent maglev needs action of a non-magnetic force to achieve stability but a rotating magnetic levitator with high speed and large inertia can maintain its stability merely with passive magnetic bearings.

  18. Off-pump transapical implantation of artificial neo-chordae to correct mitral regurgitation: the TACT Trial (Transapical Artificial Chordae Tendinae) proof of concept.

    Science.gov (United States)

    Seeburger, Joerg; Rinaldi, Mauro; Nielsen, Sten Lyager; Salizzoni, Stefano; Lange, Ruediger; Schoenburg, Markus; Alfieri, Ottavio; Borger, Michael Andrew; Mohr, Friedrich Wilhelm; Aidietis, Audrius

    2014-03-11

    The goal of this study was to evaluate the safety and performance of the NeoChord DS1000 system (NeoChord, Inc., Minneapolis, Minnesota). There is an increasing interest in transcatheter mitral valve (MV) treatment. The NeoChord DS 1000 system enables off-pump beating heart transapical MV repair with implantation of artificial neo-chordae. Patients with severe mitral regurgitation (MR) due to isolated posterior prolapse were included in this TACT (Transapical Artificial Chordae Tendinae) trial. All patients were scheduled for off-pump transapical implantation of neo-chordae. Thirty patients at 7 centers were enrolled. Major adverse events included 1 death due to post-cardiotomy syndrome and concomitant sepsis and 1 minor stroke with the patient fully recovered at the 30-day follow-up visit. Additional patients experienced procedural major adverse events related to a reoperation or conversion to standard of care. Acute procedural success (placement of at least 1 neo-chord and reduction of MR from 3+ or 4+ to ≤2+) was achieved in 26 patients (86.7%). In 4 patients neo-chordae were not placed for technical and/or patient-specific reasons. These patients underwent intraoperative (3 patients) or post-operative (1 patient) standard MV repair. At 30 days, 17 patients maintained an MR grade ≤2+. Four patients who developed recurrent MR were successfully treated with open MV repair during 30-day follow-up. Results improved with experience: durable reduction in MR to ≤2+ at 30 days was achieved in 5 (33.3%) of the first 15 patients and 12 (85.7%) of the last 14 patients. Off-pump transapical implantation of artificial chordae to correct MR is technically safe and feasible; however, it yields further potential for improvement of efficacy and durability. (Safety and Performance Study of the NeoChord Device [TACT]; NCT01777815). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Intraoperative coronary grafts flow measurement using the TTFM flowmeter: results from a domestic sample.

    Science.gov (United States)

    Succi, José Ernesto; Gerola, Luis Roberto; Succi, Guilherme de Menezes; Kim, Hyong Chun; Paredes, Jorge Edwin Morocho; Bufollo, Enio

    2012-01-01

    To evaluate intraoperative graft patency and identify grafts under risk of early occlusion. Fifty four patients were submitted to coronary artery bypass surgery and the graft flow was assessed by the Flowmeter (Medtronic Medistim), which utilizes the TTFM method. Three patients had left main disease and 48 had normal or mildly reduced left ventricular function. In hospital mortality was 3.7% (two patients), one for mesenteric thrombosis and one due to cardiogenic chock. Seventeen patients (34%) were submitted to off pump CABG. Arterial Graft flow measures ranged from 8 to 106 ml/min (average 31.14 ml/min), and venous grafts flow ranged from 9 to 149 ml/min (average 50.42 ml/min). Flowmeter use represents higher safety both for patients and surgeons. Even under legal aspects, the documentation provided by the device can avoid future questionings.

  20. Cell saver for on-pump coronary operations reduces systemic inflammatory markers: a randomized trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Nielsen, Claus Henrik; Andersen, Lars Willy

    2010-01-01

    This study investigated whether intraoperative use of a cell saver reduces the systemic inflammatory response after coronary operations using cardiopulmonary bypass (CPB).......This study investigated whether intraoperative use of a cell saver reduces the systemic inflammatory response after coronary operations using cardiopulmonary bypass (CPB)....

  1. Pulmonary Venous Diastolic Flow Reversal and Flash Pulmonary Edema During Management of Ongoing Myocardial Ischemia with Intraaortic Balloon Pump.

    Science.gov (United States)

    Murray, Davoy; Peng, Yong G

    2015-10-15

    A 65-year-old man was admitted for acute coronary syndrome with depressed left ventricular function and moderate aortic regurgitation. He was managed with an intraaortic balloon pump for circulatory support before coronary artery bypass grafting and subsequently developed flash pulmonary edema with an associated rare finding of diastolic pulmonary venous flow reversal. In this report, we provide a review of intraaortic balloon pump use in current clinical practice and elaborate on the pathophysiology of an uncommon pulmonary venous flow pattern found in our patient.

  2. Mold Heating and Cooling Pump Package Operator Interface Controls Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Josh A. Salmond

    2009-08-07

    The modernization of the Mold Heating and Cooling Pump Package Operator Interface (MHC PP OI) consisted of upgrading the antiquated single board computer with a proprietary operating system to off-the-shelf hardware and off-the-shelf software with customizable software options. The pump package is the machine interface between a central heating and cooling system that pumps heat transfer fluid through an injection or compression mold base on a local plastic molding machine. The operator interface provides the intelligent means of controlling this pumping process. Strict temperature control of a mold allows the production of high quality parts with tight tolerances and low residual stresses. The products fabricated are used on multiple programs.

  3. Bistable direction switching in an off-axis pumped continuous wave ruby laser

    Science.gov (United States)

    Afzal, R. Sohrab; Lawandy, N. M.

    1988-01-01

    A report is presented of the observation of hysteretic bistable direction switching in a single-mode CW ruby laser system. This effect is only observed when the pump beam which is focused into the ruby rod is misaligned with respect to the rod end faces. At low pump powers, the ruby lases in a mode nearly collinear with the pump axis. At a higher pump power the ruby switches to a mode that is collinear with the rod end faces and preserves the original polarization. The effect is large enough to switch the beam by an angle equal to twice the diffraction angle. The observations show that under steady-state pumping, a CW ruby laser can exhibit bistable operation in its output direction and power. A calculation using the heat equation with two concentric cylinders with one as a heat source (pump laser) and the outer wall of the other held at 77 K, gives an increase in core temperature of about 0.01 K. Therefore, the increase in temperature is not large enough to change the index of refraction to account for such large macroscopic effects.

  4. Risk of iron overload is decreased in beating heart coronary artery surgery compared to conventional bypass.

    Science.gov (United States)

    Mumby, S; Koh, T W; Pepper, J R; Gutteridge, J M

    2001-11-29

    Conventional cardiopulmonary bypass surgery (CCPB) increases the iron loading of plasma transferrin often to a state of plasma iron overload, with the presence of low molecular mass iron. Such iron is a potential risk factor for oxidative stress and microbial virulence. Here we assess 'off-pump' coronary artery surgery on the beating heart for changes in plasma iron chemistry. Seventeen patients undergoing cardiac surgery using the 'Octopus' myocardial wall stabilisation device were monitored at five time points for changes in plasma iron chemistry. This group was further divided into those (n=9) who had one- or two- (n=8) vessel grafts, and compared with eight patients undergoing conventional coronary artery surgery. Patients undergoing beating heart surgery had significantly lower levels of total plasma non-haem iron, and a decreased percentage saturation of their transferrin at all time points compared to conventional bypass patients. Plasma iron overload occurred in only one patient undergoing CCPB. Beating heart surgery appears to decrease red blood cell haemolysis, and tissue damage during the operative procedures and thereby significantly decreases the risk of plasma iron overload associated with conventional bypass.

  5. Suggested cut-off values for vitamin D as a risk marker for total and cardiac death in patients with suspected acute coronary syndrome

    Directory of Open Access Journals (Sweden)

    Patrycja Anna Naesgaard

    2016-02-01

    Full Text Available Background: Several studies have demonstrated an association between low vitamin D levels and cardiovascular risk. Vitamin D cut off levels are still under debate. Objectives: To assess two cut-off levels, 40 nmol/L and 70 nmol/L, respectively, for vitamin D measured as 25-hydroxyvitamin D [25(OHD] in chest pain patients with suspected acute coronary syndrome.Methods: We investigated 1853 patients from coastal-Norway and inland Northern-Argentina. A similar database was used for pooling of data. 2-year follow-up data including all-cause mortality, cardiac death and sudden cardiac death in the total patient population were analyzed, applying univariate and multivariable analysis. Results: 255 patients with known vitamin D concentrations died. In the multivariable analysis, there was a decrease in total mortality above a cut-off level of 40 nmol/L and a decrease in cardiac death above a cut-off level of 70 nmol/L, [HRs of 0.66 (95% CI, 0.50 – 0.88, p = 0.004 and 0.46 (95% CI, 0.22 – 0.94, p = 0.034, respectively].Conclusion: Vitamin D cut-off levels of 40 nmol/L and 70 nmol/L, were related to total mortality and cardiac death, respectively.

  6. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    International Nuclear Information System (INIS)

    Zou, Zhichao; Wang, Fujun; Yao, Zhifeng; Tao, Ran; Xiao, Ruofu; Li, Huaicheng

    2016-01-01

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t_0) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t_0, the radial force is small (approaching zero). At 0.4–1.4t_0, the radial force increases rapidly. After 1.4t_0, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research provides a scientific

  7. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhichao [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Wang, Fujun, E-mail: wangfj@cau.edu.cn [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Yao, Zhifeng [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Tao, Ran [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Xiao, Ruofu [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Li, Huaicheng [Shanghai Liancheng (Group) Co., Ltd., Shanghai 201812 (China)

    2016-12-15

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t{sub 0}) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t{sub 0}, the radial force is small (approaching zero). At 0.4–1.4t{sub 0}, the radial force increases rapidly. After 1.4t{sub 0}, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research

  8. Heat Pump Efficiencies simulated in Aspen HYSYS and Aspen Plus

    OpenAIRE

    Øi, Lars Erik; Tirados, Irene Yuste

    2015-01-01

    Heat pump technology provides an efficient and sustainable solution for both heating and cooling. A traditional heat pump can be defined as a mechanical-compression cycle refrigeration system powered by electricity. Traditional refrigerants used in heat pumps are ammonia or chlorinated and fluorinated hydrocarbons. Because many of these chlorofluorohydrocarbons (CFC??) are ozone-depleting components, evaluation of more environmentally friendly refrigerants like pure hydrocarbons is important....

  9. Development of ANC-type empirical two-phase pump model for full size CANDU primary heat transport pump

    International Nuclear Information System (INIS)

    Chan, A.M.C.; Huynh, H.M.

    2004-01-01

    The development of an ANC-type empirical two-phase pump model for CANDU (Canadian Deuterium) reactor primary heat transport pumps is described in the present paper. The model was developed based on Ontario Hydro Technologies' full scale Darlington pump first quadrant test data. The functional form of the ANC model which is widely used was chosen to facilitate the implementation of the model into existing computer codes. The work is part of a bigger test program with the aims: (1) to produce high quality pump performance data under off-normal operating conditions using both full-size and model scale pumps; (2) to advance our basic understanding of the dominant mechanisms affecting pump performance based on more detailed local measurements; and (3) to develop a 'best-estimate' or improved pump model for use in reactor licensing and safety analyses. (author)

  10. Designs for a TFTR full-power pumped limiter

    International Nuclear Information System (INIS)

    Budny, R.

    1986-10-01

    A pumped-limiter system which would provide increased particle control and enhance the performance of full-power discharges is being considered for TFTR. The system consists of two toroidal belts located near the Zirconium-Aluminium (ZrAl) getter panels. The limiter blades would be made of carbon/carbon composite in order to have a very thin profile, allowing a large fraction of the scrape-off flux to be pumped. Simulations of the plasma scrape-off and neutral transport indicate that the limiter pumping should reduce the recycling coefficient by 10 to 25%. Simulations of central plasma processes indicate that the lowered recycling could increase Q/sub fusion/ by more than 100%. This paper discusses the designs and the performance predictions for the system

  11. Particle removal with pump limiters in ISX-B

    International Nuclear Information System (INIS)

    Mioduszewski, P.; Emerson, L.C.; Simpkins, J.E.

    1983-01-01

    First pump limiter experiments were performed on ISX-B. Two pump limiter modules were installed in the top and bottom of one toroidal sector of the tokamak. The modules consist of inertia cooled, TiC coated graphite heads and Zr-Al getter pumps each with a pumping speed of 1000 to 2000 l/s. The objective of the initial experiments was the demonstration of plasma particle control with pump limiters. The first set of experiments were performed in ohmic discharges (OH) in which the effect of the pump limiters on the plasma density was clearly demonstrated. In discharges characterized by: I/sub p/ = 110 kA, B/sub T/ = 15 kG, anti n/sub e/ = 1 - 5 x 10 13 cm -3 and t = 0.3 s the pressure rise in the pump limiters was typically 2 mTorr with the pumps off and 0.7 mTorr after activating the pumps. When the pumps were activated, the line-average plasma density decreased by up to a factor 2 at identical gas flow rates. The second set of measurements were performed in neutral beam heated discharges (NBI) with injected powers between 0.6 MW and 1.0 MW. Due to a cooling problem on one of the Zr-Al pumps the NBI experiments were carried out with one limiter only. The maximum pressure observed in NBI-discharges was 5 mTorr without activating the pumps, i.e., approximately twice as high as in OH-discharges. The exhaust efficiency, which is defined as the removed particle flux over the total particle flux in the scrape-off layer is estimated to be 5%

  12. Pumping of methane by an ionization assisted Zr/Al getter pump

    International Nuclear Information System (INIS)

    Shen, G.L.

    1987-01-01

    The pumping of methane by an ionization assisted Zr/Al getter pump has been investigated. This pump consists of 12 pieces of ring getters. A spiral shape W filament is located within the ring getters. A bias voltage is applied across the filament and the getter itself. The experiments have shown that (1) when the bias voltage is turned off, the pumping speed of the getter pump for methane increases exponentially with the filament temperature; (2) when the filament temperature is held constant, its pumping speed varies directly with the ionization electron current; (3) when the filament temperature is 2063 0 C and the electron current is 57 mA, the pumping speed of the Zr/Al getter pump is 475 ml/s, and the specific speed is 16.8 ml/s cm 2 ; and (4) an activation energy and critical temperature measured for methane molecules decomposition are, respectively, 47.4 kcal/mol and about 1700 0 C. Analysis of the results indicates that methane is pumped by an ionization assisted Zr/Al getter pump not because of the adsorption and the diffusion of methane molecules directly, but because methane molecules are decomposed as C and H 2 through a catalysis of the hot W filament, carbon is adsorbed on the surface of the W filament, and is diffused into the interior of the W lattice. H 2 is immediately absorbed by the Zr/Al getters. Besides, electron impact with CH 4 would result in the additional decomposition and ionization, then the effect of electron bombardment enhances methane pumping by the Zr/Al getters

  13. The association of ABO blood groups with extent of coronary atherosclerosis in Croatian patients suffering from chronic coronary artery disease.

    Science.gov (United States)

    Karabuva, Svjetlana; Carević, Vedran; Radić, Mislav; Fabijanić, Damir

    2013-01-01

    The aim of study was to: 1) examine the relationship between ABO blood groups and extent of coronary atherosclerosis in patients with chronic coronary artery disease (CAD), 2) compare ABO blood groups distribution in CAD patients and general population, 3) examine possible differences in traditional risk factors frequency in CAD patients with different ABO blood groups. In the 646 chronic CAD patients (72.4% males) coronary angiograms were scored by quantitative assessment using multiple angiographic scoring system, Traditional risk factors were self reported or measured by standard methods. ABO blood distribution of patients was compared with group of 651 healthy blood donors (74.6% males). Among all ABO blood group patients there was no significant difference between the extent of coronary atherosclerosis with regard to all the three scoring systems: number of affected coronary arteries (P = 0.857), Gensini score (P = 0.818), and number of segments narrowed > 50% (P = 0.781). There was no significant difference in ABO blood group distribution between CAD patients and healthy blood donors. Among CAD patients, men with blood group AB were significantly younger than their pairs with non-AB blood groups (P = 0.008). Among CAD patients with AB blood group, males groups (P = 0.003). No association between ABO blood groups and the extent of coronary atherosclerosis in Croatian CAD patients is observed. Observation that AB blood group might possibly identify Croatian males at risk to develop the premature CAD has to be tested in larger cohort of patients.

  14. News from heat-pump research - Large-scale heat pumps, components, heat pumps and solar heating; News aus der Waermepumpen-Forschung - Gross-Waermepumpen, Komponenten, Waermepumpe und Solar

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-06-15

    These proceedings summarise the presentations made at the 16{sup th} annual meeting held by the Swiss Federal Office of Energy's Heat Pump Research Program in Burgdorf, Switzerland. The proceedings include contributions on large-scale heat pumps, components and the activities of the heat pump promotion society. A summary of targets and trends in energy research in general is presented and an overview of the heat pump market in 2009 and future perspectives is given. International work within the framework of the International Energy Agency's heat pump group is reviewed, including solar - heat pump combinations. Field-monitoring and the analysis of large-scale heat pumps are discussed and the importance of the use of correct concepts in such installations is stressed. Large-scale heat pumps with carbon dioxide as working fluid are looked at, as are output-regulated air/water heat pumps. Efficient system solutions with heat pumps used both to heat and to cool are discussed. Deep geothermal probes and the potential offered by geothermal probes using carbon dioxide as a working fluid are discussed. The proceedings are rounded off with a list of useful addresses.

  15. Hydrostatic radial bearing of centrifugal pump

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    A hydrostatic radial pump is described characterized by the fact that part of the medium off-taken from delivery is used as a lubricating medium. Two additional bodies are placed alongside a hydrostatic bearing with coils in between them and the pump shaft; the coils have an opposite pitch. The feed channel for the hydrostatic bearing pocket is linked to delivery. The coil outlets are connected to the pump suction unit. Two rotating coils placed alongside the hydrostatic bearing will considerably simplify the communication channel design and reduce the dependence on the pump shaft deflections. The addition of another rotating coil in the close vicinity of the pump shaft or directly on the shaft further increases the efficiency. The bearing can be used in designing vertical circulating pumps for the cooling circuits of nuclear reactors. (J.B.)

  16. Quantitative coronary CT angiography: absolute lumen sizing rather than %stenosis predicts hemodynamically relevant stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Plank, Fabian [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria); Innsbruck Medical University, Department of Internal Medicine III - Cardiology, Innsbruck (Austria); Burghard, Philipp; Mayr, Agnes; Klauser, Andrea; Feuchtner, Gudrun [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria); Friedrich, Guy; Dichtl, Wolfgang [Innsbruck Medical University, Department of Internal Medicine III - Cardiology, Innsbruck (Austria); Wolf, Florian [Vienna Medical University, Department of Cardiovascular and Interventional Radiology, Vienna (Austria)

    2016-11-15

    To identify the most accurate quantitative coronary stenosis parameter by CTA for prediction of functional significant coronary stenosis resulting in coronary revascularization. 160 consecutive patients were prospectively examined with CTA. Proximal coronary stenosis was quantified by minimal lumen area (MLA) and minimal lumen diameter (MLD), %area and %diameter stenosis. Lesion length (LL) was measured. The reference standard was invasive coronary angiography (ICA) (>70 % stenosis, FFR <0.8). 210 coronary segments were included (59 % positive). MLA of ≤1.8 mm{sup 2} was identified as the optimal cut-off (c = 0.97, p < 0.001; 95 % CI 0.94-0.99) (sensitivity 90.9 %, specificity 89.3 %) for prediction of functional-relevant stenosis (for MLA >2.1 mm{sup 2} sensitivity was 100 %). The optimal cut-off for MLD was 1.2 mm (c = 0.92; p < 0.001; 95 % CI 0.88-95) (sensitivity 90.9, specificity 85.2) while %area and %diameter stenosis were less accurate (c = 0.89; 95 % CI 0.84-93, c = 0.87; 95 % CI 0.82-92, respectively, with thresholds at 73 % and 61 % stenosis). Accuracy for LL was c = 0.74 (95 % CI 0.67-81), and for LL/MLA and LL/MLD ratio c = 0.90 and c = 0.84. MLA ≤1.8 mm{sup 2} and MLD ≤1.2 mm are the most accurate cut-offs for prediction of haemodynamically significant stenosis by ICA, with a higher accuracy than relative % stenosis. (orig.)

  17. Acute Coronary Syndromes: From The Laboratory Markers To The Coronary Vessels

    Directory of Open Access Journals (Sweden)

    Palazzuoli Alberto

    2006-01-01

    Full Text Available A number of "interesting" risk markers have been proposed as providing prognostic information in acute coronary syndromes (ACS. Elevation in plasma inflammatory and necrosis biomarkers have been related to future cardiovascular events in individuals with or without prior myocardial infarction. Recently BNP and pro-BNP are entered in clinical practice to recognize patients at major risk, providing incremental information respect to the traditional markers. Together with these laboratory indexes, a few of promising laboratory markers once easily available, could become useful in identification of patients at high risk. Several studies evaluated many markers of platelet aggregation, endothelial dysfunction and vascular thrombosis, but it is not yet clear whether each of the proposed markers may provide incremental predictive information. We describe, following the most studies reported in literature, the laboratory markers with potential clinical and prognostic power that could early help physicians in the identifi cation of patients with impaired coronary disease and more narrowed coronary arteries.

  18. Pump failure leads to alternative vertical pump condition monitoring technique

    International Nuclear Information System (INIS)

    DeVilliers, Adriaan; Glandon, Kevin

    2011-01-01

    Condition monitoring and detecting early signs of potential failure mechanisms present particular problems in vertical pumps. Most often, the majority of the pump assembly is not readily accessible for visual or audible inspection or conventional vibration monitoring techniques using accelerometers and/or proximity sensors. The root cause failure analysis of a 2-stage vertical centrifugal service-water pump at a nuclear power generating facility in the USA is presented, highlighting this long standing challenge in condition monitoring of vertical pumps. This paper will summarize the major findings of the root cause analysis (RCA), highlight the limitations of traditional monitoring techniques, and present an expanded application of motor current monitoring as a means to gain insight into the mechanical performance and condition of a pump. The 'real-world' example of failure, monitoring and correlation of the monitoring technique to a detailed pump disassembly inspection is also presented. This paper will explain some of the reasons behind well known design principles requiring natural frequency separation from known forcing frequencies, as well as explore an unexpected submerged brittle fracture failure mechanism, and how such issues may be avoided. (author)

  19. Ranking of psychosocial and traditional risk factors by importance for coronary heart disease

    DEFF Research Database (Denmark)

    Schnohr, Peter; Marott, Jacob L; Kristensen, Tage S.

    2015-01-01

    .001] and systolic blood pressure (≥160 mmHg or blood pressure medication vs. never smoker; HR 1.74; 95% CI, 1.43-2.11; P ...-statistics and net reclassification improvement. During the follow-up, 1731 non-fatal and fatal coronary events were registered. In men, the highest ranking risk factors for coronary heart disease were vital exhaustion [high vs. low; hazard ratio (HR) 2.36; 95% confidence interval (CI), 1.70-3.26; P

  20. Relationship between pre-extubation positive endexpiratory pressure and oxygenation after coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Reijane Oliveira Lima

    2015-08-01

    Full Text Available Abstract Introduction After removal of endotracheal tube and artificial ventilation, ventilatory support should be continued, offering oxygen supply to ensure an arterial oxygen saturation close to physiological. Objective: The aim of this study was to investigate the effects of positive-end expiratory pressure before extubation on the oxygenation indices of patients undergoing coronary artery bypass grafting. Methods: A randomized clinical trial with seventy-eight patients undergoing coronary artery bypass grafting divided into three groups and ventilated with different positive-end expiratory pressure levels prior to extubation: Group A, 5 cmH2O (n=32; Group B, 8 cmH2O (n=26; and Group C, 10 cmH2O (n=20. Oxygenation index data were obtained from arterial blood gas samples collected at 1, 3, and 6 h after extubation. Patients with chronic pulmonary disease and those who underwent off-pump, emergency, or combined surgeries were excluded. For statistical analysis, we used Shapiro-Wilk, G, Kruskal-Wallis, and analysis of variance tests and set the level of significance at P<0.05. Results Groups were homogenous with regard to demographic, clinical, and surgical variables. There were no statistically significant differences between groups in the first 6 h after extubation with regard to oxygenation indices and oxygen therapy utilization. Conclusion: In this sample of patients undergoing coronary artery bypass grafting, the use of different positive-end expiratory pressure levels before extubation did not affect gas exchange or oxygen therapy utilization in the first 6 h after endotracheal tube removal.

  1. Intermittency and Inflexibility Blister Pump Impress Factors

    OpenAIRE

    Mlakar, Boštjan; Zupančič, Cvetko

    2011-01-01

    Divisional centralized heating and cooling system, cogeneratton system of heat and power and power-gas cogeneration system. In order to further fully and reasonably use the heat in doubleeffect absorption units, double-stage bubble pump must be involved in the adoption o u pump replacing the traditional mechanical solution pump. It was designed a secon generator based on a solar pump-free lithium bromide absorption chiller system. The expenmen adopts the lunate thermosiphon elevation tube, ef...

  2. The role of capacitance in a wind-electric water pumping system

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Shitao [West Texas A& M Univ., Canyon, TX (United States); Clark, R.N. [Conservation and Production Research Lab., Bushland, TX (United States)

    1997-12-31

    The development of controllers for wind-electric water pumping systems to enable the use of variable voltage, variable frequency electricity to operate standard AC submersible pump motors has provided a more efficient and flexible water pumping system to replace mechanical windmills. A fixed capacitance added in parallel with the induction motor improves the power factor and starting ability of the pump motor at the lower cut-in frequency. The wind-electric water pumping system developed by USDA-Agricultural Research Service, Bushland, TX, operated well at moderate wind speeds (5-12 m/s), but tended to lose synchronization in winds above 12 m/s, especially if they were gusty. Furling generally did not occur until synchronization had been lost and the winds had to subside before synchronization could be reestablished. The frequency needed to reestablish synchronization was much lower (60-65 Hz) than the frequency where synchronization was lost (70-80 Hz). As a result, the load (motor and pump) stayed off an excessive amount of time thus causing less water to be pumped and producing a low system efficiency. The controller described in this paper dynamically connects additional capacitance of the proper amount at the appropriate time to keep the system synchronized (running at 55 to 60 Hz) and pumping water even when the wind speed exceeds 15 m/s. The system efficiency was improved by reducing the system off-line time and an additional benefit was reducing the noise caused by the high speed blade rotation when the load was off line in high winds.

  3. Coupled plasma-neutral transport model for the scrape-off region

    International Nuclear Information System (INIS)

    Galambos, J.D.; Peng, Y.K.M.; Heifetz, D.

    1985-03-01

    Analysis of the scrape-off region requires treatment of the plasma transport along and across the field lines and inclusion of the neutral transport effects. A method for modeling the scrape-off region that is presented here uses separate models for each of these aspects that are coupled together through an iteration procedure that requires only minimal numerical effort. The method is applied here to estimate the neutral pumping rates in the pump-limiter and divertor options for a proposed deuterium-tritium (D-T) ignition experiment. High neutral recycling in the vicinity of the neutralizer plate dramatically affects pumping rates for both the pump-limiter and divertor. In both cases, the plasma flow into the channel surrounding the neutralizer plate is greatly reduced by the neutral recycling. The fraction of this flow that is pumped can be large (> 50%), but in general it is dependent on the particular geometry and plasma conditions. It is estimated that pumping speeds approximately greater than 10 5 L/s are adequate for the exhaust requirements in the pump-limiter and the divertor cases. Also, high neutral recycling on the front surface of the limiter tends to increase the neutral pumping rate

  4. Noninvasive FFR derived from coronary CT angiography in the management of coronary artery disease: technology and clinical update

    Directory of Open Access Journals (Sweden)

    Nakanishi R

    2016-06-01

    Full Text Available Rine Nakanishi, Mathew J Budoff Los Angeles Biomedical Research Institute, Harbor-UCLA Medical Center, Torrance, CA, USA Abstract: After a decade of clinical use of coronary computed tomographic angiography (CCTA to evaluate the anatomic severity of coronary artery disease, new methods of deriving functional information from CCTA have been developed. These methods utilize the anatomic information provided by CCTA in conjunction with computational fluid dynamics to calculate fractional flow reserve (FFR values from CCTA image data sets. Computed tomography-derived FFR (CT-FFR enables the identification of lesion-specific drop noninvasively. A three-dimensional CT-FFR modeling technique, which provides FFR values throughout the coronary tree (HeartFlow FFRCT analysis, has been validated against measured FFR and is now approved by the US Food and Drug Administration for clinical use. This technique requires off-site supercomputer analysis. More recently, a one-dimensional computational analysis technique (Siemens cFFR, which can be performed on on-site workstations, has been developed and is currently under investigation. This article reviews CT-FFR technology and clinical evidence for its use in stable patients with suspected coronary artery disease. Keywords: fractional flow reserve, coronary computed tomographic angiography, FFRCT, cFFR

  5. Cryogenic storage tank with built-in pump

    International Nuclear Information System (INIS)

    Zwick, E.B.

    1984-01-01

    A cryogenic storage tank with a built-in pump for pumping cryogen directly from the primary storage container consistent with low boil-off losses of cryogen has an outer vessel, an inner vessel and an evacuated insulation space therebetween. A pump mounting tube assembly extends into the interior of the inner vessel and includes an inner pump mounting tube and an outer pump mounting tube joined at their lower rims to define an insulating jacket between the two tubes. The inner pump mounting tube is affixed at its upper end to the outer vessel while the outer pump mounting tube is affixed at its upper end to the inner vessel. The inner pump mounting tube defines a relatively long heat path into the cryogenic container and is itself insulated from the liquid cryogen by a pocket of trapped gas formed within the inner pump mounting tube by heated cryogen. A pump may be introduced through the inner pump mounting tube and is also insulated against contact with liquid cryogen by the trapped gas such that only the lowermost end of the pump is immersed in cryogen thereby minimizing heat leakage into the tank

  6. The coronary arteries of the agouti (Agouti paca, Linnaeus, 1766

    Directory of Open Access Journals (Sweden)

    Fabrício Singaretti de Oliveira

    2009-12-01

    Full Text Available The present study aimed to describe the coronary arteries in the agouti. Twelve hearts set, in a 10% formaldehyde aqueous solution, were used. The presence of left and right coronary arteries was observed in all hearts. The fi rst arose from the aorta, between the left auricle and the pulmonary trunk, and gave off into a circumfl ex branch, whichever was directed to the right surface of this viscerae, and an interventricular paraconal branch that went through the cardiac apex, on the left atrioventricular sulcus. In 91.6% of the cases, at its origin, the paraconal branch gave off a thick side branch to the left ventricle wall, and in 100% of the cases, went deep, characterizing a large myocardial bridge. In 8.4% of the cases, this thick side branch to the left ventricle wall originated directly from the left coronary artery and not from the paraconal branch, and alterations such those to the circumfl ex branch did not occur. Regarding the right coronary artery, the origin of this vessel was from the aorta, on the atrial surface, in the direction of the right ventricular border, going through the subsinuous interventricular sulcus as an interventricular subsinuous branch.

  7. Concomitant use of proton pump inhibitors and clopidogrel in patients with coronary, cerebrovascular, or peripheral artery disease in the factores de Riesgo y ENfermedad Arterial (FRENA) registry.

    Science.gov (United States)

    Muñoz-Torrero, Juan Francisco Sánchez; Escudero, Domingo; Suárez, Carmen; Sanclemente, Carmen; Pascual, Ma Teresa; Zamorano, José; Trujillo-Santos, Javier; Monreal, Manuel

    2011-01-01

    Among patients receiving clopidogrel for coronary artery disease, concomitant therapy with proton pump inhibitors (PPIs) has been associated with an increased risk for recurrent coronary events. Factores de Riesgo y ENfermedad Arterial (FRENA) is an ongoing, multicenter, observational registry of consecutive outpatients with coronary artery disease, cerebrovascular disease, or peripheral artery disease. We retrospectively examined the influence of concomitant use of PPIs on outcome in patients receiving clopidogrel. As of March 2009, 1222 patients were using clopidogrel: 595 had coronary artery disease, 329 cerebrovascular disease, and 298 had peripheral artery disease. Of these, 519 (42%) were concomitantly using PPIs. Over a mean follow-up of 15 months, 131 patients (11%) had 139 subsequent ischemic events: myocardial infarction 44, ischemic stroke 40, and critical limb ischemia 55. Seventeen of them (13%) died within 15 days of the subsequent event. PPI users had a higher incidence of myocardial infarction (rate ratio, 2.5; 95% confidence interval [CI], 1.3-4.8), ischemic stroke (rate ratio, 1.9; 95% CI, 1.03-3.7), and a nonsignificantly higher rate of critical limb ischemia (rate ratio, 1.6; 95% CI, 0.95-2.8) than nonusers. On multivariate analysis, concomitant use of clopidogrel and PPIs was independently associated with an increased risk for subsequent ischemic events both in the whole series of patients (hazard ratio, 1.8; 95% CI, 1.1-2.7) and in those with cerebrovascular disease or peripheral artery disease (hazard ratio, 1.5; 95% CI, 1.01-2.4). In patients with established arterial disease, concomitant use of PPIs and clopidogrel was associated with a nearly doubling of the incidence of subsequent myocardial infarction or ischemic stroke. This higher incidence persisted after multivariate adjustment.

  8. LD pumped Nd: YLF amplification technology

    International Nuclear Information System (INIS)

    Qin Xingwu; Li Mingzhong; Luo Yiming; Sui Zhan; Ding Lei; Liang Yue; Zhao Runchang; Chen Lianming

    2003-01-01

    A Ring-LD-pumped Nd: YLF laser amplifier system is theoretically and experimentally discussed. A structure of off-axes double passes amplifier is used. The results of experiment shown that 109 mJ output energy with a net gain of 1115 is obtained under 150 μJ input energy; a compact side-pumped structure is used to obtain a high transferring efficiency of LD array, 1.01 J output energy is achieved at 1053 nm. (authors)

  9. Anomalous Origin of the Right Coronary Artery from the Left Anterior Descending Coronary Artery in a Patient with Ascending Aortic Aneurysm

    Directory of Open Access Journals (Sweden)

    Ufuk Gürkan

    2012-04-01

    Full Text Available The incidence of coronary artery anomalies has been reported between 0.6 to 1.3% in angiographic series and 0.3% in autopsy series. An isolated single coronary artery (SCA is even a rarer congenital anomaly occurring in approximately 0.02% of the population. The ectopic origin of the right coronary artery (RCA from the left anterior descending (LAD artery is relatively rare and more benign than other types of anomalous origin of the RCAs. We report a case of an adult male patient with SCA anomaly in which the RCA takes off from the mid LAD. To the best of our knowledge, SCA anomaly coinciding with ascending aortic aneurysm which was treated with Bentall operation has never been described before.

  10. Parametric studies and optimisation of pumped thermal electricity storage

    International Nuclear Information System (INIS)

    McTigue, Joshua D.; White, Alexander J.; Markides, Christos N.

    2015-01-01

    Highlights: • PTES is modelled by cycle analysis and a Schumann-style model of the thermal stores. • Optimised trade-off surfaces show a flat efficiency vs. energy density profile. • Overall roundtrip efficiencies of around 70% are not inconceivable. - Abstract: Several of the emerging technologies for electricity storage are based on some form of thermal energy storage (TES). Examples include liquid air energy storage, pumped heat energy storage and, at least in part, advanced adiabatic compressed air energy storage. Compared to other large-scale storage methods, TES benefits from relatively high energy densities, which should translate into a low cost per MW h of storage capacity and a small installation footprint. TES is also free from the geographic constraints that apply to hydro storage schemes. TES concepts for electricity storage rely on either a heat pump or refrigeration cycle during the charging phase to create a hot or a cold storage space (the thermal stores), or in some cases both. During discharge, the thermal stores are depleted by reversing the cycle such that it acts as a heat engine. The present paper is concerned with a form of TES that has both hot and cold packed-bed thermal stores, and for which the heat pump and heat engine are based on a reciprocating Joule cycle, with argon as the working fluid. A thermodynamic analysis is presented based on traditional cycle calculations coupled with a Schumann-style model of the packed beds. Particular attention is paid to the various loss-generating mechanisms and their effect on roundtrip efficiency and storage density. A parametric study is first presented that examines the sensitivity of results to assumed values of the various loss factors and demonstrates the rather complex influence of the numerous design variables. Results of an optimisation study are then given in the form of trade-off surfaces for roundtrip efficiency, energy density and power density. The optimised designs show a

  11. Coronary artery bypass grafting-related bleeding complications in patients treated with dual antiplatelet treatment

    NARCIS (Netherlands)

    Tomšič, Anton; Schotborgh, Mark A.; Manshanden, Johan S. J.; Li, Wilson W. L.; de Mol, Bas A. J. M.

    2016-01-01

    To evaluate the relationship between the timing of either ticagrelor or clopidogrel discontinuation and bleeding-related complications in patients undergoing isolated on-pump coronary artery bypass grafting (CABG). Between January 2012 and December 2014, 705 consecutive patients underwent isolated

  12. Coronary artery bypass grafting-related bleeding complications in patients treated with dual antiplatelet treatment.

    NARCIS (Netherlands)

    Tomsic, A.; Schotborgh, M.A.; Manshanden, J.S.; Li, W.W.L.; Mol, B.A. de

    2016-01-01

    OBJECTIVES: To evaluate the relationship between the timing of either ticagrelor or clopidogrel discontinuation and bleeding-related complications in patients undergoing isolated on-pump coronary artery bypass grafting (CABG). METHODS: Between January 2012 and December 2014, 705 consecutive patients

  13. [Percutaneous approach for the treatment of unprotected left main coronary stenosis. New perspectives with the use of coronary stents].

    Science.gov (United States)

    Pessanha, A V; Rodrigues, C; Fuks, V; Murad, H; Murad, M

    1997-03-01

    We describe a case of coronary stenosis located in an unprotected left main coronary artery, treated primarily and electively with the placement of a coronary stent. As a function of the large mass of myocardium involved, this patient would be considered a classical candidate for direct surgery, because the inherent risk involved with conventional balloon angioplasty, mainly due to the eventual occurrence of acute closure during the procedure. Since the previsibility of the immediate results with the use of coronary stents was significantly improved, we propose this new therapeutic approach for this traditionally surgical case, that has been performed with success and without any complication. This strategy for the treatment of unprotected left main lesions with the elective placement of Palmaz-Schatz stents, has not yet been proposed or applied in our country, and may represent a new universe of indication of percutaneous treatment of coronary artery disease, no longer approaching the left main stem only in special or emergency situations, usually a result of complications of left main manipulation during angioplasty of the coronary system. The patient involved in this case did not show any contraindication for the treatment with conventional open heart surgery.

  14. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.

    1984-05-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6MW of auxiliary neutral beam heating. Experiments have also been done with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a region may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this Z-mode of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described

  15. Tokamak pump limiters

    International Nuclear Information System (INIS)

    Conn, R.W.; California Univ., Los Angeles

    1984-01-01

    Recent experiments with a scoop limiter without active internal pumping have been carried out in the PDX tokamak with up to 6 MW of auxiliary neutral beam heating. Experiments have also been performed with a rotating head pump limiter in the PLT tokamak in conjunction with RF plasma heating. Extensive experiments have been done in the ISX-B tokamak and first experiments have been completed with the ALT-I limiter in TEXTOR. The pump limiter modules in these latter two machines have internal getter pumping. Experiments in ISX-B are with ohmic and auxiliary neutral beam heating. The results in ISX-B and TEXTOR show that active density control and particle removal is achieved with pump limiters. In ISX-B, the boundary layer (or scrape-off layer) plasma partially screens the core plasma from gas injection. In both ISX-B and TEXTOR, the pressure internal to the module scales linearly with plasma density but in ISX-B, with neutral beam injection, a nonlinear increase is observed at the highest densities studied. Plasma plugging is the suspected cause. Results from PDX suggest that a regime may exist in which core plasma energy confinement improves using a pump limiter during neutral beam injection. Asymmetric radial profiles and an increased edge electron temperature are observed in discharges with improved confinement. The injection of small amounts of neon into ISX-B has more clearly shown an improved electron core energy confinement during neutral beam injection. While carried out with a regular limiter, this 'Z-mode' of operation is ideal for use with pump limiters and should be a way to achieve energy confinement times similar to values for H-mode tokamak plasmas. The implication of all these results for the design of a reactor pump limiter is described. (orig.)

  16. Pre-operative high sensitive C-reactive protein predicts cardiovascular events after coronary artery bypass grafting surgery: A prospective observational study

    Directory of Open Access Journals (Sweden)

    Balciunas Mindaugas

    2009-01-01

    Full Text Available C-reactive protein is a powerful independent predictor of cardiovascular events in patients with coronary artery disease. The relation between C-reactive protein (CRP concentration and in-hospital outcome, after coronary artery bypass grafting (CABG, has not yet been established. The study aims to evaluate the predictive value of pre-operative CRP for in-hospital cardiovascular events after CABG surgery. High-sensitivity CRP (hs-CRP levels were measured pre-operatively on the day of surgery in 66 patients scheduled for elective on pump CABG surgery. Post-operative cardiovascular events such as death from cardiovascular causes, ischemic stroke, myocardial damage, myocardial infarction and low output heart failure were recorded. During the first 30 days after surgery, 54 patients were free from observed events and 14 developed the following cardiovascular events: 10 (15% had myocardial damage, four (6% had low output heart failure and two (3% suffered stroke. No patients died during the follow-up period. Serum concentration of hs-CRP ≥ 3.3 mg/l (cut-off point obtained by ROC analysis was related to higher risk of post-operative cardiovascular events (36% vs 6%, P = 0.01, myocardial damage (24% vs 6%, P = 0.04 and low output heart failure (12% vs 0%, P = 0.04. Multivariate logistic regression analysis showed that hs-CRP ≥ 3.3 mg/l ( P = 0.002, O.R.: 19.3 (95% confidence interval (CI 2.9-128.0, intra-operative transfusion of red blood cells ( P = 0.04, O.R.: 9.9 (95% C.I. 1.1-85.5 and absence of diuretics in daily antihypertensive treatment ( P = 0.02, O.R.: 15.1 (95% C.I. 1.4-160.6 were independent predictors of combined cardiovascular event. Patients having hs-CRP value greater or equal to 3.3 mg/l pre-operatively have an increased risk of post-operative cardiovascular events after on pump coronary artery bypass grafting surgery.

  17. Analytical studies on pump-induced optical resonances in an M-type six-level system

    International Nuclear Information System (INIS)

    Ghosh, Saswata; Mandal, Swapan

    2010-01-01

    In the domain of semiclassical formulation and for the Doppler-free atom-field interaction, we construct the optical Bloch equations involving an M-type six-level system coupled to two pump fields and a probe field. The response of the system is probed for different pump-induced transitions in double and triple-resonance situations. In order to obtain the coherent lineshapes (absorptive and dispersive), we use the usual perturbation method for obtaining the approximate analytical solutions to these coupled optical Bloch equations for the density matrix elements. The interferences between the probability amplitudes for different energy levels (dipole allowed and dipole forbidden) are taken care of. For off-resonance pump positions, the linewidths of the three probe transitions are insensitive to the pump Rabi frequencies. On the other hand, the shifts of the three resonance peaks are extremely sensitive to the pump Rabi frequencies. However, for on-resonance pump conditions, the sensitivities of pump Rabi frequencies on the linewidths of the resonance peaks and on the shifts of the resonance peak positions are opposite to those of their off-resonance counterparts. In particular, we have shown the asymmetric and symmetric Rabi splittings under different physical conditions, for non-zero and near-zero probe detuning, respectively. The Rabi splitting under triple-resonance conditions, significantly, modifies the dispersive lineshape at the centre of the absorption line. The two- and three-photon absorptions are also reported for different off-resonant pump positions.

  18. Acute Right Coronary Ostial Stenosis during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Sarwar Umran

    2012-01-01

    Full Text Available We report a rare case of acute right coronary artery stenosis developing in a patient undergoing aortic valve replacement. We present a case report with a brief overview of the literature relating to coronary artery occlusion associated with cardiac valve surgery - the theories and treatments are discussed. A 85 year-old female was admitted under the care of the cardiothoracic team with signs and symptoms of heart failure. Investigations, including cardiac echocardiography and coronary angiography, indicated a critical aortic valve stenosis. Intraoperative right ventricular failure ensued post aortic valve replacement. Subsequent investigations revealed an acute occlusion of the proximal right coronary artery with resultant absence of distal flow supplying the right ventricle. An immediate right coronary artery bypass procedure was performed with resolution of the right ventricular failure. Subsequent weaning off cardiopulmonary bypass was uneventful and the patient continued to make excellent recovery in the postoperative phase. To our knowledge this is one of the few documented cases of intraoperative acute coronary artery occlusion developing during valve surgery. However, surgeons should be aware of the potential for acute occlusion so that early recognition and rapid intervention can be instituted.

  19. Virtual 5-French intra-aortic pumping using a Glidesheath Slender and 6-French intra-aortic balloon catheter

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: a-takahashi@wine.ocn.ne.jp; Taniguchi, Norimasa; Mizuguchi, Yukio; Yamada, Takeshi; Nakajima, Shunsuke; Hashimoto, Sho; Hata, Tetsuya

    2015-07-15

    Objectives: The aim of this study was to evaluate the feasibility and safety of the 6-Fr Glidesheath Slender, which has equivalent outer size to the conventional 5-Fr sheath, for use with the 6-Fr intra-aortic balloon pump (IABP) catheter. Methods: Between May 2014 and March 2015, 24 patients with acute coronary syndrome underwent percutaneous coronary intervention using a 6-Fr IABP catheter through a 6-Fr Glidesheath Slender for support. The adverse events, including access site complications, kinking of the sheath during the procedure, and any evidence of balloon pump failure, were retrospectively investigated. Results: Insertion of the IABP catheter through either the femoral or brachial artery was successful in all patients. The mean support time was 32.4 ± 22.0 h. No major hemorrhagic event or severe limb ischemia was observed. Kinking of the shaft occurred during insertion in one patient; however, the subsequent balloon pumping was well maintained and did not require exchange of the sheath or IABP catheter. No kind of IABP failure was observed. Conclusion: Although this sheath was originally designed to allow radial access, our results suggest that the use of the Glidesheath Slender is feasible for insertion of the 6-Fr IABP catheter through the brachial and femoral arteries, and may reduce vascular complications in patients who undergo percutaneous coronary intervention.

  20. Revascularização do miocárdio sem circulação extracorpórea em idosos: análise da morbidade e mortalidade Off-pump myocardial revascularization in the elderly: analysis of morbidity and mortality

    Directory of Open Access Journals (Sweden)

    Ana Maria Rocha Pinto e Silva

    2008-03-01

    Full Text Available OBJETIVO: Analisar a evolução intra-hospitalar de doentes com 70 anos de idade ou mais, submetidos a revascularização do miocárdio sem circulação extracorpórea, com uso de shunt intracoronário, operados na urgência, emergência e eletivamente. MÉTODOS: Foram submetidos à cirurgia 87 doentes com idade entre 70 e 92 anos de julho de 1989 a julho de 2005. Dos 87 doentes, 50 (57,5% eram portadores de angina instável, sendo três (3,4% na vigência de infarto agudo do miocárdio. Foram operados em caráter de emergência e urgência 31 (35,6% doentes. De todo o grupo, havia 13 (14,9% doentes com infarto ocorrido em até 30 dias e 34 (39,1% com infarto ocorrido há mais de 30 dias. RESULTADOS: As complicações mais freqüentes foram: fibrilação atrial (32,2%, insuficiência cardíaca congestiva (12,6%, broncopneumonia (10,3%, sepse (3,4%, infarto agudo do miocárdio peri-operatório (2,3%, mediastinite (1,1%, acidente isquêmico transitório (1,1%, pneumotórax (1,1%. O tempo médio de intubação foi de 18,50±19,09 horas; permanência em UTI, 2,92±2,03 dias, e hospitalar, 10,55±7,16 dias. Apenas nove (10,3% doentes receberam concentrado de hemácias no pós-operatório e nenhum foi reoperado por sangramento. A mortalidade hospitalar foi de 4,6%. CONCLUSÃO: Em doentes acima de 70 anos, operados na emergência, urgência e eletivamente, a revascularização do miocárdio sem extracorpórea com shunt intracoronário apresentou adequada evolução pós-operatória e baixos índices de complicações e mortalidade em relação à população estudada.OBJECTIVE: To analyze the in-hospital outcome of elderly patients aged 70 years and older who underwent off-pump coronary artery bypass graft surgery with an intraluminal shunt in urgent, emergent, and elective coronary revascularizations. METHODS: From July 1989 to July 2005, we analyzed 87 patients ranging in age from 70 to 92 years. Of the 87 patients enrolled, 50 (57.5% patients had

  1. Analysis of the pump-turbine S characteristics using the detached eddy simulation method

    Science.gov (United States)

    Sun, Hui; Xiao, Ruofu; Wang, Fujun; Xiao, Yexiang; Liu, Weichao

    2015-01-01

    Current research on pump-turbine units is focused on the unstable operation at off-design conditions, with the characteristic curves in generating mode being S-shaped. Unlike in the traditional water turbines, pump-turbine operation along the S-shaped curve can lead to difficulties during load rejection with unusual increases in the water pressure, which leads to machine vibrations. This paper describes both model tests and numerical simulations. A reduced scale model of a low specific speed pump-turbine was used for the performance tests, with comparisons to computational fluid dynamics(CFD) results. Predictions using the detached eddy simulation(DES) turbulence model, which is a combined Reynolds averaged Naviers-Stokes(RANS) and large eddy simulation(LES) model, are compared with the two-equation turbulence mode results. The external characteristics as well as the internal flow are for various guide vane openings to understand the unsteady flow along the so called S characteristics of a pump-turbine. Comparison of the experimental data with the CFD results for various conditions and times shows that DES model gives better agreement with experimental data than the two-equation turbulence model. For low flow conditions, the centrifugal forces and the large incident angle create large vortices between the guide vanes and the runner inlet in the runner passage, which is the main factor leading to the S-shaped characteristics. The turbulence model used here gives more accurate simulations of the internal flow characteristics of the pump-turbine and a more detailed force analysis which shows the mechanisms controlling of the S characteristics.

  2. Nasal deposition and clearance in man: comparison of a bidirectional powder device and a traditional liquid spray pump.

    Science.gov (United States)

    Djupesland, Per Gisle; Skretting, Arne

    2012-10-01

    Delivery of powder formulations to the nose is an attractive alternative for many drugs and vaccines. This study compared the regional nasal deposition and clearance patterns of lactose powder delivered by the OptiNose powder device (Opt-Powder; OptiNose US Inc., Yardley, PA, USA) to that of liquid aerosol administered via a traditional hand-actuated liquid spray pump (Rexam SP270, Rexam Pharma, France). The study was an open-label, crossover design in seven healthy subjects (five females, two males). The regional nasal deposition and clearance patterns of the Opt-Powder device were compared to a traditional liquid spray pump by dynamic gamma camera imaging after administration of either (99m)Tc-labeled lactose powder or liquid (99m)Tc- diethelyne triamine pentaacetic acid-aerosol. The gamma camera images were scaled and aligned with sagittal magnetic resonance images to identify nasal regions. Possible deposition of radiolabeled material in the lungs following both methods of delivery was also evaluated. Both powder and spray were distributed to all of the nasal regions. The Opt-Powder device, however, achieved significantly larger initial deposition in the upper and middle posterior regions of the nose than spray (upper posterior region; Opt-Powder 18.3% ± 11.5 vs. Spray 2.4% ± 1.8, pSpray 15.7% ± 13.8, pdeposition to the lower anterior and posterior regions for spray was three times higher compared to Opt-Powder (Opt-Powder 17.4% ± 24.5 vs. Spray 59.4% ± 18.2, pdeposition was observed. The initial deposition following powder delivery was significantly larger in the ciliated mucosa of the upper and posterior nasal regions, whereas less was deposited in the lower regions. Overall nasal clearance of powder was slower initially, but due to retention in anterior nonciliated regions the overall nasal clearance after spray was slower.

  3. Field experience of a project with the Dutch Consultancy Services Wind Energy Developing Countries (CWD) and traditional wind pumps in Nicaragua

    International Nuclear Information System (INIS)

    Holtslag, H.A.G.

    1991-01-01

    The main objective of the title project, which started in October 1986, was to promote the use of wind energy in Nicaragua by means of a study on the wind potential, the production and use of wind pumps, and repairs of traditional wind pumps. Involved in the project were a Dutch project coordinator, a Dutch, a German and a Danish advisor for the technical aspects and a Dutch advisor for irrigation. The Nicaraguan National Institute of Energy coordinated the project until 1988. Then the (state) factory, where the mills were manufactured, took over. The study on the wind potential was only partly completed. The production was done at the state factory in Managua (IMEP), where two models were produced: a traditional mill with a rotor of 3 meter, and a CWD-mill with a rotor of 5 meter. Adaptations, based on field experiences, were made in the CWD-model in the third year of the project. The total production after 4 years was 50 mills of 3 meter and 15 mills of 5 meter. The objective was 200 mills per year after the third year of the project. Of the 3 meter mill, 35 were installed and used mainly for cattle watering (sales price US$ 2,200). Of the 5 meter mill, 7 were installed in demonstration projects for small-scale irrigation (sales price US$ 4,000). The production rate of the 3 meter mill at the end of the project was 10 mills per 8 weeks. Production of the 5 meter mill stopped for several reasons, but may go on when adaptations in the mill prove to be effective. Repairs of the traditional mills could not be realized. The overall conclusion is that the achievements of the project were lower than the original objectives for reasons which are formulated in the conclusions. 3 ills

  4. Residual heat removal pump retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; McKenna, J.M.

    1990-01-01

    Residual Heat Removal (RHR) pumps installed in pressurized water reactor power plants are used to provide the removal of decay heat from the reactor and to provide low head safety injection in the event of loss of coolant in the reactor coolant system. These pumps are subjected to rather severe temperature and pressure transients, therefore, the majority of pumps installed in the RHR service are vertical pumps with a single stage impeller. RHR pumps have traditionally been a significant maintenance item for many utilities. The close-coupled pump design requires disassembly of the casing cover from the lower pump casing while performing these routine maintenance tasks. The casing separation requires the loosening of numerous highly torqued studs. Once the casing is separated, the impeller is dropped from the motor shaft to allow removal of the mechanical seal and casing cover from the motor shaft. Galling of the impeller to the motor shaft is not uncommon. The RHR pump internals are radioactive and the separation of the pump casing to perform routine maintenance exposes the maintenance personnel to high radiation levels. The handling of the impeller also exposes the maintenance personnel to high radiation levels. This paper introduces a design modification developed to convert the close-coupled RHR pumps to a coupled configuration

  5. Ventricular distension and diastolic coronary blood flow in the anaesthetized dog.

    Science.gov (United States)

    Gattullo, D; Linden, R J; Losano, G; Pagliaro, P; Westerhof, N

    1993-01-01

    There appears to be no agreement as to whether or not an increase in diastolic left ventricular pressure and/or volume can cause a decrease in diastolic coronary blood flow. We investigated the problem in the anaesthetized dog using a flaccid freely distensible latex balloon inserted into the left ventricle with the animal on extracorporeal circulation and the coronary perfusion pressure constant at about 45 mm Hg. Maximal vasodilatation and suppression of autoregulation in coronary vasculature was obtained by the intracoronary infusion of dipyridamole (10-40 mg/h). Ventricular volume was changed in steps of 10 ml from 10 to 70 ml and back to 10 ml, whilst recording coronary blood flow and left ventricular pressure in the left circumflex coronary artery. Over a range of ventricular volumes from 20 to 50 ml and a concomitant rise in diastolic ventricular pressure to about 20 mm Hg there was no change in the diastolic coronary flow. Only when the ventricular volume was more than two times the control value (i.e. exceeded 50 ml) and left ventricular pressure was more than 20 mm Hg, was there a decrease in coronary flow. During the return of the volume to the control level there was a fall in diastolic flow and ventricular contractility with respect to the values obtained when the volume was increased; these two effects were transient lasting less than 10 min. It was not considered that any of the three models of the coronary circulation, waterfall, intramyocardial pump or varying elastance model could explain our results.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Heat pumps: planning, optimisation, operation and maintenance; Waermepumpen. Planung - Optimierung - Betrieb - Wartung

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, P. [Kunz-Beratungen, Dietlikon (Switzerland); Afjei, T. [Fachhochschule Nordwestschweiz, Institut fuer Energie am Bau, Muttenz (Switzerland); Betschart, W.; Prochaska, V. [Hochschule Luzern, Technik und Architektur, Horw (Switzerland); Hubacher, P. [Hubacher Engineering, Engelburg (Switzerland); Loehrer, R. [Scheco AG, Winterthur (Switzerland); Mueller, A. [Mueller und Pletscher AG, Winterthur (Switzerland)

    2008-01-15

    This handbook issued by the Swiss Federal Office of Energy (SFOE) in co-operation with a trade publication takes a look at the planning, optimisation, operation and maintenance of heat pumps. First of all, the basics of heat pump technology, heat pump components and refrigerants are discussed. Then, heat sources and heat distribution are looked at, followed by chapters on the integration of heat pumps into heating systems and noise protection topics. The definition of projects, commissioning and operation of heat pump systems are then discussed. Examples of installations round off the handbook.

  7. Treatment strategies in the left main coronary artery disease associated with acute coronary syndromes

    Directory of Open Access Journals (Sweden)

    Ahmet Karabulut

    2015-10-01

    Full Text Available Significant left main coronary artery (LMCA stenosis is not rare and reported 3 to 10% of patients undergoing coronary angiography. Unprotected LMCA intervention is a still clinical challenge and surgery is still going to be a traditional management method in many cardiac centers. With a presentation of drug eluting stent (DES, extensive use of IVUS and skilled operators, number of such interventions increased rapidly which lead to change in recommendation in the guidelines regarding LMCA procedures in the stable angina (Class 2a recommendation for ostial and shaft lesion and class 2b recommendation for distal bifurcation lesion. However, there was not clear consensus about the management of unprotected LMCA lesion associated with acute myocardial infarction (MI with a LMCA culprit lesion itself or distinct culprit lesion of other major coronary arteries. Surgery could be preferred as an obligatory management strategy even in the high risk patients. With this review, we aimed to demonstrate treatment strategies of LMCA disease associated with acute coronary syndrome, particularly acute myocardial infarction (MI. In addition, we presented a short case series with LMCA lesion and ST elevated acute MI in which culprit lesion placed either in the left anterior descending artery or circumflex artery. We reviewed the current medical literature and propose simple algorithm for management.

  8. Dependence of Intramyocardial Pressure and Coronary Flow on Ventricular Loading and Contractility: A Model Study

    NARCIS (Netherlands)

    Bovendeerd, P.H.M.; Borsje, P.; Arts, M.G.J.; Vosse, van de F.N.

    2006-01-01

    The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of

  9. Hourly simulation of a Ground-Coupled Heat Pump system

    Science.gov (United States)

    Naldi, C.; Zanchini, E.

    2017-01-01

    In this paper, we present a MATLAB code for the hourly simulation of a whole Ground-Coupled Heat Pump (GCHP) system, based on the g-functions previously obtained by Zanchini and Lazzari. The code applies both to on-off heat pumps and to inverter-driven ones. It is employed to analyse the effects of the inverter and of the total length of the Borehole Heat Exchanger (BHE) field on the mean seasonal COP (SCOP) and on the mean seasonal EER (SEER) of a GCHP system designed for a residential house with 6 apartments in Bologna, North-Center Italy, with dominant heating loads. A BHE field with 3 in line boreholes is considered, with length of each BHE either 75 m or 105 m. The results show that the increase of the BHE length yields a SCOP enhancement of about 7%, while the SEER remains nearly unchanged. The replacement of the on-off heat pump by an inverter-driven one yields a SCOP enhancement of about 30% and a SEER enhancement of about 50%. The results demonstrate the importance of employing inverter-driven heat pumps for GCHP systems.

  10. Particles pumping in Tore Supra

    International Nuclear Information System (INIS)

    Bonnel, P.; Chappuis, P.; Lipa, M.

    1989-01-01

    TORE SUPRA and its peripheral equipments are provided with routine clean high vacuum by turbomolecular pumping. During plasma discharges large quantity of very hot gases activating at plasma edge and plasma density in scrape off layer has to be controlled before they strike violently solid wall provoking increase in impurities content and make density up to disruptive level. A Magnetic Ergodic Divertor made of six winding structures - MED - six Vertical Pumped Limiters - VPL - and one Horizontal Pumped Limiter - HPL - are set in the vacuum chamber in order to cope with plasma-wall interactions and neutral gas recycling. Each apparatus is equipped at front side with thermal shield respectively made of polycristallin and pyrolitic graphite bolted on stainless steel support for MED and HPL whereas for VPL it is made of CFC Aerolor 05 brazed on hardened copper. The total heat removal capacity of these plasma facing components is 12 MW. Design of particles collection openings and ducts conductance allow 10% of capture efficiency, that means for TORE SUPRA a flux of 3 x 10 21 particles/second has to be sorbed by water cooled titanium getter pumps, settled at rear side. All those facilities were put into plasma operation at the beginning of 1989 for a short time. Preliminary observations go along with theoretical predictions, that actions in scrappe-off layer may provoke effects in bulk plasma. Very first results drawn out, show that particle collection and heat removal were effective by MED, VPL and HPL and that plasma behaviour was not disturbed by their presence and actions but instead tendency to improvement was observed

  11. Impact of Lesion Length on Functional Significance in Intermediate Coronary Lesions

    Directory of Open Access Journals (Sweden)

    Morteza Safi

    2017-07-01

    Full Text Available Introduction: The present study aimed at assessing the role of lesion length in predicting Fractional Flow Reserve (FFR value for physiological evaluation of intermediate coronary lesions.Methods: In the current study, 68 patients with 83 coronary lesions were enrolled. All of the patients in this study underwent routine coronary angiography, according to appropriate indications. To evaluate physiologically significant intermediate coronary stenosis (defined between 40% and 70% on visual estimation, the Fractional Flow Reserve (FFR study was performed and the Quantitative Coronary Angiography (QCA data were also assessed for measurement of lesion length. The correlation between QCA data and FFR values was also examined.Results: Eighty-three lesions were evaluated from 68 patients. Stenosis was considered physiologically significant when FFR was lower than 0.75. The FFR was significant in twelve lesions (14.5%. There was a negative correlation between FFR value and lesion length (r = -0.294 and P = 0.013. Moreover, lesion length in physiologically significant FFR group (21.07  ± 6.9 was greater than that of the non-significant FFR group (15.23 ± 6.5 (P value < 0.05. Furthermore, the correlation between QCA data and FFR values was also investigated, yet, there was only a positive correlation between FFR and Minimum Luminal Diameter (MLD values (r = 0.248 and P value = 0.04. The Receiver Operating Characteristic (ROC curve analysis for predicting the significant FFR value demonstrated that a lesion length greater than 17.5 mm was the best cut-off point for prediction of the significant FFR value with acceptable sensitivity and specificity of 83.3% and 68.8%, respectively.Conclusions: There is a negative correlation between lesion length and FFR value in intermediate coronary lesions. In addition, a lesion length greater than 17.5 mm is the best cut- off point for prediction of significant FFR values.

  12. Energy Efficient Pump Control for an Offshore Oil Processing System

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Soleiman, Kian; Løhndorf, Bo

    2012-01-01

    The energy efficient control of a pump system for an offshore oil processing system is investigated. The seawater is lifted up by a pump system which consists of three identical centrifugal pumps in parallel, and the lifted seawater is used to cool down the crude oil flowing out of a threephase...... separator on one of the Danish north-sea platform. A hierarchical pump-speed control strategy is developed for the considered system by minimizing the pump power consumption subject to keeping a satisfactory system performance. The proposed control strategy consists of online estimation of some system...... operating parameters, optimization of pump configurations, and a real-time feedback control. Comparing with the current control strategy at the considered system, where the pump system is on/off controlled, and the seawater flows are controlled by a number of control valves, the proposed control strategy...

  13. Browse Title Index

    African Journals Online (AJOL)

    Items 1 - 50 of 81 ... ... afraid of Information Regarding the Complications of Spinal anaesthesia? ... Vol 11, No 1 (2011), Assessment of Knowledge of Cardiopulmonary .... Vol 15, No 1 (2015), Off-pump Coronary Artery Bypass Graft in a High Risk ...

  14. [As cardioprotective and angiogenic biomarker, can ghrelin predict coronary collateral development and severity of coronary atherosclerosis?

    Science.gov (United States)

    Akboğa, Mehmet Kadri; Taçoy, Gülten; Yılmaz Demirtaş, Canan; Türkoğlu, Sedat; Boyacı, Bülent; Çengel, Atiye

    2017-06-01

    Ghrelin exerts protective effects on cardiovascular system by inhibiting progression of atherosclerosis, supression of vascular inflammation, and stimulating angiogenesis. Thus, the aim of this study was to investigate the effect of serum ghrelin on coronary collateral development and SYNTAX score in patients with severe coronary artery disease. Total of 91 patients who had ≥90% stenosis in at least one major coronary artery were prospectively included in this cross-sectional, observational study. Collateral degree was graded according to Rentrop-Cohen classification. Patients with grade 2 or 3 collateral degree were allocated to Good Collateral Group and patients with grade 0 or 1 collateral degree were included in Poor Collateral Group. Ghrelin and vascular endothelial growth factor A (VEGF-A) levels were measured using radioimmunoassay and ELISA kits. Serum ghrelin and VEGF-A levels were significantly higher in Good Collateral Group. Furthermore, ghrelin level showed significant inverse correlation with SYNTAX score (r=0.348; p=0.001). In multivariable regression analysis, ghrelin (Odds ratio, 1.013; 95% confidence interval, 1.011-1.017; p=0.013), VEGF-A, fasting plasma glucose and presence of chronic total occlusion were independent predictors of good collateral development. In receiver operating characteristic curve analysis, ghrelin value cut-off point of ≥781 pg/mL predicted good collateral development with sensitivity of 73.1% and specificity of 67.7%. Findings suggested that ghrelin has antioxidant and antiinflammatory properties that protect endothelial functions and also stimulate angiogenesis, which results in development of good coronary collateral and inhibition of progression of coronary atherosclerosis.

  15. Flue gas condensing with heat pump; Roekgaskondensering med vaermepump

    Energy Technology Data Exchange (ETDEWEB)

    Axby, Fredrik; Pettersson, Camilla [Carl Bro Energikonsult AB, Malmoe (Sweden)

    2004-11-01

    Flue gas condensing is often both a technically and economically efficient method to increase the thermal efficiency in a plant using fuels with high moisture and/or high hydrogen content. The temperature of the return water in district heating systems in Sweden is normally 50 deg C, which gives quite high efficiency for a flue gas condenser. The flue gas after the flue gas condenser still contains energy that to some extent can be recovered by a combustion air humidifier or a heat pump. The object of this project is to technically and economically analyse flue gas condensing with heat pump. The aim is that plant owners get basic data to evaluate if a coupling between a flue gas condenser and a heat pump could be of interest for their plant. With a heat pump the district heating water can be 'sub cooled' to increase the heat recover in the flue gas condenser and thereby increase the total efficiency. The project is set up as a case study of three different plants that represent different types of technologies and sizes; Aabyverket in Oerebro, Amagerforbraending in Copenhagen and Staffanstorp district heating central. In this report a system with a partial flow through the condenser of the heat pump is studied. For each plant one case with the smallest heat pump and a total optimization regarding total efficiency and cost for investment has been calculated. In addition to the optimizations sensitivity analyzes has been done of the following parameters: Moisture in fuel; Type of heat pump; Temperature of the return water in the district heating system; and, Size of plant. The calculations shows that the total efficiency increases with about 6 % by the installation of the heat pump at a temperature of the return water in the district heating system of 50 deg C at Aabyverket. The cost for production of heat is just below 210 kr/MWh and the straight time for pay-off is 5,4 years at 250 kr/MWh in heat credit and at 300 kr/MWh in basic price for electricity. The

  16. Comparison of traditional cardiovascular risk models and coronary atherosclerotic plaque as detected by computed tomography for prediction of acute coronary syndrome in patients with acute chest pain.

    Science.gov (United States)

    Ferencik, Maros; Schlett, Christopher L; Bamberg, Fabian; Truong, Quynh A; Nichols, John H; Pena, Antonio J; Shapiro, Michael D; Rogers, Ian S; Seneviratne, Sujith; Parry, Blair Alden; Cury, Ricardo C; Brady, Thomas J; Brown, David F; Nagurney, John T; Hoffmann, Udo

    2012-08-01

    The objective was to determine the association of four clinical risk scores and coronary plaque burden as detected by computed tomography (CT) with the outcome of acute coronary syndrome (ACS) in patients with acute chest pain. The hypothesis was that the combination of risk scores and plaque burden improved the discriminatory capacity for the diagnosis of ACS. The study was a subanalysis of the Rule Out Myocardial Infarction Using Computer-Assisted Tomography (ROMICAT) trial-a prospective observational cohort study. The authors enrolled patients presenting to the emergency department (ED) with a chief complaint of acute chest pain, inconclusive initial evaluation (negative biomarkers, nondiagnostic electrocardiogram [ECG]), and no history of coronary artery disease (CAD). Patients underwent contrast-enhanced 64-multidetector-row cardiac CT and received standard clinical care (serial ECG, cardiac biomarkers, and subsequent diagnostic testing, such as exercise treadmill testing, nuclear stress perfusion imaging, and/or invasive coronary angiography), as deemed clinically appropriate. The clinical providers were blinded to CT results. The chest pain score was calculated and the results were dichotomized to ≥10 (high-risk) and modeling was performed to examine the association of risk scores and coronary plaque burden to the outcome of ACS. Unadjusted models were individually fitted for the coronary plaque burden and for Goldman, Sanchis, TIMI, and chest pain scores. In adjusted analyses, the authors tested whether the association between risk scores and ACS persisted after controlling for the coronary plaque burden. The prognostic discriminatory capacity of the risk scores and plaque burden for ACS was assessed using c-statistics. The differences in area under the receiver-operating characteristic curve (AUC) and c-statistics were tested by performing the -2 log likelihood ratio test of nested models. A p value capacity for the diagnosis of ACS. Plaque burden was

  17. Pressurizer pump reliability analysis high flux isotope reactor

    International Nuclear Information System (INIS)

    Merryman, L.; Christie, B.

    1993-01-01

    During a prolonged outage from November 1986 to May 1990, numerous changes were made at the High Flux Isotope Reactor (HFIR). Some of these changes involved the pressurizer pumps. An analysis was performed to calculate the impact of these changes on the pressurizer system availability. The analysis showed that the availability of the pressurizer system dropped from essentially 100% to approximately 96%. The primary reason for the decrease in availability comes because off-site power grid disturbances sometimes result in a reactor trip with the present pressurizer pump configuration. Changes are being made to the present pressurizer pump configuration to regain some of the lost availability

  18. Comparative analysis of traditional and alternative energy sources

    Directory of Open Access Journals (Sweden)

    Adriana Csikósová

    2008-11-01

    Full Text Available The presented thesis with designation of Comparing analysis of traditional and alternative energy resources includes, on basisof theoretical information source, research in firm, internal data, trends in company development and market, descriptionof the problem and its application. Theoretical information source is dedicated to the traditional and alternative energy resources,reserves of it, trends in using and development, the balance of it in the world, EU and in Slovakia as well. Analysis of the thesisis reflecting profile of the company and the thermal pump market evaluation using General Electric method. While the companyis implementing, except other products, the thermal pumps on geothermal energy base and surround energy base (air, the missionof the comparing analysis is to compare traditional energy resources with thermal pump from the ecological, utility and economic sideof it. The results of the comparing analysis are resumed in to the SWOT analysis. The part of the thesis includes he questionnaire offerfor effectiveness improvement and customer satisfaction analysis, and expected possibilities of alternative energy resources assistance(benefits from the government and EU funds.

  19. A Fourier Approximation Method for the Multi-Pump Multi-Piston Power Take-Off System

    NARCIS (Netherlands)

    Wei, Yanji; Barradas Berglind, Jose de Jesus; Muhammad Zaki Almuzakki, M.; van Rooij, Marijn; Wang, Ruoqi; Jayawardhana, Bayu; Vakis, Antonis I.

    2018-01-01

    In this work, a frequency-domain method for the numerical solution of the nonlinear dynamics of a wave energy converter with a pumping system is presented. To this end, a finite Fourier series is used to describe the nonlinear force components, i.e., the pumping force. The dynamics of the buoy and

  20. Off-design performance analysis of Kalina cycle for low temperature geothermal source

    International Nuclear Information System (INIS)

    Li, Hang; Hu, Dongshuai; Wang, Mingkun; Dai, Yiping

    2016-01-01

    Highlights: • The off-design performance analysis of Kalina cycle is conducted. • The off-design models are established. • The genetic algorithm is used in the design phase. • The sliding pressure control strategy is applied. - Abstract: Low temperature geothermal sources with brilliant prospects have attracted more and more people’s attention. Kalina cycle system using ammonia water as working fluid could exploit geothermal energy effectively. In this paper, the quantitative analysis of off-design performance of Kalina cycle for the low temperature geothermal source is conducted. The off-design models including turbine, pump and heat exchangers are established preliminarily. Genetic algorithm is used to maximize the net power output and determine the thermodynamic parameters in the design phase. The sliding pressure control strategy applied widely in existing Rankine cycle power plants is adopted to response to the variations of geothermal source mass flow rate ratio (70–120%), geothermal source temperature (116–128 °C) and heat sink temperature (0–35 °C). In the off-design research scopes, the guidance for pump rotational speed adjustment is listed to provide some reference for off-design operation of geothermal power plants. The required adjustment rate of pump rotational speed is more sensitive to per unit geothermal source temperature than per unit heat sink temperature. Influence of the heat sink variation is greater than that of the geothermal source variation on the ranges of net power output and thermal efficiency.

  1. Dependence of intramyocardial pressure and coronary flow on ventricular loading and contractility: a model study.

    Science.gov (United States)

    Bovendeerd, Peter H M; Borsje, Petra; Arts, Theo; van De Vosse, Frans N

    2006-12-01

    The phasic coronary arterial inflow during the normal cardiac cycle has been explained with simple (waterfall, intramyocardial pump) models, emphasizing the role of ventricular pressure. To explain changes in isovolumic and low afterload beats, these models were extended with the effect of three-dimensional wall stress, nonlinear characteristics of the coronary bed, and extravascular fluid exchange. With the associated increase in the number of model parameters, a detailed parameter sensitivity analysis has become difficult. Therefore we investigated the primary relations between ventricular pressure and volume, wall stress, intramyocardial pressure and coronary blood flow, with a mathematical model with a limited number of parameters. The model replicates several experimental observations: the phasic character of coronary inflow is virtually independent of maximum ventricular pressure, the amplitude of the coronary flow signal varies about proportionally with cardiac contractility, and intramyocardial pressure in the ventricular wall may exceed ventricular pressure. A parameter sensitivity analysis shows that the normalized amplitude of coronary inflow is mainly determined by contractility, reflected in ventricular pressure and, at low ventricular volumes, radial wall stress. Normalized flow amplitude is less sensitive to myocardial coronary compliance and resistance, and to the relation between active fiber stress, time, and sarcomere shortening velocity.

  2. Design and optimisation of dual-mode heat pump systems using natural fluids

    International Nuclear Information System (INIS)

    Zhang Wenling; Klemeš, Jiří Jaromír; Kim, Jin-Kuk

    2012-01-01

    The paper introduces new multi-period modelling and design methodology for dual-mode heat pumps using natural fluids. First, a mathematical model is developed to capture thermodynamic and operating characteristics of dual-mode heat pump systems, subject to different ambient temperatures. The multi-period optimisation framework has been developed to reflect different ambient conditions and its influences on heat pump performance, as well as to determine a system capacity of heat pump which allows systematic economic trade-offs between supplementary heating (or cooling) and operating cost for heat pump. Case study considering three geographical locations with different heating and cooling demands is presented to illustrate the importance of using multi-period optimisation for the design of heat pump systems.

  3. Relationship between serum visfatin levels and coronary slow-flow phenomenon.

    Science.gov (United States)

    Cakmak, Huseyin Altug; Aslan, Serkan; Yalcin, Ahmet Arif; Akturk, Ibrahim Faruk; Yalcin, Burce; Uzun, Fatih; Ozturk, Derya; Erturk, Mehmet; Gul, Mehmet

    2015-09-01

    Increased levels of visfatin, a novel adipocytokine, are reported in atherosclerosis, obesity, and type 2 diabetes. The aim of the present study was to investigate the relationship between coronary slow flow (CSF) and visfatin in patients undergoing elective coronary angiography for suspected coronary artery disease. A total of 140 recruited participants (90 patients with CSF and 50 controls) were divided into two groups according to their coronary flow rates. Coronary flow was quantified by thrombolysis in myocardial infarction (TIMI) frame count (TFC). Serum visfatin levels were higher in the CSF group than in the control group (3.29 ± 1.11 vs. 2.70 ± 1.08 ng/ml, p = 0.003). A significant correlation was found between TFC and visfatin (r = 0.535, p < 0.001). The area under the receiver operating characteristic curve was 0.720 (95 % confidence interval, 0.622-0.817, p < 0.001) for visfatin in the diagnosis of CSF. If a cut-off value of 2.59 ng/ml was used, higher levels of visfatin could predict the presence of CSF with 78.9 % sensitivity and 64.0 % specificity. Visfatin levels might be a useful biomarker for predicting CSF in patients undergoing diagnostic coronary angiography.

  4. [Clinical research of minimal extracorporeal circulation in perioperative blood conservation of coronary artery bypass graft].

    Science.gov (United States)

    Liu, Yan; Cui, Hu-jun; Tao, Liang; Chen, Xu-fa

    2011-04-01

    To analyze the clinical effect of minimal extracorporeal circulation (MECC) in blood conservation perioperatively coronary artery bypass graft (CABG). The data of 120 cases received simple CABG since August 2006 to October 2009 was analyzed retrospectively. All the patients were divided to three groups according to the mode of circulation support in-operation: MECC, conventional extracorporeal circulation (cECC) or off-pump, 40 cases in each group. Jostra MECC system with normal temperature was used in MECC group, and common membrane oxygenator with moderate hypo-temperature was used in cECC group. Collect the data of coagulation and the blood cytological examination perioperatively, the draining volume during the first 24 h after operation, and consumption of blood products perioperatively. Standard and logistic EuroSCORE were higher in MECC group than the others (P blood products in cECC group, but no difference among the three groups. MECC could reduce the ruin to blood cell and interfere to coagulation function during the conventional ECC procedure, decrease the postoperative draining volume and requirement of blood products.

  5. Domestic demand-side management (DSM): Role of heat pumps and thermal energy storage (TES) systems

    International Nuclear Information System (INIS)

    Arteconi, A.; Hewitt, N.J.; Polonara, F.

    2013-01-01

    Heat pumps are seen as a promising technology for load management in the built environment, in combination with the smart grid concept. They can be coupled with thermal energy storage (TES) systems to shift electrical loads from high-peak to off-peak hours, thus serving as a powerful tool in demand-side management (DSM). This paper analyzes heat pumps with radiators or underfloor heating distribution systems coupled with TES with a view to showing how a heat pump system behaves and how it influences the building occupants' thermal comfort under a DSM strategy designed to flatten the shape of the electricity load curve by switching off the heat pump during peak hours (16:00–19:00). The reference scenario for the analysis was Northern Ireland (UK). The results showed that the heat pump is a good tool for the purposes of DSM, also thanks to the use of TES systems, in particular with heating distribution systems that have a low thermal inertia, e.g. radiators. It proved possible to achieve a good control of the indoor temperature, even if the heat pump was turned off for 3 h, and to reduce the electricity bill if a “time of use” tariff structure was adopted. -- Highlights: ► Heat pump heating systems with thermal energy storage are considered. ► System behavior is investigated during a DSM strategy for reducing peak energy demand. ► Heat pump heating systems demonstrate to be able to have an active role in DSM programs. ► A TES system must be coupled with the heat pump in presence of low thermal inertia heating distribution systems. ► Central role played by incentives schemes to promote this technology

  6. Role of Acid and Weakly Acidic Reflux in Gastroesophageal Reflux Disease Off Proton Pump Inhibitor Therapy

    Science.gov (United States)

    Sung, Hea Jung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye

    2012-01-01

    Background/Aims Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. Methods We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. The characteristics of acid and weakly acidic reflux were evaluated. Symptomatic and asymptomatic reflux were compared according to GERD subtypes and individual symptoms. Results Forty-two patients (22 males, mean age 46 years) were diagnosed as GERD (17 erosive reflux disease, 9 pH(+) non-erosive reflux disease [NERD], 9 hypersensitive esophagus and 7 symptomatic NERD). A total of 1,725 reflux episodes were detected (855 acid [50%], 857 weakly acidic [50%] and 13 weakly alkaline reflux [reflux was more frequently symptomatic and bolus clearance was longer compared with weakly acidic reflux. In terms of globus, weakly acidic reflux was more symptomatic. Symptomatic reflux was more frequently acid and mixed reflux; these associations were more pronounced in erosive reflux disease and symptomatic NERD. The perception of regurgitation was related to acid reflux, while that of globus was more related to weakly acidic reflux. Conclusions In patients not taking PPI, acid reflux was more frequently symptomatic and had longer bolus clearance. Symptomatic reflux was more frequently acid and mixed type; however, weakly acidic reflux was associated more with globus. These data suggest a role for impedance-pH data in the evaluation of globus. PMID:22837877

  7. Role of Acid and weakly acidic reflux in gastroesophageal reflux disease off proton pump inhibitor therapy.

    Science.gov (United States)

    Sung, Hea Jung; Cho, Yu Kyung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye

    2012-07-01

    Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. The characteristics of acid and weakly acidic reflux were evaluated. Symptomatic and asymptomatic reflux were compared according to GERD subtypes and individual symptoms. Forty-two patients (22 males, mean age 46 years) were diagnosed as GERD (17 erosive reflux disease, 9 pH(+) non-erosive reflux disease [NERD], 9 hypersensitive esophagus and 7 symptomatic NERD). A total of 1,725 reflux episodes were detected (855 acid [50%], 857 weakly acidic [50%] and 13 weakly alkaline reflux [Acid reflux was more frequently symptomatic and bolus clearance was longer compared with weakly acidic reflux. In terms of globus, weakly acidic reflux was more symptomatic. Symptomatic reflux was more frequently acid and mixed reflux; these associations were more pronounced in erosive reflux disease and symptomatic NERD. The perception of regurgitation was related to acid reflux, while that of globus was more related to weakly acidic reflux. In patients not taking PPI, acid reflux was more frequently symptomatic and had longer bolus clearance. Symptomatic reflux was more frequently acid and mixed type; however, weakly acidic reflux was associated more with globus. These data suggest a role for impedance-pH data in the evaluation of globus.

  8. Tokamak advanced pump limiter experiments and analysis

    International Nuclear Information System (INIS)

    Conn, R.W.

    1983-06-01

    Experiments with pump limiter modules on several operating tokamaks establish such limiters as efficient collectors of particles and has demonstrated the importance of ballistic scattering as predicted theoretically. Plasma interaction with recycling neutral gas appears to become important as the plasma density increases and the effective ionization mean free path within the module decreases. In limiters with particle collection but without active internal pumping, the neutral gas pressure is found to vary nonlinearly with the edge plasma density at the highest densities studies. Both experiments and theory indicate that the energy spectrum of gas atoms in the pump ducting is non-thermal, consistent with the results of Monte Carlo neutral atom transport calculations. The distribution of plasma power over the front surface of such modules has been measured and appears to be consistent with the predictions of simple theory. Initial results from the latest experiment on the ISX-B tokamak with an actively pumped limiter module demonstrates that the core plasma density can be controlled with a pump limiter and that the scrape-off layer plasma can partially screen the core plasma from gas injection. The results from module pump limiter experiments and from the theory and design analysis of advanced pump limiters for reactors are used to suggest the major features of a definitive, axisymmetric, toroidal belt pump limiter experiment

  9. Diagnostic value of CRP and Lp(a) in coronary heart disease.

    Science.gov (United States)

    Erbağci, Ayşe Binnur; Tarakçioğlu, Mehmet; Aksoy, Mehmet; Kocabaş, Ramazan; Nacak, Muradiye; Aynacioğlu, A Sükrü; Sivrikoz, Cumhur

    2002-06-01

    Increased lipoprotein (a) [Lp(a)] concentration was reported to be an independent risk factor for coronary heart disease (CHD). Recent epidemiological studies affirmed the value of C-reactive protein (CRP) as the strongest, univariate predictor of the cardiovascular events. We decided to establish cut-off levels providing maximum diagnostic efficiency for CHD. In this study we measured CRP and Lp(a) concentrations in patients with angiographically demonstrated CHD (group A, n: 120), patients without any angiographically demonstrable lesion (group B, n: 62) and a group of healthy subjects (group C, n: 41). Data were evaluated correcting for lipid and lipoprotein concentrations, diabetes mellitus, hypertension, smoking, age, and body mass index in men and women. ROC curve based cut-off values (comparing group A versus groups B and C) and associated diagnostic performances of the assays were evaluated. Significant increases were noted in serum CRP concentrations in men and women, in groups A vs. B,A vs. C, B vs. C. Lp(a) concentrations were not different among groups in men but were higher in group A vs. B and C in women. Optimal cut-off levels for CRP in women and men were found as 2.1 and 3.0 mg/l with the diagnostic values of 0.792 and 0.770, respectively. For Lp(a) optimal cut-off levels were found as 22.6 and 9.8 mg/dl with the diagnostic values of 0.612 and 0.596 in women and men, respectively. The CRP level is quite efficient for separation of patients from controls. Therefore keeping in mind the lack of specificity, the CRP level may be a useful tool in the diagnosis of coronary heart disease. However, the Lp(a) level is not efficient enough to support the use of Lp(a) measurement for management of coronary heart disease.

  10. Applied research of Primary Pump Mission Profile construction

    International Nuclear Information System (INIS)

    Zheng, Gang-yang; Zhang, Zhi-jian; Ye, Quan-liu; Du, Zhi-hao; Ma, Ying-fei; Zhang, Hua-zhi

    2017-01-01

    Highlights: • Minimum Associated Subtask (MAS) and Minimum Effective Component (MEC) are presented in Mission Profile analysis. • Via applying MAS and MEC, Mission Profile plays a more important role in complex system reliability analysis. • Mission Profile has already been used in the reliability analysis of localized Chinese 1000 MW NPP Primary Pump. - Abstract: The traditional Mission Profile analysis did not clarify the accurate concept of minimum subtask and component. However, there are several components, which could be the influencing key element of the system reliability; and there are several subtasks, which could be used as a basic and crucial mission. In this paper, traditional method of Mission Profile has been extended by incorporating two new ideas: Minimum Associated Subtask (MAS) and Minimum Effective Component (MEC). This method of Mission Profile modeling is derived from Chinese 1000 MW NPP Primary Pump localization. A case study on Primary Pump reliability has been presented; then, MAS and MEC have been existed as vital elements in its lifecycle profile construction. By means of MAS and MEC, Mission Profile plays a more important role on complex system (Primary Pump) reliability analysis.

  11. Feasibility analysis of heat pump dryer to dry hawthorn cake

    International Nuclear Information System (INIS)

    Wang, D.C.; Zhang, G.; Han, Y.P.; Zhang, J.P.; Tian, X.L.

    2011-01-01

    Highlights: → A heat pump dryer (HPD) is effectively proposed to dry hawthorn cake-likely materials. → Low drying temperature and high COP of heat pump are obtained in drying beginning. → HPD is more effective, economic than a traditional hot air dryer. → Feasibility of the HPD is also validated by the operation economy estimation. - Abstract: A heat pump dryer (HPD) would be an economic, environmentally friendly, hygienic drying machine used to dry some food, such as hawthorn cakes. Based on the production process of the hawthorn cake, a HPD is proposed and its basic principle is introduced. The experimental drying curves of the hawthorn cake using the heat pump drying method and the traditional hot air drying method are compared and analyzed. The drying process of hawthorn cakes is similar to that of the other drying materials. The higher drying temperature causes a faster drying process. But in the initial stage of the heat pump drying process, the water content of the hawthorn cake is not sensitive to the drying temperature, so a lower drying air temperature can be available in order to get a higher coefficient of performance (COP) of the heat pump (HP). The experimental results and the economic analysis indicate that the HPD is feasibly used to dry hawthorn cakes.

  12. Feasibility analysis of heat pump dryer to dry hawthorn cake

    Energy Technology Data Exchange (ETDEWEB)

    Wang, D.C., E-mail: wdechang@163.com [College of Electromechanical Engineering, Qingdao University, Qingdao 266071 (China); Zhang, G.; Han, Y.P.; Zhang, J.P.; Tian, X.L. [College of Electromechanical Engineering, Qingdao University, Qingdao 266071 (China)

    2011-08-15

    Highlights: {yields} A heat pump dryer (HPD) is effectively proposed to dry hawthorn cake-likely materials. {yields} Low drying temperature and high COP of heat pump are obtained in drying beginning. {yields} HPD is more effective, economic than a traditional hot air dryer. {yields} Feasibility of the HPD is also validated by the operation economy estimation. - Abstract: A heat pump dryer (HPD) would be an economic, environmentally friendly, hygienic drying machine used to dry some food, such as hawthorn cakes. Based on the production process of the hawthorn cake, a HPD is proposed and its basic principle is introduced. The experimental drying curves of the hawthorn cake using the heat pump drying method and the traditional hot air drying method are compared and analyzed. The drying process of hawthorn cakes is similar to that of the other drying materials. The higher drying temperature causes a faster drying process. But in the initial stage of the heat pump drying process, the water content of the hawthorn cake is not sensitive to the drying temperature, so a lower drying air temperature can be available in order to get a higher coefficient of performance (COP) of the heat pump (HP). The experimental results and the economic analysis indicate that the HPD is feasibly used to dry hawthorn cakes.

  13. The economics of supplying the supplementary heat in a closed loop water source heat pump system

    International Nuclear Information System (INIS)

    Johnson, R.P.; Bartkus, V.E.; Singh, J.B.

    1993-01-01

    The paper describes the details of a research and demonstration project that will be completed in August 1992 at a healthcare facility in northeastern Pennsylvania. The purpose of the project is to compare the economics of several methods of supplying the supplementary heating in a facility served by a closed loop water source heat pump system. The systems being tested include a storage hot water tank with electric resistance heaters and three air source heat pumps that have the ability to supply the same heat during on-peak hours as well as off-peak hours. The paper compares the projected operating costs of the following: (1) Gas boiler supplying the supplementary heat. (2) Stored hot water supplying the supplementary heat which is generated and stored during off-peak hours using resistance heat on PP ampersand L's offpeak rate. (3) Stored hot water supplying the supplementary heat generated during off-peak hours using the air source heat pumps on PP ampersand L's off-peak rate. (4) Hot water generated by the air source heat pumps supplying the supplementary loop heating on PP ampersand L's general service and time-of-day electric rates. It is generally known in the HVAC industry that a closed loop water source heat pump system can provide one of the most efficient means of space conditioning to a building with high internal gains by transferring the excess heat available in one part of the building to another part of the building where it may be needed for heating. The following flow diagram depicts the relationship of the air source heat pumps with the storage tanks and the building closed water loop

  14. Review of pump suction reducer selection: Eccentric or concentric reducers

    OpenAIRE

    Mahaffey, R M; van Vuuren, S J

    2014-01-01

    Eccentric reducers are traditionally recommended for the pump suction reducer fitting to allow for transportation of air through the fitting to the pump. The ability of a concentric reducer to provide an improved approach flow to the pump while still allowing air to be transported through the fitting is investigated. Computational fluid dynamics (CFD) were utilised to analyse six concentric and six eccentric reducer geometries at four different inlet velocities to determine the flow velocity ...

  15. Modelling of Split Condenser Heat Pump: Optimization and Exergy Analysis

    DEFF Research Database (Denmark)

    Christensen, Stefan Wuust; Elmegaard, Brian; Markussen, Wiebke Brix

    2017-01-01

    This paper presents a numerical study of a split condenser heat pump (SCHP). The SCHP setup differs from a traditional heat pump (THP) setup in the way that two separate water streams on the secondary side of the condenser are heated in parallel to different temperature levels, whereas only one...

  16. Effects of the reactor coolant pumps following a small break in a Westinghouse PWR

    International Nuclear Information System (INIS)

    Koenig, J.E.

    1983-10-01

    Numerical simulations of the thermal-hydraulic events following a small cold-leg break in a Westinghouse pressurized water reactor were performed to address the pumps-on/off issue. The mode of pump operation was varied in each calculation to ascertain the optimum mode. It was found that pump operation was not critical for this break size and location because the fuel rods remained cool in all accidents analyzed. In terms of system mass, however, it was preferable to leave the pumps in operation

  17. Assessment of coronary artery disease by post-mortem cardiac MR

    International Nuclear Information System (INIS)

    Ruder, Thomas D.; Bauer-Kreutz, Regula; Ampanozi, Garyfalia; Rosskopf, Andrea B.; Pilgrim, Thomas M.; Weber, Oliver M.; Thali, Michael J.; Hatch, Gary M.

    2012-01-01

    Objectives: Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease. Methods: We retrospectively compared autopsy and CT findings of 30 cases with significant (≥75%), insignificant (<75%), or absent coronary artery stenosis to post-mortem cardiac MR findings. The chi-square test was used to investigate if the occurrence of CSA depends on the presence or absence of stenosis. Sensitivity, specificity and predictive values were calculated for each finding. Results: CSA indicates the absence of (significant) stenosis (p < 0.001). The occurrence of paired dark bands in lieu of CSA on post-mortem cardiac MR suggests (significant) coronary arteries stenosis (p < 0.001). Both findings have a high specificity but low sensitivity. Conclusions: CSA is a marker of vessel patency. The presence of paired dark bands indicates stenosis. These criteria improve the ability of minimally invasive or virtual autopsy to detect coronary artery disease related deaths

  18. Off-stream Pumped Storage Hydropower plant to increase renewable energy penetration in Santiago Island, Cape Verde

    Science.gov (United States)

    Barreira, Inês; Gueifão, Carlos; Ferreira de Jesus, J.

    2017-04-01

    In order to reduce the high dependence on imported fuels and to meet the ongoing growth of electricity demand, Cape Verde government set the goal to increase renewable energy penetration in Santiago Island until 2020. To help maximize renewable energy penetration, an off-stream Pumped Storage Hydropower (PSH) plant will be installed in Santiago, in one of the following locations: Chã Gonçalves, Mato Sancho and Ribeira dos Picos. This paper summarizes the studies carried out to find the optimal location and connection point of the PSH plant in Santiago’s electricity network. This goal was achieved by assessing the impact of the PSH plant, in each location, on power system stability. The simulation tool PSS/E of Siemens was used to study the steady-state and dynamic behavior of the future (2020) Santiago MV grid. Different scenarios of demand and renewable resources were created. Each hydro unit of the PSH plant was modeled as an adjustable speed reversible turbine employing a DFIM. The results show that Santiago’s grid with the PSH plant in Chã Gonçalves is the one that has the best performance.

  19. Study of Pumping Capacity of Pitched Blade Impellers

    Directory of Open Access Journals (Sweden)

    I. Fořt

    2002-01-01

    Full Text Available A study was made of the pumping capacity of pitched blade impellers in a cylindrical pilot plant vessel with four standard radial baffles at the wall under a turbulent regime of flow. The pumping capacity was calculated from the radial profile of the axial flow, under the assumption of axial symmetry of the discharge flow. The mean velocity was measured using laser Doppler anemometry in a transparent vessel of diameter T = 400 mm, provided with a standard dished bottom. Three and six blade pitched blade impellers (the pitch angle varied within the interval a Îá24°; 45°ń of impeller/vessel diameter ratio D/T = 0.36, as well as a three blade pitched blade impeller with folded blades of the same diameter, were tested. The calculated results were compared with the results of experiments mentioned in the literature, above all in cylindrical vessels with a flat bottom. Both arrangements of the agitated system were described by the impeller energetic efficiency, i.e, a criterion including in dimensionless form both the impeller energy consumption (impeller power input and the impeller pumping effect (impeller pumping capacity. It follows from the results obtained with various geometrical configurations that the energetic efficiency of pitched blade impellers is significantly lower for configurations suitable for mixing solid-liquid suspensions (low impeller off bottom clearances than for blending miscible liquids in mixing (higher impeller off bottom clearances.

  20. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  1. Assessment of feasibility of helium ash exhaust and heat removal by pumped-limiter in tokamak fusion reactor

    International Nuclear Information System (INIS)

    Hitoki, Shigehisa; Sugihara, Masayoshi; Saito, Seiji; Fujisawa, Noboru

    1985-01-01

    A detailed calculation of the behavior of fuel and He particles in tokamak reactor with pumped-limiter is performed by one-dimensional tokamak transport code. Energy of neutral particles flowing back from limiter chamber is calculated by two-dimensional Monte Carlo neutral code. Feasibility of He ash exhaust and heat removal by the pumped-limiter are analyzed. Following features of the pumped-limiter are clarified: (1) Electron temperature decays rapidly in radial direction in scrape-off layer, while density profile is broader than that of temperature. (2) Helium accumulation in main plasma can be kept at desired level by rather short limiter and moderate pumping system. (3) Minimum amount of tritium pumped out little depends on limiter length. (4) Although high temperature plasma in scrape-off layer could be realized by large pumping and ideal pellet injection, it is not sufficiently high to reduce the erosion of the limiter surface and the leading edge. In conclusion, He ash exhaust may be possible by the pumped-limiter, while the heat load and erosion will be so high that the pumped-limiter may not be applicable unless the boundary plasma is cooled by radiation or by some other means. (author)

  2. Factors associated with pulmonary dysfunction in patients undergoing coronary artery bypass graft surgery with use of intra-aortic balloon pump.

    Science.gov (United States)

    Amaral Gonçalves Fusatto, Helena; Castilho de Figueiredo, Luciana; Ragonete Dos Anjos Agostini, Ana Paula; Sibinelli, Melissa; Dragosavac, Desanka

    2018-01-01

    The aim of this study was to identify pulmonary dysfunction and factors associated with prolonged mechanical ventilation, hospital stay, weaning failure and mortality in patients undergoing coronary artery bypass grafting with use of intra-aortic balloon pump (IABP). This observational study analyzed respiratory, surgical, clinical and demographic variables and related them to outcomes. We analyzed 39 patients with a mean age of 61.2 years. Pulmonary dysfunction, characterized by mildly impaired gas exchange, was present from the immediate postoperative period to the third postoperative day. Mechanical ventilation time was influenced by the use of IABP and PaO2/FiO2, female gender and smoking. Intensive care unit (ICU) stay was influenced by APACHE II score and use of IABP. Mortality was strongly influenced by APACHE II score, followed by weaning failure. Pulmonary dysfunction was present from the first to the third postoperative day. Mechanical ventilation time was influenced by female gender, smoking, duration of IABP use and PaO2/FiO2 on the first postoperative day. ICU stay was influenced by APACHE II score and duration of IABP. Mortality was influenced by APACHE II score, followed by weaning failure. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Comparative Study between Perfusion Changes and Positive Findings on Coronary Flow Reserve

    Directory of Open Access Journals (Sweden)

    Costantino Roberto Frack Costantini

    Full Text Available Abstract Background: Functional assessment of coronary artery obstruction is used in cardiology practice to correlate anatomic obstructions with flow decrease. Among such assessments, the study of the coronary fractional flow reserve (FFR has become the most widely used. Objective: To evaluate the correlation between FFR and findings of ischemia obtained by noninvasive methods including stress echocardiography and nuclear medicine and the presence of critical coronary artery obstruction. Methods: Retrospective study of cases treated with systematized and standardized procedures for coronary disease between March 2011 and August 2014. We included 96 patients with 107 critical coronary obstructions (> 50% in the coronary trunk and/or ≥ 70% in other segments estimated by quantitative coronary angiography (QCA and intracoronary ultrasound (ICUS. All cases presented ischemia in one of the noninvasive studies. Results: All 96 patients presented ischemia (100% in one of the functional tests. On FFR study with adenosine 140 g/kg/min, 52% of the cases had values ≤ 0.80. On correlation analysis for FFR ≤ 0.80, the evaluation of sensitivity, specificity, positive and negative predictive values, accuracy, and ROC curve in relation to the stenosis degree and length, and presence of ischemia, no significant values or strong correlation were observed. Conclusion: Coronary FFR using a cut-off value of 0.80 showed no correlation with noninvasive ischemia tests in patients with severe coronary artery obstructions on QCA and ICUS.

  4. The Coronary Artery Disease-Reporting and Data System (CAD-RADS): Prognostic and Clinical Implications Associated With Standardized Coronary Computed Tomography Angiography Reporting.

    Science.gov (United States)

    Xie, Joe X; Cury, Ricardo C; Leipsic, Jonathon; Crim, Matthew T; Berman, Daniel S; Gransar, Heidi; Budoff, Matthew J; Achenbach, Stephan; Ó Hartaigh, Bríain; Callister, Tracy Q; Marques, Hugo; Rubinshtein, Ronen; Al-Mallah, Mouaz H; Andreini, Daniele; Pontone, Gianluca; Cademartiri, Filippo; Maffei, Erica; Chinnaiyan, Kavitha; Raff, Gilbert; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Dunning, Allison; DeLago, Augustin; Kim, Yong-Jin; Kaufmann, Philipp A; Villines, Todd C; Chow, Benjamin J W; Hindoyan, Niree; Gomez, Millie; Lin, Fay Y; Jones, Erica; Min, James K; Shaw, Leslee J

    2018-01-01

    This study sought to assess clinical outcomes associated with the novel Coronary Artery Disease-Reporting and Data System (CAD-RADS) scores used to standardize coronary computed tomography angiography (CTA) reporting and their potential utility in guiding post-coronary CTA care. Clinical decision support is a major focus of health care policies aimed at improving guideline-directed care. Recently, CAD-RADS was developed to standardize coronary CTA reporting and includes clinical recommendations to facilitate patient management after coronary CTA. In the multinational CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter) registry, 5,039 patients without known coronary artery disease (CAD) underwent coronary CTA and were stratified by CAD-RADS scores, which rank CAD stenosis severity as 0 (0%), 1 (1% to 24%), 2 (25% to 49%), 3 (50% to 69%), 4A (70% to 99% in 1 to 2 vessels), 4B (70% to 99% in 3 vessels or ≥50% left main), or 5 (100%). Kaplan-Meier and multivariable Cox models were used to estimate all-cause mortality or myocardial infarction (MI). Receiver-operating characteristic (ROC) curves were used to compare CAD-RADS to the Duke CAD Index and traditional CAD classification. Referrals to invasive coronary angiography (ICA) after coronary CTA were also assessed. Cumulative 5-year event-free survival ranged from 95.2% to 69.3% for CAD-RADS 0 to 5 (p data, 57% of CAD-RADS 3 patients who received 30-day ICA were either asymptomatic or not receiving antianginal therapy at baseline, whereas only 32% had angina and were receiving medical therapy. CAD-RADS effectively identified patients at risk for adverse events. Frequent ICA use was observed among patients without severe CAD, many of whom were asymptomatic or not taking antianginal drugs. Incorporating CAD-RADS into coronary CTA reports may provide a novel opportunity to promote evidence-based care post-coronary CTA. Copyright © 2018 American College of Cardiology

  5. Study on cavitation in centrifugal sodium pumps for FBTR and PFBR

    International Nuclear Information System (INIS)

    Rao, A.S.L.K.; Prabhakar, R.; Prakash, V.; Paranjpe, S.R.

    2002-01-01

    Fast Breeder Test Reactor (FBTR) which is expected to become critical shortly is a loop type reactor of 40 MW thermal capacity and has two primary and two secondary centrifugal pumps for heat removal. During the initial periods of reactor operation, the steam generator is bypassed and the secondary sodium pumps are required to operate at flows less than that at best efficiency point. This paper deals with the cavitation problems associated with operation at partial f lows, theoretical estimations and experimental cavitation measurements carried out on FBTR secondary sodium pumps. These investigations revealed that operation of FBTR pumps at this off design condition is free from cavitation damage. Cavitation experiments on a model pump for the development of large sodium pumps for a 500 MWe Prototype Fast Breeder Reactor (PFBR) are described in this paper

  6. Non invasive cardiac vein mapping: Role of multislice CT coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Malago, Roberto, E-mail: robertomalag@yahoo.it [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Pezzato, Andrea; Barbiani, Camilla; Sala, Giuseppe; Zamboni, Giulia A. [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Tavella, Domenico [Cardiology Service, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy); Mucelli, Roberto Pozzi [Radiology Department, University Hospital Policlinico G.B.Rossi, P.le L.A. Scuro 10, 37134 Verona (Italy)

    2012-11-15

    Purpose: Coronary venous anatomy is of primary importance when implanting a cardiac resynchronization therapy device, besides, the coronary sinus can be differently enlarged depending on chronic heart failure. The aim of this study is to evaluate the usefulness of Coronary CTA in describing the coronary venous tree and in particular the coronary sinus and detecting main venous system variants. Materials and methods: 301 consecutive patients (196 Male-Sign , mean age 63.74 years) studied for coronary artery disease with 64 slice Coronary CTA were retrospectively examined. The acquisition protocol was the standard acquisition one used for coronary artery evaluation but the cardiac venous system were visualized. The cardiac venous system was depicted using 3D, MPR, cMPR and MIP post-processing reconstructions on an off-line workstation. For each patient image quality, presence and caliber of the coronary sinus (CS), great cardiac vein (GCV), middle vein (MV), anterior interventricular vein (AIV), lateral cardiac vein (LCV), posterior cardiac vein (PCV), small cardiac vein (SCV) and presence of variant of the normal anatomy were examined and recorded. Results: CS, GCV, MV and AIV were visualized in 100% of the cases. The LCV was visualized in 255/301 (84%) patients, the PCV in 248/301 (83%) patients and the SCV in 69/301 (23%) patients. Mean diameter of the CS was 8.7 mm in 276/301 (91.7%) patients without chronic heart failure and 9.93 mm in 25/301 (8.3%) patients with chronic heart failure. Conclusions: Coronary CTA allows non invasive mapping of the cardiac venous system and may represent a useful presurgical tool for biventricular pacemaker devices implantation.

  7. Giant pseudoaneurysm from Vieussens' arterial ring.

    Science.gov (United States)

    Kocica, Mladen J; Vranes, Mile R; Djukic, Petar L; Mikic, Aleksandar Dj; Velinovic, Milos M; Havelka, Marija; Kanjuh, Vladimir I

    2004-11-01

    A giant coronary pseudoaneurysm of uncertain cause, arising from Vieussens' arterial ring, was preoperatively diagnosed in an oligosymptomatic female patient. Successful off-pump surgical excision without additional bypass grafting was performed. Difficulties in diagnostic algorithm, as well as possible cause and extremely rare localization were discussed.

  8. Diode-pumped continuous-wave eye-safe Nd:YAG laser at 1415 nm.

    Science.gov (United States)

    Lee, Hee Chul; Byeon, Sung Ug; Lukashev, Alexei

    2012-04-01

    We describe the output performance of the 1415 nm emission in Nd:YAG in a plane-concave cavity under traditional pumping into the 4F5/2 level (808 nm) and direct in-band pumping into the 4F3/2 level (885 nm). An end-pumped Nd:YAG laser yielded maximum cw output power of 6.3 W and 4.2 W at 885 nm and 808 nm laser diode (LD) pumping, respectively. To the best of our knowledge, this is the highest output power of a LD-pumped 1415 nm laser.

  9. Design technology development of the main coolant pump for an integral reactor

    International Nuclear Information System (INIS)

    Park, J. S.; Lee, J. S.; Kim, M. H.; Kim, D. W.; Kim, J. I.

    2004-01-01

    All of the reactor coolant pump currently used in commercial nuclear power plant were imported from foreign country. Now, the developing program of design technology for the reactor coolant pump will be started in a few future by domestic researchers. At this stage, the design technology of the main coolant pump for an integral reactor is developed based on the regulation of domestic nuclear power plant facilities. The main coolant pump is a canned motor axial pump, which accommodates all constraints required from the integral reactor system. The main coolant pump does not have mechanical seal device because the rotor of motor and the shaft of impeller are the same one. There is no flywheel on the rotating shaft of main coolant pump so that the coastdown duration time is short when the electricity supply is cut off

  10. Capacitive-discharge-pumped copper bromide vapour laser

    International Nuclear Information System (INIS)

    Sukhanov, V B; Fedorov, V F; Troitskii, V O; Gubarev, F A; Evtushenko, Gennadii S

    2007-01-01

    A copper bromide vapour laser pumped by a high-frequency capacitive discharge is developed. It is shown that, by using of a capacitive discharge, it is possible to built a sealed off metal halide vapour laser of a simple design allowing the addition of active impurities into the working medium. (letters)

  11. Calcified Plaque of Coronary Artery: Factors Influencing Overestimation of Coronary Artery Stenosis on Coronary CT Angiography

    International Nuclear Information System (INIS)

    Kim, Mok Hee; Kim, Yun Hyeon; Choi, Song; Seon, Hyun Ju; Jeong, Gwang Woo; Park, Jin Gyoon; Kang, Heoung Keun; Ko, Joon Seok

    2010-01-01

    To assess the influence of calcified plaque characteristics on the overestimation of coronary arterial stenosis on a coronary CT angiography (CCTA). The study included 271 coronary arteries with calcified plaques identified by CCTA, and based on 928 coronary arteries from 232 patients who underwent both CCTA and invasive coronary angiography (ICA). Individual coronary arteries were classified into two groups by agreement based on the degree of stenosis from each CCTA and ICA: 1) group A includes patients with concordant CCTA and ICA results and, 2) group B includes patients with an overestimation of CCTA compared to ICA. Parameters including total calcium score, calcium score of an individual coronary artery, calcium burden number of an individual coronary artery, and the density of each calcified plaque (calcium score / number of calcium burden) for each individual coronary artery were compared between the two groups. Of the 271 coronary arteries, 164 (60.5%) were overestimated on CCTA. The left anterior descending artery (LAD) had a significantly low rate of overestimation (47.1%) compared to the other coronary arteries (p=0.001). No significant differences for total calcium score, calcium score of individual coronary artery, and the density of each calcified plaque from individual coronary arteries between two groups was observed. However, a decreasing tendency for the rate of overestimation on CCTA was observed with an increase in calcium burden of individual coronary arteries (p<0.05). The evaluation of coronary arteries suggests that the degree of coronary arterial stenosis had a tendency to be overestimated by calcified plaques on CCTA. However, the rate of overestimation for the degree of coronary arterial stenosis by calcified plaques was not significantly influenced by total calcium score, calcium score of individual coronary artery, and density of each calcified plaque

  12. Malignant Multivessel Coronary Spasm Complicated by Myocardial Infarction, Transient Complete Heart Block, Ventricular Fibrillation, Cardiogenic Shock and Ischemic Stroke

    Directory of Open Access Journals (Sweden)

    Viji S. Thomson

    2014-07-01

    Full Text Available Multivessel coronary spasm resulting to cardiogenic shock and malignant ventricular arrhythmias though rare has been reported in the literature. The disease seems to be more prevalent in Asians. There have been isolated reports of coronary spasm in patients with reactive airway disease. We report the first case of spontaneous multivessel spasm in a male patient with bronchial asthma of Arab ethnicity resulting in acute myocardial infarction complicated by cardiogenic shock, recurrent ventricular arrhythmias, and transient complete heart block. Literature review of similar cases suggests a strong association with bronchial asthma and a more malignant course in patients with reactive airway disease. The role of intracoronary nitroglycerin in proving the diagnosis even in patients in shock on maximal inotropic supports and intra-aortic balloon pump is highlighted and the importance of considering multivessel coronary spasm as a cause for acute coronary syndrome even in patients with conventional risk factors for atherosclerotic coronary artery disease is reinforced in the discussion of this case.

  13. Electromagnetically powered electrolytic pump and thermo-responsive valve for drug delivery

    KAUST Repository

    Yi, Ying; Zaher, Amir; Yassine, Omar; Buttner, Ulrich; Kosel, Jü rgen; Foulds, Ian G.

    2015-01-01

    A novel drug delivery device is presented, implementing an electrolytic pump and a thermo-responsive valve. The device is remotely operated by an AC electromagnetic field (40.5∼58.5 mT, 450 kHz) that provides the power for the pump and the valve. It is suitable for long-term therapy applications, which use a solid drug in reservoir (SDR) approach and avoids unwanted drug diffusion. When the electromagnetic field is on, the electrolytic pump drives the drug towards the valve. The valve is made of a magnetic composite consisting of a smart hydrogel: Poly (N-Isopropylacrylamide) (PNIPAm) and iron powder. The heat generated in the iron powder via magnetic losses causes the PNIPAm to shrink, allowing the drug to flow past it. When the electromagnetic field is off, the PNIPAm swells, sealing the outlet. In the meantime, the bubbles generated by electrolysis recombine into water, causing a pressure reduction in the pumping chamber. This draws fresh fluid from outside the pump into the drug reservoir before the valve is fully sealed. The recombination can be accelerated by a platinum (Pt) coated catalytic reformer, allowing more fluid to flow back to the drug reservoir and dissolve the drug. By repeatedly turning on and off the magnetic field, the drug solution can be delivered cyclically. © 2015 IEEE.

  14. Electromagnetically powered electrolytic pump and thermo-responsive valve for drug delivery

    KAUST Repository

    Yi, Ying

    2015-04-01

    A novel drug delivery device is presented, implementing an electrolytic pump and a thermo-responsive valve. The device is remotely operated by an AC electromagnetic field (40.5∼58.5 mT, 450 kHz) that provides the power for the pump and the valve. It is suitable for long-term therapy applications, which use a solid drug in reservoir (SDR) approach and avoids unwanted drug diffusion. When the electromagnetic field is on, the electrolytic pump drives the drug towards the valve. The valve is made of a magnetic composite consisting of a smart hydrogel: Poly (N-Isopropylacrylamide) (PNIPAm) and iron powder. The heat generated in the iron powder via magnetic losses causes the PNIPAm to shrink, allowing the drug to flow past it. When the electromagnetic field is off, the PNIPAm swells, sealing the outlet. In the meantime, the bubbles generated by electrolysis recombine into water, causing a pressure reduction in the pumping chamber. This draws fresh fluid from outside the pump into the drug reservoir before the valve is fully sealed. The recombination can be accelerated by a platinum (Pt) coated catalytic reformer, allowing more fluid to flow back to the drug reservoir and dissolve the drug. By repeatedly turning on and off the magnetic field, the drug solution can be delivered cyclically. © 2015 IEEE.

  15. A mitral annulus tracking approach for navigation of off-pump beating heart mitral valve repair.

    Science.gov (United States)

    Li, Feng P; Rajchl, Martin; Moore, John; Peters, Terry M

    2015-01-01

    To develop and validate a real-time mitral valve annulus (MVA) tracking approach based on biplane transesophageal echocardiogram (TEE) data and magnetic tracking systems (MTS) to be used in minimally invasive off-pump beating heart mitral valve repair (MVR). The authors' guidance system consists of three major components: TEE, magnetic tracking system, and an image guidance software platform. TEE provides real-time intraoperative images to show the cardiac motion and intracardiac surgical tools. The magnetic tracking system tracks the TEE probe and the surgical tools. The software platform integrates the TEE image planes and the virtual model of the tools and the MVA model on the screen. The authors' MVA tracking approach, which aims to update the MVA model in near real-time, comprises of three steps: image based gating, predictive reinitialization, and registration based MVA tracking. The image based gating step uses a small patch centered at each MVA point in the TEE images to identify images at optimal cardiac phases for updating the position of the MVA. The predictive reinitialization step uses the position and orientation of the TEE probe provided by the magnetic tracking system to predict the position of the MVA points in the TEE images and uses them for the initialization of the registration component. The registration based MVA tracking step aims to locate the MVA points in the images selected by the image based gating component by performing image based registration. The validation of the MVA tracking approach was performed in a phantom study and a retrospective study on porcine data. In the phantom study, controlled translations were applied to the phantom and the tracked MVA was compared to its "true" position estimated based on a magnetic sensor attached to the phantom. The MVA tracking accuracy was 1.29 ± 0.58 mm when the translation distance is about 1 cm, and increased to 2.85 ± 1.19 mm when the translation distance is about 3 cm. In the study on

  16. Can perioperative C-reactive protein and interleukin-6 levels predict atrial fibrillation after coronary artery bypass surgery?

    International Nuclear Information System (INIS)

    Ziabaksh-Tabari, S.

    2008-01-01

    Objective was to examine the relationship between proinflammatory cytokines such as interleukin-6 (IL-6) and C-reactive protein (CRP) and atrial fibrillation and after on-pump coronary artery bypass grafting (CABG). Fifty-four patients with coronary artery disease undergoing elective CABG at the Mazandaran Medical University, Mazandaran, Iran were enrolled in our prospective study in the year 2007. Postoperatively, heart rate and rhythm were continuously monitored for 5 days. Fasting blood samples were taken from all patients to examine quantities of CRP and IL-6 the day before surgery and on the second postoperative day in the intensive care unit. From 54 patients, 11 patients (20.4%) developed atrial fibrillation (AF) after CABG. The median age of patients with AF was 51.45+/-10.74 compared with 57.28+/-9.04 for patients with sinus rhythm (p=0.072). Cardioplegic time, cross clamp time and pump time were higher in the AF group but there was no significant difference between the 2 groups. Preoperative CRP and IL-6 levels were higher in patients with AF. The CRP and IL-6 increased after CABG in all patients but it increased more in the AF group. There was a significant relationship between preoperative IL-6 and AF in patients who underwent on-pump CABG, but there was no relationship between CRP and AF. Therefore, administration of glucocordicoids which significantly reduce plasma levels of IL-6 can reduce the incidence of AF after on-pump CABG. (author)

  17. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery.

    Science.gov (United States)

    Maimaituxun, Gulinu; Shimabukuro, Michio; Salim, Hotimah Masdan; Tabata, Minoru; Yuji, Daisuke; Morimoto, Yoshihisa; Akasaka, Takeshi; Matsuura, Tomomi; Yagi, Shusuke; Fukuda, Daiju; Yamada, Hirotsugu; Soeki, Takeshi; Sugimoto, Takaki; Tanaka, Masashi; Takanashi, Shuichiro; Sata, Masataka

    2017-01-01

    Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD) are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV) in patients undergoing coronary artery bypass grafting (CABG) remains unknown. Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57) who underwent CABG or non-coronary valvular surgery (non-CABG). In men, EATV, EATV index (EATV/body surface area) and the markers of adiposity such as body mass index, waist circumference and visceral fat area were higher in the CABG group than in the non-CABG group. Traditional ASCVD risk factors were also prevalent in the CABG group. In women, EATV and EATV index were higher in the CABG group, but other adiposity markers were comparable between CABG and non-CABG groups. Multivariate logistic regression analysis showed that in men, CABG was determined by EATV Index and other ASCVD risk factors including hypertension, dyslipidemia, adiponectin, high sensitive C-reactive protein (hsCRP) and type 2 diabetes mellitus (Corrected R2 = 0.262, p EATV Index (Corrected R2 = 0.266, p = 0.005). Our study found that multiple risk factors, including epicardial adipose tissue volume and traditional ASCVD factors are determinants for CABG in men, but type 2 diabetes mellitus was the sole determinant in women. Gender-specific disparities in risk factors of CABG prompt us to evaluate new diagnostic and treatment strategies and to seek underlying mechanisms.

  18. Primary antiphospholipid syndrome: absence of premature atherosclerosis in patients without traditional coronary artery disease risk factors.

    Science.gov (United States)

    Andrade, D; Bortolotto, L; Bonfá, E; Borba, E

    2016-04-01

    To investigate if patients with Primary Antiphospholipid Syndrome (PAPS) with venous and/or arterial thrombosis without traditional coronary artery disease (CAD) risk factors develop early atherosclerotic vascular damage. 27 female patients with PAPS (Sidney criteria) and 27 age, body mass index (BMI), and sex matched controls were consecutively selected. Exclusion criteria were: black race, age ≥55 years, traditional cardiovascular risk factors, other thrombophilias or connective tissue diseases, corticosteroids use and pregnancy. All subjects underwent Pulse Wave Velocity (PWV) and Echo-Tracking (ET), both in carotidal bed, to analyse vascular functional properties. Age (p = 0.92) and BMI (p = 0.91) were comparable in both groups. PAPS patients and controls had similar PWV (9.07 ± 1.08 m/s vs 9.42 ± 1.47 m/s, p = 0.34) as well as echo tracking parameters such as intima-media thickness (683 ± 171 µm vs 636 ± 140 µm, p = 0.52), carotideal diameter (p = 0.26), distensibility (p = 0.92), compliance coefficients (p = 0.36) and elastic modulus (p = 0.78). Patients with exclusively venous thrombosis showed lower PWV than patients with arterial thrombosis (8.55 ± 0.70 m/s vs 9.56 ± 0.94 m/s, p = 0.01), but no difference regarding intima-media thickness (683 ± 171 µm vs 636 ± 140 µm, p = 0.52) was observed. Patients with PAPS do not seem to be at higher risk of developing premature atherosclerosis. Patients who suffered exclusively venous thrombosis seem to be at lower risk than those with exclusively arterial events. Other studies need to confirm our findings. © The Author(s) 2015.

  19. A reviewof the pharmacologicalmechanism of traditional Chinese ...

    African Journals Online (AJOL)

    A reviewof the pharmacologicalmechanism of traditional Chinese medicine in the intervention of coronary heart disease and stroke. W Zhang, K Gao, K Gao, J Liu, J Liu, H Zhao, H Zhao, J Wang, J Wang, Y Li, Y Li, G Murtaza, G Murtaza, J Chen, J Chen, W Wang, W Wang ...

  20. Generalizability of EXCEL and NOBLE results to a large registry population with unprotected left main coronary artery disease.

    Science.gov (United States)

    Lee, Pil Hyung; Kang, Se Hun; Han, Seungbong; Ahn, Jung-Min; Bae, Jae Seok; Lee, Cheol Hyun; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Park, Duk-Woo; Park, Seung-Jung

    2017-12-01

    The aim of this study was to determine how trial-based findings of EXCEL and NOBLE might be interpreted and generalizable in 'real-world' settings with comparison of data from the large-scaled, all-comer Interventional Research Incorporation Society-Left MAIN Revascularization (IRIS-MAIN) registry. We compared baseline clinical and procedural characteristics and also determined how the relative treatment effect of percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) was different in EXCEL and NOBLE, compared with those of the multicenter, IRIS-MAIN registry (n=2481). The primary outcome for between-study comparison was a composite of death, myocardial infarction (MI), or stroke. There were between-study differences in patient risk profiles (age, BMI, diabetes, and clinical presentation), lesion complexities, and procedural characteristics (stent type, the use of off-pump surgery, and radial artery); the proportion of diabetes and acute coronary syndrome was particularly lower in NOBLE than in other studies. Although there was interstudy heterogeneity for the protocol definition of MI, the risks for serious composite outcome of death, MI, or stroke were similar between PCI and CABG in EXCEL [hazard ratio (HR): 1.00; 95% confidence interval (CI): 0.79-1.26; P=0.98] and in the matched cohort of IRIS-MAIN (HR: 1.08; 95%CI: 0.85-1.38; P=0.53), whereas it was significantly higher after PCI than after CABG in NOBLE (HR: 1.47; 95%CI: 1.06-2.05; P=0.02), which was driven by more common MI and stroke after PCI. In the comparison of a large-sized, all-comer registry, the EXCEL trial might represent better generalizability with respect to baseline characteristics and observed clinical outcomes compared with the NOBLE trial.

  1. Non-traditional inheritance

    International Nuclear Information System (INIS)

    Hall, J.G.

    1992-01-01

    In the last few years, several non-traditional forms of inheritance have been recognized. These include mosaicism, cytoplasmic inheritance, uniparental disomy, imprinting, amplification/anticipation, and somatic recombination. Genomic imprinting (GI) is the dependence of the phenotype on the sex of the transmitting parent. GI in humans seems to involve growth, behaviour, and survival in utero. The detailed mechanism of genomic imprinting is not known, but it seems that some process is involved in turning a gene off; this probably involves two genes, one of which produces a product that turns a gene off, and the gene that is itself turned off. The process of imprinting (turning off) may be associated with methylation. Erasure of imprinting can occur, and seems to be associated with meiosis. 10 refs

  2. Giant narrowband twin-beam generation along the pump-energy propagation direction

    Science.gov (United States)

    Pérez, Angela M.; Spasibko, Kirill Yu; Sharapova, Polina R.; Tikhonova, Olga V.; Leuchs, Gerd; Chekhova, Maria V.

    2015-07-01

    Walk-off effects, originating from the difference between the group and phase velocities, limit the efficiency of nonlinear optical interactions. While transverse walk-off can be eliminated by proper medium engineering, longitudinal walk-off is harder to avoid. In particular, ultrafast twin-beam generation via pulsed parametric down-conversion and four-wave mixing is only possible in short crystals or fibres. Here we show that in high-gain parametric down-conversion, one can overcome the destructive role of both effects and even turn them into useful tools for shaping the emission. In our experiment, one of the twin beams is emitted along the pump Poynting vector or its group velocity matches that of the pump. The result is markedly enhanced generation of both twin beams, with the simultaneous narrowing of angular and frequency spectrum. The effect will enable efficient generation of ultrafast twin photons and beams in cavities, waveguides and whispering-gallery mode resonators.

  3. The minimum coronary artery diameter in which coronary spasm can be identified by synchrotron radiation coronary angiography

    International Nuclear Information System (INIS)

    Matsushita, Shonosuke; Hyodo, Kazuyuki; Imazuru, Tomohiro; Tokunaga, Chiho; Sato, Fujio; Enomoto, Yoshiharu; Hiramatsu, Yuji; Sakakibara, Yuzuru

    2008-01-01

    Background: Coronary vasospasm is defined as a temporary, intense narrowing of the coronary conduit artery. It brings about ischemic chest pain and becomes one of the causes of myocardial infarction. Coronary spasms are divided into two categories. One is the coronary spasm of the conduit artery and the other is the coronary microvascular spasm. Although coronary spasms are diagnosed with the images of coronary angiography, microvascular spasms cannot be diagnosed because of the limitations of conventional angiographic systems. However, synchrotron radiation coronary angiography (SRCA) can identify coronary arteries down to 100 μm in diameter in the beating heart and 50 μm in arrested heart. Aim: The purpose of this study was to confirm whether microvascular spasms could be identified or not using SRCA, and then down that size identification was possible. Methods: The Langendorff perfusion system with isolated rat hearts was employed. Krebs-Henseleit solution (KH solution) was used as a perfusate. 10 mM of 4-aminopyridine (4-AP: a voltage-gated potassium channel blocker; spasm inducer) was added to the KH solution and maintained for 5 min. SRCA was performed at pre-, during and 10 min after cessation of the KH solution with 4-AP. Coronary spasms were defined as a temporal 75% reduction of coronary arterial diameter. Results and conclusion: Multiple sizes of coronary arteries showed coronary spasms. The minimum stenosed coronary artery size was 100 μm. Since coronary microvascular spasms are seen in the arterioles (50-400 μm), coronary microvascular spasms may be diagnosed with the use of synchrotron radiation coronary angiography

  4. Sodium pumping: pump problems

    International Nuclear Information System (INIS)

    Guer, M.; Guiton, P.

    Information on sodium pumps for LMFBR type reactors is presented concerning ring pump design, pool reactor pump design, secondary pumps, sodium bearings, swivel joints of the oscillating annulus, and thermal shock loads

  5. Quantitative angiography of the left anterior descending coronary artery: correlations with pressure gradient and exercise thallium scintigraphy

    International Nuclear Information System (INIS)

    Reiber, J.H.C.; Serruys, P.W.; Slager, C.J.; Erasmus Univ., Rotterdam

    1986-01-01

    In order to evaluate during cardiac catheterization what constitutes a physiologically significant obstruction to blood flow in the human coronary system, computer based quantitative analysis of coronary angiograms was performed in 31 patients with isolated proximal left anterior descending coronary artery disease. The angiographic severity of the stenosis was compared with the transstenotic pressure gradient measured with the dilatation catheter during angioplasty and the results of exercise thallium scintigraphy. A curvilinear relation was found between the pressure gradient across the stenosis (normalized for the mean aortic pressure) and the residual minimal obstruction area (after subtracting the area of the angioplasty catheter). This relation was best fitted by the equation: normalized mean pressure gradient = a + b · log [obstruction area], r = 0.74. The measurements of the percent area stenosis (cut-off 80%) and of the transstenotic pressure gradient (cut-off 0.30) obtained at rest, correctly predicted the occurrence of thallium perfusion defects induced by exercise in 83% of the patients. (Auth.)

  6. Performance of a solar augmented heat pump

    Science.gov (United States)

    Bedinger, A. F. G.; Tomlinson, J. J.; Reid, R. L.; Chaffin, D. J.

    Performance of a residential size solar augmented heat pump is reported for the 1979-1980 heating season. The facility located in Knoxville, Tennessee, has a measured heat load coefficient of 339.5 watt/C (644 BTU/hr- F). The solar augmented heat pump system consists of 7.4 cu m of one inch diameter crushed limestone. The heat pump is a nominal 8.8 KW (2 1/2 ton) high efficiency unit. The system includes electric resistance heaters to give the option of adding thermal energy to the pebble bed storage during utility off-peak periods, thus offering considerable load management capability. A 15 KW electric resistance duct heater is used to add thermal energy to the pebble bin as required during off-peak periods. Hourly thermal performance and on site weather data was taken for the period November 1, 1979, to April 13, 1980. Thermal performance data consists of heat flow summations for all modes of the system, pebble bed temperatures, and space temperature. Weather data consists of dry bulb temperature, dew point temperature, total global insolation (in the plane of the collector), and wind speed and direction. An error analysis was performed and the least accurate of the measurements was determined to be the heat flow at 5%. Solar system thermal performance factor was measured to be 8.77. The heat pump thermal performance factor was 1.64. Total system seasonal performance factor was measured to be 1.66. Using a modified version of TRNSYS, the thermal performance of this system was simulated. When simulation results were compared with data collected onsite, the predicted heat flow and power consumption generally were within experimental accuracy.

  7. Specificities of reactor coolant pumps units with lead and lead-bismuth coolant

    International Nuclear Information System (INIS)

    Beznosov, A.V.; Anotonenkov, M.A.; Bokov, P.A.; Baranova, V.S.; Kustov, M.S.

    2009-01-01

    The analysis results of impact of lead and lead-bismuth coolants specific properties on the coolants flow features in flow channels of the main and auxiliary circulating pumps are presented. Impossibility of cavitation initiation in flow channels of vane pumps pumping lead and lead-bismuth coolants was demonstrated. The experimental research results of discontinuity of heavy liquid metal coolant column were presented and conditions of gas cavitation initiation in coolant flow were discussed. Invalidity of traditional calculation methods of water and sodium coolants circulation pumps calculations for lead and lead-bismuth coolants circulation pumps was substantiated [ru

  8. Optically pumped terahertz sources

    Institute of Scientific and Technical Information of China (English)

    ZHONG Kai; SHI Wei; XU DeGang; LIU PengXiang; WANG YuYe; MEI JiaLin; YAN Chao; FU ShiJie; YAO JianQuan

    2017-01-01

    High-power terahertz (THz) generation in the frequency range of0.1-10 THz has been a fast-developing research area ever since the beginning of the THz boom two decades ago,enabling new technological breakthroughs in spectroscopy,communication,imaging,etc.By using optical (laser) pumping methods with near-or mid-infrared (IR) lasers,flexible and practical THz sources covering the whole THz range can be realized to overcome the shortage of electronic THz sources and now they are playing important roles in THz science and technology.This paper overviews various optically pumped THz sources,including femtosecond laser based ultrafast broadband THz generation,monochromatic widely tunable THz generation,single-mode on-chip THz source from photomixing,and the traditional powerful THz gas lasers.Full descriptions from basic principles to the latest progress are presented and their advantages and disadvantages are discussed as well.It is expected that this review gives a comprehensive reference to researchers in this area and additionally helps newcomers to quickly gain understanding of optically pumped THz sources.

  9. Pumps and pump facilities. 2. ed.

    International Nuclear Information System (INIS)

    Bohl, W.; Bauerfeind, H.; Gutmann, G.; Leuschner, G.; Matthias, H.B.; Mengele, R.; Neumaier, R.; Vetter, G.; Wagner, W.

    1981-01-01

    This book deals with the common fundamental aspects of liquid pumps and gives an exemplary choice of the most important kinds of pumps. The scientific matter is dealt with by means of practical mathematical examples among other ways of presenting the matter. Survey of contents: Division on main operational data of pumps - pipe characteristics - pump characteristics - suction behaviour of the pumps - projecting and operation of rotary pumps - boiler feed pumps - reactor feed pumps - oscillating positive-displacement pumps - eccentric spiral pumps. (orig./GL) [de

  10. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M-C. Morice (Marie-Claude); A.P. Kappetein (Arie Pieter); A. Colombo (Antonio); D.R. Holmes Jr (David); M.J. Mack (Michael); E. Stahle (Elisabeth); T.E. Feldman (Ted); M.J.B.M. van den Brand (Marcel); E.J. Bass (Eric); N. van Dyck (Nic); K. Leadly (Katrin); K.D. Dawkins (Keith); F.W. Mohr (Friedrich)

    2009-01-01

    textabstractBACKGROUND Percutaneous coronary intervention (PCI) involving drug-eluting stents is increasingly used to treat complex coronary artery disease, although coronary-artery bypass grafting (CABG) has been the treatment of choice historically. Our trial compared PCI and CABG for treating

  11. Left coronary to right ventricle fistula in a child: management strategy based on cardiac-gated 64-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Davide; Agnoletti, Gabriella; Bonnet, Damien [University Rene Descartes-Paris V, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, AP-HP, Paris (France); Brunelle, Francis; Ou, Phalla [University Rene Descartes-Paris V, Department of Paediatric Radiology, Hopital Necker-Enfants Malades, AP-HP, Paris (France)

    2008-03-15

    Congenital coronary fistulae are a diagnostic challenge. A prerequisite for best management is accurate anatomical evaluation, traditionally provided by invasive catheter angiography. Multislice CT (MSCT) is an emerging noninvasive technique for coronary artery evaluation. We present a 3-year-old boy and highlight the clinical usefulness of new-generation MSCT to study coronary artery fistulae in children. Multiplanar and 3-D reconstruction offer invaluable information to plan the best therapeutic strategy in this setting. We provide evidence for the expanding clinical role of MSCT for coronary artery imaging in children. (orig.)

  12. Left coronary to right ventricle fistula in a child: management strategy based on cardiac-gated 64-slice CT

    International Nuclear Information System (INIS)

    Marini, Davide; Agnoletti, Gabriella; Bonnet, Damien; Brunelle, Francis; Ou, Phalla

    2008-01-01

    Congenital coronary fistulae are a diagnostic challenge. A prerequisite for best management is accurate anatomical evaluation, traditionally provided by invasive catheter angiography. Multislice CT (MSCT) is an emerging noninvasive technique for coronary artery evaluation. We present a 3-year-old boy and highlight the clinical usefulness of new-generation MSCT to study coronary artery fistulae in children. Multiplanar and 3-D reconstruction offer invaluable information to plan the best therapeutic strategy in this setting. We provide evidence for the expanding clinical role of MSCT for coronary artery imaging in children. (orig.)

  13. River Debris Management System using Off-Grid Photovoltaic Module

    Directory of Open Access Journals (Sweden)

    Saadon Intan Mastura

    2017-01-01

    Full Text Available In Malaysia, Malacca River has long been the tourism attraction in Malacca. However, due to negligence, the river has been polluted by the litters thrown by tourists and even local residents, thus reflects a negative perception on Malacca. Therefore, this paper discusses about a fully automated river debris management system development using a stand-alone photovoltaic system. The concept design is to be stand alone in the river and automatically pull debris towards it for disposal. An off-grid stand-alone photovoltaic solar panel is used as renewable energy source connected to water pump and Arduino Uno microcontroller. The water pump rotates a water wheel and at the same time moves a conveyor belt; which is connected to the water wheel by a gear for debris collection. The solar system sizing suitable for the whole system is shown in this paper. The dumpster barge is equipped with an infrared sensor to monitor maximum height for debris, and instruct Arduino Uno to turn off the water pump. This system is able to power up using solar energy on sunny days and using battery otherwise.

  14. Gender differences in outcomes in patients with acute coronary syndrome in the current era: A review.

    Science.gov (United States)

    Tan, Ying C; Sinclair, Hannah; Ghoorah, Kuldeepa; Teoh, Xuyan; Mehran, Roxana; Kunadian, Vijay

    2016-11-01

    Coronary heart disease is the most common cause of death worldwide. In the United Kingdom in 2010, over 80,000 deaths were attributed to coronary heart disease, and one in 10 female deaths were due to coronary heart disease. Acute coronary syndrome, a subset of coronary heart disease, was responsible for 175,000 inpatient admissions in the United Kingdom in 2012. While men have traditionally been considered to be at higher risk of acute coronary syndrome, various studies have demonstrated that women often suffer from poorer outcomes following an adverse cardiovascular event. This gap is gradually narrowing with the introduction of advanced interventional strategies and pharmacotherapy. However, a better understanding of these differences is of crucial importance for the improvement of the pharmacological and interventional management of acute coronary syndrome and for the development of possible new gender-specific diagnostic and therapeutic options. The goals of this review are to evaluate gender differences in outcomes in patients with acute coronary syndrome in the current era and identify potential mechanisms behind these differences in outcomes following percutaneous coronary intervention.

  15. Impact Of Secondary-Primary Pumps Operating Sequence On The Electrical Power Supply System

    International Nuclear Information System (INIS)

    Suwoto; Rusdiyanto; Kiswanto

    2001-01-01

    The operating procedure of the reactor cooling system has decided that the primary cooling pump should be operated before secondary cooling pump as known primary-secondary pumps operating sequence. This decision is based on consideration that starting current of the primary pump is higher than secondary pump. Therefore, the primary-secondary pumps operating sequence can avoid the power supply system failure. However, this operating procedure has to take a consequence that in case of primary pump failure, the shutdown time period of the reaktor to be longer caused to re operate the primary pump has required that the running secondary pump should be shutted off. To solve this problem, an impact analysis of the secondary-primary pumps operating sequence on the electric power supply system was carried out to identify the revision possibility of the cooling pump operating procedure. The analysis by discussion of the measuring results of the secondary and primary pump starting current related to another electrical loads has been measured. From discussion it can be concluded that secondary-primary pumps operating sequence has no impact to failure in electric power supply system

  16. Prognostic Value of Coronary Computed Tomography Imaging in Patients at High Risk Without Symptoms of Coronary Artery Disease.

    Science.gov (United States)

    Dedic, Admir; Ten Kate, Gert-Jan R; Roos, Cornelis J; Neefjes, Lisan A; de Graaf, Michiel A; Spronk, Angela; Delgado, Victoria; van Lennep, Jeanine E Roeters; Moelker, Adriaan; Ouhlous, Mohamed; Scholte, Arthur J H A; Boersma, Eric; Sijbrands, Eric J G; Nieman, Koen; Bax, Jeroen J; de Feijter, Pim J

    2016-03-01

    At present, traditional risk factors are used to guide cardiovascular management of asymptomatic subjects. Intensified surveillance may be warranted in those identified as high risk of developing cardiovascular disease (CVD). This study aims to determine the prognostic value of coronary computed tomography (CT) angiography (CCTA) next to the coronary artery calcium score (CACS) in patients at high CVD risk without symptoms suspect for coronary artery disease (CAD). A total of 665 patients at high risk (mean age 56 ± 9 years, 417 men), having at least one important CVD risk factor (diabetes mellitus, familial hypercholesterolemia, peripheral artery disease, or severe hypertension) or a calculated European systematic coronary risk evaluation of >10% were included from outpatient clinics at 2 academic centers. Follow-up was performed for the occurrence of adverse events including all-cause mortality, nonfatal myocardial infarction, unstable angina, or coronary revascularization. During a median follow-up of 3.0 (interquartile range 1.3 to 4.1) years, adverse events occurred in 40 subjects (6.0%). By multivariate analysis, adjusted for age, gender, and CACS, obstructive CAD on CCTA (≥50% luminal stenosis) was a significant predictor of adverse events (hazard ratio 5.9 [CI 1.3 to 26.1]). Addition of CCTA to age, gender, plus CACS, increased the C statistic from 0.81 to 0.84 and resulted in a total net reclassification index of 0.19 (p value and risk reclassification benefit beyond CACS in patients without CAD symptoms but with high risk of developing CVD. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Affordable Hybrid Heat Pump Clothes Dryer

    Energy Technology Data Exchange (ETDEWEB)

    TeGrotenhuis, Ward E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Butterfield, Andrew [Jabil, St. Petersburg, FL (United States); Caldwell, Dustin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Crook, Alexander [Jabil, St. Petersburg, FL (United States)

    2016-06-30

    This project was successful in demonstrating the feasibility of a step change in residential clothes dryer energy efficiency by demonstrating heat pump technology capable of 50% energy savings over conventional standard-size electric dryers with comparable drying times. A prototype system was designed from off-the-shelf components that can meet the project’s efficiency goals and are affordable. An experimental prototype system was built based on the design that reached 50% energy savings. Improvements have been identified that will reduce drying times of over 60 minutes to reach the goal of 40 minutes. Nevertheless, the prototype represents a step change in efficiency over heat pump dryers recently introduced to the U.S. market, with 30% improvement in energy efficiency at comparable drying times.

  18. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  19. Case Report of First Angiography-Based On-Line FFR Assessment during Coronary Catheterization.

    Science.gov (United States)

    Kornowski, Ran; Vaknin-Assa, Hana

    2017-01-01

    Fractional flow reserve (FFR), an index of the hemodynamic severity of coronary stenoses, is derived from hyperemic pressure measurements and requires a pressure-monitoring guide wire and hyperemic stimulus. Although it has become the standard of reference for decision-making regarding coronary revascularization, the procedure remains underutilized due to its invasive nature. FFR angio is a novel technology that uses the patient's hemodynamic data and routine angiograms to generate a complete three-dimensional coronary tree, with color-coded display of the FFR values at each point along the vessels. After being proven to be as accurate as invasive FFR measurements in an off-line study, this case report presents the first on-line application of the system in the catheterization lab. Here too, a high concordance between FFR angio and invasive FFR was observed. In light of the demonstrated capabilities of the FFR angio system, it should emerge as an important tool for clinical decision-making regarding revascularization in patients with coronary artery disease.

  20. Case Report of First Angiography-Based On-Line FFR Assessment during Coronary Catheterization

    Directory of Open Access Journals (Sweden)

    Ran Kornowski

    2017-01-01

    Full Text Available Fractional flow reserve (FFR, an index of the hemodynamic severity of coronary stenoses, is derived from hyperemic pressure measurements and requires a pressure-monitoring guide wire and hyperemic stimulus. Although it has become the standard of reference for decision-making regarding coronary revascularization, the procedure remains underutilized due to its invasive nature. FFRangio is a novel technology that uses the patient’s hemodynamic data and routine angiograms to generate a complete three-dimensional coronary tree, with color-coded display of the FFR values at each point along the vessels. After being proven to be as accurate as invasive FFR measurements in an off-line study, this case report presents the first on-line application of the system in the catheterization lab. Here too, a high concordance between FFRangio and invasive FFR was observed. In light of the demonstrated capabilities of the FFRangio system, it should emerge as an important tool for clinical decision-making regarding revascularization in patients with coronary artery disease.

  1. Parallel pumping of a ferromagnetic nanostripe: Confinement quantization and off-resonant driving

    Science.gov (United States)

    Yarbrough, P. M.; Livesey, K. L.

    2018-01-01

    The parametric excitation of spin waves in a rectangular, ferromagnetic nanowire in the parallel pump configuration and with an applied field along the long axis of the wire is studied theoretically, using a semi-classical and semi-analytic Hamiltonian approach. We find that as a function of static applied field strength, there are jumps in the pump power needed to excite thermal spin waves. At these jumps, there is the possibility to non-resonantly excite spin waves near kz = 0. Spin waves with negative or positive group velocity and with different standing wave structures across the wire width can be excited by tuning the applied field. By using a magnetostatic Green's function that depends on both the nanowire's width and thickness—rather than just its aspect ratio—we also find that the threshold field strength varies considerably for nanowires with the same aspect ratio but of different sizes. Comparisons between different methods of calculations are made and the advantages and disadvantages of each are discussed.

  2. Pump-To-Signal Intensity Modulation Transfer Characteristics in FOPAs: Modulation Frequency and Saturation Effect

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Cristofori, Valentina; Lund-Hansen, Toke

    2012-01-01

    This paper reports a comprehensive study of pump- to-signal intensity modulation transfer (IMT) in single-pump fiber optic parametric amplifiers (FOPAs). In particular, the IMT is studied for the first time for high-frequency fluctuations of the pump as well as in the saturated gain regime. The IMT...... cut-off frequency in typical single-pump FOPAs is around 100–200 GHz. The possibilities to shift this frequency based on dispersion and nonlinearities involved in the parametric gain are discussed. The severe IMT to the signal at low modulation frequencies can be suppressed by more than 50...

  3. Cross-talk between cardiac muscle and coronary vasculature.

    Science.gov (United States)

    Westerhof, Nico; Boer, Christa; Lamberts, Regis R; Sipkema, Pieter

    2006-10-01

    The cardiac muscle and the coronary vasculature are in close proximity to each other, and a two-way interaction, called cross-talk, exists. Here we focus on the mechanical aspects of cross-talk including the role of the extracellular matrix. Cardiac muscle affects the coronary vasculature. In diastole, the effect of the cardiac muscle on the coronary vasculature depends on the (changes in) muscle length but appears to be small. In systole, coronary artery inflow is impeded, or even reversed, and venous outflow is augmented. These systolic effects are explained by two mechanisms. The waterfall model and the intramyocardial pump model are based on an intramyocardial pressure, assumed to be proportional to ventricular pressure. They explain the global effects of contraction on coronary flow and the effects of contraction in the layers of the heart wall. The varying elastance model, the muscle shortening and thickening model, and the vascular deformation model are based on direct contact between muscles and vessels. They predict global effects as well as differences on flow in layers and flow heterogeneity due to contraction. The relative contributions of these two mechanisms depend on the wall layer (epi- or endocardial) and type of contraction (isovolumic or shortening). Intramyocardial pressure results from (local) muscle contraction and to what extent the interstitial cavity contracts isovolumically. This explains why small arterioles and venules do not collapse in systole. Coronary vasculature affects the cardiac muscle. In diastole, at physiological ventricular volumes, an increase in coronary perfusion pressure increases ventricular stiffness, but the effect is small. In systole, there are two mechanisms by which coronary perfusion affects cardiac contractility. Increased perfusion pressure increases microvascular volume, thereby opening stretch-activated ion channels, resulting in an increased intracellular Ca2+ transient, which is followed by an increase in Ca

  4. Integral diagnosis of coronary atherosclerosis by coronary multidetector computed tomography and by invasive coronary angiography

    International Nuclear Information System (INIS)

    Llerena Rojas, Luis Roberto; Llerena Rojas, Lorenzo D; Mendoza Rodriguez, Vladimir

    2013-01-01

    Coronary angiography by multidetector computed tomography (CMDCT) visualizes the wall and lumen of coronary arteries. Invasive coronary angiography (INVCA) only visualizes the arterial lumen but with better resolution

  5. Highly sensitive C-reactive protein and male gender are independently related to the severity of coronary disease in patients with metabolic syndrome and an acute coronary event

    Directory of Open Access Journals (Sweden)

    C.M.C. Monteiro

    2010-03-01

    Full Text Available Patients with metabolic syndrome are at high-risk for development of atherosclerosis and cardiovascular events. The objective of this study was to examine the major determinants of coronary disease severity, including those coronary risk factors associated with metabolic syndrome, during the early period after an acute coronary episode. We tested the hypothesis that inflammatory markers, especially highly sensitive C-reactive protein (hsCRP, are related to coronary atherosclerosis, in addition to traditional coronary risk factors. Subjects of both genders aged 30 to 75 years (N = 116 were prospectively included if they had suffered a recent acute coronary syndrome (acute myocardial infarction or unstable angina pectoris requiring hospitalization and if they had metabolic syndrome diagnosed according to the National Cholesterol Education Program/Adult Treatment Panel III. Patients were submitted to a coronary angiography and the burden of atherosclerosis was estimated by the Gensini score. The severity of coronary disease was correlated (Spearman’s or Pearson’s coefficient with gender (r = 0.291, P = 0.008, age (r = 0.218, P = 0.048, hsCRP (r = 0.256, P = 0.020, ApoB/ApoA ratio (r = 0.233, P = 0.041, and carotid intima-media thickness (r = 0.236, P = 0.041. After multiple linear regression, only male gender (P = 0.046 and hsCRP (P = 0.012 remained independently associated with the Gensini score. In this high-risk population, male gender and high levels of hsCRP, two variables that can be easily obtained, were associated with more extensive coronary disease, identifying patients with the highest potential of developing new coronary events.

  6. Hydraulic design and optimization of a modular pump-turbine runner

    International Nuclear Information System (INIS)

    Schleicher, W.C.; Oztekin, A.

    2015-01-01

    Highlights: • A modular pumped-storage scheme using elevated water storage towers is investigated. • The pumped-storage scheme also aides in the wastewater treatment process. • A preliminary hydraulic pump-turbine runner design is created based on existing literature. • The preliminary design is optimized using a response surface optimization methodology. • The performance and flow fields between preliminary and optimized designs are compared. - Abstract: A novel modular pumped-storage scheme is investigated that uses elevated water storage towers and cement pools as the upper and lower reservoirs. The scheme serves a second purpose as part of the wastewater treatment process, providing multiple benefits besides energy storage. A small pumped-storage scheme has been shown to be a competitive energy storage solution for micro renewable energy grids; however, pumped-storage schemes have not been implemented on scales smaller than megawatts. Off-the-shelf runner designs are not available for modular pumped-storage schemes, so a custom runner design is sought. A preliminary hydraulic design for a pump-turbine runner is examined and optimized for increased pumping hydraulic efficiency using a response surface optimization methodology. The hydraulic pumping efficiency was found to have improved by 1.06% at the best efficiency point, while turbine hydraulic efficiency decreased by 0.70% at the turbine best efficiency point. The round-trip efficiency for the system was estimated to be about 78%, which is comparable to larger pumped-storage schemes currently in operation

  7. Energy efficient ammonia heat pump. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Claus; Pijnenburg, B.; Schumann Grindorf, H. [Danish Technological Institute, Aarhus (Denmark); Christensen, Rolf [Alfa Laval, Lund (Sweden); Rasmussen, Bjarne D. [Grundfos, Bjerringbro (Denmark); Gram, S.; Fredborg Jakobsen, D. [Svedan Industri Koeleanlaeg, Greve (Denmark)

    2013-09-15

    The report describes the development of a highly effective ammonia heat pump. Heat pumps play an increasingly important role in the search for more effective use of energy in our society. Highly efficient heat pumps can contribute to reduced energy consumption and improved economy of the systems which they are a part of. An ammonia heat pump with high pressure reciprocating compressor and a novel split condenser was developed to prove potential for efficiency optimization. The split of the condenser in two parts can be utilized to obtain smaller temperature approaches and, thereby, improved heat pump efficiency at an equal heat exchanger area, when compared to the traditional solution with separate condenser and de-superheater. The split condenser design can also be exploited for heating a significant share of the total heating capacity to a temperature far above the condensing temperature. Furthermore, the prototype heat pump was equipped with a plate type evaporator combined with a U-turn separator with a minimum liquid height and a liquid pump with the purpose of creating optimum liquid circulation ratio for the highest possible heat transfer coefficients at the lowest possible pressure drop. The test results successfully confirmed the highest possible efficiency; a COP of 4.3 was obtained when heating water from 40 deg. C to 80 deg. C while operating with evaporating/condensing temperatures of +20 deg C/+73 deg C. (Author)

  8. Pay-off-biased social learning underlies the diffusion of novel extractive foraging traditions in a wild primate

    Science.gov (United States)

    2017-01-01

    The type and variety of learning strategies used by individuals to acquire behaviours in the wild are poorly understood, despite the presence of behavioural traditions in diverse taxa. Social learning strategies such as conformity can be broadly adaptive, but may also retard the spread of adaptive innovations. Strategies like pay-off-biased learning, by contrast, are effective at diffusing new behaviour but may perform poorly when adaptive behaviour is common. We present a field experiment in a wild primate, Cebus capucinus, that introduced a novel food item and documented the innovation and diffusion of successful extraction techniques. We develop a multilevel, Bayesian statistical analysis that allows us to quantify individual-level evidence for different social and individual learning strategies. We find that pay-off-biased and age-biased social learning are primarily responsible for the diffusion of new techniques. We find no evidence of conformity; instead rare techniques receive slightly increased attention. We also find substantial and important variation in individual learning strategies that is patterned by age, with younger individuals being more influenced by both social information and their own individual experience. The aggregate cultural dynamics in turn depend upon the variation in learning strategies and the age structure of the wild population. PMID:28592681

  9. Turbidity maximum formation in a well-mixed macrotidal estuary : The role of tidal pumping

    NARCIS (Netherlands)

    Yu, Q.; Wang, Y.; Gao, J.; Gao, S.; Flemming, B.

    2014-01-01

    Traditionally, vertical circulation (induced by gravity circulation and tidal straining), tidal pumping, and resuspension are suggested as the major processes for the formation and maintenance of the estuarine turbidity maximum (ETM). Due to strong mixing, tidal pumping is considered as the

  10. Commercial Submersible Mixing Pump For SRS Tank Waste Removal - 15223

    International Nuclear Information System (INIS)

    Hubbard, Mike; Herbert, James E.; Scheele, Patrick W.

    2015-01-01

    motor pumps designed to fit within available risers and have significant agitation capabilities to suspend waste solids. Waste removal and closure of two tanks has been accomplished with agitation provided by 3 SMPs installed within the tanks. In 2012, a team was assembled to investigate alternative solids removal technologies to support waste removal for closing tanks. The goal of the team was to find a more cost effective approach that could be used to replace the current mixing pump technology. This team was unable to identify an alternative technology outside of mixing pumps to support waste agitation and removal from SRS waste tanks. However, the team did identify a potentially lower cost mixing pump compared to the baseline SLPs and SMPs. Rather than using the traditional procurement using an engineering specification, the team proposed to seek commercially available submersible mixer pumps (CSMP) as alternatives to SLPs and SMPs. SLPs and SMPs have a high procurement cost and the actual cost of moving pumps between tanks has shown to be significantly higher than the original estimates that justified the reuse of SMPs and SLPs. The team recommended procurement of @@@off-the-shelf@@@ industry pumps which may be available for significant savings, but at an increased risk of failure and reduced operating life in the waste tank. The goal of the CSMP program is to obtain mixing pumps that could mix from bulk waste removal through tank closure and then be abandoned in place as part of tank closure. This paper will present the development, progress and relative advantages of the CSMP.

  11. Saltwater Upconing and Decay Beneath a Well Pumping Above an Interface Zone

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Quanlin; Bear, Jacob; Bensabat, Jacob

    2004-04-20

    Saltwater, or brine, underlies fresh water in many aquifers, with a transition zone separating them. Pumping fresh water by wells located above the transition zone produces upconing of the latter, eventually salinizing the pumped water, forcing shut-off. The salinity of the pumped water depends on the pumping rate, on the location of the well's screen, on the fresh water flow regime, and on the difference in density between fresh and salt water, expressed as a dimensionless factor called density difference factor (DDF). Following the well's shut-off, the upconed saltwater mound undergoes decay, tending to return to the pre-pumping regime. In this paper, the upconing-decay processes in an axially symmetrical system are investigated to discover how they are affected by the DDF and by the dispersivities. The code FEAS-Brine, developed for the simulation of coupled density-dependent flow and salt transport, is used. In this code, the flow equation is solved by the Galer:wqkin finite element method (FEM), while the advective-dispersive salt transport equation is solved in the Eulerian-Lagrangian framework. This code does not suffer from the instability constraint on the Peclet number in the vicinity of the pumping well, where advection dominates the salt transport. Simulation results show that upconing is very sensitive to the DDF, which, in our work, is in the range from 0 (for ideal tracer) to 0.2 (for brine). It is shown that for the DDF of 0.025 (for seawater), local upconing occurs only for low iso-salinity surfaces, while those of high salt concentration, practically, do not shift toward the pumping well. For an ideal tracer, all iso-salinity surfaces rise toward the pumping well. For brine, however, only iso-salinity surfaces of very low salinity upcone towards the pumping well. The decay process is lengthy; it takes a long time for the upconed saltwater to migrate back to the original horizontal transition zone prior to pumping. However, the wider

  12. Primary Percutaneous Coronary Intervention for ST elevation myocardial infarction complicated by Cardiogenic Shock

    International Nuclear Information System (INIS)

    Shaikh, A. H.; Hanif, B.; Pathan, A.; Khan, W.; Hashmani, S.; Raza, M.; Nasir, S.

    2013-01-01

    Objective: To determine the outcomes of primary percutaneous coronary intervention for ST elevation myocardial infarction complicated by cardiogenic shock. Methods: The retrospective study was conducted at the Tabba Heart Institute, a private-sector facility in Karachi. It reviewed the medical records of 56 consecutive patients between January 2009 and June 2011 with acute ST elevation myocardial infarction complicated by cardiogenic shock and subjected to primary percutaneous coronary intervention. The primary end point was in-hospital mortality and its predictors. SPSS 14 was used for statistical analysis. Results: The mean age of the study patients was 63+-11.7 years; 38 (68%) were male; 32 (57%) were hypertensive; and 39 (69%) were diabetic. Most infarcts were anterior in location (n=36; 64%). Besides, 33 (59%) required ventilatory support. Intra-aortic balloon pump was placed in 30 (54%), and 33 (59%) patients had multivessel coronary artery disease. In-hospital mortality occurred in 26 (46%). Multivariate logistic regression analysis showed that age >60 years (p= 0.05), diabetes (p <0.01) and left ventricular ejection fraction <40% (p= 0.01) were independent predictors of in-hospital mortality. Conclusions: Results emphasise the need of aggressive management of patients with cardiogenic shock utilising primary percutaneous coronary intervention as a reperfusion strategy to improve clinical outcomes. (author)

  13. Early menopause predicts future coronary heart disease and stroke: the Multi-Ethnic Study of Atherosclerosis.

    Science.gov (United States)

    Wellons, Melissa; Ouyang, Pamela; Schreiner, Pamela J; Herrington, David M; Vaidya, Dhananjay

    2012-10-01

    Cardiovascular disease is the number one killer of women. Identifying women at risk of cardiovascular disease has tremendous public health importance. Early menopause is associated with increased cardiovascular disease events in some predominantly white populations, but not consistently. Our objective was to determine if self-reported early menopause (menopause at an age menopause (either natural menopause or surgical removal of ovaries at an age menopause. In survival curves, women with early menopause had worse coronary heart disease and stroke-free survival (log rank P = 0.008 and P = 0.0158). In models adjusted for age, race/ethnicity, Multi-ethnic Study Atherosclerosis site, and traditional cardiovascular disease risk factors, this risk for coronary heart disease and stroke remained (hazard ratio, 2.08; 95% CI, 1.17-3.70; and hazard ratio, 2.19; 95% CI, 1.11-4.32, respectively). Early menopause is positively associated with coronary heart disease and stroke in a multiethnic cohort, independent of traditional cardiovascular disease risk factors.

  14. Comparison of different lubricating oil pump systems for combustion engines. Vergleich verschiedener Schmieroelpumpen-Systeme bei Verbrennungsmotoren

    Energy Technology Data Exchange (ETDEWEB)

    Eisenmann, S; Haerle, C; Schreiber, B

    1994-10-01

    The present day and future legislative requirements with regard to fuel consumption and improvement of emission values are forcing the automotive industry to continually improve its technology. However, the investments made in such technical innovations should be set-off by the results. The lubricating oil pump can make an important contribution with optimum design and through the choice of the most adequate pump system. Over the last 17 years, SHW has worked very closely with the automotive industry on the development of lubricating oil pumps. One of the results of this research work is a Suction Regulated Pump (SRP) which distinguishes itself from conventional pumps through its lower drive power. We will proceed to explain this pump system, comparing it with the present day pump systems. (orig.)

  15. Rock bed storage with heat pump. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Remmers, H.E.; Mills, G.L.

    1979-05-01

    The study, Rock Bed Storage with Heat Pump, established the feasibility of mating a heat pump to a rock bed storage to effect optimal performance at the lowest cost in single family residences. The operating characteristics of off-the-shelf components of heat pump/rock bed storage systems were studied, and the results were used to formulate configurations of representative systems. These systems were modeled and subsequently analyzed using the TRNSYS computer program and a life cycle cost analysis program called LCCA. A detailed load model of a baseline house was formulated as part of the TRNSYS analysis. Results of the analysis involved the development of a technique to confine the range of heat pump/rock bed storage systems to those systems which are economical for a specific location and set of economic conditions. Additionally, the results included a comparison of the detailed load model with simple UA models such as the ASHRAE bin method. Several modifications and additions were made to the TRNSYS and LCCA computer programs during the course of the study.

  16. Coronary Plaque Volume and Composition Assessed by Computed Tomography Angiography in Patients With Late-Onset Major Depression

    DEFF Research Database (Denmark)

    Devantier, Torben Albert; Nørgaard, Bjarne Linde; Ovrehus, Kristian Altern

    2013-01-01

    Background: Depression is a stronger predictor for the onset of or death from clinical coronary artery disease than traditional cardiovascular risk factors. The association between depression and coronary artery disease has previously been investigated in non-contrast enhanced computed tomography...... studies with conflicting results. The aim of this study was to further elucidate the depression-coronary artery disease relation by use of coronary computed tomography angiography. Methods: The calcified and noncalcified coronary plaque volumes were determined by semiautomatic volumetric quantification...... with controls (14% vs. 7%, p = 0.044). Correspondingly, having depression was associated with an increased calcified plaque proportion of 11.3 [95% confidence interval: 2.63-20.1; p = 0.012] percentage points after adjustment for demographics and cardiovascular risk factors. Conclusion: The proportion...

  17. Design of a Mechanical NaK Pump for Fission Space Power

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David E.; Godfroy, Thomas

    2011-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid, which has specific pumping requirements. Traditionally, electromagnetic linear induction pumps have been used to provide the required flow and pressure head conditions for NaK systems but they can be limited in performance, efficiency, and number of available vendors. The objective of the project was to develop a mechanical NaK centrifugal pump that takes advantages of technology advances not available in previous liquid metal mechanical pump designs. This paper details the design, build, and performance test of a mechanical NaK pump developed at NASA Marshall Space Flight Center. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  18. Power deposition to the pump limiters in Tore-Supra with ohmic plasmas

    International Nuclear Information System (INIS)

    Guilhem, D.; Chatelier, M.; Chappuis Fleury, I.; Klepper, C.

    1990-01-01

    The modification of power scrape-off-length, λq, and power deposition are studied both with the horizontal limiter alone and with the full set of 7 pump limiters for 1MW ohmic plasmas in TORE-SUPRA. By making spatially resolved infrared surface temperature measurements during the plasma discharge, the magnitude and distribution of the energy flux can be derived. For comparison, the surface temperature of the horizontal pump limiter is calculated with a finite element code using a 3D description of the field lines, an exponential scrape-off-layer, and the pump limiter geometry. From comparison of the infrared images of the limiter we derived that the λq for power deposition was slightly less than 9 mm (±1mm) which is in agreement with the predicted design value of 10 mm. For an 8 seconds discharge, the maximum surface temperature on the horizontal limiter is 450 0 C. Inserting the 7 limiters does not modify λq (which becomes 10 mm). The power is shared by all the limiters and the maximum surface temperature on the horizontal limiter decreased to 320 0 C. These λq values have been independently measured by the integrated energy deposition on the horizontal limiter and other internal structures 5 cm into the scrape-off layer. These values agree with the infrared measurements in the two cases

  19. Impact of Spatial Pumping Patterns on Groundwater Management

    Science.gov (United States)

    Yin, J.; Tsai, F. T. C.

    2017-12-01

    Challenges exist to manage groundwater resources while maintaining a balance between groundwater quantity and quality because of anthropogenic pumping activities as well as complex subsurface environment. In this study, to address the impact of spatial pumping pattern on groundwater management, a mixed integer nonlinear multi-objective model is formulated by integrating three objectives within a management framework to: (i) maximize total groundwater withdrawal from potential wells; (ii) minimize total electricity cost for well pumps; and (iii) attain groundwater level at selected monitoring locations as close as possible to the target level. Binary variables are used in the groundwater management model to control the operative status of pumping wells. The NSGA-II is linked with MODFLOW to solve the multi-objective problem. The proposed method is applied to a groundwater management problem in the complex Baton Rouge aquifer system, southeastern Louisiana. Results show that (a) non-dominated trade-off solutions under various spatial distributions of active pumping wells can be achieved. Each solution is optimal with regard to its corresponding objectives; (b) operative status, locations and pumping rates of pumping wells are significant to influence the distribution of hydraulic head, which in turn influence the optimization results; (c) A wide range of optimal solutions is obtained such that decision makers can select the most appropriate solution through negotiation with different stakeholders. This technique is beneficial to finding out the optimal extent to which three objectives including water supply concern, energy concern and subsidence concern can be balanced.

  20. Performance of a 10 kilowatt wind-electric water pumping system for irrigating crops

    Energy Technology Data Exchange (ETDEWEB)

    Vick, B.D.; Clark, R.N. [Conservation and Production Research Lab., Bushland, TX (United States); Molla, S. [Texas A& M Univ., College Station, TX (United States)

    1997-12-31

    A 10 kW wind-electric water pumping system was tested for field crop irrigation at pumping depths from 50 to 120 m. The wind turbine for this system used a permanent magnet alternator that powered off-the-shelf submersible motors and pumps without the use of an inverter. Pumping performance was determined at the USDA-Agricultural Research Service (ARS), Wind Energy Laboratory in Bushland, TX for the 10 kW wind turbine using a pressure valve and a pressure tank to simulate different pumping depths. Pumping performance was measured for two 10 kW wind turbines of the same type at farms near the cities of Garden City, TX and Stiles, TX. The pumping performance data collected at these actual wells compared favorably with the data collected at the USDA-ARS, Wind Energy Laboratory. If utility generated electricity was accessible, payback on the wind turbine depended on the cost of utility generated electricity and the transmission line extension cost.

  1. Large-scale integration of off-shore wind power and regulation strategies of cogeneration plants in the Danish electricity system

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2005-01-01

    The article analyses how the amount of a small-scale CHP plants and heat pumps and the regulation strategies of these affect the quantity of off-shore wind power that may be integrated into Danish electricity supply......The article analyses how the amount of a small-scale CHP plants and heat pumps and the regulation strategies of these affect the quantity of off-shore wind power that may be integrated into Danish electricity supply...

  2. Ion channels versus ion pumps: the principal difference, in principle.

    Science.gov (United States)

    Gadsby, David C

    2009-05-01

    The incessant traffic of ions across cell membranes is controlled by two kinds of border guards: ion channels and ion pumps. Open channels let selected ions diffuse rapidly down electrical and concentration gradients, whereas ion pumps labour tirelessly to maintain the gradients by consuming energy to slowly move ions thermodynamically uphill. Because of the diametrically opposed tasks and the divergent speeds of channels and pumps, they have traditionally been viewed as completely different entities, as alike as chalk and cheese. But new structural and mechanistic information about both of these classes of molecular machines challenges this comfortable separation and forces its re-evaluation.

  3. Magnetic heat pumping near room temperature

    Science.gov (United States)

    Brown, G. V.

    1976-01-01

    It is shown that magnetic heat pumping can be made practical at room temperature by using a ferromagnetic material with a Curie point at or near operating temperature and an appropriate regenerative thermodynamic cycle. Measurements are performed which show that gadolinium is a resonable working material and it is found that the application of a 7-T magnetic field to gadolinium at the Curie point (293 K) causes a heat release of 4 kJ/kg under isothermal conditions or a temperature rise of 14 K under adiabatic conditions. A regeneration technique can be used to lift the load of the lattice and electronic heat capacities off the magnetic system in order to span a reasonable temperature difference and to pump as much entropy per cycle as possible

  4. Dyslipidaemia and coronary heart disease: nature vs nurture.

    Science.gov (United States)

    Hegele, R A

    In order to enhance health care for patients with coronary heart disease (CHD), genetic markers of susceptibility could be incorporated into a formula for risk evaluation that includes traditional factors. Preventive measures could then be targeted towards 'high-risk' subjects. But can the genetic component be dissected from the environmental component in an intermediate CHD phenotype, such as plasma lipoproteins.

  5. Distal coronary hemoperfusion during percutaneous transluminal coronary angioplasty

    NARCIS (Netherlands)

    Muinck, Ebo Derk de

    1994-01-01

    In this thesis several aspects of passive and active coronary perfusion during coronary angioplasty are investigated. The autoperfusion balloon catheters that were evaluated are the Stack® and the RX-60® catheters (Advanced Cardiovascular Systems, inc., Santa Clara, California, U.S.A). The coronary

  6. A thermoeconomic model of a photovoltaic heat pump

    International Nuclear Information System (INIS)

    Mastrullo, R.; Renno, C.

    2010-01-01

    In this paper the model of a heat pump whose evaporator operates as a photovoltaic collector, is studied. The energy balance equations have been used for some heat pump components, and for each layer of the photovoltaic evaporator: covering glaze, photovoltaic modules, thermal absorber plate, refrigerant tube and insulator. The model has been solved by means of a program using proper simplifications. The system input is represented by the solar radiation intensity and the environment temperature, that influence the output electric power of the photovoltaic modules and the evaporation power. The model results have been obtained referring to the photovoltaic evaporator and the plant operating as heat pump, in terms of the photovoltaic evaporator layers temperatures, the refrigerant fluid properties values in the cycle fundamental points, the thermal and mechanical powers, the efficiencies that characterize the plant performances from the energy, exergy and economic point of view. This study allows to realize a thermoeconomic comparison between a photovoltaic heat pump and a traditional heat pump under the same working conditions.

  7. WEXA: exergy analysis for increasing the efficiency of air/water heat pumps - Final report

    Energy Technology Data Exchange (ETDEWEB)

    Gasser, L.; Wellig, B.; Hilfiker, K.

    2008-04-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a study at the made by the Engineering and Architecture department at the Lucerne University of Applied Sciences and Arts. The subject of the WEXA study (Waermepumpen-Exergie-Analyse - heat pump exergy analysis) is the analysis of the operation of air/water heat-pumps using exergy analysis methods. The basic thermodynamics of heating systems using heat-pumps is discussed. The exergy analyses and exergy balances for the various components and processes of an air/water heat-pump are presented and discussed. Comparisons are presented for heat-pumps with on/off and continuous control systems for their compressors and fans. The paper is concluded with a collection of appendices on the subject.

  8. Pumping behavior of sputter ion pumps

    International Nuclear Information System (INIS)

    Chou, T.S.; McCafferty, D.

    The ultrahigh vacuum requirements of ISABELLE is obtained by distributed pumping stations. Each pumping station consists of 1000 l/s titanium sublimation pump for active gases (N 2 , H 2 , O 2 , CO, etc.), and a 20 l/s sputter ion pump for inert gases (methane, noble gases like He, etc.). The combination of the alarming production rate of methane from titanium sublimation pumps (TSP) and the decreasing pumping speed of sputter ion pumps (SIP) in the ultrahigh vacuum region (UHV) leads us to investigate this problem. In this paper, we first describe the essential physics and chemistry of the SIP in a very clean condition, followed by a discussion of our measuring techniques. Finally measured methane, argon and helium pumping speeds are presented for three different ion pumps in the range of 10 -6 to 10 -11 Torr. The virtues of the best pump are also discussed

  9. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery.

    Directory of Open Access Journals (Sweden)

    Gulinu Maimaituxun

    Full Text Available Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV in patients undergoing coronary artery bypass grafting (CABG remains unknown.Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57 who underwent CABG or non-coronary valvular surgery (non-CABG.In men, EATV, EATV index (EATV/body surface area and the markers of adiposity such as body mass index, waist circumference and visceral fat area were higher in the CABG group than in the non-CABG group. Traditional ASCVD risk factors were also prevalent in the CABG group. In women, EATV and EATV index were higher in the CABG group, but other adiposity markers were comparable between CABG and non-CABG groups. Multivariate logistic regression analysis showed that in men, CABG was determined by EATV Index and other ASCVD risk factors including hypertension, dyslipidemia, adiponectin, high sensitive C-reactive protein (hsCRP and type 2 diabetes mellitus (Corrected R2 = 0.262, p < 0.0001, while in women, type 2 diabetes mellitus is a single strong predictor for CABG, excluding EATV Index (Corrected R2 = 0.266, p = 0.005.Our study found that multiple risk factors, including epicardial adipose tissue volume and traditional ASCVD factors are determinants for CABG in men, but type 2 diabetes mellitus was the sole determinant in women. Gender-specific disparities in risk factors of CABG prompt us to evaluate new diagnostic and treatment strategies and to seek underlying mechanisms.

  10. Numerical Simulation of Tubular Pumping Systems with Different Regulation Methods

    Science.gov (United States)

    Zhu, Honggeng; Zhang, Rentian; Deng, Dongsheng; Feng, Xusong; Yao, Linbi

    2010-06-01

    Since the flow in tubular pumping systems is basically along axial direction and passes symmetrically through the impeller, most satisfying the basic hypotheses in the design of impeller and having higher pumping system efficiency in comparison with vertical pumping system, they are being widely applied to low-head pumping engineering. In a pumping station, the fluctuation of water levels in the sump and discharge pool is most common and at most time the pumping system runs under off-design conditions. Hence, the operation of pump has to be flexibly regulated to meet the needs of flow rates, and the selection of regulation method is as important as that of pump to reduce operation cost and achieve economic operation. In this paper, the three dimensional time-averaged Navier-Stokes equations are closed by RNG κ-ɛ turbulent model, and two tubular pumping systems with different regulation methods, equipped with the same pump model but with different designed system structures, are numerically simulated respectively to predict the pumping system performances and analyze the influence of regulation device and help designers make final decision in the selection of design schemes. The computed results indicate that the pumping system with blade-adjusting device needs longer suction box, and the increased hydraulic loss will lower the pumping system efficiency in the order of 1.5%. The pumping system with permanent magnet motor, by means of variable speed regulation, obtains higher system efficiency partly for shorter suction box and partly for different structure design. Nowadays, the varied speed regulation is realized by varied frequency device, the energy consumption of which is about 3˜4% of output power of the motor. Hence, when the efficiency of variable frequency device is considered, the total pumping system efficiency will probably be lower.

  11. Motor Pump Revolution in Ethiopia: Promises at a Crossroads

    Directory of Open Access Journals (Sweden)

    Mengistu Dessalegn

    2015-06-01

    Full Text Available In sub-Saharan Africa, motor pump irrigation is at an earlier stage than in Asia but is growing rapidly in many countries. The focus of both policy and research in Africa to date has been on facilitating supply chains to make pumps available at a reasonable price. In Africa, pump irrigation is mainly based on two sources: shallow groundwater aquifers and small streams and rivers. Both usually have limited and variable yields. We present a case study from Ethiopia where pump irrigation based on small rivers and streams is expanding rapidly, and draw parallels to experiences in Asia and other African countries. We show that while farmers understand the social nature of community-managed irrigation, they share with policymakers a narrow understanding of pump irrigation as being primarily 'technical'. They perceive pumps as liberating them from the 'social' limitations of traditional communal irrigation. However, the rapid expansion of pump irrigation is leading to increasing competition and conflict over the limited water resource. We analyse the wider implications for Africa of this blindness to the social dimension of pump irrigation and offer suggestions on future policy and applied research to address the problem before it becomes a widespread crisis.

  12. Laser Diode Pumped Solid State Lasers

    Science.gov (United States)

    1987-01-01

    Report N66001-83-C-0071, 17 April 1986, prepared for NOSC. 4.6 W.T. Welford, R. Winston , "The Option of Nonimaging Concentrators ," Academic Press, 1978...by non-imac optics such as reflective or refractive flux concentrators . Simple considerations regarding the optimum pumping configuration, high marks...reduced if the arrays can stand-off from the Nd:YAG laser. As mentioned before, compound parabolic concentrators or refractive optics cat employed to

  13. [Ginseng prescription rules and molecular mechanism in treating coronary heart disease based on data mining and integrative pharmacology].

    Science.gov (United States)

    Li, Sen; Tang, Shi-Huan; Liu, Jin-Ling; Su, Jin; He, Fu-Yuan

    2018-04-01

    The ancient dragon Materia Medica, Compendium of Materia Medica and other works recorded that the main effect of ginseng is tonifying qi. It is reported that the main active ingredient of ginseng is ginsenoside. Modern studies have found that ginseng mono saponins are effective for cardiovascular related diseases. This paper preliminary clarified the efficacy of traditional ginseng-nourishing qi and cardiovascular disease through the traditional Chinese medicine (TCM) inheritance auxiliary platform and integration platform of association of pharmacology. With the help of TCM inheritance auxiliary platform-analysis of "Chinese medicine database", Chinese medicine treatment of modern diseases that ginseng rules, so the traditional effect associated with modern medicine and pharmacology; application integration platform enrichment analysis on the target of drug and gene function, metabolic pathway, to further explore the molecular mechanism of ginseng in the treatment of coronary heart disease, aimed at mining the molecular mechanism of ginseng in the treatment of coronary heart disease. Chinese medicine containing ginseng 307 prescriptions, 87 kinds of disease indications, western medicine disease Chinese medicine therapy for ginseng main coronary heart disease; analysis of molecular mechanism of ginseng pharmacology integration platform for the treatment of coronary heart disease. Ginsenosides(Ra₁, Ra₂, Rb₁, Rb₂, Rg₁, Ro) bind these targets, PRKAA1, PRKAA2, NDUFA4, COX5B, UQCRC1, affect chemokines, non-alcoholic fatty liver, gonadotropin, carbon metabolism, glucose metabolism and other pathways to treat coronary heart disease indirectly. The molecular mechanism of Panax ginseng's multi-component, multi-target and synergistic action is preliminarily elucidated in this paper. Copyright© by the Chinese Pharmaceutical Association.

  14. Evaluation of Blood Hemodynamics in Vascular Grafts after Total Arterial Coronary Revascularization

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Amirghofran

    2016-07-01

    Full Text Available Arterial grafting has increasingly been advocated for the treatment of coronary artery disease in an attempt to improve the long-term results. In the quest to perform routine total arterial revascularization, composite Y graft methods are gaining popularity. The aim of our study was to evaluate whether blood flow in the left internal thoracic artery can provide sufficient perfusion to the entire cardiac muscle per se. Twenty patients with severe coronary artery stenosis who underwent complete arterial coronary revascularization using a composite graft entered our study. Blood flow in thoracic trunk was evaluated in three phases: cross-clamp on, cross-clamp off, and after weaning the patient from cardiopulmonary bypass. Mean arterial blood pressure in the thoracic trunk in these various positions was 62.7±3.7. left internal thora cic artery can provide sufficient blood flow to the cardiac muscles for both rest and exercise conditions.

  15. Photonic crystal fibers for supercontinuum generation pumped by a gain-switched CW fiber laser

    DEFF Research Database (Denmark)

    Larsen, Casper; Noordegraaf, Danny; Hansen, Kim P.

    2012-01-01

    Supercontinuum generation in photonics crystal fibers (PCFs) pumped by CW lasers yields high spectral power density and average power. However, such systems require very high pump power and long nonlinear fibers. By on/off modulating the pump diodes of the fiber laser, the relaxation oscillations...... of the laser can be exploited to enhance the broadening process. The physics behind the supercontinuum generation is investigated by sweeping the fiber length, the zero dispersion wavelength, and the fiber nonlinearity. We show that by applying gain-switching a high average output power of up to 30 W can...

  16. HUMAN CORONARY ARTERIES- A STUDY BASED ON GROSS ANATOMY AND CORONARY CAST

    Directory of Open Access Journals (Sweden)

    Vijayamma K. N

    2018-01-01

    Full Text Available BACKGROUND Present study is an attempt to throw light upon the coronary arterial pattern, variations in arterial distribution and extent of intercoronary anastomosis and arterial preponderance in different age groups. MATERIALS AND METHODS Total of 115 hearts were made use for this study. Ninety hearts were dissected for the gross anatomical study of coronary arteries and 25 hearts including three fetal hearts were used for the coronary cast study. The right and left coronary arteries were traced from aortic sinus along the atrioventricular groove to the area of its termination. The atrial ventricular and septal branches were traced and looked for anastomosis. Coronary casts were prepared by injecting coloured liquid latex through the coronary ostia and the branching pattern and anastomosis were studied. The coronary arterial pattern, extent of distribution of its branches, arterial preponderance and variations were observed. RESULTS It was found that 73 % cases of SA nodal branch arise from right coronary artery and 27 % from circumflex branch of left coronary artery. SA node has dual blood supply from both coronary arteries in 4% cases. Right coronary preponderance was observed in 83% of cases and left coronary preponderance in 11 % cases, and balanced supply in 6% cases. Coronary cast was helpful to understand the branching pattern of vessels, and the anastomosis of small capillaries. It was also seen that all 11 % of left preponderance were seen in male hearts and all of the 31 female hearts dissected were right preponderant. CONCLUSION Coronary arteries are called end arteries functionally. Right coronary artery originates from anterior aortic sinus in all cases except one which takes origin from posterior left aortic sinus along with left coronary artery. Right coronary preponderance is observed in 83% cases. Left coronary artery branching pattern shows variability. Left coronary preponderance was observed in 11% and all cases are male

  17. Pump and treat may be the solution

    International Nuclear Information System (INIS)

    Hoffman, A. H.; Truax, S. K.; Conrad, D.

    1997-01-01

    A case history of a 'pump and treat' system, designed to remediate chlorinated solvents and petroleum hydrocarbons in soil and groundwater resulting from historic leaking of six underground storage tanks, was described. The objective of this paper was two-fold: (1) to call into question the findings of some earlier studies which claimed that 'pump and treat' will not work to remediate impacted groundwater in a timely or cost-effective manner, and (2) to demonstrate that under certain circumstances, at some sites, groundwater 'pump and treat' may be the most appropriate, lowest cost remediation alternative. The paper also demonstrates the applicability of horizontal wells and methods to use soil venting in the saturated zone as opposed to its traditional use in the vadose zone. Details of the design parameters, system characteristics and operation are provided. 2 refs., 2 tabs

  18. An analytical model for neutral and charged particles in closed pump limiter

    International Nuclear Information System (INIS)

    Tokar, M.Z.

    1990-01-01

    In number of modern tokamaks pump limiters are used for control of the edge plasma parameters. In thermonuclear reactor projects pump limiters are considered as a possible alternative or additional for divertor configuration of magnetic field method for unburnt fuel, helium ash and other impurity exhaust. From the point of view of limiter operation efficiency the dependence of neutral particle pressure P g in pumping system on the plasma parameters in the scrape-off layer (SOL) is of importance since an increase of P g will permit to decrease needed pump rate and facilitate solution of reactor technological problems. In connection with this the experimentally observed mode of closed pump limiter operation with strong neutral compression is of great interest. In such a mode P g sharply grows up when the SOL plasma density n s exceeds some critial level. (author) 6 refs., 2 figs

  19. Modeling Optimal Scheduling for Pumping System to Minimize Operation Cost and Enhance Operation Reliability

    Directory of Open Access Journals (Sweden)

    Yin Luo

    2012-01-01

    Full Text Available Traditional pump scheduling models neglect the operation reliability which directly relates with the unscheduled maintenance cost and the wear cost during the operation. Just for this, based on the assumption that the vibration directly relates with the operation reliability and the degree of wear, it could express the operation reliability as the normalization of the vibration level. The characteristic of the vibration with the operation point was studied, it could be concluded that idealized flow versus vibration plot should be a distinct bathtub shape. There is a narrow sweet spot (80 to 100 percent BEP to obtain low vibration levels in this shape, and the vibration also follows similar law with the square of the rotation speed without resonance phenomena. Then, the operation reliability could be modeled as the function of the capacity and rotation speed of the pump and add this function to the traditional model to form the new. And contrast with the tradition method, the result shown that the new model could fix the result produced by the traditional, make the pump operate in low vibration, then the operation reliability could increase and the maintenance cost could decrease.

  20. Evaluation of load case ''switch-off of the high pressure pump of the emergency core cooling system'', measures of verification and in situ-test

    International Nuclear Information System (INIS)

    Trobitz, M.; Mattheis, A.; Kerkhof, K.; Hippelein, K.; Hofstoetter, P.

    1998-01-01

    Within the framework of periodic safety inspection of the Gundremmingen power station (RWE-Bayernwerk - KRB II), the load collectives used for the design of safety-relevant systems and components were checked for their consistency with latest updates of the design basis. It was found that there was no analytical information or study available describing a particular process and its effects, namely switch-off of the high-pressure feedwater pump of the emergency core cooling system. The paper reports the work performed for closing the gap, including preparatory analyses, accompanying measures such as vibration measurements during plant shut-down, as well as the preparation and performance of the in-situ test. The experimental results and the comparative evaluation of calculated and experimental data are presented. (orig./CB) [de

  1. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    Science.gov (United States)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  2. TWO-STAGE HEAT PUMPS FOR ENERGY SAVING TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    A. E. Denysova

    2017-09-01

    Full Text Available The problem of energy saving becomes one of the most important in power engineering. It is caused by exhaustion of world reserves in hydrocarbon fuel, such as gas, oil and coal representing sources of traditional heat supply. Conventional sources have essential shortcomings: low power, ecological and economic efficiencies, that can be eliminated by using alternative methods of power supply, like the considered one: low-temperature natural heat of ground waters of on the basis of heat pump installations application. The heat supply system considered provides an effective use of two stages heat pump installation operating as heat source at ground waters during the lowest ambient temperature period. Proposed is a calculation method of heat pump installations on the basis of groundwater energy. Calculated are the values of electric energy consumption by the compressors’ drive, and the heat supply system transformation coefficient µ for a low-potential source of heat from ground waters allowing to estimate high efficiency of two stages heat pump installations.

  3. Design and principle of operation of the HeartMate PHP (percutaneous heart pump).

    Science.gov (United States)

    Van Mieghem, Nicolas M; Daemen, Joost; den Uil, Corstiaan; Dur, Onur; Joziasse, Linda; Maugenest, Anne-Marie; Fitzgerald, Keif; Parker, Chris; Muller, Paul; van Geuns, Robert-Jan

    2018-02-20

    The HeartMate PHP (percutaneous heart pump) is a second-generation transcatheter axial flow circulatory support system. The collapsible catheter pump is inserted through a 14 Fr sheath, deployed across the aortic valve expanding to 24 Fr and able to deliver up to 5 L/min blood flow at minimum haemolytic risk. As such, this device may be a valuable adjunct to percutaneous coronary intervention (PCI) of challenging lesions in high-risk patients or treatment of cardiogenic shock. This technical report discusses: (i) the HeartMate PHP concept, (ii) the implantation technique, (iii) the haemodynamic performance in an in vitro cardiovascular flow testing set-up, and (iv) preliminary clinical experience. An update on the device, produced by St. Jude Medical/Abbott Laboratories, can be found in the Appendix.

  4. Coronary blood flow and coronary stenosis correlations in ischemic heart patients

    International Nuclear Information System (INIS)

    Manukov, I.

    2003-01-01

    The aim of the study is the assessment of the methodology for the C-TIMI frame count by Gibson for easy and fast determination of the coronary blood flow during a selective coronary angiography. 75 patient have been studied with one-branch affection of the coronary arteries. The criteria for exclusion are: myocardial hypertrophy, valve lesions, myocardial infarction and dyslipidemia. Depending of the characteristics of the coronary stenotic changes, the patients have been divided into two groups: 1) Patients with 'ordinary' stenosis of the coronary artery and 2) Patients with 'complex' stenosis. The severity of the stenotic changes in percents is the same for the two groups - 78%±13% vs 81±12%, respectively. In the first group a pronounced correlation is observed between the severity of the coronary stenosis and the slowing of the coronary blood flow. The 'threshold' stenotic level is 89%. In the second group the lowest value of the coronary stenosis is 73% (p>0.01 vs group 1). No correlation is observed between the severity of the coronary stenosis and the slowing of the coronary blood flow. A conclusion is made that the Gibson method for the assessment of the blood flow is convenient for the daily practice not only for the assessment of the significance of the coronary changes, but also for fast analysis of the achieved reconstruction of the coronary arteries after angioplasty. Additional studies of the significance of the different signs of 'complexity' of the coronary stenosis for the slowing of the blood flow are necessary

  5. A Phase-Controlled Optical Parametric Amplifier Pumped by Two Phase-Distorted Laser Beams

    International Nuclear Information System (INIS)

    Hong-Yan, Ren; Lie-Jia, Qian; Peng, Yuan; He-Yuan, Zhu; Dian-Yuan, Fan

    2010-01-01

    We theoretically study the phase characteristic of optical parametric amplification (OPA) or chirped pulse OPA (OPCPA) pumped by two phase-distorted laser beams. In the two-beam-pumped optical parametric amplification (TBOPA), due to spatial walk-off, both of the pump phase distortions will be partly transferred to signal in a single crystal so as to degrade the signal beam-quality, which will be more serious in high-energy OPCPA. An OPA configuration with a walkoff-compensated crystal pair is demonstrated for reducing the signal phase distortion experienced in the first stage and ensuring the signal phase independent of two pump phase distortions through the second crystal, hence maintaining the signal beam-quality. Such a TBOPA is similar to the conventional quantum laser amplifier by means of eliminating its sensitivity to the phase and number of the pump beams

  6. REMOTE CONTROLLING OF AN AGRICULTURAL PUMP SYSTEM BASED ON THE DUAL TONE MULTI-FREQUENCY (DTMF TECHNIQUE

    Directory of Open Access Journals (Sweden)

    BEZA N. GETU

    2015-10-01

    Full Text Available In modern days, as a result of advances in technology, human beings are interested to remotely control different systems and applications. In this work, telephone signalling technique using Dual Tone Multi-Frequency (DTMF signalling, is used to control switching of electrical loads such as agricultural pumps located in remote areas. A DTMF tone command sent from a transmitting fixed or mobile phone terminal will be used to SWITCH ON/OFF the motors used to pump water for agricultural fields. A processing electronic system at the receiving side is designed to interpret the tone commands and sends an appropriate signal to the motor driving circuit to complete the pump switching states. In the design methodology, it is possible to control several water pumps distributed in a certain agricultural site, however, in this work we considered four pumps and the paper presents the complete electronic design and simulation results at the different stages of the design. The electronic design is based on discrete passive and active electronic components and the system is tested and simulated using Multism program. The results of the simulation show that the design is capable of controlling the switching state of the motors. For a certain DTMF command, it is possible to switch ON/OFF a specific motor pump or all of the four motors.

  7. Application Research on Testing Efficiency of Main Drainage Pump in Coal Mine Using Thermodynamic Theories

    OpenAIRE

    Shang, Deyong

    2017-01-01

    The efficiency of a drainage pump should be tested at regular intervals to master the status of the drainage pump in real time and thus achieve the goal of saving energy. The ultrasonic flowmeter method is traditionally used to measure the flow of the pump. But there are some defects in this kind of method of underground coal mine. This paper first introduces the principle of testing the main drainage pump efficiency in coal mine using thermodynamic theories, then analyzes the energy transfor...

  8. Therapeutic modulation of the natural history of coronary atherosclerosis: lessons learned from serial imaging studies.

    Science.gov (United States)

    Andrews, Jordan; Puri, Rishi; Kataoka, Yu; Nicholls, Stephen J; Psaltis, Peter J

    2016-08-01

    Despite advances in risk prediction, preventive and therapeutic strategies, atherosclerotic cardiovascular disease remains a major public health challenge worldwide, carrying considerable morbidity, mortality and health economic burden. There continues to be a need to better understand the natural history of this disease to guide the development of more effective treatment, integral to which is the rapidly evolving field of coronary artery imaging. Various imaging modalities have been refined to enable detailed visualization of the pathological substrate of atherosclerosis, providing accurate and reproducible measures of coronary plaque burden and composition, including the presence of high-risk characteristics. The serial application of such techniques, including coronary computed tomography angiography (CTA), intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have uncovered important insights into the progression of coronary plaque over time in patients with stable and unstable coronary artery disease (CAD), and its responsiveness to therapeutic interventions. Here we review the use of different imaging modalities for the surveillance of coronary atherosclerosis and the lessons they have provided about the modulation of CAD by both traditional and experimental therapies.

  9. Design and development of a split-evaporator heat-pump system

    Energy Technology Data Exchange (ETDEWEB)

    Somerville, M.H.; Penoncello, S.G.

    1981-12-01

    The designs and experimental results of three types of multiple source heat pumps are presented. The three designs are the parallel evaporator, the series evaporator, and the parallel evaporator with active subcooling, with the parallel evaporator with the active subcooling showing the most promise for solving the problem of defrosting of air evaporators. Three design procedures for multiple source heat pumps were developed. One of these is a hand calculational procedure, the others are computer based. The models are based upon the refrigerant flow rate, rather than the refrigeration effect of the evaporator. The technical results of a detailed analytical and experimental model of the heat transfer rates on a flat plate ice maker are presented. It is shown, both analytically and experimentally, that the temperature of the air surrounding the flat plate ice maker can play a dominant role in the rate of ice formation. A detailed weather analysis for forty cities located throughout the nation was completed. These data were processed to allow easy computation of thermal storage requirements for full, partial, or minimum ACES systems, or upon other design requirements, such as off-peak air conditioning. The results of an innovative ice storage system that is thermally coupled to the earth are described. This system has the potential for meeting both the off-peak air conditioning needs and the thermal storage requirements for the heating cycle. An economic and energy comparison of multiple source heat pumps with ACES, and air-to-air heat pump systems is presented.

  10. [Developments in percutaneous coronary intervention and coronary stents].

    Science.gov (United States)

    Simsek, C; Daemen, J; Zijlstra, F

    2014-01-01

    In The Netherlands, more than 30.000 patients undergo a percutaneous coronary intervention every year, during which a coronary stent implantation will be performed in 90% of the cases. It is estimated that more than 5 million coronary stent implantations will be performed worldwide this year. While these numbers are impressive, however, coronary stents still have as a limitation the possibility of stent thrombosis. This has been and is an important stimulus for the development of both coronary stents, from a bare metal stent via a drug eluting stent to the present-day development of bio-absorbable stents, and anti-platelet drugs,from acenocoumarol to thieropyridines. The possibility of shortening the period of use of this powerful medication by developing new kinds of non-thrombogenic stents would, for example, make it possible to achieve significant reductions in subsequent bleeding during (dental) procedures.

  11. The evaluation of dobutamine 99mTc-MIBI myocardial perfusion imaging in the diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    He Qing; Qu Wanying; Gong Junhui; Zhou Ying

    1996-01-01

    The method and the clinical value of dobutamine stress test as a substitute for exercise test in 99m Tc-MIBI myocardial perfusion imaging was investigated. 40 Patients were intravenously infused with dobutamine through IVAC syringe pumps by incremental doses, and 99m Tc-MIBI was injected at the peak dobutamine heart rate. The myocardial imaging was then performed. The rest myocardial imaging was done after 48 hours. 30 of the 31 patients with coronary heart disease showed reversible perfusion defects in dobutamine 99m Tc-MIBI myocardial perfusion images and 7 of the 9 patients without coronary heart disease showed normal images. The sensitivity of this test was 96.8% and the specificity 77.8%. None of the studies was discontinued due to dobutamine side effect. Dobutamine 99m Tc-MIBI myocardial perfusion imaging is a safe and sensitive method in the diagnosis of coronary heart disease

  12. Technical feasibility and validation of a coronary artery calcium scoring system using CT coronary angiography images

    Energy Technology Data Exchange (ETDEWEB)

    Pavitt, Christopher W. [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Harron, Katie [Institute of Child Health, UCL, Centre for Paediatric Epidemiology and Biostatistics, London (United Kingdom); Lindsay, Alistair C.; Ray, Robin [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Zielke, Sayeh; Rubens, Michael B. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Gordon, Daniel [Royal Marsden Hospital, Department of Physics, London (United Kingdom); Padley, Simon P. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Imperial College, Faculty of Medicine, London (United Kingdom); Nicol, Edward D. [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Imperial College, Faculty of Medicine, London (United Kingdom)

    2016-05-15

    We validate a novel CT coronary angiography (CCTA) coronary calcium scoring system. Calcium was quantified on CCTA images using a new patient-specific attenuation threshold: mean + 2SD of intra-coronary contrast density (HU). Using 335 patient data sets a conversion factor (CF) for predicting CACS from CCTA scores (CCTAS) was derived and validated in a separate cohort (n = 168). Bland-Altman analysis and weighted kappa for MESA centiles and Agatston risk groupings were calculated. Multivariable linear regression yielded a CF: CACS = (1.185 x CCTAS) + (0.002 x CCTAS x attenuation threshold). When applied to CCTA data sets there was excellent correlation (r = 0.95; p < 0.0001) and agreement (mean difference -10.4 [95 % limits of agreement -258.9 to 238.1]) with traditional calcium scores. Agreement was better for calcium scores below 500; however, MESA percentile agreement was better for high risk patients. Risk stratification was excellent (Agatston groups k = 0.88 and MESA centiles k = 0.91). Eliminating the dedicated CACS scan decreased patient radiation exposure by approximately one-third. CCTA calcium scores can accurately predict CACS using a simple, individualized, semiautomated approach reducing acquisition time and radiation exposure when evaluating patients for CAD. This method is not affected by the ROI location, imaging protocol, or tube voltage strengthening its clinical applicability. (orig.)

  13. Design of a Mechanical NaK Pump for Fission Space Power Systems

    Science.gov (United States)

    Mireles, Omar R.; Bradley, David; Godfroy, Thomas

    2010-01-01

    Alkali liquid metal cooled fission reactor concepts are under development for mid-range spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid. Traditionally, linear induction pumps have been used to provide the required flow and head conditions for liquid metal systems but can be limited in performance. This paper details the design, build, and check-out test of a mechanical NaK pump. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

  14. Low plasma edge temperatures for the self-pumped limiter

    International Nuclear Information System (INIS)

    Terry, W.K.; Brooks, J.N.

    1985-03-01

    Transport code calculations have been performed to study the operation of an INTOR-like tokamak plasma from which helium is removed by a self-pumped limiter, which traps helium, but not hydrogen, in its surface layers. To prevent saturation by helium, the surface is renewed by continuous injection of the surface material (vanadium in this study) into the scrape-off layer. The presence of the injected vanadium leads to plasma temperatures well below 50 eV in the scrape-off layer, with supplementary rf heating. Operation in this edge temperature regime is essential for the use of medium- and high-Z limiter coatings

  15. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Directory of Open Access Journals (Sweden)

    Muhammed Bora Demircelik

    2014-06-01

    Full Text Available OBJECTIVE:The aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease.METHODS:The study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing <50% in diameter, Group 2; and obstructive atherosclerosis (luminal narrowing ≥50% in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium. Epicardial adipose tissue thickness (mm was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses.RESULTS:The average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm.CONCLUSION:We showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases.

  16. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan, E-mail: drdemircelik@yahoo.com [Turgut Ozal Univercity, Department of Cardiology, Ankara (Turkey); Bozkurt, Alper; Akin, Kayihan [Turgut Ozal Univercity, Department of Radiology, Ankara (Turkey); Yilmaz, Omer Caglar [Ankara Occupational Diseases Hospital, Department of Cardiology, Ankara (Turkey)

    2014-06-15

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  17. Epicardial adipose tissue and pericoronary fat thickness measured with 64-multidetector computed tomography: potential predictors of the severity of coronary artery disease

    International Nuclear Information System (INIS)

    Demircelik, Muhammed Bora; Gurel, Ozgul Malcok; Selcoki, Yusuf; Atar, Inci Asli; Eryonucu, Beyhan; Bozkurt, Alper; Akin, Kayihan; Yilmaz, Omer Caglar

    2014-01-01

    Objective: the aim of the present study was to investigate the relationship between pericoronary fat and the severity and extent of atherosclerosis, quantified using 64-multidetector computed tomography, in patients with suspected coronary artery disease. Methods: the study population consisted of 131 patients who were clinically referred for noninvasive multislice computed tomography coronary angiography for the evaluation of coronary artery disease. Patients were classified as follows: no atherosclerosis, Group 1; nonobstructive atherosclerosis (luminal narrowing < 50% in diameter), Group 2; and obstructive atherosclerosis (luminal narrowing ≧ 50%) in a single vessel or obstructive atherosclerosis in the left main coronary artery and/or multiple vessels, Group 3. Epicardial adipose tissue was defined as the adipose tissue between the surface of the heart and the visceral layer of the pericardium (visceral epicardium). Epicardial adipose tissue thickness (mm) was determined in the right ventricular anterior free wall. The mean thickness of the pericoronary fat surrounding the three coronary arteries was used for the analyses. Results: the average thickness over all three regions was 13.2 ± 2.1 mm. The pericoronary fat thickness was significantly increased in Group 3 compared with Groups 2 and 1. The epicardial adipose tissue thickness was significantly increased in Group 3 compared with Groups 2 and 1. A receiver operating characteristic curve for obstructive coronary artery disease was assessed to verify the optimum cut-off point for pericoronary fat thickness, which was 13.8 mm. A receiver operating characteristic curve for obstructive coronary artery disease was also assessed to verify the optimum cut-off point for epicardial adipose tissue, which was 6.8 cm. Conclusion: we showed that the epicardial adipose tissue and pericoronary fat thickness scores were higher in patients with obstructive coronary artery diseases. (author)

  18. Application of heterogeneous blading systems is the way for improving efficiency of centrifugal energy pumps

    Science.gov (United States)

    Pochylý, F.; Haluza, M.; Fialová, S.; Dobšáková, L.; Volkov, A. V.; Parygin, A. G.; Naumov, A. V.; Vikhlyantsev, A. A.; Druzhinin, A. A.

    2017-11-01

    The results of independent research implemented by the teams of authors representing the Brno University of technology (Czech Republic) and Moscow Power Engineering Institute National Research University (Russia) are presented and compared. The possibilities for improving the energy efficiency of slow-speed centrifugal pumps (with a specific speed coefficient n s engineering—in thermal power stations, in heat electric-power stations, in nuclear power plants, and in boiler rooms—were investigated. These are supply pumps, condensate pumps, precharge pumps, etc. The pumps with such values of n s are widely used in some technological cycles of oil-and-gas and chemical industries too. The research was focused on achieving the shape of the pump efficiency characteristics providing a significant extension of its effective working zone and increasing its integrated efficiency. The results were obtained based on new approaches to the formation of a blading system of an impeller of a slow-speed centrifugal pump different from the traditional blading system. The analytical dependences illustrating the influence of individual geometry of a blading system on the efficiency were presented. The possibilities of purposeful changing of its structure were demonstrated. It was experimentally confirmed that use of the innovative blading system makes it possible to increase the pump efficiency by 1-4% (in the experiments for the pumps with n s = 33 and 55) and to extend its efficient working zone approximately by 15-20% (in the experiment for the pumps with n s = 33 and 66). The latter is especially important for the supply pumps of NPP power units. The experimental results for all investigated pumps are presented in comparison with the characteristics of the efficiency provided by the blading systems designed by traditional methods.

  19. Evaluation of the restenosis of coronary artery after percutaneous transluminal coronary angioplasty by three-dimensional coronary magnetic resonance angiography

    International Nuclear Information System (INIS)

    Arisaka, Hiraku

    2000-01-01

    Coronary magnetic resonance angiography (MRA) has been recently brought into clinical use, however, there has not been reports on the comparison with MRA and conventional contrast coronary angiography (CAG) in the detection of the localization and characteristics of coronary restenosis after percutaneous transluminal coronary angioplasty (PTCA). To assess the restenosis of coronary artery after PTCA, this study compared three-dimensional (3D) coronary MRA and CAG. One hundred three patients (76 males and 27 females, average age of 64.6±9.3 years old) were performed coronary MRA at 3-6 months after PTCA. The right coronary artery (RCA) group consist of 21 patients, the left anterior descending branch (LAD) 63 patients and the left circumflex branch (LCX) 19 patients. Coronary MRA was performed with the patients in supine position on a 1.5 T whole body scanner (MAGNETOM VISION, Siemens AG, Germany) using body array coil. The imaging technique used a 3-D gradient echo sequence with respiratory gating and fat suppression. The slice thickness was 2 mm, slab thickness 32 mm, a field of view of 300 mm and a matrix of 128 x 256. Other parameters were an echo time of 2.7 ms and a repetition time of 600 to 1100 msec. The measurement time of 1 imaging slab took 15 to 20 minutes depending on the patient's heart rate. The coronary arteries were reconstructed from the 3-D data set using a multiplanar reconstruction (MPR) technique. According to previous coronary MRA studies, a significant stenosis with a luminal reduction of ≥50% was assumed if a marked signal reduction or signal loss of a vessel segment was visible. In CAG, 57 of 103 patients showed restenosis. In coronary MRA, 37 of 103 patients demonstrated restenosis. The sensitivity, specificity, positive and negative predictive values were 64.9%, 100%, 100% and 69.6%, respectively. Predictive accuracy was 79.6%. Three-dimensional coronary MRA is useful in a noninvasive diagnostic method to evaluate the coronary

  20. Coronary CT Angiography in the Quantitative Assessment of Coronary Plaques

    Directory of Open Access Journals (Sweden)

    Zhonghua Sun

    2014-01-01

    Full Text Available Coronary computed tomography angiography (CCTA has been recently evaluated for its ability to assess coronary plaque characteristics, including plaque composition. Identification of the relationship between plaque composition by CCTA and patient clinical presentations may provide insight into the pathophysiology of coronary artery plaque, thus assisting identification of vulnerable plaques which are associated with the development of acute coronary syndrome. CCTA-generated 3D visualizations allow evaluation of both coronary lesions and lumen changes, which are considered to enhance the diagnostic performance of CCTA. The purpose of this review is to discuss the recent developments that have occurred in the field of CCTA with regard to its diagnostic accuracy in the quantitative assessment of coronary plaques, with a focus on the characterization of plaque components and identification of vulnerable plaques.

  1. Design of a high-pressure circulating pump for viscous liquids.

    Science.gov (United States)

    Seifried, Bernhard; Temelli, Feral

    2009-07-01

    The design of a reciprocating dual action piston pump capable of circulating viscous fluids at pressures of up to 34 MPa (5000 psi) and temperatures up to 80 degrees C is described. The piston of this pump is driven by a pair of solenoids energized alternatively by a 12 V direct current power supply controlled by an electronic controller facilitating continuously adjustable flow rates. The body of this seal-less pump is constructed using off-the-shelf parts eliminating the need for custom made parts. Both the electronic controller and the pump can be assembled relatively easily. Pump performance has been evaluated at room temperature (22 degrees C) and atmospheric pressure using liquids with low and moderately high viscosities, such as ethanol and corn oil, respectively. At ambient conditions, the pump delivered continuous flow of ethanol and corn oil at a flow rate of up to 170 and 17 cm3/min, respectively. For pumping viscous fluids comparable to corn oil, an optimum reciprocation frequency was ascertained to maximize flow rate. For low viscosity liquids such as ethanol, a linear relationship between the flow rate and reciprocation frequency was determined up to the maximum reciprocation frequency of the pump. Since its fabrication, the pump has been used in our laboratory for circulating triglycerides in contact with supercritical carbon dioxide at pressures of up to 25 MPa (3600 psi) and temperatures up to 70 degrees C on a daily basis for a total of more than 1500 h of operation functioning trouble free.

  2. Detection of coronary calcification in ultrafast CT compared to coronary angiography

    International Nuclear Information System (INIS)

    Koesling, S.; Hoffmann, U.; Rother, T.; Lieberenz, S.; Heywang-Koebrunner, S.H.; Schulz, H.G.

    1994-01-01

    The angiographical findings of 24 patients with coronary artery disease were compared with qualitative and quantitative detection of coronary calcification by ultrafast CT. Doubts concerning the capabilities of the ultrafast CT for a screening of coronary artery disease arise when the results of one third false positive and fase negative findings are considered. Variations in the quantification of coronary calcification were too great to allow a realistic assessment of the degree of stenosis of the coronary arteries. (orig.) [de

  3. Making effective use of rod pumping systems in coalbed methane applications

    Energy Technology Data Exchange (ETDEWEB)

    Crivello, A. [eProduction Solutions Inc., Kingwood, TX (United States)

    2003-07-01

    The advantages of optimizing coalbed methane (CBM) operations are increased production, reduced expenses, improved efficiency, and better inventory. The author discussed the CBM production cycle and the possible artificial lift options, including electric submersible pump (ESP), plunger lift, primary coolant pump (PCP), and reciprocating rod lift. The presentation focused on the rod lift, as it represents a low to moderate capital expenditure, has good system efficiency, an excellent fluid volume range, an excellent salvage value, excellent familiarity with equipment, and has readily available parts and service. The major disadvantage of the rod lift is that the fixed operating range does not adapt to changing reservoir characteristics. A comparison between the rod pump controller and the variable speed drive was presented. The well can be operated at or near the pumped off condition with variable speed drives with rod pumping intelligence. The author provided a closer examination of the variable frequency drive and the vector flux drive. The presentation also included a discussion of prime movers, drive and inclinometer, gearbox loading, rod load limiter, and dynamometer cards. Three case studies were presented: CSW1, CSW2, and CSW3. It was concluded that wells must be kept pumping, and that a Flux Vector Drive should be used along with an NEMA B motor and properly sized pumping unit and pump. tabs., figs.

  4. Resonantly cladding-pumped Yb-free Er-doped LMA fiber laser with record high power and efficiency.

    Science.gov (United States)

    Zhang, Jun; Fromzel, Viktor; Dubinskii, Mark

    2011-03-14

    We report the results of our power scaling experiments with resonantly cladding-pumped Er-doped eye-safe large mode area (LMA) fiber laser. While using commercial off-the-shelf LMA fiber we achieved over 88 W of continuous-wave (CW) single transverse mode power at ~1590 nm while pumping at 1532.5 nm. Maximum observed optical-to-optical efficiency was 69%. This result presents, to the best of our knowledge, the highest power reported from resonantly-pumped Yb-free Er-doped LMA fiber laser, as well as the highest efficiency ever reported for any cladding-pumped Er-doped laser, either Yb-co-doped or Yb-free.

  5. Adsorption pump for helium pumping out

    International Nuclear Information System (INIS)

    Donde, A.L.; Semenenko, Yu.E.

    1981-01-01

    Adsorption pump with adsorbent cooling by liquid helium is described. Shuttered shield protecting adsorbent against radiation is cooled with evaporating helium passing along the coil positioned on the shield. The pump is also equipped with primed cylindrical shield, cooled with liquid nitrogen. The nitrogen shield has in the lower part the shuttered shield, on the pump casing there is a valve used for pump pre-burning, and valves for connection to recipient as well. Pumping- out rates are presented at different pressures and temperatures of adsorbent. The pumping-out rate according to air at absorbent cooling with liquid nitrogen constituted 5x10 -4 Pa-3000 l/s, at 2x10 -2 Pa-630 l/s. During the absorbent cooling with liquid hydrogen the pumping-out rate according to air was at 4x10 -4 Pa-580 l/s, at 2x10 -3 Pa-680 l/s, according to hydrogen - at 8x10 -5 Pa-2500 l/s, at 5x10 -3 Pa-4200 l/s. During adsorbent cooling with liquid helium the rate of pumping-out according to hydrogen at 3x10 5 Pa-2400% l/s, at 6x10 3 Pa-1200 l/s, and according to helium at 3.5x10 -5 Pa-2800 l/s, at 4x10 -3 Pa-1150 l/s. The limit vacuum is equal to 1x10 -7 Pa. The volume of the vessel with liquid helium is equal to 3.5 l. Helium consumption is 80 cm 3 /h. Consumption of liquid nitrogen from the shield is 400 cm 3 /h. The limit pressure in the pump is obtained after forevacuum pumping-out (adsorbent regeneration) at 300 K temperature. The pump is made of copper. The pump height together with primed tubes is 800 mm diameter-380 mm [ru

  6. A cryocondensation pump for the DIII-D Advanced Divertor Program

    International Nuclear Information System (INIS)

    Smith, J.P.; Baxi, C.; Reis, E.; Sevier, L.

    1992-03-01

    A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m 2 liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The whole pump is supported off the water-cooled vacuum vessel wall. Supports for the pump were designed to accommodate the thermal differences between the 4 K helium surface, the 77 K nitrogen shells, and the 300 K vacuum vessel supporting the pump and to provide a low heat leak structural support. Disruption loading on the pump was analyzed and a finite element structural analysis of the pump was completed. A testing program was completed to evaluate coating techniques to enhance heat transfer and emissivity of the various surfaces. Fabrication tests were performed to determine the best method of attaching the liquid nitrogen flow tubes to their shield surfaces and to determine the best alternative to fabricating the different shells of the pump. A prototype sector of the pump was built to verify fabrication and assembly techniques

  7. A Prospective Trial of Ayurveda for Coronary Heart Disease: A Pilot Study.

    Science.gov (United States)

    DuBroff, Robert; Lad, Vasant; Murray-Krezan, Cristina

    2015-01-01

    Coronary heart disease is the leading cause of death worldwide, and its incidence is rapidly accelerating in developing nations. Patients often search for therapies that are alternatives to traditional treatments, such as heart medicines, coronary bypass surgery, or coronary stenting. Ayurveda is an ancient, East Indian, holistic approach to health care, and its use has never been formally evaluated for patients with coronary heart disease. The study intended to examine the feasibility and effectiveness of comprehensive ayurvedic therapy-incorporating diet, meditation, breathing exercises, yoga, and herbs-for patients with established coronary heart disease. The study was a prospective, single-group, pilot study. The study took place at the University of New Mexico Cardiology Clinic and at the Ayurvedic Institute in Albuquerque, NM, USA. The participants were adults with a history of a prior heart attack, coronary bypass surgery, or a coronary intervention (ie, a coronary angioplasty and/or stent). All enrolled patients were evaluated by a single ayurvedic physician with >40 y of experience, and each received therapy consisting of a calorically unrestricted ayurvedic diet; instruction in yoga, meditation, and breathing; and use of ayurvedic herbs. The primary endpoint was arterial pulse wave velocity, a marker of arterial function and vascular health. Secondary endpoints included the following measurements: (1) body mass index (BMI); (2) blood pressure (BP) and amount of reduction in BP medications; and (3) levels of total cholesterol, low-density lipoprotein (LDL) cholesterol, high-density lipoprotein (HDL) cholesterol, and triglycerides. All parameters were measured at baseline and after 90 d of therapy. Twenty-two patients were enrolled in the study, and 19 patients completed it. The research team observed significant improvements in arterial pulse wave velocity (P = .015), and favorable reductions in BMI (P ayurveda on arterial function and multiple risk

  8. Commercial Submersible Mixing Pump For SRS Tank Waste Removal - 15223

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, Mike [Savannah River Remediation, LLC., Aiken, SC (United States); Herbert, James E. [Savannah River Remediation, LLC., Aiken, SC (United States); Scheele, Patrick W. [Savannah River Remediation, LLC., Aiken, SC (United States)

    2015-01-12

    product lubricated canned motor pumps designed to fit within available risers and have significant agitation capabilities to suspend waste solids. Waste removal and closure of two tanks has been accomplished with agitation provided by 3 SMPs installed within the tanks. In 2012, a team was assembled to investigate alternative solids removal technologies to support waste removal for closing tanks. The goal of the team was to find a more cost effective approach that could be used to replace the current mixing pump technology. This team was unable to identify an alternative technology outside of mixing pumps to support waste agitation and removal from SRS waste tanks. However, the team did identify a potentially lower cost mixing pump compared to the baseline SLPs and SMPs. Rather than using the traditional procurement using an engineering specification, the team proposed to seek commercially available submersible mixer pumps (CSMP) as alternatives to SLPs and SMPs. SLPs and SMPs have a high procurement cost and the actual cost of moving pumps between tanks has shown to be significantly higher than the original estimates that justified the reuse of SMPs and SLPs. The team recommended procurement of “off-the-shelf” industry pumps which may be available for significant savings, but at an increased risk of failure and reduced operating life in the waste tank. The goal of the CSMP program is to obtain mixing pumps that could mix from bulk waste removal through tank closure and then be abandoned in place as part of tank closure. This paper will present the development, progress and relative advantages of the CSMP.

  9. Validating the Beck Depression Inventory-II in Indonesia's general population and coronary heart disease patients

    NARCIS (Netherlands)

    Ginting, H.; Näring, G.W.B.; Veld, W.M. van der; Srisayekti, W.; Becker, E.S.

    2013-01-01

    This study assesses the validity and determines the cut-off point for the Beck Depression Inventory-II (the BDI-II) among Indonesians. The Indonesian version of the BDI-II (the Indo BDI-II) was administered to 720 healthy individuals from the general population, 215 Coronary Heart Disease (CHD)

  10. Angiographic characteristics of premature coronary artery disease in pakistan population; a prospective cross-sectional study

    International Nuclear Information System (INIS)

    Mustafa, B.; Rahman, H.U.

    2015-01-01

    Objective: To study the angiographic characteristics of premature coronary artery disease in our population. Methodology: From April 2014 to March 2015, coronary angiograms of 102 patients less than 40 years of age with a definitive diagnosis of ischemic heart disease were studied. Traditional risk factors of atherosclerosis were documented. Mode of presentation and symptoms were recorded along with angiographic findings of coronary artery disease severity, degree of coronary involvement, culprit vessel, lesion morphology, coronary dominance, coronary ectasia and left ventricular systolic function. Results: Mean age was 36.4 ± 4.1 years and 91% were male. Overall, left ventricular systolic function were fairly preserved (82%). 52% patients had single vessel CAD, 25% had double vessel while 19% had triple vessel coronary artery disease. Four patients had no luminal stenosis on coronary angiogram. LAD was the culprit vessel in 58.8%, RCA in 24.5% and left circumflex artery in 16.7% cases. More than 82% culprit lesions were severe or critical. 58% lesions were morphologically complex B2/C type while only 42% lesions were type A/B1. Coronary ectasia was seen in nearly 25% cases and all had ACS presentation. Right dominance was more common than left (57.8% vs 37.3%) while only 4.9% cases had dual posterior septal supply. Conclusion: Premature CAD in our population is acutely symptomatic, severe, complex (B2/C), single vessel disease. (author)

  11. Numerical study of pressure fluctuations in different guide vanes' opening angle in pump mode of a pump turbine

    International Nuclear Information System (INIS)

    Sun, Y K; Zuo, Z G; Liu, S H; Wu, Y L; Liu, J T

    2012-01-01

    A numerical model based on a pumped storage power station was built to develop the numerical simulation, to analyze the pressure fluctuations in a pump turbine in different guide vanes' opening angle. The different guide vanes' opening angles were simulated using the SST k-ω turbulence model and SIMPLEC Pressure-Velocity coupling scheme. The pressure sensor were placed in mainly three positions, they are: bottom ring between runner and the wicket gates, downstream and left side in the draft tube cone below the runner. All the peak to peak values of pressure fluctuation meet signal probability of 97%. The frequency is gained by Fast Fourier Transform. The pressure fluctuations in different positions of the model in pump condition were showed when the guide vanes' opening angels were different. The simulation results confirmed the results gained in model tests. The results show that pressure fluctuations in design opening angle were much lower than those in off design opening angle. The main source of pressure fluctuations between runner and guide vanes is rotor stator interaction. While a lower frequency is the main frequency of the pressure fluctuation in draft tube.

  12. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

    Science.gov (United States)

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M

    2011-09-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support

  13. Detection and severity of coronary disease: comparison between Framingham and calcium scores using multi-slice tomography

    International Nuclear Information System (INIS)

    Rodriguez Gomez, Maria Liliana; Montenegro, Edison; Ruiz, Angela Maria; Ardila, Jaime

    2011-01-01

    Introduction: multiple studies have shown that the coronary calcium index is an independent, more accurate predictor of future coronary events in relation to traditional risk factors. However, these studies have not been conducted in populations of developing countries like Colombia. Objective: to compare the strength of association between the Framingham index and the coronary calcium score in detecting the presence and severity of coronary disease as defined by 64-channel multi-slice angio-CT in order to provide additional information for decision-making in our asymptomatic coronary population. Methodology: we reviewed the written reports of coronary angiography scans performed in past 3 years. Based on this information, bivariate (calculation of Spearman rho correlation coefficients) and multivariate (logistic regression) analyses were performed. Results: the coronary calcium score showed a higher correlation with the presence and severity of coronary disease, Spearman Rho coefficient, compared with the Framingham index, Spearman's Rho coefficient of 0.30 (p<0.001). The moderate Framingham index (10-19%) shows no strength of association with significant and non-significant coronary artery disease, OR = 2, 51 CI 95% (0.7-8.9) and OR = 2.3 CI 95% (0.86-6.15), respectively. Patients with calcium values = 100 showed significant strength of association, OR = 182, 95% (17.4 -190.2), with significant coronary disease compared with high Framingham index values (=20%), OR = 18.6, CI 95% (1.75-198). Conclusions: the coronary calcium score has a higher correlation with the presence and severity of coronary disease when compared with the Framingham index. There is a low correlation between the index and Framingham coronary calcium.

  14. Inversion prepared coronary MR angiography: direct visualization of coronary blood flow

    International Nuclear Information System (INIS)

    Katoh, M.; Spuentrup, E.; Buecker, A.; Guenther, R.W.; Stuber, M.; Manning, W.J.; Botnar, R.M.

    2005-01-01

    Purpose: visualization of coronary blood flow by means of a slice-selective inversion pre-pulse in concert with bright-blood coronary MRA. Materials and methods: coronary magnetic resonance angiography (MRA) of the right coronary artery (RCA) was performed in eight healthy adult subjects on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Medical Systems, Best, NL) using a free-breathing navigator-gated and cardiac-triggered 3D steady-state free-precession (SSFP) sequence with radial k-space sampling. Imaging was performed with and without a slice-selective inversion pre-pulse, which was positioned along the main axis of the coronary artery but perpendicular to the imaging volume. Objective image quality parameters such as SNR, CNR, maximal visible vessel length, and vessel border definition were analyzed. Results: in contrast to conventional bright-blood 3D coronary MRA, the selective inversion pre-pulse provided a direct measure of coronary blood flow. In addition, CNR between the RCA and right ventricular blood pool was increased and the vessels had a tendency towards better delineation. Blood SNR and CNR between right coronary blood and epicardial fat were comparable in both sequences. (orig.)

  15. The impact of aortic manipulation on neurologic outcomes after coronary artery bypass surgery: a risk-adjusted study.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; Stamou, Sotiris C; Dullum, Mercedes K C; Hill, Peter C; Haile, Elizabeth; Boyce, Steven W; Bafi, Ammar S; Petro, Kathleen R; Corso, Paul J

    2004-11-01

    Cerebral embolization of atherosclerotic plaque debris caused by aortic manipulation during conventional coronary artery bypass grafting (CABG) is a major mechanism of postoperative cerebrovascular accidents (CVA). Off-pump CABG (OPCABG) reduces stroke rates by minimizing aortic manipulation. Consequently, the effect of different levels of aortic manipulation on neurologic outcomes after CABG surgery was examined. From January 1998 to June 2002, 7,272 patients underwent isolated CABG surgery through three levels of aortic manipulation: full plus tangential (side-biting) aortic clamp application (on-pump surgery; n = 4,269), only tangential aortic clamp application (OPCABG surgery; n = 2,527) or an "aortic no-touch" technique (OPCABG surgery; n = 476). A risk-adjusted logistic regression analysis was performed to establish the likelihood of postoperative stroke with each technique. Preoperative risk factors for stroke from the literature, and those found significant in a univariable model were used. A significant association for postoperative stroke correspondingly increasing with the extent of aortic manipulation was demonstrated by the univariable analysis (CVA incidence respectively increasing from 0.8% to 1.6% to a maximum of 2.2%, p < 0.01). In the logistic regression model, patients who had a full and a tangential aortic clamp applied were 1.8 times more likely to have a stroke versus those without any aortic manipulation (95% confidence interval: 1.15 to 2.74, p < 0.01) and 1.7 times more likely to develop a postoperative stroke than those with only a tangential aortic clamp applied (95% confidence interval: 1.11 to 2.48, p < 0.01). Aortic manipulation during CABG is a contributing mechanism for postoperative stroke. The incidence of postoperative stroke increases with increased levels of aortic manipulation.

  16. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 is pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump

  17. Cavitation performance improvement of high specific speed mixed-flow pump

    International Nuclear Information System (INIS)

    Chen, T; Sun, Y B; Wu, D Z; Wang, L Q

    2012-01-01

    Cavitation performance improvement of large hydraulic machinery such as pump and turbine has been a hot topic for decades. During the design process of the pumps, in order to minimize size, weight and cost centrifugal and mixed-flow pump impellers are required to operate at the highest possible rotational speed. The rotational speed is limited by the phenomenon of cavitation. The hydraulic model of high-speed mixed-flow pump with large flow rate and high pumping head, which was designed based on the traditional method, always involves poor cavitation performance. In this paper, on the basis of the same hydraulic design parameters, two hydraulic models of high-speed mixed-flow pump were designed by using different methods, in order to investigate the cavitation and hydraulic performance of the two models, the method of computational fluid dynamics (CFD) was adopted for internal flow simulation of the high specific speed mixed-flow pump. Based on the results of numerical simulation, the influences of impeller parameters and three-dimensional configuration on pressure distribution of the blades' suction surfaces were analyzed. The numerical simulation results shows a better pressure distribution and lower pressure drop around the leading edge of the improved model. The research results could provide references to the design and optimization of the anti-cavitation blade.

  18. Automated surveillance of reactor coolant pump performance

    International Nuclear Information System (INIS)

    Gross, K.C.; Singer, R.M.; Humenik, K.E.

    1992-01-01

    An artificial intelligence based expert system has been developed for continuous surveillance and diagnosis of centrifugal-type reactor coolant pump (RCP) performance and operability. The expert system continuously monitors digitized signals from a variety of physical variables (speed, vibration level, motor power, discharge pressure) associated with RCP performance for annunciation of the incipience or onset of off-normal operation. The system employs an extremely sensitive pattern-recognition technique, the sequential probability ratio test (SPRT) for rapid identification of pump operability degradation. The sequential statistical analysis of the signal noise has been shown to provide the theoretically shortest sampling time to detect disturbances and thus has the potential of providing incipient fault detection information to operators sufficiently early to avoid forced plant shutdowns. The sensitivity and response time of the expert system are analyzed in this paper using monte carlo simulation techniques

  19. Pumping mechanisms in sputter-ion pumps low pressure operation

    International Nuclear Information System (INIS)

    Welch, K.M.

    1991-01-01

    It is shown that significant H 2 pumping occurs in the walls of triode pumps. Also, H 2 is pumped in the anode cells of sputter-ion pumps. This pumping occurs in a manner similar to that by which the inert gases are pumped. That is, H 2 pumped in the walls of the anode cells by high energy neutral burial. Hydrogen in the pump walls and anodes limits the base pressure of the pump. 13 refs., 5 figs., 1 tab

  20. Interleukin-10 serum level in acute coronary syndrome patients

    Directory of Open Access Journals (Sweden)

    Idrus Alwi

    2009-09-01

    Full Text Available Aim To compare plasma IL-10 concentrations in patients with Acute Coronary Syndrome (ACS with those in Coronary Artery Disease (CAD.Methods ACS patients hospitalized in intensive coronary care unit (ICCU of Cipto Mangunkusumo Hospital/Faculty of Medicine University of Indonesia (CMH/FMUI, Persahabatan Hospital, MMC Hospital, and Medistra Hospital, Jakarta, between May 2005 and May 2006, were included in this study. The ambulatory CAD patients were taken as comparator. The serum IL-10 level was measured by immunoassay method, and compared by using Independent Student’s t-test. To investigate whether IL-10 serum level could predict ACS, the sensitivity and specificity of this parameter towards ACS in various IL-10 serum levels were calculated as well.Results In this observational study, as many as 146 subjects were analyzed, consisting of 84 ACS patients, and 62 coronary artery disease (CAD. The IL-10 level was higher in the group of ACS patients (7.37 pg/mL + 7.81, CI 95% 5.68-9.07 than that in CAD patients (1.59 pg/mL + 1.55, CI 95% 1.2-1.98. The optimal cut-off point for serum IL-10level is >1.95 pg/mL, with 79.76 % sensitivity and 77.42 % specificity.Conclusion The IL-10 level was higher in the ACS patients compared to that in CAD patients. Serum IL-10 measurement is a quite superior method to distinguish acute and stable condition, eventhough it is not as good as hsCRP for the same purpose. (Med J Indones 2009;18:165-9Key words: Interleukin-10, acute coronary syndrome

  1. Coronary Artery Anomalies in Animals

    Directory of Open Access Journals (Sweden)

    Brian A. Scansen

    2017-04-01

    Full Text Available Coronary artery anomalies represent a disease spectrum from incidental to life-threatening. Anomalies of coronary artery origin and course are well-recognized in human medicine, but have received limited attention in veterinary medicine. Coronary artery anomalies are best described in the dog, hamster, and cow though reports also exist in the horse and pig. The most well-known anomaly in veterinary medicine is anomalous coronary artery origin with a prepulmonary course in dogs, which limits treatment of pulmonary valve stenosis. A categorization scheme for coronary artery anomalies in animals is suggested, dividing these anomalies into those of major or minor clinical significance. A review of coronary artery development, anatomy, and reported anomalies in domesticated species is provided and four novel canine examples of anomalous coronary artery origin are described: an English bulldog with single left coronary ostium and a retroaortic right coronary artery; an English bulldog with single right coronary ostium and transseptal left coronary artery; an English bulldog with single right coronary ostium and absent left coronary artery with a prepulmonary paraconal interventricular branch and an interarterial circumflex branch; and a mixed-breed dog with tetralogy of Fallot and anomalous origin of all coronary branches from the brachiocephalic trunk. Coronary arterial fistulae are also described including a coronary cameral fistula in a llama cria and an English bulldog with coronary artery aneurysm and anomalous shunting vessels from the right coronary artery to the pulmonary trunk. These examples are provided with the intent to raise awareness and improve understanding of such defects.

  2. Utility of pulmonary venous flow diastolic deceleration time in an adult patient undergoing surgical closure of atrial septal defect and coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Dharmesh R Agrawal

    2013-01-01

    Full Text Available Acute left ventricular (LV failure has been reported after surgical closure of atrial septal defect (ASD in adult patients. We report acute LV failure in a 56 year old gentleman following coronary artery bypass grafting (CABG and surgical closure of ASD. Transesophageal echocardiography examination of the patient following closure of ASD and CABG showed a residual ASD and a shunt (Qp :Qs = 1.5. The residual ASD was closed after re-institution of cardiopulmonary bypass (CPB under cardioplegic cardiac arrest. However, the patient did not tolerate closure of the residual ASD. The CPB was re-established and under cardioplegic cardiac arrest residual ASD was reopened to create a fenestration. This time patient was weaned easily from CPB. Postoperatively, 16 hours after extubation, patient became hemodynamically unstable, the patient was electively put on ventilator and intra-aortic balloon pump. Later the patient was weaned off successfully from ventilator. Retrospective analysis of pulmonary venous flow diastolic deceleration time (PVDT D recorded during prebypass period measured 102 msec suggestive of high left atrial pressure which indicate possibility of LV failure after ASD closure.

  3. Myocardial Revascularization in Dyalitic Patients: In-Hospital Period Evaluation

    International Nuclear Information System (INIS)

    Miranda, Matheus; Hossne, Nelson Américo Jr.; Branco, João Nelson Rodrigues; Vargas, Guilherme Flora; Fonseca, José Honório de Almeida Palma da; Pestana, José Osmar Medina de Abreu; Juliano, Yara; Buffolo, Enio

    2014-01-01

    Coronary artery bypass grafting currently is the best treatment for dialytic patients with multivessel coronary disease, but hospital morbidity and mortality related to procedure is still high. Evaluate results and in-hospital outcomes of coronary artery bypass grafting in dialytic patients. Retrospective unicentric study including 50 consecutive and not selected dialytic patients, who underwent coronary artery bypass grafting in a tertiary university hospital from 2007 to 2012. High prevalence of cardiovascular risk factors was observed (100% hypertensive, 68% diabetic and 40% dyslipidemic). There was no intra-operative death and 60% of the procedures were performed off-pump. There were seven (14%) in-hospital deaths. Postoperative infection, previous heart failure, cardiopulmonary bypass, abnormal ventricular function and surgical re-exploration were associated with increased mortality. Coronary artery bypass grafting is feasible to dialytic patients although high in-hospital morbidity and mortality. It is necessary better understanding about metabolic aspects to plan adequate interventions

  4. Myocardial Revascularization in Dyalitic Patients: In-Hospital Period Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Matheus, E-mail: matheus10miranda@gmail.com; Hossne, Nelson Américo Jr.; Branco, João Nelson Rodrigues; Vargas, Guilherme Flora; Fonseca, José Honório de Almeida Palma da; Pestana, José Osmar Medina de Abreu [Escola Paulista de Medicina (EPM), Universidade Federal de São Paulo (Unifesp), São Paulo, SP (Brazil); Juliano, Yara [Universidade de Santo Amaro, São Paulo, SP (Brazil); Buffolo, Enio [Escola Paulista de Medicina (EPM), Universidade Federal de São Paulo (Unifesp), São Paulo, SP (Brazil)

    2014-02-15

    Coronary artery bypass grafting currently is the best treatment for dialytic patients with multivessel coronary disease, but hospital morbidity and mortality related to procedure is still high. Evaluate results and in-hospital outcomes of coronary artery bypass grafting in dialytic patients. Retrospective unicentric study including 50 consecutive and not selected dialytic patients, who underwent coronary artery bypass grafting in a tertiary university hospital from 2007 to 2012. High prevalence of cardiovascular risk factors was observed (100% hypertensive, 68% diabetic and 40% dyslipidemic). There was no intra-operative death and 60% of the procedures were performed off-pump. There were seven (14%) in-hospital deaths. Postoperative infection, previous heart failure, cardiopulmonary bypass, abnormal ventricular function and surgical re-exploration were associated with increased mortality. Coronary artery bypass grafting is feasible to dialytic patients although high in-hospital morbidity and mortality. It is necessary better understanding about metabolic aspects to plan adequate interventions.

  5. On the Profitability of Variable Speed Pump-Storage-Power in Frequency Restoration Reserve

    Science.gov (United States)

    Filipe, Jorge; Bessa, Ricardo; Moreira, Carlos; Silva, Bernardo

    2017-04-01

    The increase penetration of renewable energy sources (RES) into the European power system has introduced a significant amount of variability and uncertainty in the generation profiles raising the needs for ancillary services as well as other tools like demand response, improved generation forecasting techniques and changes to the market design. While RES is able to replace energy produced by the traditional centralized generation, it cannot displace its capacity in terms of ancillary services provided. Therefore, centralized generation capacity must be retained to perform this function leading to over-capacity issues and underutilisation of the assets. Large-scale reversible hydro power plants represent the majority of the storage solution installed in the power system. This technology comes with high investments costs, hence the constant search for methods to increase and diversify the sources of revenue. Traditional fixed speed pump storage units typically operate in the day-ahead market to perform price arbitrage and, in some specific cases, provide downward replacement reserve (RR). Variable speed pump storage can not only participate in RR but also contribute to FRR, given their ability to control its operating point in pumping mode. This work does an extended analysis of a complete bidding strategy for Pumped Storage Power, enhancing the economic advantages of variable speed pump units in comparison with fixed ones.

  6. Comprehensive experimental and numerical analysis of instability phenomena in pump turbines

    International Nuclear Information System (INIS)

    Gentner, Ch; Sallaberger, M; Widmer, Ch; Bobach, B-J; Jaberg, H; Schiffer, J; Senn, F; Guggenberger, M

    2014-01-01

    The changes in the electricity market have led to changed requirements for the operation of pump turbines. Utilities need to change fast and frequently between pumping and generating modes and increasingly want to operate at off-design conditions for extended periods. Operation of the units in instable areas of the machine characteristic is not acceptable and may lead to self-excited vibration of the hydraulic system. In turbine operation of pump turbines unstable behaviour can occur at low load off-design operation close to runaway conditions (S-shape of the turbine characteristic). This type of instability may impede the synchronization of the machine in turbine mode and thus increase start-up and switch over times. A pronounced S-shaped instability can also lead to significant drop of discharge in the event of load rejection. Low pressure on the suction side and in the tail-race tunnel could cause dangerous separation of the water column. Understanding the flow features that lead to the instable behaviour of pump turbines is a prerequisite to the design of machines that can fulfil the growing requirements relating to operational flexibility. Flow simulation in these instability zones is demanding due to the complex and highly unsteady flow patterns. Only unsteady simulation methods are able to reproduce the governing physical effects in these operating regions. ANDRITZ HYDRO has been investigating the stability behaviour of pump turbines in turbine operation in cooperation with several universities using simulation and measurements. In order to validate the results of flow simulation of unstable operating points, the Graz University of Technology (Austria) performed detailed experimental investigations. Within the scope of a long term research project, the operating characteristics of several pump turbine runners have been measured and flow patterns in the pump turbine at speed no load and runaway have been examined by 2D Laser particle image velocimetry (PIV

  7. System transient response to loss of off-site power

    International Nuclear Information System (INIS)

    Sozer, A.

    1990-01-01

    A simultaneous trip of the reactor, main circulation pumps, secondary coolant pumps, and pressurizer pump due to loss of off-site power at the High Flux Isotope Reactor (HFIR) located at the Oak Ridge National Laboratory (ORNL) has been analyzed to estimate available safety margin. A computer model based on the Modular Modeling System code has been used to calculate the transient response of the system. The reactor depressurizes from 482.7 psia down to about 23 psia in about 50 seconds and remains stable thereafter. Available safety margin has been estimated in terms of the incipient boiling heat flux ratio. It is a conservative estimate due to assumed less than available primary and secondary flows and higher than normal depressurization rate. The ratio indicates no incipient boiling conditions at the hot spot. No potential damage to the fuel is likely to occur during this transient. 2 refs., 6 figs

  8. Solar photovoltaic water pumping for remote locations

    International Nuclear Information System (INIS)

    Meah, Kala; Fletcher, Steven; Ula, Sadrul

    2008-01-01

    Many parts of the world as well as the western US are rural in nature and consequently do not have electrical distribution lines in many parts of villages, farms, and ranches. Distribution line extension costs can run from USD 10,000 to USD 16,000/km, thereby making availability of electricity to small water pumping projects economically unattractive. But, ground water and sunlight are available, which make solar photovoltaic (SPV) powered water pumping more cost effective in these areas' small scale applications. Many western states including Wyoming are passing through the sixth year of drought with the consequent shortages of water for many applications. The Wyoming State Climatologist is predicting a possible 5-10 years of drought. Drought impacts the surface water right away, while it takes much longer to impact the underground aquifers. To mitigate the effect on the livestock and wildlife, Wyoming Governor Dave Freudenthal initiated a solar water pumping initiative in cooperation with the University of Wyoming, County Conservation Districts, Rural Electric Cooperatives, and ranching organizations. Solar water pumping has several advantages over traditional systems; for example, diesel or propane engines require not only expensive fuels, they also create noise and air pollution in many remote pristine areas. Solar systems are environment friendly, low maintenance, and have no fuel cost. In this paper the design, installation, site selection, and performance monitoring of the solar system for small-scale remote water pumping will be presented. This paper also presents technical, environmental, and economic benefits of the SPV water pumping system compared to stand alone generator and electric utility. (author)

  9. Relationship between chronic obstructive pulmonary disease and subclinical coronary artery disease in long-term smokers

    DEFF Research Database (Denmark)

    Rasmussen, Thomas; Køber, Lars; Pedersen, Jesper Holst

    2013-01-01

    Cardiovascular conditions are reported to be the most frequent cause of death in patients with chronic obstructive pulmonary disease (COPD). However, it remains unsettled whether severity of COPD per se is associated with coronary artery disease (CAD) independent of traditional cardiovascular risk...... factors. The aim of this study was to examine the relationship between the presence and severity of COPD and the amount of coronary artery calcium deposit, an indicator of CAD and cardiac risk, in a large population of current and former long-term smokers....

  10. Diagnosing coronary artery disease after a positive coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nissen, L; Winther, S; Westra, J

    2018-01-01

    Aims: Perfusion scans after coronary computed tomography angiography (CCTA) in patients with suspected coronary artery disease (CAD) may reduce unnecessary invasive coronary angiographies (ICAs). However, the diagnostic accuracy of perfusion scans after primary CCTA is unknown. The aim...

  11. Non-obstructive coronary artery disease assessed by coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Nielsen, L.; Bøtker, H. E.; Sorensen, H.

    2015-01-01

    Introduction: Coronary CT angiography (CTA) detects non-obstructive coronary artery disease (CAD) that may not be recognized by functional testing, but the prognostic impact is not well understood. This study aimed to compare the risk of myocardial infarction (MI) and all-cause mortality...... in patients without or with non-obstructive and obstructive CAD assessed by coronary CTA. Methods: Consecutive patients without known coronary artery disease (CAD) and with chest pain who underwent coronary CTA (>64-detector row) between January 2007 and December 2012 in the 10 centers participating...... in the Western Denmark Cardiac Computed Tomography Registry were included. The endpoints were 3-year MI or all-cause mortality. The coronary CTA result was defined as normal (0% luminal stenosis), non-obstructive CAD (1%-49% luminal stenosis) or obstructive CAD (>50% luminal stenosis; 1-vessel, 2-vessel, or 3...

  12. Coronary hemodynamics in vasospastic angina

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Kubota, Shinobu; Serizawa, Takashi; Nakase, Emiko; Kawai, Ichiro; Saito, Takayuki

    1991-01-01

    To evaluate the coronary circulation and myocardial perfusion dynamics, we performed left coronary digital subtraction angiography (DSA) in 35 patients with vasospastic angina. The left coronary circulation time (CCT) measured from the proximal left coronary artery to the coronary sinus was 5.77±0.86 sec, and the left epicardial conducting artery transmission time (CAT) measured from the proximal left coronary artery to the apical area was 2.65±0.82 sec in normal controls. The CCT and CAT were significantly prolonged in patients with vasospastic angina, indicating that the coronary peripheral vascular resistance is probably greater after the cessation of nitrates and Ca ++ -antagonists. After the intracoronary injection of ergonovine malate, the CCT was slightly shortened, but the apical T 1/2 was significantly prolonged in patients with vasospastic angina. This suggested that coronary vasospasm is present not only in the epicardial arteries but also in coronary arteries with peripheral resistance. These phenomena were not observed in normal controls. We performed left coronary DSA after conventional left coronary cineangiography. When the CCT exceeded 6.7 sec, we considered that the coronary circulation was significantly impaired. We concluded that the coronary DSA is very useful for evaluating abnormal coronary circulation in patients with vasospastic angina during myocardial perfusion. (author)

  13. Education and coronary heart disease: mendelian randomisation study.

    Science.gov (United States)

    Tillmann, Taavi; Vaucher, Julien; Okbay, Aysu; Pikhart, Hynek; Peasey, Anne; Kubinova, Ruzena; Pajak, Andrzej; Tamosiunas, Abdonas; Malyutina, Sofia; Hartwig, Fernando Pires; Fischer, Krista; Veronesi, Giovanni; Palmer, Tom; Bowden, Jack; Davey Smith, George; Bobak, Martin; Holmes, Michael V

    2017-08-30

    Objective  To determine whether educational attainment is a causal risk factor in the development of coronary heart disease. Design  Mendelian randomisation study, using genetic data as proxies for education to minimise confounding. Setting  The main analysis used genetic data from two large consortia (CARDIoGRAMplusC4D and SSGAC), comprising 112 studies from predominantly high income countries. Findings from mendelian randomisation analyses were then compared against results from traditional observational studies (164 170 participants). Finally, genetic data from six additional consortia were analysed to investigate whether longer education can causally alter the common cardiovascular risk factors. Participants  The main analysis was of 543 733 men and women (from CARDIoGRAMplusC4D and SSGAC), predominantly of European origin. Exposure  A one standard deviation increase in the genetic predisposition towards higher education (3.6 years of additional schooling), measured by 162 genetic variants that have been previously associated with education. Main outcome measure  Combined fatal and non-fatal coronary heart disease (63 746 events in CARDIoGRAMplusC4D). Results  Genetic predisposition towards 3.6 years of additional education was associated with a one third lower risk of coronary heart disease (odds ratio 0.67, 95% confidence interval 0.59 to 0.77; P=3×10 -8 ). This was comparable to findings from traditional observational studies (prevalence odds ratio 0.73, 0.68 to 0.78; incidence odds ratio 0.80, 0.76 to 0.83). Sensitivity analyses were consistent with a causal interpretation in which major bias from genetic pleiotropy was unlikely, although this remains an untestable possibility. Genetic predisposition towards longer education was additionally associated with less smoking, lower body mass index, and a favourable blood lipid profile. Conclusions  This mendelian randomisation study found support for the hypothesis that low education is a causal risk

  14. Design and development of a new pulsating cardiac coronary phantom for ECG-gated CT and its experimental characteristics

    International Nuclear Information System (INIS)

    Shen, Yun; Sato, Munekuni; Kimura, Fumiko; Jinzaki, Masahiro; Kuribayashi, Sachio; Horiguchi, Jun; Ito, Katsuhide

    2005-01-01

    The optimal pulsating cardiac phantom is an important tool for the evaluation of cardiac images and cardiac applications on electrocardiogram (ECG)-gated multidetector-row CT (MDCT). The purpose of this study was to demonstrate the design and fabrication of the pulsating cardiac coronary phantom. The newly developed pulsating cardiac coronary phantom has the following five key advantages: a driver component that uses only one servomotor to move the phantom in three dimensions (X, Y, and Z directions) with 16 presets of different heart types (heartbeat: 0-120 bpm; ejection fraction: 0-90%); versatile pumping and filling phases to simulate a real heart in a cardiac cycle can be incorporated into the driver sequence including shift of patient heartbeat or irregular pulse (maximum: 200 different heart waves in one scan); a cardiac coronary component constituted of an acrylic/silicon/rubber tube (2-6 mm inner diameter) with stent/in-stent restenosis/stenosis/soft plaque/calcification parts and maximum 16 coronary arteries that can be attached to the phantom in the same scan; the complete phantom can be submerged in a tank to simulate the heart and its surrounding tissues; ECG gating can be from interior trigger and exterior trigger. It has been confirmed that the developed pulsating cardiac phantom is very useful to quantitatively assess imaging of the heart and coronary arteries during phantom experiments. (author)

  15. Infrared-x-ray pump-probe spectroscopy of the NO molecule

    International Nuclear Information System (INIS)

    Guimaraes, F.F.; Felicissimo, V.C.; Kimberg, V.; Gel'mukhanov, F.; Aagren, H.; Cesar, A.

    2005-01-01

    Two color infrared-x-ray pump-probe spectroscopy of the NO molecule is studied theoretically and numerically in order to obtain a deeper insight of the underlying physics and of the potential of this suggested technology. From the theoretical investigation a number of conclusions could be drawn: It is found that the phase of the infrared field strongly influences the trajectory of the nuclear wave packet, and hence, the x-ray spectrum. The trajectory experiences fast oscillations with the vibrational frequency with a modulation due to the anharmonicity of the potential. The dependences of the x-ray spectra on the delay time, the duration, and the shape of the pulses are studied in detail. It is shown that the x-ray spectrum keep memory about the infrared phase after the pump field left the system. This memory effect is sensitive to the time of switching-off the pump field and the Rabi frequency. The phase effect takes maximum value when the duration of the x-ray pulse is one-fourth of the infrared field period, and can be enhanced by a proper control of the duration and intensity of the pump pulse. The manifestation of the phase is different for oriented and disordered molecules and depends strongly on the intensity of the pump radiation

  16. Infrared x-ray pump-probe spectroscopy of the NO molecule

    Science.gov (United States)

    Guimarães, F. F.; Kimberg, V.; Felicíssimo, V. C.; Gel'Mukhanov, F.; Cesar, A.; Ågren, H.

    2005-07-01

    Two color infrared x-ray pump-probe spectroscopy of the NO molecule is studied theoretically and numerically in order to obtain a deeper insight of the underlying physics and of the potential of this suggested technology. From the theoretical investigation a number of conclusions could be drawn: It is found that the phase of the infrared field strongly influences the trajectory of the nuclear wave packet, and hence, the x-ray spectrum. The trajectory experiences fast oscillations with the vibrational frequency with a modulation due to the anharmonicity of the potential. The dependences of the x-ray spectra on the delay time, the duration, and the shape of the pulses are studied in detail. It is shown that the x-ray spectrum keep memory about the infrared phase after the pump field left the system. This memory effect is sensitive to the time of switching-off the pump field and the Rabi frequency. The phase effect takes maximum value when the duration of the x-ray pulse is one-fourth of the infrared field period, and can be enhanced by a proper control of the duration and intensity of the pump pulse. The manifestation of the phase is different for oriented and disordered molecules and depends strongly on the intensity of the pump radiation.

  17. Noninvasive imaging of coronary arteries: current and future role of multidetector row computer tomography

    International Nuclear Information System (INIS)

    Nedevska, M.; Stoinova, V.

    2006-01-01

    Full text: This review will present the current and future role of cardiac computer tomography (CCT), and particular multidetector CCT, for imaging of atherosclerotic pathologic changes of the coronary arteries. Atherosclerosis and its cardio-vascular complications represent one of the major issues of public health in industrial countries. Different imaging modalities, including invasive coronarography, have been aimed to the diagnosis of the disease, when it provokes symptomatic decrease of the blood flow. In spite of development of surgical and percutaneous methods for coronary revascularization, coronary artery disease remains the major cause of death in North America and Europe. This demonstrates the need of novel, complementary diagnostic strategies, aimed to identify asymptomatic stages as the basis of pharmacological interventions. Noninvasive coronary angiography with multidetector CT allows both assessment of luminal stenosis and subclinical disease of arterial wall. Large trails are missing now to understand and present what will be the role of this technology in the comprehensive assessment of patients, suspected of having CAD. Based on experience and current potentials we will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development

  18. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    Full Text Available Abstract Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE, it is still used as an adjunct to coronary artery bypass grafting (CABG. This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA, angina pectoris (CCS and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG with adjunctive coronary endarterectomy (CE in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient. In 98% left internal thoracic artery (LITA was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA (n = 55, on left anterior descending artery (LAD (n = 52 and circumflex artery (RCX (n = 7. Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%. Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5. During follow-up (24.5 ± 13.4 months, which is 96% complete (4 patients were lost caused by unknown address 8 patients died (cardiac

  19. A successful retrieval of stripped outer coating of J-tip diagnostic guidewire from the left popliteal artery during elective coronary angiography

    Directory of Open Access Journals (Sweden)

    Damjanović Miodrag

    2014-01-01

    Full Text Available Introduction. Entrapment and fracture of diagnostic or therapeutic devices within the coronary circulatory system are a rare, but increasing problem. Case report. A 70-yearold man was admitted in our clinic for coronary angiography before the planned aortic valve replacement. An arterial sheath was inserted in the right common femoral artery. After introducing a J-tip diagnostic coronary guidewire into the aorta and advancing a left Judkins diagnostic catheter over it, suddenly occured peeling off of the wire´s hydrophilic coating at the aortic arch level. Very soon, this outer coating of guidewire carried by the blood stream was entered into the left femoral artery, then into the left popliteal artery. This stripped part of guidewire was successfully caught and extracted out by using a goose-neck snare catheter. Conclusion. A sudden stripping of outer coating of a J-tip diagnostic hydrophilic coronary guidewire during coronary angiography is possible to manage quickly and successfully by the use of a simple cathether.

  20. The development of a cavitation free sodium pump for the breeder reactor

    International Nuclear Information System (INIS)

    Baladi, J.Y.; Nyilas, C.P.

    1986-01-01

    The sodium pumps for a liquid metal fast breeder reactor must be designed for exceptionally high reliability and long life. The principal adverse factor which tends to limit the primary pump life is cavitation which becomes potentially severe under off-design flow conditions caused by the requirement of two loop operations which resulted in a large operating flow range. This problem prompted an extensive study which included experimental investigations of scaled down and full size pumps. The investigations involved visual observations, acoustic signature recordings, and physical characteristic measurements of the model and full size impellers. The blade configuration of the model was modified several times. This paper describes the test facilities erected for this study, discusses the experimental techniques employed, and presents a sample of the experimental results

  1. [Comparison of 64 MDCT coronary CTA and coronary angiography in the detection of coronary artery stenosis in low risk patients with stable angina and acute coronary syndrome].

    Science.gov (United States)

    Cazalas, G; Sarran, A; Amabile, N; Chaumoitre, K; Marciano-Chagnaud, S; Jacquier, A; Paganelli, F; Panuel, M

    2009-09-01

    To determine the accuracy of 64 MDCT coronary CTA (CCTA) compared to coronary angiography in low risk patients with stable angina and acute coronary syndrome and determine the number of significant coronary artery stenoses ( 50%) in these patients. Materials and methods. Fifty-five patients underwent CCTA using a 32 MDCT unit with z flying focus allowing the acquisition of 64 slices of 0.6 mm thickness as well as coronary angiography (gold standard). Nine patients were excluded due to prior coronary artery bypass surgery (n=4), insufficient breath hold (n=3), calcium scoring>1000 (n=1) and delay between both examinations over 4 months (n=1). Forty-six patients: 27 males and 19 females were included. CCTA results were compared to coronary angiography per segment and artery with threshold detection of stenoses 50%. The degree of correlation between both examinations was performed using a regression analysis with a Pearson correlation coefficient<0.05 considered significant. The overall accuracy of CCTA was 90%; limitations related to the presence of calcifications, motion artifacts or insufficient vessel opacification. The correlation for all analyzed segments was 96.4%. Thirty-eight of 50 significant stenoses seen on coronary angiography were correctly detected on CCTA. Sensitivity, specificity, PPVC and NPV for detection of stenoses 50% were 76%, 98.3%, 80.3% and 97.7% respectively. Evaluation per segment had a NPV of 96.8% (interventricular and diagonal segments) to 100% (main trunk). Our results for specificity and NPV are similar to reports from the literature. This suggests that CCTA in this clinical setting may replace coronary angiography.

  2. Morphological study on coronary ostial and clinicoangiographic analysis of isolated coronary ostial stenosis

    International Nuclear Information System (INIS)

    Kanoh, Tatsuji

    2007-01-01

    A morphological study of coronary ostia was performed in 70 autopsied human hearts, with particular attention being focused on the funnel-shaped structure, aging changes, and relation to atherosclerosis. The following results were obtained: The ostium is particularly well-defined and forms a funnel-shaped structure. The structure is predominantly a double circular shape on the right and comet-shaped on the left. The funnel-shaped structure of coronary ostia is characterized by a longitudinal smooth muscle arrangement in the inner layer and circular one in the outer layer. Including overhang formation, coronary sclerosis of the ostium appears mainly on the upper margin of the funnel-shaped structure of the right ostium and at the upper right margin of the left. In ischemic heart disease, along with changes in coronary arteries themselves, changes in the ostia of these arteries should be paid close attention. Ostial stenosis of the coronary artery in the absence of distal vessel obstructions, isolated ostial stenosis, is a rare form of coronary artery disease. In a previous review of the international literature, the incidence of coronary ostial stenosis varied between 0.13% and 2.7%. Among 7,500 patients undergoing selective coronary cineangiography at Juntendo University Hospital and Juntendo Urayasu Hospital from 1975 to 1990, five women (0.07%) were diagnosed as having ''isolated coronary ostial stenosis'', of which the cause is unknown. Atherosclerosis, particularly early premature atherome, congenital coronary anomaly, fibro-muscular dysplasia, Takayasu's aortitis, humoral factors, spasm, and iatrogenic events have been considered as its causes. In contrast to usual atherosclerotic coronary artery disease, patients with isolated coronary ostial stenosis of unknown etiology were characterized as being middle-aged, premenopausal, slender females having few coronary risk factors, experiencing severe angina pector is with marked ischemic electrocardiogram changes

  3. Factors influencing delay time and coronary arterial density during coronary angiography with DSCT.

    Science.gov (United States)

    Tang, Lijun; Zhu, Xiaomei; Xu, Yi; Yu, Tongfu; Xu, Hai; Tang, Jinhua; Dogra, Vikram; Wang, Dehang

    2011-02-01

    CT angiography (CTA) plays an important role in diagnosing coronary arterial disease. Delay time and density of the coronary arteries related with patient-specific factors are essential for getting an optimal CTA image. To investigate various factors influencing delay time and coronary arterial density during coronary CTA with dual source CT. One hundred and sixteen consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Factors including gender, age, height, weight, transversal cardiac diameter (TCD), transversal thoracic diameter (TTD), heart rate (HR), body surface area (BSA = [weight × height/3600](1/2)) and cardiothoracic ratio (CTR = TCD/TTD) were recorded, measured and calculated before administration of contrast media during coronary CT angiography. Delay time was determined as duration from the beginning of the injection to the density in the descending aorta at the level of right main pulmonary artery reaching a threshold of 100 HU. Coronary arterial density was measured at the mid portion of the right coronary artery. Regression analysis and stepwise regression analysis were used to investigate the influence of these factors on delay time and coronary arterial density. Delay time decreased with an increasing HR and it was shorter in women than men. Delay time increased with an increasing TCD. Delay time could be predicted by the formula: DT = 16.651-0.110 × HR + 1.902 × gender + 0.394 × TCD (where DT is abbreviation for delay time, gender is 0 for women and 1 for men). Coronary arterial density decreased with an increasing HR and weight. Coronary arterial density could be predicted by the formula: CAD = 923.42-4.099 × HR-3.293 × weight (CAD = coronary arterial density). There was no relationship between the other factors mentioned above and delay time or coronary arterial density. Delay time is influenced by HR, gender and TCD. Coronary arterial density also changes with HR and weight. So HR, gender, TCD and

  4. Reversible pumped hydro - benefits and challenges

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Torbjoern K.; Walseth, Eve C.

    2010-07-01

    Full text: The Norwegian hydro power system is dominated with high head turbines, Pelton and Francis with high capacity in the reservoirs. Originally they were built for secure energy supply. In the system there are also reversible pump turbine (RPT) plants where in times with spare energy, made it possible to pump water from the lower reservoir to the higher. Again the idea was to secure energy supply, which meant pumping in early autumn to fill the reservoirs for winter. In the recent years, a more active use of the RPT plants has been actualized. The free market made price difference between night and day interesting, hence a more frequent pumping was desirable. In the coming years, new-renewable energy sources will utterly enhance a more active use of the RPT plants. More active use of the RPT plants means more frequent starts and stops, both in pumping and in turbine mode. There are a lot of challenges in adopting a new strategy for operating the machinery. More effective start equipment is required. The machinery will be exposed to more frequent dynamic loads; the turbines will be run at part- and full load. The existing RPT plants are connected to huge reservoirs. That means the RPTs are not only for short sighted power regulations, as many RPT-plants in Europe, but are also capable for a substantial energy production. In Norway, the nature is very suitable for RPT plants, both in connection with existing power plants, were reservoirs and conduits are already established, and standing alone with a minimum of energy production. RPTs are, as a design, a compromise between effective generating and stable as well as effective pumping. Stable pumping often results in very steep flow-speed characteristics when operating as a turbine. When dealing with hydraulic transients these characteristics cause a higher change in flow and torque leading to instability during start-up and possible off-design operation point. The instability slows down the synchronization

  5. Centrifugal pumps

    CERN Document Server

    Anderson, HH

    1981-01-01

    Centrifugal Pumps describes the whole range of the centrifugal pump (mixed flow and axial flow pumps are dealt with more briefly), with emphasis on the development of the boiler feed pump. Organized into 46 chapters, this book discusses the general hydrodynamic principles, performance, dimensions, type number, flow, and efficiency of centrifugal pumps. This text also explains the pumps performance; entry conditions and cavitation; speed and dimensions for a given duty; and losses. Some chapters further describe centrifugal pump mechanical design, installation, monitoring, and maintenance. The

  6. High-speed off-axis holographic cinematography with a copper-vapor-pumped dye laser.

    Science.gov (United States)

    Lauterborn, W; Judt, A; Schmitz, E

    1993-01-01

    A series of coherent light pulses is generated by pumping a dye laser with the pulsed output of a copper-vapor laser at rates of as much as 20 kHz. Holograms are recorded at this pulse rate on a rotating holographic plate. This technique of high-speed holographic cinematography is demonstrated by viewing the bubble filaments that appear in water under the action of a sound field of high intensity.

  7. Myocardial flow reserve is influenced by both coronary artery stenosis severity and coronary risk factors in patients with suspected coronary artery disease

    International Nuclear Information System (INIS)

    Tsukamoto, Takahiro; Naya, Masanao; Tsutsui, Hiroyuki; Morita, Koichi; Katoh, Chietsugu; Inubushi, Masayuki; Kuge, Yuji; Tamaki, Nagara

    2006-01-01

    Myocardial flow reserve (MFR) measurement has an important role in assessing the functional severity of coronary artery stenosis. However, a discrepancy between the anatomical severity of coronary artery stenosis and MFR is often observed. Such a discrepancy may be explained by coronary risk factors. In this study, we aimed to investigate the influence of coronary artery stenosis severity and risk factors on MFR. Seventy-four patients suspected to have coronary artery disease and seven age-matched healthy volunteers were enrolled. Myocardial blood flow (MBF) and MFR were measured using 15 O-labelled water PET. Regional MFR was calculated in regions with significant coronary artery stenosis (stenotic regions) and in regions without significant stenosis (remote regions). The contributions of coronary artery stenosis severity and coronary risk factors were assessed using univariate and multivariate analyses. In stenotic regions, MFR correlated inversely with coronary artery stenosis severity (r=-0.50, p<0.01). Univariate analysis did not show any significant difference in MFR between the patients with and the patients without each risk factor. In remote regions, however, MFR was significantly decreased in the diabetes and smoking groups (each p<0.05). By multivariate analysis, diabetes and smoking were independent predictors of MFR (each p<0.05). In the group with more than one risk factor, MFR was significantly lower (2.78±0.79) than in the other group (3.40±1.22, p<0.05). MFR is influenced not only by coronary stenosis severity but also by coronary risk factors. In particular, the influence of risk factors should be considered in regions without severe coronary stenosis. (orig.)

  8. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  9. LMFBR with booster pump in pumping loop

    International Nuclear Information System (INIS)

    Rubinstein, H.J.

    1975-01-01

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation

  10. Nuclear radiation detected optical pumping of neutron deficient Hg isotopes

    International Nuclear Information System (INIS)

    Bonn, J.

    1975-01-01

    The extension of the Nuclear Radiation Detected Optical Pumping method to mass-separated samples of isotopes far off stability is presented for a series of light Hg isotopes produced at the ISOLDE facility at CERN. The isotope under investigation is transferred by an automatic transfer system into the optical pumping apparatus. Zeeman scanning of an isotopically pure Hg spectral lamp is used to reach energetic coincidence with the hyperfine structure components of the 6s 2 1 S 0 -6s6p 3 P 1 (lambda = 2537 A) resonance line of the investigated isotope and the Hg lamp. The orientation build up by optical pumping is monitored via the asymmetry or anisotropy of the nuclear radiation. Nuclear spins, magnetic moments, electric quadrupole moments and isotopic shift are obtained for 181 Hg- 191 Hg using the β-asymmetry as detector. The extension of the method using the γ-anisotropy is discussed and measurements on 193 Hg are presented. (orig./HK)

  11. Experimental and numerical investigation of centrifugal pumps with asymmetric inflow conditions

    Science.gov (United States)

    Mittag, Sten; Gabi, Martin

    2015-11-01

    Most of the times pumps operate off best point states. Reasons are changes of operating conditions, modifications, pollution and wearout or erosion. As consequences non-rotational symmetric flows, transient operational conditions, increased risk of cavitation, decrease of efficiency and unpredictable wearout can appear. Especially construction components of centrifugal pumps, in particular intake elbows, contribute to this matter. Intake elbows causes additional losses and secondary flows, hence non-rotational velocity distributions as intake profile to the centrifugal pump. As a result the impeller vanes experience permanent changes of the intake flow angle and with it transient flow conditions in the blade channels. This paper presents the first results of a project, experimentally and numerically investigating the consequences of non-rotational inflow to leading edge flow conditions of a centrifugal pump. Therefore two pumpintake- elbow systems are compared, by only altering the intake elbow geometry: a common single bended 90° elbow and a numerically optimized elbow (improved regarding rotational symmetric inflow conditions and friction coefficient). The experiments are carried out, using time resolved stereoscopic PIV on a full acrylic pump with refractions index matched (RIM) working fluid. This allows transient investigations of the flow field simultaneously for all blade leading edges. Additional CFD results are validated and used to further support the investigation i.e. for comparing an analog pump system with ideal inflow conditions.

  12. Coronary Anomaly and Coronary Artery Fistula as Cause of Angina Pectoris with Literature Review

    Directory of Open Access Journals (Sweden)

    Jayanth Koneru

    2011-01-01

    Full Text Available Coronary artery fistulas are rare anomalies of the coronary arteries that may sometimes cause symptoms by shunting blood flow away from the myocardial capillary network. We report the case of a 46-year old lady which shows the right coronary cusp giving rise to left main coronary artery called anomalous origin of a coronary artery (AOCA, and also a fistula between the left coronary artery and pulmonary artery. We describe our diagnostic approach and review the literature on the epidemiology, pathophysiology, the diagnostic modalities, and treatment options.

  13. Role of coronary physiology in the contemporary management of coronary artery disease

    Science.gov (United States)

    Ruparelia, Neil; Kharbanda, Rajesh K

    2015-01-01

    Coronary artery disease (CAD) remains the leading cause of death worldwide with approximately 1 in 30 patients with stable CAD experiencing death or acute myocardial infarction each year. The presence and extent of resultant myocardial ischaemia has been shown to confer an increased risk of adverse outcomes. Whilst, optimal medical therapy (OMT) forms the cornerstone of the management of patients with stable CAD, a significant number of patients present with ischaemia refractory to OMT. Historically coronary angiography alone has been used to determine coronary lesion severity in both stable and acute settings. It is increasingly clear that this approach fails to accurately identify the haemodynamic significance of lesions; especially those that are visually “intermediate” in severity. Revascularisation based upon angiographic appearances alone may not reduce coronary events above OMT. Technological advances have enabled the measurement of physiological indices including the fractional flow reserve, the index of microcirculatory resistance and the coronary flow reserve. The integration of these parameters into the routine management of patients presenting to the cardiac catheterization laboratory with CAD represents a critical adjunctive tool in the optimal management of these patients by identifying patients that would most benefit from revascularisation and importantly also highlighting patients that would not gain benefit and therefore reducing the likelihood of adverse outcomes associated with coronary revascularisation. Furthermore, these techniques are applicable to a broad range of patients including those with left main stem disease, proximal coronary disease, diabetes mellitus, previous percutaneous coronary intervention and with previous coronary artery bypass grafting. This review will discuss current concepts relevant to coronary physiology assessment, its role in the management of both stable and acute patients and future applications. PMID

  14. Role of coronary physiology in the contemporary management of coronary artery disease.

    Science.gov (United States)

    Ruparelia, Neil; Kharbanda, Rajesh K

    2015-02-16

    Coronary artery disease (CAD) remains the leading cause of death worldwide with approximately 1 in 30 patients with stable CAD experiencing death or acute myocardial infarction each year. The presence and extent of resultant myocardial ischaemia has been shown to confer an increased risk of adverse outcomes. Whilst, optimal medical therapy (OMT) forms the cornerstone of the management of patients with stable CAD, a significant number of patients present with ischaemia refractory to OMT. Historically coronary angiography alone has been used to determine coronary lesion severity in both stable and acute settings. It is increasingly clear that this approach fails to accurately identify the haemodynamic significance of lesions; especially those that are visually "intermediate" in severity. Revascularisation based upon angiographic appearances alone may not reduce coronary events above OMT. Technological advances have enabled the measurement of physiological indices including the fractional flow reserve, the index of microcirculatory resistance and the coronary flow reserve. The integration of these parameters into the routine management of patients presenting to the cardiac catheterization laboratory with CAD represents a critical adjunctive tool in the optimal management of these patients by identifying patients that would most benefit from revascularisation and importantly also highlighting patients that would not gain benefit and therefore reducing the likelihood of adverse outcomes associated with coronary revascularisation. Furthermore, these techniques are applicable to a broad range of patients including those with left main stem disease, proximal coronary disease, diabetes mellitus, previous percutaneous coronary intervention and with previous coronary artery bypass grafting. This review will discuss current concepts relevant to coronary physiology assessment, its role in the management of both stable and acute patients and future applications.

  15. Understanding the C-pulse device and its potential to treat heart failure.

    Science.gov (United States)

    Sales, Virna L; McCarthy, Patrick M

    2010-03-01

    The Sunshine Heart C-Pulse (C-Pulse; Sunshine Heart Inc., Tustin, CA) device is an extra-aortic implantable counterpulsation pump designed as a non-blood contacting ambulatory heart assist device, which may provide relief from symptoms for class II-III congestive heart failure patients. It has a comparable hemodynamic augmentation to intra-aortic balloon counterpulsation devices. The C-Pulse cuff is implanted through a median sternotomy, secured around the ascending aorta, and pneumatically driven by an external system controller. Pre-clinical studies in the acute pig model, and initial temporary clinical studies in patients undergoing off-pump coronary bypass surgery have shown substantial increase in diastolic perfusion of the coronary vessels, which translated to a favorable improvement in ventricular function. A U.S. prospective multi-center trial to evaluate the safety and efficacy of the C-Pulse in class III patients with moderate heart failure is now in progress.

  16. A Linear Electromagnetic Piston Pump

    Science.gov (United States)

    Hogan, Paul H.

    Advancements in mobile hydraulics for human-scale applications have increased demand for a compact hydraulic power supply. Conventional designs couple a rotating electric motor to a hydraulic pump, which increases the package volume and requires several energy conversions. This thesis investigates the use of a free piston as the moving element in a linear motor to eliminate multiple energy conversions and decrease the overall package volume. A coupled model used a quasi-static magnetic equivalent circuit to calculate the motor inductance and the electromagnetic force acting on the piston. The force was an input to a time domain model to evaluate the mechanical and pressure dynamics. The magnetic circuit model was validated with finite element analysis and an experimental prototype linear motor. The coupled model was optimized using a multi-objective genetic algorithm to explore the parameter space and maximize power density and efficiency. An experimental prototype linear pump coupled pistons to an off-the-shelf linear motor to validate the mechanical and pressure dynamics models. The magnetic circuit force calculation agreed within 3% of finite element analysis, and within 8% of experimental data from the unoptimized prototype linear motor. The optimized motor geometry also had good agreement with FEA; at zero piston displacement, the magnetic circuit calculates optimized motor force within 10% of FEA in less than 1/1000 the computational time. This makes it well suited to genetic optimization algorithms. The mechanical model agrees very well with the experimental piston pump position data when tuned for additional unmodeled mechanical friction. Optimized results suggest that an improvement of 400% of the state of the art power density is attainable with as high as 85% net efficiency. This demonstrates that a linear electromagnetic piston pump has potential to serve as a more compact and efficient supply of fluid power for the human scale.

  17. Acute Thrombotic Coronary Occlusion in a Patient with Coronary Artery Anomaly

    Directory of Open Access Journals (Sweden)

    Beganu Elena

    2017-09-01

    Full Text Available Patients with coronary artery anomalies are more susceptible to develop acute thrombotic coronary occlusions due to the abnormal anatomy of these arteries and the disturbance of the pathophysiological mechanisms that lead to an accelerated atherosclerosis development. The following article presents the case of a 64-year-old female patient diagnosed with anterior ST-segment elevation myocardial infarction. The patient underwent primary percutaneous coronary intervention, which revealed the absence of the right coronary artery and separated origins of the left anterior descending artery and the left circumflex artery from the aorta.

  18. Contribution of Genetic Background, Traditional Risk Factors, and HIV-Related Factors to Coronary Artery Disease Events in HIV-Positive Persons

    Science.gov (United States)

    Rotger, Margalida; Glass, Tracy R.; Junier, Thomas; Lundgren, Jens; Neaton, James D.; Poloni, Estella S.; van 't Wout, Angélique B.; Lubomirov, Rubin; Colombo, Sara; Martinez, Raquel; Rauch, Andri; Günthard, Huldrych F.; Neuhaus, Jacqueline; Wentworth, Deborah; van Manen, Danielle; Gras, Luuk A.; Schuitemaker, Hanneke; Albini, Laura; Torti, Carlo; Jacobson, Lisa P.; Li, Xiuhong; Kingsley, Lawrence A.; Carli, Federica; Guaraldi, Giovanni; Ford, Emily S.; Sereti, Irini; Hadigan, Colleen; Martinez, Esteban; Arnedo, Mireia; Egaña-Gorroño, Lander; Gatell, Jose M.; Law, Matthew; Bendall, Courtney; Petoumenos, Kathy; Rockstroh, Jürgen; Wasmuth, Jan-Christian; Kabamba, Kabeya; Delforge, Marc; De Wit, Stephane; Berger, Florian; Mauss, Stefan; de Paz Sierra, Mariana; Losso, Marcelo; Belloso, Waldo H.; Leyes, Maria; Campins, Antoni; Mondi, Annalisa; De Luca, Andrea; Bernardino, Ignacio; Barriuso-Iglesias, Mónica; Torrecilla-Rodriguez, Ana; Gonzalez-Garcia, Juan; Arribas, José R.; Fanti, Iuri; Gel, Silvia; Puig, Jordi; Negredo, Eugenia; Gutierrez, Mar; Domingo, Pere; Fischer, Julia; Fätkenheuer, Gerd; Alonso-Villaverde, Carlos; Macken, Alan; Woo, James; McGinty, Tara; Mallon, Patrick; Mangili, Alexandra; Skinner, Sally; Wanke, Christine A.; Reiss, Peter; Weber, Rainer; Bucher, Heiner C.; Fellay, Jacques; Telenti, Amalio; Tarr, Philip E.

    2013-01-01

    Background Persons infected with human immunodeficiency virus (HIV) have increased rates of coronary artery disease (CAD). The relative contribution of genetic background, HIV-related factors, antiretroviral medications, and traditional risk factors to CAD has not been fully evaluated in the setting of HIV infection. Methods In the general population, 23 common single-nucleotide polymorphisms (SNPs) were shown to be associated with CAD through genome-wide association analysis. Using the Metabochip, we genotyped 1875 HIV-positive, white individuals enrolled in 24 HIV observational studies, including 571 participants with a first CAD event during the 9-year study period and 1304 controls matched on sex and cohort. Results A genetic risk score built from 23 CAD-associated SNPs contributed significantly to CAD (P = 2.9×10−4). In the final multivariable model, participants with an unfavorable genetic background (top genetic score quartile) had a CAD odds ratio (OR) of 1.47 (95% confidence interval [CI], 1.05–2.04). This effect was similar to hypertension (OR = 1.36; 95% CI, 1.06–1.73), hypercholesterolemia (OR = 1.51; 95% CI, 1.16–1.96), diabetes (OR = 1.66; 95% CI, 1.10–2.49), ≥1 year lopinavir exposure (OR = 1.36; 95% CI, 1.06–1.73), and current abacavir treatment (OR = 1.56; 95% CI, 1.17–2.07). The effect of the genetic risk score was additive to the effect of nongenetic CAD risk factors, and did not change after adjustment for family history of CAD. Conclusions In the setting of HIV infection, the effect of an unfavorable genetic background was similar to traditional CAD risk factors and certain adverse antiretroviral exposures. Genetic testing may provide prognostic information complementary to family history of CAD. PMID:23532479

  19. Residential gas-fired sorption heat pumps. Test and technology evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Naeslund, M.

    2008-12-15

    Heat pumps may be the next step in gas-fired residential space heating. Together with solar energy it is an option to combine natural gas and renewable energy. Heat pumps for residential space heating are likely to be based on the absorption or adsorption process, i.e. sorption heat pumps. Manufacturers claim that the efficiency could reach 140-160%. The annual efficiency will be lower but it is clear that gas-fired heat pumps can involve an efficiency and technology step equal to the transition from non-condensing gas boilers with atmospheric burners to condensing boilers. This report contains a review of the current sorption gas-fired heat pumps for residential space heating and also the visible development trends. A prototype heat pump has been laboratory tested. Field test results from Germany and the Netherlands are also used for a technology evaluation. The tested heat pump unit combines a small heat pump and a supplementary condensing gas boiler. Field tests show an average annual efficiency of 120% for this prototype design. The manufacturer abandoned the tested design during the project period and the current development concentrates on a heat pump design only comprising the heat pump, although larger. The heat pump development at three manufacturers in Germany indicates a commercial stage around 2010-2011. A fairly high electricity consumption compared to traditional condensing boilers was observed in the tested heat pump. Based on current prices for natural gas and electricity the cost savings were estimated to 12% and 27% for heat pumps with 120% and 150% annual efficiency respectively. There is currently no widespread performance testing procedure useful for annual efficiency calculations of gas-fired heat pumps. The situation seems to be clearer for electric compression heat pumps regarding proposed testing and calculation procedures. A German environmental label exists and gasfired sorption heat pumps are also slightly treated in the Eco-design work

  20. Comparison of different insulin pump makes under routine care conditions in adults with Type 1 diabetes.

    Science.gov (United States)

    Leelarathna, L; Roberts, S A; Hindle, A; Markakis, K; Alam, T; Chapman, A; Morris, J; Urwin, A; Jinadev, P; Rutter, M K

    2017-10-01

    To compare long-term HbA 1c changes associated with different insulin pumps during routine care in a large cohort of adults with Type 1 diabetes representative of other clinic populations. Observational, retrospective study of 508 individuals starting pump therapy between 1999 and 2014 (mean age, 40 years; 55% women; diabetes duration, 20 years; 94% Type 1 diabetes; median follow-up, 3.7 years). Mixed linear models compared covariate-adjusted HbA 1c changes associated with different pump makes. The pumps compared were: 50% Medtronic, 24% Omnipod, 14% Roche and 12% Animas. Overall HbA 1c levels improved and improvements were maintained during a follow-up extending to 10 years (HbA 1c : pre-continuous subcutaneous insulin infusion (pre-CSII) vs. 12 months post CSII, 71 (61, 82) vs. 66 (56, 74) mmol/mol; 8.7 (7.7, 9.6) vs. 8.2 (7.3, 8.9)%; P < 0.0001). The percentage of individuals with HbA 1c ≥ 64 mmol/mol (8.0%) reduced from a pre-CSII level of 68% to 55%. After adjusting for baseline confounders, there were no between-pump differences in HbA 1c lowering (P = 0.44), including a comparison of patch pumps with traditional catheter pumps (P = 0.63). There were no significant (P < 0.05) between-pump differences in HbA 1c lowering in pre-specified subgroups stratified by pre-pump HbA 1c , age or diabetes duration. HbA 1c lowering was positively related to baseline HbA 1c (P < 0.001) and diabetes duration (P = 0.017), and negatively related to the number of years of CSII use (P = 0.024). Under routine care conditions, there were no covariate-adjusted differences in HbA 1c lowering when comparing different pump makes, including a comparison of patch pumps vs. traditional catheter pumps. Therefore, the choice of CSII make should not be influenced by the desired degree of HbA 1c lowering. © 2017 Diabetes UK.

  1. Association of coronary heart disease with age-adjusted aortocoronary calcification in patients with familial hypercholesterolaemia

    DEFF Research Database (Denmark)

    Jensen, J M; Gerdes, Lars Ulrik; Jensen, H K

    2000-01-01

    OBJECTIVES: Existing algorithms of risk of coronary heart disease (CHD) do not pertain to patients with familial hypercholesterolaemia (FH), whose arteries have been exposed to hypercholesterolaemia since birth. We studied a cohort of FH patients to compare four diagnostic models of CHD: traditio......OBJECTIVES: Existing algorithms of risk of coronary heart disease (CHD) do not pertain to patients with familial hypercholesterolaemia (FH), whose arteries have been exposed to hypercholesterolaemia since birth. We studied a cohort of FH patients to compare four diagnostic models of CHD......: traditional risk factors of CHD (age, sex, cholesterol, hypertension, smoking and body mass index), cholesterol year score, and aortic as well as coronary calcium measured by spiral computed tomography (CT). SUBJECTS: We invited 88 individuals with molecularly defined FH of whom 80 (91%) decided...

  2. Factors influencing delay time and coronary arterial density during coronary angiography with DSCT

    International Nuclear Information System (INIS)

    Lijun Tang; Xiaomei Zhu; Yi Xu; Tongfu Yu; Hai Xu; Jinhua Tang; Dehang Wang; Dogra, Vikram

    2011-01-01

    Background: CT angiography (CTA) plays an important role in diagnosing coronary arterial disease. Delay time and density of the coronary arteries related with patient-specific factors are essential for getting an optimal CTA image. Purpose: To investigate various factors influencing delay time and coronary arterial density during coronary CTA with dual source CT. Material and Methods: One hundred and sixteen consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Factors including gender, age, height, weight, transversal cardiac diameter (TCD), transversal thoracic diameter (TTD), heart rate (HR), body surface area (BSA = [weight x height/3600]1/2) and cardiothoracic ratio (CTR = TCD/TTD) were recorded, measured and calculated before administration of contrast media during coronary CT angiography. Delay time was determined as duration from the beginning of the injection to the density in the descending aorta at the level of right main pulmonary artery reaching a threshold of 100 HU. Coronary arterial density was measured at the mid portion of the right coronary artery. Regression analysis and stepwise regression analysis were used to investigate the influence of these factors on delay time and coronary arterial density. Results: Delay time decreased with an increasing HR and it was shorter in women than men. Delay time increased with an increasing TCD. Delay time could be predicted by the formula: DT = 16.651-0.110 x HR + 1.902 x gender + 0.394 x TCD (where DT is abbreviation for delay time, gender is 0 for women and 1 for men). Coronary arterial density decreased with an increasing HR and weight. Coronary arterial density could be predicted by the formula: CAD = 923.42-4.099 x HR-3.293 x weight (CAD = coronary arterial density). There was no relationship between the other factors mentioned above and delay time or coronary arterial density. Conclusion: Delay time is influenced by HR, gender and TCD. Coronary arterial density

  3. Implementation of an RHR/LPSI pump coupling retrofit program

    International Nuclear Information System (INIS)

    Dudiak, J.G.; Koch, R.P.; Orewyler, R.; Tipton, J.W.

    1994-01-01

    Nuclear plant operating experience has shown the RHR and LPSI services to be very demanding on pumps. The systems handle borated water at high temperatures and pressures with frequent step changes in both temperature and pressure. Additionally, the industry trend towards reduced flow rates during plant mid-loop (reduced inventory) conditions has resulted in extended pump operation at flow rates significantly below the pump best efficiency point flow. Operation at these low flow fates is known to cause high thrust loads and large shaft deflections. The combination of these and other factors have resulted in short mechanical seal life and short motor bearing life, thus requiring frequent pump and motor maintenance. For many nuclear plants, including Southern California Edison's (SCE) San Onofre Units 2 and 3, these pumps have represented a major operations and maintenance (O ampersand M) expenditure and a significant source of radiation exposure to plant personnel. SCE management determined that a pump upgrade was justified to reduce the O ampersand M costs and to improve plant availability. SCE decided to proceed with a pump retrofit program to improve the pump maintainability, reliability and availability. Installation was completed for four LPSI pumps at San Onofre Units 2 and 3 during the Cycle 7 refueling outages in 1993. A key to the program's success was the removal of many traditional supplier and customer barriers and revision of supplier and customer roles to create a unified team. This paper traces the RHR/LPSI retrofit program for San Onofre from problem identification to project implementation. The team approach used for this program and the lessons learned may be useful to other utilities and vendors when evaluating or implementing system and equipment upgrades

  4. Resting Pd/Pa and haemodynamic relevance of coronary stenosis as evaluated by fractional flow reserve.

    Science.gov (United States)

    De Luca, Giuseppe; Verdoia, Monica; Barbieri, Lucia; Marino, Paolo; Suryapranata, Harry

    2018-03-01

    Fractional flow reserve (FFR) currently represents the gold standard in the evaluation of the haemodynamic relevance of coronary stenoses. However, both intracoronary and intravenous adenosine may be tolerated poorly by some patients. Therefore, considerable interest had been focused in the last few years on new adenosine-free indexes to define the haemodynamic relevance of coronary stenoses. So far, few data have been reported on resting Pd/Pa and its correlation with FFR as evaluated with high-dose intracoronary adenosine administration, which is the aim of the current study. FFR was assessed in 120 patients with 137 intermediate lesions during cardiac catheterization by a pressure-recording guidewire (PrimeWire). FFR was calculated as the ratio of the distal coronary pressure to the aortic pressure at hyperaemia. Intracoronary doses of adenosine were administered up to 720 μg as intracoronary boli. Exclusion criteria were as follows: (a) allergy to adenosine; (b) baseline bradycardia (heart rate values and increased the percentage of patients showing an FFR less than 0.80. Resting Pd/Pa showed good accuracy in the identification of patients with significant FFR values (value in the prediction of a positive FFR value. A value up to 0.88 was associated with a 100% positive predictive value, whereas a value of at least 0.95 was associated with a 95% negative predictive value. This study showed that in intermediate lesions, resting Pd/Pa was related linearly to FFR. We identified 0.93 as the best cut-off value in the prediction of haemodynamically significant coronary stenosis as evaluated by FFR. However, cut-off values of 0.88 and 0.95 could provide the maximal predictive positive and negative values, suggesting the additional use of FFR only in patients with resting values within this range.

  5. Short- and Long-term Outcomes in Patients with Connective Tissue Diseases Undergoing Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Li Zhou

    2016-01-01

    Conclusions: Patients with CTD and CAD may have severe coronary lesions. PCI in these patients tends to result in an increased rate of stent thrombosis and TVR during long-term follow-up, which may be influenced by traditional and nontraditional risk factors.

  6. Pre-compression volume on flow ripple reduction of a piston pump

    Science.gov (United States)

    Xu, Bing; Song, Yuechao; Yang, Huayong

    2013-11-01

    Axial piston pump with pre-compression volume(PCV) has lower flow ripple in large scale of operating condition than the traditional one. However, there is lack of precise simulation model of the axial piston pump with PCV, so the parameters of PCV are difficult to be determined. A finite element simulation model for piston pump with PCV is built by considering the piston movement, the fluid characteristic(including fluid compressibility and viscosity) and the leakage flow rate. Then a test of the pump flow ripple called the secondary source method is implemented to validate the simulation model. Thirdly, by comparing results among the simulation results, test results and results from other publications at the same operating condition, the simulation model is validated and used in optimizing the axial piston pump with PCV. According to the pump flow ripples obtained by the simulation model with different PCV parameters, the flow ripple is the smallest when the PCV angle is 13°, the PCV volume is 1.3×10-4 m3 at such operating condition that the pump suction pressure is 2 MPa, the pump delivery pressure 15 MPa, the pump speed 1 000 r/min, the swash plate angle 13°. At the same time, the flow ripple can be reduced when the pump suction pressure is 2 MPa, the pump delivery pressure is 5 MPa,15 MPa, 22 MPa, pump speed is 400 r/min, 1 000 r/min, 1 500 r/min, the swash plate angle is 11°, 13°, 15° and 17°, respectively. The finite element simulation model proposed provides a method for optimizing the PCV structure and guiding for designing a quieter axial piston pump.

  7. Multiple Culprit Coronary Artery Thrombosis in a Patient with Coronary Ectasia

    Directory of Open Access Journals (Sweden)

    Bruno da Silva Matte

    2018-01-01

    Full Text Available We here report a case of ST-elevation myocardial infarction (STEMI due to simultaneous acute coronary artery occlusions of two major coronary arteries in a patient with coronary ectasia. The patient had been previously submitted to percutaneous coronary angioplasty with bare metal stent implantation in both culprit vessels. Very late stent thrombosis could be the cause of the first occlusion, triggering the event in the other vessel. In addition, concomitant embolic sources were not identified. Although routine aspiration thrombectomy in STEMI was not proven to be beneficial in randomized clinical trials, it was of great value in this case. We also discuss the relation between coronary ectasia, chronic inflammatory status, and increased platelet activity which may have caused plaque disruption in another already vulnerable vessel.

  8. [Experimental evaluation of the role of the coronary sinus pressure in the regulation of coronary return volume via the coronary sinus. Surgical considerations in atrio-pulmonary diversion procedures].

    Science.gov (United States)

    Fantidis, P; Fernández Ruiz, M A; Madero Jarabo, R; Moreno Granados, F; Cordovilla Zurdo, G; Sanz Galeote, E

    1990-11-01

    In order to find out the validity of the vascular waterfall mechanism in coronary venous circulation, the role of coronary sinus pressure in the regulation of coronary return volume via the coronary sinus is studied in healthy animals. An experimental model of pressure regulation in the coronary sinus was prepared, and aortic pressure, EKG and the cardiac output (measured by thermodilution) were recorded. The return volume via the coronary sinus was measured at coronary sinus pressure of 10 or less, 15, 20, and 25 mmHg or more, for a total of 36 determinations. Increased coronary sinus pressure did not produce significant changes in aortic pressure, heart rate, cardiac index or coronary return volume via coronary sinus. When coronary sinus pressure was 25 mmHg or more, there was a significant decline in the average of coronary return volume via coronary sinus. Nevertheless, stepwise variant regression showed that the coronary sinus pressure per se does not condition the volume of coronary return via the coronary sinus. Our results suggest that in the healthy animals, the vascular waterfall mechanism in coronary venous circulation is not valid. Our results suggest that in the correction of congenital cardiac malformations using atriopulmonary anastomosis procedures, employing techniques that ensure coronary sinus drainage into the left atrium, in order to avoid the hemodynamic repercussions attributable to the vascular waterfall mechanism, is not justified.

  9. Renewable Energy for Water Pumping Applications In Rural Villages; Period of Performance: April 1, 2001--September 1, 2001

    Energy Technology Data Exchange (ETDEWEB)

    Argaw, N.; Foster, R.; Ellis, A.

    2003-07-01

    This report introduces conventional and renewable energy sources for water pumping applications in rural villages by reviewing the technologies and illustrating typical applications. As energy sources for water pumping, the report discusses diesel/gasoline/kerosene engines, grid power supplies, traditional windmills, electrical wind turbines, and PV.

  10. The pumping of hydrogen and helium by sputter-ion pumps

    International Nuclear Information System (INIS)

    Welch, K.M.; Pate, D.J.; Todd, R.J.

    1992-01-01

    The pumping of hydrogen in diode and triode sputter-ion pumps is discussed. The type of cathode material used in these pumps is shown to have a significant impact on the effectiveness with which hydrogen is pumped. Examples of this include data for pumps with aluminum and titanium-alloy cathodes. Diode pumps with aluminum cathodes are shown to be no more effective in the pumping of hydrogen than in the pumping of helium. The use of titanium or titanium alloy anodes is also shown to measurably impact on the speed of these pumps at.very low pressures. This stems from the fact that hydrogen is x10 6 more soluble in titanium than in stainless steel. Hydrogen becomes resident in the anodes because of fast neutral burial. Lastly, quantitative data are given for the He speeds and capacities of both noble and conventional diode and triode pumps. The effectiveness of various pump regeneration procedures, subsequent to the pumping of He, is reported.These included bakeout and N 2 glow discharge cleaning. The comparative desorption of He with the subsequent pumping of N 2 is reported on. The N 2 speed of these pumps was used as the benchmark for defining the size of the pumps vs. their respective He speeds

  11. The Technology Endowments of Spin-off Companies

    OpenAIRE

    E. VAN DE VELDE; B. CLARYSSE; M. WRIGHT

    2008-01-01

    Innovative start-ups, including spin-offs from universities and companies, play a vital role in the development and growth of emerging, high-technology industries. Research attention has traditionally focused on the links between demographic, educational, psychological and financial influences on start-up activity and growth. The extent to which the characteristics of technology inherited from the parent, important for spin-offs, helps explain post start-up performance has been neglected. We ...

  12. SURGERY OF SYMPTOMATIC MYOCARDIAL BRIDGING

    Directory of Open Access Journals (Sweden)

    N. Maghamipour N. Safaei

    2007-06-01

    Full Text Available Myocardial bridging with systolic compression of the left anterior descending coronary artery (LAD may be associated with myocardial ischemia. In symptomatic myocardial bridging unresponsive to medical treatment, surgical unroofing of the left LAD can be performed. Little information is available about the long-term prognosis of patients with this coronary anomaly after the surgical unroofing, so we decided to evaluate the result of this operation. A total of 26 patients underwent surgical unroofing of myocardial bridging. Patients had a myocardial bridge of at least 3 cm in length in the middle of LAD and with more than 70% compression during systole. Unroofing was performed with cardiopulmonary bypass in 16 and with off pump technique in 10 patients. In 6 patients repeat angiographies for control of myotomy were done. In one of them a nonsignificant 20% narrowing was seen. Postoperative scintigraphic and angiographic studies demonstrated restoration of coronary flow and myocardial perfusion without residual myocardial bridges under beta-stimulation in 24 patients. Two patients had residual narrowing. With off pump technique, 1 patient had perforation of the right ventricle and 1 patient underwent reoperation because of incomplete unroofing during the first operation. None of the patients with cardiopulmonary bypass technique had residual chest pain or other complications. Surgical unroofing of myocardial bridging with the aid of cardiopulmonary bypass is a safe and easy procedure with low operative risk and with excellent functional results.

  13. Liquid metals pumping

    International Nuclear Information System (INIS)

    Le Frere, J.P.

    1984-01-01

    Pumps used to pump liquid metals depend on the liquid metal and on the type of application concerned. One deals more particularly with electromagnetic pumps, the main pumps used with mechanical pumps. To pump sodium in the nuclear field, these two types of pumps are used; the pumps of different circuits of Super Phenix are presented and described [fr

  14. Implementation of Wolsong Pump Model, Pressure Tube Deformation Model and Off-take Model into MARS Code for Regulatory Auditing of CANDU Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, C.; Rhee, B. W.; Chung, B. D. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Y. J.; Kim, M. W. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2008-05-15

    Korea currently has four operating units of the CANDU-6 type reactor in Wolsong. However, the safety assessment system for CANDU reactors has not been fully established due to lack of self-reliance technology. Although the CATHENA code had been introduced from AECL, it is undesirable to use vendor's code for regulatory auditing analysis. In Korea, the MARS code has been developed for decades and is being considered by KINS as a thermal hydraulic regulatory auditing tool for nuclear power plants. Before this decision, KINS (Korea Institute of Nuclear Safety) had developed RELAP5/MOD3/CANDU code for CANDU safety analyses by modifying the model of existing PWR auditing tool, RELAP5/MOD3. The main purpose of this study is to transplant the CANDU models of RELAP5/MOD3/CANDU code to MARS code including quality assurance of the developed models. This first part of the research series presents the implementation and verification of the Wolsong pump model, the pressure tube deformation model, and the off-take model for arbitrary-angled branch pipes.

  15. Implementation of Wolsong Pump Model, Pressure Tube Deformation Model and Off-take Model into MARS Code for Regulatory Auditing of CANDU Reactors

    International Nuclear Information System (INIS)

    Yoon, C.; Rhee, B. W.; Chung, B. D.; Cho, Y. J.; Kim, M. W.

    2008-01-01

    Korea currently has four operating units of the CANDU-6 type reactor in Wolsong. However, the safety assessment system for CANDU reactors has not been fully established due to lack of self-reliance technology. Although the CATHENA code had been introduced from AECL, it is undesirable to use vendor's code for regulatory auditing analysis. In Korea, the MARS code has been developed for decades and is being considered by KINS as a thermal hydraulic regulatory auditing tool for nuclear power plants. Before this decision, KINS (Korea Institute of Nuclear Safety) had developed RELAP5/MOD3/CANDU code for CANDU safety analyses by modifying the model of existing PWR auditing tool, RELAP5/MOD3. The main purpose of this study is to transplant the CANDU models of RELAP5/MOD3/CANDU code to MARS code including quality assurance of the developed models. This first part of the research series presents the implementation and verification of the Wolsong pump model, the pressure tube deformation model, and the off-take model for arbitrary-angled branch pipes

  16. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  17. Coronary artery anomalies in adults: imaging at dual source CT coronary angiography

    International Nuclear Information System (INIS)

    Laspas, Fotios; Roussakis, Arkadios; Mourmouris, Christos; Kritikos, Nikolaos; Efthimiadou, Roxani; Andreou, John

    2013-01-01

    Congenital abnormalities of the coronary arteries have an incidence of 1%, and most of these are benign. However, a small number are associated with myocardial ischaemia and sudden death. Various imaging modalities are available for coronary artery assessment. Recently, multi-detector CT has emerged as an accurate diagnostic tool for defining coronary artery anomalies. The purpose of this pictorial essay is to review the dual source CT appearance of congenital anomalies of the coronary arteries in adults.

  18. Ethical Perspective: Five Unacceptable Trade-offs on the Path to Universal Health Coverage

    Directory of Open Access Journals (Sweden)

    Ole Frithjof Norheim

    2015-11-01

    Full Text Available This article discusses what ethicists have called “unacceptable trade-offs” in health policy choices related to universal health coverage (UHC. Since the fiscal space is constrained, trade-offs need to be made. But some trade-offs are unacceptable on the path to universal coverage. Unacceptable choices include, among other examples from low-income countries, to expand coverage for services with lower priority such as coronary bypass surgery before securing universal coverage for high-priority services such as skilled birth attendance and services for easily preventable or treatable fatal childhood diseases. Services of the latter kind include oral rehydration therapy for children with diarrhea and antibiotics for children with pneumonia. The article explains why such trade-offs are unfair and unacceptable even if political considerations may push in the opposite direction.

  19. The value of coronary artery calcium score assessed by dual-source computed tomography coronary angiography for predicting presence and severity of coronary artery disease

    International Nuclear Information System (INIS)

    Almasi, Alireza; Pouraliakbar, Hamidreza; Sedghian, Ahmad; Karimi, Mohammad Ali; Firouzi, Ata; Tehrai, Mahmood

    2014-01-01

    Measuring coronary artery calcium score (CACS) using a dual-source CT scanner is recognized as a major indicator for assessing coronary artery disease. The present study aimed to validate the clinical significance of CACS in predicting coronary artery stenosis and its severity. This prospective study was conducted on 202 consecutive patients who underwent both conventional coronary angiography and dual-source (256-slice) computed tomography coronary angiography (CTA) for any reason in our cardiac imaging center from March to September 2013. CACS was measured by Agatston algorithm on non-enhanced CT. The severity of coronary artery disease was assessed by Gensini score on conventional angiography. There was a significant relationship between the number of diseased coronary vessels and mean calcium score, i.e. the mean calcium score was 202.25±450.06 in normal coronary status, 427.50±607.24 in single-vessel disease, 590.03±511.34 in two-vessel disease, and 953.35±1023.45 in three-vessel disease (p<0.001). There was a positive association between calcium score and Gensini score (r=0.636, p<0.001). In a linear regression model, calcium score was a strong determinant of the severity of coronary artery disease. Calcium scoring had an acceptable value for discriminating coronary disease from normal condition with optimal cutoff point of 350, yielding a sensitivity and specificity of 83% and 70%, respectively. Our study confirmed the strong relationship between the coronary artery calcium score and the presence and severity of stenosis in coronary arteries assessed by both the number of diseased coronary vessels and also by the Gnesini score

  20. Slip flow coefficient analysis in water hydraulics gear pump for environmental friendly application

    International Nuclear Information System (INIS)

    Yusof, A A; Wasbari, F; Zakaria, M S; Ibrahim, M Q

    2013-01-01

    Water hydraulics is the sustainable option in developing fluid power systems with environmental friendly approach. Therefore, an investigation on water-based external gear pump application is being conducted, as a low cost solution in the shifting effort of using water, instead of traditional oil hydraulics in fluid power application. As the gear pump is affected by fluid viscosity, an evaluation has been conducted on the slip flow coefficient, in order to understand to what extent the spur gear pump can be used with water-based hydraulic fluid. In this paper, the results of a simulated study of variable-speed fixed displacement gear pump are presented. The slip flow coefficient varies from rotational speed of 250 RPM to 3500 RPM, and provides volumetric efficiency ranges from 9 % to 97% accordingly

  1. Development of Coronary Pulse Wave Velocity: New Pathophysiological Insight Into Coronary Artery Disease.

    Science.gov (United States)

    Harbaoui, Brahim; Courand, Pierre-Yves; Cividjian, Andrei; Lantelme, Pierre

    2017-02-02

    Although aortic stiffness assessed by pulse wave velocity (PWV) is a strong predictor of coronary artery disease, the significance of local coronary stiffness has never been tackled. The first objective of this study was to describe a method of measuring coronary PWV (CoPWV) invasively and to describe its determinants. The second objective was to assess both CoPWV and aortic PWV in patients presenting with acute coronary syndromes or stable coronary artery disease. In 53 patients, CoPWV was measured from the delay in pressure wave and distance traveled as a pressure wire was withdrawn from the distal to the proximal coronary segment. Similarly, aortic PWV was measured invasively when the wire was pulled across the ascending aorta; carotid-femoral PWV was also measured noninvasively using the SphygmoCor system (AtCor Medical). Mean CoPWV was 10.3±6.1 m/s. Determinants of increased CoPWV were fractional flow reserve, diastolic blood pressure, and previous stent implantation in the recorded artery. CoPWV was lower in patients with acute coronary syndromes versus stable coronary artery disease (7.6±3 versus 11.5±6.4 m/s; P=0.02), and this persisted after adjustment for confounders. In contrast, aortic stiffness, assessed by aortic and carotid-femoral PWV, did not differ significantly. CoPWV seems associated with acute coronary events more closely than aortic PWV. High coronary compliance, whether per se or because it leads to a distal shift in compliance mismatch, may expose vulnerable plaques to high cyclic stretch. CoPWV is a new tool to assess local compliance at the coronary level; it paves the way for a new field of research. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  2. Continuously pumping and reactivating gas pump

    International Nuclear Information System (INIS)

    Batzer, T.H.; Call, W.R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped

  3. Continuously pumping and reactivating gas pump

    Science.gov (United States)

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  4. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  5. Viability of using different types of main oil pipelines pump drives

    Science.gov (United States)

    Zakirzakov, A. G.; Zemenkov, Yu D.; Akulov, K. A.

    2018-05-01

    The choice of the pumping units' drive of main oil pipelines is of great importance both for design of pipelines and for modernization of existing ones. At the beginning of oil pipeline transport development, due to the limited number and types of energy sources, the choice was not difficult. The combustion energy of the pumped product was often the only available energy resource for its transportation. In this regard, the pipelines that had autonomous energy sources favorably differed from other energy consumers in the sector. With the passage of time, with the development of the country's electricity supply system, the electric drive for power-line equipment of oil pipelines becomes the dominant type of a pumping station drive. Nowadays, the traditional component is an essential factor when choosing some type of the drive. For many years, oil companies have been using electric drives for pumps, while gas transport enterprises prefer self-contained gas turbines.

  6. Balloon Occlusion Types in the Treatment of Coronary Perforation during Percutaneous Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Xiangfei Wang

    2014-01-01

    Full Text Available Coronary artery perforation is an uncommon complication in patients with coronary heart disease undergoing percutaneous coronary intervention. However, pericardial tamponade following coronary artery perforation may be lethal, and prompt treatment is crucial in managing such patients. Balloon occlusion and the reversal of anticoagulant activity are the common methods used to prevent cardiac tamponade by reducing the amount of bleeding. Herein, we discuss the pros and cons of currently used occlusion types for coronary perforation. Optimal balloon occlusion methods should reduce the amount of bleeding and ameliorate subsequent myocardial ischemia injury, even during cardiac surgery.

  7. Energy-Saving Optimization of Water Supply Pumping Station Life Cycle Based on BIM Technology

    Science.gov (United States)

    Qun, Miao; Wang, Jiayuan; Liu, Chao

    2017-12-01

    In the urban water supply system, pump station is the main unit of energy consumption. In the background of pushing forward the informatization in China, using BIM technology in design, construction and operations of water supply pumping station, can break through the limitations of the traditional model and effectively achieve the goal of energy conservation and emissions reduction. This work researches the way to solve energy-saving optimization problems in the process of whole life cycle of water supply pumping station based on BIM technology, and put forward the feasible strategies of BIM application in order to realize the healthy and sustainable development goals by establishing the BIM model of water supply pumping station of Qingdao Guzhenkou water supply project.

  8. A Comparative Assessment of Spalart-Shur Rotation/Curvature Correction in RANS Simulations in a Centrifugal Pump Impeller

    Directory of Open Access Journals (Sweden)

    Ran Tao

    2014-01-01

    Full Text Available RANS simulation is widely used in the flow prediction of centrifugal pumps. Influenced by impeller rotation and streamline curvature, the eddy viscosity models with turbulence isotropy assumption are not accurate enough. In this study, Spalart-Shur rotation/curvature correction was applied on the SST k-ω turbulence model. The comparative assessment of the correction was proceeded in the simulations of a centrifugal pump impeller. CFD results were compared with existing PIV and LDV data under the design and low flow rate off-design conditions. Results show the improvements of the simulation especially in the situation that turbulence strongly produced due to undesirable flow structures. Under the design condition, more reasonable turbulence kinetic energy contour was captured after correction. Under the low flow rate off-design condition, the prediction of turbulence kinetic energy and velocity distributions became much more accurate when using the corrected model. So, the rotation/curvature correction was proved effective in this study. And, it is also proved acceptable and recommended to use in the engineering simulations of centrifugal pump impellers.

  9. Design and Thermodynamic Analysis of a Steam Ejector Refrigeration/Heat Pump System for Naval Surface Ship Applications

    Directory of Open Access Journals (Sweden)

    Cüneyt Ezgi

    2015-12-01

    Full Text Available Naval surface ships should use thermally driven heating and cooling technologies to continue the Navy’s leadership role in protecting the marine environment. Steam ejector refrigeration (SER or steam ejector heat pump (SEHP systems are thermally driven heating and cooling technologies and seem to be a promising technology to reduce emissions for heating and cooling on board naval surface ships. In this study, design and thermodynamic analysis of a seawater cooled SER and SEHP as an HVAC system for a naval surface ship application are presented and compared with those of a current typical naval ship system case, an H2O-LiBr absorption heat pump and a vapour-compression heat pump. The off-design study estimated the coefficient of performances (COPs were 0.29–0.11 for the cooling mode and 1.29–1.11 for the heating mode, depending on the pressure of the exhaust gas boiler at off-design conditions. In the system operating at the exhaust gas boiler pressure of 0.2 MPa, the optimum area ratio obtained was 23.30.

  10. Localization of fluctuation measurement by wave scattering close to a cut off layer

    International Nuclear Information System (INIS)

    Zou, X.L.; Laurent, L.; Rax, J.M.; Lehner, T.

    1990-01-01

    The diagnostic of plasma fluctuations in tokamaks based on the scattering of an electromagnetic wave close to a cut off layer is investigated. A linear density profile is considered. An one-dimensional exact analysis is performed. Spatial and spectral localization of scattering process close to the cut off layer is studied and a modified Bragg rule is derived. The structure of pump and of scattered waves is analyzed. The diagnostic seems to be local and sensitive for low R fluctuations

  11. Effect of pump limiter throat on pumping efficiency

    International Nuclear Information System (INIS)

    Ghendrih, P.; Grosman, A.; Samain, A.; Capes, H.; Morera, J.P.

    1988-01-01

    The necessary control of plasma edge density has led to the development of pump limiters to achieve this task. On Tore Supra, where a large part of the program is devoted to plasma edge studies, two types of such density control apparatus have been implemented, a set of pump limiters and the pumps associated to the ergodic divertor (magnetically assisted pump limiters). Generally two different kinds of pump limiters can be used, those with a throat which drives the plasma from the open edge plasma (SOL) to the neutralizer plate, and those without or with a very short throat. We are interested here in this aspect of the pump limiter concept, i.e. on the throat effect on neutral density build-up in the vicinity of the pumping plates (and hence on pumping efficieny). The underlying idea of this throat effect can be readily understood; indeed while the neutral capture in pump limiters without throats is only a ballistic effect, on expects the plasma to improve the efficiency of pump-limiters via plasma-neutral-sidewall interactions in the throat. This problem has been studied both numerically and analytically. The paper is divided as follows. In section 2, we describe the basic features of pump-limiters which are modelized by the numerical code Cezanne. Section 3 is devoted to the throat length effect considering in particular the neutral density profile in the throat and the neutral density buil-up as a function of the throat lenght. In section 4, we show that the plugging effect occurs for reasonnable values of throat lengths. An analytical value of the plugging length is discussed and compared to the values obtained numerically

  12. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  13. Finite-momentum condensation in a pumped microcavity

    International Nuclear Information System (INIS)

    Brierley, R. T.; Eastham, P. R.

    2010-01-01

    We calculate the absorption spectra of a semiconductor microcavity into which a nonequilibrium exciton population has been pumped. We predict strong peaks in the spectrum corresponding to collective modes analogous to the Cooper modes in superconductors and fermionic atomic gases. These modes can become unstable, leading to the formation of off-equilibrium quantum condensates. We calculate a phase diagram for condensation and show that the dominant instabilities can be at a finite momentum. Thus we predict the formation of inhomogeneous condensates, similar to Fulde-Ferrel-Larkin-Ovchinnikov states.

  14. Analysis and Recognition of Traditional Chinese Medicine Pulse Based on the Hilbert-Huang Transform and Random Forest in Patients with Coronary Heart Disease

    Directory of Open Access Journals (Sweden)

    Rui Guo

    2015-01-01

    Full Text Available Objective. This research provides objective and quantitative parameters of the traditional Chinese medicine (TCM pulse conditions for distinguishing between patients with the coronary heart disease (CHD and normal people by using the proposed classification approach based on Hilbert-Huang transform (HHT and random forest. Methods. The energy and the sample entropy features were extracted by applying the HHT to TCM pulse by treating these pulse signals as time series. By using the random forest classifier, the extracted two types of features and their combination were, respectively, used as input data to establish classification model. Results. Statistical results showed that there were significant differences in the pulse energy and sample entropy between the CHD group and the normal group. Moreover, the energy features, sample entropy features, and their combination were inputted as pulse feature vectors; the corresponding average recognition rates were 84%, 76.35%, and 90.21%, respectively. Conclusion. The proposed approach could be appropriately used to analyze pulses of patients with CHD, which can lay a foundation for research on objective and quantitative criteria on disease diagnosis or Zheng differentiation.

  15. Analysis and Recognition of Traditional Chinese Medicine Pulse Based on the Hilbert-Huang Transform and Random Forest in Patients with Coronary Heart Disease

    Science.gov (United States)

    Wang, Yiqin; Yan, Hanxia; Yan, Jianjun; Yuan, Fengyin; Xu, Zhaoxia; Liu, Guoping; Xu, Wenjie

    2015-01-01

    Objective. This research provides objective and quantitative parameters of the traditional Chinese medicine (TCM) pulse conditions for distinguishing between patients with the coronary heart disease (CHD) and normal people by using the proposed classification approach based on Hilbert-Huang transform (HHT) and random forest. Methods. The energy and the sample entropy features were extracted by applying the HHT to TCM pulse by treating these pulse signals as time series. By using the random forest classifier, the extracted two types of features and their combination were, respectively, used as input data to establish classification model. Results. Statistical results showed that there were significant differences in the pulse energy and sample entropy between the CHD group and the normal group. Moreover, the energy features, sample entropy features, and their combination were inputted as pulse feature vectors; the corresponding average recognition rates were 84%, 76.35%, and 90.21%, respectively. Conclusion. The proposed approach could be appropriately used to analyze pulses of patients with CHD, which can lay a foundation for research on objective and quantitative criteria on disease diagnosis or Zheng differentiation. PMID:26180536

  16. Non-invasive assessment of coronary calcification

    International Nuclear Information System (INIS)

    Vliegenthart, Rozemarijn; Oei, Hok-Hay S.; Hofman, Albert; Oudkerk, Matthijs; Witteman, Jackqueline C. M.

    2004-01-01

    Electron-beam tomography (EBT) and multi-detector computed tomography (MDCT) enable the noninvasive assessment of coronary calcification. The amount of coronary calcification, as detected by EBT, has a close relation with the amount of coronary atherosclerosis, which is the substrate for the occurrence of myocardial infarction and sudden cardiac death. Calcification of the coronary arteries can be seen as a cumulative measure of life-time exposure to cardiovascular risk factors. Several studies have shown that the amount of coronary calcification is associated with the risk of coronary heart disease. Therefore, coronary calcification is a promising method for non-invasive detection of asymptomatic subjects at high risk of developing coronary heart disease. Whether measurement of coronary calcification also increases the predictive power of coronary events based on cardiovascular risk factors is topic of current research

  17. [Pregnancy and coronary artery dissection].

    Science.gov (United States)

    Martínez-Quintana, Efrén; Rodríguez-González, Fayna

    2015-01-01

    Acute myocardial infarction during pregnancy is associated with high maternal and fetal mortality. Coronary atherosclerosis is the most common cause due to an increase in the age of the patients and the association with cardiovascular risk factors such as smoking, hypertension, diabetes mellitus, preeclampsia, and the existence of family history of coronary disease. However, thrombosis, coronary dissection or coronary vasospasms are other causes that may justify it. We report the case of a 33 weeks pregnant first-time mother, without cardiovascular risk factors, who presented an acute coronary event in the context of atherosclerotic disease and coronary dissection after percutaneous coronary intervention. Copyright © 2014 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  18. Study of Hydrogen Pumping through Condensed Argon in Cryogenic pump

    International Nuclear Information System (INIS)

    Jadeja, K A; Bhatt, S B

    2012-01-01

    In ultra high vacuum (UHV) range, hydrogen is a dominant residual gas in vacuum chamber. Hydrogen, being light gas, pumping of hydrogen in this vacuum range is limited with widely used UHV pumps, viz. turbo molecular pump and cryogenic pump. Pre condensed argon layers in cryogenic pump create porous structure on the surface of the pump, which traps hydrogen gas at a temperature less than 20° K. Additional argon gas injection in the cryogenic pump, at lowest temperature, generates multiple layers of condensed argon as a porous frost with 10 to 100 A° diameters pores, which increase the pumping capacity of hydrogen gas. This pumping mechanism of hydrogen is more effective, to pump more hydrogen gas in UHV range applicable in accelerator, space simulation etc. and where hydrogen is used as fuel gas like tokamak. For this experiment, the cryogenic pump with a closed loop refrigerator using helium gas is used to produce the minimum cryogenic temperature as ∼ 14° K. In this paper, effect of cryosorption of hydrogen is presented with different levels of argon gas and hydrogen gas in cryogenic pump chamber.

  19. Identification of High-Risk Plaques Destined to Cause Acute Coronary Syndrome Using Coronary Computed Tomographic Angiography and Computational Fluid Dynamics.

    Science.gov (United States)

    Lee, Joo Myung; Choi, Gilwoo; Koo, Bon-Kwon; Hwang, Doyeon; Park, Jonghanne; Zhang, Jinlong; Kim, Kyung-Jin; Tong, Yaliang; Kim, Hyun Jin; Grady, Leo; Doh, Joon-Hyung; Nam, Chang-Wook; Shin, Eun-Seok; Cho, Young-Seok; Choi, Su-Yeon; Chun, Eun Ju; Choi, Jin-Ho; Nørgaard, Bjarne L; Christiansen, Evald H; Niemen, Koen; Otake, Hiromasa; Penicka, Martin; de Bruyne, Bernard; Kubo, Takashi; Akasaka, Takashi; Narula, Jagat; Douglas, Pamela S; Taylor, Charles A; Kim, Hyo-Soo

    2018-03-14

    We investigated the utility of noninvasive hemodynamic assessment in the identification of high-risk plaques that caused subsequent acute coronary syndrome (ACS). ACS is a critical event that impacts the prognosis of patients with coronary artery disease. However, the role of hemodynamic factors in the development of ACS is not well-known. Seventy-two patients with clearly documented ACS and available coronary computed tomographic angiography (CTA) acquired between 1 month and 2 years before the development of ACS were included. In 66 culprit and 150 nonculprit lesions as a case-control design, the presence of adverse plaque characteristics (APC) was assessed and hemodynamic parameters (fractional flow reserve derived by coronary computed tomographic angiography [FFR CT ], change in FFR CT across the lesion [△FFR CT ], wall shear stress [WSS], and axial plaque stress) were analyzed using computational fluid dynamics. The best cut-off values for FFR CT , △FFR CT , WSS, and axial plaque stress were used to define the presence of adverse hemodynamic characteristics (AHC). The incremental discriminant and reclassification abilities for ACS prediction were compared among 3 models (model 1: percent diameter stenosis [%DS] and lesion length, model 2: model 1 + APC, and model 3: model 2 + AHC). The culprit lesions showed higher %DS (55.5 ± 15.4% vs. 43.1 ± 15.0%; p stress than nonculprit lesions (all p values statistic [c-index] 0.789 vs. 0.747; p = 0.014) and reclassification abilities (category-free net reclassification index 0.287; p = 0.047; relative integrated discrimination improvement 0.368; p < 0.001) than model 2. Lesions with both APC and AHC showed significantly higher risk of the culprit for subsequent ACS than those with no APC/AHC (hazard ratio: 11.75; 95% confidence interval: 2.85 to 48.51; p = 0.001) and with either APC or AHC (hazard ratio: 3.22; 95% confidence interval: 1.86 to 5.55; p < 0.001). Noninvasive hemodynamic assessment enhanced

  20. Application of the constant rate of pressure change method to improve jet pump performance

    International Nuclear Information System (INIS)

    Long, X P; Yang, X L

    2012-01-01

    This paper adopts a new method named the constant rate of pressure change (CRPC) to improve the jet pump performance. The main contribution of this method is that the diffuser generates uniform pressure gradient. The performance of the jet pump with new diffusers designed by the CRPC method, obtained by CFD methods, was compared with that of the jet pump with traditional conical diffusers. It is found that the CRPC diffuser produces a linear pressure increase indeed. The higher friction loss and the separation decrease the CRPC diffuser efficiency and then lower the pump efficiency. The pump with shorter throats has higher efficiency at small flow ratio while its efficiency is lower than the original pump at lager flow ratio and the peak efficiency of the pumps with the throat length of 5-6 Dt is higher than that of the pumps with other throat length. When the throat length is less than 4 Dt, the CRPC diffuser efficiency is higher than the conical diffuser. The CRPC method could also be used to design the nozzle and other situations needing the pressure change gradually.

  1. Hybrid lasers produced in potassium vapor by off-resonance pumping

    International Nuclear Information System (INIS)

    Clark, B.K.; Stack, C.A.; Muehsler, H.E.

    1993-01-01

    Pulsed amplified emissions are observed at or near atomic transitions cascading down from the K(6S) and K(4D 5/2 ) states, when a pulsed dye laser is tuned near the K(6S left-arrow 4 3/2,1/2 ) and the K(4D 5/2 left-arrow 4P 3/2 ) transitions. Emissions are suppressed when the pulsed dye laser is tuned to the K(4D 3/2 left-arrow 4P 5/3,3/2 ) transitions. The pulsed dye laser is used to excite molecules in a heat-pipe oven from high-bring ro-vibrational levels in the K 2 (X 1 Σ g + ) ground state to ro-vibrational levels in the K 2 (B 1 product u ) state that predissociate to K(4S) and K(4P) atoms. The transitions can be pumped when the laser is tuned sufficiently close to the atomic resonances. We discuss the non-linear mechanisms responsible for the observed emissions. Emissions cascading down from the K(4S) state were first reported by Wang et al

  2. Investigating Effect of Drug Use on Short-term Complications and Bleeding in Patients Undergoing Off-pump CABG (OPCAB

    Directory of Open Access Journals (Sweden)

    M Hadadzadeh

    2013-08-01

    Full Text Available Introduction: Opioid abuse is a major social and health problem in many parts of the world especially in Iran. There are not much information about effect of drugs (addiction on short-term complications and bleeding after CABG. This study aimed to assess the relationship between addiction with short-term complications and bleeding after CABG. Methods: This is a descriptive study in which 100 male patients who underwent off-pump CABG in Afshar hospital in yazd were followed during 3 months to investigate their short-term complications. preoperative and post-operative Hb, Plt, Pt, Ptt, bleeding and packed cells after operation were recorded. Then, collected data was analyzed by chi-square, fisher and exact test . Results: In this study, 30 patients were addicts and 70 male patients were non-addicts. All patients were males and similar in preoperative characteristics such as HTN, DM, HLP, CAD, LIMA usage and NYHA FC. Addicted patients were younger than non-addicts and most of them were cigarette smokers. Regarding medical and dietary recommendation after operation, addicted patients observed these recommendation significantly less than non-addicted patients. After operation, pulmonary, neurologic and infective complications were significantly more common in addicted patients. Conclusion: According the study results and other similar studies, drug use in patients with cardiovascular disease is noticeable. Moreover, regarding the postoperative outcomes in addicted patients, more studies needs to be conducted in this field.

  3. Single coronary artery; extremely rare coronary anomaly successfully treated surgically in young adult male.

    LENUS (Irish Health Repository)

    Shah, A R

    2010-05-01

    Single coronary artery arising from aortic root, is a rare congenital anomaly. A 30-year-old male presented with acute myocardial infarction (MI) complaining of chest pain and raised troponin levels. Emergency angiography showed no coronary lesions but both left and right coronary arteries arising from single ostium. Patient was operated electively and perioperative findings confirmed the diagnosis of single coronary artery, as left coronary artery after taking origin from right sinus of valsalva runs through the septum, before dividing into left anterior descending and circumflex branches. The single coronary ostium opened with a slit like incision over the course of left main coronary, making the size of ostium three to four times bigger than the native one. In addition left internal mammary artery was harvested and grafted to the left anterior descending branch distally. Patient made successful recovery. Four months follow up dobutamine stress echo showed no inducible ischemia.

  4. Bose-Einstein condensation in an ultra-hot gas of pumped magnons.

    Science.gov (United States)

    Serga, Alexander A; Tiberkevich, Vasil S; Sandweg, Christian W; Vasyuchka, Vitaliy I; Bozhko, Dmytro A; Chumak, Andrii V; Neumann, Timo; Obry, Björn; Melkov, Gennadii A; Slavin, Andrei N; Hillebrands, Burkard

    2014-03-11

    Bose-Einstein condensation of quasi-particles such as excitons, polaritons, magnons and photons is a fascinating quantum mechanical phenomenon. Unlike the Bose-Einstein condensation of real particles (like atoms), these processes do not require low temperatures, since the high densities of low-energy quasi-particles needed for the condensate to form can be produced via external pumping. Here we demonstrate that such a pumping can create remarkably high effective temperatures in a narrow spectral region of the lowest energy states in a magnon gas, resulting in strikingly unexpected transitional dynamics of Bose-Einstein magnon condensate: the density of the condensate increases immediately after the external magnon flow is switched off and initially decreases if it is switched on again. This behaviour finds explanation in a nonlinear 'evaporative supercooling' mechanism that couples the low-energy magnons overheated by pumping with all the other thermal magnons, removing the excess heat, and allowing Bose-Einstein condensate formation.

  5. PLACENTAL GROWTH FACTOR AND CORONARY NEOANGIOGENESIS IN CORONARY HEART DISEASE

    Directory of Open Access Journals (Sweden)

    M. V. Tulikov

    2013-01-01

    Full Text Available Neoangiogenesis in coronary heart disease is a protective reaction aimed to improve ischemic myocardial perfusion, by increasing the number and size of arterial collaterals. Placental growth factor (PlGF is one of the key peptides regulating angiogenic processes in atherosclerosis. In particular, a number of investigators have shown that injection of recombinant PlGF into the system or regional blood flow can stimulate neoangiogenesis. On the other hand, there is evidence confirming the involvement of PlGF in the progression of atherosclerosis and in the development of acute coronary syndrome. In this connection, the problem of investigating the efficiency and safety of possible use of PlGF preparations, as well as its place in the diagnosis of coronary heart disease and acute coronary syndrome remains urgent

  6. Proton pump inhibitor co-prescription with dual antiplatelet therapy among patients with acute coronary syndrome in Qatar.

    Science.gov (United States)

    Awaisu, Ahmed; Hamou, Fatima; Mekideche, Lylia; El Muabby, Nisrine; Mahfouz, Ahmed; Mohammed, Shaban; Saad, Ahmad

    2016-04-01

    There are increasing concerns about clinically significant interactions between proton pump inhibitors (PPIs) and clopidogrel, resulting in adverse cardiovascular outcomes in patients with acute coronary syndromes (ACS). However, published evidence on the prevalence and predictors of PPI use with dual antiplatelet therapy (DAPT) is scarce. This study investigated the prevalence of PPI use among patients with ACS receiving DAPT and possible predictors of co-prescribing the PPIs with the DAPT. Heart Hospital, a specialized tertiary care center in Qatar. A retrospective observational study of a prescription database was conducted. Subjects included 626 patients admitted between January and December 2012 with the diagnosis of ACS who received DAPT and discharged with or without a PPI. Univariate analysis and multivariate binary logistic regression analysis were performed to determine the predictors of PPI-DAPT co-prescription. Prevalence of PPI co-prescribing with DAPT in proportions and percentages and odd ratios for the predictors of PPI-DAPT co-prescribing. A total of 626 patients were analyzed for PPI prevalence, with 200 patients (32 %) being prescribed PPI with DAPT upon discharge. After controlling for confounders, PPI use on admission (aOR 14.5; 95 % CI 7.6-27.6, p < 0.001), nationality (aOR 3.2; 95 % CI 1.1-9.9, p = 0.041), and having a history of diabetes (aOR 0.5; 95 % CI 0.24-0.99, p = 0.046) significantly influenced PPI-DAPT co-prescribing. Users of PPI on admission compared to nonusers were about 15 times more likely to be prescribed PPI with DAPT upon discharge; likewise, having Qatari nationality increased the likelihood of co-prescribing PPI with DAPT upon discharge by three folds. Lastly, patients with a history of diabetes were 50 % less likely to be prescribed PPIs upon discharge compared to those with no history of diabetes. The rate of PPI co-prescribing with DAPT in the population studied was relatively high. The strongest predictor of PPI co

  7. A Takagi–Sugeno fuzzy power-distribution method for a prototypical advanced reactor considering pump degradation

    Directory of Open Access Journals (Sweden)

    Yue Yuan

    2017-08-01

    Full Text Available Advanced reactor designs often feature longer operating cycles between refueling and new concepts of operation beyond traditional baseload electricity production. Owing to this increased complexity, traditional proportional–integral control may not be sufficient across all potential operating regimes. The prototypical advanced reactor (PAR design features two independent reactor modules, each connected to a single dedicated steam generator that feeds a common balance of plant for electricity generation and process heat applications. In the current research, the PAR is expected to operate in a load-following manner to produce electricity to meet grid demand over a 24-hour period. Over the operational lifetime of the PAR system, primary and intermediate sodium pumps are expected to degrade in performance. The independent operation of the two reactor modules in the PAR may allow the system to continue operating under degraded pump performance by shifting the power production between reactor modules in order to meet overall load demands. This paper proposes a Takagi–Sugeno (T–S fuzzy logic-based power distribution system. Two T–S fuzzy power distribution controllers have been designed and tested. Simulation shows that the devised T–S fuzzy controllers provide improved performance over traditional controls during daily load-following operation under different levels of pump degradation.

  8. A Takagi-Sugeno fuzzy power-distribution method for a prototypical advanced reactor considering pump degradation

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Yue [Institute of Nuclear and New Energy Technology, Tsinghua University, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Beijing (China); Coble, Jamie [Dept. of Nuclear Engineering, University of Tennessee, Knoxville (United States)

    2017-08-15

    Advanced reactor designs often feature longer operating cycles between refueling and new concepts of operation beyond traditional baseload electricity production. Owing to this increased complexity, traditional proportional–integral control may not be sufficient across all potential operating regimes. The prototypical advanced reactor (PAR) design features two independent reactor modules, each connected to a single dedicated steam generator that feeds a common balance of plant for electricity generation and process heat applications. In the current research, the PAR is expected to operate in a load-following manner to produce electricity to meet grid demand over a 24-hour period. Over the operational lifetime of the PAR system, primary and intermediate sodium pumps are expected to degrade in performance. The independent operation of the two reactor modules in the PAR may allow the system to continue operating under degraded pump performance by shifting the power production between reactor modules in order to meet overall load demands. This paper proposes a Takagi–Sugeno (T–S) fuzzy logic-based power distribution system. Two T–S fuzzy power distribution controllers have been designed and tested. Simulation shows that the devised T–S fuzzy controllers provide improved performance over traditional controls during daily load-following operation under different levels of pump degradation.

  9. Bad Loans and Loan Write-Offs

    OpenAIRE

    福田, 慎一; 鯉渕, 賢

    2006-01-01

    In this paper, we investigate who bears the burden when writing off bad loans in Japan. Traditionally, Japanese main banks bore large burdens in saving their customers. We still find that some main banks bear a large burden in saving their customers. However, in most cases, main banks became very reluctant to bear large burdens when bailing out their customers. In the transition from the bank-based system to a market-based system, traditional implicit rules are collapsing dramatically. We sug...

  10. Impact of glucose intolerance on coronary calcified lesions evaluated using multislice computed tomography

    International Nuclear Information System (INIS)

    Nomura, Kyoko; Ohwaki, Kazuhiro; Yano, Eiji; Yamanouchi, Toshikazu; Kim, Gwang U.

    2007-01-01

    Metabolic syndrome has the unique concept that the common occurrence of individual disease components increases the risk of coronary artery disease (CAD). However, some studies suggest that the burden of different CAD risk factors is not equal, and focusing on the whole set of risk factors might neglect the impact of individual factors that could be useful targets for prophylactic therapies. The purpose of this study was to investigate the effect of glucose intolerance on CAD using multislice computed tomography (MSCT). Ninety-eight consecutive patients with at least one traditional CAD risk factor who visited a municipal hospital were enrolled in this study. The risk factors were impaired glucose tolerance (fasting glucose≥110 mg/dl or patients with diabetes), low high-density lipoprotein cholesterol (HDL-C, 25 kg/m 2 for men and >23 kg/m 2 for women). CAD was determined by the presence of either stenoses, non-calcified plaques or calcified lesions. The following risk factors were significantly related in univariate logistic models: glucose intolerance and coronary calcified lesions (p=0.001), and hypertriglycemia and non-calcified plaque lesions (p=0.048). Multivariate models showed that glucose intolerance was significantly associated with calcified lesions, even after adjustment for gender, age, low HDL-C, hypertriglycemia, hypertension, and obesity (p=0.018). Our results suggest that glucose intolerance might be closely related to the presence of coronary calcified lesions among traditional CAD risk factors. (author)

  11. Operation and control strategies in pre-series testing of cold circulating pumps for ITER

    International Nuclear Information System (INIS)

    Bhattacharya, R.; Vaghela, H.; Sarkar, B.; Srinivas, M.; Choukekar, K.

    2013-01-01

    Cryo-distribution system of ITER is responsible for the distribution and control of forced-flow supercritical helium for cooling of the superconducting magnets and the cryo-pumps. The requirements of cold circulating pumps (CCP) for mass flow rates and performance are much higher than presently existing and commercially available one used at 4.0 K helium. Design up-scaling with pre-series test of CCP has been proposed including test infrastructure. Operation and control strategies for the test distribution box (TDB) of test infrastructure have been developed and analyzed using steady state and dynamic process simulation to cope with the functional requirements of CCPs. Off-normal scenario with CCP inlet pressure variation is an important concern, dynamic process responses during such scenario have been evaluated to verify the operability of CCP. The paper describes process simulation to cope with the functional requirements of CCPs along with evaluation of off-normal scenario to verify the operability of CCP. (author)

  12. [Development of an automated processing method to detect coronary motion for coronary magnetic resonance angiography].

    Science.gov (United States)

    Asou, Hiroya; Imada, N; Sato, T

    2010-06-20

    On coronary MR angiography (CMRA), cardiac motions worsen the image quality. To improve the image quality, detection of cardiac especially for individual coronary motion is very important. Usually, scan delay and duration were determined manually by the operator. We developed a new evaluation method to calculate static time of individual coronary artery. At first, coronary cine MRI was taken at the level of about 3 cm below the aortic valve (80 images/R-R). Chronological change of the signals were evaluated with Fourier transformation of each pixel of the images were done. Noise reduction with subtraction process and extraction process were done. To extract higher motion such as coronary arteries, morphological filter process and labeling process were added. Using these imaging processes, individual coronary motion was extracted and individual coronary static time was calculated automatically. We compared the images with ordinary manual method and new automated method in 10 healthy volunteers. Coronary static times were calculated with our method. Calculated coronary static time was shorter than that of ordinary manual method. And scan time became about 10% longer than that of ordinary method. Image qualities were improved in our method. Our automated detection method for coronary static time with chronological Fourier transformation has a potential to improve the image quality of CMRA and easy processing.

  13. Congenital coronary-pulmonary artery fistula originating from right and left coronary artery

    Directory of Open Access Journals (Sweden)

    Ali Kemal Gür

    2013-12-01

    Full Text Available Coronary artery fistula (CAF is a rare congenital anomalywith an incidence of 1 in 50 000 live births. The fistula wasobserved at the right coronary artery in 53%, the left coronaryartery in 42% and both coronary artery in 5% of thecases. Echocardiography examination in a 46 year-oldwoman with the symptoms of chest pain, palpitation anddyspnea revealed a severe mitral valve insufficiency anda moderate to severe tricuspid valve insufficiency. A CAForiginating from the proximal part of the left anterior descendingartery (LAD and another fistula originating fromosteal part of the right coronary artery (RCA were detectedby coronary angiography. Both fistulas were draininginto the main pulmonary artery. The coronary artery fistulaclosed under cardiopulmonary by-pass. Mitral insufficiencyoriginated from the posterior leaflet was diagnosedintra-operative exploration, and thereafter it was repairedwith mitral annuloplasty including a quadrangular resectionand use of a 32 No St Jude mitral ring. Tricuspid valvewas repaired with Calangos Ring annuloplasty. Followingsix day hospital stay, the woman was discharged free ofany symptom.Key words: Dyspnea, double arteriovenous fistula, mitral and tricuspid insufficiency

  14. Dry vacuum pumps

    International Nuclear Information System (INIS)

    Sibuet, R

    2008-01-01

    For decades and for ultimate pressure below 1 mbar, oil-sealed Rotary Vane Pumps have been the most popular solution for a wide range of vacuum applications. In the late 80ies, Semiconductor Industry has initiated the development of the first dry roughing pumps. Today SC applications are only using dry pumps and dry pumping packages. Since that time, pumps manufacturers have developed dry vacuum pumps technologies in order to make them attractive for other applications. The trend to replace lubricated pumps by dry pumps is now spreading over many other market segments. For the Semiconductor Industry, it has been quite easy to understand the benefits of dry pumps, in terms of Cost of Ownership, process contamination and up-time. In this paper, Technology of Dry pumps, its application in R and D/industries, merits over conventional pumps and future growth scope will be discussed

  15. Selective coronary scintigraphy

    International Nuclear Information System (INIS)

    Gambini, D.-J.

    1975-01-01

    Isotopic techniques occupy a leading place amongst examinations practicable on coronary patients because of their reliability and the safety and simplicity of their use. The present work reviews the possible applications of selective coronary scintigraphy in pathology. After a brief discussion on scintigraphy, isotopic techniques for myocardium research, coronarography and other methods to study local myocardium perfusion the theoretical bases for the use of the exploration are studied, the techniques and methods employed are reported and the results discussed. Coronary scintigraphy consists of selective injection in the two coronary arteries previously catheterized during a coronarography, of two different populations of microspheres labelled with two physically short-lived indicators: 15μ 99m Tc-labelled serumalbumin microspheres, 10 to 15μ In-labelled siderophiline microspheres. Various studies have shown the complete harmlessness of the exploration when certain precautions are taken regarding the size and number of the spheres. The microspheres disperse into the downstream arterial territory proportionally to the number of capillaries present in the different parts of the irrigated region, and are temporarily stopped in the precapillaries. The preparation of the different images needed to interpret the Face and OAG examination for the left coronary, then for the right coronary, is carried out at the end of the coronarography and lasts about 45 minutes. It is also possible by selective injection in the aorta-coronary bridges to judge their functional condition by observation of the regions they irrigate. 56 patients of the Necker hospital cardiological clinic have been examined [fr

  16. Prediction of Hydraulic Performance of a Scaled-Down Model of SMART Reactor Coolant Pump

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Sun Guk; Park, Jin Seok; Yu, Je Yong; Lee, Won Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-08-15

    An analysis was conducted to predict the hydraulic performance of a reactor coolant pump (RCP) of SMART at the off-design as well as design points. In order to reduce the analysis time efficiently, a single passage containing an impeller and a diffuser was considered as the computational domain. A stage scheme was used to perform a circumferential averaging of the flux on the impeller-diffuser interface. The pressure difference between the inlet and outlet of the pump was determined and was used to compute the head, efficiency, and break horse power (BHP) of a scaled-down model under conditions of steady-state incompressible flow. The predicted curves of the hydraulic performance of an RCP were similar to the typical characteristic curves of a conventional mixed-flow pump. The complex internal fluid flow of a pump, including the internal recirculation loss due to reverse flow, was observed at a low flow rate.

  17. Physiologic assessment of coronary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, N.C.; Beauvais, J. (Creighton Univ., Omaha, NE (USA))

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery.

  18. Physiologic assessment of coronary artery fistula

    International Nuclear Information System (INIS)

    Gupta, N.C.; Beauvais, J.

    1991-01-01

    Coronary artery fistula is an uncommon clinical entity. The most common coronary artery fistula is from the right coronary artery to the right side of the heart, and it is less frequent to the pulmonary artery. The effect of a coronary artery fistula may be physiologically significant because of the steal phenomenon resulting in coronary ischemia. Based on published reports, it is recommended that patients with congenital coronary artery fistulas be considered candidates for elective surgical correction to prevent complications including development of congestive heart failure, angina, subacute bacterial endocarditis, myocardial infarction, and coronary aneurysm formation with rupture or embolization. A patient is presented in whom treadmill-exercise thallium imaging was effective in determining the degree of coronary steal from a coronary artery fistula, leading to successful corrective surgery

  19. Coronary plaque quantification and fractional flow reserve by coronary computed tomography angiography identify ischaemia-causing lesions

    DEFF Research Database (Denmark)

    Gaur, Sara; Øvrehus, Kristian Altern; Dey, Damini

    2016-01-01

    AIMS: Coronary plaque characteristics are associated with ischaemia. Differences in plaque volumes and composition may explain the discordance between coronary stenosis severity and ischaemia. We evaluated the association between coronary stenosis severity, plaque characteristics, coronary computed...... tomography angiography (CTA)-derived fractional flow reserve (FFRCT), and lesion-specific ischaemia identified by FFR in a substudy of the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). METHODS AND RESULTS: Coronary CTA stenosis, plaque volumes, FFRCT, and FFR were assessed...

  20. Dual light-activated microfluidic pumps based on an optopiezoelectric composite

    International Nuclear Information System (INIS)

    Wang, Hsin-Hu; Lee, Chih-Kung; Hsu, Yu-Hsiang; Wu, Ting-Jui; Cheng, I-Chun; Lin, Shih-Jue; Gu, Jen-Tau

    2017-01-01

    In this paper, a new type of microfluidic pump that can be activated and controlled by a masked light source is presented. The actuation of this micropump is based on an optopiezoelectric composite. This composite is constructed by having one of the electrodes of a piezoelectric PVDF (polyvinylidene fluoride) polymer replaced by a layer of TiOPc (titanyl phthalocyanine) photoconductive coating and an ITO (indium-tin-oxide) transparent electrode. This layer of photoconductive electrode provides the capability to activate multiple locations of this optopiezoelectric composite independently using a masked light source and a single voltage source. To verify the feasibility of this concept, dual light-activated microfluidic pumps based on this optopiezoelectric composite are implemented and studied. Experimental results verify that two microfluidic pumps can be created by one optopiezoelectric composite and that each pump can be optically turned on and off independently or be turned on simultaneously. These results suggest that integrating an optopiezoelectric composite into a lab-on-a-chip system can reduce the size and the number of driving units significantly, since every operation can be done optically and only one driving source is needed. The equivalent circuit, design, and implementation of dual light-activated optopiezoelectric micropumps are discussed in this paper. (paper)