WorldWideScience

Sample records for traditional measurement techniques

  1. Are we really measuring what we say we're measuring? Using video techniques to supplement traditional construct validation procedures.

    Science.gov (United States)

    Podsakoff, Nathan P; Podsakoff, Philip M; Mackenzie, Scott B; Klinger, Ryan L

    2013-01-01

    Several researchers have persuasively argued that the most important evidence to consider when assessing construct validity is whether variations in the construct of interest cause corresponding variations in the measures of the focal construct. Unfortunately, the literature provides little practical guidance on how researchers can go about testing this. Therefore, the purpose of this article is to describe how researchers can use video techniques to test whether their scales measure what they purport to measure. First, we discuss how researchers can develop valid manipulations of the focal construct that they hope to measure. Next, we explain how to design a study to use this manipulation to test the validity of the scale. Finally, comparing and contrasting traditional and contemporary perspectives on validation, we discuss the advantages and limitations of video-based validation procedures. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  2. Application of microdialysis technique in the traditional chinese medicine

    DEFF Research Database (Denmark)

    Zhang, Shaomin; Zeng, Xianghui; Xu, Xiaohong

    2005-01-01

    The concentration of extracellular neurotransmitters can be dynamically measured by in vivo microdialysis. This technique can apply to quantitatively evaluating the beneficial effects of Traditional Chinese Medicine (TCM). In the present study, the protective effects of Puerarin (Pur) on cerebral...

  3. Wind Gust Measurement Techniques—From Traditional Anemometry to New Possibilities

    Directory of Open Access Journals (Sweden)

    Irene Suomi

    2018-04-01

    Full Text Available Information on wind gusts is needed for assessment of wind-induced damage and risks to safety. The measurement of wind gust speed requires a high temporal resolution of the anemometer system, because the gust is defined as a short-duration (seconds maximum of the fluctuating wind speed. Until the digitalization of wind measurements in the 1990s, the wind gust measurements suffered from limited recording and data processing resources. Therefore, the majority of continuous wind gust records date back at most only by 30 years. Although the response characteristics of anemometer systems are good enough today, the traditional measurement techniques at weather stations based on cup and sonic anemometers are limited to heights and regions where the supporting structures can reach. Therefore, existing measurements are mainly concentrated over densely-populated land areas, whereas from remote locations, such as the marine Arctic, wind gust information is available only from sparse coastal locations. Recent developments of wind gust measurement techniques based on turbulence measurements from research aircraft and from Doppler lidar can potentially provide new information from heights and locations unreachable by traditional measurement techniques. Moreover, fast-developing measurement methods based on Unmanned Aircraft Systems (UASs may add to better coverage of wind gust measurements in the future. In this paper, we provide an overview of the history and the current status of anemometry from the perspective of wind gusts. Furthermore, a discussion on the potential future directions of wind gust measurement techniques is provided.

  4. The patient relationship and therapeutic techniques of the South Sotho traditional healer.

    Science.gov (United States)

    Pinkoane, M G; Greeff, M; Williams, M J S

    2005-11-01

    Until 1996 the practice of traditional healers was outlawed in South Africa and not afforded a legal position in the community of health care providers. In 1978 the World Health Organization (WHO) identified traditional healers as those people forming an essential core of primary health care workers for rural people in the Third World Countries. However in 1994 the new South African government identified traditional healers as forming an essential element of primary health care workers. It is estimated that 80% of the black population uses traditional medicine because it is deeply rooted in their culture, which is linked to their religion. The traditional healer shares with the patient a world view which is completely alien to biomedical personnel. Therapeutic techniques typically used in traditional healing conflict with the therapeutic techniques used in biomedicine. The patients' perceptions of traditional healing, their needs and expectations, may be the driving force behind their continuous persistence to consult a traditional healer, even after these patients may have sought the therapeutic techniques of biomedical personnel. The operation of both systems in the same society creates a problem to both providers and recipients of health care. Confusion then arises and the consumer consequently chooses the services closer to her. The researcher aimed at investigating the characteristics of the relationship between the traditional healers and the patients, explored the therapeutic techniques that are used in the South Sotho traditional healing process, and investigated the views of both the traditional healers and the patients about the South -Sotho traditional healing process, to facilitate incorporation of the traditional healers in the National Health Care Delivery System. A qualitative research design was followed. Participants were identified by means of a non-probable, purposive voluntary sample. Data was collected by means of a video camera and semi

  5. Line identification studies using traditional techniques and wavelength coincidence statistics

    International Nuclear Information System (INIS)

    Cowley, C.R.; Adelman, S.J.

    1990-01-01

    Traditional line identification techniques result in the assignment of individual lines to an atomic or ionic species. These methods may be supplemented by wavelength coincidence statistics (WCS). The strength and weakness of these methods are discussed using spectra of a number of normal and peculiar B and A stars that have been studied independently by both methods. The present results support the overall findings of some earlier studies. WCS would be most useful in a first survey, before traditional methods have been applied. WCS can quickly make a global search for all species and in this way may enable identifications of an unexpected spectrum that could easily be omitted entirely from a traditional study. This is illustrated by O I. WCS is a subject to well known weakness of any statistical technique, for example, a predictable number of spurious results are to be expected. The danger of small number statistics are illustrated. WCS is at its best relative to traditional methods in finding a line-rich atomic species that is only weakly present in a complicated stellar spectrum

  6. Exploring Traditional Glass Bead Making Techniques in Jewellery ...

    African Journals Online (AJOL)

    Exploring traditional glass bead making techniques in jewellery in some prominent areas in Ghana is a means to exposing the area for metal and ceramic artists and other related fields of discipline such as aesthetics and criticism to complement their form of ... Keywords: livelihood, vitreous, glass bottles, furnace, threading ...

  7. Characterization of Natural Dyes and Traditional Korean Silk Fabric by Surface Analytical Techniques

    Directory of Open Access Journals (Sweden)

    Yeonhee Lee

    2013-05-01

    Full Text Available Time-of-flight secondary ion mass spectrometry (TOF-SIMS and X-ray photoelectron spectroscopy (XPS are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric.

  8. Characterization of Natural Dyes and Traditional Korean Silk Fabric by Surface Analytical Techniques

    Science.gov (United States)

    Lee, Jihye; Kang, Min Hwa; Lee, Kang-Bong; Lee, Yeonhee

    2013-01-01

    Time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS) are well established surface techniques that provide both elemental and organic information from several monolayers of a sample surface, while also allowing depth profiling or image mapping to be carried out. The static TOF-SIMS with improved performances has expanded the application of TOF-SIMS to the study of a variety of organic, polymeric and biological materials. In this work, TOF-SIMS, XPS and Fourier Transform Infrared (FTIR) measurements were used to characterize commercial natural dyes and traditional silk fabric dyed with plant extracts dyes avoiding the time-consuming and destructive extraction procedures necessary for the spectrophotometric and chromatographic methods previously used. Silk textiles dyed with plant extracts were then analyzed for chemical and functional group identification of their dye components and mordants. TOF-SIMS spectra for the dyed silk fabric showed element ions from metallic mordants, specific fragment ions and molecular ions from plant-extracted dyes. The results of TOF-SIMS, XPS and FTIR are very useful as a reference database for comparison with data about traditional Korean silk fabric and to provide an understanding of traditional dyeing materials. Therefore, this study shows that surface techniques are useful for micro-destructive analysis of plant-extracted dyes and Korean dyed silk fabric. PMID:28809257

  9. Timber Elements: Traditional and Modern Strengthening Techniques

    Directory of Open Access Journals (Sweden)

    Raluca Hohan

    2010-01-01

    Full Text Available The main idea of this paper is to analyse the means for the rehabilitation of our cultural heritage timber structures. Several methods together with their application techniques are described, and also, the reasons for what these strengthening operations become imminent at a point. First of all, the necessity of the timber structural elements strengthening is explained through a short presentation of the factors which are degrading the material. Then, certain precautions and strengthening procedures are presented, all involving the usage of traditional materials like wood, metal, or concrete, and of modern materials like fiber reinforced polymeric composite.

  10. An automated technique to identify potential inappropriate traditional Chinese medicine (TCM) prescriptions.

    Science.gov (United States)

    Yang, Hsuan-Chia; Iqbal, Usman; Nguyen, Phung Anh; Lin, Shen-Hsien; Huang, Chih-Wei; Jian, Wen-Shan; Li, Yu-Chuan

    2016-04-01

    Medication errors such as potential inappropriate prescriptions would induce serious adverse drug events to patients. Information technology has the ability to prevent medication errors; however, the pharmacology of traditional Chinese medicine (TCM) is not as clear as in western medicine. The aim of this study was to apply the appropriateness of prescription (AOP) model to identify potential inappropriate TCM prescriptions. We used the association rule of mining techniques to analyze 14.5 million prescriptions from the Taiwan National Health Insurance Research Database. The disease and TCM (DTCM) and traditional Chinese medicine-traditional Chinese medicine (TCMM) associations are computed by their co-occurrence, and the associations' strength was measured as Q-values, which often referred to as interestingness or life values. By considering the number of Q-values, the AOP model was applied to identify the inappropriate prescriptions. Afterwards, three traditional Chinese physicians evaluated 1920 prescriptions and validated the detected outcomes from the AOP model. Out of 1920 prescriptions, 97.1% of positive predictive value and 19.5% of negative predictive value were shown by the system as compared with those by experts. The sensitivity analysis indicated that the negative predictive value could improve up to 27.5% when the model's threshold changed to 0.4. We successfully applied the AOP model to automatically identify potential inappropriate TCM prescriptions. This model could be a potential TCM clinical decision support system in order to improve drug safety and quality of care. Copyright © 2016 John Wiley & Sons, Ltd.

  11. A multi-slice sliding cell technique for diffusion measurements in liquid metals

    Science.gov (United States)

    Zhong, Langxiang; Hu, Jinliang; Geng, Yongliang; Zhu, Chunao; Zhang, Bo

    2017-09-01

    The long capillary and shear-cell techniques are traditionally used for diffusion measurements in liquid metals. Inspired by the idea of the shear-cell method, we have built a multi-slice sliding cell device for inter-diffusion measurements in liquid metals. The device is designed based on a linear sliding movement rather than a rotational shearing as used in the traditional shear-cell method. Compared with the normal shear-cell method, the present device is a more compact setup thus easier to handle. Also, it is expected to be easier to monitor with X-rays or neutrons if used in in situ experiments. A series of benchmark time-dependent diffusion experiments in Al-Cu melts carried out with the present technique reveal that accurate diffusion constants can be achieved only after a sufficient time. For short annealing times, the initial shearing process causing convective flow dominates the measurement and leads to an increase of the measured diffusion coefficient by a factor three. The diffusion data obtained for Al-Cu liquids are consistent with the most accurate data measured by the in situ X-ray radiography method under well controlled conditions of no temperature gradient or other perturbation. High accuracy and easy handling as well as superior adaptability make the present technique suitable for diffusion studies in liquid metals.

  12. A New Measure of Traditional Values Across Cultures: China and Russia Compared

    Directory of Open Access Journals (Sweden)

    Robert J. Taormina

    2016-10-01

    Full Text Available A new measure of adherence to traditional values was created with the objective of facilitating research within and across cultures and nations. The measure was tested in China (N = 321 and Russia (N = 314 and factor analysis of the data revealed two subscales named Personal Traditional Values (10 items and Public Traditional Values (6 items. Empirical psychometric testing of the overall 16-item measure and the two subscales strongly supported the validity and reliability of all three measures. Means comparisons conducted to assess how well the measures could be used for cross-cultural comparisons revealed the Russians somewhat more than the Chinese living by traditional values overall, both nations about equal on living according to traditional values in their personal lives, and the Russians significantly more inclined to abide by traditional values in public. Also tested were several social and psychological variables as theoretical predictors of living by traditional values, and Life Satisfaction was tested as a possible correlate of living according to traditional values. Regression analyses on the combined data confirmed that Family Emotional Support, Conscientiousness, Collectivism, and Age were all significant positive predictors of living by traditional values. Additional regressions also found some unique predictors for each nation. These findings and the results of the parametric tests support the use of the new scales for measuring traditional values both within and across cultures.

  13. Comparison of Traditional and Innovative Techniques to Solve Technical Challenges

    Science.gov (United States)

    Perchonok, Michele

    2011-01-01

    This slide presentation reviews the use of traditional and innovative techniques to solve technical challenges in food storage technology. The planning for a mission to Mars is underway, and the food storage technology improvements requires that improvements be made. This new technology is required, because current food storage technology is inadequate,refrigerators or freezers are not available for food preservation, and that a shelf life of 5 years is expected. A 10 year effort to improve food packaging technology has not enhanced significantly food packaging capabilities. Two innovation techniques were attempted InnoCentive and Yet2.com and have provided good results, and are still under due diligence for solver verification.

  14. Pulse holographic measurement techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  15. Comparison of a new hydro-surgical technique to traditional methods for the preparation of full-thickness skin grafts from canine cadaveric skin and report of a single clinical case.

    Science.gov (United States)

    Townsend, F I; Ralphs, S C; Coronado, G; Sweet, D C; Ward, J; Bloch, C P

    2012-01-01

    To compare the hydro-surgical technique to traditional techniques for removal of subcutaneous tissue in the preparation of full-thickness skin grafts. Ex vivo experimental study and a single clinical case report. Four canine cadavers and a single clinical case. Four sections of skin were harvested from the lateral flank of recently euthanatized dogs. Traditional preparation methods used included both a blade or scissors technique, each of which were compared to the hydro-surgical technique individually. Preparation methods were compared based on length of time for removal of the subcutaneous tissue from the graft, histologic grading, and measurable thickness as compared to an untreated sample. The hydro-surgical technique had the shortest skin graft preparation time as compared to traditional techniques (p = 0.002). There was no significant difference in the histological grading or measurable subcutaneous thickness between skin specimens. The hydro-surgical technique provides a rapid, effective debridement of subcutaneous tissue in the preparation of full-thickness skin grafts. There were not any significant changes in histological grade and subcutaneous tissue remaining among all treatment types. Additionally the hydro-surgical technique was successfully used to prepare a full-thickness meshed free skin graft in the reconstruction of a traumatic medial tarsal wound in a dog.

  16. A study for high accuracy measurement of residual stress by deep hole drilling technique

    Science.gov (United States)

    Kitano, Houichi; Okano, Shigetaka; Mochizuki, Masahito

    2012-08-01

    The deep hole drilling technique (DHD) received much attention in recent years as a method for measuring through-thickness residual stresses. However, some accuracy problems occur when residual stress evaluation is performed by the DHD technique. One of the reasons is that the traditional DHD evaluation formula applies to the plane stress condition. The second is that the effects of the plastic deformation produced in the drilling process and the deformation produced in the trepanning process are ignored. In this study, a modified evaluation formula, which is applied to the plane strain condition, is proposed. In addition, a new procedure is proposed which can consider the effects of the deformation produced in the DHD process by investigating the effects in detail by finite element (FE) analysis. Then, the evaluation results obtained by the new procedure are compared with that obtained by traditional DHD procedure by FE analysis. As a result, the new procedure evaluates the residual stress fields better than the traditional DHD procedure when the measuring object is thick enough that the stress condition can be assumed as the plane strain condition as in the model used in this study.

  17. EDITORIAL: Measurement techniques for multiphase flows Measurement techniques for multiphase flows

    Science.gov (United States)

    Okamoto, Koji; Murai, Yuichi

    2009-11-01

    Research on multiphase flows is very important for industrial applications, including power stations, vehicles, engines, food processing and so on. Multiphase flows originally have nonlinear features because of multiphase systems. The interaction between the phases plays a very interesting role in the flows. The nonlinear interaction causes the multiphase flows to be very complicated. Therefore techniques for measuring multiphase flows are very useful in helping to understand the nonlinear phenomena. The state-of-the-art measurement techniques were presented and discussed at the sixth International Symposium on Measurement Techniques for Multiphase Flows (ISMTMF2008) held in Okinawa, Japan, on 15-17 December 2008. This special feature of Measurement Science and Technology includes selected papers from ISMTMF2008. Okinawa has a long history as the Ryukyus Kingdom. China, Japan and many western Pacific countries have had cultural and economic exchanges through Okinawa for over 1000 years. Much technical and scientific information was exchanged at the symposium in Okinawa. The proceedings of ISMTMF2008 apart from these special featured papers were published in Journal of Physics: Conference Series vol. 147 (2009). We would like to express special thanks to all the contributors to the symposium and this special feature. This special feature will be a milestone in measurement techniques for multiphase flows.

  18. Traditional Vs. Contemporary Managerial/Cost Accounting Techniques Differences Between Opinions Of Educators And Practitioners

    OpenAIRE

    M. A. Ekbatani; M. A. Sangeladji

    2011-01-01

    From the mid 1980s, the start of new movements in the field of managerial/cost accounting, a gap has emerged between the opinions of academia and practitioners regarding the degree of usefulness of managerial/cost accounting techniques. It is believed that practitioners generally prefer managerial/cost accounting techniques which are simple, practical and economically applicable. On the other hand, many authors and academia believe that the traditional managerial/cost accounting techniques ar...

  19. Bullying prevalence across contexts: a meta-analysis measuring cyber and traditional bullying.

    Science.gov (United States)

    Modecki, Kathryn L; Minchin, Jeannie; Harbaugh, Allen G; Guerra, Nancy G; Runions, Kevin C

    2014-11-01

    Bullying involvement in any form can have lasting physical and emotional consequences for adolescents. For programs and policies to best safeguard youth, it is important to understand prevalence of bullying across cyber and traditional contexts. We conducted a thorough review of the literature and identified 80 studies that reported corresponding prevalence rates for cyber and traditional bullying and/or aggression in adolescents. Weighted mean effect sizes were calculated, and measurement features were entered as moderators to explain variation in prevalence rates and in traditional-cyber correlations within the sample of studies. Prevalence rates for cyber bullying were lower than for traditional bullying, and cyber and traditional bullying were highly correlated. A number of measurement features moderated variability in bullying prevalence; whereas a focus on traditional relational aggression increased correlations between cyber and traditional aggressions. In our meta-analytic review, traditional bullying was twice as common as cyber bullying. Cyber and traditional bullying were also highly correlated, suggesting that polyaggression involvement should be a primary target for interventions and policy. Results of moderation analyses highlight the need for greater consensus in measurement approaches for both cyber and traditional bullying. Copyright © 2014 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  20. The attribute measurement technique

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Langner, Diana; Smith, Morag; Thron, Jonathan; Razinkov, Sergey; Livke, Alexander

    2010-01-01

    Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. An information barrier (IB) is included in the measurement system to protect the potentially classified information while allowing sufficient information transfer to occur for the monitoring party to gain confidence that the material being measured is consistent with the host's declarations, concerning that material. The attribute measurement technique incorporates an IB and addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The attribute measurement technique has been implemented in the AVNG, an attribute measuring system described in other presentations at this conference. In this presentation, we will discuss four techniques used in the AVNG: (1) the 1B, (2) the attribute measurement technique, (3) the use of open and secure modes to increase confidence in the displayed results, and (4) the joint design as a method for addressing both host and monitor needs.

  1. Advanced in-flight measurement techniques

    CERN Document Server

    Lawson, Nicholas; Jentink, Henk; Kompenhans, Jürgen

    2013-01-01

    The book presents a synopsis of the main results achieved during the 3 year EU-project "Advanced Inflight Measurement Techniques (AIM)" which applied advanced image based measurement techniques to industrial flight testing. The book is intended to be not only an overview on the AIM activities but also a guide on the application of advanced optical measurement techniques for future flight testing. Furthermore it is a useful guide for engineers in the field of experimental methods and flight testing who face the challenge of a future requirement for the development of highly accurate non-intrusive in-flight measurement techniques.

  2. Learning from tradition. Construction techniques and repair of historical buildings in the area of Brescia: some examples

    Directory of Open Access Journals (Sweden)

    Barbara Scala

    2016-06-01

    The essay focuses on the area of Brescia where, in spite of significant transformations over time of buildings and territory, many examples of traditional architecture still exist. The aim of the paper is also to suggest, by presenting some case studies, a strategy for conservation which proposes a dialogue between traditional methods, technological innovations and economic sustainability of interventions. Keywords: Traditional architecture, Brescia, Sustainability, Construction techniques, Protection

  3. The Galileo System of Measurement: Preliminary Evidence for Precision, Stability, and Equivalance to Traditional Measures

    Science.gov (United States)

    Gillham, James; Woelfel, Joseph

    1977-01-01

    Describes the Galileo system of measurement operations including reliability and validity data. Illustrations of some of the relations between Galileo measures and traditional procedures are provided. (MH)

  4. Cross-National Prevalence of Traditional Bullying, Traditional Victimization, Cyberbullying and Cyber-Victimization: Comparing Single-Item and Multiple-Item Approaches of Measurement

    Science.gov (United States)

    Yanagida, Takuya; Gradinger, Petra; Strohmeier, Dagmar; Solomontos-Kountouri, Olga; Trip, Simona; Bora, Carmen

    2016-01-01

    Many large-scale cross-national studies rely on a single-item measurement when comparing prevalence rates of traditional bullying, traditional victimization, cyberbullying, and cyber-victimization between countries. However, the reliability and validity of single-item measurement approaches are highly problematic and might be biased. Data from…

  5. Effectiveness assessment of soil conservation measures in reducing soil erosion in Baiquan County of Northeastern China by using (137)Cs techniques.

    Science.gov (United States)

    Zhang, Qing-Wen; Li, Yong

    2014-05-01

    Accelerated soil erosion is considered as a major land degradation process resulting in increased sediment production and sediment-associated nutrient inputs to the rivers. Over the last decade, several soil conservation programs for erosion control have been conducted throughout Northeastern China. Reliable information on soil erosion rates is an essential prerequisite to assess the effectiveness of soil conservation measures. A study was carried out in Baiquan County of Northeastern China to assess the effectiveness of soil conservation measures in reducing soil erosion using the (137)Cs tracer technique and related techniques. This study reports the use of (137)Cs measurements to quantify medium-term soil erosion rates in traditional slope farmland, contour cropping farmland and terrace farmland in the Dingjiagou catchment and the Xingsheng catchment of Baiquan County. The (137)Cs reference inventory of 2532 ± 670 Bq m(-2) was determined. Based on the principle of the (137)Cs tracer technique, soil erosion rates were estimated. The results showed that severe erosion on traditional slope farmland is the dominant soil erosion process in the area. The terrace measure reduced soil erosion rates by 16% for the entire slope. Typical net soil erosion rates are estimated to be 28.97 Mg per hectare per year for traditional slope farmland and 25.04 Mg per hectare per year for terrace farmland in the Dingjiagou catchment. In contrast to traditional slope farmland with a soil erosion rate of 34.65 Mg per hectare per year, contour cultivation reduced the soil erosion rate by 53% resulting in a soil erosion rate of 22.58 Mg per hectare per year in the Xingsheng catchment. These results indicated that soil losses can be controlled by changing tillage practices from the traditional slope farmland cultivation to the terrace or contour cultivation.

  6. Algorithm for polarimetry data inversion, consistent with other measuring techniques in tokamak plasma

    International Nuclear Information System (INIS)

    Kravtsov, Y.A.; Kravtsov, Y.A.; Chrzanowski, J.; Mazon, D.

    2011-01-01

    New procedure for plasma polarimetry data inversion is suggested, which fits two parameter knowledge-based plasma model to the measured parameters (azimuthal and ellipticity angles) of the polarization ellipse. The knowledge-based model is supposed to use the magnetic field and electron density profiles, obtained from magnetic measurements and LIDAR data on the Thomson scattering. In distinction to traditional polarimetry, polarization evolution along the ray is determined on the basis of angular variables technique (AVT). The paper contains a few examples of numerical solutions of these equations, which are applicable in conditions, when Faraday and Cotton-Mouton effects are simultaneously strong. (authors)

  7. Magnetic field measurements and mapping techniques

    CERN Multimedia

    CERN. Geneva

    2003-01-01

    These lectures will present an overview of the most common techniques used for the measurement of magnetic field in accelerator magnets. The formalism for a harmonic description of the magnetic field will be presented, including a discussion of harmonics allowed under various types of symmetries in the magnet. The harmonic coil technique for measurement of field harmonics will be covered in depth. Using examples from recent projects, magnetic measurements will be shown to be a powerful tool for monitoring magnet production. Measurements of magnetic axis using extensions of the harmonic coil technique, as well as other techniques, such as the colloidal cell and stretched wire, will be covered. Topics of interest in superconducting magnets, such as time decay and snapback, requiring relatively fast measurements of the harmonics, will also be described.

  8. Radioisotope Sample Measurement Techniques in Medicine and Biology. Proceedings of the Symposium on Radioisotope Sample Measurement Techniques

    International Nuclear Information System (INIS)

    1965-01-01

    The medical and biological applications of radioisotopes depend on two basically different types of measurements, those on living subjects in vivo and those on samples in vitro. The International Atomic Energy Agency has in the past held several meetings on in vivo measurement techniques, notably whole-body counting and radioisotope scanning. The present volume contains the Proceedings of the first Symposium the Agency has organized to discuss the various aspects of techniques for sample measurement in vitro. The range of these sample measurement techniques is very wide. The sample may weigh a few milligrams or several hundred grams, and may be in the gaseous, liquid or solid state. Its radioactive content may consist of a single, known radioisotope or several unknown ones. The concentration of radioactivity may be low, medium or high. The measurements may be made manually or automatically and any one of the many radiation detectors now available may be used. The 53 papers presented at the Symposium illustrate the great variety of methods now in use for radioactive- sample measurements. The first topic discussed is gamma-ray spectrometry, which finds an increasing number of applications in sample measurements. Other sections of the Proceedings deal with: the use of computers in gamma-ray spectrometry and multiple tracer techniques; recent developments in activation analysis where both gamma-ray spectrometry and computing techniques are applied; thin-layer and paper radio chromatographic techniques for use with low energy beta-ray emitters; various aspects of liquid scintillation counting techniques in the measurement of alpha- and beta-ray emitters, including chemical and colour quenching; autoradiographic techniques; calibration of equipment; and standardization of radioisotopes. Finally, some applications of solid-state detectors are presented; this section may be regarded as a preview of important future developments. The meeting was attended by 203 participants

  9. Efficacy of proprioceptive neuromuscular facilitation techniques versus traditional prosthetic training for improving ambulatory function in transtibial amputees

    OpenAIRE

    Pallavi Sahay, MPT; Santosh Kr. Prasad, MSc; Shahnawaz Anwer, MPT; P.K. Lenka, PhD; Ratnesh Kumar, MS

    2014-01-01

    The objective of this randomized controlled trial was to evaluate the efficacy of proprioceptive neuromuscular facilitation (PNF) techniques in comparison to traditional prosthetic training (TPT) in improving ambulatory function in transtibial amputees. Thirty study participants (19 men and 11 women) with unilateral transtibial amputation participated in the study. They were randomly allocated to either the traditional training group (i.e., TPT) (n = 15) or the PNF training group (n = 15). Th...

  10. RNA interference: a promising technique for the improvement of traditional crops.

    Science.gov (United States)

    Katoch, Rajan; Thakur, Neelam

    2013-03-01

    RNA interference (RNAi) is a homology-dependent gene-silencing technology that involves double-stranded RNA directed against a target gene. This technique has emerged as powerful tool in understanding the functions of a number of genes in recent years. For the improvement in the nutritional status of the plants and reduction in the level of antinutrients, the conventional breeding methods were not completely successful in achieving the tissue-specific regulation of some genes. RNAi has shown successful results in a number of plant species for nutritional improvement, change in morphology and alteration in metabolite synthesis. This technology has been applied mostly in genetic engineering of important crop plants, and till date there are no reports of its application for the improvement of traditional/underutilized crops. In this study, we discuss current knowledge of RNAi function and concept and strategies for the improvement of traditional crops. Practical application. Although RNAi has been extensively used for the improvement of popular crops, no attention has been given for the use of this technology for the improvement of underutilized crops. This study describes the importance of use of this technology for the improvement of underutilized crops.

  11. A review on creatinine measurement techniques.

    Science.gov (United States)

    Mohabbati-Kalejahi, Elham; Azimirad, Vahid; Bahrami, Manouchehr; Ganbari, Ahmad

    2012-08-15

    This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L(-1) belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. 4. Measuring technique

    International Nuclear Information System (INIS)

    2006-01-01

    It is noted that in nuclear medicine a most widely the scintillation detectors are applying. Action of these detectors is based on registration of light flares in visible and ultraviolet field arising in scintillator under ionizing radiation action. In the chapter following subchapters are included: gamma-spectrometer and gamma radiation detectors; counter of whole body; measuring of accumulated activity (uptake measurements); scanner; scintillation chamber; single-photon emission computed tomography; positron emission computed tomography; magnet resonance tomography; computer technique, images making

  13. Comparative Accuracy of Facial Models Fabricated Using Traditional and 3D Imaging Techniques.

    Science.gov (United States)

    Lincoln, Ketu P; Sun, Albert Y T; Prihoda, Thomas J; Sutton, Alan J

    2016-04-01

    The purpose of this investigation was to compare the accuracy of facial models fabricated using facial moulage impression methods to the three-dimensional printed (3DP) fabrication methods using soft tissue images obtained from cone beam computed tomography (CBCT) and 3D stereophotogrammetry (3D-SPG) scans. A reference phantom model was fabricated using a 3D-SPG image of a human control form with ten fiducial markers placed on common anthropometric landmarks. This image was converted into the investigation control phantom model (CPM) using 3DP methods. The CPM was attached to a camera tripod for ease of image capture. Three CBCT and three 3D-SPG images of the CPM were captured. The DICOM and STL files from the three 3dMD and three CBCT were imported to the 3DP, and six testing models were made. Reversible hydrocolloid and dental stone were used to make three facial moulages of the CPM, and the impressions/casts were poured in type IV gypsum dental stone. A coordinate measuring machine (CMM) was used to measure the distances between each of the ten fiducial markers. Each measurement was made using one point as a static reference to the other nine points. The same measuring procedures were accomplished on all specimens. All measurements were compared between specimens and the control. The data were analyzed using ANOVA and Tukey pairwise comparison of the raters, methods, and fiducial markers. The ANOVA multiple comparisons showed significant difference among the three methods (p 3D-SPG showed statistical difference in comparison to the models fabricated using the traditional method of facial moulage and 3DP models fabricated from CBCT imaging. 3DP models fabricated using 3D-SPG were less accurate than the CPM and models fabricated using facial moulage and CBCT imaging techniques. © 2015 by the American College of Prosthodontists.

  14. Field test comparison of an autocorrelation technique for determining grain size using a digital 'beachball' camera versus traditional methods

    Science.gov (United States)

    Barnard, P.L.; Rubin, D.M.; Harney, J.; Mustain, N.

    2007-01-01

    This extensive field test of an autocorrelation technique for determining grain size from digital images was conducted using a digital bed-sediment camera, or 'beachball' camera. Using 205 sediment samples and >1200 images from a variety of beaches on the west coast of the US, grain size ranging from sand to granules was measured from field samples using both the autocorrelation technique developed by Rubin [Rubin, D.M., 2004. A simple autocorrelation algorithm for determining grain size from digital images of sediment. Journal of Sedimentary Research, 74(1): 160-165.] and traditional methods (i.e. settling tube analysis, sieving, and point counts). To test the accuracy of the digital-image grain size algorithm, we compared results with manual point counts of an extensive image data set in the Santa Barbara littoral cell. Grain sizes calculated using the autocorrelation algorithm were highly correlated with the point counts of the same images (r2 = 0.93; n = 79) and had an error of only 1%. Comparisons of calculated grain sizes and grain sizes measured from grab samples demonstrated that the autocorrelation technique works well on high-energy dissipative beaches with well-sorted sediment such as in the Pacific Northwest (r2 ??? 0.92; n = 115). On less dissipative, more poorly sorted beaches such as Ocean Beach in San Francisco, results were not as good (r2 ??? 0.70; n = 67; within 3% accuracy). Because the algorithm works well compared with point counts of the same image, the poorer correlation with grab samples must be a result of actual spatial and vertical variability of sediment in the field; closer agreement between grain size in the images and grain size of grab samples can be achieved by increasing the sampling volume of the images (taking more images, distributed over a volume comparable to that of a grab sample). In all field tests the autocorrelation method was able to predict the mean and median grain size with ???96% accuracy, which is more than

  15. A simple technique for measuring buoyant weight increment of entire, transplanted coral colonies in the field.

    Science.gov (United States)

    Herler, Jürgen; Dirnwöber, Markus

    2011-10-31

    Estimating the impacts of global and local threats on coral reefs requires monitoring reef health and measuring coral growth and calcification rates at different time scales. This has traditionally been mostly performed in short-term experimental studies in which coral fragments were grown in the laboratory or in the field but measured ex situ. Practical techniques in which growth and measurements are performed over the long term in situ are rare. Apart from photographic approaches, weight increment measurements have also been applied. Past buoyant weight measurements under water involved a complicated and little-used apparatus. We introduce a new method that combines previous field and laboratory techniques to measure the buoyant weight of entire, transplanted corals under water. This method uses an electronic balance fitted into an acrylic glass underwater housing and placed atop of an acrylic glass cube. Within this cube, corals transplanted onto artificial bases can be attached to the balance and weighed at predetermined intervals while they continue growth in the field. We also provide a set of simple equations for the volume and weight determinations required to calculate net growth rates. The new technique is highly accurate: low error of weight determinations due to variation of coral density (corals. We outline a transplantation technique for properly preparing corals for such long-term in situ experiments and measurements.

  16. Characterization of a Viking Blade Fabricated by Traditional Forging Techniques

    Science.gov (United States)

    Vo, H.; Frazer, D.; Bailey, N.; Traylor, R.; Austin, J.; Pringle, J.; Bickel, J.; Connick, R.; Connick, W.; Hosemann, P.

    2016-12-01

    A team of students from the University of California, Berkeley, participated in a blade-smithing competition hosted by the Minerals, Metals, and Materials Society at the TMS 2015 144th annual meeting and exhibition. Motivated by ancient forging methods, the UC Berkeley team chose to fabricate our blade from historical smithing techniques utilizing naturally-occurring deposits of iron ore. This approach resulted in receiving the "Best Example of a Traditional Blade Process/Ore Smelting Technique" award for our blade named "Berkelium." First, iron-enriched sand was collected from local beaches. Magnetite (Fe3O4) was then extracted from the sand and smelted into individual high- and low-carbon steel ingots. Layers of high- and low-carbon steels were forge-welded together, predominantly by hand, to form a composite material. Optical microscopy, energy dispersive spectroscopy, and Vickers hardness mechanical testing were conducted at different stages throughout the blade-making process to evaluate the microstructure and hardness evolution during formation. It was found that the pre-heat-treated blade microstructure was composed of ferrite and pearlite, and contained many nonmetallic inclusions. A final heat treatment was performed, which caused the average hardness of the blade edge to increase by more than a factor of two, indicating a martensitic transformation.

  17. Chloride ingress profiles measured by electron probe micro analysis

    DEFF Research Database (Denmark)

    Jensen, Ole mejlhede; Coats, Alison M.; Glasser, Fred P.

    1996-01-01

    Traditional techniques for measuring chloride ingress profiles do not apply well to high performance cement paste systems; the geometric resolution of the traditional measuring techniques is too low. In this paper measurements by Electron Probe Micro Analysis (EPMA) are presented. EPMA is demonst......Traditional techniques for measuring chloride ingress profiles do not apply well to high performance cement paste systems; the geometric resolution of the traditional measuring techniques is too low. In this paper measurements by Electron Probe Micro Analysis (EPMA) are presented. EPMA...... is demonstated to determine chloride ingress in cement paste on a micrometer scale. Potential chloride ingress routes such as cracks or the paste-aggregate interface may also be characterized by EPMA. Copyright (C) 1996 Elsevier Science Ltd...

  18. Earth construction: traditional building techniques of Bhutan

    Directory of Open Access Journals (Sweden)

    João M. Guedes

    2018-01-01

    Full Text Available NCREP – Consultancy in Rehabilitation of Built Heritage Ltd., surveyed the constructive features of Bhutan's vernacular rammed earth built heritage, as part of a project financed by the World Bank and commissioned by the Division for the Conservation of Heritage Sites (DCHS of the Department of Culture - Ministry of Home and Cultural Affairs of Bhutan. This work, which aimed at better understanding the structural behaviour of this heritage and, based on this information, proposing measures to mitigate its seismic risk, included the study of 18 traditional rammed earth buildings in two villages in the Punakha district. The surveys were conducted house-to-house, based on a DCHS script, and included surveys of artisans responsible for building these constructive typologies, supported by a questionnaire integrated within the project, to collect information on the procedures, rites and practices followed in these constructions. This article focuses only on the first part of the work; it presents the main constructive characteristics assessed from the survey carried out on this built heritage and compiles the results of the surveys of the artisans.

  19. Objectively measured sedentary behavior in preschool children: comparison between Montessori and traditional preschools

    Directory of Open Access Journals (Sweden)

    Byun Wonwoo

    2013-01-01

    Full Text Available Abstract Background This study aimed to compare the levels of objectively-measured sedentary behavior in children attending Montessori preschools with those attending traditional preschools. Methods The participants in this study were preschool children aged 4 years old who were enrolled in Montessori and traditional preschools. The preschool children wore ActiGraph accelerometers. Accelerometers were initialized using 15-second intervals and sedentary behavior was defined as Results Children attending Montessori preschools spent less time in sedentary behavior than those attending traditional preschools during the in-school (44.4. min/hr vs. 47.1 min/hr, P = 0.03, after-school (42.8. min/hr vs. 44.7 min/hr, P = 0.04, and total-day (43.7 min/hr vs. 45.5 min/hr, P = 0. 009 periods. School type (Montessori or traditional, preschool setting (private or public, socio-demographic factors (age, gender, and socioeconomic status were found to be significant predictors of preschoolers’ sedentary behavior. Conclusions Levels of objectively-measured sedentary behavior were significantly lower among children attending Montessori preschools compared to children attending traditional preschools. Future research should examine the specific characteristics of Montessori preschools that predict the lower levels of sedentary behavior among children attending these preschools compared to children attending traditional preschools.

  20. Objectively measured sedentary behavior in preschool children: comparison between Montessori and traditional preschools.

    Science.gov (United States)

    Byun, Wonwoo; Blair, Steven N; Pate, Russell R

    2013-01-03

    This study aimed to compare the levels of objectively-measured sedentary behavior in children attending Montessori preschools with those attending traditional preschools. The participants in this study were preschool children aged 4 years old who were enrolled in Montessori and traditional preschools. The preschool children wore ActiGraph accelerometers. Accelerometers were initialized using 15-second intervals and sedentary behavior was defined as Montessori preschools, after adjusting for selected potential correlates of preschoolers' sedentary behavior. Children attending Montessori preschools spent less time in sedentary behavior than those attending traditional preschools during the in-school (44.4. min/hr vs. 47.1 min/hr, P = 0.03), after-school (42.8. min/hr vs. 44.7 min/hr, P = 0.04), and total-day (43.7 min/hr vs. 45.5 min/hr, P = 0. 009) periods. School type (Montessori or traditional), preschool setting (private or public), socio-demographic factors (age, gender, and socioeconomic status) were found to be significant predictors of preschoolers' sedentary behavior. Levels of objectively-measured sedentary behavior were significantly lower among children attending Montessori preschools compared to children attending traditional preschools. Future research should examine the specific characteristics of Montessori preschools that predict the lower levels of sedentary behavior among children attending these preschools compared to children attending traditional preschools.

  1. Industrial level measurement techniques - a review

    International Nuclear Information System (INIS)

    Schaudel, D.E.

    1984-01-01

    The outlined methods of industrial level measurement technique are nowadays in current use. In correspondence with the technical evolution the mechanical techniques are mentioned first, followed by a description of the more modern electronic methods. These measurement methods comply especially to the requirements of computer aided process guiding systems, i.e. compatibility of signals, self-checking and reliability. (orig.) [de

  2. Isotope measurement techniques for atmospheric methane

    International Nuclear Information System (INIS)

    Lowe, D.; White, J.; Levin, I.; Wahlen, M.; Miller, J.B.; Bergamaschi, P.

    2002-01-01

    Measurement techniques for the carbon isotopic composition of atmospheric methane (δ 13 C) are described in detail as applied in several leading institutions active in this field since many years. The standard techniques with offline sample preparation and subsequent measurement by dual inlet isotope ratio mass spectrometry (IRMS) are compared with continuous flow IRMS. The potential use of infrared absorption spectroscopy is briefly discussed. Details on quality control and calibration are provided. Basic analytical aspects for the measurement of other species, 2 H and 14 C, are also given. (author)

  3. The Recent Performance of the Traditional Measure of Core Inflation in G7 Countries

    OpenAIRE

    Luciana Lo Bue; Antonio Ribba

    2009-01-01

    In this paper we undertake an empirical investigation concerning the performance of the traditional measure of core inflation in recent years. We consider the group of G7 countries and explore both the high-frequency and the low-frequency relations between overall inflation and core inflation. We find that the traditional core measure, obtained by subtracting from the overall index those components which exhibit high volatility and which are responsible for the short-run variability of inflat...

  4. Hole Drilling Technique – on site stress measurement

    OpenAIRE

    Schueremans, Luc

    2009-01-01

    2. Hole Drilling Technique for onsite stress measurement has been used to validate the stress level at 2 pillars of the Sint-Jacobschurch (Leuven, B). The technique allows estimating the stress in a stone from measuring deformation when a small hole is made. It is a low intrusive technique. The application of it is limited to local stress measurements and is a complement to stress estimate from calculations of from the use of –for example- flat jacks. In addition to the flat-jack technique...

  5. Sadum: Traditional and Contemporary

    Directory of Open Access Journals (Sweden)

    Ratna Panggabean

    2009-07-01

    Full Text Available Sadum is one of the traditional cloths of the Batak people in North Sumatra. It is woven on a back strap loom with supplementary weft technique. Sadum is a warp faced weaving made of cotton and beads woven into the cloth. Ritually it is used as a shoulder cloth, gifts exchanges, and in dances. It also bears the symbol of good tidings and blessings for the receiver. The cloth has change during times in technique, color, patterns, as well as in functions. But the use as a ritual cloth stays the same. The basic weaving techniques and equipments used to create it hasn’t change, but its material and added techniques has made this cloth become more rich in color, pattern, and texture. Most changes began when the Europeans came to Indonesia and introduced new material such as synthetic fibers and colors. In the 70s traditional cloth of Indonesia got its boost when the government declared batik as Indonesian national attire. This encourages other traditional weavings to develop into contemporary clothing. Later, new techniques and material were introduced to the Sadum weavings including embroidery, silk and golden threads which were never used before.

  6. Application of metabonomic analytical techniques in the modernization and toxicology research of traditional Chinese medicine.

    Science.gov (United States)

    Lao, Yong-Min; Jiang, Jian-Guo; Yan, Lu

    2009-08-01

    In the recent years, a wide range of metabonomic analytical techniques are widely used in the modern research of traditional Chinese medicine (TCM). At the same time, the international community has attached increasing importance to TCM toxicity problems. Thus, many studies have been implemented to investigate the toxicity mechanisms of TCM. Among these studies, many metabonomic-based methods have been implemented to facilitate TCM toxicity investigation. At present, the most prevailing methods for TCM toxicity research are mainly single analysis techniques using only one analytical means. These techniques include nuclear magnetic resonance (NMR), gas chromatography-mass spectrometry (GC-MS), and liquid chromatography-mass spectrometry (LC-MS), etc.; with these techniques, some favourable outcomes have been gained in the toxic reaction studies of TCM, such as the action target organs assay, the establishment of action pattern, the elucidation of action mechanism and the exploration of action material foundation. However, every analytical technique has its advantages and drawbacks, no existing analytical technique can be versatile. Multi-analysed techniques can partially overcome the shortcomings of single-analysed techniques. Combination of GC-MS and LC-MS metabolic profiling approaches has unravelled the pathological outcomes of aristolochic acid-induced nephrotoxicity, which can not be achieved by single-analysed techniques. It is believed that with the further development of metabonomic analytical techniques, especially multi-analysed techniques, metabonomics will greatly promote TCM toxicity research and be beneficial to the modernization of TCM in terms of extending the application of modern means in the TCM safety assessment, assisting the formulation of TCM safety norms and establishing the international standards indicators.

  7. Deformation Monitoring for Chinese Traditional Timber Buildings Using Fiber Bragg Grating Sensors

    Directory of Open Access Journals (Sweden)

    Ni-Lei Li

    2018-06-01

    Full Text Available The Fiber Bragg Grating (FBG sensing technique is suitable for a wide variety of measurements, including temperature, pressure, acceleration, liquid level, etc., and has been applied to many bridges and buildings in the past two decades. The fact that the FBG technique can only monitor and measure strain data for most cases when it is used for deformation measurements impedes application of the FBG sensing technique in civil infrastructures. This paper proposes FBG sensing-based deformation monitoring methods that are applicable to monitoring beam deflection, column inclination angle and mortise-tenon joint dislocation for Chinese traditional timber structures. On the basis of improved conjugated beam theory and geometrical trigonometric function relationship, the relationships between the FBG sensing strain values and the deflection of beam, inclination angle of column, as well as the amount of dislocation of mortise-tenon joint are deducted for Chinese traditional buildings. A series of experiments were conducted to verify the applicability and effectiveness of the proposed deformation monitoring methods. The results show that a good agreement is obtained between the values given by the methods proposed in this paper and other methods. This implies that the proposed deformation monitoring methods are applicable and effective in the health monitoring of Chinese traditional timber structures.

  8. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  9. Measurements Techniques for Gyrotron characterization

    International Nuclear Information System (INIS)

    Castro, P.J. de.

    1987-08-01

    Experiments planned for the characterization of the 35GHz girotron, which is being built at the Plasma Laboratory of INPE, are described. The methods of the measurements are presented and the required instrumentation and devices are specified. Special attention is given to the measurement techniques of the resonator electric field profile. (author) [pt

  10. Experimental techniques of conversion coefficient measurements

    International Nuclear Information System (INIS)

    Hamilton, J.H.

    1975-01-01

    Discusses briefly the history of conversion electron spectra measurements, and the interpretation of the collected data. Then provides a comprehensive review of techniques presently available to measure the conversion coefficients. (Auth.)

  11. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  12. Spectrometry techniques for radioactivity measurements

    International Nuclear Information System (INIS)

    Anilkumar, S.

    2016-01-01

    The energy of the radiation emission following the nuclear decay is unique and the characteristic of the radio nuclide which undergoes decay. Thus measurement of the energy of the radiation offers a method of identifying the radio nuclides. The prime requirement of the energy measurement is a suitable detector which shows response proportional to the energy of the radiation rather than the presence of the radiation. The response from such detectors are suitably processed and distributed with respect to the signal strength which is proportional to incident energy. This distribution is normally referred as energy spectrum and is recorded in the multichannel analyser. The measurement of energy and intensity of radiation from the spectrum is called radiation spectrometry. Thus the radiation spectrometry allows the identification and quantification of radioactive isotopes in variety of matrices. The radiation spectrometry has now become a popular radioanalytical technique in wide area of nuclear fuel cycle programs. The popular spectrometry techniques commonly used for the radioactivity measurement and analysis are Alpha spectrometry, Gamma ray spectrometry and Beta spectrometry

  13. Combined Characterization of the Time Response of Impression Materials via Traditional and FTIR Measurements

    Directory of Open Access Journals (Sweden)

    Giacomo Derchi

    2015-05-01

    Full Text Available We investigated the temporal response of four dental impression materials, namely three siloxanes (Imprint 4, Flexitime, Aquasil and one polyether (Impregum. The null hypothesis was that the nominal working times are confirmed by instrumental laboratory tests. We also aimed to identify alternative techniques with strong physical-chemical background for the assessment of temporal response. Traditional characterization was carried out by shark fin test device and durometer at both ambient and body temperature. Additionally, Fourier-transform infrared spectroscopy was performed at room temperature. From shark fin height and Shore hardness versus time the working time and the setting time of the materials were evaluated, respectively. These were in reasonable agreement with the nominal values, except for Impregum, which showed longer working time. Spectroscopy confirmed the different character of the two types of materials, and provided for Imprint 4 and Aquasil an independent evaluation of both evolution times, consistent with the results of the other techniques. Shark fin test and durometer measurements showed deviations in setting time, low sensitivity to temperature for Flexitime, and longer working time at higher temperature for Impregum. Deviations of working time appear in operating conditions from what specified by the manufacturers. Fourier-transform infrared spectroscopy can provide insight in the correlation between material properties and their composition and structure.

  14. Water stable isotope measurements of Antarctic samples by means of IRMS and WS-CRDS techniques

    Science.gov (United States)

    Michelini, Marzia; Bonazza, Mattia; Braida, Martina; Flora, Onelio; Dreossi, Giuliano; Stenni, Barbara

    2010-05-01

    of the sample in the box. In the WS-CRDS the path of laser is longer, producing higher-sensitivity measurements. The instrument is paired with an autosampler and can be used without it and the vaporizer to analyze directly the isotopic composition of the water vapour in the atmosphere. In addition, the instrument can be moved from the laboratory and also used for outdoor measurements. The more important improvements over traditional IRMS techniques are that WS-CRDS needs less sample in order to perform the analysis (water equilibration techniques) and the analyses are faster. Coversely, memory effects may affect the measurements so there is the need to increase the number of injection to have a high precision measurement. The laboratory of Isotope Geochemistry of the Department of Geosciences has recently acquired a WS-CRDS system from PICARRO. The isotopic data obtained with this new method have been compared with the ones obtained by means of IRMS methods. An HDO device coupled with a Thermo Finnigan Delta Plus Advantage mass spectrometer has been used, using the well know CO2 and H2/water equilibration technique. At the moment of the writing of the abstract the mean difference between the values obtained using PICARRO and using the traditional IRMS method is of the order of 0.1 per mil for the ratio 18O/16O and 1.00 per mil for the ratio D/H, but further measurements are currently underway. O'Keef A., Deacon D.A.G., 1988. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources, Rev. Sci. Instrum., 59, 2544.

  15. Measurement techniques for radio frequency nanoelectronics

    CERN Document Server

    Wallis, T Mitch

    2017-01-01

    Connect basic theory with real-world applications with this practical, cross-disciplinary guide to radio frequency measurement of nanoscale devices and materials.• Learn the techniques needed for characterizing the performance of devices and their constituent building blocks, including semiconducting nanowires, graphene, and other two dimensional materials such as transition metal dichalcogenides• Gain practical insights into instrumentation, including on-wafer measurement platforms and scanning microwave microscopy• Discover how measurement techniques can be applied to solve real-world problems, in areas such as passive and active nanoelectronic devices, semiconductor dopant profiling, subsurface nanoscale tomography, nanoscale magnetic device engineering, and broadband, spatially localized measurements of biological materialsFeaturing numerous practical examples, and written in a concise yet rigorous style, this is the ideal resource for researchers, practicing engineers, and graduate students new to ...

  16. Application of a two-sinker densimeter for phase-equilibrium measurements: A new technique for the detection of dew points and measurements on the (methane + propane) system

    International Nuclear Information System (INIS)

    McLinden, Mark O.; Richter, Markus

    2016-01-01

    Highlights: • A new technique for detecting dew points in fluid mixtures is described. • The method makes use of a two-sinker densimeter. • The technique is based on a quantitative measurement of sample mass adsorbed onto the surface of the densimeter sinkers. • The dew-point density and dew-point pressure are determined with low uncertainty. • The method is applied to the (methane + propane) system and compared to traditional methods. - Abstract: We explore a novel method for determining the dew-point density and dew-point pressure of fluid mixtures and compare it to traditional methods. The (p, ρ, T, x) behavior of three (methane + propane) mixtures was investigated with a two-sinker magnetic suspension densimeter over the temperature range of (248.15–293.15) K; the measurements extended from low pressures into the two-phase region. The compositions of the gravimetrically prepared mixtures were (0.74977, 0.50688, and 0.26579) mole fraction methane. We analyzed isothermal data by: (1) a “traditional” analysis of the intersection of a virial fit of the (p vs. ρ) data in the single-phase region with a linear fit of the data in the two-phase region; and (2) an analysis of the adsorbed mass on the sinker surfaces. We compared these to a traditional isochoric experiment. We conclude that the “adsorbed mass” analysis of an isothermal experiment provides an accurate determination of the dew-point temperature, pressure, and density. However, a two-sinker densimeter is required.

  17. Solar Cell Calibration and Measurement Techniques

    Science.gov (United States)

    Bailey, Sheila; Brinker, Dave; Curtis, Henry; Jenkins, Phillip; Scheiman, Dave

    2004-01-01

    The increasing complexity of space solar cells and the increasing international markets for both cells and arrays has resulted in workshops jointly sponsored by NASDA, ESA and NASA. These workshops are designed to obtain international agreement on standardized values for the AMO spectrum and constant, recommend laboratory measurement practices and establish a set of protocols for international comparison of laboratory measurements. A working draft of an ISO standard, WD15387, "Requirements for Measurement and Calibration Procedures for Space Solar Cells" was discussed with a focus on the scope of the document, a definition of primary standard cell, and required error analysis for all measurement techniques. Working groups addressed the issues of Air Mass Zero (AMO) solar constant and spectrum, laboratory measurement techniques, and te international round robin methodology. A summary is presented of the current state of each area and the formulation of the ISO document.

  18. Neutron flux measurement utilizing Campbell technique

    International Nuclear Information System (INIS)

    Kropik, M.

    2000-01-01

    Application of the Campbell technique for the neutron flux measurement is described in the contribution. This technique utilizes the AC component (noise) of a neutron chamber signal rather than a usually used DC component. The Campbell theorem, originally discovered to describe noise behaviour of valves, explains that the root mean square of the AC component of the chamber signal is proportional to the neutron flux (reactor power). The quadratic dependence of the reactor power on the root mean square value usually permits to accomplish the whole current power range of the neutron flux measurement by only one channel. Further advantage of the Campbell technique is that large pulses of the response to neutrons are favoured over small pulses of the response to gamma rays in the ratio of their mean square charge transfer and thus, the Campbell technique provides an excellent gamma rays discrimination in the current operational range of a neutron chamber. The neutron flux measurement channel using state of the art components was designed and put into operation. Its linearity, accuracy, dynamic range, time response and gamma discrimination were tested on the VR-1 nuclear reactor in Prague, and behaviour under high neutron flux (accident conditions) was tested on the TRIGA nuclear reactor in Vienna. (author)

  19. Thermal measurements and inverse techniques

    CERN Document Server

    Orlande, Helcio RB; Maillet, Denis; Cotta, Renato M

    2011-01-01

    With its uncommon presentation of instructional material regarding mathematical modeling, measurements, and solution of inverse problems, Thermal Measurements and Inverse Techniques is a one-stop reference for those dealing with various aspects of heat transfer. Progress in mathematical modeling of complex industrial and environmental systems has enabled numerical simulations of most physical phenomena. In addition, recent advances in thermal instrumentation and heat transfer modeling have improved experimental procedures and indirect measurements for heat transfer research of both natural phe

  20. Liquidus temperature and optical properties measurement by containerless techniques

    Science.gov (United States)

    Anderson, Collin D.

    1993-01-01

    Reactive alloy liquidus temperatures measured by conventional, contained techniques are often in error due to reactions with containers and gaseous impurities. This paper describes a new liquidus temperature measurement technique that avoids these problems by employing containerless processing. This technique relies on precise and accurate noncontact temperature measurements (NCTM), which are made possible by spectral emissivity values. The spectral emissivities, epsilon(sub lambda), are measured along with the optical properties (real, n, and imaginary, k, components of the index of refraction) using polarimetric techniques on electromagnetically levitated specimens. Results from work done at Vanderbilt University and Intersonics on the Ti-Al system are presented to demonstrate the above techniques.

  1. Development of Measurement Techniques For Strengthening Nuclear Safeguards

    International Nuclear Information System (INIS)

    Badawy, I.

    2007-01-01

    The strategy of nuclear safeguards is based on the accounting and control of nuclear materials, nuclear technologies and activities in a State in order to attain its ''Legal'' goals of the application of atomic energy. The present paper investigates the development in the measurement techniques used in the verification and control of NMs for the purpose of strengthening safeguards. Its focus is to review the recent nuclear measurement techniques used for the identification and verification of nuclear materials.The different levels of verification and the accuracy of these techniques are discussed. The implementation of stregthened safeguards; and nuclear materials verification and control in the world are mentioned. Also, the recently proposed measures to enhance the ability to detect undeclared nuclear materials, nuclear activities and facilities that would need advanced measurement techniques are indicated.

  2. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Cristina-Aurora, BUNEA-BONTAS

    2013-12-01

    Full Text Available Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income approach. This article reviews these techniques and points out that different valuation practices may provide different results depending on the item being fair valued and on the inputs used. Also it emphasizes that, in particular circumstances, there is the possibility that a certain technique may be more appropriate than other.

  3. Experimental techniques and measurement accuracies

    International Nuclear Information System (INIS)

    Bennett, E.F.; Yule, T.J.; DiIorio, G.; Nakamura, T.; Maekawa, H.

    1985-02-01

    A brief description of the experimental tools available for fusion neutronics experiments is given. Attention is paid to error estimates mainly for the measurement of tritium breeding ratio in simulated blankets using various techniques

  4. Fluid temperature measurement technique by using Raman scattering

    International Nuclear Information System (INIS)

    An, Jeong Soo; Yang, Sun Kyu; Min, Kyung Ho; Chung, Moon Ki; Choi, Young Don

    1999-06-01

    Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., 3 tabs., 38 figs

  5. Characteristics of Laser Flash Technique for Thermal Diffusivity Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Park, D. G.; Kim, H. M.; Hong, G. P

    2008-08-15

    In relation to selection of thermal conductivity measurement technology, various thermal conductivity measurement technique are investigated for characteristics of each technique and it's measurable range. For the related laser flash techniques, various technical characteristics are reviewed and discussed. Especially, Parker adiabatic model are reviewed because of importance for basic theory of the thermal diffusivity determination. Finite pulse time effect, heat loss effect and non-uniform heating effect, which are main technical factors for laser flash technique, are considered. Finally, characteristics of constituent elements for laser flash measurement system are reviewed and investigated in detail.

  6. Parametric model measurement: reframing traditional measurement ideas in neuropsychological practice and research.

    Science.gov (United States)

    Brown, Gregory G; Thomas, Michael L; Patt, Virginie

    Neuropsychology is an applied measurement field with its psychometric work primarily built upon classical test theory (CTT). We describe a series of psychometric models to supplement the use of CTT in neuropsychological research and test development. We introduce increasingly complex psychometric models as measurement algebras, which include model parameters that represent abilities and item properties. Within this framework of parametric model measurement (PMM), neuropsychological assessment involves the estimation of model parameters with ability parameter values assuming the role of test 'scores'. Moreover, the traditional notion of measurement error is replaced by the notion of parameter estimation error, and the definition of reliability becomes linked to notions of item and test information. The more complex PMM approaches incorporate into the assessment of neuropsychological performance formal parametric models of behavior validated in the experimental psychology literature, along with item parameters. These PMM approaches endorse the use of experimental manipulations of model parameters to assess a test's construct representation. Strengths and weaknesses of these models are evaluated by their implications for measurement error conditional upon ability level, sensitivity to sample characteristics, computational challenges to parameter estimation, and construct validity. A family of parametric psychometric models can be used to assess latent processes of interest to neuropsychologists. By modeling latent abilities at the item level, psychometric studies in neuropsychology can investigate construct validity and measurement precision within a single framework and contribute to a unification of statistical methods within the framework of generalized latent variable modeling.

  7. Measurement of void fractions by nuclear techniques

    International Nuclear Information System (INIS)

    Hernandez G, A.; Vazquez G, J.; Diaz H, C.; Salinas R, G.A.

    1997-01-01

    In this work it is done a general analysis of those techniques used to determine void fractions and it is chosen a nuclear technique to be used in the heat transfer circuit of the Physics Department of the Basic Sciences Management. The used methods for the determination of void fractions are: radioactive absorption, acoustic techniques, average velocity measurement, electromagnetic flow measurement, optical methods, oscillating absorption, nuclear magnetic resonance, relation between pressure and flow oscillation, infrared absorption methods, sound neutron analysis. For the case of this work it will be treated about the radioactive absorption method which is based in the gamma rays absorption. (Author)

  8. Fit accuracy of metal partial removable dental prosthesis frameworks fabricated by traditional or light curing modeling material technique: An in vitro study

    Science.gov (United States)

    Anan, Mohammad Tarek M.; Al-Saadi, Mohannad H.

    2015-01-01

    Objective The aim of this study was to compare the fit accuracies of metal partial removable dental prosthesis (PRDP) frameworks fabricated by the traditional technique (TT) or the light-curing modeling material technique (LCMT). Materials and methods A metal model of a Kennedy class III modification 1 mandibular dental arch with two edentulous spaces of different spans, short and long, was used for the study. Thirty identical working casts were used to produce 15 PRDP frameworks each by TT and by LCMT. Every framework was transferred to a metal master cast to measure the gap between the metal base of the framework and the crest of the alveolar ridge of the cast. Gaps were measured at three points on each side by a USB digital intraoral camera at ×16.5 magnification. Images were transferred to a graphics editing program. A single examiner performed all measurements. The two-tailed t-test was performed at the 5% significance level. Results The mean gap value was significantly smaller in the LCMT group compared to the TT group. The mean value of the short edentulous span was significantly smaller than that of the long edentulous span in the LCMT group, whereas the opposite result was obtained in the TT group. Conclusion Within the limitations of this study, it can be concluded that the fit of the LCMT-fabricated frameworks was better than the fit of the TT-fabricated frameworks. The framework fit can differ according to the span of the edentate ridge and the fabrication technique for the metal framework. PMID:26236129

  9. Comparative study of presurgical hand hygiene with hydroalcoholic solution versus traditional presurgical hand hygiene.

    Science.gov (United States)

    López Martín, M Beatriz; Erice Calvo-Sotelo, Alejo

    To compare presurgical hand hygiene with hydroalcoholic solution following the WHO protocol with traditional presurgical hand hygiene. Cultures of the hands of surgeons and surgical nurses were performed before and after presurgical hand hygiene and after removing gloves at the end of surgery. Cultures were done in 2different days: the first day after traditional presurgical hand hygiene, and the second day after presurgical hand hygiene with hydroalcoholic solution following the WHO protocol. The duration of the traditional hand hygiene was measured and compared with the duration (3min) of the WHO protocol. The cost of the products used in the traditional technique was compared with the cost of the hydroalcoholic solution used. The variability of the traditional technique was determined by observation. Following presurgical hand hygiene with hydroalcoholic solution, colony-forming units (CFU) were detected in 5 (7.3%) subjects, whereas after traditional presurgical hand hygiene CFU were detected in 14 subjects (20.5%) (p < 0.05). After glove removal, the numbers of CFU were similar. The time employed in hand hygiene with hydroalcoholic solution (3min) was inferior to the time employed in the traditional technique (p < 0.05), its cost was less than half, and there was no variability. Compared with other techniques, presurgical hand hygiene with hydroalcoholic solution significantly decreases CFU, has similar latency time, a lower cost, and saves time. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  10. An improved technique for quasi-static C-V measurements

    International Nuclear Information System (INIS)

    Turan, R.; Finstad, T.G.

    1990-10-01

    A new automated quasi-static C-V measurement technique for MOS capacitors has been developed. This techniques uses an integrating electrometer to measure the charge accumulated on a MOS capacitor in response of a small voltage step. Making use of the internal data storage system of a commercial electrometer and a personal computer, the charge Q on the MOS capacitor is measured as a function of time t and stored. The capacitance is then obtained by analyzing this Q-t data set. A Si MOS sample is measured and analyzed in terms of interface charges as an example. Advantages over a commercial quasi-static meter which uses similar measurement technique are presented. It is also shown that this technique is potentially capable of measuring both high and low frequency C-V curves simultaneously. 9 refs. 5 figs

  11. A new lowry's technique for quantitative measurement of protein

    International Nuclear Information System (INIS)

    Chen Ge; Zou Wenquan; Sun Jianzhong; Zhang Yanggang; Shu Bohua; Liu Shenpei; Gong Xiaoliang

    1990-01-01

    According to the queneching principle in beta ray measurement, liquid scintillation counters are used for quantitative measurement of protein. The results show linear relationship between the colored protein samples with different concentrations and the counting rate of LSC. It is proved that LSC method is less erroneous and has larger measurement range than the traditional photoelectric colorimetry, and the analysis is easy to be automatized

  12. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    Science.gov (United States)

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart

  13. Techniques and tools for measuring energy efficiency of scientific software applications

    International Nuclear Information System (INIS)

    Abdurachmanov, David; Elmer, Peter; Eulisse, Giulio; Knight, Robert; Niemi, Tapio; Pestana, Gonçalo; Khan, Kashif; Nurminen, Jukka K; Nyback, Filip; Ou, Zhonghong

    2015-01-01

    The scale of scientific High Performance Computing (HPC) and High Throughput Computing (HTC) has increased significantly in recent years, and is becoming sensitive to total energy use and cost. Energy-efficiency has thus become an important concern in scientific fields such as High Energy Physics (HEP). There has been a growing interest in utilizing alternate architectures, such as low power ARM processors, to replace traditional Intel x86 architectures. Nevertheless, even though such solutions have been successfully used in mobile applications with low I/O and memory demands, it is unclear if they are suitable and more energy-efficient in the scientific computing environment. Furthermore, there is a lack of tools and experience to derive and compare power consumption between the architectures for various workloads, and eventually to support software optimizations for energy efficiency. To that end, we have performed several physical and software-based measurements of workloads from HEP applications running on ARM and Intel architectures, and compare their power consumption and performance. We leverage several profiling tools (both in hardware and software) to extract different characteristics of the power use. We report the results of these measurements and the experience gained in developing a set of measurement techniques and profiling tools to accurately assess the power consumption for scientific workloads. (paper)

  14. Combining traditional dietary assessment methods with novel metabolomics techniques: present efforts by the Food Biomarker Alliance

    DEFF Research Database (Denmark)

    Brouwer-Brolsma, Elske M; Brennan, Lorraine; Drevon, Christian A

    2017-01-01

    food metabolomics techniques that allow the quantification of up to thousands of metabolites simultaneously, which may be applied in intervention and observational studies. As biomarkers are often influenced by various other factors than the food under investigation, FoodBAll developed a food intake...... in these metabolomics studies, knowledge about available electronic metabolomics resources is necessary and further developments of these resources are essential. Ultimately, present efforts in this research area aim to advance quality control of traditional dietary assessment methods, advance compliance evaluation...

  15. Vessel size measurements in angiograms: A comparison of techniques

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Nazareth, Daryl P.; Miskolczi, Laszlo; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2002-01-01

    As interventional procedures become more complicated, the need for accurate quantitative vascular information increases. In response to this need, many commercial vendors provide techniques for measurement of vessel sizes, usually based on derivative techniques. In this study, we investigate the accuracy of several techniques used in the measurement of vessel size. Simulated images of vessels having circular cross sections were generated and convolved with various focal spot distributions taking into account the magnification. These vessel images were then convolved with Gaussian image detector line spread functions (LSFs). Additionally, images of a phantom containing vessels with a range of diameters were acquired for the 4.5'', 6'', 9'', and 12'' modes of an image intensifier-TV (II-TV) system. Vessel sizes in the images were determined using a first-derivative technique, a second-derivative technique, a linear combination of these two measured sizes, a thresholding technique, a densitometric technique, and a model-based technique. For the same focal spot size, the shape of the focal spot distribution does not affect measured vessel sizes except at large magnifications. For vessels with diameters larger than the full-width-at-half-maximum (FWHM) of the LSF, accurate vessel sizes (errors ∼0.1 mm) could be obtained by using an average of sizes determined by the first and second derivatives. For vessels with diameters smaller than the FWHM of the LSF, the densitometric and model-based techniques can provide accurate vessel sizes when these techniques are properly calibrated

  16. Radiotracer techniques for measuring fluid flow and calibrating flow meters

    International Nuclear Information System (INIS)

    Cooper, E.L.

    1987-08-01

    Radiotracer techniques can be used to measure accurately both gas and liquid flow rates under operating conditions in a wide range of flow systems. They are ideally suited for calibrating flow meters as well as for measuring unmetered flows in industrial plants. Applications of these techniques range from measuring the flows of fuels and process fluids for energy and mass balance studies to measuring the flows of liquid and airborne effluents for pollution control. This report describes the various radiotracer techniques which can be used to measure fluid flows. The range of application and inherent accuracy of each technique is discussed

  17. The Sine Method: An Alternative Height Measurement Technique

    Science.gov (United States)

    Don C. Bragg; Lee E. Frelich; Robert T. Leverett; Will Blozan; Dale J. Luthringer

    2011-01-01

    Height is one of the most important dimensions of trees, but few observers are fully aware of the consequences of the misapplication of conventional height measurement techniques. A new approach, the sine method, can improve height measurement by being less sensitive to the requirements of conventional techniques (similar triangles and the tangent method). We studied...

  18. Recent developments in magnet measuring techniques

    International Nuclear Information System (INIS)

    Billan, J.; Henrichsen, K.N.; Walckiers, L.

    1985-01-01

    The main problems related to magnetic measurements of particle accelerator components are discussed. Measurements of the properties of magnetic materials as well as the measurements of field distribution in the electromagnets for the Large Electron-Positron Collider (LEP) are illustrated. The fluxmeter method is extensively employed in this work. The impact of recent advances in electronic technology on measurement techniques is explained. Magnetic measurements (including the harmonic coil method) can be performed with improved accuracy applying modern technology to the classical methods. New methods for the non-destructive testing of magnetic materials and for the measurement of magnetic geometry are described. (orig.) [de

  19. Error reduction techniques for measuring long synchrotron mirrors

    International Nuclear Information System (INIS)

    Irick, S.

    1998-07-01

    Many instruments and techniques are used for measuring long mirror surfaces. A Fizeau interferometer may be used to measure mirrors much longer than the interferometer aperture size by using grazing incidence at the mirror surface and analyzing the light reflected from a flat end mirror. Advantages of this technique are data acquisition speed and use of a common instrument. Disadvantages are reduced sampling interval, uncertainty of tangential position, and sagittal/tangential aspect ratio other than unity. Also, deep aspheric surfaces cannot be measured on a Fizeau interferometer without a specially made fringe nulling holographic plate. Other scanning instruments have been developed for measuring height, slope, or curvature profiles of the surface, but lack accuracy for very long scans required for X-ray synchrotron mirrors. The Long Trace Profiler (LTP) was developed specifically for long x-ray mirror measurement, and still outperforms other instruments, especially for aspheres. Thus, this paper focuses on error reduction techniques for the LTP

  20. Complex technique for materials hardness measurement

    Energy Technology Data Exchange (ETDEWEB)

    Krashchenko, V P; Oksametnaya, O B

    1984-01-01

    A review of existing methods of measurement of material hardness in national and foreign practice has been made. A necessity of improving the technique of material hardness measurement in a wide temperature range and insuring load change with indenting, continuity of imprint application, smooth changing of temperatures along a sample length, and deformation rate control has been noted.

  1. Ultrasonic technique for measuring porosity of plasma-sprayed alumina coatings

    Science.gov (United States)

    Parthasarathi, S.; Tittmann, B. R.; Onesto, E. J.

    1997-12-01

    Porosity is an important factor in plasma-sprayed coatings, especially ceramic coatings. Excessive poros-ity can adversely affect the performance of the coated component in various ways. An ultrasonic nonde-structive measurement technique has been developed to measure porosity in plasma-sprayed alumina coatings. The technique is generic and can be extended to other ceramic coating systems. To test the tech-nique, freestanding alumina coatings with varying levels of porosity were fabricated via plasma spray. Samples with varying porosity, obtained through innovative fabrication techniques, were used to gener-ate a calibration curve. The ultrasonic velocity in the low-frequency range was found to be dependent on the density of freestanding coatings (measured via Archimedian techniques). This dependence is the basis of the development of a technique to measure the density of coatings.

  2. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  3. Phase Retrieval Techniques In Coordinates Measurement

    International Nuclear Information System (INIS)

    Harizanova, J. I.; Stoykova, E. V.; Sainov, V. C.

    2007-01-01

    A precise pattern projection profilometry for three-dimensional shape measurements with different methods of fringe generation is presented. The application of phase-shifting algorithm along with two-spacing illumination allow for phase retrieval and estimation of relative and absolute coordinates of the tested samples. The following experimental approaches for fringe generation are investigated: interferometric approach based on a classical Michelson interferometer, digital computation with a DMD projection and light modulation by a sinusoidal phase grating. The theoretical background, experimental results as well as comparison of the applied generation methods are analyzed. The obtained outcomes successfully display the applicability of this technique for surface profile measurement. The application of the proposed techniques for remote, non-destructive in-situ inspection of real objects from cultural heritage is discussed

  4. ANALYSIS OF TRADITIONAL BUILDING TECHNIQUES AND DAMAGE ASSESSMENT OF TRADITIONAL TURKISH HOUSE

    Directory of Open Access Journals (Sweden)

    Mine Tanac Zeren

    2015-03-01

    Full Text Available Western part of the Anatolia is one of the most important regions of the World that many civilizations have lived during the history since ancient times. Kula is an important historical town dating back to 17th century and is hosting important timber farmed structures (mansions unique with their space organizations, architectural features and structural system. This study creates an analysis model which is based on a detailed case study, defining structural system and damage causes for the upcoming restoration works within the region, and this methodology can be applied for other traditional regions as well.

  5. Spherical near-field antenna measurements — The most accurate antenna measurement technique

    DEFF Research Database (Denmark)

    Breinbjerg, Olav

    2016-01-01

    The spherical near-field antenna measurement technique combines several advantages and generally constitutes the most accurate technique for experimental characterization of radiation from antennas. This paper/presentation discusses these advantages, briefly reviews the early history and present...

  6. [Cholinesterases in total blood measured with a semiquantitative technique, and plasma or erythrocyte cholinesterases measured with quantitative techniques].

    Science.gov (United States)

    Carmona-Fonseca, Jaime

    2007-06-01

    An equivalence model which allows comparison of blood cholinesterase values, measured by Lovibond (semiquantitative technique), and Michel, EQM, Monotest (erythrocyte and plasma cholinesterases) values measured by quantitative techniques is required. The performance of Lovibond (Edson tintometric and Limperos & Ranta techniques) were compared with quantitative techniques. The experimental design was descriptive, cross-sectional, and prospective. From a working population (18-59 years) in Valle de Aburrá and Near East of Antioquia. 827 representative samples were chosen for their lack of exposure to cholinesterase-inhibiting plaguicides and affiliated to the Social Security System. (1) 827 workers were classified by Lovibond in four categories: 821 values with 75% of cholinesterase activity or greater (categories 75, 87.5 and 100%) and 6 with cholinesterase activity smaller than 75%. (2) With each quantitative method, the mean values of erythrocyte and plasmatic cholinesterase corresponding to the four values obtained with Lovibond were statistically different to each other. (3) The mean values of each quantitative technique increased when increased the tintometric method value. (4) Lovibond classified the low enzymatic erythrocyte activity very poorly (61-73%), but the classification of the low enzymatic plasma activity was almost completely in error (94-96%). The values of erythrocyte or plasma cholinesterase were adequately estimated by both the quantitative techniques of Michel and EQM and by Lovibond, but only when the enzymatic activity is normal. Lovibond, however, had a poor capacity to designate as "low" the values that were low according to the quantitative tests.

  7. Optical techniques for in-core measurements

    International Nuclear Information System (INIS)

    Brichard, B.

    2007-01-01

    The in-situ measurement of dimensional changes is a key issue for advanced irradiation programs in Material Test Reactors. It is for example crucial to monitor the changes of the dimensions of nuclear fuel assemblies as well as those of mechanically stressed structural material samples during in-pile irradiations. Different techniques already exist to carry out such measurements but they all come with a number of drawbacks. SCK-CEN and CEA have therefore decided to share the development of a measurement system that was never applied before in the core of a nuclear reactor. It relies on optical dimensional measurements and brings along unprecedented non-intrusiveness combined with high resolution. A clear advantage in using compact optical sensors results in a more efficient occupation of the irradiation volume available for target testings as well as a significant reduction of the gamma-heating associated with the in-pile instrumentation. The objectives of these shared studies are to design, develop, test and qualify an in-pile dimensional measurement system based on optical techniques, with the goal to implement this system in future MTR irradiation experiments. In 2006, we focussed our activities on sensor analysis, selection of the sensor prototypes, procurement and first irradiation experiment

  8. [Ideas and methods of two-dimensional zebrafish model combined with chromatographic techniques in high-throughput screening of active anti-osteoporosis components of traditional Chinese medicines].

    Science.gov (United States)

    Wei, Ying-Jie; Jing, Li-Jun; Zhan, Yang; Sun, E; Jia, Xiao-Bin

    2014-05-01

    To break through the restrictions of the evaluation model and the quantity of compounds by using the two-dimensional zebrafish model combined with chromatographic techniques, and establish a new method for the high-throughput screening of active anti-osteoporosis components. According to the research group-related studies and relevant foreign literatures, on the basis of the fact that the zebrafish osteoporosis model could efficiently evaluate the activity, the zebrafish metabolism model could efficiently enrich metabolites and the chromatographic techniques could efficiently separate and analyze components of traditional Chinese medicines, we proposed that the inherent combination of the three methods is expected to efficiently decode in vivo and in vitro efficacious anti-osteoporosis materials of traditional Chinese medicines. The method makes it simple and efficient in the enrichment, separation and analysis on components of traditional Chinese medicines, particularly micro-components and metabolites and the screening anti-osteoporosis activity, fully reflects that efficacious materials of traditional Chinese medicines contain original components and metabolites, with characteristic of "multi-components, multi-targets and integral effect", which provides new ideas and methods for the early and rapid discovery of active anti-osteoporosis components of traditional Chinese medicines.

  9. Traditional Chinese food technology and cuisine.

    Science.gov (United States)

    Li, Jian-rong; Hsieh, Yun-Hwa P

    2004-01-01

    From ancient wisdom to modern science and technology, Chinese cuisine has been established from a long history of the country and gained a global reputation of its sophistication. Traditional Chinese foods and cuisine that exhibit Chinese culture, art and reality play an essential role in Chinese people's everyday lives. Recently, traditional Chinese foods have drawn a great degree of attention from food scientists and technologists, the food industry, and health promotion institutions worldwide due to the extensive values they offer beyond being merely another ethnic food. These traditional foods comprise a wide variety of products, such as pickled vegetables, salted fish and jellyfish, tofu and tofu derived products, rice and rice snack foods, fermented sauces, fish balls and thousand-year-old eggs. An overview of selected popular traditional Chinese foods and their processing techniques are included in this paper. Further development of the traditional techniques for formulation and production of these foods is expected to produce economic, social and health benefits.

  10. Two-phase flow measurement by pulsed neutron activation techniques

    International Nuclear Information System (INIS)

    Kehler, P.

    1978-01-01

    The Pulsed Neutron Activation (PNA) technique for measuring the mass flow velocity and the average density of two-phase mixtures is described. PNA equipment can be easily installed at different loops, and PNA techniques are non-intrusive and independent of flow regimes. These features of the PNA technique make it suitable for in-situ measurement of two-phase flows, and for calibration of more conventional two-phase flow measurement devices. Analytic relations governing the various PNA methods are derived. The equipment and procedures used in the first air-water flow measurement by PNA techniques are discussed, and recommendations are made for improvement of future tests. In the present test, the mass flow velocity was determined with an accuracy of 2 percent, and average densities were measured down to 0.08 g/cm 3 with an accuracy of 0.04 g/cm 3 . Both the accuracy of the mass flow velocity measurement and the lower limit of the density measurement are functions of the injected activity and of the total number of counts. By using a stronger neutron source and a larger number of detectors, the measurable density can be decreased by a factor of 12 to .007 g/cm 3 for 12.5 cm pipes, and to even lower ranges for larger pipes

  11. Assessing the performance of prediction models: a framework for traditional and novel measures

    DEFF Research Database (Denmark)

    Steyerberg, Ewout W; Vickers, Andrew J; Cook, Nancy R

    2010-01-01

    The performance of prediction models can be assessed using a variety of methods and metrics. Traditional measures for binary and survival outcomes include the Brier score to indicate overall model performance, the concordance (or c) statistic for discriminative ability (or area under the receiver...

  12. Assessing the performance of prediction models: A framework for traditional and novel measures

    NARCIS (Netherlands)

    E.W. Steyerberg (Ewout); A.J. Vickers (Andrew); N.R. Cook (Nancy); T.A. Gerds (Thomas); M. Gonen (Mithat); N. Obuchowski (Nancy); M. Pencina (Michael); M.W. Kattan (Michael)

    2010-01-01

    textabstractThe performance of prediction models can be assessed using a variety of methods and metrics. Traditional measures for binary and survival outcomes include the Brier score to indicate overall model performance, the concordance (or c) statistic for discriminative ability (or area under the

  13. Stevens’ forgotten crossroads: The divergent measurement traditions in the physical and psychological sciences from the mid-20th century

    Directory of Open Access Journals (Sweden)

    Joshua A McGrane

    2015-04-01

    Full Text Available The late 19th and early 20th Centuries saw the consolidation in physics of the three main traditions that predominate in discussions of measurement theory. These are: (i the systematic tradition pioneered by Maxwell; (ii the representational tradition pioneered by Campbell; and (iii the operational tradition pioneered by Bridgman (1927. These divergent approaches created uncertainty about the nature of measurement in the physical sciences and provided Stevens (1946 with an opportunity and rationale to, in effect, reinvent the definition of scientific measurement. Stevens appropriated the representational and operational traditions as the sole basis for his definition of measurement, excluding any place for the systematic approach. In committing to Stevens’ path, the psychological sciences were blinded to the advances made in metrology, the establishment of the International System (SI and the standard units contained within this system. These advances were only possible due to the deep conceptual and instrumental connections between the system of physical units and the body of physical theory and laws developed over the preceding centuries. It is argued that if the psychological sciences are to ever achieve equivalent methodological advances, they must bridge this ‘metrological gap’ created by Stevens’ measurement crossroads and understand the ways in which the systematic approach advanced measurement. This means that psychological measurement needs to be de-abstracted, rid of operational rules for numerical assignment and set upon a foundation of quantitative theory, definition and law. In the absence of such theoretical foundations, claims of measurement in the psychological sciences remain a methodological chimera.

  14. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  15. Seminar on Detectors and measurements techniques

    International Nuclear Information System (INIS)

    Holm, E.

    2002-01-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  16. Analysis of Traditional versus Three-Dimensional Augmented Curriculum on Anatomical Learning Outcome Measures

    Science.gov (United States)

    Peterson, Diana Coomes; Mlynarczyk, Gregory S.A.

    2016-01-01

    This study examined whether student learning outcome measures are influenced by the addition of three-dimensional and digital teaching tools to a traditional dissection and lecture learning format curricula. The study was performed in a semester long graduate level course that incorporated both gross anatomy and neuroanatomy curricula. Methods…

  17. Review of lattice measurement techniques at the SLC

    International Nuclear Information System (INIS)

    Barklow, T.; Emma, P.; Krejcik, P.; Walker, N.

    1991-11-01

    A technique is described for reconstructing the first order transport matrix (R) for a given beam line. Emphasis is placed on the rigorous error analysis of the data, and the use of powerful statistical techniques to estimate unknown systematic errors. The application of the technique to the measurement and subsequent correction of the SLC Arcs is briefly described. 5 refs., 4 figs

  18. Trace elements in lake sediments measured by the PIXE technique

    International Nuclear Information System (INIS)

    Gatti, Luciana V.; Mozeto, Antonio A.; Artaxo, Paulo

    1999-01-01

    Lakes are ecosystems where there is a great potential of metal accumulation in sediments due to their depositional characteristics. Total concentration of trace elements was measured on a 50 cm long sediment core from the Infernao Lake, that is an oxbow lake of the Moji-Guacu River basin, in the state of Sao Paulo, Brazil. Dating of the core shows up to 180 yrs old sediment layers. The use of the PIXE technique for elemental analysis avoids the traditional acid digestion procedure common in other techniques. The multielemental characteristic of PIXE allows a simultaneous determination of about 20 elements in the sediment samples, such as, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr, Zr, Ba, and Pb. Average values for the elemental composition were found to be similar to the bulk crustal composition. The lake flooding pattern strongly influences the time series of the elemental profiles. Factor analysis of the elemental variability shows five factors. Two of the factors represent the mineralogical matrix, and others represent the organic component, a factor with lead, and another loaded with chromium. The mineralogical component consists of elements such as, Fe, Al, V, Ti, Mn, Ni, K, Zr, Sr, Cu and Zn. The variability of Si is explained by two distinct factors, because it is influenced by two different sources, aluminum-silicates and quartz, and the effect of inundation are different for each other. The organic matter is strongly associated with calcium, and also bounded with S, Zn, Cu and P. Lead and chromium appears as separated factors, although it is not clear the evidences for their anthropogenic origin. The techniques developed for sample preparation and PIXE analysis was proven as advantageous and provided very good reproducibility and accuracy

  19. From psychotherapy to e-therapy: the integration of traditional techniques and new communication tools in clinical settings.

    Science.gov (United States)

    Castelnuovo, Gianluca; Gaggioli, Andrea; Mantovani, Fabrizia; Riva, Giuseppe

    2003-08-01

    Technology is starting to influence psychological fields. In particular, computer-mediated communication (CMC) is providing new tools that can be fruitfully applied in psychotherapy. These new technologies do not substitute for traditional techniques and approaches but they could be used as integration in the clinical process, enhancing or making easier particular steps of it. This paper focuses on the concept of e-therapy as a new modality of helping people resolve life and relationship issues. It utilizes the power and convenience of the Internet to allow synchronous and asynchronous communication between patient and therapist. It is important to underline that e-therapy is not an alternative treatment, but a resource that can be added to traditional psychotherapy. The paper also discusses how different forms of CMC can be fruitfully applied in psychology and psychotherapy, by evaluating the effectiveness of them in the clinical practice. To enhance the diffusion of e-therapy, further research is needed to evaluate all the pros and cons.

  20. Supply chain performance measurement: the case of the traditional food sector in the EU

    NARCIS (Netherlands)

    Gellynck, X.; Molnar, A.; Aramyan, L.H.

    2008-01-01

    The objective of this study is to develop a sound measurement instrument of traditional food supply chain performance integrating the perspectives of different stakeholders. Therefore first, stakeholders’ goals are generalized via focus groups and individual interviews. Second, stakeholders’ goals

  1. A Comparison of Traditional, Step-Path, and Geostatistical Techniques in the Stability Analysis of a Large Open Pit

    Science.gov (United States)

    Mayer, J. M.; Stead, D.

    2017-04-01

    With the increased drive towards deeper and more complex mine designs, geotechnical engineers are often forced to reconsider traditional deterministic design techniques in favour of probabilistic methods. These alternative techniques allow for the direct quantification of uncertainties within a risk and/or decision analysis framework. However, conventional probabilistic practices typically discretize geological materials into discrete, homogeneous domains, with attributes defined by spatially constant random variables, despite the fact that geological media display inherent heterogeneous spatial characteristics. This research directly simulates this phenomenon using a geostatistical approach, known as sequential Gaussian simulation. The method utilizes the variogram which imposes a degree of controlled spatial heterogeneity on the system. Simulations are constrained using data from the Ok Tedi mine site in Papua New Guinea and designed to randomly vary the geological strength index and uniaxial compressive strength using Monte Carlo techniques. Results suggest that conventional probabilistic techniques have a fundamental limitation compared to geostatistical approaches, as they fail to account for the spatial dependencies inherent to geotechnical datasets. This can result in erroneous model predictions, which are overly conservative when compared to the geostatistical results.

  2. Design techniques for large scale linear measurement systems

    International Nuclear Information System (INIS)

    Candy, J.V.

    1979-03-01

    Techniques to design measurement schemes for systems modeled by large scale linear time invariant systems, i.e., physical systems modeled by a large number (> 5) of ordinary differential equations, are described. The techniques are based on transforming the physical system model to a coordinate system facilitating the design and then transforming back to the original coordinates. An example of a three-stage, four-species, extraction column used in the reprocessing of spent nuclear fuel elements is presented. The basic ideas are briefly discussed in the case of noisy measurements. An example using a plutonium nitrate storage vessel (reprocessing) with measurement uncertainty is also presented

  3. Measuring higher order optical aberrations of the human eye: techniques and applications

    Directory of Open Access Journals (Sweden)

    L. Alberto V. Carvalho

    2002-11-01

    Full Text Available In the present paper we discuss the development of "wave-front", an instrument for determining the lower and higher optical aberrations of the human eye. We also discuss the advantages that such instrumentation and techniques might bring to the ophthalmology professional of the 21st century. By shining a small light spot on the retina of subjects and observing the light that is reflected back from within the eye, we are able to quantitatively determine the amount of lower order aberrations (astigmatism, myopia, hyperopia and higher order aberrations (coma, spherical aberration, etc.. We have measured artificial eyes with calibrated ametropia ranging from +5 to -5 D, with and without 2 D astigmatism with axis at 45º and 90º. We used a device known as the Hartmann-Shack (HS sensor, originally developed for measuring the optical aberrations of optical instruments and general refracting surfaces in astronomical telescopes. The HS sensor sends information to a computer software for decomposition of wave-front aberrations into a set of Zernike polynomials. These polynomials have special mathematical properties and are more suitable in this case than the traditional Seidel polynomials. We have demonstrated that this technique is more precise than conventional autorefraction, with a root mean square error (RMSE of less than 0.1 µm for a 4-mm diameter pupil. In terms of dioptric power this represents an RMSE error of less than 0.04 D and 5º for the axis. This precision is sufficient for customized corneal ablations, among other applications.

  4. Seminar on Detectors and measurements techniques

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. (ed.) [Risoe National Lab., Roskilde (Denmark)

    2002-07-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  5. Measuring caloric response: comparison of different analysis techniques.

    Science.gov (United States)

    Mallinson, A I; Longridge, N S; Pace-Asciak, P; Ngo, R

    2010-01-01

    Electronystagmography (ENG) testing has been supplanted by newer techniques of measuring eye movement with infrared cameras (VNG). Most techniques of quantifying caloric induced nystagmus measure the slow phase velocity in some manner. Although our analysis is carried out by very experienced assessors, some systems have computer algorithms that have been "taught" to locate and quantify maximum responses. We wondered what differences in measurement might show up when measuring calorics using different techniques and systems, the relevance of this being that if there was a change in slow phase velocity between ENG and VNG testing when measuring caloric response, then normative data would have to be changed. There are also some subjective but important aspects of ENG interpretation which comment on the nature of the response (e.g. responses which might be "sporadic" or "scant"). Our experiment compared caloric responses in 100 patients analyzed four different ways. Each caloric was analyzed by our old ENG system, our new VNG system, an inexperienced assessor and the computer algorithm, and data was compared. All four systems made similar measurements but our inexperienced assessor failed to recognize responses as sporadic or scant, and we feel this is a limitation to be kept in mind in the rural setting, as it is an important aspect of assessment in complex patients. Assessment of complex VNGs should be left to an experienced assessor.

  6. A new technique for infrared scintillation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Chiossi, F., E-mail: federico.chiossi@studenti.unipd.it [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Brylew, K. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Borghesani, A.F. [CNISM Unit and Dip. di Fisica e Astronomia, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Braggio, C.; Carugno, G. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy); Drozdowski, W. [Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, 87-100 Torun (Poland); Guarise, M. [Dip. di Fisica e Astronomia and INFN, University of Padua, Via F. Marzolo 8, I-35131 Padova (Italy)

    2017-05-21

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu{sub 0.75}Y{sub 0.25}){sub 3}Al{sub 5}O{sub 12} sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  7. A new technique for infrared scintillation measurements

    International Nuclear Information System (INIS)

    Chiossi, F.; Brylew, K.; Borghesani, A.F.; Braggio, C.; Carugno, G.; Drozdowski, W.; Guarise, M.

    2017-01-01

    We propose a new technique to measure the infrared scintillation light yield of rare earth doped crystals by comparing it to near UV–visible scintillation of a calibrated Pr:(Lu_0_._7_5Y_0_._2_5)_3Al_5O_1_2 sample. As an example, we apply this technique to provide the light yield in visible and infrared range up to 1700 nm of this crystal.

  8. The comparison of aneurysmal necks measured on three dimensional reconstruction images of rotational DSA and those of traditional DSA

    International Nuclear Information System (INIS)

    Wu Chunhong; Chen Zuoquan; Gu Binxian; Zhang Guiyun

    2006-01-01

    Objective: To evaluate the value of three dimensional reconstruction images of rotational DSA on measuring aneurysmal necks and make a comparison with traditional DSA so as to provide more abundant and accurate information for the embolization of aneurysm. Methods: A comparison was made between the measurement of aneurismal necks from 14 cases with traditional DSA examination and a measurement made on three dimensional reconstruction images of the same patients. Results: There was a difference shown in the measurement of the aneurysmal necks between three dimensional reconstruction images of rotational DSA and those of traditional DSA, outcoming with more angles and data on three dimensional reconstruction images. Conclusions: There are more angles of aneurysmal neck can be shown on rotational 3D DSA especially for the demonstration of the largest aneurysmal neck with a directional value for the intervention. (authors)

  9. High-voltage test and measuring techniques

    CERN Document Server

    Hauschild, Wolfgang

    2014-01-01

    It is the intent of this book to combine high-voltage (HV) engineering with HV testing technique and HV measuring technique. Based on long-term experience gained by the authors as lecturer and researcher as well as member in international organizations, such as IEC and CIGRE, the book will reflect the state of the art as well as the future trends in testing and diagnostics of HV equipment to ensure a reliable generation, transmission and distribution of electrical energy. The book is intended not only for experts but also for students in electrical engineering and high-voltage engineering.

  10. The measurement of oxygen in vivo using EPR techniques

    International Nuclear Information System (INIS)

    Swartz, Harold M.; Clarkson, Robert B.

    1998-01-01

    The measurement of pO 2 in vivo using EPR has some features which have already led to very useful applications and this approach is likely to have increasingly wide and effective use. It is based on the effect of oxygen on EPR spectra which provides a sensitive and accurate means to measure pO 2 quantitatively. The development of oxygen-sensitive paramagnetic materials which are very stable, combined with instrumental developments, has been crucial to the in vivo applications of this technique. The physical basis and biological applications of in vivo EPR oximetry are reviewed, with particular emphasis on the use of EPR spectroscopy at 1 GHz using particulate paramagnetic materials for the repetitive and non-invasive measurement of pO 2 in tissues. In vivo EPR has already produced some very useful results which have contributed significantly to solving important biological problems. The characteristics of EPR oximetry which appear to be especially useful are often complementary to existing techniques for measuring oxygen in tissues. These characteristics include the capability of making repeated measurements from the same site, high sensitivity to low levels of oxygen, and non-invasive options. The existing techniques are especially useful for studies in small animals, where the depth of measurements is not an overriding issue. In larger animals and potentially in human subjects, non-invasive techniques seem to be immediately applicable to study phenomena very near the surface (within 10 mm) while invasive techniques have some very promising uses. The clinical uses of EPR oximetry which seem especially promising and likely to be undertaken in the near future are long-term monitoring of the status and response to treatment of peripheral vascular disease and optimizing cancer therapy by enabling it to be modified on the basis of the pO 2 measured in the tumour. (author)

  11. New technique targeting the C5 nerve root proximal to the traditional interscalene sonoanatomical approach is analgesic for outpatient arthroscopic shoulder surgery.

    Science.gov (United States)

    Dobie, Katherine H; Shi, Yaping; Shotwell, Matthew S; Sandberg, Warren S

    2016-11-01

    Regional anesthesia and analgesia for shoulder surgery is most commonly performed via interscalene nerve block. We developed an ultrasound-guided technique that specifically targets the C5 nerve root proximal to the traditional interscalene block and assessed its efficacy for shoulder analgesia. Prospective case series. Vanderbilt Bone and Joint Surgery Center. Patients undergoing shoulder arthroscopy at an ambulatory surgery center. Thirty-five outpatient shoulder arthroscopy patients underwent an analgesic nerve block using a new technique where ultrasound visualization of the C5 nerve root served as the primary target at a level proximal to the traditional interscalene approach. The block was performed with 15mL of 0.5% plain ropivicaine. Post anesthesia care unit pain scores, opioid consumption, hand strength, and duration of block were recorded. Cadaver dissection after injection with methylene blue confirmed that the primary target under ultrasound visualization was the C5 nerve root. Pain scores revealed 97% patients had 0/10 pain at arrival to PACU, with 91% having a pain score of 3/10 or less at discharge from PACU. Medical Research Council (MRC) hand strength mean (SD) score was 4.17 (0.92) on a scale of 1-5. The mean (SD) duration of the block was 13.9 (3.5) hours. A new technique for ultrasound-guided blockade at the level of the C5 nerve root proximal to the level of the traditional interscalene block is efficacious for shoulder post-operative pain control. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Radiometric measurement techniques in metallurgy and foundry technology

    International Nuclear Information System (INIS)

    1990-01-01

    The contributions contain informations concerning the present state and development of radiometric measurement techniques in metallurgy and foundry technology as well as their application to the solution of various problems. The development of isotope techniques is briefly described. Major applications of radiometric equipment in industrial measurement are presented together with the use of isotopes to monitor processes of industrial production. This is followed by a short description of numerous laboratory-scale applications. Another contribution deals with fundamental problems and methods of moisture measurement by neutrons. A complex moisture/density measurement device the practical applicability of which has been tested is described here. Possibilities for clay determination in used-up moulding materials are discussed in a further contribution. The clay content can be determined by real-time radiometric density measurement so that the necessary moisture or addition of fresh sand can be controlled. (orig.) With 20 figs., 9 tabs., 178 refs [de

  13. The Combination of DGT Technique and Traditional Chemical Methods for Evaluation of Cadmium Bioavailability in Contaminated Soils with Organic Amendment

    Science.gov (United States)

    Yao, Yu; Sun, Qin; Wang, Chao; Wang, Pei-Fang; Miao, Ling-Zhan; Ding, Shi-Ming

    2016-01-01

    Organic amendments have been proposed as a means of remediation for Cd-contaminated soils. However, understanding the inhibitory effects of organic materials on metal immobilization requires further research. In this study colza cake, a typical organic amendment material, was investigated in order to elucidate the ability of this material to reduce toxicity of Cd-contaminated soil. Available concentrations of Cd in soils were measured using an in situ diffusive gradients in thin films (DGT) technique in combination with traditional chemical methods, such as HOAc (aqua regia), EDTA (ethylene diamine tetraacetic acid), NaOAc (sodium acetate), CaCl2, and labile Cd in pore water. These results were applied to predict the Cd bioavailability after the addition of colza cake to Cd-contaminated soil. Two commonly grown cash crops, wheat and maize, were selected for Cd accumulation studies, and were found to be sensitive to Cd bioavailability. Results showed that the addition of colza cake may inhibit the growth of wheat and maize. Furthermore, the addition of increasing colza cake doses led to decreasing shoot and root biomass accumulation. However, increasing colza cake doses did lead to the reduction of Cd accumulation in plant tissues, as indicated by the decreasing Cd concentrations in shoots and roots. The labile concentration of Cd obtained by DGT measurements and the traditional chemical extraction methods, showed the clear decrease of Cd with the addition of increasing colza cake doses. All indicators showed significant positive correlations (p soil solution decreased with increasing colza cake doses. This was reflected by the decreases in the ratio (R) value of CDGT to Csol. Our study suggests that the sharp decrease in R values could not only reflect the extremely low capability of labile Cd to be released from its solid phase, but may also be applied to evaluate the abnormal growth of the plants. PMID:27314376

  14. The Combination of DGT Technique and Traditional Chemical Methods for Evaluation of Cadmium Bioavailability in Contaminated Soils with Organic Amendment.

    Science.gov (United States)

    Yao, Yu; Sun, Qin; Wang, Chao; Wang, Pei-Fang; Miao, Ling-Zhan; Ding, Shi-Ming

    2016-06-15

    Organic amendments have been proposed as a means of remediation for Cd-contaminated soils. However, understanding the inhibitory effects of organic materials on metal immobilization requires further research. In this study colza cake, a typical organic amendment material, was investigated in order to elucidate the ability of this material to reduce toxicity of Cd-contaminated soil. Available concentrations of Cd in soils were measured using an in situ diffusive gradients in thin films (DGT) technique in combination with traditional chemical methods, such as HOAc (aqua regia), EDTA (ethylene diamine tetraacetic acid), NaOAc (sodium acetate), CaCl₂, and labile Cd in pore water. These results were applied to predict the Cd bioavailability after the addition of colza cake to Cd-contaminated soil. Two commonly grown cash crops, wheat and maize, were selected for Cd accumulation studies, and were found to be sensitive to Cd bioavailability. Results showed that the addition of colza cake may inhibit the growth of wheat and maize. Furthermore, the addition of increasing colza cake doses led to decreasing shoot and root biomass accumulation. However, increasing colza cake doses did lead to the reduction of Cd accumulation in plant tissues, as indicated by the decreasing Cd concentrations in shoots and roots. The labile concentration of Cd obtained by DGT measurements and the traditional chemical extraction methods, showed the clear decrease of Cd with the addition of increasing colza cake doses. All indicators showed significant positive correlations (p soil solution decreased with increasing colza cake doses. This was reflected by the decreases in the ratio (R) value of CDGT to Csol. Our study suggests that the sharp decrease in R values could not only reflect the extremely low capability of labile Cd to be released from its solid phase, but may also be applied to evaluate the abnormal growth of the plants.

  15. Intercomparison of techniques for the non-invasive measurement of bone mass

    International Nuclear Information System (INIS)

    Cohn, S.H.

    1981-01-01

    A variety of methods are presently available for the non-invasive measurement of bone mass of both normal individuals and patients with metabolic disorders. Chief among these methods are radiographic techniques such as radiogrammetry, photon absorptiometry, computer tomography, Compton scattering and neutron activation analysis. In this review, the salient features of the bone measurement techniques are discussed along with their accuracy and precision. The advantages and disadvantages of the various techniques for measuring bone mass are summarized. Where possible, intercomparisons are made of the various techniques

  16. Prepubertal gonadectomy in cats: different surgical techniques and comparison with gonadectomy at traditional age.

    Science.gov (United States)

    Porters, N; Polis, I; Moons, C; Duchateau, L; Goethals, K; Huyghe, S; de Rooster, H

    2014-09-06

    Feasibility, surgical time and complications of different surgical techniques for prepubertal gonadectomy (PPG; 8-12 weeks of age) in cats were studied and compared to gonadectomy at traditional age (TAG; 6-8 months of age). Kittens were randomly assigned to PPG or TAG. Ovarian pedicle haemostasis for PPG was achieved by ligatures (n=47), vascular clips (n=50), bipolar electrocoagulation (n=50), or pedicle tie (n=50); for TAG (n=34) ligatures were used. In male cats, PPG consisted of closed castration by spermatic cord knot (n=92) or ligature (n=91) while TAG (n=34) was an open castration by spermatic cord knot. A linear (surgical time) and a logistic regression (complications) model were designed. Significance was set at 0.05. For female PPG, clips and coagulation were the fastest procedures; placement of ligatures was most time-consuming. In male PPG, knot placement was significantly faster than ligation. In both sexes, very few intraoperative or wound complications were observed, irrespective of the surgical technique used. Surgical times in females (ligatures) as well as in males (knot) were significantly shorter for PPG than for TAG. PPG was as safe as TAG, yet took less time to perform and did not result in a greater rate of postoperative complications. British Veterinary Association.

  17. Research on the Application of Traditional Embroidery Technology in Modern Jewelry Creation

    Directory of Open Access Journals (Sweden)

    Min Li

    2017-10-01

    Full Text Available Tradition and modernity are the eternal topics of art, especially in the age of information.Efficient mechanical production methods to improve the traditional jewelry production process, which achieved the demand for mass production of jewelry.However, with the development of society and the progress of science and technology,  many traditional arts and crafts are lost.From the traditional culture, this paper analyzes the work of embroidery jewelry by studying the traditional Chinese embroidery culture and technique, summarizes the traditional embroidery technology and modern jewelry design techniques combined approach to guide the creative practice.On the basis of studying the theoretical method of combining traditional embroidery technology with modern jewelry, this paper focuses on the application of traditional embroidery techniques in jewelry creation, inspire the potential of traditional craft, to provide reference for modern jewelry design rich Chinese characteristics and attract the attention of  Chinese jewelry industry and inherit the traditional arts.

  18. A study of the river velocity measurement techniques and analysis methods

    Science.gov (United States)

    Chung Yang, Han; Lun Chiang, Jie

    2013-04-01

    Velocity measurement technology can be traced back to the pitot tube velocity measurement method in the 18th century and today's velocity measurement technology use the acoustic and radar technology, with the Doppler principle developed technology advances, in order to develop the measurement method is more suitable for the measurement of velocity, the purpose is to get a more accurate measurement data and with the surface velocity theory, the maximum velocity theory and the indicator theory to obtain the mean velocity. As the main research direction of this article is to review the literature of the velocity measurement techniques and analysis methods, and to explore the applicability of the measurement method of the velocity measurement instruments, and then to describe the advantages and disadvantages of the different mean velocity profiles analysis method. Adequate review of the references of this study will be able to provide a reference for follow-up study of the velocity measurement. Review velocity measurement literature that different velocity measurement is required to follow the different flow conditions measured be upgraded its accuracy, because each flow rate measurement method has its advantages and disadvantages. Traditional velocity instrument can be used at low flow and RiverRAD microwave radar or imaging technology measurement method may be applied in high flow. In the tidal river can use the ADCP to quickly measure river vertical velocity distribution. In addition, urban rivers may be used the CW radar to set up on the bridge, and wide rivers can be used RiverRAD microwave radar to measure the velocities. Review the relevant literature also found that using Ultrasonic Doppler Current Profiler with the Chiu's theory to the velocity of observing automation work can save manpower and resources to improve measurement accuracy, reduce the risk of measurement, but the great variability of river characteristics in Taiwan and a lot of drifting floating

  19. Fissile and fertile nuclear material measurements using a new differential die-away self-interrogation technique

    International Nuclear Information System (INIS)

    Menlove, H.O.; Menlove, S.H.; Tobin, S.J.

    2009-01-01

    This paper presents a new technique for the measurement of fissile and fertile nuclear materials in spent fuel and plutonium-laden materials such as mixed oxide (MOX) fuel. The technique, called differential die-away self-interrogation, is similar to traditional differential die-away analysis, but it does not require a pulsed neutron generator or pulsed beam accelerator, and it can measure the fertile mass in addition to the fissile mass. The new method uses the spontaneous fission neutrons from 244 Cm in spent fuel and 240 Pu effective neutrons in MOX as the 'pulsed' neutron source, with an average of ∼2.7 neutrons per pulse. The time-correlated neutrons from the spontaneous fission and the subsequent induced fissions are analyzed as a function of time to determine the spontaneous fission rate, the induced fast-neutron fissions, and the induced thermal-neutron fissions. The fissile mass is determined from the induced thermal-neutron fissions that are produced by reflected thermal neutrons that originated from the spontaneous fission reaction. The sensitivity of the fissile mass measurement is enhanced by the use of two measurements, with and without a cadmium liner between the sample and a hydrogenous moderator that surrounds the sample. The fertile mass is determined from the multiplicity analysis of the neutrons detected soon after the initial triggering neutron is detected. The method obtains good sensitivity by the optimal design of two different neutron die-away regions: a short die-away for the neutron detector region and a longer die-away for the sample interrogation region.

  20. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  1. Development of a computational technique to measure cartilage contact area.

    Science.gov (United States)

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Sound Power Estimation by Laser Doppler Vibration Measurement Techniques

    Directory of Open Access Journals (Sweden)

    G.M. Revel

    1998-01-01

    Full Text Available The aim of this paper is to propose simple and quick methods for the determination of the sound power emitted by a vibrating surface, by using non-contact vibration measurement techniques. In order to calculate the acoustic power by vibration data processing, two different approaches are presented. The first is based on the method proposed in the Standard ISO/TR 7849, while the second is based on the superposition theorem. A laser-Doppler scanning vibrometer has been employed for vibration measurements. Laser techniques open up new possibilities in this field because of their high spatial resolution and their non-intrusivity. The technique has been applied here to estimate the acoustic power emitted by a loudspeaker diaphragm. Results have been compared with those from a commercial Boundary Element Method (BEM software and experimentally validated by acoustic intensity measurements. Predicted and experimental results seem to be in agreement (differences lower than 1 dB thus showing that the proposed techniques can be employed as rapid solutions for many practical and industrial applications. Uncertainty sources are addressed and their effect is discussed.

  3. Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors.

    Science.gov (United States)

    Ray, Monalisa; Ray, Asit; Dash, Swagatika; Mishra, Abtar; Achary, K Gopinath; Nayak, Sanghamitra; Singh, Shikha

    2017-01-15

    Fungal diseases in commercially important plants results in a significant reduction in both quality and yield, often leading to the loss of an entire plant. In order to minimize the losses, it is essential to detect and identify the pathogens at an early stage. Early detection and accurate identification of pathogens can control the spread of infection. The present article provides a comprehensive overview of conventional methods, current trends and advances in fungal pathogen detection with an emphasis on biosensors. Traditional techniques are the "gold standard" in fungal detection which relies on symptoms, culture-based, morphological observation and biochemical identifications. In recent times, with the advancement of biotechnology, molecular and immunological approaches have revolutionized fungal disease detection. But the drawback lies in the fact that these methods require specific and expensive equipments. Thus, there is an urgent need for rapid, reliable, sensitive, cost effective and easy to use diagnostic methods for fungal pathogen detection. Biosensors would become a promising and attractive alternative, but they still have to be subjected to some modifications, improvements and proper validation for on-field use. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Measurement techniques for radiological characterization of contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Loos, M

    1996-09-18

    Once the decision is taken to characterize a contaminated site, appropriate measurement techniques must be selected. The choice will depend on the available information, on the nature and extent of the contamination, as well as on available resources (staff and budget). Some techniques are described on the basis of examples of characterization projects (e.g. Olen area in Belgium).

  5. Measurement technique developments for LBE flows

    Energy Technology Data Exchange (ETDEWEB)

    Buchenau, D., E-mail: d.buchenau@fzd.de [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Eckert, S.; Gerbeth, G. [Forschungszentrum Dresden-Rossendorf (FZD), 01314 Dresden (Germany); Stieglitz, R. [Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Dierckx, M. [SCK-CEN, Belgian Nuclear Research Centre, 2400 Mol (Belgium)

    2011-08-31

    We report on the development of measurement techniques for flows in lead-bismuth eutectic alloys (LBE). This paper covers the test results of newly developed contactless flow rate sensors as well as the development and test of the LIDAR technique for operational free surface level detection. The flow rate sensors are based on the flow-induced disturbance of an externally applied AC magnetic field which manifests itself by a modified amplitude or a modified phase of the AC field. Another concept of a force-free contactless flow meter uses a single cylindrical permanent magnet. The electromagnetic torque on the magnet caused by the liquid metal flow sets the magnet into rotation. The operation of those sensors has been demonstrated at liquid metal test loops for which comparative flow rate measurements are available, as well as at the LBE loops THESYS at KIT and WEBEXPIR at SCK-CEN. For the level detection a commercial LIDAR system was successfully tested at the WEBEXPIR facility in Mol and the THEADES loop in Karlsruhe.

  6. A Comparison of Collaborative and Traditional Instruction in Higher Education

    Science.gov (United States)

    Gubera, Chip; Aruguete, Mara S.

    2013-01-01

    Although collaborative instructional techniques have become popular in college courses, it is unclear whether collaborative techniques can replace more traditional instructional methods. We examined the efficacy of collaborative courses (in-class, collaborative activities with no lectures) compared to traditional lecture courses (in-class,…

  7. Signal integrity characterization techniques

    CERN Document Server

    Bogatin, Eric

    2009-01-01

    "Signal Integrity Characterization Techniques" addresses the gap between traditional digital and microwave curricula all while focusing on a practical and intuitive understanding of signal integrity effects within the data transmission channel. High-speed interconnects such as connectors, PCBs, cables, IC packages, and backplanes are critical elements of differential channels that must be designed using today's most powerful analysis and characterization tools.Both measurements and simulation must be done on the device under test, and both activities must yield data that correlates with each other. Most of this book focuses on real-world applications of signal integrity measurements - from backplane for design challenges to error correction techniques to jitter measurement technologies. The authors' approach wisely addresses some of these new high-speed technologies, and it also provides valuable insight into its future direction and will teach the reader valuable lessons on the industry.

  8. Measurement techniques and safety culture in radiation protection -reflections after 37 years of occupation with measuring instruments

    International Nuclear Information System (INIS)

    Maushart, R.

    1994-01-01

    Safety Culture in radiation use and radiation protection implies primarily knowledge and competence of the decision makers. As the measuring techniques are basic for practical radiation protection, only such person can be called competent who has sufficient expertise on measuring techniques, and is able to evaluate its application and results. Safety Culture also implies the readiness to expose errors, and to learn from them. ''Believing in infallibility'' excludes Safety Culture. Therefore, correctly applied measuring technique contributes to recognize weak points early. How far it is used consciously and actively to prevent undesirable developments and exceeding of limits, can be considered outright as a yardstick for a high-ranking safety culture. Safety Culture as a whole, however, needs more than more measuring techniques. It requires its own and adequate Measurement Culture, presupposing also motivation and determination to measure. Therefore, education, training, knowledge and consciousness of safety of the people who are responsible for measurements are decisive for successful radiation protection. (orig.) [de

  9. Demonstration of relatively new electron dosimetry measurement techniques on the Mevatron 80

    International Nuclear Information System (INIS)

    Meyer, J.A.; Palta, J.R.; Hogstrom, K.R.

    1984-01-01

    A comprehensive set of electron dosimetry measurements at 7, 10, 12, 15, and 18 MeV was made on a Mevatron 80. Dosimetry measurements presented include percentage depth dose, dose in the buildup region, field size dependence of output, output at extended distances, lead transmission measurements, and isodose curves. These beam measurements are presented to document the electron beam characteristics of this linear accelerator. Three relatively new dosimetry techniques, which have not been standardly used in the past, are illustrated. One technique determines the depth dose of fields too small to measure. A second technique accurately converts depth dose measured in polystyrene to depth dose in water. A third technique calculates the output at extended distances

  10. Traditional, complementary, and alternative medicine: Focusing on research into traditional Tibetan medicine in China.

    Science.gov (United States)

    Song, Peipei; Xia, Jufeng; Rezeng, Caidan; Tong, Li; Tang, Wei

    2016-07-19

    As a form of traditional, complementary, and alternative medicine (TCAM), traditional Tibetan medicine has developed into a mainstay of medical care in Tibet and has spread from there to China and then to the rest of the world. Thus far, research on traditional Tibetan medicine has focused on the study of the plant and animal sources of traditional medicines, study of the histology of those plants and animals, chemical analysis of traditional medicines, pharmacological study of those medicines, and evaluation of the clinical efficacy of those medicines. A number of papers on traditional Tibetan medicines have been published, providing some evidence of the efficacy of traditional Tibetan medicine. However, many traditional Tibetan medicines have unknown active ingredients, hampering the establishment of drug quality standards, the development of new medicines, commercial production of medicines, and market availability of those medicines. Traditional Tibetan medicine must take several steps to modernize and spread to the rest of the world: the pharmacodynamics of traditional Tibetan medicines need to be determined, the clinical efficacy of those medicines needs to be verified, criteria to evaluate the efficacy of those medicines need to be established in order to guide their clinical use, and efficacious medicines need to be acknowledged by the pharmaceutical market. The components of traditional Tibetan medicine should be studied, traditional Tibetan medicines should be screened for their active ingredients, and techniques should be devised to prepare and manufacture those medicines.

  11. Comparison of non-invasive tear film stability measurement techniques.

    Science.gov (United States)

    Wang, Michael Tm; Murphy, Paul J; Blades, Kenneth J; Craig, Jennifer P

    2018-01-01

    Measurement of tear film stability is commonly used to give an indication of tear film quality but a number of non-invasive techniques exists within the clinical setting. This study sought to compare three non-invasive tear film stability measurement techniques: instrument-mounted wide-field white light clinical interferometry, instrument-mounted keratoscopy and hand-held keratoscopy. Twenty-two subjects were recruited in a prospective, randomised, masked, cross-over study. Tear film break-up or thinning time was measured non-invasively by independent experienced examiners, with each of the three devices, in a randomised order, within an hour. Significant correlation was observed between instrument-mounted interferometric and keratoscopic measurements (p 0.05). Tear film stability values obtained from the hand-held device were significantly shorter and demonstrated narrower spread than the other two instruments (all p 0.05). Good clinical agreement exists between the instrument-mounted interferometric and keratoscopic measurements but not between the hand-held device and either of the instrument-mounted techniques. The results highlight the importance of specifying the instrument employed to record non-invasive tear film stability. © 2017 Optometry Australia.

  12. Characterization of clays used in the fabrication of traditional brazilian ceramic pans: culture and technique

    International Nuclear Information System (INIS)

    Borlini, Monica Castoldi; Aguiar, Mariane Costalonga de; Vieira, Carlos Mauricio Fontes; Monteiro, Sergio Neves

    2009-01-01

    The fabrication process of clay pans in the state of Espirito Santo, southeast of Brazil, is a recognized part of the country's popular culture. In Goiabeiras, a district of the state capital Vitoria, the traditional production of these pans is the source of income for many families. The technique used in these ceramic pans is of indigenous origin, characterized by manual molding, outdoor burning and application of tannin dye. The clay pans are distributed to several Brazilian states and are nowadays conquering the external market. In producing these pans, two types of, yellow and gray, clays are used. The actual source of raw material comes from the deposit of the Mulemba valley, where a concern on the possibility of exhaustion exists. The objective of this study was then to characterize these two types of clays and so contribute to the continuity of traditional clay pan production by knowing the characteristics of the local clays in case of an eventual need for their replacement. Chemical analysis, X-ray diffraction, particle size distribution, plasticity and thermal analysis of the clays were performed. The results showed that the clays are high plasticity kaolinite with considerable amounts of SiO 2 and Al 2 O 3 as well as of alkaline oxides, earth alkaline oxides and Fe 2 O 3 . (author)

  13. Measurements of uranium enrichment by four techniques of gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Tojo, Takao

    1983-12-01

    Measurements of uranium enrichment with the uses of the LMRI (France) UO 2 standards have been made by four techniques of gamma-ray spectrometry, in order to examine measurement characteristics of each technique. The following results were obtained by the three techniques based on the direct determination of the peak area of the 186-keV gamma-rays from 235 U, when the standard sample of 6.297 a/o was used for measuring enrichments ranging from 1.4 a/o to 9.6 a/o ; (i) In a LEPS HP Ge gamma-ray spectrometry, standard deviation of the measured enrichments from the certified ones was 1.4 %, (ii) in a Ge(Li) gamma-ray spectrometry, the standard deviation was 2.0 %, (iii) in a NaI(Tl) gamma-ray spectrometry, the standard deviation was 1.2 %. In the fourth technique, the method of multiple single-channel analyzers, enrichments of 1.4 - 9.6 a/o were measured in the standard deviation of 0.51 %, when the most suitable pairs of standard samples were used for each sample. A part of sources of systematic errors which were caused by each technique adopted was revealed throughout the measurements. And also, it was recognized that the LMRI's values of enrichment were certified precisely, and the UO 2 standards were very useful for enrichment measurements in the four techniques of gamma-ray spectrometry used here. (author)

  14. An intensity-monitoring technique for measuring ellipsometric transients

    NARCIS (Netherlands)

    Droog, J.M.M.; Bootsma, G.A.

    1979-01-01

    Intensity-monitoring techniques make possible the measurement of rapid changes in the ellipsometric parameters. Methods used hitherto have been suitable for measuring slight changes only and require prior knowledge of the Δ and Ψ values for the initial surface. It is shown that larger changes can

  15. Unit vent airflow measurements using a tracer gas technique

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.G. [Union Electric Company, Fulton, MO (United States); Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); Fleming, K.M. [NCS Corp., Columbus, OH (United States)

    1997-08-01

    An alternative method for assessing flowrates that does not depend on point measurements of air flow velocity is the constant tracer injection technique. In this method one injects a tracer gas at a constant rate into a duct and measures the resulting concentration downstream of the injection point. A simple equation derived from the conservation of mass allows calculation of the flowrate at the point of injection. Flowrate data obtained using both a pitot tube and a flow measuring station were compared with tracer gas flowrate measurements in the unit vent duct at the Callaway Nuclear Station during late 1995 and early 1996. These data are presented and discussed with an eye toward obtaining precise flowrate data for release rate calculations. The advantages and disadvantages of the technique are also described. In those test situations for which many flowrate combinations are required, or in large area ducts, a tracer flowrate determination requires fewer man-hours than does a conventional traverse-based technique and does not require knowledge of the duct area. 6 refs., 10 figs., 6 tabs.

  16. Measurement of epithermal neutrons by a coherent demodulation technique

    CERN Document Server

    Horiuchi, N; Takahashi, H; Kobayashi, H; Harasawa, S

    2000-01-01

    Epithermal neutrons have been measured using a neutron dosimeter via a coherent demodulation technique. This dosimeter consists of CsI(Tl)-photodiode scintillation detectors, four of which are coupled to neutron-gamma converting foils of various sizes. Neutron-gamma converting foils of In, Au and Co materials were used, each of which has a large capture cross section which peaks in the epithermal neutron energy region. The type of foil was selected according to the material properties that best correspond to the energy of the epithermal neutrons to be measured. In addition, the proposed technique was applied using Au-foils in order to measure the Cd ratio. The validity of the proposed technique was examined using an sup 2 sup 4 sup 1 Am-Be source placed in a testing stack of polyethylene blocks, and the results were compared with the theoretical values calculated by the Monte Carlo calculation. Finally, the dosimeter was applied for measuring epithermal neutrons and the Cd ratio in an experimental beam-tube o...

  17. Techniques For Measuring Absorption Coefficients In Crystalline Materials

    Science.gov (United States)

    Klein, Philipp H.

    1981-10-01

    Absorption coefficients smaller than 0.001 cm-1 can, with more or less difficulty, be measured by several techniques. With diligence, all methods can be refined to permit measurement of absorption coefficients as small as 0.00001 cm-1. Spectral data are most readily obtained by transmission (spectrophotometric) methods, using multiple internal reflection to increase effective sample length. Emissivity measurements, requiring extreme care in the elimination of detector noise and stray light, nevertheless afford the most accessible spectral data in the 0.0001 to 0.00001 cm-1 range. Single-wavelength informa-tion is most readily obtained with modifications of laser calorimetry. Thermo-couple detection of energy absorbed from a laser beam is convenient, but involves dc amplification techniques and is susceptible to stray-light problems. Photoacoustic detection, using ac methods, tends to diminish errors of these types, but at some expense in experimental complexity. Laser calorimetry has been used for measurements of absorption coefficients as small as 0.000003 cm-1. Both transmission and calorimetric data, taken as functions of intensity, have been used for measurement of nonlinear absorption coefficients.

  18. Technique for measurements of plane waves of uniaxial strain

    International Nuclear Information System (INIS)

    Graham, R.A.

    1977-01-01

    The measurement of plane waves in uniaxial strain, in which large surface areas are loaded and the measurements are restricted to a central region that is not influenced by lateral boundaries, is discussed. Measuring techniques are covered and instruments are discussed

  19. CHINESE LACQUER – SHORT OVERVIEW OF TRADITIONAL TECHNIQUES AND MATERIAL CHARACTERISATION FOR CONSERVATION PURPOSES

    Directory of Open Access Journals (Sweden)

    Xin You LIU

    2014-12-01

    Full Text Available Chinese lacquer (urushi is an ancient natural finishing material obtained from the sap of the lacquer trees (Rhus vernicifera. This has been used for millennia to protect and decorate furniture and various artefacts made of wood or other materials. Lacquered objects are important components of Chinese and world cultural heritage and their conservation imposes a good knowledge and understanding of the material and traditional techniques. This paper presents basic information on the Chinese lacquer as material and lacquering techniques in their historic evolution during different dynasties. The experimental part looked at the physical properties of raw urushi lacquer, respectively aspect, solids content and miscibility with different solvents. A limited compatibility with white spirit as potential thinner was demonstrated. Furthermore, the microstructure of the cured film and characteristic chemical features of raw urushi lacquer as liquid and cured film were investigated. The cured film of raw urushi presents a characteristic microstructural pattern. FTIR spectroscopy revealed a partial oxidation and polymerization following processing by Kuromisation. The further curing accentuated these changes, visible as a decrease of hydroxyl absorptions bands (3400 and 1360cm-1 occurring in parallel with an increase of carbonyl band (1740cm-1 . A strong decrease of the absorption band at 1270cm-1 , which nearly disappears for the cured film, was also observed

  20. Preliminary Studies Of A Phase Modulation Technique For Measuring Chromaticity

    International Nuclear Information System (INIS)

    Tan, C.-Y.

    2006-01-01

    The classical method for measuring chromaticity is to slowly modulate the RF frequency and then measure the betatron tune excursion. The technique that is discussed in this paper instead modulates the phase of the RF and then the chromaticity is obtained by phase demodulating the betatron tune. This technique requires knowledge of the betatron frequency in real time in order for the phase to be demodulated. Fortunately, the Tevatron has a tune tracker based on the phase locked loop principle which fits this requirement. A preliminary study with this technique has showed that it is a promising method for doing continuous chromaticity measurement and raises the possibility of doing successful chromaticity feedback with it

  1. Wholefield displacement measurements using speckle image processing techniques for crash tests

    Science.gov (United States)

    Sriram, P.; Hanagud, S.; Ranson, W. F.

    The digital correlation scheme of Peters et al. (1983) was extended to measure out-of-plane deformations, using a white light projection speckle technique. A simple ray optic theory and the digital correlation scheme are outlined. The technique was applied successfully to measure out-of-plane displacements of initially flat rotorcraft structures (an acrylic circular plate and a steel cantilever beam), using a low cost video camera and a desktop computer. The technique can be extended to measurements of three-dimensional deformations and dynamic deformations.

  2. Use of non-standardised micro-destructive techniques in the characterization of traditional construction materials

    Science.gov (United States)

    Ioannou, Ioannis; Theodoridou, Magdalini; Modestou, Sevasti; Fournari, Revecca; Dagrain, Fabrice

    2013-04-01

    The characterization of material properties and the diagnosis of their state of weathering and conservation are three of the most important steps in the field of cultural heritage preservation. Several standardised experimental methods exist, especially for determining the material properties and their durability. However, they are limited in their application by the required size of test specimens and the controlled laboratory conditions needed to undertake the tests; this is especially true when the materials under study constitute immovable parts of heritage structures. The current use of other advanced methods of analysis, such as imaging techniques, in the aforementioned field of research offers invaluable results. However, these techniques may not always be accessible to the wider research community due to their complex nature and relatively high cost of application. This study presents innovative applications of two recently developed cutting techniques; the portable Drilling Resistance Measuring System (DRMS) and the scratch tool. Both methods are defined as micro-destructive, since they only destroy a very small portion of sample material. The general concept of both methods lies within the forces needed to cut a material by linear (scratch tool) or rotational (DRMS) cutting action; these forces are related to the mechanical properties of the material and the technological parameters applied on the tool. Therefore, for a given testing configuration, the only parameter influencing the forces applied is the strength of the material. These two techniques have been used alongside a series of standardised laboratory tests aiming at the correlation of various stone properties (density, porosity, dynamic elastic modulus and uniaxial compressive strength). The results prove the potential of both techniques in assessing the uniaxial compressive strength of stones. The scratch tool has also been used effectively to estimate the compressive strength of mud bricks. It

  3. A survey on multiproperty measurement techniques of solid materials

    International Nuclear Information System (INIS)

    Matsumoto, Tsuyoshi

    1989-01-01

    The term 'multiproperty measurement' has not as yet been widely used. It is defined as the simultaneous (or continuous) measurement of several properties of material using one sample and one set of equipment. It is highly advantageous to measure several properties of a sample simultaneously. Various aspects of the nature of a substance can be clarified by evaluating its nature in terms of many properties. In particular, advanced techniques for measuring thermal properties of material are needed in the fields of atomic energy industry, aerospace industry, energy industry, electronics industry and academic community. Conventional thermal property measurement techniques which can be applied to multiproperty measurement or minute test sample measurement are outlined focusing on measurement of the thermal conductivity (axial flow method, radial flow method, plate method, unsteady state heating coil method, direct current heating method), specific heat (adiabatic method, drop calorimetry, differential scanning calorimetry, AC calorimetric method, pulse heating method, and laser heating method), thermal diffusivity (laser-flash method), and emissivity (separated black body method, incorporated black body method). (N,K.)

  4. Intercomparison test of various aerosol measurement techniques

    International Nuclear Information System (INIS)

    Cherdron, W.; Hassa, C.; Jordan, S.

    1984-01-01

    At the suggestion of the CONT group (Containment Loading and Response), which is a subgroup of the Safety Working Group of the Fast Reactor Coordinating Committee, a group of experts undertook a comparison of the techniques of sodium aerosol measurement used in various laboratories in the EC. The following laboratories took part in the exercise: CEN-Mol (Belgium), CEA-Cadarache (France), CEA-Fontenay-aux-Roses (France), KfK-Karlsruhe (Federal Republic of Germany), ENEA-Bologna (Italy), and UKAEA-Winfrith (United Kingdom). The objective of the aerosol measurement workshop was to assess the applicability and reliability of specific aerosol measuring instruments. Measurements performed with equipment from the participating laboratories were evaluated using a standard procedure. This enabled an estimate of the accuracy of the experimental data to be provided for the verification of aerosol codes. Thus these results can be used as input for the physical modelling of aerosol behaviour, and the work reported here is a contribution to the definition of the radioactive source term for severe accidents in LMFBRs. The aerosol experts participating in the exercise agreed to concentrate on the techniques of measuring aerosol particle size distributions. The tests were performed at the FAUNA test facility using the aerosol loop. A sodium spray fire, which provides a continuous aerosol source of variable concentration, was produced under open-loop conditions in this facility. Although the primary objective of the workshop was to determine the particle size distributions of the aerosols, measurements of the sodium mass concentration were also made

  5. Evaluation of organic amendment on the effect of cadmium bioavailability in contaminated soils using the DGT technique and traditional methods.

    Science.gov (United States)

    Yao, Yu; Sun, Qin; Wang, Chao; Wang, Pei-Fang; Ding, Shi-Ming

    2017-03-01

    Organic amendments have been widely proposed as a remediation technology for metal-contaminated soils, but there exist controversial results on their effectiveness. In this study, the effect of pig manure addition on cadmium (Cd) bioavailability in Cd-contaminated soils was systematically evaluated by one dynamic, in situ technique of diffusive gradients in thin films (DGT) and four traditional methods based on the equilibrium theory (soil solution concentration and the three commonly used extractants, i.e., acetic acid (HAc), ethylenediamine tetraacetic acid (EDTA), and calcium chloride (CaCl 2 ). Wheat and maize were selected for measurement of plant Cd uptake. The results showed that pig manure addition could promote the growth of two plants, accompanied by increasing biomasses of shoots and roots with increasing doses of pig manure addition. Correspondingly, increasing additions of pig manure reduced plant Cd uptake and accumulation, as indicated by the decreases of Cd concentrations in shoots and roots. The bioavailable concentrations of Cd in Cd-contaminated soils reflected by the DGT technique obviously decreased with increasing doses of pig manure addition, following the same changing trend as plant Cd uptake. Changes in soil solution Cd concentration and extractable Cd by HAc, EDTA, and CaCl 2 in soils were similar to DGT measurement. Meanwhile, the capability of Cd resupply from solid phase to soil solution decreased with increasing additions of pig manure, as reflected by the decreases in the ratio (R) value of C DGT to C sol . Positive correlations were observed between various bioavailable indicators of Cd in soils and Cd concentrations in the tissues of the two plants. These findings provide stronger evidence that pig manure amendment is effective in reducing Cd mobility and bioavailability in soils and it is an ideal organic material for remediation of Cd-contaminated soils.

  6. Double phi-Step theta-Scanning Technique for Spherical Near-Field Antenna Measurements

    DEFF Research Database (Denmark)

    Laitinen, Tommi

    2008-01-01

    Probe-corrected spherical near-field antenna measurements with an arbitrary probe set certain requirements on an applicable scanning technique. The computational complexity of the general high-order probe correction technique for an arbitrary probe, that is based on the Phi scanning, is O(N4...... a specific double Phi-step thetas scanning technique for spherical near-field antenna measurements. This technique not only constitutes an alternative spherical scanning technique, but it also enables formulating an associated probe correction technique for arbitrary probes with the computational complexity...

  7. Mississippi River streamflow measurement techniques at St. Louis, Missouri

    Science.gov (United States)

    Wastson, Chester C.; Holmes, Robert R.; Biedenham, David S.

    2013-01-01

    Streamflow measurement techniques of the Mississippi River at St. Louis have changed through time (1866–present). In addition to different methods used for discrete streamflow measurements, the density and range of discrete measurements used to define the rating curve (stage versus streamflow) have also changed. Several authors have utilized published water surface elevation (stage) and streamflow data to assess changes in the rating curve, which may be attributed to be caused by flood control and/or navigation structures. The purpose of this paper is to provide a thorough review of the available flow measurement data and techniques and to assess how a strict awareness of the limitations of the data may affect previous analyses. It is concluded that the pre-1930s discrete streamflow measurement data are not of sufficient accuracy to be compared with modern streamflow values in establishing long-term trends of river behavior.

  8. A direct-measurement technique for estimating discharge-chamber lifetime. [for ion thrusters

    Science.gov (United States)

    Beattie, J. R.; Garvin, H. L.

    1982-01-01

    The use of short-term measurement techniques for predicting the wearout of ion thrusters resulting from sputter-erosion damage is investigated. The laminar-thin-film technique is found to provide high precision erosion-rate data, although the erosion rates are generally substantially higher than those found during long-term erosion tests, so that the results must be interpreted in a relative sense. A technique for obtaining absolute measurements is developed using a masked-substrate arrangement. This new technique provides a means for estimating the lifetimes of critical discharge-chamber components based on direct measurements of sputter-erosion depths obtained during short-duration (approximately 1 hr) tests. Results obtained using the direct-measurement technique are shown to agree with sputter-erosion depths calculated for the plasma conditions of the test. The direct-measurement approach is found to be applicable to both mercury and argon discharge-plasma environments and will be useful for estimating the lifetimes of inert gas and extended performance mercury ion thrusters currently under development.

  9. Plasma turbulence measured by fast sweep reflectometry on Tore Supra

    International Nuclear Information System (INIS)

    Clairet, F.; Vermare, L.; Leclert, G.

    2004-01-01

    Traditionally devoted to electron density profile measurement we show that fast frequency sweeping reflectometry technique can bring valuable and innovative measurements onto plasma turbulence. While fast frequency sweeping technique is traditionally devoted to electron density radial profile measurements we show in this paper how we can handle the fluctuations of the reflected signal to recover plasma density fluctuation measurements with a high spatial and temporal resolution. Large size turbulence related to magneto-hydrodynamic (MHD) activity and the associated magnetic islands can be detected. The radial profile of the micro-turbulence, which is responsible for plasma anomalous transport processes, is experimentally determined through the fluctuation of the reflected phase signal. (authors)

  10. Plasma turbulence measured by fast sweep reflectometry on Tore Supra

    International Nuclear Information System (INIS)

    Clairet, F.; Vermare, L.; Heuraux, S.; Leclert, G.

    2004-01-01

    Traditionally devoted to electron density profile measurement we show that fast frequency sweeping reflectometry technique can bring valuable and innovative measurements onto plasma turbulence. While fast frequency sweeping technique is traditionally devoted to electron density radial profile measurements we show in this paper how we can handle the fluctuations of the reflected signal to recover plasma density fluctuation measurements with a high spatial and temporal resolution. Large size turbulence related to magneto-hydrodynamic (MHD) activity and the associated magnetic islands can be detected. The radial profile of the micro-turbulence, which is responsible for plasma anomalous transport processes, is experimentally determined through the fluctuation of the reflected phase signal

  11. Analysis of preparation of Chinese traditional medicine based on the fiber fingerprint drop trace

    Science.gov (United States)

    Zhang, Zhilin; Wang, Jialu; Sun, Weimin; Yan, Qi

    2010-11-01

    The purpose of the fiber micro-drop analyzing technique is to measure the characteristics of liquids using optical methods. The fiber fingerprint drop trace (FFDT) is a curve of light intensity vs. time. This curve indicates the forming, growing and dripping processes of the liquid drops. A pair of fibers was used to monitor the dripping process. The FFDTs are acquired and analyzed by a computer. Different liquid samples of many kinds of preparation of Chinese traditional medicines were tested by using the fiber micro-drop sensor in the experiments. The FFDTs of preparation of Chinese traditional medicines with different concentrations were analyzed in different ways. Considering the characters of the FFDTs, a novel method is proposed to measure the different preparation of Chinese traditional medicines and its concentration based on the corresponding relationship of FFDTs and the physical and chemical parameters of the liquids.

  12. Improved Tandem Measurement Techniques for Aerosol Particle Analysis

    Science.gov (United States)

    Rawat, Vivek Kumar

    Non-spherical, chemically inhomogeneous (complex) nanoparticles are encountered in a number of natural and engineered environments, including combustion systems (which produces highly non-spherical aggregates), reactors used in gas-phase materials synthesis of doped or multicomponent materials, and in ambient air. These nanoparticles are often highly diverse in size, composition and shape, and hence require determination of property distribution functions for accurate characterization. This thesis focuses on development of tandem mobility-mass measurement techniques coupled with appropriate data inversion routines to facilitate measurement of two dimensional size-mass distribution functions while correcting for the non-idealities of the instruments. Chapter 1 provides the detailed background and motivation for the studies performed in this thesis. In chapter 2, the development of an inversion routine is described which is employed to determine two dimensional size-mass distribution functions from Differential Mobility Analyzer-Aerosol Particle Mass analyzer tandem measurements. Chapter 3 demonstrates the application of the two dimensional distribution function to compute cumulative mass distribution function and also evaluates the validity of this technique by comparing the calculated total mass concentrations to measured values for a variety of aerosols. In Chapter 4, this tandem measurement technique with the inversion routine is employed to analyze colloidal suspensions. Chapter 5 focuses on application of a transverse modulation ion mobility spectrometer coupled with a mass spectrometer to study the effect of vapor dopants on the mobility shifts of sub 2 nm peptide ion clusters. These mobility shifts are then compared to models based on vapor uptake theories. Finally, in Chapter 6, a conclusion of all the studies performed in this thesis is provided and future avenues of research are discussed.

  13. Neutron measurement techniques for tokamak plasmas

    International Nuclear Information System (INIS)

    Jarvis, O.N.

    1994-01-01

    The present article reviews the neutron measurement techniques that are currently being applied to the study of tokamak plasmas. The range of neutron energies of primary interest is limited to narrow bands around 2.5 and 14 MeV, and the variety of measurements that can be made for plasma diagnostic purposes is also restricted. To characterize the plasma as a neutron source, it is necessary only to measure the total neutron emission, the relative neutron emissivity as a function of position throughout the plasma, and the energy spectra of the emitted neutrons. In principle, such measurements might be expected to be relatively easy. That this is not the case is, in part, attributable to practical problems of accessibility to a harsh environment but is mostly a consequence of the time-scale on which the measurements have to be made and of the wide range of neutron emission intensities that have to be covered: for tokamak studies, the time-scale is of the order of 1 to 100 ms and the neutron intensity ranges from 10 12 to 10 19 s -1 . (author)

  14. Advanced Instrumentation and Measurement Techniques for Near Surface Flows

    Science.gov (United States)

    Cadel, Daniel R.

    The development of aerodynamic boundary layers on wind turbine blades is an important consideration in their performance. It can be quite challenging to replicate full scale conditions in laboratory experiments, and advanced diagnostics become valuable in providing data not available from traditional means. A new variant of Doppler global velocimetry (DGV) known as cross-correlation DGV is developed to measure boundary layer profiles on a wind turbine blade airfoil in the large scale Virginia Tech Stability Wind Tunnel. The instrument provides mean velocity vectors with reduced sensitivity to external conditions, a velocity measurement range from 0 ms-1 to over 3000 ms-1, and an absolute uncertainty. Monte Carlo simulations with synthetic signals reveal that the processing routine approaches the Cramer-Rao lower bound in optimized conditions. A custom probe-beam technique is implanted to eliminate laser flare for measuring boundary layer profiles on a DU96-W-180 wind turbine airfoil model. Agreement is seen with laser Doppler velocimetry data within the uncertainty estimated for the DGV profile. Lessons learned from the near-wall flow diagnostics development were applied to a novel benchmark model problem incorporating the relevant physical mechanisms of the high amplitude periodic turbulent flow experienced by turbine blades in the field. The model problem is developed for experimentally motivated computational model development. A circular cylinder generates a periodic turbulent wake, in which a NACA 63215b airfoil with a chord Reynolds number Rec = 170,000 is embedded for a reduced frequency k = pi f c/V = 1.53. Measurements are performed with particle image velocimetry on the airfoil suction side and in highly magnified planes within the boundary layer. Outside of the viscous region, the Reynolds stress profile is consistent with the prediction of Rapid Distortion Theory (RDT), confirming that the redistribution of normal stresses is an inviscid effect. The

  15. Review of geochemical measurement techniques for a nuclear waste repository in bedded salt

    International Nuclear Information System (INIS)

    Knauss, K.G.; Steinborn, T.L.

    1980-01-01

    A broad, general review is presented of geochemical measurement techniques that can provide data necessary for site selection and repository effectiveness assessment for a radioactive waste repository in bedded salt. The available measurement techniques are organized according to the parameter measured. The list of geochemical parameters include all those measurable geochemical properties of a sample whole values determine the geochemical characteristics or behavior of the system. For each technique, remarks are made pertaining to the operating principles of the measurement instrument and the purpose for which the technique is used. Attention is drawn to areas where further research and development are needed

  16. Protocol of measurement techniques - Project colored solar collectors

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, A.; Chambrier, E. De; Roecker, Ch.; Scartezzini, J.-L.

    2004-08-15

    This illustrated annual report for the Swiss Federal Office of Energy (SFOE) takes a look at work done at the Swiss Federal Institute of Technology in Lausanne, Switzerland, on multi-layer, thin-film interference coatings for solar collector glazing. The correct combinations of refractive indices and film thickness are discussed. The authors state that corresponding multi-layered thin film stacks will have to be realised experimentally in a controlled and reproducible way. New thin film materials are to be tailored to exhibit optimised optical and ageing properties. The development of these coatings is to be based on various measurement techniques, such as spectro-photometry, measurements of total power throughput by means of a solar simulator, spectroscopic ellipsometry, scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The paper provides many examples of typical data and explains which film properties can be inferred from each method and thus describes both the function and purpose of the different measurement techniques.

  17. Measurement of particle velocity using a mutual inductance technique

    International Nuclear Information System (INIS)

    Kerr, Stephen; Kirkpatrick, Douglas; Garden, Steven

    2004-01-01

    Preliminary work on the development of a novel method for the measurement of particle velocity is described. The technique relies on measurement of the mutual inductance between two coaxial coils, one stationary and the other perturbed by the shock wave. The moving coil is the gauge and is deposited on thin film. The method was developed to assist in the study of particle velocities in large samples of porous media surrounding an explosive charge. The technique does not require measurements to be taken in a region of uniform magnetic field and therefore dispenses with the need for Helmholtz coils, the size and cost of which can become prohibitive for large experiments. This has the added advantage of allowing measurements to be taken at points widely dispersed through a sample with relative ease. Measurements of particle velocity in porous media have been compared with those from co-located conventional electromagnetic particle velocity gauges with reasonable agreement

  18. Measurements techniques for transportation noise

    International Nuclear Information System (INIS)

    Brambilla, G.

    2001-01-01

    The noise from transport systems (roads, railways and aircraft) are increasing more and more both in space and in time and, therefore, they are still the major factor responsible for environmental noise pollution. The population exposed to transport noise is also increasing, and the corresponding health effects on people (i.e. annoyance and sleep disturbance) become more severe. Due to this current situation international and national legislation has been issued and implemented to reduce the harmful effects of such noise. This paper describes the techniques prescribed by recent Italian legislation to measure road, railway and aircraft noise. (author)

  19. Limitations on the use of the pulsed-wire field-measuring technique

    International Nuclear Information System (INIS)

    Warren, R.W.

    1987-09-01

    As wigglers become longer and the wavelength of the light they produce becomes shorter, the requirements for magnetic field uniformity and precision of wiggler construction become more severe. Techniques used to measure magnetic fields and to estimate the performance of wigglers are now being pushed to their limits in precision and are generally awkward and time consuming in practice. A new field-error measurement technique has been developed that has the usual advantages of a null technique, demonstrates high sensitivity to field errors, and is rapid and simple to employ. With this technique, it appears practical to use computer control to both measure and correct field errors. In a particularly attractive application, these measuring and correcting steps could be carried out on a daily basis for an operational wiggler, which is mounted under vacuum in its optical cavity. In this way, changes in the fields caused by aging or by thermal or radiation-induced deterioration effects could be rapidly identified and corrections could be instituted without significant interruption to normal operations. The principles and limitations of ths technique will be described and examples given of various implementations that have been examined experimentally. 10 refs., 2 figs., 2 tabs

  20. Modernism and tradition and the traditions of modernism

    Directory of Open Access Journals (Sweden)

    Kros Džonatan

    2006-01-01

    Full Text Available Conventionally, the story of musical modernism has been told in terms of a catastrophic break with the (tonal past and the search for entirely new techniques and modes of expression suitable to a new age. The resulting notion of a single, linear, modernist mainstream (predicated on the basis of a Schoenbergian model of musical progress has served to conceal a more subtle relationship between past and present. Increasingly, it is being recognized that there exist many modernisms and their various identities are forged from a continual renegotiation between past and present, between tradition(s and the avant-garde. This is especially relevant when attempting to discuss the reception of modernism outside central Europe, where the adoption of (Germanic avant-garde attitudes was often interpreted as being "unpatriotic". The case of Great Britain is examined in detail: Harrison Birtwistle’s opera The Mask of Orpheus (1973–83 forms the focus for a wider discussion of modernism within the context of late/post-modern thought.

  1. Outlier Detection Techniques For Wireless Sensor Networks: A Survey

    NARCIS (Netherlands)

    Zhang, Y.; Meratnia, Nirvana; Havinga, Paul J.M.

    2008-01-01

    In the field of wireless sensor networks, measurements that significantly deviate from the normal pattern of sensed data are considered as outliers. The potential sources of outliers include noise and errors, events, and malicious attacks on the network. Traditional outlier detection techniques are

  2. The impact of gender ideologies on men's and women's desire for a traditional or non-traditional partner

    OpenAIRE

    Thomae, M.; Houston, Diane

    2016-01-01

    Two studies examine preferences for a long-term partner who conforms to traditional or non- traditional gender\\ud roles. The studies both demonstrate a link between benevolent sexism and preference for a traditional partner.\\ud However, Study 1 also demonstrates a strong preference among women for a non-traditional partner. We measured\\ud ambivalent sexist ideologies before introducing participants to either a stereotypically traditional or stereotypically non-traditional character of the opp...

  3. The traditional irrigation technique of Lake Garda lemon--houses (Northern Italy)

    Science.gov (United States)

    Barontini, Stefano; Vitale, Nicola; Fausti, Federico; Bettoni, Barbara; Bonati, Sara; Peli, Marco; Pietta, Antonella; Tononi, Marco; Ranzi, Roberto

    2016-04-01

    Between 16th and 19th centuries the North-Western side of Lake Garda was seat of an important district which, at the time of its maximum splendour between 18th and 19th centuries, produced and exported lemons and citrus even toward the Northern Europe and the Russia. The limonaie del Garda (Lake-Garda lemon-houses), the local name of the citrus orchards, were settled on terraces built on steep slopes, with landfill taken from the Eastern side of the lake, and closed by greenhouses during late autumn and winter in order to protect the cultivations. The terraces were built nearby streams, they were South-Eastern exposed and protected by walls from the cold winds. Thanks in fact to the Lake Garda microclimate, lemon trees were not cultivated in pots, as in the typical orangeries of mid-latitudes Europe, but directly in the soil. Here the citrus cultivation technique reached a remarkably high degree of standardisation, with local cultivar as the Madernino or lemon from Maderno, and it involved, as in modern industrial districts, all the surrounding land in order to satisfy the needing of required materials to build the terraces, the walls, the greenhouses and the wooden frames to hold the branches laden with fruits. Due to the great water requirement of lemon trees during summer, which is estimated to range from 150 to 300 ℓ every ten days, the water management played a key role in the cultivation technique. The traditional irrigation technique was standardized as well. During our surveys, we observed that most of the lemon-houses still conserve little stone flumes along the walls upslope to the terraces, with spillways every adult tree, i.e. about every 4 m. The flumes were filled with water taken from an upstream reservoir, built nearby a stream. The spillways were activated with a backwater obtained by means of a sand bag placed within the flume, just downstream to the spillway itself. In order to avoid any excavation, spilled water was driven to the base of each

  4. Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and current

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica

    2012-01-01

    , are in some studies considered the main reasons for the variations. This paper presents an experimental study on the quantitative effect of polarisation time and current on the measured polarisation resistance – and thus the corrosion current density – of passively and actively corroding steel. Two...... electrochemical techniques often used in instruments for on-site corrosion rate measurements are investigated. On passively corroding reinforcement the measured polarisation resistance was for both techniques found to be highly affected by the polarisation time and current and no plateaus at either short or long...... rate for actively corroding steel. For both techniques guidelines for polarisation times and currents are given for (on-site) non-destructive corrosion rate measurements on reinforcement steel in concrete....

  5. Review of geotechnical measurement techniques for a nuclear waste repository in bedded salt

    International Nuclear Information System (INIS)

    1979-12-01

    This report presents a description of geotechnical measurement techniques that can provide the data necessary for safe development - i.e., location, design, construction, operation, decommissioning and abandonment - of a radioactive waste repository in bedded salt. Geotechnical data obtained by a diversity of measurement techniques are required during all phases of respository evolution. The techniques discussed in this report are grouped in the following categories: geologic, geophysical and geodetic; rock mechanics; hydrologic, hydrogeologic and water quality; and thermal. The major contribution of the report is the presentation of extensive tables that provide a review of available measurement techniques for each of these categories. The techniques are also discussed in the text to the extent necessary to describe the measurements and associated instruments, and to evaluate the applicability or limitations of the method. More detailed discussions of thermal phenomena, creep laws and geophysical methods are contained in the appendices; references to detailed explanations of measurement techniques and instrumentation are inluded throughout the report

  6. Review of geotechnical measurement techniques for a nuclear waste repository in bedded salt

    Energy Technology Data Exchange (ETDEWEB)

    1979-12-01

    This report presents a description of geotechnical measurement techniques that can provide the data necessary for safe development - i.e., location, design, construction, operation, decommissioning and abandonment - of a radioactive waste repository in bedded salt. Geotechnical data obtained by a diversity of measurement techniques are required during all phases of respository evolution. The techniques discussed in this report are grouped in the following categories: geologic, geophysical and geodetic; rock mechanics; hydrologic, hydrogeologic and water quality; and thermal. The major contribution of the report is the presentation of extensive tables that provide a review of available measurement techniques for each of these categories. The techniques are also discussed in the text to the extent necessary to describe the measurements and associated instruments, and to evaluate the applicability or limitations of the method. More detailed discussions of thermal phenomena, creep laws and geophysical methods are contained in the appendices; references to detailed explanations of measurement techniques and instrumentation are inluded throughout the report.

  7. Objective techniques for psychological assessment, phase 2. [techniques for measuring human performance during space flight stress

    Science.gov (United States)

    Wortz, E. C.; Saur, A. J.; Nowlis, D. P.; Kendall, M. P.

    1974-01-01

    Results are presented of an initial experiment in a research program designed to develop objective techniques for psychological assessment of individuals and groups participating in long-duration space flights. Specifically examined is the rationale for utilizing measures of attention as an objective assessment technique. Subjects participating in the experiment performed various tasks (eg, playing matrix games which appeared on a display screen along with auditory stimuli). The psychophysiological reactions of the subjects were measured and are given. Previous research of various performance and psychophysiological methods of measuring attention is also discussed. The experiment design (independent and dependent variables) and apparatus (computers and display devices) are described and shown. Conclusions and recommendations are presented.

  8. Stopped-flow technique for transit time measurement in a gas jet

    International Nuclear Information System (INIS)

    Rengan, K.; Lin, J.; Lim, T.; Meyer, R.A.; Harrell, J.

    1985-01-01

    A 'stopped-flow' technique for the measurement of transit time of reaction products in a gas jet is described. The method involved establishing the gas flow through the jet system when the reactor is operating steadily and allowing the pressure to reach equilibrium values. The gas flow is stopped by means of electrically operated valves. The transit-time measurement is achieved by opening the valves and initiating the multiscanning of total activity simultaneously. The value obtained agrees well with the transit time measured by pulsing the reactor. The 'stopped-flow' technique allows on-line measurement of transit time in any gas jet system where the physical transportation time is the major component of the transit time. This technique is especially useful for systems installed in reactors which do not have pulsing capability. (orig.)

  9. Single-borehole techniques

    International Nuclear Information System (INIS)

    Klotz, D.; Moser, H.; Trimborn, P.

    1978-01-01

    Proceeding on the theoretical considerations and on the experience and practice derived from laboratory and field testing, a system consisting of tracer injection units, detector units, measuring probe units and packers is presented, from which the different borehole probes required can be combined. A couple of examples of recent applications shows the position of the Single-Borehole Techniques with respect to the traditional methods used for the measurement of the ground-water flow. A confrontation of the permeabilities of different aquifers consents, both on the basis of the Single-Borehole Techniques as by pumping experiments, the determination of the reliability of the Point-Dilution-Method. The Point-Dilution-Method is giving information about the vertical and horizontal distribution of the permeabilities in an aquifer. By measuring the vertical current in two karst wells, the tributary horizons of a well have been determined, which gave valuable information for the subsequent well construction. Local leakages could be detected by measuring the vertical flow rate through observation wells arranged along a grout curtain erected on both sides of the retaining barrage of the Keban dam. (orig.) [de

  10. Establishment of Measurement Techniques for Sliding Bubble on a Horizontal Tube

    International Nuclear Information System (INIS)

    Kim, Yu-Na Kim; Park, Goon-Cherl; Cho, Hyoung-Kyu

    2015-01-01

    The mechanistic wall boiling model includes many parameters relevant with bubble behaviors, such as the bubble departure diameter, bubble lift-off diameter, bubble waiting time, etc. Although there have been a large number of studies investigating bubble behavior, the subjects of observation are almost bubbles on a plane or vertical tube. Since the bubble motion is highly influenced by the directions of gravitational force and the heating surfaces, it is expected that the bubble behavior on a horizontal tube is largely different from those on the other geometry. The heat exchanger of APR+ has horizontal U-tube configuration installed in a water pool, of which diameter is 50mm. The study aims to establish measurement techniques for sliding bubbles on a horizontal tube. The measurement parameters include the diameter, interface area, volume, and velocity of the bubble. Additionally, in order to analyze the force acting on the bubble, liquid velocity measurement method was proposed. This paper presents the procedure of the measurement; the phase separation technique, 3-D reconstruction technique, and velocity measurement techniques. For visualization of the sliding bubble behavior, bubble and liquid velocity measurement methods were established which use two high speed cameras and a continuous LASER for the PTV and PIV. Three steps for the bubble shape and velocity measurement (the phase separation, 3-D reconstruction, and velocity calculation), were successfully set up and verified. A PIV technique which uses two different time duration for two regions where the velocity difference is huge was proposed and tested. Using these methods, various information regarding a sliding bubble can be obtained such as bubble and liquid velocities, shape, volume, surface area etc

  11. An Indentation Technique for Nanoscale Dynamic Viscoelastic Measurements at Elevated Temperature

    Science.gov (United States)

    Ye, Jiping

    2012-08-01

    Determination of nano/micro-scale viscoelasticity is very important to understand the local rheological behavior and degradation phenomena of multifunctional polymer blend materials. This article reviews research results concerning the development of indentation techniques for making nanoscale dynamic viscoelastic measurements at elevated temperature. In the last decade, we have achieved breakthroughs in noise floor reduction in air and thermal load drift/noise reduction at high temperature before taking on the challenge of nanoscale viscoelastic measurements. A high-temperature indentation technique has been developed that facilitates viscoelastic measurements up to 200 °C in air and 500 °C in a vacuum. During the last year, two viscoelastic measurement methods have been developed by making a breakthrough in suppressing the contact area change at high temperature. One is a sharp-pointed time-dependent nanoindentation technique for microscale application and the other is a spherical time-dependent nanoindentation technique for nanoscale application. In the near future, we expect to lower the thermal load drift and load noise floor even more substantially.

  12. Uncertainty analysis technique for OMEGA Dante measurements

    International Nuclear Information System (INIS)

    May, M. J.; Widmann, K.; Sorce, C.; Park, H.-S.; Schneider, M.

    2010-01-01

    The Dante is an 18 channel x-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g., hohlraums, etc.) at x-ray energies between 50 eV and 10 keV. It is a main diagnostic installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the x-ray diodes, filters and mirrors, and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  13. Uncertainty Analysis Technique for OMEGA Dante Measurements

    International Nuclear Information System (INIS)

    May, M.J.; Widmann, K.; Sorce, C.; Park, H.; Schneider, M.

    2010-01-01

    The Dante is an 18 channel X-ray filtered diode array which records the spectrally and temporally resolved radiation flux from various targets (e.g. hohlraums, etc.) at X-ray energies between 50 eV to 10 keV. It is a main diagnostics installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The absolute flux is determined from the photometric calibration of the X-ray diodes, filters and mirrors and an unfold algorithm. Understanding the errors on this absolute measurement is critical for understanding hohlraum energetic physics. We present a new method for quantifying the uncertainties on the determined flux using a Monte-Carlo parameter variation technique. This technique combines the uncertainties in both the unfold algorithm and the error from the absolute calibration of each channel into a one sigma Gaussian error function. One thousand test voltage sets are created using these error functions and processed by the unfold algorithm to produce individual spectra and fluxes. Statistical methods are applied to the resultant set of fluxes to estimate error bars on the measurements.

  14. Dose measurement techniques for high-energy photon and electron radiation

    International Nuclear Information System (INIS)

    Hohlfeld, K.; Roos, M.

    1992-08-01

    By law the Federal Institute of Physics and Technology (PTB) has been assigned the tasks of representing, preserving and passing on dose units. The analogous continuation of these tasks consists in improving, at the user level, dosimetry techniques in radiation therapy for the benefit of patients. The PTB had an essential share in working out the scientific foundations of dosimetry for high-energy radiation, and the corresponding DIN standards were established with the PTB playing a prominent part. The seminar aimed at presenting the measuring techniques fixed in the new DIN standard 6800 part 2 'Dose measurement techniques according to the probe method - ionization dosimetry', to discuss their physical background and practical implications resulting from them. (orig.) [de

  15. Measurements of He II Thermal Counterflow Using PIV Technique

    International Nuclear Information System (INIS)

    Zhang, T.; Van Sciver, S.W.

    2004-01-01

    Our previous experiments on the measurements of He II thermal counterflow using Particle Image Velocimetry (PIV) have shown that there exists a substantial discrepancy between the measured and theoretical values of normal fluid velocity. It was assumed that this is due to the slip velocity between tracer particles and liquid helium. In the present work, tracer particles with a much smaller mean diameter and a more uniform size distribution were selected in order to reduce the effect of slip velocity, and an improved two phase fluidized bed technique was used to introduce the particles into liquid helium. The normal fluid velocity of thermal counterflow was then measured using the PIV technique at various heat fluxes and bath temperatures. The experimental results, however, still show the existence of discrepancy between PIV measured particle velocities and the theoretical normal fluid velocity. A preliminary explanation of these results is given based on an interaction of tracer particles with the superfluid component in the He II

  16. Photogrammetry: applications of a three-dimensional remote measurement technique

    International Nuclear Information System (INIS)

    Peak, K.

    1988-01-01

    Photogrammetry is defined as the precise art of abstracting measurements from photographic images. Used for many years as a means to produce the world's maps, it has, in recent years, been applied in many engineering environments. The nuclear industry has, in particular, benefitted from the close range applications of photogrammetry. This paper sets out to describe the techniques involved, from the site photography through to the analytical data extraction. It will include a number of examples of where photogrammetry has been used in the nuclear industry as a remote measurement technique, from simple monitoring exercises to the compilation of complex three-dimensional as-built computer models. (author)

  17. Applications Of Measurement Techniques To Develop Small-Diameter, Undersea Fiber Optic Cables

    Science.gov (United States)

    Kamikawa, Neil T.; Nakagawa, Arthur T.

    1984-12-01

    Attenuation, strain, and optical time domain reflectometer (OTDR) measurement techniques were applied successfully in the development of a minimum-diameter, electro-optic sea floor cable. Temperature and pressure models for excess attenuation in polymer coated, graded-index fibers were investigated analytically and experimentally using these techniques in the laboratory. The results were used to select a suitable fiber for the cable. Measurements also were performed on these cables during predeployment and sea-trial testing to verify laboratory results. Application of the measurement techniques and results are summarized in this paper.

  18. Do traditional techniques produce better conventional complete dentures than simplified techniques? A 10-year follow-up of a randomized clinical trial.

    Science.gov (United States)

    Kawai, Yasuhiko; Muarakami, Hiroshi; Feine, Jocelyne S

    2018-07-01

    The use of a simplified method (S) of fabricating complete dentures has been shown to be more cost-efficient than the traditional method (T), and there are no negative consequences that detract from the cost savings in the short term. However, it is not clear whether this remains constant over a decade. The objective of this study was to clarify patients' perspectives and determine any differences between the dentures fabricated with these two different techniques after a decade of use. Edentate individuals participated in a randomized controlled clinical trial and completed a 6-month follow-up from 2001 to 2003 (T group n = 50; S group n = 54). For this 10-year follow-up, they were interviewed by telephone. The assessment included whether the denture was still in use or replaced, the condition of the dentures, patient satisfaction and oral health-related quality of life (OHRQoL). Between and within-group differences and the factors that cause deterioration of oral health-related quality of life (OHRQoL) were determined. Among 54 responders (25 T and 29 S), 14T and 21S kept the original dentures. Both groups were similar in ratings of satisfaction and OHRQoL (maxilla T: 80.0 S: 86.0, p = 0.36; mandibular; T: 66.1 S: 72.3, p = 0.48; OHRQoL T: 111.1 S: 108.5, p = 0.46). Irrespective of fabrication method, discomfort, chewing difficulty and esthetics were the factors that deteriorate OHRQoL (adjusted r = 0.76, p < 0.001). The results indicate that the simplified method remains more cost-efficient than the traditional method over a 10-year period. (IRB approval: A09-E71-12 B McGill University, trial registry: ClinicalTrial.org; NCT02289443). Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Auto-correlation based intelligent technique for complex waveform presentation and measurement

    International Nuclear Information System (INIS)

    Rana, K P S; Singh, R; Sayann, K S

    2009-01-01

    Waveform acquisition and presentation forms the heart of many measurement systems. Particularly, data acquisition and presentation of repeating complex signals like sine sweep and frequency-modulated signals introduces the challenge of waveform time period estimation and live waveform presentation. This paper presents an intelligent technique, for waveform period estimation of both the complex and simple waveforms, based on the normalized auto-correlation method. The proposed technique is demonstrated using LabVIEW based intensive simulations on several simple and complex waveforms. Implementation of the technique is successfully demonstrated using LabVIEW based virtual instrumentation. Sine sweep vibration waveforms are successfully presented and measured for electrodynamic shaker system generated vibrations. The proposed method is also suitable for digital storage oscilloscope (DSO) triggering, for complex signals acquisition and presentation. This intelligence can be embodied into the DSO, making it an intelligent measurement system, catering wide varieties of the waveforms. The proposed technique, simulation results, robustness study and implementation results are presented in this paper.

  20. Concept, characteristics, and applications of important electrical measuring techniques

    International Nuclear Information System (INIS)

    Amberg, C.; Czaika, N.; Andreae, G.

    1978-01-01

    In the field of electrical measuring techniques the investigations were concentrated on the transducers. We investigated the time-temperature behaviour of the following transducers: The weldable, fully encapsulated high temperature strain gauges, inductance and transformer displacement transducers, and weldable capacitive strain transducers with distance sensor. A literatur-review showing the state of techniques reference the influence of nuclear radiation was put together. (orig./HP) [de

  1. Advanced spherical near-field antenna measurement techniques

    DEFF Research Database (Denmark)

    Nielsen, Jeppe Majlund; Pivnenko, Sergey; Breinbjerg, Olav

    2011-01-01

    The DTU-ESA facility has since the 1980es provided highly accurate antenna radiation pattern measurements and gain calibration by use of the probe corrected spherical nearfield technique, both for ESA (the European Space Agency) and other customers and continues to do so. Recent years activities...... and research carried out at the facility are presented in the article. Since 2004 several antenna test facility comparison campaigns were carried out between a number of European antenna measurement facilities. The first campaigns laid the foundation for the later comparisons in providing experience...... in the period 2005–2006 following a series of investigatory measurements and facility updates during 2003–2005. Antenna diagnostics by a SWE-to-PWE transformation presents a case where highly accurate antenna measurements and a plane wave back-projection enable antenna diagnostics by examination...

  2. Evaluation of turbulence measurement techniques from a single Doppler lidar

    Directory of Open Access Journals (Sweden)

    T. A. Bonin

    2017-08-01

    Full Text Available Measurements of turbulence are essential to understand and quantify the transport and dispersal of heat, moisture, momentum, and trace gases within the planetary boundary layer (PBL. Through the years, various techniques to measure turbulence using Doppler lidar observations have been proposed. However, the accuracy of these measurements has rarely been validated against trusted in situ instrumentation. Herein, data from the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA are used to verify Doppler lidar turbulence profiles through comparison with sonic anemometer measurements. For 17 days at the end of the experiment, a single scanning Doppler lidar continuously cycled through different turbulence measurement strategies: velocity–azimuth display (VAD, six-beam scans, and range–height indicators (RHIs with a vertical stare.Measurements of turbulence kinetic energy (TKE, turbulence intensity, and stress velocity from these techniques are compared with sonic anemometer measurements at six heights on a 300 m tower. The six-beam technique is found to generally measure turbulence kinetic energy and turbulence intensity the most accurately at all heights (r2  ≈  0.78, showing little bias in its observations (slope of  ≈  0. 95. Turbulence measurements from the velocity–azimuth display method tended to be biased low near the surface, as large eddies were not captured by the scan. None of the methods evaluated were able to consistently accurately measure the shear velocity (r2 =  0.15–0.17. Each of the scanning strategies assessed had its own strengths and limitations that need to be considered when selecting the method used in future experiments.

  3. Affordable non-traditional source data mining for context assessment to improve distributed fusion system robustness

    Science.gov (United States)

    Bowman, Christopher; Haith, Gary; Steinberg, Alan; Morefield, Charles; Morefield, Michael

    2013-05-01

    This paper describes methods to affordably improve the robustness of distributed fusion systems by opportunistically leveraging non-traditional data sources. Adaptive methods help find relevant data, create models, and characterize the model quality. These methods also can measure the conformity of this non-traditional data with fusion system products including situation modeling and mission impact prediction. Non-traditional data can improve the quantity, quality, availability, timeliness, and diversity of the baseline fusion system sources and therefore can improve prediction and estimation accuracy and robustness at all levels of fusion. Techniques are described that automatically learn to characterize and search non-traditional contextual data to enable operators integrate the data with the high-level fusion systems and ontologies. These techniques apply the extension of the Data Fusion & Resource Management Dual Node Network (DNN) technical architecture at Level 4. The DNN architecture supports effectively assessment and management of the expanded portfolio of data sources, entities of interest, models, and algorithms including data pattern discovery and context conformity. Affordable model-driven and data-driven data mining methods to discover unknown models from non-traditional and `big data' sources are used to automatically learn entity behaviors and correlations with fusion products, [14 and 15]. This paper describes our context assessment software development, and the demonstration of context assessment of non-traditional data to compare to an intelligence surveillance and reconnaissance fusion product based upon an IED POIs workflow.

  4. Noncontact sheet resistance measurement technique for wafer inspection

    Science.gov (United States)

    Kempa, Krzysztof; Rommel, J. Martin; Litovsky, Roman; Becla, Peter; Lojek, Bohumil; Bryson, Frank; Blake, Julian

    1995-12-01

    A new technique, MICROTHERM, has been developed for noncontact sheet resistance measurements of semiconductor wafers. It is based on the application of microwave energy to the wafer, and simultaneous detection of the infrared radiation resulting from ohmic heating. The pattern of the emitted radiation corresponds to the sheet resistance distribution across the wafer. This method is nondestructive, noncontact, and allows for measurements of very small areas (several square microns) of the wafer.

  5. A novel experimental technique of nuclear lifetime measurements

    International Nuclear Information System (INIS)

    Yuminov, O.A.; D'Arrigo, A.; Giardina, G.; Taccone, A.; Vannini, G.; Moroni, A.; Ricci, R.A.; Vannucci, L.

    1995-01-01

    In the present paper a new experimental method to measure nuclear reaction time in the 10 -15 -10 -10 s region is presented. Measurements of the lifetimes of low-lying and long-lived states of 19 F and 20 Ne decaying via α-channel were carried out with the aim of checking the feasibility of the method. The results obtained in this way are compared with the lifetimes known from different techniques. ((orig.))

  6. Effect of the diet traditional and non-traditional on the respiration and excretion in larvae of white shrimp Litopenaeus vannamei

    Directory of Open Access Journals (Sweden)

    María Alejandra Medina-Jasso

    2015-11-01

    Full Text Available Objetive. It was studied the respiration and ammoniacal excretion of zoeas and mysis of Litopenaeus vannamei fed with the diet used traditionally (of microalgae and nauplios of artemia and another alternative (not traditional of microalgae with rotifers. Materials and methods. After four hours the oxygen consumption and ammonia excretion in BOD bottles with 60 larvae (closed respirometers was estimated. The concentrations of O2 and NH4 + were measured with an electrode polarográfico in the first case and with the indophenol blue technique for the second. Results. In zoea, oxygen consumption increased with development and showed statistical differences (p=0.023. In mysis, the oxygen consumption were significance in the traditional diet, whereas no differences were alternative (p=0.003. In both stages for the ammoniacal excretion increased development stage and there were detected statistical difference (p<0.001, although to the diets were not noticed significant differences. Conclusions. A higher energy absorption for zoea (I, II y III what mysis (I, II y III larvae was obtained, this is likely an interaction between rates of respiration and excretion caused by variations in the efficiency of absorption by the larvae. The weights obtained in both larvae were not supplied with differences between diets.

  7. The Islamic Bookbinding Tradition. A Book Archaeological Study

    NARCIS (Netherlands)

    Scheper, Catharina Helena (Karin)

    2014-01-01

    The technique of Islamic bookbinding explores the development of the bookbinding tradition in the Islamic world. Based on an assessment of the collections in the University Library Leiden, the various sewing techniques, constructions and the application of covering materials are described in detail.

  8. Validation of a technique of measurement in vivo of 131I in thyroids

    International Nuclear Information System (INIS)

    Villella, A.M.; Puerta Yepes, N.; Gossio, S.; Papadopulos, S.

    2010-01-01

    The Total Body Counter (TBC) Laboratory of the Nuclear Regulatory Authority, following the institutional initiative of quality assurance in its measurement techniques, has been involved in an accreditation process based on the ISO/IEC 17205:2005 norm. In vivo measurement of 131 I in thyroid has been selected as the first technique in this process, and it is described in this paper. The TBC Laboratory uses for this technique a gamma spectrometry system with a NaI(Tl) detector, calibrated with a neck simulator of the IRD and a certified plane source of 131 I with thyroid form. It has been carried out a validation plan that has permitted the characterization of the 131 I measurement technique, and its uncertainty evaluation. Measurement parameters that affect the uncertainty are discussed and recommendations for the technique optimization are proposed. (authors) [es

  9. An Automated Technique to Construct a Knowledge Base of Traditional Chinese Herbal Medicine for Cancers: An Exploratory Study for Breast Cancer.

    Science.gov (United States)

    Nguyen, Phung Anh; Yang, Hsuan-Chia; Xu, Rong; Li, Yu-Chuan Jack

    2018-01-01

    Traditional Chinese Medicine utilization has rapidly increased worldwide. However, there is limited database provides the information of TCM herbs and diseases. The study aims to identify and evaluate the meaningful associations between TCM herbs and breast cancer by using the association rule mining (ARM) techniques. We employed the ARM techniques for 19.9 million TCM prescriptions by using Taiwan National Health Insurance claim database from 1999 to 2013. 364 TCM herbs-breast cancer associations were derived from those prescriptions and were then filtered by their support of 20. Resulting of 296 associations were evaluated by comparing to a gold-standard that was curated information from Chinese-Wikipedia with the following terms, cancer, tumor, malignant. All 14 TCM herbs-breast cancer associations with their confidence of 1% were valid when compared to gold-standard. For other confidences, the statistical results showed consistently with high precisions. We thus succeed to identify the TCM herbs-breast cancer associations with useful techniques.

  10. Silt fences: An economical technique for measuring hillslope soil erosion

    Science.gov (United States)

    Peter R. Robichaud; Robert E. Brown

    2002-01-01

    Measuring hillslope erosion has historically been a costly, time-consuming practice. An easy to install low-cost technique using silt fences (geotextile fabric) and tipping bucket rain gauges to measure onsite hillslope erosion was developed and tested. Equipment requirements, installation procedures, statistical design, and analysis methods for measuring hillslope...

  11. exploring traditional glass bead making techniques in jewellery

    African Journals Online (AJOL)

    User

    Glass bead making techniques and their mass production will help the individual ... communicate cultural values in a symbolic lan- guage which ..... Surface of most of the new beads were rough ... tourism potential to be developed further to.

  12. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  13. Handbook of microwave component measurements with advanced VNA techniques

    CERN Document Server

    Dunsmore, Joel P

    2012-01-01

    This book provides state-of-the-art coverage for making measurements on RF and Microwave Components, both active and passive. A perfect reference for R&D and Test Engineers, with topics ranging from the best practices for basic measurements, to an in-depth analysis of errors, correction methods, and uncertainty analysis, this book provides everything you need to understand microwave measurements. With primary focus on active and passive measurements using a Vector Network Analyzer, these techniques and analysis are equally applicable to measurements made with Spectrum Analyzers or Noise Figure

  14. How 'Digital' is Traditional Crime?

    NARCIS (Netherlands)

    Montoya, L.; Junger, Marianne; Hartel, Pieter H.

    Measuring how much cybercrime exists is typically done by first defining cybercrime and then quantifying how many cases fit that definition. The drawback is that definitions vary across countries and many cybercrimes are recorded as traditional crimes. An alternative is to keep traditional

  15. An improved visualization-based force-measurement technique for short-duration hypersonic facilities

    Energy Technology Data Exchange (ETDEWEB)

    Laurence, Stuart J.; Karl, Sebastian [Institute of Aerodynamics and Flow Technology, Spacecraft Section, German Aerospace Center (DLR), Goettingen (Germany)

    2010-06-15

    This article is concerned with describing and exploring the limitations of an improved version of a recently proposed visualization-based technique for the measurement of forces and moments in short-duration hypersonic wind tunnels. The technique is based on tracking the motion of a free-flying body over a sequence of high-speed visualizations; while this idea is not new in itself, the use of high-speed digital cinematography combined with a highly accurate least-squares tracking algorithm allows improved results over what have been previously possible with such techniques. The technique precision is estimated through the analysis of artificially constructed and experimental test images, and the resulting error in acceleration measurements is characterized. For wind-tunnel scale models, position measurements to within a few microns are shown to be readily attainable. Image data from two previous experimental studies in the T5 hypervelocity shock tunnel are then reanalyzed with the improved technique: the uncertainty in the mean drag acceleration is shown to be reduced to the order of the flow unsteadiness, 2-3%, and time-resolved acceleration measurements are also shown to be possible. The response time of the technique for the configurations studied is estimated to be {proportional_to}0.5 ms. Comparisons with computations using the DLR TAU code also yield agreement to within the overall experimental uncertainty. Measurement of the pitching moment for blunt geometries still appears challenging, however. (orig.)

  16. Comparison of Student Test Scores in a Coordinate Plane Unit Using Traditional Classroom Techniques Versus Traditional Techniques Coupled with an Ethnomathematics Software at Torch Middle School.

    Science.gov (United States)

    Magallanes, Adriana Moreno

    In response to low achievement in mathematics at a middle school, an ethnomathematic approach was used to teach coordinate planes. Whether there were achievement differences between students taught by the culturally sensitive approach and those taught by a traditional method was studied. Data were collected from the coordinate planes unit…

  17. Measurement of detector neutron energy response using time-of-flight techniques

    International Nuclear Information System (INIS)

    Janee, H.S.

    1973-09-01

    The feasibility of using time-of-flight techniques at the EG and G/AEC linear accelerator for measuring the neutron response of relatively sensitive detectors over the energy range 0.5 to 14 MeV has been demonstrated. The measurement technique is described in detail as are the results of neutron spectrum measurements from beryllium and uranium photoneutron targets. The sensitivity of a fluor photomultiplier LASL detector with a 2- by 1-inch NE-111 scintillator was determined with the two targets, and agreement in the region of overlap was very good. (U.S.)

  18. Improvement of traditional local rice varieties through induced mutations using nuclear techniques

    International Nuclear Information System (INIS)

    Pham Van Ro; Do Huu At

    2001-01-01

    'Improvement of local rice varieties for high yield, resistance to disease and insect pests (brown plant hopper and rice blast) and export quality through induced mutations for the Mekong Delta' started in 1993. After six years, it showed effecting on the field in the MD as well as at the south of Vietnam. TNDB-100 manifest very wide adaptation and yield stable variety. THDB is suitable for deepwater rice region, coastal area, where rice cultivation effected by acid sulphate and salinity conditions. Both varieties are good example for the method. Thank to good Co-operation from extension center from provinces, hundred classes of extension were organized to recommend to the farmers. And thank to the strongly supporting from IAEA so that nearly 400,000 ha of TNDB-100 occupied at the south of Vietnam as well as nearly 15,000 ha of THDB grown in the coastal as well as rainfed lowland rice areas at the South of Vietnam. To continue the rice improvement by this technique, seeds of six traditional local varieties were exposed under different dose of gamma rays to create new mutants. At present day hundred improved breeding lines were selected, a dozen of uniform lines were isolated and entranced the yield trail as well as regional testing program. From these improved varieties would be selected to contribute to the rice cultivation at the south of Vietnam in the next years. (author)

  19. Improvement of traditional local rice varieties through induced mutations using nuclear techniques

    Energy Technology Data Exchange (ETDEWEB)

    Pham Van Ro; Do Huu At [Cuu Long Delta Rice Research Institute (Viet Nam)

    2001-03-01

    'Improvement of local rice varieties for high yield, resistance to disease and insect pests (brown plant hopper and rice blast) and export quality through induced mutations for the Mekong Delta' started in 1993. After six years, it showed effecting on the field in the MD as well as at the south of Vietnam. TNDB-100 manifest very wide adaptation and yield stable variety. THDB is suitable for deepwater rice region, coastal area, where rice cultivation effected by acid sulphate and salinity conditions. Both varieties are good example for the method. Thank to good Co-operation from extension center from provinces, hundred classes of extension were organized to recommend to the farmers. And thank to the strongly supporting from IAEA so that nearly 400,000 ha of TNDB-100 occupied at the south of Vietnam as well as nearly 15,000 ha of THDB grown in the coastal as well as rainfed lowland rice areas at the South of Vietnam. To continue the rice improvement by this technique, seeds of six traditional local varieties were exposed under different dose of gamma rays to create new mutants. At present day hundred improved breeding lines were selected, a dozen of uniform lines were isolated and entranced the yield trail as well as regional testing program. From these improved varieties would be selected to contribute to the rice cultivation at the south of Vietnam in the next years. (author)

  20. A simple measuring technique of surface flow velocity to analyze the behavior of velocity fields in hydraulic engineering applications.

    Science.gov (United States)

    Tellez, Jackson; Gomez, Manuel; Russo, Beniamino; Redondo, Jose M.

    2015-04-01

    An important achievement in hydraulic engineering is the proposal and development of new techniques for the measurement of field velocities in hydraulic problems. The technological advances in digital cameras with high resolution and high speed found in the market, and the advances in digital image processing techniques now provides a tremendous potential to measure and study the behavior of the water surface flows. This technique was applied at the Laboratory of Hydraulics at the Technical University of Catalonia - Barcelona Tech to study the 2D velocity fields in the vicinity of a grate inlet. We used a platform to test grate inlets capacity with dimensions of 5.5 m long and 4 m wide allowing a zone of useful study of 5.5m x 3m, where the width is similar of the urban road lane. The platform allows you to modify the longitudinal slopes from 0% to 10% and transversal slope from 0% to 4%. Flow rates can arrive to 200 l/s. In addition a high resolution camera with 1280 x 1024 pixels resolution with maximum speed of 488 frames per second was used. A novel technique using particle image velocimetry to measure surface flow velocities has been developed and validated with the experimental data from the grate inlets capacity. In this case, the proposed methodology can become a useful tools to understand the velocity fields of the flow approaching the inlet where the traditional measuring equipment have serious problems and limitations. References DigiFlow User Guide. (2012), (June). Russo, B., Gómez, M., & Tellez, J. (2013). Methodology to Estimate the Hydraulic Efficiency of Nontested Continuous Transverse Grates. Journal of Irrigation and Drainage Engineering, 139(10), 864-871. doi:10.1061/(ASCE)IR.1943-4774.0000625 Teresa Vila (1), Jackson Tellez (1), Jesus Maria Sanchez (2), Laura Sotillos (1), Margarita Diez (3, 1), and J., & (1), M. R. (2014). Diffusion in fractal wakes and convective thermoelectric flows. Geophysical Research Abstracts - EGU General Assembly 2014

  1. A TECHNIQUE OF MEASURING OF RESISTANCE OF A GROUNDING DEVICE

    Directory of Open Access Journals (Sweden)

    I.V. Nizhevskyi

    2016-06-01

    Full Text Available Introduction. Measurement of resistance of the grounding device (GD by means of a three-electrode system. This requires not only the right choice of installation locations of measuring electrodes, but also the determination of the point of zero potential. Implementation of these requirements quite time-consuming, and in some cases impossible. Aim. Develop a new technique for measuring the electrical resistance of the GD. Task. The method of measuring the resistance of the GD with the help of a three-electrode setup is necessary to exclude the determination of the point of zero potential. Method. Mathematical modeling and calculation engine. Results. A three-electrode system for measuring the resistance of grounding devices (GD for various purposes is considered. On the basis of Maxwell equations a theoretical substantiation of a new technique for measuring the resistance of any GD of any construction in random soil structure has been proposed. An equation system of the sixth order has been obtained, its solution makes it possible to measure its own mutual resistance in the three-electrode installation with sufficiently high accuracy. Peculiarities of drawing up a calculation scheme of substitution of a three-electrode installation with lumped parameters: self and mutual impedance. Use of the principle of reciprocity eliminates the need of finding a point of zero potential which is a rather difficult task. The technique allows to minimize the spacing of measuring electrodes outside the GD, which substantially reduces the length of wiring of the measurement circuit and increases the «signal-to-interference» ratio and also removes the restrictions on the development of the territory outside the GD being tested. Conclusion. The procedure allows to evaluate the self and mutual impedance grounding all the electrodes in a three-electrode measuring installation of the grounding resistance of the device without finding the point of zero potential.

  2. The Combination of DGT Technique and Traditional Chemical Methods for Evaluation of Cadmium Bioavailability in Contaminated Soils with Organic Amendment

    Directory of Open Access Journals (Sweden)

    Yu Yao

    2016-06-01

    Full Text Available Organic amendments have been proposed as a means of remediation for Cd-contaminated soils. However, understanding the inhibitory effects of organic materials on metal immobilization requires further research. In this study colza cake, a typical organic amendment material, was investigated in order to elucidate the ability of this material to reduce toxicity of Cd-contaminated soil. Available concentrations of Cd in soils were measured using an in situ diffusive gradients in thin films (DGT technique in combination with traditional chemical methods, such as HOAc (aqua regia, EDTA (ethylene diamine tetraacetic acid, NaOAc (sodium acetate, CaCl2, and labile Cd in pore water. These results were applied to predict the Cd bioavailability after the addition of colza cake to Cd-contaminated soil. Two commonly grown cash crops, wheat and maize, were selected for Cd accumulation studies, and were found to be sensitive to Cd bioavailability. Results showed that the addition of colza cake may inhibit the growth of wheat and maize. Furthermore, the addition of increasing colza cake doses led to decreasing shoot and root biomass accumulation. However, increasing colza cake doses did lead to the reduction of Cd accumulation in plant tissues, as indicated by the decreasing Cd concentrations in shoots and roots. The labile concentration of Cd obtained by DGT measurements and the traditional chemical extraction methods, showed the clear decrease of Cd with the addition of increasing colza cake doses. All indicators showed significant positive correlations (p < 0.01 with the accumulation of Cd in plant tissues, however, all of the methods could not reflect plant growth status. Additionally, the capability of Cd to change from solid phase to become available in a soil solution decreased with increasing colza cake doses. This was reflected by the decreases in the ratio (R value of CDGT to Csol. Our study suggests that the sharp decrease in R values could not only

  3. The effect of feeding on CO2 production and energy expenditure in ponies measured by indirect calorimetry and the 13C-bicarbonate technique

    DEFF Research Database (Denmark)

    Jensen, Rasmus Bovbjerg; Kyrstein, T. D.; Junghans, P

    2015-01-01

    Energy expenditure (EE) can be estimated based on respiratory gas exchange measurements, traditionally done in respiration chambers by indirect calorimetry (IC). However, the (13)C-bicarbonate technique ((13)C-BT) might be an alternative minimal invasive method for estimation of CO(2) production...... and EE in the field. In this study, four Shetland ponies were used to explore the effect of feeding on CO(2) production and EE measured simultaneously by IC and (13)C-BT. The ponies were individually housed in respiration chambers and received either a single oral or intravenous (IV) bolus dose of (13)C......-bicarbonate at the three different feeding times. Feeding time affected the CO(2) production (P

  4. Measurements of diversity gain and radiation efficiency of the eleven antenna by using different measurement techniques

    DEFF Research Database (Denmark)

    Yang, Jian; Pivnenko, Sergey; Laitinen, Tommi

    2010-01-01

    This paper presents measurement results of diversity gain and radiation efficiency by using three different measurement techniques: reverberation chamber, spherical near-field anechoic chamber, and multi-probe anechoic chamber. The results are measured over a large 2–8 GHz bandwidth which...

  5. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  6. High precision speed measurement by using interferometric techniques

    International Nuclear Information System (INIS)

    Ávila, M A Rodríguez; Valiente, R Ochoa; Trujillo, L A García

    2015-01-01

    In this work we present the experimental realization of speed measurement by the use of a two wave interferometer and digital signal processing techniques. We built an automated Michelson interferometer and using an He-Ne laser and with the use of the Fast Fourier Transform (FFT) and computer algorithms we derived a method for finding the speed of displacement. We report uncertainties in the order of 2-3 μm/s. with the use of this procedure. This brings the potential of another physical variable measurement like distance or pressure by this indirect measurement method. This approach is compared with an ultrasonic Logger Pro ® speed measurement system, and the results are compared between systems

  7. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Science.gov (United States)

    Kazys, Rymantas; Sliteris, Reimondas; Rekuviene, Regina; Zukauskas, Egidijus; Mazeika, Liudas

    2015-01-01

    An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer) on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C) and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%). PMID:26262619

  8. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions.

    Science.gov (United States)

    Kazys, Rymantas; Sliteris, Reimondas; Rekuviene, Regina; Zukauskas, Egidijus; Mazeika, Liudas

    2015-08-07

    An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer) on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C) and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10(-3) g/cm(3) (1%).

  9. Ultrasonic Technique for Density Measurement of Liquids in Extreme Conditions

    Directory of Open Access Journals (Sweden)

    Rymantas Kazys

    2015-08-01

    Full Text Available An ultrasonic technique, invariant to temperature changes, for a density measurement of different liquids under in situ extreme conditions is presented. The influence of geometry and material parameters of the measurement system (transducer, waveguide, matching layer on measurement accuracy and reliability is analyzed theoretically along with experimental results. The proposed method is based on measurement of the amplitude of the ultrasonic wave, reflected from the interface of the solid/liquid medium under investigation. In order to enhance sensitivity, the use of a quarter wavelength acoustic matching layer is proposed. Therefore, the sensitivity of the measurement system increases significantly. Density measurements quite often must be performed in extreme conditions at high temperature (up to 220 °C and high pressure. In this case, metal waveguides between piezoelectric transducer and the measured liquid are used in order to protect the conventional transducer from the influence of high temperature and to avoid depolarization. The presented ultrasonic density measurement technique is suitable for density measurement in different materials, including liquids and polymer melts in extreme conditions. A new calibration algorithm was proposed. The metrological evaluation of the measurement method was performed. The expanded measurement uncertainty Uρ = 7.4 × 10−3 g/cm3 (1%.

  10. A poloidal field measurement technique

    International Nuclear Information System (INIS)

    Jobes, F.C.

    1989-07-01

    The poloidal field of a tokamak can be determined by observing the light emitted by He + ions injected into the plasma by a perpendicular He 0 beam. These ions will orbit in small circles located where the neutral atom became ionized, and they will remain there for a few microseconds. During this time, some of these ions will also emit light at various spectral lines. The observed spectrum of any of these lines will have a peculiar and very wide shape, and it will be offset (Doppler shifted) with respect to the natural line location. The location and width of the spectral pattern provide independent information about the components of the poloidal field which are parallel and perpendicular to the beam velocity, and this information is local to the point where the light is emitted. For a horizontal beam, these components are b x and b y , respectively. The difference in Doppler shift between two measurement points above one another (at the top and bottom of the beam) is directly proportional to δb x , which in turn is proportional to the transform on that flux surface. Thus, this technique provides a means to measure directly local values of q(r). Simulation studies indicate that accurate measurements can be made in milliseconds. 6 refs., 8 figs

  11. New Technique of Direct Intra-abdominal Pressure Measurement

    Directory of Open Access Journals (Sweden)

    Elena Risin

    2006-10-01

    Conclusion: Direct measurement of intra-abdominal pressure using 14-Fr PVC round drain is a newly described technique that is simple, fast and credible. Future investigation will be needed to confirm the reliability of this method during postoperative follow-up of intra-abdominal pressures in selected patients.

  12. Measurement of hepatic venous pressure gradient revisited: Catheter wedge vs balloon wedge techniques

    Directory of Open Access Journals (Sweden)

    S Timothy Chelliah

    2011-01-01

    Full Text Available Aims: To evaluate the accuracy of measurement of hepatic venous pressure gradient by catheter wedge as compared to balloon wedge (the gold standard. Materials and Methods: Forty-five patients having a clinical diagnosis of intrahepatic portal hypertension were subjected to the two different types of pressure measurements (catheter wedge and balloon wedge during transjugular liver biopsy under fluoroscopic guidance. Statistical Analysis: Spearman′s rank correlation coefficient, Bland-Altman plot for agreement, and single measure intraclass correlation were used for analysis of data. Results: There was a close correlation between the results obtained by both the techniques, with highly significant concordance (P < 0.0001. Hepatic venous pressure gradients as measured by the catheter wedge technique were either equal to or less than those obtained by the balloon wedge technique. Conclusions: The difference in hepatic venous pressure gradients measured by the two techniques is insignificant.

  13. Remote measurement of atmospheric pollutants with laser techniques

    Energy Technology Data Exchange (ETDEWEB)

    Corio, W; Querzola, B; Zanzottera, E

    1979-03-01

    Laser techniques for the remote sensing of atmospheric pollutants are reviewed, with attention given to lidars based on Rayleigh and Mie scattering, the Raman effect, or fluorescent scattering. Emphasis is placed on differential absorption lidars, which rely on Rayleigh or Mie scattering for measurements made in the IR or in the visible-UV range, respectively. A comprehensive air pollution monitoring program based on differential absorption lidars, together with systems using fluorescent backscattering and absorption measurements with topographic backscattering, is described.

  14. SPATIAL ARRANGEMENTS IN TRADITIONAL M'ZABITE HOUSES

    Directory of Open Access Journals (Sweden)

    T BELLAL

    2003-06-01

    Full Text Available This paper aims to study the morphology of M'zabite traditional houses. The study uses the space syntax method. Space syntax proposes a fundamental relationship between the configuration of space in a house and the way that it functions. It is the aim of this research work to test this proposition in an M'zab cross settlement sample. The study particularly focuses on the measure known as " difference factor ". The concept of difference factor has been widely used as a technique to measure the strength of a spatial genotype. As a preliminary conclusion, four characteristic patterns of integration are found, the first one centred on the Ammas N'tadart  [Berber for Wast Eddar], the second on the Ikoumar or arched portico, the third on the stairs, and the last but not the least, is centred on the Tigharghart or upper courtyard.

  15. Improving Our Ability to Assess Land Management and Disturbance by Linking Traditional Ecosystem Measurements with UAV Spectral Analysis

    Science.gov (United States)

    Sutter, L., Jr.; Barron-Gafford, G.; Smith, W. K.; Minor, R. L.; Raub, H.; Jimenez, J. R.; Wolsiffer, S. K.; Escobedo, E. B.; Smith, J.

    2017-12-01

    Drylands are dynamic landscapes of mixed plant functional types that vary in their response to abiotic and biotic drivers of change. Within these regions, woody plant-herbaceous relationships have generally been viewed as negative: woody plants within these ecosystems have been shown to negatively impact herbaceous growth by taking advantage of both deeper stored water and intercepting near surface moisture after precipitation events. There has been a long-invested effort to eliminate woody plants in many areas of the world, and analyzing and assessing land management decisions has historically required high monetary and time inputs. Unfortunately, both management practices and disturbances from fire can leave a very heterogeneous landscape, making assessment of their impacts difficult to assess. This study has attempted to address the effectiveness of two commonly used treatments within woody plant invaded areas, fire and herbicide application, by linking plant physiological measurements with the emerging technology of unmanned aerial vehicle (UAV) spectral analysis. Taking advantage of a USDA-ARS sponsored herbicide treatment in 2016 and the accidental Sawmill Fire of 2017, both within the Santa Rita Experimental Range (SRER) of Southern Arizona, USA, we linked spectral data collected via UAV with ground-based photosynthetic measurements. Given the high repeatability, and both spatial and spectral resolution of low-flying UAV measurements, we found that there are a variety of spectral indices that can be derived and accurately linked with traditional ecological measurements. Results and techniques from this study can be immediately applied to land management plans as well as be improved for other ecological parameters, such as those obtained from long-term study sites containing eddy covariance towers.

  16. Introduction to electronic relaxation in solids: mechanisms and measuring techniques

    International Nuclear Information System (INIS)

    Bonville, P.

    1983-01-01

    The fluctuations of electronic magnetic moments in solids may be investigated by several techniques, either electronic or nuclear. This paper is an introduction of the most frequently encountered paramagnetic relaxation mechanisms (phonons, conduction electrons, exchange or dipolar interactions) in condensed matter, and to the different techniques used for measuring relaxation frequencies: electronic paramagnetic resonance, nuclear magnetic resonance, Moessbauer spectroscopy, inelastic neutron scattering, measurement of longitudinal ac susceptibility and γ-γ perturbed angular correlations. We mainly focus our attention on individual ionic fluctuation spectra, the majority of the experimental work refered to concerning rare earth systems [fr

  17. In vitro evaluation of prosthodontic impression on natural dentition: a comparison between traditional and digital techniques

    Science.gov (United States)

    MALAGUTI, G.; ROSSI, R.; MARZIALI, B.; ESPOSITO, A.; BRUNO, G.; DARIOL, C.; DI FIORE, A.

    2016-01-01

    SUMMARY Objectives The aim of this in vitro study is to evaluate the marginal and internal fit of zirconia core crowns manufactured following different digital and traditional workflows. Methods A 6° taper shoulder prepared abutment tooth was used to produce 20 zirconia core crowns using four different scanning techniques: scanned directly with the extraoral lab scanner, scanned with intraoral scanner, dental impressions using individual dental tray and polyether, dental casts from a polyether impressions. Marginal and internal fits were evaluated with digital photography and the silicone replica method. Results Medium marginal gaps were 76,00 μm ± 28.9 for extraoral lab scanner, 80.50 μm ± 36,2 for intraoral scanner, 88.10 μm ± 34,8 for dental impression scan and 112,4 μm ± 37,2 for dental cast scan. Medium internal gaps were 23.20 μm ± 10,3 for extraoral lab scanner, 16.20 μm ± 8.3 for intraoral scanner, 27.20 μm ± 16.7 for dental impression scan and 30.20 μm ± 12.7 for dental cast scan. Conclusion Internal gap were extensively lower than 70 μm described in literature. Marginal fit was higher than ideal values for all the techniques but within the limit of clinical success. Intraoral scanners obtained the best results for internal gap. PMID:28280529

  18. Air flow measurement techniques applied to noise reduction of a centrifugal blower

    Science.gov (United States)

    Laage, John W.; Armstrong, Ashli J.; Eilers, Daniel J.; Olsen, Michael G.; Mann, J. Adin

    2005-09-01

    The air flow in a centrifugal blower was studied using a variety of flow and sound measurement techniques. The flow measurement techniques employed included Particle Image Velocimetry (PIV), pitot tubes, and a five hole spherical probe. PIV was used to measure instantaneous and ensemble-averaged velocity fields over large area of the outlet duct as a function of fan position, allowing for the visualization of the flow as it leave the fan blades and progressed downstream. The results from the flow measurements were reviewed along side the results of the sound measurements with the goal of identifying sources of noise and inefficiencies in flow performance. The radiated sound power was divided into broadband and tone noise and measures of the flow. The changes in the tone and broadband sound were compared to changes in flow quantities such as the turbulent kinetic energy and Reynolds stress. Results for each method will be presented to demonstrate the strengths of each flow measurement technique as well as their limitations. Finally, the role that each played in identifying noise sources is described.

  19. Center edge angle measurement for hip preservation surgery: technique and caveats.

    Science.gov (United States)

    Anderson, Lucas A; Gililland, Jeremy; Pelt, Christopher; Linford, Samuel; Stoddard, Gregory J; Peters, Christopher L

    2011-01-01

    Anterior and lateral center edge angles have traditionally been used to determine acetabular coverage, and thereby strongly influence the decision to perform acetabular reorientation versus osteochondroplasty in patients with dysplasia and/or femoroacetabular impingement. We propose templating the center of the contained articular femoral head in aspherical hips to provide reliable assessment of acetabular coverage. Digital radiographs of 30 patients with various combinations of femoral and acetabular morphologies were evaluated using 2 methods to identify the anterior center edge angle and lateral center edge angle. The control method used an estimated femoral head center for angle apex. The study technique determined the center of the femoral head by templating the congruent aspect of the femoral head contained by the acetabulum while ignoring the increasing lateral and anterior radius associated with cam deformities. Four readers measured lateral center edge angles on anteroposterior radiographs and anterior center edge angles on false-profile radiographs. Two reads were performed by each reader using both the estimated and the templated methods for a total of 4 reads. Interobserver reliability using the proposed method compared to the standard was much improved for anterior center edge angles (intraclass correlation coefficient of 0.76 vs 0.55) as well as with lateral center edge angles (ICC of 0.80 vs 0.42). Decreased correlation was most commonly associated with abnormal sourcil morphology, posterior wall deficiency combined with calcified labra, and os acetabuli. Including the anterolateral cam deformity in identifying the center of the femoral head for measuring center edge angles leads to an underestimation of acetabular coverage, which may negatively affect hip preservation surgical decision making. Copyright 2011, SLACK Incorporated.

  20. A comparison of methane emission measurements using eddy covariance and manual and automated chamber-based techniques in Tibetan Plateau alpine wetland

    International Nuclear Information System (INIS)

    Yu, Lingfei; Wang, Hao; Wang, Guangshuai; Song, Weimin; Huang, Yao; Li, Sheng-Gong; Liang, Naishen; Tang, Yanhong; He, Jin-Sheng

    2013-01-01

    Comparing of different CH 4 flux measurement techniques allows for the independent evaluation of the performance and reliability of those techniques. We compared three approaches, the traditional discrete Manual Static Chamber (MSC), Continuous Automated Chamber (CAC) and Eddy Covariance (EC) methods of measuring the CH 4 fluxes in an alpine wetland. We found a good agreement among the three methods in the seasonal CH 4 flux patterns, but the diurnal patterns from both the CAC and EC methods differed. While the diurnal CH 4 flux variation from the CAC method was positively correlated with the soil temperature, the diurnal variation from the EC method was closely correlated with the solar radiation and net CO 2 fluxes during the daytime but was correlated with the soil temperature at nighttime. The MSC method showed 25.3% and 7.6% greater CH 4 fluxes than the CAC and EC methods when measured between 09:00 h and 12:00 h, respectively. -- Highlights: •Chamber and eddy covariance methods showed similar seasonal CH 4 flux patterns. •Chamber and eddy covariance methods showed different diurnal CH 4 flux patterns. •Static chamber methods gave a higher magnitude of CH 4 flux. -- The chamber-based methods and the eddy covariance method showed similar seasonal CH 4 flux patterns, but the manual static chamber method resulted in a higher CH 4 flux measurement

  1. Skin friction measurements using He-Ne laser

    Energy Technology Data Exchange (ETDEWEB)

    Choi, S.H. [Hankuk Aviation University Graduate School, Kyonggi-do (Korea, Republic of); Lee, Y. [Hankuk Aviation University, Kyonggi-do (Korea, Republic of)

    1997-07-01

    An experimental study of the skin friction measurement in a turbulent boundary-layer has been carried out. The skin friction measurements are made using the laser interferometer skin friction (LISF) meter, which optically detects the rate of thinning of an oil applied to the test surface. This technique produces reliable skin friction data over a wide range of flow situations up to 3-dimensional complicated flows with separation, where traditional skin friction measurement techniques are not applicable. The present measured data in a turbulent boundary-layer on a flat plate using the LISF technique shows a good comparison with the result from the previous velocity profile techniques, which proves the validity of the present technique. An extensive error analysis is carried out for the present technique yielding an uncertainty of about {+-}8%, which makes them suitable for CFD code validation purposes. Finally the measurements of the skin friction in a separated region after a surface-mounted obstacle are also presented. (author). 19 refs., 12 figs., 3 tabs.

  2. Soil volumetric water content measurements using TDR technique

    Directory of Open Access Journals (Sweden)

    S. Vincenzi

    1996-06-01

    Full Text Available A physical model to measure some hydrological and thermal parameters in soils will to be set up. The vertical profiles of: volumetric water content, matric potential and temperature will be monitored in different soils. The volumetric soil water content is measured by means of the Time Domain Reflectometry (TDR technique. The result of a test to determine experimentally the reproducibility of the volumetric water content measurements is reported together with the methodology and the results of the analysis of the TDR wave forms. The analysis is based on the calculation of the travel time of the TDR signal in the wave guide embedded in the soil.

  3. Applied measuring techniques for the investigation of time-dependent flow phenomena in centrifugal compressors

    International Nuclear Information System (INIS)

    Hass, U.; Haupt, U.; Jansen, M.; Kassens, K.; Knapp, P.; Rautenberg, M.

    1978-01-01

    During the past 10 years new measuring techniques have been developed for the experimental investigation of highly loaded centrifugal compressors. These measuring techniques take into account the time dependency of the fluctuating physical quantities such as pressure, temperature, and velocity. Some key points of these experimental techniques are shown and explained in this paper. An important basis for such measurements is the accurate dynamic calibration of the measuring apparatus. In addition, some problems involved analyzing measured signals are dealt with and pressure measurements and their interpretation are shown. Finally optical, acoustical and vibrational measuring procedures are described which are additionally used for the investigation of non-stationary flow phenomena. (orig.) [de

  4. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg [University Hospital Balgrist and University of Zurich, Radiology, Zuerich (Switzerland); Farshad, Mazda; Espinosa, Norman [University Hospital Balgrist and University of Zurich, Department of Orthopaedic Surgery, Zuerich (Switzerland); Resnick, Donald [University of California San Diego, Department of Radiology, San Diego, CA (United States)

    2013-09-15

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  5. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    International Nuclear Information System (INIS)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg; Farshad, Mazda; Espinosa, Norman; Resnick, Donald

    2013-01-01

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  6. Heterodyne technique for measuring the amplitude and phase transfer functions of an optical modulator

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2002-01-01

    In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From the measure...... the measurements we derive the small-signal alpha-parameter and the time-dependent chirp for different operation conditions.......In this letter, we propose a technique based on heterodyne detection for accurately and simultaneously measuring the amplitude and phase transfer functions of an optical modulator. The technique is used to characterize an InGaAsp multiple quantum-well electroabsorption modulator. From...

  7. International workshop on measuring techniques for liquid metal flows (MTLM). Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, G; Eckert, S [eds.

    1999-11-01

    The international workshop on 'Measuring techniques in liquid metal flows' (MTLM workshop) was organised in frame of the Dresden 'Innovationskolleg Magnetofluiddynamik'. The subject of the MTLM workshop was limited to methods to determine physical flow quantities such as velocity, pressure, void fraction, inclusion properties, crystallisation fronts etc. The present proceedings contain abstracts and viewgraphs of the oral presentations. During the last decades numerical simulations have become an important tool in industry and research to study the structure of flows and the properties of heat and mass transfer. However, in case of liquid metal flows there exists a significant problem to validate the codes with experimental data due to the lack of available measuring techniques. Due to the material properties (opaque, hot, chemical aggressive) the measurement of flow quantities is much more delicate in liquid metals compared to ordinary water flows. The generalisation of results obtained by means of water models to real liquid metal flows has often to be considered as difficult due to the problems to meet the actual values of n0n-dimensional flow parameters (Re, Pr, Gr, Ha, etc.). Moreover, a strong need has to be noted to make measuring techniques available tomonitor and to control flow processes in real industrial facilities. The objectives of the MTLM workshop were to: Review of existing information on a available techniques and experiences about the use in liquid metal flows, initiate a discussion between developers and potential users with respect to the actual need of information about the flow structure as well as the capabilities of existing and developing measuring techniques. Explore opportunities for co-operative R and D projects to expedite new developments and results, to share expertise and resources. (orig.)

  8. International workshop on measuring techniques for liquid metal flows (MTLM). Abstracts

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, G.; Eckert, S. [eds.

    1999-11-01

    The international workshop on 'Measuring techniques in liquid metal flows' (MTLM workshop) was organised in frame of the Dresden 'Innovationskolleg Magnetofluiddynamik'. The subject of the MTLM workshop was limited to methods to determine physical flow quantities such as velocity, pressure, void fraction, inclusion properties, crystallisation fronts etc. The present proceedings contain abstracts and viewgraphs of the oral presentations. During the last decades numerical simulations have become an important tool in industry and research to study the structure of flows and the properties of heat and mass transfer. However, in case of liquid metal flows there exists a significant problem to validate the codes with experimental data due to the lack of available measuring techniques. Due to the material properties (opaque, hot, chemical aggressive) the measurement of flow quantities is much more delicate in liquid metals compared to ordinary water flows. The generalisation of results obtained by means of water models to real liquid metal flows has often to be considered as difficult due to the problems to meet the actual values of n0n-dimensional flow parameters (Re, Pr, Gr, Ha, etc.). Moreover, a strong need has to be noted to make measuring techniques available tomonitor and to control flow processes in real industrial facilities. The objectives of the MTLM workshop were to: Review of existing information on a available techniques and experiences about the use in liquid metal flows, initiate a discussion between developers and potential users with respect to the actual need of information about the flow structure as well as the capabilities of existing and developing measuring techniques. Explore opportunities for co-operative R and D projects to expedite new developments and results, to share expertise and resources. (orig.)

  9. Measurement Techniques for Radon in Mines, Dwellings and the Environment

    International Nuclear Information System (INIS)

    Snihs, J.O.

    1983-06-01

    Definitions and units appropriate for radon and radon daughters are given. The principle methods of detection are ionization chamber, scintillation technique, nuclear track detector, thermoluminescent discs and alpha spectrometry. The activity concentration is determined by grab sampling and subsequent measurement, frequent or continuous grab sampling and measurement and continuous sampling and long time integrated measurement. Sampling and measurement strategies for mines, dwellings and the environment are discussed. (author)

  10. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, R; Moreno, I; Araujo, C [Facultad de Fisica, Universidad Autonoma de Zacatecas, Calz. Solidaridad Esquina Paseo de la Bufa s/n, C. P. 98060, Zacatecas, Zac. (Mexico); Marin, E, E-mail: emarin63@yahoo.e, E-mail: emarinm@ipn.m [Centro de Investigacion en Ciencia Aplicada y TecnologIa Avanzada, Instituto Politecnico Nacional, LegarIa 694, Colonia Irrigacion, C. P. 11500, Mexico D. F. (Mexico)

    2010-06-09

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  11. Electropyroelectric technique for measurement of the thermal effusivity of liquids

    International Nuclear Information System (INIS)

    Ivanov, R; Moreno, I; Araujo, C; Marin, E

    2010-01-01

    The photopyroelectric method has been recognized as a reliable and useful tool for the measurement of the thermal properties of condensed matter samples. Usually the photothermal signal is generated using intensity modulated light beams, whose amplitudes are difficult to maintain stable. In this paper we describe a variant of this technique that uses amplitude modulated electrical current as excitation source, via Joule heating of the metal contact on one side of the pyroelectric sensor. The possibilities of this method, called by us the electropyroelectric technique, for thermal effusivity measurements of liquid samples are shown using test samples of distilled water, ethanol and glycerine. The results obtained for this parameter agree well with the values reported in the literature. Our measurement uncertainties are about 3%, a fact that opens several possible applications.

  12. Slow neutron mapping technique for level interface measurement

    Science.gov (United States)

    Zain, R. M.; Ithnin, H.; Razali, A. M.; Yusof, N. H. M.; Mustapha, I.; Yahya, R.; Othman, N.; Rahman, M. F. A.

    2017-01-01

    Modern industrial plant operations often require accurate level measurement of process liquids in production and storage vessels. A variety of advanced level indicators are commercially available to meet the demand, but these may not suit specific need of situations. The neutron backscatter technique is exceptionally useful for occasional and routine determination, particularly in situations such as pressure vessel with wall thickness up to 10 cm, toxic and corrosive chemical in sealed containers, liquid petroleum gas storage vessels. In level measurement, high energy neutrons from 241Am-Be radioactive source are beamed onto a vessel. Fast neutrons are slowed down mostly by collision with hydrogen atoms of material inside the vessel. Parts of thermal neutron are bounced back towards the source. By placing a thermal detector next to the source, these backscatter neutrons can be measured. The number of backscattered neutrons is directly proportional to the concentration of the hydrogen atoms in front of the neutron detector. As the source and detector moved by the matrix around the side of the vessel, interfaces can be determined as long as it involves a change in hydrogen atom concentration. This paper presents the slow neutron mapping technique to indicate level interface of a test vessel.

  13. A cable-free impedance and gain measurement technique for electrically small antennas

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Zhang, Jiaying; Breinbjerg, Olav

    2010-01-01

    are represented in terms of spherical wave expansions (SWEs), and the propagation is accounted for by a transmission formula. In this paper the measurement results by the proposed technique will be presented for several AUTs, including a standard gain horn antenna, a monopole antenna, and an electrically small......Impedance and gain measurements for electrically small antennas represent a great challenge due to influences of the feeding cable. The leaking current along the cable and scattering effects are two main issues caused by the feed line. In this paper, a novel cable-free antenna impedance and gain...... measurement technique for electrically small antennas is proposed. The antenna properties are extracted by measuring the signal scattered by the antenna under test (AUT), when it is loaded with three known loads. The technique is based on a rigorous electromagnetic model where the probe and AUT...

  14. Gamma ray densitometry techniques for measuring of volume fractions

    International Nuclear Information System (INIS)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques

    2015-01-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  15. Gamma ray densitometry techniques for measuring of volume fractions

    Energy Technology Data Exchange (ETDEWEB)

    Affonso, Renato Raoni Werneck; Silva, Ademir Xavier da; Salgado, Cesar Marques, E-mail: raoniwa@yahoo.com.br, E-mail: ademir@nuclear.ufrj.br, E-mail: otero@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Knowledge of the volume fraction in a multiphase flow is of key importance in predicting the performance of many systems and processes. It is therefore an important parameter to characterize such flows. In the context of nuclear techniques, the gamma ray densitometry is promising and this is due to its non-invasive characteristics and very reliable results. It is used in several applications for multiphase flows (water-oil-air), which are employed tools such as: computational fluid dynamics, artificial neural networks and statistical methods of radiation transport, such as the Monte Carlo method. Based on the gamma radiation techniques for measurements of volume fractions, the aim of this paper is to present several techniques developed for this purpose. (author)

  16. Use of variance techniques to measure dry air-surface exchange rates

    Science.gov (United States)

    Wesely, M. L.

    1988-07-01

    The variances of fluctuations of scalar quantities can be measured and interpreted to yield indirect estimates of their vertical fluxes in the atmospheric surface layer. Strong correlations among scalar fluctuations indicate a similarity of transfer mechanisms, which is utilized in some of the variance techniques. The ratios of the standard deviations of two scalar quantities, for example, can be used to estimate the flux of one if the flux of the other is measured, without knowledge of atmospheric stability. This is akin to a modified Bowen ratio approach. Other methods such as the normalized standard-deviation technique and the correlation-coefficient technique can be utilized effectively if atmospheric stability is evaluated and certain semi-empirical functions are known. In these cases, iterative calculations involving measured variances of fluctuations of temperature and vertical wind velocity can be used in place of direct flux measurements. For a chemical sensor whose output is contaminated by non-atmospheric noise, covariances with fluctuations of scalar quantities measured with a very good signal-to-noise ratio can be used to extract the needed standard deviation. Field measurements have shown that many of these approaches are successful for gases such as ozone and sulfur dioxide, as well as for temperature and water vapor, and could be extended to other trace substances. In humid areas, it appears that water vapor fluctuations often have a higher degree of correlation to fluctuations of other trace gases than do temperature fluctuations; this makes water vapor a more reliable companion or “reference” scalar. These techniques provide some reliable research approaches but, for routine or operational measurement, they are limited by the need for fast-response sensors. Also, all variance approaches require some independent means to estimate the direction of the flux.

  17. High voltage test techniques

    CERN Document Server

    Kind, Dieter

    2001-01-01

    The second edition of High Voltage Test Techniques has been completely revised. The present revision takes into account the latest international developments in High Voltage and Measurement technology, making it an essential reference for engineers in the testing field.High Voltage Technology belongs to the traditional area of Electrical Engineering. However, this is not to say that the area has stood still. New insulating materials, computing methods and voltage levels repeatedly pose new problems or open up methods of solution; electromagnetic compatibility (EMC) or components and systems al

  18. Validation of a laser-assisted wound measurement device in a wound healing model.

    Science.gov (United States)

    Constantine, Ryan S; Bills, Jessica D; Lavery, Lawrence A; Davis, Kathryn E

    2016-10-01

    In the treatment and monitoring of a diabetic or chronic wound, accurate and repeatable measurement of the wound provides indispensable data for the patient's medical record. This study aims to measure the accuracy of the laser-assisted wound measurement (LAWM) device against traditional methods in the measurement of area, depth and volume. We measured four 'healing' wounds in a Play-Doh(®) -based model over five subsequent states of wound healing progression in which the model was irregularly filled in to replicate the healing process. We evaluated the LAWM device against traditional methods including digital photograph assessment with National Institutes of Health ImageJ software, measurements of depth with a ruler and weight-to-volume assessment with dental paste. Statistical analyses included analysis of variance (ANOVA) and paired t-tests. We demonstrate that there are significantly different and nearly statistically significant differences between traditional ruler depth measurement and LAWM device measurement, but there are no statistically significant differences in area measurement. Volume measurements were found to be significantly different in two of the wounds. Rate of percentage change was analysed for volume and depth in the wound healing model, and the LAWM device was not significantly different than the traditional measurement technique. While occasionally inaccurate in its absolute measurement, the LAWM device is a useful tool in the clinician's arsenal as it reliably measures rate of percentage change in depth and volume and offers a potentially aseptic alternative to traditional measurement techniques. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  19. Description and Evaluation of a Measurement Technique for Assessment of Performing Gender

    Science.gov (United States)

    Harris, Kathleen Mullan; Halpern, Carolyn Tucker

    2016-01-01

    The influence of masculinity and femininity on behaviors and outcomes has been extensively studied in social science research using various measurement strategies. In the present paper, we describe and evaluate a measurement technique that uses existing survey items to capture the extent to which an individual behaves similarly to their same-gender peers. We use data from the first four waves of The National Longitudinal Study of Adolescent to Adult Health (Add Health), a nationally representative sample of adolescents (age 12–18) in the United States who were re-interviewed at ages 13–19, 18–26, and 24–32. We estimate split-half reliability and provide evidence that supports the validity of this measurement technique. We demonstrate that the resulting measure does not perform as a trait measure and is associated with involvement in violent fights, a pattern consistent with theory and empirical findings. This measurement technique represents a novel approach for gender researchers with the potential for expanding our current knowledge base. PMID:28630528

  20. Measurement techniques and instruments suitable for life-prediction testing of photovoltaic arrays. Interim report

    Energy Technology Data Exchange (ETDEWEB)

    Noel, G.T.; Sliemers, F.A.; Deringer, G.C.; Wood, V.E.; Wilkes, K.E.; Gaines, G.B.; Carmichael, D.C.

    1978-01-15

    The validation of a service life of 20 years for low-cost photovoltaic arrays must be accomplished through accelerated life-prediction tests. A methodology for such tests has been developed in a preceding study. The results discussed consist of the initial identification and assessment of all known measurement techniques and instruments that might be used in these life-prediction tests. Array failure modes, relevant materials property changes, and primary degradation mechanisms are discussed as a prerequisite to identifying suitable measurement techniques and instruments. Candidate techniques and instruments are identified on the basis of extensive reviews of published and unpublished information. These methods are organized in six measurement categories--chemical, electrical, optical, thermal, mechanical, and ''other physicals''. Using specified evaluation criteria, the most promising techniques and instruments for use in life-prediction tests of arrays are then selected. These recommended techniques and their characteristics are described. Recommendations are made regarding establishment of the adequacy, particularly with respect to precision, of the more fully developed techniques for this application, and regarding the experimental evaluation of promising developmental techniques. Measurement needs not satisfied by presently available techniques/instruments are also identified.

  1. Comparative CO2 flux measurements by eddy covariance technique using open- and closed-path gas analysers over the equatorial Pacific Ocean

    Directory of Open Access Journals (Sweden)

    Fumiyoshi Kondo

    2012-04-01

    Full Text Available Direct comparison of air–sea CO2 fluxes by open-path eddy covariance (OPEC and closed-path eddy covariance (CPEC techniques was carried out over the equatorial Pacific Ocean. Previous studies over oceans have shown that the CO2 flux by OPEC was larger than the bulk CO2 flux using the gas transfer velocity estimated by the mass balance technique, while the CO2 flux by CPEC agreed with the bulk CO2 flux. We investigated a traditional conflict between the CO2 flux by the eddy covariance technique and the bulk CO2 flux, and whether the CO2 fluctuation attenuated using the closed-path analyser can be measured with sufficient time responses to resolve small CO2 flux over oceans. Our results showed that the closed-path analyser using a short sampling tube and a high volume air pump can be used to measure the small CO2 fluctuation over the ocean. Further, the underestimated CO2 flux by CPEC due to the attenuated fluctuation can be corrected by the bandpass covariance method; its contribution was almost identical to that of H2O flux. The CO2 flux by CPEC agreed with the total CO2 flux by OPEC with density correction; however, both of them are one order of magnitude larger than the bulk CO2 flux.

  2. The Cervical Dystonia Impact Profile (CDIP-58: Can a Rasch developed patient reported outcome measure satisfy traditional psychometric criteria?

    Directory of Open Access Journals (Sweden)

    Bhatia Kailash P

    2008-08-01

    Full Text Available Abstract Background The United States Food and Drug Administration (FDA are currently producing guidelines for the scientific adequacy of patient reported outcome measures (PROMs in clinical trials, which will have implications for the selection of scales used in future clinical trials. In this study, we examine how the Cervical Dystonia Impact Profile (CDIP-58, a rigorous Rasch measurement developed neurologic PROM, stands up to traditional psychometric criteria for three reasons: 1 provide traditional psychometric evidence for the CDIP-58 in line with proposed FDA guidelines; 2 enable researchers and clinicians to compare it with existing dystonia PROMs; and 3 help researchers and clinicians bridge the knowledge gap between old and new methods of reliability and validity testing. Methods We evaluated traditional psychometric properties of data quality, scaling assumptions, targeting, reliability and validity in a group of 391 people with CD. The main outcome measures used were the CDIP-58, Medical Outcome Study Short Form-36, the 28-item General Health Questionnaire, and Hospital and Anxiety and Depression Scale. Results A total of 391 people returned completed questionnaires (corrected response rate 87%. Analyses showed: 1 data quality was high (low missing data ≤ 4%, subscale scores could be computed for > 96% of the sample; 2 item groupings passed tests for scaling assumptions; 3 good targeting (except for the Sleep subscale, ceiling effect = 27%; 4 good reliability (Cronbach's alpha ≥ 0.92, test-retest intraclass correlations ≥ 0.83; and 5 validity was supported. Conclusion This study has shown that new psychometric methods can produce a PROM that stands up to traditional criteria and supports the clinical advantages of Rasch analysis.

  3. Fixture-abutment connection surface and micro-gap measurements by 3D micro-tomographic technique analysis

    Directory of Open Access Journals (Sweden)

    Deborah Meleo

    2012-01-01

    Full Text Available X-ray micro-tomography (micro-CT is a miniaturized form of conventional computed axial tomography (CAT able to investigate small radio-opaque objects at a-few-microns high resolution, in a nondestructive, non-invasive, and tri-dimensional way. Compared to traditional optical and electron microscopy techniques, which provide two-dimensional images, this innovative investigation technology enables a sample tri-dimensional analysis without cutting, coating or exposing the object to any particular chemical treatment. X-ray micro-tomography matches ideal 3D microscopy features: the possibility of investigating an object in natural conditions and without any preparation or alteration; non-invasive, non-destructive, and sufficiently magnified 3D reconstruction; reliable measurement of numeric data of the internal structure (morphology, structure and ultra-structure. Hence, this technique has multi-fold applications in a wide range of fields, not only in medical and odontostomatologic areas, but also in biomedical engineering, materials science, biology, electronics, geology, archaeology, oil industry, and semi-conductors industry. This study shows possible applications of micro-CT in dental implantology to analyze 3D micro-features of dental implant to abutment interface. Indeed, implant-abutment misfit is known to increase mechanical stress on connection structures and surrounding bone tissue. This condition may cause not only screw preload loss or screw fracture, but also biological issues in peri-implant tissues.

  4. Helium-flow measurement using ultrasonic technique

    International Nuclear Information System (INIS)

    Sondericker, J.H.

    1983-01-01

    While designing cryogenic instrumentation for the Colliding Beam Accelerator (CBA) helium-distribution system it became clear that accurate measurement of mass flow of helium which varied in temperature from room to sub-cooled conditions would be difficult. Conventional venturi flow meters full scale differential pressure signal would decrease by more than an order of magnitude during cooldown causing unacceptable error at operating temperature. At sub-cooled temperatures, helium would be pumped around cooling loops by an efficient, low head pressure circulating compressor. Additional pressure drop meant more pump work was necessary to compress the fluid resulting in a higher outlet temperature. The ideal mass flowmeter for this application was one which did not add pressure drop to the system, functioned over the entire temperature range, has high resolution and delivers accurate mass flow measurement data. Ultrasonic flow measurement techniques used successfully by the process industry, seemed to meet all the necessary requirements. An extensive search for a supplier of such a device found that none of the commercial stock flowmeters were adaptable to cryogenic service so the development of the instrument was undertaken by the CBA Cryogenic Control and Instrumentation Engineering Group at BNL

  5. Leaf proteome analysis of clematis chinensis: a traditional chinese medicine (tcm) by two-dimensional electrophoresis technique

    International Nuclear Information System (INIS)

    Ishtiaq, M.; Maqbool, M.; Hussaini, T.; Azami, S.

    2014-01-01

    Leaf proteome of Clematis chinensis, a traditional Chinese medicine (TCM) was analyzed by two-dimensional electrophoresis (2-DE) technique. The samples were extracted by phenol-SDS method (PSM) with high protein quantity i.e. 2.35, 0.345 mg/g (yield/dw). Proteins were visualized by staining of gels by silver stain and CBB. The gel images of each species were compared by Image Master 2D Platinum software for analytical purpose. The 2-DE profile depicted distribution of 1085 spots and out of these only 255 protein spots (23.5%) were common to all analyzed taxa. The visualized protein spots showed pI range from 3.0 to 10.0 (pH) and Mr of 7 kDa to 70 kDa. Twelve proteins were exclusively specific to C. chinensis when compared with its allies, C. finetiana and C. armandii, which may be used as biomarkers. Thirteen proteins were up-regulated in C. finetiana (0.75-0.95 fold) and twelve proteins in C. armandii (1.05-1.66 fold) whilst seven proteins down-regulated (0.66-0.94 fold) in former and three proteins (1.07-1.20 fold) in later one in comparison with C. chinensis. Twenty five differential and similar protein spots were picked and analyzed by LC-MS/MS technique. Identified proteins are related to energy metabolism (ATP synthesis), photosynthesis. environmental stimuli, regulating RNA metabolism, growth hormone regulators, evolutionary trends and gene expression. The efficiency and applicability of proteomic approach as biomarker for identification of C. chinensis is discussed in its quality control (QC) perspectives. Leaf proteins of Clematis plants are explored for the first time by 2-DE technique and debated for their metabolic role. (author)

  6. The Role of Green and Traditional Supplier Attributes on Business Performance

    Directory of Open Access Journals (Sweden)

    José Roberto Mendoza-Fong

    2017-08-01

    Full Text Available Supplier evaluation and selection are fundamental tasks since they are part of the production process and even initiate the supply chain (SC. Despite their importance in the production system, supplier evaluation and selection may be challenging activities to be performed if companies look at the wide range of available evaluation techniques and methodologies, which now seek to integrate both traditional and green attributes. In addition, companies may refuse to take into account green attributes during the supplier selection process, because they do not know their impact on commercial benefits. To overcome this limitation, this study examines the Mexican manufacturing sector and measures the impact of supplier traditional attributes and green attributes on business performance, namely production process benefits and commercial benefits. As data collection instrument, we administered a survey to 253 supplier evaluators and selectors; then, using the gathered data, we constructed a structural equation model. The model includes four variables to determine the impact of traditional and green attributes on business performance: green attributes, traditional attributes, production process benefits, and commercial benefits. The results indicate that all the latent variables have positive direct effects on one another. For instance, process benefits show the largest effects on commercial benefits, but the most significant effect is caused by traditional attributes on commercial benefits through green attributes and production process benefits.

  7. Fluvial sediment transport: Analytical techniques for measuring sediment load

    International Nuclear Information System (INIS)

    2005-07-01

    Sediment transport data are often used for the evaluation of land surface erosion, reservoir sedimentation, ecological habitat quality and coastal sediment budgets. Sediment transport by rivers is usually considered to occur in two major ways: (1) in the flow as a suspended load and (2) along the bed as a bed load. This publication provides guidance on selected techniques for the measurement of particles moving in both modes in the fluvial environment. The relative importance of the transport mode is variable and depends on the hydraulic and sedimentary conditions. The potential user is directed in the selection of an appropriate technique through the presentation of operating principles, application guidelines and estimated costs. Techniques which require laboratory analysis are grab sample, pump sample, depth sample, point integrated and radioactive tracers. Techniques which will continuously record data are optical backscattering, nuclear transmission, single frequency acoustic and laser diffraction

  8. A photoacoustic technique to measure the properties of single cells

    Science.gov (United States)

    Strohm, Eric M.; Berndl, Elizabeth S. L.; Kolios, Michael C.

    2013-03-01

    We demonstrate a new technique to non-invasively determine the diameter and sound speed of single cells using a combined ultrasonic and photoacoustic technique. Two cell lines, B16-F1 melanoma cells and MCF7 breast cancer cells were examined using this technique. Using a 200 MHz transducer, the ultrasound backscatter from a single cell in suspension was recorded. Immediately following, the cell was irradiated with a 532 nm laser and the resulting photoacoustic wave recorded by the same transducer. The melanoma cells contain optically absorbing melanin particles, which facilitated photoacoustic wave generation. MCF7 cells have negligible optical absorption at 532 nm; the cells were permeabilized and stained with trypan blue prior to measurements. The measured ultrasound and photoacoustic power spectra were compared to theoretical equations with the cell diameter and sound speed as variables (Anderson scattering model for ultrasound, and a thermoelastic expansion model for photoacoustics). The diameter and sound speed were extracted from the models where the spectral shape matched the measured signals. However the photoacoustic spectrum for the melanoma cell did not match theory, which is likely because melanin particles are located around the cytoplasm, and not within the nucleus. Therefore a photoacoustic finite element model of a cell was developed where the central region was not used to generate a photoacoustic wave. The resulting power spectrum was in better agreement with the measured signal than the thermoelastic expansion model. The MCF7 cell diameter obtained using the spectral matching method was 17.5 μm, similar to the optical measurement of 16 μm, while the melanoma cell diameter obtained was 22 μm, similar to the optical measurement of 21 μm. The sound speed measured from the MCF7 and melanoma cell was 1573 and 1560 m/s, respectively, which is within acceptable values that have been published in literature.

  9. Calibration technique for the neutron surface moisture measurement system

    International Nuclear Information System (INIS)

    Watson, W.T.; Shreve, D.C.

    1996-01-01

    A technique for calibrating the response of a surface neutron moisture measurement probe to material moisture concentration has been devised. Tests to ensure that the probe will function in the expected in-tank operating environment are also outlined

  10. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    International Nuclear Information System (INIS)

    Prasser, H.M.

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  11. An improved arterial pulsation measurement system based on optical triangulation and its application in the traditional Chinese medicine

    Science.gov (United States)

    Wu, Jih-Huah; Lee, Wen-Li; Lee, Yun-Parn; Lin, Ching-Huang; Chiou, Ji-Yi; Tai, Chuan-Fu; Jiang, Joe-Air

    2011-08-01

    An improved arterial pulsation measurement (APM) system that uses three LED light sources and a CCD image sensor to measure pulse waveforms of artery is presented. The relative variations of the pulses at three measurement points near wrist joints can be determined by the APM system simultaneously. The height of the arterial pulsations measured by the APM system achieves a resolution of better than 2 μm. These pulsations contain useful information that can be used as diagnostic references in the traditional Chinese medicine (TCM) in the future.

  12. Analysis of Traditional Historical Clothing

    DEFF Research Database (Denmark)

    Jensen, Karsten; Schmidt, A. L.; Petersen, A. H.

    2013-01-01

    for establishing a three-dimensional model and the corresponding two-dimensional pattern for items of skin clothing that are not flat. The new method is non-destructive, and also accurate and fast. Furthermore, this paper presents an overview of the more traditional methods of pattern documentation and measurement......A recurrent problem for scholars who investigate traditional and historical clothing is the measuring of items of clothing and subsequent pattern construction. The challenge is to produce exact data without damaging the item. The main focus of this paper is to present a new procedure...

  13. 3D shape measurement of automotive glass by using a fringe reflection technique

    Science.gov (United States)

    Skydan, O. A.; Lalor, M. J.; Burton, D. R.

    2007-01-01

    In automotive and glass making industries, there is a need for accurately measuring the 3D shapes of reflective surfaces to speed up and ensure product development and manufacturing quality by using non-contact techniques. This paper describes a technique for the measurement of non-full-field reflective surfaces of automotive glass by using a fringe reflection technique. Physical properties of the measurement surfaces do not allow us to apply optical geometries used in existing techniques for surface measurement based upon direct fringe pattern illumination. However, this property of surface reflectivity can be used to implement similar ideas from existing techniques in a new improved method. In other words, the reflective surface can be used as a mirror to reflect illuminated fringe patterns onto a screen behind. It has been found that in the case of implementing the reflective fringe technique, the phase-shift distribution depends not only on the height of the object but also on the slope at each measurement point. This requires the solving of differential equations to find the surface slope and height distributions in the x and y directions and development of the additional height reconstruction algorithms. The main focus has been made on developing a mathematical model of the optical sub-system and discussing ways for its practical implementation including calibration procedures. A number of implemented image processing algorithms for system calibration and data analysis are discussed and two experimental results are given for automotive glass surfaces with different shapes and defects. The proposed technique showed the ability to provide accurate non-destructive measurement of 3D shapes of the reflective automotive glass surfaces and can be used as a key element for a glass shape quality control system on-line or in a laboratory environment.

  14. Written mathematical traditions in Ancient Mesopotamia

    DEFF Research Database (Denmark)

    Høyrup, Jens

    2015-01-01

    Writing, as well as various mathematical techniques, were created in proto-literate Uruk in order to serve accounting, and Mesopotamian mathematics as we know it was always expressed in writing. In so far, mathematics generically regarded was always part of the generic written tradition....

  15. Description of measurement techniques for surface contaminations

    International Nuclear Information System (INIS)

    Bourrez, E.

    2001-01-01

    The needs of evaluation of the surface contamination are numerous in the processes of production and management of radioactive waste. The market of radiation protection materials proposes a lot of devices answering to the almost all these needs. These device have however their conditions and particular limits for use. To realize correct measurements it is use the device, the technique and the methods adapted to the need, by taking into account the optimization of economical aspect. (N.C.)

  16. Discharge measurements at gaging stations

    Science.gov (United States)

    Turnipseed, D. Phil; Sauer, Vernon B.

    2010-01-01

    The techniques and standards for making discharge measurements at streamflow gaging stations are described in this publication. The vertical axis rotating-element current meter, principally the Price current meter, has been traditionally used for most measurements of discharge; however, advancements in acoustic technology have led to important developments in the use of acoustic Doppler current profilers, acoustic Doppler velocimeters, and other emerging technologies for the measurement of discharge. These new instruments, based on acoustic Doppler theory, have the advantage of no moving parts, and in the case of the acoustic Doppler current profiler, quickly and easily provide three-dimensional stream-velocity profile data through much of the vertical water column. For much of the discussion of acoustic Doppler current profiler moving-boat methodology, the reader is referred to U.S. Geological Survey Techniques and Methods 3-A22 (Mueller and Wagner, 2009). Personal digital assistants (PDAs), electronic field notebooks, and other personal computers provide fast and efficient data-collection methods that are more error-free than traditional hand methods. The use of portable weirs and flumes, floats, volumetric tanks, indirect methods, and tracers in measuring discharge are briefly described.

  17. A New Technique for Deep in situ Measurements of the Soil Water Retention Behaviour

    DEFF Research Database (Denmark)

    Rocchi, Irene; Gragnano, Carmine Gerardo; Govoni, Laura

    2018-01-01

    to monitor shallow landslides and seasonal volume changes beneath shallow foundations, within the most superficial ground strata. In this paper, a novel installation technique is presented, discussed and assessed, which allows to extend the use of commercially available low cost and low maintenance...... to the field data. The results of this study offer a convenient starting point to accommodate important geotechnical works such as river and road embankments in the traditional monitoring of unsaturated soil variables....

  18. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  19. Ambient versus traditional environment in pediatric emergency department.

    Science.gov (United States)

    Robinson, Patricia S; Green, Jeanette

    2015-01-01

    We sought to examine the effect of exposure to an ambient environment in a pediatric emergency department. We hypothesized that passive distraction from ambient lighting in an emergency department would lead to reduction in patient pain and anxiety and increased caregiver satisfaction with services. Passive distraction has been associated with lower anxiety and pain in patients and affects perception of wait time. A pediatric ED was designed that optimized passive distraction techniques using colorful ambient lighting. Participants were nonrandomly assigned to either an ambient ED environment or a traditional ED environment. Entry and exit questionnaires assessed caregiver expectations and experiences. Pain ratings were obtained with age-appropriate scales, and wait times were recorded. A total of 70 participants were assessed across conditions, that is, 40 in the ambient ED group and 30 in the traditional ED group. Caregivers in the traditional ED group expected a longer wait, had higher anxiety pretreatment, and felt more scared than those in the ambient ED group. Caregivers in the ambient ED group felt more included in the care of their child and rated quality of care higher than caregivers in the traditional ED group. Pain ratings and administrations of pain medication were lower in the ambient ED group. Mean scores for the ambient ED group were in the expected direction on several items measuring satisfaction with ED experiences. Results were suggestive of less stress in caregivers, less pain in patients, and higher satisfaction levels in the ambient ED group. © The Author(s) 2015.

  20. Computer Aided Measurement Laser (CAML): technique to quantify post-mastectomy lymphoedema

    International Nuclear Information System (INIS)

    Trombetta, Chiara; Abundo, Paolo; Felici, Antonella; Ljoka, Concetta; Foti, Calogero; Cori, Sandro Di; Rosato, Nicola

    2012-01-01

    Lymphoedema can be a side effect of cancer treatment. Eventhough several methods for assessing lymphoedema are used in clinical practice, an objective quantification of lymphoedema has been problematic. The aim of the study was to determine the objectivity, reliability and repeatability of the computer aided measurement laser (CAML) technique. CAML technique is based on computer aided design (CAD) methods and requires an infrared laser scanner. Measurements are scanned and the information describing size and shape of the limb allows to design the model by using the CAD software. The objectivity and repeatability was established in the beginning using a phantom. Consequently a group of subjects presenting post-breast cancer lymphoedema was evaluated using as a control the contralateral limb. Results confirmed that in clinical settings CAML technique is easy to perform, rapid and provides meaningful data for assessing lymphoedema. Future research will include a comparison of upper limb CAML technique between healthy subjects and patients with known lymphoedema.

  1. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Comparing and assessing different measurement techniques for mercury in coal systhesis gas

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, D.P.; Richardson, C.F. [Radian Corporation, Austin, TX (United States)

    1995-11-01

    Three mercury measurement techniques were performed on synthesis gas streams before and after an amine-based sulfur removal system. The syngas was sampled using (1) gas impingers containing a nitric acid-hydrogen peroxide solution, (2) coconut-based charcoal sorbent, and (3) an on-line atomic absorption spectrophotometer equipped with a gold amalgamation trap and cold vapor cell. Various impinger solutions were applied upstream of the gold amalgamation trap to remove hydrogen sulfide and isolate oxidized and elemental species of mercury. The results from these three techniques are compared to provide an assessment of these measurement techniques in reducing gas atmospheres.

  3. Comparing Physical Examination With Sonographic Versions of the Same Examination Techniques for Splenomegaly.

    Science.gov (United States)

    Cessford, Tara; Meneilly, Graydon S; Arishenkoff, Shane; Eddy, Christopher; Chen, Luke Y C; Kim, Daniel J; Ma, Irene W Y

    2017-12-08

    To determine whether sonographic versions of physical examination techniques can accurately identify splenomegaly, Castell's method (Ann Intern Med 1967; 67:1265-1267), the sonographic Castell's method, spleen tip palpation, and the sonographic spleen tip technique were compared with reference measurements. Two clinicians trained in bedside sonography patients recruited from an urban hematology clinic. Each patient was examined for splenomegaly using conventional percussion and palpation techniques (Castell's method and spleen tip palpation, respectively), as well as the sonographic versions of these maneuvers (sonographic Castell's method and sonographic spleen tip technique). Results were compared with a reference standard based on professional sonographer measurements. The sonographic Castell's method had greater sensitivity (91.7% [95% confidence interval, 61.5% to 99.8%]) than the traditional Castell's method (83.3% [95% confidence interval, 51.6% to 97.9%]) but took longer to perform [mean ± SD, 28.8 ± 18.6 versus 18.8 ± 8.1 seconds; P = .01). Palpable and positive sonographic spleen tip results were both 100% specific, but the sonographic spleen tip method was more sensitive (58.3% [95% confidence interval, 27.7% to 84.8%] versus 33.3% [95% confidence interval, 9.9% to 65.1%]). Sonographic versions of traditional physical examination maneuvers have greater diagnostic accuracy than the physical examination maneuvers from which they are derived but may take longer to perform. We recommend a combination of traditional physical examination and sonographic techniques when evaluating for splenomegaly at the bedside. © 2017 by the American Institute of Ultrasound in Medicine.

  4. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  5. Development of Uncertainty Quantification Method for MIR-PIV Measurement using BOS Technique

    International Nuclear Information System (INIS)

    Seong, Jee Hyun; Song, Min Seop; Kim, Eung Soo

    2014-01-01

    Matching Index of Refraction (MIR) is frequently used for obtaining high quality PIV measurement data. ven small distortion by unmatched refraction index of test section can result in uncertainty problems. In this context, it is desirable to construct new concept for checking errors of MIR and following uncertainty of PIV measurement. This paper proposes a couple of experimental concept and relative results. This study developed an MIR uncertainty quantification method for PIV measurement using SBOS technique. From the reference data of the BOS, the reliable SBOS experiment procedure was constructed. Then with the combination of SBOS technique with MIR-PIV technique, velocity vector and refraction displacement vector field was measured simultaneously. MIR errors are calculated through mathematical equation, in which PIV and SBOS data are put. These errors are also verified by another BOS experiment. Finally, with the applying of calculated MIR-PIV uncertainty, correct velocity vector field can be obtained regardless of MIR errors

  6. Endoscopic Radiofrequency Ablation-Assisted Resection of Juvenile Nasopharyngeal Angiofibroma: Comparison with Traditional Endoscopic Technique.

    Science.gov (United States)

    McLaughlin, Eamon J; Cunningham, Michael J; Kazahaya, Ken; Hsing, Julianna; Kawai, Kosuke; Adil, Eelam A

    2016-06-01

    To evaluate the feasibility of radiofrequency surgical instrumentation for endoscopic resection of juvenile nasopharyngeal angiofibroma (JNA) and to test the hypothesis that endoscopic radiofrequency ablation-assisted (RFA) resection will have superior intraoperative and/or postoperative outcomes as compared with traditional endoscopic (TE) resection techniques. Case series with chart review. Two tertiary care pediatric hospitals. Twenty-nine pediatric patients who underwent endoscopic transnasal resection of JNA from January 2000 to December 2014. Twenty-nine patients underwent RFA (n = 13) or TE (n = 16) JNA resection over the 15-year study period. Mean patient age was not statistically different between the 2 groups (P = .41); neither was their University of Pittsburgh Medical Center classification stage (P = .79). All patients underwent preoperative embolization. Mean operative times were not statistically different (P = .29). Mean intraoperative blood loss and the need for a transfusion were also not statistically different (P = .27 and .47, respectively). Length of hospital stay was not statistically different (P = .46). Recurrence rates did not differ between groups (P = .99) over a mean follow-up period of 2.3 years. There were no significant differences between RFA and TE resection in intraoperative or postoperative outcome parameters. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  7. Microbial composition of the Korean traditional food "kochujang" analyzed by a massive sequencing technique.

    Science.gov (United States)

    Nam, Young-Do; Park, So-lim; Lim, Seong-Il

    2012-04-01

    Kochujang is a traditional Korean fermented food that is made with red pepper, glutinous rice, salt, and soybean. Kochujang is fermented by naturally occurring microorganisms through which it obtains various health-promoting properties. In this study, the bacterial diversities of 9 local and 2 commercial brands of kochujang were analyzed with a barcoded pyrosequencing technique targeting the hyper-variable regions V1/V2 of the 16S rRNA gene. Through the analysis of 13524 bacterial pyrosequences, 223 bacterial species were identified, most of which converged on the phylum Firmicutes (average 93.1%). All of the kochujang samples were largely populated (>90.9% of abundance) by 12 bacterial families, and Bacillaceae showed the highest abundance in all but one sample. Bacillus subtilis and B. licheniformis were the most dominant bacterial species and were broadly distributed among the kochujang samples. Each sample contained a high abundance of region-specific bacterial species, such as B. sonorensis, B. pumilus, Weissella salipiscis, and diverse unidentified Bacillus species. Phylotype- and phylogeny-based community comparison analysis showed that the microbial communities of the two commercial brands were different from those of the local brands. Moreover, each local brand kochujang sample had region-specific microbial community reflecting the manufacturing environment. © 2012 Institute of Food Technologists®

  8. Documentation of tests on particle size methodologies for laser diffraction compared to traditional sieving and sedimentation analysis

    DEFF Research Database (Denmark)

    Rasmussen, Charlotte; Dalsgaard, Kristian

    Sieving and sedimentation analyses by pipette or hydrometer are historically the traditional methods for determining particle size distributions (PSD). A more informative and faster alternative has for years been laser diffraction (LD). From 2003 to 2013 the authors of this paper have worked...... intensively with PSD and performed various tests and investigations, using LD, sedimentation (by pipette) and sieving. The aim was to improve and understand the relationship between these various techniques, pre-treatment effects and preferably find a unifying correlation factor. As a result, method...... comparisons of LD and sieving/sedimentation are difficult, as LD is a 3D optical volume measurement, sieving is a 2D width measurement, and sedimentation is density dependent. Platy particles like clay are generally measured to be coarser than traditional methods when LD is used. For LD the clay...

  9. Natural stream flow-rates measurements by tracer techniques

    International Nuclear Information System (INIS)

    Cuellar Mansilla, J.

    1982-01-01

    This paper presents the study of the precision obtained measuring the natural stream flow rates by tracer techniques, especially when the system presents a great slope and a bed constituted by large and extended particle size. The experiences were realized in laboratory pilot channels with flow-rates between 15 and 130 [1/s]; and in natural streams with flow-rates from 1 to 25 m 3 /s. Tracer used were In-133m and Br-82 for laboratory and field measurements respectively. In both cases the tracer was injected as a pulse and its dilution measured collecting samples in the measured section, at constant flow-rates, of 5[1] in laboratory experiences and 60[1] of water in field experiences. Precisions obtained at a 95% confidence level were about 2% for laboratory and 3% for field. (I.V.)

  10. A confirmatory measurement technique for highly enriched uranium

    International Nuclear Information System (INIS)

    Sprinkle, J.K. Jr.

    1987-07-01

    This report describes a confirmatory measurement technique for measuring uranium items in their shipping containers. The measurement consists of a weight verification and the detection of three gamma rays. The weight can be determined very precisely, thus it severely constrains the options of the diverter who might want to imitate the gamma signal with a bogus item. The 185.7-keV gamma ray originates from 235 U, the 1001 keV originates from a daughter of 238 U, and the 2614 keV originates from a daughter of 232 U. These three gamma rays exhibit widely different attenuation properties, they correlate with enrichment and total uranium mass, and they rigorously discriminate against a likely diversion scenario (low-enriched uranium substitution). These four measured quantities, when combined, provide a signature that is very difficult to counterfeit

  11. Noble Gas Measurement and Analysis Technique for Monitoring Reprocessing Facilities

    International Nuclear Information System (INIS)

    William S. Charlton

    1999-01-01

    An environmental monitoring technique using analysis of stable noble gas isotopic ratios on-stack at a reprocessing facility was developed. This technique integrates existing technologies to strengthen safeguards at reprocessing facilities. The isotopic ratios are measured using a mass spectrometry system and are compared to a database of calculated isotopic ratios using a Bayesian data analysis method to determine specific fuel parameters (e.g., burnup, fuel type, fuel age, etc.). These inferred parameters can be used by investigators to verify operator declarations. A user-friendly software application (named NOVA) was developed for the application of this technique. NOVA included a Visual Basic user interface coupling a Bayesian data analysis procedure to a reactor physics database (calculated using the Monteburns 3.01 code system). The integrated system (mass spectrometry, reactor modeling, and data analysis) was validated using on-stack measurements during the reprocessing of target fuel from a U.S. production reactor and gas samples from the processing of EBR-II fast breeder reactor driver fuel. These measurements led to an inferred burnup that matched the declared burnup with sufficient accuracy and consistency for most safeguards applications. The NOVA code was also tested using numerous light water reactor measurements from the literature. NOVA was capable of accurately determining spent fuel type, burnup, and fuel age for these experimental results. Work should continue to demonstrate the robustness of this system for production, power, and research reactor fuels

  12. 4. Workshop - Measurement techniques of stationary and transient multiphase flow

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M. (ed.)

    2001-05-01

    In November 2000, the 4th Workshop on Measurement Techniques for Stationary and Transient Multiphase Flows took place in Rossendorf. Three previous workshops of this series were national meetings; this time participants from different countries took part. The programme comprised 14 oral presentations, 9 of which are included in these proceedings in full length. A special highlight of the meeting was the main lecture ''Ultrasonic doppler method for bubbly flow measurement'' of Professor Masanori Aritomi, Dr. Hiroshige Kikura and Dr. Yumiko Suzuki. The workshop again dealt with high-resolution phase distribution and phase velocity measurement techniques based on electrical conductivity, ultrasound, laser light and high-speed cinematography. A number of presentations were dedicated to the application of wire-mesh sensors developed by FZR for different applications used by the Technical Universities of Delft and Munich and the Tokyo Institute of Technology. (orig.)

  13. Comparing the Knotless Tension Band and the Traditional Stainless Steel Wire Tension Band Fixation for Medial Malleolus Fractures: A Retrospective Clinical Study

    Directory of Open Access Journals (Sweden)

    Michael W. Downey

    2016-01-01

    Full Text Available The traditional stainless steel wire tension band (WTB has been popularized for small avulsion fractures at the medial malleolus. Despite the tension band principle creating a stable construct, complications continue to arise utilizing the traditional stainless steel WTB with patients experiencing hardware irritation at the tension band site and subsequent hardware removal. Coupled with hardware irritation is fatigue failure with the wire. The goal of this investigation was to retrospectively compare this traditional wire technique to an innovative knotless tension band (KTB technique in order to decrease costly complications. A total of 107 patients were reviewed with a minimum follow-up of 1 year. Outcome measures include descriptive data, fracture classification, results through economic costs, and fixation results (including hardware status, healing status, pain status, and time to healing. The KTB group had a 13% lower true cost as compared to the WTB group while the fixation results were equivocal for the measured outcomes. Our results demonstrate that the innovative KTB is comparable to the traditional WTB while offering a lower true cost, an irritation free reduction all without the frustration of returning to the operating room for additional hardware removal, which averages approximately to $8,288.

  14. Effect of heterophoria measurement technique on the clinical accommodative convergence to accommodation ratio.

    Science.gov (United States)

    Escalante, Jaime Bernal; Rosenfield, Mark

    2006-05-01

    Measurement of the stimulus accommodative convergence to accommodation (AC/A) ratio is a standard procedure in clinical optometric practice. Typically, heterophoria is assessed at several accommodative stimulus levels, and the gradient of the vergence to accommodation function computed. A number of procedures are available for the subjective measurement of heterophoria, but it is unclear whether the use of different vergence measurement techniques will alter the obtained AC/A value. Accordingly, the current study compared AC/A ratios measured using 3 clinical subjective heterophoria tests, namely the von Graefe (VG), Maddox Rod (MR), and Modified Thorington (MT) procedures. The AC/A ratio was measured in 60 visually normal subjects between 20 and 25 years of age using each of the 3 procedures listed above. The accommodative stimulus was varied by the introduction of +/-1.00 diopter (D) spherical lenses over the distance refractive correction while subjects viewed a target at a viewing distance of 40 cm. To examine the repeatability of each procedure, the AC/A ratio was measured on 2 separate occasions for each measurement technique, with the 2 sessions being separated by at least 24 hours. Mean values of stimulus AC/A ratio measured using the VG, MR, and MT procedures were 3.47, 2.99, and 2.46Delta/D, respectively. These differences were significant (p=0.0001). In addition, the coefficient of repeatability for the 3 techniques was 2.22, 1.99, and 1.20 Delta/D, respectively. Ratios obtained using the Modified Thorington technique with +/-1.00 D lenses showed the best repeatability, whereas the poorest repeatability was found with the von Graefe technique when only +1.00 D lenses were used to vary the accommodative stimulus. Accordingly, we recommend that that Modified Thorington procedure with +/-1.00 D lenses be used to quantify heterophoria during clinical measurement of the stimulus AC/A ratio.

  15. Uncertainty Analysis for Oil-Film Interferometry Skin-Friction Measurement Techniques

    Science.gov (United States)

    Naughton, Jonathan W.; Brown, James L.; Merriam, Marshal (Technical Monitor)

    1996-01-01

    Over the past 20 years, the use of oil-film interferometry to measure the skin friction coefficient (C(sub f) = tau/q where tau is the surface shear stress and q is the dynamic pressure) has increased. Different forms of this oil-film technique with various levels of accuracy and ease of use have been successfully applied in a wide range of flows. The method's popularity is growing due to its relative ease of implementation and minimal intrusiveness as well as an increased demand for C(sub f) measurements. Nonetheless, the accuracy of these methods has not been rigorously addressed to date. Most researchers have simply shown that the skin-friction measurements made using these techniques compare favorably with other measurements and theory, most of which are only accurate to within 5-20%. The use of skin-friction data in the design of commercial aircraft, whose drag at cruise is 50% skin-friction drag, and in the validation of computational fluid dynamics programs warrants better uncertainty estimates. Additional information is contained in the original extended abstract.

  16. New techniques to measure cliff change from historical oblique aerial photographs and structure-from-motion photogrammetry

    Science.gov (United States)

    Warrick, Jonathan; Ritchie, Andy; Adelman, Gabrielle; Adelman, Ken; Limber, Patrick W.

    2017-01-01

    Oblique aerial photograph surveys are commonly used to document coastal landscapes. Here it is shown that adequate overlap may exist in these photographic records to develop topographic models with Structure-from-Motion (SfM) photogrammetric techniques. Using photographs of Fort Funston, California, from the California Coastal Records Project, imagery were combined with ground control points in a four-dimensional analysis that produced topographic point clouds of the study area’s cliffs for 5 years spanning 2002 to 2010. Uncertainty was assessed by comparing point clouds with airborne LIDAR data, and these uncertainties were related to the number and spatial distribution of ground control points used in the SfM analyses. With six or more ground control points, the root mean squared errors between the SfM and LIDAR data were less than 0.30 m (minimum 1⁄4 0.18 m), and the mean systematic error was less than 0.10 m. The SfM results had several benefits over traditional airborne LIDAR in that they included point coverage on vertical- to-overhanging sections of the cliff and resulted in 10–100 times greater point densities. Time series of the SfM results revealed topographic changes, including landslides, rock falls, and the erosion of landslide talus along the Fort Funston beach. Thus, it was concluded that SfM photogrammetric techniques with historical oblique photographs allow for the extraction of useful quantitative information for mapping coastal topography and measuring coastal change. The new techniques presented here are likely applicable to many photograph collections and problems in the earth sciences.

  17. Moisture measurements in iron ores, in freight cars, through nuclear techniques

    International Nuclear Information System (INIS)

    Castagnet, A.C.; Said, M.; Duarte, U.

    1975-01-01

    The possibility and the advantages of using a nuclear technique for measuring on the spot (in the freight cars) and the moisture content of iron ores are described. The measurements included the determination of the volumetric moisture content and the density. From this values, the moisture content in percentage by weight was calculated. Nuclear Chicago d/M Combination Density-Moisture Probe with a 5 mCi Ra/Be source, and a digital portable scaler, were used. The investigated techniques give good results when the measurements are made directly on the ore surface, and has economical advantages over the gravimetric method by sampling. The probable reasons for both, the aleatory scattering of points and the lack of linear correlation between the values of both methods, when the nuclear measurement is made across the car walls are analized

  18. Instrument for all-fiber structure measurement of ultra-low turbidity by using single photon detection technique

    Science.gov (United States)

    Qin, Feihu; Hu, Juntao; Wang, Huanqin; Gui, Huaqiao; Liu, Jianguo; Lü, Liang; Kong, Deyi; Zhang, Jian; Han, Xia; Wang, Tianli

    2017-10-01

    An all-fiber structure detection system based on single photon detection technique(SPDT) has been developed to measure the ultra-low turbidity ofliquids. To assure the measurement accuracy,the total intensity of transmission light has been detected and quantified as number of photons by avalanche photodiode (APD) which has the advantage of high sensitivity.A fresh all-fiber structure optical fiber probe based on SPDT is applied in the system to reduce the volume and fluctuation of traditional transmission-light measurement system,in which the all-fiber structure probe is used to delivery and collection of transmission light.On the basis of Beer-Lambert (B-L) transmission law,a test system has been established and carried out a series of experiments.By combining B-Llaw with the principle of SPDT,a novel model for detecting turbidity has been proposed to explain the experimental results.The results have shown a well exponential relationship over the range of 0.01-1NTU (Nephelometric Turbidity Units).It also has showna good linear relationship with a resolution as high as 0.01NTUin the range of 0.01-0.09 NTU.When it is 1 secondofthe sampling time,the mean error of measurement result can be controlled within 5% of full scale.In addition,the new detection structure proposed in this paper, which makes the system more compact and more suitable in the small special space.

  19. Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

    International Nuclear Information System (INIS)

    Martens, Hans-Juergen von

    2010-01-01

    The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s 2 ). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

  20. Pressure Measurement Techniques for Abdominal Hypertension: Conclusions from an Experimental Model.

    Science.gov (United States)

    Chopra, Sascha Santosh; Wolf, Stefan; Rohde, Veit; Freimann, Florian Baptist

    2015-01-01

    Introduction. Intra-abdominal pressure (IAP) measurement is an indispensable tool for the diagnosis of abdominal hypertension. Different techniques have been described in the literature and applied in the clinical setting. Methods. A porcine model was created to simulate an abdominal compartment syndrome ranging from baseline IAP to 30 mmHg. Three different measurement techniques were applied, comprising telemetric piezoresistive probes at two different sites (epigastric and pelvic) for direct pressure measurement and intragastric and intravesical probes for indirect measurement. Results. The mean difference between the invasive IAP measurements using telemetric pressure probes and the IVP measurements was -0.58 mmHg. The bias between the invasive IAP measurements and the IGP measurements was 3.8 mmHg. Compared to the realistic results of the intraperitoneal and intravesical measurements, the intragastric data showed a strong tendency towards decreased values. The hydrostatic character of the IAP was eliminated at high-pressure levels. Conclusion. We conclude that intragastric pressure measurement is potentially hazardous and might lead to inaccurately low intra-abdominal pressure values. This may result in missed diagnosis of elevated abdominal pressure or even ACS. The intravesical measurements showed the most accurate values during baseline pressure and both high-pressure plateaus.

  1. The verification tests of residual radioactivity measurement and assessment techniques for buildings and soils

    International Nuclear Information System (INIS)

    Onozawa, T.; Ishikura, T.; Yoshimura, Yukio; Nakazawa, M.; Makino, S.; Urayama, K.; Kawasaki, S.

    1996-01-01

    According to the standard procedure for decommissioning a commercial nuclear power plant (CNPP) in Japan, controlled areas will be released for unrestricted use before the dismantling of a reactor building. If manual survey and sampling techniques were applied to measurement for unrestricted release on and in the extensive surface of the building, much time and much specialized labor would be required to assess the appropriateness of the releasing. Therefore the authors selected the following three techniques for demonstrating reliability and applicability of the techniques for CNPPs: (1) technique of assessing radioactive concentration distribution on the surface of buildings (ADB); (2) technique of assessing radioactive permeation distribution in the concrete structure of buildings (APB); (3) technique of assessing radioactive concentration distribution in soil (ADS). These tests include the techniques of measuring and assessing very low radioactive concentration distribution on the extensive surfaces of buildings and the soil surrounding of a plant with automatic devices. Technical investigation and preliminary study of the verification tests were started in 1990. In the study, preconditions were clarified for each technique and the performance requirements were set up. Moreover, simulation models have been constructed for several feasible measurement method to assess their performance in terms of both measurement test and simulation analysis. Fundamental tests have been under way using small-scale apparatuses since 1994

  2. Nanostructured micro-electrode arrays for electrophysiological measurements

    DEFF Research Database (Denmark)

    Wierzbicki, Rafal Dominik

    Potential and electrochemical measurements of biological cell electroactivity is crucial in cell biology research. The traditional technique with a micrometer-sharp glass pipette equipped with a metal wire within its core or electrically conductive saline solution allows extracellular, ion...

  3. Measurement and characterization techniques for thermoelectric materials

    Energy Technology Data Exchange (ETDEWEB)

    Tritt, T M

    1997-07-01

    Characterization of thermoelectric materials can pose many problems. A temperature difference can be established across these materials as an electrical current is passed due to the Peltier effect. The thermopower of these materials is quite large and thus large thermal voltages can contribute to many of the measurements necessary to investigate these materials. This paper will discuss the chracterization techniques necessary to investigate these materials and provide an overview of some of the potential systematic errors which can arise. It will also discuss some of the corrections one needs to consider. This should provide an introduction to the characterization and measurement of thermoelectric materials and provide references for a more in depth discussion of the concepts. It should also serve as an indication of the care that must be taken while working with thermoelectric materials.

  4. Using the ultrasound and instrumented indentation techniques to measure the elastic modulus of engineering materials

    International Nuclear Information System (INIS)

    Meza, J. M.; Franco, E. E.; Farias, M. C. M.; Buiochi, F.; Souza, R. M.; Cruz, J.

    2008-01-01

    Currently, the acoustic and nano indentation techniques are two of the most used techniques for materials elastic modulus measurement. In this article fundamental principles and limitations of both techniques are shown and discussed. Last advances in nano indentation technique are also reviewed. an experimental study in ceramic, metallic, composite and single crystals was also done. Results shown that ultrasonic technique is capable to provide results in agreement with those reported in literature. However, ultrasonic technique does not allow measuring the elastic modulus of some small samples and single crystals. On the other hand, the nano indentation technique estimates the elastic modulus values in reasonable agreement with those measured by acoustic methods, particularly in amorphous materials, while in some policristaline materials some deviation from expected values was obtained. (Author) 29 refs

  5. Precision of lumbar intervertebral measurements: does a computer-assisted technique improve reliability?

    Science.gov (United States)

    Pearson, Adam M; Spratt, Kevin F; Genuario, James; McGough, William; Kosman, Katherine; Lurie, Jon; Sengupta, Dilip K

    2011-04-01

    Comparison of intra- and interobserver reliability of digitized manual and computer-assisted intervertebral motion measurements and classification of "instability." To determine if computer-assisted measurement of lumbar intervertebral motion on flexion-extension radiographs improves reliability compared with digitized manual measurements. Many studies have questioned the reliability of manual intervertebral measurements, although few have compared the reliability of computer-assisted and manual measurements on lumbar flexion-extension radiographs. Intervertebral rotation, anterior-posterior (AP) translation, and change in anterior and posterior disc height were measured with a digitized manual technique by three physicians and by three other observers using computer-assisted quantitative motion analysis (QMA) software. Each observer measured 30 sets of digital flexion-extension radiographs (L1-S1) twice. Shrout-Fleiss intraclass correlation coefficients for intra- and interobserver reliabilities were computed. The stability of each level was also classified (instability defined as >4 mm AP translation or 10° rotation), and the intra- and interobserver reliabilities of the two methods were compared using adjusted percent agreement (APA). Intraobserver reliability intraclass correlation coefficients were substantially higher for the QMA technique THAN the digitized manual technique across all measurements: rotation 0.997 versus 0.870, AP translation 0.959 versus 0.557, change in anterior disc height 0.962 versus 0.770, and change in posterior disc height 0.951 versus 0.283. The same pattern was observed for interobserver reliability (rotation 0.962 vs. 0.693, AP translation 0.862 vs. 0.151, change in anterior disc height 0.862 vs. 0.373, and change in posterior disc height 0.730 vs. 0.300). The QMA technique was also more reliable for the classification of "instability." Intraobserver APAs ranged from 87 to 97% for QMA versus 60% to 73% for digitized manual

  6. Higher order Cambell techniques for neutron flux measurement. Pt. 1

    International Nuclear Information System (INIS)

    Lux, I.; Baranyai, A.

    1982-01-01

    An exact mathematical description of arbitrary high order Campbell techniques for measuring particle fluxes is given. The nth order Campbell technique assumes the measurement of the moments of the outcoming voltage up to the nth one. A simple relation is derived among the various moments of the total measured voltage and of the detector signal caused by one incident particle. It is proven that in the monoparticle case combination of the measured moments up to the order n provides an expression proportional to the particle flux and to the nth moment of the detector signal. Generalization to several different particles is given and it is shown that if the flux of the particle causing the largest detector signal is measured with a relative error epsilon in the dc method and the error is due to the signals of other particles, then in the nth order campbelling the error will be of order epsilonsup(n). The effect of a random background on the measured voltage is also investigated and it is established that the nth order campbelling supresses the noise according to the nth power of the relative amplitude of the noise to the signal. The results concerning constant fluxes are generalized to time dependent particle fluxes and a method assuming a Fourier transform of the measured quantities is proposed for their determination. (orig.)

  7. Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

    International Nuclear Information System (INIS)

    Ravelo Arias, S. I.; Ramírez Muñoz, D.; Cardoso, S.; Ferreira, R.; Freitas, P.

    2015-01-01

    The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others

  8. Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ravelo Arias, S. I.; Ramírez Muñoz, D. [Department of Electronic Engineering, University of Valencia, Avda. de la Universitat, s/n, 46100-Burjassot (Spain); Cardoso, S. [INESC Microsystems and Nanotechnologies (INESC-MN) and Institute for Nanosciences and Nanotechnologies, R. Alves Redol 9, Lisbon 1000-029 (Portugal); Ferreira, R. [INL-International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, Braga 4715-31 (Portugal); Freitas, P. [INESC Microsystems and Nanotechnologies (INESC-MN) and Institute for Nanosciences and Nanotechnologies, R. Alves Redol 9, Lisbon 1000-029 (Portugal); INL-International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, Braga 4715-31 (Portugal)

    2015-06-15

    The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others.

  9. Micro/Nano-scale Strain Distribution Measurement from Sampling Moiré Fringes.

    Science.gov (United States)

    Wang, Qinghua; Ri, Shien; Tsuda, Hiroshi

    2017-05-23

    This work describes the measurement procedure and principles of a sampling moiré technique for full-field micro/nano-scale deformation measurements. The developed technique can be performed in two ways: using the reconstructed multiplication moiré method or the spatial phase-shifting sampling moiré method. When the specimen grid pitch is around 2 pixels, 2-pixel sampling moiré fringes are generated to reconstruct a multiplication moiré pattern for a deformation measurement. Both the displacement and strain sensitivities are twice as high as in the traditional scanning moiré method in the same wide field of view. When the specimen grid pitch is around or greater than 3 pixels, multi-pixel sampling moiré fringes are generated, and a spatial phase-shifting technique is combined for a full-field deformation measurement. The strain measurement accuracy is significantly improved, and automatic batch measurement is easily achievable. Both methods can measure the two-dimensional (2D) strain distributions from a single-shot grid image without rotating the specimen or scanning lines, as in traditional moiré techniques. As examples, the 2D displacement and strain distributions, including the shear strains of two carbon fiber-reinforced plastic specimens, were measured in three-point bending tests. The proposed technique is expected to play an important role in the non-destructive quantitative evaluations of mechanical properties, crack occurrences, and residual stresses of a variety of materials.

  10. Advanced intensity-modulation continuous-wave lidar techniques for ASCENDS CO2 column measurements

    Science.gov (United States)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. W.; Obland, Michael D.; Meadows, Byron

    2015-10-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  11. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for ASCENDS O2 Column Measurements

    Science.gov (United States)

    Campbell, Joel F.; Lin, Bing; Nehrir, Amin R.; Harrison, F. Wallace; Obland, Michael D.; Meadows, Byron

    2015-01-01

    Global atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity- Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space to meet the ASCENDS measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud contamination. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating the need to correct for sidelobe bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. A comparison of BPSK and linear swept-frequency is also discussed in this paper. These results are extended to include Richardson-Lucy deconvolution techniques to extend the resolution of the lidar beyond that implied by limit of the bandwidth of the modulation, where it is shown useful for making tree canopy measurements.

  12. Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    England, Andrew; Niker, Amanda; Redmond, Claire

    2010-01-01

    Purpose: The aim of this project is to assess the variability of six CT measurement techniques for sizing abdominal aortic aneurysms (AAAs). Method: 37 CT scans with known AAAs were loaded on to a departmental picture archiving and communication system (PACS). A team of three observers, with experience in aortic CT measurements and the PACS performed a series of 2D and 3D measurements on the abdominal aorta. Each observer was asked to measure 3 quantities; anterior-posterior AAA diameter, maximum oblique AAA diameter, maximum aneurysm area using both 2D and 3D techniques. In order to test intra-observer variability each observer was asked to repeat their measurements. All measurements were taken using electronic callipers, under standardised viewing conditions using previously calibrated equipment. 3D measurements were conducted using a computer generated central luminal line (CLL). All measurements for this group were taken perpendicular to the CLL. Results: A total of 972 independent measurements were recorded by three observers. Mean intra-observer variability was lower for 2D diameter measurements (AP 1.3 ± 1.6 mm; 2D Oblique 1.2 ± 1.3 mm) and 2D areas (0.7 ± 1.3 cm 2 ) when compared to inter-observer variability (AP 1.7 ± 1.9 mm; Oblique 1.6 ± 1.7 mm; area 1.1 ± 1.5 cm 2 ). When comparing 2D with 3D measurements, differences were comparable except for 3D AP diameter and area which had lower inter-observer variability than their 2D counterparts (AP 2D 1.7 ± 1.9 mm, 3D 1.3 ± 1.3 mm; area 2D 1.1 ± 1.5 cm 2 , 3D 0.7 ± 0.7 cm 2 ). 3D area measurement was the only technique which had equal variability for intra- and inter-observer measurements. Overall observer variability for the study was good with 94-100% of all paired measurements within 5.00 mm/cm 2 or less. Using Pitman's test it can be confirmed that area measurements in the 3D plane have the least variability (r = 0.031) and 3D oblique measurements have the highest variability (r = 0

  13. Technique for the focal-length measurement of positive lenses using Fizeau interferometry

    International Nuclear Information System (INIS)

    Pavan Kumar, Yeddanapudi; Chatterjee, Sanjib

    2009-01-01

    We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of ±2.5% is presented

  14. Simulation error propagation for a dynamic rod worth measurement technique

    International Nuclear Information System (INIS)

    Kastanya, D.F.; Turinsky, P.J.

    1996-01-01

    KRSKO nuclear station, subsequently adapted by Westinghouse, introduced the dynamic rod worth measurement (DRWM) technique for measuring pressurized water reactor rod worths. This technique has the potential for reduced test time and primary loop waste water versus alternatives. The measurement is performed starting from a slightly supercritical state with all rods out (ARO), driving a bank in at the maximum stepping rate, and recording the ex-core detectors responses and bank position as a function of time. The static bank worth is obtained by (1) using the ex-core detectors' responses to obtain the core average flux (2) using the core average flux in the inverse point-kinetics equations to obtain the dynamic bank worth (3) converting the dynamic bank worth to the static bank worth. In this data interpretation process, various calculated quantities obtained from a core simulator are utilized. This paper presents an analysis of the sensitivity to the impact of core simulator errors on the deduced static bank worth

  15. Test plan for suitability assessment of five overcoring stress measurement techniques

    International Nuclear Information System (INIS)

    Gregory, E.C.; Rundle, T.A.; McCabe, W.M.; Kim, K.

    1982-08-01

    Tests are to be conducted at the Near-Surface Test Facility (NSTF) to assess the suitability of five overcoring techniques for in situ stress determination in a jointed basalt. The overcoring methods to be investigated use the following instrumentation to measure strain relief by overcoring a pilot borehole: USBM borehole deformation gage, CSIRO hollow inclusion stress cell, cast epoxy inclusion, the Lulea triaxial strain cell and the ''doorstopper'' biaxial strain cell. The tests are to provide data regarding the state of stress below the NSTF. This information is to be used in the evaluation of each method of overcoring. During the course of field testing, an attempt is to be made to adapt conventional overcoring techniques and analytical methods to the basalt medium. If overcoring stress determination in basalt is shown suitable, then additional studies will be identified to further adapt a technique for use at depth. In addition to the five overcoring techniques to be tested at the NSTF, stress measurements by Hydrofracturing are to be conducted to provide data for direct comparison with overcoring results. 16 refs., 18 figs

  16. Reactivity change measurements on plutonium-uranium fuel elements in hector experimental techniques and results

    International Nuclear Information System (INIS)

    Tattersall, R.B.; Small, V.G.; MacBean, I.J.; Howe, W.D.

    1964-08-01

    The techniques used in making reactivity change measurements on HECTOR are described and discussed. Pile period measurements were used in the majority of oases, though the pile oscillator technique was used occasionally. These two methods are compared. Flux determinations were made in the vicinity of the fuel element samples using manganese foils, and the techniques used are described and an error assessment made. Results of both reactivity change and flux measurements on 1.2 in. diameter uranium and plutonium-uranium alloy fuel elements are presented, these measurements being carried out in a variety of graphite moderated lattices at temperatures up to 450 deg. C. (author)

  17. Top-quark mass measurements: Alternative techniques (LHC + Tevatron)

    CERN Document Server

    Adomeit, Stefanie; The ATLAS collaboration

    2014-01-01

    Measurements of the top-quark mass employing alternative techniques are presented, performed by the D0 and CDF collaborations at the Tevatron as well as the ATLAS and CMS experiments at the LHC. The alternative methods presented include measurements using the lifetime of $B$-hadrons, the transverse momentum of charged leptons and the endpoints of kinematic distributions in top quark anti-quark pair ($t\\bar{t}$) final states. The extraction of the top-quark pole mass from the $t\\bar{t}$ production cross-section and the normalized differential $t\\bar{t}$ + 1-jet cross-section are discussed as well as the top-quark mass extraction using fixed-order QCD predictions at detector level. Finally, a measurement of the top-quark mass using events enhanced in single top t-channel production is presented.

  18. Comparisons between different techniques for measuring mass segregation

    Science.gov (United States)

    Parker, Richard J.; Goodwin, Simon P.

    2015-06-01

    We examine the performance of four different methods which are used to measure mass segregation in star-forming regions: the radial variation of the mass function {M}_MF; the minimum spanning tree-based ΛMSR method; the local surface density ΣLDR method; and the ΩGSR technique, which isolates groups of stars and determines whether the most massive star in each group is more centrally concentrated than the average star. All four methods have been proposed in the literature as techniques for quantifying mass segregation, yet they routinely produce contradictory results as they do not all measure the same thing. We apply each method to synthetic star-forming regions to determine when and why they have shortcomings. When a star-forming region is smooth and centrally concentrated, all four methods correctly identify mass segregation when it is present. However, if the region is spatially substructured, the ΩGSR method fails because it arbitrarily defines groups in the hierarchical distribution, and usually discards positional information for many of the most massive stars in the region. We also show that the ΛMSR and ΣLDR methods can sometimes produce apparently contradictory results, because they use different definitions of mass segregation. We conclude that only ΛMSR measures mass segregation in the classical sense (without the need for defining the centre of the region), although ΣLDR does place limits on the amount of previous dynamical evolution in a star-forming region.

  19. Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 Measurements

    Science.gov (United States)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Liu, Z.; Kooi, S. A.; Fan, T. F.; Nehrir, A. R.; Meadows, B.; Browell, E. V.

    2016-12-01

    Advanced Intensity-Modulation Continuous-Wave Lidar Techniques for Column CO2 MeasurementsJoel F. Campbell1, Bing Lin1, Michael D. Obland1, Zhaoyan Liu1, Susan Kooi2, Tai-Fang Fan2, Amin R. Nehrir1, Byron Meadows1, Edward V. Browell31NASA Langley Research Center, Hampton, VA 23681 2SSAI, NASA Langley Research Center, Hampton, VA 23681 3STARSS-II Affiliate, NASA Langley Research Center, Hampton, VA 23681 AbstractGlobal and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) modulation technique to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby minimizing bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new sub-meter hyperfine interpolation techniques that takes advantage of the periodicity of the modulation waveforms. The BPSK technique under investigation has excellent auto-correlation properties while possessing a finite bandwidth. These techniques are used in a new data processing

  20. Work of adhesion measurements by a periodic cracking technique

    International Nuclear Information System (INIS)

    Davutoglu, A.; Aksay, I.A.

    1981-01-01

    In a recent study, Chow et al. introduced a technique for determining the energy associated with interfacial separation of a two-layer composite which consisted of a polymeric substrate and a brittle film overcoat. The technique is based on a model which assumes a perfectly elastic composite. In the present study, it s shown that as long as only the film component of the composite is brittle, the technique is also applicable to the composites where the substrates may display plastic deformation prior to adhesive failure of the film. Strain measurements, instead of load, eliminate the difficulties introduced by the plastic behavior of the substrate. Experimental work was performed on systems containing brittle amorphous selenium films on aluminum and Mylar substrates. These systems with selenium films were of interest due to their usage in photoreceptor technology

  1. Wind and turbulence measurements by the Middle and Upper Atmosphere Radar (MUR: comparison of techniques

    Directory of Open Access Journals (Sweden)

    A. A. Praskovsky

    2004-11-01

    Full Text Available The structure-function-based method (referred to as UCAR-STARS, a technique for estimating mean horizontal winds, variances of three turbulent velocity components and horizontal momentum flux was applied to the Middle and Upper atmosphere Radar (MUR operating in spaced antenna (SA profiling mode. The method is discussed and compared with the Holloway and Doviak (HAD correlation-function-based technique. Mean horizontal winds are estimated with the STARS and HAD techniques; the Doppler Beam Swinging (DBS method is used as a reference for evaluating the SA techniques. Reasonable agreement between SA and DBS techniques is found at heights from 5km to approximately 11km, where signal-to-noise ratio was rather high. The STARS and HAD produced variances of vertical turbulent velocity are found to be in fair agreement. They are affected by beam-broadening in a different way than the DBS-produced spectral width, and to a much lesser degree. Variances of horizontal turbulent velocity components and horizontal momentum flux are estimated with the STARS method, and strong anisotropy of turbulence is found. These characteristics cannot be estimated with correlation-function-based SA methods, which could make UCAR-STARS a useful alternative to traditional SA techniques.

  2. An efficient similarity measure technique for medical image registration

    Indian Academy of Sciences (India)

    In this paper, an efficient similarity measure technique is proposed for medical image registration. The proposed approach is based on the Gerschgorin circles theorem. In this approach, image registration is carried out by considering Gerschgorin bounds of a covariance matrix of two compared images with normalized ...

  3. Verification of long-term load measurement technique

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe

    storage and 3) data analysis technique to verify design load assumptions. The work is carried out under Contract no 019945 (SES6) "UPWIND" within the European Commission The interaction between the mechanical and electrical generator subsystems is described rudimentarily, based primarily on HAWC2...... simulations below stall of the mechanical system with simple generator and gearbox systems. The electrical system simulations were not carried out as intended in DOW[2], but indications of the conditions for establishing the interaction have been described by measurements and by argument, that this might have...

  4. Progress in automation, robotics and measuring techniques

    CERN Document Server

    Zieliński, Cezary; Kaliczyńska, Małgorzata

    2015-01-01

    This book presents recent progresses in control, automation, robotics, and measuring techniques. It includes contributions of top experts in the fields, focused on both theory and industrial practice. The particular chapters present a deep analysis of a specific technical problem which is in general followed by a numerical analysis and simulation, and results of an implementation for the solution of a real world problem. The presented theoretical results, practical solutions and guidelines will be useful for both researchers working in the area of engineering sciences and for practitioners solving industrial problems.    .

  5. Relations between radiation risks and radiation protection measuring techniques

    International Nuclear Information System (INIS)

    Herrmann, K.; Kraus, W.

    Relations between radiation risks and radiation protection measuring techniques are considered as components of the radiation risk. The influence of the exposure risk on type and extent of radiation protection measurements is discussed with regard to different measuring tasks. Based upon measuring results concerning the frequency of certain external and internal occupational exposures in the GDR, it has been shown that only a small fraction of the monitored persons are subjected to a high exposure risk. As a consequence the following recommendations are presented: occupationally exposed persons with small exposure risk should be monitored using only a long-term desimeter (for instance a thermoluminescence desimeter). In the case of internal exposure, the surface and air contamination levels should be controlled so strictly that routine measurements of internal contamination need not be performed

  6. COMPARi\\ TIVE STUDIES OF TRADITIONAL (NON-ENERG\\T

    African Journals Online (AJOL)

    2012-12-19

    Dec 19, 2012 ... more energy and utilities cost than the traditional energy technique. . " ' .... ,. Keywords: ... An additional major advantage of the Pinch approach is that ... modification before embarking on actual implementation.(Adefila, I 994}.

  7. A COMPARISON OF STELLAR ELEMENTAL ABUNDANCE TECHNIQUES AND MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Hinkel, Natalie R.; Young, Patrick A.; Pagano, Michael D.; Desch, Steven J.; Anbar, Ariel D. [School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287 (United States); Adibekyan, Vardan; Mena, Elisa Delgado; Sousa, Sergio G.; Santos, Nuno C. [Instituto de Astrofísica e Ciências do Espaço, Universidade do Porto, CAUP, Rua das Estrelas, 4150-762 Porto (Portugal); Blanco-Cuaresma, Sergi [Observatoire de Genève, Université de Genève, CH-1290 Versoix (Switzerland); Carlberg, Joleen K. [NASA Goddard Space Flight Center, Code 667, Greenbelt MD 20771 (United States); Liu, Fan [Research School of Astronomy and Astrophysics, Australian National University, Cotter Road, Weston Creek, ACT 2611 (Australia); Nordlander, Thomas; Korn, Andreas; Gruyters, Pieter; Heiter, Ulrike [Department of Physics and Astronomy, Uppsala University, Box 516, 75120 Uppsala (Sweden); Jofré, Paula [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Soubiran, Caroline, E-mail: natalie.hinkel@gmail.com [CNRS/Univ. Bordeaux, LAB, UMR 5804, F-33270, Floirac (France)

    2016-09-01

    Stellar elemental abundances are important for understanding the fundamental properties of a star or stellar group, such as age and evolutionary history, as well as the composition of an orbiting planet. However, as abundance measurement techniques have progressed, there has been little standardization between individual methods and their comparisons. As a result, different stellar abundance procedures determine measurements that vary beyond the quoted error for the same elements within the same stars. The purpose of this paper is to better understand the systematic variations between methods and offer recommendations for producing more accurate results in the future. We invited a number of participants from around the world (Australia, Portugal, Sweden, Switzerland, and the United States) to calculate 10 element abundances (C, O, Na, Mg, Al, Si, Fe, Ni, Ba, and Eu) using the same stellar spectra for four stars (HD 361, HD 10700, HD 121504, and HD 202206). Each group produced measurements for each star using (1) their own autonomous techniques, (2) standardized stellar parameters, (3) a standardized line list, and (4) both standardized parameters and a line list. We present the resulting stellar parameters, absolute abundances, and a metric of data similarity that quantifies the homogeneity of the data. We conclude that standardization of some kind, particularly stellar parameters, improves the consistency between methods. However, because results did not converge as more free parameters were standardized, it is clear there are inherent issues within the techniques that need to be reconciled. Therefore, we encourage more conversation and transparency within the community such that stellar abundance determinations can be reproducible as well as accurate and precise.

  8. Traditional boat-building and navigational techniques of southern Orissa

    Digital Repository Service at National Institute of Oceanography (India)

    Tripati, S.

    of the region. No written records on ancient boatbuilding and navigational aids of the region are available for the reconstruction of the technique of boat-building. Boats of this area have been classified into two categories, namely planked and log boats...

  9. Kinematic measurement from panned cinematography.

    Science.gov (United States)

    Gervais, P; Bedingfield, E W; Wronko, C; Kollias, I; Marchiori, G; Kuntz, J; Way, N; Kuiper, D

    1989-06-01

    Traditional 2-D cinematography has used a stationary camera with its optical axis perpendicular to the plane of motion. This method has constrained the size of the object plane or has introduced potential errors from a small subject image size with large object field widths. The purpose of this study was to assess a panning technique that could overcome the inherent limitations of small object field widths, small object image sizes and limited movement samples. The proposed technique used a series of reference targets in the object field that provided the necessary scales and origin translations. A 102 m object field was panned. Comparisons between criterion distances and film measured distances for field widths of 46 m and 22 m resulted in absolute mean differences that were comparable to that of the traditional method.

  10. Multiscale analysis of heart rate dynamics: entropy and time irreversibility measures.

    Science.gov (United States)

    Costa, Madalena D; Peng, Chung-Kang; Goldberger, Ary L

    2008-06-01

    Cardiovascular signals are largely analyzed using traditional time and frequency domain measures. However, such measures fail to account for important properties related to multiscale organization and non-equilibrium dynamics. The complementary role of conventional signal analysis methods and emerging multiscale techniques, is, therefore, an important frontier area of investigation. The key finding of this presentation is that two recently developed multiscale computational tools--multiscale entropy and multiscale time irreversibility--are able to extract information from cardiac interbeat interval time series not contained in traditional methods based on mean, variance or Fourier spectrum (two-point correlation) techniques. These new methods, with careful attention to their limitations, may be useful in diagnostics, risk stratification and detection of toxicity of cardiac drugs.

  11. Profile and birthing practices of Maranao traditional birth attendants.

    Science.gov (United States)

    Maghuyop-Butalid, Roselyn; Mayo, Norhanifa A; Polangi, Hania T

    2015-01-01

    This study determined the profile and birthing practices in both modern and traditional ways among Maranao traditional birth attendants (TBAs) in Lanao del Norte, Philippines. It employed a descriptive research design. The respondents were 50 Maranao TBAs selected through the snowball sampling technique. A questionnaire was developed by the researchers to identify the respondents' modern birthing practices utilizing the Essential Intrapartum and Newborn Care (EINC) Protocol. To determine their profile and traditional birthing practices, items from a previous study and the respondents' personal claims were adapted. This study shows that Maranao TBAs have less compliance to the EINC Protocol and they often practice the traditional birthing interventions, thus increasing the risk of complications to both mother and newborn.

  12. Correlation between near infrared spectroscopy and electrical techniques in measuring skin moisture content

    International Nuclear Information System (INIS)

    Mohamad, M; Sabbri, A R M; Jafri, M Z Mat; Omar, A F

    2014-01-01

    Near infrared (NIR) spectroscopy technique serves as an important tool for the measurement of moisture content of skin owing to the advantages it has over the other techniques. The purpose of the study is to develop a correlation between NIR spectrometer with electrical conventional techniques for skin moisture measurement. A non-invasive measurement of moisture content of skin was performed on different part of human face and hand under control environment (temperature 21 ± 1 °C, relative humidity 45 ± 5 %). Ten healthy volunteers age between 21-25 (male and female) participated in this study. The moisture content of skin was measured using DermaLab ® USB Moisture Module, Scalar Moisture Checker and NIR spectroscopy (NIRQuest). Higher correlation was observed between NIRQuest and Dermalab moisture probe with a coefficient of determination (R 2 ) above 70 % for all the subjects. However, the value of R 2 between NIRQuest and Moisture Checker was observed to be lower with the R 2 values ranges from 51.6 to 94.4 %. The correlation of NIR spectroscopy technique successfully developed for measuring moisture content of the skin. The analysis of this correlation can help to establish novel instruments based on an optical system in clinical used especially in the dermatology field

  13. Red blood cell-deformability measurement: review of techniques.

    Science.gov (United States)

    Musielak, M

    2009-01-01

    Cell-deformability characterization involves general measurement of highly complex relationships between cell biology and physical forces to which the cell is subjected. The review takes account of the modern technical solutions simulating the action of the force applied to the red blood cell in macro- and microcirculation. Diffraction ektacytometers and rheoscopes measure the mean deformability value for the total red blood cell population investigated and the deformation distribution index of individual cells, respectively. Deformation assays of a whole single cell are possible by means of optical tweezers. The single cell-measuring setups for micropipette aspiration and atomic force microscopy allow conducting a selective investigation of deformation parameters (e.g., cytoplasm viscosity, viscoelastic membrane properties). The distinction between instrument sensitivity to various RBC-rheological features as well as the influence of temperature on measurement are discussed. The reports quoted confront fascinating possibilities of the techniques with their medical applications since the RBC-deformability has the key position in the etiology of a wide range of conditions.

  14. Neutron beam applications; development of texture measuring technique using 1-dimensional PSD

    Energy Technology Data Exchange (ETDEWEB)

    Park, No Jin; Lee, Moon Kyu; Joung, Tae Won; Lee, In Sung [Kumoh National University of Technology, Kumi (Korea)

    2002-03-01

    The new developed materials have often a low crystal symmetry or/and multi-phase state. Because the diffraction patterns of those materials are very complex and some peaks are overlapped, the measured pole figures with a conventional detector (0-dimensional detector) are not sufficient to use for the texture analysis. And also the widely broaden diffraction patterns caused by sever deformation, can only measured with lots of measuring errors using 0-dimensional detector. In this study the 1-dimensional and 2-dimensional position sensitive detector(PSD) is used such pattern to analyse. With PSD the more accurate pole figures can be measured, and the texture analysis, the estimation of the properties are determined more precisely. The measurement using PSD needs special technique for the analysis of the measured pattern. In this study the measuring and analysing technique is developed and compared with the conventional detector. 11 refs., 92 figs., 21 tabs. (Author)

  15. Application of stereo photogrammetric techniques for measuring African Elephants

    Directory of Open Access Journals (Sweden)

    A. J Hall-Martin

    1979-12-01

    Full Text Available Measurements of shoulder height and back length of African elephants were obtained by means of stereo photogrammetric techniques. A pair of Zeiss UMK 10/1318 cameras, mounted on a steel frame on the back of a vehicle, were used to photograph the elephants in the Addo Elephant National Park, Republic of South Africa. Several modifications of normal photogrammetry procedure applicable to the field situation (eg. control points and the computation of results (eg. relative orientation are briefly mentioned. Six elephants were immobilised after being photographed and the measurements obtained from them agreed within a range of 1 cm-10 cm with the photogrammetric measurements.

  16. Exposure measuring techniques for wide band mobile radio-communications

    International Nuclear Information System (INIS)

    Trinchero, S.; Benedetto, A.; Anglesio, L.; D'Amore, G.; Trinchero, D.

    2004-01-01

    The paper illustrates the limits and performances of different experimental monitoring techniques, which are applied to digitally modulated radiofrequency electromagnetic fields used for mobile telecommunications. Different experimental set-ups have been developed, verified and applied for the analysis and characterisation of wide band probes and narrow band measuring procedures. (authors)

  17. A technique of measuring neutron spectrum

    International Nuclear Information System (INIS)

    Sarkar, P.K.; Kirthi, K.N.; Ganguly, A.K.

    1975-01-01

    Plastic scintillators have been used to measure fast neutron spectrum from various sources. Gamma background discrimination has been done by selecting thin scintillators and thereby achieving near 100% transmission of Compton-edge electrons. The measured distribution has been unfolded by using an iterative least square technique. This gives minimum variance and maximum likelihood estimate with error minimised. Smoothening of the observed distribution has been done by Fourier and time series analyses. The method developed is applicable in principle for the determination of spectra of high energy neutrons ranging from 1 MeV to 70 MeV and beyond. However, practical application of the method is limited by the non-availability of cross-section data for various neutron induced reactions with carbon and hydrogen present in the polymerised polystyrene scintillator. This procedure has been adopted in the present work for spectral determination up to 14 MeV neutrons using the published value of reaction and scattering cross-sections. The spectra of Po-Be, Pu-Be, Am-Be and Ra-Be arrived at agree well with the published spectra obtained by other methods. Spectrum from spontaneous fission of Cf-252 have also been measured and fitted to the expression N(E)=Esup(1/2)exp(-E/T). The fitted parameter T and spectral details agree well with those in published literature

  18. Viscosity measurement techniques in Dissipative Particle Dynamics

    Science.gov (United States)

    Boromand, Arman; Jamali, Safa; Maia, Joao M.

    2015-11-01

    In this study two main groups of viscosity measurement techniques are used to measure the viscosity of a simple fluid using Dissipative Particle Dynamics, DPD. In the first method, a microscopic definition of the pressure tensor is used in equilibrium and out of equilibrium to measure the zero-shear viscosity and shear viscosity, respectively. In the second method, a periodic Poiseuille flow and start-up transient shear flow is used and the shear viscosity is obtained from the velocity profiles by a numerical fitting procedure. Using the standard Lees-Edward boundary condition for DPD will result in incorrect velocity profiles at high values of the dissipative parameter. Although this issue was partially addressed in Chatterjee (2007), in this work we present further modifications (Lagrangian approach) to the original LE boundary condition (Eulerian approach) that will fix the deviation from the desired shear rate at high values of the dissipative parameter and decrease the noise to signal ratios in stress measurement while increases the accessible low shear rate window. Also, the thermostat effect of the dissipative and random forces is coupled to the dynamic response of the system and affects the transport properties like the viscosity and diffusion coefficient. We investigated thoroughly the dependency of viscosity measured by both Eulerian and Lagrangian methodologies, as well as numerical fitting procedures and found that all the methods are in quantitative agreement.

  19. Actively stabilized optical fiber interferometry technique for online/in-process surface measurement

    International Nuclear Information System (INIS)

    Wang Kaiwei; Martin, Haydn; Jiang Xiangqian

    2008-01-01

    In this paper, we report the recent progress in optical-beam scanning fiber interferometry for potential online nanoscale surface measurement based on the previous research. It attempts to generate a robust and miniature measurement device for future development into a multiprobe array measurement system. In this research, both fiber-optic-interferometry and the wavelength-division-multiplexing techniques have been used, so that the optical probe and the optical interferometer are well spaced and fast surface scanning can be carried out, allowing flexibility for online measurement. In addition, this system provides a self-reference signal to stabilize the optical detection with high common-mode noise suppression by adopting an active phase tracking and stabilization technique. Low-frequency noise was significantly reduced compared with unstabilized result. The measurement of a sample surface shows an attained repeatability of 3.3 nm

  20. Techniques, processes, and measures for software safety and reliability

    International Nuclear Information System (INIS)

    Sparkman, D.

    1992-01-01

    The purpose of this report is to provide a detailed survey of current recommended practices and measurement techniques for the development of reliable and safe software-based systems. This report is intended to assist the United States Nuclear Reaction Regulation (NRR) in determining the importance and maturity of the available techniques and in assessing the relevance of individual standards for application to instrumentation and control systems in nuclear power generating stations. Lawrence Livermore National Laboratory (LLNL) provides technical support for the Instrumentation and Control System Branch (ICSB) of NRRin advanced instrumentation and control systems, distributed digital systems, software reliability, and the application of verificafion and validafion for the development of software

  1. AUTOMATED TECHNIQUE FOR FLOW MEASUREMENTS FROM MARIOTTE RESERVOIRS.

    Science.gov (United States)

    Constantz, Jim; Murphy, Fred

    1987-01-01

    The mariotte reservoir supplies water at a constant hydraulic pressure by self-regulation of its internal gas pressure. Automated outflow measurements from mariotte reservoirs are generally difficult because of the reservoir's self-regulation mechanism. This paper describes an automated flow meter specifically designed for use with mariotte reservoirs. The flow meter monitors changes in the mariotte reservoir's gas pressure during outflow to determine changes in the reservoir's water level. The flow measurement is performed by attaching a pressure transducer to the top of a mariotte reservoir and monitoring gas pressure changes during outflow with a programmable data logger. The advantages of the new automated flow measurement techniques include: (i) the ability to rapidly record a large range of fluxes without restricting outflow, and (ii) the ability to accurately average the pulsing flow, which commonly occurs during outflow from the mariotte reservoir.

  2. In vivo mitochondrial oxygen tension measured by a delayed fluorescence lifetime technique

    NARCIS (Netherlands)

    Mik, Egbert G.; Johannes, Tanja; Zuurbier, Coert J.; Heinen, Andre; Houben-Weerts, Judith H. P. M.; Balestra, Gianmarco M.; Stap, Jan; Beek, Johan F.; Ince, Can

    2008-01-01

    Mitochondrial oxygen tension (mitoPO(2)) is a key parameter for cellular function, which is considered to be affected under various pathophysiological circumstances. Although many techniques for assessing in vivo oxygenation are available, no technique for measuring mitoPO(2) in vivo exists. Here we

  3. Precision Learning Assessment: An Alternative to Traditional Assessment Techniques.

    Science.gov (United States)

    Caltagirone, Paul J.; Glover, Christopher E.

    1985-01-01

    A continuous and curriculum-based assessment method, Precision Learning Assessment (PLA), which integrates precision teaching and norm-referenced techniques, was applied to a math computation curriculum for 214 third graders. The resulting districtwide learning curves defining average annual progress through the computation curriculum provided…

  4. Applied potential tomography. A new noninvasive technique for measuring gastric emptying

    International Nuclear Information System (INIS)

    Avill, R.; Mangnall, Y.F.; Bird, N.C.; Brown, B.H.; Barber, D.C.; Seagar, A.D.; Johnson, A.G.; Read, N.W.

    1987-01-01

    Applied potential tomography is a new, noninvasive technique that yields sequential images of the resistivity of gastric contents after subjects have ingested a liquid or semisolid meal. This study validates the technique as a means of measuring gastric emptying. Experiments in vitro showed an excellent correlation between measurements of resistivity and either the square of the radius of a glass rod or the volume of water in a spherical balloon when both were placed in an oval tank containing saline. Altering the lateral position of the rod in the tank did not alter the values obtained. Images of abdominal resistivity were also directly correlated with the volume of air in a gastric balloon. Profiles of gastric emptying of liquid meals obtained using applied potential tomography were very similar to those obtained using scintigraphy or dye dilution techniques, provided that acid secretion was inhibited by cimetidine. Profiles of emptying of a mashed potato meal using applied potential tomography were also very similar to those obtained by scintigraphy. Measurements of the emptying of a liquid meal from the stomach were reproducible if acid secretion was inhibited by cimetidine. Thus, applied potential tomography is an accurate and reproducible method of measuring gastric emptying of liquids and particulate food. It is inexpensive, well tolerated, easy to use, and ideally suited for multiple studies in patients, even those who are pregnant

  5. Applied potential tomography. A new noninvasive technique for measuring gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Avill, R.; Mangnall, Y.F.; Bird, N.C.; Brown, B.H.; Barber, D.C.; Seagar, A.D.; Johnson, A.G.; Read, N.W.

    1987-04-01

    Applied potential tomography is a new, noninvasive technique that yields sequential images of the resistivity of gastric contents after subjects have ingested a liquid or semisolid meal. This study validates the technique as a means of measuring gastric emptying. Experiments in vitro showed an excellent correlation between measurements of resistivity and either the square of the radius of a glass rod or the volume of water in a spherical balloon when both were placed in an oval tank containing saline. Altering the lateral position of the rod in the tank did not alter the values obtained. Images of abdominal resistivity were also directly correlated with the volume of air in a gastric balloon. Profiles of gastric emptying of liquid meals obtained using applied potential tomography were very similar to those obtained using scintigraphy or dye dilution techniques, provided that acid secretion was inhibited by cimetidine. Profiles of emptying of a mashed potato meal using applied potential tomography were also very similar to those obtained by scintigraphy. Measurements of the emptying of a liquid meal from the stomach were reproducible if acid secretion was inhibited by cimetidine. Thus, applied potential tomography is an accurate and reproducible method of measuring gastric emptying of liquids and particulate food. It is inexpensive, well tolerated, easy to use, and ideally suited for multiple studies in patients, even those who are pregnant.

  6. Evaluation of Uranium-235 Measurement Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kaspar, Tiffany C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lavender, Curt A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dibert, Mark W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-05-23

    Monolithic U-Mo fuel plates are rolled to final fuel element form from the original cast ingot, and thus any inhomogeneities in 235U distribution present in the cast ingot are maintained, and potentially exaggerated, in the final fuel foil. The tolerance for inhomogeneities in the 235U concentration in the final fuel element foil is very low. A near-real-time, nondestructive technique to evaluate the 235U distribution in the cast ingot is required in order to provide feedback to the casting process. Based on the technical analysis herein, gamma spectroscopy has been recommended to provide a near-real-time measure of the 235U distribution in U-Mo cast plates.

  7. Active and Non-Active Volumetric Information Spaces to Supplement Traditional Rehabilitation

    DEFF Research Database (Denmark)

    Brooks, Anthony Lewis

    2013-01-01

    The purpose of this paper is to inform on findings from a mature body of research titled SoundScapes. The goal was to define, create and question sensor-based ICT systems, techniques and methods to supplement traditional rehabilitation. Following initial biofeedback/sensorimotor tests, a noninvas......The purpose of this paper is to inform on findings from a mature body of research titled SoundScapes. The goal was to define, create and question sensor-based ICT systems, techniques and methods to supplement traditional rehabilitation. Following initial biofeedback/sensorimotor tests...

  8. Measurement of the Dielectric Constant of Seawater at L-Band: Techniques and Measurements

    Science.gov (United States)

    Lang, R.; Utku, C.; Tarkocin, Y.; LeVine, D.

    2009-01-01

    Satellite instruments, that will monitor salinity from space in the near future, require an accurate relationship between salinity/temperature and seawater dielectric constant. This paper will review measurements that were made of the dielectric constant of seawater during the past several years. The objective of the measurements is to determine the dependence of the dielectric constant of seawater on salinity and on temperature, more accurately than in the past. by taking advantage of modem instrumentation. The measurements of seawater permittivity have been performed as a function of salinity and temperature using a transmission resonant cavity technique. The measurements have been made in the salinity range of 10 to 38 psu and in the temperature range of IOU C to 35 C. These results will be useful in algorithm development for sensor systems such as SMOS and Aquarius. The measurement system consists of a brass microwave cavity that is resonant at 1.413 GHz. The seawater is introduced into the cavity through a capillary glass tube having an inner diameter of 0.1 mm. The diameter of the tube has been made very small so that the amount of seawater introduced in the cavity is small - thus maintaining the sensitivity of the measurements and allowing the use of perturbation theory predicting the seawater permittivity. The change in resonant frequency and the change in cavity Q can be used to determine the real and imaginary pare of the dielectric constant of seawater introduced into the slender tube. The microwave measurements are made by an HPS722D network analyzer. The cavity has been immersed in a uateriethylene-glycol bath which is connected to a Lauda circulator. The circulator keeps the brass cavity at a temperature constant to within 0.01 degrees. The system is automated using a Visual Basic program to control the analyzer and to collect the data. The results of the dielectric constant measurements of seawater will be presented. The measurement results will be

  9. Modified grassline technique for orthodontic space closure.

    Science.gov (United States)

    Lohmiller, Rose Marie

    2006-04-01

    Use of traditional orthodontic measures in the periodontally compromised dentition can be problematic. This article describes a variation of the Grassline technique, in which the author uses adhesive bonding to harmoniously re-align malpositioned teeth. In this simple, easy-to-learn technique, a cotton thread is used to achieve orthodontic tooth movement. Initial contact with the saliva causes shrinkage of the thread, exercising a minor force that moves the teeth while allowing enough time for the tissues to regenerate. With this moderate, intermittent force, successful treatment is achieved with minimal risk. Moreover, this orthodontic technique has been associated with an increase in bone volume. This article presents this new technique and details methods for maintaining treatment success. The technique also is compared with an approach described in the literature. Two case reports are presented; the technique is employed in the first to close a diastema in a periodontally compromised dentition and in the second to correct the migration of maxillary and mandibular incisors. Photographs and radiographs show the esthetic improvement achieved in both cases using this technique.

  10. Electron transport measurements in methane using an improved pulsed Townsend technique

    International Nuclear Information System (INIS)

    Hunter, S.R.; Carter, J.G.; Christophorou, L.G.

    1986-01-01

    An improved pulsed Townsend technique for the measurement of electron transport parameters in gases is described. The accuracy and sensitivity of the technique have been investigated by performing, respectively, electron attachment coefficient measurements in pure O 2 over a wide range of E/N at selected O 2 pressures and by determining the electron attachment and ionization coefficients and electron drift velocity in CH 4 over a wide E/N range. Good agreement has been obtained between the present and the previously published electron attachment coefficients in O 2 and for the drift velocity measurements in CH 4 . The data on the electron attachment coefficient in CH 4 (measured for the first time) showed that with the present improved pulsed Townsend method, electron attachment coefficients up to 10 times smaller than the ionization coefficients at a given E/N value can be accurately measured. Our measurements of the electron attachment and ionization coefficients in CH 4 are in good agreement with a Boltzmann equation analysis of the electron gain and loss processes in CH 4 using published electron scattering cross sections for this molecule

  11. A rapid and robust gradient measurement technique using dynamic single-point imaging.

    Science.gov (United States)

    Jang, Hyungseok; McMillan, Alan B

    2017-09-01

    We propose a new gradient measurement technique based on dynamic single-point imaging (SPI), which allows simple, rapid, and robust measurement of k-space trajectory. To enable gradient measurement, we utilize the variable field-of-view (FOV) property of dynamic SPI, which is dependent on gradient shape. First, one-dimensional (1D) dynamic SPI data are acquired from a targeted gradient axis, and then relative FOV scaling factors between 1D images or k-spaces at varying encoding times are found. These relative scaling factors are the relative k-space position that can be used for image reconstruction. The gradient measurement technique also can be used to estimate the gradient impulse response function for reproducible gradient estimation as a linear time invariant system. The proposed measurement technique was used to improve reconstructed image quality in 3D ultrashort echo, 2D spiral, and multi-echo bipolar gradient-echo imaging. In multi-echo bipolar gradient-echo imaging, measurement of the k-space trajectory allowed the use of a ramp-sampled trajectory for improved acquisition speed (approximately 30%) and more accurate quantitative fat and water separation in a phantom. The proposed dynamic SPI-based method allows fast k-space trajectory measurement with a simple implementation and no additional hardware for improved image quality. Magn Reson Med 78:950-962, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Technique to measure contact angle of micro/nanodroplets using atomic force microscopy

    International Nuclear Information System (INIS)

    Jung, Yong Chae; Bhushan, Bharat

    2008-01-01

    Contact angle is the primary parameter that characterizes wetting; however, the measurement techniques have been limited to droplets with a diameter as low as about 50 μm. The authors developed an atomic force microscopy-based technique to measure the contact angle of micro- and nanodroplets deposited using a modified nanoscale dispensing tip. The obtained contact angle results were compared with those of a macrodroplet (2.1 mm diameter). It was found that the contact angle on various surfaces decreases with decreasing the droplet size

  13. The ``hydro-wired``: more than a technique, a global concept; ``L`hydrocable``: plus qu`une technique, un concept global

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1998-09-01

    The ``hydro-wired`` technique consists in the use of small diameter synthetic pipes for the water supply of hot or cold water to space heating or cooling appliances. This new technique has several advantages regarding the thermal comfort and the realization of installations. However cares must be taken during the application of this technique and the design of installations. This paper describes: the French potential market for this technique (heating and cooling floors, traditional heating, sanitary hot water distribution), the characteristics of this technique with respect to traditional techniques (the sheathing of pipes, the specificities of the `octopus`-type distribution), and the design of installations (the different steps: preliminary thermal analysis, realization, start-up and tests). (J.S.)

  14. Measurements of aerosol fluxes to Speulder forest using a micrometeorological technique

    DEFF Research Database (Denmark)

    Gallagher, M.W.; Beswick, K.M.; Duyzer, J.

    1997-01-01

    It has often been stated that micrometeorological and throughfall measurements of dry deposition differ by an order of magnitude with the results being highly variable and difficult to interpret or reconcile. We present measurements by the eddy correlation method of sub-micron aerosol deposition...... to a forest and show that they are large, typically 1 cm s(-1) or more. We compare the measurements with literature values obtained by throughfall and related techniques. The results, rather than being irreconcilable, show a clear and consistent behaviour in deposition velocity across the aerosol size...... spectrum, despite the very different techniques involved. There would appear to be a contradiction with previously assumed model predictions of aerosol deposition Velocity to forests and rough vegetated surfaces particularly for particles in the size range 0.1-1.0 mu m where collection efficiencies appear...

  15. Tracer-based laser-induced fluorescence measurement technique for quantitative fuel/air-ratio measurements in a hydrogen internal combustion engine.

    Science.gov (United States)

    Blotevogel, Thomas; Hartmann, Matthias; Rottengruber, Hermann; Leipertz, Alfred

    2008-12-10

    A measurement technique for the quantitative investigation of mixture formation processes in hydrogen internal combustion engines (ICEs) has been developed using tracer-based laser-induced fluorescence (TLIF). This technique can be employed to fired and motored engine operation. The quantitative TLIF fuel/air-ratio results have been verified by means of linear Raman scattering measurements. Exemplary results of the simultaneous investigation of mixture formation and combustion obtained at an optical accessible hydrogen ICE are shown.

  16. Profile and birthing practices of Maranao traditional birth attendants

    OpenAIRE

    Maghuyop-Butalid, Roselyn; Mayo, Norhanifa A; Polangi, Hania T

    2015-01-01

    Roselyn Maghuyop-Butalid, Norhanifa A Mayo, Hania T Polangi College of Nursing, Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines Abstract: This study determined the profile and birthing practices in both modern and traditional ways among Maranao traditional birth attendants (TBAs) in Lanao del Norte, Philippines. It employed a descriptive research design. The respondents were 50 Maranao TBAs selected through the snowball sampling technique. A quest...

  17. Activities at Forschungszentrum Juelich in Safeguards Analytical Techniques and Measurements

    International Nuclear Information System (INIS)

    Duerr, M.; Knott, A.; Middendorp, R.; Niemeyer, I.; Kueppers, S.; Zoriy, M.; Froning, M.; Bosbach, D.

    2015-01-01

    The application of safeguards by the IAEA involves analytical measurements of samples taken during inspections. The development and advancement of analytical techniques with support from the Member States contributes to strengthened and more efficient verification of compliance with non-proliferation obligations. Since recently, a cooperation agreement has been established between Forschungszentrum Juelich and the IAEA in the field of analytical services. The current working areas of Forschungszentrum Juelich are: (i) Production of synthetic micro-particles as calibration standard and reference material for particle analysis, (ii) qualification of the Forschungszentrum Juelich as a member of the IAEA network of analytical laboratories for safeguards (NWAL), and (iii) analysis of impurities in nuclear material samples. With respect to the synthesis of particles, a dedicated setup for the production of uranium particles is being developed, which addresses the urgent need for material tailored for its use in quality assurance and quality control measures for particle analysis of environmental swipe samples. Furthermore, Forschungszentrum Juelich has been nominated as a candidate laboratory for membership in the NWAL network. To this end, analytical capabilities at Forschungszentrum Juelich have been joined to form an analytical service within a dedicated quality management system. Another activity is the establishment of analytical techniques for impurity analysis of uranium-oxide, mainly focusing on inductively coupled mass spectrometry. This contribution will present the activities at Forschungszentrum Juelich in the area of analytical measurements and techniques for nuclear verification. (author)

  18. Acoustic Measurements in Opera Houses: Comparison Between Different Techniques and Equipment

    Science.gov (United States)

    FAUSTI, P.; FARINA, A.

    2000-04-01

    In room acoustics, many objective parameters to quantify subjective impressions have been introduced. These quantities can be measured by using a wide variety of powerful tools and equipment. The results can be influenced by the measurement techniques and instruments used. Furthermore, the results also depend on the measurement positions and on the condition of the hall (full, empty, etc.). The aim of this work is to define a tightly standardized measurement procedure for the collection of a complete objective description of an opera house's acoustics. In this paper some of the results obtained by the authors after measurements made in three different halls are presented. Comparisons were made both between different hardware and software tools (real-time analyzer, DAT, PC-board, source, microphones, post-processing software) and between different measurement methods (interrupted stationary noise, true-impulse, pseudo-random white noise with impulse-response doconvolution, sine sweep) as well as between different positions in the halls, with and without the presence of musicians and audience. The results have shown that the differences obtained when using different measurement techniques and equipment are not of significant importance. The only effective differences were found regarding the recording techniques, as the monaural measurements give appreciably different results from the average of left and right channel of binaural measurements. Slightly different results were alsofound between true impulsive sources (pistol shots, balloons) and omni-directional (dodecahedral) loudspeakers. Attention must be paid to the signal-to-noise ratio, as this can influence the correct calculation of some acoustical parameters. Some differences, not as great as expected, were found in the results with and without the musicians in the orchestra shell and with and without the audience in the hall. This is probably due to the high sound absorption that is typical in Italian opera

  19. Application of interferometry and Faraday rotation techniques for density measurements on ITER

    International Nuclear Information System (INIS)

    Snider, R.T.; Carlstrom, T.N.; Ma, C.H.; Peebles, W.A.

    1995-01-01

    There is a need for real time, reliable density measurement for density control, compatible with the restricted access and radiation environment on ITER. Line average density measurements using microwave or laser interferometry techniques have proven to be robust and reliable for density control on contemporary tokamaks. In ITER, the large path length, high density and density gradients, limit the wavelength of a probing beam to shorter then about 50 microm due to refraction effects. In this paper the authors consider the design of short wavelength vibration compensated interferometers and Faraday rotation techniques for density measurements on ITER. These techniques allow operation of the diagnostics without a prohibitively large vibration isolated structure and permits the optics to be mounted directly on the radial port plugs on ITER. A beam path designed for 10.6 microm (CO2 laser) with a tangential path through the plasma allows both an interferometer and a Faraday rotation measurement of the line average density with good density resolution while avoiding refraction problems. Plasma effects on the probing beams and design tradeoffs will be discussed along with radiation and long pulse issues. A proposed layout of the diagnostic for ITER will be present

  20. X-ray radiographic technique for measuring density uniformity of silica aerogel

    International Nuclear Information System (INIS)

    Tabata, Makoto; Hatakeyama, Yoshikiyo; Adachi, Ichiro; Morita, Takeshi; Nishikawa, Keiko

    2013-01-01

    This paper proposes a new X-ray radiographic technique for measuring density uniformity of silica aerogels used as radiator in proximity-focusing ring-imaging Cherenkov detectors. To obtain high performance in a large-area detector, a key characteristic of radiator is the density (i.e. refractive index) uniformity of an individual aerogel monolith. At a refractive index of n=1.05, our requirement for the refractive index uniformity in the transverse plane direction of an aerogel tile is |δ(n−1)/(n−1)|<4% in a focusing dual layer radiator (with different refractive indices) scheme. We applied the radiographic technique to evaluate the density uniformity of our original aerogels from a trial production and that of Panasonic products (SP-50) as a reference, and to confirm they have sufficient density uniformity within ±1% along the transverse plane direction. The measurement results show that the proposed technique can quantitatively estimate the density uniformity of aerogels.

  1. Attempts to develop a new nuclear measurement technique of β-glucuronidase levels in biological samples

    International Nuclear Information System (INIS)

    Unak, T.; Avcibasi, U.; Yildirim, Y.; Cetinkaya, B.

    2003-01-01

    β-Glucuronidase is one of the most important hydrolytic enzymes in living systems and plays an essential role in the detoxification pathway of toxic materials incorporated into the metabolism. Some organs, especially liver and some tumour tissues, have high level of β-glucuronidase activity. As a result the enzymatic activity of some kind of tumour cells, the radiolabelled glucuronide conjugates of cytotoxic, as well as radiotoxic compounds have potentially very valuable diagnostic and therapeutic applications in cancer research. For this reason, a sensitive measurement of β-glucuronidase levels in normal and tumour tissues is a very important step for these kinds of applications. According to the classical measurement method of β-glucuronidase activity, in general, the quantity of phenolphthalein liberated from its glucuronide conjugate, i.e. phenolphthalein-glucuronide, by β-glucuronidase has been measured by use of the spectrophotometric technique. The lower detection limit of phenolphthalein by the spectrophotometric technique is about 1-3 mg. This means that the β-glucuronidase levels could not be detected in biological samples having lower levels of β-glucuronidase activity and therefore the applications of the spectrophotometric technique in cancer research are very seriously limited. Starting from this consideration, we recently attempted to develop a new nuclear technique to measure much lower concentrations of β-glucuronidase in biological samples. To improve the detection limit, phenolphthalein-glucuronide and also phenyl-N-glucuronide were radioiodinated with 131 I and their radioactivity was measured by use of the counting technique. Therefore, the quantity of phenolphthalein or aniline radioiodinated with 131 I and liberated by the deglucuronidation reactivity of β-glucuronidase was used in an attempt to measure levels lower than the spectrophotometric measurement technique. The results obtained clearly verified that 0.01 pg level of

  2. Techniques for beam impedance measurements above cutoff

    International Nuclear Information System (INIS)

    Lambertson, G.R.; Jacob, A.F.; Rimmer, R.A.; Voelker, F.

    1990-08-01

    Methods for measuring beam impedance above cutoff have been very limited. For design work on the ALS we have developed two techniques that yield data in the frequency domain with high sensitivity. The first is an extension of the wire method; the second utilizes traveling TM waves to simulate the beam's fields at the wall, and thus avoids the mechanical difficulties of mounting the wire. It is also more sensitive than the other method but the interpretation is complicated by the presence of higher order modes. With either method we were able to detect resonant peaks smaller than 1 Ohm at 10 GHz

  3. Near-field Light Scattering Techniques for Measuring Nanoparticle-Surface Interaction Energies and Forces.

    Science.gov (United States)

    Schein, Perry; Ashcroft, Colby K; O'Dell, Dakota; Adam, Ian S; DiPaolo, Brian; Sabharwal, Manit; Shi, Ce; Hart, Robert; Earhart, Christopher; Erickson, David

    2015-08-15

    Nanoparticles are quickly becoming commonplace in many commercial and industrial products, ranging from cosmetics to pharmaceuticals to medical diagnostics. Predicting the stability of the engineered nanoparticles within these products a priori remains an important and difficult challenge. Here we describe our techniques for measuring the mechanical interactions between nanoparticles and surfaces using near-field light scattering. Particle-surface interfacial forces are measured by optically "pushing" a particle against a reference surface and observing its motion using scattered near-field light. Unlike atomic force microscopy, this technique is not limited by thermal noise, but instead takes advantage of it. The integrated waveguide and microfluidic architecture allow for high-throughput measurements of about 1000 particles per hour. We characterize the reproducibility of and experimental uncertainty in the measurements made using the NanoTweezer surface instrument. We report surface interaction studies on gold nanoparticles with 50 nm diameters, smaller than previously reported in the literature using similar techniques.

  4. Application of neutron backscatter techniques to level measurement problems

    International Nuclear Information System (INIS)

    Leonardi-Cattolica, A.M.; McMillan, D.H.; Telfer, A.; Griffin, L.H.; Hunt, R.H.

    1982-01-01

    We have designed and built portable level detectors and fixed level monitors based on neutron scattering and detection principles. The main components of these devices, which we call neutron backscatter gauges, are a neutron emitting radioisotope, a neutron detector, and a ratemeter. The gauge is a good detector for hydrogen but is much less sensitive to most other materials. This allows level measurements of hydrogen bearing materials, such as hydrocarbons, to be made through the walls of metal vessels. Measurements can be made conveniently through steel walls which are a few inches thick. We have used neutron backscatter gauges in a wide variety of level measurement applications encountered in the petrochemical industry. In a number of cases, the neutron techniques have proven to be superior to conventional level measurement methods, including gamma ray methods

  5. Dimensional measuring techniques in the automotive and aircraft industry

    Science.gov (United States)

    Muench, K. H.; Baertlein, Hugh

    1994-03-01

    Optical tooling methods used in industry are rapidly being replaced by new electronic sensor techniques. The impact of new measuring technologies on the production process has caused major changes on the industrial shop floor as well as within industrial measurement systems. The paper deals with one particular industrial measuring system, the manual theodolite measuring system (TMS), within the aircraft and automobile industry. With TMS, setup, data capture, and data analysis are flexible enough to suit industry's demands regarding speed, accuracy, and mobility. Examples show the efficiency and the wide range of TMS applications. In cooperation with industry, the Video Theodolite System was developed. Its origin, functions, capabilities, and future plans are briefly described. With the VTS a major step has been realized in direction to vision systems for industrial applications.

  6. Image Analysis Technique for Material Behavior Evaluation in Civil Structures

    Science.gov (United States)

    Moretti, Michele; Rossi, Gianluca

    2017-01-01

    The article presents a hybrid monitoring technique for the measurement of the deformation field. The goal is to obtain information about crack propagation in existing structures, for the purpose of monitoring their state of health. The measurement technique is based on the capture and analysis of a digital image set. Special markers were used on the surface of the structures that can be removed without damaging existing structures as the historical masonry. The digital image analysis was done using software specifically designed in Matlab to follow the tracking of the markers and determine the evolution of the deformation state. The method can be used in any type of structure but is particularly suitable when it is necessary not to damage the surface of structures. A series of experiments carried out on masonry walls of the Oliverian Museum (Pesaro, Italy) and Palazzo Silvi (Perugia, Italy) have allowed the validation of the procedure elaborated by comparing the results with those derived from traditional measuring techniques. PMID:28773129

  7. Measurement of moisture depth distribution in composite materials using positron lifetime technique

    International Nuclear Information System (INIS)

    Singh, J.J.; Holt, W.H.; Mock, W. Jr.; Mall, G.H.

    1980-01-01

    Fiber-reinforced resin matrix composites reportedly suffer significant degradation in their mechanical properties when exposed to hot, moist, environments for extended periods. Moisture weakens the fiber matrix bond as well as the matrix shear strength. An important factor in determining the extent of degradation is the depth distribution of moisture in the resin matrix. Despite the importance of measuring moisture distribution and its effects on composite material properties, not enough data are available on suitable nondestructive techniques for detecting and measuring moisture diffusion in organic composite materials. This paper addresses itself to the problem of measuring the moisture content of such materials, with special emphasis on its depth distribution, using positron lifetime technique

  8. Fine-resolution repeat topographic surveying of dryland landscapes using UAS-based structure-from-motion photogrammetry: Assessing accuracy and precision against traditional ground-based erosion measurements

    Science.gov (United States)

    Gillian, Jeffrey K.; Karl, Jason W.; Elaksher, Ahmed; Duniway, Michael C.

    2017-01-01

    Structure-from-motion (SfM) photogrammetry from unmanned aerial system (UAS) imagery is an emerging tool for repeat topographic surveying of dryland erosion. These methods are particularly appealing due to the ability to cover large landscapes compared to field methods and at reduced costs and finer spatial resolution compared to airborne laser scanning. Accuracy and precision of high-resolution digital terrain models (DTMs) derived from UAS imagery have been explored in many studies, typically by comparing image coordinates to surveyed check points or LiDAR datasets. In addition to traditional check points, this study compared 5 cm resolution DTMs derived from fixed-wing UAS imagery with a traditional ground-based method of measuring soil surface change called erosion bridges. We assessed accuracy by comparing the elevation values between DTMs and erosion bridges along thirty topographic transects each 6.1 m long. Comparisons occurred at two points in time (June 2014, February 2015) which enabled us to assess vertical accuracy with 3314 data points and vertical precision (i.e., repeatability) with 1657 data points. We found strong vertical agreement (accuracy) between the methods (RMSE 2.9 and 3.2 cm in June 2014 and February 2015, respectively) and high vertical precision for the DTMs (RMSE 2.8 cm). Our results from comparing SfM-generated DTMs to check points, and strong agreement with erosion bridge measurements suggests repeat UAS imagery and SfM processing could replace erosion bridges for a more synoptic landscape assessment of shifting soil surfaces for some studies. However, while collecting the UAS imagery and generating the SfM DTMs for this study was faster than collecting erosion bridge measurements, technical challenges related to the need for ground control networks and image processing requirements must be addressed before this technique could be applied effectively to large landscapes.

  9. Enhancing the Lecture: Revitalizing the Traditional Format.

    Science.gov (United States)

    Bonwell, Charles C.

    1996-01-01

    The traditional lecture format of college courses can be enhanced by including active learning designed to further course goals of learning knowledge, developing skills, or fostering attitudes. Techniques suggested include using pauses, short writing periods, think-pair-share activities, formative quizzes, lecture summaries, and several assessment…

  10. Comparative CO{sub 2} flux measurements by eddy covariance technique using open- and closed-path gas analysers over the equatorial Pacific Ocean

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Fumiyoshi (Graduate School of Natural Science and Technology, Okayama Univ., Okayama (Japan); Atmosphere and Ocean Research Inst., Univ. of Tokyo, Tokyo (Japan)), Email: fkondo@aori.u-tokyo.ac.jp; Tsukamoto, Osamu (Graduate School of Natural Science and Technology, Okayama Univ., Okayama (Japan))

    2012-04-15

    Direct comparison of airsea CO{sub 2} fluxes by open-path eddy covariance (OPEC) and closed-path eddy covariance (CPEC) techniques was carried out over the equatorial Pacific Ocean. Previous studies over oceans have shown that the CO{sub 2} flux by OPEC was larger than the bulk CO{sub 2} flux using the gas transfer velocity estimated by the mass balance technique, while the CO{sub 2} flux by CPEC agreed with the bulk CO{sub 2} flux. We investigated a traditional conflict between the CO{sub 2} flux by the eddy covariance technique and the bulk CO{sub 2} flux, and whether the CO{sub 2} fluctuation attenuated using the closed-path analyser can be measured with sufficient time responses to resolve small CO{sub 2} flux over oceans. Our results showed that the closed-path analyser using a short sampling tube and a high volume air pump can be used to measure the small CO{sub 2} fluctuation over the ocean. Further, the underestimated CO{sub 2} flux by CPEC due to the attenuated fluctuation can be corrected by the bandpass covariance method; its contribution was almost identical to that of H{sub 2}O flux. The CO{sub 2} flux by CPEC agreed with the total CO{sub 2} flux by OPEC with density correction; however, both of them are one order of magnitude larger than the bulk CO{sub 2} flux

  11. Driver drowsiness detection using behavioral measures and machine learning techniques: A review of state-of-art techniques

    CSIR Research Space (South Africa)

    Ngxande, Mkhuseli

    2017-11-01

    Full Text Available This paper presents a literature review of driver drowsiness detection based on behavioral measures using machine learning techniques. Faces contain information that can be used to interpret levels of drowsiness. There are many facial features...

  12. Free-flight measurement technique in the free-piston high-enthalpy shock tunnel

    Science.gov (United States)

    Tanno, H.; Komuro, T.; Sato, K.; Fujita, K.; Laurence, S. J.

    2014-04-01

    A novel multi-component force-measurement technique has been developed and implemented at the impulse facility JAXA-HIEST, in which the test model is completely unrestrained during the test and thus experiences free-flight conditions for a period on the order of milliseconds. Advantages over conventional free-flight techniques include the complete absence of aerodynamic interference from a model support system and less variation in model position and attitude during the test itself. A miniature on-board data recorder, which was a key technology for this technique, was also developed in order to acquire and store the measured data. The technique was demonstrated in a HIEST wind-tunnel test campaign in which three-component aerodynamic force measurement was performed on a blunted cone of length 316 mm, total mass 19.75 kg, and moment of inertia 0.152 kgm2. During the test campaign, axial force, normal forces, and pitching moment coefficients were obtained at angles of attack from 14° to 32° under two conditions: H0 = 4 MJ/kg, P0 = 14 MPa; and H0 = 16 MJ/kg, P0 = 16 MPa. For the first, low-enthalpy condition, the test flow was considered a perfect gas; measurements were thus directly compared with those obtained in a conventional blow-down wind tunnel (JAXA-HWT2) to evaluate the accuracy of the technique. The second test condition was a high-enthalpy condition in which 85% of the oxygen molecules were expected to be dissociated; high-temperature real-gas effects were therefore evaluated by comparison with results obtained in perfect-gas conditions. The precision of the present measurements was evaluated through an uncertainty analysis, which showed the aerodynamic coefficients in the HIEST low enthalpy test agreeing well with those of JAXA-HWT2. The pitching-moment coefficient, however, showed significant differences between low- and high-enthalpy tests. These differences are thought to result from high-temperature real-gas effects.

  13. Intensity Modulation Techniques for Continuous-Wave Lidar for Column CO2 Measurements

    Science.gov (United States)

    Campbell, J. F.; Lin, B.; Obland, M. D.; Kooi, S. A.; Fan, T. F.; Meadows, B.; Browell, E. V.; Erxleben, W. H.; McGregor, D.; Dobler, J. T.; Pal, S.; O'Dell, C.

    2017-12-01

    Global and regional atmospheric carbon dioxide (CO2) measurements for the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) space mission and the Atmospheric Carbon and Transport (ACT) - America project are critical for improving our understanding of global CO2 sources and sinks. Advanced Intensity-Modulated Continuous-Wave (IM-CW) lidar techniques are investigated as a means of facilitating CO2 measurements from space and airborne platforms to meet the ASCENDS and ACT-America science measurement requirements. In recent numerical, laboratory and flight experiments we have successfully used the Binary Phase Shift Keying (BPSK) and Linear Swept Frequency modulations to uniquely discriminate surface lidar returns from intermediate aerosol and cloud returns. We demonstrate the utility of BPSK to eliminate sidelobes in the range profile as a means of making Integrated Path Differential Absorption (IPDA) column CO2 measurements in the presence of optically thin clouds, thereby eliminating bias errors caused by the clouds. Furthermore, high accuracy and precision ranging to the surface as well as to the top of intermediate cloud layers, which is a requirement for the inversion of column CO2 number density measurements to column CO2 mixing ratios, has been demonstrated using new hyperfine interpolation techniques that take advantage of the periodicity of the modulation waveforms. This approach works well for both BPSK and linear swept-frequency modulation techniques and provides very high (at sub-meter level) range resolution. We compare BPSK to linear swept frequency and introduce a new technique to eliminate sidelobes in situations from linear swept frequency where the SNR is high with results that rival BPSK. We also investigate the effects of non-linear modulators, which can in some circumstances degrade the orthogonality of the waveforms, and show how to avoid this. These techniques are used in a new data processing architecture written in

  14. Tritium measurement technique using ''in-bed'' calorimetry

    International Nuclear Information System (INIS)

    Klein, J.E.; Mallory, M.K.; Nobile, A. Jr.

    1991-01-01

    One of the new technologies that has been introduced to the Savannah River Site (SRS) is the production scale use of metal hydride technology to store, pump, and compress hydrogen isotopes. For tritium stored in metal hydride storage beds, a unique relationship does not exist between the amount of tritium in the bed and the pressure-volume-temperature properties of the hydride material. Determining the amount of tritium in a hydride bed after desorbing the contents of the bed to a tank and performing pressure, volume, temperature, and composition (PVTC) measurements is not practical due to long desorption/absorption times and the inability to remove tritium ''heels'' from the metal hydride materials under normal processing conditions. To eliminate the need to remove tritium from hydride storage beds for measurement purposes, and ''in-bed'' tritium calorimetric measurement technique has been developed. The steady-state temperature rise of a gas stream flowing through a jacketed metal hydride storage bed is measured and correlated with power input to electric heaters used to simulate the radiolytic power generated by the decay of tritium to 3 He. Temperature rise results for prototype metal hydride storage beds and the effects of using different gases in the bed are shown. Linear regression results shows that for 95% confidence intervals, temperature rise measurements can be obtained in 14 hours and have an accuracy of ±1.6% of a tritium filled hydride storage bed

  15. The Visual Analogue Scale for Rating, Ranking and Paired-Comparison (VAS-RRP): A new technique for psychological measurement.

    Science.gov (United States)

    Sung, Yao-Ting; Wu, Jeng-Shin

    2018-04-17

    Traditionally, the visual analogue scale (VAS) has been proposed to overcome the limitations of ordinal measures from Likert-type scales. However, the function of VASs to overcome the limitations of response styles to Likert-type scales has not yet been addressed. Previous research using ranking and paired comparisons to compensate for the response styles of Likert-type scales has suffered from limitations, such as that the total score of ipsative measures is a constant that cannot be analyzed by means of many common statistical techniques. In this study we propose a new scale, called the Visual Analogue Scale for Rating, Ranking, and Paired-Comparison (VAS-RRP), which can be used to collect rating, ranking, and paired-comparison data simultaneously, while avoiding the limitations of each of these data collection methods. The characteristics, use, and analytic method of VAS-RRPs, as well as how they overcome the disadvantages of Likert-type scales, ranking, and VASs, are discussed. On the basis of analyses of simulated and empirical data, this study showed that VAS-RRPs improved reliability, response style bias, and parameter recovery. Finally, we have also designed a VAS-RRP Generator for researchers' construction and administration of their own VAS-RRPs.

  16. Persian fencing techniques

    Directory of Open Access Journals (Sweden)

    Manouchehr Moshtagh Khorasani

    2012-07-01

    Full Text Available There are numerous manuscripts, poems and stories that describe, specifically and in detail, the different techniques used in Persian swordsmanship. The present article explains the origins and the techniques of Persian swordsmanship. The article also describes the traditional code of conduct for Persian warriors. Additionally, it describes an array of techniques that were deployed in actual combat in Iran’s history. Some of these techniques are represented via the miniatures that are reproduced herein. This is the first article on Persian swordsmanship published in any periodical.

  17. A semi-automatic technique for measurement of arterial wall from black blood MRI

    International Nuclear Information System (INIS)

    Ladak, Hanif M.; Thomas, Jonathan B.; Mitchell, J. Ross; Rutt, Brian K.; Steinman, David A.

    2001-01-01

    Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semi-automatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple

  18. Root resistance to cavitation is accurately measured using a centrifuge technique.

    Science.gov (United States)

    Pratt, R B; MacKinnon, E D; Venturas, M D; Crous, C J; Jacobsen, A L

    2015-02-01

    Plants transport water under negative pressure and this makes their xylem vulnerable to cavitation. Among plant organs, root xylem is often highly vulnerable to cavitation due to water stress. The use of centrifuge methods to study organs, such as roots, that have long vessels are hypothesized to produce erroneous estimates of cavitation resistance due to the presence of open vessels through measured samples. The assumption that roots have long vessels may be premature since data for root vessel length are sparse; moreover, recent studies have not supported the existence of a long-vessel artifact for stems when a standard centrifuge technique was used. We examined resistance to cavitation estimated using a standard centrifuge technique and compared these values with native embolism measurements for roots of seven woody species grown in a common garden. For one species we also measured vulnerability using single-vessel air injection. We found excellent agreement between root native embolism and the levels of embolism measured using a centrifuge technique, and with air-seeding estimates from single-vessel injection. Estimates of cavitation resistance measured from centrifuge curves were biologically meaningful and were correlated with field minimum water potentials, vessel diameter (VD), maximum xylem-specific conductivity (Ksmax) and vessel length. Roots did not have unusually long vessels compared with stems; moreover, root vessel length was not correlated to VD or to the vessel length of stems. These results suggest that root cavitation resistance can be accurately and efficiently measured using a standard centrifuge method and that roots are highly vulnerable to cavitation. The role of root cavitation resistance in determining drought tolerance of woody species deserves further study, particularly in the context of climate change. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Intercomparison of rod-worth measurement techniques in a LEU-HTR assembly

    International Nuclear Information System (INIS)

    Williams, T.; Chawla, R.

    1994-01-01

    The measurement of absorber-rod worths in the radial reflector of a LEU-HTR pebble bed system is described. Particular emphasis is placed on the choice of complementary measurement techniques to ensure that sensitivities to systematic errors in the calculated parameters used in the analysis are minimised. (author) 3 figs., 3 tabs., 8 refs

  20. Comparative interpretations of renormalization inversion technique for reconstructing unknown emissions from measured atmospheric concentrations

    Science.gov (United States)

    Singh, Sarvesh Kumar; Kumar, Pramod; Rani, Raj; Turbelin, Grégory

    2017-04-01

    The study highlights a theoretical comparison and various interpretations of a recent inversion technique, called renormalization, developed for the reconstruction of unknown tracer emissions from their measured concentrations. The comparative interpretations are presented in relation to the other inversion techniques based on principle of regularization, Bayesian, minimum norm, maximum entropy on mean, and model resolution optimization. It is shown that the renormalization technique can be interpreted in a similar manner to other techniques, with a practical choice of a priori information and error statistics, while eliminating the need of additional constraints. The study shows that the proposed weight matrix and weighted Gram matrix offer a suitable deterministic choice to the background error and measurement covariance matrices, respectively, in the absence of statistical knowledge about background and measurement errors. The technique is advantageous since it (i) utilizes weights representing a priori information apparent to the monitoring network, (ii) avoids dependence on background source estimates, (iii) improves on alternative choices for the error statistics, (iv) overcomes the colocalization problem in a natural manner, and (v) provides an optimally resolved source reconstruction. A comparative illustration of source retrieval is made by using the real measurements from a continuous point release conducted in Fusion Field Trials, Dugway Proving Ground, Utah.

  1. New measurement techniques correct PU inventory in Japanese reprocessing plant

    International Nuclear Information System (INIS)

    2003-01-01

    Full text: At its briefing to the Japan Atomic Energy Commission on 28 January 2003, the Japan Safeguards Office (JSGO) of the Ministry of Education, Culture, Sports, Science and Technology (MEXT) announced that, due to the introduction of more precise sampling and analytical measurement techniques for measuring plutonium in the high active liquid waste (HALW) storage tanks at the Tokai Reprocessing Plant (TRP), the Japan Nuclear Cycle Development Institute (JNC) is correcting the amount of plutonium declared in past accountancy reports to the IAEA. The corrected amounts are expected to be in line with IAEA's own independent verification data and based on measurement methodologies endorsed by the IAEA. The IAEA has recognized for some time that the amount of nuclear material transferred to waste storage had not been adequately measured in the past and has worked with the facility operators and State authorities to introduce improved measurement techniques. IAEA Director General, Dr. Mohamed ElBaradei stressed however, that 'the Agency remains confident in its conclusion that no nuclear material has been diverted from the facility'. This conclusion is based on a range of activities under the NPT Safeguards Agreement between the Agency and Japan, as well as under the Additional Protocol to that Agreement which gives the Agency broad access to nuclear fuel-cycle related information and locations. TRP, in Tokai-mura, Ibaraki prefecture in Japan, was built in the early 1970s, using 1960s-era design and technology. The IAEA began inspecting the facility in 1977. In its annual evaluation of safeguards implementation, as reported to the IAEA's Board of Governors in the Safeguards Implementation Report, the Secretariat has regularly noted the need for strengthening safeguards implementation at TRP, particularly with respect to procedures used for the measurement of nuclear material in the waste produced. In 1996, Japan and the IAEA reached agreement on IAEA sampling, on a

  2. Signal Morphing techniques and possible application to Higgs properties measurements

    CERN Document Server

    Ecker, Katharina Maria; The ATLAS collaboration

    2016-01-01

    One way of describing deviations from the Standard Model is via Effective Field Theories or pseudo-observables, where higher order operators modify the couplings and the kinematics of the interaction of the Standard Model particles. Generating Monte Carlo events for every testable set of parameters for such a theory would require computing resources beyond the ones currently available in ATLAS. Up to now, Matrix-Element based reweighting techniques have been often used to model Beyond Standard Model process starting from Standard Model simulated events. In this talk, we review the advantages and the limitations of morphing techniques to construct continuous probability model for signal parameters, interpolating between a finite number of distributions obtained from the simulation chain. The technique will be exemplified by searching for deviations from the Standard Model predictions in Higgs properties measurements.

  3. Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs

    International Nuclear Information System (INIS)

    Thomson, J.G.; Kerrigan, C.L.

    1991-01-01

    The hydrogen clearance technique has been used for many years by investigators to determine brain blood flow and has been partially validated in this setting using other methods of blood flow measurement. The method has been modified to allow blood flow measurements in skin, but the accuracy of H2 clearance for measuring skin blood flow has not been determined. Multiple blood flow measurements were performed using H2 clearance and radioactive microspheres on skin flaps and control skin in pigs. On 12 pigs, a total of 117 flap and 42 control skin measurements were available for analysis. There was no significant difference between the two techniques in measuring mean control skin blood flow. In skin flaps, H2 clearance was significantly correlated to microsphere-measured blood flow, but it consistently gave an overestimate. Sources of error may include injury to the tissues by insertion of electrodes, consumption of H2 by the electrodes, or diffusion of H2 from the relatively ischemic flap to its well-vascularized bed. Further studies are necessary to determine the cause of this error and to measure the technique's accuracy in skeletal muscle and other flaps

  4. Proceedings of the symposium on advanced measurement techniques and instrumentation: abstract book

    International Nuclear Information System (INIS)

    Kale, Y.B.; Kushwaha, M.; Somkuwar, S.P.; Ajayakumar, S.; Sampathkumar, R.

    2011-01-01

    In order to consolidate the existing knowledge base and further to focus on the future directions of the field of advanced measurement techniques and instrumentation, Bhabha Atomic Research Centre has organized a three-day symposium on 'Advanced Measurement Techniques and Instrumentation' at Multi Purpose Hall, Training School Hostel, Anushaktinagar, Mumbai during February 02-04, 2011. The symposium is aimed at providing a forum to discuss the emerging trends and challenges ahead in the important area of measurement science and technology. This is a unique symposium, which brings together scientists and engineers from all disciplines and provides them a platform for close interaction to exchange ideas, methodologies and expertise, which is extremely important for synergic growth of this field. The symposium consists of 27 talks, which include keynote address, plenary and invited talks, and 63 contributory papers. The abstracts of these papers are brought to you in this volume. Readers may observe that the scientific programme of the symposium covers a wide ranging issues including advanced scientific concepts in measurements, instrumentation strategies, mathematical techniques and development of devices for applications in fundamental physics, astrophysics, fusion plasmas, nuclear reactors, accelerators, environment, chemical and biological sciences, and national security. Papers relevant to INIS are indexed separately

  5. Cost-effective ERT technique for oil-in-water measurement for offshore hydrocyclone installations

    DEFF Research Database (Denmark)

    Durdevic, Petar; Hansen, Leif; Mai, Christian

    2015-01-01

    The goal of this paper is to introduce and design a cost-effective Oil-in-Water (OiW) measuring instrument, which will be investigated for its value in increasing the efficiency of a deoiling hydrocyclone. The technique investigated is based on Electrical Resistivity Tomography (ERT), which basic...... principle is to measure the resistivity of substances from multiple electrodes and from these measurements create a 2-D image of the oil and gas component in the water. This technique requires the measured components to have different electrical resistances, such as seawater which has a lower electrical...... resistance than hydrocarbon oil and gas. This work involves construction of a pilot plant, for testing the feasibility of ERT for OiW measurements, and further exploring if this measured signal can be applied as a reliable feedback signal in optimization of the hydrocyclone's efficiency. Different algorithms...

  6. Cost-Effective ERT Technique for Oil-in-Water Measurement for Offshore Hydrocyclone Installations

    DEFF Research Database (Denmark)

    Løhndorf, Petar Durdevic; Hansen, Leif; Mai, Christian

    2015-01-01

    The goal of this paper is to introduce and design a cost-effective Oil-in-Water (OiW) measuring instrument, which will be investigated for its value in increasing the efficiency of a deoiling hydrocyclone. The technique investigated is based on Electrical Resistivity Tomography (ERT), which basic...... principle is to measure the resistivity of substances from multiple electrodes and from these measurements create a 2-D image of the oil and gas component in the water. This technique requires the measured components to have different electrical resistances, such as seawater which has a lower electrical...... resistance than hydrocarbon oil and gas. This work involves construction of a pilot plant, for testing the feasibility of ERT for OiW measurements, and further exploring if this measured signal can be applied as a reliable feedback signal in optimization of the hydrocyclone's efficiency. Different algorithms...

  7. The application of a shift theorem analysis technique to multipoint measurements

    OpenAIRE

    M. E. Dieckmann; M. E. Dieckmann; S. C. Chapman

    1999-01-01

    A Fourier domain technique has been proposed previously which, in principle, quantifies the extent to which multipoint in-situ measurements can identify whether or not an observed structure is time stationary in its rest frame. Once a structure, sampled for example by four spacecraft, is shown to be quasi-stationary in its rest frame, the structure's velocity vector can be determined with respect to the sampling spacecraft. We investigate the properties of this technique, wh...

  8. Internal flow measurement in transonic compressor by PIV technique

    Science.gov (United States)

    Wang, Tongqing; Wu, Huaiyu; Liu, Yin

    2001-11-01

    The paper presents some research works conducted in National Key Laboratory of Aircraft Engine of China on the shock containing supersonic flow measurement as well as the internal flow measurement of transoijc compressor by PIC technique. A kind of oil particles in diameter about 0.3 micrometers containing in the flow was discovered to be a very good seed for the PIV measurement of supersonic jet flow. The PIV measurement in over-expanded supersonic free jet and in the flow over wages show a very clear shock wave structure. In the PIV internal flow measurement of transonic compressor a kind of liquid particle of glycol was successful to be used as the seed. An illumination periscope with sheet forming optics was designed and manufactured, it leaded the laser shot generated from an integrate dual- cavity Nd:YAG laser of TSI PIV results of internal flow of an advanced low aspect ratio transonic compressor were shown and discussed briefly.

  9. Mangghuer Embroidery: A Vanishing Tradition

    OpenAIRE

    Aila Pullinen

    2015-01-01

    Aila Pullinen. 2015. Mangghuer Embroidery: A Vanishing Tradition IN Gerald Roche and CK Stuart (eds) Asian Highlands Perspectives 36: Mapping the Monguor, 178-188, 301-332. Visits were undertaken in the years 2001 and 2002 to Minhe Hui and Mangghuer (Tu) Autonomous County, Haidong Municipality, Qinghai Province, China to research and document Mangghuer embroidery. This research is summarized in terms of the history of Mangghuer embroidery, tools and materials, embroidery techniques, embr...

  10. Nuclear radioactive techniques applied to materials research

    CERN Document Server

    Correia, João Guilherme; Wahl, Ulrich

    2011-01-01

    In this paper we review materials characterization techniques using radioactive isotopes at the ISOLDE/CERN facility. At ISOLDE intense beams of chemically clean radioactive isotopes are provided by selective ion-sources and high-resolution isotope separators, which are coupled on-line with particle accelerators. There, new experiments are performed by an increasing number of materials researchers, which use nuclear spectroscopic techniques such as Mössbauer, Perturbed Angular Correlations (PAC), beta-NMR and Emission Channeling with short-lived isotopes not available elsewhere. Additionally, diffusion studies and traditionally non-radioactive techniques as Deep Level Transient Spectroscopy, Hall effect and Photoluminescence measurements are performed on radioactive doped samples, providing in this way the element signature upon correlation of the time dependence of the signal with the isotope transmutation half-life. Current developments, applications and perspectives of using radioactive ion beams and tech...

  11. Review of Micro/Nano Nondestructive Evaluation Technique (II): Measurement of Acoustic Properties

    International Nuclear Information System (INIS)

    Kim, Chung Seok; Park, Ik Keun

    2012-01-01

    The present paper reviews the micro and nano nondestructive evaluation(NDE) technique that is possible to investigate the surface and measure the acoustic properties. The technical theory, features and applications of the ultrasonic atomic force microscopy(UAFM) and scanning acoustic microscopy(SAM) are illustrated. Especially, these technologies are possible to evaluate the mechanical properties in micro/nano structure and surface through the measurement of acoustic properties in addition to the observation of surface and subsurface. Consequently, it is thought that technique developments and applications of these micro/nano NDE in advanced industrial parts together with present nondestructive industry are widely possible hereafter.

  12. The Recommendations for Linear Measurement Techniques on the Measurements of Nonlinear System Parameters of a Joint.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Scott A [Univ. of Maryland Baltimore County (UMBC), Baltimore, MD (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Catalfamo, Simone [Univ. of Stuttgart (Germany); Brake, Matthew R. W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rice Univ., Houston, TX (United States); Schwingshackl, Christoph W. [Imperial College, London (United Kingdom); Reusb, Pascal [Daimler AG, Stuttgart (Germany)

    2017-01-01

    In the study of the dynamics of nonlinear systems, experimental measurements often convolute the response of the nonlinearity of interest and the effects of the experimental setup. To reduce the influence of the experimental setup on the deduction of the parameters of the nonlinearity, the response of a mechanical joint is investigated under various experimental setups. These experiments first focus on quantifying how support structures and measurement techniques affect the natural frequency and damping of a linear system. The results indicate that support structures created from bungees have negligible influence on the system in terms of frequency and damping ratio variations. The study then focuses on the effects of the excitation technique on the response for a linear system. The findings suggest that thinner stingers should not be used, because under the high force requirements the stinger bending modes are excited adding unwanted torsional coupling. The optimal configuration for testing the linear system is then applied to a nonlinear system in order to assess the robustness of the test configuration. Finally, recommendations are made for conducting experiments on nonlinear systems using conventional/linear testing techniques.

  13. Development of a 2D temperature measurement technique for combustion diagnostics using 2-line atomic fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Engstroem, Johan

    2001-01-01

    The present thesis is concerned with the development and application of a novel planar laser-induced fluorescence (PLIF) technique for temperature measurements in a variety of combusting flows. Accurate measurement of temperature is an essential task in combustion diagnostics, since temperature is one of the most fundamental quantities for the characterization of combustion processes. The technique is based on two-line atomic fluorescence (TLAF) from small quantities of atomic indium (In) seeded into the fuel. It has been developed from small-scale experiments in laboratory flames to the point where practical combustion systems can be studied. The technique is conceptually simple and reveals temperature information in the post-flame regions. The viability of the technique has been tested in three extreme measurement situations: in spark ignition engine combustion, in ultra-lean combustion situations such as lean burning aero-engine concepts and, finally, in fuel-rich combustion. TLAF was successfully applied in an optical Sl engine using isooctane as fuel. The wide temperature sensitivity, 700 - 3000 K, of the technique using indium atoms allowed measurements over the entire combustion cycle in the engine to be performed. In applications in lean combustion a potential problem caused by the strong oxidation processes of indium atoms was encountered. This limits measurement times due to deposits of absorbing indium oxide on measurement windows. The seeding requirement is a disadvantage of the technique and can be a limitation in some applications. The results from experiments performed in sooting flames are very promising for thermometry measurements in such environments. Absorption by hydrocarbons and other native species was found to be negligible. Since low laser energies and low seeding concentrations could be used, the technique did not, unlike most other incoherent optical thermometry techniques, suffer interferences from LII of soot particles or LIF from PAH

  14. Measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1976-08-01

    The purpose of this work has been an analysis and evaluation of the state-of-the-art of measurement and instrumentation techniques for monitoring plutonium and uranium particulates released from nuclear facilities. The occurrence of plutonium and uranium in the nuclear fuel cycle, the corresponding potential for releases, associated radiological protection standards and monitoring objectives are discussed. Techniques for monitoring via decay radiation from plutonium and uranium isotopes are presented in detail, emphasizing air monitoring, but also including soil sampling and survey methods. Additionally, activation and mass measurement techniques are discussed. The availability and prevalence of these various techniques are summarized. Finally, possible improvements in monitoring capabilities due to alterations in instrumentation, data analysis, or programs are presented

  15. [Enlightenment of adverse reaction monitoring on safety evaluation of traditional Chinese medicines].

    Science.gov (United States)

    Song, Hai-bo; Du, Xiao-xi; Ren, Jing-tian; Yang, Le; Guo, Xiao-xin; Pang, Yu

    2015-04-01

    The adverse reaction monitoring is important in warning the risks of traditional Chinese medicines at an early stage, finding potential quality problems and ensuring the safe clinical medication. In the study, efforts were made to investigate the risk signal mining techniques in line with the characteristics of traditional Chinese medicines, particularly the complexity in component, processing, compatibility, preparation and clinical medication, find early risk signals of traditional Chinese medicines and establish a traditional Chinese medicine safety evaluation system based on adverse reaction risk signals, in order to improve the target studies on traditional Chinese medicine safety, effective and timely control risks and solve the existing frequent safety issue in traditional Chinese medicines.

  16. Current and Ongoing Internet Crime Tendencies and Techniques. Preventive Legislation Measures in Romania

    Directory of Open Access Journals (Sweden)

    Florin Postolache

    2010-06-01

    Full Text Available Internet crime techniques that pilfer from victims millions each year continue to plague the Internet through a range of methods. Trends and techniques identified by many organizations along with itsdescription are followed by preventative measures that will support you in being informed prior to entering into dealings and transactions over the Internet. Techniques as Auction Fraud, Counterfeit Cashier's Check, Credit Card Fraud, Debt Elimination, Parcel Courier Email Scheme, Employment/Business Opportunities,Escrow Services Fraud, Identity Theft, Internet Extortion, Investment Fraud, Lotteries, Nigerian Letter or "419", Phishing/Spoofing, Ponzi/Pyramid, Reshipping, Spam, Third Party Receiver of Funds are clarified in this paper and, also the internet crime prevention and legislative measures are treated, too.

  17. Primary study on image addition technique in CT measuring used to determine the malalignment of patellofemoral joints

    International Nuclear Information System (INIS)

    Huan Jian; Gong Jianping; Zhu Jianbing; Dong Qirong; Lu Zhian

    2000-01-01

    Objective: To evaluate the use of image addition technique in the field of CT measuring on patellofemoral joints. Method: In contractive condition and relaxant condition of quadriceps, 60 knee joints of 30 patients (47 knee joints accompanied with peri-patellar pain) were examined by CT scanning, and the CT image addition and single technique. Results: In contractive and relaxant condition of quadriceps in the normal group, the difference between index measured by image addition technique were not significant and it was found that demonstrated measurement error of image addition was smaller, but there was significant difference between index measured by single technique, and it suggests that its replication was bad. Conclusion: Use of image addition technique can decrease measurement error and play a important role on accurately determining the malalignment of patellofemoral joints

  18. The impact of business environment changes on recent costing techniques

    Institute of Scientific and Technical Information of China (English)

    林慧涓

    2011-01-01

    1.Introduction The acceleration of globalization and the prosperity of information technology benefit business a great deal.But with the speeding up of economic development,firms are facing more and more pressure from various aspects of their business.The heated debate is on about whether traditional management accounting practices and techniques are irrelevant to the current business environment and this essay will explore the causes for using some traditional management accounting practices and techniques in the current business environment are inappropriate and put forward some contemporary management accounting techniques which is relevant to the current business environment.Thus,the essay will be divided into three sections to discuss the traditional management accounting practices and techniques and contemporary management accounting techniques in current business environment.

  19. Microvascular imaging: techniques and opportunities for clinical physiological measurements

    International Nuclear Information System (INIS)

    Allen, John; Howell, Kevin

    2014-01-01

    The microvasculature presents a particular challenge in physiological measurement because the vessel structure is spatially inhomogeneous and perfusion can exhibit high variability over time. This review describes, with a clinical focus, the wide variety of methods now available for imaging of the microvasculature and their key applications. Laser Doppler perfusion imaging and laser speckle contrast imaging are established, commercially-available techniques for determining microvascular perfusion, with proven clinical utility for applications such as burn-depth assessment. Nailfold capillaroscopy is also commercially available, with significant published literature that supports its use for detecting microangiopathy secondary to specific connective tissue diseases in patients with Raynaud's phenomenon. Infrared thermography measures skin temperature and not perfusion directly, and it has only gained acceptance for some surgical and peripheral microvascular applications. Other emerging technologies including imaging photoplethysmography, optical coherence tomography, photoacoustic tomography, hyperspectral imaging, and tissue viability imaging are also described to show their potential as techniques that could become established tools for clinical microvascular assessment. Growing interest in the microcirculation has helped drive the rapid development in perfusion imaging of the microvessels, bringing exciting opportunities in microvascular research. (topical review)

  20. A Balloon Sounding Technique for Measuring SO2 Plumes

    Science.gov (United States)

    Morris, Gary A.; Komhyr, Walter D.; Hirokawa, Jun; Lefer, Barry; Krotkov, Nicholay; Ngan, Fong

    2010-01-01

    This paper reports on the development of a new technique for inexpensive measurements of SO2 profiles using a modified dual-ozonesonde instrument payload. The presence of SO2 interferes with the standard electrochemical cell (ECC) ozonesonde measurement, resulting in -1 molecule of O3 reported for each molecule of SO2 present (provided [O3] > [SO2]). In laboratory tests, an SO2 filter made with Cr03 placed on the inlet side of the sonde removes nearly 100% of the SO2 present for concentrations up to 60 ppbv and remained effective after exposure to 2.8 X 10(exp 16) molecules of SO2 [equivalent to a column approximately 150 DU (1 DU = 2.69 X 10(exp 20) molecules m(exp -2))]. Flying two ECC instruments on the same payload with one filtered and the other unfiltered yields SO2 profiles, inferred by subtraction. Laboratory tests and field experience suggest an SO2 detection limit of approximately 3 pbb with profiles valid from the surface to the ozonopause [i.e., approximately (8-10 km)]. Two example profiles demonstrate the success of this technique for both volcanic and industrial plumes.

  1. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  2. Developing and Implementing an Assessment Technique to Measure Linked Concepts

    Science.gov (United States)

    Ye, Li; Oueini, Razanne; Lewis, Scott E.

    2015-01-01

    The links students make among chemistry content is considered essential for a robust, enduring understanding in multiple learning theories. This article describes the development and implementation of an assessment technique, termed a Measure of Linked Concepts, designed to inform instructors on students' understanding of linking content…

  3. ACCENT-BIAFLUX workshop 2005, trace gas and aerosol flux measurement and techniques. Abstract book

    Energy Technology Data Exchange (ETDEWEB)

    Werner, A.; Soerensen, L.L. (eds.)

    2005-04-01

    The woorkshop trace gas and aerosol flux measurement techniques in the second meeting within the Biosphere Atmosphere Exchange of Pollutions (BIAFLUX) group in the EU-network project Atmospheric Composition Change (ACCENT). The goal of the workshop is to obtain an overview of techniques for measurements of gas and aerosol fluxes and to gather the knowledge of uncertainties in flux measurements and calculations. The workshop is funded by ACCENT. The abstract book presents abstracts of 21 oral presentations and 26 poster presentations. (LN)

  4. Strain measurement technique

    International Nuclear Information System (INIS)

    1987-01-01

    The 10 contributions are concerned with selected areas of application, such as strain measurements in wood, rubber/metal compounds, sets of strain measurements on buildings, reinforced concrete structures without gaps, pipes buried in the ground and measurements of pressure fluctuations. To increase the availability and safety of plant, stress analyses were made on gas turbine rotors with HT-DMS or capacitive HT-DMS (high temperature strain measurements). (DG) [de

  5. Kalman filtering techniques for reducing variance of digital speckle displacement measurement noise

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ Target dynamics are assumed to be known in measuring digital speckle displacement. Use is made of a simple measurement equation, where measurement noise represents the effect of disturbances introduced in measurement process. From these assumptions, Kalman filter can be designed to reduce variance of measurement noise. An optical and analysis system was set up, by which object motion with constant displacement and constant velocity is experimented with to verify validity of Kalman filtering techniques for reduction of measurement noise variance.

  6. Techniques for Ultra-high Magnetic Field Gradient NMR Diffusion Measurements

    Science.gov (United States)

    Sigmund, Eric E.; Mitrovic, Vesna F.; Calder, Edward S.; Will Thomas, G.; Halperin, William P.; Reyes, Arneil P.; Kuhns, Philip L.; Moulton, William G.

    2001-03-01

    We report on development and application of techniques for ultraslow diffusion coefficient measurements through nuclear magnetic resonance (NMR) in high magnetic field gradients. We have performed NMR experiments in a steady fringe field gradient of 175 T/m from a 23 T resistive Bitter magnet, as well as in a gradient of 42 T/m from an 8 T superconducting magnet. New techniques to provide optimum sensitivity in these experiments are described. To eliminate parasitic effects of the temporal instability of the resistive magnet, we have introduced a passive filter: a highly conductive cryogen-cooled inductive shield. We show experimental demonstration of such a shield’s effect on NMR performed in the Bitter magnet. For enhanced efficiency, we have employed “frequency jumping” in our spectrometer system. Application of these methods has made possible measurements of diffusion coefficients as low as 10-10 cm^2/s, probing motion on a 250 nm length scale.

  7. Measurement of the buccolingual inclination of teeth: manual technique vs 3-dimensional software.

    Science.gov (United States)

    Nouri, Mahtab; Abdi, Amir Hossein; Farzan, Arash; Mokhtarpour, Faraneh; Baghban, AliReza Akbarzadeh

    2014-10-01

    In this study, we aimed to measure the inclination of teeth on dental casts by a manual technique with the tooth inclination protractor (TIP; MBI, Newport, United Kingdom) and a newly designed 3-dimensional (3D) software program. The correlation of the 2 techniques was evaluated, and the reliability of each technique was assessed separately. This study was conducted on 36 dental casts of normal, well-aligned Class I occlusions; we assessed 432 teeth. All casts had a normal Class I occlusion. After determining the facial axis of the clinical crown and the facial axis points on the dental casts, we measured the inclinations of the incisors and posterior teeth up to the first molars in each dental arch relative to Andrews' occlusal plane and the posterior occlusal plane using the TIP. Moreover, the casts were scanned by a structured-light 3D scanner. The inclination of teeth relative to the occlusal plane was determined using the new software. To assess the reliability, measurements of all teeth from 15 casts were repeated twice by the 2 methods. Intraclass correlation coefficient and Dahlberg's formula were used for calculation of correlation and reliability. Overall, the 2 techniques were not significantly different in the measurements of the inclinations of the teeth in both jaws. The ranges of Dahlberg's formula were 3.1° to 5.8° for the maxilla and 3.3° to 5.9° for the mandible. The overall correlation of the 2 techniques according to the intraclass correlation coefficient was 0.91. For calculation of reliability, the intraclass correlation coefficients for the TIP and the 3D method were 0.73 and 0.82, respectively. The TIP and the 3D software showed a high correlation for measurement of the inclinations of maxillary and mandibular teeth relative to the occlusal plane. Also, the reproducibility of the measurements in each method was high. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  8. Stable isotope measurement techniques for atmospheric greenhouse gases

    International Nuclear Information System (INIS)

    2002-01-01

    The technical requirements to perform useful measurements of atmospheric greenhouse gas concentrations and of their isotope ratios are of direct relevance for all laboratories engaged in this field. A meaningful interpretation of isotopes in global models on sources and sinks of CO 2 and other greenhouse gases depends on strict laboratory protocols and data quality control measures ensuring comparable data in time and space. Only with this precondition met, the isotope techniques can serve as a potentially powerful method for reducing uncertainties in the global CO 2 budgets and for tracing pathways and interaction of terrestrial, oceanic, and atmospheric pools of carbon. This publication provides four contributions describing methods for the determination of the isotopic composition of trace gases in atmospheric air and in ice cores. These contributions have been indexed separately

  9. Profile and birthing practices of Maranao traditional birth attendants

    Directory of Open Access Journals (Sweden)

    Maghuyop-Butalid R

    2015-10-01

    Full Text Available Roselyn Maghuyop-Butalid, Norhanifa A Mayo, Hania T Polangi College of Nursing, Mindanao State University-Iligan Institute of Technology, Iligan City, Philippines Abstract: This study determined the profile and birthing practices in both modern and traditional ways among Maranao traditional birth attendants (TBAs in Lanao del Norte, Philippines. It employed a descriptive research design. The respondents were 50 Maranao TBAs selected through the snowball sampling technique. A questionnaire was developed by the researchers to identify the respondents’ modern birthing practices utilizing the Essential Intrapartum and Newborn Care (EINC Protocol. To determine their profile and traditional birthing practices, items from a previous study and the respondents’ personal claims were adapted. This study shows that Maranao TBAs have less compliance to the EINC Protocol and they often practice the traditional birthing interventions, thus increasing the risk of complications to both mother and newborn. Keywords: intrapartum and newborn care, modern birthing practices, traditional birthing practices 

  10. Ultra-small time-delay estimation via a weak measurement technique with post-selection

    International Nuclear Information System (INIS)

    Fang, Chen; Huang, Jing-Zheng; Yu, Yang; Li, Qinzheng; Zeng, Guihua

    2016-01-01

    Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment. (paper)

  11. On the benefit of the negative-spherical-aberration imaging technique for quantitative HRTEM

    International Nuclear Information System (INIS)

    Jia, C.L.; Houben, L.; Thust, A.; Barthel, J.

    2010-01-01

    Employing an aberration corrector in a high-resolution transmission electron microscope, the spherical aberration C S can be tuned to negative values, resulting in a novel imaging technique, which is called the negative C S imaging (NCSI) technique. The image contrast obtained with the NCSI technique is compared quantitatively with the image contrast formed with the traditional positive C S imaging (PCSI) technique. For the case of thin objects negative C S images are superior to positive C S images concerning the magnitude of the obtained contrast, which is due to constructive rather than destructive superposition of fundamental contrast contributions. As a consequence, the image signal obtained with a negative spherical aberration is significantly more robust against noise caused by amorphous surface layers, resulting in a measurement precision of atomic positions which is by a factor of 2-3 better at an identical noise level. The quantitative comparison of the two alternative C S -corrected imaging modes shows that the NCSI mode yields significantly more precise results in quantitative high-resolution transmission electron microscopy of thin objects than the traditional PCSI mode.

  12. Kinematic real-time feedback is more effective than traditional teaching method in learning ankle joint mobilisation: a randomised controlled trial.

    Science.gov (United States)

    González-Sánchez, Manuel; Ruiz-Muñoz, Maria; Ávila-Bolívar, Ana Belén; Cuesta-Vargas, Antonio I

    2016-10-06

    To analyse the effect of real-time kinematic feedback (KRTF) when learning two ankle joint mobilisation techniques comparing the results with the traditional teaching method. Double-blind randomized trial. Faculty of Health Sciences. undergraduate students with no experience in manual therapy. Each student practised intensely for 90 min (45 min for each mobilisation) according to the random methodology assigned (G1: traditional method group and G2: KRTF group). G1: an expert professor supervising the student's practice, the professorstudent ratio was 1:8. G2: placed in front of a station where, while they performed the manoeuvre, they received a KRTF on a laptop. total time of mobilisation, time to reach maximum amplitude, maximum angular displacement in the three axes, maximum and average velocity to reach the maximum angular displacement, average velocity during the mobilisation. Among the pre-post intervention measurements, there were significant differences within the two groups for all outcome variables, however, G2 (KRTF) achieved significantly greater improvements in kinematic parameters for the two mobilisations (significant increase in displacement, velocity and significant reduction in the mobilisations runtime) than G1. Ankle plantar flexion: G1's measurement stability (post-intervention) ranged between 0.491 and 0.687, while G2's measurement stability ranged between 0.899 and 0.984. Ankle dorsal flexion mobilisation: G1 the measurement stability (post-intervention) ranged from 0.543 and 0.684 while G2 ranged between 0.899 and 0.974. KRTF was proven to be more effective tool than traditional teaching method in the teaching - learning process of two joint mobilisation techniques. NCT02504710.

  13. Primary flow and temperature measurements in PWRS using non-invasive techniques

    International Nuclear Information System (INIS)

    Favennec, J.M.; Jossinet, G.; Thomas, P.

    1995-08-01

    PWR primary flow and temperature measurements are classically done with either indirect or invasive techniques. EDF has developed and installed non-invasive innovative techniques on an industrial nuclear power plant (Chooz N1 type PWR). Primary flow-rate is determined by measurement of velocity of primary water in the hot leg: the time fluctuation of γ-ray activity from Nitrogen-16 (produced by neutron activation of 016) is measured outside of the pipe by two specially-designed detectors. The signals from both detectors are then cross-correlated to determine the transit time of primary water between the two detectors; primary flow-rate is then deduced Primary temperature is determined by measurement of sound velocity in hot and cold leg: two pairs of ultrasonic transducers, installed on pipe outer wall, emit pulses periodically, for which the time of flight along the two pipes diameters are determined. The sound velocity thus computed (diameter over time of flight) is then converted into temperature, by use of a calibration formula relating sound velocity to temperature and pressure. This paper addresses metrological and technical aspects of the methods. Experience feedback on industrial PWRs is also presented. (author). 4 refs., 13 figs

  14. Fast sorting measurement technique to determine decontamination priority

    International Nuclear Information System (INIS)

    Distenfeld, C.H.; Brosey, B.; Igarashi, H.

    1986-01-01

    The method used to select decontamination priorities for the Three Mile Island Unit 2 (TMI-2) reactor building (RB) is systematic, but costs in personnel exposure and time must be borne. One way of minimizing exposure is to define and treat the one or two surface sources that are important contributors to the collective dose of the recovery personnel. Surface characteristics can then be determined and decontamination techniques developed to match the removal requirements. At TMI-2, a fast sorting technique was developed and used to prioritize surfaces for exposure reduction. A second quick sort can then be used to determine the next generation of surface characterization, decontamination method selection, and performance. The quick-sort method that was developed is based on the Eberline HP 220A probes directional survey system. The angular response of the HP 220A probes approaches 2 pi steradians and allows toward-away type measurements. Sources distributed over 4 pi steradians are hard to define with this system. Angular differentiation was improved to about pi/2 steradians by redesigning the probe shield. The change allows unambiguous six-direction measurements, such as up, down, front, rear, right, and left with practically no angular overlap or exclusion. A simple, light-weight stand was used to establish an angular reference for the rectangular packaged probe. The six surface planes of the rectangle work with the angular reference to establish the six viewing angles

  15. Measurement of the amplitude and phase transfer functions of an optical modulator using a heterodyne technique

    DEFF Research Database (Denmark)

    Romstad, Francis Pascal; Birkedal, Dan; Mørk, Jesper

    2001-01-01

    We present a new technique that measures the full amplitude and phase transfer curves of the modulator as a function of the applied bias, from which the small signal α-parameter can be calculated. The technique measures the amplitude and phase transfer functions simultaneously and directly......, compared to techniques where a time-consuming data analysis is necessary to calculate the a-parameter and an additional measurement is necessary to estimate the phase. Additionally, the chirp profile for all operation points can be calculated....

  16. Using adapted budget cost variance techniques to measure the impact of Lean – based on empirical findings in Lean case studies

    DEFF Research Database (Denmark)

    Kristensen, Thomas Borup

    2015-01-01

    Lean is dominating management philosophy, but the management accounting techniques that best supports this is still not fully understood. Especially how Lean fits traditional budget variance analysis, which is a main theme of every management accounting textbook. I have studied three Scandinavian...

  17. Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques

    Science.gov (United States)

    Yoon, Jihyung; Heins, David; Zhao, Xiaodong; Sanders, Mary; Zhang, Rui

    2017-12-01

    More and more advanced radiotherapy techniques have been adopted for post-mastectomy radiotherapies (PMRT). Patient dose reconstruction is challenging for these advanced techniques because they increase the low out-of-field dose area while the accuracy of out-of-field dose calculations by current commercial treatment planning systems (TPSs) is poor. We aim to measure and model the out-of-field radiation doses from various advanced PMRT techniques. PMRT treatment plans for an anthropomorphic phantom were generated, including volumetric modulated arc therapy with standard and flattening-filter-free photon beams, mixed beam therapy, 4-field intensity modulated radiation therapy (IMRT), and tomotherapy. We measured doses in the phantom where the TPS calculated doses were lower than 5% of the prescription dose using thermoluminescent dosimeters (TLD). The TLD measurements were corrected by two additional energy correction factors, namely out-of-beam out-of-field (OBOF) correction factor K OBOF and in-beam out-of-field (IBOF) correction factor K IBOF, which were determined by separate measurements using an ion chamber and TLD. A simple analytical model was developed to predict out-of-field dose as a function of distance from the field edge for each PMRT technique. The root mean square discrepancies between measured and calculated out-of-field doses were within 0.66 cGy Gy-1 for all techniques. The IBOF doses were highly scattered and should be evaluated case by case. One can easily combine the measured out-of-field dose here with the in-field dose calculated by the local TPS to reconstruct organ doses for a specific PMRT patient if the same treatment apparatus and technique were used.

  18. A Simple Technique of Supine Craniospinal Irradiation

    International Nuclear Information System (INIS)

    Munshi, Anusheel; Jalali, Rakesh

    2008-01-01

    We describe a simple procedure of craniospinal irradiation in supine position. The procedure was carried out with a 100-cm isocenter linear accelerator and compatible simulator. Treatment was with a 1 or 2 posteroanterior (PA)-directed spinal fields abutting lateral-directed cranial fields. Abutment of the fields was established by placement of markers on the neck of the patient, which provided a measure of the divergence of the spinal field. The precision and reproducibility of this technique, including the placement of junctions, appeared to be as good as for treatment in the prone position. The same could be verified with port films. We conclude that this new technique of supine craniospinal treatment is a simple and convenient alternative to traditional treatment in the prone position

  19. Measurement of radium isotopes with the ANU AMS facility

    International Nuclear Information System (INIS)

    Tims, S.G.; Fifield, L.K.

    2003-01-01

    In contaminated environments the spatial distribution of thorium should be far more uniform than that for uranium. Accordingly, measurements of the 228 Ra/ 226 Ra ratio may provide a probe with which to assess variations in the amount of uranium-process derived 226 Ra. Furthermore, for contaminated or rehabilitated areas where the 226 Ra/ 228 Ra ratio is anomalous, measurements of the transport of material away from the site via the ratio could provide information on the local erosion rate. Accelerator Mass Spectrometry (AMS) adds a tandem ion accelerator and additional analysis stages to a conventional mass spectrometry arrangement, in order to facilitate ultra-trace level abundance measurements of selected isotopes. In doing so, it also makes use of the detection and analysis techniques of traditional nuclear physics. For the 226,228 Ra isotopes AMS offers a number of advantages over the more traditional techniques of a-and γ- spectroscopy. AMS requires less sample mass, and because of its very high selectivity provides excellent discrimination against potential interferences. The smaller sample size (∼1g) also allows a considerable simplification of the radio-chemical processing compared with α-spectroscopy. Two major advantages are the ability to measure both isotopes with the one technique without the necessity of waiting for 228 Th to grow in and, that once prepared, the 228 Ra/ 226 Ra ratio for ∼30 samples can be determined in about a day. This paper will describe the AMS technique, and highlight recent developments in the measurement of 226,228 Ra with the ANU system

  20. Beta activity measurements in high, variable gamma backgrounds

    International Nuclear Information System (INIS)

    Stanga, D.; Sandu, E.; Craciun, L.

    1997-01-01

    In many cases beta activity measurements must be performed in high and variable gamma backgrounds. In such instances it is necessary to use well-shielded detectors but this technique is limited to laboratory equipment and frequently insufficient. In order to perform in a simple manner beta activity measurements in high and variable backgrounds a software-aided counting technique have been developed and a counting system have been constructed. This technique combines the different counting techniques with traditional method of successive measurement of the sample and background. The counting system is based on a programmable multi-scaler which is endowed with appropriate software and allow all operations to be performed via keyboard in an interactive fashion. Two large - area proportional detectors were selected in order to have the same background and the same gamma response within 5%. A program has been developed for the counting data analysis and beta activity computing. The software-aided counting technique has been implemented for beta activity measurement in high and variable backgrounds. (authors)

  1. Measurement and control techniques for electric equipment development; Tecnicas de medicion y control para el desarrollo de equipos electricos

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Neblina, Joaquin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1988-12-31

    In broad outlines the measuring and control techniques that are used in the electric equipment development in the short circuit laboratories, are described. In this article the utilization criteria of the traditional and modern (analogical and digital) instruments are described as well as the tendency towards the system`s integration for the automation of the measurement and control processes. Also, mention is made of the systems currently being developed at the Instituto de Investigaciones Electricas (IIE) to be applied at the Short Circuit Laboratories of Comision Federal de Electricidad (CFE) and of the IIE. [Espanol] Se describen a grandes rasgos las tecnicas de medicion y control que se emplean para el desarrollo de equipos electricos en los laboratorios de corto circuito. En este articulo se describen los criterios de utilizacion de los instrumentos tradicionales y modernos (analogicos y digitales), asi como la tendencia hacia la integracion de sistemas para la automatizacion de los procesos de medicion y control. Tambien se mencionan los sistemas que actualmente se desarrollan en el Instituto de Investigaciones Electricas (IIE) para aplicarlos en los Laboratorios de Corto Circuito de la Comision Federal de Electricidad (CFE) y del Instituto.

  2. Measurement and control techniques for electric equipment development; Tecnicas de medicion y control para el desarrollo de equipos electricos

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Neblina, Joaquin [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    In broad outlines the measuring and control techniques that are used in the electric equipment development in the short circuit laboratories, are described. In this article the utilization criteria of the traditional and modern (analogical and digital) instruments are described as well as the tendency towards the system`s integration for the automation of the measurement and control processes. Also, mention is made of the systems currently being developed at the Instituto de Investigaciones Electricas (IIE) to be applied at the Short Circuit Laboratories of Comision Federal de Electricidad (CFE) and of the IIE. [Espanol] Se describen a grandes rasgos las tecnicas de medicion y control que se emplean para el desarrollo de equipos electricos en los laboratorios de corto circuito. En este articulo se describen los criterios de utilizacion de los instrumentos tradicionales y modernos (analogicos y digitales), asi como la tendencia hacia la integracion de sistemas para la automatizacion de los procesos de medicion y control. Tambien se mencionan los sistemas que actualmente se desarrollan en el Instituto de Investigaciones Electricas (IIE) para aplicarlos en los Laboratorios de Corto Circuito de la Comision Federal de Electricidad (CFE) y del Instituto.

  3. A technique using a stellar spectrographic plate to measure terrestrial ozone column depth

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Alec Y. [Univ. of California, Berkeley, CA (United States)

    1995-08-01

    This thesis examines the feasibility of a technique to extract ozone column depths from photographic stellar spectra in the 5000--7000 Angstrom spectral region. A stellar spectrographic plate is measured to yield the relative intensity distribution of a star`s radiation after transmission through the earth`s atmosphere. The amount of stellar radiation absorbed by the ozone Chappuis band is proportional to the ozone column depth. The measured column depth is within 10% the mean monthly value for latitude 36{degree}N, however the uncertainty is too large to make the measurement useful. This thesis shows that a 10% improvement to the photographic sensitivity uncertainty can decrease the column depth uncertainty to a level acceptable for climatic study use. This technique offers the possibility of measuring past ozone column depths.

  4. An offset tone based gain stabilization technique for mixed-signal RF measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Gopal, E-mail: gjos@barc.gov.in [BARC, Mumbai 400085 (India); Motiwala, Paresh D.; Randale, G.D.; Singh, Pitamber [BARC, Mumbai 400085 (India); Agarwal, Vivek; Kumar, Girish [IIT Bombay, Powai, Mumbai 400076 (India)

    2015-09-21

    This paper describes a gain stabilization technique for a RF signal measurement system. A sinusoidal signal of known amplitude, phase and close enough in frequency is added to the main, to be measured RF signal at the input of the analog section. The system stabilizes this offset tone in the digital domain, as it is sampled at the output of the analog section. This process generates a correction factor needed to stabilize the magnitude of the gain of the analog section for the main RF signal. With the help of a simple calibration procedure, the absolute amplitude of the main RF signal can be measured. The technique is especially suited for a system that processes signals around a single frequency, employs direct signal conversion into the digital domain, and processes subsequent steps in an FPGA. The inherent parallel signal processing in an FPGA-based implementation allows a real time stabilization of the gain. The effectiveness of the technique is derived from the fact, that the gain stabilization stamped to the main RF signal measurement branch requires only a few components in the system to be inherently stable. A test setup, along with experimental results is presented from the field of RF instrumentation for particle accelerators. Due to the availability of a phase synchronized RF reference signal in these systems, the measured phase difference between the main RF and the RF reference is also stabilized using this technique. A scheme of the signal processing is presented, where a moving average filter has been used to filter out not only the unwanted frequencies, but also to separate the main RF signal from the offset tone signal. This is achieved by a suitable choice of sampling and offset tone frequencies. The presented signal processing scheme is suitable to a variety of RF measurement applications.

  5. A scoping review of traditional food security in Alaska.

    Science.gov (United States)

    Walch, Amanda; Bersamin, Andrea; Loring, Philip; Johnson, Rhonda; Tholl, Melissa

    2018-12-01

    Food insecurity is a public health concern. Food security includes the pillars of food access, availability and utilisation. For some indigenous peoples, this may also include traditional foods. To conduct a scoping review on traditional foods and food security in Alaska. Google Scholar and the High North Research Documents were used to search for relevant primary research using the following terms: "traditional foods", "food security", "access", "availability", "utilisation", "Alaska", "Alaska Native" and "indigenous". Twenty four articles from Google Scholar and four articles from the High North Research Documents were selected. The articles revealed three types of research approaches, those that quantified traditional food intake (n=18), those that quantified food security (n=2), and qualitative articles that addressed at least one pillar of food security (n=8). Limited primary research is available on food security in Alaskan. Few studies directly measure food security while most provide a review of food security factors. Research investigating dietary intake of traditional foods is more prevalent, though many differences exist among participant age groups and geographical areas. Future research should include direct measurements of traditional food intake and food security to provide a more complete picture of traditional food security in Alaska.

  6. Experimental comparison of particle interaction measurement techniques using optical traps

    International Nuclear Information System (INIS)

    Koehler, Timothy P.; Grillet, Anne Mary; Brotherton, Christopher M.; Molecke, Ryan A.

    2008-01-01

    Optical tweezers has become a powerful and common tool for sensitive determination of electrostatic interactions between colloidal particles. Recently, two techniques, 'blinking' tweezers and direct force measurements, have become increasingly prevalent in investigations of inter-particle potentials. The 'blinking' tweezers method acquires physical statistics of particle trajectories to determine drift velocities, diffusion coefficients, and ultimately colloidal forces as a function of the center-center separation of two particles. Direct force measurements monitor the position of a particle relative to the center of an optical trap as the separation distance between two continuously trapped particles is gradually decreased. As the particles near each other, the displacement from the trap center for each particle increases proportional to the inter-particle force. Although commonly employed in the investigation of interactions of colloidal particles, there exists no direct comparison of these experimental methods in the literature. In this study, an experimental apparatus was developed capable of performing both methods and is used to quantify electrostatic potentials between particles in several particle/solvent systems. Comparisons are drawn between the experiments conducted using the two measurement techniques, theory, and existing literature. Forces are quantified on the femto-Newton scale and results agree well with literature values

  7. REVIEW ARTICLE: Emission measurement techniques for advanced powertrains

    Science.gov (United States)

    Adachi, Masayuki

    2000-10-01

    Recent developments in high-efficiency low-emission powertrains require the emission measurement technologies to be able to detect regulated and unregulated compounds with very high sensitivity and a fast response. For example, levels of a variety of nitrogen compounds and sulphur compounds should be analysed in real time in order to develop aftertreatment systems to decrease emission of NOx for the lean burning powertrains. Also, real-time information on the emission of particulate matter for the transient operation of diesel engines and direct injection gasoline engines is invaluable. The present paper reviews newly introduced instrumentation for such emission measurement that is demanded for the developments in advanced powertrain systems. They include Fourier transform infrared spectroscopy, mass spectrometry and fast response flame ionization detection. In addition, demands and applications of the fuel reformer developments for fuel cell electric vehicles are discussed. Besides the detection methodologies, sample handling techniques for the measurement of concentrations emitted from low emission vehicles for which the concentrations of the pollutants are significantly lower than the concentrations present in ambient air, are also described.

  8. Application of the can technique and radon gas analyzer for radon exhalation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman E-mail: fazalr@kfupm.edu.sa; Al-Jarallah, M.I.; Musazay, M.S.; Abu-Jarad, F

    2003-12-01

    A passive 'can technique' and an active radon gas analyzer with an emanation container were applied for radon exhalation rate measurements from different construction materials, viz. five marble seven ceramic and 100 granite tiles used in Saudi Arabia. The marble and ceramic tiles did not show detectable radon exhalation using the active radon gas analyzer system. However the granite tiles showed relatively high radon exhalations, indicating a relatively high uranium content. A comparison of the radon exhalation rates measured by the two techniques showed a linear correlation coefficient of 0.57. The radon exhalation rates from the granites varied from 0.02 to 6.58 Bq m{sup -2} h{sup -1} with an average of 1.35{+-}1.40 Bq m{sup -2} h{sup -1}. The geometric mean and the geometric standard deviation of the frequency distribution were found to be 0.80 and 3.1, respectively. The track density found on the nuclear track detectors in the can technique exposed to the granites, having high exhalation rates, varied linearly with exposure time with a linear correlation coefficient of 0.99. This experimental finding agrees with the theoretical prediction. The can technique showed sensitivity to low radon exhalation rates from ceramic, marble and some granite over a period of 2 months, which were not detectable by the active radon gas analyzer system. The reproducibility of data with both measuring techniques was found to be within a 7% deviation.

  9. The potential for upgrading traditional fermented foods through ...

    African Journals Online (AJOL)

    In general, traditional fermented foods are made under primitive conditions, which result in low yield and poor quality. This paper outlines the ... The techniques they use are labour intensive, time consuming and have low productivities, with success depending upon observation of good manufacturing practice. Factors ...

  10. The American Indian: Tradition and Transition through Art.

    Science.gov (United States)

    Zastrow, Leona M.

    The purpose of this teaching guide is to educate middle school students about American Indian culture reflected through Indian art forms. Ten contemporary Native American artists are featured with works representing both traditional and transitional techniques and materials. Represented art forms include beadwork, carvings, basketry, jewelry,…

  11. Wind gust measurements using pulsed Doppler wind-lidar: comparison of direct and indirect techniques

    DEFF Research Database (Denmark)

    The measurements of wind gusts, defined as short duration wind speed maxima, have traditionally been limited by the height that can be reached by weather masts. Doppler lidars can potentially provide information from levels above this and thereby fill this gap in our knowledge. To measure the 3D...... is 3.9 s) which can provide high resolution turbulent measurements, both in the vertical direction, and potentially in the horizontal direction. In this study we explore different strategies of wind lidar measurements to measure the wind speed maxima. We use a novel stochastic turbulence reconstruction...... model, driven by the Doppler lidar measurements, which uses a non-linear particle filter to estimate the small-scale turbulent fluctuations. The first results show that the reconstruction method can reproduce the wind speed maxima measured by the sonic anemometer if a low-pass filter with a cut...

  12. Determination of hydrogen content by neutron techniques

    International Nuclear Information System (INIS)

    Santisteban, J.R.; Granada, J.R.; Mayer, R.E.

    1997-01-01

    The commonly available techniques for the determination of hydrogen dissolved in solids are usually destructive from the point of view of the sample. A new, nondestructive method for this kind of measurements has been developed at our laboratory, with the requirement of improved sensitivity for massive samples. This scattering method is based on the use of epithermal neutrons, and has been implemented through the design and construction of a spectrometer dedicated to that task. In addition, the traditional transmission method has been employed to determine hydrogen content in metals, using the full sub thermal and thermal neutron energy ranges. A pulsed neutron source based on an electron LINAC is employed, together with time-of-flight techniques. In this work we will present some results illustrative of the sensitivity achieved by these neutron techniques in different systems and for a wide range of hydrogen concentrations. (author) [es

  13. An improved technique for non-destructive measurement of the stem ...

    African Journals Online (AJOL)

    It was concluded that the standard volume model based on the non-destructive measurement technique meets the requirements for precision in forest surveys. The precision of the standard volume model for L. gmelinii (a coniferous tree) was superior to that of the model for P. tomentosa (a broad-leaved tree). The electronic ...

  14. Flow-rate measurements in closed-conduits by tracer techniques

    International Nuclear Information System (INIS)

    Lund Plantat, C.

    1982-01-01

    This paper presents the study of the precision obtained measuring flow-rates in closed-conduits by tracer techniques. The flow-rates analyzed were in the range of 10 to 20 l/s and Reynolds numbers from 10 5 to 2 x 10 5 . Tracer used were fluoresceine and In-113 m; and the measurements were performed with the dilution method (punctual and continuous injection) and the Allen method. Precisions for the method of punctual and continuous injections were 6.25% and 9.45% for fluoresceine and 9.3% and 3% for In-113, respectively. For Allen method with In-113 m a precision of 5% was obtained; probably this value was affected by the short distance between detectors. In all cases the error corresponds with the expected value except in one measurement at a 68.3% confidence level. (I.V.)

  15. Digital instantaneous frequency measurement technique utilising high-speed ADC’s and FPGA’s

    CSIR Research Space (South Africa)

    Herselman, PL

    2006-02-27

    Full Text Available This paper presents the Digital Instantaneous Frequency Measurement (DIFM) technique, which can measure the carrier frequency of a received waveform within a fraction of a microsecond. The resulting frequency range, resolution and accuracy...

  16. Thickness measurement for the different metals by using Cs-137 gamma source with gamma transmission technique

    International Nuclear Information System (INIS)

    Bueyuek, B.; Tugrul, B.

    2009-01-01

    The purpose of this study is an experimental analysis of thickness measurement for various metals with the gamma transmission technique using Cs-137 as the radioisotope source. Lead, steel, brass, and aluminum, which are frequently used metals in industry, were chosen for the experiments. As the radioisotope source Cs-137 was preferred for the study since it has long half-life, it is mono energetic, and it penetrates the metals that were studied. Experiments were observed in the constant experimental geometry. Calibration curves for the four metal samples were plotted using the obtained results. To test the plotted calibration curves, counts for determining thickness measurement were collected for each sample and the obtained relative count values were used in conjunction with the plotted calibration curves for each sample to determine its thickness. The thicknesses of the samples have been measured with a micrometer and the results were comparatively analyzed with the measurement results obtained by the gamma transmission technique. The results of the analyses revealed that the thickness measurement values obtained with the gamma transmission technique and the thickness measurement values obtained with the conventional technique significantly converge to each other and the difference between the two values is at an acceptable level. Therefore the reliability of thickness measurements with the gamma transmission technique and the resulting calibration curves have been demonstrated.

  17. 3D interferometric shape measurement technique using coherent fiber bundles

    Science.gov (United States)

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen

    2017-06-01

    In-situ 3-D shape measurements with submicron shape uncertainty of fast rotating objects in a cutting lathe are expected, which can be achieved by simultaneous distance and velocity measurements. Conventional tactile methods, coordinate measurement machines, only support ex-situ measurements. Optical measurement techniques such as triangulation and conoscopic holography offer only the distance, so that the absolute diameter cannot be retrieved directly. In comparison, laser Doppler distance sensors (P-LDD sensor) enable simultaneous and in-situ distance and velocity measurements for monitoring the cutting process in a lathe. In order to achieve shape measurement uncertainties below 1 μm, a P-LDD sensor with a dual camera based scattered light detection has been investigated. Coherent fiber bundles (CFB) are employed to forward the scattered light towards cameras. This enables a compact and passive sensor head in the future. Compared with a photo detector based sensor, the dual camera based sensor allows to decrease the measurement uncertainty by the order of one magnitude. As a result, the total shape uncertainty of absolute 3-D shape measurements can be reduced to about 100 nm.

  18. Constructional Efficiency in Al_Ahwaar Traditional Architecture

    Directory of Open Access Journals (Sweden)

    Usama Abdul-Mun'em Khuraibet

    2016-03-01

    Full Text Available Constructional Efficiency in architecture in general is one of the most important standard success for any structure and a measure of its continuity and relevance across time and space. Given the importance of Al-Ahwaar environment that owned the spatial, environmental, economic and social elements had a prominent impact in creation of architecture patterns form to create special architectural and structural environment, which had many qualities and ingredients that contributed to its continuity and existence over the years. From the premise that man and his environment is the main goal to any architectural style, Thus the research problem focusing on the lack of clarity of the previous literatures in its studies for the role of architectural styles in Al-Ahwaar in achieving constructional efficiency, despite the large number of studies on Al-Ahwaar architecture but it is mostly marked by non-clarity and lack in the constructional and technical aspects, Therefore, the research goal focusing on clarification of the impact of the techniques that used in formations Al_Ahwaar traditional architecture in order to reach to the constructional efficiency in various aspects such as technical, material, economical, and expressional. Assuming that achieving to the constructional efficiency at Al-Ahwaar traditional architecture depends on its characteristics and elements that contributed to the continuity of their patterns across time. The research depended on analytical method of a model of traditional architecture in Al-Ahwaar to reach those goals, as the study of these items aims to deepen the understanding of the designer to the requirements of each component in order to achieve integration together. These components must not conflict with each other, but it must be integrated during and after the design process until it comes out as a creative of architectural destination. al-ahwaar architecture, constructional efficiency, technical and material

  19. Equilibrium gas-oil ratio measurements using a microfluidic technique.

    Science.gov (United States)

    Fisher, Robert; Shah, Mohammad Khalid; Eskin, Dmitry; Schmidt, Kurt; Singh, Anil; Molla, Shahnawaz; Mostowfi, Farshid

    2013-07-07

    A method for measuring the equilibrium GOR (gas-oil ratio) of reservoir fluids using microfluidic technology is developed. Live crude oils (crude oil with dissolved gas) are injected into a long serpentine microchannel at reservoir pressure. The fluid forms a segmented flow as it travels through the channel. Gas and liquid phases are produced from the exit port of the channel that is maintained at atmospheric conditions. The process is analogous to the production of crude oil from a formation. By using compositional analysis and thermodynamic principles of hydrocarbon fluids, we show excellent equilibrium between the produced gas and liquid phases is achieved. The GOR of a reservoir fluid is a key parameter in determining the equation of state of a crude oil. Equations of state that are commonly used in petroleum engineering and reservoir simulations describe the phase behaviour of a fluid at equilibrium state. Therefore, to accurately determine the coefficients of an equation of state, the produced gas and liquid phases have to be as close to the thermodynamic equilibrium as possible. In the examples presented here, the GORs measured with the microfluidic technique agreed with GOR values obtained from conventional methods. Furthermore, when compared to conventional methods, the microfluidic technique was simpler to perform, required less equipment, and yielded better repeatability.

  20. Development of ultrasonic technique for measure of porosity of UO2 pellets

    International Nuclear Information System (INIS)

    Baroni, Douglas Brandao

    2008-01-01

    The characterization of nuclear fuel is of great importance to guarantee the efficiency and even the safety in the power stations. At present, the techniques used implicate elevated costs with equipment, materials and installations of radiological protection. Besides, because of being destructive techniques, they impose that the checking of the characteristics of this material is done by sampling. In this work a not destructive technique was developed for measures of porosity in ceramic materials with efficiency and precision. The objective of this work is to this technique will be able to be used in laboratory practice for measures in UO 2 pellets, so it would become viable the inspection of up to 100% of the nuclear fuel, guaranteeing bigger control of the characteristics of the used material, turning in increasing safety, efficiency and economy. The innovation of the technique is due to the fact of analysing the specter of frequency of the ultrasonic wrist, and not his time of course in the material, frequently used. In this work 40 ceramic pellets of alumina were used with values of porosity between 5,09% and 37,30%. A system of recognition of signs using artificial neural networks made possible to distinguish pellets with differences of porosity of 0,04%. It was observed that this technique can be used for several others aims, for example, in the determination of the void fraction in regimen of two-phase flow, what is very important to guarantee the efficiency and safety of nuclear reactors. (author)

  1. Nondestructive evaluation of reinforced plastics by a radiometric measurement technique

    International Nuclear Information System (INIS)

    Entine, Gerald; Afshari, Sia; Verlinden, Matt

    1990-01-01

    The demand for new high-performance plastics has greatly increased with advances in the performance characteristics of sophisticated reinforced engineering resins. However, conventional methods for the evaluation of the glass and filler contents of reinforced plastics are destructive, labor intensive, and time consuming. We have developed a new instrument, to address this problem, which provides for the rapid, accurate, and nondestructive measurement of glass or filler content in reinforced plastics. This instrument utilizes radiation transmission and scattering techniques for analytical measurement of glass, graphite and other fillers used in reinforced plastics. (author)

  2. An in vivo technique for the measurement of bone blood flow in animals

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; DeLuca, P.M. Jr.; Pearson, D.W.; Nickles, R.J.; Lehner, C.E.; Lanphier, E.H.

    1987-01-01

    A new technique to measure the in vivo clearance of 41 Ar from the bone mineral matrix is demonstrated following fast neutron production of 41 Ar in bone via the 44 Ca(n,α) reaction at 14.1 MeV. At the end of irradiation, the 41 Ar activity is assayed with a Ge(Li) detector where sequential gamma-ray spectra are taken. Following full-energy peak integration, background and dead time correction, the activity of 41 Ar as a function of time is determined. Results indicated that the Ar washout from bone in rats using this technique was approximately 16 ml (100 ml min) -1 and in agreement with other measurement techniques. For sheep the bone perfusion in the tibia was approximately 1.9+-0.2 ml (100 ml min) -1 . (author)

  3. A new technique to measure fission-product diffusion coefficients in UO2 fuel

    International Nuclear Information System (INIS)

    Hocking, W.H.; Verrall, R.A.; Bushby, S.J.

    1999-01-01

    This paper describes a new out-reactor technique for the measurement of fission-product diffusion rates in UO 2 . The technique accurately simulates in-reactor fission-fragment effects: a thermal diffusion that is due to localized mixing in the fission track, radiation-enhanced diffusion that is due to point-defect creation by fission fragments, and bubble resolution. The technique utilizes heavy-ion accelerators - low energy (40 keV to 1 MeV) for fission-product implantation, high energy (72 MeV) to create fission-fragment damage effects, and secondary ion mass spectrometry (SIMS) for measuring the depth profile of the implanted species. Preliminary results are presented from annealing tests (not in the 72 MeV ion flux) at 1465 deg. C and 1650 deg. C at low and high concentrations of fission products. (author)

  4. Preserving traditional medical knowledge through modes of transmission: A post-positivist enquiry

    Directory of Open Access Journals (Sweden)

    Janet Adekannbi

    2014-11-01

    Objectives: This study investigated the role which the mode of transmission plays in the preservation of traditional medical knowledge. Method: A post-positivist methodology was adopted. A purposive sampling technique was used to select three communities from each of the six states in South-Western Nigeria. The snowball technique was used in selecting 228 traditional medical practitioners, whilst convenience sampling was adopted in selecting 529 apprentices and 120 children who were not learning the profession. A questionnaire with a five-point Likert scale, key-informant interviews and focus-group discussions were used to collect data. The quantitative data was analysed using descriptive statistics whilst qualitative data was analysed thematically. Results: The dominant mode of knowledge transmission was found to be oblique (66.5% whilst vertical transmission (29.3% and horizontal transmission (4.2% occurred much less. Conclusion: Traditional medical knowledge is at risk of being lost in the study area because most of the apprentices were children from other parents, whereas most traditional medical practitioners preferred to transmit knowledge only to their children.

  5. Middle Byzantine Historiography: Tradition, Innovation, and Reception

    Directory of Open Access Journals (Sweden)

    Staffan Wahlgren

    2015-10-01

    Full Text Available This paper provides an overview of Greek historical writing of the Middle Byzantine period (approx. 800 until 1000 A.D., with a particular focus on the major chronicles, such as Theophanesthe Confessor (early 9th c., George the Monk (probably late 9th c., and Symeon the Logothete (second half of the 10th c.. On the one hand, it is discussed how the chroniclers engage with tradition and either accept it or reject it. Acceptance of tradition is illustrated by many cases where chroniclers keep very close to the narrative modes of their predecessors and in particular where they copy them extensively. Rejection of, or at least deviation from tradition is illustrated by many cases where new narrative techniques and modes of expression are apparent. Particular attention is paid to some aspects of narrative technique which seem to be innovative. In short, there seems to be an increased tendency towards greater logical (and hence, narrative coherence in the chronicles and an increased tendency towards concentration on a small number of settings, issues and persons (in particular, there is an increased concentration on the Capital of Constantinople and the Emperor’s person. Further, reception is discussed, and especially how Middle Byzantine historical texts were read and used in later writings, including the Slavic literatures. The need for further research in order to understand the transmission processes, especially in the form of the philological study of manuscripts, is stressed.

  6. Automatic ultrasound technique to measure angle of progression during labor.

    Science.gov (United States)

    Conversano, F; Peccarisi, M; Pisani, P; Di Paola, M; De Marco, T; Franchini, R; Greco, A; D'Ambrogio, G; Casciaro, S

    2017-12-01

    To evaluate the accuracy and reliability of an automatic ultrasound technique for assessment of the angle of progression (AoP) during labor. Thirty-nine pregnant women in the second stage of labor, with fetus in cephalic presentation, underwent conventional labor management with additional translabial sonographic examination. AoP was measured in a total of 95 acquisition sessions, both automatically by an innovative algorithm and manually by an experienced sonographer, who was blinded to the algorithm outcome. The results obtained from the manual measurement were used as the reference against which the performance of the algorithm was assessed. In order to overcome the common difficulties encountered when visualizing by sonography the pubic symphysis, the AoP was measured by considering as the symphysis landmark its centroid rather than its distal point, thereby assuring high measurement reliability and reproducibility, while maintaining objectivity and accuracy in the evaluation of progression of labor. There was a strong and statistically significant correlation between AoP values measured by the algorithm and the reference values (r = 0.99, P < 0.001). The high accuracy provided by the automatic method was also highlighted by the corresponding high values of the coefficient of determination (r 2  = 0.98) and the low residual errors (root mean square error = 2°27' (2.1%)). The global agreement between the two methods, assessed through Bland-Altman analysis, resulted in a negligible mean difference of 1°1' (limits of agreement, 4°29'). The proposed automatic algorithm is a reliable technique for measurement of the AoP. Its (relative) operator-independence has the potential to reduce human errors and speed up ultrasound acquisition time, which should facilitate management of women during labor. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

  7. Techniques for intense-proton-beam profile measurements

    International Nuclear Information System (INIS)

    Gilpatrick, J.D.

    1998-01-01

    In a collaborative effort with industry and several national laboratories, the Accelerator Production of Tritium (APT) facility and the Spallation Neutron Source (SNS) linac are presently being designed and developed at Los Alamos National Laboratory (LANL). The APT facility is planned to accelerate a 100-mA H + cw beam to 1.7 GeV and the SNS linac is planned to accelerate a 1- to 4-mA-average, H - , pulsed-beam to 1 GeV. With typical rms beam widths of 1- to 3-mm throughout much of these accelerators, the maximum average-power densities of these beams are expected to be approximately 30- and 1-MW-per-square millimeter, respectively. Such power densities are too large to use standard interceptive techniques typically used for acquisition of beam profile information. This paper summarizes the specific requirements for the beam profile measurements to be used in the APT, SNS, and the Low Energy Development Accelerator (LEDA)--a facility to verify the operation of the first 20-MeV section of APT. This paper also discusses the variety of profile measurement choices discussed at a recent high-average-current beam profile workshop held in Santa Fe, NM, and will present the present state of the design for the beam profile measurements planned for APT, SNS, and LEDA

  8. Microrheometric upconversion-based techniques for intracellular viscosity measurements

    Science.gov (United States)

    Rodríguez-Sevilla, Paloma; Zhang, Yuhai; de Sousa, Nuno; Marqués, Manuel I.; Sanz-Rodríguez, Francisco; Jaque, Daniel; Liu, Xiaogang; Haro-González, Patricia

    2017-08-01

    Rheological parameters (viscosity, creep compliance and elasticity) play an important role in cell function and viability. For this reason different strategies have been developed for their study. In this work, two new microrheometric techniques are presented. Both methods take advantage of the analysis of the polarized emission of an upconverting particle to determine its orientation inside the optical trap. Upconverting particles are optical materials that are able to convert infrared radiation into visible light. Their usefulness has been further boosted by the recent demonstration of their three-dimensional control and tracking by single beam infrared optical traps. In this work it is demonstrated that optical torques are responsible of the stable orientation of the upconverting particle inside the trap. Moreover, numerical calculations and experimental data allowed to use the rotation dynamics of the optically trapped upconverting particle for environmental sensing. In particular, the cytoplasm viscosity could be measured by using the rotation time and thermal fluctuations of an intracellular optically trapped upconverting particle, by means of the two previously mentioned microrheometric techniques.

  9. Software development with two port calibration techniques for RHIC impedance measurements

    International Nuclear Information System (INIS)

    Mane, V.; Shea, T.

    1993-01-01

    The coupling impedance of accelerator devices is measured by simulating the beam with a central wire and measuring the scattering parameters of the system. The wire pipe system forms a mismatch with the 50 ohm transmission line. An integrated software environment has been developed in LabVIEW, for the Macintosh. The program measures the scattering parameters of some known standards, determines the connect scattering parameters of a device using TRL calibration technique and gives the impedance of the device. Its performance has been tested for some known microwave devices

  10. Flowing dusty plasma experiments: generation of flow and measurement techniques

    Science.gov (United States)

    Jaiswal, S.; Bandyopadhyay, P.; Sen, A.

    2016-12-01

    A variety of experimental techniques for the generation of subsonic/supersonic dust fluid flows and means of measuring such flow velocities are presented. The experiments have been carried out in a \\Pi -shaped dusty plasma experimental device with micron size kaolin/melamine formaldehyde particles embedded in a background of argon plasma created by a direct current glow discharge. A stationary dust cloud is formed over the cathode region by precisely balancing the pumping speed and gas flow rate. A flow of dust particles/fluid is generated by additional gas injection from a single or dual locations or by altering the dust confining potential. The flow velocity is then estimated by three different techniques, namely, by super particle identification code, particle image velocimetry analysis and the excitation of dust acoustic waves. The results obtained from these three different techniques along with their merits and demerits are discussed. An estimation of the neutral drag force responsible for the generation as well as the attenuation of the dust fluid flow is made. These techniques can be usefully employed in laboratory devices to investigate linear and non-linear collective excitations in a flowing dusty plasma.

  11. RF measurements I: signal receiving techniques

    CERN Document Server

    Caspers, F

    2011-01-01

    For the characterization of components, systems and signals in the RF and microwave range, several dedicated instruments are in use. In this paper the fundamentals of the RF-signal sampling technique, which has found widespread applications in 'digital' oscilloscopes and sampling scopes, are discussed. The key element in these front-ends is the Schottky diode which can be used either as an RF mixer or as a single sampler. The spectrum analyser has become an absolutely indispensable tool for RF signal analysis. Here the front-end is the RF mixer as the RF section of modern spectrum analysers has a rather complex architecture. The reasons for this complexity and certain working principles as well as limitations are discussed. In addition, an overview of the development of scalar and vector signal analysers is given. For the determination of the noise temperature of a one-port and the noise figure of a two-port, basic concepts and relations are shown. A brief discussion of commonly used noise measurement techniq...

  12. Certification of temperature measuring techniques at thermal and nuclear power plants

    International Nuclear Information System (INIS)

    Preobrazhenskij, V.P.; Strigina, L.A.

    1980-01-01

    Necessity for metrological certification of temperature measurement techniques (TMT) at thermal and nuclear energy plants is grounded. An order of TMT certification is stated and formulae for determining the accuracy of temperature measurements by the thermoelectric method are given. It is concluded that through there are also statistical characteristics of errors of a number of measurement properties, it is necessary to carry on statistical investigations into errors of thermoelectrode extending wires, planimeters, measurement conditions. Such kind investigation technigues have been developed. Besides, it is necessary to regulate a uniform approach to the usage of statistical characteristics of errors of means and conditions of measurements to minimize volume of work for the personnel of thermal and nuclear energy plants and provide reliable estimates of temperature measurement errors

  13. Adaptive digital fringe projection technique for high dynamic range three-dimensional shape measurement.

    Science.gov (United States)

    Lin, Hui; Gao, Jian; Mei, Qing; He, Yunbo; Liu, Junxiu; Wang, Xingjin

    2016-04-04

    It is a challenge for any optical method to measure objects with a large range of reflectivity variation across the surface. Image saturation results in incorrect intensities in captured fringe pattern images, leading to phase and measurement errors. This paper presents a new adaptive digital fringe projection technique which avoids image saturation and has a high signal to noise ratio (SNR) in the three-dimensional (3-D) shape measurement of objects that has a large range of reflectivity variation across the surface. Compared to previous high dynamic range 3-D scan methods using many exposures and fringe pattern projections, which consumes a lot of time, the proposed technique uses only two preliminary steps of fringe pattern projection and image capture to generate the adapted fringe patterns, by adaptively adjusting the pixel-wise intensity of the projected fringe patterns based on the saturated pixels in the captured images of the surface being measured. For the bright regions due to high surface reflectivity and high illumination by the ambient light and surfaces interreflections, the projected intensity is reduced just to be low enough to avoid image saturation. Simultaneously, the maximum intensity of 255 is used for those dark regions with low surface reflectivity to maintain high SNR. Our experiments demonstrate that the proposed technique can achieve higher 3-D measurement accuracy across a surface with a large range of reflectivity variation.

  14. A reference data set for validating vapor pressure measurement techniques: homologous series of polyethylene glycols

    Science.gov (United States)

    Krieger, Ulrich K.; Siegrist, Franziska; Marcolli, Claudia; Emanuelsson, Eva U.; Gøbel, Freya M.; Bilde, Merete; Marsh, Aleksandra; Reid, Jonathan P.; Huisman, Andrew J.; Riipinen, Ilona; Hyttinen, Noora; Myllys, Nanna; Kurtén, Theo; Bannan, Thomas; Percival, Carl J.; Topping, David

    2018-01-01

    To predict atmospheric partitioning of organic compounds between gas and aerosol particle phase based on explicit models for gas phase chemistry, saturation vapor pressures of the compounds need to be estimated. Estimation methods based on functional group contributions require training sets of compounds with well-established saturation vapor pressures. However, vapor pressures of semivolatile and low-volatility organic molecules at atmospheric temperatures reported in the literature often differ by several orders of magnitude between measurement techniques. These discrepancies exceed the stated uncertainty of each technique which is generally reported to be smaller than a factor of 2. At present, there is no general reference technique for measuring saturation vapor pressures of atmospherically relevant compounds with low vapor pressures at atmospheric temperatures. To address this problem, we measured vapor pressures with different techniques over a wide temperature range for intercomparison and to establish a reliable training set. We determined saturation vapor pressures for the homologous series of polyethylene glycols (H - (O - CH2 - CH2)n - OH) for n = 3 to n = 8 ranging in vapor pressure at 298 K from 10-7 to 5×10-2 Pa and compare them with quantum chemistry calculations. Such a homologous series provides a reference set that covers several orders of magnitude in saturation vapor pressure, allowing a critical assessment of the lower limits of detection of vapor pressures for the different techniques as well as permitting the identification of potential sources of systematic error. Also, internal consistency within the series allows outlying data to be rejected more easily. Most of the measured vapor pressures agreed within the stated uncertainty range. Deviations mostly occurred for vapor pressure values approaching the lower detection limit of a technique. The good agreement between the measurement techniques (some of which are sensitive to the mass

  15. Outside-out "sniffer-patch" clamp technique for in situ measures of neurotransmitter release.

    Science.gov (United States)

    Muller-Chrétien, Emilie

    2014-01-01

    The mechanism underlying neurotransmitter release is a critical research domain for the understanding of neuronal network function; however, few techniques are available for the direct detection and measurement of neurotransmitter release. To date, the sniffer-patch clamp technique is mainly used to investigate these mechanisms from individual cultured cells. In this study, we propose to adapt the sniffer-patch clamp technique to in situ detection of neurosecretion. Using outside-out patches from donor cells as specific biosensors plunged in acute cerebral slices, this technique allows for proper detection and quantification of neurotransmitter release at the level of the neuronal network.

  16. MRPC-PET: A new technique for high precision time and position measurements

    International Nuclear Information System (INIS)

    Doroud, K.; Hatzifotiadou, D.; Li, S.; Williams, M.C.S.; Zichichi, A.; Zuyeuski, R.

    2011-01-01

    The purpose of this paper is to consider a new technology for medical diagnosis: the MRPC-PET. This technology allows excellent time resolution together with 2-D position information thus providing a fundamental step in this field. The principle of this method is based on the Multigap Resistive Plate Chamber (MRPC) capable of high precision time measurements. We have previously found that the route to precise timing is differential readout (this requires matching anode and cathode strips); thus crossed strip readout schemes traditionally used for 2-D readout cannot be exploited. In this paper we consider the time difference from the two ends of the strip to provide a high precision measurement along the strip; the average time gives precise timing. The MRPC-PET thus provides a basic step in the field of medical technology: excellent time resolution together with 2-D position measurement.

  17. A Technique for Real-Time Ionospheric Ranging Error Correction Based On Radar Dual-Frequency Detection

    Science.gov (United States)

    Lyu, Jiang-Tao; Zhou, Chen

    2017-12-01

    Ionospheric refraction is one of the principal error sources for limiting the accuracy of radar systems for space target detection. High-accuracy measurement of the ionospheric electron density along the propagation path of radar wave is the most important procedure for the ionospheric refraction correction. Traditionally, the ionospheric model and the ionospheric detection instruments, like ionosonde or GPS receivers, are employed for obtaining the electron density. However, both methods are not capable of satisfying the requirements of correction accuracy for the advanced space target radar system. In this study, we propose a novel technique for ionospheric refraction correction based on radar dual-frequency detection. Radar target range measurements at two adjacent frequencies are utilized for calculating the electron density integral exactly along the propagation path of the radar wave, which can generate accurate ionospheric range correction. The implementation of radar dual-frequency detection is validated by a P band radar located in midlatitude China. The experimental results present that the accuracy of this novel technique is more accurate than the traditional ionospheric model correction. The technique proposed in this study is very promising for the high-accuracy radar detection and tracking of objects in geospace.

  18. Comparison between traditional laboratory tests, permeability measurements and CT-based fluid flow modelling for cultural heritage applications

    Energy Technology Data Exchange (ETDEWEB)

    De Boever, Wesley, E-mail: Wesley.deboever@ugent.be [UGCT/PProGRess, Dept. of Geology, Ghent University, Krijgslaan 281, 9000 Ghent (Belgium); Bultreys, Tom; Derluyn, Hannelore [UGCT/PProGRess, Dept. of Geology, Ghent University, Krijgslaan 281, 9000 Ghent (Belgium); Van Hoorebeke, Luc [UGCT/Radiation Physics, Dept. of Physics & Astronomy, Ghent University, Proeftuinstraat 86, 9000 Ghent (Belgium); Cnudde, Veerle [UGCT/PProGRess, Dept. of Geology, Ghent University, Krijgslaan 281, 9000 Ghent (Belgium)

    2016-06-01

    In this paper, we examine the possibility to use on-site permeability measurements for cultural heritage applications as an alternative for traditional laboratory tests such as determination of the capillary absorption coefficient. These on-site measurements, performed with a portable air permeameter, were correlated with the pore network properties of eight sandstones and one granular limestone that are discussed in this paper. The network properties of the 9 materials tested in this study were obtained from micro-computed tomography (μCT) and compared to measurements and calculations of permeability and the capillary absorption rate of the stones under investigation, in order to find the correlation between pore network characteristics and fluid management characteristics of these sandstones. Results show a good correlation between capillary absorption, permeability and network properties, opening the possibility of using on-site permeability measurements as a standard method in cultural heritage applications. - Highlights: • Measurements of capillary absorption are compared to in-situ permeability. • We obtain pore size distribution and connectivity by using micro-CT. • These properties explain correlation between permeability and capillarity. • Correlation between both methods is good to excellent. • Permeability measurements could be a good alternative to capillarity measurement.

  19. The immediate effect of individual manipulation techniques on pulmonary function measures in persons with chronic obstructive pulmonary disease.

    Science.gov (United States)

    Noll, Donald R; Johnson, Jane C; Baer, Robert W; Snider, Eric J

    2009-10-08

    The use of manipulation has long been advocated in the treatment of chronic obstructive pulmonary disease (COPD), but few randomized controlled clinical trials have measured the effect of manipulation on pulmonary function. In addition, the effects of individual manipulative techniques on the pulmonary system are poorly understood. Therefore, the purpose of this study was to determine the immediate effects of four osteopathic techniques on pulmonary function measures in persons with COPD relative to a minimal-touch control protocol. Persons with COPD aged 50 and over were recruited for the study. Subjects received five, single-technique treatment sessions: minimal-touch control, thoracic lymphatic pump (TLP) with activation, TLP without activation, rib raising, and myofascial release. There was a 4-week washout period between sessions. Protocols were given in random order until all five techniques had been administered. Pulmonary function measures were obtained at baseline and 30-minutes posttreatment. For the actual pulmonary function measures and percent predicted values, Wilcoxon signed rank tests were used to test within-technique changes from baseline. For the percent change from baseline, Friedman tests were used to test for between-technique differences. Twenty-five subjects were enrolled in the study. All four tested osteopathic techniques were associated with adverse posttreatment changes in pulmonary function measures; however, different techniques changed different measures. TLP with activation increased posttreatment residual volume compared to baseline, while TLP without activation did not. Side effects were mild, mostly posttreatment chest wall soreness. Surprisingly, the majority of subjects believed they could breathe better after receiving osteopathic manipulation. In persons with COPD, TLP with activation, TLP without activation, rib raising, and myofascial release mildly worsened pulmonary function measures immediately posttreatment relative to

  20. Mechanical seal monitoring technique by acoustic emission measurements

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Tadashi; Fujita, Yoshihiro; Kawaguchi, Kazunori; Saito, Kazuhiro; Yokota, Setsuo; Hisada, Yasuhide; Masahiro, Komatsu

    1987-09-20

    This report describes a technique for mechanical seal monitoring through acoustic emission (AE) measurement. The equipment consists of an AE sensor, preamplifier, multiplexer, main amplifier, effective value transducer and computer system. When the sealed liquid pressure undergoes a large change, the seal surface configuration is monitored and evaluated accurately through AE measurement. If the mechanical seal surface id damaged or worn, the AE level is kept high or continues to fluctuate largely for a rather long period. When leak occurs, the AE value shows great fluctuations either at extremely low levels or at high levels. The former trend is considered to result from a decrease in solid contact due to an excessive amount of liquid film being formed at the seal surface during leak. In the latter case, the leak is attributed to severe damage to the seal surface. (18 figs, 1 tab, 5 photos, 3 refs)

  1. Identification of marine traditional Chinese medicine dried seahorses in the traditional Chinese medicine market using DNA barcoding.

    Science.gov (United States)

    Hou, Feixia; Wen, Longlian; Peng, Cheng; Guo, Jinlin

    2018-01-01

    Seahorse documented in Chinese pharmacopeia possess important medicinal efficacy and are used as an ingredient in traditional Chinese medicines. The growing international trade threatens the species. DNA barcoding holds a great application potentiality in wildlife conservation and might prevent the illegal trade of threatened species. The COI gene was used to identify seahorse, and nine Hippocampus species were found in the three large traditional Chinese medicines markets of China. All inter-specific genetic variations were larger than 2%. Mean genetic distances between species were 17-fold larger than those within the species. Phylogenetic tree showed that each species clustered in the appropriate branch. All results demonstrated that COI-based barcoding technique could be used to identify seahorse species and played a major role in monitoring the seahorse trade.

  2. A technique system for the measurement, reconstruction and character extraction of rice plant architecture.

    Directory of Open Access Journals (Sweden)

    Xumeng Li

    Full Text Available This study developed a technique system for the measurement, reconstruction, and trait extraction of rice canopy architectures, which have challenged functional-structural plant modeling for decades and have become the foundation of the design of ideo-plant architectures. The system uses the location-separation-measurement method (LSMM for the collection of data on the canopy architecture and the analytic geometry method for the reconstruction and visualization of the three-dimensional (3D digital architecture of the rice plant. It also uses the virtual clipping method for extracting the key traits of the canopy architecture such as the leaf area, inclination, and azimuth distribution in spatial coordinates. To establish the technique system, we developed (i simple tools to measure the spatial position of the stem axis and azimuth of the leaf midrib and to capture images of tillers and leaves; (ii computer software programs for extracting data on stem diameter, leaf nodes, and leaf midrib curves from the tiller images and data on leaf length, width, and shape from the leaf images; (iii a database of digital architectures that stores the measured data and facilitates the reconstruction of the 3D visual architecture and the extraction of architectural traits; and (iv computation algorithms for virtual clipping to stratify the rice canopy, to extend the stratified surface from the horizontal plane to a general curved surface (including a cylindrical surface, and to implement in silico. Each component of the technique system was quantitatively validated and visually compared to images, and the sensitivity of the virtual clipping algorithms was analyzed. This technique is inexpensive and accurate and provides high throughput for the measurement, reconstruction, and trait extraction of rice canopy architectures. The technique provides a more practical method of data collection to serve functional-structural plant models of rice and for the

  3. Measurement techniques for in situ stresses around underground constructions in a deep clay formation

    Directory of Open Access Journals (Sweden)

    Li X.L.

    2010-06-01

    Full Text Available Disposal in deep underground geological formations is internationally recognized as the most viable option for the long-term management of high-level radioactive waste. In Belgium, the Boom clay formation is extensively studied in this context, in particular at the 225 m deep HADES Underground Research Facility in Mol. A cost-effective design of deep underground structures requires an accurate assessment of the in situ stresses; a good estimation of these stresses is also essential when interpreting in situ experiments regarding the hydro-mechanical behaviour of the host formation. Different measurement techniques are available to provide data on the stress evolution and other mechanical properties of the geological formation. The measurement can be direct (measurement of total pressure, or it can be an indirect technique, deriving the stress from related quantities such as strain (changes in structural members. Most total stress measurements are performed through permanently installed sensors; also once-only measurements are performed through specific methods (e.g. pressuremeter. Direct measurement of the stress state is challenging due to the complex mechanical behaviour of the clay, and the fact that the sensor installation inevitably disturbs the original stress field. This paper describes ways to deal with these problems and presents the results obtained using different techniques at HADES.

  4. Recent improvements in PIE-techniques at the IFE hot-laboratory

    International Nuclear Information System (INIS)

    Jenssen, Haakon Kristian

    1999-01-01

    The PIE-techniques at the IFE nuclear fuel section are continuously improved through upgrading of equipment and methods, e.g. image handling techniques and components utilised in data acquisition and editing techniques. To improve the quality or spatial resolution of neutron radiographs the normal technique was complemented with another method. The dysprosium foil/X-ray film technique is now supplemented with a track-etch recorder consisting of a cellulose nitrate film. For further examination the cellulose nitrate film can be digitised to allow electronic image treatment. Promising results were obtained with this technique on neutron radiographs, namely higher spatial resolution compared to the normal technique, high contrast and sharp neutron radiography images. The traditional one-axial profilometry of fuel rods were modified so that diameter/bow measurements are possible at several angular orientations during one acquisition sequence. This extension is very useful in several ways, for instance the built-in data symmetry of the method is used to check the correctness of the measurement results. Diameter and bow measurements give in addition detailed and complete information of canning irregularities and fuel rod profiles. PIE data are collected and compiled in an image file. Inspection and examination of the file information is possible through an ideal user-interface, i.e. Adobe photoshop software with navigator possibilities. An example incorporating PIE data acquired from a fuel rod exposed in a loss of coolant experiment is utilised for illustration of the user-interface and some of its possibilities (author) (ml)

  5. The Spear: The Main Weapon in Iranian Martial Tradition

    Directory of Open Access Journals (Sweden)

    Manouchehr Moshtagh Khorasani

    2012-07-01

    Full Text Available In martial tradition, spears and lances have always played a very important role as main weapons on the battlefield, as exemplified through Iranian military history. Its reach and cheap production were important factors for establishing formations of soldiers equipped with spears and lances. Additionally, the combat techniques of spears and lances were relatively easy and one could learn the techniques of spearfighting and lancefighting much easier than other weapons, such as swords. The first part of the article describes some types of spears and lances that were used in the Islamic period of Iran. Then the method of carrying a spear/lance is analyzed and additionally some offensive techniques, feinting techniques, attacking techniques to the animal carrying the opponent, and defensive techniques using spears/lances are described as documented by Persian manuscripts.

  6. Integrating Traditional Bullying and Cyberbullying: Challenges of Definition and Measurement in Adolescents -- A Review

    Science.gov (United States)

    Thomas, Hannah J.; Connor, Jason P.; Scott, James G.

    2015-01-01

    The need for an integrated approach to studying bullying behaviors, both traditional and cyber, in adolescents is increasingly evident. The definitional criteria of bullying are well established in the traditional bullying literature and include (i) intention, (ii) repetition, and (iii) power imbalance. There is emerging evidence that these same…

  7. Measuring techniques for the characterisation of 137Cs contaminated river banks, Slovakia

    International Nuclear Information System (INIS)

    Slavik, O.; Moravek, J.

    2000-01-01

    In 1990, 137 Cs contaminated areas were discovered along 19 km of the banks of the rivers receiving discharged waste waters from the Bohunice NPP. The contamination was the result of uncontrolled releases of drainage water from the radioactive waste treatment unit and two accidents on the CO 2 cooled and heavy water moderated NPP-A1 unit in 1976 and 1977. In total, more than 67.000 m 2 of bank surfaces (the lower and middle parts of their slopes) have been found to be contaminated with 137 Cs at levels exceeding 1 kBq/kg of soil. This paper describes the planning for restoration of these river banks with emphasis on site characterization techniques used for these purposes. The general strategy and application of monitoring techniques for the purposes of characterisation of contaminated river banks is the main topic of the work performed in the context of the IAEA CRP on 'Site Characterisation Techniques for Environmental Restoration'. First results in developing new and more sophisticated measuring techniques, needed for the characterization of discontinuous and spot-contamination found on parts of the banks are given. The technique described is based on a dose rate measurement approach, using ratio of two detector readings at two different distances above ground and Monte-Carlo simulations of the plastic scintillation detector responses. The method will also be useful, for the final, post-remediation survey of residual spots of 137 Cs contamination. (author)

  8. Massage Therapy in Iranian Traditional Medicine

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Jaladat

    2012-10-01

    Full Text Available Background and Aim: Massage training and how the body is influenced by massage are common issues which are seriously under study and discussion in Iranian traditional medicine. Iranian physicians considered motion and massage as major principles of health maintenance.In this study, we examined the available literature of traditional medicine to evaluate location, purpose and use of massage therapy in Iranian medicine in comparison with other popular conventional styles.The aim of Iranian massage is to regulate the core body temperature and aid to eliminate the waste products from the body. This type of massage is divided into five categories including solid, soft, moderate, great and aggressive, based on the intensity, speed, duration and techniques of massage.Iranian physicians proposed general body massage or massage of a particular area based on subjective complaints. They recommended specific massages in particular groups including children, pregnant women, the elderly and athletes. In some cases, the effects of these recommendations have been studied in clinical trials.Conclusion: It seems that the major difference between Iranian massage and other styles of massage is special attention of Iranian massage to the individual circumstances, and the cause of the problem rather than technique of the massage.

  9. Power quality research techniques: advantages and disadvantages

    International Nuclear Information System (INIS)

    Gil Montoya, Francisco; Manzano Agugliaro, Francisco; Gomez Lopez, Julio; Sanchez Alguacil, Pedro

    2012-01-01

    Nowadays, power quality (PQ) plays a very important role in power systems. So that is why it is very important to use suitable tools allowing a precise detection of anomalies and perturbations in power systems. Given traditional analysis techniques, such as Fourier Transform, today new tools are being developed based on domain transformation, such as Wavelet Transform (WT) or S-Transform (ST), along with Artificial Intelligence (AI) techniques such as Fuzzy Logic (FL) or Artificial Neural Networks (ANN). In this paper, new algorithm and mathematic techniques are reviewed and discussed, and also compared with traditional techniques, revealing the precision and superiority achieved with these new techniques. ST and WT is detailed, basically, as a tool with great scope and future in power quality analysis because of its precision, noise immunity and its contribution with quality information about PQ.

  10. A safeguards verification technique for solution homogeneity and volume measurements in process tanks

    International Nuclear Information System (INIS)

    Suda, S.; Franssen, F.

    1987-01-01

    A safeguards verification technique is being developed for determining whether process-liquid homogeneity has been achieved in process tanks and for authenticating volume-measurement algorithms involving temperature corrections. It is proposed that, in new designs for bulk-handling plants employing automated process lines, bubbler probes and thermocouples be installed at several heights in key accountability tanks. High-accuracy measurements of density using an electromanometer can now be made which match or even exceed analytical-laboratory accuracies. Together with regional determination of tank temperatures, these measurements provide density, liquid-column weight and temperature gradients over the fill range of the tank that can be used to ascertain when the tank solution has reached equilibrium. Temperature-correction algorithms can be authenticated by comparing the volumes obtained from the several bubbler-probe liquid-height measurements, each based on different amounts of liquid above and below the probe. The verification technique is based on the automated electromanometer system developed by Brookhaven National Laboratory (BNL). The IAEA has recently approved the purchase of a stainless-steel tank equipped with multiple bubbler and thermocouple probes for installation in its Bulk Calibration Laboratory at IAEA Headquarters, Vienna. The verification technique is scheduled for preliminary trials in late 1987

  11. Passive directional discrimination in laser-Doppler anemometry by the two-wavelength quadrature homodyne technique.

    Science.gov (United States)

    Büttner, Lars; Czarske, Jürgen

    2003-07-01

    We report a method for passive optical directional discrimination in laser-Doppler anemometers. For this purpose frequency-shift elements such as acousto-optic modulators, which are bulky and difficult to align during assembly, have traditionally been employed. We propose to use a quadrature homodyne technique to achieve directional discrimination of the fluid flow without any frequency-shift elements. It is based on the employment of two laser wavelengths, which generate two interference fringe systems with a phase shift of a quarter of the common fringe spacing. Measurement signal pairs with a direction-dependent phase shift of +/- pi/2 are generated. As a robust signal-processing technique, the cross-correlation technique is used. The principles of quadrature homodyne laser-Doppler anemometry are investigated. A setup that provides a constant phase shift of pi/2 throughout the entire measurement volume was achieved with both single-mode and multimode radiation. The directional discrimination was successfully verified with wind tunnel measurements. The complete passive technique offers the potential of building miniaturized measurement heads that can be integrated, e.g., into wind tunnel models.

  12. Assessment of respondent acceptability of preference measures: discriminatory power of graphic positioning scale versus traditional scaling measures.

    Science.gov (United States)

    Franic, Duska M; Pathak, Dev S

    2003-01-01

    The objective of this study was to compare discriminatory power of two different measures-graphic positioning scale (GPS) versus traditional scale (TS)-in assessing respondent acceptability of three preference measures: visual analog scale (VAS), standard gamble (SG), and willingness to pay (WTP). Two face-to-face interviews were conducted at least 1 week apart in a convenience sample of women aged 22 to 50 years with no history of breast cancer or cancer requiring chemotherapy. Study participation required completion of two surveys: one evaluating health preferences for an acute condition (chemotherapy-induced nausea and vomiting) and one evaluating a chronic condition (breast cancer). Data were collected from March 2000 to June 2000 at Ohio State University. Respondents were randomized to either GPS or TS surveys. Data analysis was a two-step process. First, a four-way multivariate repeated-measures analysis of variance (MANOVA) was conducted to assess respondent acceptability of three-preference metrics-VAS, SG, and WTP-in health-care decision making. Each of the four dependent variables, difficulty, clarity, reasonableness, and comfort in use in decision making, was measured on 9-point Likert scale. Second, a mixed design univariate analysis of variance (ANOVA) was performed for each dependent variable to optimize MANOVA analysis. Univariate ANOVAs, 2 x (2 x 3), were composed of three independent variables: assessment (GPS/TS), condition (acute and chronic), and preferences (VAS, SG, WTP). Of 126 respondents, 119 were usable and complete. MANOVA results showed (P <.05) for two main effects, condition (F4,114 = 6.375) and preferences (F8,110 = 9.290), and two significant interactions, condition x assessment (F4,114 = 3.421) and condition x preferences (F8,110 = 2.087). GPS has higher discriminatory power than TS in assessing respondent attitudes toward health preference measures. Results showed that respondents had more difficulty and less comfort when making

  13. Towards convective heat transfer enhancement: surface modification, characterization and measurement techniques

    NARCIS (Netherlands)

    Taha, T.J.; Thakur, D.B.; van der Meer, Theodorus H.

    2012-01-01

    In this work, heat transfer surface modification and heat transfer measurement technique is developed. Heat transfer investigation was aimed to study the effect of carbon nano fibers (extremely high thermal conductive material) on the enhancement level in heat transfer. Synthesis of these carbon

  14. Dynamic-speckle profilometer for online measurements of coating thickness

    Energy Technology Data Exchange (ETDEWEB)

    Kamshilin, A A [Laboratory of Optical Sensor Technology, Department of Physics, University of Kuopio, PO Box 1627, FIN-70211 Kuopio (Finland); Semenov, D V [Laboratory of Optical Sensor Technology, Department of Physics, University of Kuopio, PO Box 1627, FIN-70211 Kuopio (Finland); Nippolainen, E [Laboratory of Optical Sensor Technology, Department of Physics, University of Kuopio, PO Box 1627, FIN-70211 Kuopio (Finland); Miridonov, S [Optics Department, CICESE, Carr. Tijuana-Ensenada km 107, C.P. 22860, A.P. 360, Ensenada, B.C. (Mexico)

    2007-10-15

    Online control of thickness of as-deposited coatings is of great importance because it directly affects the quality of protective coatings. We present a novel approach that enables online, real-time and non-contact measurements thickness of thermally sprayed coatings. The proposed technique uses dynamic speckles generated by rapidly deflecting laser beam. Within 10 ms the system can scan 500 times a small area of the deposited layer thus resulting in measurement accuracy of 5 microns irrespectively of the layer roughness. In comparison with traditional optical triangulation technique of distance measurements, our system has following advantages: (i) much simpler optical scheme that includes conventional photodiode to measure the scattered light, (ii) much simpler electronics for real-time data processing, (iii) much higher speed of measurements.

  15. Dynamic-speckle profilometer for online measurements of coating thickness

    International Nuclear Information System (INIS)

    Kamshilin, A A; Semenov, D V; Nippolainen, E; Miridonov, S

    2007-01-01

    Online control of thickness of as-deposited coatings is of great importance because it directly affects the quality of protective coatings. We present a novel approach that enables online, real-time and non-contact measurements thickness of thermally sprayed coatings. The proposed technique uses dynamic speckles generated by rapidly deflecting laser beam. Within 10 ms the system can scan 500 times a small area of the deposited layer thus resulting in measurement accuracy of 5 microns irrespectively of the layer roughness. In comparison with traditional optical triangulation technique of distance measurements, our system has following advantages: (i) much simpler optical scheme that includes conventional photodiode to measure the scattered light, (ii) much simpler electronics for real-time data processing, (iii) much higher speed of measurements

  16. Adjustments of microwave-based measurements on coal moisture using natural radioactivity techniques

    Energy Technology Data Exchange (ETDEWEB)

    Prieto-Fernandez, I.; Luengo-Garcia, J.C.; Alonso-Hidalgo, M.; Folgueras-Diaz, B. [University of Oviedo, Gijon (Spain)

    2006-01-07

    The use of nonconventional on-line measurements of moisture and ash content in coal is presented. The background research is briefly reviewed. The possibilities of adjusting microwave-based moisture measurements using natural radioactive techniques, and vice versa, are proposed. The results obtained from the simultaneous analysis of moisture and ash content as well as the correlation improvements are shown.

  17. Initiatives: Nigeria. Traditional healers and PPFN in wedlock.

    Science.gov (United States)

    Adejo, A A

    1996-04-01

    The Planned Parenthood Federation of Nigeria (PPFN) runs a program to integrate modern contraception into the practice of traditional medicine. Under the project, traditional healers, largely male, are trained on the ideals of nonprescriptive contraceptives such as condoms, the oral contraceptive pill, and foaming tablets, and how to offer such services to their clients. They participate in a two-week, highly participatory training course which confers a comprehensive introduction to basic and integrated reproductive health care service delivery, simple human anatomy and physiology, and human reproduction. The benefits of modern contraception are reviewed along with community mobilization and counseling. Simple communication techniques such as songs, drama, and role play are discussed. Information on maternal and child health and child survival, basic hygiene, nutrition, and AIDS is also incorporated into the course. 136 traditional healers have thus far been trained in three local government areas (LGAs) of Lagos State and 150 in six other LGAs in Benue State. The project has resulted in strong referral linkages between traditional healers, modern practitioners, and PPFN.

  18. Digitally controlled measurement of sonic elastic moduli and internal friction by phase analysis

    International Nuclear Information System (INIS)

    O'Brien, M.H.; Hunter, O. Jr.; Rasmussen, M.D.; Skank, H.D.

    1983-01-01

    An automated system is described for measuring internal friction and elastic moduli using sonic resonance techniques. This mirocomputer-controlled device does phase angle analysis in addition to traditional decay and peak-width internal friction measurement. The apparatus may be programmed to make measurements at any sequence of temperatures between room temperature and 1600 0 C

  19. A Comparative Analysis of Charter Schools and Traditional Public Schools

    Science.gov (United States)

    Smith, Jodi Renee Abbott

    2014-01-01

    The focus of this descriptive research study was to compare charter and traditional public schools on the academic knowledge of fifth grade students as measured by Arizona's Instrument to Measure Standards (AIMS) in a suburb of a large southwestern city. This analysis also compared charter and traditional public schools on AYP status. It was…

  20. Innovative High-Accuracy Lidar Bathymetric Technique for the Frequent Measurement of River Systems

    Science.gov (United States)

    Gisler, A.; Crowley, G.; Thayer, J. P.; Thompson, G. S.; Barton-Grimley, R. A.

    2015-12-01

    Lidar (light detection and ranging) provides absolute depth and topographic mapping capability compared to other remote sensing methods, which is useful for mapping rapidly changing environments such as riverine systems. Effectiveness of current lidar bathymetric systems is limited by the difficulty in unambiguously identifying backscattered lidar signals from the water surface versus the bottom, limiting their depth resolution to 0.3-0.5 m. Additionally these are large, bulky systems that are constrained to expensive aircraft-mounted platforms and use waveform-processing techniques requiring substantial computation time. These restrictions are prohibitive for many potential users. A novel lidar device has been developed that allows for non-contact measurements of water depth down to 1 cm with an accuracy and precision of shallow to deep water allowing for shoreline charting, measuring water volume, mapping bottom topology, and identifying submerged objects. The scalability of the technique opens up the ability for handheld or UAS-mounted lidar bathymetric systems, which provides for potential applications currently unavailable to the community. The high laser pulse repetition rate allows for very fine horizontal resolution while the photon-counting technique permits real-time depth measurement and object detection. The enhanced measurement capability, portability, scalability, and relatively low-cost creates the opportunity to perform frequent high-accuracy monitoring and measuring of aquatic environments which is crucial for understanding how rivers evolve over many timescales. Results from recent campaigns measuring water depth in flowing creeks and murky ponds will be presented which demonstrate that the method is not limited by rough water surfaces and can map underwater topology through moderately turbid water.

  1. Decoupling pipeline influences in soil resistivity measurements with finite element techniques

    Science.gov (United States)

    Deo, R. N.; Azoor, R. M.; Zhang, C.; Kodikara, J. K.

    2018-03-01

    Periodic inspection of pipeline conditions is an important asset management strategy conducted by water and sewer utilities for efficient and economical operations of their assets in field. The Level 1 pipeline condition assessment involving resistivity profiling along the pipeline right-of-way is a common technique for delineating pipe sections that might be installed in highly corrosive soil environment. However, the technique can suffer from significant perturbations arising from the buried pipe itself, resulting in errors in native soil characterisation. To address this problem, a finite element model was developed to investigate the degree to which pipes of different a) diameters, b) burial depths, and c) surface conditions (bare or coated) can influence in-situ soil resistivity measurements using Wenner methods. It was found that the greatest errors can arise when conducting measurements over a bare pipe with the array aligned parallel to the pipe. Depending upon the pipe surface conditions, in-situ resistivity measurements can either be underestimated or overestimated from true soil resistivities. Following results based on simulations and decoupling equations, a guiding framework for removing pipe influences in soil resistivity measurements were developed that can be easily used to perform corrections on measurements. The equations require simple a-prior information on the pipe diameter, burial depth, surface condition, and the array length and orientation used. Findings from this study have immediate application and is envisaged to be useful for critical civil infrastructure monitoring and assessment.

  2. Physical, physicochemical and nutritional characteristics of Bhoja chaul, a traditional ready-to-eat dry heat parboiled rice product processed by an improvised soaking technique.

    Science.gov (United States)

    Dutta, Himjyoti; Mahanta, Charu Lata; Singh, Vasudeva; Das, Barnali Baruah; Rahman, Narzu

    2016-01-15

    Bhoja chaul is a traditional whole rice product processed by the dry heat parboiling technique of low amylose/waxy paddy that is eaten after soaking in water and requires no cooking. The essential steps in Bhoja chaul making are soaking paddy in water, roasting with sand, drying and milling. In this study, the product was prepared from a low amylose variety and a waxy rice variety by an improvised laboratory scale technique. Bhoja chaul prepared in the laboratory by this technique was studied for physical, physicochemical, and textural properties. Improvised method shortened the processing time and gave a product with good textural characteristics. Shape of the rice kernels became bolder on processing. RVA studies and DSC endotherms suggested molecular damage and amylose-lipid complex formation by the linear B-chains of amylopectin, respectively. X-ray diffractography indicated formation of partial B-type pattern. Shifting of the crystalline region of the XRD curve towards lower values of Bragg's angle was attributed to the overall increase in inter-planar spacing of the crystalline lamellae. Resistant starch was negligible. Bhoja chaul may be useful for children and people with poor state of digestibility. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Modern techniques for studying biofilm-influenced corrosion

    International Nuclear Information System (INIS)

    Beech, I.B.

    1998-01-01

    In natural and made-made environments the presence of biofilms on surfaces of metals and their alloys influences electrochemistry at the biofilm/substratum interface, enhancing or inhibiting corrosion reactions. Due to the complexity of the biocorrosion phenomenon a range of techniques is commonly employed to study mechanisms involved. In addition to traditional methods of corrosion investigation such as electrochemical measurements and light and scanning electron microscopy observations coupled with energy dispersive X-ray analysis (EDXA) and X-ray diffraction (XRD). Modern techniques of surface science proved to be very useful in elucidating biofilm/metal interactions. Recent applications of Environmental Scanning Electron Microscopy (ESEM), Atomic Force Microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS) to biocorrosion studies allowed better understanding of the biologically influenced metal deterioration process. The scope and promise of these latter techniques will be discussed and their use illustrated on practical examples. (Author)

  4. Techniques de débitmétrie polyphasique non intrusive. Revue bibliographique Non Intrusive Multiphase Flow Measurement Techniques. Bibliographic Review

    Directory of Open Access Journals (Sweden)

    Lynch J.

    2006-11-01

    Full Text Available Cet article présente les différentes techniques de débitmétrie polyphasique non intrusive décrites dans la littérature du domaine public. Ces techniques sont considérées du point de vue de leur application dans le cadre de la production pétrolière sous-marine (mélange eau/huile/gaz. A partir d'une analyse des différentes méthodes physiques qui peuvent être utilisées, des perspectives d'avenir sont proposées. Several operations in the oil reservoir exploitation industry call for flowmeters capable of delivering information on the quantity and rate of flow of the different phases (gas, oil, water, solids . . . present in a pipeline. Amongst these are the estimation of remaining reserves and of well performance, control of production units such as multiphase pumping systems and fiscal monitoring in the case of pipeline networking. Existing methods, based on phase separation, require separate test lines and thus tend to be cumbersome, give only intermittent values of flow parameters and need to be calibrated due to the intrusive nature of the measurements. These drawbacks are seen to be all the more critical in subsea production where the ideal flowmeter would be compact, require little maintenance and supply precise real time data for network and multiphase pump control. In recent years flow measurement in two or more phase systems has received increasing attention both in laboratory studies and for applications in a variety of industries (for example : nuclear power production and food processing as well as of course oil production. We review here the many methods considered for non-intrusive flow metering with two or more components from the point of view of an industrial (in particular subsea oil production application. The situation is rendered delicate, in particular for density measurement, by the uncontrolled nature of the flow which may occur in any of several regimes with differing spatial distributions of the components

  5. Comparison of safety measures with a multicriteria decision aiding technique

    International Nuclear Information System (INIS)

    Lombard, J.

    1985-01-01

    Attributes such as political, social and psychological factors have to be taken into account for the decision-making process. Multiattribute decision-aiding techniques are used to cope with this multidimensionality of the risk management process. A simple example will be given to illustrate how such method can be helpful for the selection of proper safety measures in a rational way. (orig./HP) [de

  6. Accuracy of MRI technique in measuring tendon cross-sectional area

    DEFF Research Database (Denmark)

    Couppé, Christian; Svensson, R. B.; Elbrønd (Bibs), Vibeke Sødring

    2014-01-01

    , but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the patellar...... tendon CSA. Thereafter, the patellar tendon of the horse was completely dissected and embedded in an alginate cast. The CSA of the embedded tendon was measured directly by optical imaging of the cast impression. 1.5 tesla grey tendon CSA and 3 tesla grey tendon CSA were 16.5% and 13.2% lower than...... the mould tendon CSA, respectively. Also, 3 tesla tendon CSA, based on the red-green border on the National Institute of Health (NIH) colour scale, was lower than the mould tendon CSA by 2.8%. The typical error between examiners was below 2% for all the measured CSA. The typical error between examiners...

  7. SYSTEM CONTROL OF SMOKING PROCESS AND MEASURING BENZO[A]PYRENE IN TRADITIONAL PRODUCTION OF BOSNIAN DRY CURED HAM (BOSANSKI PRŠUT BY IMPLEMENTING HACCP SYSTEM

    Directory of Open Access Journals (Sweden)

    Almir Toroman

    2013-08-01

    Full Text Available As it is well known, traditional production of smoked meat products requires technological processes, which carry some food safety hazards (e.g. content of Benzo[a]pyrene. (B[a]P. “OMEGA COMERC Ltd.”, a member of the meat industry in Visoko region, has implemented food safety management system according to the recommendations from Codex Alimentarius CAC-RCP (9, recommended International Code of Practice - General Principles of Food Hygiene. By implementing HACCP system, the Company established adequate control measures in producing Bosnian dry cured ham (bosanski pršut on traditional way including the smoking process in the chambers. By doing this, they have created conditions to measure B[a]P content in the Bosnian dry cured ham and implement HACCP system without impairing traditional production and food safety of the final product.The aim of this study is to present the effect of the specific production process onto the meat smoking in order to preserve hygienic, nutritional and sensory values, and also to control B[a]P content in the final product.Key words: Bosnian dry cured ham, traditional production, smoking process, Benzo[a]pyrene, HACCP

  8. Hyperfine interactions measured by nuclear orientation technique

    International Nuclear Information System (INIS)

    Brenier, R.

    1982-01-01

    This report concerns the use of hyperfine interaction to magnetism measurements and to the determination of the nuclear structure of Terbium isotopes by the low temperature nuclear orientation technique. In the first part we show that the rhodium atom does not support any localized moment in the chromium matrix. The hyperfine magnetic field at the rhodium nuclear site follows the Overhauser distribution, and the external applied magnetic field supports a negative Knight shift of 16%. In the second part we consider the structure of neutron deficient Terbium isotopes. We introduce a coherent way of evaluation and elaborate a new nuclear thermometer. The magnetic moments allows to strike on the studied states configuration. The analysis of our results shows a decrease of the nuclear deformation for the lighter isotopes [fr

  9. Measurement of morphing wing deflection by a cross-coherence fiber optic interferometric technique

    Science.gov (United States)

    Tomić, Miloš C.; Djinović, Zoran V.; Scheerer, Michael; Petricevic, Slobodan J.

    2018-01-01

    A fiber-optic interferometric technique aimed at measuring the deflection of aircrafts’ morphing wings is presented. The wing deflection induces a strain in the sensing fiber optic coils that are firmly fixed onto the wing. A change of the phase angle of the light propagating through the fiber is measured by an ‘all-in-fiber’ Michelson interferometer based on a 3 × 3 fiber-optic coupler. Two light sources of different coherence lengths and wavelengths are simultaneously used to ensure a wide measurement range and high accuracy. A new technique for determination of the zero deflection point using the cross-correlation of the two interferograms is proposed. The experiments performed on a specimen made of a carbon-fiber-reinforced plastic honeycomb structure demonstrated a relative uncertainty morphing wing deflection.

  10. Safety of Traditional Arab Herbal Medicine

    Directory of Open Access Journals (Sweden)

    Bashar Saad

    2006-01-01

    Full Text Available Herbal remedies are widely used for the treatment and prevention of various diseases and often contain highly active pharmacological compounds. Many medicinal herbs and pharmaceutical drugs are therapeutic at one dose and toxic at another. Toxicity related to traditional medicines is becoming more widely recognized as these remedies become popular in the Mediterranean region as well as worldwide. Most reports concerning the toxic effects of herbal medicines are associated with hepatotoxicity although reports of other toxic effects including kidney, nervous system, blood, cardiovascular and dermatologic effects, mutagenicity and carcinogenicity have also been published in the medical literature. This article presents a systematic review on safety of traditional Arab medicine and the contribution of Arab scholars to toxicology. Use of modern cell biological, biochemical, in vitro and in vivo techniques for the evaluation of medicinal plants safety is also discussed.

  11. Uncertainties in assessing tillage erosion - How appropriate are our measuring techniques?

    Science.gov (United States)

    Fiener, P.; Wilken, F.; Aldana-Jague, E.; Deumlich, D.; Gómez, J. A.; Guzmán, G.; Hardy, R. A.; Quinton, J. N.; Sommer, M.; Van Oost, K.; Wexler, R.

    2018-03-01

    Tillage erosion on arable land is a very important process leading to a net downslope movement of soil and soil constitutes. Tillage erosion rates are commonly in the same order of magnitude as water erosion rates and can be even higher, especially under highly mechanized agricultural soil management. Despite its prevalence and magnitude, tillage erosion is still understudied compared to water erosion. The goal of this study was to bring together experts using different techniques to determine tillage erosion and use the different results to discuss and quantify uncertainties associated with tillage erosion measurements. The study was performed in northeastern Germany on a 10 m by 50 m plot with a mean slope of 8%. Tillage erosion was determined after two sequences of seven tillage operations. Two different micro-tracers (magnetic iron oxide mixed with soil and fluorescent sand) and one macro-tracer (passive radio-frequency identification transponders (RFIDs), size: 4 × 22 mm) were used to directly determine soil fluxes. Moreover, tillage induced changes in topography were measured for the entire plot with two different terrestrial laser scanners and an unmanned aerial system for structure from motion topography analysis. Based on these elevation differences, corresponding soil fluxes were calculated. The mean translocation distance of all techniques was 0.57 m per tillage pass, with a relatively wide range of mean soil translocation distances ranging from 0.39 to 0.72 m per pass. A benchmark technique could not be identified as all used techniques have individual error sources, which could not be quantified. However, the translocation distances of the macro-tracers used were consistently smaller than the translocation distances of the micro-tracers (mean difference = - 26 ± 12%), which questions the widely used assumption of non-selective soil transport via tillage operations. This study points out that tillage erosion measurements, carried out under almost

  12. Comparison of 210Pb level in Kuala Muda tsunami affected marine sediment core measured using two different techniques

    International Nuclear Information System (INIS)

    Yii Mei Wo; Zal Uyun Wan Mahmood; Jalal Sharib; Zaharudin Ahmad

    2010-01-01

    The most commonly used techniques of alpha and gamma spectrometry were compared to measure 210 Pb activity in marine sediment core. Alpha analytical technique measured the activity of 210 Pb from its in-grow grand-daughter 210 Po after a chemical separation by assuming that there is radioactive equilibrium between the two radionuclides. Meanwhile, gamma analysis technique allows direct measurement, non-destructive and no preliminary chemical separation. Through the comparison, it was found that both alpha and gamma analysis techniques were slightly different. Overall, the results from gamma analytical technique were higher than those from the alpha analytical techniques. Some logical argument had been discussed to explain this situation. In routine analysis, the analytical technique used should be chosen carefully based on advantages and disadvantages of the each technique and analysis requirements. Therefore, it is recommended to determine the exact needs and purpose of analysis and to know the sample history before deciding the appropriate analytical technique. (author)

  13. Inverse kinetics technique for reactor shutdown measurement: an experimental assessment. [AGR

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, T. A.; McDonald, D.

    1975-09-15

    It is proposed to use the Inverse Kinetics Technique to measure the subcritical reactivity as a function of time during the testing of the nitrogen injection systems on AGRs. A description is given of an experimental assessment of the technique by investigating known transients created by control rod movements on a small experimental reactor, (2m high, 1m radius). Spatial effects were observed close to the moving rods but otherwise derived reactivities were independent of detector position and agreed well with the existing calibrations. This prompted the suggestion that data from installed reactor instrumentation could be used to calibrate CAGR control rods.

  14. Rethinking traditional methods for measuring intellectual capital.

    Science.gov (United States)

    Corso, John A

    2007-01-01

    Historically, approaches to measuring intellectual capital have included both conventional accounting-based measures, such as variants of the market-to-book ratio, and more progressive measures, such as the measurement of intangible assets found in approaches such as the Balanced Scorecard and Human Resource Accounting. As greater emphasis is placed on intellectual capital and its various aspects in the continually growing service and knowledge economy, the use of assessment instruments to inventory the alignment, balance, and variety of intellectual capacities and metrics that assess the effectiveness of succession planning may represent new directions in which organizations can head in the measurement of this important construct.

  15. Assessing energy techniques and measures in residential buildings: a multidisciplinary perspective

    NARCIS (Netherlands)

    Entrop, Alexis Gerardus

    2013-01-01

    Many Energy Techniques and Measures (ETMs) are available to reduce the fossil energy use of residential buildings. However, the rate at which these ETMs are implemented is relatively low. Bram Entrop (1980) addresses, in this design-oriented research, the influence that ETMs have on the energy

  16. Applying traditional signal processing techniques to social media exploitation for situational understanding

    Science.gov (United States)

    Abdelzaher, Tarek; Roy, Heather; Wang, Shiguang; Giridhar, Prasanna; Al Amin, Md. Tanvir; Bowman, Elizabeth K.; Kolodny, Michael A.

    2016-05-01

    Signal processing techniques such as filtering, detection, estimation and frequency domain analysis have long been applied to extract information from noisy sensor data. This paper describes the exploitation of these signal processing techniques to extract information from social networks, such as Twitter and Instagram. Specifically, we view social networks as noisy sensors that report events in the physical world. We then present a data processing stack for detection, localization, tracking, and veracity analysis of reported events using social network data. We show using a controlled experiment that the behavior of social sources as information relays varies dramatically depending on context. In benign contexts, there is general agreement on events, whereas in conflict scenarios, a significant amount of collective filtering is introduced by conflicted groups, creating a large data distortion. We describe signal processing techniques that mitigate such distortion, resulting in meaningful approximations of actual ground truth, given noisy reported observations. Finally, we briefly present an implementation of the aforementioned social network data processing stack in a sensor network analysis toolkit, called Apollo. Experiences with Apollo show that our techniques are successful at identifying and tracking credible events in the physical world.

  17. Minimal interference beam size/profile measurement techniques applicable to the Collider

    International Nuclear Information System (INIS)

    Nexsen, W.; Dutt, S.; Kauffmann, S.; Lebedev, V.; Maschke, A.; Mokhov, N.; Richardson, R.; Tsyganov, E.; Zinchenko, A.

    1993-05-01

    The imaging of synchrotron radiation (SR) has been suggested as a technique for providing a continuous, non-interfering monitor of the beam profile in the Collider rings at the Superconducting Super Collider. A closer examination has raised questions concerning the applicability of SR imaging in this case because of the diffraction broadening of the image, the requirements for axial space and location in the lattice, and the complexity of the system. We have surveyed the known, alternative, minimal interference techniques for measuring beam size and have evaluated them for possible Collider usage. We conclude that of the approaches that appear feasible, all require at least some development for our usage and that the development of an electron beam probe offers the best promise. We recommend that flying wires be used for cross-checking and calibrating the electron beam probe diagnostic and for luminosity measurements when the highest accuracy is required, but flying wires should not be used as the primary diagnostic because of their limited lifetime

  18. Correlation techniques for the improvement of signal-to-noise ratio in measurements with stochastic processes

    CERN Document Server

    Reddy, V R; Reddy, T G; Reddy, P Y; Reddy, K R

    2003-01-01

    An AC modulation technique is described to convert stochastic signal variations into an amplitude variation and its retrieval through Fourier analysis. It is shown that this AC detection of signals of stochastic processes when processed through auto- and cross-correlation techniques improve the signal-to-noise ratio; the correlation techniques serve a similar purpose of frequency and phase filtering as that of phase-sensitive detection. A few model calculations applied to nuclear spectroscopy measurements such as Angular Correlations, Mossbauer spectroscopy and Pulse Height Analysis reveal considerable improvement in the sensitivity of signal detection. Experimental implementation of the technique is presented in terms of amplitude variations of harmonics representing the derivatives of normal spectra. Improved detection sensitivity to spectral variations is shown to be significant. These correlation techniques are general and can be made applicable to all the fields of particle counting where measurements ar...

  19. A New Technique for SET Pulse Width Measurement in Chains of Inverters Using Pulsed Laser Irradiation

    International Nuclear Information System (INIS)

    Ferlet-Cavrois, V.; Fel, N.; Gaillardin, M.; Baggio, J.; Girard, S.; Flament, O.; Paillet, P.; McMorrow, D.; Melinger, J. S.; Kobayashi, D.; Hirose, K.; Saito, H.; Pouget, V.; Essely, F.; Schwank, J. R.; Flores, R. S.; Dodd, P. E.; Shaneyfelt, M. R.

    2009-01-01

    A new technique is developed to measure precisely and accurately the width of propagating voltage transients induced by irradiation of inverter chains. The technique is based on measurement of the supply current in a detection inverter, and permits a direct determination of the transient width with a 50 GHz bandwidth. (authors)

  20. A technique for measuring oxygen saturation in biological tissues based on diffuse optical spectroscopy

    Science.gov (United States)

    Kleshnin, Mikhail; Orlova, Anna; Kirillin, Mikhail; Golubiatnikov, German; Turchin, Ilya

    2017-07-01

    A new approach to optical measuring blood oxygen saturation was developed and implemented. This technique is based on an original three-stage algorithm for reconstructing the relative concentration of biological chromophores (hemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the probing radiation source. The numerical experiments and approbation of the proposed technique on a biological phantom have shown the high reconstruction accuracy and the possibility of correct calculation of hemoglobin oxygenation in the presence of additive noise and calibration errors. The obtained results of animal studies have agreed with the previously published results of other research groups and demonstrated the possibility to apply the developed technique to monitor oxygen saturation in tumor tissue.

  1. Airflow measurement techniques applied to radon mitigation problems

    International Nuclear Information System (INIS)

    Harrje, D.T.; Gadsby, K.J.

    1989-01-01

    During the past decade a multitude of diagnostic procedures associated with the evaluation of air infiltration and air leakage sites have been developed. The spirit of international cooperation and exchange of ideas within the AIC-AIVC conferences has greatly facilitated the adoption and use of these measurement techniques in the countries participating in Annex V. But wide application of such diagnostic methods are not limited to air infiltration alone. The subject of this paper concerns the ways to evaluate and improve radon reduction in buildings using diagnostic methods directly related to developments familiar to the AIVC. Radon problems are certainly not unique to the United States, and the methods described here have to a degree been applied by researchers of other countries faced with similar problems. The radon problem involves more than a harmful pollutant of the living spaces of our buildings -- it also involves energy to operate radon removal equipment and the loss of interior conditioned air as a direct result. The techniques used for air infiltration evaluation will be shown to be very useful in dealing with the radon mitigation challenge. 10 refs., 7 figs., 1 tab

  2. New test structures and techniques for measurement of mechanical properties of MEMS materials

    Science.gov (United States)

    Sharpe, William N., Jr.; Yuan, Bin; Vaidyanathan, Ranji; Edwards, Richard L.

    1996-09-01

    This paper presents techniques and procedures for addressing the three major problems of mechanical testing of the thin films used in surface micromachined microelectromechanical systems--specimen handling, friction, and strain measurement. The polysilicon tensile specimens are fabricated with two supporting side strips on silicon wafers at the Microelectronic Center of North Carolina. The tensile specimen is released by etching away the wafer, and the two support strips are cut after the specimen is glued in the test machine. Friction is reduced by a linear air bearing in the load train, and strain is measured with a noncontacting technique based on laser interferometry between two gold lines on the tensile specimen. The Young's modulus of polysilicon is 170 +/- 7 GPa and the strength is 1.21 +/- 0.16 GPa from a series of 29 tests. preliminary measurements have been made of Poisson's ratio and the fatigue behavior, and an attempt is underway to measure the fracture toughness.

  3. Understanding Notional Machines through Traditional Teaching with Conceptual Contraposition and Program Memory Tracing

    Directory of Open Access Journals (Sweden)

    Jeisson Hidalgo-Céspedes

    2016-08-01

    Full Text Available A correct understanding about how computers run code is mandatory in order to effectively learn to program. Lectures have historically been used in programming courses to teach how computers execute code, and students are assessed through traditional evaluation methods, such as exams. Constructivism learning theory objects to students’ passiveness during lessons, and traditional quantitative methods for evaluating a complex cognitive process such as understanding. Constructivism proposes complimentary techniques, such as conceptual contraposition and colloquies. We enriched lectures of a “Programming II” (CS2 course combining conceptual contraposition with program memory tracing, then we evaluated students’ understanding of programming concepts through colloquies. Results revealed that these techniques applied to the lecture are insufficient to help students develop satisfactory mental models of the C++ notional machine, and colloquies behaved as the most comprehensive traditional evaluations conducted in the course.

  4. Reliable cost effective technique for in situ ground stress measurements in deep gold mines.

    CSIR Research Space (South Africa)

    Stacey, TR

    1995-07-01

    Full Text Available on these requirements, an in situ stress measurement technique which will be practically applicable in the deep gold mines, has been developed conceptually. Referring to the figure on the following page, this method involves: • a borehole-based system, using... level mines have not been developed. 2 This is some of the background to the present SIMRAC research project, the title ofwhich is “Reliable cost effective technique for in-situ ground stress measurements in deep gold mines”. A copy of the research...

  5. Experimental technique to measure thoron generation rate of building material samples using RAD7 detector

    International Nuclear Information System (INIS)

    Csige, I.; Szabó, Zs.; Szabó, Cs.

    2013-01-01

    Thoron ( 220 Rn) is the second most abundant radon isotope in our living environment. In some dwellings it is present in significant amount which calls for its identification and remediation. Indoor thoron originates mainly from building materials. In this work we have developed and tested an experimental technique to measure thoron generation rate in building material samples using RAD7 radon-thoron detector. The mathematical model of the measurement technique provides the thoron concentration response of RAD7 as a function of the sample thickness. For experimental validation of the technique an adobe building material sample was selected for measuring the thoron concentration at nineteen different sample thicknesses. Fitting the parameters of the model to the measurement results, both the generation rate and the diffusion length of thoron was estimated. We have also determined the optimal sample thickness for estimating the thoron generation rate from a single measurement. -- Highlights: • RAD7 is used for the determination of thoron generation rate (emanation). • The described model takes into account the thoron decay and attenuation. • The model describes well the experimental results. • A single point measurement method is offered at a determined sample thickness

  6. Static telescope aberration measurement using lucky imaging techniques

    Science.gov (United States)

    López-Marrero, Marcos; Rodríguez-Ramos, Luis Fernando; Marichal-Hernández, José Gil; Rodríguez-Ramos, José Manuel

    2012-07-01

    A procedure has been developed to compute static aberrations once the telescope PSF has been measured with the lucky imaging technique, using a nearby star close to the object of interest as the point source to probe the optical system. This PSF is iteratively turned into a phase map at the pupil using the Gerchberg-Saxton algorithm and then converted to the appropriate actuation information for a deformable mirror having low actuator number but large stroke capability. The main advantage of this procedure is related with the capability of correcting static aberration at the specific pointing direction and without the need of a wavefront sensor.

  7. The low-frequency sound power measuring technique for an underwater source in a non-anechoic tank

    Science.gov (United States)

    Zhang, Yi-Ming; Tang, Rui; Li, Qi; Shang, Da-Jing

    2018-03-01

    In order to determine the radiated sound power of an underwater source below the Schroeder cut-off frequency in a non-anechoic tank, a low-frequency extension measuring technique is proposed. This technique is based on a unique relationship between the transmission characteristics of the enclosed field and those of the free field, which can be obtained as a correction term based on previous measurements of a known simple source. The radiated sound power of an unknown underwater source in the free field can thereby be obtained accurately from measurements in a non-anechoic tank. To verify the validity of the proposed technique, a mathematical model of the enclosed field is established using normal-mode theory, and the relationship between the transmission characteristics of the enclosed and free fields is obtained. The radiated sound power of an underwater transducer source is tested in a glass tank using the proposed low-frequency extension measuring technique. Compared with the free field, the radiated sound power level of the narrowband spectrum deviation is found to be less than 3 dB, and the 1/3 octave spectrum deviation is found to be less than 1 dB. The proposed testing technique can be used not only to extend the low-frequency applications of non-anechoic tanks, but also for measurement of radiated sound power from complicated sources in non-anechoic tanks.

  8. Measurement of scintillation decay curves by a single photon counting technique

    International Nuclear Information System (INIS)

    Noguchi, Tsutomu

    1978-01-01

    An improved apparatus suitable for the measurement of spectroscopic scintillation decay curves has been developed by combination of a single photon counting technique and a delayed coincidence method. The time resolution of the apparatus is improved up to 1.16 nsec (FWHM), which is obtained from the resolution function of the system for very weak Cherenkov light flashes. Systematic measurement of scintillation decay curves is made for liquid and crystal scintillators including PPO-toluene, PBD-xylene, PPO-POPOP-toluene, anthracene and stilbene. (auth.)

  9. Optical Measurement Techniques Innovations for Industry and the Life Sciences

    CERN Document Server

    Peiponen, Kai-Erik; Priezzhev, Alexander V

    2009-01-01

    Devoted to novel optical measurement techniques that are applied both in industry and life sciences, this book contributes a fresh perspective on the development of modern optical sensors. These sensors are often essential in detecting and controlling parameters that are important for both industrial and biomedical applications. The book provides easy access for beginners wishing to gain familiarity with the innovations of modern optics.

  10. Traditional processing of masau fruits (Ziziphus mauritiana) in Zimbabwe

    NARCIS (Netherlands)

    Nyanga, L.K.; Nout, M.J.R.; Gadaga, T.H.; Boekhout, T.; Zwietering, M.H.

    2008-01-01

    A survey of the traditional processing techniques of masau was conducted using a questionnaire and two focus group discussions in Mudzi, Mt. Darwin, and Muzarabani districts in Zimbabwe. Masau fruits form part of the family diet and generate additional income by selling at local markets. Surplus

  11. Nondestructive hall coefficient measurements using ACPD techniques

    Science.gov (United States)

    Velicheti, Dheeraj; Nagy, Peter B.; Hassan, Waled

    2018-04-01

    Hall coefficient measurements offer great opportunities as well as major challenges for nondestructive materials characterization. The Hall effect is produced by the magnetic Lorentz force acting on moving charge carriers in the presence of an applied magnetic field. The magnetic perturbation gives rise to a Hall current that is normal to the conduction current but does not directly perturb the electric potential distribution. Therefore, Hall coefficient measurements usually exploit the so-called transverse galvanomagnetic potential drop effect that arises when the Hall current is intercepted by the boundaries of the specimen and thereby produce a measurable potential drop. In contrast, no Hall potential is produced in a large plate in the presence of a uniform normal field at quasi-static low frequencies. In other words, conventional Hall coefficient measurements are inherently destructive since they require cutting the material under tests. This study investigated the feasibility of using alternating current potential drop (ACPD) techniques for nondestructive Hall coefficient measurements in plates. Specifically, the directional four-point square-electrode configuration is investigated with superimposed external magnetic field. Two methods are suggested to make Hall coefficient measurements in large plates without destructive machining. At low frequencies, constraining the bias magnetic field can replace constraining the dimensions of the specimen, which is inherently destructive. For example, when a cylindrical permanent magnet is used to provide the bias magnetic field, the peak Hall voltage is produced when the diameter of the magnet is equal to the diagonal of the square ACPD probe. Although this method is less effective than cutting the specimen to a finite size, the loss of sensitivity is less than one order of magnitude even at very low frequencies. In contrast, at sufficiently high inspection frequencies the magnetic field of the Hall current induces a

  12. Calibration technique for radiation measurements in vacuum ultraviolet - soft x-ray region

    International Nuclear Information System (INIS)

    Mizui, Jun-ichi

    1986-05-01

    This is a collection of the papers presented at the workshop on ''Calibration Technique for Radiation Measurements in Vacuum Ultraviolet - Soft X-ray Region'' held at the Institute of Plasma Physics, Nagoya University, on December 19 - 20, 1985, under the Collaborating Research Program at the Institute. The following topics were discussed at the workshop: the needs for the calibration of plasma diagnostic devices, present status of the calibration technique, use of the Synchrotron Orbit Radiations for radiometry, and others. (author)

  13. Reduced length of stay and convalescence in laparoscopic vs open sigmoid resection with traditional care

    DEFF Research Database (Denmark)

    Kaltoft, B; Gögenur, I; Rosenberg, J

    2011-01-01

    The effect of a laparoscopic technique without a multi-modal rehabilitation programme but with traditional postoperative care was studied in a blinded randomized trial regarding nursing time, hospital stay, pain, fatigue, need for sleep and return to normal daily activities.......The effect of a laparoscopic technique without a multi-modal rehabilitation programme but with traditional postoperative care was studied in a blinded randomized trial regarding nursing time, hospital stay, pain, fatigue, need for sleep and return to normal daily activities....

  14. Quick detection of traditional Chinese medicine ‘Atractylodis Macrocephalae Rhizoma’ pieces by surface-enhanced Raman spectroscopy

    Science.gov (United States)

    Huang, Hao; Shi, Hong; Feng, Shangyuan; Lin, Juqiang; Chen, Weiwei; Yu, Yun; Lin, Duo; Xu, Qian; Chen, Rong

    2013-01-01

    A surface-enhanced Raman spectroscopy (SERS) method was developed for the analysis of traditional Chinese medicine ‘Atractylodis Macrocephalae Rhizoma’ pieces (AMRP) for the first time with the aim to develop a quick method for traditional Chinese medicine detection. Both Raman spectra and SERS spectra were obtained from AMRP, and tentative assignments of the Raman bands in the measured spectra suggested that only a few weak Raman peaks could be observed in the regular Raman spectra, while primary Raman peaks at around 536, 555, 619, 648, 691, 733, 790, 958, 1004, 1031, 1112, 1244, 1324, 1395, 1469, 1574 and 1632 cm-1 could be observed in the SERS spectra, with the strongest signals at 619, 733, 958, 1324, 1395 and 1469 cm-1. This was due to a strong interaction between the silver colloids and the AMRP, which led to an extraordinary enhancement in the intensity of the Raman scattering in AMRP. This exploratory study suggests the SERS technique has great potential for providing a novel non-destructive method for effectively and accurately detecting traditional Chinese medicine without complicated separation and extraction.

  15. Measurement of histamine release from human lung tissue ex vivo by microdialysis technique

    DEFF Research Database (Denmark)

    Nissen, Dan; Petersen, Lars Jelstrup; Nolte, H

    1998-01-01

    OBJECTIVE AND DESIGN: Currently no method is available for measurement of mediator release from intact human lung. In this study, a microdialysis technique was used to measure histamine release from mast cells in human lung tissue ex vivo. MATERIAL: Microdialysis fibers of 216 microm were inserted...... responses were observed but data could be reproduced within individual donors. Monocyte chemoattractant protein-1, a potent basophil secretagogue, did not induce histamine release in lung tissue which indicated mast cells to be the histamine source. Substance P did not release histamine in the lung tissue....... CONCLUSIONS: The microdialysis technique allowed measurements of histamine release from mast cells in intact lung ex vivo. The method may prove useful since a number of experiments can be performed in a few hours in intact lung tissue without any dispersion or enzymatic treatment....

  16. Statistical techniques to extract information during SMAP soil moisture assimilation

    Science.gov (United States)

    Kolassa, J.; Reichle, R. H.; Liu, Q.; Alemohammad, S. H.; Gentine, P.

    2017-12-01

    Statistical techniques permit the retrieval of soil moisture estimates in a model climatology while retaining the spatial and temporal signatures of the satellite observations. As a consequence, the need for bias correction prior to an assimilation of these estimates is reduced, which could result in a more effective use of the independent information provided by the satellite observations. In this study, a statistical neural network (NN) retrieval algorithm is calibrated using SMAP brightness temperature observations and modeled soil moisture estimates (similar to those used to calibrate the SMAP Level 4 DA system). Daily values of surface soil moisture are estimated using the NN and then assimilated into the NASA Catchment model. The skill of the assimilation estimates is assessed based on a comprehensive comparison to in situ measurements from the SMAP core and sparse network sites as well as the International Soil Moisture Network. The NN retrieval assimilation is found to significantly improve the model skill, particularly in areas where the model does not represent processes related to agricultural practices. Additionally, the NN method is compared to assimilation experiments using traditional bias correction techniques. The NN retrieval assimilation is found to more effectively use the independent information provided by SMAP resulting in larger model skill improvements than assimilation experiments using traditional bias correction techniques.

  17. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    Science.gov (United States)

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  18. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  19. Application of PNA-technique for the measurement of multi-phase flow

    International Nuclear Information System (INIS)

    Loevhoeiden, G.; Andersen, E.; Garder, K.; Rambaek, J.P.

    1986-09-01

    The pulsed neutron activation (PNA) technique is proposed for multi-phase flow monitoring of hydrocarbons. The reactions 12 C(n,p) 12 B and 12 C(n,n') 12 C both yeld 4.4 MeV in the form of gamma radiation as a measure of carbon content. Intensity measurement of the 4.4 MeV gamma line gives a measure of the carbon content in the irradiation zone. By use of a pulsed neutron source, an estimation of the carbon content time variation is possible. In the presence of sulphur in petroleum, the reaction 34 S(n,p) 34 P offers a better possibility for flow rate determination

  20. Optimising the measurement of bruises in children across conventional and cross polarized images using segmentation analysis techniques in Image J, Photoshop and circle diameter measurements.

    Science.gov (United States)

    Harris, C; Alcock, A; Trefan, L; Nuttall, D; Evans, S T; Maguire, S; Kemp, A M

    2018-02-01

    Bruising is a common abusive injury in children, and it is standard practice to image and measure them, yet there is no current standard for measuring bruise size consistently. We aim to identify the optimal method of measuring photographic images of bruises, including computerised measurement techniques. 24 children aged Photoshop 'ruler' software (Photoshop diameter)). Inter and intra-observer effects were determined by two individuals repeating 11 electronic measurements, and relevant Intraclass Correlation Coefficient's (ICC's) were used to establish reliability. Spearman's rank correlation was used to compare in vivo with computerised measurements; a comparison of measurement techniques across imaging modalities was conducted using Kolmogorov-Smirnov tests. Significance was set at p 0.5 for all techniques, with maximum Feret diameter and maximum Photoshop diameter on conventional images having the strongest correlation with in vivo measurements. There were significant differences between in vivo and computer-aided measurements, but none between different computer-aided measurement techniques. Overall, computer aided measurements appeared larger than in vivo. Inter- and intra-observer agreement was high for all maximum diameter measurements (ICC's > 0.7). Whilst there are minimal differences between measurements of images obtained, the most consistent results were obtained when conventional images, segmented by Image J Software, were measured with a Feret diameter. This is therefore proposed as a standard for future research, and forensic practice, with the proviso that all computer aided measurements appear larger than in vivo. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.