WorldWideScience

Sample records for track-etched polycarbonate pc

  1. Influence of asymmetric etching on ion track shapes in polycarbonate

    International Nuclear Information System (INIS)

    Clochard, M.-C.; Wade, T.L.; Wegrowe, J.-E.; Balanzat, E.

    2007-01-01

    By combining low-energy ion irradiation with asymmetric etching, conical nanopores of controlled geometry can be etched in polycarbonate (PC). Cone bases vary from 0.5 to 1 μm. Top diameters down to 17 nm are reached. When etching from one side, the pH on the other side (bathed in neutral or acidic buffer) was monitored. Etching temperature ranged from 65 deg. C to 80 deg. C. Pore shape characterization was achieved by electro replication combined with SEM observation. The tip shape depended on whether an acidic buffer was used or not on the stopped side

  2. Electrochemical synthesis of gold nanorods in track-etched polycarbonate membrane using removable mercury cathode

    International Nuclear Information System (INIS)

    Sharma, Manoj K.; Ambolikar, Arvind S.; Aggarwal, Suresh K.

    2012-01-01

    The electrochemical template synthesis of gold nanorods within the cylindrical pores of track-etched polycarbonate (PC) membrane using a removable mercury cathode is reported. The novelty of this new approach is that it eliminates the requirement of coating an approximately 500 nm–1 μm-thick metallic layer, as conducting substrate, onto one surface of the insulating template membrane by the sputter deposition technique. A two-compartment electrochemical cell was designed and used for this work. The PC membrane was placed between the two compartments separating the aqueous solution of HAuCl 4 from mercury. Mercury, filled in one of the compartments, is in contact with one surface of the membrane (similar to sputter-deposited metallic layer) and serves as the conducting substrate/cathode for the electrochemical deposition of gold in the nanopores of track-etched PC membrane. Once the electrodeposition is completed, the mercury and the HAuCl 4 solution are removed from the compartments, and a malleable track-etched PC membrane embedded with free-standing gold nanorods is obtained. The ensemble of the metal nanorods grown in the template membrane is not attached to any conducting substrate, and gold nanorods can be freed from the template membrane after the dissolution. The Au-deposited PC membrane and free-standing Au nanorods were characterized by EDXRF, XRD, UV–Visible spectroscopy, AFM, and FEG-TEM. The EDXRF and XRD studies confirmed the deposition of the face-centered cubic phase of Au in the pores of the PC membrane. The TEM studies showed the formation of a cigar-shaped gold nanorod in the cylindrical pores of the PC membrane. The diameter of gold nanorods ranges from 100 to 200 nm. The new approach is simple, cost-effective, and saves time.

  3. Measurement of low neutron-fluences using electrochemically etched PC and PET track detectors

    International Nuclear Information System (INIS)

    Somogyi, G.; Dajko, G.; Turek, K.; Spurny, F.

    1979-01-01

    Systematic investigations have been carried out to study different properties of electrochemically etched (ECE) polycarbonate (PC) and polyethylene-terephthalate (PET) foils. The dependence of the density of background discharge spots on surface-thickness removal, electrical field strength and frequency of voltage is given. The effect of these parameters on the neutron sensitivity of polycarbonate and polyethylene-terephthalate foils irradiated at right angles to 14.7 MeV, 241 Am-Be and 252 Cf neutrons is also studied. With knowledge of the background and sensitivity data, the etching and electrical parameters are optimized for low neutron-fluence measurements. (author)

  4. Etched ion track polymer membranes for sustained drug delivery

    International Nuclear Information System (INIS)

    Rao, Vijayalakshmi; Amar, J.V.; Avasthi, D.K.; Narayana Charyulu, R.

    2003-01-01

    The method of track etching has been successfully used for the production of polymer membranes with capillary pores. In the present paper, micropore membranes have been prepared by swift heavy ion irradiation of polycarbonate (PC). PC films were irradiated with ions of gold, silicon and oxygen of varying energies and fluence. The ion tracks thus obtained were etched chemically for various time intervals to get pores and these etched films were used as membranes for the drug release. Ciprofloxacine hydrochloride was used as model drug for the release studies. The drug content was estimated spectrophotometrically. Pore size and thus the drug release is dependent on the etching conditions, ions used, their energy and fluence. Sustained drug release has been observed in these membranes. The films can be selected for practical utilization by optimizing the irradiation and etching conditions. These films can be used as transdermal patches after medical treatment

  5. Chemical etching studies of a Brazilian polycarbonate to fast neutron detection

    International Nuclear Information System (INIS)

    Souto, E.B.; Campos, L.L.

    2006-01-01

    The Dosimetric Materials Laboratory (LMD) of the Radiation Metrology Center (CMR) is developing a personal dosimeter for fast neutrons using the technique of solid state nuclear track detectors (SSNTD). This technique is based on the recorded damage (tracks) in dielectric materials due to the impact of charged particles. The tracks are revealed and amplified for visualization in optic microscope through a technique known as chemical etching. The LMD is investigating a Brazilian commercial polycarbonate as a new passive fast neutron's detector in substitution to the traditional materials, as the cellulose nitrate LR-115 and the polycarbonates Makrofol and CR-39. The variation of the etching parameters (chemical solution, time and temperature) alters the response of the material; the best revelation conditions provide the best relationship among the amount of revealed tracks, their clearness and the time spent for this. The polycarbonate studied is a resin of same chemical monomer of Makrofol (C,6H,403). Samples of 3 x 1 cm 2 of the polycarbonate were irradiated with 5 mSv of fast neutrons ( 241 Am-Be) and revealed with the chemical solution PEW-40 (15% KOH, 45% H 2 O, 40% C 2 H 5 OH), commonly used for Makrofol. The studied etching parameters were time and temperature. Groups of four samples were revealed at temperatures of 50, 65, 75, 90 and 100 C with etching times varying from one to six hours. The used track's counting procedure was that referred in the literature. The best response to fast neutrons was obtained at 75 C; in spite of their similar answers, smaller temperatures join larger uncertainties in the track's counting and poorer clearness. At this temperature, the number of revealed tracks increases with the etching time approximately until a plateau at three hours. For etching times higher than four hours the polycarbonate presents overlap of tracks. If the temperature is adjusted to 75 C, the etching time should be in the plateau to avoid that small

  6. Track-etched nanopores in spin-coated polycarbonate films applied as sputtering mask

    International Nuclear Information System (INIS)

    Nix, A.-K.; Gehrke, H.-G.; Krauser, J.; Trautmann, C.; Weidinger, A.; Hofsaess, H.

    2009-01-01

    Thin polycarbonate films were spin-coated on silicon substrates and subsequently irradiated with 1-GeV U ions. The ion tracks in the polymer layer were chemically etched yielding nanopores of about 40 nm diameter. In a second process, the nanoporous polymer film acted as mask for structuring the Si substrate underneath. Sputtering with 5-keV Xe ions produced surface craters of depth ∼150 nm and diameter ∼80 nm. This arrangement can be used for the fabrication of track-based nanostructures with self-aligned apertures.

  7. Chemical etching studies of a Brazilian polycarbonate to fast neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Souto, E.B.; Campos, L.L. [Instituto de Pesquisas Energeticas e Nucleares, IPEN- CNEN/SP Radiation Metrology Center (CMR) Av. Prof. Lineu Prestes, 2242 CEP: 05508-000 Sao Paulo - SP (Brazil)]. e-mail: ebsouto@ipen.br

    2006-07-01

    The Dosimetric Materials Laboratory (LMD) of the Radiation Metrology Center (CMR) is developing a personal dosimeter for fast neutrons using the technique of solid state nuclear track detectors (SSNTD). This technique is based on the recorded damage (tracks) in dielectric materials due to the impact of charged particles. The tracks are revealed and amplified for visualization in optic microscope through a technique known as chemical etching. The LMD is investigating a Brazilian commercial polycarbonate as a new passive fast neutron's detector in substitution to the traditional materials, as the cellulose nitrate LR-115 and the polycarbonates Makrofol and CR-39. The variation of the etching parameters (chemical solution, time and temperature) alters the response of the material; the best revelation conditions provide the best relationship among the amount of revealed tracks, their clearness and the time spent for this. The polycarbonate studied is a resin of same chemical monomer of Makrofol (C,6H,403). Samples of 3 x 1 cm{sup 2} of the polycarbonate were irradiated with 5 mSv of fast neutrons ({sup 241}Am-Be) and revealed with the chemical solution PEW-40 (15% KOH, 45% H{sub 2}O, 40% C{sub 2}H{sub 5}OH), commonly used for Makrofol. The studied etching parameters were time and temperature. Groups of four samples were revealed at temperatures of 50, 65, 75, 90 and 100 C with etching times varying from one to six hours. The used track's counting procedure was that referred in the literature. The best response to fast neutrons was obtained at 75 C; in spite of their similar answers, smaller temperatures join larger uncertainties in the track's counting and poorer clearness. At this temperature, the number of revealed tracks increases with the etching time approximately until a plateau at three hours. For etching times higher than four hours the polycarbonate presents overlap of tracks. If the temperature is adjusted to 75 C, the etching time should be in

  8. Influence of the particle discriminator for producing the microporous nuclear track etched membrane

    International Nuclear Information System (INIS)

    Thongphud, Apaporn; Ratanatongchai, Wichian; Supaphol, Pitt; Visal-athaphand, Pinpan

    2005-10-01

    The particle discriminator was used to focus the fission fragments from nuclear fission reaction between thermal neutron from the Thai Research Reactor and U-235 in uranium screen to strike almost normally to the polycarbonate (PC) film. The latent tracks in the thin 15 mm PC film were revealed after etching in 6N NaOH solution at 70 o C for 60 min. It was found that the tracks were porous. The porosity was more discrete and the pore shape was more circular as well. The track diameter was measured 3.73 +- 0.32 mm. It was also found that using particle discriminators with increasing thickness during exposure gives fewer pores in the PC film, after chemical etching under the same condition as above

  9. Effect of gamma irradiation on the etching properties of Lexan and Makrofol-DE polycarbonate plastics

    International Nuclear Information System (INIS)

    Ashok Kumar; Jain, R.K.; Praveen Yadav; Chakraborty, R.N.; Singh, B.K.; Nayak, B.K.

    2013-01-01

    It is observed that for Lexan and Makrofol-DE polycarbonate plastic detectors the mean diameters of fission fragments from a 252 Cf source increases as a result of gamma-ray exposure. We have studied the bulk etching rate and track etching rate before and after gamma-ray irradiation on Lexan and Makrofol-DE polycarbonate plastics. The mechanism of Lexan and Makrofol-DE polycarbonate plastic detectors can be understood with the help of this exposures. It is also noted that degree of ordering of Lexan and Makrofol-DE polycarbonate is dependent on the gamma ray dose due to degradation and cross-linking processes. The results show that bulk and track etch rate increases with gamma dose while activation energy associated with bulk and track etch rates at a particular temperature and sensitivity decreases with gamma dose. (author)

  10. Etching microscopic defects in polycarbonate due to high dose ArF or KrF laser exposure

    Energy Technology Data Exchange (ETDEWEB)

    Jaleh, B. [Physics Department, Bu- Alisina University, Hamadan (Iran, Islamic Republic of); Parvin, P. [Physics Department, Amirkabir University, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of) and Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of) ]. E-mail: parvin@aut.ac.ir; Katoozi, M. [National Radiation Protection Department, AEOI, Tehran (Iran, Islamic Republic of); Zamani, Z. [Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of); Zare, A. [Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of)

    2005-11-15

    The ArF or KrF excimer laser exposure on the polycarbonate (PC) with corresponding doses higher than {phi}{sub th}5.2J/cm{sup 2}, at 32mJ/cm{sup 2} fluence per pulse and 5Hz pulse repetition rate (PRR), induces regular defects leading to self assembled defect structure following electrochemical etching (ECE). We have observed the conical-like structure for {phi}>{phi}{sub th}, whereas the polymer experiences hardening effect due to crosslinking when {phi}<{phi}{sub th}. Subsequently, conical-like, structure turns into track-like pits developing under ECE multiple treeing. Self assembled defect structure may be seen by naked eye as white spots, despite SEM illustrates a type of periodic pit formation-morphology. The exact explanation of the effect is not well understood yet. It looks like alpha tracks in the polymer surface, however the PC pieces were simply treated by excimer lasers at high doses, and they have not been exposed to the nuclear particles afterwards. We could not observe those effects at 308nm (XeCl laser) or longer wavelengths at 351nm (XeF laser) where UV photoablation does not occur. It indicates that UV ablation establishes surface degradation at shorter wavelengths, leading to laser micro etching. The mean track (defect) density is about one order of magnitude greater than the normal alpha tracks. Increasing UV doses, polymer undergoes a plateau, corresponding to etched defect saturation on PC.

  11. Etching microscopic defects in polycarbonate due to high dose ArF or KrF laser exposure

    International Nuclear Information System (INIS)

    Jaleh, B.; Parvin, P.; Katoozi, M.; Zamani, Z.; Zare, A.

    2005-01-01

    The ArF or KrF excimer laser exposure on the polycarbonate (PC) with corresponding doses higher than φ th 5.2J/cm 2 , at 32mJ/cm 2 fluence per pulse and 5Hz pulse repetition rate (PRR), induces regular defects leading to self assembled defect structure following electrochemical etching (ECE). We have observed the conical-like structure for φ>φ th , whereas the polymer experiences hardening effect due to crosslinking when φ th . Subsequently, conical-like, structure turns into track-like pits developing under ECE multiple treeing. Self assembled defect structure may be seen by naked eye as white spots, despite SEM illustrates a type of periodic pit formation-morphology. The exact explanation of the effect is not well understood yet. It looks like alpha tracks in the polymer surface, however the PC pieces were simply treated by excimer lasers at high doses, and they have not been exposed to the nuclear particles afterwards. We could not observe those effects at 308nm (XeCl laser) or longer wavelengths at 351nm (XeF laser) where UV photoablation does not occur. It indicates that UV ablation establishes surface degradation at shorter wavelengths, leading to laser micro etching. The mean track (defect) density is about one order of magnitude greater than the normal alpha tracks. Increasing UV doses, polymer undergoes a plateau, corresponding to etched defect saturation on PC

  12. Analysis of etchants behavior on the electrochemical etching amplification of fast-neutron-induced recoil particle tracks in polycarbonate

    International Nuclear Information System (INIS)

    Masnadi Shirazi Nezhad, K.

    1979-08-01

    The composition, concentration, and temperature of etchant are important parameters controlling electrochemical etching (ECE) amplification of charged particle tracks in polymers. These parameters were further studied for sohralir polycarbonate neutron dosimeter (Sohrabi 1974), using potassium hydroxide (KOH) and sodium hydroxide (NaOH) solutions, and a mixture of potassium hydroxide, ethanol, and water (PEW solution), at different concentrations applying a field strength of 32KV/cm at 2KHz frequency using 250 μ thick polycarbonate exposed to fast neutrons. The recoal track density per rad of neutrons, in general, was found to increase by increasing the etchant concentration reaching a semi-platean after which it increases again. This increase is up to a concentration at which a track removing process occurs and no tracks have been amplified anymore. This track removing process occurred at about 11 normality in both KOH (50% by weight) and NaOH (30% by weight) solution at 25degC. The mean track diameter, in general, passed through a cyclic variation having a maximun and a minimum. For NaOH solution, the track removing process occurred at the minimum point. In the three regions of the track diameter curve the tracks appear in different shapes especially in KOH solution. The PEW solution at its optimum conditions was more effective in terms of both sensitivity, track diameter and a shorter period of etching. The chemical mechanism of etching process may be explained to be a ''saponification'' process. These studies further support the adequacy of Sohrabi dosimeter for routing health physics and radiation research applications. The above parameters are further discussed and the results as well as the advantages and disadvantages of the above etchants are given. (author)

  13. The spark counting of etched fission-fragment tracks in polycarbonate for a personal neutron dosimetry system

    International Nuclear Information System (INIS)

    Harrison, K.G.; Hancock, I.B.; Holt, P.D.; Wylie, J.W.

    1977-10-01

    A new type of personal neutron dosimeter, in which neutron-induced fissions in a thin 237 Np foil are detected by a polycarbonate track-detector, is under development at Harwell for use in a nuclear-fuel reprocessing plant. As part of the development programme, an experimental dosimeter, etching facility and spark counter have been used to study the spark-counting method for counting fission-fragment tracks in polycarbonate. Emphasis has been placed on developing operating procedures for the counter consistent with good overall reproducibility. Existing methods for the optimizing and testing of spark counters is briefly reviewed and a practical operational testing procedure is devised. The optimized system is found to be relatively foolproof in operation and gives good results in unskilled use as well as under carefully-controlled laboratory conditions. (author)

  14. Method of plastic track detector electrochemical etching

    International Nuclear Information System (INIS)

    D'yakov, A.A.

    1984-01-01

    The review of studies dealing with the development of the method for the electro-chemical etching (ECE) of the plastic track detectors on the base of polyethy-leneterephthalate (PET) and polycarbonate (PC) is given. Physical essence of the method, basic parameters of the processes, applied equipment and methods of measurement automation are considered. The advantages of the method over the traditional chemical etching are pointed out. Recommendations on the detector operation modes when detecting fission fragments, α-particles and fast neutrons are given. The ECE method is based on the condition that during chemical etching the high-voltage sound frequency alternating electric field is applied to the detector. In this case the detector serves as an isolating layer betWeen two vessels with etching solution in which high-voltage electrode are submerged. At a fixed electric field potential higher (over than the threshold value) at the end of the etching track cone atree-like discharge spot arises. It is shown that when PET is used for fast neutron detection it is advisable to apply for ECE the PEW solution (15g KOH+40 g C 2 H 2 OH + 45g H 2 O) the field potential should constitute 30 kVxcm -1 at the freqUency of 9 kHz. In the case of fission fragment detection Using ECE and PC the following ECE conditions are recommended: 30% KOH etcher, field potential of 10 kVxcm -1 , 2-4 kHz frequency. It is concluded that the ECE method permits considerably eXtend the sphere of plastic track detector application for detecting ionizing particles,

  15. Determination by Small-angle X-ray Scattering of Pore Size Distribution in Nanoporous Track-etched Polycarbonate Membranes

    Science.gov (United States)

    Jonas, A. M.; Legras, R.; Ferain, E.

    1998-03-01

    Nanoporous track-etched membranes with narrow pore size distributions and average pore size diameters tunable from 100 to 1000 Åare produced by the chemical etching of latent tracks in polymer films after irradiation by a beam of accelerated heavy ions. Nanoporous membranes are used for highly demanding filtration purposes, or as templates to obtain metallic or polymeric nanowires (L. Piraux et al., Nucl. Instr. Meth. Phys. Res. 1997, B131, 357). Such applications call for developments in nanopore size characterization techniques. In this respect, we report on the characterization by small-angle X-ray scattering (SAXS) of nanopore size distribution (nPSD) in polycarbonate track-etched membranes. The obtention of nPSD requires inverting an ill-conditioned inhomogeneous equation. We present different numerical routes to overcome the amplification of experimental errors in the resulting solutions, including a regularization technique allowing to obtain the nPSD without a priori knowledge of its shape. The effect of deviations from cylindrical pore shape on the resulting distributions are analyzed. Finally, SAXS results are compared to results obtained by electron microscopy and conductometry.

  16. Comparison of fast neutron-induced tracks in plastics using the electrochemical etching method

    International Nuclear Information System (INIS)

    Cotter, S.J.; Gammage, R.B.; Thorngate, J.H.; Ziemer, P.L.

    1979-01-01

    Four plastics were examined by the electrochemical etching method for their suitability in registering fast neutron-induced recoil particle tracks. The plastics were cellulose acetate, cellulose triacetate, cellulose acetobutyrate and polycarbonate. Cellulose acetate and triacetate displayed high levels of water absorptivity during etching while the acetobutyrate foils cracked due to electromechanical stresses at high frequencies (>500 Hz). The clarity of the etched track was superior in the polycarbonate foils, suggesting the latter as the generally preferred dosimeter for fast neutrons. (author)

  17. A comparative study of track registration response of Makrofol-(KG, KL and N) polycarbonate to sup 4 sup 0 Ar ions

    CERN Document Server

    Kumar, A

    1999-01-01

    In the present work a comparative study of track registration response of sup 4 sup 0 Ar ions in different types of Makrofol polycarbonates viz. Makrofol-KG, KL and N have been done. The etched track parameters viz. bulk etch rate, track etch rate, etch rate ratio, cone angle and etching efficiency were calculated. The variation of etching rates with temperature were found to be exponential and follow the Arrhenius equation. The values of activation energy for bulk and track etching were also calculated. Maximum etchable track length/range were also obtained and compared with the theoretical values obtained from computer program RANGE. From the results it is found that the polycarbonates having same chemical composition manufactured by different chemical processes have slightly different behavior

  18. Magnetoelectrolysis of Co nanowire arrays grown in a track-etched polycarbonate membrane

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Barriga, J. [Instituto de Magnetismo Aplicado (UCM-RENFE-CSIC), P.O. Box 155, 28230, Las Rozas, Madrid (Spain)]. E-mail: sbarriga@bessy.de; Lucas, M. [Technische Universitaet Berlin, Institut fuer Theoretische Physik, Hardenbergstr. 36, D-10623 Berlin (Germany); Rivero, G. [Instituto de Magnetismo Aplicado (UCM-RENFE-CSIC), P.O. Box 155, 28230, Las Rozas, Madrid (Spain); Marin, P. [Instituto de Magnetismo Aplicado (UCM-RENFE-CSIC), P.O. Box 155, 28230, Las Rozas, Madrid (Spain); Hernando, A. [Instituto de Magnetismo Aplicado (UCM-RENFE-CSIC), P.O. Box 155, 28230, Las Rozas, Madrid (Spain)

    2007-05-15

    Arrays of Cobalt nanowires with a controlled length of 6{mu}m have been fabricated by electrochemical deposition into the pores of track-etched polycarbonate membranes with a nominal pore diameter of 30nm. The magnetic properties of Co-deposited nanowires and the effects of a magnetic field applied during electrodeposition of the arrays have been studied. An enhancement of the mass deposition rate due to the presence of a 50Oe magnetic field along the nanowire axis has been observed by measuring the experimental development of the current in the electrochemical cell during the fabrication process. X-ray diffraction measurements reveal a different polycrystalline degree for each deposition configuration, indicating that the crystalline structure of the deposited material has been substantially modified. Magnetic measurements show a clear dependence of the anisotropy directions on the orientation of the magnetic field applied during the electrodeposition.

  19. Magnetoelectrolysis of Co nanowire arrays grown in a track-etched polycarbonate membrane

    International Nuclear Information System (INIS)

    Sanchez-Barriga, J.; Lucas, M.; Rivero, G.; Marin, P.; Hernando, A.

    2007-01-01

    Arrays of Cobalt nanowires with a controlled length of 6μm have been fabricated by electrochemical deposition into the pores of track-etched polycarbonate membranes with a nominal pore diameter of 30nm. The magnetic properties of Co-deposited nanowires and the effects of a magnetic field applied during electrodeposition of the arrays have been studied. An enhancement of the mass deposition rate due to the presence of a 50Oe magnetic field along the nanowire axis has been observed by measuring the experimental development of the current in the electrochemical cell during the fabrication process. X-ray diffraction measurements reveal a different polycrystalline degree for each deposition configuration, indicating that the crystalline structure of the deposited material has been substantially modified. Magnetic measurements show a clear dependence of the anisotropy directions on the orientation of the magnetic field applied during the electrodeposition

  20. Surface effect of KrF laser exposure on ECE of alpha particle tracks in polycarbonate polymer

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, P. [Physics Department, Amirkabir University, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of) and Laser Research Center, Atomic Energy Organization of Iran, AEOI, Tehran (Iran, Islamic Republic of)]. E-mail: parvin@aut.ac.ir; Jaleh, B. [Physics Department, Bu Ali Sina University, Hamadan (Iran, Islamic Republic of); Sheikh, N. [Gamma Irradiation Center, AEOI, Tehran (Iran, Islamic Republic of); Amiri, N. [Physics Department, Emam Hossien University, Tehran (Iran, Islamic Republic of)

    2005-11-15

    The optical penetration depth for polycarbonate (PC) at 308nm due to XeCl laser is about 450{mu}m while those of KrF (248nm) and ArF (193nm) lasers become noticeably shorter to 1{mu}m and 20nm, respectively, to show the strong superficial absorption at shorter UV wavelengths. On the other hand, KrF laser exposure on polycarbonate, at doses above 6J/cm{sup 2}, creates the surface crosslinking. In spite of several reliable methods available, such as 'hot set' and 'gel content', to determine the bulk crosslinking, there are a few consistent techniques to evaluate the surface crosslinking effect quantitatively. It includes hardening measurements using nanoindenter or AFM (atomic force microscopy). In this work, we present a technique for the measurement of superficial crosslinking, based on electrochemical etching of alpha irradiated polycarbonate accordingly. The mean diameter of the developed tracks nonlinearly decreases for KrF laser treatment at higher doses. The relative shrinkage of track diameters due to UV exposure before alpha irradiation, comparing to those without UV pre-radiation, indicates that UV laser makes the polymer surface hardened. The variation of mean track diameters can be strongly used to quantify the surface crosslinking.

  1. Surface effect of KrF laser exposure on ECE of alpha particle tracks in polycarbonate polymer

    International Nuclear Information System (INIS)

    Parvin, P.; Jaleh, B.; Sheikh, N.; Amiri, N.

    2005-01-01

    The optical penetration depth for polycarbonate (PC) at 308nm due to XeCl laser is about 450μm while those of KrF (248nm) and ArF (193nm) lasers become noticeably shorter to 1μm and 20nm, respectively, to show the strong superficial absorption at shorter UV wavelengths. On the other hand, KrF laser exposure on polycarbonate, at doses above 6J/cm 2 , creates the surface crosslinking. In spite of several reliable methods available, such as 'hot set' and 'gel content', to determine the bulk crosslinking, there are a few consistent techniques to evaluate the surface crosslinking effect quantitatively. It includes hardening measurements using nanoindenter or AFM (atomic force microscopy). In this work, we present a technique for the measurement of superficial crosslinking, based on electrochemical etching of alpha irradiated polycarbonate accordingly. The mean diameter of the developed tracks nonlinearly decreases for KrF laser treatment at higher doses. The relative shrinkage of track diameters due to UV exposure before alpha irradiation, comparing to those without UV pre-radiation, indicates that UV laser makes the polymer surface hardened. The variation of mean track diameters can be strongly used to quantify the surface crosslinking

  2. Fabrication of nanoporous nuclear track membranes

    International Nuclear Information System (INIS)

    Peng Liangqiang; Wang Shicheng; Ju Xin; Masaru Yoshida; Yasunari Maekawa

    2001-01-01

    Polyethylene terephthalate (PET) and polycarbonate (PC) films were irradiated by S, Kr and Xe ions and were illuminated with ultraviolet light. The normalized track etch rate for PET and PC films etched in different conditions were measured by conductometric experiments. It is shown that normalized track etch rate can be over 1000 for PET films, 2000 for PC films under optimized condition. TEM photographs of copper nanowires electroplated into nanoporous nuclear track membranes show that the narrowest wire diameter of copper nanowires is 20 nm and that the pore diameter calculated by conductometric experiments is in agreement with the wire diameter measured by TEM when the pore diameter is over 30 nm

  3. Applications for Track-etched Templates and Films

    International Nuclear Information System (INIS)

    Ferain, E.

    2006-01-01

    Track etching technology of first generation is mainly used for the production of self-supported membranes made of polycarbonate (PC) or polyethylene terephthalate (PET) with randomly distributed pores. Typical membrane thickness is between 10 and 20 microns and pore size is in the range 0,1 μm to 10 μm. Second generation track etching technology overcomes many of limitations and offers new advantages : true nanopores down to 10 nm with well-controlled pore shape in a large range of pore densities, use of polymer (polyimide-PI) resistant to high temperature (up to 430 degree), ability to track etch a thin polymeric layer deposited on a substrate (such as glass, quartz, silicon, oxides, ...) and ability to confine nanopores into zones as small as 10 micron square (patterning process). This second generation technology, when applied to larger pore size, also contributes to a better membrane with potential benefits as e.g. a more precise cut-off. Another feature of the second generation technology is the patterning of the polymer layers - i.e. the nanopores can be grown in defined areas of the polymer layers. Smart membranes are used as separation barriers and flow controllers in devices such as chemical and biochemical sensors and analysers (lab on a chip, microtitre plates, ...). For example, a specific track etched membrane has been designed to be used as a selective separation barrier in a project intends to develop, improve and validate an efficient reliable bioartificial pancreas for human application. A variety of materials (metals, semiconductors, oxides, heterostructures) can be deposited into the pores as nanowires or nanotubes; these structures can be produced with over wide range of aspect ratios with excellent shape control, and can be either used in-situ or easily harvested by simple chemical dissolution

  4. Tracking of Polycarbonate Films using Low-energy Ions Final Report CRADA No. TC-774-94

    Energy Technology Data Exchange (ETDEWEB)

    Musket, R. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2018-01-24

    Ion tracking is performed almost exclusively using ions with energies near or above the maximum in electronic stopping. For the present study, we have examined the results of etching ion tracks created by ions bombarding polycarbonate films with energies corresponding to stopping well below the maximum and just above the anticipated threshold for creating etchable latent tracks. Low-energy neon and argon ions with 18-60 keV /amu and fluences of about 108/cm2 were used to examine the limits for producing etchable tracks in polycarbonate films. By concentrating on the early stages of etching (i.e., -20 nm < SEM hole diameter < -100 nm), we can directly relate the energy deposition calculated for the incident ion to the creation of etchable tracks. The experimental results will be discussed with regard to the energy losses of the ions in the polycarbonate films and to the formation of continuous latent tracks through the entire thickness the films. These results have significant implications with respect to the threshold for formation of etchable tracks and to the use of low-energy ions for lithographic applications.

  5. Study on the etching conditions of polycarbonate detectors for particle analysis of safeguards environmental samples

    International Nuclear Information System (INIS)

    Iguchi, K.; Esaka, K.T.; Lee, C.G.; Inagawa, J.; Esaka, F.; Onodera, T.; Fukuyama, H.; Suzuki, D.; Sakurai, S.; Watanabe, K.; Usuda, S.

    2005-01-01

    The fission track technique was applied to the particle analysis for safeguards environmental samples to obtain information about the isotope ratio of nuclear materials in individual particles. To detect the particles containing nuclear material with high detection efficiency and less particle loss, the influence of uranium enrichments on etching conditions of a fission track detector made of polycarbonate was investigated. It was shown that the increase in uranium enrichment shortened the suitable etching time both for particle detection and for less particle loss. From the results obtained, it was suggested that the screening of the uranium particles according to the enrichment is possible by controlling the etching time of the detector

  6. A novel method for observation by unaided eyes of nitrogen ion tracks and angular distribution in a plasma focus device using 50 Hz–HV electrochemically-etched polycarbonate detectors

    International Nuclear Information System (INIS)

    Sohrabi, M.; Habibi, M.; Roshani, G.H.; Ramezani, V.

    2012-01-01

    A novel ion detection method has been developed and studied in this paper for the first time to detect and observe tracks of nitrogen ions and their angular distribution by unaided eyes in the Amirkabir 4 kJ plasma focus device (PFD). The method is based on electrochemical etching (ECE) of nitrogen ion tracks in 1 mm thick large area polycarbonate (PC) detectors. The ECE method employed a specially designed and constructed large area ECE chamber by applying a 50 Hz–high voltage (HV) generator under optimized ECE conditions. The nitrogen ion tracks and angular distribution were efficiently (constructed for this study) amplified to a point observable by the unaided eyes. The beam profile and angular distribution of nitrogen ion tracks in the central axes of the beam and two- and three-dimensional iso-ion track density distributions showing micro-beam spots were determined. The distribution of ion track density along the central axes versus angular position shows double humps around a dip at the 0° angular positions. The method introduced in this paper proved to be quite efficient for ion beam profile and characteristic studies in PFDs with potential for ion detection studies and other relevant dosimetry applications.

  7. Surfactant-controlled etching of ion track nanopores and its practical applications in membrane technology

    International Nuclear Information System (INIS)

    Apel, P.Yu.; Blonskaya, I.V.; Dmitriev, S.N.; Mamonova, T.I.; Orelovitch, O.L.; Sartowska, B.; Yamauchi, Yu.

    2008-01-01

    The effect of surfactants on chemical development of ion tracks in polymers has been studied. It has been shown that surface-active agents added to an alkaline etching solution adsorb on the polymer surface at the pore entrances. This reduces the etch rate, which leads to the formation of pores tapered toward the surface. Self-assembly of surfactant molecules at the pore entrance creates a barrier for their penetration into the etched-out nanopores, whereas hydroxide ions diffuse freely. Due to this, the internal pore volume grows faster than the pore surface diameter. The ability to control pore shape is demonstrated with the fabrication of profiled nano- and micropores in polyethylene terephthalate, polycarbonate. Some earlier published data on small track-etched pores in polycarbonate (in particular, the pore diameter vs. etching time curves measured conductometrically) have been revised in light of the above findings. Adding surfactants to chemical etchants makes it possible to optimize the structure of track membranes, thus improving their retention and permeation properties. Asymmetric membranes with thin skin retention layers have been produced and their performance studied

  8. On the penetration of etchant into tracks in polycarbonate

    International Nuclear Information System (INIS)

    Fink, D.; Dwivedi, K.K.; Mueller, M.; Ghosh, S.; Hnatowicz, V.; Vacik, J.; Cervena, J.

    2000-01-01

    The time dependence of the uptake of NaOH/LiOH etchant in pristine polycarbonate (PC) and in PC irradiated with 3 GeV Pb ions has been examined. Different stages of etchant penetration can be distinguished. The overall surface-near etchant uptake along tracks is always higher than the the one of the nonirradiated pristine material. Furthermore, the directional dependence of the etchant penetration during the incubation time is studied. Though the shapes of the etchant distributions along the tracks are practically the same in all directions, they differ in their absolute magnitudes. This can be explained by the different cross-sectional track areas exposed at the surface, which enable different etchant penetration efficiencies. Therefore, tracks which run more or less parallel to the surface normal show less etchant uptake than those being strongly tilted

  9. Thermal stability of dyed tracks and electrochemical etching sensitivity of some polymeric detectors

    International Nuclear Information System (INIS)

    Monnin, M.; Gourcy, J.; Somogyi, G.; Dajko, D.

    1980-01-01

    Recent results on the mechanism of the formation of tracks obtained by the dyed tracks technique are given and the thermal annealing of the detectors is used to demonstrate their ability to retain tracks under more severe conditions than by the etching technique. Electrochemical etching of polycarbonate and polyethylene terephthalate detectors is investigated both from the background and sensitivity points of view. The polyethylene terephthalate detector is shown to be well suited for low neutron flux measurements. (author)

  10. Excimer laser beam profile recording based on electrochemical etched polycarbonate

    International Nuclear Information System (INIS)

    Parvin, P.; Jaleh, B.; Zangeneh, H.R.; Zamanipour, Z.; Davoud-Abadi, Gh.R.

    2008-01-01

    There is no polymeric detector used to register the beam profile of UV lasers. Here, a method is proposed for the measurement of intensive UV beam pattern of the excimer lasers based on the photoablated polycarbonate detector after coherent UV exposure and the subsequent electrochemical etching. UV laser induced defects in the form of self-microstructuring on polycarbonate are developed to replicate the spatial intensity distribution as a beam profiler

  11. Excimer laser beam profile recording based on electrochemical etched polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Parvin, P. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of); Laser Research Center, AEOI, P.O. Box 1165-8486, Tehran (Iran, Islamic Republic of)], E-mail: parvin@aut.ac.ir; Jaleh, B. [Physics Department, Bu-Ali Sina University, Postal Code 65174, Hamedan (Iran, Islamic Republic of); Zangeneh, H.R. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of); Zamanipour, Z. [Laser Research Center, AEOI, P.O. Box 1165-8486, Tehran (Iran, Islamic Republic of); Davoud-Abadi, Gh.R. [Physics Department, Amirkabir University of Technology, P.O. Box 15875-4413, Hafez Ave, Tehran (Iran, Islamic Republic of)

    2008-08-15

    There is no polymeric detector used to register the beam profile of UV lasers. Here, a method is proposed for the measurement of intensive UV beam pattern of the excimer lasers based on the photoablated polycarbonate detector after coherent UV exposure and the subsequent electrochemical etching. UV laser induced defects in the form of self-microstructuring on polycarbonate are developed to replicate the spatial intensity distribution as a beam profiler.

  12. Track-Etched Magnetic Micropores for Immunomagnetic Isolation of Pathogens

    Science.gov (United States)

    Muluneh, Melaku; Shang, Wu

    2014-01-01

    A microfluidic chip is developed to selectively isolate magnetically tagged cells from heterogeneous suspensions, the track-etched magnetic micropore (TEMPO) filter. The TEMPO consists of an ion track-etched polycarbonate membrane coated with soft magnetic film (Ni20Fe80). In the presence of an applied field, provided by a small external magnet, the filter becomes magnetized and strong magnetic traps are created along the edges of the micropores. In contrast to conventional microfluidics, fluid flows vertically through the porous membrane allowing large flow rates while keeping the capture rate high and the chip compact. By utilizing track-etching instead of conventional semiconductor fabrication, TEMPOs can be fabricated with microscale pores over large areas A > 1 cm2 at little cost ( 500 at a flow rate of Φ = 5 mL h−1. Furthermore, the large density of micropores (ρ = 106 cm−2) allows the TEMPO to sort E. coli from unprocessed environmental and clinical samples, as the blockage of a few pores does not significantly change the behavior of the device. PMID:24535921

  13. Radiation resistance of track etched membranes

    International Nuclear Information System (INIS)

    Buczkowski, M.; Sartowska, B.; Wawszczak, D.; Starosta, W.

    2001-01-01

    Track etched membranes (TEMs) obtained by irradiation of polymer films with heavy ions and subsequent etching of latent tracks can be applied in many fields and among others in biomedicine as well. It is important to know radiation resistance of TEMs because of wide use of radiation sterilization in the case of biomedical devices. Tensile properties of TEMs made of PET and PC films with the thickness of 10 μm after electron irradiation at different doses are known from literature. Nowadays TEMs are being manufactured from thicker (20 μm) PET and PC films as well as polyethylene naphthalate (PEN) films are proposed for TEMs. It seems to be important to get data about radiation resistance of new kinds of TEMs. Samples of polymer films made of PET and PEN with the thickness of 19-25 μm and TEMs made of such materials have been irradiated using 10 MeV electron beam with doses up to 990 kGy. Tensile properties and SEM photographs of the samples after irradiation are given in the paper

  14. Neutron dosimetry using electrochemical etching

    International Nuclear Information System (INIS)

    Su, S.J.; Stillwagon, G.B.; Morgan, K.Z.

    1977-01-01

    Registration of α-tracks and fast-neutron-induced recoils tracks by the electrochemical etching technique as applied to sensitive polymer foils (e.g., polycarbonate) provides a simple, sensitive and inexpensive means of fast neutron personnel dosimetry as well as a valuable research tool for microdosimetry. When tracks were amplified by our electrochemical technique and the etching results compared with conventional etching technique a striking difference was noted. The electrochemically etched tracks were of much larger diameter (approx. 100 μm) and gave superior contrast. Two optical devices--the transparency projector and microfiche reader--were adapted to facilitate counting of the tracks appearing on our polycarbonate foils. The projector produced a magnification of 14X for a screen to projector distance of 5.0 meter and read's magnification was 50X. A Poisson distribution was determined for the number of tracks located in a particular area of the foil and experimentally verified by random counting of quarter sections of the microfiche reader screen. Finally, in an effort to determine dose equivalent (rem), a conversion factor is being determined by finding the sensitivity response (tracks/neutron) of recoil particle induced tracks as a function of monoenergetic fast neutrons and comparing results with those obtained by others

  15. An experimental study of the fabrication of polycarbonate optical waveguides

    Science.gov (United States)

    Chen, Jianguo; Zhang, Xiao-yang; Zhang, Tong; Zhu, Jing-song; Wu, Peng-qin; Zhou, Jing-lun; Fan, Jiang-feng; Yan, Hao-feng

    2008-12-01

    A novel polycarbonate (PC) was introduced to apply in the optical waveguide devices. PC has following distinct merits than common polycarbonate: good processability, high thermal stability up to 293 C° and high optical transparency. Optical properties of absorption behavior and propagation loss were investigated in slab waveguides, and low propagation losses of 0.335 dB/cm (@1550nm) and 0.197 dB/cm @632.8nm) have been achieved by using prismcoupler. Additionally, straight optical waveguide and MMI coupler of ring resonator were fabricated using ultraviolet (UV) cured resin Norland optical adhesive 61 (NOA61) as under or upper cladding layer and polycarbonate as waveguide core-layer material through conventional methods such as spin coating, photolithography and reactive ion etching (RIE). The process was studied in detail and the experimental results were given.

  16. Electrochemical etching amplification of low-let recoil particle tracks in polymers for fast neutron dosimetry

    International Nuclear Information System (INIS)

    Sohrabi, M.; Morgan, K.Z.

    1975-11-01

    An electrochemical etching method for the amplification of fast-neutron-induced recoil particle tracks in polymers was investigated. The technique gave superior results over those obtained by conventional etching methods especially when polycarbonate foils were used for recoil particle track amplification. Electrochemical etching systems capable of multi-foil processing were designed and constructed to demonstrate the feasibility of the techniques for large-scale neutron dosimetry. Electrochemical etching parameters were studied including the nature or type of the polymer foil used, foil thickness and its effect on etching time, the applied voltage and its frequency, the chemical composition, concentration, and temperature of the etchant, distance and angle between the electrodes, and the type of particles such as recoil particles including protons. Recoil particle track density, mean track diameter, and optical density as functions of the mentioned parameters were determined. Each parameter was found to have a distinct effect on the etching results in terms of the measured responses. Several new characteristics of this fast neutron dosimetry method were studied especially for personnel dosimetry using various radiation sources such as nuclear reactors, medical cyclotrons, and isotopic neutron sources. The dose range, neutron energy dependence, directional response, fading characteristics, neutron threshold energy, etc. were investigated

  17. A spatial track formation model and its use for calculating etch-pit parameters of light nuclei

    International Nuclear Information System (INIS)

    Somogyi, G.; Scherzer, R.; Grabisch, K.; Enge, W.

    1976-01-01

    A generalized geometrical model of etch-pit formation in three dimensions is presented for nuclear particles entering isotropic solids at arbitrary angles of incidence. With this model one can calculate the relations between any particle parameter /Z = charge, M = mass, R = range, theta = angle of incidence/ and etching or track parameter /h = removed detector layer, L = track length, d = track diameter, etch-pit profile and contour/ for track etching rates varying monotonically along the trajectory of particles. Using a computer algorithm, calculations have been performed to study identification problems of nuclei of Z = 1-8 registered in a stack of polycarbonate sheets. For these calculations the etching rate ratio vs residual range curves were parametrized with a form of V -1 (R) = 1-Σasub(i) exp (- bsub(i)R) which does not involve the existence of a threshold for track registration. Particular attention was paid to the study of the evolution of etch-pit sizes for relatively high values of h. For this case, data are presented for the charge and isotope resolving power of the identification methods based on the relations L(R) of d(R). Calculations were also made to show the effect of the relative /parallel and opposite/ orientations between the directions of track etching and particle speed on etch-pit evolution. These studies offered new identification methods based on the determination of the curves L(parallel) vs L(opposite) and d(parallel) vs d(opposite), respectively. (orig.) [de

  18. Controlled ion track etching

    Science.gov (United States)

    George, J.; Irkens, M.; Neumann, S.; Scherer, U. W.; Srivastava, A.; Sinha, D.; Fink, D.

    2006-03-01

    It is a common practice since long to follow the ion track-etching process in thin foils via conductometry, i.e . by measurement of the electrical current which passes through the etched track, once the track breakthrough condition has been achieved. The major disadvantage of this approach, namely the absence of any major detectable signal before breakthrough, can be avoided by examining the track-etching process capacitively. This method allows one to define precisely not only the breakthrough point before it is reached, but also the length of any non-transient track. Combining both capacitive and conductive etching allows one to control the etching process perfectly. Examples and possible applications are given.

  19. Development of etched nuclear tracks

    International Nuclear Information System (INIS)

    Somogyi, G.

    1980-01-01

    The theoretical description of the evolution of etched tracks in solid state nuclear track detectors is considered for different initial conditions, for the cases of constant and varying track etch rates, isotropic and anisotropic bulk etching as well as for thick and thin detectors. It is summarized how one can calculate the main parameters of etch-pit geometry, the track length, the axes of a surface track opening, track profile and track contour. The application of the theory of etch-track evolution is demonstrated with selected practical problems. Attention is paid to certain questions related to the determination of unknown track parameters and calculation of surface track sizes. Finally, the theory is extended to the description of the perforation and etch-hole evolution process in thin detectors, which is of particular interest for track radiography and nuclear filter production. (orig.)

  20. Development of etched nuclear tracks

    International Nuclear Information System (INIS)

    Somogyi, G.

    1979-01-01

    The theoretical description of the evolution of etched tracks in solid state nuclear track detectors is considered for different initial conditions, for the cases of constant and varying track etch rates, isotopic and unisotropic bulk etching as well as for thick and thin detectors. It is summarized how the main parameters of etch-pit geometry, the track length, the axes of a surface track opening, the track profile and the track contour can be calculated. The application of the theory of etch-track evolution is demonstrated with selected practical problems. Attention is paid to certain questions related to the determination of unknown track parameters and calculation of surface track sizes. Finally, the theory is extended to the description of the perforation and etch-hole evolution process in thin detectors, which is of particular interest for track radiography and nuclear filter production. (author)

  1. Latent tracks in polymeric etched track detectors

    International Nuclear Information System (INIS)

    Yamauchi, Tomoya

    2013-01-01

    Track registration properties in polymeric track detectors, including Poly(allyl diglycol carbonate), Bispenol A polycarbonate, Poly(ethylen terephtarate), and Polyimide, have been investigated by means of Fourie transform Infararede FT-IR spectrometry. Chemical criterion on the track formation threshold has been proposes, in stead of the conventional physical track registration models. (author)

  2. New development on electrochemical etching processes at the Atomic Energy Organization of Iran

    CERN Document Server

    Sohrabi, M

    1999-01-01

    Some highlights of new developments made in our laboratory at the Atomic Energy Organization of Iran on chemical and electrochemical etching (ECE) of polymer track detectors like polycarbonate (PC) are presented. They include introduction of new ECE chamber systems and methods for production of ECE signs and symbols, and a new versatile ECE chamber (VECE) system for multi-purpose, multi-size, and/or multi-shape detector processing; determination of photoneutron doses in and around high-energy X-ray beams of a 20 MV medical accelerator; verification of the Smythe and Mason equations for ECE of tracks in polymers; ECE of alpha and recoil tracks in PC using PMW, PEW and PEMW etchants; introduction of a novel method using ethylene diamine for treatment of PC detectors with its applications, for example in precision removal of surface layers of PC (e.g. bulk removal rates of about 0.04, 0.15, 0.36, 0.66, and 1.33 mm min sup - sup 1 for 60%, 65%, 70%, 75% and 80% ethylene diamine solution (v/v) in water respectivel...

  3. A study of commercially-available polyethylene terephthalate (PET) and polycarbonate as nuclear track detector materials

    Science.gov (United States)

    Espinosa, G.; Golzarri, J. I.; Vazquez-Lopez, C.; Trejo, R.; Lopez, K.; Rickards, J.

    2014-07-01

    In the study of the sensitivity of materials to be used as nuclear track detectors, it was found that commercial polyethylene terephthalate (PET) from Ciel® water bottles, commercial roof cover polycarbonate, and recycled packaging strips (recycled PET), can be used as nuclear track detectors. These three commercial materials present nuclear tracks when bombarded by 2.27 MeV nitrogen ions produced in a Pelletron particle accelerator, and by fission fragments from a 252Cf source (79.4 and 103.8 MeV), after a chemical etching with a 6.25M KOH solution, or with a 6.25M KOH solution with 20% methanol, both solutions at 60±1°C. As an example, the nitrogen ions deposit approximately 1 keV/nm in the form of ionization and excitation at the surface of PET, as calculated using the SRIM code. The fission fragments deposit up to 9 keV/nm at the surface, in both cases generating sufficient free radicals to initiate the track formation process. However, 5 MeV alpha particles, typical of radon (222Rn) emissions, deposit only 0.12 keV/nm, do not present tracks after the chemical etching process. This valuable information could be very useful for further studies of new materials in nuclear track methodology.

  4. Swift heavy ion induced modification in polycarbonate membrane for gas separation

    International Nuclear Information System (INIS)

    Rajesh Kumar; Prasad, Rajendra; Vijay, Y.K.; Das, D.

    2003-01-01

    Polymeric membranes are extensively used for commercial gas separation applications. Makrofol-KG (polycarbonate) is a glassy polymer. 40 μm thick sheet of Makrofol-KG was irradiated with 40 Ar (14.9 MeV/n) of fluence 10 3 ions/cm 2 and 20 μm thick sheet with 5.3 MeV α-particles of fluence 10 7 ions/cm 2 . The permeability of these polycarbonate membranes for H 2 and CO 2 was measured and also after etching in 6 N NaOH at 60 degC for different periods. Permeability is found to be increased with etching time. At a definite time, critical etching time, the permeability rapidly increases in PC. Positron annihilation lifetimes for unirradiated and irradiated membranes were measured with fast fast coincidence system to study the correlation of free volume hole concentration with gas separation properties. (author)

  5. Evaluation of different polymers for fast neutron personnel dosimetry using electrochemical etching

    International Nuclear Information System (INIS)

    Gammage, R.B.; Cotter, S.J.

    1977-01-01

    There is considerable optimism for the enhancement by electrochemical etching of fast neutron-induced recoil tracks in polycarbonate for the purpose of personnel dosimetry. The threshold energy, however, is rather high. A desirable improvement would be to lower this energy below 1 MeV. With this objective in mind, we have commenced an investigation of cellulose acetate, triacetate, and acetobutyrate in addition to polycarbonate. These cellulose derivatives are chemically more reactive and physically weaker than polycarbonate. It might, therefore, be possible to initiate the electrochemical amplification at the sites of shorter recoil atom damage tracks than is possible with polycarbonate. Some characteristics important for electrochemically etching in aqueous electrolytes are listed. Chemical etching is combined with treeing, an electrical breakdown process that starts when the dielectric strength is exceeded. These mechanical and electrical properties pertain to the dry plastics. The absorption of water molecules and electrolyte ions will cause these values to be reduced. Results and conclusions of the study are presented

  6. Thermodynamics of nuclear track chemical etching

    Science.gov (United States)

    Rana, Mukhtar Ahmed

    2018-05-01

    This is a brief paper with new and useful scientific information on nuclear track chemical etching. Nuclear track etching is described here by using basic concepts of thermodynamics. Enthalpy, entropy and free energy parameters are considered for the nuclear track etching. The free energy of etching is determined using etching experiments of fission fragment tracks in CR-39. Relationship between the free energy and the etching temperature is explored and is found to be approximately linear. The above relationship is discussed. A simple enthalpy-entropy model of chemical etching is presented. Experimental and computational results presented here are of fundamental interest in nuclear track detection methodology.

  7. Novel single-cell mega-size chambers for electrochemical etching of panorama position-sensitive polycarbonate ion image detectors

    Science.gov (United States)

    Sohrabi, Mehdi

    2017-11-01

    A novel development is made here by inventing panorama single-cell mega-size electrochemical etching (MS-ECE) chamber systems for processing panorama position-sensitive mega-size polycarbonate ion image detectors (MS-PCIDs) of potential for many neutron and ion detection applications in particular hydrogen ions or proton tracks and images detected for the first time in polycarbonates in this study. The MS-PCID is simply a large polycarbonate sheet of a desired size. The single-cell MS-ECE invented consists of two large equally sized transparent Plexiglas sheets as chamber walls holding a MS-PCID and the ECE chamber components tightly together. One wall has a large flat stainless steel electrode (dry cell) attached to it which is directly in contact with the MS-PCID and the other wall has a rod electrode with two holes to facilitate feeding and draining out the etching solution from the wet cell. A silicon rubber washer plays the role of the wet cell to hold the etchant and the electrical insulator to isolate the dry cell from the wet cell. A simple 50 Hz-HV home-made generator provides an adequate field strength through the two electrodes across the MS-ECE chamber. Two panorama single-cell MS-ECE chamber systems (circular and rectangular shapes) constructed were efficiently applied to processing the MS-PCIDs for 4π ion emission image detection of different gases in particular hydrogen ions or protons in a 3.5 kJ plasma focus device (PFD as uniquely observed by the unaided eyes). The panorama MS-PCID/MS-ECE image detection systems invented are novel with high potential for many applications in particular as applied to 4π panorama ion emission angular distribution image detection studies in PFD space, some results of which are presented and discussed.

  8. Design and development of wide energy neutron REM equivalent spectrometer-dosimeters based on polycarbonates and Cr-39

    International Nuclear Information System (INIS)

    Faermann, S.

    1985-03-01

    This work describes a system composed of a Rem response personnel neutron dosemeter, based on boron radiators and a polycarbonate track detector, for monitoring dose equivalents in the energy range 1 eV to 14 MeV, an electrochemical etching system for revealing damage sites in solid state track etch detectors, a reader for magnifying the etched pits and a microprocessor for evaluating the dose equivalents and their uncertainties. The performance and directional dependence of the dosemeter when exposed to monoenergetic and polyenergetic neutron fields in the epithermal and fast energy regions are discussed. Saturation effects in polycarbonate foils are presented and a comparison is made between the response of polycarbonate and CR-39 foils, used as passive detectors in the dosemeter. A new passive miniature fast neutron spectrometer-dosimeter is also described. The device is based on the detection of proton tracks by electrochemical etching of CR-39 foils covered with thin polyethylene layers of different thicknesses. By means of this device it is possible to assess the fast neutron energy spectrum in 10 energy intervals in the energy range 0.5-15 MeV. Dose equivalents can be determined in the dose equivalent range 20 mRem to 8 Rem, approximately (author)

  9. Effect of track etch rate on geometric track characteristics for polymeric track detectors

    International Nuclear Information System (INIS)

    Abdel-Naby, A.A.; El-Akkad, F.A.

    2001-01-01

    Analysis of the variable track etch rate on geometric track characteristic for polymeric track detectors has been applied to the case of LR-155 II SSNTD. Spectrometric characteristics of low energy alpha particles response by the polymeric detector have been obtained. The track etching kinematics theory of development of minor diameter of the etched tracks has been applied. The calculations show that, for this type of detector, the energy dependence of the minor track diameter d is linear for small-etched removal layer h. The energy resolution gets better for higher etched removal layer

  10. ECE laboratory in the Vinca Institute - its basic characteristics and fundamentals of electrochemical etching on polycarbonate

    International Nuclear Information System (INIS)

    Zunic, Z.S.; Ujic, P.; Celikovic, I.; Fujimoto, K.

    2003-01-01

    This paper deals with the introductory aspects of the Electrochemical Etching Laboratory installed at the VINCA Institute in the year 2003. The main purpose of the laboratory is its field application for radon and thoron large-scale survey using passive radon/thoron UFO type detectors. Since the etching techniques together with the laboratory equipment were transferred from the National Institute of Radiological Sciences, Chiba, Japan, it was necessary for both etching conditions to be confirmed and to be checked up, i. e., bulk etching speeds of chemical etching and electrochemical etching in the VINCA Electrochemical Etching Laboratory itself. Beside this initial step, other concerns were taken into consideration in this preliminary experimental phase such as the following: the measurable energy range of the polycarbonate film, background etch pit density of the film and its standard deviation and reproducibility of the response to alpha particles for different sets of etchings. (author)

  11. Etching conditions and shape of tracks

    International Nuclear Information System (INIS)

    Kudo, Shuichi

    1979-01-01

    The etching effect of hydrogen fluoride (HF) solution of 5%, 10%, 20% and 46% was investigated, using the perlite dug out at Wada-toge, Japan. They were studied by the progressive etching at 30 deg C, after the perlite was subjected to thermal neutron irradiation for 8 hours in the research reactor of the Institute for Atomic Energy of St. Paul (Rikkyo) University. Observation was performed mainly by replica, and false tracks, which are difficult to be judged whether they are the tracks or not, didn't appear as far as this experiment was concerned. Measurements of etch-pits and track density were carried out. The results of these investigations were considered and analyzed to describe them in five sections. The conclusions are as follows: (1) Regarding the ease of etch-pit observation and the adjustment of etching time, etching with 5% HF solution is most advantageous among four solutions of 5, 10, 20 and 46% HF. (2) The measurement of track density is more affected by the difference in counting criteria than the difference in etching conditions. The data on the size of etch-pits are required to discuss the problems of track density and counting efficiency. (3) If linear tracks are to be observed using hydrogen fluoride, it is necessary to investigate the etching characteristics with the solution of lower concentration. (Wakatsuki, Y.)

  12. Nuclear Track-Etched Pore Membrane Production Using OAEP's Research Reactor

    International Nuclear Information System (INIS)

    Chittrakarn, Thawat; Bhongsuwan, Tripob; Wanichapichart, Pikul; Nuanuin, Paiboon; Chongkum, Somporn; Khonduangkaew, Areerat; Bordeepong, Sunaree

    2003-10-01

    Result of this study shows that the OAEP's nuclear research reactor is a good source of both fast and thermal neutrons for pore piercing process on polycarbonate thin film. With our experimental design, the fast neutron provides better results in pore piercing comparing with thermal neutron bombardment. This can be explained that most of the latent tracks that occur by thermal neutron bombardment do not piercing through the thin film. Chemical etching process using NaOH solution with an appropriated time, concentration and temperature was employed to enlarge the latent tracks in the bombarded film by fast neutrons. Fast neutron bombardment with 5, 10 and 20 minutes bombarding time successfully produces the nuclear track membrane. Pore size and pore density of the produced membranes examined by SEM were 0.24-1.01 μm and 4.67 - 245 x 10 6 pore/cm 2 , respectively. Bubble point test showed the maximum pore diameter of the produced membrane ranged between 1.18 - 3.25 μm. Water permeability was studied and compared between the produced and commercial membranes

  13. Energy dependence of fast neutron dosimetry using electrochemical etching

    International Nuclear Information System (INIS)

    Su, S.J.; Morgan, K.Z.

    1978-01-01

    Registration of fast-neutron induced recoil tracks by the electrochemical etching technique as applied to sensitive Lexan polycarbonate foils provides a simple and inexpensive means of fast neutron personnel dosimetry. The sensitivity (tracks/neutron) of recoil particle registration is given as a function of neutron energy. Neutrons of 7 Li (p,n) 7 Be, 3 T (d,n) 4 He and 9 B, respectively. Results are compared with other studies using other neutron sources and conventional etching method

  14. A novel track density measurement method by thermal neutron activation of DYECETs

    International Nuclear Information System (INIS)

    Sohrabi, M.; Mahdi, Sh.

    1995-01-01

    A novel track density evaluation method based on thermal neutron activation of some elements of dyed electrochemically etched tracks (DYECETs) of charged particles in detectors like polycarbonate (PC) followed by measurements of gamma activity of the activated detectors is introduced. In this method, the tracks of charged particles like fast neutron-induced recoils in PC detectors were electrochemically etched, dyed by ''QuicDYECET'' methods as recently introduced by us, activated by thermal neutrons and counted for gamma activity determination to be correlated with track density. The activities of elements such as bromine-82 ( 82 Br) and sodium-24 ( 24 Na) on dyes such as Eosin Yellowish, Eosin Bluish, etc. determined by a hyper-pure germanium detector, were found to be in good correlation with DYECET density and thus particle fluence or dose. The effects of different types of dyes and their elements, dye concentration, neutron fluences and ECE durations on the DYECET density responses were studied. This new development is a method of scientific interest, potentially possessing some interesting features, as an alternative method for ECE track density determination using a gamma activity measuring system. It also has the drawback of being applicable only in centres having thermal neutron facilities. The results of the above studies are presented and discussed. (Author)

  15. Optimization of some electrochemical etching parameters for cellulose derivatives

    International Nuclear Information System (INIS)

    Chowdhury, Annis; Gammage, R.B.

    1978-01-01

    Electrochemical etching of fast neutron induced recoil particle tracks in cellulose derivatives and other polymers provides an inexpensive and sensitive means of fast neutron personnel dosimetry. A study of the shape, clarity, and size of the tracks in Transilwrap polycarbonate indicated that the optimum normality of the potassium hydroxide etching solution is 9 N. Optimizations have also been attempted for cellulose nitrate, triacetate, and acetobutyrate with respect to such electrochemical etching parameters as frequency, voltage gradient, and concentration of the etching solution. The measurement of differential leakage currents between the undamaged and the neutron damaged foils aided in the selection of optimum frequencies. (author)

  16. Ion track etching revisited: II. Electronic properties of aged tracks in polymers

    Science.gov (United States)

    Fink, D.; Muñoz Hernández, G.; Cruz, S. A.; Garcia-Arellano, H.; Vacik, J.; Hnatowicz, V.; Kiv, A.; Alfonta, L.

    2018-02-01

    We compile here electronic ion track etching effects, such as capacitive-type currents, current spike emission, phase shift, rectification and background currents that eventually emerge upon application of sinusoidal alternating voltages across thin, aged swift heavy ion-irradiated polymer foils during etching. Both capacitive-type currents and current spike emission occur as long as obstacles still prevent a smooth continuous charge carrier passage across the foils. In the case of sufficiently high applied electric fields, these obstacles are overcome by spike emission. These effects vanish upon etchant breakthrough. Subsequent transmitted currents are usually of Ohmic type, but shortly after breakthrough (during the track' core etching) often still exhibit deviations such as strong positive phase shifts. They stem from very slow charge carrier mobility across the etched ion tracks due to retarding trapping/detrapping processes. Upon etching the track's penumbra, one occasionally observes a split-up into two transmitted current components, one with positive and another one with negative phase shifts. Usually, these phase shifts vanish when bulk etching starts. Current rectification upon track etching is a very frequent phenomenon. Rectification uses to inverse when core etching ends and penumbra etching begins. When the latter ends, rectification largely vanishes. Occasionally, some residual rectification remains which we attribute to the aged polymeric bulk itself. Last not least, we still consider background currents which often emerge transiently during track etching. We could assign them clearly to differences in the electrochemical potential of the liquids on both sides of the etched polymer foils. Transient relaxation effects during the track etching cause their eventually chaotic behaviour.

  17. Development and application of the electrochemical etching technique. Annual progress report

    International Nuclear Information System (INIS)

    1979-08-01

    This report documents advances in the development and application of the electrochemical etching technique for thermal and epithermal neutron dosimetry as well as track geometry determinations. The bulk and track etching rates were studied by evaluating the track geometry during electrochemical etching. The foil surface removed versus etching time for two different etchants at 1000 V, 2 kHz, and 22 0 C were studied. Results indicated that the bulk etching rates were constant for the two etchants, i.e. 45% KOH and 45% KOH mixed with an equal volume of C 2 H 5 OH 5 and were equal to 0.20 +- 0.14 μm/hr and 2.7 +- 0.27 μm/hr from each side of the foil. The track etching rate (as contrasted with the bulk etching rate) can be determined by the microscope focus at various depths. The increase of track depth values as a function of etching time for the two etchants are plotted. The track cone angles were determined and found to be much larger for electrochemically etched polycarbonate foils than for most plastics etched with passive chemical techniques

  18. ECE laboratory in the Vinča institute: Its basic characteristics and fundamentals of electrochemic etching on polycarbonate

    Directory of Open Access Journals (Sweden)

    Žunić Zora S.

    2003-01-01

    Full Text Available This paper deals with the introductory aspects of the Electrochemical Etching Laboratory installed at the VINČA Institute in the year 2003. The main purpose of the laboratory is its field application for radon and thoron large-scale survey using passive radon/thoron UFO type detectors. Since the etching techniques together with the laboratory equipment were transferred from the National Institute of Radiological Sciences, Chiba, Japan, it was necessary for both etching conditions to be confirmed and to be checked up^ i. e., bulk etching speeds of chemical etching and electrochemical etching in the VINCA Electrochemical Etching Laboratory itself. Beside this initial step, other concerns were taken into consideration in this preliminary experimental phase such as the following: the measurable energy range of the polycarbonate film, background etch pit density of the film and its standard deviation and reproducibility of the response to alpha particles for different sets of etchings.

  19. Development and application of the electrochemical etching technique

    International Nuclear Information System (INIS)

    Sanders, M.E.

    1984-07-01

    This report documents the advances achieved in the development and application of several etched damage track plastic dosimeters that can be used to measure dose-equivalent from neutrons with energies from thermal to 20 MeV. The project was initiated with the design of a rem-responding dosimeter that measured fast (> 1 MeV) neutron dose-equivalent as a function of the damage track density directly induced within the volume of polycarbonate foils amplified by electrochemical etching. Stillwagon (1978) adapted electrochemical etching of polycarbonate foils (ECEPF) to alpha dosimetry and used the technique to determine Pu-239 uptake in human bone. Su (1979) extended the usefulness of the ECEPF neutron dosimetry technique to encompass thermal neutron dose measurement. The thermal neutron dosimeter was composed of an external radiator tablet made of 7 LiF in contact with a polycarbonate foil and utilized the thermal neutron-induced 6 Li(n, α) 3 H reaction to give a dose-equivalent response as a function of alpha track density registered in the detector foil. An intermediate (1 eV-1 MeV) neutron dosimeter was developed and has been shown to give an approximately dose-equivalent response to neutrons with energies from 1 eV to 17 MeV. The intermediate neutron dosimeter consists of 6 LiF-Teflon/CR-39 Polymer foil assembly which is enclosed by a (Cd + In) neutron filter. The neutron dose-equivalent is measured as a variable function of the damage track density registered in the CR-39 detector foil due to alpha particles from the 1/v dependent 6 Li(n, α) 3 H reaction, recoil H, C, O nuclei from neutron-induced elastic scattering within the foil volume, and protons from the 6 Li(n, p) reaction for neutron energies above 2 MeV. 46 figs., 6 tabs

  20. Ion track etching revisited: I. Correlations between track parameters in aged polymers

    Science.gov (United States)

    Fink, D.; Muñoz H., G.; García A., H.; Vacik, J.; Hnatowicz, V.; Kiv, A.; Alfonta, L.

    2018-04-01

    Some yet poorly understood problems of etching of pristine and swift heavy ion track-irradiated aged polymers were treated, by applying conductometry across the irradiated foils during etching. The onset times of etchant penetration across pristine foils, and the onset times of the different etched track regimes in irradiated foils were determined for polymers of various proveniences, fluences and ages, as well as their corresponding etching speeds. From the results, correlations of the parameters with each other were deduced. The normalization of these parameters enables one to compare irradiated polymer foils of different origin and treatment with one another. In a number of cases, also polymeric gel formation and swelling occur which influence the track etching behaviour. The polymer degradation during aging influences the track etching parameters, which differ from each other on both sides of the foils. With increasing sample age, these differences increase.

  1. A new dyed ECE track identification method for nuclear particle detection

    International Nuclear Information System (INIS)

    Sohrabi, M.; Bojd, S.S.

    1990-01-01

    A new procedure for obtaining highly contrasted red-dyed electrochemically etched recoil tracks in polymers such as polycarbonate (PC) and CR-39 has been successfully developed for spectrophotometry as applied to neutron dosimetry. The principal rationale in this method has been the provision of highly contrasted, photon-absorbing, large, dyed recoil tracks in an unaffected bulk material. The method consists of: (a) exposing the polymer to charged particles or neutrons; (b) electrochemical etching of the tracks; (c) acid sensitization; (d) dyeing with an appropriate dye. By investigation of the type, concentration, duration and temperature of the acid and the dye, optimized values of 20% by weight acrylic acid at 75 0 C for 3.5 h for sensitization, and 3% by weight eosin bluish dye at 95 0 C for 4 h for dyeing, provided a nearly 100% dyed-track efficiency. Spectrophotometry by UV and infrared radiation track counting, and optical densitometry were applied to the dyed samples. The results have shown some promise for UV absorbance measurements in routine large-scale applications. In this paper, the results of optimization studies and preliminary application of the technique to neutron dosimetry are presented and discussed. (author)

  2. Automatic spark counting of alpha-tracks in plastic foils

    International Nuclear Information System (INIS)

    Somogyi, G.; Medveczky, L.; Hunyadi, I.; Nyako, B.

    1976-01-01

    The possibility of alpha-track counting by jumping spark counter in cellulose acetate and polycarbonate nuclear track detectors was studied. A theoretical treatment is presented which predicts the optimum residual thickness of the etched foils in which completely through-etched tracks (i.e. holes) can be obtained for alpha-particles of various energies and angles of incidence. In agreement with the theoretical prediction it is shown that a successful spark counting of alpha-tracks can be performed even in polycarbonate foils. Some counting characteristics, such as counting efficiency vs particle energy at various etched foil thicknesses, surface spark density produced by electric breakdowns in unexposed foils vs foil thickness, etc. have been determined. Special attention was given to the spark counting of alpha-tracks entering thin detectors at right angle. The applicability of the spark counting technique is demonstrated in angular distribution measurements of the 27 Al(p,α 0 ) 24 Mg nuclear reaction at Ep = 1899 keV resonance energy. For this study 15 μm thick Makrofol-G foils and a jumping spark counter of improved construction were used. (orig.) [de

  3. Application of image analyzer for radon concentration measurement by nuclear track detector

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Vukovic, J.; Novakovic, V.; Tasic, M.

    1998-01-01

    Radon concentration measurements were performed by determination of alpha tracks density in NTD of polymer type (Allyl diglycol polycarbonate - ADC Intercast EC, Parma). NTD plates were exposed to Rn, during 72 days in low level laboratory (LLL) at the Institute of Physics, Belgrade. Therefore, they were etched in 6N - NaOH water solution during 8 h at bath temperature of 70 0 C. The analyses of the alpha tracks was made by optical microscope and semiquantitative image analyzer using video camera digitizer attached to Pentium PC with software Ozaria V2.5. According to the determined mean track density value, ρmean=74210 tracks/cm 2 (background track density ρb=123 tracks/cm 2 ) Rn concentration was calculated to be 1174 Bq/m 3 . Obtained higher value than global - normal indoor Rn concentration might be the consequence of the temperature difference in LLL and outdoor. (author)

  4. LLL development of a combined etch track: albedo dosimeter

    International Nuclear Information System (INIS)

    Griffith, R.V.; Fisher, J.C.; Harder, C.A.

    1977-01-01

    The addition of polycarbonate sheet to albedo detectors for electrochemical etching provides a simple, inexpensive way to reduce the spectral sensitivity of the personnel dosimeter without losing the albedo features of sensitivity and ease of automation. The ECEP technique also provides the dosimetrist with the potential for identifying conditions of body orientation that might otherwise lead to significant error in dosimeter evaluation

  5. Measurement of low neutron fluences with polycarbonate foils electrochemically etched with methyl alcohol-KOH solution

    International Nuclear Information System (INIS)

    Kumamoto, Y.

    1982-01-01

    Electrochemical etching of polycarbonate foils was performed using a KOH solution with a high concentration of methyl alcohol under different conditions of field strength, frequency, temperature and etching time. These studies showed that the highest neutron sensitivity relative to the inherent background in the foil was obtained under the following etching conditions: 52 kV/cm, 1 kHz, 30 0 C, 30 min in a solution of 45 gm KOH + 80 cc CH 3 OH + 20 cc H 2 O. Under these conditions, 100 mrem of neutrons from a Ra-Be source gave 70 pits per cm 2 while background was 7 +- 3 pits per cm 2 (10 +- 5 mrem). The pit diameters were about 90 μm. This sensitivity (giving lowest measurable dose of 15 mrem) is quite sufficient for personnel neutron dosimetry applications and the size of the pits is large enough for easy counting using a microscope at magnification of 40X. (author)

  6. A new parameter in the electrochemical etching of polymer track detectors

    International Nuclear Information System (INIS)

    Sohrabi, M.; Katouzi, M.

    1993-01-01

    It was discovered that the pressure applied to the electrochemical etching (ECE) chamber system and in turn to washers holding the detector tight in place between two semi-chambers has a direct effect on the internal heating and time to breakdown of the polymer detector. The effect was found to be dependent on the type, material, shape and size of the washers holding the detector in place under pressure. To verify such parameters, a pressure ECE chamber (PECE) with measurable and reproducible pressure was designed and constructed. Three types of rubber washers, such as ''O'' rings, flat rings and sheets as well as polycarbonate (PC) detectors glued directly between two semi-syringes, were used. Flat rubber sheets were shown to have relatively minor effects on the internal heating rate and are recommended. The effect seems to be due to forced vibrations of the detector under an electric field, the frequency of which depends on the degree to which the detector is stretched under pressure, like winding the strings of a musical instrument. The results of the above studies are presented and discussed. (orig.)

  7. Surfactant-enhanced control of track-etch pore morphology

    International Nuclear Information System (INIS)

    Apel', P.Yu.; Blonskaya, I.V.; Didyk, A.Yu.; Dmitriev, S.N.; Orelovich, O.L.; Samojlova, L.I.; Vutsadakis, V.A.; Root, D.

    2000-01-01

    The influence of surfactants on the process of chemical development of ion tracks in polymers is studied. Based on the experimental data, a mechanism of the surfactant effect on the track-etch pore morphology is proposed. In the beginning of etching the surfactant is adsorbed on the surface and creates a layer that is quasi-solid and partially protects the surface from the etching agent. However, some etchant molecules diffuse through the barrier and react with the polymer surface. This results in the formation of a small hole at the entrance to the ion track. After the hole has attained a few annometers in diameter, the surfactant molecules penetrate into the track and cover its walls. Further diffusion of the surfactant into the growing pore is hindered. The adsorbed surfactant layer is not permeable for large molecules. In contrast, small alkali molecules and water molecules diffuse into the track and provide the etching process enlarging the pore. At this stage the transport of the surfactant into the pore channel can proceed only due to the lateral diffusion in the adsorbed layer. The volume inside the pore is free of surfactant molecules and grows at a higher rate than pore entrance. After a more prolonged etching the bottle-like (or 'cigar-like') pore channels are formed. The bottle-like shape of the pore channels depends on the etching conditions such as alkali and surfactant concentration, temperature, and type of the surfactant. The use of surfactants enables one to produce track-etch membranes with improved flow rate characteristics compared with those having cylindrical pores with the same nominal pore diameters

  8. Future developments in etched track detectors for neutron dosimetry

    International Nuclear Information System (INIS)

    Tommasino, L.

    1987-01-01

    Many laboratories engaged in the field of personal neutron dosimetry are interested in developing better etching processes and improving the CR-39 detecting materials. To know how much effort must still be devoted to the development of etch track dosimetry, it is necessary to understand the advantages. limitations and degree of exploitation of the currently available techniques. So much has been learned about the chemical and electrochemical etching processes that an optimised combination of etching processes could make possible the elimination of many of the existing shortcomings. Limitations of etched track detectors for neutron dosimetry arise mainly because the registration occurs only on the detector surface. These damage type detectors are based on radiation induced chain scission processes in polymers, which result in hole-type tracks in solids. The converse approach, yet to be discovered, would be the development of cure-track detectors, where radiation induced cross linking between organic polymer chains could result in solid tracks in liquids. (author)

  9. Naturally etched tracks in apatites and the correction of fission track dating

    CERN Document Server

    Tien, J L

    1999-01-01

    Naturally etched tracks have been found in apatites from the rapid cooled, high-level Kunon pluton in the Zhangzhou Igneous Complex, SE China. This is manifested by the fact that the apatite fission track (FT) age derived from conventional counting of spontaneous and induced tracks yields a result of 140.6+-6.5 Ma, which is much older than the ages determined using other methods on different minerals from the same rock. When tracks are observed after etching the polished inner sections of the apatite grains, the naturally etched tracks characterized by having hazy boundaries can be distinguished from the normal tracks with sharp boundaries. The age obtained by omitting these fading-resistant hazy tracks, 76.5+-4.0 Ma, indicates the time of the Kunon pluton cooling down to approx 100 deg. C. The corrected peak age (73.8 Ma) is consistent with the other apatite FT peak ages (79.2 to 70.2 Ma) of the nearly contemporaneous plutons in the same igneous complex.

  10. On the detection of low-energy 4He, 12C, 14N, 16O ions in PC foils and its use in nuclear reaction measurements

    International Nuclear Information System (INIS)

    Somogyi, G.; Hunyadi, I.; Koltay, E.; Zolnai, L.

    1977-01-01

    It is shown that by using a proper etching reagent the registration sensitivity of polycarbonate foils can be enhanced and they prove to be very suitable track recorders for alpha-particles emitted from nuclear reactions. At 6 MeV an energy resolution of 0.2 MeV can be achieved when using the track diameters as a measure of the particle energy. A theoretical way to calculate the track parameters important in nuclear reaction measurements involving alpha-particles recorded in polycarbonate foils is given. For this purpose the track etch rate vs residual range curve was determined by a parameter optimization procedure. The energy resolution of the track-diameter method as a function of the particle energy was predicted. In earlier studies the track-diameter method was mostly used in angular distribution measurements of (d, α) nuclear reactions. In this work it is shown that with polycarbonate foils it can be well applied to excitation function measurements, as well. Such studies are presented for the α 0 and α 1 groups of the 27 Al(p, α) 24 Mg reaction in an energy interval between 1540 and 1920 keV. Finally, preliminary results of the track etching properties of low-energy O + , N + , C + and He + ions accelerated with a 5 MV Van de Graaff generator are given. (Auth.)

  11. Gamma radiation effect study in polycarbonate optical and mechanics properties

    International Nuclear Information System (INIS)

    Araujo, E.S. de.

    1991-02-01

    Polycarbonates (PC) are used in different industrial applications due to their excellent dielectric characteristics, impact resistance, and high temperature resistance. In some of these applications, the polycarbonates are exposed to gamma radiation which produces molecular scissions, causing changes in the polycarbonate properties. To estimate the radiation effects in the Durolon polycarbonate, samples were irradiated with 60 Co gamma rays with doses between 0,2 kGy and 300 kGy. The results obtained showed that the PC mechanical properties are not changed due to the gamma radiation. However the results showed an expressive variation in the yellowness index for doses above 1 kGy. The results showed that it is possible to use the gamma sterilization of PC in applications where the coloration of PC is not critical. (author). 21 refs, 25 figs, 3 tabs

  12. Liquid nitrogen enhancement of alpha particle tracks in a polycarbonate detector

    International Nuclear Information System (INIS)

    Pilione, L.J.

    1977-01-01

    Makrofol-E polycarbonate detectors were exposed to 1 to 3 MeV alpha particles and subsequently immersed in liquid nitrogen for various periods of time. The influence of the liquid nitrogen on the track recording properties of the detector has been found by measuring the track densities and diameters. Track densities increase with immersion time with a maximum gain of approximately 9% after 1200 min in liquid nitrogen. Track enhancement decreases with waiting time between the end of alpha particle exposure and the beginning of liquid nitrogen immersion. Track diameters decrease with time after passage of the particles and this process is accelerated by immersion in liquid nitrogen. (author)

  13. Evolution of nanodot morphology on polycarbonate (PC) surfaces by 40 keV Ar"+

    International Nuclear Information System (INIS)

    Goyal, Meetika; Chawla, Mahak; Gupta, Divya; Shekhawat, Nidhi; Sharma, Annu; Aggarwal, Sanjeev

    2016-01-01

    In the present paper we have discussed the effect of 40 keV Ar"+ ions irradiation on nanoscale surface morphology of Polycarbonate (PC) substrate. Specimens were sputtered at off normal incidences of 30°, 40° and 50° with the fluence of 1 × 10"1"6 Ar"+cm"−"2. The topographical behaviour of specimens was studied by using Atomic Force Microscopy (AFM) technique. AFM study demonstrates the evolution of nano dot morphology on PC specimens on irradiating with 1 × 10"1"6 Ar"+cm"−"2. Average size of dots varied from 37-95 nm in this specified range of incidence while density of dots varied from 0.17-3.0 × 107 dotscm"−"2. Such variations in morphological features have been supported by estimation of ion range and sputtering yield through SRIM simulations.

  14. Study of the characteristics of ionizing particles record of CR-39 track detectors

    International Nuclear Information System (INIS)

    Brandao, Luis Eduardo Barreira

    1983-01-01

    The bulk and track etching proprieties of a new Solid State Nuclear Track Detector CR-39 were investigated under different etching conditions. The discussion is based on results obtained using aqueous solutions of KOH with addition of alcoholic solvent to aqueous solutions. It was found that track registration sensitivity can be dramatically changed by using the proper chemical treatment. A method to enlarge and dye etch tracks to be viewed by simple projection on a screen is discussed. The applications of CR-39 in neutron fluence measurements are shown. Graphs are presented of the densities of the registered traces by the detector as a function of etch time both for samples with and without a polycarbonate radiator. (author)

  15. Studies on the characteristics of nuclear track spark counting for neutron monitoring

    International Nuclear Information System (INIS)

    Kawai, H.; Koga, T.; Morishima, H.; Niwa, T.; Nishiwaki, Y.

    1979-01-01

    The fission-track counting method using polycarbonate foil is known to be very effective for neutron monitoring. The detection system consists of a track detector foil placed in contact with a thin layer of fissile material. When the unit is irradiated with neutrons, fission fragments from the fissile material produce tracks in the foil. The foil is then etched chemically to enlarge the tracks to etch-pits, which are counted by an automatic spark counting method suggested by Cross and Tommasino. Spark counting characteristics of the above system using polycarbonate detector foils of different thicknesses and aluminized polyester sheets having different thicknesses of the aluminium which serves as an electrode, and etch-pit sizes in relation to spark counting have been studied. The results obtained are summarized as follows: 1. A growth in etch-pit sizes was observed for etching times of 10 to 50 minutes with Makrofol KG (10 μm thick) and Panlite foils (18 μm thick). As the etching time increased, the number of etch-pits which appeared as round pits increased and the number which appeared rod-like decreased; 2. Round etch-pits seemed to be easily spark-punched; 3. Major and minor diameters of etch-pits produced by fission fragments from the uranium fissile target were larger than those from the thorium target; 4. As the thickness of the Makrofol KG foil increased, the minor diameters of the etch-pits appeared to become smaller and major diameters larger; 5. The foils that appeared to be best suited for routine use were 10 μm thick Makrofol KG or 6 μm thick Lumirror foils. (author)

  16. Current problems in chemical track etching

    International Nuclear Information System (INIS)

    Somogyi, G.

    1984-01-01

    A schematic survey is given on the current relevant problems of the etching (or revelation) of multi-track and single-track events in dielectric solids. Some aspects of the research trends and possible new applications of the effects observable here, are also considered. (author)

  17. Response of MG63 osteoblast-like cells onto polycarbonate membrane surfaces with different micropore sizes.

    Science.gov (United States)

    Lee, Sang Jin; Choi, Jin San; Park, Ki Suk; Khang, Gilson; Lee, Young Moo; Lee, Hai Bang

    2004-08-01

    Response of different types of cells on materials is important for the applications of tissue engineering and regenerative medicine. It is recognized that the behavior of the cell adhesion, proliferation, and differentiation on materials depends largely on surface characteristics such as wettability, chemistry, charge, rigidity, and roughness. In this study, we examined the behavior of MG63 osteoblast-like cells cultured on a polycarbonate (PC) membrane surfaces with different micropore sizes (0.2-8.0 microm in diameter). Cell adhesion and proliferation to the PC membrane surfaces were determined by cell counting and MTT assay. The effect of surface micropore on the MG63 cells was evaluated by cell morphology, protein content, and alkaline phosphatase (ALP) specific activity. It seems that the cell adhesion and proliferation were progressively inhibited as the PC membranes had micropores with increasing size, probably due to surface discontinuities produced by track-etched pores. Increasing micropore size of the PC membrane results in improved protein synthesis and ALP specific activity in isolated cells. There was a statistically significant difference (Pmicropore sizes. The MG63 cells also maintained their phenotype under conditions that support a round cell shape. RT-PCR analysis further confirmed the osteogenic phenotype of the MG63 cells onto the PC membranes with different micropore sizes. In results, as micropore size is getting larger, cell number is reduced and cell differentiation and matrix production is increased. This study demonstrated that the surface topography plays an important role for phenotypic expression of the MG63 osteoblast-like cells.

  18. Preparation of Track Etch Membrane Filters Using Polystyrene Film

    International Nuclear Information System (INIS)

    Kaewsaenee, Jerawut; Ratanatongchai, Wichian; Supaphol, Pitt; Visal-athaphand, Pinpan

    2007-08-01

    Full text: Polystyrene nuclear track etch membrane filters was prepared by exposed 13 .m thin film polystyrene with fission fragment. Nuclear latent track was enlarged to through hole on the film by etching with 80 o C 40% H 2 SO 4 with K 2 Cr 2 O 7 solution for 6-10 hour. The hole size was depend on concentration of etching solution and etching time with 1.3-3.4 .m hole diameter. The flow rate test of water was 0.79-1.56 mm cm-2 min-1 at 109.8-113.7 kPa pressure

  19. Etched track radiometers in radon measurements: a review

    CERN Document Server

    Nikolaev, V A

    1999-01-01

    Passive radon radiometers, based on alpha particle etched track detectors, are very attractive for the assessment of radon exposure. The present review considers various devices used for measurement of the volume activity of radon isotopes and their daughters and determination of equilibrium coefficients. Such devices can be classified into 8 groups: (i) open or 'bare' detectors, (ii) open chambers, (iii) sup 2 sup 2 sup 2 Rn chambers with an inlet filter, (iv) advanced sup 2 sup 2 sup 2 Rn radiometers, (v) multipurpose radiometers, (vi) radiometers based on a combination of etched track detectors and an electrostatic field, (vii) radiometers based on etched track detectors and activated charcoal and (viii) devices for the measurement of radon isotopes and/or radon daughters by means of track parameter measurements. Some of them such as the open detector and the chamber with an inlet filter have a variety of modifications and are applied widely both in geophysical research and radon dosimetric surveys. At the...

  20. Bulk and track etching of PET studied by spectrophotometer

    International Nuclear Information System (INIS)

    Zhu, Z.Y.; Duan, J.L.; Maekawa, Y.; Koshikawa, H.; Yoshida, M.

    2004-01-01

    UV-VIS spectra of poly(ethylene terephthalate) (PET) solutions formed by etching PET in NaOH solution were analyzed with respect to the etching time. A linear relationship between absorptions centered at 4.45 and 5.11 eV with weight loss of PET in NaOH solution was established. The relation was applied to study the influence of UV light illumination on bulk etching of PET and to evaluate pore size of etched-through tracks. It is found that bulk etching of PET can be greatly enhanced by UV illumination in air in the wavelength range around 313 nm. A surface area of about 350 nm in thickness shows a 23 times increase in bulk-etching rate after illuminated for 6 h. The phenomenon is attributed to the oxygen-assisted photo-degradation through generating of new photo-unstable species. The enhancement in bulk etching was immediately reduced as the etching proceeds below the surface with an exponential decay constant of about 1.5 μm -1 . Etching of Xe ion irradiated PET films gives extra etching products with similar chemical structure as revealed by spectrophotometer measurements. Quantitative analysis of etching products from latent tracks implies that pores of about 14.6 nm in radius are formed after etching in 0.74 N NaOH at 40 deg. C for 35 min, which is in agreement with the conductometric measurement

  1. Bulletin of Materials Science | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    Polymer blends of polycarbonate (PC) and polysulphone (PSF) having thickness, 27 m, are prepared by solution cast method. The transport properties of pores in a blend membrane are examined. The pores were produced in this membrane by a track etching technique. For this purpose, a thin polymer membrane was ...

  2. Photodegradation and stability of bisphenol a polycarbonate in weathering conditions

    NARCIS (Netherlands)

    Diepens, M.

    2009-01-01

    Polycarbonates, and especially bisphenol A polycarbonate (BPA-PC), are used in many fields of applications due to their excellent physical and mechanical properties, such as high impact resistance, ductility, and transparency. One major drawback of using polycarbonates in outdoor applications is

  3. Nuclear track evolution by capillary condensation during etching in SSNT detectors

    International Nuclear Information System (INIS)

    Martín-Landrove, R.; Sajo-Bohus, L.; Palacios, D.

    2013-01-01

    The microscopic process taking place during chemical etching is described in terms of a dynamic framework governed by capillary condensation. The aim is to obtain physical information on how the cone shaped tracks with curved walls evolve during chemical etching under a close examination of first principles. The results obtained with the proposed theory are compared with published values to establish their range of validity. - Highlights: ► Capillary condensation seems to play a role at early etched track evolution. ► The etched track shape and the first principles behind it are easily related. ► In spite of its simplicity, theory was able to pass stringent experimental tests. ► Theory results have a simple analytical form which includes etch induction time

  4. Determination of nuclear tracks parameters on sequentially etched PADC detectors

    Science.gov (United States)

    Horwacik, Tomasz; Bilski, Pawel; Koerner, Christine; Facius, Rainer; Berger, Thomas; Nowak, Tomasz; Reitz, Guenther; Olko, Pawel

    Polyallyl Diglycol Carbonate (PADC) detectors find many applications in radiation protection. One of them is the cosmic radiation dosimetry, where PADC detectors measure the linear energy transfer (LET) spectra of charged particles (from protons to heavy ions), supplementing TLD detectors in the role of passive dosemeter. Calibration exposures to ions of known LET are required to establish a relation between parameters of track observed on the detector and LET of particle creating this track. PADC TASTRAK nuclear track detectors were exposed to 12 C and 56 Fe ions of LET in H2 O between 10 and 544 keV/µm. The exposures took place at the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan in the frame of the HIMAC research project "Space Radiation Dosimetry-Ground Based Verification of the MATROSHKA Facility" (20P-240). Detectors were etched in water solution of NaOH with three different temperatures and for various etching times to observe the appearance of etched tracks, the evolution of their parameters and the stability of the etching process. The applied etching times (and the solution's concentrations and temperatures) were: 48, 72, 96, 120 hours (6.25 N NaOH, 50 O C), 20, 40, 60, 80 hours (6.25 N NaOH, 60 O C) and 8, 12, 16, 20 hours (7N NaOH, 70 O C). The analysis of the detectors involved planimetric (2D) measurements of tracks' entrance ellipses and mechanical measurements of bulk layer thickness. Further track parameters, like angle of incidence, track length and etch rate ratio were then calculated. For certain tracks, results of planimetric measurements and calculations were also compared with results of optical track profile (3D) measurements, where not only the track's entrance ellipse but also the location of the track's tip could be directly measured. All these measurements have been performed with the 2D/3D measurement system at DLR. The collected data allow to create sets of V(LET in H2 O) calibration curves suitable for short, intermediate and

  5. Application of a cellular automaton for the evolution of etched nuclear tracks

    International Nuclear Information System (INIS)

    Cruz-Trujillo, Leonardo de la; Hernández-Hernández, C.; Vázquez-López, C.; Zendejas-Leal, B.E.; Golzarri, I.; Espinosa, G.

    2013-01-01

    In the present work, it is demonstrated the first application of cellular automata to the growing of etched nuclear tracks. The simplest case in which conical etched tracks are gradually formed is presented, as well as a general case of time varying etching rate V t . It is demonstrated that the cellular automata elements consist in an image pattern of the latent nuclear track input cells, 16 rules for updating states, the Moore neighborhood and an algorithm of four states. - Highlights: ► We model the evolution of an etched nuclear track using cellular automata (ca). ► A cellular automaton of a conical track has 4 states and 16 transition rules. ► The ca of general tracks require a not regular mesh and the L(t) and V b parameters

  6. Model of wet chemical etching of swift heavy ions tracks

    Science.gov (United States)

    Gorbunov, S. A.; Malakhov, A. I.; Rymzhanov, R. A.; Volkov, A. E.

    2017-10-01

    A model of wet chemical etching of tracks of swift heavy ions (SHI) decelerated in solids in the electronic stopping regime is presented. This model takes into account both possible etching modes: etching controlled by diffusion of etchant molecules to the etching front, and etching controlled by the rate of a reaction of an etchant with a material. Olivine ((Mg0.88Fe0.12)2SiO4) crystals were chosen as a system for modeling. Two mechanisms of chemical activation of olivine around the SHI trajectory are considered. The first mechanism is activation stimulated by structural transformations in a nanometric track core, while the second one results from neutralization of metallic atoms by generated electrons spreading over micrometric distances. Monte-Carlo simulations (TREKIS code) form the basis for the description of excitations of the electronic subsystem and the lattice of olivine in an SHI track at times up to 100 fs after the projectile passage. Molecular dynamics supplies the initial conditions for modeling of lattice relaxation for longer times. These simulations enable us to estimate the effects of the chemical activation of olivine governed by both mechanisms. The developed model was applied to describe chemical activation and the etching kinetics of tracks of Au 2.1 GeV ions in olivine. The estimated lengthwise etching rate (38 µm · h-1) is in reasonable agreement with that detected in the experiments (24 µm · h-1).

  7. Evolution of nanodot morphology on polycarbonate (PC) surfaces by 40 keV Ar{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, Meetika, E-mail: meetika89@gmail.com; Chawla, Mahak; Gupta, Divya; Shekhawat, Nidhi; Sharma, Annu; Aggarwal, Sanjeev [Department of Physics, Kurukshetra University, Kurukshetra - 136119 (India)

    2016-05-06

    In the present paper we have discussed the effect of 40 keV Ar{sup +} ions irradiation on nanoscale surface morphology of Polycarbonate (PC) substrate. Specimens were sputtered at off normal incidences of 30°, 40° and 50° with the fluence of 1 × 10{sup 16} Ar{sup +}cm{sup −2}. The topographical behaviour of specimens was studied by using Atomic Force Microscopy (AFM) technique. AFM study demonstrates the evolution of nano dot morphology on PC specimens on irradiating with 1 × 10{sup 16} Ar{sup +}cm{sup −2}. Average size of dots varied from 37-95 nm in this specified range of incidence while density of dots varied from 0.17-3.0 × 107 dotscm{sup −2}. Such variations in morphological features have been supported by estimation of ion range and sputtering yield through SRIM simulations.

  8. Surface modification and metallization of polycarbonate using low energy ion beam

    International Nuclear Information System (INIS)

    Reheem, A.M. Abdel; Maksoud, M.I.A. Abdel; Ashour, A.H.

    2016-01-01

    The low energy argon ion is used for irradiation polycarbonate samples using cold cathode ion source. The surface of the PC substrates is examined using SEM, UV-spectroscopy and FTIR. It was found that the energy band gap decrease by increase argon ion fluence. Copper films are deposited onto polycarbonate (PC) substrates after irradiation by argon ion beam. The structure, surface morphology and the optical band gap are investigated using XRD, SEM and UV spectroscopy. It can be seen that the intensity increases with deposition time and band gap decreases from 3.45 eV for the pristine PC to ∼1.7 eV for copper thin film. - Highlights: • The low energy argon ion is used for irradiation polycarbonate samples. • The surface roughness increase from 9 µm to 23.5 µm after argon ion irradiated. • Copper films are deposited onto polycarbonate (PC) substrates. • Energy band gap decreases from 3.45 eV for pristine to 1.7 eV for copper thin film.

  9. Characteristics of the Nafion (registered) - impregnated polycarbonate composite membranes for PEMFCs

    International Nuclear Information System (INIS)

    Kim, Ki-Hwan; Ahn, Sang-Yeoul; Oh, In-Hwan; Ha, Heung Yong; Hong, Seong-Ahn; Kim, Moon-Sun; Lee, Youngkwan; Lee, Yong-Chul

    2004-01-01

    In this work, polycarbonate composite membranes were prepared for proton exchange membrane fuel cells (PEMFCs). In the preparation of membranes, a small amount of poly(ethylene glycol) (PEG) was blended with polycarbonate (PC) solution and then cast to make membranes. PEG contained in the membrane was removed by the high solubility of supercritical CO 2 to afford porosity in the membrane. Then, porous PC membranes were soaked in Nafion (registered) solution to yield the PC/Nafion (registered) composite membranes. The PC composite membrane had lower ion conductivity but higher conductance than Nafion (registered)

  10. Use of laser-induced breakdown spectroscopy for the determination of polycarbonate (PC) and acrylonitrile-butadiene-styrene (ABS) concentrations in PC/ABS plastics from e-waste.

    Science.gov (United States)

    Costa, Vinicius Câmara; Aquino, Francisco Wendel Batista; Paranhos, Caio Marcio; Pereira-Filho, Edenir Rodrigues

    2017-12-01

    Due to the continual increase in waste generated from electronic devices, the management of plastics, which represents between 10 and 30% by weight of waste electrical and electronic equipment (WEEE or e-waste), becomes indispensable in terms of environmental and economic impacts. Considering the importance of acrylonitrile-butadiene-styrene (ABS), polycarbonate (PC), and their blends in the electronics and other industries, this study presents a new application of laser-induced breakdown spectroscopy (LIBS) for the fast and direct determination of PC and ABS concentrations in blends of these plastics obtained from samples of e-waste. From the LIBS spectra acquired for the PC/ABS blend, multivariate calibration models were built using partial least squares (PLS) regression. In general, it was possible to infer that the relative errors between the theoretical or reference and predicted values for the spiked samples were lower than 10%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Low-voltage electroosmotic pumping using polyethylene terephthalate track-etched membrane

    Energy Technology Data Exchange (ETDEWEB)

    Wang Ceming; Wang Lin [State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Xue Jianming, E-mail: jmxue@pku.edu.cn [State Key Laboratory of Nuclear Physics and Technology, Peking University, Beijing 100871 (China); Center for Applied Physics and Technology, Peking University, Beijing 100871 (China)

    2012-09-01

    We present experimental investigations of electroosmotic (EO) pumping using polyethylene terephthalate (PET) track-etched membrane at a low applied voltage. An EO pump based on PET track-etched membrane has been designed and fabricated. Pumping performance of the device is experimentally studied in terms of flow rate as a function of applied voltage and KCl aqueous concentration. The PET track-etched membrane EO pump can generate flow rates on the order of 10 {mu}l min{sup -1} cm{sup -2} at several applied volts. The measured flow rate tends to decrease with increasing KCl aqueous concentration. In addition, we study the EO flow in cylindrical nanopore with use of a continuum model, composed of Nernst Planck equations, Poisson equation and Navier Stokes equations.

  12. Registration of alpha particles in Makrofol-E nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Rammah, Y.S. [Physics Department, Faculty of Science, Menoufia University, Shebin El-Koom (Egypt); Abdalla, Ayman M., E-mail: aymanabdalla62@hotmail.com [Physics Department, Faculty of Sciences and Arts, Najran University, P. O. Box. 11001, Najran (Saudi Arabia); Promising Centre for Sensors and Electronic Devices, Faculty of Arts and Sciences, Najran University (Saudi Arabia); Ashraf, O., E-mail: osama.ashraf@edu.asu.edu.eg [Physics Department, Faculty of Education, Ain Shams University, Cairo 11575 (Egypt); Ashry, A.H. [Physics Department, Faculty of Education, Ain Shams University, Cairo 11575 (Egypt)

    2016-06-15

    Highlights: • Makrofol-E detectors have been irradiated with alpha particles and fission fragments. • Fast detection of alpha particles in Makrofol-E detectors. • Bulk etching rate was calculated from fission track diameters. - Abstract: Fast detection of alpha particles in the range from 1 to 5 MeV in Makrofol-E polycarbonate nuclear track detectors (PCTDs) using a new chemical etchant was investigated. {sup 252}Cf and {sup 241}Am-thin open sources were used for irradiating Makrofol-E detectors with fission fragments and alpha particles in air at normal pressure and temperature (NPT). A chain of experimental work has been carried out using new etchants to register alpha particle in short time in Makrofol-E polycarbonate detectors. The etching efficiency were exhibited a clear dependence on the amount of methanol in the etching solution and etching time. The optimized chemical condition obtained at this stage of development for 200 μm Makrofol-E detectors are (8 ml of 10 N NaOH + 2 ml CH{sub 3}OH) etching solutions at 60 °C for 3 h. In this study; it is possible to observe energy detection windows for Makrofol-E detectors according to applied etching duration. Makrofol-E introduced the characteristic Bragg peak, which indicates the advantages of this detector as alpha spectrometer. Consequently, the suggested new etchant can be developed for heavy ions detection and monitoring radon levels and its daughters.

  13. Etching characteristics of a CR-39 track detector at room temperature in different etching solutions

    International Nuclear Information System (INIS)

    Dajko, G.

    1991-01-01

    Investigations were carried out to discover how the etching characteristics of CR-39 detectors change with varying conditions of the etching process. Measurements were made at room temperature in pure NaOH and KOH solutions; in different alcoholic KOH solutions (PEW solution, i.e. potassium hydroxide, ethyl alcohol, water); and in NaOH and KOH solutions containing different additives. The bulk etching rate of the detector (V B ) and the V (= V T /V B ) function, i.e. track to bulk etch rates ratio, for 6.1 MeV α-particles, were measured systematically. (author)

  14. Efficient alpha particle detection by CR-39 applying 50 Hz-HV electrochemical etching method

    International Nuclear Information System (INIS)

    Sohrabi, M.; Soltani, Z.

    2016-01-01

    Alpha particles can be detected by CR-39 by applying either chemical etching (CE), electrochemical etching (ECE), or combined pre-etching and ECE usually through a multi-step HF-HV ECE process at temperatures much higher than room temperature. By applying pre-etching, characteristics responses of fast-neutron-induced recoil tracks in CR-39 by HF-HV ECE versus KOH normality (N) have shown two high-sensitivity peaks around 5–6 and 15–16 N and a large-diameter peak with a minimum sensitivity around 10–11 N at 25°C. On the other hand, 50 Hz-HV ECE method recently advanced in our laboratory detects alpha particles with high efficiency and broad registration energy range with small ECE tracks in polycarbonate (PC) detectors. By taking advantage of the CR-39 sensitivity to alpha particles, efficacy of 50 Hz-HV ECE method and CR-39 exotic responses under different KOH normalities, detection characteristics of 0.8 MeV alpha particle tracks were studied in 500 μm CR-39 for different fluences, ECE duration and KOH normality. Alpha registration efficiency increased as ECE duration increased to 90 ± 2% after 6–8 h beyond which plateaus are reached. Alpha track density versus fluence is linear up to 10 6  tracks cm −2 . The efficiency and mean track diameter versus alpha fluence up to 10 6  alphas cm −2 decrease as the fluence increases. Background track density and minimum detection limit are linear functions of ECE duration and increase as normality increases. The CR-39 processed for the first time in this study by 50 Hz-HV ECE method proved to provide a simple, efficient and practical alpha detection method at room temperature. - Highlights: • Alpha particles of 0.8 MeV were detected in CR-39 by 50 Hz-HV ECE method. • Efficiency/track diameter was studied vs fluence and time for 3 KOH normality. • Background track density and minimum detection limit vs duration were studied. • A new simple, efficient and low-cost alpha detection method

  15. On the long standing question of nuclear track etch induction time: Surface-cap model

    International Nuclear Information System (INIS)

    Rana, Mukhtar Ahmed

    2008-01-01

    Using a systematic set of experiments, nuclear track etch induction time measurements in a widely used CR-39 detector were completed for accessible track-forming particles (fission fragments, 5.2 MeV alpha particles and 5.9 MeV antiprotons). Results of the present work are compared with appropriately selected published results. The possibility of the use of etch induction time for charged particle identification is evaluated. Analysis of experimental results along with the use of well-established theoretical concepts yielded a model about delay in the start of chemical etching of nuclear tracks. The suggested model proposes the formation of a surface-cap (top segment) in each nuclear track consisting of chemically modified material with almost same or even higher resistance to chemical etching compared with bulk material of the track detector. Existing track formation models are reviewed very briefly, which provide one of the two bases of the proposed model. The other basis of the model is the general behavior of hot or energised material having a connection with an environment containing a number of species like ordinary air. Another reason for the delay in the start of etching is suggested as the absence of localization of etching atoms/molecules, which is present during etching at depth along the latent track

  16. Development of a new approach to simulate a particle track under electrochemical etching in polymeric detectors

    International Nuclear Information System (INIS)

    Mostofizadeh, Ali; Huang, Yudong; Kardan, M. Reza; Babakhani, Asad; Sun Xiudong

    2012-01-01

    A numerical approach based on image processing was developed to simulate a particle track in a typical polymeric detector, e.g., polycarbonate, under electrochemical etching. The physical parameters such as applied voltage, detector thickness, track length, the radii of curvature at the tip of track, and the incidence angle of the particle were considered, and then the boundary condition of the problem was defined. A numerical method was developed to solve Laplace equation, and then the distribution of the applied voltage was obtained through the polymer volume. Subsequently, the electric field strengths in the detector elements were computed. In each step of the computation, an image processing technique was applied to convert the computed values to grayscale images. The results showed that a numerical solution to Laplace equation is dedicatedly an attractive approach to provide us the accurate values of electric field strength through the polymeric detector volume as well as the track area. According to the results, for a particular condition of the detector thickness equal to 445 μm, track length of 21 μm, the radii of 2.5 μm at track tip, the incidence angle of 90°, and the applied voltage of 2080 V, after computing Laplace equation for an extremely high population of 4000 × 4000 elements of detector, the average field strength at the tip of track was computed equal to 0.31 MV cm −1 which is in the range of dielectric strength for polymers. The results by our computation confirm Smythe’s model for estimating the ECE-tracks.

  17. Photoluminescent study of Polycarbonate (PC) and Poly(9-vinylcarbazole) (PVK) doped films with europium complex

    International Nuclear Information System (INIS)

    Forster, Pedro Lima

    2010-01-01

    Polymers doped with rare earth complexes are advantaged in film production for many applications in the luminescent field. In this study luminescent polymer obtained from polycarbonate (PC) and poly(9-vinylcarbazole) films doped with diaquatris(thenoyltrifluoroacetonate)europium(III) complex [Eu(tta) 3 (H 2 0) 2 ] were prepared and their calorimetric and luminescent properties in the solid state are reported. The thermal behavior was investigated by differential scanning calorimetry (OSC) and thermogravimetry analysis (TGA). Due of the addition of rare earth Eu(tta) 3 (H 2 0) 2 ] into PC and PVK matrices, changes were observed in the thermal behavior concerning the glass transition and thermal stability. Characteristic broadened narrow bands arising from the 5 D 0 -→ 7 F J transitions (J = 0-4) of Eu 3+ ion indicate the incorporation of the Eu 3+ ions into those polymers. The luminescent films show enhancement emission intensity with an increase in the rare earth concentration in polymeric matrix accompanied by decrease in thermal stability. (author)

  18. A study of etching model of alpha-recoil tracks in biotite

    International Nuclear Information System (INIS)

    Dong Jinquan; Yuan Wanming; Wang Shicheng; Fan Qicheng

    2005-01-01

    Like fission-track dating, alpha-recoil track (ART) dating is based on the accumulation of nuclear particles that the released from natural radioactivity and produce etchable tracks in solids. ARTs are formed during the alpha-decay of uranium and thorium as well as of their daughter nuclei. When emitting an alpha-particle, the heavy remaining nucleus recoils 30-40 nm, leaving behind a trail of radiation damage. Through etching the ART tracks become visible with the aid of an interference phase-contrast microscope. Under the presupposition that all tracks are preserved since the formation of a sample their total number is a measure of the sample's age. The research for etching model is to accurately determine ART volume density, i.e., the number of ARTs per unit volume. The volume density of many dots in many layers may be determined on a sample using this etching model, and as decreasing the error and increasing the accuracy. (authors)

  19. Interrelated temperature dependence of bulk etch rate and track length saturation time in CR-39 detector

    International Nuclear Information System (INIS)

    Azooz, A.A.; Al-Jubbori, M.A.

    2013-01-01

    Highlights: • New empirical parameterization of CR-39 bulk etch rate. • Bulk etch rates measurements using two different methods give consistent results. • Temperature independence of track saturation length. • Two empirical relation between bulk etch rate and temperature are suggested. • Simple inverse relation between bulk etch rate and track saturation time. -- Abstract: Experimental measurements of the etching solution temperature dependence of bulk etch rate using two independent methods revealed a few interesting properties. It is found that while the track saturation length is independent of etching temperature, the etching time needed to reach saturation is strongly temperature-dependent. It is demonstrated that there is systematic simple inverse relation between track saturation time, and etching solution temperature. In addition, and although, the relation between the bulk etch rate and etching solution temperature can be reasonably described by a modified form of the Arrhenius equation, better fits can be obtained by another equation suggested in this work

  20. Evolution of etched nuclear track profiles of alpha particles in CR-39 by atomic force microscopy

    International Nuclear Information System (INIS)

    Félix-Bautista, R.; Hernández-Hernández, C.; Zendejas-Leal, B.E.; Fragoso, R.; Golzarri, J.I.; Vázquez-López, C.; Espinosa, G.

    2013-01-01

    A series of atomic force microscopy (AFM) images of etched nuclear tracks has been obtained and used to calculate the nuclear track registration sensitivity parameter V(x) = Vt(x)/Vb. Due to the AFM limitations the samples were irradiated normally to the surface, and with energies attenuated in order to include the Bragg peak region in the AFM piezo-scanner z movement range. The simulation of the track profile evolution was then obtained. The different stages of etched nuclear track profiles were rendered. - Highlights: ► Using AFM we reach that Bragg peak region of etched tracks in CR-39. ► The etched track sensitivity V was calculated by data obtained by AFM. ► The evolucion of etched nuclear tracks was simulated by data achieved by AFM

  1. Transport through track etched polymeric blend membrane

    Indian Academy of Sciences (India)

    Unknown

    Department of Physics, University of Rajasthan, Jaipur 302 004, India. MS received 10 June 2005 ... Both the track and bulk etching takes place in the irradiated membrane. ... using rotating flywheel attachment, the details having been given ...

  2. Chemical etching of fission tracks in ethylene-tetrafluoroethylene copolymer

    International Nuclear Information System (INIS)

    Komaki, Y.; Tsujimura, S.; Seguchi, T.

    1979-01-01

    The chemical etching of fission tracks in ethylene-tetrafluoroethylene copolymer was studied. Etched holes 3000 to 4000 A in diameter were recognized by electron microscopy for a film bombarded by fission fragments in oxygen and etched in a 12N sodium hydroxide solution at 125 0 C. The radial etching rate at 125 0 C was 6 to 8 A/hr, which is less than 17 A/hr for polyvinylidene fluoride in the same sodium hydroxide concentration at 85 0 C. The smaller rate is a reflection of the larger chemical resistivity of ethylene-tetrafluoroethylene copolymer than polyvinylidene fluoride. (author)

  3. Etching behaviour of alpha-recoil tracks in natural dark mica studied via artificial ion tracks

    International Nuclear Information System (INIS)

    Lang, M.; Glasmacher, U.A.; Neumann, R.; Wagner, G.A.

    2003-01-01

    Alpha-recoil tracks (ARTs) created by the α-decay of U, Th, and their daughter nuclei, are used by a new dating method to determine the formation age of dark mica bearing Quaternary and Neogene volcanic rocks and the cooling age of plutonic and metamorphic rocks [Chem. Geol. 166 (2000) 127, Science 155 (1967) 1103]. The age equation combines the volumetric density of ARTs with the U and Th contents. Etching latent ARTs (diameter 30-100 nm) in the mica mineral phlogopite by HF and measuring the areal density of triangular etch pits by optical and scanning force microscopy (SFM) leads to a linear growth of ART areal density versus etching time. The ART volume density is a function of the slope of the areal density and the etching rate (v eff ). Therefore, the determination of v eff is essential for the calculation of an age value. To determine the etching parameters such as etching efficiency and v eff , phlogopite samples were irradiated with 80 keV Au ions. Irradiated surfaces were etched with 4% HF at 23±2 deg. C during successive time intervals and after each interval studied with SFM. The etching rate v eff was determined by different techniques. To evaluate the threshold of etchability, the energy losses of the Au ions and α-recoil nuclei in phlogopite were calculated with the SRIM00 code. The etching efficiency of the Au ion tracks was then used to predict the corresponding etching efficiency of the natural radioactive nuclei

  4. Observations on the geometries of etched fission and alpha-recoil tracks with reference to models of track revelation in minerals

    International Nuclear Information System (INIS)

    Jonckheere, R.; Enkelmann, E.; Stuebner, K.

    2005-01-01

    The kinetic and atomistic theories of crystal growth and dissolution are used to interpret the shapes and orientations of fission-track, recoil-track and dislocation etch pits in tri-octahedral phlogopite and di-octahedral muscovite. An atomistic approach combined with symmetry considerations lead to the identification of the periodic bond chains that determine the etch pit morphologies and relative etch rates at a chemical level: O-Mg-O in phlogopite, O-Mg-O-Fe in biotite and O-Al-O in muscovite. Using first-order estimates of the bond strengths, it is possible to account for the relative track etch rates in these minerals. The reported, sometimes simultaneous, occurrence of triangular, polygonal and hexagonal etch pit contours in phlogopite, some of which violate the crystal symmetry, suggests that the cohesion of the phlogopite lattice is lost over a much larger radius than that of the track core around the trajectories of particles for which the energy loss exceeds a threshold value. This is interpreted as an indication of pronounced sublattice and anisotropic effects during track registration

  5. Grafting on nuclear tracks using the active sites that remain after the etching process

    International Nuclear Information System (INIS)

    Mazzei, R.; Bermudez, G. Garcia; Chappa, V.C.; Grosso, M.F. del; Fernandez, A.

    2006-01-01

    Poly(propylene) foils were irradiated with Ag ions and then chemically etched to produce samples with structured surfaces. After the etching procedure the active sites that remain on the latent track were used to graft acrylic acid. Nuclear tracks before grafting were visualised using a transmission electron microscope. The grafting yields were determined by weight measurements as a function of ion fluence, etching and grafting time, and were also analysed using Fourier transform infrared spectroscopy. Both measurements suggest that the acrylic acid was grafted on etched tracks using the active sites produced by the swift heavy ion beam

  6. Grafting on nuclear tracks using the active sites that remain after the etching process

    Energy Technology Data Exchange (ETDEWEB)

    Mazzei, R. [Unidad de Aplicaciones Tecnologicas y Agropecuarias, CNEA, 1429 Buenos Aires (Argentina) and Universidad Tecnologica Nacional, Buenos Aires (Argentina)]. E-mail: mazzei@cae.cnea.gov.ar; Bermudez, G. Garcia [U. A. de Fisica, Tandar, CNEA, 1429 Buenos Aires (Argentina); Escuela de Ciencia y Tecnologia, UNSAM, 1653 Buenos Aires (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (Argentina); Chappa, V.C. [U. A. de Fisica, Tandar, CNEA, 1429 Buenos Aires (Argentina); Grosso, M.F. del [U. A. de Fisica, Tandar, CNEA, 1429 Buenos Aires (Argentina); U. A. de Materiales, CNEA, 1429 Buenos Aires (Argentina); Fernandez, A. [Universidad Tecnologica Nacional, Buenos Aires (Argentina)

    2006-09-15

    Poly(propylene) foils were irradiated with Ag ions and then chemically etched to produce samples with structured surfaces. After the etching procedure the active sites that remain on the latent track were used to graft acrylic acid. Nuclear tracks before grafting were visualised using a transmission electron microscope. The grafting yields were determined by weight measurements as a function of ion fluence, etching and grafting time, and were also analysed using Fourier transform infrared spectroscopy. Both measurements suggest that the acrylic acid was grafted on etched tracks using the active sites produced by the swift heavy ion beam.

  7. Degradation of polycarbonate induced by gamma radiation

    International Nuclear Information System (INIS)

    Araujo, E.S. de; Guedes, S.M.L.

    1992-01-01

    Polycarbonate (PC) DUROLON amorphous, of molecular weight 22000 g/mol is used in medical supplies and may be sterilized by gamma radiation. The main chain scission and polymer degradation occur when this polymer is irradiated. The value G = 1.54 to DUROLON was obtained by equation: 10 6 /M v = 10 6 /M v' + 0.054 G R. The degradation without crosslinking it is not general rule to all types of polycarbonates; an comparison was realized. The infrared (FT-IR) spectra of irradiated PC by gamma rays with different doses showed the main chain scissions in carbonyl groups. The mechanism of polymeric degradation to DUROLON, observed by NMR spectra, is a recombination of phenoxy and phenyl radicals. (author)

  8. Vacuum effect on the etch induction time and registration sensitivity of polymer track detectors

    International Nuclear Information System (INIS)

    Csige, I.; Hunyadi, I.; Somogyi, G.

    1988-01-01

    The effect of a vacuum on etch induction time and track etch rate ratio of some polymer track detectors was studied systematically with alpha particles of different energies. It was found that the etch induction time increases, and the track etch rate ratio decreases, drastically when the detectors were irradiated in a vacuum and also kept in a vacuum for a few hours before and for a few minutes after the irradiation. These times proved to be characteristic for the outgassing of oxygen from the sheets and the stabilization of latent tracks, respectively. The role of oxygen in latent track formation is discussed. We have found that the vacuum effect is most significant near the surface. Its diminution with depth depends on the time of outgassing in accordance with the time variation of the dissolved oxygen concentration profile inside the sheets. (author)

  9. Vacuum effect on the etch induction time and registration sensitivity of polymer track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Csige, I.; Hunyadi, I.; Somogyi, G. (Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete); Fujii, M. (Institute of Space and Astronautical Science, Sagamihara (Japan))

    1988-01-01

    The effect of a vacuum on etch induction time and track etch rate ratio of some polymer track detectors was studied systematically with alpha particles of different energies. It was found that the etch induction time increases, and the track etch rate ratio decreases, drastically when the detectors were irradiated in a vacuum and also kept in a vacuum for a few hours before and for a few minutes after the irradiation. These times proved to be characteristic for the outgassing of oxygen from the sheets and the stabilization of latent tracks, respectively. The role of oxygen in latent track formation is discussed. We have found that the vacuum effect is most significant near the surface. Its diminution with depth depends on the time of outgassing in accordance with the time variation of the dissolved oxygen concentration profile inside the sheets. (author).

  10. Symphony and cacophony in ion track etching: how to control etching results

    Czech Academy of Sciences Publication Activity Database

    Fink, Dietmar; Kiv, A.; Cruz, S. A.; Munoz, G. H.; Vacík, Jiří

    2012-01-01

    Roč. 167, č. 7 (2012), s. 527-540 ISSN 1042-0150 R&D Projects: GA AV ČR IAA200480702 Institutional support: RVO:61389005 Keywords : ion track s * polymers * etching * diodes * resistances Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.502, year: 2012

  11. Measurements of diffusion parameters of methanol on gamma-irradiated polycarbonate

    International Nuclear Information System (INIS)

    Silva, Pietro P.J.C.G.P.O.; Araujo, Elmo S.

    2013-01-01

    Polycarbonate (PC) is an engineering polymer which presents interesting properties such as toughness, light weight and transparency. This material has been used for several important applications including in the medical field. In this particular application, polycarbonate has been exposed frequently to gamma irradiation and to chemical environment that can be able to product significant changes in polymer structure that may lead to future catastrophic fail and rupture. Polymer structural damages induced by gamma irradiation or chemical attack (environment stress cracking) have been studied by several research groups for many years and for many solvent-polymer systems, but few reporters present informations about the simultaneous occurrence of these effects. This present work has the goal to understand the diffusion process of methanol in polycarbonate and to determinate the diffusion parameters on polymer system under 100 kGy of gamma irradiation. Swelling experiments were performed at the samples of polycarbonate divided in two groups: PC-0 (without dose) and PC-100 (with 100 kGy of dose). Diffusion parameters (D) may be measured by slope of the sorption curve for polymers with Fickian behavior. A comparison of the D parameters was made for each set of sample. There were no significant differences on D values of sample groups observed due to the radiation effects. However, stress strain curves obtained show that methanol has great influence on mechanical behavior of PC but the radiation dose don't have significant influence on this mechanical behavior. (author)

  12. Funnel-type etched ion tracks in polymers

    Czech Academy of Sciences Publication Activity Database

    Fink, Dietmar; Vacík, Jiří; Hnatowicz, Vladimír; Munoz, G. H.; Alfonta, L.; Klinkovich, I.

    2010-01-01

    Roč. 165, č. 5 (2010), s. 343-361 ISSN 1042-0150 R&D Projects: GA AV ČR(CZ) KAN400480701 Institutional research plan: CEZ:AV0Z10480505 Keywords : tracks * polymers * etching Subject RIV: JJ - Other Materials Impact factor: 0.660, year: 2010

  13. Electrical Transport Through Micro Porous Track Etch Membranes of same Porosity

    Science.gov (United States)

    Garg, Ravish; Kumar, Vijay; Kumar, Dinesh; Chakarvarti, S. K.

    2012-12-01

    Porosity, pore size and thickness of membrane are vital factors to influence the transport phenomena through micro porous track etch membranes (TEMs) and affect the various applications like separations, drug release, flow control, bio-sensing and cell size detection etc. based on transport process. Therefore, a better understanding of transport mechanism through TEMs is required for new applications in various thrust areas like biomedical devices and packaging of foods and drugs. Transport studies of electrolytic solutions of potassium chloride, through porous polycarbonate TEMS having cylindrical pores of size 0.2 μm and 0.4 μm with same porosity of 15%, have been carried out using an electrochemical cell. In this technique, the etched filter is sandwiched between two compartments of cell in such a way that the TEM acts as a membrane separating the cell into two chambers. The two chambers are then filled with electrolyte solution (KCl in distilled water). The current voltage characteristics have been drawn by stepping the voltage ranging 0 to 10 V using Keithley 2400 Series Source Measurement Unit. The results indicate that rate of ion transport through cylindrical pores although is independent of pore size of TEMs of same porosity but there seems to be effect of TEM aperture size exposed to the electrolyte used in conducting cell on ion transport magnitude. From the experimental studies, a large deviation in the conduction through TEMs was observed when compared with theoretical consideration which led to the need for modification in the applicability of simple Ohm's law to the conduction through TEMs. It is found that ion transport increases with increase in area of aperture of TEM but much lower than the expected theoretically value.

  14. Fatigue Fracture Behaviors of Transparent Polycarbonate Materials

    OpenAIRE

    ZHANG Xiao-wen; WU Nan; ZHANG Xuan; MA Li-ting; LI Lei

    2017-01-01

    The effect of the different stress ratios (R) and annealing treatment on the fatigue properties of the transparent polycarbonate (PC) sheet and the mechanism behind were studied, the fatigue crack propagation (FCP) process and mechanism were analyzed. The results show that after annealing, the residual stress of the PC samples decreases obviously and the fatigue properties are greatly improved. This is because the machining process results in tensile stress in the PC samples, eliminating the ...

  15. Image analysis used to count and measure etched tracks from ionizing radiation

    Science.gov (United States)

    Blanford, George E.; Schulz, Cindy K.

    1995-01-01

    We have developed techniques to use digitized scanning electron micrographs and computer image analysis programs to measure track densities in lunar soil grains and plastic dosimeters. Tracks in lunar samples are formed by highly ionizing solar energetic particles and cosmic rays during near surface exposure on the Moon. The track densities are related to the exposure conditions (depth and time). Distributions of the number of grains as a function of their track densities can reveal the modality of soil maturation. We worked on two samples identified for a consortium study of lunar weathering effects, 61221 and 67701. They were prepared by the lunar curator's staff as polished grain mounts that were etched in boiling 1 N NaOH for 6 h to reveal tracks. We determined that backscattered electron images taken at 10 percent contrast and approximately 50 percent brightness produced suitable high contrast images for analysis. We used the NIH Image program to cut out areas that were unsuitable for measurement such as edges, cracks, etc. We ascertained a gray-scale threshold of 25 to separate tracks from background. We used the computer to count everything that was two pixels or greater in size and to measure the area to obtain track densities. We found an excellent correlation with manual measurements for track densities below 1 x 10(exp 8) cm(exp -2). For track densities between 1 x 10(exp 8) cm(exp -2) to 1 x 10(exp 9) cm(exp -2) we found that a regression formula using the percentage area covered by tracks gave good agreement with manual measurements. We determined the track density distributions for 61221 and 67701. Sample 61221 is an immature sample, but not pristine. Sample 67701 is a submature sample that is very close to being fully mature. Because only 10 percent of the grains have track densities less than 10(exp 9) cm(exp -2), it is difficulty to determine whether the sample matured in situ or is a mixture of a mature and a submature soil. Although our analysis

  16. On the structure of etched ion tracks in polymers

    Czech Academy of Sciences Publication Activity Database

    Hnatowicz, Vladimír; Vacík, Jiří; Apel, P. Yu.

    2016-01-01

    Roč. 121, APR (2016), s. 106-109 ISSN 0969-806X R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠk(CZ) LM2011019 Institutional support: RVO:61389005 Keywords : polymers * ion tracks * track etching Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.315, year: 2016

  17. Evidence of blocking effects on 3-keV Ne7+ ions guided through nanocapillaries in polycarbonate

    International Nuclear Information System (INIS)

    Stolterfoht, N.; Hellhammer, R.; Sulik, B.; Juhasz, Z.; Bayer, V.; Trautmann, C.; Bodewits, E.; Hoekstra, R.

    2011-01-01

    We studied the dynamic properties of ion guiding through nanocapillaries etched in insulating polycarbonate (PC). Capillaries with diameters of 95 and 165 nm and a length of 10 μm were used. In a further sample, the capillaries had a diameter of 175 nm and a length of 30 μm. A few additional measurements were made using capillaries in polyethylene terephthalate (PET). The temporal evolution of the intensity and the angular distribution of the transmitted ions were studied by measuring transmission profiles as a function of the charge deposited on the sample surface. The tilt angle of the capillary axis was varied from 0 deg. to 5 deg. The mean emission angle of the transmission profiles exhibit pronounced oscillations, similarly as in previous measurements using PET. However, for PC, nearly an order of magnitude more charge needs to be inserted into the capillaries to accomplish the oscillations. In contrast to PET, with PC, we observed a strong decrease of the profile intensities with irradiation time. This observation provides evidence of blocking effects on the ions, which are likely to be due to a repulsive field produced by significant charge deposition inside the PC capillaries.

  18. Neutron activation analysis of uranium by means of electrochemical etching of tracks in lawsan detectors

    International Nuclear Information System (INIS)

    Kim Son Chun; Chuburkov, Yu.T.; Zvara, I.I.

    1982-01-01

    The method of neutron activation analysis of uranium in natural and artificial materials using track lavsan detectors of fission fragments has been developed. The method of electrochemical etching (etching reagent NaOH) of fragment tracks in lavsan is improved. Using statistical method of experiment planning the equation, describing the dependence of diometer value of fission fragment tracks on parameters of etching process, is obtained. The analysis sensitivity is 10 - 7 g/g - 10 - 8 g/g

  19. Track-etch detection of radon in soils

    International Nuclear Information System (INIS)

    Cervantes Gonzales, P.; Gonzalez, D.

    1990-01-01

    In this work it is described the methodology to apply the track-etch technique, using detectors of nitrocellulose LR-115, for the detection of radon in soil. It is supported the use of the new detector carries and determined the parameters for revealing and counting of tracks in our conditions. It is shown in a preliminary way that this method gives better possibilities for analysis than another traditional technique to radon detection. The existence of radon was determined in the test zone. 15 refs

  20. CONTRIBUTION OF DIFFERENT PARTICLES MEASURED WITH TRACK ETCHED DETECTORS ONBOARD ISS.

    Science.gov (United States)

    Ambrožová, I; Davídková, M; Brabcová, K Pachnerová; Tolochek, R V; Shurshakov, V A

    2017-09-29

    Cosmic radiation consists of primary high-energy galactic and solar particles. When passing through spacecraft walls and astronauts' bodies, the spectrum becomes even more complex due to generating of secondary particles through fragmentation and nuclear interactions. Total radiation exposure is contributed by both these components. With an advantage, space research uses track etched detectors from the group of passive detectors visualizing the tracks of particles, in this case by etching. The detectors can discriminate between various components of cosmic radiation. A method is introduced for the separation of the different types of particles according to their range using track etched detectors. The method is demonstrated using detectors placed in Russian segment of the International Space Station in 2009. It is shown that the primary high-energy heavy ions with long range contribute up to 56% of the absorbed dose and up to 50% to the dose equivalent. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Enlarging the fission fragment tracks in glass detectors by etching in weak solutions of HF - a safe etchant

    International Nuclear Information System (INIS)

    Singh, V.P.; Sharma, A.P.

    1982-01-01

    The effect of etchant concentration and temperature on track revelation properties of soda glass detectors has been studied. Etch rate ratio, maximum observable diameter and the energy resolution of the fission fragment tracks of 252 Cf in glasses are increased when the samples are etched in 1.25 vol% HF as compared to higher concentrations of HF and other etching solutions. The critical angle of etching is found to decrease with decrease in etchant concentration. The activation energies for bulk etching and track etching have also been estimated. Better results were obtained by using lower etching temperatures. (author)

  2. Study on some characteristics of the polycarbonate Durolon used as a solid state nuclear track detector

    International Nuclear Information System (INIS)

    Sciani, V.; Pugliesi, R.; Moraes, M.A.P.V. de; Menezes, M.O. de; Miranda, A.

    1994-01-01

    Some characteristics of the polycarbonate Durolon as a solid state nuclear track detector were investigated. These were determined by means of irradiations performed at the IEA-R1 Nuclear Research Reactor of the IPEN-CNEN/SP. The results were compared with those obtained for Makrofol-E at the same conditions. Although Durolon is grooved, it presents a track registration efficiency and a light transmission of about 30% and 2,4 greater than the former, respectively. (author). 7 refs, 4 figs, 2 tabs

  3. Investigations of gamma irradiation on the properties of luminescent films of polycarbonate(PC) matrix doped with europium complex [Eu(tta)3(H2O)2

    International Nuclear Information System (INIS)

    Forster, Pedro L.; Lugao, Ademar B.; Martins, Natalia A.; Egute, Nayara S.; Parra, Duclerc F.; Brito, Hermi F.

    2009-01-01

    Luminescent lanthanide complexes have attracted much recent interest for their application as luminescent materials. The combination of unique spectroscopic properties from rare earth complexes associated to physical and chemical intrinsic properties of polymers became more attractive in the last years. A number of advantages of these substances have been reported or realized over the much studied conjugated polymers and nonlanthanide. Luminescent films composed by diaquatris(thenoyltrifluoroacetonate)europium(III) complex [Eu(tta) 3 (H 2 O) 2 ] doped into a polycarbonate (PC) matrix were prepared and irradiated at gamma radiation with 5, 10, and 20 kGy. The PC polymer was doped with 1% (w/w) of the Eu 3+ complex. The thermal properties was investigated by utilization of differential scanning calorimeter (DSC) changes in thermal stability was observed due to the addition of doping agent into the polycarbonate matrix. Changes in photophysical properties due of gamma radiation was observed by emission, excitation spectra and fourier transformed infrared spectra (FTIR). Based on the emission spectra of PC:1% Eu(tta)3 film were observed the characteristic bands arising from the 5 D 0 7 F J transitions of Eu 3+ ion (J=0-4), indicating the ability to obtain the luminescence films. (author)

  4. Etching of fission tracks in silicate glasses by means of deionized water

    International Nuclear Information System (INIS)

    Dran, J.C.; Petit, J.C.

    1985-09-01

    Fission tracks have been revealed in silicate glasses with deionized water. Their sharp conical shape implies a marked enhancement of the dissolution rate along their core and consequently a cone angle and an etching efficiency (close to 100%) much higher than previously reported for glasses. We show that etching of fission tracks in natural environments has generally very limited geochemical implications except in specific cases such as that found in the Oklo uranium ores

  5. Comparative study of the mechanical properties from different polycarbonates

    International Nuclear Information System (INIS)

    Terence, M.C.; Miranda, A.; Guedes, S.M.L.; Sciani, V.

    1995-01-01

    The polycarbonates (PC) with molecular weight 22000 and 27000 g/mol fabricated by Policarbonatos do Brasil S.A., as irradiated by γ rays with doses between 0 and 300 kGy in presence of air at room temperature. The effects in the mechanical properties of PC were investigated using an INSTRON dynamometer. The results showed that both PC have good mechanical stability. (author). 6 refs, 2 figs

  6. The use of track-etch detectors for assessing radon concentrations

    International Nuclear Information System (INIS)

    Kendall, G.M.

    2002-01-01

    The author describes the track-etch dosimetry system used by the National Radiological Protection Board for measuring radon concentrations in dwellings and in workplaces. It also considers the criteria which should be satisfied by an ideal radon dosimetry system aimed at large-scale assessments of the risk from inhalation of radon decay products in room air. The present NRPB track-etch dosimetry system is matched against the requirements of such and ideal system. There is a brief description of the role of screening measurements designed to show whether there are dangerous levels of radon decay products in a house without giving an accurate assessment of their true long-term average concentration

  7. Non-etching nuclear track visualization in polymers: fluorescent and dyed tracks

    International Nuclear Information System (INIS)

    Somogyi, G.; Toth-Szilagyi, M.; Monnin, M.; Gourcy, J.

    1979-01-01

    A report is presented on progress in two methods of non-etching nuclear track visualization. The basis for one method is to graft polymer chains in the vicinity of the ion path in a polymer, and then to dye it, making the track visible. The second method is similar, but in this case saturated organic molecules can be used, which prevents subsequent polymerization. The detector is soaked with a solution of a sensitization molecule that can react with a convenient dye and fix it. The sensitization molecules may diffuse into the detector either through the bulk of it or/ and along the region damaged by a charged particle. Depending on the detailed procedure used, the tracks may be seen as 'dyed tracks' with visible-light illumination or as 'fluorescent tracks' with u.v. illumination. Experimental procedures and results are given and discussed. (U.K.)

  8. Manufacture of anti-bogus label by track-etching technique

    International Nuclear Information System (INIS)

    He Xiangming; Wan Chunrong

    2006-01-01

    Anti-bogus label is manufactured by the track-etching technique. The apparent pattern on the label consists of track-etched pores on the membrane. The manufacture of the label depends on the intricate technology and the state strictly controls the sensitive nuclear facilities, ensuring that the label is not copied. The pattern on the label is specially characterized by permeability of liquid in order to distinguish it from a forged one. A genuine label can be distinguished from a sham one by a transparent liquid (e.g. water) or a colorful pen. Nowadays, the products of more than 100 famous brands (trade mark) have been protected from forgery by this technology in the market of China. This is a new method for the utilization of a research reactor

  9. Etching Properties of Poly ethyleneterephthalate (PET) Melinex-E Nuclear Track Detectors (NTDs)

    International Nuclear Information System (INIS)

    Ghanim, E.H.; Hussein, A.; El-samman, H.M.; Tretyakova, S.P.

    2009-01-01

    One of the main parameters that control track formation is the bulk etch rate, VB. The dependence of VB on etchant concentrations and temperatures was extensively carried out. It is found that, VB of the PET Melinex-E (C 10 H 8 O 4 ) depends upon the etchant temperature T through an Arrhenius equation. While, the dependence of VB on the etchant concentration; C followed the relation VB = A C n. The activation energy of etching, Eb, for the studied Melinex-E detector was calculated. An average value of Eb = 0.83 ± 0.03 eV was extracted. The variation of, VB, of PET with etching duration was studied and compared with that of CR-39 plastic at certain etching temperature; T e =60 degree C and at different etchant concentrations. The irradiation facilities were performed with the 252 Cf fission fragments and 129 Xe +8 (θi =π/2). Results of these studies were discussed in the frame work of nuclear track formation and etching theories

  10. Optical properties and oxidation of carbonized and cross-linked structures formed in polycarbonate by plasma immersion ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kosobrodova, E., E-mail: elenak@physics.usyd.edu.au [Department of Applied Plasma and Physics, School of Physics, University of Sydney, NSW 2006 (Australia); Kondyurin, A. [Department of Applied Plasma and Physics, School of Physics, University of Sydney, NSW 2006 (Australia); Chrzanowski, W. [Faculty of Pharmacy, University of Sydney, NSW 2006 (Australia); Department of Nanobiomedical Science and BK21 PLUS NBM Global Research, Center for Regenerative Medicine, Dankook University, Cheonan 330-714 (Korea, Republic of); McCulloch, D.G. [School of Applied Sciences, RMIT University, Melbourne, Victoria 3001 (Australia); McKenzie, D.R.; Bilek, M.M.M. [Department of Applied Plasma and Physics, School of Physics, University of Sydney, NSW 2006 (Australia)

    2014-06-01

    Highlights: • Structure and properties of polycarbonate films spin-coated on silicon are studied. • The films have two thicknesses: thicker and thinner than a depth of ion penetration. • Effect of radio frequency plasma and plasma immersion ion implantation is compared. - Abstract: At ion fluences higher than 5 · 10{sup 15} ions/cm{sup 2}, plasma immersion ion implantation (PIII) of polycarbonate (PC) results in a formation of a carbonized surface layer. The thickness of this layer is close to the depth of ion penetration. A comparison of PIII treated, spin-coated PC films with pre-treatment thicknesses designed to match and exceed the carbonized layer thickness is employed to study the properties of the carbonised layer independently from the less modified underlying structure. At ion fluencies higher than 10{sup 16} ions/cm{sup 2}, the thinner PC film is completely transformed into an amorphous carbon-like material with no traces of the initial PC structure. The thicker films, however, incorporated two layers: a top carbonised layer and a cross-linked layer below. Compared to the two-layered PC film, the completely carbonized layer was found to have a much higher concentration of C=O bonds and much lower concentration of O–H bonds after exposure to atmospheric oxygen. The refractive index of the thicker PC films PIII treated with high ion fluencies is close to the refractive index of diamond-like carbon. Anomalous dispersion of the refractive index of the thicker PC films is observed after formation of the carbonised layer. The refractive index of the thinner PC film has normal dispersion at all ion fluences. At ion fluences of 2 · 10{sup 16} ions/cm{sup 2}, both PC films were found to have the same etching rate as polystyrene. Washing in dichloromethane had no effect on the carbonised layer but affected the underlying material in the case of the thicker PC films leading to a wrinkled structure up to ion fluences of 2 · 10{sup 16} ions/cm{sup 2}. At

  11. Measurement of the variable track-etch rate of hydrogen, carbon and oxygen Ions in CR-39

    International Nuclear Information System (INIS)

    Lengar, I.; Skvarc, J.; Ilic, R.

    2003-01-01

    The ratio of the track-etch rate to the bulk-etch rate for hydrogen, carbon and oxygen ions was studied for the CR-39 detector with addition of dioctylphthalate. The response was reconstructed from etch-pit growth curves obtained by the multi-step etching technique. A theoretical analysis of the correctness of the method due to the 'missing track segment' is assessed and utilisation of the results obtained for the calibration of fast neutron dosimetry is discussed. (author)

  12. Optimization of microwave-induced chemical etching for rapid development of neutron-induced recoil tracks in CR-39 detectors

    International Nuclear Information System (INIS)

    Sahoo, G.S.; Tripathy, S.P.; Bandyopadhyay, T.

    2014-01-01

    A systematic investigation is carried out to optimize the recently established microwave-induced chemical etching (MICE) parameters for rapid development of neutron-induced recoil tracks in CR-39 detectors. Several combinations of all available microwave powers with different etching durations were analysed to determine the most suitable etching condition. The etching duration was found to reduce with increasing microwave power and the tracks were observed at about 18, 15, 12, and 6 min for 300, 450, 600 and 900 W of microwave powers respectively compared to a few hours in chemical etching (CE) method. However, for complete development of tracks the etching duration of 30, 40, 50 and 60 min were found to be suitable for the microwave powers of 900, 600, 450 and 300 W, respectively. Temperature profiles of the etchant for all the available microwave powers at different etching durations were generated to regulate the etching process in a controlled manner. The bulk etch rates at different microwave powers were determined by 2 methods, viz., gravimetric and removed thickness methods. A logarithmic expression was used to fit the variation of bulk etch rate with microwave power. Neutron detection efficiencies were obtained for all the cases and the results on track parameters obtained with MICE technique were compared with those obtained from another detector processed with chemical etching. - Highlights: • Microwave-induced chemical etching method is optimized for rapid development of recoil tracks due to neutrons in CR-39 detector. • Several combinations of microwave powers and etching durations are investigated to standardize the suitable etching condition. • Bulk-etch rates are determined for all microwave powers by two different methods, viz. gravimetric and removed thickness method. • The method is found to be simple, effective and much faster compared to conventional chemical etching

  13. Ultrasound effects on the electrolytically controlled etching of nuclear track filters (NTFs)

    International Nuclear Information System (INIS)

    Chakarvarti, S.K.; Mahna, S.K.; Sud, L.V.; Singh, P.

    1990-01-01

    The mechanical stirring of the etchant creates tremendous changes in the etching properties of SSNTDs. Ultrasound stirring also produces a number of effects in liquids by giving a rapid movement to etchant. Cavitation is the most probable phenomenon caused by ultrasound and responsible for most of the effects observed in chemical reactions. Microbubbles are created in liquid medium and explosion of these microbubbles is responsible for momentarily rise in temperature. The possible effects of ultrasound on etching of particle tracks in plastic track detectors as nuclear track filters has been studied. The ultrasound effects on V t and V b have been studied in this work. (author). 5 re fs

  14. Ion track etching revisited: II. Electronic properties of aged tracks in polymers

    Czech Academy of Sciences Publication Activity Database

    Fink, Dietmar; Hernandez, G. M.; Cruz, S. A.; Garcia-Arellano, H.; Vacík, Jiří; Hnatowicz, Vladimír; Kiv, A.; Alfonta, L.

    2018-01-01

    Roč. 173, 1-2 (2018), s. 148-164 ISSN 1042-0150 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : polymers * ion tracks * etching * conductometry * rectification * phase shift Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 0.443, year: 2016

  15. Ion track etching revisited: I. Correlations between track parameters in aged polymers

    Czech Academy of Sciences Publication Activity Database

    Fink, Dietmar; Munoz, G. H.; García Arellano, H.; Vacík, Jiří; Hnatowicz, Vladimír; Kiv, A.; Alfonta, L.

    2018-01-01

    Roč. 420, č. 4 (2018), s. 57-68 ISSN 0168-583X R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : ion track * polymer * etching Subject RIV: BG - Nuclear, Atomic and Molecular Physics , Colliders OBOR OECD: Nuclear physics Impact factor: 1.109, year: 2016

  16. A passive monitor for radon using electrochemical track etch detector

    International Nuclear Information System (INIS)

    Massera, G.E.; Hassib, G.M.; Piesch, E.

    1980-01-01

    A passive, inexpensive monitor for radon detection and dosimetry is described in detail. It consists of a Makrofoil track etch detector inside a diffusion chamber which is sealed by a fibreglass filter through which radon may diffuse while radon daughters and aerosols are retained on the surface of the filter. The α-particle tracks are revealed by etching the Makrofoil in KOH. The lower detection limit of the radon dosimeter is equivalent to a mean dose in the lung of 130 mrem. After an exposure period of 3 months, a mean radon concentration of 0.3 pCi/l can be detected. The instrument is intended for use in a study to measure the long-term radon exposure in buildings in West Germany. (UK)

  17. ATMS software: Fuzzy Hough Transform in a hybrid algorithm for counting the overlapped etched tracks and orientation recognition

    International Nuclear Information System (INIS)

    Khayat, O.; Ghergherehchi, M.; Afarideh, H.; Durrani, S.A.; Pouyan, Ali A.; Kim, Y.S.

    2013-01-01

    A computer program named ATMS written in MATLAB and running with a friendly interface has been developed for recognition and parametric measurements of etched tracks in images captured from the surface of Solid State Nuclear Track Detectors. The program, using image analysis tools, counts the number of etched tracks and depending on the current working mode classifies them according to their radii (small object removal) or their axis (non-perpendicular or non-circular etched tracks), their mean intensity value and their orientation through the minor and major axes. Images of the detectors' surfaces are input to the code, which generates text and figure files as output, including the number of counted etched tracks with the associated track parameters, histograms and a figure showing edge and center of detected etched tracks. ATMS code is running hierarchically as calibration, testing and measurement modes to demonstrate the reliability, repeatability and adaptability. Fuzzy Hough Transform is used for the estimation of the number of etched tracks and their parameters, providing results even in cases that overlapping and orientation occur. ATMS code is finally converted to a standalone file which makes it able to run out of MATLAB environment. - Highlights: ► Presenting a novel code named ATMS for nuclear track measurements. ► Execution in three modes for generality, adaptability and reliability. ► Using Fuzzy Hough Transform for overlapping detection and orientation recognition. ► Using DFT as a filter for noise removal process in track images. ► Processing the noisy track images and demonstration of the presented code

  18. Technical feasibility study on polycarbonate solar panels

    NARCIS (Netherlands)

    Hackmann, M.M.; Meuwissen, M.H.H.; Bots, T.L.; Buijs, J.A.H.M.; Broek, K.M.; Kinderman, R.; Tanck, O.B.F.; Schuurmans, F.M.

    2004-01-01

    This paper describes a technical feasibility study on the application of polycarbonate (PC) plates in a superstrate photovoltaic module design. The lamination process was performed in a conventional laminator apparatus using low temperature curing (100°C) ethylene-vinyl-acetate (EVA) as the potting

  19. Modification of track membranes structure by gas discharge etching method

    International Nuclear Information System (INIS)

    Dmitriev, S.N.; Kravets, L.I.

    1996-01-01

    An investigation of the properties of polyethyleneterephthalate track membranes (PET TM) treated with the plasma RF-discharge in air has been performed. The influence of the plasma treatment conditions on the basic properties of the membranes, namely pore size and pore shape, porosity and mechanical strength has been studied. It was arranged that the effect of air plasma on the PET TM results to etching a membrane's surface layer. The membranes' pore size and the form in this case change. It is shown that it is possible to change the structure of track membranes directly by the gas discharge etching method. Depending on the choice of discharge parameters, it is possible to make etching either in a part of the channel or along the whole length of the pore channels. In both cases the membranes with an asymmetric pore shape are formed which possess higher porosity and flow rate. The use of the membranes of such a type allows one to increase drastically the efficiency of the filtration processes. 12 refs., 5 figs., 1 tab

  20. Fabrication and Antibacterial Effects of Polycarbonate/Leaf Extract Based Thin Films

    Directory of Open Access Journals (Sweden)

    R. Mahendran

    2016-01-01

    Full Text Available We have reported the preparation and antibacterial activities of leaf extract incorporated polycarbonate thin films to improve the antibacterial characteristics of host polycarbonates (PCs. Crude extracts of Azadirachta indica, Psidium guajava, Acalypha indica, Andrographis paniculata, and Ocimum sanctum were prepared by maceration using Dimethylformamide as solvent. The leaf extracts (LE were incorporated into the PC matrix by solution blending method, and the thin films were fabricated by Thermally Induced Phase Separation (TIPS technique. The antibacterial activities of the as-prepared films were evaluated against E. coli and S. aureus by disk diffusion method. The inhibitory effects of the PC/LE films are higher for S. aureus than the E. coli, but pristine PC film did not exhibit any remarkable antibacterial characteristics. Further, the model fruit (Prunus studies revealed that the PC/LE films retained the freshness of the fruits for more than 11 days. This study demonstrates that the PC/LE films have excellent antibacterial activities; thus, the films could be promising candidate for active antibacterial packaging applications.

  1. Estimation of track registration efficiency in solution medium and study of gamma irradiation effects on the bulk-etch rate and the activation energy for bulk etching of CR-39 (DOP) Solid State Nuclear Track Detector

    International Nuclear Information System (INIS)

    Kalsi, P.C.

    2010-01-01

    The fission track registration efficiency of diethylene glycol bis allyl carbonate (dioctyl phthalate doped) (CR-39 (DOP)) solid state nuclear track detector (SSNTD) in solution medium (K wet ) has been experimentally determined and is found to be (9.7 ± 0.5).10 -4 cm. This is in good agreement with the values of other SSNTDs. The gamma irradiation effects in the dose range of 50.0-220.0 kGy on the bulk etch rate, V b and the activation energy for bulk etching, E of this solid state nuclear track detector (SSNTD) have also been studied. It is observed that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation

  2. Phase separation and orientation in EVA/polycarbonate

    International Nuclear Information System (INIS)

    Martins-Franchetti, S.M.; Nunes, S.P.

    1988-01-01

    Blends of the polycarbonate of bisphenol-A-(PC) with poly(ethylene-co-vinylacetate) (EVA) were prepared by solution casting in different solvents and various proportions. Their behaviours was examined by diferential scanning calorimetry (DSC), X-ray diffraction and u.v. spectrophotometry. The results obtained show that PC and EVA form partially miscible blends. In some cases, birefringence was observed by optical microscopy indicating the occurrence of polymer orientation in the neighbourhood of the interfaces. (author) [pt

  3. Functionalization of nanochannels by radio-induced grafting polymerization on PET track-etched membranes

    International Nuclear Information System (INIS)

    Soto Espinoza, S.L.; Arbeitman, C.R.; Clochard, M.C.; Grasselli, M.

    2014-01-01

    The application of swift-heavy ion bombardment to polymers is a well-established technique to manufacture micro- and nanopores onto polymeric films to obtain porous membranes. A few years ago, it was realized that, during ion bombardment, the high energy deposition along the ion path through the polymer reached cylindrical damage regions corresponding to the core trace and the penumbra. After the etching procedure, there are still enough active sites left in the penumbra that can be used to initiate a polymerization process selectively inside the membrane pores. In this study, we report the grafting polymerization of glycidyl methacrylate onto etched PET foils to obtain functionalized nanochannels. Grafted polymers were labeled with a fluorescent tag and analyzed by different fluorescence techniques such as direct fluorescence, fluorescence microscopy and confocal microscopy. These techniques allowed identifying and quantifying the grafted regions on the polymeric foils. - Highlights: • Irradiated PET foils with swift-heavy ions were etched and grafted in a step-by-step process. • Grafting polymerization was performed on the remaining active sites after etching. • Track-etched PET membranes were fluorescently labeled by chemical functionalization. • Functionalized track-etched PET membranes were analyzed by fluorescence and confocal microscopy

  4. Personnel neutron dosimetry applications of track-size distributions on electrochemically etched CR-39 foils

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1988-01-01

    The track-size distribution on electrochemically etched CR-39 foils can be used to obtain some limited information on the incident neutron spectra. Track-size distributions on CR-39 foils can also be used to determine if the tracks were caused by neutrons or if they are merely background tracks (which have a significantly different track-size distribution). Identifying and discarding the high-background foils reduces the number of foils that must be etched. This also lowers the detection limit of the dosimetry system. We have developed an image analyzer program that can more efficiently determine the track density and track-size distribution, as well as read the laser-cut identification numbers on each foil. This new image analyzer makes the routine application of track-size distributions on CR-39 foils feasible. 2 refs., 3 figs

  5. The solid state track detectors for α-particles angular distribution measurements

    International Nuclear Information System (INIS)

    Bakr, M.H.S.

    1978-01-01

    The solid state track detectors technique is described in details from the point of view of applying them in nuclear reactions research. Using an optimum developing solution, the etching rate of polycarbonate detector was found to be 10.5 μ/hour. The energy resolution of this detector was estimated using 241 Am α-source at α-energies between 1 and 3 Mev. The scattering chamber designed for angular distribution measurements using solid state track detectors is described. A special schematic normograph for range-energy-degrading foils relation is given

  6. Track profile and range studies of heavy and light ions in CR-39: effect of thermal pre-treatment on etching characteristics

    International Nuclear Information System (INIS)

    Al-Najjar, S.A.R.; Bull, R.K.; Durrani, S.A.

    1982-01-01

    Sheets of CR 39 have been irradiated with 20 Ne, 32 S, 40 Ar, 56 Fe and 63 Cu ions at normal incidence to the surface of the sheets and at normal incidence to the edges. The profiles of the etched tracks have been observed side-on and measurements made of the variation of V (the ratio of track to bulk etching velocities) along the tracks and of the fully etched range of the tracks. Heating the plastic at 100 0 C prior to etching produces zones within the plastic having different bulk etching rates Vsub(B). An outer zone of low Vsub(B) is followed by a zone of much higher Vsub(B). This allows tracks to be readily etched to very large diameters, comparable in size to the breakdown spots produced by electrochemical etching. (author)

  7. Polycarbonate as an Elasto-Plastic Material Model for Simulation of the Microstructure Hot Imprint Process

    Directory of Open Access Journals (Sweden)

    Rokas Šakalys

    2013-08-01

    Full Text Available The thermal imprint process of polymer micro-patterning is widely applied in areas such as manufacturing of optical parts, solar energy, bio-mechanical devices and chemical chips. Polycarbonate (PC, as an amorphous polymer, is often used in thermoforming processes because of its good replication characteristics. In order to obtain replicas of the best quality, the imprint parameters (e.g., pressure, temperature, time, etc. must be determined. Therefore finite element model of the hot imprint process of lamellar periodical microstructure into PC has been created using COMSOL Multiphysics. The mathematical model of the hot imprint process includes three steps: heating, imprinting and demolding. The material properties of amorphous PC strongly depend on the imprint temperature and loading pressure. Polycarbonate was modelled as an elasto-plastic material, since it was analyzed below the glass transition temperature. The hot imprint model was solved using the heat transfer and the solid stress-strain application modes with thermal contact problem between the mold and polycarbonate. It was used for the evaluation of temperature and stress distributions in the polycarbonate during the hot imprint process. The quality of the replica, by means of lands filling ratio, was determined as well.

  8. Helium ion distributions in a 4 kJ plasma focus device by 1 mm-thick large-size polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M., E-mail: dr_msohrabi@yahoo.com; Habibi, M.; Ramezani, V.

    2014-11-14

    Helium ion beam profile, angular and iso-ion beam distributions in 4 kJ Amirkabir plasma focus (APF) device were effectively observed by the unaided eyes and studied in single 1 mm-thick large-diameter (20 cm) polycarbonate track detectors (PCTD). The PCTDs were processed by 50 Hz–HV electrochemical etching using a large-size ECE chamber. The results show that helium ions produced in the APF device have a ring-shaped angular distribution peaked at an angle of ∼±60° with respect to the top of the anode. Some information on the helium ion energy and distributions is also provided. The method is highly effective for ion beam studies. - Highlights: • Helium iso-ion beam profile and angular distributions were studied in the 4 kJ APF device. • Large-area 1 mm-thick polycarbonate detectors were processed by 50 Hz-HV ECE. • Helium ion beam profile and distributions were observed by unaided eyes in a single detector. • Helium ion profile has ring-shaped distributions with energies lower at the ring location. • Helium iso-ion track density, diameter and energy distributions are estimated.

  9. Track etch parameters and annealing kinetics assessment of protons of low energy in CR-39 detector

    International Nuclear Information System (INIS)

    Jain, R.K.; Kumar, Ashok; Singh, B.K.

    2012-01-01

    Highlights: ► We calibrate CR-39 detector with very low energy protons. ► We establish linear relationship between track diameter and time/energy up to 200 keV. ► We determine activation energy of annealing using different models. ► We justify concept of single annealing activation energy in CR-39. - Abstract: In this paper threshold of the registration sensitivity of very low energy proton in CR-39 is investigated. Irradiation of CR-39 (poly-allyl-diglycol carbonate) was carried out with very low energy mono energetic protons of 20–60 keV from a mini proton accelerator. Nearly 10 4 /cm 2 fluence of protons was used. The variation of track diameter with etching time as well as proton energy response curve was carefully calibrated. The bulk and track etch rates were measured by using proton track diameters. Bulk etch rate was also measured by the thickness of removed surface layer. The thermal annealing of proton track at temperatures ranging from 100 to 200 °C in CR-39 was studied by several models. Activation energy of annealed CR-39 detectors was calculated by slope of track etch rate and temperature plot. The data of proton tracks of 200, 250 and 300 keV from 400 kV Van-de-Graaff accelerator was also used and compared with the track diameters of different energies of proton.

  10. ZnTe Amorphous Semiconductor Nanowires Array Electrodeposited into Polycarbonate Membrane Thin Films

    International Nuclear Information System (INIS)

    Ohgai, T; Ikeda, T; Ohta, J

    2013-01-01

    ZnTe amorphous semiconductor nanowires array was electrodeposited into the nanochannels of ion-track etched polycarbonate membrane thin films from acidic aqueous solution at 313 K. ZnTe electrodeposits with Zn-rich composition was obtained over the wide range of cathode potential from −0.8 V to −1.1 V and the growth rate of ZnTe amorphous nanowires was around 3 nm.sec −1 at the cathode potential of −0.8 V. Cylindrical shape of the nanowires was precisely transferred from the nanochannels and the aspect ratio reached up to ca. 40. ZnTe amorphous phase electrodeposited at 313 K was crystallized by annealing at 683 K and the band gap energy of ZnTe crystalline phase reached up to ca. 2.13 eV.

  11. Track-etch dosemeter response to neutrons up to 300 MeV

    International Nuclear Information System (INIS)

    Devine, R.T.; Walker, S.; Staples, P.; Duran, M.; Mundis, R.; Miller, J.

    1996-01-01

    Electro-chemical and chemical track-etch dosemeters were obtained from commercial suppliers and exposed to neutrons produced at the LANTF WNR white neutron source at 15 degree with no shielding and filtered by polyethylene blocks of 2.5, 5.1, 10.2, 20.3 and 40.6 cin thickness. The neutron spectrum was determined using calculations. Mean energies from 28 to 300 MeV were produced. Dose was calculated from the NCRP-38 flux-to-dose conversion. The results are compared with NTA film which was exposed in the same configuration. The response of track etch dosimeters was found to reach a minimum and then rise as the average neutron energy increased. The response of the NTA film increased as the neutron energy increased

  12. Production parameters for the formation of metallic nanotubules in etched tracks

    International Nuclear Information System (INIS)

    Fink, D.; Petrov, A.V.; Rao, V.; Wilhelm, M.; Demyanov, S.; Szimkowiak, P.; Behar, M.; Alegaonkar, P.S.; Chadderton, L.T.

    2003-01-01

    The formation of conducting nanotubules in etched tracks is reported in literature since about a decade. However, up to now precise production recipes are scarce. For this sake we present here a systematic study on some important factors that influence the formation of metallic nanotubules. In the case of chemical deposition, the first question to be answered is the choice of the activation technique to produce the required activation centers. Both the time of activation and the time of subsequent chemical deposition are crucial parameters in this connection. Finally, the maximum temperature is determined up to which thermal stability of the etched tracks and of the tubules therein is given. This study should allow one to predict better the efficiency of conducting nanotubule formation

  13. Low-temperature oxidizing plasma surface modification and composite polymer thin-film fabrication techniques for tailoring the composition and behavior of polymer surfaces

    Science.gov (United States)

    Tompkins, Brendan D.

    This dissertation examines methods for modifying the composition and behavior of polymer material surfaces. This is accomplished using (1) low-temperature low-density oxidizing plasmas to etch and implant new functionality on polymers, and (2) plasma enhanced chemical vapor deposition (PECVD) techniques to fabricate composite polymer materials. Emphases are placed on the structure of modified polymer surfaces, the evolution of polymer surfaces after treatment, and the species responsible for modifying polymers during plasma processing. H2O vapor plasma modification of high-density polyethylene (HDPE), low-density polyethylene (LDPE), polypropylene (PP), polystyrene (PS), polycarbonate (PC), and 75A polyurethane (PU) was examined to further our understanding of polymer surface reorganization leading to hydrophobic recovery. Water contact angles (wCA) measurements showed that PP and PS were the most susceptible to hydrophobic recovery, while PC and HDPE were the most stable. X-ray photoelectron spectroscopy (XPS) revealed a significant quantity of polar functional groups on the surface of all treated polymer samples. Shifts in the C1s binding energies (BE) with sample age were measured on PP and PS, revealing that surface reorganization was responsible for hydrophobic recovery on these materials. Differential scanning calorimetry (DSC) was used to rule out the intrinsic thermal properties as the cause of reorganization and hydrophobic recovery on HDPE, LDPE, and PP. The different contributions that polymer cross-linking and chain scission mechanisms make to polymer aging effects are considered. The H2O plasma treatment technique was extended to the modification of 0.2 microm and 3.0 microm track-etched polycarbonate (PC-TE) and track-etched polyethylene terephthalate (PET-TE) membranes with the goal of permanently increasing the hydrophilicity of the membrane surfaces. Contact angle measurements on freshly treated and aged samples confirmed the wettability of the

  14. Equipment for electrochemical etching of dielectric track detectors

    International Nuclear Information System (INIS)

    Turek, K.; Novak, M.

    1992-01-01

    The facility is designed for electrochemical etching of solid state track detectors, devised for thicknesses in excess of 200 μm as employed for direct detection of charged particles or neutrons. The device consists of a high-voltage a.c. supply for the electrodes and an assembly whose body consists of a flat tank, on the surface of which is formed a channel for feeding the heating and cooling media. The tank is covered by a gasket, an earthed metal plate for the detector, a mask with holes determining the shape of the etched area, and a pressure plate. The pressure plate is fitted with a system of holes for the etching solution. Needle-shaped high-voltage electrodes are accommodated in the holes of the mask. The underlying principle of the invention consists in the fact that a rubber pad with guide holes for the needle-shaped electrodes lies on the pressure plate. Each electrode is composed of a central tip and an outer jacket, separated by an insulating layer; connection is provided by a light emitting diode. (Z.S.). 2 figs

  15. 3D computation of the shape of etched tracks in CR-39 for oblique particle incidence and comparison with experimental results

    International Nuclear Information System (INIS)

    Doerschel, B.; Hermsdorf, D.; Reichelt, U.; Starke, S.; Wang, Y.

    2003-01-01

    Computation of the shape of etch pits needs to know the varying track etch rate along the particle trajectories. Experiments with alpha particles and 7 Li ions entering CR-39 detectors under different angles showed that this function is not affected by the inclination of the particle trajectory with respect to the normal on the detector surface. Track formation for oblique particle incidence can, therefore, be simulated using the track etch rates determined for perpendicular incidence. 3D computation of the track shape was performed applying a model recently described in literature. A special program has been written for computing the x,y,z coordinates of points on the etch pit walls. In addition, the etch pit profiles in sagittal sections as well as the contours of the etch pit openings on the detector surface have been determined experimentally. Computed and experimental results were in good agreement confirming the applicability of the 3D computational model in combination with the functions for the depth-dependent track etch rates determined experimentally

  16. Study of substrate topographical effects on epithelial cell behavior using etched alpha-particle tracks on PADC films

    International Nuclear Information System (INIS)

    Ng, C.K.M.; Poon, W.L.; Li, W.Y.; Cheung, T.; Cheng, S.H.; Yu, K.N.

    2008-01-01

    Micrometer-size pits on the surface of a polymer (polyallyldiglycol carbonate or PADC) substrate created by alpha-particle irradiation and subsequent chemical etching were used to study the topographical effects alone on cell behavior. Vinculin, the cell adhesion and membrane protrusion protein, was used as an indicator of cytoskeletonal reorganization on the substrate and localization of vinculin was used to demonstrate the presence of focal adhesions. In our experiments, vinculin expressed in epithelial HeLa cells cultured on PADC films with track-etch pits, but not in cells cultured on the raw or chemically etched blank films. In other words, vinculin expression was induced by the topography of track-etch pits, while etching of the substrate alone (without alpha-particle irradiation) did not cause up-regulation of vinculin protein expression. HeLa cells cultured on PADC films with track-etch pits also showed changes in cell proliferation, cell area and cell circularity, and were largely contained by the pits. In other words, the cell membrane edges tended to be in contact with the pits. By comparing the correlation between the positions of HeLa cells and the pits, and that between the positions of cells and computer-simulated pits, the tendency for membrane edges of HeLa cells to be in contact with the pits was recognized. This could be explained by inhibition of membrane protrusion at the pits. In conclusion, substrate track-etch pits were an important determinant of epithelial cell behaviors

  17. Breakthrough in fake prevention. Nuclear track-etching

    International Nuclear Information System (INIS)

    Yan Yushun; He Xiangming; Zhang Quanrong

    1999-01-01

    Nuclear particle track-etched anti-counterfeit marking is a new weapon against fake products. The marks is manufactured by intricate high technology in state-controlled sensitive nuclear facilities which ensures that the mark can not be copied. The pattern of the mark is characterized by its permeability, and can be distinguished from fakes by using a transparent liquid (e.g. water), colored pen or chemical reagent. The technique has passed the of facial health safety examination and poses no danger of nuclear irradiation

  18. A strategy for achieving low percolation and high electrical conductivity in melt-blended polycarbonate (PC/multiwall carbon nanotube (MWCNT nanocomposites: Electrical and thermo-mechanical properties

    Directory of Open Access Journals (Sweden)

    B. B. Khatua

    2013-06-01

    Full Text Available In this work, polycarbonate (PC/multiwall carbon nanotube (MWCNT nanocomposites were prepared by simple melt mixing at a temperature (~350°C well above the processing temperature of PC, followed by compression molding, that exhibited percolation threshold as low as of 0.11 wt% and high electrical conductivity of 1.38x10–3 S•cm–1 at only 0.5 wt% MWCNT loading. Due to the lower interfacial energy between MWCNT and PC, the carbon nanotubes are excellently dispersed and formed continuous conductive network structure throughout the host polymer. AC electrical conductivity and dielectric permittivity of PC/MWCNT nanocomposites were characterized in a broad frequency range, 101–107 Hz. Low percolation threshold (pc of 0.11 wt% and the critical exponent (t of ~3.38 was resulted from scaling law equation. The linear plot of logσDC vs. p–1/3 supported the presence of tunneling conduction among MWCNTs. The thermal property and storage modulus of PC were increased with the incorporation of little amount of MWCNTs. Transmission electron microscopy (TEM and field emission scanning electron microscopy (FESEM confirmed the homogeneous dispersion and distribution of MWCNTs throughout the matrix phase.

  19. Study etching characteristics of a track detector CR-39 with ultraviolet laser irradiation

    International Nuclear Information System (INIS)

    Dwaikat, Nidal; Iida, Toshiyuki; Sato, Fuminobu; Kato, Yushi; Ishikawa, Ippei; Kada, Wataru; Kishi, Atsuya; Sakai, Makoto; Ihara, Yohei

    2007-01-01

    The effect of pulsed ultraviolet Indium-doped Yttrium Aluminum Garnet (UV-In:YAG) laser of λ=266 nm, pulse energy 42 mJ/pulse at repetition rate10 Hz on the etching characteristics of Japanese CR-39 was studied at various energy intensities. Fifteen detectors were divided into two sets, each of seven samples and one sample was kept as a reference.The first set (post-exposed) was first exposed to alpha radiation with close contact to 241 Am and then treated in air with laser in the energy intensity range from 40 to160 J/cm 2 , 20 J/cm 2 in step. The second set (pre-exposed) was irradiated in reverse process (laser+alpha) with the same sources as the first set and under the same condition. The laser energy intensities ranged between 20 and 140 J/cm 2 , 20 J/cm 2 in step. For post-exposed samples (alpha+laser) bulk etch rate decreases up to 60 J/cm 2 and increases thereafter, while for pre-exposed samples (laser+alpha) the bulk etch rate oscillates without showing any precise periodicity. The bulk etch rate for both sets was found to be the same at 60≤energy intensity≤80 J/cm 2 and this may indicate that the same structural changes have happened. The track etch rate was found to be equal to the bulk etch rate for both sets, so the sensitivity is constant. In both sets several changes on the detector surfaces: tracks of different sizes and shapes and high density within the laser spot were observed. Out of the laser spot, the tracks become larger and lower density, indicating cross-linking and scission have happened, simultaneously, on the same surface as a result of UV-laser irradiation

  20. Bulk etching characteristics of CR-39 track detectors in hydroxide solutions

    International Nuclear Information System (INIS)

    Fonseca, E.S. da; Knoefel, T.M.J.; Tavares, O.A.P.

    1983-01-01

    A systematic study of the bulk etch rate of CR-39 track detectors in KOH and NaOH aqueous solutions is presented. A number of unirradiated and non-thermally treated CR-39 samples were chemically attacked in KOH and NaOH solutions of concentration and temperature in the range 2-10 N and 50-90 0 C, respectively. From measurements of the thickness of layers removed as a function of the etching time, the bulk etch rate υ β and the induction time T ο for surface removal were obtained for each etching condition. For both NaOH and KOH solution the activation energy of the process was derived as E = 0.76 ± 0.05 eV. It was observed that the induction time decreases both with increasing normality and temperature of the solution. (author) [pt

  1. Some aspects of the etching behavior of cellulose nitrate as track detector

    International Nuclear Information System (INIS)

    Hildebrand, D.; Reitz, G.; Buecker, H.

    1976-01-01

    Experimental results are presented to support the hypothesis that the etching velocity in cellulose nitrate detectors is dependent on the local water content of the foil. The consequence is drawn that high concentrations (> 4.7 n) of the etching solution should not be used for high precision track etching. The possibility to vary the Vsub(t)/Vsub(b) ratio is reported to have a useful application in biological experiments. Further more an influence of etch products at low NaOH concentrations was found. The cellulose nitrate detectors used in this investigation are 250 μ sheets made by Daicel, Nippon (plasticized) and 100 μ sheets made by Kodak, France (Type CA 80-15, plasticized). No qualitative differences in the etching behaviour of these two materials were obtained regarding the reported investigations, although the differences are partly large regarding other features. (orig.) [de

  2. Taheri-Saramad x-ray detector (TSXD): a novel high spatial resolution x-ray imager based on ZnO nano scintillator wires in polycarbonate membrane.

    Science.gov (United States)

    Taheri, A; Saramad, S; Ghalenoei, S; Setayeshi, S

    2014-01-01

    A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 μm, respectively.

  3. Taheri-Saramad x-ray detector (TSXD): A novel high spatial resolution x-ray imager based on ZnO nano scintillator wires in polycarbonate membrane

    Energy Technology Data Exchange (ETDEWEB)

    Taheri, A., E-mail: at1361@aut.ac.ir; Saramad, S.; Ghalenoei, S.; Setayeshi, S. [Department of Energy Engineering and Physics, Amirkabir University of Technology, Tehran 15875-4413 (Iran, Islamic Republic of)

    2014-01-15

    A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 μm, respectively.

  4. LET spectrometry with track etch detectors-Use in high-energy radiation fields

    International Nuclear Information System (INIS)

    Jadrnickova, I.; Spurny, F.

    2008-01-01

    For assessing the risk from ionizing radiation it is necessary to know not only the absorbed dose but also the quality of the radiation; radiation quality is connected with the physical quantity linear energy transfer (LET). One of the methods of determination of LET is based on chemically etched track detectors. This contribution concerns with a spectrometer of LET based on the track detectors and discusses some results obtained at: ·high-energy radiation reference field created at the SPS accelerator at CERN; and ·onboard of International Space Station where track-etch based LET spectrometer has been exposed 273 days during 'Matrjoshka - R' experiment. Results obtained are compared with the results of studies at some lower-energy neutron sources; some conclusions on the registrability of neutrons and the ability of this spectrometer to determine dose equivalent in high-energy radiation fields are formulated

  5. Magnetoelectrolysis of Co nanowire arrays grown in a tracketched polycarbonate membrane

    Energy Technology Data Exchange (ETDEWEB)

    Radu, Florin [BESSY GmbH, Berlin (Germany); Rivero, Guillermo; Marin, Pilar; Hernando, Antonio [Instituto de Magnetismo Aplicado, Madrid (Spain); Sanchez-Barriga, J. [Instituto de Magnetismo Aplicado, Madrid (Spain); BESSY GmbH, Berlin (Germany); Lucas, M. [Inst. fuer Theoretische Physik, Technische Univ. Berlin (Germany)

    2007-07-01

    Arrays of Cobalt nanowires with a controlled length of 6{mu}m have been fabricated by electrochemical deposition into the pores of track-etched polycarbonate membranes with a nominal pore diameter of 30 nm. The magnetic properties of Co-deposited nanowires and the effects of a magnetic field applied during electrodeposition of the arrays have been studied. An enhancement of the mass deposition rate due to the presence of a 50 Oe magnetic field along the nanowire axis has been observed by measuring the experimental development of the current in the electrochemical cell during the fabrication process. X-Ray diffraction measurements reveal a different polycrystalline degree for each deposition configuration, indicating that the crystalline structure of the deposited material has been substantially modified. Magnetic measurements show a clear dependence of the anisotropy directions on the orientation of the magnetic field applied during the electrodeposition.

  6. Radon Measurements in Egypt using passive etched track detectors. A Review

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A [National Network of Radiation Physics. Atomic Energy Authority (Egypt); Hussein, A S [Radiation Protection Department, Nuclear Power Plants Authority, (Egypt); El-Arabi, A M [Physics Department, Faculty of Science, South Valley University, Qena, (Egypt)

    2005-04-01

    Radon and its progeny may cause serious radiation harm to human health such as lung cancer and other types. Radon measurements based on alpha particles etched track detectors (LR-115, CR-39) are very attractive for assessment of radon exposure. This is due to their high sensitivity, low cost, easy to handle and retain a permanent record of data. Also these detectors can incorporate the effects of seasonal and diurnal fluctuation of radon activity concentrations due to physical, geological and meteorological factors. The present review is based mainly on the topic of passive etched track detectors for the measurements of radon in Egypt in the recent years. Published papers includes the measurements of radon in dwellings, working places, Cairo Metro stations, ancient Pharaonic places and uranium exploration galleries as well as assessment of radon in drinking water.

  7. Radon Measurements in Egypt using passive etched track detectors. A Review

    International Nuclear Information System (INIS)

    Gomaa, M.A.; Hussein, A.S.; El-Arabi, A.M.

    2005-01-01

    Radon and its progeny may cause serious radiation harm to human health such as lung cancer and other types. Radon measurements based on alpha particles etched track detectors (LR-115, CR-39) are very attractive for assessment of radon exposure. This is due to their high sensitivity, low cost, easy to handle and retain a permanent record of data. Also these detectors can incorporate the effects of seasonal and diurnal fluctuation of radon activity concentrations due to physical, geological and meteorological factors. The present review is based mainly on the topic of passive etched track detectors for the measurements of radon in Egypt in the recent years. Published papers includes the measurements of radon in dwellings, working places, Cairo Metro stations, ancient Pharaonic places and uranium exploration galleries as well as assessment of radon in drinking water

  8. Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M.; Habibi, M., E-mail: mortezahabibi@gmail.com; Ramezani, V. [Amirkabir University of Technology, Energy Engineering and Physics Department (Iran, Islamic Republic of)

    2017-02-15

    The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

  9. Monopole-track characteristics in plastic detectors

    Science.gov (United States)

    Ahlen, S. P.

    1976-01-01

    Total and restricted energy loss rates are calculated for magnetic monopoles of charge g = 137 e in Lexan polycarbonate. Range-energy curves are also presented. The restricted-energy-loss model is used to estimate the appearance of a monopole track in plastic detectors. The results are applied to the event observed by Price et al. and identified by them as a monopole. It is found that the observed etch rate is consistent with what one would expect for a slow magnetic monopole. These results should also be of use to other investigators for both the design and analysis of monopole experiments.

  10. Coherent light scattering by nuclear etched tracks in the PADC (a form of CR-39)

    Energy Technology Data Exchange (ETDEWEB)

    Groetz, J.E.; Chambaudet, A. [Universite de Franche-Comte, Besancon (France). Lab. de Microanalyses Nucleaires; Lacourt, A. [Laboratoire d`Optique P.M. Duffieux, UMR 6603 CNRS, Universite de Franche-Comte, 16 route de Gray, 25030 Besancon Cedex (France)

    1998-08-01

    A new kind of measurement has been proposed to improve the reading of the solid state nuclear track detector CR-39. This method is based on coherent light scattering (He-Ne laser) by etched proton tracks, and is complementary to observation under an optical microscope and reading by optical density of the CR-39. The irradiated and chemically etched CR-39 sample is illuminated by a laser beam under a normal incidence angle. The light intensity diffracted by the tracks beyond the sample - defined with the bi-directional transmissive distribution functions - is measured with a photodiode. Thus, the bi-directional transmissive distribution functions depend on the characteristics of the irradiation, namely the track density, track sizes and orientations. We have performed a track light diffraction model calculation through the use of the Fraunhofer diffraction, Babinet`s principle and the spatial coherence and incoherence. We compared calculations and experimental results for the different shapes of tracks: conical, oblique and spherical-shaped. (orig.) 14 refs.

  11. Coherent light scattering by nuclear etched tracks in the PADC (a form of CR-39)

    International Nuclear Information System (INIS)

    Groetz, J.E.; Chambaudet, A.

    1998-01-01

    A new kind of measurement has been proposed to improve the reading of the solid state nuclear track detector CR-39. This method is based on coherent light scattering (He-Ne laser) by etched proton tracks, and is complementary to observation under an optical microscope and reading by optical density of the CR-39. The irradiated and chemically etched CR-39 sample is illuminated by a laser beam under a normal incidence angle. The light intensity diffracted by the tracks beyond the sample - defined with the bi-directional transmissive distribution functions - is measured with a photodiode. Thus, the bi-directional transmissive distribution functions depend on the characteristics of the irradiation, namely the track density, track sizes and orientations. We have performed a track light diffraction model calculation through the use of the Fraunhofer diffraction, Babinet's principle and the spatial coherence and incoherence. We compared calculations and experimental results for the different shapes of tracks: conical, oblique and spherical-shaped. (orig.)

  12. Mapping of transuranic elements in soil by nuclear track methodology

    International Nuclear Information System (INIS)

    Espinosa, G.

    2001-01-01

    An alternative method is presented to map the distribution of transuranic elements, which is characterized by its simplicity in both implementation and instrumentation. The method is based on the interaction of alpha particles in polymeric materials and the formation of tracks, which become visible after chemical etching. Nuclear track detectors are placed on the soil in order to evaluate the distribution of the radioactive material and its relative intensity for transuranic contaminants. CR-39 polycarbonate was used as a nuclear track detector in this study. Chemical etching was done with a 6.25M KOH solution in a closed system for 16 hours. The readings were performed in an automatic system using digital image analysis. The results show the distribution of the contaminants and their location, identifying the zones with large intensities. This method is attractive for use in areas contaminated with alpha particles, and specially transuranic elements, because it involves in situ measurements, generates very low amounts of radioactive waste, and the detectors are easily handled. (author)

  13. Measurement of neutron dose and spectra at light-water reactors

    International Nuclear Information System (INIS)

    Soldat, K.L.; Endres, G.W.R.; Cummings, F.M.

    1982-08-01

    In choosing one dosimeter over another, both sensitivity and precision must be addressed. It has been determined that dosimeters employing NTA film lack adequate sensitivity for use inside containment of nuclear plants. From this study, it is apparent that CR-39 and polycarbonate track etch films used without radiators are also inadequate. The rest of the dosimeters tested displayed adequate sensitivity. The two general types of dosimeters which comprise that group are: (1) TLDs and (2) the polycarbonate track etch which was used in conjunction with (n, α) radiators. The precision of the TLD dosimeter depends on the calibration technique and response correction technique. TLD dosimeters calibrated to D 2 O-moderated californium-252 or corrected based on 9- to 3-in. sphere response rates seemed to function best inside reactor containment. Polycarbonate track etch film with (n, α) radiators was found to be sensitive enough for use inside reactor containment; however, the standard deviation for the results was roughly twice the value of the most precise TLD albedo dosimeters. Also, several of the polycarbonate dosimeters saturated, rendering any evaluation impossible

  14. Technique of neutron-induced (fission-track) autoradiography with histological detail

    International Nuclear Information System (INIS)

    Smith, J.M.; Taylor, G.N.; Jee, W.S.S.

    1980-01-01

    The primary advantage of neutron-induced or fission-track autoradiography compared with conventional autoradiography is that for low concentrations of fissile nuclides prohibitively long exposure times may be avoided. However, it is difficult to produce imaging of biological structures on the neutron-induced autoradiograph which would allow localization of the nuclide histologically. The technique presented circumvents this difficulty using a thin polycarbonate film applied to the histologically stained tissue section mounted on a quartz substrate. After irradiation of the tissue section with an appropriate thermal neutron flux, the fission fragment tracks are revealed by etching the film with KOH. The tracks, superimposed on the stained tissue, may be observed under the light microscope in the same manner as for conventional nuclear emulsion autoradiography

  15. Nanocomposites of recycled polycarbonate and nano-zinc oxide (rPC/nZnO): effect of gamma radiation and nano oxide content on the thermal properties

    International Nuclear Information System (INIS)

    Carvalho, A.L.F.; Mendes, L.C.; Cestari, S.P.

    2014-01-01

    In order to promote the barrier action to the ultraviolet radiation and increase of mechanical characteristics, nanocomposites of recycled polycarbonate (rPC) and nano-zinc oxide (nZnO) containing 1, 2 and 3 % (wt/wt) of nano oxide were prepared. Since for obtaining nanocomposites and irradiating polymers are promising tools and attractive for improving the material performance, the effects of nano-zinc oxide and gamma radiation, at doses ranged from 10 to 50 kGy, were evaluated in terms of thermal characteristics of the rPC. The rPC/nZnO nanocomposites were characterized by thermogravimetric analysis (TGA) and differential explanatory calorimetry (DSC). There was a progressive decrease of the T_g as function of gamma dosage and nano-zinc oxide content. Initially, the Tonset and Tmax decayed as function of gamma dosage but a recovery was observed. The amount of nano-zinc oxide induced a decreasing of T_o_n_s_e_t and T_m_a_x. (author)

  16. Personal neutron monitoring using TLD albedo combined with etched tracks detector

    Energy Technology Data Exchange (ETDEWEB)

    Tsujimura, N.; Momose, T. [Japan Nuclear Cycle Development Institute, Ibarakiken (Japan)

    2002-07-01

    The albedo dosimetry has been carried out in personal neutron monitoring in the MOX fuel plant of JNC Tokai Works, however, it has shortcomings mainly due to the inherently poor energy response. This paper describes our efforts to overcome these difficulties in practical use of albedo dosemeters. The following four subjects are presented: (1) the neutron energy response functions of albedo TLD obtained from the mono-energetic neutron irradiation experiments and the Monte-Carlo calculations, (2) the location- dependent correction factors calculated from the response functions and neutron energy spectra measured in the workplaces, (3) the results of the international personal neutron dosimetry intercomparison program, and (4) the operational comparison program of TLD albedo and etched tracks detector worn by workers engaged in the fabrication process of the MOX fuel plant. Finally, the characteristics of the combination neutron dosemeter using TLD albedo and solid state etched track detector are summarized.

  17. Development of a reader for track etch detectors based on a commercially available slide scanner

    CERN Document Server

    Steele, J D; Tanner, R J; Bartlett, D T

    1999-01-01

    NRPB has operated a routine neutron personal dosimetry service based on the electrochemical etch of PADC elements since 1986. Since its inception it has used an automated reader based on a video camera and real time analysis. A new and more powerful replacement system has been developed using a commercially available photographic slide scanner. This permits a complete image of the dosemeter to be grabbed in a single scan, generating a 2592x3888 pixel file which is saved for subsequent analysis. This gives an effective pixel size of 10x10 mu m with an image of the entire dosemeter in one field of view. Custom written software subsequently analyses the image to assess the number of etched pits on the dosemeter and read the detector identification number (code). Batch scanning of up to 40 detectors is also possible using an autofeed attachment. The system can be used for electrochemically etched tracks for neutron detectors and chemically etched tracks for radon detectors.

  18. Electron spin resonance investigations on polycarbonate irradiated with U ions

    Energy Technology Data Exchange (ETDEWEB)

    Chipara, M.I.; Reyes-Romero, J

    2001-12-01

    Electron spin resonance investigations on polycarbonate irradiated with uranium ions are reported. The dependence of the resonance line parameters (line intensity, line width, double integral) on penetration depth and dose is studied. The nature of free radicals induced in polycarbonate by the incident ions is discussed in relation with the track structure. The presence of severe exchange interactions among free radicals is noticed.

  19. Effect of various etching conditions on the response of Cr-39 plastic track detector applied for radon dosimetry in environment

    International Nuclear Information System (INIS)

    Maged, A.F.; Ashraf, F.A.

    1997-01-01

    A solid state nuclear track detector Cr-39 has been used for measuring the radon concentration in the soil air and indoor concentration. The bulk etch rate, C B of Cr-39 has been measured in various concentrations of NaOH in the range (6-8 mole) at temperature 70 degree C. In addition, the track etch rate, V T , and the ratio V = V T /V B , of alpha particles emitted from radon gas exists in nature have been measured in a similar range of etching conditions. This study shows that 8 M NaOH at 70 degree C represent the optimum etching conditions for Cr-39, with the range of the present study. The equilibrium factor and gamma-dose equivalent were calculated by using the track densities of open and filtered solid state nuclear track detectors

  20. Measurement of radon and thoron present in the environment using nuclear track etch detector technique

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Lalit, B.Y.; Mishra, U.C.

    1986-01-01

    The use of solid state nuclear track detectors (SSNTD) is one of the most convenient techniques to assess the average radiation levels of alpha activities in the environment. This technique has been used to assess the radon and thoron concentrations in some high background areas of South India and underground non-uranium mines in Bihar State. Exposed SSNTD films are chemically etched in an alkali solution and the alpha tracks are evaluated under an optical microscope. The detailed procedure for this study and the calibration of the etched films for conversion of alpha track density to radon and thoron concentrations in pCi l -1 are given in this paper. It was found that 1.9 tracks cm -2 day -1 and 6.2 tracks cm -2 day -1 were produced by exposing the LR-115 foils to 1 pCi l -1 of thoron and radon respectively. (author)

  1. Charged particle spectroscopy with solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Hunyadi, I.; Somogyi, G.

    1984-01-01

    Some of earlier and recent methods for differentiation of charged particles according to their energy, based on the use of polymeric etch-track detectors (CN, CA, PC and CR-39) are outlined. The principle of three track methods suitable for nuclear spectroscopy is discussed. These are based on the analysis of the diameter, surface size and shape of etch-track 'cones' produced by charged particles in polymers, after using shorter or longer chemical etching processes. Examples are presented from the results of the last decade in ATOMKI, Debrecen, Hungary, concerning the application of nuclear track spectroscopy to different low-energy nuclear reaction studies, angular distribution and excitation function measurements. These involve the study of (d,α) reaction on sup(14)N, sup(19)F and sup(27)Al nuclei, (sup(3)He,α) reactions on sup(15)N, (p,α) reaction on sup(27)Al and the process sup(12)C(sup(12)C, sup(8)Be)sup(16)O. (author)

  2. Helium ion distributions in a 4 kJ plasma focus device by 1 mm-thick large-size polycarbonate detectors

    Science.gov (United States)

    Sohrabi, M.; Habibi, M.; Ramezani, V.

    2014-11-01

    Helium ion beam profile, angular and iso-ion beam distributions in 4 kJ Amirkabir plasma focus (APF) device were effectively observed by the unaided eyes and studied in single 1 mm-thick large-diameter (20 cm) polycarbonate track detectors (PCTD). The PCTDs were processed by 50 Hz-HV electrochemical etching using a large-size ECE chamber. The results show that helium ions produced in the APF device have a ring-shaped angular distribution peaked at an angle of ∼ ± 60 ° with respect to the top of the anode. Some information on the helium ion energy and distributions is also provided. The method is highly effective for ion beam studies.

  3. Evaluation study between the chemical and electrochemical etching for solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Ramos, S.; Espinosa, G.; Golzarri, J.I.

    1991-01-01

    Since there are several methods of etching in the solid state nuclear track detectors (SSNTD) it is necessary to know which gives the best results for a specific problem. The purpose of this work is to analyze and compare both the chemical etching and the electrochemical etching. The SSNTD has a preferential response to certain kinds of particles and energies, according to the material used as detector. On the other hand the efficiency is a function of the incidence angle of the radiation and some other parameters such as temperature, concentration and type of solvent used in the etching process, and the method used for the etching. Therefore, it is necessary to extend as much as possible our knowledge of such parameters in order to choose the more efficient one for a specific problem

  4. Procedures for the use of Lexan and Makrofol SSNTDs in the detection of environmental concentrations of 235U and 239Pu

    International Nuclear Information System (INIS)

    Henderson, C.L.

    1993-03-01

    Solid State Nuclear Track Detectors are used to study a variety of atomic particles. Polycarbonate SSNTD is used to study environmental concentrations of 235 U and 239 Pu in human urine and feces through fission track analysis. The samples of interest are deposited upon a Lexan slide, covered with a piece of Makrofol and exposed to a neutron fluence of 1.1 X 10 17 . The fissile isotopes in the sample fission and the resulting fission fragments pass through either the surface of the Lexan or the surface of the Makrofol. The positive Coulombic attraction of the ionized fission fragments causes the electrons of the polycarbonate lattice to move towards the path of these particles, resulting in the breakage of chemical bonds in the lattice. The detector is then chemically etched in 6.5 N KOH that preferentially dissolves the damaged polycarbonate left in the path of the fission fragment. The chemically etched fission tracks are permanent records of the path of the fission fragment. The etched fission tracks in Lexan are optically counted using a microscope and the fission tracks in Makrofol are counted using a Spark Chamber. The amount of fissile material in the original sample can be calculated from the number of fission tracks. This paper presents further details of procedures for etching fission tracks in Lexan and Makrofol and for operating a Spark Chamber to count etched fission tracks in Makrofol. The physics of fission track formation in dielectric detectors is also discussed, as well as the physics of the Spark Chamber

  5. Low Loss Polycarbonate Polymer Optical Fiber for High Temperature FBG Humidity Sensing

    DEFF Research Database (Denmark)

    Woyessa, Getinet; Fasano, Andrea; Markos, Christos

    2017-01-01

    We report the fabrication and characterization of a polycarbonate (PC) microstructured polymer optical fiber (mPOF) Bragg grating (FBG) humidity sensor that can operate beyond 100°C. The PC preform, from which the fiber was drawn, was produced using an improved casting approach to reduce...... the attenuation of the fiber. The fiber loss was found reduced by a factor of two compared to the latest reported PC mPOF [20], holding the low loss record in PC based fibers. PC mPOFBG was characterized to humidity and temperature, and a relative humidity (RH) sensitivity of 7.31± 0.13 pm/% RH in the range 10...

  6. Impact of electron irradiation on particle track etching response in ...

    Indian Academy of Sciences (India)

    In the present work, attempts have been made to investigate the modification in particle track etching response of polyallyl diglycol carbonate (PADC) due to impact of 2 MeV electrons. PADC samples pre-irradiated to 1, 10, 20, 40, 60, 80 and 100 Mrad doses of 2 MeV electrons were further exposed to 140 MeV 28Si beam ...

  7. The etching property of the surface of CR-39 and the track core radius of fission fragment

    CERN Document Server

    Mineyama, D; Yamauchi, T; Oda, K; El-Rahman, A

    2002-01-01

    The etch pits of fission fragments in CR-39 detector have been observed carefully using an atomic force microscope (AFM) after extremely short chemical etching in stirred 6N KOH solution kept at 70degC. It was found that there existed a thin layer where the bulk etch rate is relativity from large the etch-pit growth curve for the etching duration between 10 and 1800 seconds. The track core radius of fission fragment was evaluated to be about 6 nm from the extrapolation of the growth curve in a thinner region. (author)

  8. Nuclear particle track-etched anti-bogus mark

    International Nuclear Information System (INIS)

    He Xiangming; Yan Yushun; Zhang Quanrong

    2003-01-01

    Nuclear particle track-etched anti-bogus mark is a new type of forgery-proof product after engraving gravure printing, thermocolour, fluorescence, laser hologram and metal concealed anti-bogus mark. The mark is manufactured by intricate high technology and the state strictly controlled sensitive nuclear facilities to ensure the mark not to be copied. The pattern of the mark is specially characterized by permeability of liquid to be discriminated from forgery. The genuine mark can be distinguished from sham one by transparent liquid (e.g. water), colorful pen and chemical reagent. The mark has passed the official examination of health safety. It is no danger of nuclear irradiation. (author)

  9. Spot formation of radiation particles by electrochemical etching

    International Nuclear Information System (INIS)

    Nozaki, Tetsuya

    1999-01-01

    An electrochemical etching (ECE) spot formation from the top of chemical etching (CE) spot was confirmed by a series of experiments. One of polycarbonate (Iupilon) could not make the spot, because ECE spot had grown up before the microscope confirming the CE spot. Clear CEC spots by α-ray and neutron were found on Harzlas and Baryotrak, both improvements of CR-39. Under the same etching conditions, the growth of ECE spot on Harzlas was more rapid than Baryotrak, but both spots were almost the same. All CE spot by α-ray produced the CEC spots, but a part of CE circle spot by neutron formed them. (S.Y.)

  10. Investigation of optical properties of Cu/Ni multilayer nanowires embedded in etched ion-track template

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Lu [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Yao, Huijun, E-mail: Yaohuijun@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Duan, Jinglai; Chen, Yonghui [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Lyu, Shuangbao [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Maaz, Khan [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Nanomaterials Research Group, Physics Division, PINSTECH, Nilore 45650, Islamabad (Pakistan); Mo, Dan [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Liu, Jie, E-mail: J.Liu@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Sun, Youmei; Hou, Mingdong [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2016-12-01

    Graphical abstract: The schematic diagram of measurement of extinction spectra of Cu/Ni multilayer nanowire arrays embedded in the template after removing the gold/copper substrate. - Highlights: • The optical properties of Cu/Ni multilayer nanowire arrays were first investigated by UV/Vis/NIR spectrometer and it was confirmed that the extinction peaks strongly related to the periodicity of the multilayer nanowire. • The Ni segment was thought as a kind of impurity which can change the surface electron distribution and thereby the extinction peaks of nanowire. • Current work supplied the clear layer thickness information of Cu and Ni in Cu/Ni multilayer nanowire with TEM and EDS line-scan profile analysis. - Abstract: For understanding the interaction between light and noble/magnetism multilayer nanowires, Cu/Ni multilayer nanowires are fabricated by a multi-potential step deposition technique in etched ion-track polycarbonate template. The component and the corresponding layer thickness of multilayer nanowire are confirmed by TEM and EDS line-scan analysis. By tailoring the nanowire diameter, the Cu layer thickness and the periodicity of the nanowire, the extinction spectral of nanowire arrays exhibit an extra sensitivity to the change of structural parameters. The resonance wavelength caused by surface plasmon resonance increases obviously with increasing the nanowire diameter, the Cu layer thickness and the periodicity. The observations in our work can be explained by the “impurity effect” and coupled effect and can also be optimized for developing optical devices based on multilayer nanowires.

  11. High energy charged particle registration in CR-39 polycarbonated detector

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El Enany, N.; El Fiki, S.; Eissa, H.M.; El-Adl, E.H.; El-Feky, M.A.

    1991-01-01

    Track etch rate characteristics of CR-39 plastic detector exposed to 28 Si ions of 670 MeV energy have been investigated. Experimental results were obtained in terms of frequency distribution of the track diameter, track density and bulk etching rate. A dependence of the mean track diameter on energy was found. The application of the radiation effect of heavy ions on CR-39 in the field of radiation detection and dosimetry are discussed. Results indicated that it is possible to produce etchable tracks of 28 Si in this energy range in CR-39. We also report the etching characteristics of these tracks in the CR-39 detector. (orig.) [de

  12. Fabrication of beta-PVDF membranes by track etching and specific functionalization of nano-pores

    International Nuclear Information System (INIS)

    Cuscito, O.

    2008-01-01

    Poly(vinylidene fluoride)(β-PVDF) nano-porous membranes were made by chemical revealing of tracks induced from swift heavy ions irradiation. Pore opening and radii can be varied in a controllable manner with the etching time. nano-pores size in nano-meter scale (from 12 nm to 50 nm) appears to be linearly dependent to the etching time. It was then necessary to adapt the characterization tools to these membranes. Consequently, we resorted to the use of structural analysis methods (Scanning Electron Microscopy, Small Angle Neutron Scattering) and developed evaluation methods of the membranes transport properties like gas permeation and ionic diffusion. Results obtained confirm the pores opening (break through) and the hydrophobicity of material, which we have modified with hydrophilic molecules. In this precise case, the grafting of acrylic acid was initiated by the radicals still remains after track-etching (called radio-grafting). This key result was obtained by a study of Electron Paramagnetic Resonance. The labelling of introduced chemical functionalities with fluorescent probes was a very effective mean to visualize very few amounts of molecules by confocal microscopy. The radio-grafting was found specifically localized inside etched tracks. The protocol offers the possibility to create a double functionality, the one localized inside the nano-pores and the other on the surface of membranes. The modification of radio-grafting parameters (the acrylic acid concentration, solvent nature, use of transfer agent) and the chemical properties of the nano-pore walls have a direct incidence on the transport properties. (author) [fr

  13. Photoluminescent study of Polycarbonate (PC) and Poly(9-vinylcarbazole) (PVK) doped films with europium complex; Estudo fotoluminescente de filmes de Policarbonato (PC) e Poli(9-vinilcarbazol) (PVK) dopados com complexo de europio

    Energy Technology Data Exchange (ETDEWEB)

    Forster, Pedro Lima

    2010-07-01

    Polymers doped with rare earth complexes are advantaged in film production for many applications in the luminescent field. In this study luminescent polymer obtained from polycarbonate (PC) and poly(9-vinylcarbazole) films doped with diaquatris(thenoyltrifluoroacetonate)europium(III) complex [Eu(tta){sub 3}(H{sub 2}0){sub 2}] were prepared and their calorimetric and luminescent properties in the solid state are reported. The thermal behavior was investigated by differential scanning calorimetry (OSC) and thermogravimetry analysis (TGA). Due of the addition of rare earth Eu(tta){sub 3}(H{sub 2}0){sub 2}] into PC and PVK matrices, changes were observed in the thermal behavior concerning the glass transition and thermal stability. Characteristic broadened narrow bands arising from the {sup 5}D{sub 0} -{yields} {sup 7}F{sub J} transitions (J = 0-4) of Eu{sup 3+} ion indicate the incorporation of the Eu{sup 3+} ions into those polymers. The luminescent films show enhancement emission intensity with an increase in the rare earth concentration in polymeric matrix accompanied by decrease in thermal stability. (author)

  14. CERN Physics Screen Saver: Help LHC tracking studies on your PC

    CERN Multimedia

    2004-01-01

    Many PC users are familiar with screensavers such as SETI@home and FightAIDS@home. These screensavers take advantage of times when your PC is idle to do useful computing on a particular scientific problem. SETI@home, which analyses radio-astronomy data for signs of extraterrestrial intelligence, has been downloaded by over 5 million people. Similar programs are now sold commercially, and installed in major corporations to provide extra computing power at low cost. CERN 's IT Department is interested in evaluating this sort of technology for the future. Most of the scientific computing challenges that the LHC experiments are facing will require access to large amounts of storage, and cannot be run on individual PCs. However, there are exceptions. A program called SixTrack, which simulates particles traveling around the LHC to study the stability of their orbits, can fit on a single PC and requires relatively little input or output. SixTrack, which was developed by Frank Schmidt of the AB Department, produces r...

  15. Fabrication and characterization of polycarbonate microstructured polymer optical fibers for high-temperature-resistant fiber Bragg grating strain sensors

    DEFF Research Database (Denmark)

    Fasano, Andrea; Woyessa, Getinet; Stajanca, Pavol

    2016-01-01

    Here we present the fabrication of a solid-core microstructured polymer optical fiber (mPOF) made of polycarbonate (PC), and report the first experimental demonstration of a fiber Bragg grating (FBG) written in a PC optical fiber. The PC used in this work has a glass transition temperature of 145°C...

  16. A novel approach to particle track etching: surfactant enhanced control of pore morphology

    International Nuclear Information System (INIS)

    Apel', P.Yu.; Dmitriev, S.N.; Vutsadakis, V.A.; Root, D.

    2000-01-01

    Based on the understanding of the mechanism behind a long observed but thus far unexplained effect, a new method to control the geometry of nano- and micropores is described. Surfactant molecules added to an etching solution used for etching out ion tracks, create a steric-hindrance effect which is responsible for the formation of 'bottleneck' or 'cigar-like' pores. Filtration membranes thus obtained exhibit significantly improved flow rates without deterioration in the retention properties. New applications are made possible with these new pore geometries

  17. Track etch detectors with air gap for measurements of radon in soil

    Energy Technology Data Exchange (ETDEWEB)

    Turek, K; Bednar, J [Czech Academy of Sciences, 18086 Prague (Czech Republic). Nuclear Research Inst., Dept. of Radiation Dosimetry; Neznal, M [Radon Corp., 28922 Lysa nad Labem (Czech Republic)

    1996-12-31

    The main aim of this study was to develop a method of radon concentration measurements in soil using track etch detectors without cups. Our approach enables to minimize the detector dimensions resulting into smaller diameter of drilled holes, more rigid construction, easier handling and mailing, lower consumption of material and consequently in lower costs. The parallel arrangement of two track etch detectors in the open metallic holder seems to be promising as the complementary method to the commonly used cup-technique for radon measurement. The firmness, simple and compact construction, small size as well as low costs could be successfully utilized mainly in field measurement. The possibility of a variable sensitivity by the distance between the detectors makes the system versatile for many applications, 2 detectors with different h can practically exclude of under- or overexposure. The more precise calibrations including exposures in radon-chamber and study of an eventual influence of humidity are supposed to be done in the nearest future. (J.K) 2 tabs.

  18. Anti-biofilm activity of Fe heavy ion irradiated polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, R.P. [Department of Physics, Savitribai Phule Pune University, Pune 411007 (India); Hareesh, K., E-mail: appi.2907@gmail.com [Department of Physics, Savitribai Phule Pune University, Pune 411007 (India); Bankar, A. [Department of Microbiology, Waghire College, Pune 412301 (India); Sanjeev, Ganesh [Microtron Centre, Department of Studies in Physics, Mangalore University, Mangalore 574166 (India); Asokan, K.; Kanjilal, D. [Inter University Accelerator Centre, Arun Asaf Ali Marg, New Delhi 110067 (India); Dahiwale, S.S.; Bhoraskar, V.N. [Department of Physics, Savitribai Phule Pune University, Pune 411007 (India); Dhole, S.D., E-mail: sanjay@physics.unipune.ac.in [Department of Physics, Savitribai Phule Pune University, Pune 411007 (India)

    2016-10-01

    Highlights: • PC films were irradiated by 60 and 120 MeV Fe ions. • Irradiated PC films showed changes in its physical and chemical properties. • Irradiated PC also showed more anti-biofilm activity compared to pristine PC. - Abstract: Polycarbonate (PC) polymers were investigated before and after high energy heavy ion irradiation for anti-bacterial properties. These PC films were irradiated by Fe heavy ions with two energies, viz, 60 and 120 MeV, at different fluences in the range from 1 × 10{sup 11} ions/cm{sup 2} to 1 × 10{sup 13} ions/cm{sup 2}. UV-Visible spectroscopic results showed optical band gap decreased with increase in ion fluences due to chain scission mainly at carbonyl group of PC which is also corroborated by Fourier transform infrared spectroscopic results. X-ray diffractogram results showed decrease in crystallinity of PC after irradiation which leads to decrease in molecular weight. This is confirmed by rheological studies and also by differential scanning calorimetric results. The irradiated PC samples showed modification in their surfaces prevents biofilm formation of human pathogen, Salmonella typhi.

  19. Some characteristics of the AEOI [Atomic Energy Organisation of Iran] passive radon diffusion dosimeter

    International Nuclear Information System (INIS)

    Sohrabi, M.; Solaymanian, A.R.

    1988-01-01

    A passive radon diffusion dosimeter was developed for large-scale radon level measurements in Iran. It consists of a plastic cup with a polycarbonate alpha detector in the middle, a plastic tip cover with an opening holding a fiberglass filter and a hard aluminium mesh for protection and support. A new design for our multi-chamber electro-chemical etching (ECE) system was used for multiple foil etching. The effects of pre-etching and ECE times, chamber volume, filter diameter and foil position inside the chamber were investigated. The optimized geometries included 9.5 cm height, 296 cm 3 volume and 2-3 cm filter diameter with the PC foil mounted in the middle. A sensitivity of 0.05±0.007 tracks.cm -2 /Bq.m -3 .day or 1.86±0.28 tracks.cm -2 /pCi.1 -1 .day was obtained at optimized conditions. In this paper, the design and the characteristics of the dosimeter as well as some results of the optimization studies are reported and discussed. (author)

  20. Gamma radiation effects on polycarbonate-Durolon

    International Nuclear Information System (INIS)

    Miranda, Adelina.

    1996-01-01

    In this work, the commercial polycarbonate-Durolon, was characterized through measurements of its mechanical, optical viscosimetric and thermal properties, after being irradiated with a 60 Co gamma-source at IPEN-CNEN/SP. These irradiations were carried out different doses and dose rates in air and in vacuum. From the results obtained it was shown that irradiation causes degradation in PC mainly by chain scission, leading to the formation of phenoxy and phenyl radicals which are associated with the yellowness of the material. Both, the concentration of radicals and yellowness of PC increase with the irradiation doses and dose rates. The irradiated PC-Durolon shown a good mechanical stability up to the doses analyzed, but on the other hand, its optical properties do not have the same performance. The viscosity and glass transition temperature of the Durolon decreases with the increase of dose and dose rates. This behavior indicates that main chain scission is the predominant process during irradiation. Furthermore in PC this degradation is higher when the material is irradiated in air, which shows that oxygen also plays an important role in this degradation process. (author). 37 refs., 30 figs., 4 tabs

  1. On crystallization of bisphenol-A polycarbonate thin films upon annealing

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chunhong; Li, Qichao; Mao, Wenfeng; Wang, Peng; He, Chunqing, E-mail: hecq@whu.edu.cn

    2015-10-16

    Crystallization of polycarbonate (PC) films as a function of annealing time has been investigated by various methods. A distinct diffraction peak at 17.56°, a sharp decrease of film thickness, an increase of refractive index and branch-type structures on the surface are found merely for the film after crystallization. Interestingly, positron annihilation parameters demonstrate fractional free-volumes in PC films vary significantly not only before crystallization but also at the early stage of annealing, which are not found by other methods. The results show that free-volumes in PC film must be increased remarkably before crystallization, which enables the occurrence of molecule rearrangement. - Highlights: • Fractional free-volume in PC film decreased of early stage of annealing. • Crystallization of PC film on Si substrate occurred after annealed for ∼48 hours. • Fractional free-volume in PC film increased remarkably before crystallization. • Positron diffusion length and S parameter revealed the variation of free volumes.

  2. On crystallization of bisphenol-A polycarbonate thin films upon annealing

    International Nuclear Information System (INIS)

    Yang, Chunhong; Li, Qichao; Mao, Wenfeng; Wang, Peng; He, Chunqing

    2015-01-01

    Crystallization of polycarbonate (PC) films as a function of annealing time has been investigated by various methods. A distinct diffraction peak at 17.56°, a sharp decrease of film thickness, an increase of refractive index and branch-type structures on the surface are found merely for the film after crystallization. Interestingly, positron annihilation parameters demonstrate fractional free-volumes in PC films vary significantly not only before crystallization but also at the early stage of annealing, which are not found by other methods. The results show that free-volumes in PC film must be increased remarkably before crystallization, which enables the occurrence of molecule rearrangement. - Highlights: • Fractional free-volume in PC film decreased of early stage of annealing. • Crystallization of PC film on Si substrate occurred after annealed for ∼48 hours. • Fractional free-volume in PC film increased remarkably before crystallization. • Positron diffusion length and S parameter revealed the variation of free volumes

  3. Miscibility evolution of polycarbonate/polystyrene blends during compounding

    DEFF Research Database (Denmark)

    Chuai, Chengzhi; Almdal, Kristoffer; Johannsen, Ib

    2002-01-01

    The miscibility evolution of polycarbonate/polystyrene (PC/PS) blends during the compounding process in three blending methods of industrial relevance, namely melt blending, remelt blending in a twin-screw extruder and third melt blending in an injection molding machine, was investigated...... polymer in the other. The observed solubility strongly depends on blend composition and blending method. The T-g measurements showed maximum mutual solubility around 50/50 composition. The miscibility of PC/PS blended after the third stage (melt injection molding) was higher than that after the first...... by measuring their glass transition temperatures (T-g) and their specific heat increment (DeltaC(p)). Differential scanning calorimetry (DSC) was used to examine nine blend compositions. Shifts in glass transition temperature (T-g) of the two phases in melt-mixed PC/PS blends suggest partial miscibility of one...

  4. Computer image analysis of etched tracks from ionizing radiation

    Science.gov (United States)

    Blanford, George E.

    1994-01-01

    I proposed to continue a cooperative research project with Dr. David S. McKay concerning image analysis of tracks. Last summer we showed that we could measure track densities using the Oxford Instruments eXL computer and software that is attached to an ISI scanning electron microscope (SEM) located in building 31 at JSC. To reduce the dependence on JSC equipment, we proposed to transfer the SEM images to UHCL for analysis. Last summer we developed techniques to use digitized scanning electron micrographs and computer image analysis programs to measure track densities in lunar soil grains. Tracks were formed by highly ionizing solar energetic particles and cosmic rays during near surface exposure on the Moon. The track densities are related to the exposure conditions (depth and time). Distributions of the number of grains as a function of their track densities can reveal the modality of soil maturation. As part of a consortium effort to better understand the maturation of lunar soil and its relation to its infrared reflectance properties, we worked on lunar samples 67701,205 and 61221,134. These samples were etched for a shorter time (6 hours) than last summer's sample and this difference has presented problems for establishing the correct analysis conditions. We used computer counting and measurement of area to obtain preliminary track densities and a track density distribution that we could interpret for sample 67701,205. This sample is a submature soil consisting of approximately 85 percent mature soil mixed with approximately 15 percent immature, but not pristine, soil.

  5. Grafting of acrylic acid on etched latent tracks induced by swift heavy ions on polypropylene films

    International Nuclear Information System (INIS)

    Mazzei, R.; Fernandez, A.; Garcia Bermudez, G.; Torres, A.; Gutierrez, M.C.; Magni, M.; Celma, G.; Tadey, D.

    2008-01-01

    In order to continue with a systematic study that include different polymers and monomers, the residual active sites produced by heavy ion beams, that remain after the etching process, were used to start the grafting process. To produce tracks, foils of polypropylene (PP) were irradiated with 208 Pb of 25.62 MeV/n. Then, these were etched and grafted with acrylic acid (AA) monomers. Experimental curves of grafting yield as a function of grafting time with the etching time as a parameter were measured. Also, the grating yield as a function of the fluence and etching time was obtained. In addition, the permeation of solutions, with different pH, through PP grafted foils was measured

  6. Calculation of bulk etch rate’s semi-empirical equation for polymer track membranes in stationary and dynamic modes

    Directory of Open Access Journals (Sweden)

    A. Mashentseva

    2013-05-01

    Full Text Available One of the most urgent and extremely social problems in environmental safeties area in Kazakhstan is providing the population of all regions of the country with quality drinking water. Development of filter elements based on nuclear track-etch membranes may be considered as one of best solutions this problem. The values of bulk etch rate and activation energy were calculated in view the effect of temperature, alkaline solution concentration as well as stirring effect. The semi-empirical equation of the bulk etch rate for PET track membranes was calculated. As a result of theoretical and experimental studies a semi-empirical equation of the bulk etch rate VB=3.4∙1012∙C2.07∙exp(-0.825/kT for 12 microns PET film, irradiated by ions 84Kr15+ (energy of 1.75 MeV/nucleon at the heavy ion accelerator DC-60 in Astana branch of the INP NNC RK, was obtained. 

  7. ZnO/Al{sub 2}O{sub 3} coatings for the photoprotection of polycarbonate

    Energy Technology Data Exchange (ETDEWEB)

    Moustaghfir, A. [Laboratoire des Materiaux Inorganiques, UMR CNRS 6002, Universite Blaise Pascal (Clermont-Fd), 63177 Aubiere Cedex (France); Tomasella, E. [Laboratoire des Materiaux Inorganiques, UMR CNRS 6002, Universite Blaise Pascal (Clermont-Fd), 63177 Aubiere Cedex (France); Jacquet, M. [Laboratoire des Materiaux Inorganiques, UMR CNRS 6002, Universite Blaise Pascal (Clermont-Fd), 63177 Aubiere Cedex (France)]. E-mail: jacquet@chimie.univ-bpclermont.fr; Rivaton, A. [Laboratoire de Photochimie Moleculaire et Macromoleculaire, UMR CNRS 6505, Universite Blaise Pascal (Clermont-Fd), 63177 Aubiere Cedex (France); Mailhot, B. [Laboratoire de Photochimie Moleculaire et Macromoleculaire, UMR CNRS 6505, Universite Blaise Pascal (Clermont-Fd), 63177 Aubiere Cedex (France); Gardette, J.L. [Laboratoire de Photochimie Moleculaire et Macromoleculaire, UMR CNRS 6505, Universite Blaise Pascal (Clermont-Fd), 63177 Aubiere Cedex (France); Beche, E. [PROMES, Odeillo, 66125 Font-Romeu Cedex (France)

    2006-10-25

    ZnO and ZnO/Al{sub 2}O{sub 3} thin films were deposited by r.f. magnetron sputtering on polycarbonate (PC) films in order to protect this polymer against photodegradation. The composition, structure and optical properties of the ceramic coatings were characterised. CO{sub 2}-plasma treatments were applied to PC in order to improve the coating adhesion. The PC surface energy was characterised by wettability measurements and the chemical bonds were analysed by XPS. It was found that ZnO coatings improve the stability of PC to UV radiations and that an intermediate alumina coating inhibits the photocatalytic oxidation of PC at the PC/ZnO interface. Additionally an external alumina coating brings a high hardness to the coating.

  8. Attachment and spreadout study of 3T3 cells onto PP track etched films

    International Nuclear Information System (INIS)

    Smolko, Eduardo; Mazzei, Ruben; Tadey, Daniel; Lombardo, Daniel

    2001-01-01

    Polymer surface modifications are obtained by the application of radiation treatments and other physico-chemical methods: fission fragment (ff) irradiation and etching. The biocompatibility of the surface is then observed by cell seeding and cell adhesion experiments. Approaches to improvement of the cell adhesion are obtained by different methods: for example, in PS, cell adhesion is improved after ion implantation; in PMMA, after bombarding the polymer, the surface is reconditioned with surfactants and proteins and in PVDF, cell adhesion is assayed on nuclear tracks membranes. In this work, we obtained important cell adhesion improvements in PP films by irradiation with swift heavy ions and subsequent etching of the nuclear tracks. We use BOPP (isotactic -25 μm thickness). Irrradiations were performed with a Cf-252 californium ff source. The source has a heavy ff and a light one, with 160-200 MeV energy divided among them corresponding to ff energies between 1 and 2 MeV/amu. A chemical etching procedure consisting of a solution of sulphuric acid and chromium three oxide at 85 deg. C was used. The 3T3 NIH fibroblast cell line was used for the cell adhesion experiment. Here we report for the first time, the results of a series of experiments by varying the ff fluence and the etching time showing that attachment and spreadout of cells are very much improved in this cell line according to the number of pores and the pore size

  9. Computational and experimental study of nanoporous membranes for water desalination and decontamination.

    Energy Technology Data Exchange (ETDEWEB)

    Hickner, Michael A. (Penn State University, University Park, PA); Chinn, Douglas Alan (Sandia National Laboratories, Albuquerque, NM); Adalsteinsson, Helgi; Long, Kevin R. (Texas Tech University, Lubbock, TX); Kent, Michael Stuart (Sandia National Laboratories, Albuquerque, NM); Debusschere, Bert J.; Zendejas, Frank J.; Tran, Huu M.; Najm, Habib N.; Simmons, Blake Alexander

    2008-11-01

    Fundamentals of ion transport in nanopores were studied through a joint experimental and computational effort. The study evaluated both nanoporous polymer membranes and track-etched nanoporous polycarbonate membranes. The track-etched membranes provide a geometrically well characterized platform, while the polymer membranes are more closely related to ion exchange systems currently deployed in RO and ED applications. The experimental effort explored transport properties of the different membrane materials. Poly(aniline) membranes showed that flux could be controlled by templating with molecules of defined size. Track-etched polycarbonate membranes were modified using oxygen plasma treatments, UV-ozone exposure, and UV-ozone with thermal grafting, providing an avenue to functionalized membranes, increased wettability, and improved surface characteristic lifetimes. The modeling effort resulted in a novel multiphysics multiscale simulation model for field-driven transport in nanopores. This model was applied to a parametric study of the effects of pore charge and field strength on ion transport and charge exclusion in a nanopore representative of a track-etched polycarbonate membrane. The goal of this research was to uncover the factors that control the flux of ions through a nanoporous material and to develop tools and capabilities for further studies. Continuation studies will build toward more specific applications, such as polymers with attached sulfonate groups, and complex modeling methods and geometries.

  10. Fluorinated copper-phthalocyanine-based n-type organic field-effect transistors with a polycarbonate gate insulator

    International Nuclear Information System (INIS)

    Sethuraman, Kunjithapatham; Kumar, Palanisamy; Santhakumar, Kannappan; Ochiai, Shizuyasu; Shin, Paikkyun

    2012-01-01

    Fluorinated copper-phthalocyanine (F 16 CuPc) thin films were prepared by using a vacuum evaporation technique and were applied to n-type organic field-effect transistors (OFETs) as active channel layers combined with a spin-coated polycarbonate thin-film gate insulator. The output characteristics of the resulting n-type OFET devices with bottom-gate/bottom-contact structures were investigated to evaluate the performances such as the field effect mobility (μ FE ), the on/off current ratio (I on/off ), and the threshold voltage (V th ). A relatively high field effect mobility of 6.0 x 10 -3 cm 2 /Vs was obtained for the n-type semiconductor under atmospheric conditions with an on/off current ratio of 1 x 10 4 and a threshold voltage of 5 V. The electron mobility of the n-type semiconductor was found to depend strongly on the growth temperature of the F 16 CuPc thin films. X-ray diffraction profiles showed that the crystallinity and the orientation of the F 16 CuPc on a polycarbonate thin film were enhanced with increasing growth temperature. Atomic force microscopy studies revealed various surface morphologies of the active layer. The field effect mobility of the F 16 CuPc-OFET was closely related to the crystallinity and the orientation of the F 16 CuPc thin film.

  11. Thermal degradation kinetics and lifetime estimation for polycarbonate/polymethylphenylsilsesquioxane composite

    Institute of Scientific and Technical Information of China (English)

    Jiangbo WANG; Zhong XIN

    2009-01-01

    The thermal degradation behaviors of poly-carbonate/polymethylphenylsilsesquioxane (FRPC) composites were investigated by thermogravimetric analysis (TGA) under isothermal conditions in nitrogen atmosphere. The isothermal kinetics equation was used to describe the thermal degradation process. The results showed that activation energy (E), in the case of isothermal degradation, was a quick increasing function of conversion (a) for polycarbonate (PC) but was a strong and decreasing function of conversion for FRPC. Under the isothermal condition, the addition of polymethylphenylsilsesquioxane (PMPSQ) retardanted the thermal degradation and enhanced the thermal stability of PC during the early and middle stages of thermal degradation. It also indicated a possible existence of a difference in nucleation, nuclei growth, and gas diffusion mechanism in the thermal degradation process between PC and FRPC. Meanwhile, the addition of PMPSQ influenced the lifetime of PC, but the composite still met the demand in manufacturing and application.

  12. Track-etched detectors for the dosimetry of the radiation of cosmic origin

    Czech Academy of Sciences Publication Activity Database

    Spurný, František; Turek, Karel

    2004-01-01

    Roč. 109, č. 4 (2004), s. 375-381 ISSN 0144-8420 R&D Projects: GA AV ČR KSK4055109 Grant - others:EC project(XE) FIGM-CT2000-00068 Institutional research plan: CEZ:AV0Z1048901 Keywords : track-etched detectors * cosmic rays * aircraft Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.617, year: 2003

  13. The use of CH3OH additive to NaOH for etching alpha particle tracks in a CR-39 plastic nuclear track detector

    International Nuclear Information System (INIS)

    Ashry, A.H.; Abdalla, A.M.; Rammah, Y.S.; Eisa, M.; Ashraf, O.

    2014-01-01

    Fast detection of alpha particles in CR-39 detectors was investigated using a new chemical etchant. 252 Cf and 241 Am sources were used for irradiating samples of CR-39 SSNTDs with fission fragments and alpha particles in air at normal temperature and pressure. A series of experimental chemical etching are carried out using new etching solution (8 ml of 10N NaOH+1 ml CH 3 OH) at 60 °C to detect alpha particle in short time in CR-39 detectors. Suitable analyzing software has been used to analyze experimental data. From fission and alpha track diameters, the value of bulk etching rate is equal to 2.73 μm/h. Both the sensitivity and etching efficiency were found to vary with the amount of methanol in the etching solution. Pure NaOH was used as a control to compare with the result from etching in NaOH with different concentrations of CH 3 OH. The etching efficiency is determined and compared with conventional aqueous solution of 6.25N NaOH at 70 °C for etching time equals 5 h. In this study, the obtained etching efficiency shows a considerable agreement with the previous work. - Highlights: • The value of bulk etching rate is equal to 2.73 μm/h. • Fast detection of alpha particles in CR-39 detectors. • Samples of CR-39 have been irradiated with fission fragments. • Etching efficiency was determined

  14. Scratch resistance of a polycarbonate + organoclay nanohybrid

    Directory of Open Access Journals (Sweden)

    2009-10-01

    Full Text Available A polycarbonate-based nanohybrid has been created containing 1 wt% of Bentone 2010, an organically modified montmorillonite. A micro-section on the nanohybrid obtained using focused ion beam (FIB and field emission scanning electron microscopy (FESEM was employed to observe the orientation of the nanoclay inside a polycarbonate (PC matrix in the cross-section FIB-milled face. A micro-scratch tester was used to measure the scratch resistance in terms of residual (healing depth Rh under progressive load and in sliding wear. Effects of the number of scratches, normal load and scratch velocity have been evaluated as a function of nanoclay orientation. In sliding wear (multiple scratching along the same groove, our nanohybrid reaches residual depth values that remain constant after a certain number of scratches, a manifestation of strain hardening. The number of scratches to induce strain hardening decreases as the normal applied load increases. SEM was used to characterize deformation and wear mechanisms that operate on contacts and the results related to the wear data.

  15. Hierarchically porous carbon membranes containing designed nanochannel architectures obtained by pyrolysis of ion-track etched polyimide

    International Nuclear Information System (INIS)

    Muench, Falk; Seidl, Tim; Rauber, Markus; Peter, Benedikt; Brötz, Joachim; Krause, Markus; Trautmann, Christina; Roth, Christina; Katusic, Stipan; Ensinger, Wolfgang

    2014-01-01

    Well-defined, porous carbon monoliths are highly promising materials for electrochemical applications, separation, purification and catalysis. In this work, we present an approach allowing to transfer the remarkable degree of synthetic control given by the ion-track etching technology to the fabrication of carbon membranes with porosity structured on multiple length scales. The carbonization and pore formation processes were examined with Raman, Brunauer–Emmett–Teller (BET), scanning electron microscopy (SEM) and X-ray diffraction (XRD) measurements, while model experiments demonstrated the viability of the carbon membranes as catalyst support and pollutant adsorbent. Using ion-track etching, specifically designed, continuous channel-shaped pores were introduced into polyimide foils with precise control over channel diameter, orientation, density and interconnection. At a pyrolysis temperature of 950 °C, the artificially created channels shrunk in size, but their shape was preserved, while the polymer was transformed to microporous, amorphous carbon. Channel diameters ranging from ∼10 to several 100 nm could be achieved. The channels also gave access to previously closed micropore volume. Substantial surface increase was realized, as it was shown by introducing a network consisting of 1.4 × 10 10 channels per cm 2 of 30 nm diameter, which more than tripled the mass-normalized surface of the pyrolytic carbon from 205 m 2  g −1 to 732 m 2  g −1 . At a pyrolysis temperature of 3000 °C, membranes consisting of highly ordered graphite were obtained. In this case, the channel shape was severely altered, resulting in a pronounced conical geometry in which the channel diameter quickly decreased with increasing distance to the membrane surface. - Highlights: • Pyrolysis of ion-track etched polyimide yields porous carbon membranes. • Hierarchic porosity: continuous nanochannels embedded in a microporous carbon matrix. • Freely adjustable meso- or

  16. Hierarchically porous carbon membranes containing designed nanochannel architectures obtained by pyrolysis of ion-track etched polyimide

    Energy Technology Data Exchange (ETDEWEB)

    Muench, Falk, E-mail: muench@ca.tu-darmstadt.de [Department of Material- and Geoscience, Technische Universität Darmstadt, Alarich-Weiss-Straße 2, 64287 Darmstadt (Germany); Seidl, Tim; Rauber, Markus [Department of Material- and Geoscience, Technische Universität Darmstadt, Alarich-Weiss-Straße 2, 64287 Darmstadt (Germany); Material Research Department, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt (Germany); Peter, Benedikt; Brötz, Joachim [Department of Material- and Geoscience, Technische Universität Darmstadt, Alarich-Weiss-Straße 2, 64287 Darmstadt (Germany); Krause, Markus; Trautmann, Christina [Department of Material- and Geoscience, Technische Universität Darmstadt, Alarich-Weiss-Straße 2, 64287 Darmstadt (Germany); Material Research Department, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt (Germany); Roth, Christina [Department of Chemistry and Biochemistry, Freie Universität Berlin, Takustraße 3, 14195 Berlin (Germany); Katusic, Stipan [Evonik Industries AG, Rodenbacher Chaussee 4, 63457 Hanau (Germany); Ensinger, Wolfgang [Department of Material- and Geoscience, Technische Universität Darmstadt, Alarich-Weiss-Straße 2, 64287 Darmstadt (Germany)

    2014-12-15

    Well-defined, porous carbon monoliths are highly promising materials for electrochemical applications, separation, purification and catalysis. In this work, we present an approach allowing to transfer the remarkable degree of synthetic control given by the ion-track etching technology to the fabrication of carbon membranes with porosity structured on multiple length scales. The carbonization and pore formation processes were examined with Raman, Brunauer–Emmett–Teller (BET), scanning electron microscopy (SEM) and X-ray diffraction (XRD) measurements, while model experiments demonstrated the viability of the carbon membranes as catalyst support and pollutant adsorbent. Using ion-track etching, specifically designed, continuous channel-shaped pores were introduced into polyimide foils with precise control over channel diameter, orientation, density and interconnection. At a pyrolysis temperature of 950 °C, the artificially created channels shrunk in size, but their shape was preserved, while the polymer was transformed to microporous, amorphous carbon. Channel diameters ranging from ∼10 to several 100 nm could be achieved. The channels also gave access to previously closed micropore volume. Substantial surface increase was realized, as it was shown by introducing a network consisting of 1.4 × 10{sup 10} channels per cm{sup 2} of 30 nm diameter, which more than tripled the mass-normalized surface of the pyrolytic carbon from 205 m{sup 2} g{sup −1} to 732 m{sup 2} g{sup −1}. At a pyrolysis temperature of 3000 °C, membranes consisting of highly ordered graphite were obtained. In this case, the channel shape was severely altered, resulting in a pronounced conical geometry in which the channel diameter quickly decreased with increasing distance to the membrane surface. - Highlights: • Pyrolysis of ion-track etched polyimide yields porous carbon membranes. • Hierarchic porosity: continuous nanochannels embedded in a microporous carbon matrix.

  17. Monte Carlo simulations of radioactive waste encapsulated by bisphenol-A polycarbonate and effect of bismuth-III oxide filler material

    International Nuclear Information System (INIS)

    Özdemir, Tonguç

    2017-01-01

    Radioactive waste generated from the nuclear industry and non-power applications should carefully be treated, conditioned and disposed according to the regulations set by the competent authority(ies). Bisphenol-a polycarbonate (BPA-PC), a very widely used polymer, might be considered as a potential candidate material for low level radioactive waste encapsulation. In this work, the dose rate distribution in the radioactive waste drum (containing radioactive waste and the BPA-PC polymer matrix) was determined using Monte Carlo simulations. Moreover, the change of mechanical properties of BPA-PC was estimated and their variation within the waste drum was determined for the periods of 15, 30 and 300 years after disposal to the final disposal site. The change of the dose rate within the waste drum with different contents of bismuth-III oxide were also simulated. It was concluded that addition of bismuth-III oxide filler decreases the dose delivered to the polymeric matrix due to photoelectric effect. - Highlights: • Bisphenol-a polycarbonate (BPA-PC) is a widely used polymeric material and have a considerable gamma radiation stability. • BPA-PC could have a potential candidate material for radioactive waste embedding. • Activity of the radioactive waste that could be embedded into the BPA-PC matrix was simulated. • Effect of bismuth-III-oxide filler to the BPA-PC matrix was determined.

  18. Effect of ZnO nano in the blend PET / PC ( 80/20) subjected to UV radiation; Efeito do nano ZnO na mistura PET/PC(80/20) submetida a radiacao UV

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Homero M.; Mendes, Luis C.; Albitres, Gerson A.V.; Cestari, Sibele P.; Mattos, Gabriela C., E-mail: homero@ima.ufrj.br [Universidade Federal do Rio de Janeiro (IMA/UFRJ), Rio de Janeiro, RJ (Brazil). Instituto de Macromoleculas Professora Eloisa Mano

    2015-07-01

    The aim of this research was to reuse recycled poly(ethylene terephthalate) (PET) in blend with polycarbonate (PC) in order to avoid UV degradation in outdoor application. Nanocomposite based on blend of recycled (PET) and polycarbonate (PC) in the ratio of 80/20 with nano zinc oxide (ZnO) at different concentrations was prepared. The blend was subjected to ultraviolet (UV) radiation for accelerated aging chamber, we evaluated the effect of the presence nZnO filler as a barrier to UV rays. Dynamic-mechanical analysis (DMA) and nuclear magnetic resonance in the solid state (NMR). It is the degradation retardant effect at concentrations starting from 3% nZnO. (author)

  19. Method to improve the evaluation of a combination track-etch dosimeter/spectrometer

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Parkhurst, M.A.; Hadlock, D.E.; Faust, L.G.

    1983-09-01

    A paper is summarized which describes a method of determining the neutron energy spectrum through spectrum unfolding techniques to more accurately assess the dose equivalent from track-etch dosimeters. A mathematical technique is described which can be used in conjunction with the neutron detectors to more accurately estimate neutron dose equivalent. The technique is based upon solutions to a system of Fredholm integral equations of the first type

  20. Coupled chemical reactions in dynamic nanometric confinement: Ag2O membrane formation during ion track etching

    Czech Academy of Sciences Publication Activity Database

    Hernandez, G. M.; Cruz, S. A.; Quintero, R.; Arellano, H. G.; Fink, Dietmar; Alfonta, L.; Mandabi, Y.; Kiv, A.; Vacík, Jiří

    2013-01-01

    Roč. 168, č. 9 (2013), s. 675-695 ISSN 1042-0150 Institutional support: RVO:61389005 Keywords : track * polymers * etching * chemistry * ions * nanostructure Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.603, year: 2013

  1. Plasma surface modification of polypropylene track-etched membrane to improve its performance properties

    Science.gov (United States)

    Kravets, L. I.; Elinson, V. M.; Ibragimov, R. G.; Mitu, B.; Dinescu, G.

    2018-02-01

    The surface and electrochemical properties of polypropylene track-etched membrane treated by plasma of nitrogen, air and oxygen are studied. The effect of the plasma-forming gas composition on the surface morphology is considered. It has been found that the micro-relief of the membrane surface formed under the gas-discharge etching, changes. Moreover, the effect of the non-polymerizing gas plasma leads to formation of oxygen-containing functional groups, mostly carbonyl and carboxyl. It is shown that due to the formation of polar groups on the surface and its higher roughness, the wettability of the plasma-modified membranes improves. In addition, the presence of polar groups on the membrane surface layer modifies its electrochemical properties so that conductivity of plasma-treated membranes increase.

  2. Study of α-energy discrimination in CR-39 track etch detectors for use as a radon/thoron dosemeter

    International Nuclear Information System (INIS)

    Kandaiya, S.; Al-Najjar, S.A.R.; Piesch, E.

    1988-01-01

    The properties of CR 39 nuclear track detectors were evaluated for their α-energy discrimination up to 8.77 MeV using a combination of chemical-electrochemical track revealing techniques. Using three field strengths, α-energy discrimination by ECE track diameter and track density as a function of chemical pre-etching time were studied. α-energy spectra using different irradiation geometries were then evaluated using the optimum conditions and then compared with those obtained form other techniques. (author)

  3. Operational comparison of TLD albedo dosemeters and etched-track detectors in the PuO2-UO2 mixed oxide fuel fabrication facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Takada, C.; Yoshida, T.; Momose, T.

    2005-01-01

    Full text: The authors carried out an operational study that compared the use of TLD albedo dosemeters with etched-track detector in plutonium environments of Japan Nuclear Cycle Development Institute, Tokai Works. A selected group of workers engaged in the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel wore both TLD albedo dosemeters and etched-track detectors over a period from 1991 to 1993. The TLD albedo dosemeter is the Panasonic model UD-809P and the etched-track detector is the NEUTRAK (polyallyl diglycol carbonate + 1mm-t polyethylene radiator) commercially available from Nagase-Landauer Ltd. Both dosemeters were issued and read monthly. It was found that the TL readings were generally proportional to the counted etch-pits, and thus the dose equivalent results obtained from TLD albedo dosemeter agreed with those from etched-track detector within a factor of 1.5. This result indicates that, in the workplaces of the MOX plants, the neutron spectrum remained almost constant in terms of time and space, and the appropriate range of field-specific correction with spectrum variations could be small in albedo dosimetry. In addition, the calibrations of both dosemeters in the workplaces and in a bare and moderated 252 Cf calibration field were performed for quantitative validation for the results from the operational comparison. In the former experiments, locations were selected that were representative of typical neutron measurements according to the prior neutron spectra measurements with the multi-sphere spectrometer. In the latter experiments, the workplace environments were simulated by using a 252 Cf source surrounded with cylindrical steel/PMMA moderators. From both experiments, the relationship between TL readings and counted etch-pits with neutron spectrum variation was determined. As expected, the relationship obtained from the simulated workplace field calibration reproduced that from the operational comparison. (author)

  4. Isobaric PVT Behavior of Poly(Carbonate) (PC)

    Science.gov (United States)

    Grassia, Luigi; D'Amore, Alberto

    2010-06-01

    The scaling law for relaxation times, τ(V,T) = ℑ(TVγ), recently proposed by Casalini and Roland, is utilized in the framework of KAHR (Kovacs Aklonis Hutchinson and Ramos) phenomenological theory. With this approach it is shown that the Pressure, Volume, Temperature (PVT) data obtained on Poly(carbonate)(PC) can be reliably predicted, in the region of the alpha relaxation, by using only two fitting parameters, namely: the relaxation time in the reference condition, τg, and the fractional exponent, β that describes the dispersion of the alpha relaxation.

  5. Model calculations for electrochemically etched neutron detectors

    International Nuclear Information System (INIS)

    Pitt, E.; Scharmann, A.; Werner, B.

    1988-01-01

    Electrochemical etching has been established as a common method for visualisation of nuclear tracks in solid state nuclear track detectors. Usually the Mason equation, which describes the amplification of the electrical field strength at the track tip, is used to explain the treeing effect of electrochemical etching. The yield of neutron-induced tracks from electrochemically etched CR-39 track detectors was investigated with respect to the electrical parameters. A linear dependence on the response from the macroscopic field strength was measured which could not be explained by the Mason equation. It was found that the reality of a recoil proton track in the detector does not fit the boundary conditions which are necessary when the Mason equation is used. An alternative model was introduced to describe the track and detector geometry in the case of a neutron track detector. The field strength at the track tip was estimated with this model and compared with the experimental data, yielding good agreement. (author)

  6. Track etch and thermo luminescent detectors response to high energy charged particles

    Czech Academy of Sciences Publication Activity Database

    Spurný, František; Jadrníčková, Iva

    2008-01-01

    Roč. 43, Supp. 1 (2008), S169-S173 ISSN 1350-4487. [International Conference on Solids /23./. Beijing, 11.09.2006-15.09.2006] R&D Projects: GA ČR GA202/04/0795 Grant - others:Evropské společenství(XE) ILSRA - 2004 - 248 Institutional research plan: CEZ:AV0Z10480505 Keywords : track etch detector * thermoluminescent detectors * LET spectrometry Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.267, year: 2008

  7. Pinning of 1800 Bloch walls at etched nuclear tracks in LPE-grown iron garnet films

    International Nuclear Information System (INIS)

    Krumme, J.; Bartels, I.; Strocka, B.; Witter, K.; Schmelzer, C.; Spohr, R.

    1977-01-01

    For increasing the magnetic-wall coercivity H/sup w//sub c/ in liquid-phase epitaxial (LPE) ferrimagnetic garnet films of composition (Gd,Bi) 3 (Fe,Al,Ga) 5 O 12 , magnetic-wall ''traps'' are formed via bombardment by xenon ions with 180-MeV/ion energy and doses between 10 6 and 10 8 cm -2 . For efficient wall pinning, the width of the nuclear damage tracks associated with the ion trajectories in the film have been enlarged to about the wall width by using a selective (chemical) etchant that makes use of the drastically increased etching rate in the damaged track volume. Therefore, channels of cylindrical or prismatic cross section are created having a width of a few 10 2 to about 10 3 A and a length of more than 10 μm at the given etching conditions. The pinning capability of such channels can be further enhanced in films that are grown under planar compressive or tensile misfit strain. Then, strain relaxation occurs in the vicinity of these channels which results in steep gradients of the magnetic-wall energy via magnetostriction. These strain halos extend sufficiently beyond the channels so that efficient wall pinning is observed, even if the channel cross section is small compared with the wall width. Thermomagnetic compensation-point writing in LPE garnet film, that were treated accordingly, yield a pattern of stable magnetic domains of down to 8 μm in diameter in 3-μm-thick layers. The effect of etched nuclear tracks on the magnetic-wall coercivity can be interpreted satisfactorily with present models on H/sup w//sub c/

  8. Estimation of Water Diffusion Coefficient into Polycarbonate at Different Temperatures Using Numerical Simulation

    DEFF Research Database (Denmark)

    Shojaee Nasirabadi, Parizad; Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    ) is widely used in the electronics industry. Thus, in this work the water diffusion coefficient into PC is investigated. Furthermore, numerical methods used for estimation of the diffusion coefficient and their assumptions are discussed. 1D and 3D numerical solutions are compared and based on this, itis......Nowadays, many electronic systems are exposed to harsh conditions of relative humidity and temperature. Masstransport properties of electronic packaging materials are needed in order to investigate the influence of moisture andtemperature on reliability of electronic devices. Polycarbonate (PC...... shown how the estimated value can be different depending on the choice of dimensionality in the model....

  9. Highly Conductive Multifunctional Graphene Polycarbonate Nanocomposites

    Science.gov (United States)

    Yoonessi, Mitra; Gaier, James R.

    2010-01-01

    Graphene nanosheet bisphenol A polycarbonate nanocomposites (0.027 2.2 vol %) prepared by both emulsion mixing and solution blending methods, followed by compression molding at 287 C, exhibited dc electrical percolation threshold of approx.0.14 and approx.0.38 vol %, respectively. The conductivities of 2.2 vol % graphene nanocomposites were 0.512 and 0.226 S/cm for emulsion and solution mixing. The 1.1 and 2.2 vol % graphene nanocomposites exhibited frequency-independent behavior. Inherent conductivity, extremely high aspect ratio, and nanostructure directed assembly of the graphene using PC nanospheres are the main factors for excellent electrical properties of the nanocomposites. Dynamic tensile moduli of nanocomposites increased with increasing graphene in the nanocomposite. The glass transition temperatures were decreased with increasing graphene for the emulsion series. High-resolution electron microscopy (HR-TEM) and small-angle neutron scattering (SANS) showed isolated graphene with no connectivity path for insulating nanocomposites and connected nanoparticles for the conductive nanocomposites. A stacked disk model was used to obtain the average particle radius, average number of graphene layers per stack, and stack spacing by simulation of the experimental SANS data. Morphology studies indicated the presence of well-dispersed graphene and small graphene stacking with infusion of polycarbonate within the stacks.

  10. Ammonia modification for flotation separation of polycarbonate and polystyrene waste plastics.

    Science.gov (United States)

    Wang, Chong-Qing; Wang, Hui; Gu, Guo-Hua; Lin, Qing-Quan; Zhang, Ling-Ling; Huang, Luo-Luo; Zhao, Jun-Yao

    2016-05-01

    A promising method, ammonia modification, was developed for flotation separation of polycarbonate (PC) and polystyrene (PS) waste plastics. Ammonia modification has little effect on flotation behavior of PS, while it changes significantly that of PC. The PC recovery in the floated product drops from 100% to 3.17% when modification time is 13min and then rises to 100% after longer modification. The mechanism of ammonia modification was studied by contact angle, and Fourier transform infrared (FT-IR) and X-ray photoelectron spectroscopy (XPS) measurements. Contact angle of PC indicates the decline of PC recovery in the floated product is ascribed to an increase in surface wettability. FT-IR and XPS spectra suggest that ammonia modification causes chemical reactions occurred on PC surface. Flotation behavior of ammonia-modified PC and PS was investigated with respect to flotation time, frother concentration and particle sizes. Flotation separation of PC and PS waste plastics was conducted based on the flotation behavior of single plastic. PC and PS mixtures with different particle sizes are separated efficiently, implying that the technology possesses superior applicability to particle sizes of plastics. The purity of PS and PC is up to 99.53% and 98.21%, respectively, and the recovery of PS and PC is larger than 92.06%. A reliable, cheap and effective process is proposed for separation of PC and PS waste plastics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Depth sensitivity of Lexan polycarbonate detector

    CERN Document Server

    Awad, E M

    1999-01-01

    The dependence of the registration sensitivity of Lexan polycarbonate with depth inside the detector was studied. Samples of Lexan from General Electric were irradiated to two long range ions. These were Ni and Au ions with a projectile energy of 0.3 and 1 GeV/n. Two independent techniques, the track-diameter technique (TDT) and the track profile technique (TPT), were used. The registration sensitivity was measured at depths of 7, 10, 15, 18, 20, 28, 35 and 40 mu m inside the detector. The results of the two techniques show that the detector sensitivity decreases gradually with the depth inside the detector. It reaches 20 % less compared to sensitivity at the surface after 40 mu m have been removed.

  12. Optical and nanomechanical study of anti-scratch layers on polycarbonate lenses

    Science.gov (United States)

    Charitidis, C.; Laskarakis, A.; Kassavetis, S.; Gravalidis, C.; Logothetidis, S.

    2004-07-01

    In recent years, as the optical-electronic industry developed, polymeric materials were gradually increasing in importance. Polycarbonate (PC) is a good candidate for eyewear applications due to its low weight and transparency. In the case of PC lenses, the deposition of anti-scratch (AS) coatings on the polymer surface is essential for the improvement of the mechanical behavior of the lens. In this work, we present a detailed investigation of the optical and nanomechanical properties of a PC based optical lens and coated by an AS coating as a protective overcoat. The study of the effect of the AS coating on the optical response of the PC lens has been performed by the use of Spectroscopic Ellipsometry (SE) in the IR spectral region, where the characteristic features corresponding to the different bonding configuration of the PC lens and the AS coating were studied. Also, the nanomechanical study of the PC lens, before and after the deposition of the AS coating, performed by nanoindentation measurements revealed the significant enhancement of the mechanical response of the AS/PC lens. More specifically, the AS/PC lens is characterized by enhanced values of hardness and elastic modulus. Finally, the use of AS coating has found to lead to a better scratch resistance and to the reduction of the coefficient of friction (μ) of the PC lens.

  13. Observation of nuclear track in organic material by atomic force microscopy in real time during etching

    CERN Document Server

    Palmino, F; Labrune, J C

    1999-01-01

    The developments of Atomic Force Microscopy (AFM) allow to investigated solid surfaces with a nanometer scale. These techniques are useful methods allowing direct observation of surface morphologies. Particularly in the nuclear track fields, they offer a new tool to give many new informations on track formation. In this paper we present the preliminary results of a new use of this technique to characterize continuously the formation of the revealed track in a cellulose nitrate detector (LR115) after an alpha particle irradiation. For that, a specific cell has been used to observe, by nano-observations, the evolution of track shapes simultaneously with chemical treatment. Thus, the track shape evolution has been studied; visualizing the evolution of the tracks in real time, in situ during the chemical etching process.

  14. Nuclear tracks in CR-39 produced by carbon, oxygen, aluminium and titanium ions.

    Science.gov (United States)

    Rickards, J; Romo, V; Golzarri, J I; Espinosa, G

    2002-01-01

    This work describes the response of CR-39 (allyl diglycol polycarbonate) to different ions (C, O, Al and Ti) produced by the Instituto de Fisica 3 MV 9SDH-2 Pelletron accelerator and backscattered from a thin Au film on a C support. The ion energies were chosen in series such that the ranges of the different ions in the detector were 2, 3, 4, 5, 6, 7 and 8 microm respectively for each series. Once exposed, the detectors were etched with a solution of 6.25 M KOH at 60 degrees C, and the reading was carried out using a digital image analysis system. An analysis of the measured track diameters of all the types of ions indicates that, for a given range, track kinetics are independent of type of ion, energy and stopping power.

  15. Etch induction time in cellulose nitrate: a new particle identification parameter

    International Nuclear Information System (INIS)

    Ruddy, F.H.; Knowles, H.B.; Luckstead, S.C.; Tripard, G.E.

    1977-01-01

    By the use of a 'continuous etch' method, it has been ascertained that particle tracks do not appear in cellulose nitrate track detectors until a certain finite time after etch has been started: this etch induction time may provide a unique signal for distinguishing ions of different atomic number, Z, and possibly also resolving the mass, M, of such ions. Empirical relations between etch induction time and various experimental quantities are described, as is a simple theory of the cause of etch induction time, which can be related to experimental evidence on hand. There is reason to believe that etch induction time appears in other types of plastic track detectors and may indeed be a general phenomenon in all track detectors. (Auth.)

  16. Probing the role of poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) -coated multiwalled carbon nanotubes in the thermal and mechanical properties of polycarbonate nanocomposites

    KAUST Repository

    Zhou, Jian

    2014-03-05

    The role played by multiwalled carbon nanotubes (MWCNTs) coated with poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) in the thermal and mechanical properties of polycarbonate (PC) nanocomposites was analyzed. We used differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA) to demonstrate that the glass transition temperature of polycarbonate nanocomposites decreased whereas the storage modulus of the samples increased by including PEDOT/PSS-coated MWCNTs. These results indicated that PEDOT/PSS acts as an antiplasticizer. We attributed the enhancement of the storage modulus to the strong hydrogen bonding between PSS and the PC matrix and the reduction of the free volume in the PC matrix due to the shrinkage of PEDOT/PSS upon heating. We also investigated changes in the thermal conductivity and thermal degradation behavior of the nanocomposites. The results indicated that PEDOT/PSS did not play a significant role in improving the thermal conductivity and thermal stability of PC nanocomposites. The relative improvements in the conductivity and thermal stability of the samples that contained PEDOT/PSS were attributed to the better dispersion of the MWCNTs in the PC matrix. © 2014 American Chemical Society.

  17. Effect of ZnO nano in the blend PET / PC ( 80/20) subjected to UV radiation

    International Nuclear Information System (INIS)

    Pires, Homero M.; Mendes, Luis C.; Albitres, Gerson A.V.; Cestari, Sibele P.; Mattos, Gabriela C.

    2015-01-01

    The aim of this research was to reuse recycled poly(ethylene terephthalate) (PET) in blend with polycarbonate (PC) in order to avoid UV degradation in outdoor application. Nanocomposite based on blend of recycled (PET) and polycarbonate (PC) in the ratio of 80/20 with nano zinc oxide (ZnO) at different concentrations was prepared. The blend was subjected to ultraviolet (UV) radiation for accelerated aging chamber, we evaluated the effect of the presence nZnO filler as a barrier to UV rays. Dynamic-mechanical analysis (DMA) and nuclear magnetic resonance in the solid state (NMR). It is the degradation retardant effect at concentrations starting from 3% nZnO. (author)

  18. Nanocomposites of recycled polycarbonate and nano-zinc oxide (rPC/nZnO): effect of gamma radiation and nano oxide content on the thermal properties; Nanocompositos de policarbonato reciclado e nanooxido de zinco (rPC/nZnO): efeito da radiacao-gama e do teor de nanooxido nas propriedades termicas

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, A.L.F.; Mendes, L.C.; Cestari, S.P., E-mail: anafcarvalho@ima.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Instituto de Macromoleculas Eloisa Mano; Souza, M.C.L. [Universidade Estadual da Zona Oeste (UEZO), RJ (Brazil)

    2014-07-01

    In order to promote the barrier action to the ultraviolet radiation and increase of mechanical characteristics, nanocomposites of recycled polycarbonate (rPC) and nano-zinc oxide (nZnO) containing 1, 2 and 3 % (wt/wt) of nano oxide were prepared. Since for obtaining nanocomposites and irradiating polymers are promising tools and attractive for improving the material performance, the effects of nano-zinc oxide and gamma radiation, at doses ranged from 10 to 50 kGy, were evaluated in terms of thermal characteristics of the rPC. The rPC/nZnO nanocomposites were characterized by thermogravimetric analysis (TGA) and differential explanatory calorimetry (DSC). There was a progressive decrease of the T{sub g} as function of gamma dosage and nano-zinc oxide content. Initially, the Tonset and Tmax decayed as function of gamma dosage but a recovery was observed. The amount of nano-zinc oxide induced a decreasing of T{sub onset} and T{sub max}. (author)

  19. Solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Medeiros, J.A.; Carvalho, M.L.C.P. de

    1992-12-01

    Solid state nuclear track detectors (SSNTD) are dielectric materials, crystalline or vitreous, which registers tracks of charged nuclear particles, like alpha particles or fission fragments. Chemical etching of the detectors origin tracks that are visible at the optical microscope: track etching rate is higher along the latent track, where damage due to the charged particle increase the chemical potential, and etching rate giving rise to holes, the etched tracks. Fundamental principles are presented as well as some ideas of main applications. (author)

  20. The Weathering Study of PC/ASA Alloy For Automotive Exterior Applications

    Directory of Open Access Journals (Sweden)

    Sinan Öztürk

    2017-10-01

    Full Text Available Polycarbonates (PC are used in automotive industry due to high physical and mechanical properties like high impact resistance and ductility. Polycarbonates are blended with ABS (Acrylonitrile-Butadiene-Styrene and ASA (Acrylonitrile-Styrene-Acrylate terpolymers for interior and exterior applications of automotive components to achieve good physical and mechanical properties. Other reason for choosing such alloys for interior applications is the IZOD impact resistance requirement higher than 40kJ/m2. Recently, grades of PC/ASA with UV stabilized are developed for non-painted exterior applications. The aim of our study is to investigate whether new developed PC/ASA could be chosen for exterior applications of automotive industry. In this study, the samples are prepared from injection molding and the weathering performance of PC/ASA was tested by a weather-o-meter for 1500h at a total of 1890 kJ/m2 at 340nm with a cut-off filter at λ<290nm. The results are evaluated by FT-IR, DSC, TGA and SEM. It has been observed that UV degradation of PC/ASA leads to several major changes in its IR spectrum like broad bands occurred in the hydroxyl region around 3300 cm-1, and carbonyl stretching region increased around 1728 cm-1. The main degradations were based on photo-oxidation and photo-Fries rearrangement of PC. In our study, the photo-oxidation was followed by the color shift to yellowing of the polymer.

  1. Effect of neutron irradiation on etching, optical and structural properties of microscopic glass slide used as a solid state nuclear track detector

    International Nuclear Information System (INIS)

    Singh, Surinder; Kaur Sandhu, Amanpreet; Prasher, Sangeeta; Prakash Pandey, Om

    2007-01-01

    Microscopic glass slides are soda-lime glasses which are readily available and are easy to manufacture with low production cost. The application of these glasses as nuclear track detector will help us to make use of these glasses as solid-state nuclear track detector. The present paper describes the variation in the etching, optical and structural properties of the soda-lime microscopic glass slides due to neutron irradiation of different fluences. The color transformation and an increase in the optical absorption with neutron irradiation are observed. Both the bulk and track etch rates are found to increase with neutron fluence, thus showing a similar dependence on neutron fluence, but the sensitivity remains almost constant

  2. Mechanism of track formation by charged particles in inorganic and organic solid-state track detectors

    International Nuclear Information System (INIS)

    Doerschel, B.; Pretzsch, G.; Streubel, G.

    1979-01-01

    Knowledge of the individual phases of track formation mechanism is necessary in some applications of solid-state track detectors. The generation of latent tracks is described by energy transfer processes of the charged particles along their paths using several different models. Etchability of the latent tracks is discussed on the basis of some distinct criteria taking into account different fractions of energy release by the primary and secondary particles during track generation. If these etchability criteria for latent tracks are fulfilled, visual particle tracks can be produced by a chemical etching process. Etch pit formation depends on the etching conditions. The geometrical parameters of the etching pits are given on the basis of known etching rates. Evaluation of individual particle tracks or determination of track density yields results depending on both the properties of the particles and the etching conditions. Determination of particle energy and particle fluence is discussed as an example. (author)

  3. Estimation of water diffusion coefficient into polycarbonate at different temperatures using numerical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Nasirabadi, P. Shojaee; Jabbari, M.; Hattel, J. H. [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark)

    2016-06-08

    Nowadays, many electronic systems are exposed to harsh conditions of relative humidity and temperature. Mass transport properties of electronic packaging materials are needed in order to investigate the influence of moisture and temperature on reliability of electronic devices. Polycarbonate (PC) is widely used in the electronics industry. Thus, in this work the water diffusion coefficient into PC is investigated. Furthermore, numerical methods used for estimation of the diffusion coefficient and their assumptions are discussed. 1D and 3D numerical solutions are compared and based on this, it is shown how the estimated value can be different depending on the choice of dimensionality in the model.

  4. Visualization of boron in molybdenum by α-rays track etching method and tritium autoradiography

    International Nuclear Information System (INIS)

    Saito, Hideo; Morita, Fumio

    2003-01-01

    Molybdenum alloys addicted with < 0.02 ppm B to 160 ppm B were analyzed by α-rays track etching (ATE) method irradiated by thermal neutron for 12 hours using atomic reactor of Rikkyo University and Japan atomic reactor of JRR-4. It was found that boron was segregated along grain boundaries and in the matrix. We analyzed boron distribution in the vicinity of the triple junctions at grain boundaries and in the matrix by the statistical frequency of α-rays tracks. Also we studied tritium autoradiography by cathodic charging method. Visualization of boron distribution was confirmed along the grain boundary which seemed to be effective trapping sites of hydrogen. (author)

  5. Radiation effects in the polycarbonate of bisphenol-A. Thermoluminescence electron spin resonance and charged particle track studies

    International Nuclear Information System (INIS)

    Edmonds, E.A.

    1978-09-01

    A detailed investigation is presented of the thermoluminescence observable above room temperature from the polycarbonate of bisphenol-A after its exposure to different radiations. A correlation study is described by which features of the complex thermoluminescence glow curve from a commercial grade of the polycarbonate of bisphenol-A are related to the etchability of charged particle damage trails and the radiogenic ESR signal. A model is presented whereby the etchability of charged particle damage trails is associated with chain scission caused by the high local dose of radiation in the vicinity of the trajectories of charged particles. Methods by which activation constants controlling the thermoluminescence glow curve can be evaluated are discussed and results are presented. It is concluded that glow peaks associated with the ESR signal or enhanced etchability are related to small-scale motions in the molecular matrix of the polycarbonate of bisphenol-A. These motions are thermally activated in accord with the simple Boltzmann relation usually incorporated into theories of thermoluminescence. Another component glow peak of the thermoluminescence glow curve is shown to be associated with the glass-rubber transition in the polycarbonate of bisphenol-A. Different features of the thermoluminescence glow curve can be related to relaxations of the polymer matrix and decomposition of the matrix. It is confirmed that the dominant bulk effect of radiation in the polycarbonate of bisphenol-A exposed to large doses of radiation is chain scission. (author)

  6. Study on active faults in the Izu Peninsula using α track etch method

    International Nuclear Information System (INIS)

    Katoh, K.; Ikeda, K.; Takahashi, M.; Nagata, S.; Yanagihara, C.

    1981-01-01

    The α track etch method, which is one of the geochemical survey methods for the mapping and detection of active faults and the evaluation of their activities, has been applied to ten sites for the purpose of the earthquake prediction research program. The method conventionally measures relative radon concentration in the soil gas by counting the number of tracks per cm 2 .day on a small piece of plastic film (cellulose nitrate) which is sensitive to α-ray radiation. As the result of the track measurement on many survey lines crossing ten active faults including earthquake faults in the Izu Peninsula, the following was clarified: 1. The peak of track number appears mostly on fault lines but sometimes shifts from it. The line connecting peaks on the several survey lines corresponds to the strike of fault. 2. Relative position between the peak and the fault line on the surface suggests the type of fault, normal or reverse. 3. The track number observed on thin Quaternary strata is generally larger than that on thick Quaternary strata at an active fault concerned. This fact shows that the rising time of radon gas is controlled by the thickness of covering strata. (author)

  7. Polycarbonate Durolon degradation submitted to gamma radiation

    International Nuclear Information System (INIS)

    Miranda, A.; Sciani, V.

    1993-01-01

    The Polycarbonate (PC) Durolon, produced by Policarbonatos do Brasil S.A. with molecular weight 27,000 g/mol was irradiated with 60-Co gamma ray source at IPEN-CNEN/SP with doses range between 0.2 to 1,000 kGy in air at 25 C. The results showed that up to 20 kGy no changes in mechanical properties were observed. Above this value, a drop of the elongation to break was observed, reaching 50% drop of its value by 500 kGy. On the other hand, optical tests showed that about 5 kGy some transmittance variations occurred, reaching 3% of its value for a dose of 300 kGy. (author)

  8. Independent Control of Adhesive and Bulk Properties of Hybrid Silica Coatings on Polycarbonate

    OpenAIRE

    Lionti , Krystelle; Cui , Linying; Volksen , Willi; Dauskardt , Reinhold; Dubois , Geraud; Toury , Bérangère

    2013-01-01

    International audience; Transparent polymers are widely used in many 9 applications ranging from automotive windows to micro-10 electronics packaging. However, their intrinsic characteristics, 11 in particular their mechanical properties, are significantly 12 degraded with exposure to different weather conditions. For 13 instance, under humid environment or UV-irradiation, 14 polycarbonate (PC) undergoes depolymerization, leading to 15 the release of Bisphenol A, a molecule presumed to be a 1...

  9. Anti-biofilm efficacy of 100 MeV gold ion irradiated polycarbonate against Salmonella typhi

    Science.gov (United States)

    Joshi, R. P.; Hareesh, K.; Bankar, A.; Sanjeev, G.; Asokan, K.; Kanjilal, D.; Dahiwale, S. S.; Bhoraskar, V. N.; Dhole, S. D.

    2017-12-01

    Polycarbonate (PC) films were irradiated by 100 MeV gold (Au7+) ions and characterized to study changes in its optical, chemical, surface morphology and thermal properties. UV-Visible spectroscopic results revealed the decrease in the optical band gap of PC after ion irradiation due to chain scission mainly at the carbonyl group which is corroborated by Fourier Transform Infrared spectroscopic results. X-ray diffractogram study showed decrease in crystallinity of PC film after irradiation. Scanning electron microscopic results showed the micropores formation in PC which results in surface roughening. Differential scanning calorimetric results revealed decrease in glass transition temperature indicating the decrease in molecular weight of PC corroborated by rheometric studies. PC films irradiated by 100 MeV Au7+ ions showed increased anti-biofilm activity against the human pathogen, Salmonella typhi (S. typhi). Morphology of S. typhi was changed due to stress of Au7+ irradiated PC. Cells length was increased with increasing fluences. The average cell length, cell volume and surface area was increased significantly (PBiofilm formation was inhibited ≈ 20% at lower fluence and 96% at higher fluence, which observed to be enhanced anti-biofilm activity in Au7+ irradiated PC.

  10. Photostable nonlinear optical polycarbonates

    NARCIS (Netherlands)

    Faccini, M.; Balakrishnan, M.; Diemeer, Mart; Torosantucci, Riccardo; Driessen, A.; Reinhoudt, David; Verboom, Willem

    2008-01-01

    Highly thermal and photostable nonlinear optical polymers were obtained by covalently incorporating the tricyanovinylidenediphenylaminobenzene (TCVDPA) chromophore to a polycarbonate backbone. NLO polycarbonates with different chromophore attachment modes and flexibilities were synthesized. In spite

  11. Separation of polycarbonate and acrylonitrile-butadiene-styrene waste plastics by froth flotation combined with ammonia pretreatment.

    Science.gov (United States)

    Wang, Chong-Qing; Wang, Hui; Liu, Qun; Fu, Jian-Gang; Liu, You-Nian

    2014-12-01

    The objective of this research is flotation separation of polycarbonate (PC) and acrylonitrile-butadiene-styrene (ABS) waste plastics combined with ammonia pretreatment. The PC and ABS plastics show similar hydrophobicity, and ammonia treatment changes selectively floatability of PC plastic while ABS is insensitive to ammonia treatment. The contact angle measurement indicates the dropping of flotation recovery of PC is ascribed to a decline of contact angle. X-ray photoelectron spectroscopy demonstrates reactions occur on PC surface, which makes PC surface more hydrophilic. Separation of PC and ABS waste plastics was conducted based on the flotation behavior of single plastic. At different temperatures, PC and ABS mixtures were separated efficiently through froth flotation with ammonia pretreatment for different time (13 min at 23 °C, 18 min at 18 °C and 30 min at 23 °C). For both PC and ABS, the purity and recovery is more than 95.31% and 95.35%, respectively; the purity of PC and ABS is up to 99.72% and 99.23%, respectively. PC and ABS mixtures with different particle sizes were separated effectively, implying that ammonia treatment possesses superior applicability. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Investigation of the response of Lexan polycarbonate to relativistic ultra heavy nuclear particles

    CERN Document Server

    Keane, A J; O'Sullivan, D

    1999-01-01

    Recent investigations of the track response of Lexan to relativistic ultra heavy nuclei are reported. The inherent charge resolution of Lexan for relativistic ultra heavy nuclei under normal exposure conditions at accelerators has been investigated. The registration temperature effect was measured using gold (Z=79) at energies 2, 4 and 11 GeV/u covering a wide range of temperatures from -78 deg. C to +22 deg. C. In addition, the sensitivity of the track etch rate and the bulk etch rate to etch product concentration was re-examined.

  13. Investigation of the response of Lexan polycarbonate to relativistic ultra heavy nuclear particles

    International Nuclear Information System (INIS)

    Keane, A.J.; Thompson, A.; O'Sullivan, D.

    1999-01-01

    Recent investigations of the track response of Lexan to relativistic ultra heavy nuclei are reported. The inherent charge resolution of Lexan for relativistic ultra heavy nuclei under normal exposure conditions at accelerators has been investigated. The registration temperature effect was measured using gold (Z=79) at energies 2, 4 and 11 GeV/u covering a wide range of temperatures from -78 deg. C to +22 deg. C. In addition, the sensitivity of the track etch rate and the bulk etch rate to etch product concentration was re-examined

  14. Processing of plastic track detectors

    International Nuclear Information System (INIS)

    Somogyi, G.

    1977-01-01

    A survey of some actual problems of the track processing methods available at this time for plastics is presented. In the case of the conventional chemical track-etching technique, mainly the etching situations related to detector geometry, and the relationship between registration sensitivity and the etching parameters are considered. Special attention is paid to the behaviour of track-revealing by means of electrochemical etching. Finally, some properties of a promising new track processing method based on graft polymerization are discussed. (author)

  15. Processing of plastic track detectors

    International Nuclear Information System (INIS)

    Somogyi, G.

    1976-01-01

    A survey of some actual problems of the track processing methods available at this time for plastics is presented. In the case of the conventional chemical track etching technique mainly the etching situations related to detector geometry and the relationship of registration sensitivity and the etching parameters are considered. A special attention is paid to the behaviour of track revealing by means of electrochemical etching. Finally, some properties of a promising new track processing method based on graft polymerization is discussed. (orig.) [de

  16. Effect of Pore Geometry on Resistive-Pulse Sensing of DNA Using Track-Etched PET Nanopore Membrane

    International Nuclear Information System (INIS)

    Kaya, Dila; Dinler, Ali; San, Nevim; Kececi, Kaan

    2016-01-01

    We have investigated the effect of nanopore geometry on translocation properties of poly(ethylene terephthalate) (PET) membranes. In order to vary the cone angles of the conically shaped nanopores, which were obtained by track-etch method, we have added different volume fractions of methanol to the alkali etching solution. We have confirmed through the characterization of PET membranes that methanol has a promoting effect on cone angle. Additionally, we have reported the positive influence of a higher cone angle for resistive pulse sensing of 50-bp DNA. We have also shown the change in electric field as a function of cone angle by using finite element simulations and confirmed a higher electric field with increasing cone angle.

  17. Scanning transmission ion microscopy of polycarbonate nanocapillaries

    International Nuclear Information System (INIS)

    Gal, G.A.B.; Rajta, I.; Szilasi, S.Z.; Juhasz, Z.; Biri, S.; Csik, A.; Sulik, B.; Cserhati, Cs.

    2011-01-01

    Complete text of publication follows. Nanochanneled materials are of a great interest due to their peculiar properties and high potential impact for the fabrication of nanostructures and nanodevices. Polycarbonate membranes are produced by heavy ion irradiation followed by chemical etching of the ion tracks. The irradiation parameters determine the porosity (areal density of the capillaries) and angular spread, while the channel diameters and shapes depend on the chemical process parameters. Such polycarbonate (and other materials) membranes are commercially available from a few manufacturers. The primary use of the filters involves packaging and filtering applications. Moreover, they are used for collecting atmospheric aerosols for environmental research. The nanocapillaries formed in membranes are particularly suitable for ion and electron guiding studies of a recently discovered, but not yet completely understood capillary guiding phenomenon. This interesting guiding effect is very promising for patterning by parallel writing with ions and/or electrons through masks. In order to get a better understanding of this phenomenon, we need a better characterization of the capillaries themselves. This study is addressing the angular distribution of the nanochannels in the polycarbonate filters by using a nuclear microprobe facility and the method of scanning transmission ion microscopy (STIM). The STIM experiments in this work have been performed at ATOMKI. The proton energy was 2 MeV, the beam intensity was about 1000 protons s -1 , the beam spot size was about 1 x 1 μm, the scan size was 100 x 100 μm and the beam divergence was smaller than 0.07 deg. A scanning electron microscope (SEM, Hitachi S4300 CFE) was used to measure the capillary diameters and the membrane porosity. The sample thickness was determined by a profilometer (AMBIOS XP-I). We have investigated two different pieces of Millipore Isopore TM samples. A typical SEM image showed several overlapping

  18. Hydrophilicity and morphological investigation of polycarbonate irradiated by ArF excimer laser

    Energy Technology Data Exchange (ETDEWEB)

    Jaleh, B. [Bu-Ali-Sina University, Physics Department, Postal Code 65174, Hamedan (Iran, Islamic Republic of)], E-mail: jaleh@basu.ac.ir; Parvin, P. [Amir Kabir University of Technology, Physics Department, P.O. Box: 15875-4413, Tehran (Iran, Islamic Republic of); Laser Research Center, AEOI, P.O. Box: 11365-8486, Tehran (Iran, Islamic Republic of); Sheikh, N. [Nuclear Science and Technology Research Institute, Radiation Applications Research School, Tehran (Iran, Islamic Republic of); Zamanipour, Z. [Laser Research Center, AEOI, P.O. Box: 11365-8486, Tehran (Iran, Islamic Republic of); Sajad, B. [Azzahra University, Physics Department, Tehran (Iran, Islamic Republic of)

    2007-12-15

    Lasers are used to modify polymeric materials. In this work, a number of polycarbonate (PC) pieces were exposed by ArF excimer laser, 193 nm, at various UV doses from 10 to 100 J/cm{sup 2} with 50-500 mJ/pulse at 10 Hz pulse repetition rate. Morphology of PC has been investigated by scanning electron microscope (SEM) at three regimes pre-ablation, slow and fast ablation. SEM identifies that the conical defects are created on the polymer surface to grow opposite to the direction of laser irradiation. It increases the superficial absorptivity of the material dependent on the ArF laser induced conical microstructure geometry. The contact angle measurement was performed here, in order to determine the hydrophilicity of the irradiated polymer at various coherent doses. It is shown that the contact angle of PC samples which are exposed to the ArF laser significantly alters with UV dose below 7 J/cm{sup 2}.

  19. Electrochemical aptasensor for detecting Der p2 allergen using polycarbonate-based double-generation gold nanoparticle chip

    Directory of Open Access Journals (Sweden)

    Ming-Che Shen

    2017-04-01

    Full Text Available In this study, a novel aptamer-based impedimetric biosensor for detecting the group 2 allergen of Dermatophagoides pteronyssinus (Der p2 was developed. First, an anodic aluminum oxide (AAO membrane was prepared. A modified AAO barrier-layer surface with an array of nanohemispheres of 400 nm in diameter was used as a template for the nanoelectroforming of a nickel mold. After electroforming, the AAO template was etched and a nickel nanomold with a concave nanostructure array was produced. The formed nanostructured nickel nanomold was then used in the replica molding of a nanostructured polycarbonate (PC substrate via hot embossing. Finally, a gold thin film was sputtered onto the PC substrate to form a double-generation gold nanoparticle electrode (array of nanohemispheres with smaller nanoparticles orderly distributed on each nanohemisphere. After immobilizing specifically designed aptamers on the fabricated electrode, electrochemical impedance spectroscopy was used to determine the concentration of Der p2. The sensitivity of the proposed scheme for the detection of the dust mite antigen Der p2 was 2.088 Ω / (ng/mL × cm2 with a dynamic detection range of 27.5–400 ng/mL and detection limit of 16.47 ng/mL.The aptamer-based impedimetric biosensor proposed in this study possesses many advantages such as high sensitivity, low cost, and high consistency over currently used sensors. The proposed sensor was found to be useful for the rapid detection of rare molecules present in an analyte. Keywords: Aptamers, Der p2 dust mite allergen detection, Nanostructured biosensors, Electrochemical impedance spectroscopy

  20. A study of AFM-based scratch process on polycarbonate surface and grating application

    International Nuclear Information System (INIS)

    Choi, Chul Hyun; Lee, Dong Jin; Sung, Jun-Ho; Lee, Min Woo; Lee, Seung-Gol; Park, Se-Geun; Lee, El-Hang; O, Beom-Hoan

    2010-01-01

    We report on the possibility of applying atomic force microscope (AFM) lithography to draw micro/nano-structures on the surface of a polycarbonate (PC) substrate. We also fabricated a grating structure on the PC surface using the scratch method. An AFM silicon tip coated with a diamond layer was utilized as a cutting tool to scratch the surface of the sample. In order to obtain pattern depth deeper than the control method of interaction force, we used a scanner movement method which the sample scanner moves along the Z-axis. A grating of 100 μm x 150 μm was fabricated by the step and repeat method wherein the sample stage is moved in the direction of the XY-axis. The period and the depth of the grating are 500 and 50 nm, respectively. Light of 632.8 nm wavelength was diffracted on the surface of the PC substrate.

  1. The combined effect of gamma radiation and stress cracking in polycarbonate

    International Nuclear Information System (INIS)

    Melo, Raphaela N. de; Rabello, Marcelo S.

    2009-01-01

    In this work the combined effect of gamma irradiation and stress cracking was studied in polycarbonate (PC). Tensile test bars were produced by injection moulding and then exposed to different doses of gamma radiation. After that they were submitted to the contact with isopropanol, the stress cracking agent used in this work. The specimens were tested for mechanical properties, viscosity molecular weight and fractography. The results indicated that the previous radiation intensified the stress cracking effects, as evidenced by the reduction in tensile properties and surface damage caused to the samples. (author)

  2. The effects of pre-etching time on the characteristic responses of electrochemically etched CR-39 neutron dosimeters

    International Nuclear Information System (INIS)

    Sohrabi, M.; Khoshnoodi, M.

    1986-01-01

    The effects of pre-etching time (PET) or duration of etching of fast-neutron-induced-recoil tracks in CR-39 in 6N KOH at 60 0 C on electrochemical etching neutron characteristic responses; i.e. sensitivity and mean recoil track diameter (MRTD) versus KOH normality up to 18N are investigated in this paper. Six sets of responses for PETs of 0, 1, 2, 3, 4, and 5 hours were obtained by using our new multi-chamber ECE (MCECE) system which reduced total operation time to about 6% of the time usually required when single-chamber ECE systems are used. The sensitivity response for zero PET showed a broad plateau and a high sensitivity low-LET peak around 16N. By increasing PET, another peak was also developed around 5N leading to 'double-humped' responses with two maximums around 5N and 16N, and a minimum around 11N. On the other hand, the MRTD responses for all PETs studied showed the same general trend with maximums around 11N. In this paper, shape of tracks under different conditions are also investigated, new optimum conditions such as KOH concentrations of 5, 11, and 15N at 25 0 C, with or without pre-etching, are recommended for tracks of lower-LET recoils including possibly protons, and alpha particle tracks over a broad energy range, and the efficiency of the MCECE system is also demonstrated. (author)

  3. Dosimetry and microdosimetry using LET spectrometer based on the track-etch detector: radiotherapy Bremsstrahlung beam, onboard aircraft radiation field

    International Nuclear Information System (INIS)

    Jadrnickova, I.; Spurny, F.

    2006-01-01

    The spectrometer of linear energy transfer (Let) based on the chemically etched poly-allyl-diglycol-carbonate (P.A.D.C.) track-etch detector was developed several years ago in our institute. This Let spectrometer enables determining Let of particles approximately from 10 to 700 keV/μm. From the Let spectra, dose characteristics can be calculated. The contribution presents the Let spectra and other dosimetric characteristics obtained onboard a commercial aircraft during more than 6 months long exposure and in the 18 MV radiotherapy Bremsstrahlung beam. (authors)

  4. Phase Behavior, Thermal Stability and Rheological Properties of PPEK/PC Blends

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Phase behavior, thermal stability and rheological properties of the blends of poly(phthalazinone ether ketone) (PPEK)with bisphenol-A polycarbonate (PC) prepared by solution coprecipitation were studied using differential scanning calorimetry (DSC), Frourier-Transform IR spectroscopy (FT-IR), thermogravimetric analysis (TGA) and capillary rheometer. The DSC results indicated that PPEK/PC blends are almost immiscible in full compositions. FT-IR investigation showed that there were no apparent specific interactions between the constituent polymers. The blends keep excellent thermal stability and the addition of PC degrades the thermal stability of blends to some degree. The thermal degradation processes of the blends are much similar to that of PC. The studies on rheological properties of blends show that blending PPEK with PC is beneficial to reducing the melt viscosity and improving the appearance of PPEK.

  5. Track-etched detectors for the dosimetry of the radiation of cosmic origin

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    2004-01-01

    Cosmic rays contribute to the exposure on the Earth's surface as well as in its surroundings. At the surface and/or at aviation altitudes, there are mostly secondary particles created through the cosmic rays interaction in the atmosphere, which contribute to this type of exposure. Onboard a spacecraft, the exposure comes mostly from primary cosmic rays. Track-etched detectors (TED) are able to characterise both these types of exposure. The contribution of neutrons, of cosmic origin, on the Earth's surface was studied at altitudes from few hundreds to 3000 m using TED in a moderator sphere. The results obtained are compared with other data on this type of natural radiation background. The results of studies performed onboard aircraft and/or spacecraft are presented afterwards. We used TED-based neutron dosemeter, as well as a spectrometer of linear energy transfer based on a chemically etched TED. The results of studies performed onboard aircraft, as well as spacecraft, are presented and discussed, including an attempt to estimate a neutron component onboard the spacecraft. It was found that they correlate with the results of other independent investigations. (authors)

  6. Response of LET spectrometer based on track etching at some neutron sources

    International Nuclear Information System (INIS)

    Spurny, Frantisek; Brabcova, Katerina; Jadrnickova, Iva

    2008-01-01

    There is still need to develop upgrade, and test further methods able to characterise the external exposure to neutrons. This contribution presents further results obtained with the goal to enlarge and upgrade the possibility of neutron dosimetry and microdosimetry with a LET spectrometer based on the chemically etched track detectors (TED). As TED we have used several types of polyallyldiglycolcarbonates (PADC). The PADC detectors have been exposed in: high energy neutron beams at iThemba facility, Cape Town, South Africa, and in monoenergetic neutron beams at JRC Geel, Belgium. The studies have been performed in the frame of the ESA supported project DOBIES. (author)

  7. Electrochemical development of particle tracks in CR-39 polymer dosimeter

    International Nuclear Information System (INIS)

    Hadlock, D.E.; Parkhurst, M.A.; Yang, C.S.; Groeger, J.; Johnson, J.R.; Huang, S.J.

    1985-09-01

    Electrochemical etching of CR-39 polymeric track etch neutron detectors results in proton-recoil tracks can be distinguished from background tracks much better than tracks developed solely by chemical etching. A newly designed and constructed electrochemical etching apparatus allows large numbers of dosimeters to be processed simultaneously with consistent results. Many processing systems have been developed for chemical and electrochemical etching of the track etch dosimeters. Three systems specifically show great promise and are being studied extensively

  8. Radiation dosimetry for microbial experiments in the International Space Station using different etched track and luminescent detectors

    Czech Academy of Sciences Publication Activity Database

    Goossens, O.; Vanhavere, F.; Leys, N.; De Boever, P.; O'Sullivan, D.; Zhou, D.; Spurný, František; Yukihara, E.; Gaza, R.; McKeever, S.

    2006-01-01

    Roč. 120, 1- 4 (2006), s. 433-437 ISSN 0144-8420 R&D Projects: GA MŠk 1P05OC032 Institutional research plan: CEZ:AV0Z10480505 Keywords : bacteria l experiments * space flight * etched track detectors * thermoluminescent detectors Subject RIV: DN - Health Impact of the Environment Quality Impact factor: 0.446, year: 2006

  9. Advances on research, development and applications of SSNTDs in radiation protection at AEOI

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1991-01-01

    Iran is one of the countries which started early in 1967 on research into, and the development and application to radiation protection of solid state nuclear track detectors (SSNTDs). Since then extensive efforts have been made at the National Radiation Protection Department (NRPD) in the Atomic Energy Organization of Iran (AEOI) on national development and international cooperation to promote the application of SSNTDs in this field. These include: efficient track registration of alphas, recoils and fission fragments in different SSNTD materials; advances and new findings on chemical and electrochemical etching (ECE); the introduction of new neutron personnel dosimeters such as the 237 Np/10 μm polycarbonate combination (PC) foils coupled with a spark counting technique; ECE of recoils; Neutriran Albedo Neutron Personnel Dosimetry; neutron depth dose measurements in particular at air-tissue and bone-tissue interfaces; neutron contamination measurements in high energy x-ray beams of medical accelerators; development of a nationwide indoor radon monitoring program and spectrometry of radon daughters in PC; the discovery of some new phenomena in ECE; education and training. Some of these are presented and discussed in this paper. (author)

  10. Influence of nitrogen on the tribological properties of a-C:H layers on the polycarbonate substrates

    Directory of Open Access Journals (Sweden)

    Rafal M. Nowak

    2008-12-01

    Full Text Available Polycarbonate (PC possesses many commercial applications. However, PC is still limited to non-abrasive and chemical-free environments due to its low hardness, low scratching resistance and high susceptibility to chemical attacks. To overcome this limitation, PC can be coated by hydrogenated amorphous carbon layers. The a-C:H layers have very attractive properties such as high hardness, infrared transparency, chemical inertness, low friction coefficients, and biocompatibility. Addition of nitrogen in the structure allows lowering internal stress and improve tribological properties of a-C:H layers. In this work, a-C:N:H layers were deposited from mixture CH4/N2 gases by RF PECVD method. Effects of the nitrogen incorporation on structure and tribological properties of deposited layers were investigated. The structure of layers were characterized by Fourier Transform Infrared spectroscopy (FTIR and X-ray photoelectron spectroscopy (XPS. The friction coefficient, wear resistance of a-C:H:N layers were estimated by tribometer in ball-on-disc configuration. The IR spectra of the obtained layers have demonstrated a presence of nitrogen bonded both to carbon and to hydrogen. A formation of the following bonds has been confirmed: -C≡N, -NH2, -C−NH2, >C=NH. They are all typical for a-C:N:H layers. The tribological tests have shown that the layers reduce the friction coefficient of the polycarbonate (up to 50 % and considerably improve wear resistance.

  11. Copper ion implantation of polycarbonate matrices: Morphological and structural properties

    Energy Technology Data Exchange (ETDEWEB)

    Resta, V., E-mail: vincenzo.resta@le.infn.it; Quarta, G.; Maruccio, L.; Calcagnile, L.

    2014-07-15

    The implantation of 1 MeV {sup 63}Cu{sup +} ions in polycarbonate (PC) matrices has been carried out in order to evaluate the morphological and structural modifications induced in the polymer as a function of the ion fluence in the range 5 × 10{sup 13} ions cm{sup −2} to 1 × 10{sup 17} ions cm{sup −2}. Atomic Force Microscopy analysis reveals a significant roughness increase of the polymer surface only for fluences higher than 5 × 10{sup 16} ions cm{sup −2} with the presence of hillock structures which surface density increases with increasing the ion fluence. X-ray Diffraction measurements of PC implanted with fluences in the range between 5 × 10{sup 15} at cm{sup −2} and 5 × 10{sup 16} at cm{sup −2} reveal an increase of the disorder inside the PC matrix, as a consequence of the damaging process induced by the ion irradiation. Evidences about the presence of exotic phase structures ascribed to both cubic Cu{sub 2}O and cubic Cu have been found.

  12. Fabrication of a flexible polycarbonate/porphyrin film dosimeter for high dose dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Feizi, Shahzad [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of). Radiation Application Research School

    2017-10-01

    Dyed polycarbonate (PC) Radiochromic films with 20 μm thickness were prepared by casting of organic solution of PC containing 0.5 wt.% tetrakis (pentafluorophenyl) porphyrin (TPPF{sub 20}) on a glass petri dish. Characterization of the film as a routine dosimeter was studied. On subjecting PC/TPPF{sub 20} film dosimeter to gamma radiation, a gradual decrease in the color of films was observed. The sensitivity of these films and the linearity of dose-response curves were studied under {sup 60}Co γ-rays expose in dose range of 0-100 kGy. The results were compared with the commercial and non-commercial dosimeters. Experimental parameters including humidity, temperature and pre-irradiation (shelf-life) and post-irradiation storage in dark and in indirect sunlight were examined. The maximum absorbance of soret band of TPPF{sub 20} had a bathochromic shift and appeared at 414 nm which remained intact in the investigated dose range. The dyed films characteristics were found to be stable enough in media with high degrees of temperature and humidity. The results indicate that radiation induced decoloration of PC/TPPF{sub 20} films can be reliably used in high dose dosimetry.

  13. A passive monitor for radon using electrochemical track etch detector

    International Nuclear Information System (INIS)

    Massera, G.E.; Hassib, G.M.; Piesch, E.

    1980-01-01

    A passive monitor for radon and its decay products based on the electrochemical etching (ECE) of α-particle tracks on Makrofol is described. The monitor has been constructed in such a way that radon and radon daughters attached to aerosols can easily pass through a chamber while dust, heavy particles and water droplets are collected outside. The decay products are accumulated on the bottom of the chamber and a Makrofol detector foil is fixed on the top to register alpha particles. The ECE condition was maintained to detect alpha particles coming mainly from radon daughters trapped on the bottom of the chamber. The response of the monitor was determined at different exposure conditions and compared with those of some active techniques such as working level meters. The merits of this system are low cost, good sensitivity, portability and reliable, unattended operation. (author)

  14. Growth and morphological analysis of segmented AuAg alloy nanowires created by pulsed electrodeposition in ion-track etched membranes

    Directory of Open Access Journals (Sweden)

    Ina Schubert

    2015-06-01

    Full Text Available Background: Multicomponent heterostructure nanowires and nanogaps are of great interest for applications in sensorics. Pulsed electrodeposition in ion-track etched polymer templates is a suitable method to synthesise segmented nanowires with segments consisting of two different types of materials. For a well-controlled synthesis process, detailed analysis of the deposition parameters and the size-distribution of the segmented wires is crucial.Results: The fabrication of electrodeposited AuAg alloy nanowires and segmented Au-rich/Ag-rich/Au-rich nanowires with controlled composition and segment length in ion-track etched polymer templates was developed. Detailed analysis by cyclic voltammetry in ion-track membranes, energy-dispersive X-ray spectroscopy and scanning electron microscopy was performed to determine the dependency between the chosen potential and the segment composition. Additionally, we have dissolved the middle Ag-rich segments in order to create small nanogaps with controlled gap sizes. Annealing of the created structures allows us to influence their morphology.Conclusion: AuAg alloy nanowires, segmented wires and nanogaps with controlled composition and size can be synthesised by electrodeposition in membranes, and are ideal model systems for investigation of surface plasmons.

  15. Sources of error in etched-track radon measurements and a review of passive detectors using results from a series of radon intercomparisons

    International Nuclear Information System (INIS)

    Ibrahimi, Z.-F.; Howarth, C.B.; Miles, J.C.H.

    2009-01-01

    Etched-track passive radon detectors are a well established and apparently simple technology. As with any measurement system, there are multiple sources of uncertainty and potential for error. The authors discuss these as well as good quality assurance practices. Identification and assessment of sources of error is crucial to maintain high quality standards by a measurement laboratory. These sources can be found both within and outside the radon measurement laboratory itself. They can lead to changes in track characteristics and ultimately detector response to radon exposure. Changes don't just happen during etching, but can happen during the recording or counting of etched-tracks (for example ageing and fading effects on track sensitivity, or focus and image acquisition variables). Track overlap means the linearity of response of detectors will vary as exposure increases. The laboratory needs to correct the calibration curve due to this effect if it wishes to offer detectors that cover a range of exposures likely to be observed in the field. Extrapolation of results to estimate annual average concentrations also has uncertainty associated with it. Measurement systems need to be robust, reliable and stable. If a laboratory is not actively and constantly monitoring for anomalies via internal testing, the laboratory may not become aware of a problem until some form of external testing occurs, eg an accreditation process, performance test, interlaboratory comparison exercise or when a customer has cause to query results. Benchmark standards of accuracy and precision achievable with passive detectors are discussed drawing on trends from the series of intercomparison exercises for passive radon detectors which began in 1982, organised by the National Radiological Protection Board (NRPB), subsequently the Health Protection Agency (HPA).

  16. Separation of polycarbonate and acrylonitrile–butadiene–styrene waste plastics by froth flotation combined with ammonia pretreatment

    International Nuclear Information System (INIS)

    Wang, Chong-qing; Wang, Hui; Liu, Qun; Fu, Jian-gang; Liu, You-nian

    2014-01-01

    Highlights: • Ammonia treatment changes selectively floatability of PC. • The effects of ammonia on PC were investigated through contact angle and XPS. • Reactions between ammonia and PC surface make PC more hydrophilic. • PC and ABS mixtures with different particle sizes were separated effectively. - Abstract: The objective of this research is flotation separation of polycarbonate (PC) and acrylonitrile–butadiene–styrene (ABS) waste plastics combined with ammonia pretreatment. The PC and ABS plastics show similar hydrophobicity, and ammonia treatment changes selectively floatability of PC plastic while ABS is insensitive to ammonia treatment. The contact angle measurement indicates the dropping of flotation recovery of PC is ascribed to a decline of contact angle. X-ray photoelectron spectroscopy demonstrates reactions occur on PC surface, which makes PC surface more hydrophilic. Separation of PC and ABS waste plastics was conducted based on the flotation behavior of single plastic. At different temperatures, PC and ABS mixtures were separated efficiently through froth flotation with ammonia pretreatment for different time (13 min at 23 °C, 18 min at 18 °C and 30 min at 23 °C). For both PC and ABS, the purity and recovery is more than 95.31% and 95.35%, respectively; the purity of PC and ABS is up to 99.72% and 99.23%, respectively. PC and ABS mixtures with different particle sizes were separated effectively, implying that ammonia treatment possesses superior applicability

  17. Separation of polycarbonate and acrylonitrile–butadiene–styrene waste plastics by froth flotation combined with ammonia pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chong-qing; Wang, Hui, E-mail: huiwang1968@163.com; Liu, Qun; Fu, Jian-gang; Liu, You-nian, E-mail: liuyounian@csu.edu.cn

    2014-12-15

    Highlights: • Ammonia treatment changes selectively floatability of PC. • The effects of ammonia on PC were investigated through contact angle and XPS. • Reactions between ammonia and PC surface make PC more hydrophilic. • PC and ABS mixtures with different particle sizes were separated effectively. - Abstract: The objective of this research is flotation separation of polycarbonate (PC) and acrylonitrile–butadiene–styrene (ABS) waste plastics combined with ammonia pretreatment. The PC and ABS plastics show similar hydrophobicity, and ammonia treatment changes selectively floatability of PC plastic while ABS is insensitive to ammonia treatment. The contact angle measurement indicates the dropping of flotation recovery of PC is ascribed to a decline of contact angle. X-ray photoelectron spectroscopy demonstrates reactions occur on PC surface, which makes PC surface more hydrophilic. Separation of PC and ABS waste plastics was conducted based on the flotation behavior of single plastic. At different temperatures, PC and ABS mixtures were separated efficiently through froth flotation with ammonia pretreatment for different time (13 min at 23 °C, 18 min at 18 °C and 30 min at 23 °C). For both PC and ABS, the purity and recovery is more than 95.31% and 95.35%, respectively; the purity of PC and ABS is up to 99.72% and 99.23%, respectively. PC and ABS mixtures with different particle sizes were separated effectively, implying that ammonia treatment possesses superior applicability.

  18. Uranium analysis in water flowing by the nuclear track detection method on solid dielectric materials

    International Nuclear Information System (INIS)

    Arambula, H.

    1981-01-01

    The objective of this experiment was threefold: to study the content of uranium in tap and spring water, to establish a technique for the quantitative analysis for the presence of uranium in liquids, and to test the qualities as detector fission fragments of three solid insulator materials using the nuclear tracks register method. The latter allows for the measurement of concentrations of fissile elements up to 10 -12 gr/gm employing (n, f.f.) reactions. The test samples were of tap water and of water from six fresh water springs located in San Luis Potosi and Guanajuato. Glass, lexan polycarbonate and muscovite mica were the detector materials used. The technique consisted in evaporating the water from the test samples, which had been previously placed upon the detector materials, and in doing the same for the standard control sample solutions having known concentrations of uranium. All the samples were then irradiated with thermal neutrons, and the 235 U, present in the samples, fissioned. The fission fragments produced permanent damage on the detectors, known as latent tracks. A specific corroding chemical was then applied to each detector which caused the latent tracks to dissolve into grooves. Known as etching tracks, these grooves were microscopically visible and could be measured for track density (tracks/mm 2 ). The concentrations of uranium present in the test samples were measured by comparing the track densities of the test samples with those of the standard control samples. The concentration of uranium found in the spring water samples ranged from 0.09 to 0.89 μqr.U/1, and those of tap water, from 0.18 to 0.19 μqr U/1. Lexan polycarbonate and muscovite mica proved to be better, as detectors, than glass. Glass for quantitative analysis, we found not recommendable as a detector material because of its alterable composition in the presence of uranium. (author)

  19. Fabrication of different pore shapes by multi-step etching technique in ion-irradiated PET membranes

    Science.gov (United States)

    Mo, D.; Liu, J. D.; Duan, J. L.; Yao, H. J.; Latif, H.; Cao, D. L.; Chen, Y. H.; Zhang, S. X.; Zhai, P. F.; Liu, J.

    2014-08-01

    A method for the fabrication of different pore shapes in polyethylene terephthalate (PET)-based track etched membranes (TEMs) is reported. A multi-step etching technique involving etchant variation and track annealing was applied to fabricate different pore shapes in PET membranes. PET foils of 12-μm thickness were irradiated with Bi ions (kinetic energy 9.5 MeV/u, fluence 106 ions/cm2) at the Heavy Ion Research Facility (HIRFL, Lanzhou). The cross-sections of fundamental pore shapes (cylinder, cone, and double cone) were analyzed. Funnel-shaped and pencil-shaped pores were obtained using a two-step etching process. Track annealing was carried out in air at 180 °C for 120 min. After track annealing, the selectivity of the etching process decreased, which resulted in isotropic etching in subsequent etching steps. Rounded cylinder and rounded cone shapes were obtained by introducing a track-annealing step in the etching process. Cup and spherical funnel-shaped pores were fabricated using a three- and four-step etching process, respectively. The described multi-step etching technique provides a controllable method to fabricate new pore shapes in TEMs. Introduction of a variety of pore shapes may improve the separation properties of TEMs and enrich the series of TEM products.

  20. Experimental Study and Modelling of Poly (Methyl Methacrylate) and Polycarbonate Compressive Behavior from Low to High Strain Rates

    Science.gov (United States)

    El-Qoubaa, Z.; Colard, L.; Matadi Boumbimba, R.; Rusinek, A.

    2018-03-01

    This paper concerns an experimental investigation of Polycarbonate and Poly (methyl methacrylate) compressive behavior from low to high strain rates. Experiments were conducted from 0.001/s to ≈ 5000/s for PC and from 0.001/s to ≈ 2000/s for PMMA. The true strain-stress behavior is established and analyzed at various stain rates. Both PC and PMMA mechanical behavior appears as known, to be strain rate and temperature dependent. The DSGZ model is selected for modelling the strain-stress curves while the yield stress is reproduced using the cooperative model and a modified Eyring equation based on Eyring first process theory. All the three models predictions are in agreement with experiments performed on PC and PMMA.

  1. The influence of chemical etching time on efficiency of radon detection using CR-39

    Energy Technology Data Exchange (ETDEWEB)

    Reway, Adriana P.; Kappke, Jaqueline; Narloch, Danielle C., E-mail: adrireway@hotmail.com, E-mail: jaquelinekappke@gmail.com, E-mail: daninarloch@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Del Claro, Flavia; Paschuk, Sergei A., E-mail: flaviadelclaro@gmail.com, E-mail: spaschuk@gmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Programa de Pos-Graduaca em Engenharia Eletrica e Informatica Industrial; Correa, Janine N., E-mail: janine_nicolosi@hotmail.com [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Construcao Civil

    2015-07-01

    Natural radiation is the principal source of human exposure to ionizing radiation. Radon is noble radioactive gas that emanates from the soil and rocks entering the atmosphere of dwellings where it could be accumulated. The inhalation of {sup 222}Rn represents a significant health risk. Solid-State Nuclear Track Detectors (SSNTD) represents an efficient method for alpha particle detection and measurements of the activity concentration of {sup 222}Rn. The aim of present work was to study the etching time impact on CR-39 efficiency in radon activity measurements. The investigation was performed using 80 CR-39 detectors, which were exposed to a source of radon. After the exposition, alpha particle tracks development was achieved by chemical etching using 6.25M NaOH solution and ethanol (2%) at 70°C. Etching alpha particle tracks were identified and counted manually using the optical microscope with magnification of 100x and glass overlay mask. The etching time ranged from 7 to 14 hours. The results show that there is an increase in the number of visible tracks with increased etching time. The number of traces obtained for 7 hours and 8 hours of revelation was 1430 +/- 90 and 2090 +/- 160, respectively. However, for etching time of 13 and 14 hours was not observed statistical increase in the number of visible tracks. The number of tracks in this situation was 3630 +/- 180 and 3870 +/- 160 to 13 and 14 hours etching. Thus, for assumed etching parameters, the etching optimal time was observed 14 hours. (author)

  2. The influence of chemical etching time on efficiency of radon detection using CR-39

    International Nuclear Information System (INIS)

    Reway, Adriana P.; Kappke, Jaqueline; Narloch, Danielle C.; Del Claro, Flavia; Paschuk, Sergei A.; Correa, Janine N.

    2015-01-01

    Natural radiation is the principal source of human exposure to ionizing radiation. Radon is noble radioactive gas that emanates from the soil and rocks entering the atmosphere of dwellings where it could be accumulated. The inhalation of 222 Rn represents a significant health risk. Solid-State Nuclear Track Detectors (SSNTD) represents an efficient method for alpha particle detection and measurements of the activity concentration of 222 Rn. The aim of present work was to study the etching time impact on CR-39 efficiency in radon activity measurements. The investigation was performed using 80 CR-39 detectors, which were exposed to a source of radon. After the exposition, alpha particle tracks development was achieved by chemical etching using 6.25M NaOH solution and ethanol (2%) at 70°C. Etching alpha particle tracks were identified and counted manually using the optical microscope with magnification of 100x and glass overlay mask. The etching time ranged from 7 to 14 hours. The results show that there is an increase in the number of visible tracks with increased etching time. The number of traces obtained for 7 hours and 8 hours of revelation was 1430 +/- 90 and 2090 +/- 160, respectively. However, for etching time of 13 and 14 hours was not observed statistical increase in the number of visible tracks. The number of tracks in this situation was 3630 +/- 180 and 3870 +/- 160 to 13 and 14 hours etching. Thus, for assumed etching parameters, the etching optimal time was observed 14 hours. (author)

  3. Study of gamma irradiation effects on the etching and optical properties of CR-39 solid state nuclear track detector and its application to uranium assay in soil samples

    International Nuclear Information System (INIS)

    Amol Mhatre; Kalsi, P.C.

    2011-01-01

    The gamma irradiation effects in the dose range of 2.5-43.0 Mrad on the etching and optical characteristics of CR-39 solid state nuclear track detector (SSNTD) have been studied by using etching and UV-Visible spectroscopic techniques. From the measured bulk etch rates at different temperatures, the activation energies for bulk etching at different doses have also been determined. It is seen that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. The optical band gaps of the unirradiated and the gamma -irradiated detectors determined from the UV-Visible spectra were found to decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation. The present studies can be used for the estimation of gamma dose in the range of 2.5-43.0 Mrad and can also be used for estimating track registration efficiency in the presence of gamma dose. The CR-39 detector has also been applied for the assay of uranium in some soil samples of Jammu city. (author)

  4. Influences of layer thickness on the compatibility and physical properties of polycarbonate/polystyrene multilayered film via nanolayer coextrusion

    Science.gov (United States)

    Cheng, Junfeng; Chen, Zhiru; Zhou, Jiaqi; Cao, Zheng; Wu, Dun; Liu, Chunlin; Pu, Hongting

    2018-05-01

    The effects of layer thickness on the compatibility between polycarbonate (PC) and polystyrene (PS) and physical properties of PC/PS multilayered film via nanolayer coextrusion are studied. The morphology of multilayered structure is observed using a scanning electron microscope. This multilayered structure may have a negative impact on the transparency, but it can improve the water resistance and heat resistance of film. To characterize the compatibility between PC and PS, differential scanning calorimetry is used to measure the glass transition temperature. The compatibility is found to be improved with the decrease of layer thickness. Therefore, the viscosity of multilayered film is also reduced with the decrease of layer thickness. In addition, the multilayered structure can improve the tensile strength with the increase of layer numbers. Because of the complete and continuous layer structure of PC, the PC/PS multilayered film can retain its mechanical strength at the temperature above Tg of PS.

  5. Physical and Mechanical Characteristics of Kevlar Fiber-Reinforced PC/ABS Composites

    Directory of Open Access Journals (Sweden)

    Kuljira Sujirote

    2012-01-01

    Full Text Available In this research, the composites between polycarbonate (PC and acrylonitrile-butadiene-styrene (ABS alloy and Kevlar fiber were prepared. The flexural and tensile properties of PC/ABS alloy and its composites were determined using a universal testing machine. The synergistic behavior of flexural modulus was observed for all regions of PC contents, while the synergism of flexural strength and tensile strength were found in some PC contents. It was found that the optimum weight ratio of PC:ABS was 60:40. In the Kevlar Fiber-reinforced PC/ABS composite system at PC:ABS of 60:40, both flexural modulus and strength were increased with matrix contents. Additionally, the flexural strength drastically increased with the matrix content and then reached the maximum value of 167 MPa at the matrix content of 33.4 wt%. The results from peel test, water contact measurement, and scanning electron microscopy (SEM reveal that the interfacial adhesion between the Kevlar fiber and the polymer matrix could be improved by increasing the PC content in the matrix.

  6. Etching characteristics of nuclear tracks in CR-39 plastics

    International Nuclear Information System (INIS)

    Tsuruta, Takao; Isobe, Ginko.

    1984-01-01

    In using CR-39 plastics for individual neutron dosimeters, changes of etching efficiency cause significant error in dose estimation. Etching efficiency is subject to a number of parameters. In this study the influences of the parameters were examined by measuring the diameters of etch-pits formed by alpha-particles and enlarged by aqueous solutions of 25-35% KOH at 55-65 0 C for 4 hr. It has been observed that diameter changes at the rate of 8.3%/ 0 C in temperature, 8.2%/wt% in concentration and -0.60%/day in time after preparation of etchant. The diameter is unaffected by the supplying of up to 280ml/l, of distilled water for evaporation of etchant or by increase up to 5g/l of CR-39 dissolved in etchant. The magnitude of possible error has been estimated by parameter as well as in general, so as to obtain suggestions for improving etching treatment. (author)

  7. Etching kinetics of swift heavy ion irradiated silicone rubber with insoluble additives or reaction products

    International Nuclear Information System (INIS)

    Fink, D.; Mueller, M.; Petrov, A.; Farenzena, L.; Behar, M.; Papaleo, R.P.

    2003-01-01

    It is normally understood as a basic precondition of the etching of swift heavy ion tracks in polymers that both the additives and etching products are soluble in the etchant. If this is not given, the polymer surface may be gradually blocked by the deposition of the insoluble material that acts as a diffusion barrier for the penetration of fresh etchant into the tracks, and therefore the effective track etching speed will gradually be reduced. The etching kinetics is developed for that case, and the theory is compared with first experimental findings. For that purpose we have taken commercial silicone rubber foils as test materials, that were irradiated with GeV heavy ions through a mask at a fluence that corresponds to the onset of track overlapping. After etching with NaOH, the corresponding etching speed was recorded via the reduction of the foil thickness. The etching speed is seen to decrease with exposure time, in parallel to the development of an insoluble surface layer. It is discussed how to prevent that surface blocking, to maintain a high etching speed

  8. Preparation of fluoropolymer-based ion-track membranes. Structure of latent tracks and pretreatment effect

    International Nuclear Information System (INIS)

    Yamaki, Tetsuya; Nuryanthi, Nuryanthi; Koshikawa, Hiroshi; Sawada, Shinichi; Hakoda, Teruyuki; Hasegawa, Shin; Asano, Masaharu; Maekawa, Yasunari

    2012-01-01

    High-energy heavy-ion induced damage, called latent tracks m organic polymers can sometimes be etched out chemically to give submicro- and nano-sized pores. Our focus is placed on ion-track membranes of poly(vinylidene fluoride) (PVDF), a type of fluoropolymer, which were previously considered as a matrix of polymer electrolyte fuel-cell membranes. There have been no optimized methods of preparing the PVDF-based ion-track membranes. We thus examined chemical structures of the defects created in the track, and accordingly, presented a pretreatment technique for achieving more efficient track etching. A 25 μm-thick PVDF film was bombarded with 1.1 GeV 238 U or 450 MeV 129 Xe ions. In the multi-purpose chamber, degradation processes were monitored in-situ by FT-IR spectroscopy and residual gas analysis as a function of the fluence up to 6.0 x 10 11 ions/cm 2 . The films irradiated at 8 ions/cm 2 were etched in a 9 M KOH aqueous solution at 80degC. We also performed the conductometric etching, which allows monitoring of pore evolution versus etching time by recording the electrical conductance through the membrane. At fluences above 1 x 10 10 ions/cm 2 , the film showed two new absorption bands identified as double-bond stretching vibrations of in-chain unsaturations -CH=CF- and fluorinated vinyl groups -CF 2 CH=CF 2 . These defects would result from the evolution of HF. The knowledge of the solubility in a permanganate alkaline solution and our preliminary experiment suggested the importance of oxidized tracks for the easy introduction of the etching agent. We finally found that the pretreatment with ozone could oxidize the double bonds in the tracks, thereby vigorously promoting track etching before breakthrough. (author)

  9. Investigation of the various factors affecting the response of passive configuration track etch dosimeters to working level hour exposure in radon and radon daughter atmospheres. Final report

    International Nuclear Information System (INIS)

    Lovett, D.B.

    1976-01-01

    The work described in this report was directed toward identifying and devising methods to minimize the previously observed variability between working level hour exposures and the alpha particle track densities resulting on Track Etch films exposed to mine atmospheres containing radon and radon daughters. The disequilibrium between radon and its daughters was shown to directly affect the Track Etch film calibration factor. The wide range of disequilibrium states possible in mine situations amply explains the variability in the previous tests. A file of published mine atmosphere composition data was compiled and was used, along with atmospheric compositions derived from several theoretical models of the atmospheric behavior, to evaluate the variability of several dosimeter configurations and concepts

  10. Influence of flavour absorption on oxygen permentation through LDPE, PP, PC and PET plastics food packaging

    NARCIS (Netherlands)

    Willige, van R.W.G.; Linssen, J.P.H.; Meinders, M.B.J.; Stege, van der H.J.; Voragen, A.G.J.

    2002-01-01

    The effect of flavour absorption on the oxygen permeability of low-density polyethylene (LDPE), polypropylene (PP), polycarbonate (PC) and polyethylene terephthalate (PET) was studied using an isostatic continuous flow system. Polymer samples were exposed to a model solution containing limonene,

  11. Influence of flavour absorption by food-packaging materials (low-density polyethylene, polycarbonate and polyethylene terephthalate) on taste perception of a model solution and orange juice

    NARCIS (Netherlands)

    Willige, van R.W.G.; Linssen, J.P.H.; Legger, A.; Voragen, A.G.J.

    2003-01-01

    The influence of flavour absorption by low-density polyethylene (LDPE), polycarbonate (PC) and polyethylene terephthalate (PET) on taste perception of a model solution containing seven flavour compounds and orange juice in glass bottles was studied with and without pieces of the respective plastic

  12. Morphology Evolution of Polycarbonate-Polystyrene Blends During Compounding

    DEFF Research Database (Denmark)

    Chuai, Chengzhi; Almdal, Kristoffer; Johannsen, Ib

    2001-01-01

    The morphology evolution of polycarbonate-polystyrene (PC/PS) blends during the compounding process in three blending methods of industrial relevance, namely melt blending, re-melt blending in a twin-screw extruder and tri-melt blending in an injection-moulding machine, was investigated using......-empirical model. The results show that the formation of co-continuous morphology strongly depends on blend composition and melt blending method, whereas the model prediction for phase inversion deviates from the experimental values. Further, we found that the initial mechanism of morphology evolution involves...... scanning electron microscopy (SEM) Co examine nine blend compositions. Blends were prepared at compositions where phase inversion was expected to occur according to model predictions. The experimental results were compared to the values of the point of phase inversion calculated with the semi...

  13. Determining of the track parameters in solid state nuclear track detectors Cr 39 due to alpha particles

    International Nuclear Information System (INIS)

    Kostic, D.; Nikezic, D.

    1997-01-01

    An equation of the etch pit wall is proposed to be used for simulation of the track growth and calculating the major and the minor axis of etch pit opening. Dependence on the following parameters is set up: distance along a track from the point where the particle entered the detector, ratio of the track etch wall to the bulk etch rate, integration constant determined from particle penetration depth and normal distance from the particle trajectory to the etch pit wall. The corresponding computer program was written. The input parameters of this program are: alpha particles energy, incidence angle and removed layer; the output gives track parameters. The results obtained by this method are compared to another approach given by Somogy and Szalay (1973) and a reasonably good agreement is found. (author)

  14. Effects of Phase Separation Behavior on Morphology and Performance of Polycarbonate Membranes

    Science.gov (United States)

    Idris, Alamin; Man, Zakaria; Maulud, Abdulhalim S.; Khan, Muhammad Saad

    2017-01-01

    The phase separation behavior of bisphenol-A-polycarbonate (PC), dissolved in N-methyl-2-pyrrolidone and dichloromethane solvents in coagulant water, was studied by the cloud point method. The respective cloud point data were determined by titration against water at room temperature and the characteristic binodal curves for the ternary systems were plotted. Further, the physical properties such as viscosity, refractive index, and density of the solution were measured. The critical polymer concentrations were determined from the viscosity measurements. PC/NMP and PC/DCM membranes were fabricated by the dry-wet phase inversion technique and characterized for their morphology, structure, and thermal stability using field emission scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis, respectively. The membranes’ performances were tested for their permeance to CO2, CH4, and N2 gases at 24 ± 0.5 °C with varying feed pressures from 2 to 10 bar. The PC/DCM membranes appeared to be asymmetric dense membrane types with appreciable thermal stability, whereas the PC/NMP membranes were observed to be asymmetric with porous structures exhibiting 4.18% and 9.17% decrease in the initial and maximum degradation temperatures, respectively. The ideal CO2/N2 and CO2/CH4 selectivities of the PC/NMP membrane decreased with the increase in feed pressures, while for the PC/DCM membrane, the average ideal CO2/N2 and CO2/CH4 selectivities were found to be 25.1 ± 0.8 and 21.1 ± 0.6, respectively. Therefore, the PC/DCM membranes with dense morphologies are appropriate for gas separation applications. PMID:28379173

  15. Effects of Phase Separation Behavior on Morphology and Performance of Polycarbonate Membranes

    Directory of Open Access Journals (Sweden)

    Alamin Idris

    2017-04-01

    Full Text Available The phase separation behavior of bisphenol-A-polycarbonate (PC, dissolved in N-methyl-2-pyrrolidone and dichloromethane solvents in coagulant water, was studied by the cloud point method. The respective cloud point data were determined by titration against water at room temperature and the characteristic binodal curves for the ternary systems were plotted. Further, the physical properties such as viscosity, refractive index, and density of the solution were measured. The critical polymer concentrations were determined from the viscosity measurements. PC/NMP and PC/DCM membranes were fabricated by the dry-wet phase inversion technique and characterized for their morphology, structure, and thermal stability using field emission scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis, respectively. The membranes’ performances were tested for their permeance to CO2, CH4, and N2 gases at 24 ± 0.5 °C with varying feed pressures from 2 to 10 bar. The PC/DCM membranes appeared to be asymmetric dense membrane types with appreciable thermal stability, whereas the PC/NMP membranes were observed to be asymmetric with porous structures exhibiting 4.18% and 9.17% decrease in the initial and maximum degradation temperatures, respectively. The ideal CO2/N2 and CO2/CH4 selectivities of the PC/NMP membrane decreased with the increase in feed pressures, while for the PC/DCM membrane, the average ideal CO2/N2 and CO2/CH4 selectivities were found to be 25.1 ± 0.8 and 21.1 ± 0.6, respectively. Therefore, the PC/DCM membranes with dense morphologies are appropriate for gas separation applications.

  16. Influence factors on etching rate of PET nuclear pore membrane

    International Nuclear Information System (INIS)

    Zuo Zhenzhong; Wu Zhendong; Liang Haiying; Ju Wei; Chen Dongfeng; Fu Yuanyong; Qu Guopu

    2014-01-01

    Background: The nuclear pore membrane is a kind of liquid filtration material manufactured by irradiation and chemical etching. Various conditions in etch process have a great influence on etch rate. Purpose: The influence factors of concentration and temperature of etch solution and the irradiation energy of heavy ions on etch rate was studied. Methods: Four layers of PET (polyethylene terephthalate) films were stacked together and were irradiated with 140-MeV 32 S ions at room temperature under vacuum conditions. Utilizing conductivity measurement technique, the electrical current changes through the u:radiated PET film were monitored during etching, from which the breakthrough time and therefore the track etching rate was calculated. Results: The results show that there is an exponential correlation between etch rate and temperature, and a linear correlation between etch rate and concentration. The track etching rate increases linearly with energy loss rate. Empirical formula for the bulk etching rate as a function of etchant concentration and temperature was also established via fitting of measurements. Conclusion: It is concluded that by using 1.6-MeV·u -1 32 S ions, PET nuclear pore membrane with cylindrical pore shape can be prepared at 85℃ with etchant concentration of l mol·L -1 . (authors)

  17. Alpha-particle response characteristics of CR-39

    International Nuclear Information System (INIS)

    Abou El-Khier, A.A.; Gaber, M.; El-Khatib, A.M.; Fawzy, M.A.

    1987-01-01

    The form of the response curve of the polycarbonate CR-39 for α-particles at relatively low energies has been established. The investigation included measurements of both bulk- and track-etch rates. The latter was measured as a function of α-particle energies. (author)

  18. Photocatalytic segmented nanowires and single-step iron oxide nanotube synthesis: Templated electrodeposition as all-round tool

    NARCIS (Netherlands)

    Maas, M.G.; Rodijk, E.J.B.; Maijenburg, A.W.; ten Elshof, Johan E.; Blank, David H.A.; Nielsch, K.; Fontcuberta i Morral, A.; Holt, J.K.; Thomson, C.V.

    2010-01-01

    Templated electrodeposition was used to synthesize silver-zinc oxide nanowires and iron oxide (Fe2O3) nanotubes in polycarbonate track etched (PCTE) membranes. Metal/oxide segmented nanowires were made to produce hydrogen gas from a water/methanol mixture under ultraviolet irradiation. It was

  19. High fidelity computational characterization of the mechanical response of thermally aged polycarbonate

    Science.gov (United States)

    Zhang, Zesheng; Zhang, Lili; Jasa, John; Li, Wenlong; Gazonas, George; Negahban, Mehrdad

    2017-07-01

    A representative all-atom molecular dynamics (MD) system of polycarbonate (PC) is built and conditioned to capture and predict the behaviours of PC in response to a broad range of thermo-mechanical loadings for various thermal aging. The PC system is constructed to have a distribution of molecular weights comparable to a widely used commercial PC (LEXAN 9034), and thermally conditioned to produce models for aged and unaged PC. The MD responses of these models are evaluated through comparisons to existing experimental results carried out at much lower loading rates, but done over a broad range of temperatures and loading modes. These experiments include monotonic extension/compression/shear, unilaterally and bilaterally confined compression, and load-reversal during shear. It is shown that the MD simulations show both qualitative and quantitative similarity with the experimental response. The quantitative similarity is evaluated by comparing the dilatational response under bilaterally confined compression, the shear flow viscosity and the equivalent yield stress. The consistency of the in silico response to real laboratory experiments strongly suggests that the current PC models are physically and mechanically relevant and potentially can be used to investigate thermo-mechanical response to loading conditions that would not easily be possible. These MD models may provide valuable insight into the molecular sources of certain observations, and could possibly offer new perspectives on how to develop constitutive models that are based on better understanding the response of PC under complex loadings. To this latter end, the models are used to predict the response of PC to complex loading modes that would normally be difficult to do or that include characteristics that would be difficult to measure. These include the responses of unaged and aged PC to unilaterally confined extension/compression, cyclic uniaxial/shear loadings, and saw-tooth extension/compression/shear.

  20. Surface modification of carbon black for the reinforcement of polycarbonate/acrylonitrile–butadiene–styrene blends

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B.B. [School of Chemical Engineering, Fuzhou University, Fuzhou 350108 (China); Chen, Y. [School of materials Engineering, Fujian Agriculture and Forestry University, Fuzhou 350002 (China); Wang, F. [School of Chemical Engineering, Fuzhou University, Fuzhou 350108 (China); Hong, R.Y., E-mail: rhong@suda.edu.cn [School of Chemical Engineering, Fuzhou University, Fuzhou 350108 (China); College of Chemistry, Chemical Engineering and Materials Science & Key Laboratory of Organic Synthesis of Jiangsu Province, Soochow University, SIP, Suzhou 215123 (China)

    2015-10-01

    Highlights: • CB was modified through the method of oxygen plasma treatment. • Surface modified CB applied in PC/ABS blends. • The treated CB showed better compatibility in PC/ABS blends. • PC/ABS blends with treated CB showed better mechanical and thermal properties. - Abstract: The surface of carbon black was modified by oxygen plasma treatment for different times (10, 20 and 30 min). In order to increase the applicability of carbon black (CB), functional groups were grafted on the generally inert surface of CB using oxygen plasma. The surface compositional and structural changes that occurred on CB were investigated by SEM, FT-IR, Raman spectroscopy, XRD and BET. Subsequently, CB reinforced polycarbonate (PC)/acrylonitrile-butadiene-styrene (ABS) composites were prepared by internal batch mixing with the addition of different content of CB (3, 6, 9, 12 wt%). The morphology of PC/ABS/CB (7/3/6 wt%) nanocomposites was studied through scanning electron microscopy. Observations of SEM images showed that the plasma-treated CB had a better dispersion in the blend matrix. Moreover, the mechanical tests showed that the tensile strength and impact strength were improved by 32.4% and 22.5%, respectively, with the addition of plasma-treated CB. In addition, the thermal stability was improved and glass transition temperatures of both PC and ABS increased as shown by TGA and DSC, respectively.

  1. Gamma dosimetry with CR-39 etch track detector

    International Nuclear Information System (INIS)

    Matiullah; Dogar, A.H.; Ahmad, N.; Amin, M.; Kudo, Katsuhisa

    1999-01-01

    To preserve and improve the safety of food for commercial purposes, it is exposed to high gamma-ray doses. The gamma-ray doses used for this purpose range from 0.15 kGy to 50 kGy. At such high doses, the etching characteristics of CR-39 are severely affected. This property, therefore, can be used to develop a CR-39-based gamma dosimeter. In this context, systematic studies were carried out and the bulk etching rate was determined as a function of gamma-ray dose using different methods. (author)

  2. Electrophoretic growth of lead zirconate titanate nanorods

    Energy Technology Data Exchange (ETDEWEB)

    Limmer, S.J.; Seraji, S.; Forbess, M.J.; Wu Yun; Chou, T.P.; Nguyen, C.; Cao Guozhong [Washington Univ., Seattle, WA (United States). Dept. of Materials Science and Engineering

    2001-08-16

    Nanorods of lead zirconate titanate (PZT)-a ferro- and piezoelectric material-up to 10 {mu}m in length and 70 to 150 nm in diameter are produced by sol-gel electrophoresis of PZT in a track-etched polycarbonate membrane, which is used as a template. (orig.)

  3. Liquid nitrogen enhancement of partially annealed fission tracks in glass

    International Nuclear Information System (INIS)

    Pilione, L.J.; Gold, D.P.

    1976-01-01

    It is known that the number density of fission tracks in solids is reduced if the sample is heated before chemical etching, and the effect of annealing must be allowed for before an age can be assigned to the sample. The extent of annealing can be determined by measuring the reduction of track parameters (diameter and/or length) and comparison with unannealed tracks. Correct ages can be obtained by careful calibration studies of track density reduction against track diameter or length reduction at different annealing temperatures and times. For crystallised minerals, however, the resulting correction techniques are not generally valid. In the experimental work described glass samples were partially annealed and then immersed in liquid N 2 for various periods, and it was shown that the properties of the glass and the track parameters could be altered so as to observe tracks that would normally be erased by annealing. The results of track density measurements against liquid N 2 immersion times are shown graphically. A gain of about 40% was achieved after 760 hours immersion time. The size of the tracks was not noticeably affected by the immersion. It was thought that thermal shock might be the cause of the track enhancement, but it was found that repeated immersion for about 2 hours did not lead to an increase in track density. Other studies suggest that the mechanism that erases the tracks through annealing may be partially reversed when the temperature of the sample is significantly lowered for a sufficient length of time. Further work is under way to find whether or not the process of enhancement is a reversal of the annealing process. Similar enhancement effects using liquid N 2 have been observed for d-particle tracks in polycarbonate detectors. (U.K.)

  4. Range measurements and track kinetics in Dielectric Nuclear Track Detectors (DNTDs)

    Energy Technology Data Exchange (ETDEWEB)

    Aframian, A

    1981-01-01

    Observations of nuclear track development profiles and the kinetics of etched tracks in sensitive dielectric nuclear track detectors indicate three separate phases: the inception phase or the cone phase, the transition phase and the sphere phase. Continued etching of the sphere phase to through-tracks yields accurate range data for particles of different masses and energies and minimum critical angles of registration for each particle. The present results show an energy resolution of 40 keV (fwhm) for 5.48 MeV alpha-particles emitted from Am-241.

  5. Radon and radon-daughter exposure measurements by through-etched track registration in cellulose nitrate

    International Nuclear Information System (INIS)

    Knoefell, T.M.J.; Silva Estrada, J.J. da; Tavares, O.A.P.; Martins, J.B.

    1981-01-01

    The use of cellulose nitrate films LR-115 type II (Kodak-Pathe) as a practical, exposure integrating device to measure the level of exposure to alpha particles in atmospheres which contain radon and radon-daughter products is investigated. The analysis of a number of cellulose nitrate films that have been exposed to calibrated radon test-chamber atmospheres has indicated good correlations between through-etched track density p and integrated alpha-particle exposure Σa (Working-Level-Hour). It is shown that the response of the cellulose nitrate detector to radon-daughter alpha-particle exposures is linear, and that reliable conservative estimations of the Working-Level-Hour can be obtained from Σa = 3.0(p-b), where p is expressed in tracks/mm 2 (b is the background level). These results recommend the use of the special red cellulose nitrate films as a convenient dosimeter for monitoring radioactive contaminants in mine atmospheres. (Author) [pt

  6. Evaluation of frictional forces of polycarbonate self-ligating brackets.

    Science.gov (United States)

    Fernandes, Daniel J; Miguel, José Augusto M; Quintão, Catia C A; Elias, Carlos N

    2010-01-01

    To evaluate the frictional forces generated by ceramic- (Opal, Ultradent) and glass-fiber-reinforced polycarbonate self-ligating brackets (Oyster, Gestenco) and compare the effectiveness of these ligatureless systems with glass-fiber-reinforced polycarbonate conventional brackets (Blonde, Gestenco). The hypothesis is that there is no difference between frictional forces generated by ceramic- and glass-fiber-reinforced polycarbonate self-ligating and glass-fiber-reinforced polycarbonate conventional brackets. Twelve preadjusted 0.022 3 0.028-inch maxillary canine brackets were tested, divided into three groups: Opal, Oyster, and Blonde. Frictional tests were conducted with the Emic DL 10000 testing machine with a 20 N loadcell for 40 seconds at a 0.5 cm/min speed. Each bracket-wire combination was tested five times. The data generated were analyzed by parametric analysis of variance (one-way ANOVA) and Bonferroni tests. Analysis of variance indicated significant differences for the three groups (Pfrictional forces of the Oyster glass-fiber-reinforced polycarbonate self-ligating brackets were significantly lower (37.0 ± 8.9 cN) than those of the Opal ceramic-reinforced polycarbonate self-ligating brackets (49.5 ± 10.1 cN), while the Blonde glass-fiber-reinforced conventional bracket frictional forces were 105.8 ± 6.4 cN. Oyster glass-fiber-reinforced polycarbonate brackets produced less friction than Opal ceramic-reinforced polycarbonate brackets. The polycarbonate ligatureless system showed significantly lower frictional forces compared to Blonde conventional polycarbonate brackets tied with elastomeric ligatures. The study rejected the initial hypothesis because there are significant differences of frictional forces among the tested systems. © 2010 BY QUINTESSENCE PUBLISHING CO, INC.

  7. Factors affecting the adhesion of microwave plasma deposited siloxane films on polycarbonate

    International Nuclear Information System (INIS)

    Muir, B.W.; Thissen, H.; Simon, G.P.; Murphy, P.J.; Griesser, H.J.

    2006-01-01

    The effects of a radiofrequency oxygen plasma pretreatment and residual water content in the substrate on the adhesion of microwave plasma deposited tetramethyldisiloxane thin films on Bisphenol-A polycarbonate (BPA-PC) were investigated. Samples were characterised using a crosshatch adhesion test, optical and electron microscopy, and X-ray photoelectron spectroscopy. It was found that the use of a low power (5 W) and low treatment time (0.1 s) oxygen plasma can improve adhesion while greater treatment times (1-30 s) and higher oxygen plasma powers (40 W) resulted in a decreased level of adhesion. In addition, it was shown that a BPA-PC water content greater than 90 ppm resulted in rapid adhesion failure of deposited films at the substrate-plasma polymer interface during outdoor weathering. All films degraded substantially when exposed to environmental weathering, indicating ageing reactions within the plasma polymer films themselves, and at the bulk polymer-coating interface

  8. Free volume changes in mechanically milled PS and PC studied by positron annihilation lifetime spectroscopy (PALS)

    NARCIS (Netherlands)

    Günther-Schade, K.; Castricum, H.L.; Ziegler, H.J.; Bakker, H.; Faupel, F.

    2004-01-01

    The effect of mechanical milling on free volume was studied by means of positron annihilation lifetime spectroscopy (PALS) in polystyrene (PS) as a typical brittle polymer and in polycarbonate (PC) as a tough representative. Long-time milling increases the free volume, while a decrease is observed

  9. Dielectric and Energy Storage Properties of the Heterogeneous P(VDF-HFP)/PC Composite Films

    Science.gov (United States)

    Zhao, Xiaojia; Peng, Guirong; Zhan, Zaiji

    2017-12-01

    Polymer-based materials with a high discharge energy and low energy loss have attracted considerable attention for energy storage applications. A new class of polymer-based composite films composed of amorphous polycarbonate (PC) and poly(vinylidene fluoride-hexafluoropropylene) [P(VDF-HFP)] has been fabricated by simply solution blending followed by thermal treatment under vacuum. The results show that the diameter of the spherical phase for PC and the melting temperature of P(VDF-HFP) increase, and the crystallinity and crystallization temperature of P(VDF-HFP) decrease with increasing PC content. The phase transition from the polar β phase to weak polarity γ phase is induced by PC addition. Moreover, the Curie temperature of the P(VDF-HFP)/PC composite films shifts to a lower temperature. With the addition of PC, the permittivity, polarization and discharge energy of the P(VDF-HFP)/PC composite films slightly decrease. However, the energy loss is significantly reduced.

  10. Directed Hierarchical Patterning of Polycarbonate Bisphenol A Glass Surface along Predictable Sites

    Directory of Open Access Journals (Sweden)

    Mazen Khaled

    2015-01-01

    Full Text Available This paper reports a new approach in designing textured and hierarchical surfaces on polycarbonate bisphenol A type glass to improve hydrophobicity and dust repellent application for solar panels. Solvent- and vapor-induced crystallization of thermoplastic glass polycarbonate bisphenol A (PC is carried out to create hierarchically structured surfaces. In this approach dichloromethane (DCM and acetone are used in sequence. Samples are initially immersed in DCM liquid to generate nanopores, followed by exposing to acetone vapor resulting in the generation of hierarchical structure along the interporous sites. The effects of exposure time on the size, density, and distance of the generated spherules and gaps are studied and correlated with the optical transmittance and contact angle measurements at the surface. At optimized exposure time a contact angle of 98° was achieved with 80% optical transmittance. To further increase the hydrophobicity while maintaining optical properties, the hierarchical surfaces were coated with a transparent composite of tetraethyl orthosilicate as precursor and hexamethyldisilazane as silylation agent resulting in an average contact angle of 135.8° and transmittance of around 70%. FTIR and AFM characterization techniques are employed to study the composition and morphology of the generated surfaces.

  11. Gamma radiation effects on polycarbonate-Durolon; A interacao da radiacao gama com o policarbonato Durolon

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Adelina

    1996-12-31

    In this work, the commercial polycarbonate-Durolon, was characterized through measurements of its mechanical, optical viscosimetric and thermal properties, after being irradiated with a {sup 60} Co gamma-source at IPEN-CNEN/SP. These irradiations were carried out different doses and dose rates in air and in vacuum. From the results obtained it was shown that irradiation causes degradation in PC mainly by chain scission, leading to the formation of phenoxy and phenyl radicals which are associated with the yellowness of the material. Both, the concentration of radicals and yellowness of PC increase with the irradiation doses and dose rates. The irradiated PC-Durolon shown a good mechanical stability up to the doses analyzed, but on the other hand, its optical properties do not have the same performance. The viscosity and glass transition temperature of the Durolon decreases with the increase of dose and dose rates. This behavior indicates that main chain scission is the predominant process during irradiation. Furthermore in PC this degradation is higher when the material is irradiated in air, which shows that oxygen also plays an important role in this degradation process. (author). 37 refs., 30 figs., 4 tabs.

  12. Neutron detection using CR-39 and Atomic Force Microscopy (AFM)

    International Nuclear Information System (INIS)

    Vazquez L, C.; Fragoso, R.; Felix, R.; Golzarri, J.I.; Espinosa, G.; Castillo, F.

    2007-01-01

    AFM has been applied in many CR-39 track formation analyses. In this paper, the use of AFM in the neutron detection and analysis of the track formation is reported. The irradiation was made with an 1.5 GBq (0.5 Ci) 241 Am-Be neutron source, with and without a polyethylene radiator. The surface analysis was made to the CR-39 fresh material without irradiation, after the irradiation, and after a very short etching time. The results show important differences between the irradiation, with and without polyethylene radiator, and the latent tracks of the neutron in the CR-39 polycarbonate. The development of track formation after very short etching time and pits characterization were measured too using the AFM facilities. (Author)

  13. Microdosimetry for a carbon ion beam using track-etched detectors

    International Nuclear Information System (INIS)

    Ambrozova, I.; Ploc, O.; Davidkova, M.; Vondracek, V.; Sefl, M.; Stepan, V.; Pachnerova Brabcova, K.; Incerti, S.

    2015-01-01

    Track-etched detectors (TED) have been used as linear energy transfer (LET) spectrometers in heavy ion beams for many years. LET spectra and depth -dose distribution of a carbon ion beam were measured behind polymethylmethacrylate degraders at Heavy Ion Medical Accelerator in Chiba, Japan. The measurements were performed along monoenergetic beam with energy 290 MeV u -1 in different positions: (1) at beam extraction area, (2) at beginning, (3) maximum and (4) behind the Bragg peak region (0, 117, 147 and 151 mm of water-equivalent depth, respectively). The LET spectra inside and outside of the primary ion beam have been evaluated. TED record only heavy charged particles with LET above 8 -10 keV μm -1 , while electrons and ions with lower LET are not detected. The Geant4 simulation toolkit version 4.9.6.P01 has been used to estimate the contribution of non-detected particles to absorbed dose. Presented results demonstrate the applicability of TED for microdosimetry measurements in therapeutic carbon ion beams. (authors)

  14. Radon measurements by etched track detectors applications in radiation protection, earth sciences and the environment

    CERN Document Server

    Durrani, Saeed A

    1997-01-01

    Exposure to radon gas, which is present in the environment naturally, constitutes over half the radiation dose received by the general public annually. At present, the most widely used method of measuring radon concentration levels throughout the world, both in dwellings and in the field, is by etched track detectors - also known as Solid State Nuclear Detectors (SSNTDs). Although this is not only the most widely used method but is also the simplest and the cheapest, yet there is at present no book available on the market globally, devoted exclusively or largely to the methodology of, and deal

  15. Microstructure development in zinc oxide nanowires and iron oxohydroxide nanotubes by cathodic electrodeposition in nanopores

    NARCIS (Netherlands)

    Maas, M.G.; Rodijk, E.J.B.; Maijenburg, A.W.; Blank, David H.A.; ten Elshof, Johan E.

    2011-01-01

    The cathodic electrodeposition of crystalline ZnO nanowires and amorphous FeO(OH) nanotubes in polycarbonate track-etched membranes with pore diameters of 50–200 nm is reported. Nitrate was used as a sacrificial precursor for the electrochemical generation of hydroxyl ions that raised the pH of the

  16. Improved permeation performance and fouling-resistance of Poly(vinyl chloride/Polycarbonate blend membrane with added Pluronic F127

    Directory of Open Access Journals (Sweden)

    Supateekan Pacharasakoolchai

    2014-04-01

    Full Text Available The aim of this work was to prepare and characterize poly(vinyl chloride (PVC/polycarbonate (PC blend membranes for use in ultrafiltration. Pluronic F127 was used as an additive to modify the membrane surface of the PVC/PC blended membranes. The PVC/PC blend membrane was first prepared using the phase inversion method from a casting solution of PVC with small amount of PC in N-methylpyrrolidone (NMP and water as the non-solvent. The morphologies structure and properties, such as tensile strength, water flux, and bovine serum albumin (BSA rejection of the blend membrane were studied. Increased amounts of PC resulted in an increase in the water flux and ability to reject protein. A concentration of 0.75 wt% PC provided the best improvement in tensile strength of blend membrane. Addition of different amounts of pluronic F127 to the casting solution of PVC/PC with a PC concentration of 0.75 wt% resulted in a decrease in the water contact angle that demonstrated the improvement of hydrophilicity of blend membrane. Scanning electron microscopy photographs showed that the modified PVC/PC membranes had a bigger pore volume in the porous sub-layer compared to the PVC/PC control membrane. The PVC/PC membrane with added Pluronic F127 exhibited a much higher flux and rejection of BSA in a protein filtration experiment than the PVC/PC membrane. An increase in flux recovery ratio of PVC/PC/pluronic 127 blend membrane indicated that the modified membranes could reduce membrane fouling useful for ultrafiltration.

  17. Effect of gamma radiation and nano-zinc oxide content on the properties of recycled polycarbonate

    International Nuclear Information System (INIS)

    Carvalho, Ana Luiza F.; Mendes, Luis C.; Cestari, Sibele P.

    2015-01-01

    In order to promote the barrier action to the ultraviolet radiation and increase of mechanical characteristics, nanocomposites of recycled polycarbonate (rPC) and nano-zinc oxide (nZnO) containing 1, 2 and 3 % (wt/wt) of nano oxide were prepared. Since for obtaining nanocomposites and irradiating polymers are promising tools and attractive for improving the material performance, the effects of nano-zinc oxide and gamma radiation, at doses ranged from 10 to 50 kGy, were evaluated in terms of thermal characteristics of the rPC. The rPC/nZnO nanocomposites were characterized by thermogravimetric analysis (TGA), differential exploratory calorimetry (DSC), infrared spectrometry (FT-IR) and wide angle X-ray diffraction (WAXD). There was a progressive decrease of the T_g as function of gamma dosage and nano-zinc oxide content. Initially, the T_o_n_s_e_t and T_m_a_x decayed as function of gamma dosage but a recovery was observed. The amount of nano-zinc oxide induced a decreasing of T_o_n_s_e_t and T_m_a_x. (author)

  18. Grafting of phosphorylcholine functional groups on polycarbonate urethane surface for resisting platelet adhesion

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Bin [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Feng, Yakai, E-mail: yakaifeng@hotmail.com [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Tianjin University-Helmholtz-Zentrum Geesthacht, Joint Laboratory for Biomaterials and Regenerative Medicine, Weijin Road 92, 300072 Tianjin (China); Key Laboratory of Systems Bioengineering, Ministry of Education, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Lu, Jian; Zhang, Li; Zhao, Miao; Shi, Changcan; Khan, Musammir [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Guo, Jintang [School of Chemical Engineering and Technology, Tianjin University, Weijin Road 92, Tianjin 300072 (China); Tianjin University-Helmholtz-Zentrum Geesthacht, Joint Laboratory for Biomaterials and Regenerative Medicine, Weijin Road 92, 300072 Tianjin (China)

    2013-07-01

    In order to improve the resistance of platelet adhesion on material surface, 2-methacryloyloxyethyl phosphorylcholine (MPC) was grafted onto polycarbonate urethane (PCU) surface via Michael reaction to create biomimetic structure. After introducing primary amine groups via coupling tris(2-aminoethyl)amine (TAEA) onto the polymer surface, the double bond of MPC reacted with the amino group to obtain MPC modified PCU. The modified surface was characterized by Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS). The results verified that MPC was grafted onto PCU surface by Michael reaction method. The MPC grafted PCU surface had a low water contact angle and a high water uptake. This means that the hydrophilic PC functional groups improved the surface hydrophilicity significantly. In addition, surface morphology of MPC grafted PCU film was imaged by atomic force microscope (AFM). The results showed that the grafted surface was rougher than the blank PCU surface. In addition, platelet adhesion study was evaluated by scanning electron microscopy (SEM) observation. The PCU films after treated with platelet-rich plasma demonstrated that much fewer platelets adhered to the MPC-grafted PCU surface than to the blank PCU surface. The antithrombogenicity of the MPC-grafted PCU surface was determined by the activated partial thromboplastin time (APTT). The result suggested that the MPC modified PCU may have potential application as biomaterials in blood-contacting and some subcutaneously implanted devices. - Highlights: • MPC was successfully grafted onto polycarbonate urethane surface via Michael reaction. • High concentration of PC functional groups on the surface via TAEA molecule • Biomimetic surface modification • The modified surface showed high hydrophilicity and anti-platelet adhesion.

  19. Microscopic hydrodynamics study with nuclear track membrane

    International Nuclear Information System (INIS)

    Shilun Guo; Yuhua Zhao; Yulan Wang; Hiuhong Hao; Brandt, R.; Vater, P.

    1988-01-01

    Microscopic hydrodynamics has been studied using different liquids and nuclear track membranes with pores perpendicularly piercing through them. The flow rate of water and alcohol has been studied with polycarbonate track membranes with pore diameters 1.48 micrometres and 1.08 micrometres. It has been shown that the flow rate both for water and alcohol on a microscopic scale can be determined by the Poiseuille law which characterizes macroscopic laminar flow. The Reynolds number used in macroscopic fluid flow has been calculated from the flow rate and parameters of the liquids and the geometry of the pores. It has been shown that this Reynolds number can also be used to characterize microscopic flow. Based on the above results, the filtration capacity (or limit) of polycarbonate track microfilters for water had been calculated. Some possible limits on the application of the calculation are pointed out and discussed. (author)

  20. Precise small-angle X-ray scattering evaluation of the pore structures in track-etched membranes: Comparison with other convenient evaluation methods

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Tsukasa, E-mail: t_miyazaki@cross.or.jp [Neutron Science and Technology Center, Comprehensive Research Organization for Science and Society, 162-1, Shirakata, Tokai-mura, Naka-gun, Ibaraki 319-1106 (Japan); Takenaka, Mikihito [Department of Polymer Chemistry, Gradual School of Engineering, Kyoto University, Kyotodaigaku-katsura, Kyoto 615-8510 (Japan)

    2017-03-01

    Poly(ethylene terephthalate) (PET)-based track-etched membranes (TMs) with pore sizes ranging from few nanometers to approximately 1 μm are used in various applications in the biological field, and their pore structures are determined by small-angle X-ray scattering (SAXS). These TMs with the nanometer-sized cylindrical pores aligned parallel to the film thickness direction are produced by chemical etching of the track in the PET films irradiated by heavy ions with the sodium hydroxide aqueous solution. It is well known that SAXS allows us to precisely and statistically estimate the pore size and the pore size distribution in the TMs by using the form factor of a cylinder with the extremely long pore length relative to the pore diameter. The results obtained were compared with those estimated with scanning electron microscopy and gas permeability measurements. The result showed that the gas permeability measurement is convenient to evaluate the pore size of TMs within a wide length scale, and the SEM observation is also suited to estimate the pore size, although SEM observation is usually limited above approximately 30 nm.

  1. Polycarbonate surface cell's adhesion examination after Nd:YAG laser irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ramazani, S.A. Ahmad, E-mail: Ramazani@sharif.ir [Polymer Group, Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Mousavi, Seyyed Abbas, E-mail: Musavi@che.sharif.ir [Department of Chemistry, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Seyedjafari, Ehsan [Department of Biotechnology, University College of Science, University of Tehran (Iran, Islamic Republic of); Poursalehi, Reza [Department of Physics, University of Shahed, Tehran (Iran, Islamic Republic of); Sareh, Shohreh [Research Center of Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of); Silakhori, Kaveh [Laser Research Center, Atomic Energy Organization, Tehran (Iran, Islamic Republic of); Poorfatollah, Ali Akbar [Research Center of Iranian Blood Transfusion Organization, Tehran (Iran, Islamic Republic of); Shamkhali, Amir Nasser [Department of Chemistry, Sharif University of Technology, Tehran (Iran, Islamic Republic of)

    2009-05-05

    Nd:YAG laser treatment was used in order to increase surface cell adhesion aspects of polycarbonate (PC) films prepared via melt process. The treatment was carried out under different wavelengths and beam diameters. ATR-FTIR and UV spectra obtained from different samples before and after laser treatment in air showed that laser irradiation has induced some chemical and physical changes in surface properties. The irradiated films were also characterized using scanning electron microscopy (SEM) and contact angle measurements. Effect of pulse numbers on the surface properties was also investigated. Cell culture test was used to evaluate cell adhesion property on the PC films before and after treatment. The results obtained from this test showed that after laser treatment, the cells were attached and proliferated extensively on the Nd:YAG laser treated films in comparison with the unmodified PC. Moreover, it was revealed that a decrease in the laser beam diameter and an increase in the irradiated pulse numbers increased surface wettability and caused a better cell attachment on the polymer surface. The obtained results also showed that a decrease in the laser beam diameter and an increase in the irradiated pulse numbers increased surface wettability and caused a better cell attachment on the polymer surface.

  2. Enhancing hydrophilicity and water permeability of PET track-etched membranes by advanced oxidation process

    International Nuclear Information System (INIS)

    Korolkov, Ilya V.; Mashentseva, Anastassiya A.; Güven, Olgun; Zdorovets, Maxim V.; Taltenov, Abzal A.

    2015-01-01

    In this study we present results on the application of advanced oxidation systems for effective and non-toxic oxidation of poly(ethylene terephthalate) track-etched membranes (PET TeMs) to improve their wettability and water transport properties. Two oxidizing systems: H 2 O 2 under UV irradiation (H 2 O 2 /UV) and Fenton system under visible light (Fenton/H 2 O 2 /Vis) were compared. The surface of functionalized PET TeMs was characterized by using colorimetric assay, contact angle measurements and X-ray photoelectron spectroscopy (XPS). Results clearly showed that water permeability of PET TeMs treated with H 2 O 2 /UV was improved by 28 ± 5% compared with etched-only membrane, the same parameter was found to increase by 13 ± 4% in the case of Fenton/H 2 O 2 /Vis treatment. The proposed oxidation technique is very simple, environment friendly and not requiring special equipment or expensive chemicals. The surface hydrophilicity of the membranes stored for 360 days in air between paper sheets was analyzed by contact angle test, colorimetric assay to measure concentration of carboxylic groups on the surface with toluidine blue and XPS analysis. The hydrophilic properties of oxidized PET TeMs were found to be stable for a long period of time.

  3. Enhancing hydrophilicity and water permeability of PET track-etched membranes by advanced oxidation process

    Science.gov (United States)

    Korolkov, Ilya V.; Mashentseva, Anastassiya A.; Güven, Olgun; Zdorovets, Maxim V.; Taltenov, Abzal A.

    2015-12-01

    In this study we present results on the application of advanced oxidation systems for effective and non-toxic oxidation of poly(ethylene terephthalate) track-etched membranes (PET TeMs) to improve their wettability and water transport properties. Two oxidizing systems: H2O2 under UV irradiation (H2O2/UV) and Fenton system under visible light (Fenton/H2O2/Vis) were compared. The surface of functionalized PET TeMs was characterized by using colorimetric assay, contact angle measurements and X-ray photoelectron spectroscopy (XPS). Results clearly showed that water permeability of PET TeMs treated with H2O2/UV was improved by 28 ± 5% compared with etched-only membrane, the same parameter was found to increase by 13 ± 4% in the case of Fenton/H2O2/Vis treatment. The proposed oxidation technique is very simple, environment friendly and not requiring special equipment or expensive chemicals. The surface hydrophilicity of the membranes stored for 360 days in air between paper sheets was analyzed by contact angle test, colorimetric assay to measure concentration of carboxylic groups on the surface with toluidine blue and XPS analysis. The hydrophilic properties of oxidized PET TeMs were found to be stable for a long period of time.

  4. An improved technique for fission track dating

    International Nuclear Information System (INIS)

    Zhao Yunlong; Wu Zhaohui; Xia Yuliang

    1996-01-01

    The necessity of improving the fission track dating (FTD) technique both at home and abroad is illustrated. The ways of making such improvement are also proposed. It is suggested to calibrate the constant b value of the uranium standard glass by using the method of fission products activity. The 3 kinds of uranium standard glass which have been calibrated are NBS SRM962a, UB 1 and UB 2 . An established new method σ·Φ ρ d /b, to measure neutron fluence, avoids the influence of the varying neutron spectrum on measuring neutron fluence. The improved etching technique for fission tracks in zircon adopted a two-step method which includes the molten alkali system etching using NaOH + KOH and the mixed acid system etching using HNO 3 + HF; this technique results in adequate track etching, increased track clarity and less interference. In this way the intensity of tracks is authentically reflected. Dividing angular zone in accordance with the angular distribution of spontaneous fission track on the crystal surface of minerals to count the tracks and using the improved etching technique to remove the non-uniform angular distribution of spontaneous fission tracks in zircon, ensure the accuracy of tracks count. The improved FTD techniques were used to finish Laboratory Standardized Calibration. The tests using international FTD age standards samples have proved that above mentioned techniques are reliable and practical in obtaining the accurate FTD data. (8 tabs.; 3 figs.)

  5. Comparison of neutron dose measured by Albedo TLD and etched tracks detector at PNC plutonium fuel facilities

    International Nuclear Information System (INIS)

    Tsujimura, N.; Momose, T.; Shinohara, K.; Ishiguro, H.

    1996-01-01

    Power Reactor and Nuclear Fuel Development Corporation (PNC) has fabricated Plutonium and Uranium Mixed OXide (MOX) fuel for FBR MONJU at Tokai works. In this site, PNC/Panasonic albedo TLDs/1/ are used for personnel neutron monitoring. And a part of workers wore Etched Tracks Detector (ETD) combined with TLD in order to check the accuracy of the neutron dose estimated by albedo TLD. In this paper, the neutron dose measured by TLD and ETD in the routine monitoring is compared at PNC plutonium fuel facilities. (author)

  6. Coupled chemical reactions in dynamic nanometric confinement: V. The influence of Li+ and F- ions on etching of nuclear tracks in polymers

    Czech Academy of Sciences Publication Activity Database

    Fink, Dietmar; Hernandez, G. M.; Ruiz, N. L.; Vacík, Jiří; Hnatowicz, Vladimír; Garcia-Arellano, H.; Alfonta, L.; Kiv, A.

    2014-01-01

    Roč. 169, č. 5 (2014), s. 396-417 ISSN 1042-0150 R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : tracks * biotechnology * nanostruct * ions * etching Subject RIV: BO - Biophysics Impact factor: 0.513, year: 2014

  7. Effects of gamma radiation on country made polycarbonate Durolon FN2200

    International Nuclear Information System (INIS)

    Terence, Mauro Cesar

    1996-01-01

    Type II polycarbonate, PC II, manufactured with high purity reagents as used on medical fabrication was gamma irradiated by 60 Co source with doses from 0 to 300 kGy. Dose effects on the tensile strength at break (TSb) and at yield (TSy), on the molecular weight by viscosity, on optical properties by yellowness index (YI) and transmittance (T), molecular structure by transmission spectroscopy on infrared region (IR). Radical formation and decay at 100 kGy was studied too by electronic paramagnetic resonance (EPR) and nuclear magnetic resonance of proton (NMR 1 H). T S alteration was not observed up to 100 kGy, but molecular weight already suffers alteration at low doses, as well optical properties suffer significant alteration at sterilization doses (25 kGy) by yellowness index of 90% that is not desirable by medical application point of view. Molecular scission degree was calculated from viscosity measurements which value found is 1 and the crosslinking was not observed at sterilization doses. The formation of three different radicals was observed phenoxy, phenyl and isopropyl when irradiated on vacuum and after being put in air contact, scission occurs on PC II on two sites of the polymeric chain, while on PC I scission occurs only in one site. The PC II can be used in sterilized medical devices by gamma radiation from R T point of view, but looking to optical properties in a incorporation of additives will be necessary to cover up this coloration, as an optical whitener. It is interesting to note although PC II has G scission = 1 and yellowness index of 17% and P C I has G scission = 16,7 and yellowness index of 27% this difference can be attributed to the large quantity of optical whitener added to PC I. At sterilization doses PC II has an excellent radiolytic stability considering the point of view TS but it is necessary to avoid the yellowness on the fabrication of medical devices that can be radio sterilized. (author)

  8. Determination of the depth of an etch pit through studies of diffraction rings

    Energy Technology Data Exchange (ETDEWEB)

    Basu, B. [Department of Physics, Bose Institute, 93/1 APC Road, Kolkata 700 009 (India); Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India); Dey, S.; Maulik, A. [Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India); Raha, Sibaji [Department of Physics, Bose Institute, 93/1 APC Road, Kolkata 700 009 (India); Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India); Saha, S. [Nuclear and Atomic Physics Division, Saha Institute of Nuclear Physics, Kolkata 700 064 (India); Saha, Swapan K. [Department of Physics, Bose Institute, 93/1 APC Road, Kolkata 700 009 (India); Centre for Astroparticle Physics and Space Science, Bose institute, Kolkata 700 091 (India)], E-mail: swapan@bosemain.boseinst.ac.in; Syam, D. [Department of Physics, Presidency College, Kolkata 700 073 (India)

    2009-04-15

    A Solid State Nuclear Track Detector (SSNTD) can be used to identify an impinging ion as well as to determine the energy of that ion. The track of the ion is made visible by chemically 'etching' the detector after exposure. By finding out the ratio of the track-etch rate (V{sub t}) to the bulk-etch rate (V{sub g}), together with the range of the ion in the detector, the identity and the energy of the ion can be ascertained. The required measurements can be conveniently made with the help of a microscope when the angle of incidence of the ion, with respect to the normal direction to the detector surface, is more than 15 deg.. For normal or near normal incidence, uncertainties plague the measurement of the depth of the etch pit and hence the range of the particle. Through this article we wish to suggest an alternative method of assessment, based on the observation of diffraction rings, of the depth of an etch pit.

  9. Coupled chemical reactions in dynamic nanometric confinement: IV. Ion transmission spectrometric analysis of nanofluidic behavior and membrane formation during track etching in polymers

    Czech Academy of Sciences Publication Activity Database

    Fink, Dietmar; Vacík, Jiří; Hnatowicz, Vladimír; Munoz, G. H.; Arellano, H. G.; Kiv, A.; Alfonta, L.

    2015-01-01

    Roč. 170, č. 3 (2015), s. 155-174 ISSN 1042-0150 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:61389005 Keywords : ions * etching * tracks Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.472, year: 2015

  10. Etched ion tracks in silicon oxide and silicon oxynitride as charge injection or extraction channels for novel electronic structures

    International Nuclear Information System (INIS)

    Fink, D.; Petrov, A.V.; Hoppe, K.; Fahrner, W.R.; Papaleo, R.M.; Berdinsky, A.S.; Chandra, A.; Chemseddine, A.; Zrineh, A.; Biswas, A.; Faupel, F.; Chadderton, L.T.

    2004-01-01

    The impact of swift heavy ions onto silicon oxide and silicon oxynitride on silicon creates etchable tracks in these insulators. After their etching and filling-up with highly resistive matter, these nanometric pores can be used as charge extraction or injection paths towards the conducting channel in the underlying silicon. In this way, a novel family of electronic structures has been realized. The basic characteristics of these 'TEMPOS' (=tunable electronic material with pores in oxide on silicon) structures are summarized. Their functionality is determined by the type of insulator, the etch track diameters and lengths, their areal densities, the type of conducting matter embedded therein, and of course by the underlying semiconductor and the contact geometry. Depending on the TEMPOS preparation recipe and working point, the structures may resemble gatable resistors, condensors, diodes, transistors, photocells, or sensors, and they are therefore rather universally applicable in electronics. TEMPOS structures are often sensitive to temperature, light, humidity and organic gases. Also light-emitting TEMPOS structures have been produced. About 37 TEMPOS-based circuits such as thermosensors, photosensors, humidity and alcohol sensors, amplifiers, frequency multipliers, amplitude modulators, oscillators, flip-flops and many others have already been designed and successfully tested. Sometimes TEMPOS-based circuits are more compact than conventional electronics

  11. Mapping of uranium and thorium in radioactive rocks using nuclear track solid detectors

    International Nuclear Information System (INIS)

    Bouch, C.M.

    1982-01-01

    α-Autoradiography and studies of induced fission in a research nuclear reactor (IEA-R1, IPEN, Sao Paulo) were done, employing Solid-State Nuclear Track detectors, in order to study the distribution of α-emitters, U and Th in rocks. Polished sections of rocks were prepared and photographed. Etching conditions were studied in order to adapt the detectors to the studies of microdistribution and macrodistribution of tracks. Polycarbonate foils (Bayer, Makrofol) were chosen as fission-fragments detectors and the technique of fission induced with reactor neutrons to obtain the distribution of U and Th were studied. Uranium and thorium standards evaporated on the surface of the detectors, as well as thorite and uraninite grains, were irradiated in order to measure the integrated flux of neutrons, the effective cross sections for fission with reactor neutrons for 232 Th(0,05b) and 238 U(0,30b) and to study the contribution of 238 U fission in thorium mapping. A technique for determination of uranium and thorium in minerals was studied and applied to Mica, for which were determined the contents of 4,2 ppb U e 58 ppb Th. (Author) [pt

  12. Direct determination of bulk etching rate for LR-115-II solid state ...

    Indian Academy of Sciences (India)

    The thickness of the removed layer of the LR-115-II solid state nuclear track detector during etching is measured directly with a rather precise instrument. Dependence of bulk etching rate on temperature of the etching solution is investigated. It has been found that the bulk etching rate is 3.2 m/h at 60°C in 2.5 N NaOH of ...

  13. Effects of gamma irradiation on optical properties of polycarbonate: different formulations with commercial stabilizers

    International Nuclear Information System (INIS)

    Ferreira, Carlas C.; Aquino, Katia Aparecida da S.; Araujo, Elmo S.

    2009-01-01

    Medical plastics are in general sterilized by gamma irradiation in doses of 25 kGy. However, this process often causes discoloration of the product due the formation of color centers during the irradiation. In particular, polycarbonate (PC), a transparent thermoplastic, when gamma-irradiated undergoes main chain scissions with consequent yellowness. This discoloration is attributed the formation of macroradicals type phenoxyl and phenyl produced by irradiation process. PC was prepared in formulations containing different stabilizers in order to investigate its optical properties (transmittance and yellowness index) changed by irradiation process. Among the stabilizers tested, a new commercial stabilizer (high performance phosphite) has presented good results concerning to reduction of the yellowness in irradiated specimen tests. Transmittance (at 420 nm) of irradiated samples at doses of 25 kGy decreases to ∼ 45% of non-irradiated sample value, immediately to the irradiation process. Nevertheless, this transmittance is increased to values of ∼ 70% of non-irradiated sample, after 60 hours under heating into oven (45 deg C). (author)

  14. Study of the pore-opening process of latent tracks of light low-energetic ions in CR-39 by means of electrolytic etching

    International Nuclear Information System (INIS)

    Oganesyan, V.R.

    2005-01-01

    In this thesis the irradiation of 10-μm thick CR-39 foils with 5.5-7 MeV protons and of 22-400 μm thick CR-39 foils with 4.85-28 MeV α-particles with subsequent determination of the etching velocities is described. By means of scanning electron microscopy (SEM) the pore shape after irradiation was determined. From the analysis of the track profiles by means of SEM the track-nucleus diameter for 28 MeV α particles was determined to 1.4 nm. (HSI)

  15. Fission tracks diameters in glasses

    International Nuclear Information System (INIS)

    Garzon Ruiperez, L.; Veiguela, J.

    1974-01-01

    Standard glass microscope slides have been irradiated with fission fragments from the uranium. The etching track conditions have been the same for the series, having changed the etching time only for each specimen. For each glass, a minimum of 250 measurements of the tracks diameters have been made, the distributions of which are the bimodal type. Diameters-etching dependence with time is roughly lineal. Energy determinations have been made with the help of the diameters-energy relations. The calculated values agree very well with the know ones. (author) [es

  16. Electrostatic force microscopy and electrical isolation of etched few-layer graphene nano-domains

    Energy Technology Data Exchange (ETDEWEB)

    Hunley, D. Patrick; Sundararajan, Abhishek; Boland, Mathias J.; Strachan, Douglas R., E-mail: doug.strachan@uky.edu [Department of Physics and Astronomy, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2014-12-15

    Nanostructured bi-layer graphene samples formed through catalytic etching are investigated with electrostatic force microscopy. The measurements and supporting computations show a variation in the microscopy signal for different nano-domains that are indicative of changes in capacitive coupling related to their small sizes. Abrupt capacitance variations detected across etch tracks indicates that the nano-domains have strong electrical isolation between them. Comparison of the measurements to a resistor-capacitor model indicates that the resistance between two bi-layer graphene regions separated by an approximately 10 nm wide etch track is greater than about 1×10{sup 12} Ω with a corresponding gap resistivity greater than about 3×10{sup 14} Ω⋅nm. This extremely large gap resistivity suggests that catalytic etch tracks within few-layer graphene samples are sufficient for providing electrical isolation between separate nano-domains that could permit their use in constructing atomically thin nanogap electrodes, interconnects, and nanoribbons.

  17. Electrostatic force microscopy and electrical isolation of etched few-layer graphene nano-domains

    International Nuclear Information System (INIS)

    Hunley, D. Patrick; Sundararajan, Abhishek; Boland, Mathias J.; Strachan, Douglas R.

    2014-01-01

    Nanostructured bi-layer graphene samples formed through catalytic etching are investigated with electrostatic force microscopy. The measurements and supporting computations show a variation in the microscopy signal for different nano-domains that are indicative of changes in capacitive coupling related to their small sizes. Abrupt capacitance variations detected across etch tracks indicates that the nano-domains have strong electrical isolation between them. Comparison of the measurements to a resistor-capacitor model indicates that the resistance between two bi-layer graphene regions separated by an approximately 10 nm wide etch track is greater than about 1×10 12  Ω with a corresponding gap resistivity greater than about 3×10 14  Ω⋅nm. This extremely large gap resistivity suggests that catalytic etch tracks within few-layer graphene samples are sufficient for providing electrical isolation between separate nano-domains that could permit their use in constructing atomically thin nanogap electrodes, interconnects, and nanoribbons

  18. Frictional and Optical Properties of Diamond-Like-Carbon Coatings on Polycarbonate

    International Nuclear Information System (INIS)

    Lin Zeng; Gao Ding; Ba Dechun; Wang Feng; Liu Chunming

    2013-01-01

    In this work, diamond-like-carbon (DLC) films were deposited onto polycarbonate (PC) substrates by radio-frequency plasma-enhanced chemical vapor deposition (RF PECVD), and silicon films were prepared between DLC and PC substrates by magnetron sputtering deposition so as to improve the adhesion of the DLC films. The deposited films were investigated by means of field-emission scanning electron microscopy (FE-SEM), X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy. Subsequently, the following frictional and optical properties of the films were measured: the friction coefficient by using a ball-on-disk tribometer, the scratch hardness by using a nano-indenter, the optical transmittance by using a UV/visible spectrometer. The effects of incident power upon the frictional and optical properties of the films were investigated. Films deposited at low incident powers showed large optical gaps, which decreased with increasing incident power. The optical properties of DLC films correlated to the sp 2 content of the coatings. High anti-scratch properties were obtained at higher values of incident power. The anti-scratch properties of DLC films correlated to the sp 3 content of the coatings

  19. Enhancing hydrophilicity and water permeability of PET track-etched membranes by advanced oxidation process

    Energy Technology Data Exchange (ETDEWEB)

    Korolkov, Ilya V.; Mashentseva, Anastassiya A. [Institute of Nuclear Physics, Ibrahimov Str., 1, 050032 Almaty (Kazakhstan); The L.N. Gumilyov Eurasian National University, Satpaev Str., 5, 010008 Astana (Kazakhstan); Güven, Olgun [Department of Chemistry, Hacettepe University, 06800 Beytepe, Ankara (Turkey); Zdorovets, Maxim V. [Institute of Nuclear Physics, Ibrahimov Str., 1, 050032 Almaty (Kazakhstan); The L.N. Gumilyov Eurasian National University, Satpaev Str., 5, 010008 Astana (Kazakhstan); Taltenov, Abzal A. [The L.N. Gumilyov Eurasian National University, Satpaev Str., 5, 010008 Astana (Kazakhstan)

    2015-12-15

    In this study we present results on the application of advanced oxidation systems for effective and non-toxic oxidation of poly(ethylene terephthalate) track-etched membranes (PET TeMs) to improve their wettability and water transport properties. Two oxidizing systems: H{sub 2}O{sub 2} under UV irradiation (H{sub 2}O{sub 2}/UV) and Fenton system under visible light (Fenton/H{sub 2}O{sub 2}/Vis) were compared. The surface of functionalized PET TeMs was characterized by using colorimetric assay, contact angle measurements and X-ray photoelectron spectroscopy (XPS). Results clearly showed that water permeability of PET TeMs treated with H{sub 2}O{sub 2}/UV was improved by 28 ± 5% compared with etched-only membrane, the same parameter was found to increase by 13 ± 4% in the case of Fenton/H{sub 2}O{sub 2}/Vis treatment. The proposed oxidation technique is very simple, environment friendly and not requiring special equipment or expensive chemicals. The surface hydrophilicity of the membranes stored for 360 days in air between paper sheets was analyzed by contact angle test, colorimetric assay to measure concentration of carboxylic groups on the surface with toluidine blue and XPS analysis. The hydrophilic properties of oxidized PET TeMs were found to be stable for a long period of time.

  20. Region-selective electroless gold plating on polycarbonate sheets by UV-patterning in combination with silver activating

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Qinghua [Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Zijin' gang Campus, Hangzhou 310058 (China); Chen Hengwu, E-mail: hwchen@zju.edu.c [Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Zijin' gang Campus, Hangzhou 310058 (China); Wang Yi [Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Zijin' gang Campus, Hangzhou 310058 (China)

    2010-02-28

    A simple, time- and cost-effective approach for region-selective metalization of polycarbonate (PC) surface has been established by combining photoresist-free UV-patterning with tin- and amine-free silver activating and electroless gold plating. The surface of PC sheets was exposed to the UV lights emitted from a low-pressure mercury lamp through a photomask, the micro pattern on the mask being transferred to the PC surface due to the photochemical generation of carboxyl groups on the UV-exposed region. The UV-exposed PC sheets were then treated with an ammoniacal AgNO{sub 3} solution, so that the silver ions were chemisorbed by the photochemically generated carboxyl groups. When the Ag{sup +}-adsorbed PC sheet was immersed into an electroless gold plating bath, shiny gold film quickly deposited on the UV-exposed region, resulting in the formation of a micro gold devices on the PC surface. The whole plating process including UV-exposure, surface activating and gold plating can be completed in about 3-4 h. Attenuated total reflection Fourier transformation infrared spectrometer (ATR-FT-IR), X-ray photoelectron spectroscopy (XPS), atomic force microscope (AFM) and scanning electron microscope (SEM) were employed to trace the surface change during the plating process. Cyclic voltammetry (CV) and Scotch-tape test were employed to characterize the electrochemical properties and adhesion strength of the prepared micro gold devices, respectively. The prepared micro gold electrodes were demonstrated for amperometric detection of hydrogen peroxide.

  1. Comparison and limitations of three different bulk etch rate measurement methods used for gamma irradiated PM-355 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Fazal-ur-Rehman E-mail: fazalr@kfupm.edu.sa; Abu-Jarad, F.; Al-Jarallah, M.I.; Farhat, M

    2001-06-01

    Samples of Nuclear Track Detectors (PM-355) were exposed to high gamma doses from 1x10{sup 5} Gy (10 Mrad) up to 1.2x10{sup 6} Gy (120 Mrad) at an incremental dose of 1x10{sup 5} Gy (10 Mrad). The gamma source was a 9.03 PBq (244 kCi) Co-60 source used for sterilization of medical syringes. The bulk etch rate (V{sub b}) was measured for various high gamma doses by three different methods: 1--thickness change method; 2--mass change method; 3--fission track diametric method. The study gives a comparison and limitations of these three methods used for bulk etch rate measurements in the detectors as a function of high gamma doses. The track etch rate (V{sub t}) and the sensitivity (V) of the detector were also measured using the fission track diametric method. It was observed that V{sub b} increases with the increase of the gamma absorbed dose at a fixed etching time in each bulk etch measuring method. The bulk etch rate decreases exponentially with the etching time at a fixed gamma absorbed dose in all three methods. The thickness change and mass change methods have successfully been applied to measure V{sub b} at higher gamma doses up to 1.2x10{sup 6} Gy (120 Mrad). The bulk etch rate determined by the mass change and thickness change methods was almost the same at a certain gamma dose and etching time whereas it was quite low in the case of the fission track diametric method due to its limitations at higher doses. Also in this method it was not possible to measure the fission fragment track diameters at higher doses due to the quick disappearance of the fission tracks and therefore the V{sub b} could not be estimated at higher gamma doses.

  2. Reactive electrospinning and biodegradation of cross-linked methacrylated polycarbonate nanofibers

    Energy Technology Data Exchange (ETDEWEB)

    Wu Ruizhi; Zhang Jianfeng; Fan Yuwei; Xu Xiaoming [Department of Comprehensive Dentistry and Biomaterials, Louisiana State University Health Sciences Center, 1100 Florida Avenue, Box 137, New Orleans, LA 70119 (United States); Stoute, Diana; Lallier, Thomas, E-mail: xxu@lsuhsc.edu [Department of Cell Biology and Anatomy, Louisiana State University Health Science Center, 1100 Florida Avenue, Box 137, New Orleans, LA 70119 (United States)

    2011-06-15

    The objectives of this study were to fabricate cross-linked biodegradable polycarbonate nanofibers and to investigate their biodegradability by different enzymes. Poly(2,3-dihydroxycarbonate) was synthesized from naturally occurring l-tartaric acid. The hydroxyl groups on the functional polycarbonate were converted to methacrylate groups to enable the polymer to cross-link under UV irradiation. Smooth cross-linked methacrylated polycarbonate nanofibers (300-1800 nm) were fabricated by a reactive electrospinning process with in situ UV radiation from a mixed solution of linear methacrylated polycarbonate (MPC) and poly(ethylene oxide) (PEO) (MPC:PEO = 9:1) in methanol/chloroform (50/50). These cross-linked nanofibers have shown excellent solvent resistance and their solubility decreases with increasing degree of cross-linking. The thermal properties of linear and cross-linked polycarbonate nanofibers were investigated by differential scanning calorimetry and thermogravimetric analysis. The cross-linked polycarbonate nanofibers show no melting point below 200 {sup 0}C and their decomposition temperature increases with increasing cross-linking degree. Their biodegradation products by five different enzymes were analyzed using liquid chromatography-mass spectrometry (LC-MS). The biodegradability of the polycarbonate nanofibers decreases with increasing cross-linking degree. These nanofibers were found to support human fibroblast survival and to promote cell attachment. This study demonstrates that cross-linked biodegradable polycarbonate nanofibers with different chemical properties and biodegradability can be fabricated using the novel reactive electrospinning technology to meet the needs of different biomedical applications.

  3. THE AQUATIC-POLYCARBONATE SKYLIGHT FOR SURABAYA INDONESIA

    Directory of Open Access Journals (Sweden)

    Danny Santoso Mintorogo

    2007-01-01

    Full Text Available This paper will indicate of how appropriate use of aquatic skylight module installed on buildings in the tropical zone compared to the ones in the subtropical climate. In order for energy saving strategies, the aquatic-polycarbonate skylight system is used in the tropical climate. In the tropical hot humid climate, Indonesia has received huge amount of global direct and diffuse radiations on horizontal roofs throughout the year, approximately 525 watts per square meter of solar radiation will impact on flat roofs or skylights on a clear sunny day in Surabaya city. Ironically, most of the commercial and institution buildings are equipped with Western skylight styles in Surabaya without any modifications. The aquatic-polycarbonate skylight is the system that will control daylight, scatter direct solar heat radiation, cool the indoor polycarbonate surface temperature, and collect solar hot water at the same time. The concept of using the water as shading device has three goals: first of all, the flushing water in the polycarbonate holes tries to scatter horizontal or tiled skylight direct sun-ray radiation, and minimize the direct sun heat temperature on the polycarbonate with flushing water continuously. Secondly, the sparkle flushing water in series of square holes of polycarbonate will bounce and disperse the direct sunlight into the space below enhancing daylight patterns. Finally, while bouncing, sparkling and scattering direct sunlight, those series of flushing water holes would also collect the solar heat radiation as solar hot water. Each system could works nicely to absorb, to scatter, to minimize, and to obtain the solar heat radiation for solar hot water in buildings. This strategy aims to provide a clean environment living zones with applying passive heating and cooling systems.

  4. A bezel of an automotive headlamp: scrap/virgin ratio effects on its physicochemical properties due to the use of recycled polycarbonate

    OpenAIRE

    Vega, Etzail; González-Calderón, J. A.; Villegas, Antonio; Montiel, Raúl; Pérez, Elías; Vallejo-Montesinos, Javier

    2016-01-01

    Abstract: Automotive bezels of polycarbonate (PC) were prepared in this work by varying the amount of recycled polymer in order to estimate an acceptable scrap/virgin ratio that maintains the material properties. Conducted tests allow us to define the limit to don't compromise the performance of recycled pieces. The studied properties were their chemical structure, molecular weight distribution, mechanical and surface properties of the samples. Results showed no change in the chemical structu...

  5. Track-etch membranes enabled nano-/microtechnology: A review

    International Nuclear Information System (INIS)

    Chakarvarti, S.K.

    2009-01-01

    The art and science of fabricating structures with nano-/micrometric dimensions as well as precision is of the immense concern to any one investigating into nano-/microtechnology. The synergetic support of radiation and its potential in combining radiation effects with nano-/micromaterials has been recognized from the very early stages of nano-science research. In the myriad of applications and uses of nano-/microstructures, and nano particles in particular, from filtration, fabrication of biosensors, a chemical catalysis, magnetic structures, nano-electronics, MEMS, mechano-chemical conversion, quantum computing etc to name a few, radiation can play a significant role. One such potential application is track-etch membranes- a spin-off from the matter-radiation interaction. In the recent years, there has been a tremendous leap in the potential applications of metallic as well as non-metallic nano-/microstructures and materials. Nanotechnology has initiated a big hop and appears to be all set for bringing in revolution in the development and advancement of techniques involved in the synthesis and fabrication of sensors and devices. The conventional techniques for fabrication of very low dimensional wires - say quantum wires, include wet chemistry, electron beam lithography, focused ion beam techniques and atomic-beam lithography but for certain drawbacks and problems mentioned further. That has shown the ways for adopting newer alternative approaches which are relatively inexpensive, easier to handle and synergistically adorned with high efficacy. It is now well known that size of the devices and components dictate many unusual traits where quantum effects become more predominant. Quasi-one-dimensional nanostructures and materials like nanowires, fibres, tubules etc, having high aspect ratio would provide unusual and uncommon properties. Some properties like strength and hardness enhancement, dramatic changes in electrical conduction, field-ion-emission through

  6. Track-etch membranes enabled nano-/microtechnology: A review

    Energy Technology Data Exchange (ETDEWEB)

    Chakarvarti, S.K., E-mail: skchakarvarti@gmail.co [Department of Physics, National Institute of Technology, Institution of National Importance, Kurukshetra 136 119 (India)

    2009-10-15

    The art and science of fabricating structures with nano-/micrometric dimensions as well as precision is of the immense concern to any one investigating into nano-/microtechnology. The synergetic support of radiation and its potential in combining radiation effects with nano-/micromaterials has been recognized from the very early stages of nano-science research. In the myriad of applications and uses of nano-/microstructures, and nano particles in particular, from filtration, fabrication of biosensors, a chemical catalysis, magnetic structures, nano-electronics, MEMS, mechano-chemical conversion, quantum computing etc to name a few, radiation can play a significant role. One such potential application is track-etch membranes- a spin-off from the matter-radiation interaction. In the recent years, there has been a tremendous leap in the potential applications of metallic as well as non-metallic nano-/microstructures and materials. Nanotechnology has initiated a big hop and appears to be all set for bringing in revolution in the development and advancement of techniques involved in the synthesis and fabrication of sensors and devices. The conventional techniques for fabrication of very low dimensional wires - say quantum wires, include wet chemistry, electron beam lithography, focused ion beam techniques and atomic-beam lithography but for certain drawbacks and problems mentioned further. That has shown the ways for adopting newer alternative approaches which are relatively inexpensive, easier to handle and synergistically adorned with high efficacy. It is now well known that size of the devices and components dictate many unusual traits where quantum effects become more predominant. Quasi-one-dimensional nanostructures and materials like nanowires, fibres, tubules etc, having high aspect ratio would provide unusual and uncommon properties. Some properties like strength and hardness enhancement, dramatic changes in electrical conduction, field-ion-emission through

  7. Facile attachment of nonlinear optical chromophores to polycarbonates

    NARCIS (Netherlands)

    Faccini, M.; Balakrishnan, M.; Torosantucci, Riccardo; Driessen, A.; Reinhoudt, David; Verboom, Willem

    2008-01-01

    A versatile, generally applicable synthetic methodology for side-chain NLO polycarbonates was developed. This represents the first example of covalent incorporation of NLO chromophores to a prepolymerized polycarbonate backbone. This methodology allows to adjust the polymer backbone structure and to

  8. Dependence of yield of nuclear track-biosensors on track radius and analyte concentration

    Science.gov (United States)

    García-Arellano, H.; Muñoz H., G.; Fink, D.; Vacik, J.; Hnatowicz, V.; Alfonta, L.; Kiv, A.

    2018-04-01

    In swift heavy ion track-based polymeric biosensor foils with incorporated enzymes one exploits the correlation between the analyte concentration and the sensor current, via the enrichment of charged enzymatic reaction products in the track's confinement. Here we study the influence of the etched track radius on the biosensor's efficiency. These sensors are analyte-specific only if both the track radii and the analyte concentration exceed certain threshold values of ∼15 nm and ∼10-6 M (for glucose sensing), respectively. Below these limits the sensor signal stems un-specifically from any charge carrier. In its proper working regime, the inner track walls are smoothly covered by enzymes and the efficiency is practically radius independent. Theory shows that the measured current should be slightly sub-proportional to the analyte concentration; the measurements roughly reconfirm this. Narrower tracks (∼5-15 nm radius) with reduced enzyme coverage lead to decreasing efficiency. Tiny signals visible when the tracks are etched to effective radii between 0 and ∼5 nm are tentatively ascribed to enzymes bonded to surface-near nano-cracks in the polymer foil, resulting from its degradation due to aging, rather than to the tracks. Precondition for this study was the accurate determination of the etched track radii, which is possible only by a nanofluidic approach. This holds to some extent even for enzyme-covered tracks, though in this case most of the wall charges are compensated by enzyme bonding.

  9. Pyrolysis and catalytic pyrolysis as a recycling method of waste CDs originating from polycarbonate and HIPS

    Energy Technology Data Exchange (ETDEWEB)

    Antonakou, E.V. [Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Kalogiannis, K.G.; Stephanidis, S.D. [Chemical Process Engineering Research Institute, 57001 Thermi, Thessaloniki (Greece); Triantafyllidis, K.S. [Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece); Chemical Process Engineering Research Institute, 57001 Thermi, Thessaloniki (Greece); Lappas, A.A. [Chemical Process Engineering Research Institute, 57001 Thermi, Thessaloniki (Greece); Achilias, D.S., E-mail: axilias@chem.auth.gr [Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2014-12-15

    Highlights: • Thermal and catalytic pyrolysis is a powerful method for recycling of WEEEs. • Liquid products obtained from the pyrolysis of PC or HIPS found in waste CDs are very different. • Mainly phenols are obtained from pyrolysis PC based wastes while aromatics from HIPS. • Use of MgO catalyst increases the amount of phenols from CD recycling compared to ZSM-5. • Use of MgO or ZSM-5 catalysts reduces the amount of styrene recovered from HIPS. - Abstract: Pyrolysis appears to be a promising recycling process since it could convert the disposed polymers to hydrocarbon based fuels or various useful chemicals. In the current study, two model polymers found in WEEEs, namely polycarbonate (PC) and high impact polystyrene (HIPS) and their counterparts found in waste commercial Compact Discs (CDs) were pyrolysed in a bench scale reactor. Both, thermal pyrolysis and pyrolysis in the presence of two catalytic materials (basic MgO and acidic ZSM-5 zeolite) was performed for all four types of polymers. Results have shown significant recovery of the monomers and valuable chemicals (phenols in the case of PC and aromatic hydrocarbons in the case of HIPS), while catalysts seem to decrease the selectivity towards the monomers and enhance the selectivity towards other desirable compounds.

  10. Interpretation of Mason's equation in terms of measurable electrochemical-etching parameters governing the dielectric breakdown phenomenon

    International Nuclear Information System (INIS)

    Al-Najjar, S.A.R.; Durrani, S.A.

    1986-01-01

    A new interpretation of Mason's equation, as applicable to the electrochemical etching (ECE) of tracks in polymers, is presented in terms of physically meaningful track-etching parameters. The values of these parameters have been experimentally obtained by irradiating CR-39 foils with heavy ions ( 238 U and 129 Xe) and α-particles of various energies, and applying chemical pre-etching (CPE), followed by ECE in steps, with increasing electric field until the 'treeing' breakdown is initiated. A value of 1.19 MV cm -1 is obtained for the intrinsic electrical breakdown stress of CR-39. It is found that the track radius r used in Mason's equation is related to the radius rsub(Θ) of a sphere, inscribed within the etch cone, whose lowest point is at a fixed distance lsub(o) above the cone tip, with lsub(o) ≅ 1.75 μm for α-particle tracks of energies 2-5.5 MeV, such that r = 0.43 + rsub(Θ) (in μm). (author)

  11. The effect of ArF laser irradiation (193 nm) on the photodegradation and etching properties of alpha-irradiated CR-39 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Shakeri Jooybari, B. [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Nuclear Science and Technology Research Institute (NSRT), Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Ghergherehchi, M. [College of Information and Technology/ school of Electronic and Electrical Engineering, Sungkyunkwan University, Suwon (Korea, Republic of); Afarideh, H., E-mail: hafarideh@aut.ac.ir [Department of Energy Engineering and Physics, Amirkabir University of Technology, P.O. Box 15875-4413, Tehran, Islamic Republic of Iran (Iran, Islamic Republic of); Lamehi-Rachti, M. [Nuclear Science and Technology Research Institute (NSRT), Tehran, Islamic Republic of Iran (Iran, Islamic Republic of)

    2015-01-01

    The effects of ArF laser irradiation (λ=193nm) at various fluences (energy dose or energy density) on the etching properties of pre-exposed (laser + alpha) CR-39 detectors were studied. First, UV–Vis and Fourier transform infrared (FTIR) spectra were acquired for non-laser-irradiated and laser-irradiated samples to detect the influence of the ArF laser on the chemical modification of the CR-39. Changes observed in the spectra indicated that the predominant process that occurred upon ArF laser irradiation was a bond-scission process. Thereafter, the mean track and bulk etching parameters were experimentally measured in ArF-laser-irradiated CR-39 detectors exposed to an alpha source ({sup 241}Am, E = 5.49 MeV). Inhomogeneous regions in the laser-irradiated side of the CR-39 demonstrated a variable etching rate on only the front side of the CR-39 detector. New equations are also presented for the average bulk etching rate for these inhomogeneous regions (front side). The mean bulk and track etching rates and the mean track dimensions increased in a fluence range of 0–37.03 mJ/cm{sup 2} because of photodegradation and the scission of chemical bonds, which are the predominant processes in this range. When the fluence was increased from 37.03 to 123.45 mJ/cm{sup 2}, the bulk and track etching rates and the track dimensions slowly decreased because of the formation of cross-linked structures on the CR-39 surface. The behavior of the bulk and track etching rates and the track dimensions appears to be proportional to the dose absorbed on the detector surface. It was observed that as the etching time was increased, the bulk and track etching rates and the track dimensions of the laser-irradiated samples decreased because of the shallow penetration depth of the 193 nm laser and the reduction in the oxygen penetration depth.

  12. Background tracks in CR-39 SSNTD sheets: their control and prediction through an interplay of etching parameters

    International Nuclear Information System (INIS)

    Bhagwat, A.M.; Naik, G.R.; Thampan, S.; Rudran, K.; Joshi, V.B.; Iyer, M.R.

    1992-01-01

    High sensitivity of CR-39 film in turn leads to higher and variable background track-densities. A two-step etching process, each consisting of CE and ECE, is therefore suggested which permits not only partial freezing of the background but also allows to know its level. The procedure identifies bad pieces with scratches and determines the minimum detection limit (MDL) of each film individually. Activities as low as 0.2 mBq (∼ 5 x 10 -15 curies) can thus be measured with low background films for exposure periods of 7-10 days (exposure is carried out after first processing). (author)

  13. Observations of fission-tracks in zircons by atomic force microscope

    International Nuclear Information System (INIS)

    Ohishi, Shinnosuke; Hasebe, Noriko

    2012-01-01

    The fission-track (FT) method is a dating technique based on the observation of damage (tracks) by spontaneous fission of 238 U left in a mineral. The date is calculated from the track density and the uranium concentration in the mineral. This is possible because the number of tracks is a function of uranium concentration and time since the start of track accumulation. Usually, the number of tracks is counted under an optical microscope after etching (chemical expansion of a track). However, as FT density per unit area rises, it becomes difficult to count the number of tracks. This is due to the fact that FTs overlap one another and are unable to be readily distinguished. This research examines the potential of atomic force microscope (AFM) for FT dating using zircons, which are likely to show higher FT density than other minerals due to their high U concentrations. To obtain an AFM image for a sample prepared for FT dating, removing the static electricity of the sample is essential to avoid an unexpected movement of the cantilever. A grain should be wider than about 30 μm to bring the cantilever on the mineral surface. Polishing with a fine grained compound is very important. There is not much difference in sharpness between images by AC mode (scanning with vibrating cantilever at a constant cycle) and Contact mode (scanning with the cantilever always in close contact with the surface). To confirm how tracks can be identified with the AFM, an AFM image was compared with an image obtained with the optical microscope. When change in the number of tracks and their shapes were observed through stepwise etching, the track expanded as the etching time increased. In addition, the etching rate was slower for large tracks than those for small tracks. This implied that the AFM can be used to observe etching of zircons with different degrees of nuclear fission damage. A track that could not be seen with the optical microscope due to insufficient etching could be observed by

  14. 21 CFR 175.365 - Vinylidene chloride copolymer coatings for polycarbonate film.

    Science.gov (United States)

    2010-04-01

    ... polycarbonate film. 175.365 Section 175.365 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... chloride copolymer coatings for polycarbonate film. Vinylidene chloride copolymer coatings identified in this section and applied on polycarbonate film may be safely used as food-contact surfaces, in...

  15. Three-Dimensional Printing of Bisphenol A-Free Polycarbonates.

    Science.gov (United States)

    Zhu, Wei; Pyo, Sang-Hyun; Wang, Pengrui; You, Shangting; Yu, Claire; Alido, Jeffrey; Liu, Justin; Leong, Yew; Chen, Shaochen

    2018-02-14

    Polycarbonates are widely used in food packages, drink bottles, and various healthcare products such as dental sealants and tooth coatings. However, bisphenol A (BPA) and phosgene used in the production of commercial polycarbonates pose major concerns to public health safety. Here, we report a green pathway to prepare BPA-free polycarbonates (BFPs) by thermal ring-opening polymerization and photopolymerization. Polycarbonates prepared from two cyclic carbonates in different mole ratios demonstrated tunable mechanical stiffness, excellent thermal stability, and high optical transparency. Three-dimensional (3D) printing of the new BFPs was demonstrated using a two-photon laser direct writing system and a rapid 3D optical projection printer to produce structures possessing complex high-resolution geometries. Seeded C3H10T1/2 cells also showed over 95% viability with potential applications in biological studies. By combining biocompatible BFPs with 3D printing, novel safe and high-performance biomedical devices and healthcare products could be developed with broad long-term benefits to society.

  16. Polypropylene Track Membranes for Mikro and Ultrafiltration of Chemically Aggressive Agents

    CERN Document Server

    Kravets, L I; Apel, P Yu

    2000-01-01

    A production process for track membranes on the basis of chemically resistant polymer polypropylene has been developed. Research in all stages of the formation of the polypropylene track membranes has been conducted: the main principles of the process of chemical etching of polypropylene irradiated with accelerated ions have been investigated, the most effective structure of the etchant for a selective etching of the heavy ion tracks has been selected, the parameters of etching have been optimized. A method for sensibilization of latent tracks in polypropylene by effect of solvents has been developed. It helps to reach a significant increase in etching selectivity. A method for destruction of an absorbed chromocontaining layer on the surface of polypropylene track membranes formed during etching has been elaborated. Experimental samples of the membranes for micro and ultrafiltration have been obtained and their properties have been studied in course of their exploitation in chemically aggressive agents. For t...

  17. Thermal annealing of fission tracks in fluorapatite, chlorapatite, manganoanapatite, and Durango apatite: experimental results

    International Nuclear Information System (INIS)

    Ravenhurst, C.E.; Roden-Tice, M.K.; Miller, D.S.

    2003-01-01

    It is well known that the optically measured lengths of fission tracks in apatite crystals are a function of etching conditions, crystallographic orientation of the track, composition of the crystal, and the state of thermal annealing. In this study we standardize etching conditions and optimize track length measurability by etching until etch pits formed at the surface of each apatite crystal reached widths of about 0.74 μm. Etching times using 5M HNO 3 at 21 o C were 31 s for Otter Lake, Quebec, fluorapatite; 47 s for Durango, Mexico, apatite; 33 s for Portland, Connecticut, manganoanapatite; and 11 s for Bamle, Norway, chlorapatite. An etching experiment using two etchant strengths (5M and 1.6M HNO 3 ) revealed that, despite significant differences in etch pit shape, fission-track length anisotropy with respect to crystallographic orientation of the tracks is not a chemical etching effect. A series of 227 constant-temperature annealing experiments were carried out on nuclear reactor induced tracks in oriented slices of the apatites. After etching, crystallographic orientations of tracks were measured along with their lengths. The 200-300 track lengths measured for each slice were ellipse-fitted to give the major (c crystallographic direction) and minor (a crystallographic direction) semi-axes used to calculate equivalent isotropic lengths. The equivalent isotropic length is more useful than mean length for thermal history analysis because the variation caused by anisotropy has been removed. Using normalized etching procedures and equivalent isotropic length data, we found that the fluorapatite anneals most readily, followed by Durango apatite, manganoanapatite, and lastly chlorapatite. (author)

  18. Physical and mechanical properties of mortars containing PET and PC waste aggregates.

    Science.gov (United States)

    Hannawi, Kinda; Kamali-Bernard, Siham; Prince, William

    2010-11-01

    Non-biodegradable plastic aggregates made of polycarbonate (PC) and polyethylene terephthalate (PET) waste are used as partial replacement of natural aggregates in mortar. Various volume fractions of sand 3%, 10%, 20% and 50% are replaced by the same volume of plastic. This paper investigates the physical and mechanical properties of the obtained composites. The main results of this study show the feasibility of the reuse of PC and PET waste aggregates materials as partial volume substitutes for natural aggregates in cementitious materials. Despite of some drawbacks like a decrease in compressive strength, the use of PC and PET waste aggregates presents various advantages. A reduction of the specific weight of the cementitious materials and a significant improvement of their post-peak flexural behaviour are observed. The calculated flexural toughness factors increase significantly with increasing volume fraction of PET and PC-aggregates. Thus, addition of PC and PET plastic aggregates in cementitious materials seems to give good energy absorbing materials which is very interesting for several civil engineering applications like structures subjected to dynamic or impact efforts. The present study has shown quite encouraging results and opened new way for the recycling of PC waste aggregate in cement and concrete composites. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Design Concepts of Polycarbonate-Based Intervertebral Lumbar Cages: Finite Element Analysis and Compression Testing

    Directory of Open Access Journals (Sweden)

    J. Obedt Figueroa-Cavazos

    2016-01-01

    Full Text Available This work explores the viability of 3D printed intervertebral lumbar cages based on biocompatible polycarbonate (PC-ISO® material. Several design concepts are proposed for the generation of patient-specific intervertebral lumbar cages. The 3D printed material achieved compressive yield strength of 55 MPa under a specific combination of manufacturing parameters. The literature recommends a reference load of 4,000 N for design of intervertebral lumbar cages. Under compression testing conditions, the proposed design concepts withstand between 7,500 and 10,000 N of load before showing yielding. Although some stress concentration regions were found during analysis, the overall viability of the proposed design concepts was validated.

  20. Morphology, Nucleation, and Isothermal Crystallization Kinetics of Poly(Butylene Succinate Mixed with a Polycarbonate/MWCNT Masterbatch

    Directory of Open Access Journals (Sweden)

    Thandi P. Gumede

    2018-04-01

    Full Text Available In this study, nanocomposites were prepared by melt blending poly(butylene succinate (PBS with a polycarbonate (PC/multi-wall carbon nanotubes (MWCNTs masterbatch, in a twin-screw extruder. The nanocomposites contained 0.5, 1.0, 2.0, and 4.0 wt% MWCNTs. Differential scanning calorimetry (DSC, small angle X-ray scattering (SAXS and wide angle X-ray scattering (WAXS results indicate that the blends are partially miscible, hence they form two phases (i.e., PC-rich and PBS-rich phases. The PC-rich phase contained a small amount of PBS chains that acted as a plasticizer and enabled crystallization of the PC component. In the PBS-rich phase, the amount of the PC chains present gave rise to increases in the glass transition temperature of the PBS phase. The presence of two phases was supported by scanning electron microscopy (SEM and atomic force microscopy (AFM analysis, where most MWCNTs aggregated in the PC-rich phase (especially at the high MWCNTs content of 4 wt% and a small amount of MWCNTs were able to diffuse to the PBS-rich phase. Standard DSC scans showed that the MWCNTs nucleation effects saturated at 0.5 wt% MWCNT content on the PBS-rich phase, above this content a negative nucleation effect was observed. Isothermal crystallization results indicated that with 0.5 wt% MWCNTs the crystallization rate was accelerated, but further increases in MWCNTs loading (and also in PC content resulted in progressive decreases in crystallization rate. The results are explained by increased MWCNTs aggregation and reduced diffusion rates of PBS chains, as the masterbatch content in the blends increased.

  1. An energy and direction independent fast neutron dosemeter based on electrochemically etched CR-39 nuclear track detectors

    International Nuclear Information System (INIS)

    James, K.; Matiullah; Durrani, S.A.

    1987-01-01

    A computer-based model is presented, which simulates the dose equivalent response of electrochemically etched CR-39 to fast neutrons of various energies and angles of incidence. Most previous calculations of the response of CR-39 have neglected the production of recoiling oxygen and carbon nuclei as well as α particles in the CR-39. We calculate that these 'heavy recoils' and α particles are the major source of electrochemically etchable tracks in bare CR-39 at neutron energies above approx. 2 MeV under typical etching conditions. Our calculations have been extended to predict the response of CR-39 used in conjunction with various combinations of polymeric front radiators and we have determined the radiator stack configuration with produces the most energy independent response. Again, the heavy recoils and α particles cannot be neglected and, for energies above approx. 2 MeV, these produce typically about 20% of the total response of our optimum stack. This type of fast neutron dosemeter is, however, strongly direction dependent. We have integrated the response over all appropriate angles to predict the dose equivalent response for two representative neutron fields, and we suggest a method for minimising the angular dependence. (author)

  2. Texture Analysis of Hydrophobic Polycarbonate and Polydimethylsiloxane Surfaces via Persistent Homology

    Directory of Open Access Journals (Sweden)

    Ali Nabi Duman

    2017-09-01

    Full Text Available Due to recent climate change-triggered, regular dust storms in the Middle East, dust mitigation has become the critical issue for solar energy harvesting devices. One of the methods to minimize and prevent dust adhesion and create self-cleaning abilities is to generate hydrophobic characteristics on surfaces. The purpose of this study is to explore the topological features of hydrophobic surfaces. We use non-standard techniques from topological data analysis to extract morphological features from the AFM images. Our method recovers most of the previous qualitative observations in a robust and quantitative way. Persistence diagrams, which is a summary of topological structures, witness quantitatively that the crystallized polycarbonate (PC surface possesses spherulites, voids, and fibrils, and the texture height and spherulite concentration increases with the increased immersion period. The approach also shows that the polydimethylsiloxane (PDMS exactly copied the structures at the PC surface but 80 to 90 percent of the nanofibrils were not copied at PDMS surface. We next extract a feature vector from each persistence diagram to show which experiments hold features with similar variance using principal component analysis (PCA. The K-means clustering algorithm is applied to the matrix of feature vectors to support the PCA result, grouping experiments with similar features.

  3. The gamma radiation interaction with the polycarbonate Durolon

    International Nuclear Information System (INIS)

    Miranda, A.; Sciani, V.

    1994-01-01

    The effect of gamma irradiation on a polycarbonate Durolon, produced by the brazilian industries has been observed by means of stress-strain, transmittance and intrinsic viscosity measurements. The results obtained showed a good mechanical stability and that the degradation of polycarbonate increases with the water content during irradiation. (author). 8 refs, 5 figs, 1 tab

  4. Lignite and tin ores exploration in southern part of Thailand by using nuclear track-etch detectors

    International Nuclear Information System (INIS)

    Chittrakarn, T.; Boonnummar, R.; Pongsuwan, T.; Nuannin, P.; Kaew-On, C.

    1993-01-01

    Both lignite and tin mines in Southern of Thailand are associated with uranium ore. In lignite exploration, Bangpudum Lignite Mine at Krabi Province was chosen for this studied because we know the exact location and deposition of coal seam by using other geophysical technique and also confirm by borehole. The size 1x2 cm 2 of cellulose nitrate CN-85 films were used, each film was stuck at the inner bottom of a softdrink cup. Each cup was put up side down at the bottom of a borehole about 75 cm depth from the earth surface and laid about 10 m apart. All the cups were put in the hole along the line in order to cover about 280 metre in the cross sectional direction long of the known coal seam. After one month, all the film detectors were collected and etched with 6.25N NaOH at 60 o C about 25 minutes long in order to enlarge the latent alpha registration tracks. These alpha particles were emitted from radon gas (Rn-222) which was generated from uranium associated with lignite ore. The registration track density per area of each CN-85 film was studied by optical microscope at 400x magnifications. We found that the track densities of the films have high correlation with the depth of the known coal seam while high and low track densities will correspond to the shallow and deep coal seam respectively. Also, track density was significantly higher than background. A similar manner of experiment was designed for tin ore exploration at Ronpibul district, Nakorn Si Thammarat province. The result is in progress and will present at the conference. (Author)

  5. Thermal conductivity and stability of a three-phase blend of carbon nanotubes, conductive polymer, and silver nanoparticles incorporated into polycarbonate nanocomposites

    KAUST Repository

    Patole, Archana

    2015-04-16

    Metallic and non-metallic nanofillers can be used together in the design of polycarbonate (PC) nanocomposites with improved electrical properties. Here, the preparation of three-phase blend (carbon nanotubes (CNT), silver nanoparticles, and conductive polymer) in a two-step process before incorporation in the PC is reported. First, ethylene diamine functionalized multiwall carbon nanotubes (MWCNT-EDA) were decorated with Ag nanoparticles. Next, the Ag-decorated CNTs were coated with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). Due to the high thermal conductivity instrinsic to both metallic and non-metallic phases, it is expected that the thermal properties of the resulting nanocomposite would largely differ from those of pristine PC. We thus investigated in detail how this hybrid conductive blend affected properties such as the glass transition temperature, the thermal stability, and the thermal conductivity of the nanocomposite. It was found that this strategy results in improved thermal conductivity and thermal stability of the material. © 2015 Wiley Periodicals, Inc.

  6. Thermal conductivity and stability of a three-phase blend of carbon nanotubes, conductive polymer, and silver nanoparticles incorporated into polycarbonate nanocomposites

    KAUST Repository

    Patole, Archana; Ventura, Isaac Aguilar; Lubineau, Gilles

    2015-01-01

    Metallic and non-metallic nanofillers can be used together in the design of polycarbonate (PC) nanocomposites with improved electrical properties. Here, the preparation of three-phase blend (carbon nanotubes (CNT), silver nanoparticles, and conductive polymer) in a two-step process before incorporation in the PC is reported. First, ethylene diamine functionalized multiwall carbon nanotubes (MWCNT-EDA) were decorated with Ag nanoparticles. Next, the Ag-decorated CNTs were coated with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). Due to the high thermal conductivity instrinsic to both metallic and non-metallic phases, it is expected that the thermal properties of the resulting nanocomposite would largely differ from those of pristine PC. We thus investigated in detail how this hybrid conductive blend affected properties such as the glass transition temperature, the thermal stability, and the thermal conductivity of the nanocomposite. It was found that this strategy results in improved thermal conductivity and thermal stability of the material. © 2015 Wiley Periodicals, Inc.

  7. Use of CR-39 foils for personnel neutron dosimetry: improved electrochemical etching chambers and procedures

    International Nuclear Information System (INIS)

    Hankins, D.E.; Homann, S.G.; Westermark, J.

    1986-01-01

    The electrochemical etching procedures for the new dosimetry system that uses foils of CR-39 plastic has been improved. During 1985, the etching chambers were modified to correct several problems and the changes to the etching procedures were studied, which gave a more uniform track density and size. The currently recommended etch parameters are given. A new generation of CR-39 material from the manufacturer proved to have a considerably lower background track density and a higher sensitivity; the new foils are also more uniform in thickness, which eliminates the need to numerically compensate for thickness variations. The energy dependence of the CR-39 using monoenergetic neutrons from accelerators at Battelle Northwest Laboratories and at Los Alamos National Laboratory was determined. Some variation was found in the energy dependence, but it is believed this was caused by changes in the etching procedures and by uncertainties in the fluences of the neutrons from the accelerators. A means by which the counting of CR-39 tracks may be automated is suggested; this would be very useful in adapting the CR-39 dosimetry system to large-scale use

  8. Peak Pc Prediction in Conjunction Analysis: Conjunction Assessment Risk Analysis. Pc Behavior Prediction Models

    Science.gov (United States)

    Vallejo, J.J.; Hejduk, M.D.; Stamey, J. D.

    2015-01-01

    Satellite conjunction risk typically evaluated through the probability of collision (Pc). Considers both conjunction geometry and uncertainties in both state estimates. Conjunction events initially discovered through Joint Space Operations Center (JSpOC) screenings, usually seven days before Time of Closest Approach (TCA). However, JSpOC continues to track objects and issue conjunction updates. Changes in state estimate and reduced propagation time cause Pc to change as event develops. These changes a combination of potentially predictable development and unpredictable changes in state estimate covariance. Operationally useful datum: the peak Pc. If it can reasonably be inferred that the peak Pc value has passed, then risk assessment can be conducted against this peak value. If this value is below remediation level, then event intensity can be relaxed. Can the peak Pc location be reasonably predicted?

  9. Effects of gamma radiation in mechanical and optical properties of polycarbonate

    International Nuclear Information System (INIS)

    Araujo, E.S.; Khoury, H.J.; Silveira, S.V. da; Dallolio, A.

    1990-01-01

    The polycarbonates are used in different industrial applications due to their excellent dielectric proprieties, impact resistance and high temperature resistance. For some of this applications, the polycarbonates are exposed to gamma radiation which produces a molecular scission, occasioning changes in the polycarbonate proprieties. To estimate the radiation effects in the DUROLON polycarbonate, samples were irradiated with sup(60)Co gamma beam with doses between 0,2kGy and 50kGy. The results obtained shown variations in the yellowness index above 1kGy dose. Their mechanical proprieties are not changed in the above dose interval. (author)

  10. Modification of Low Refractive Index Polycarbonate for High Refractive Index Applications

    Directory of Open Access Journals (Sweden)

    Gunjan Suri

    2009-01-01

    Full Text Available Polycarbonates and polythiourethanes are the most popular materials in use today, for optical applications. Polycarbonates are of two types which fall in the category of low refractive index and medium refractive index. The present paper describes the conversion of low refractive index polycarbonates into high refractive index material by the use of a high refractive index monomer, polythiol, as an additive. Novel polycarbonates, where the properties of refractive index and Abbe number can be tailor made, have been obtained. Thermal studies and refractive index determination indicate the formation of a new polymer with improved properties and suitable for optical applications.

  11. Using track detectors in neutron dosimetry

    International Nuclear Information System (INIS)

    Spurny, F.; Turek, K.

    1977-01-01

    The usage of track detectors of charged particles provides a new possibility of neutron dosimetry. Presented is a comparison of the main dosimetric characteristics of three various types of track detectots of fast neutrons, i.e. glass in the contact with 232 Th; KODAK LR115 cellulose nitrate; MAKROFOL E polycarbonate. Results of studing energy dependences of detectors are presented. Results obtained using phantoms under radiation fields of various sources of complex gamma-neutron radiation are discussed [ru

  12. A study of the effect of natural radiation damage in a zircon crystal using thermoluminescence, fission track etching and X-ray diffraction

    International Nuclear Information System (INIS)

    Amin, Y.M.

    1989-01-01

    The natural radiation damage in zircon caused by the decay of uranium and thorium, present as impurities, is studied. The radiation damage is first gauged by etching the fission tracks. It is found that thermoluminescence (TL) sensitivity (defined as light output per unit test-dose) decreases as the radiation damage increases, suggesting a destruction of TL centers. The spacing d of the (112)-plane is also measured. It is also found that the d-value increases with radiation damage, suggesting the displacement of atoms from their normal lattice sites. However, as the track density increases beyond ≅ 3x10 6 tracks/cm 2 , the d-value remains at ≅ 2.52 A. By annealing the crystal, the displaced atoms are found to return to the original lattice sites, and this is followed by a reduction in d-value as well as the recovery of TL sensitivity. The fission track density also decreases and all the tracks disappear at the annealing temperature of ≅ 800 0 C. (orig.)

  13. Flame retardancy mechanisms of bisphenol A bis(diphenyl phosphate) in combination with zinc borate in bisphenol A polycarbonate/acrylonitrile-butadiene-styrene blends

    International Nuclear Information System (INIS)

    Pawlowski, Kristin H.; Schartel, Bernhard; Fichera, Mario A.; Jaeger, Christian

    2010-01-01

    Bisphenol A polycarbonate/acrylonitrile-butadiene-styrene (PC/ABS) with and without bisphenol A bis(diphenyl phosphate) (BDP) and 5 wt.% zinc borate (Znb) were investigated. The pyrolysis was studied by thermogravimetry (TG), TG-FTIR and NMR, the fire behaviour with a cone calorimeter applying different heat fluxes, LOI and UL 94. Fire residues were examined with NMR. BDP affects the decomposition of PC/ABS and acts as a flame retardant in the gas and condensed phases. The addition of Znb results in an additional hydrolysis of PC. The fire behaviour is similar to PC/ABS, aside from a slightly increased LOI and a reduced peak heat release rate, both caused by borates improving the barrier properties of the char. In PC/ABS + BDP + Znb, the addition of Znb yields a borate network and amorphous phosphates. Znb also reacts with BDP to form alpha-zinc phosphate and borophosphates that suppress the original flame retardancy mechanisms of BDP. The inorganic-organic residue formed provides more effective flame retardancy, in particular at low irradiation in the cone calorimeter, and a clear synergy in LOI, whereas for more developed fires BDP + Znb become less effective than BDP in PC/ABS with respect to the total heat evolved.

  14. Comparative catalytic activity of PET track-etched membranes with embedded silver and gold nanotubes

    Science.gov (United States)

    Mashentseva, Anastassiya; Borgekov, Daryn; Kislitsin, Sergey; Zdorovets, Maxim; Migunova, Anastassiya

    2015-12-01

    Irradiated by heavy ions nanoporous polyethylene terephthalate track-etched membranes (PET TeMs) after +15Kr84 ions bombardment (1.75 MeV/nucl with the ion fluency of 1 × 109 cm-2) and sequential etching was applied in this research as a template for development of composites with catalytically enriched properties. A highly ordered silver and gold nanotubes arrays were embedded in 100 nm pores of PET TeMs via electroless deposition technique at 4 °C during 1 h. All "as-prepared" composites were examined for catalytic activity using reduction of 4-nitrophenol (4-NP) to 4-aminophenol (4-AP) by sodium borohydride as a common reaction to test metallic nanostructures catalysts. The effect of temperature on the catalytic activity was investigated in range of 292-313 K and activation energy were calculated. Kapp of Ag/PET composites linearly increase with an increase of the temperature thus normal Arrhenius behavior have been seen and the activation energy was calculated to be 42.13 kJ/mol. Au/PET composites exhibit not only more powerful catalytic activity but also non-linear dependence of rate constant from temperature. Kapp increased with increasing temperature throughout the 292-308 K temperature range; the reaction had an activation energy 65.32 kJ/mol. In range 311-313 K rate constant dramatically decreased and the apparent activation energy at this temperature rang was -91.44 kJ/mol due some structural changes, i.e. agglomeration of Au nanoparticles on the surface of composite.

  15. Response of cellulose nitrate track detectors to electron doses

    CERN Document Server

    Segovia, N; Moreno, A; Vazquez-Polo, G; Santamaría, T; Aranda, P; Hernández, A

    1999-01-01

    In order to study alternative dose determination methods, the bulk etching velocity and the latent track annealing of LR 115 track detectors was studied during electron irradiation runs from a Pelletron accelerator. For this purpose alpha irradiated and blank detectors were exposed to increasing electron doses from 10.5 to 317.5 kGy. After the irradiation with electrons the detectors were etched under routine conditions, except for the etching time, that was varied for each electron dose in order to reach a fixed residual thickness. The variation of the bulk etching velocity as a function of each one of the electron doses supplied, was interpolated in order to obtain dosimetric response curves. The observed annealing effect on the latent tracks is discussed as a function of the total electron doses supplied and the temperature.

  16. Fission track analysis of Pu in small specimens of biological material: Technical progress report, August 1, 1987--July 31, 1988

    International Nuclear Information System (INIS)

    Wrenn, M.E.

    1988-01-01

    The objective of this research is to develop a highly specific and ultrasensitive method capable of detecting 100 aCi/liter of 239 Pu in human urine. The method using neutron induced fission track analysis is to be made free of interference from uranium, the only naturally occurring element with an isotope which fissions with thermal neutrons. A simplified flow diagram for the method is shown in Figure 1. Briefly 239 Pu is coprecipitated quantitatively from urine with rhodozonic acid. The precipitate containing the 239 Pu is dissolved in HCl and is sequentially passed through two ion exchange columns and reduced in volume. The element is then deposited in a circular area on a thick polycarbonate detector and a thinner detector is placed over the circular deposit. The plastic detectors are then irradiated to a high thermal neutron fluence in a research reactor. The detectors are etched in a caustic solution for controlled times and temperatures in order to develop the fission tracks. Images of tracks are formed both on the thin and thick plastic detectors. Total tracks in the thinner detector are measured with a locally developed spark counter and in the thick plastic are measured by counting with a microscope. The results will be made quantitative by constructing a calibration curve for 239 Pu. 3 refs., 9 figs., 3 tabs

  17. Field calibration of PADC track etch detectors for local neutron dosimetry in man using different radiation qualities

    Energy Technology Data Exchange (ETDEWEB)

    Haelg, Roger A., E-mail: rhaelg@phys.ethz.ch [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Besserer, Juergen [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Boschung, Markus; Mayer, Sabine [Division for Radiation Safety and Security, Paul Scherrer Institut, CH-5232 Villigen (Switzerland); Clasie, Benjamin [Department of Radiation Oncology, Massachusetts General Hospital, 30 Fruit Street, Boston, MA 02114 (United States); Kry, Stephen F. [Department of Radiation Physics, The University of Texas M.D. Anderson Cancer Center, 1515 Holcombe Blvd., Houston, TX 77030 (United States); Schneider, Uwe [Institute for Radiotherapy, Radiotherapie Hirslanden AG, Hirslanden Medical Center, Rain 34, CH-5000 Aarau (Switzerland); Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 204, CH-8057 Zurich (Switzerland)

    2012-12-01

    In order to quantify the dose from neutrons to a patient for contemporary radiation treatment techniques, measurements inside phantoms, representing the patient, are necessary. Published reports on neutron dose measurements cover measurements performed free in air or on the surface of phantoms and the doses are expressed in terms of personal dose equivalent or ambient dose equivalent. This study focuses on measurements of local neutron doses inside a radiotherapy phantom and presents a field calibration procedure for PADC track etch detectors. An initial absolute calibration factor in terms of H{sub p}(10) for personal dosimetry is converted into neutron dose equivalent and additional calibration factors are derived to account for the spectral changes in the neutron fluence for different radiation therapy beam qualities and depths in the phantom. The neutron spectra used for the calculation of the calibration factors are determined in different depths by Monte Carlo simulations for the investigated radiation qualities. These spectra are used together with the energy dependent response function of the PADC detectors to account for the spectral changes in the neutron fluence. The resulting total calibration factors are 0.76 for a photon beam (in- and out-of-field), 1.00 (in-field) and 0.84 (out-of-field) for an active proton beam and 1.05 (in-field) and 0.91 (out-of-field) for a passive proton beam, respectively. The uncertainty for neutron dose measurements using this field calibration method is less than 40%. The extended calibration procedure presented in this work showed that it is possible to use PADC track etch detectors for measurements of local neutron dose equivalent inside anthropomorphic phantoms by accounting for spectral changes in the neutron fluence.

  18. Characterization of ZnO film grown on polycarbonate by atomic layer deposition at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyeong Beom; Han, Gwon Deok; Shim, Joon Hyung; Choi, Byoung-Ho, E-mail: bhchoi@korea.ac.kr [School of Mechanical Engineering, Korea University, Seoul 136-707 (Korea, Republic of)

    2015-01-15

    ZnO is an attractive material for use in various technological products such as phosphors, gas sensors, and transparent conductors. Recently, aluminum-doped zinc oxide has received attention as a potential replacement for indium tin oxide, which is one of the transparent conductive oxides used in flat panel displays, organic light-emitting diodes, and organic solar cells. In this study, the characteristics of ZnO films deposited on polycarbonate (PC) substrates by atomic layer deposition (ALD) are investigated for various process temperatures. The growth mechanism of these films was investigated at low process temperatures using x-ray diffraction (XRD) and x-ray photoelectron spectroscopy (XPS). XRD and XPS were used to determine the preferred orientation and chemical composition of the films, respectively. Furthermore, the difference of the deposition mechanisms on an amorphous organic material, i.e., PC substrate and an inorganic material such as silicon was discussed from the viewpoint of the diffusion and deposition of precursors. The structure of the films was also investigated by chemical analysis in order to determine the effect of growth temperature on the films deposited by ALD.

  19. Radiation protection of polyhydroxybutyrate by blending with bisphenol-A polycarbonate

    International Nuclear Information System (INIS)

    Nalbandi, A.; Hill, D.

    2000-01-01

    Full text: Polyhydroxybutyrate (PHB), a bacterially produced aliphatic biopolymers commonly used in medical applications, was blended with the aromatic polymer of polycarbonate (PC) in the range 0-100 wt. % of PHB. The polymer parents, PHB and PC, and their blends were irradiated in a cobalt-60 Gamma cell source. The radiation sensitivity of polymers was quantified, as the yield of radical formation, using an electron spin resonance (ESR). These values were then plotted against weight percent of PHB. The resulted pattern does not match with the 'Law of averages' line drawn mathematically, instead a negative deviation has been observed. The radiation sensitivity of polymers is greatly dependent on their chemical structures. For poly(methylmethacrylate) the main effect to irradiation is chain scission with little or no crosslinking. However, for polystyrene the main effect is crosslinking with only a small amount of chain scission. Some researchers have studied the radiation sensitivity of aliphatic and aromatic hydrocarbons. Schoepfle et al. exposed benzene and cyclohexane to cathode rays. Manion and Burton investigated the radiation sensitivity of the mixture of aliphatic and aromatic hydrocarbons. Their studies showed that exposure of a mixture of benzene and cyclohexane to ionizing radiation gives a yield of hydrogen which is less than that is predictable from the Law of averages. The present research was carried out to investigate whether the radiation protection of PHB can occur by the incorporation of PC. Polymer blends of PHB and PC were prepared using chloroform/methanol as solvent/nonsolvent system. The polymer parents and their blends were freeze-grinded, packed in Spectrosil ESR tubes and connected to vacuum line for oxygen evacuation before sealing and irradiation. Also a series of DSC experiments were carried out on the blend samples to elucidate their morphology. The resulted pattern of the plot of sensitivity vs. wt.% of PHB negatively deviates from

  20. Selective Functionalization of Arbitrary Nanowires

    Science.gov (United States)

    2006-11-02

    3-mercaptopropyl)- trimethoxysilane (MPTMS). The wires were grown electrochemically in anodic aluminum oxide ( AAO ) templates. Selective deposition...In the past, templates composed of polycarbonate track-etched membranes or anodic aluminum oxide materials have been used for the construction of...modifier MPTMS was used to function- alize the AAO template because it can form covalent bonds with silanes and metal oxide surfaces21 and because of

  1. The oxidation of PET track-etched membranes by hydrogen peroxide as an effective method to increase efficiency of UV-induced graft polymerization

    OpenAIRE

    Il'ya Korolkov; Abzal Taltenov; Anastassiya Mashentseva; Olgun Guven

    2015-01-01

    In this article, we report on functionalization of track-etched membrane based on poly(ethylene terephthalate) (PET TeMs) oxidized by advanced oxidation systems and by grafting of acrylic acid using photochemical initiation technique for the purpose of increasing functionality thus expanding its practical application. Among advanced oxidation processes (H2O2/UV) system had been chosen to introduce maximum concentration of carboxylic acid groups. Benzophenone (BP) photo-initiator was first im...

  2. Nuclear track detector kit for use in teaching

    Energy Technology Data Exchange (ETDEWEB)

    Medveczky, L.; Somogyi, G.; Nagy, M.

    1986-01-01

    By the use of solid state nuclear track detectors (SSNTDs) one may carry out several useful and impressive educational experiments and demonstrations to illustrate different phenomena when teaching of nuclear physics. Realizing this situation the authors have published, since 1970, reports on several experiments for teaching demonstrations. Based on the authors instructions, a factory in Hungary (TANFRT, National Manufacturers and Suppliers of School Equipment, Budapest) constructed a kit for the use of nuclear track detectors in teaching. The portable kit contains the following items: alpha-emitting weak sources, solid state nuclear track detectors (unirradiated, irradiated, unetched and etched sheets), simple tools for carrying out experiments (facilities for irradiation and etching, etc.), slides showing photos of typical etch-tracks of light and heavy nuclei, user manual. By the help of the kit both pupils and teachers can perform various useful experiments and/or demonstrations.

  3. Experimental and computational investigation of lateral gauge response in polycarbonate

    Science.gov (United States)

    Eliot, Jim; Harris, Ernst; Hazell, Paul; Appleby-Thomas, Gareth; Winter, Ronald; Wood, David; Owen, Gareth

    2011-06-01

    Polycarbonate's use in personal armour systems means its high strain-rate response has been extensively studied. Interestingly, embedded lateral manganin stress gauges in polycarbonate have shown gradients behind incident shocks, suggestive of increasing shear strength. However, such gauges need to be embedded in a central (typically) epoxy interlayer - an inherently invasive approach. Recently, research has suggested that in such metal systems interlayer/target impedance may contribute to observed gradients in lateral stress. Here, experimental T-gauge (Vishay Micro-Measurements® type J2M-SS-580SF-025) traces from polycarbonate targets are compared to computational simulations. This work extends previous efforts such that similar impedance exists between the interlayer and matrix (target) interface. Further, experiments and simulations are presented investigating the effects of a ``dry joint'' in polycarbonate, in which no encapsulating medium is employed.

  4. Track detection methods of radium measurements

    International Nuclear Information System (INIS)

    Somogyi, G.

    1986-06-01

    The principles of tack formation and processing including the description of etching and etch-track evaluation for the preferably used plastic track detectors are discussed. Measuring methods to determine 226 Ra activity based either on the mapping of alpha-decaying elements in the complete U-Ra series by alpha-radiography, or on the measurement of uranium alone by neutron induced fissionography, or on the alpha-decay measurement of 222 Rn, the first daughter element of radium, and finally on the measurement of alpha-tracks originating from radium itself, which is separated from its parent nuclides are described in detail. (V.N.)

  5. Kinetics and mechanism of the formation and etching of particle tracks in polyethylene-terephthalate

    International Nuclear Information System (INIS)

    Lueck, H.B.

    1982-05-01

    The physical and chemical processes initiated by a particle passing through a polymer are reviewed. Particular attention is devoted to the processes in PETP. The influence of the material parameters and environmental effects on the subsequent reactions in PETP is discussed. Models of the mechanism and kinetics of the alkaline degradation on the surface and in the etch channel are presented. The character and the effect of the relevant species has been taken into consideration. The mechanism of the photo-oxidative sensitivity enhancement is discussed. The models mentioned above are taken as a basis to interpret the empirical response function. It is shown, that the response function can be applied to bulk-irradiated polymers as well. Treeing in electrically stressed particle tracks assisted by an etchant can be attributed to the electrostatic pressure. However, the differences in the behaviour of the structures give evidence, that the formation of craze structures and bubbles in the presence of a nonetching electrolyte is the result of the electroosmotic pressure. (author)

  6. Surface free energy of polypropylene and polycarbonate solidifying at different solid surfaces

    International Nuclear Information System (INIS)

    Chibowski, Emil; Terpilowski, Konrad

    2009-01-01

    Advancing and receding contact angles of water, formamide, glycerol and diiodomethane were measured on polypropylene (PP) and polycarbonate (PC) sample surfaces which solidified at Teflon, glass or stainless steel as matrix surfaces. Then from the contact angle hystereses (CAH) the apparent free energies γ s tot of the surfaces were evaluated. The original PP surface is practically nonpolar, possessing small electron donor interaction (γ s - =1.91mJ/m 2 ), as determined from the advancing contact angles of these liquids. It may result from impurities of the polymerization process. However, it increases up to 8-10 mJ/m 2 for PP surfaces contacted with the solids. The PC surfaces both original and modified show practically the same γ s - =6.56.7mJ/m 2 . No electron acceptor interaction is found on the surfaces. The γ s tot of modified PP and PC surfaces depend on the kind of probe liquid and contacted solid surface. The modified PP γ s tot values determined from CAH of polar liquids are greater than that of original surface and they increase in the sequence: Teflon, glass, stainless steel surface, at which they solidified. No clear dependence is observed between γ s tot and dielectric constant or dipole moment of the polar probe liquids. The changes in γ s tot of the polymer surfaces are due to the polymer nature and changes in its surface structure caused by the structure and force field of the contacting solid. It has been confirmed by AFM images.

  7. Electrodeposited Ni nanowires-track etched P.E.T. composites as selective solar absorbers

    Science.gov (United States)

    Lukhwa, R.; Sone, B.; Kotsedi, L.; Madjoe, R.; Maaza, M.

    2018-05-01

    This contribution reports on the structural, optical and morphological properties of nanostructured flexible solar-thermal selective absorber composites for low temperature applications. The candidate material in the system is consisting of electrodeposited nickel nano-cylinders embedded in track-etched polyethylene terephthalate (PET) host membrane of pore sizes ranging between 0.3-0.8µm supported by conductive nickel thin film of about 0.5µm. PET were irradiated with 11MeV/u high charged xenon (Xe) ions at normal incidence. The tubular and metallic structure of the nickel nano-cylinders within the insulator polymeric host forms a typical ceramic-metal nano-composite "Cermet". The produced material was characterized by the following techniques: X-ray diffraction (XRD) for structural characterization to determine preferred crystallographic structure, and grain size of the materials; Scanning electron microscopy (SEM) to determine surface morphology, particle size, and visual imaging of distribution of structures on the surface of the substrate; Atomic force microscopy (AFM) to characterize surface roughness, surface morphology, and film thickness, and UV-Vis-NIR spectrophotometer to measure the reflectance, then to determine solar absorption

  8. The combined effect of gamma radiation and stress cracking in polycarbonate;Efeito combinado da radiacao gama e stress cracking no policarbonato

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Raphaela N. de; Rabello, Marcelo S., E-mail: marcelo@dema.ufcg.edu.b [Universidade Federal de Campina Grande (DEMa/UFCG), PB (Brazil). Dept. de Engenharia de Materiais; Silva, Leonardo G.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    In this work the combined effect of gamma irradiation and stress cracking was studied in polycarbonate (PC). Tensile test bars were produced by injection moulding and then exposed to different doses of gamma radiation. After that they were submitted to the contact with isopropanol, the stress cracking agent used in this work. The specimens were tested for mechanical properties, viscosity molecular weight and fractography. The results indicated that the previous radiation intensified the stress cracking effects, as evidenced by the reduction in tensile properties and surface damage caused to the samples. (author)

  9. Structural characterization of swift heavy ion irradiated polycarbonate

    International Nuclear Information System (INIS)

    Singh, Lakhwant; Samra, Kawaljeet Singh

    2007-01-01

    Makrofol-N polycarbonate thin films were irradiated with copper (50 MeV) and nickel (86 MeV) ions. The modified films were analyzed by UV-VIS, FTIR and XRD techniques. The experimental data was used to evaluate the formation of chromophore groups (conjugated system of bonds), degradation cross-section of the special functional groups, the alkyne formation and the amorphization cross-section. The investigation of UV-VIS spectra shows that the formation of chromophore groups is reduced at larger wavelength, however its value increases with the increase of ion fluence. Degradation cross-section for the different chemical groups present in the polycarbonate chains was evaluated from the FTIR data. It was found that there was an increase of degradation cross-section of chemical groups with the increase of electronic energy loss in polycarbonate. The alkyne and alkene groups were found to be induced due to swift heavy ion irradiation in polycarbonate. The radii of the alkyne production of about 2.74 and 2.90 nm were deduced for nickel (86 MeV) and copper (50 MeV) ions respectively. XRD analysis shows the decrease of the main XRD peak intensity. Progressive amorphization process of Makrofol-N with increasing fluence was traced by XRD measurements

  10. Diffusion kinetics of the glucose/glucose oxidase system in swift heavy ion track-based biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Fink, Dietmar, E-mail: fink@xanum.uam.mx [Nuclear Physics Institute, 25068 Řež (Czech Republic); Departamento de Fisica, Universidad Autónoma Metropolitana-Iztapalapa, PO Box 55-534, 09340 México, DF (Mexico); Vacik, Jiri; Hnatowicz, V. [Nuclear Physics Institute, 25068 Řež (Czech Republic); Muñoz Hernandez, G. [Departamento de Fisica, Universidad Autónoma Metropolitana-Iztapalapa, PO Box 55-534, 09340 México, DF (Mexico); Garcia Arrelano, H. [Departamento de Ciencias Ambientales, División de Ciencias Biológicas y de la Salud, Universidad Autónoma Metropolitana-Lerma, Av. de las Garzas No. 10, Col. El Panteón, Lerma de Villada, Municipio de Lerma, Estado de México CP 52005 (Mexico); Alfonta, Lital [Avram and Stella Goldstein-Goren Department of Biotechnology Engineering, Ben-Gurion University of the Negev, PO Box 653, Beer-Sheva 84105 (Israel); Kiv, Arik [Department of Materials Engineering, Ben-Gurion University of the Negev, PO Box 653, Beer-Sheva 84105 (Israel)

    2017-05-01

    Highlights: • Application of swift heavy ion tracks in biosensing. • Obtaining yet unknown diffusion coefficients of organic matter across etched ion tracks. • Obtaining diffusion coefficients of organics in etched ion tracks of biosensors. • Comparison with Renkin’s equation to predict the effective etched track diameter in the given experiments. - Abstract: For understanding of the diffusion kinetics and their optimization in swift heavy ion track-based biosensors, recently a diffusion simulation was performed. This simulation aimed at yielding the degree of enrichment of the enzymatic reaction products in the highly confined space of the etched ion tracks. A bunch of curves was obtained for the description of such sensors that depend only on the ratio of the diffusion coefficient of the products to that of the analyte within the tracks. As hitherto none of these two diffusion coefficients is accurately known, the present work was undertaken. The results of this paper allow one to quantify the previous simulation and hence yield realistic predictions of glucose-based biosensors. At this occasion, also the influence of the etched track radius on the diffusion coefficients was measured and compared with earlier prediction.

  11. Thermal energy harvesting for large-scale applications using MWCNT-grafted glass fibers and polycarbonate-MWCNT nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Tzounis, L., E-mail: ltzounis@physics.auth.gr [Leibniz-Institut für Polymerforschung Dresden e.V., IPF, Hohe Str. 6, D-01069 Dresden (Germany); Technische Universität Dresden, Helmholtzstraße 10, 01069 Dresden (Germany); Laboratory for Thin Films-Nanosystems and Nanometrolo (Greece); Liebscher, M.; Stamm, M. [Leibniz-Institut für Polymerforschung Dresden e.V., IPF, Hohe Str. 6, D-01069 Dresden, Germany and Technische Universität Dresden, Helmholtzstraße 10, 01069 Dresden (Germany); Mäder, E.; Pötschke, P. [Leibniz-Institut für Polymerforschung Dresden e.V., IPF, Hohe Str. 6, D-01069 Dresden (Germany); Logothetidis, S., E-mail: logot@auth.gr [Laboratory for Thin Films-Nanosystems and Nanometrology (LTFN), Physics Department, Aristotle University of Thessaloniki, GR-54124 Thessaloniki (Greece)

    2015-02-17

    The thermoelectric properties of multi-wall carbon nanotube (MWCNT) -grafted glass fiber yarns (GF-CNT) and their epoxy model composites, as well as of polymer nanocomposites consisting of a polycarbonate (PC) matrix filled with differently functionalized MWCNTs have been examined. The GF-CNT hierarchical multi-scale structures were prepared by dip coating glass fiber yarns in a solution of carbonyl chloride modified MWCNTs; MWCNT-COCl (at a concentration of 0.5 mg/ml) under Ar atmosphere. The resulting GF-CNT exhibited high electrical conductivity (σ = 2.1×10{sup 3} S/m) due to the dense MWCNT deposited networks. The fiber surface morphology was investigated by scanning electron microscopy (SEM). The GF-CNT showed Seebeck coefficient (S); S = 16.8 μV/K, and power factor (P.F); P.F = 0.59 μW/mK−2. The high electrical conductivity of the GF-CNT is a key parameter for an optimum thermoelectric performance, since it can facilitate the flow of the thermally induced charge carriers upon being exposed to a temperature gradient. Polycarbonate/MWCNT nanocomposites were prepared by small-scale melt-mixing process using a microcompounder. Unfunctionalized, carboxyl (-COOH) and hydroxyl (-OH) modified MWCNTs were incorporated in PC at a constant amount of 2.5 wt.%, concentration above the electrical percolation threshold. The amount of MWCNTs was kept low to understand the fundamental aspects of their physical properties and their correlation to the composite morphology, as revealed by transmission electron microscopy (TEM). It was found that different functional groups can affect the thermoelectric performance and the conductivity of the nanocomposites. Namely, the highest Seebeck coefficient (S) was found for the composite containing carboxyl functionalized MWCNTs (11.3 μV/K), due to the highest oxygen content of MWCNTs proven by X-Ray Photoelectron spectroscopy (XPS). It is believed that MWCNT-grafted glass fibers as reinforcements in composite structural

  12. Thermal energy harvesting for large-scale applications using MWCNT-grafted glass fibers and polycarbonate-MWCNT nanocomposites

    International Nuclear Information System (INIS)

    Tzounis, L.; Liebscher, M.; Stamm, M.; Mäder, E.; Pötschke, P.; Logothetidis, S.

    2015-01-01

    The thermoelectric properties of multi-wall carbon nanotube (MWCNT) -grafted glass fiber yarns (GF-CNT) and their epoxy model composites, as well as of polymer nanocomposites consisting of a polycarbonate (PC) matrix filled with differently functionalized MWCNTs have been examined. The GF-CNT hierarchical multi-scale structures were prepared by dip coating glass fiber yarns in a solution of carbonyl chloride modified MWCNTs; MWCNT-COCl (at a concentration of 0.5 mg/ml) under Ar atmosphere. The resulting GF-CNT exhibited high electrical conductivity (σ = 2.1×10 3 S/m) due to the dense MWCNT deposited networks. The fiber surface morphology was investigated by scanning electron microscopy (SEM). The GF-CNT showed Seebeck coefficient (S); S = 16.8 μV/K, and power factor (P.F); P.F = 0.59 μW/mK−2. The high electrical conductivity of the GF-CNT is a key parameter for an optimum thermoelectric performance, since it can facilitate the flow of the thermally induced charge carriers upon being exposed to a temperature gradient. Polycarbonate/MWCNT nanocomposites were prepared by small-scale melt-mixing process using a microcompounder. Unfunctionalized, carboxyl (-COOH) and hydroxyl (-OH) modified MWCNTs were incorporated in PC at a constant amount of 2.5 wt.%, concentration above the electrical percolation threshold. The amount of MWCNTs was kept low to understand the fundamental aspects of their physical properties and their correlation to the composite morphology, as revealed by transmission electron microscopy (TEM). It was found that different functional groups can affect the thermoelectric performance and the conductivity of the nanocomposites. Namely, the highest Seebeck coefficient (S) was found for the composite containing carboxyl functionalized MWCNTs (11.3 μV/K), due to the highest oxygen content of MWCNTs proven by X-Ray Photoelectron spectroscopy (XPS). It is believed that MWCNT-grafted glass fibers as reinforcements in composite structural materials

  13. PHENIX central arm tracking detectors

    International Nuclear Information System (INIS)

    Adcox, K.; Ajitanand, N.N.; Alexander, J.; Autrey, D.; Averbeck, R.; Azmoun, B.; Barish, K.N.; Baublis, V.V.; Belkin, R.; Bhaganatula, S.; Biggs, J.C.; Borland, D.; Botelho, S.; Bryan, W.L.; Burward-Hoy, J.; Butsyk, S.A.; Chang, W.C.; Christ, T.; Dietzsch, O.; Drees, A.; Rietz, R. du; El Chenawi, K.; Evseev, V.A.; Fellenstein, J.; Ferdousi, T.; Fraenkel, Z.; Franz, A.; Fung, S.Y.; Gannon, J.; Garpman, S.; Godoi, A.L.; Greene, S.V.; Gustafsson, H.-A.; Harder, J.; Hemmick, T.K.; Heuser, J.M.; Holzmann, W.; Hutter, R.; Issah, M.; Ivanov, V.I.; Jacak, B.V.; Jagadish, U.; Jia, J.; Johnson, S.C.; Kandasamy, A.; Kann, M.R.; Kelley, M.A.; Khanzadeev, A.V.; Khomutnikov, A.; Komkov, B.G.; Kopytine, M.L.; Kotchenda, L.; Kotchetkov, D.; Kozlov, V.S.; Kravtsov, P.A.; Kudin, L.G.; Kuriatkov, V.V.; Lacey, R.; Lauret, J.; Lebedev, A.; Lebedev, V.D.; Li, X.H.; Libby, B.; Liccardi, W.; Machnowski, R.; Mahon, J.; Markushin, D.G.; Matathias, F.; Marx, M.D.; Messer, F.; Miftakhov, N.M.; Milan, J.; Miller, T.E.; Milov, A.; Minuzzo, K.; Mioduszewski, S.; Mitchell, J.T.; Muniruzzamann, M.; Nandi, B.K.; Negrin, J.; Nilsson, P.; Nystrand, J.; O'Brien, E.; O'Connor, P.; Oskarsson, A.; Oesterman, L.; Otterlund, I.; Pancake, C.E.; Pantuev, V.S.; Petersen, R.; Pinkenburg, C.H.; Pisani, R.P.; Purwar, A.K.; Rankowitz, S.; Ravinovich, I.; Riabov, V.G.; Riabov, Yu.G.; Rosati, M.; Rose, A.A.; Roschin, E.V.; Samsonov, V.M.; Sangster, T.C.; Seto, R.; Silvermyr, D.; Sivertz, M.; Smith, M.; Solodov, G.P.; Stenlund, E.; Takagui, E.M.; Tarakanov, V.I.; Tarasenkova, O.P.; Thomas, J.L.; Trofimov, V.A.; Tserruya, I.; Tydesjoe, H.; Velkovska, J.; Velkovsky, M.; Vishnevskii, V.I.; Vorobyov, A.A.; Vznuzdaev, E.A.; Vznuzdaev, M.; Wang, H.Q.; Weimer, T.; Wolniewicz, K.; Wu, J.; Xie, W.; Young, G.R.

    2003-01-01

    The PHENIX tracking system consists of Drift Chambers (DC), Pad Chambers (PC) and the Time Expansion Chamber (TEC). PC1/DC and PC2/TEC/PC3 form the inner and outer tracking units, respectively. These units link the track segments that transverse the RICH and extend to the EMCal. The DC measures charged particle trajectories in the r-phi direction to determine p T of the particles and the invariant mass of particle pairs. The PCs perform 3D spatial point measurements for pattern recognition and longitudinal momentum reconstruction and provide spatial resolution of a few mm in both r-phi and z. The TEC tracks particles passing through the region between the RICH and the EMCal. The design and operational parameters of the detectors are presented and running experience during the first year of data taking with PHENIX is discussed. The observed spatial and momentum resolution is given which imposes a limitation on the identification and characterization of charged particles in various momentum ranges

  14. Nuclear track detector kit for use in teaching

    International Nuclear Information System (INIS)

    Medveczky, L.; Somogyi, G.

    1986-01-01

    By the use of solid state nuclear track detectors (SSNTDs) one may carry out several useful and impressive educational experiments and demonstrations to illustrate different phenomena when teaching of nuclear physics. Realizing this situation the authors have published, since 1970, reports on several experiments for teaching demonstrations. Based on the authors instructions, a factory in Hungary (TANFRT, National Manufacturers and Suppliers of School Equipment, Budapest) constructed a kit for the use of nuclear track detectors in teaching. The portable kit contains the following items: alpha-emitting weak sources, solid state nuclear track detectors (unirradiated, irradiated, unetched and etched sheets), simple tools for carrying out experiments (facilities for irradiation and etching, etc.), slides showing photos of typical etch-tracks of light and heavy nuclei, user manual. By the help of the kit both pupils and teachers can perform various useful experiments and/or demonstrations. (author)

  15. Monopole track characteristics in plastic detectors

    Science.gov (United States)

    Ahlen, S. P.

    1975-01-01

    Total and restricted energy loss rates were calculated for magnetic monopoles of charge g = 137 e in Lexan polycarbonate. Range-energy curves are also presented. The restricted energy loss model is used to estimate the appearance of a monopole track in plastic detectors. These results should be useful for the design and analysis of monopole experiments.

  16. Comparison of different PADC materials and etching conditions for fast neutron dosimetry

    International Nuclear Information System (INIS)

    Assenmacher, F.; Boschung, M.; Hohmann, E.; Mayer, S.

    2016-01-01

    Etched-track polyallyl diglycol carbonate (PADC) dosemeters have been in use at the Paul Scherrer Institute since 1998 in neutron dosimetry for individual monitoring. In the last years, the availability of PADC materials from different manufacturers has grown, and different etching conditions were proposed, with the intention to improve the quality and overall performance of PADC in individual neutron monitoring. The goal of the present study was to compare the performance of different PADC materials and to investigate the influence of different etching conditions on sensitivity to fast neutrons and lower detection limit. The comparison covers six different PADC materials and eight different etching conditions. (authors)

  17. A parameterization of nuclear track profiles in CR-39 detector

    Science.gov (United States)

    Azooz, A. A.; Al-Nia'emi, S. H.; Al-Jubbori, M. A.

    2012-11-01

    In this work, the empirical parameterization describing the alpha particles’ track depth in CR-39 detectors is extended to describe longitudinal track profiles against etching time for protons and alpha particles. MATLAB based software is developed for this purpose. The software calculates and plots the depth, diameter, range, residual range, saturation time, and etch rate versus etching time. The software predictions are compared with other experimental data and with results of calculations using the original software, TRACK_TEST, developed for alpha track calculations. The software related to this work is freely downloadable and performs calculations for protons in addition to alpha particles. Program summary Program title: CR39 Catalog identifier: AENA_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AENA_v1_0.html Program obtainable from: CPC Program Library, Queen’s University, Belfast, N. Ireland Licensing provisions: Copyright (c) 2011, Aasim Azooz Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met • Redistributions of source code must retain the above copyright, this list of conditions and the following disclaimer. • Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution This software is provided by the copyright holders and contributors “as is” and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. In no event shall the copyright owner or contributors be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data, or profits; or business interruption) however caused and

  18. Artificial ion tracks in volcanic dark mica simulating natural radiation damage: A scanning force microscopy study

    International Nuclear Information System (INIS)

    Lang, M.; Glasmacher, U.A.; Moine, B.; Mueller, C.; Neumann, R.; Wagner, G.A.

    2002-01-01

    A new dating technique uses alpha-recoil tracks (ART), formed by the natural α-decay of U, Th and their daughter products, to determine the formation age of Quaternary volcanic rocks ( 6 a). Visualization of etched ART by scanning force microscopy (SFM) enables to access track densities beyond 10 8 cm -2 and thus extend the new ART-dating technique to an age range >10 6 a. In order to simulate natural radiation damage, samples of phlogopite, originating from Quaternary and Tertiary volcanic rocks of the Eifel (Germany) and Kerguelen Islands (Indian Ocean) were irradiated with U, Ni (11.4 MeV/u), Xe, Cr, Ne (1.4 MeV/u) and Bi (200 keV) ions. After irradiation and etching with HF at various etching times, phlogopite surfaces were visualized by SFM. Hexagonal etch pits are typical of U, Xe and Cr ion tracks, but the etch pits of Ni, Ne and Bi ion tracks are triangular. Surfaces irradiated with U, Xe, Cr and Ni ions do not show any significant difference between etch pit density and irradiation fluence, whereas the Ne-irradiated surface show ∼14 times less etch pit density. The etching rate v H (parallel to cleavage) depends on the chemical composition of the phlogopite. The etching rate v T ' (along the track) increases with energy loss

  19. Impact of electron irradiation on particle track etching response in ...

    Indian Academy of Sciences (India)

    energy by an ionizing particle traversing a material medium. When the ... Their amorphous nature and radiation sensitivity further ... The samples were washed thoroughly in lukewarm soap solution to avoid non-uniformity in etching due to ...

  20. Characterization and Processing Behavior of Heated Aluminum-Polycarbonate Composite Build Plates for the FDM Additive Manufacturing Process

    Directory of Open Access Journals (Sweden)

    Sherri L. Messimer

    2018-02-01

    Full Text Available One of the most essential components of the fused deposition modeling (FDM additive manufacturing (AM process is the build plate, the surface upon which the part is constructed. These are typically made from aluminum or glass, but there are clear disadvantages to both and restrictions on which materials can be processed on them successfully. This study examined the suitability of heated aluminum-polycarbonate (AL-PC composite print beds for FDM, looking particularly at the mechanical properties, thermal behavior, deformation behavior, bonding strength with deposited material, printing quality, and range of material usability. Theoretical examination and physical experiments were performed for each of these areas; the results were compared to similar experiments done using heated aluminum and aluminum-glass print beds. Ten distinct materials (ABS, PLA, PET, HIPS, PC, TPU, PVA, nylon, metal PLA, and carbon-fiber PLA were tested for printing performance. The use of a heated AL-PC print bed was found to be a practical option for most of the materials, particularly ABS and TPU, which are often challenging to process using traditional print bed types. Generally, the results were found to be equivalent to or superior to tempered glass and superior to standard aluminum build plates in terms of printing capability.

  1. Low-level radon measurements by nuclear track detectors

    International Nuclear Information System (INIS)

    Koksal, E. M.; Goksel, S. A.; Alkan, H.

    1985-01-01

    In the work to be described here we have developed a passive nuclear track dosimeter to measure the integrated value of indoor radon (Rn-222) over a long period of time. Passive radon dosimeter which we have developed in our laboratories makes use of two small pieces of CR-39 plastic (Allyl diglycol carbonate) as detectors for registering tracks of alpha particles emitted by radon. These CR-39 plastic detectors are fixed on the inside bottom of a cup-shaped polystrene enclosure which is closed at the top by a tissue permeable for gases only. CR-39 detectors exposed to radon gas in the indoor air for a period of six months then are removed and chemically etched to make the alpha particle tracks visible under the microscope. The counts of tracks are evaluated to determine the radon concentration in the air in comparison with the number of tracks produced by a known concentration of radon gas. By using the passive dosimeters developed and the chemical etching procedure descriped here, measurements of indoor radon concentrations were carried out in 45 houses in different districts of the city of Istanbul. In this pilot experiment mean radon concentrations between 0.7 and 3.5 pCi/l have been found in these houses. In order to improve the counting of alpha tracks produced on the detectors a prototype electrochemical etching system in addition to chemical etching, is being developed. (author)

  2. Photodegradation of bisphenol A polycarbonate

    NARCIS (Netherlands)

    Diepens, M.; Gijsman, P.

    2007-01-01

    When bisphenol A polycarbonate is subjected to weathering conditions this polymer shows two different degradation mechanisms depending on the used irradiation wavelengths, i.e. photo-oxidation and photo-Fries rearrangement. The relative importance of these mechanisms in outdoor exposure conditions

  3. A novel process for separation of polycarbonate, polyvinyl chloride and polymethyl methacrylate waste plastics by froth flotation.

    Science.gov (United States)

    Wang, Chong-Qing; Wang, Hui; Huang, Luo-Luo

    2017-07-01

    A novel process was proposed for separation of ternary waste plastics by froth flotation. Pretreatment of plastics with potassium permanganate (KMnO 4 ) solution was conducted to aid flotation separation of polycarbonate (PC), polyvinyl chloride (PVC) and polymethyl methacrylate (PMMA) plastics. The effect of pretreatment parameters including KMnO 4 concentration, treatment time, temperature and stirring rate on flotation recovery were investigated by single factor experiments. Surface treatment with KMnO 4 changes selectively the flotation behavior of PC, PVC and PMMA, enabling separation of the plastics by froth flotation. Mechanism of surface treatment was studied by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray photoelectron spectrum (XPS). Effect of frother concentration and flotation time on flotation behavior of plastic mixtures was further studied for flotation separation. The optimized conditions for separation of PC are KMnO 4 concentration 2mmolL -1 , treatment time 10min, temperature 60°C, stirring rate 300rpm, flotation time 1min and frother concentration 17.5mgL -1 . Under optimum conditions, PVC and PMMA mixtures are also separated efficiently by froth flotation associated with KMnO 4 treatment. The purity of PC, PVC and PMMA is up to 100%, 98.41% and 98.68%, while the recovery reaches 96.82%, 98.71% and 98.38%, respectively. Economic analysis manifests remarkable profits of the developed process. Reusing KMnO 4 solution is feasible, enabling the process greener. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Investigation on Nano composite Membrane of Multi walled Carbon Nano tube Reinforced Polycarbonate Blend for Gas Separation

    International Nuclear Information System (INIS)

    Kausar, A.

    2016-01-01

    Carbon nano tube has been explored as a nano filler in high performance polymeric membrane for gas separation. In this regard, nano composite membrane of polycarbonate (PC), poly(vinylidene fluoride-co-hexafluoropropylene) (PVFHFP), and multi walled carbon nano tube (MWCNT) was fabricated via phase inversion technique. Poly (ethylene glycol) (PEG) was employed for the compatibilization of the blend system. Two series of PC/PVFHFP/PEG were developed using purified P-MWCNT and acid functional A-MWCNT nano filler. Scanning and transmission electron micrographs have shown fine nano tube dispersion and wetting by matrix, compared with the purified system. Tensile strength and Young s modulus of PC/PVFHFP/PEG/MWCNT-A 1-5 were found to be in the range of 63.6-72.5 MPa and 110.6-122.1 MPa, respectively. The nano composite revealed 51% increase in Young s modulus and 28% increase in tensile stress relative to the pristine blend. The A-MWCNT was also effective in enhancing the perm selectivity αCO 2 /N 2 (31.2-39.9) of nano composite membrane relative to the blend membrane (21.6). The permeability ρCO 2 of blend was 125.6 barrer; however, the functional series had enhancedρCO 2 values ranging from 142.8 to 186.6 barrer. Moreover, A-MWCNT loading improved the gas diffusivity of PC/PVFHFP/PEG/MWCNT-A 1-5; however, filler content did not significantly influence the CO 2 and N 2 solubility.

  5. Etched-hole formation in LR-115 cellulose nitrate detector irradiated with fast neutrons

    International Nuclear Information System (INIS)

    Sawamura, Teruko; Yamazaki, Hatsuo

    1988-01-01

    This paper deals with the neutron detection sensitivity of LR-115 cellulose nitrate by counting the etched holes of α-tracks produced by the (n,α) reactions of the constituent nuclei of the cellulose nitrate. A formula for the etched-hole formation efficiency is derived, and applied to obtain the efficiency for each of the (n,α) reactions of 14 N, 16 O and 12 C by using an experimental expression relating the track-to-bulk etch-rate ratio to the residual range of the α-particle. From the efficiencies obtained, and the reaction cross sections, the neutron detection sensitivity is evaluated against neutron energy up to 11 MeV, and compared with the experimental values in the energy region between 2.2 and 5 MeV; the agreement is fairly good in the region. (author)

  6. Single charged-particle damage to living cells: a new method based on track-etch detectors

    International Nuclear Information System (INIS)

    Durante, M.; Grossi, G.F.; Pugliese, M.; Manti, L.; Nappo, M.; Gialanella, G.

    1994-01-01

    Biological effects of ionizing radiation are usually expressed as a function of the absorbed dose. Low doses of high-LET radiation correspond to one or few particle traversals through the cell. In order to study the biological effectiveness of single charged particles, we have developed a new method based on solid state nuclear track detectors. Cells are seeded on mylar and a LR-115 film is stuck below the mylar base. After irradiation, the LR-115 film is etched and cells observed at a phase contrast microscope connected to a video camera and an image analyzer. In this way, it is possible to measure the number of traversals through the cell nucleus or cytoplasm. Coordinates of each cell on the microscope bench are saved. After incubation for about one week, cells are fixed and stained and the colonies observed at the microscope. The fate of each irradiated cell is therefore correlated to the number of traversals. We have tested this method with two different rodent embryo fibroblast cell lines, C3H 10T1/2 and V79, exposed to 3.2 MeV accelerated α-particles (LET =124 keV/μm). The studied endpoint was cell killing. Preliminary biological results suggest that few α-particle tracks in V79 hamster cells are sufficient to reduce surviving fraction. ((orig.))

  7. Etching behavior of poly (vinylidene fluoride) thin films irradiated with ion beams. Effect of irradiated ions and pretreatment

    International Nuclear Information System (INIS)

    Yamaki, Tetsuya; Rohani, Rosiah; Koshikawa, Hiroshi; Takahashi, Shuichi; Hasegawa, Shin; Asano, Masaharu; Maekawa, Yasunari; Voss, Kay-Obbe; Neumann, Reinhard

    2008-01-01

    Poly (vinylidene fluoride) thin films irradiated with four kinds of ion beams were exposed to a 9M KOH aqueous solution after their storage in air for 30 or 90 days at different temperatures. According to the conductometry, the heating at 120degC was found to enhance the etch rate in the latent track without changing that in the bulk, thereby enabling us to obtain very high etching sensitivity for the preparation of nano-sized through-pores. The formation of hydroperoxides during this pretreatment should facilitate the introduction of the etching agent to improve etchability. Additionally, the irradiation of higher-LET ions, causing each track to contain more activated sites (like radicals), was preferable to achieve high sensitivity of the etching. (author)

  8. Morphology, Nucleation, and Isothermal Crystallization Kinetics of Poly(ε-caprolactone Mixed with a Polycarbonate/MWCNTs Masterbatch

    Directory of Open Access Journals (Sweden)

    Thandi P. Gumede

    2017-12-01

    Full Text Available In this study, nanocomposites were prepared by melt blending poly (ε-caprolactone (PCL with a (polycarbonate (PC/multi-wall carbon nanotubes (MWCNTs masterbatch in a twin-screw extruder. The nanocomposites contained 0.5, 1.0, 2.0, and 4.0 wt % MWCNTs. Even though PCL and PC have been reported to be miscible, our DSC (Differential Scanning Calorimetry, SAXS (Small Angle X-ray Scattering, and WAXS (Wide Angle X-ray Scattering results showed partial miscibility, where two phases were formed (PC-rich and PCL-rich phases. In the PC-rich phase, the small amount of PCL chains included within this phase plasticized the PC component and the PC-rich phase was therefore able to crystallize. In contrast, in the PCL-rich phase the amount of PC chains present generates changes in the glass transition temperature of the PCL phase that were much smaller than those predicted by the Fox equation. The presence of two phases was corroborated by SEM, TEM, and AFM observations where a fair number of MWCNTs diffused from the PC-rich phase to the PCL-rich phase, even though there were some MWCNTs agglomerates confined to PC-rich droplets. Standard DSC measurements demonstrated that the MWCNTs nucleation effects are saturated at a 1 wt % MWCNT concentration on the PCL-rich phase. This is consistent with the dielectric percolation threshold, which was found to be between 0.5 and 1 wt % MWCNTs. However, the nucleating efficiency was lower than literature reports for PCL/MWCNTs, due to limited phase mixing between the PC-rich and the PCL-rich phases. Isothermal crystallization experiments performed by DSC showed an increase in the overall crystallization kinetics of PCL with increases in MWCNTs as a result of their nucleating effect. Nevertheless, the crystallinity degree of the nanocomposite containing 4 wt % MWCNTs decreased by about 15% in comparison to neat PCL. This was attributed to the presence of the PC-rich phase, which was able to crystallize in view of the

  9. Spark counting technique with an aluminium oxide film

    International Nuclear Information System (INIS)

    Kawai, H.; Koga, T.; Morishima, H.; Niwa, T.; Nishiwaki, Y.

    1980-01-01

    Automatic spark counting of etch-pits on a polycarbonate film produced by nuclear fission fragments is now used for neutron monitoring in several countries. A method was developed using an aluminium oxide film instead of a polycarbonate as the neutron detector. Aluminium oxide films were prepared as follows: A cleaned aluminium plate as an anode and a nickel plate as a cathode were immersed in dilute sulfuric acid solution and electric current flowed between the electrodes at 12degC for 10-30 minutes. Electric current density was about 10 mA/cm 2 . The aluminium plate was then kept in boiling water for 10-30 minutes for sealing. The thickness of the aluminium oxide layer formed was about 1μm. The aluminium plate attached to a plate of suitable fissionable material, such as uranium or thorium, was irradiated with neutrons and set in a usual spark counter for fission track counting. One electrode was the aluminium plate and the other was an aluminized polyester sheet. Sparked pulses were counted with a usual scaler. The advantage of using spark counting with an aluminium oxide film for neutron monitoring is rapid measurement of neutron exposure, since chemical etching which is indispensable for spark counting with a polycarbonate detector film, is not needed. (H.K.)

  10. Some characteristics of the Atomic Energy Organization of Iran (AEOI) passive radon diffusion dosimeter for indoor exposure determination of public in Iran

    International Nuclear Information System (INIS)

    Sohrabi, M.; Solaymanian, A.R.

    1989-01-01

    A Passive Radon diffusion dosimeter (PRDD) was developed at the Radiation Protection Department of the Atomic Energy Organization of Iran (AEOI) for large scale radon level measurements in Iran. It consists of a plastic cup with a polycarbonate alpha detector in the middle, a plastic top cover with an opening holding a fiberglass filter and a hard aluminium mesh for protection and support. A new design of our multi-chamber system was used for multiple foil etching. The effects of pre-etching and ECE times, chamber volume, filter diameter and foil position inside the chamber were investigated. The optimized geometries include 9.5 cm height, 269 cm 3 volume and 2-3 cm filter diameter with the polycarbonate foil mounted in the middle. A sensitivity of 0.05+-0.007 tracks cm -2 /Bq.m -3 day or 1.96+-0.28 tracks cm -2 /pCi.1 -1 day was obtained at optimized conditions. The characteristics of the dosimeter as well as some preliminary results of indoor radon level measurements for determination of public exposure in 250 houses in different cities of Iran including Tehran, Ramsar, Babolsar and Gonabad are presented. The highest radon levels were found in high natural areas of Ramsar

  11. Calibration of the polycarbonate dosimeter for the microdosimetry of 239Pu alpha particles in bone

    International Nuclear Information System (INIS)

    Stillwagon, G.B.; Morgan, K.Z.

    1977-01-01

    There has been some criticisms of the maximum permissible organ burden (MPOB) in bone for 239 Pu in recent years. These criticisms allude to the relative dearth of experimental data available concerning the actual dose delivered to the endosteal face of osseous tissue by the 239 Pu alpha particle. A dosimeter recently developed has been recommended for application to this microdosimetry problem. The tissue equivalence of polycarbonate dosimeters would allow dose equivalent to be read directly from the foil rather than determining activity from emulsions, in which the alpha particle range is different than in tissue, then relating this activity measurement to absorbed dose by some calculations. Although this dosimeter has been calibrated to read dose equivalent for fast neutron dosimetry, the need exists to determine the factor to multiply by the number of 239 Pu alpha-induced tracks to obtain dose equivalent. This problem is being approached in the following manner. A device called the vacuum-sealed alpha-calibrator has been designed and constructed which will allow the handling of a standard 239 Pu solution obtained for this purpose. The calibrator will first be connected to surface barrier detectors which feed data into a multi-channel analyzer. The counts obtained under the alpha peaks at various heights above the source and the accumulated time are input into a computer program recently written to convert this data into dose rate in rems/unit time. Next the measurements are duplicated, this time using the polycarbonate dosimeter. The results will produce a factor relating the number of alpha-induced tracks to dose

  12. Calibration of Nuclear Track Detectors

    International Nuclear Information System (INIS)

    Vukovic, J.B; Antanasijevic, R.; Novakovic, V.; Tasic, M.

    1998-01-01

    In this work we compare some of our preliminary results relating to the calibration Nuclear Track Detectors (NTD) with corresponding results obtained from other participants at the First International Intercomparison of Image Analyzers (III 97/98). Thirteen laboratories from Algeria, China, Czech Rep., France. Germany, Greece, Hungary, India, Italy, Mexico, Saudi Arabia, Slovenia and Yugoslavia participated in the III A 97/98. The NTD was 'Tustrack', Bristol. This type of CR-39 detector was etched by the organizer (J.Paltarey of al, Atomic Energy Research Institute, HPD, Budapest, Hungary). Etching condition was: 6N NaOH, 70 0C . Seven series detectors were exposed with the sources: B(n,a)Li, Am-241, Pu-Be(n,p), Radon and Am-Cm-Pu. Following parameters of exposed detectors were measured: track density of different sorts of tracks (circular, elliptical, track overlapping, their diameters, major and minor axis and other). (authors)

  13. Acid-catalyzed kinetics of indium tin oxide etching

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jae-Hyeok; Kim, Seong-Oh; Hilton, Diana L. [School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore); Centre for Biomimetic Sensor Science, Nanyang Technological University, 50 Nanyang Drive, 637553 (Singapore); Cho, Nam-Joon, E-mail: njcho@ntu.edu.sg [School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, 639798 (Singapore); Centre for Biomimetic Sensor Science, Nanyang Technological University, 50 Nanyang Drive, 637553 (Singapore); School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, 637459 (Singapore)

    2014-08-28

    We report the kinetic characterization of indium tin oxide (ITO) film etching by chemical treatment in acidic and basic electrolytes. It was observed that film etching increased under more acidic conditions, whereas basic conditions led to minimal etching on the time scale of the experiments. Quartz crystal microbalance was employed in order to track the reaction kinetics as a function of the concentration of hydrochloric acid and accordingly solution pH. Contact angle measurements and atomic force microscopy experiments determined that acid treatment increases surface hydrophilicity and porosity. X-ray photoelectron spectroscopy experiments identified that film etching is primarily caused by dissolution of indium species. A kinetic model was developed to explain the acid-catalyzed dissolution of ITO surfaces, and showed a logarithmic relationship between the rate of dissolution and the concentration of undisassociated hydrochloric acid molecules. Taken together, the findings presented in this work verify the acid-catalyzed kinetics of ITO film dissolution by chemical treatment, and support that the corresponding chemical reactions should be accounted for in ITO film processing applications. - Highlights: • Acidic conditions promoted indium tin oxide (ITO) film etching via dissolution. • Logarithm of the dissolution rate depended linearly on the solution pH. • Acid treatment increased ITO surface hydrophilicity and porosity. • ITO film etching led to preferential dissolution of indium species over tin species.

  14. Fast neutron dosimetry using CR-39 track detectors with polyethylene as radiator

    International Nuclear Information System (INIS)

    Castillo, F.; Espinosa, G.; Golzarri, J.I.; Osorio, D.; Rangel, J.; Reyes, P.G.; Herrera, J.J.E.

    2013-01-01

    The chemical etching parameters (etching time, temperature, normality of etchant, etc.) for the use of CR-39 (allyl diglycol carbonate – Lantrack ® ) as a fast neutron dosimeter have been optimized. The CR-39 chips, placed under a 1.5 mm polyethylene radiator, were exposed for calibration to an 241 Am-Be source at different time intervals for a given neutron fluence. After several chemical etching processes of the detectors with different conditions, the optimum characteristics for the chemical etching were found at 6N KOH solution, 60 ± 1 °C, for 12 h. An accurate relationship between the dose and fluence calculations was obtained as a function of the track density. - Highlights: ► Optimum etching time for fast neutron irradiated CR-39 track detectors is found. ► Relationship between dose and fluence obtained as a function of the track density. ► Results are consistent with those reported elsewhere, and extend the dose range

  15. A Universal Platform for Identification of Novel Lung Cancer Biomarkers Based on Exosomes

    Science.gov (United States)

    2017-10-01

    plastic layers, a polycarbonate track-etched nanoporous filter membrane, polyethersulfone (PES) layer, and cellulose pad. The plastic housing is...secured with metal screws and nuts and a plastic ring-shaped gasket provides a leak-free seal. The cellulose pad prevents deformation of the filter...Figure 3c). The forty most highly expressed microRNAs were common (100% overlap) to both EV isolation methods. The Venn diagram in Figure 3d for two

  16. Longitudinally Controlled Modification of Cylindrical and Conical Track-Etched Poly(ethylene terephthalate) Pores Using an Electrochemically Assisted Click Reaction

    International Nuclear Information System (INIS)

    Coceancigh, Herman; Tran-Ba, Khanh-Hoa; Columbia University, New York, NY; Siepser, Natasha; Baker, Lane A.; Ito, Takashi

    2017-01-01

    Here in this study, the longitudinally controlled modification of the inner surfaces of poly(ethylene terephthalate) (PET) track-etched pores was explored using an electrochemically assisted Cu(I)-catalyzed azide–alkyne cycloaddition (CuAAC) click reaction. Cylindrical or conical PET track-etched pores were first decorated with ethynyl groups via the amidation of surface -COOH groups, filled with a solution containing Cu(II) and azide-tagged fluorescent dye, and then sandwiched between comb-shaped and planar gold electrodes. Cu(I) was produced at the comb-shaped working electrode by the reduction of Cu(II); it diffused along the pores toward the other electrode and catalyzed CuAAC between an azide-tagged fluorescent dye and a pore-tethered ethynyl group. The modification efficiency of cylindrical pores (ca. 1 μm in diameter) was assessed from planar and cross-sectional fluorescence microscope images of modified membranes. Planar images showed that pore modification took place only above the teeth of the comb-shaped electrode with a higher reaction yield for longer Cu(II) reduction times. Cross-sectional images revealed micrometer-scale gradient modification along the pore axis, which reflected a Cu(I) concentration profile within the pores, as supported by finite-element computer simulations. The reported approach was applicable to the asymmetric modification of cylindrical pores with two different fluorescent dyes in the opposite directions and also for the selective visualization of the tip and base openings of conical pores (ca. 3.5 μm in base diameter and ca. 1 μm in tip diameter). Lastly, the method based on electrochemically assisted CuAAC provides a controlled means to fabricate asymmetrically modified nanoporous membranes and, in the future, will be applicable for chemical separations and the development of sequential catalytic reactors.

  17. Personal neutron dosimeter using solid-state track detector

    International Nuclear Information System (INIS)

    Mettripan, S.

    1980-01-01

    A cellulose nitrate film coated on both sides with lithium tetraborate was used as a neutron dosimeter for surveillance of personnel exposed to thermal and epithermal neutron. It was found that the optimum etching conditions used were 10% solution of sodium hydroxide, 60 degrees C and 20 minutes etching time and the alpha track densities from the (n,α) reaction on the films were proportional to thermal and epithermal neutron fluxes. The response of the film was found to be 1.068 x 10 -3 tracks per thermal neutron and 3.438 x 10 -4 tracks per epithermal neutron

  18. Metal-assisted etch combined with regularizing etch

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Joanne; Miller, Jeff; Jura, Michael; Black, Marcie R.; Forziati, Joanne; Murphy, Brian; Magliozzi, Lauren

    2018-03-06

    In an aspect of the disclosure, a process for forming nanostructuring on a silicon-containing substrate is provided. The process comprises (a) performing metal-assisted chemical etching on the substrate, (b) performing a clean, including partial or total removal of the metal used to assist the chemical etch, and (c) performing an isotropic or substantially isotropic chemical etch subsequently to the metal-assisted chemical etch of step (a). In an alternative aspect of the disclosure, the process comprises (a) performing metal-assisted chemical etching on the substrate, (b) cleaning the substrate, including removal of some or all of the assisting metal, and (c) performing a chemical etch which results in regularized openings in the silicon substrate.

  19. Track sensitivity and the surface roughness measurements of CR-39 with atomic force microscope

    CERN Document Server

    Yasuda, N; Amemiya, K; Takahashi, H; Kyan, A; Ogura, K

    1999-01-01

    Atomic Force Microscope (AFM) has been applied to evaluate the surface roughness and the track sensitivity of CR-39 track detector. We experimentally confirmed the inverse correlation between the track sensitivity and the roughness of the detector surface after etching. The surface of CR-39 (CR-39 doped with antioxidant (HARZLAS (TD-1)) and copolymer of CR-39/NIPAAm (TNF-1)) with high sensitivity becomes rough by the etching, while the pure CR-39 (BARYOTRAK) with low sensitivity keeps its original surface clarity even for the long etching.

  20. Novel routes in flame retardancy of bisphenol A polycarbonate/impact modifier/aryl phosphate blends

    Energy Technology Data Exchange (ETDEWEB)

    Wawrzyn, Eliza

    2013-07-01

    The massive use of electronic engineering products accompanied by high demands on fire safety has led to increasing interest in environmentally friendly flame retardancy of bisphenol A polycarbonate (PC) based materials. In this work, novel routes for enhancing the flame retardancy of PC/Impact Modifier/Aryl phosphate were studied with respect to pyrolysis (TG, TG-FTIR, ATR-FTIR, NMR), flammability (LOI and UL 94) and fire behavior (cone calorimeter at different irradiations). To improve charring of PC/ABS{sub PTFE}+Aryl phosphate, the exchange of bisphenol A bis(diphenyl phosphate) (BDP) with novel aryl phosphates was proposed. Two novel flame retardants were synthesized: 3,3,5-trimethylcyclohexylbisphenol-bis(diphenyl phosphate) (TMC-BDP) and bisphenol A-bis(diethylphosphate) (BEP). TMC-BDP was more stable than BDP, thus gave a potential to increase the chemical reactions between the components of the PC/ABS{sub PTFE}+Aryl phosphate, whereas more reactive BEP was expected to increase the cross linking activity with the polymer matrix. Nevertheless, the corresponding blends did not enhance the flame retardancy compared to PC/ABS{sub PTFE}+BDP. BEP in PC/ABS{sub PTFE} preferred to cross-link with itself instead of with PC, thus it showed poor fire protection performance. TMC-BDP gave as good results as BDP in PC/ABS PTFE material. The results delivered evidence that BDP possesses a high degree of optimization in PC/ABS{sub PTFE} system. To provide a novel impact modifier improving not only mechanical properties but also the fire retardancy of PC/BDP material, the replacement of highly flammable acrylonitrile-butadiene-styrene (ABS) with silicon acrylate rubber (SiR) with high content of polydimethylsiloxane (PDMS) was studied. In PC/SiR{sub PTFE}/BDP the replacement of ABS is beneficial, but PDMS worsened the BDP gas phase and condensed phase action. PDMS reacted also with PC during combustion. PDMS-PC and PDMS-BDP interactions led to silicon dioxide. In fact, the

  1. Activation energy of etching for CR-39 as a function of linear energy transfer of the incident particles

    CERN Document Server

    Awad, E M

    1999-01-01

    In this work, we have studied the effect of the radiation damage caused by the incident particles on the activation energy of etching for CR-39 samples. The damage produced by the incident particle is expressed in terms of the linear energy transfer (LET). CR-39 samples from American Acrylic were irradiated to three different LET particles. These are N (LET sub 2 sub 0 sub 0 = 20 KeV/mu m) as a light particle, Fe (LET sub 2 sub 0 sub 0 = 110 KeV/mu m) as a medium particle and fission fragments (ff) from a sup 2 sup 5 sup 2 Cf source as heavy particles. In general the bulk etch rate was calculated using the weight difference method and the track etch rate was determined using the track geometry at various temperatures (50-90 deg. C) and concentrations (4-9 N) of the NaOH etchant. The average activation energy E sub b related to the bulk etch rate v sub b was calculated from 1n v sub b vs. 1/T. The average activation energy E sub t related to the track etch rate v sub t was estimated from 1n v sub t vs. 1/T. It...

  2. Effects of gamma-rays irradiation on tracking resistance of organic insulating materials

    Energy Technology Data Exchange (ETDEWEB)

    Du, Boxue; Suzuki, Akio; Kobayashi, Shigeo [Tokyo Univ. of Agriculture and Technology, Koganei (Japan). Faculty of Technology

    1996-04-01

    This paper describes the influence of gamma-rays irradiation on tracking failure of organic insulating materials by use of the IEC Publ.112 method. Tracking resistance of organic insulating materials under wet polluted condition has been studied by many investigators with a test method of the IEC Publ.112. The investigations on irradiation effects on tracking resistance should be enhanced due to the increasing usage of organic insulating materials in the radiation environments. The tracking resistance seems to be affected by gamma-irradiation, but the knowledge on the influence of gamma-irradiation is quite a few and systematic studies are needed. In this paper, modified polyphenylene oxide, polybutylene naphthalate, modified polycarbonate and polybutylene terephthalate which were irradiated in air until 1x10{sup 7}R and 1x10{sup 8}R with dose rate of 10{sup 6}R/hr using {sup 60}Co gamma-source have been employed. The total dose effects on the number of drops to tracking failure, contact angle and charges of scintillation have been studied. As the total doses are increased, the number of drops to tracking failure decreases with polybutylene terephthalate. On the other hand, the number of drops to tracking failure increases with polybutylene naphthalate and modified polycarbonate when the total doses are increased. The effects of gamma-rays irradiation on tracking failure are due to radiation-induced degradation or cross-linking of organic insulating materials. When the organic insulating materials are degraded by gamma-irradiation, the tracking resistance decreases, but for cross-linking type materials, the tracking resistance increases. (author)

  3. Discovery of an 'internal heating effect' during electrochemical etching of polymeric dosimeters: a study of polymer characteristics

    International Nuclear Information System (INIS)

    Sohrabi, M.

    1986-01-01

    This paper investigates the importance of the internal heating effect by studying the role of different polymer physical and chemical characteristics (composition, effective foil size, thickness and electrical properties), on the rate of heating or temperature rise responses for cellulose tri-acetate (CTA), cellulose acetate (CA), allyl diglycol carbonate (CR-39), cellulose nitrate (CN), cellulose acetate butyrate (CAB), polyester (PES), polycarbonate (PC) and polyethylene (PE). Efforts have been made to justify the observed effects by different mechanisms such as dielectric loss, electro-osmosis, dielectrophoresis, and electrostriction. (author)

  4. Latent track structure in polymers as observed by a highly sensitive electrolytical conductivity measurement

    International Nuclear Information System (INIS)

    Danziger, M.; Schulz, A.; Trofimov, V.V.; Prokert, K.

    1994-01-01

    First results of a new electrolytical conductivity cell are reported concerning the initial stage of the pore opening process during track etching in vitreous solids. On the basis of the soft mode (low energy excitation) model for track etching, a distribution function for the number of performed micropores as function of time is calculated. The results account for the radial etch rate as function of the effective pore radius. ((orig.))

  5. Investigation of excimer laser ablation threshold of polymers using a microphone

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, Joerg; Niino, Hiroyuki; Yabe, Akira

    2002-09-30

    KrF excimer laser ablation of polyethylene terephthalate (PET), polyimide (PI) and polycarbonate (PC) in air was studied by an in situ monitoring technique using a microphone. The microphone signal generated by a short acoustic pulse represented the etch rate of laser ablation depending on the laser fluence, i.e., the ablation 'strength'. From a linear relationship between the microphone output voltage and the laser fluence, the single-pulse ablation thresholds were found to be 30 mJ cm{sup -2} for PET, 37 mJ cm{sup -2} for PI and 51 mJ cm{sup -2} for PC (20-pulses threshold). The ablation thresholds of PET and PI were not influenced by the number of pulses per spot, while PC showed an incubation phenomenon. A microphone technique provides a simple method to determine the excimer laser ablation threshold of polymer films.

  6. Modifications of radiation detection response of PADC track detectors by photons

    CERN Document Server

    Sinha, D

    1998-01-01

    Photon induced modifications in polyalyldiglycol carbonate (PADC) track detectors have been studied in the dose range of 10 sup 1 -10 sup 6 Gy. It was found that some of the properties like bulk-etch rate, track-etch rate got enhanced at the dose of 10 sup 6 Gy. Activation energy for bulk-etching has been determined for different gamma doses. In order to correlate the high etch rate with the chemical modifications, UV-Vis, IR and ESR studies were carried out. These studies clearly give the indication that radiation damage results into radical formation through bond cleavage. TGA study was performed for understanding the thermal resistance of this detector. The results are presented and discussed.

  7. DLC-Si protective coatings for polycarbonates

    Directory of Open Access Journals (Sweden)

    Damasceno J.C.

    2003-01-01

    Full Text Available In this work, a-C:H:Si (DLC-Si films were produced onto crystalline silicon and polycarbonate substrates by the rf-PACVD technique from gaseous mixtures of CH4 + SiH4 and C2H2 + SiH4. The effects of self-bias and gas composition upon mechanical and optical properties of the films were investigated. Micro-hardness, residual stress, surface roughness and refractive index measurements were employed for characterization. By incorporating low concentrations of silicon and by exploring the more favorable conditions for the rf-PACVD deposition technique, highly adherent DLC-Si thin films were produced with reduced internal stresses (lower than 1 GPa, high hardness (around 20 GPa and high deposition rates (up to 10 µm/h. Results that show the technological viability of this material for application as protective coatings for polycarbonates are also discussed.

  8. Radiolytic degradation and stability of polycarbonate

    International Nuclear Information System (INIS)

    Araujo, E.S. de.

    1993-01-01

    The radiolytic stability of polycarbonate was studied using national commercial additives, employed in the photo and thermo-oxidative stabilization of polymers. Among several additives tested only two showed the efficiency to radiolytic protection: one quencher and one radical scavenger. It was derived a linear relation that provides by slope of the straight line the degree of degradation (scissions), G, and the factors of radiolytic protection P (degree of protection) and CE (capture of energy) conferred by radioprotector additive easily. Therefore the method developed in this work (viscosity) to study the molecular degradation and stability of polymers is a simply and precise method. The synergic mixture of two additives (1% of weight total) confers at polycarbonate excellent radiolytic protection of 98% (20 - 40 kGy) reducing the G value of 16.7 to only 0.4. (author). 69 refs, 31 figs, 17 tabs

  9. Plastic nuclear track detectors as high x-ray and gamma dosimeters

    International Nuclear Information System (INIS)

    Chong Chon Sing

    1995-01-01

    A brief review of recent studies on the effects of high doses of x-ray and gamma ray on the track registration properties of several plastic track detectors is presented. The bulk etching rates and the etched track sizes have been found to increase with the dose in the range up to 100 Mrad. These results suggest that the changes in track registration characteristics can be employed as an index of the radiation dose in the megarad region. In particular, recent results on the effect of X-ray irradiation on two types of cellulose nitrate track detectors obtained in our laboratory are reported in this paper. (author)

  10. Image formation in track-etch detectors: Pt. 4

    International Nuclear Information System (INIS)

    Ilic, Radomir; Najzer, Mitja

    1990-01-01

    The radiographic performance of solid state nuclear track detectors was analysed with respect to image quality. Image quality is expressed in terms of three image quality factors: contrast or gradient of the detector, image unsharpness and detail discernment. Equations for the image quality factors were derived from the radiographic transfer function, taking into account image inhomogeneity caused by statistical fluctuations of track density. To find optimal radiographic conditions for a given application, a single quantity called the figure of radiographic merit was defined. It is expressed as the weighted product of the image quality factors. It was found that optimum image quality of a balanced image, characterized by equal importance of all three image quality factors, is obtained at an exposure value (defined as the product of the average visible track area and track density) of unity. (author)

  11. Bisphenol A is released from used polycarbonate animal cages into water at room temperature

    Science.gov (United States)

    Howdeshell, Kembra L.; Peterman, Paul H.; Judy, Barbara M.; Taylor, Julia A.; Orazio, Carl E.; Ruhlen, Rachel L.; vom Saal, Frederick S.; Welshons, Wade V.

    2003-01-01

    Bisphenol A (BPA) is a monomer with estrogenic activity that is used in the production of food packaging, dental sealants, polycarbonate plastic, and many other products. The monomer has previously been reported to hydrolyze and leach from these products under high heat and alkaline conditions, and the amount of leaching increases as a function of use. We examined whether new and used polycarbonate animal cages passively release bioactive levels of BPA into water at room temperature and neutral pH. Purified water was incubated at room temperature in new polycarbonate and polysulfone cages and used (discolored) polycarbonate cages, as well as control (glass and used polypropylene) containers. The resulting water samples were characterized with gas chromatography/mass spectrometry (GC/MS) and tested for estrogenic activity using an MCF-7 human breast cancer cell proliferation assay. Significant estrogenic activity, identifiable as BPA by GC/MS (up to 310 micro g/L), was released from used polycarbonate animal cages. Detectable levels of BPA were released from new polycarbonate cages (up to 0.3 micro g/L) as well as new polysulfone cages (1.5 micro g/L), whereas no BPA was detected in water incubated in glass and used polypropylene cages. Finally, BPA exposure as a result of being housed in used polycarbonate cages produced a 16% increase in uterine weight in prepubertal female mice relative to females housed in used polypropylene cages, although the difference was not statistically significant. Our findings suggest that laboratory animals maintained in polycarbonate and polysulfone cages are exposed to BPA via leaching, with exposure reaching the highest levels in old cages.

  12. Degradation study of Durolon polycarbonate submitted to gamma radiation

    International Nuclear Information System (INIS)

    Miranda, A.; Sciani, V.

    1992-01-01

    The effect of gamma radiation from a cobalt 60 source in the 27000 Durolon polycarbonate irradiated with doses between 0,2 and 1000 kGy at 25 0 C was analyzed. For this reason the samples was submitted to the mechanical assay of tension, deformation and hardness and optical assay of transmittance. The obtained results show a good mechanical stability of the polycarbonate, when it was submitted to gamma irradiation in doses up to 20 kGy. (C.G.C.). 05 refs., 04 figs

  13. Measuring depths of sub-micron tracks in a CR-39 detector from replicas using Atomic Force Microscopy

    International Nuclear Information System (INIS)

    Yu, K.N.; Ng, F.M.F.; Nikezic, D.

    2005-01-01

    One of the challenging tasks in the application of solid-state nuclear track detectors (SSNTDs) is the measurement of the depth of the tracks, in particular, the shallow ones resulting from short etching periods. In the present work, a method is proposed to prepare replicas of tracks from α particles in the CR-39 SSNTDs and to measure their heights using atomic force microscopy (AFM). After irradiation, the detectors were etched in a 6.25N aqueous solution of NaOH maintained at 70 deg. C. The etched detectors were immersed into a beaker of the replicating fluid, which was placed in a water bath under ultrasonic vibration and maintained at room temperature to facilitate the filling of the etched tracks with the replicating fluid. As an example of application, these results have been used to derive a V function for the CR-39 detectors used in the present study (for the specified etching conditions)

  14. Polycarbonate radiolytic degradation and stabilization

    International Nuclear Information System (INIS)

    Araujo, E.S. de

    1994-01-01

    Polycarbonate Durolon, useful for medical supplies fabrication, is submitted to gamma radiation for sterilization purposes. Scissions in main chain occur, in carbonyl groups, producing molecular degradations and yellowness. The radiolytic stabilization is obtained through additive to the polymer. In this work some degradation and stabilization aspects are presented. (L.C.J.A.). 7 refs, 7 figs, 2 tabs

  15. Preparation and characterization of Tb3+ and Tb(sal)3.nH2O doped PC:PMMA blend

    International Nuclear Information System (INIS)

    Dwivedi, Y.; Singh, A.K.; Prakash, Rajiv; Rai, S.B.

    2011-01-01

    Tb doped polycarbonate:poly(methyl methacrylate) (Tb-PC:PMMA) blend was prepared with varying proportions of PC and PMMA. Thermal and spectroscopic properties of the doped polymer have been investigated employing Fourier Transform Infrared (FTIR) absorption and differential scanning calorimetric (DSC) techniques. PC:PMMA blend (with 10 wt% PC and 90 wt% PMMA) shows better miscibility. Optical properties of the dopant Tb 3+ ions have been investigated using UV-vis absorption and fluorescence excited by 355 nm radiation. It is seen that luminescence intensity of Tb 3+ ion depends on PC:PMMA ratio and on Tb 3+ ion concentration. Concentration quenching is seen for TbCl 3 .6H 2 O concentration larger than 4 wt%. Addition of salicylic acid to the polymer blend increases the luminescence from Tb 3+ ions. Luminescence decay curve analysis affirms the non-radiative energy transfer from salicylic acid to Tb 3+ ions, which is identified as the reason behind this enhancement. - Highlights: → Blend formation is confirmed at PC/90PMMA, using FTIR and DSC techniques. → Absorption and bandgap studies of blend and parent components were studied. → Optical properties of Tb and Tb(sal) 3 .nH 2 O complex have been studied in PC/PMMA blend. → Luminescence decay curves confirm non-radiative energy transfer from Sal to Tb 3+ ions.

  16. Long-term measurements of equilibrium factor with electrochemically etched CR-39 SSNTD

    International Nuclear Information System (INIS)

    Ng, F.M.F.; Nikezic, D.; Yu, K.N.

    2007-01-01

    Recently, our group proposed a method (proxy equilibrium factor method) using a bare LR 115 detector for long-term monitoring of the equilibrium factor. Due to the presence of an upper alpha-particle energy threshold for track formation in the LR 115 detector, the partial sensitivities to 222 Rn, 218 Po and 214 Po were the same, which made possible measurements of a proxy equilibrium factor F p that was well correlated with the equilibrium factor. In the present work, the method is extended to CR-39 detectors which have better-controlled etching properties but do not have an upper energy threshold. An exposed bare CR-39 detector is first pre-etched in 6.25 N NaOH solution at 70 o C for 6 h, and then etched electrochemically in a 6.25 N NaOH solution with ac voltage of 400 V (peak to peak) and 5 kHz applied across the detectors for 1 h at room temperature. Under these conditions, for tracks corresponding to incident angles larger than or equal to 50 deg., the treeing efficiency is 0% and 100% for incident energies smaller than and larger than 4 MeV, respectively. A simple method is then proposed to obtain the total number of tracks formed below the upper energy threshold of 4 MeV, from which the proxy equilibrium factor method can apply

  17. Properties of polymer foils used as solid-state track detectors

    International Nuclear Information System (INIS)

    Spurny, F.

    1973-05-01

    Polymer foils were studied with a view to their application as solid-state alpha track detectors. The detection efficiency was determined as was its alpha energy dependence and the quality of the surface and the natural background of the foils were evaluated. The kinetics of etching was studied in three selected type of foils. Characteristic constants for the selected foils and methods of etching were calculated. The possible applications of the foils as track detectors are discussed and the effect is dealt with of the selected foil and of the method of chemical etching on the foil applicability in nuclear sciences, especially in fast neutron dosimetry and in alpha spectrometry. (author)

  18. Creation of nanoscale objects by swift heavy ion track manipulations

    International Nuclear Information System (INIS)

    Fink, D.; Petrov, A.; Stolterfoht, N.

    2003-01-01

    In this work we give an overview of the possibilities to create new objects with nanoscale dimensions with ion tracks, for future applications. This can be realized in two ways: by manipulation of latent swift heavy ion (SHI) tracks, or by embedding specific structures within etched SHI tracks. In the first case one can make use of irradiation effects such as phase transitions and chemical or structural changes along the tracks. In the latter case, one can fill etched SHI tracks with metals, semiconductors, insulating and conducting polymers, fullerite, or colloides. Wires and tubules with outer diameters, between about 50 nm and 5 μm and lengths of up to about 100 μm can be obtained. The most important production techniques are galvanic and chemical depositions. Ion Transmission Spectrometry has turned out to be an especially useful tool for the characterisation of the produced objects. Present studies aim at the construction of condensers, magnets, diodes, and sensors in etched tracks. An obstacle for the practical realization of smallest-size polymeric ion track devices is the statistical distribution of the ion tracks on the target areas, which yields some pixels without any track, and other pixels even with overlapping tracks on a given sample. In a first test experiment we demonstrate that one can, in principle, overcome that problem by taking self-ordered porous foils as masks for subsequent high-fluence SHI irradiation. (author)

  19. Introducing etch kernels for efficient pattern sampling and etch bias prediction

    Science.gov (United States)

    Weisbuch, François; Lutich, Andrey; Schatz, Jirka

    2018-01-01

    Successful patterning requires good control of the photolithography and etch processes. While compact litho models, mainly based on rigorous physics, can predict very well the contours printed in photoresist, pure empirical etch models are less accurate and more unstable. Compact etch models are based on geometrical kernels to compute the litho-etch biases that measure the distance between litho and etch contours. The definition of the kernels, as well as the choice of calibration patterns, is critical to get a robust etch model. This work proposes to define a set of independent and anisotropic etch kernels-"internal, external, curvature, Gaussian, z_profile"-designed to represent the finest details of the resist geometry to characterize precisely the etch bias at any point along a resist contour. By evaluating the etch kernels on various structures, it is possible to map their etch signatures in a multidimensional space and analyze them to find an optimal sampling of structures. The etch kernels evaluated on these structures were combined with experimental etch bias derived from scanning electron microscope contours to train artificial neural networks to predict etch bias. The method applied to contact and line/space layers shows an improvement in etch model prediction accuracy over standard etch model. This work emphasizes the importance of the etch kernel definition to characterize and predict complex etch effects.

  20. Comparison study of V-doped ZnO thin films on polycarbonate and quartz substrates deposited by RF magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Tomoya, E-mail: tomoya@ecei.tohoku.ac.jp; Chiba, Hiroshi; Kawashima, Tomoyuki; Washio, Katsuyoshi

    2016-04-30

    Vanadium (V) doped ZnO (VZO) thin films were deposited on flexible polymer and quartz substrates by RF magnetron sputtering, and influences of deposition parameters of V concentration, RF power and growth temperature on resistivity, transmittance and crystallinity were investigated. For the polymer substrates, both a high heat-resistant polycarbonate (PC) film and a functional-layer-coated PC film were adopted. The resistivity decreased gradually but the transmittance was worsened with increasing V concentration. Low RF power and high growth temperature improved both transparency and conductivity. By over-coating of the functional layers, c-axis orientation was deteriorated while low-resistivity and high-transmittance characteristics were achieved. Resistivity and average visible-transmittance (wavelength = 450–800 nm) of VZO films on untreated PC and over-coated PC substrates were 0.98 mΩ cm and 83.7%, and 1.2 mΩ cm and 80.3%, respectively, at V concentration of 2 at.%, RF power of 100 W and growth temperature of 175 °C. VZO films on the polymer substrates had slightly high resistivity but nearly the same optical transmittance, compared to those on quartz, under the identical deposition parameters. These results indicate that good electrical and optical properties can be achieved for the VZO films on PC substrate. - Highlights: • V-doped ZnO (VZO) was deposited on polymer substrate. • Effects of V concentration, RF power and growth temperature were investigated. • Resistivity decreased gradually with increasing V concentration. • Low RF power was suitable to obtain low resistivity and high transmittance. • High growth temperature improved both transparency and conductivity.

  1. Establishment and comparison of four constitutive relationships of PC/ABS from low to high uniaxial strain rates

    Science.gov (United States)

    Wang, Haitao; Zhang, Yun; Huang, Zhigao; Tang, Zhongbin; Wang, Yanpei; Zhou, Huamin

    2017-10-01

    The objective of this paper is to accurately predict the rate/temperature-dependent deformation of a polycarbonate (PC) and acrylonitrile-butadiene-styrene (ABS) blend at low, moderate, and high strain rates for various temperatures. Four constitutive models have been employed to predict stress-strain responses of PC/ABS under these conditions, including the DSGZ model, the original Mulliken-Boyce (M-B) model, the modified M-B model, and an adiabatic model named the Wang model. To more accurately capture the large deformation of PC/ABS under the high strain rate loading, the original M-B model is modified by allowing for the evolution of the internal shear strength. All of the four constitutive models above have been implemented in the finite element software ABAQUS/Explicit. A comparison of prediction accuracies of the four constitutive models over a wide range of strain rates and temperatures has been presented. The modified M-B model is observed to be more accurate in predicting the deformation of PC/ABS at high strain rates for various temperatures than the original M-B model, and the Wang model is demonstrated to be the most accurate in simulating the deformation of PC/ABS at low, moderate, and high strain rates for various temperatures.

  2. Mass spectrometry analysis of etch products from CR-39 plastic irradiated by heavy ions

    Science.gov (United States)

    Kodaira, S.; Nanjo, D.; Kawashima, H.; Yasuda, N.; Konishi, T.; Kurano, M.; Kitamura, H.; Uchihori, Y.; Naka, S.; Ota, S.; Ideguchi, Y.; Hasebe, N.; Mori, Y.; Yamauchi, T.

    2012-09-01

    As a feasibility study, gas chromatography-mass spectrometry (GC-MS) and matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) have been applied to analyze etch products of CR-39 plastic (one of the most frequently used solid states nuclear track detector) for the understanding of track formation and etching mechanisms by heavy ion irradiation. The etch products of irradiated CR-39 dissolved in sodium hydroxide solution (NaOH) contain radiation-induced fragments. For the GC-MS analysis, we found peaks of diethylene glycol (DEG) and a small but a definitive peak of ethylene glycol (EG) in the etch products from CR-39 irradiated by 60 MeV N ion beams. The etch products of unirradiated CR-39 showed a clear peak of DEG, but no other significant peaks were found. DEG is known to be released from the CR-39 molecule as a fragment by alkaline hydrolysis reaction of the polymer. We postulate that EG was formed as a result of the breaking of the ether bond (C-O-C) of the DEG part of the CR-39 polymer by the irradiation. The mass distribution of polyallylalcohol was obtained from the etch products from irradiated and unirradiated CR-39 samples by MALDI-MS analysis. Polyallylalcohol, with the repeating mass interval of m/z = 58 Da (dalton) between m/z = 800 and 3500, was expected to be produced from CR-39 by alkaline hydrolysis. We used IAA as a matrix to assist the ionization of organic analyte in MALDI-MS analysis and found that peaks from IAA covered mass spectrum in the lower m/z region making difficult to identify CR-39 fragment peaks which were also be seen in the same region. The mass spectrometry analysis using GC-MS and MALDI-MS will be powerful tools to investigate the radiation-induced polymeric fragments and helping to understand the track formation mechanism in CR-39 by heavy ions.

  3. Self-Propelled Soft Protein Microtubes with a Pt Nanoparticle Interior Surface.

    Science.gov (United States)

    Kobayakawa, Satoshi; Nakai, Yoko; Akiyama, Motofusa; Komatsu, Teruyuki

    2017-04-11

    Human serum albumin (HSA) microtubes with an interior surface composed of Pt nanoparticles (PtNPs) are self-propelled in aqueous H 2 O 2 medium. They can capture cyanine dye and Escherichia coli (E. coli) efficiently. Microtubes were prepared by wet templating synthesis by using a track-etched polycarbonate (PC) membrane with alternate filtrations of aqueous HSA, poly-l-arginine (PLA), and citrate-PtNPs. Subsequent dissolution of the PC template yielded uniform hollow cylinders made of (PLA/HSA) 8 PLA/PtNP stacking layers (1.16±0.02 μm outer diameter, ca. 23 μm length). In aqueous H 2 O 2 media, the soft protein microtubes are self-propelled by jetting O 2 bubbles from the open-end terminus. The effects of H 2 O 2 and surfactant concentrations on the velocity were investigated. The swimming microtube captured cyanine dye in the HSA component of the wall. Addition of an intermediate γ-Fe 3 O 4 layer allowed manipulation of the direction of movement of the tubule by using a magnetic field. Because the exterior surface is positively charged, the bubble-propelled microtubes adsorbed E. coli with high efficiency. The removal ratio of E. coli by a single treatment reached 99 %. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The relationship between fission track length and track density in apatite

    International Nuclear Information System (INIS)

    Laslett, G.M.; Gleadow, A.J.W.; Duddy, I.R.

    1984-01-01

    Fission track dating is based upon an age equation derived from a random line segment model for fission tracks. This equation contains the implicit assumption of a proportional relationship between the true mean length of fission tracks and their track density in an isotropic medium. Previous experimental investigation of this relationship for both spontaneous and induced tracks in apatite during progressive annealment model in an obvious fashion. Corrected equations relating track length and density for apatite, an anisotropic mineral, show that the proportionality in this case is between track density and a length factor which is a generalization of the mean track length combining the actual length and crystallographic orientation of the track. This relationship has been experimentally confirmed for induced tracks in Durango apatite, taking into account bias in sampling of the track lengths, and the effect of the bulk etching velocity. (author)

  5. Characterization of CR 39 nuclear track detector for use as a radon/thoron dosemeter

    International Nuclear Information System (INIS)

    Kandaiya, S.

    1988-02-01

    For the estimation of radon, thoron and their short-lived daughter products in air radon diffusion chambers with passive α-track etch detectors have been used. The report describes the properties of CR 39 track etch detectors in particular with respect to the spectrometric detection of α-particles in the energy range up to 8.77 MeV using chemical and a combination of chemical-electrochemical etching technique. In order to optimize the etching conditions for an α-energy discrimination in the energy range up to 8.77 MeV, the ECE track size diameter and the track density have been investigated as a function of the chemical pre-etching time using three electrical field strengths. In a mixed α-spectrum the contributions of various α-particles with energies between 4.6 to 8.77 MeV have been determined experimentally in CR 39 and compared with the spectral measurement using a surface barrier detector and the same irradiation geometry. Beside CR 39 detectors etched chemically and electrochemically, in addition surface barrier detectors and a Monte Carlo calculation have been used to evaluate the α-energy spectrum for thoron and its daughter products emitted by α-decays in the air volume and the plate-out of daughters at the inner surface on the diffusion chamber. (orig./HP) [de

  6. Migration of bisphenol A into water from polycarbonate baby bottles during microwave heating

    NARCIS (Netherlands)

    Ehlert, K.A.; Beumer, C.W.E.; Groot, M.C.E.

    2008-01-01

    A comprehensive migration database was established for bisphenol A from polycarbonate baby bottles into water during exposure to microwave heating. Eighteen different brands of polycarbonate baby bottles sold in Europe were collected. Initial residual content of bisphenol A and migration after

  7. Response of CR-39 to 0.9-2.5 MeV protons for KOH and NaOH etching solutions

    Science.gov (United States)

    Bahrami, F.; Mianji, F.; Faghihi, R.; Taheri, M.; Ansarinejad, A.

    2016-03-01

    In some circumstances passive detecting methods are the only or preferable measuring approaches. For instance, defining particles' energy profile inside the objects being irradiated with heavy ions and measuring fluence of neutrons or heavy particles in space missions are the cases covered by these methods. In this paper the ability of polyallyl diglycol carbonate (PADC) track detector (commercially known as CR-39) for passive spectrometry of proton particles is studied. Furthermore, the effect of KOH and NaOH as commonly used chemical etching solutions on the response of the detector is investigated. The experiments were carried out with protons in the energy range of 0.94-2.5 MeV generated by a Van de Graaff accelerator. Then, the exposed track dosimeters were etched in the two aforementioned etchants through similar procedure with the same normality of 6.25 N and the same temperature of 85 °C. Formation of the tracks was precisely investigated and the track diameters were recorded following every etching step for each solution using a multistage etching process. The results showed that the proposed method can be efficiently used for the spectrometry of protons over a wider dynamic range and with a reasonable accuracy. Moreover, NaOH and KOH outperformed each other over different regions of the proton energy range. The detection efficiency of both etchants was approximately 100%.

  8. Fast neutron personnel dosimetry by CR-39 plastics a new electrochemical etching procedure

    International Nuclear Information System (INIS)

    Djeffal, S.

    1984-07-01

    In the first part of this work a brief description of solid state nuclear track detectors, the principles of track registration and the different reading techniques are given. In the experimental part of the present work we systematically analysed different etching procedures and set a new electrochemical etching method, which enables us to develop a new fast neutron dosimeter. This fast neutron dosimeter makes possible the measurement of low neutron doses in the energy range from 10 Kev to 20 Mev with a reasonably flat energy response. These new developments are very attractive in personnel neutron dosimetry where nuclear emulsions are still used despite their insensitivity to neutron energies down to 500 Kev (i.e. the energy range one often encounters around nuclear facilities)

  9. Self-etch and etch-and-rinse adhesive systems in clinical dentistry.

    Science.gov (United States)

    Ozer, Fusun; Blatz, Markus B

    2013-01-01

    Current adhesive systems follow either an "etch-and-rinse" or "self-etch" approach, which differ in how they interact with natural tooth structures. Etch-and-rinse systems comprise phosphoric acid to pretreat the dental hard tissues before rinsing and subsequent application of an adhesive. Self-etch adhesives contain acidic monomers, which etch and prime the tooth simultaneously. Etch-and-rinse adhesives are offered as two- or three-step systems, depending on whether primer and bonding are separate or combined in a single bottle. Similarly, self-etch adhesives are available as one- or two-step systems. Both etch-and-rinse and self-etch systems form a hybrid layer as a result of resins impregnating the porous enamel or dentin. Despite current trends toward fewer and simpler clinical application steps, one-step dentin bonding systems exhibit bonding agent lower bond strengths and seem less predictable than multi-step etch-and-rinse and self-etch systems. The varying evidence available today suggests that the choice between etch-and-rinse and self-etch systems is often a matter of personal preference. In general, however, phosphoric acid creates a more pronounced and retentive etching pattern in enamel. Therefore, etch-and-rinse bonding systems are often preferred for indirect restorations and when large areas of enamel are still present. Conversely, self-etch adhesives provide superior and more predictable bond strength to dentin and are, consequently, recommended for direct composite resin restorations, especially when predominantly supported by dentin.

  10. Uranium in blood

    International Nuclear Information System (INIS)

    Koul, S.L.; Chadderton, L.T.

    1979-01-01

    When fission fragments pass through certain solids they leave trails of radiation damage which can be observed by transmission electron microscopy. If the solid can be chemically etched these tracks are 'developed' and brought within the resolving power of the light optical microscope. Since its introduction the etching technique has been used to reveal tracks formed due to the thermal neutron induced fission of U 235 atoms in many uranium bearing materials of both terrestrial and extraterrestrial origin. Successful experiments have been performed in determining the distribution of uranium in selected botanical species. On the basis of this most recent work it was decided to make a feasibility study of a determination of the concentration in human blood. This short report produces evidence not only that the fission track etching technique is useful for this purpose but that there are significant uranium concentration differences in blood taken from leukemia patients compared with samples taken from healthy norms. Whilst experiments of this kind generally employ direct registration of the fission fragments in the material itself, as with minerals, an alternative procedure is to employ some overlay, such as thin sheets of muscovite mica, or of a suitable plastic. In the present investigations the plastic Lexan polycarbonate (C 6 H 15 O 3 ) was selected as an overlay since it is easy to etch chemically. (author)

  11. Cytotoxic effects of polycarbonate-based orthodontic brackets by activation of mitochondrial apoptotic mechanisms

    NARCIS (Netherlands)

    Kloukos, D.; Taoufik, E.; Eliades, T.; Katsaros, C.; Eliades, G.

    2013-01-01

    OBJECTIVES: The aim of the study was to evaluate the biological effects of water eluents from polycarbonate based esthetic orthodontic brackets. METHODS: The composite polycarbonate brackets tested were Silkon Plus (SL, fiber-glass-reinforced), Elan ME (EL, ceramic particle-reinforced) and Elegance

  12. Application of solid state track detector to neutron dosimetry

    International Nuclear Information System (INIS)

    Tsuruta, Takao

    1979-01-01

    Though solid state track detectors (SSTD) are radiation measuring instrument for heavy charged particles by itself, it can be used as radiation measuring instrument for neutrons, if nuclear reactions such as (n, f) or (n, α) reaction are utilized. Since the means was found, which permits to observe the tracks of heavy charged particles in a solid with an optical microscope by chemically etching the tracks to enlarge them to etch pits, various types of detectors have been developed for the purpose of measuring neutron dose. The paper is described on the materials and construction of the SSTDs for neutron dosimetry, and the sensitivity is explained with mathematical equations. The features of neutron dosimetry with SSTDs are as follows: They are compact, and scarcely disturb neutron field, thus delicate dose distribution can be known; integration measurement is possible regardless of dose rate values because of integrating type detectors; it is not influenced by β-ray or γ-ray except the case when there is high energy radiation such as causing photonuclear reactions or high dose such as degrading solids, it has pretty high sensitivity; track fading is negligible during the normal measuring time around room temperature; and the etching images of tracks are relatively clear, and various automatic counting systems can be employed. (Wakatsuki, Y.)

  13. Application of solid state nuclear track detectors in radiation protection

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.; Mishra, U.C.

    1989-01-01

    This article reviews the current status of the application of nuclear track detectors with emphasis on recent developments in the field of radiation protection. Track etch detectors have been used for the measurements of low level radiation in the environment, fast neutron and radon daughter inhalation dose. Recent developments in the field of dosimetry seem to be promising. In fast neutron dosimetry, track etch detectors can be used without inclusion of fissile materials by using the electrochemical etching technique. These detectors can provide important information in the energy range upto 250 keV. Survey of this range of energy with TLD is difficult because they are extremely energy dependent and over-respond to low energy neutrons. Measurement of radon using track detectors can help to lower the cost of the radon dosimeters. Certain detectors are sensitive to alpha particles from radon and their progeny. Higher sensitivity permits their use in a passive type of personnel dosimeter, which does not require the troublesome aspects of air sampling for the collection of radon daughter samples. (author), 38 refs., 8 tabs., 12 figs

  14. Polycarbonate-based ordered arrays of electrochemical nanoelectrodes obtained by e-beam lithography

    Energy Technology Data Exchange (ETDEWEB)

    Moretto, L M; De Leo, M; Ugo, P [Department of Molecular Sciences and Nanosystems, University Ca' Foscari of Venice, Santa Marta 2137, 30123 Venice (Italy); Tormen, M; Carpentiero, A, E-mail: ugo@unive.it [CNR-IOM, TASC Laboratory, Basovizza S S 14 km 163.5, 34149 Trieste (Italy)

    2011-05-06

    Ordered arrays of nanoelectrodes for electrochemical use are prepared by electron beam lithography (EBL) using polycarbonate as a novel e-beam resist. The nanoelectrodes are fabricated by patterning arrays of holes in a thin film of polycarbonate spin-coated on a gold layer on Si/Si{sub 3}N{sub 4} substrate. Experimental parameters for the successful use of polycarbonate as high resolution EBL resist are optimized. The holes can be filled partially or completely by electrochemical deposition of gold. This enables the preparation of arrays of nanoelectrodes with different recession degree and geometrical characteristics. The polycarbonate is kept on-site and used as the insulator that separates the nanoelectrodes. The obtained nanoelectrode arrays (NEAs) exhibit steady state current controlled by pure radial diffusion in cyclic voltammetry for scan rates up to approximately 50 mV s{sup -1}. Electrochemical results showed satisfactory agreement between experimental voltammograms and suitable theoretical models. Finally, the peculiarities of NEAs versus ensembles of nanoelectrodes, obtained by membrane template synthesis, are critically evaluated.

  15. Polypropylene and polycarbonate radiosterilization: effects on the stress resistance

    International Nuclear Information System (INIS)

    Musico Filho, W.; Terence, M.C.; Guedes, S.M.L.; Araujo, E.S. de

    1994-01-01

    The gamma radiation effect on polymer sterilization used in the fabrication of medical supplies, national polycarbonate and polypropylene, was studied in function of the tensile strength. During the polycarbonate irradiation occur the scission of polymer chain and the crosslinking/scission of the polypropylene, but in the sterilization dose, 25 kGy, does not occur expressive changes in the tensile strength. After the polypropylene sterilization the tensile strength continues increasing as consequence of the crosslinking. Since the sixth day the oxidation reaction predominates as consequence of the radical migration to the amorphous region. (author). 7 refs, 6 figs

  16. Measurement of track opening contours of oblique incident 4He and 7Li-ions in CR-39: Relevance for calculation of track formation parameters

    International Nuclear Information System (INIS)

    Hermsdorf, D.; Reichelt, U.

    2010-01-01

    Solid State Nuclear Track Detectors (SSNTD) irradiated in realistic radiation fields exhibits after chemical etching very complex track images resulting from different species of particles and their energy spectra and randomly distributed angles of incidence or emission. Reading out such an etched detector surface with a light microscope, quite different track opening contours are observed. Beside the number of tracks, typically their major and minor axes are measured. In this work following problems arising from such experimental situations will be investigated: ·the measurement of track contour parameters for oblique incident 4 He and 7 Li-ions of different energies and angles in CR-39 detectors ·the theoretical description of the angular variation of both axes. ·the possibility to extract physical and spectroscopic information from major and minor track axes. This analysis is based on an intensive experimental program and the comprehensive study of theoretical models available for description of track revealing processes in CR-39.

  17. Automatic counting of fission fragments tracks using the gas permeation technique

    CERN Document Server

    Yamazaki, I M

    1999-01-01

    An automatic counting system for fission tracks induced in a polycarbonate plastic Makrofol KG (10 mu m thickness) is described. The method is based on the gas transport mechanism proposed by Knudsen, where the gas permeability for a porous membrane is expected to be directly related to its track density. In this work, nitrogen permeabilities for several Makrofol films, with different fission track densities, have been measured using an adequate gas permeation system. The fission tracks were produced by irradiating Makrofol foils with a 252Cf calibrated source in a 2 pi geometry. A calibration curve fission track number versus nitrogen permeability has been obtained, for track densities higher than 1000/cm sup 2 , where the spark gap technique and the visual methods employing a microscope, are not appropriate for track counting.

  18. Employment of the polycarbonates Makrofol-DE and CR-39 for neutron radiography

    International Nuclear Information System (INIS)

    Pereira, Marco Antonio Stanojev

    2000-01-01

    The track-etch method was employed for Neutron Radiography purposes. The solid state nuclear track detectors Makrofol-DE and CR-39 together with a natural boron converter screen have been used as imaging systems. In order to determine their radiographic characteristics, the imaging systems were irradiated up to neutron exposures around 6x10 10 /cm 2 in a radiography facility installed at the IEA-R1 Nuclear Research Reactor and the detectors developed between 2 and 65 minutes. The main goal of this work was determine the radiography conditions for which the best contrast and resolution are obtained at the image. These conditions are: - Makrofol-DE: neutron exposure between 2x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 6 minutes; CR-39: neutron exposure between 3x10 9 n/cm 2 and 2x10 10 n/cm 2 and developing time 25 minutes. The present results were compared with those ones determined to other track detectors, and discussed according to the theory of the image formation in solid state nuclear track detectors based on the optical properties of a single track. (author)

  19. Twin-screw extrusion of multi walled carbon nanotubes reinforced polycarbonate composites: Investigation of electrical and mechanical properties

    International Nuclear Information System (INIS)

    Mack, C; Sathyanarayana, S; Weiss, P; Mikonsaari, I; Hübner, C; Henning, F; Elsner, P

    2012-01-01

    1, 3 and 5 wt.% multi walled carbon nanotubes (MWCNT) reinforced polycarbonate (PC) composites were processed in a twin-screw extruder (L/D=52) with two different screw speeds, throughputs and screw configurations. Extruded strands were characterized for dispersion and measurement of electrical resistivities while the pelletized extrudates were injection molded to produce samples for mechanical and further electrical property measurements. The absolute resistance of the melt was recorded with an online melt resistance setup developed by our group. The volume resistivity of pure PC (10 17 Ω.m) was lowered to 10 4 − 10 5 Ω.m on an injection molded PC-1 wt. % MWCNT composite. 3 wt.% MWCNT incorporated composites showed volume resistivity less than 1 Ω.m independent of process conditions. At lower filler contents the volume resistivity of injection molded samples were higher than those observed on the extruded strands and this effect diminished with increasing MWCNT loadings; owing to the loss of CNT network contacts due to shear induced filler orientation and core-skin effects. The quality of dispersion was exceptional for all filler concentrations at any process condition owing to the affinity of MWCNT towards PC due to the lower interfacial energy difference between the reactants and high polarity of PC. The modulus and strength of the composites increased with filler addition, however at 5 wt.% filler loading the strength of the composites processed with lower SMEs was less than that observed on the 1 wt.% MWCNT reinforced PC composite. The elongation of the composites at maximum tensile strength were comparable to that of neat PC except for composites with 5 wt.% MWCNT loading processed with lower SMEs. Composites with identical filler loadings which were processed with higher SMEs showed higher notched impact strength values principally because of the ability of very well dispersed filler fractions to inhibit crack propagation. The significance of the

  20. Uranium fission track length distribution modelling for retracing chronothermometrical history of minerals

    International Nuclear Information System (INIS)

    Rebetez, M.

    1987-01-01

    Spontaneous fission of uranium 238 isotope contained in certain minerals creates damage zones called latent tracks, that can be etched chemically. The observation of these etched tracks and the measurement of their characteristics using an optical microscope are the basis of several applications in the domain of the earth sciences. First, the determination of their densities permits dating a mineral and establishing uranium mapping of rocks. Second, the measurement of their lengths can be a good source of information for retracing the thermal and tectonic history of the sample. The study of the partial annealing of tracks in apatite appears to be the ideal indicator for the evaluation of petroleum potential of a sedimentary basin. To allow the development of this application, it is necessary to devise a theoretical model of track length distributions. The model which is proposed takes into account the most realistic hypotheses concerning registration, etching and observation of tracks. The characteristics of surface tracks (projected lengths, depths, inclination angles, real lengths) and confined tracks (Track IN Track and Track IN Cleavage) are calculated. Surface tracks and confined tracks are perfectly complementary for chrono-thermometric interpretation of complex geological histories. The method is applied to the case of two samples with different tectonic history, issued from the cretaceous alcalin magmatism from the Pyrenees (Bilbao, Spain). A graphic method of distribution deconvolution is proposed. Finally, the uranium migration, depending on the hydrothermal alteration, is studied on the granite from Auriat (France) [fr

  1. UV-induced graft polymerization of acrylic acid in the sub-micronchannels of oxidized PET track-etched membrane

    Science.gov (United States)

    Korolkov, Ilya V.; Mashentseva, Anastassiya A.; Güven, Olgun; Taltenov, Abzal A.

    2015-12-01

    In this article, we report on functionalization of track-etched membrane based on poly(ethylene terephthalate) (PET TeMs) oxidized by advanced oxidation systems and by grafting of acrylic acid using photochemical initiation technique for the purpose of increasing functionality thus expanding its practical application. Among advanced oxidation processes (H2O2/UV) system had been chosen to introduce maximum concentration of carboxylic acid groups. Benzophenone (BP) photo-initiator was first immobilized on the surfaces of cylindrical pores which were later filled with aq. acrylic acid solution. UV-irradiation from both sides of PET TeMs has led to the formation of grafted poly(acrylic acid) (PAA) chains inside the membrane sub-micronchannels. Effect of oxygen-rich surface of PET TeMs on BP adsorption and subsequent process of photo-induced graft polymerization of acrylic acid (AA) were studied by ESR. The surface of oxidized and AA grafted PET TeMs was characterized by UV-vis, ATR-FTIR, XPS spectroscopies and by SEM.

  2. On the application of solid state nuclear track detectors (SSNTD)

    International Nuclear Information System (INIS)

    Almasi, G.

    1983-01-01

    The thesis presented deals with theoretical and technical aspects of the use of SSNTDs for the registration of charged particles. For thin SSNTD relations between the geometrical parameters of the etch tracks, the etch rate ratio and the etched-off thickness are given which together with calculations on the particle range versus energy make an identification of the particles with respect to their energy as well as their nature possible. For the purpose of the measurement of Radon and α-emitting Radon daughters in living rooms the geometry of the cups has been optimized. The calibration factors have been calculated and verified experimentally. For the evaluation of the track density of thin SSNTD a conductance cell has been set up. Radon concentrations and equilibrium factors were measured over a period of half a year in rooms made of concrete, wood and bricks having identical geometrical dimensions and ventilation rates. The results obtained are discussed briefly. In a long series of experiments which showed the important role of the electroforetic forces involved the 'sequential electrical and chemical etching' technique proposed first by Tommasino and coworkers in 1979 was modified. By means of an optimized choice of the electrolytic solutions the development time could be reduced from about two weeks to two to three hours. Therefore this technique seems to be a useful method to obtain enlarged etch tracks without background interference. (Author)

  3. Response of CR-39 to 0.9–2.5 MeV protons for KOH and NaOH etching solutions

    Energy Technology Data Exchange (ETDEWEB)

    Bahrami, F. [Department of Medical Radiation Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Mianji, F., E-mail: fmianji@aeoi.org.ir [Nuclear Science & Technology Research Institute, Tehran (Iran, Islamic Republic of); Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Faghihi, R. [Department of Medical Radiation Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Taheri, M. [Iran Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of); Ansarinejad, A. [Nuclear Science & Technology Research Institute, Tehran (Iran, Islamic Republic of)

    2016-03-21

    In some circumstances passive detecting methods are the only or preferable measuring approaches. For instance, defining particles' energy profile inside the objects being irradiated with heavy ions and measuring fluence of neutrons or heavy particles in space missions are the cases covered by these methods. In this paper the ability of polyallyl diglycol carbonate (PADC) track detector (commercially known as CR-39) for passive spectrometry of proton particles is studied. Furthermore, the effect of KOH and NaOH as commonly used chemical etching solutions on the response of the detector is investigated. The experiments were carried out with protons in the energy range of 0.94–2.5 MeV generated by a Van de Graaff accelerator. Then, the exposed track dosimeters were etched in the two aforementioned etchants through similar procedure with the same normality of 6.25 N and the same temperature of 85 °C. Formation of the tracks was precisely investigated and the track diameters were recorded following every etching step for each solution using a multistage etching process. The results showed that the proposed method can be efficiently used for the spectrometry of protons over a wider dynamic range and with a reasonable accuracy. Moreover, NaOH and KOH outperformed each other over different regions of the proton energy range. The detection efficiency of both etchants was approximately 100%.

  4. Applying graphene oxide nano-film over a polycarbonate nanoporous membrane to monitor E. coli by infrared spectroscopy.

    Science.gov (United States)

    Singh, Krishna Pal; Dhek, Neeraj Singh; Nehra, Anuj; Ahlawat, Sweeti; Puri, Anu

    2017-01-05

    Nano-biosensors are excellent monitoring tools for rapid, specific, sensitive, inexpensive, in-field, on-line, and/or real-time detection of pathogens in foods, soil, air, and water samples. A variety of nano-materials (metallic, polymeric, and/or carbon-based) were employed to enhance the efficacy, efficiency, and sensitivity of these nano-biosensors, including graphene-based materials, especially graphene oxide (GO)-based materials. GO bears many oxygen-bearing groups, enabling ligand conjugation at the high density critical for sensitive detection. We have fabricated GO-modified nano-porous polycarbonate track-etched (PCTE) membranes that were conjugated to an Escherichia coli-specific antibody (Ab) and used to detect E. coli. The random distribution of nanopores on the PCTE membrane surface and the bright coating of the GO onto the membrane were confirmed by scanning electron microscope. Anti-E. coli β-gal Abs were conjugated to the GO surface via 1-ethyl-3,3-dimethylaminopropyl carbodiimide hydrochloride-N-hydroxysuccinimide chemistry; antibody coating was confirmed by the presence of a characteristic IR peak near 1600cm(-1). A non-corresponding Ab (anti-Pseudomonas) was used as a negative control under identical conditions. When E. coli interacted anti-E.coli β-gal with Ab-coated GO-nano-biosensor units, we observed a clear shift in the IR peak from 3373.14 to 3315cm(-1); in contrast, we did not observe any shift in IR peaks when the GO unit was coated with the non-corresponding Ab (anti-Pseudomonas). Therefore, the detection of E. coli using the described GO-nano-sensor unit is highly specific, is highly selective and can be applied for real-time monitoring of E. coli with a detection limit between 100μg/mL and 10μg/mL, similar to existing detection systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Further development of a track detector as the spectrometer of linear energy transfer

    International Nuclear Information System (INIS)

    Spurny, F.; Bednar, J.; Vlcek, B.; Botollier-Depois, J.F.

    1998-01-01

    Track revealing in a track etch detector is a phenomenon related to the linear energy transfer (LET) of the particle registered. The measurements of track parameters permit to determine the LET corresponding to each revealed track, i.e. LET spectrum. We have recently developed a spectrometer of LET based on the chemically etched polyallyldiglycolcarbonate (PADC). In this contribution the results obtained with such spectrometer in some neutron fields are presented, analyzed and discussed. Several radionuclide neutron sources have been used, LET spectrometer has been also exposed in high energy neutron reference fields at CERN and JINR Dubna, and on board aircraft. (author)

  6. Etch bias inversion during EUV mask ARC etch

    Science.gov (United States)

    Lajn, Alexander; Rolff, Haiko; Wistrom, Richard

    2017-07-01

    The introduction of EUV lithography to high volume manufacturing is now within reach for 7nm technology node and beyond (1), at least for some steps. The scheduling is in transition from long to mid-term. Thus, all contributors need to focus their efforts on the production requirements. For the photo mask industry, these requirements include the control of defectivity, CD performance and lifetime of their masks. The mask CD performance including CD uniformity, CD targeting, and CD linearity/ resolution, is predominantly determined by the photo resist performance and by the litho and etch processes. State-of-the-art chemically amplified resists exhibit an asymmetric resolution for directly and indirectly written features, which usually results in a similarly asymmetric resolution performance on the mask. This resolution gap may reach as high as multiple tens of nanometers on the mask level in dependence of the chosen processes. Depending on the printing requirements of the wafer process, a reduction or even an increase of this gap may be required. A potential way of tuning via the etch process, is to control the lateral CD contribution during etch. Aside from process tuning knobs like pressure, RF powers and gases, which usually also affect CD linearity and CD uniformity, the simplest knob is the etch time itself. An increased over etch time results in an increased CD contribution in the normal case. , We found that the etch CD contribution of ARC layer etch on EUV photo masks is reduced by longer over etch times. Moreover, this effect can be demonstrated to be present for different etch chambers and photo resists.

  7. Development and application of the electrochemical etching technique. Annual progress report

    Energy Technology Data Exchange (ETDEWEB)

    1980-08-01

    This annual progress report documents further advances in the development and application of electrochemical etching of polycarbonate foils (ECEPF) for fast, intermediate, and thermal neutron dosimetry as well as alpha particle dosimetry. The fast (> 1.1 MeV) and thermal neutron dosimetry techniques were applied to a thorough investigation of the neutron contamination inherent in and about the primary x-ray beam of several medical therapy electron accelerators. Because of the small size of ECEPF dosimeters in comparison to other neutron meters, they have an unusually low perturbation of the radiation field under measurement. Due to this small size and the increased sensitivity of the ECEPF dosimeter over current techniques of measuring neutrons in a high photon field, the fast neutron contamination in the primary x-ray beam of all the investigated accelerators was measured with precision and found to be greater than that suggested by the other, more common, neutron dosimetry methods.

  8. Development and application of the electrochemical etching technique. Annual progress report

    International Nuclear Information System (INIS)

    1980-08-01

    This annual progress report documents further advances in the development and application of electrochemical etching of polycarbonate foils (ECEPF) for fast, intermediate, and thermal neutron dosimetry as well as alpha particle dosimetry. The fast (> 1.1 MeV) and thermal neutron dosimetry techniques were applied to a thorough investigation of the neutron contamination inherent in and about the primary x-ray beam of several medical therapy electron accelerators. Because of the small size of ECEPF dosimeters in comparison to other neutron meters, they have an unusually low perturbation of the radiation field under measurement. Due to this small size and the increased sensitivity of the ECEPF dosimeter over current techniques of measuring neutrons in a high photon field, the fast neutron contamination in the primary x-ray beam of all the investigated accelerators was measured with precision and found to be greater than that suggested by the other, more common, neutron dosimetry methods

  9. Studies on the effect of compatibilizers on mechanical, thermal and flow properties of polycarbonate/poly (butylene terephthalate) blends

    Science.gov (United States)

    Kumar, Ravindra; Kar, Kamal K.; Kumar, Vijai

    2018-01-01

    Bisphenol-A polycarbonate (PC) and poly(butylene terephthalate) (PBT) were melt blended with ethylene-n-butylacrylate-glycidylmethacrylate terpolymer (E-BA-GMA) at various proportions in order to study the effects of compatibilizers on mechanical, thermal and flow properties of blends. Furthermore, on the basis of this study, PC and PBT were melt-blended at 60/40 proportion with three different compatibilizers viz., ethylene-n-butylacrylate copolymer (E-BA), E-BA-GMA and random copolymer of ethylene and glycidylmethacrylate (E-GMA) at 3 phr loading in a co-rotating twin screw extruder. Tensile, flexural and impact tests were carried out on injection molded samples of PC/PBT blends. The notched izod impact strength increases enormously (˜2-3 times) on addition of any one of the three compatibilizers, and elongation at break (%) also improves tremendously (3, 5 and 4 times) on incorporation of E-BA, E-BA-GMA and E-GMA copolymer, respectively while other mechanical properties decreases slightly (3%-8%) on addition of any one of these compatibilizers. The heat deflection temperature (HDT) raises ˜8 °C-9 °C on addition of either E-BA-GMA or E-GMA, while E-BA shows a negative effect on HDT. The melt flow index diminishes significantly (˜5%-20%) on incorporation of these compatibilizers. The morphology studies via scanning electron microscopy of these four blends were carried out to confirm the mechanical results.

  10. Triton, deuteron and proton responses of the CR-39 track detector

    Energy Technology Data Exchange (ETDEWEB)

    Yamauchi, Tomoya; Matsumoto, Hiroyoshi; Oda, Keiji [Kobe Univ. of Mercantile Marine (Japan)

    1996-07-01

    In the present study, we assessed the response of the CR-39 detector to proton, deuteron and triton from their etch-pit growth curves obtained by multi-step etching technique and the difference among their track registration properties was discussed. In order to avoid incorrect evaluation due to the missing track effect, particle irradiation was performed at various incident energies. The response function, S(R), etch rate ratio, S, as a function of the residual range, R, was experimentally evaluated for all hydrogen isotopes by this method. In the next, we obtained another form of response functions of S(E), S({beta}) and S(LET{sub 200}), which were presented as functions of the particle energy, E, the particle velocity, {beta}(=v/c), and the linear energy transfer in the case where the cut-off energy is 200 eV, LET{sub 200}, respectively. These information will be useful also in understanding the fundamentals of the latent track formation mechanism in the plastic track detectors. (J.P.N.)

  11. Constitutive modeling of polycarbonate over a wide range of strain rates and temperatures

    Science.gov (United States)

    Wang, Haitao; Zhou, Huamin; Huang, Zhigao; Zhang, Yun; Zhao, Xiaoxuan

    2017-02-01

    The mechanical behavior of polycarbonate was experimentally investigated over a wide range of strain rates (10^{-4} to 5× 103 s^{-1}) and temperatures (293 to 353 K). Compression tests under these conditions were performed using a SHIMADZU universal testing machine and a split Hopkinson pressure bar. Falling weight impact testing was carried out on an Instron Dynatup 9200 drop tower system. The rate- and temperature-dependent deformation behavior of polycarbonate was discussed in detail. Dynamic mechanical analysis (DMA) tests were utilized to observe the glass (α ) transition and the secondary (β ) transition of polycarbonate. The DMA results indicate that the α and β transitions have a dramatic influence on the mechanical behavior of polycarbonate. The decompose/shift/reconstruct (DSR) method was utilized to decompose the storage modulus into the α and β components and extrapolate the entire modulus, the α-component modulus and the β-component modulus. Based on three previous models, namely, Mulliken-Boyce, G'Sell-Jonas and DSGZ, an adiabatic model is proposed to predict the mechanical behavior of polycarbonate. The model considers the contributions of both the α and β transitions to the mechanical behavior, and it has been implemented in ABAQUS/Explicit through a user material subroutine VUMAT. The model predictions are proven to essentially coincide with the experimental results during compression testing and falling weight impact testing.

  12. Uranium trace and alpha activity characterization of coal and fly ash using particle track etch technique

    International Nuclear Information System (INIS)

    Chakravarti, S.K.

    1991-01-01

    Uranium is extensively found in carbonaceous components of sedimentary rocks and is considered to be accumulated in coals during the coalification process through the geological times. Burning of coal is mainly responsible for a manifold increase in the concentration of radioactive nuclides in atmosphere precipitates. Fly ash being an incombustible residue and formed from 90% of the inorganic material in coal, escapes into the atmosphere and constitutes a potential hazard. Also its use as one of the pozzolanic materials in the products of concrete, bricks etc and filling of ground cavities is even more hazardous because of the wall radioactivity, besides emission and diffusion of radon. This paper reports a simple method called Particle Track Etch (PTE) technique, for trace determination of uranium content in coal and fly ash samples by making use of low cost and versatile plastic detectors known as Solid State Nuclear Track Detectors (SSNTDs). Total alpha activity has also been estimated using these SSNTDs. The values of uranium concentration in coal samples are found to range from 1.1 to 3.6 ppm (uniform component) and 33 to 46 ppm (non-uniform part) whereas in fly ash, it varies from 8 to 11 ppm (uniform) and 55 to 71 ppm in non-uniform range. It is also observed that the alpha activity is a function of uranium concentration for most of the natural samples of coal studied except for mixtures of fly ash samples where relationship is found to be on higher side. (author). 13 refs., 2 tabs., 1 fig

  13. Polycarbonate-silsesquioxane and polycarbonate-siloxane nanocomposites: Synthesis, characterization, and application in the fabrication of porous inorganic films

    Science.gov (United States)

    Abdallah, Jassem

    Three types of poly(bicycle[2.2.1]heptane carbonate) or poly(norbornane carbonate) or PNC oligomers were synthesized and characterized via spectroscopic methods and elemental analyses to validate their chemical structures. End-group analyses were used to estimate the degree of polymerization of the oligomers via the use of proton nuclear magnetic resonance (1H NMR) results. Random-coil and rigid-rod models were used to estimate the sizes of individual PNC chains based on the degrees of polymerization calculated from NMR data. Due to the small sizes of the PNC chains, dynamic light scattering (DLS) was incapable of measuring the hydrodynamic radii, RH, of individual chains. Attempts at using gel permeation chromatography (GPC) data to estimate the hydrodynamic radii of individual chains consistently provided values that were an order of magnitude smaller than the estimated sizes of individual chains based on random-coil calculations. The thermal properties of PNCs were determined via differential scanning calorimetry (DSC) and thermogravimetric analyses (TGAs). All three types of PNC structures were both thermally-labile and acidolytically-labile, allowing them to be used as sacrificial materials in both direct-write and thermally-processed template systems. TGA data was used to determine the kinetic parameters for the thermolytic decomposition reactions and evolved-gas analysis via mass spectrometry (TGA-MS) was used to validate the mechanisms for polycarbonate thermolysis reactions that have been previously proposed in literature. PNC oligomers were freely-mixed with hydrogen silsesquioxane (HSQ) to form solutions that were spin-coated to form templated films. Ellipsometry and dielectric measurements were used to track the changes in the optical and dielectric properties of templated films and effective medium approximations were used to estimate the level of porosity incorporated within each porous film. Transmission electron microscopy (TEM) showed that the free

  14. Thermal analysis of used and radiation treated polycarbonate (L-MW) biomaterial

    International Nuclear Information System (INIS)

    Jayabalan, M.; Sreenivasan, K.; Nair, P.D.; Jalajamani, K.V.

    1988-01-01

    γ-radiation treatment of radiation sterilized polycarbonate biomaterials has been carried out to ensure efficient disposal by incineration. Low molecular weight polycarbonate sterilized with 2.5 Mrad dose of γ-radiation was further treated with different doses of γ-radiation. The radiation-treated samples were subjected to thermogravimetry. The sterilized sample and the 7.5 Mrad-treated sample showed similar properties. These samples do not leave any residue during thermal decomposition. (author). 5 refs., 3 tables

  15. Influence of tracks densities in solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Guedes O, S.; Hadler N.; Lunes, P.; Saenz T, C.

    1996-01-01

    When Solid State Nuclear Track Detectors (SSNTD) is employed to measure nuclear tracks produced mainly by fission fragments and alpha particles, it is considered that the tracks observation work is performed under an efficiency, ε 0 , which is independent of the track density (number of tracks/area unit). There are not published results or experimental data supporting such an assumption. In this work the dependence of ε 0 with track density is studied basing on experimental data. To perform this, pieces of CR-39 cut from a sole 'mother sheet' were coupled to thin uranium films for different exposition times and the resulting ratios between track density and exposition time were compared. Our results indicate that ε 0 is constant for track densities between 10 3 and 10 5 cm -2 . At our etching conditions track overlapping makes impossible the counting for densities around 1.7 x 10 5 cm -2 . For track densities less than 10 3 cm -2 , ε 0 , was not observed to be constant. (authors). 4 refs., 2 figs

  16. Progress in the application of solid-state track recorders to reactor physics experiments

    International Nuclear Information System (INIS)

    Besant, C.B.; Ipson, S.S.

    1969-03-01

    Heavily ionising particles passing through insulating materials cause tracks due to damage. These strain energy fields may be observed directly with an electron microscope or, after etching, the tracks may be seen with an optical microscope. The etching solution penetrates the damaged portion of the material and enlarges the hole if the etching is continued. This technique has been applied to detecting fission fragments from fissions taking place in a thin source of fissile material. The source, together with the insulating material is called a Solid-State Track Recorder and has been applied to the measurement of fission ratios in the fast critical assembly ZEBRA at Winfrith. The main disadvantage of the technique has been in counting tracks by eye which is laborious and subject to the human element. This has been overcome by counting tracks with a 'Quantimet' Computer Image Analyser. Absolute fission rate measurements are also discussed and it has been shown that measurements to an accuracy of better than ± 1% should be possible with this technique. (author)

  17. UV-irradiation effects on polyester nuclear track detector

    International Nuclear Information System (INIS)

    Agarwal, Chhavi; Kalsi, P.C.

    2010-01-01

    The effects of UV irradiation (λ=254 nm) on polyester nuclear track detector have been investigated employing bulk-etch technique, UV-visible spectrophotometry and infra-red spectrometry (FTIR). The activation energy values for bulk-etching were found to decrease with the UV-irradiation time indicating the scission of the polymer. Not much shift in the absorption edge due to UV irradiation was seen in the UV-visible spectra. FTIR studies also indicate the scission of the chemical bonds, thereby further validating the bulk-etch rate results.

  18. Application of the chemical vapor-etching in polycrystalline silicon solar cells

    International Nuclear Information System (INIS)

    Ben Rabha, M.; Saadoun, M.; Boujmil, M.F.; Bessais, B.; Ezzaouia, H.; Bennaceur, R.

    2005-01-01

    This paper reports a study of the application of chemical vapor-etching (CVE) for the rear surface and in the emitter of polycrystalline silicon (pc-Si) solar cells. The CVE technique consists of exposing pc-Si wafers to a mixture of HF/HNO 3 . This technique is used to groove the rear surface of the pc-Si wafers for acid vapors rich in HNO 3 (HNO 3 /HF > 1/4), in order to realize rear-buried metallic contacts (RBMC) and the formation of a porous silicon (PS) layer on the frontal surface of the cell for volume ratio of HNO 3 /HF = 1/7. A significant increase of the spectral response in the long wavelength range was observed when a RBMC is formed. This increase was attributed to the reduction of the effective thickness of the base of the cells and grain boundary Al gettering. The achievement of a PS layer on the emitter of the pc-Si cells passivates the surface and reduces the reflectivity. The dark I-V characteristics of pc-Si cells with emitter-based PS show an important reduction of the reverse current together with an improvement of the rectifying behaviour. The I-V characteristic under AM1.5 illumination shows an enhancement of both short circuit current density and fill factor. The internal quantum efficiency is improved, particularly in the short wavelengths region

  19. Influence of high frequency ex-electric field on etching process and shape of pores for nuclear track film

    International Nuclear Information System (INIS)

    Chen Hui; Wang Yulan; Xu Shiping; Wang Jianchen

    2011-01-01

    To assess the details of the chemical etching process of polyethylene terephthalate (PET), the current signals during the whole etching process were recorded with the etching apparatus. The background-current was studied, which illustrated that it was mainly determined by the electric capacity of the etching system and was influenced by the thickness of the membrane but not by the temperature. According to the record of the current change during the etching process, it was found that the process can be divided into three phases. The influences of the existence and intensity of the ex-electric field on the breakthrough time and shape of pores were also studied. The existence of ex-electric field could shorten the breakthrough time and shape the pores more close to column. And these two phenomenons could be strengthened as the intensity of the electric field rose, and yet would reach a plateau when the intensity gets near 10 V/cm. (authors)

  20. Alpha particle track coloration in CR-39: Improved observability

    CERN Document Server

    Oezguemues, A

    1999-01-01

    A comparative study of the observability of alpha particle tracks in CR-39 was performed with an optical microscope before and after coloration. The implantation of ink helped in observing the damage zones. At first glance through the microscope, the coloration makes the tracks stand out right away. This coloration is helpful, from the start, in the morphological study of the tracks (size, area, orientation, shape, perimeter). This operation is advantageous in distinguishing the alpha particle tracks from stains or scratches. Thus, the routine counting of the tracks is more easily performed. Consequently, this procedure allowed us: to decrease significantly the standard deviation of the approximate total of the parameters given from the image analysis system (Olympus CUE2); to envision the possibility of reasonably decreasing the etching time in order to limit the loss of information caused by the destruction of the CR-39 during chemical etching and to use a weaker enlarging lens in order to cover a larger fi...

  1. Effects of closed immersion filtered water flow velocity on the ablation threshold of bisphenol A polycarbonate during excimer laser machining

    International Nuclear Information System (INIS)

    Dowding, Colin; Lawrence, Jonathan

    2010-01-01

    A closed flowing thick film filtered water immersion technique ensures a controlled geometry for both the optical interfaces of the flowing liquid film and allows repeatable control of flow-rate during machining. This has the action of preventing splashing, ensures repeatable machining conditions and allows control of liquid flow velocity. To investigate the impact of this technique on ablation threshold, bisphenol A polycarbonate samples have been machined using KrF excimer laser radiation passing through a medium of filtered water flowing at a number of flow velocities, that are controllable by modifying the liquid flow-rates. An average decrease in ablation threshold of 7.5% when using turbulent flow velocity regime closed thick film filtered water immersed ablation, compared to ablation using a similar beam in ambient air; however, the use of laminar flow velocities resulted in negligible differences between closed flowing thick film filtered water immersion and ambient air. Plotting the recorded threshold fluence achieved with varying flow velocity showed that an optimum flow velocity of 3.00 m/s existed which yielded a minimum ablation threshold of 112 mJ/cm 2 . This is attributed to the distortion of the ablation plume effected by the flowing immersion fluid changing the ablation mechanism: at laminar flow velocities Bremsstrahlung attenuation decreases etch rate, at excessive flow velocities the plume is completely destroyed, removing the effect of plume etching. Laminar flow velocity regime ablation is limited by slow removal of debris causing a non-linear etch rate over 'n' pulses which is a result of debris produced by one pulse remaining suspended over the feature for the next pulse. The impact of closed thick film filtered water immersed ablation is dependant upon beam fluence: high fluence beams achieved greater etch efficiency at high flow velocities as the effect of Bremsstrahlung attenuation is removed by the action of the fluid on the plume; low

  2. Continuous wave ultraviolet radiation induced frustration of etching in lithium niobate single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Mailis, S.; Riziotis, C.; Smith, P.G.R.; Scott, J.G.; Eason, R.W

    2003-02-15

    Illumination of the -z face of congruent lithium niobate single crystals with continuous wave (c.w.) ultraviolet (UV) laser radiation modifies the response of the surface to subsequent acid etching. A frequency doubled Ar{sup +} laser ({lambda}=244 nm) was used to illuminate the -z crystal face making it resistive to HF etching and thus transforming the illuminated tracks into ridge structures. This process enables the fabrication of relief patterns in a photolithographic manner. Spatially resolved Raman spectroscopy indicates preservation of the good crystal quality after irradiation.

  3. Sensitivity of chemically and electrochemically etched CR 39 polymers to the neutrons of AmBe source

    International Nuclear Information System (INIS)

    Turek, K.; Spurny, F.; Dajko, G.; Somogyi, G.

    1981-01-01

    Seven samples of polymers by different manufacturers were used in a study of the sensitivity of CR 39 polymers to Am-Be neutrons. In the polymer, proton tracks for a relatively broad energy range can also be recorded. The following characteristics were studied: the sample background for different etching methods, the dependence of sensitivity on the etched thickness and on neutron fluence, the effect of type and thickness of external proton emitters, and the effect of the choice of electric parameters on the resulting sensitivity in electrochemical etching. Good results were obtained when chemical and electrochemical etching was used in combination. It was found that with electrochemical etching, sensitivity decreases for neutron fluence exceeding 10 8 cm -2 . The sensitivity of the studied CR 39 polymer samples only little differed. When the most sensitive polymer was used, the minimum dose equivalent in the human body for Am-Be neutrons which could be determined using combination etching was 0.4 mSv (ie., 40 mrems). (B.S.)

  4. Field and laboratory tests of etched track detectors for 222Rn: summer-vs-winter variations and tightness effects in Maine houses

    International Nuclear Information System (INIS)

    Hess, C.T.; Fleischer, R.L.; Turner, L.G.

    1985-01-01

    Effects of tightness of homes of bedrock character on indoor 222 Rn concentrations were sought in 70 homes in the state of Maine by means of four 6- to 8-month-long surveys over a 1.5-yr period. Laboratory experiments were also performed that document the reliability of the track etching system used for the measurements. In this survey the Rn in tight homes was on the average 3.5 times that in drafty ones, and areas with granitic bedrock led to homes having 2.3 times the Rn as for homes on chlorite-biotite-rich bedrock. Winter-to-summer ratios ranged from 0.5-7, and averaged 1.5, implying that surveys of individual homes require a full year of monitoring

  5. Efficiency calibration of solid track spark auto counter

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Liu Rong; Jiang Li; Lu Xinxin; Zhu Tonghua

    2008-01-01

    The factors influencing detection efficiency of solid track spark auto counter were analyzed, and the best etch condition and parameters of charge were also reconfirmed. With small plate fission ionization chamber, the efficiency of solid track spark auto counter at various experiment assemblies was re-calibrated. The efficiency of solid track spark auto counter at various experimental conditions was obtained. (authors)

  6. Effect of certain production parameters and post-production treatments on the etching characteristics of CR-39 sheets

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, G.; Toth-Szilagyi, M.; Hunyadi, I.; Hafez, A.-F.

    1986-01-01

    There is a permanent need in producing track recording detectors of well defined behaviour from CR-39 monomer. Therefore, more studies on the role of production parameters determining the stability of main etching characteristics (bulk etch rate, Vsub(B);etch rate ratio, Vsub(T)/Vsub(B);opaqueness after longer etching periods) are highly required. In our studies we have examined different commercial CR-39 sheets (Homalite, Pershore, MA-ND) to compare their registration sensitivity to selected alpha and proton energies. In addition, we have investigated the main etching parameters of CR-39 sheets manufactured under different casting conditions varying the concentration of initiator and certain additives. Finally, the effect of some post-production treatments, annealing and storage in vacuum, on the Vsub(B) and Vsub(T)/Vsub(B) values is studied.

  7. Migration of 2-butoxyethyl acetate from polycarbonate infant feeding bottles

    DEFF Research Database (Denmark)

    Petersen, Jens Højslev; Lund, K.H.

    2003-01-01

    An enforcement campaign was carried out to assess the migration of 2-butoxyethyl acetate (2-BEA) from polycarbonate infant feeding bottles intended for repeated use. Migration was measured by three successive migration tests into two of the European Union official food simulants: distilled water......-BEA was found from eight of 12 bottles. However, migration above the target value of 0.33 mg kg(-1) was not observed in the third decisive test from any of the 12 different brands of polycarbonate feeding bottles. A migration of between 0.05 and 0.26 mg kg(-1) from seven of 12 bottles was measured...

  8. Fission track dating of zircon: a multichronometer

    International Nuclear Information System (INIS)

    Carpena, J.

    1992-01-01

    Scattering in Fission Track ages of zircons of a single rock is possible when they present morphological and geochemical variations, if the greatest care is not taken in the choice of the etching conditions and the counting of tracks. The Fission Track study of two heterogeneous populations of zircons from the Mont Blanc granite and from the Gran Paradiso gneisses allows to show that zircon may work as a multichronometer

  9. Micromechanisms of fatigue crack growth in polycarbonate polyurethane: Time dependent and hydration effects.

    Science.gov (United States)

    Ford, Audrey C; Gramling, Hannah; Li, Samuel C; Sov, Jessica V; Srinivasan, Amrita; Pruitt, Lisa A

    2018-03-01

    Polycarbonate polyurethane has cartilage-like, hygroscopic, and elastomeric properties that make it an attractive material for orthopedic joint replacement application. However, little data exists on the cyclic loading and fracture behavior of polycarbonate polyurethane. This study investigates the mechanisms of fatigue crack growth in polycarbonate polyurethane with respect to time dependent effects and conditioning. We studied two commercially available polycarbonate polyurethanes, Bionate® 75D and 80A. Tension testing was performed on specimens at variable time points after being removed from hydration and variable strain rates. Fatigue crack propagation characterized three aspects of loading. Study 1 investigated the impact of continuous loading (24h/day) versus intermittent loading (8-10h/day) allowing for relaxation overnight. Study 2 evaluated the effect of frequency and study 3 examined the impact of hydration on the fatigue crack propagation in polycarbonate polyurethane. Samples loaded intermittently failed instantaneously and prematurely upon reloading while samples loaded continuously sustained longer stable cracks. Crack growth for samples tested at 2 and 5Hz was largely planar with little crack deflection. However, samples tested at 10Hz showed high degrees of crack tip deflection and multiple crack fronts. Crack growth in hydrated samples proceeded with much greater ductile crack mouth opening displacement than dry samples. An understanding of the failure mechanisms of this polymer is important to assess the long-term structural integrity of this material for use in load-bearing orthopedic implant applications. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Effects of gamma radiation on country made polycarbonate Durolon FN2200; Efeito da radiacao gama no policarbonato nacional Durolon FN2200

    Energy Technology Data Exchange (ETDEWEB)

    Terence, Mauro Cesar

    1996-07-01

    Type II polycarbonate, PC II, manufactured with high purity reagents as used on medical fabrication was gamma irradiated by {sup 60} Co source with doses from 0 to 300 kGy. Dose effects on the tensile strength at break (TSb) and at yield (TSy), on the molecular weight by viscosity, on optical properties by yellowness index (YI) and transmittance (T), molecular structure by transmission spectroscopy on infrared region (IR). Radical formation and decay at 100 kGy was studied too by electronic paramagnetic resonance (EPR) and nuclear magnetic resonance of proton (NMR {sup 1}H). T S alteration was not observed up to 100 kGy, but molecular weight already suffers alteration at low doses, as well optical properties suffer significant alteration at sterilization doses (25 kGy) by yellowness index of 90% that is not desirable by medical application point of view. Molecular scission degree was calculated from viscosity measurements which value found is 1 and the crosslinking was not observed at sterilization doses. The formation of three different radicals was observed phenoxy, phenyl and isopropyl when irradiated on vacuum and after being put in air contact, scission occurs on PC II on two sites of the polymeric chain, while on PC I scission occurs only in one site. The PC II can be used in sterilized medical devices by gamma radiation from R T point of view, but looking to optical properties in a incorporation of additives will be necessary to cover up this coloration, as an optical whitener. It is interesting to note although PC II has G{sub scission} = 1 and yellowness index of 17% and P C I has G{sub scission} = 16,7 and yellowness index of 27% this difference can be attributed to the large quantity of optical whitener added to PC I. At sterilization doses PC II has an excellent radiolytic stability considering the point of view TS but it is necessary to avoid the yellowness on the fabrication of medical devices that can be radio sterilized. (author)

  11. Effect of electron beam irradiation on the thermal properties of polycarbonate / polyester blend

    International Nuclear Information System (INIS)

    Zarie, K.A.

    2007-01-01

    The effect of electron beam irradiation on the thermal properties of Bayfol (polycarbonate/polyester blend) solid state nuclear track detector (SSNTD) was investigated. Non-isothermal studies were carried out using thermogravimetric analysis (TGA) and differential thermogravimetric (DTG) to obtain the activation energy of thermal decomposition for Bayfol detector. The thermogravimetric analysis (TGA) indicated that the Bayfol samples were decomposed in one main break down stage. Samples of 250 μm thickness sheets were exposed to electron beam irradiations in the dose range 20-600 KGy. The variation of melting temperatures with the electron dose was determined using differential thermal analysis (DTA). The results indicated that the electron irradiation in the dose range 200-600 KGy decreases the melting temperature of the Bayfol samples and this is most suitable for applications requiring the molding of this polymer at lower temperatures

  12. High-density near-field optical disc recording using phase change media and polycarbonate substrate

    Science.gov (United States)

    Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu

    2004-09-01

    We developed a high density near field optical recording disc system with a solid immersion lens and two laser sources. In order to realize the near field optical recording, we used a phase change recording media and a molded polycarbonate substrate. The near field optical pick-up consists of a solid immersion lens with numerical aperture of 1.84. The clear eye pattern of 90.2 GB capacity (160nm track pitch and 62 nm per bit) was observed. The jitter using a limit equalizer was 10.0 % without cross-talk. The bit error rate using an adaptive PRML with 8 taps was 3.7e-6 without cross-talk. We confirmed that the near field optical disc system is a promising technology for a next generation high density optical disc system.

  13. Temperature responsive track membranes

    International Nuclear Information System (INIS)

    Omichi, H.; Yoshido, M.; Asano, M.; Tamada, H.

    1994-01-01

    A new track membrane was synthesized by introducing polymeric hydrogel to films. Such a monomer as amino acid group containing acryloyl or methacryloyl was either co-polymerized with diethylene glycol-bis-ally carbonate followed by on beam irradiation and chemical etching, or graft co-polymerized onto a particle track membrane of CR-39. The pore size was controlled in water by changing the water temperature. Some films other than CR-39 were also examined. (author). 11 refs, 7 figs

  14. Production controls (PC) and technical verification testing (TVT). A methodology for the control and tracking of LILW waste package conditioning

    International Nuclear Information System (INIS)

    Leon, A.M.; Nieto, J.L.L.; Garrido, J.G.

    2003-01-01

    As part of its low and intermediate level radioactive waste (LILW) characterisation and acceptance activities, ENRESA has set up a quality control programme that covers the different phases of radioactive waste package production and implies different levels of tracking in generation, assessment of activity and control of the documentation associated therewith. Furthermore, ENRESA has made available the mechanisms required for verification, depending on the results of periodic sampling, of the quality of the end product delivered by the waste producers. Both processes are included within the framework of two programmes of complementary activities: production controls (PC) and technical verification testing (TVT). (orig.)

  15. Status of development in the field of Cr-39 track detectors

    International Nuclear Information System (INIS)

    Somogyi, G.

    1982-01-01

    The present situation concerning the manufacture and etching characteristics of the CR-39 nuclear track detector is surveyed. Especial attention is paid to the trends in research and to the outstanding questions related to the subject. The requirements and procedures in connection with the manufacture of high-quality, thick and thin detector foils are discussed. The main bulk and track etching characteristics are presented, involving the effects of various environmental parameters as well. A statistical account of the typical directions in application is given. (author)

  16. Controlled nanostructure and high loading of single-walled carbon nanotubes reinforced polycarbonate composite

    International Nuclear Information System (INIS)

    Wang Shiren; Liang Zhiyong; Pham, Giang; Park, Young-Bin; Wang, Ben; Zhang, Chuck; Kramer, Leslie; Funchess, Percy

    2007-01-01

    This paper presents an effective technique to fabricate thermoplastic nanocomposites with high loading of well-dispersed single-walled carbon nanotubes (SWNTs). SWNT membranes were made from a multi-step dispersion and filtration method, and then impregnated with polycarbonate solution to make thermoplastic nanocomposites. High loading of nanotubes was achieved by controlling the viscosity of polycarbonate solution. SEM and AFM characterization results revealed the controlled nanostructure in the resultant nanocomposites. Dynamic mechanical property tests indicated that the storage modulus of the resulting nanocomposites at 20 wt% nanotubes loading was improved by a factor of 3.4 compared with neat polycarbonate material. These results suggest the developed approach is an effective way to fabricate thermoplastic nanocomposites with good dispersion and high SWNT loading

  17. Study of Polymeric Luminescent Blend (PC/PMMA) Doped with Europium Complex under Gamma-Iradiation

    International Nuclear Information System (INIS)

    Parra, D. F.

    2006-01-01

    Spectroscopic properties of blends formed by bisphenol-A polycarbonate (PC) and poly(methyl methacrylate) (PMMA) doped with europium in organic complex were studied. Polymeric luminescent blends are potential materials for many applications; however, little information has been reported concerning the stability under thermal and radiation conditions. Luminescent films were synthesized from europium thenoyltrifluoroacetonate at different concentrations doped in PC/PMMA blends. Films produced of the luminescent polymer blend were irradiated in a 60 C o source. Their luminescent properties, in the solid state, as well as, the thermal oxidative resistance after gamma irradiation was investigated. These systems were characterized by elemental analysis, thermogravimetry (TGA), differential scanning calorimetry (DSC) and infrared spectroscopy (FTIR). Based on TGA data, the thermal stability of PC/PMMA:(tta)3 system is higher than the polymer blend. The DSC results indicated that those new systems are chemically stables. The emission spectra of the Eu 3 +-tta complex doped in the PC/PMMA recorded at 298 and 77 K exhibited the characteristic bands arising from the 5 D 0 →7 F J transitions (J = 0-6). The luminescence intensity decreases with increasing of precursor concentration in the doped polymer obtained by chemical reaction. This result is different from that of samples obtained by physical method in melting doping. The blend was irradiated under ionizing radiation of 60 C o source. After irradiation of the luminescent films the physical properties of luminescence, thermal and oxidative stability were evaluated.(Fapesp and Cnpq financial support)

  18. Radiation dosimetry for microbial experiments in the International Space Station using different etched track and luminescent detectors

    International Nuclear Information System (INIS)

    Goossens, O.; Vanhavere, F.; Leys, N.; De Boever, P.; O'Sullivan, D.; Zhou, D.; Spurny, F.; Yukihara, E. G.; Gaza, R.; McKeever, S. W. S.

    2006-01-01

    The laboratory of Microbiology at SCK.CEN, in collaboration with different universities, participates in several ESA programmes with bacterial experiments that are carried out in the International Space Station (ISS). The main objective of these programmes is to study the effects of space flight conditions such as microgravity and cosmic radiation on the general behaviour of model bacteria. To measure the radiation doses received by the bacteria, different detectors accompanied the microbiological experiments. The results obtained during two space flight missions are discussed. This dosimetry experiment was a collaboration between different institutes so that the doses could be estimated by different techniques. For measurement of the high linear energy transfer (LET) doses (>10 keV μm -1 ), two types of etched track detectors were used. The low LET part of the spectrum was measured by three types of thermoluminescent detectors ( 7 LiF:Mg,Ti; 7 LiF:Mg,Cu,P; Al 2 O 3 :C) and by the optically stimulated luminescence technique using Al 2 O 3 :C detectors. (authors)

  19. Two-year Randomized Clinical Trial of Self-etching Adhesives and Selective Enamel Etching.

    Science.gov (United States)

    Pena, C E; Rodrigues, J A; Ely, C; Giannini, M; Reis, A F

    2016-01-01

    The aim of this randomized, controlled prospective clinical trial was to evaluate the clinical effectiveness of restoring noncarious cervical lesions with two self-etching adhesive systems applied with or without selective enamel etching. A one-step self-etching adhesive (Xeno V(+)) and a two-step self-etching system (Clearfil SE Bond) were used. The effectiveness of phosphoric acid selective etching of enamel margins was also evaluated. Fifty-six cavities were restored with each adhesive system and divided into two subgroups (n=28; etch and non-etch). All 112 cavities were restored with the nanohybrid composite Esthet.X HD. The clinical effectiveness of restorations was recorded in terms of retention, marginal integrity, marginal staining, caries recurrence, and postoperative sensitivity after 3, 6, 12, 18, and 24 months (modified United States Public Health Service). The Friedman test detected significant differences only after 18 months for marginal staining in the groups Clearfil SE non-etch (p=0.009) and Xeno V(+) etch (p=0.004). One restoration was lost during the trial (Xeno V(+) etch; p>0.05). Although an increase in marginal staining was recorded for groups Clearfil SE non-etch and Xeno V(+) etch, the clinical effectiveness of restorations was considered acceptable for the single-step and two-step self-etching systems with or without selective enamel etching in this 24-month clinical trial.

  20. Response of LR-115 type II and CR-39 plastic track detectors to Am-Be and 14.1-MeV neutrons

    International Nuclear Information System (INIS)

    Bradley, D.A.; Chong, C.S.; Saat, Ahmat; Sidik, A.G.; Ghose, A.M.

    1987-01-01

    The fast-neutron response of the plastic LR-115 type II and CR-39 track detectors have been compared, using a 14.1-MeV neutron generator and a radionuclide Am-Be neutron source (effective primary neutron energy 4.5-MeV). The distribution of track diameters for a range of etching times has been evaluated, taking into account track registration efficiency and the relevant fast neutron scattering cross-sections. The efficiency of etched-track formation in LR-115 type II due to neutron irradiation is approximately double that in CR-39. The 14.1-MeV neutrons also tend to produce tracks in both materials with somewhat greater efficiency than do the lower energy neutrons from the radionuclide source, for a given etching time. (author)