WorldWideScience

Sample records for tracer technique estudio

  1. Tracer techniques in microelectronics

    International Nuclear Information System (INIS)

    Flachowsky, J.; Freyer, K.

    1981-01-01

    Tracer technique and neutron activation analysis are capable of measuring impurities in semiconductor material or on the semiconductor surface in a very low concentration range. The methods, combined with autoradiography, are also suitable to determine dopant distributions in silicon. However, both techniques suffer from certain inherent experimental difficulties and/or limitations which are discussed. Methods of tracer technique practicable in the semiconductor field are described. (author)

  2. Tracer techniques in food industry

    International Nuclear Information System (INIS)

    Pertsovskij, E.S.; Sakharov, Eh.V.; Dolinin, V.A.

    1980-01-01

    The appicability of radioactive tracer techniques to process control in food industry are considered. Investigations in the field of food industry carried out using the above method are classified. The 1 class included investigations with preliminary preparation of a radioactive indicator and its following introduction in the system studied. The 2 class includes investigations based on the introduction in the system studied of a non-active indicator which is activated in a neutron flux being in samples selected in or after the process investigated. The 3 class includes studies based on investigations of natural radioactivity of certain nuclides in food stuff. The application of tracer techniques to the above classes of investigations in various fields of food industry and the equipment applied are considered in detail [ru

  3. Principles and techniques of gamma ray tracers

    International Nuclear Information System (INIS)

    Claxton, K.T.

    1978-01-01

    Radioactive tracer techniques provide a very sensitive means of studying physical and chemical processes in a whole variety of different media. Some of the techniques and principles of radioactive tracers and their application to practical engineering systems are discussed. Information which has been found useful in the design of high temperature liquid sodium facilities employing radio-tracers, is presented. The report deals solely with the use of gamma-emitting species as the tracer. These find particular application for in-situ studies on engineering systems where the highly penetrating properties of gamma rays are needed for detection through strongly absorbent media such as stainless steel pepe walls. (author)

  4. Geologic flow characterization using tracer techniques

    International Nuclear Information System (INIS)

    Klett, R.D.; Tyner, C.E.; Hertel, E.S. Jr.

    1981-04-01

    A new tracer flow-test system has been developed for in situ characterization of geologic formations. This report describes two sets of test equipment: one portable and one for testing in deep formations. Equations are derived for in situ detector calibration, raw data reduction, and flow logging. Data analysis techniques are presented for computing porosity and permeability in unconfined isotropic media, and porosity, permeability and fracture characteristics in media with confined or unconfined two-dimensional flow. The effects of tracer pulse spreading due to divergence, dispersion, and porous formations are also included

  5. 15N tracer techniques in pediatric research

    International Nuclear Information System (INIS)

    Heine, W.; Richter, I.; Plath, C.; Wutzke, K.; Stolpe, H.J.; Tiess, M.; Toewe, J.

    1983-01-01

    The main topics of the review comprise mathematical fundamentals of the determination of N metabolism parameters using the 3-pool method, the value of different 15 N tracer substances for the determination of whole-body protein parameters, the utilization of parenterally applied D-amino acids, studies on the influence of different diets on the N metabolism of premature infants with the 15 N tracer technique, the application of the 15 N-glycine-STH-test for the evaluation of the therapeutic effect of STH in children suffering from hypothalamico-hypophyseal dwarfism, in vivo studies on urea utilization by the infant intestinal flora under various dietary regimens as well as in vitro investigations on the utilization of 15 N-labelled urea and NH 4 Cl, resp., by the intestinal flora

  6. Tracer techniques in estimating nuclear materials holdup

    International Nuclear Information System (INIS)

    Pillay, K.K.S.

    1987-01-01

    Residual inventory of nuclear materials remaining in processing facilities (holdup) is recognized as an insidious problem for safety of plant operations and safeguarding of special nuclear materials (SNM). This paper reports on an experimental study where a well-known method of radioanalytical chemistry, namely tracer technique, was successfully used to improve nondestructive measurements of holdup of nuclear materials in a variety of plant equipment. Such controlled measurements can improve the sensitivity of measurements of residual inventories of nuclear materials in process equipment by several orders of magnitude and the good quality data obtained lend themselves to developing mathematical models of holdup of SNM during stable plant operations

  7. A study on the piston ring wear in automotive engine Seat 1500 CA by means of radioactive tracer technique; Estudio del desgaste de segmentos en motor Seat 1500 CA mediante trazadores radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Val Cob, M del; Chul, Y; Fuentes Figuera de Vargas, J.

    1971-07-01

    The iron side wear in the chromium-plated top compression ring has been a matter of interest for the engine makers and it has been required by them to investigate the wear characteristics of the chromium-plated piston ring. Meanwhile, Bureau of Nuclear Energy in Spain (Junta de Energia Nuclear) and Seat Car Manufacturing Company (Sociedad Espanola de Automoviles de Turismo) agreed to study the wear characteristics of chromium-plated piston ring of type CA gasoline engine for Seat 1500 car by means of radioactive tracer technique. (Author) 9 refs.

  8. Suitable activated carbon-13 tracer techniques

    International Nuclear Information System (INIS)

    Zhang Weicheng; Peng Xiuru; Wang Yuhua

    1995-12-01

    Feasibility and applicability studies of the proton induced gamma ray emission (PIGE) have been performed. The graphite was firstly bombarded at various proton energies to determine gamma ray yield (and, thus, sensitivities) for the reaction of interest. The accuracy for the determination of 13 C abundance was checked, and the precision with which this value and ratios 13 C/ 12 C may be obtained was established by repetitive analysis samples. The performance of different standards in this determination was assessed. The mathematical treatment was developed for the determination of 13 C abundance in tracer studies, and to derive the equations that govern this method of analysis from first principles, to arrive finally at a simple expression by virtue of the observed regularities. The system was calibrated by measuring the gamma ray yield form the 12 C (p, γ) 13 N and 13 C(p,γ) 14 N reaction as a function of known 13 C enrichment. Using this experimentally determined calibration curve, unknown materials can be assayed. This technique is applicable to the analysis of samples with 13 C enrichments between 0.1% and 90%. The samples of human breath natural samples were analyzed against graphite and Cylinder CO 2 standards. Relative standard deviations were 13 C abundance, an increase in 13 C per cent isotopic abundance from the natural 1.11% (average) to only 1.39% may be ascertained. Finally, PIGE is compared with more classical techniques for analysis of 13 C tracer experiments. Ease and speed are important advantages of this technique over mass spectrometry, and its error is compatible with the natural variation of biological results. (9 refs., 11 figs., 9 tabs.)

  9. Using radioactive tracer technique in municipal hygiene

    International Nuclear Information System (INIS)

    Yurasova, O.I.

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology

  10. Using radioactive tracer technique in municipal hygiene

    Energy Technology Data Exchange (ETDEWEB)

    Yurasova, O I [Institut Obshchej i Kommunal' noj Gigieny, Moscow (USSR)

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology.

  11. Studies applications through tracers techniques and effluent contaminants dispersing in Montevideo coastal waters and east beaches; Estudio experimental, mediante trazadores, de la dispersion de contaminantes vertidos en la Bahia de Montevideo, en las playas del este de la ciudad

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, R; Dellepere, A; Pintos, A; Barreiro, M; Odino, R; Souto, B; Badano, A [Direccion Nacional de Tecnologia Nuclear, Montevideo (Uruguay); Crosignani, L; Moreno, S [Facultad de Ingenieria. Universidad de la Republica Oriental del Uruguay (Uruguay)

    1995-07-01

    With the purpose to define or not the contamination influence in Montevideo coastal waters, uranine and tritium tracers were injected in outlet river. A higher grade of contamination was found in the Montevideo Bay, and several recommendations were given for the future.

  12. Case study: evaluation of continuos blending silos in the cement industry, by the aid of tracer techniques; Caso de estudio: Evaluacion de silos continuos de homogenizacion en la industria del cemento, utilizando tecnicas de radiotrazadores

    Energy Technology Data Exchange (ETDEWEB)

    Sebastian, C; Maghella, G; Mamani, E [Direccion de Aplicaciones. Instituto Peruano de Energia Nuclear, Lima (Peru)

    2000-12-01

    Besides the actual burning process in cement manufacture, particular importance is attached to raw material preparation and homogenization, not only because of the quality of the kiln fed and therefore of the produced cement, but also because of the economy of the kiln operation, which significantly depends on the uniformity of the chemical composition of the material. As a result, the blending process of the cement raw material, before burning, is a basic stage of cement technology production. In this case, the pneumatic homogenization process is studied in a silo with a great storing and processing capacity. The objective is to evaluate the parameters which influence in the continuos operation. The method allows us to determine the optimal blending parameters, through the observation of the movement and distribution of the different fractions of fine dust raw meal, labelled with La-140 as tracer. Changes in blending according to time are discussed as well as the influence of the silo design on the degree of homogenization. It was showed that the silo blending operation has a strong influence on the production of good-quality cement as well as the implications on energy saving.

  13. Tracer techniques for determination of groundwater flow parameters

    International Nuclear Information System (INIS)

    Drost, W.; Klotz, D.

    1988-05-01

    The most common one-borehole and multiple borehole methods using tracers for the direct determination of the groundwater flow parameters (velocity of flow, flow direction) and for the indirect determination of characteristic quantities of the aquifer (effective porosity, dispersivity, transmissivity) are presented methodically and their value is documented by practical examples. Especially, the properties of and measuring technique with suitable tracers are considered (e.g. T, Na-24, Cr-51, Co-58, Co-60, Br-82, Tc-99, I-125, I-131, Au-198). (orig./HP) [de

  14. Natural stream flow-rates measurements by tracer techniques

    International Nuclear Information System (INIS)

    Cuellar Mansilla, J.

    1982-01-01

    This paper presents the study of the precision obtained measuring the natural stream flow rates by tracer techniques, especially when the system presents a great slope and a bed constituted by large and extended particle size. The experiences were realized in laboratory pilot channels with flow-rates between 15 and 130 [1/s]; and in natural streams with flow-rates from 1 to 25 m 3 /s. Tracer used were In-133m and Br-82 for laboratory and field measurements respectively. In both cases the tracer was injected as a pulse and its dilution measured collecting samples in the measured section, at constant flow-rates, of 5[1] in laboratory experiences and 60[1] of water in field experiences. Precisions obtained at a 95% confidence level were about 2% for laboratory and 3% for field. (I.V.)

  15. Tracer techniques applied to groundwater studies

    International Nuclear Information System (INIS)

    Sanchez, W.

    1975-01-01

    The determination of several aquifer characteristics, primarily in the satured zone, namely: porosity, permeability, transmissivity, dispersivity, direction and velocity of sub-surface water is presented. These techniques are based on artificial radioisotopes utilization. Only field determination of porosity are considered here and their advantage over laboratory measurements are: better representation of volume average, insensibility to local inhomogenities and no distortion of the structure due to sampling. The radioisotope dilution method is used to obtain an independent and direct measurement of the filtration velocity in a water-bearing formation under natural or induced hydraulic gradient. The velocity of the flow is usually calculated from Darcy's formula through the measurement of gradients and requires a knowledge of the permeability of the formation. The filtration velocity interpreted in conjunction with other parameters can, under favourable conditions, provide valuable information on the permeability, transmissibility and amount of water moving through an aquifer

  16. Unit vent airflow measurements using a tracer gas technique

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.G. [Union Electric Company, Fulton, MO (United States); Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); Fleming, K.M. [NCS Corp., Columbus, OH (United States)

    1997-08-01

    An alternative method for assessing flowrates that does not depend on point measurements of air flow velocity is the constant tracer injection technique. In this method one injects a tracer gas at a constant rate into a duct and measures the resulting concentration downstream of the injection point. A simple equation derived from the conservation of mass allows calculation of the flowrate at the point of injection. Flowrate data obtained using both a pitot tube and a flow measuring station were compared with tracer gas flowrate measurements in the unit vent duct at the Callaway Nuclear Station during late 1995 and early 1996. These data are presented and discussed with an eye toward obtaining precise flowrate data for release rate calculations. The advantages and disadvantages of the technique are also described. In those test situations for which many flowrate combinations are required, or in large area ducts, a tracer flowrate determination requires fewer man-hours than does a conventional traverse-based technique and does not require knowledge of the duct area. 6 refs., 10 figs., 6 tabs.

  17. Contribution of the radioactive tracer techniques to the littoral management

    International Nuclear Information System (INIS)

    Alami, R.

    1994-01-01

    The construction of a harbor or its extending, the management of entrance channels and their maintenance (e.g. dredging works), the littoral development for industrial or tourist purposes, the management of urban or industrial rejects are very expensive and have a great impact on the environment, the optimization of which requires to begin with understanding and making sure of the sedimentary mechanisms occurring under the natural conditions. The tracer techniques are, in such cases, a precious tool and a unique help to the decision makers. The profits made by using such techniques in Morocco, which is a seaboard country, have led the C entre National de l'Energie, des Sciences et des Techniques Nucleaires (CNESTEN) to set up a unit which is operational in this field. 7 figs., 8 refs (F.M.)

  18. Need and prospects for using tracer techniques in fruit breeding

    International Nuclear Information System (INIS)

    Zagaja, S.W.

    1975-01-01

    Compared with staple food crops and fodder crops, the commercial value of fruits depends more on their quality than on their productivity. Modified screening techniques are therefore required for fruit crop improvement. The following are areas of fruit crop improvement in which tracer techniques could be used to speed up the progress: assessment of rootstocks and particularly their effect on vigour of growth and productivity of the trees; assessment of mutants productivity; assessment of adaptability to various habitats of fruit tree cultivars and rootstocks; and juvenility studies on fruit trees, aimed at shortening the juvenile stage. On each of these subjects background information is provided and suggestions are made concerning the scope of research. (author)

  19. Tracing salmon to their birthplace by activable tracer technique

    International Nuclear Information System (INIS)

    Shibuya, Masao

    1978-01-01

    Activable tracer technique was applied to trace the recurrent migration of white salmons, as a typical example of employing radioactivation analysis to the study of agricultural and marinefields. Europium was adopted because it is easy to use technically with less influence on fish body and easy to detect, and its remaining time is very long. Artificially hatched young white salmons were stocked in the Saibetsu River after being raised for a month with europium-containing feed. These stocked fish were labeled by fin-cutting method. Recurrent salmons (fin cutting-labeled fish) were then collected and dissected. The fishes were divided into otoliths, scales, flesh, internal organs, gills, bones, etc., and irradiated for 5 min in JRR-2 reactor of Japan Atomic Energy Research Institute. Europium was detected from the scales and otoliths of 3 to 4 year stocked adult fishes by γ-spectrometry of Eu. This proved the availability of activable tracer method for tracing the recurrent migration of salmons. (Kobatake, H.)

  20. Air leakage test of reactor hall using tracer technique

    International Nuclear Information System (INIS)

    Yang Yanqiu; Yang Liang; Yang Tongzai

    2011-01-01

    The leakage ratios of three related reactor halls were tested by sulfur hexafluoride gaseous tracer technique. Moreover, the accumulation intensities of leak gas and its retention time in some important working rooms, the crossroads of corridors and anteroom of the building were detected. The results show that the air leakage ratios of the three reactor halls are (7.30±0.16) x 10 -4 , (1.88±0.12) x 10 -4 and (2.07±0.07) x 10 -4 h -1 . The leak gas accumulates in all the detected working rooms fast, and the retention time to various rooms is about 5 h. The heaviest intensities are in the clothes change rooms on the first floor. However, the retention time to the crossroads and the anteroom is about 10 h, and the accumulation intensities are much small. (authors)

  1. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    International Nuclear Information System (INIS)

    Zhang, Jeff L; Michael Morey, A; Kadrmas, Dan J

    2016-01-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg–Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models. (paper)

  2. Tracer techniques in karst hydrogeology. Application to the location of karst aquifers

    International Nuclear Information System (INIS)

    Mangin, A.; Molinari, J.

    1976-01-01

    From the recent progress in karst aquifer simulation techniques and the improved knowledge of tracers, the old-established tracer technique has become an invaluable instrument for hydrogeological survey work. Typical information obtainable includes karst system boundaries features and location of hydrodynamic discontinuities, flow variation in both space and time. Tracer methods are a basic requirement for investigation of karst groundwater supplies and determining protection zones for water supply points [fr

  3. Mercury bioaccumulation and elimination by Xenomelanires brasiliensis - radioactive tracers technique

    International Nuclear Information System (INIS)

    Malagrino, Waldir; Mesquita, Carlos Henrique de; Sousa, Eduinetty Ceci P.M. de

    2002-01-01

    The present work has as main objective to emphasized the importance of using radioactive tracers as well as to establish a methodology for the utilization of 203 Hg in the bioaccumulation study of mercury by X enomelanires brasiliensis. The exposure time was 168 hours. The bioaccumulation of mercury from the water as well as the elimination of the metal previously absorbed were determined by measuring the activity of 203 Hg, which was added to the water in the beginning of the experiments. The technique chosen is suitable to study the behavior of the stable mercury since the radioisotope used is an isotope of the same element and therefore presents the same chemical properties. The results obtained show that the absorption and elimination of mercury by Xenomelanires brasiliensis is slow, 168 hours being necessary for the elimination of 38 % of the previously absorbed mercury. The results are of main concern if it is considered that the literature about bioaccumulation of mercury by the Brazilian ichthyofauna is scarce. Furthermore the species Xenomelanires brasiliensis is part of the food chain and the results can be used in the evaluation of the potential risk of the mercury bioaccumulation by fishes of higher trophic levels and by men who are the final link of the food chain. (author)

  4. Tracer technique for measuring specific activity of 63 Ni, using 4πβ-γ

    International Nuclear Information System (INIS)

    Iwahara, A.

    1979-01-01

    The specific activity of a 6 3 Ni solution has been measured by an efficiency tracer technique using a 4 π β - γ coincidence system. 6 3 Ni was chosen. Because it's a very low energy pure beta emitter. Due to chemical compatibility and beta spectral shapes, 6 0 Co has been chosen as tracer. In the determination of 6 3 Ni, the specific activity. As the efficiency tracer techniques requires a previous knowledge of tracer activity, this has been measured by a conventional 4 π β -γ coincidence method. (author)

  5. Suitable activated stable nuclide tracer technique and its applications in biology and medicine

    International Nuclear Information System (INIS)

    Zhang Weicheng

    1989-01-01

    Stable isotopes as tracers in biology and medicine have been more extensively used. Mass spectrometry has been a classic technique in the analysis of stable isotopes because it is very sensitive and precise. Activation analysis has recently been introduced as an analytical tool. Its fast speed and simplicity is a great advantage for handling large batches of samples in isotopic tracer experiments. The combination of enriched stable isotope tracer studies and activation analysis techniques has become an ideal and reliable technique, especially in the fields of biology and medicine. This paper presents a survey of the fundamental principle, the character and the applications in biology and medicine for the suitable activated stable isotope tracer techniques

  6. Use of tracer technique in estimation of methane (green house gas) from ruminant

    International Nuclear Information System (INIS)

    Singh, G.P.

    1996-01-01

    Several methods developed to estimate the methane emission by ruminant livestock like feed fermentation based technique, using radioisotope as tracer, respiration chamber, etc. have been discussed. 6 refs., 3 figs

  7. Leak detection and localization in natural and artificial dams using tracer techniques

    International Nuclear Information System (INIS)

    Molinari, J.

    1975-01-01

    Leak detection and localization procedures using often-unknown techniques of identification by natural or artificial tracers are reported. From the analysis of data supplied by natural tracers, or by artificial tracer methods which involve the direct observation of warning phenomena, it is possible to estimate the extent of the infiltrations, define their origin and under certain circumstances determine the main hydrodynamic flow parameters so that their development may be followed. The examples of application and interpretation were taken from the numerous studies carried out in this field by the CEA, where many original investigation methods have been employed [fr

  8. Application of Radionuclide Tracer Techniques in Research on Bio-Effects of Carbon Nanoparticles

    International Nuclear Information System (INIS)

    Zhu Ying; Ran Tiecheng; Li Qingnuan; Xu Jingying; Li Wenxin

    2010-01-01

    There are few effective means to detect and analyze nanomaterials, therefore, radionuclide labeling and tracing techniques play an important role in the studies of interaction between nanoparticles and living systems. This paper briefly summarizes the main results from the application of radionuclide tracer techniques in the studies of interaction between carbon nanoparticles (fullerenes, carbon nanotubes and nano-carbon blacks) and animals and mammalian cells, cites the experimental information on absorption, distribution, metabolism and excretion of nanomaterials, and indicates the signification of these information in the drug development and bio-safety studies of nanomaterials. Based on the novel properties of carbon nanoparticles, the superiority of radionuclide tracer techniques over fluorescent labeling techniques is stressed. It is expected that the radionuclide tracer techniques have an increasing application prospect in the interdisciplinary fields of nanoscience and life science. (authors)

  9. Application of oxygen-18 tracer techniques to arctic hydrological processes

    International Nuclear Information System (INIS)

    Cooper, L.W.; Solis, C.; Kane, D.L.; Hinzman, L.D.

    1993-01-01

    The δ 18 O value of streamflow at Imnavait Creek, Alaska, shifted dramatically from -30.3 per-thousand on 14 May, the first day of streamflow in 1990, to -22.5 per-thousand on 22 May, at the end of the snowmelt. Nevertheless, independent hydrological measurements of snow redistribution by wind, snow ablation, snow and soil mixture content, and snowmelt runoff indicate there cannot be significant mixing of meltwater with underlying ice-rich soils. An alternative explanation is that isotopic fractionation during the phase change from solid to liquid dominates the isotopic variation in streamflow during snowmelt and prevents a straightforward application of 18 O as a conservative hydrological tracer. By contrast, under dry antecedent conditions in late summer, 18 O appeared to be a suitable tracer following rain contributions to streamflow. Streamflow increased as a result of rainfall, but stream isotopic composition did not change until at least two hours after streamflow increased, implicating a wave, or piston-like mechanism for forcing open-quotes oldclose quotes water into the stream channel. Analyses of the stable hydrogen and oxygen isotope composition of various hydrological components within the watershed indicate the importance of evaporation as a dominant factor in the hydrological cycle; soil moisture, alteration as a result of evaporation. The analyses indicate that caution would be advised for any application of stable isotopes to hydrological studies in arctic watersheds. Proportions of snowmelt mixing with underlying soil water may be subject to overestimation because isotopic fractionation as snow melts can be similar in direction and magnitude to the isotopic mixing of snowmelt an soil waters. 40 refs., 7 figs., 1 tab

  10. Leak testing of bubble-tight dampers using tracer gas techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); DuBois, L.J. [Commonwealth Edison, Zion, IL (United States); Fleming, K.M. [NCS Corporation, Columbus, OH (United States)] [and others

    1995-02-01

    Recently tracer gas techniques have been applied to the problem of measuring the leakage across an installed bubble-tight damper. A significant advantage of using a tracer gas technique is that quantitative leakage data are obtained under actual operating differential pressure conditions. Another advantage is that leakage data can be obtained using relatively simple test setups that utilize inexpensive materials without the need to tear ducts apart, fabricate expensive blank-off plates, and install test connections. Also, a tracer gas technique can be used to provide an accurate field evaluation of the performance of installed bubble-tight dampers on a periodic basis. Actual leakage flowrates were obtained at Zion Generating Station on four installed bubble-tight dampers using a tracer gas technique. Measured leakage rates ranged from 0.01 CFM to 21 CFM. After adjustment and subsequent retesting, the 21 CFM damper leakage was reduced to a leakage of 3.8 CFM. In light of the current regulatory climate and the interest in Control Room Habitability issues, imprecise estimates of critical air boundary leakage rates--such as through bubble-tight dampers--are not acceptable. These imprecise estimates can skew radioactive dose assessments as well as chemical contaminant exposure calculations. Using a tracer gas technique, the actual leakage rate can be determined. This knowledge eliminates a significant source of uncertainty in both radioactive dose and/or chemical exposure assessments.

  11. The stream flow rate measurement using tracer techniques at the Kemubu Agricultural Development Authority (KADA), Kelantan

    International Nuclear Information System (INIS)

    Daud Mohammad; Abd Razak Hamzah; Wan Abd Aziz Wan Mohamad; Juhari Yusoff; Wan Zakaria Wan Mohd Tahir

    1985-01-01

    Measuring the flow rate of a water course is one of the basic operations in hydrology, being of general relevance to water problems and of particular importance in the planning of water control schemes. The techniques commonly used in streamflow gauging are either by a current meter of tracer dilution method. This paper describes the latter technique in which radioisotope Tc-99m was used as a tracer in streamflow measurements performed in 1983 in a few selected irrigation canals and pump house under the Kemubu Agriculture Development Authority (KADA), Kelantan. Total count technique and peak-to-peak method were adopted in this study. (author)

  12. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  13. Case study: evaluation of the performance of water treatment units by the use of tracer techniques

    International Nuclear Information System (INIS)

    Sebastian, C.; Maghella, G.; Mamani, E.

    2000-12-01

    Very often, water treatment systems do not reach the expected performance due to disturbances of hydraulic order, which cause malfunctioning in the flow through such systems. Tracer techniques have proved to be very useful to obtain information on the system or a part of it, by means of observation of the released tracer or observation of the released tracer during its progress into the system or at the output of the same. This paper is a report of the behavior of a set of both sand settlement unit and hydraulic flocculators in a potable water plant, through the analysis of radiotracers response curves or residence time distribution curves. The tracers released into the system consists in an aqueous solution of Iodine-131 with very low activity, in order to get a dynamic behave similar to the one of the fluid under investigation

  14. The tracer techniques and the problems in hydrology and sedimentology. 1974 status report

    International Nuclear Information System (INIS)

    Sauzay, G.

    1974-01-01

    Two kinds of nuclear techniques are used in sedimentology. Determination of the sediment mass at a given place using radiometric gages; determination of a sediment mass in motion using nuclear tracer techniques. Some recent applications are described: studies on dredging wastes; study of sedimentation mechanisms in a estuary; study of the possible transport of coarse materials by the swell; adjustement of sedimentological models [fr

  15. Feasibility of a tracer gas technique for containment leakage characterization at Bruce NGS

    International Nuclear Information System (INIS)

    Singh, V.P.

    1985-11-01

    Methods for tracer gas test have been conceived and are proposed for use in conjunction with other techniques used during off-power pressurization tests. During pressurization tests is appears possible to quantify leaks through containment boundaries which make up one of the walls in adjacent rooms but quantification of leaks to open areas will require further development. Several gases may be used as tracers during pressurization tests but the preferred tracer gas is sulphur hexafluoride (SF 6 ) at an in-vault concentration of 100 μL/L if open area sampling is to be carried out of 10 μL/L if only closed room sampling is to be performed. Large values of the ratio (tracer gas concentration in containment/lower detection limit) are necessary for identification of leak sites in open areas having significant ventilation flow. It is recommended that in-station trials be carried out to test the validity of this technique. In addition, a tracer gas technique for use during on-power operation is also proposed but leak site identification and quantification during on-power tests is only possible for containment boundaries which make up the wall(s) of adjacent rooms. The use of SF 6 is required for tests conducted during on-power operation. The recommended in-vault concentration is 10 μL/L. Recommendations are made for future work, including leak tests during on-power operation

  16. Tracer techniques for the study of host-parasite relations

    International Nuclear Information System (INIS)

    Mendgen, K.

    1975-01-01

    Autoradiographic techniques have been used to study the interaction of many facultative and obligate parasites, including viruses. After feeding the host plant with labelled substrates, labelled material accumulates in the infected cells and seems to penetrate into structures of the parasite. After labelling the parasite, its influence on the host may be studied. We use this technique to study the interaction of host (bean) and parasite (bean rust) during the infection process. After infection with uredospores labelled with tritiated orotic acid, the radioactivity is retained almost completely within the young haustorium at 22 h after inoculation. This may indicate a very small influence of the parasite on its compatible host. In incompatible host-parasite combinations, the infection process proceeds in a different way. The use of autoradiographic techniques to compare combinations of varying compatibilities will be discussed. (author)

  17. Bed load determination in Parana river by radioactive tracer technique

    International Nuclear Information System (INIS)

    Aoki, P.E.; Enokihara, C.T.; Rocca, H.C.C.; Bittencourt, A.V.L.

    1988-10-01

    Radioactive tracing technique with marked sand was employed to evaluate the bottom sediment drag of Parana river, near the future site for the ''Ilha Grande'' Dam in Guaira City (State of Parana). 198 Au radioisotope was employed and measurements had been performed for a period of fifteen days. A bed load rate of 952,3 t/day was obtained for a laminar layer of 0,33 m mean thickness and 1.65 m/day mean velocity. (author) [pt

  18. Noninvasive experimental determination of the individual kidney filtration fraction by means of a dual-tracer technique. [/sup 131/I and /sup 99m/Tc tracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Assailly, J.; Pavel, D.G.; Bader, C.; Chanard, J.; Ryerson, T.W.; Cotard, J.P.; Funck-Brentano, J.L.

    1977-07-01

    A noninvasive method for measurement of the individual kidney filtration fraction (FF) is presented, based on an analysis of the early rise of the kidneys' time-activity curves obtained after simultaneous injection of tubular (/sup 131/I) ortho-iodohippurate and glomerular (Tc-99m DTPA) tracers. The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. The dual-tracer technique allows the direct calculation of the ratio of glomerular to tubular clearances, i.e., the FF. In vivo studies were performed on 12 dogs, including normals as well as others with acute ureteral ligation or Benemid-induced tubular blockade. The calculated FF correlated well with the FF obtained from single-shot clearances performed simultaneously. We conclude that the FF can be calculated directly for each kidney, noninvasively, from the early part of the tubular and glomerular time-activity curves by noninvasive external detection.

  19. Radioactive tracer technique in process optimization: applications in the chemical industry

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1989-01-01

    Process optimization is concerned with the selection of the most appropriate technological design of the process and with controlling its operation to obtain maximum benefit. The role of radioactive tracers in process optimization is discussed and the various circumstances under which such techniques may be beneficially applied are identified. Case studies are presented which illustrate how radioisotopes may be used to monitor plant performance under dynamic conditions to improve production efficiency and to investigate the cause of production limitations. In addition, the use of sealed sources to provide information complementary to the tracer study is described. (author)

  20. Radioactive or natural tracer techniques for leak determining of dam abutment

    International Nuclear Information System (INIS)

    Chen Jiansheng; Du Guoping; Zheng Zheng; Sun Jing

    1995-01-01

    Infiltration and localization of preferential infiltration zones at the dam abutment are measured using radioactive tracer tests of flow in boreholes, meanwhile interconnection between boreholes and the observing water points is analysed. The theory and practice of radioactive tracer synthetic detective method are described to give methods and calculation formulae used under the condition of stable flow in single well to measure permeability coefficient and hydrostatic heads. Major single hole techniques including measurement for seepage line, velocity, rate of seepage flow and relationship of recharge of groundwater in aquifers are introduced briefly. The possibilities offered by natural tracers are analysed, including electric-conduct, ph-value and temperature of water as well as stable isotopes (D, 18 O) and tritium. Furthermore, the sensibilities of this theory and methods were confirmed by detecting seepage flow field of Xinanjiang Dam

  1. Potential study of bed filtration characteristics in impressed boreholes by radon tracer technique

    International Nuclear Information System (INIS)

    Litvinov, A.A.; Pinkenzon, D.B.; Makarov, M.S.; Vinarskij, M.S.

    1977-01-01

    Potential study of bed filtration characteristics in impressed boreholes by radon tracer method is shown. Effects recorded by radon tracer result from gamma radiation of short-living radon decay daughter products. During filtration of tracer through punched holes, cement stone, and rocks the products are deposited and cause a local effect for 2-3 hours. There is a shortage of short-living products in filtrated radon liquid and for some time (which is necessary for production of notable quantity of new decay products) it is practically not a gamma emitter. It is shown that the feature of effect formation governs the technique for well logging as well as interpretation of the results obtained

  2. Studies of radioisotope tracer technique and its applications to pesticide sciences in China

    International Nuclear Information System (INIS)

    Jia Minghong; Chen Qing; Zheng Ran

    1996-05-01

    The improper use of chemical pesticides has resulted in serious environmental problems and food pollutions, affecting the ecosystem balance and human being health. There are more and more scientists and research institutions being engaged in the area of radioisotope tracer techniques for pesticide sciences in China. So far, more than 80 labeled compounds, including insecticides, fungicides, acaricides, herbicides, metabolic intermediates, fertilizer and biological agents, etc. have been synthesized at the laboratory for application of isotopes in Institute for Application of Atomic Energy, Chinese Academy of Agricultural Sciences. Over past several years, the great achievements have been made in the researches of radioisotope tracer techniques and their applications to pesticide sciences in China, especially in the researches for isotopic labeling, residues, degradation and metabolism of pesticides in plant and animal, behavior and fate of pesticides in environment, and techniques for safe application of pesticide, and so on. The researches of radioisotope tracer techniques and their applications to pesticide sciences in China in the past years are briefly introduced. Some problems are put forward and the development in future is predicted. (1 tab.)

  3. Recent and ancient recharge deciphered by multi-dating tracer technique

    Science.gov (United States)

    Dogramaci, Shawan; Cook, Peter; Mccallum, Jimes; Purtchert, Roland

    2017-04-01

    Determining groundwater residence time from environmental tracer concentrations obtained from open bores or long screened intervals is fraught with difficulty because the sampled water represents variety of ages. Information on the distribution of groundwater age is commonly obtained by measuring more than one tracer. We examined the use of the multi-tracer technique representing different time frames (39Ar, 85Kr, 14C, 3H, CFC 11- CFC-12 CFC-113, SF6 and Cl,) to decipher the groundwater ages sampled from long screened bores in a regional aquifer in the Pilbara region of northwest Australia. We then applied a technique that assumes limited details of the form of the age distribution. Tracer concentrations suggest that groundwater samples are a mixture of young and old water - the former is inferred to represent localised recharge from an adjacent creek, and the latter to be diffuse recharge. Using our method, we were able to identify distinct age components in the groundwater. The results suggest the presence of four distinct age groups; zero and 20 years, 50 to 100 years, 100 to 600 years and approximately 1000 years old. These relatively high recharge events were consistent with local recharge sources (50-100 years) and confirmed by palaeo-climate record obtained from lake sediments. We found that although the ages of these components were well constrained, the relative proportions of each component was highly sensitive to errors of environmental tracer data. Our results show that the method we implemented can identify distinct age groups in groundwater samples without prior knowledge of the age distribution. The presence of distinct recharge times gives insight into groundwater flow conditions over long periods of time.

  4. Determination of the aerosol filters efficiency by means of the tracer techniques

    International Nuclear Information System (INIS)

    Hirling, J.

    1978-01-01

    Estimation of the nonradioactive methods of filters efficiency determination and tracer techniques are given. The methods are stated and discriptions of the instrumentation for estimation of the filters efficiency are given, in particular: methodology of production of the radioactive synthetic test-aerosols by means of the disperse and steamcondensation aerosol generators; the radio isotope method of the aerosol filters investigations; the methodology of filtartion efficiency determination. The results are given of the radioisotope investigations of filters; properties of the artificial radioactive test-aerosols; characteristics of filters, determined by the tracer techniques. Curves are given for the filtration efficiency of the viscose filtering nozzles of different density depending on the filters load. (I.T.) [ru

  5. Flow-rate measurements in closed-conduits by tracer techniques

    International Nuclear Information System (INIS)

    Lund Plantat, C.

    1982-01-01

    This paper presents the study of the precision obtained measuring flow-rates in closed-conduits by tracer techniques. The flow-rates analyzed were in the range of 10 to 20 l/s and Reynolds numbers from 10 5 to 2 x 10 5 . Tracer used were fluoresceine and In-113 m; and the measurements were performed with the dilution method (punctual and continuous injection) and the Allen method. Precisions for the method of punctual and continuous injections were 6.25% and 9.45% for fluoresceine and 9.3% and 3% for In-113, respectively. For Allen method with In-113 m a precision of 5% was obtained; probably this value was affected by the short distance between detectors. In all cases the error corresponds with the expected value except in one measurement at a 68.3% confidence level. (I.V.)

  6. Radio-tracer techniques in the study of corrosion by molten fluorides; Etude, a l'aide d'indicateurs radioactifs, de la corrosion provoquee par les fluorures fondus; Primenenie metodov radioaktivnykh indikatorov nrn izuchenii korrozii, prichinyaemoj rasplavlennymi ftoristymi soedineniyami; Estudio con indicadores radiactivos de la corrosion ocasionada por fluoruros fundidos

    Energy Technology Data Exchange (ETDEWEB)

    Grimes, W R; Watson, G M; DeVan, J H; Evans, R B [Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1962-03-15

    When Inconel or Inor-8 alloys are exposed to a molten fluoride mixture containing reducible material, chromium is selectively oxidized and removed from the alloy. By the use of radio-tracer Cr{sup 51}, the self-diffusion coefficients for chromium in Inconel and Inor-8 and the applicability of these values to alloys under corrosive conditions have been evaluated. Overall coefficients have been obtained (1) by measuring depletion of Cr{sup 51} (charged as CrF{sub 2}) for non-corrosive fluoride melts in alloy capsules and (2) by comparison of measured total radioactivity of exposed alloy specimens with that of the salt to which they were exposed. In addition, coefficients were obtained from measurement of tracer concentration profiles through successive electropolishings of the specimens. The overall coefficients and those obtained from electropolishing experiments agree very well for Inconel at high temperatures and for Inor-8 at all temperatures. For temperatures below 750{sup o}C, coefficients obtained by electropolishing Inconel specimens are higher than the overall values; the bulk diffusion process is not uniform for this case. In all cases, good agreement was found between the overall diffusion coefficients and those extrapolated from published data at higher temperature with generally similar Cr-Ni alloys. Duplicate, polythermal loops of Inor-8 were used to circulate a non-corrosive fluoride melt containing Cr{sup 51} (as CrF{sub 2}). One of these loops was sacrificed to evaluate take-up of Cr{sup 51} by the alloy; the second was used to circulate a melt containing FeF{sub 2} to obtain measurable removal of Cr from the alloy. Good agreement between observed behaviour and that predicted from the measured diffusion coefficients was obtained; this agreement suggests that the self-diffusion coefficient for Cr is insensitive to changes in chromium content of the Inor-8 alloy. (author) [French] Lorsqu'on soumet les alliages Inconel ou Inor-8 a l'action d'un melange

  7. Some new hydraulic and tracer measurement techniques for heterogeneous aquifer formations

    International Nuclear Information System (INIS)

    Ptak, T.; Teutsch, G.

    1990-01-01

    Groundwater contamination assessment and remediation activities demand reliable techniques for the determination of the governing aquifer parameters and their spatial distribution. In order to define guidelines and recommendations, some existing underground investigation techniques were tested and new methods have been developed as a part of the research program at the Horkheimer Insel experimental field site. In this paper, some new developed field and laboratory techniques are introduced and the results compared for two example monitoring wells located in the northern part of the field site. It is shown that highly conductive and highly heterogeneous aquifers demand high resolution investigation techniques. For transport predictions, new methods are needed that are able to detect preferential flow paths. Results from multilevel tracer tests show that simple analytical interpretations are not valid for this type of aquifer. (Author) (8 refs., 12 figs., tab.)

  8. Application of tracer techniques in studies of sediment transport in Vietnam

    International Nuclear Information System (INIS)

    Hai, P.S.; Quang, N.H.; Xuan, N.M.; Chuong, P.N.; Hien, P.Z.

    1997-01-01

    As a consequence of intensive erosion processes typical of the humid tropical one, as well as of human activities destroying tropical forests, grasslands and protective mangrove swamps, etc, most navigable estuaries in Vietnam suffer seriously from sedimentation. In order to maintain the necessary depth for the 7.000 ton vessels entering and leaving ports, a large amount of money is spent annually on dredging operation. A lot of hydraulic and sedimentary surveys were carried out in the past by different groups of researchers. However, owing to the complexity of sediment processes in estuarine areas under the hydrometeorological conditions typical of the southwest Pacific, the use of just any modelling approach is not suitable. In many cases, the conclusions inferred from mathematical models have been the controversial matter. The tracer techniques, which have been employed in the country since 1991, have provided a very efficient tool to obtain a dynamic idea of sediment transport. Many investigations of bedload transport using Sc-46 labelled glass and Ir-192 glass as radioactive tracers were carried out from 1992 to 1996 at Haiphong harbour area. Bedload transport rates under effect of northeast monsoon and southeast monsoon at 5 zones located on both sides of the navigation channel were estimated. In bedload transport studies, apart from conventional methods for assessment of transport thickness, a new method using the ratio of photoelectric peak to Compton region of spectra acquired directly on the sea bed was put forward and applied. The influence of dredging materials at two dumping sites under different tidal phases on in fill rate in the access channel was assessed by radioactive tracers. The qualitative and quantitative information on sediment transport at some experimental sites given by tracers was used by modelling specialists who have undertaken hydraulic and sedimentary surveys in this region

  9. The tracer technique, an extensive field of application for research and industry

    International Nuclear Information System (INIS)

    Frevert, E.

    1980-10-01

    First the principle of the tracer technique is described. Then the most important applications are reported as there are measurements of velocities of flow and of running through, of charges of amount, of durations and of volumes, investigations of intermixtures, distributions and of corrosion, wear and lubricant phenomenous, locatings of leakages, checkings of tightnesses and determinations of the efficiencies of destilling and purifying plants. For each field of application examples are given, most of them investigations of the DEPARTMENT FOR ISOTOPE APPLICATION of the AUSTRIAN RESEARCH CENTRE SEIBERSDORF Ges.m.b.H. Further applications in chemistry, metallurgy, medicine, biology and agriculture are mentioned. (author)

  10. Application of tracer techniques to the study of trematode infections: Pathological and epidemiological aspects

    International Nuclear Information System (INIS)

    Nansen, P.

    1976-01-01

    Liver fluke and blood fluke infections cause heavy losses in animal production. The infections are characterized by a concomitant anaemia and dysproteinaemia. A review is made of radioisotopic tracer studies which have contributed to an understanding of the dynamic processes underlying the blood changes. Such studies have provided important information about the activity of the parasites, for example, how they cause disease and how they influence animal production. Radioisotopic techniques have also been utilized in the study of free-living fluke larvae. A brief outline of principles and fields if investigations within this area is given. (author)

  11. Buried pipeline leak-detection technique and instruments using radioactive tracers

    International Nuclear Information System (INIS)

    Zhou Shuxuan; Lu Qingqian; Tang Yonghua

    1987-01-01

    For detecting and locating leaks on buried pipelines, a leak-detection technique and related instruments have been developed. Some quantity of fluid mixed with a radioactive tracer is injected. After the pipeline is cleaned, a leak-detector is put into and moves along the pipline to monitor the leaked radioactivity and to record both the radioactive signal and the time signal on a magnetic tape. From the signal curves, it can be judged whether there are any leaks on the pipeline and, if any, where they are

  12. Detection technique of radioactive tracer and its application to the flow problems

    International Nuclear Information System (INIS)

    Sato, Otomaru; Kato, Masao

    1978-01-01

    With a radioactive tracer experiment the nature of the system and the precision are the two key factors to determine the amount of the required tracer. It should be kept as low as possible to meet environmental regulations. The former factor is concerned with the isotope dilution during the experiment and the latter with counting techniques. In part 1, some counting techniques are investigated while three field experiments are described in part 2. Chemical treatments of water sample are described firstly in part 1. Recovery of the order of 95% was achieved with 24 Na, 131 I and 82 Br by either ion exchange or precipitation technique. Three direct γ-ray counting techniques are investigated secondly, e.g. dip counting method, pipe counting technique, and plane source counting technique. Thirdly, counting characteristics of a moving radioactive source was investigated. A small source was stuck on a moving belt and the center of a GM tube was faced to the belt. The counting rates with or without a collimator were analyzed using a simple equation. In part 2, the first experiment is on the flow rate of the Sorachi river in summer 1961. Measurements by an underwater detector and from periodically collected samples were compared at every observing stations. The second experiment was on the sorption loss of the isotopes in the river in 1963. Very little sorption loss was recognized with 82 Br, while a sorption loss of 10% was found with 24 Na after 6 km downflow. Isotopes were found to mix transversely after 7 to 10 km flow. The third experiment is concerned with the investigation on the movement of sediments at Okuma coast in Fukushima prefecture. (J.P.N.)

  13. Study of flow characteristics in a secondary clarifier by numerical simulation and radioisotope tracer technique

    International Nuclear Information System (INIS)

    Kim, H.S.; Shin, M.S.; Jang, D.S.; Jung, S.H.; Jin, J.H.

    2005-01-01

    Numerical simulation in a 2-D rectangular coordinate and experimental study have been performed to figure out the flow characteristics and concentration distribution of a large-scale rectangular final clarifier in wastewater treatment facility located in Busan, S. Korea. The purpose of numerical calculation is to verify the experimentally measured data by radioisotope tracer technique and further to understand the important physical feature occurring in a large-scale clarifier, in many cases which is not sufficient by the aid of limited number of experimental data. To this end, a comprehensive computer program is basically made by SIMPLE algorithm by Patankar with the special emphasis on the parametric evaluation of the various phenomenological models. Calculation results are successfully evaluated against experimental data obtained by the method of radioisotope tracer. Detailed comparison is made on the calculated residence time distribution (RTD) curves with measurement inside the clarifier as well as the exhaust. Further the calculation results predict well the well-known characteristics of clarifier flow such as the waterfall phenomenon at the front end of the clarifier, the bottom density current in the settling zone and the upward flow in the withdrawal zone. Thus it is believed that the flow calculation program and the data incorporation technique of radioisotope measurement employed in this study show the high possibility as a complementary tool of experiment in this area

  14. Water percolation conditions in Ilha Solteira dam (Parana River), using tracer techniques

    International Nuclear Information System (INIS)

    Sanchez, W.; Guidicini, G.; Silva, R.F. da.

    1975-01-01

    Radioisotopic techniques used in the study of water perconlation at the exact place of the construction of the canal lock of Ilha Solteira Dam, in its left side is presented. At the time of the drilling operations, it was discovered, by water leakage tests, total lost at 275,00 level. This water lost occurred at the vicinities of basalt lava-flows. The water leakage tests showed that the total absorption of pumping flow was about 80 liters per minute. To determine the velocity of water percolation in the probable cracks or fractures of the basalt a test of radioactive tracer 131 I was used. For the study of the radioactive tracer behaviour two techniques were tried: measurement of its dilution in the original of the well and the measurement of residence time. Results from the tests showed the existence of a crack or a set of cracks oriented from the radcoisotopic injection well to the artesian wells located at the left shore of Parana river, below Ilha Solteira Dam. The mentioned cracks are localized at the 272,00 level, close tr the contact between the basalt lava-flows

  15. The use of tracer techniques in pesticide balance and metabolism studies

    International Nuclear Information System (INIS)

    Fuehr, F.

    1977-01-01

    The radioisotope tracing technique has been a useful tool in obtaining extensive information on the fate of pesticides in the soil-plant systems, including their uptake, transport and metabolism by plants; their photochemical, chemical and microbial degradation; their adsorption, desorption and translocation in soil; and their bioavailability to untreated crops. A pesticide balance study under practical field conditions using radio labelling can examine a number of factors affecting the fate of a compound at the same time and assess the magnitude of the major processes involved. On the basis of these results, more detailed studies are then formulated to be conducted under an exactly defined environment of a growth chamber or a laboratory. The use of tracer techniques in such studies is reported. (author)

  16. Studies on the electrochemical behaviour of iron by the use of radio-tracer technique, 1. Studies on the electrodeposition and dissolution of iron by the use of radio-tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Moritani, Kimikazu; Ito, Yasuhiko; Kamata, Masahiro; Oishi, Jun

    1984-12-01

    To investigate whether radio-tracer techniques can augment conventional electrochemical techniques, offering useful information about the electrochemical behaviour of iron, the current efficiency of the electrodeposition of iron and the corrosion rate of metallic iron were measured by the radio-tracer method and the results were compared with the results measured by gravimetry and absorption photometry. Major conclusions obtained by the experiments are summarized as: 1) Between ordinary Fe and /sup 59/Fe, no isotope effect was observed. 2) Radiation from /sup 59/Fe had no effect on the electrode reaction. 3) While the use of a Ge semiconductor detector is undoubtedly preferable, Geiger-Mueller counter or NaI(Tl) scintillation counter gave fully satisfactory results. 4) Electrodeposited iron corrodes several times more rapidly than the iron base metal. These results suggests many other interesting applications of the radio-tracer technique when it is desired to obtain more detailed information on the electrochemical behaviour of iron. (author).

  17. Application of isotope tracer technique on the study of the filling and release behavior of carbon nanotubes

    International Nuclear Information System (INIS)

    Wu Shengwei; Guo Jinxue; Li Yan; Li Yulan; Li Wenxin; Liu Shiyuan

    2004-01-01

    The behaviors of washing and release of 110 Ag m -AgNO 3 from carbon nanotubes (CNTs), following soak of opened CNTs in 110 Ag m -AgNO 3 solutions are investigated with the isotope tracer technique. The filled CNTs samples are characterized by HREM, SEM, XRD and EDS. The amount of filled materials is also estimated by the isotope tracer technique. It shows that there are silver materials filled in the CNTs and would not release from the cavities. The results indicate that radioactive tracer is an effective and powerful technique to be applied into study of filling and release behaviors of CNTs as well as estimating the amount of filled materials. (authors)

  18. Determination of hydrogen diffusivity and permeability in W near room temperature applying a tritium tracer technique

    International Nuclear Information System (INIS)

    Ikeda, T.; Otsuka, T.; Tanabe, T.

    2011-01-01

    Tungsten is a primary candidate of plasma facing material in ITER and beyond, owing to its good thermal property and low erosion. But hydrogen solubility and diffusivity near ITER operation temperatures (below 500 K) have scarcely studied. Mainly because its low hydrogen solubility and diffusivity at lower temperatures make the detection of hydrogen quite difficult. We have tried to observe hydrogen plasma driven permeation (PDP) through nickel and tungsten near room temperatures applying a tritium tracer technique, which is extremely sensible to detect tritium diluted in hydrogen. The apparent diffusion coefficients for PDP were determined by permeation lag times at first time, and those for nickel and tungsten were similar or a few times larger than those for gas driven permeation (GDP). The permeation rates for PDP in nickel and tungsten were larger than those for GDP normalized to the same gas pressure about 20 and 5 times larger, respectively.

  19. Tracer techniques for the investigation of wear mechanisms in coated or surface-treated machine parts

    International Nuclear Information System (INIS)

    Goedecke, T.; Grosch, J.

    1990-01-01

    Tracer techniques allow wear measurement down to rates of only some μg/h, and these measurements can be done continuously within an inspection test run, not requiring dismantling of the parts to be examined. The measurements revealed the materials pair of a chilled cast iron camshaft and a hard metal coated rocker arm to be superior in terms of wear behaviour over the materials pair of a malleable cast iron camshaft with induction hardening and a rocker arm with hard chromium plating. The total wear of a chilled cast iron camshaft was measured to be approx. 90% less than that of the malleable cast iron camshaft, under equal loading conditions. With the rocker arms, this ratio is approx. 1:3. Another disadvantage of the latter pair is the overall wear ratio of 19:1. The best wear resistance was measured with a TiN-coated rocker arm combined with a chilled cast iron camshaft. (orig./MM) [de

  20. Measurement of denitrification on grassland using gas chromatography and 15N tracer technique

    International Nuclear Information System (INIS)

    Lippold, H.; Foerster, I.; Hagemann, O.; Matzel, W.

    1981-01-01

    Alternative covering of grassland micro-plots fertilized with 15 NH 4 15 NO 3 allowed on the basis on N 2 and N 2 O quantities released within several weeks to measure denitrification and to calculate it by means of methane as gas tracer. Thus the gas exchange was rendered visible and the N quantities measured could be corrected. In some variants, the acetylene blocking technique was successfully applied by adding acetylene to the soil air. The losses measured at 6 dates are discussed together with the 15 N balance and atmospherical conditions. The method is suited for recording the high losses occurring mainly in the second quarter of the year immediately after fertilization. Under the conditions mentioned soil N losses were small (3 kg N/ha). The immobilized fertilizer N quantities reached 20 to 30 kg/ha (fertilizer rate 100 kg N/ha) and were comparably independent of the date of fertilization. (author)

  1. Application and benefits to industry of radioisotope tracer techniques - an overview

    International Nuclear Information System (INIS)

    Hills, A.E.

    2002-01-01

    Radioisotopes continue to play an important role in better management of natural resources and industrial processes. The success of radioisotope applications is primarily to the ability, conferred by the unique properties of radioactive materials, to collect data, which cannot be obtained by other investigative techniques. Radioisotope-based industrial tracer techniques that have stood the test in their own right are described briefly and certain of the economic and process efficiency impacts are highlighted. The financial and other benefits of this technology, especially in Petrochemical sector have been amply demonstrated and accepted. Typical techniques employed are: Gamma ray scanning of distillation columns, leak testing of heat exchangers, deposit and blockage detection in pipe lines, homogeneous mixing, flow rate measurements and liquid interface measurements. The financial benefits by these techniques are widely accepted to exceed the cost of equipment and studies by several folds. Based on retrospective analysis of the data, it is found that an average cost-benefit ratio of 1:20 in many applications is reasonably representative. (Author)

  2. Techniques necessary for multiple tracer quantitative small-animal imaging studies

    International Nuclear Information System (INIS)

    Sharp, Terry L.; Dence, Carmen S.; Engelbach, John A.; Herrero, Pilar; Gropler, Robert J.; Welch, Michael J.

    2005-01-01

    Introduction: An increasing number and variety of studies on rodent models are being conducted using small-animal positron emission tomography scanners. We aimed to determine if animal handling techniques could be developed to perform routine animal imaging in a timely and efficient manner and with minimal effect on animal physiology. These techniques need to be reproducible in the same animal while maintaining hemodynamic and physiological stability. Methods: The necessary techniques include (a) the use of inhalant anesthesia, (b) arterial and venous cannulation for multiple tracer administrations and blood sampling, (c) development of small-volume analytic columns and techniques and (d) measurement of the physiological environment during the imaging session. Results: We provide an example of a cardiac imaging study using four radiotracers ( 15 O-water, 1-[ 11 C]-acetate, 1-[ 11 C]-palmitate and 1-[ 11 C]-glucose) injected into normal rats. Plasma substrates, CO 2 production and total metabolites were measured. The animals remained anesthetized over the entire imaging session, and their physiological state was maintained. Conclusion: The intrastudy stability of the physiological measurements and substrate levels and interstudy reproducibility of the measurements are reported

  3. Bottom sediment transport by radioactive tracer techniques off a stretch of the southern coast from Sao Paulo State - Brazil

    International Nuclear Information System (INIS)

    Bomtempo, V.L.

    1995-01-01

    This paper presents the methodology and results obtained with radioactive tracer techniques as applied to study sea-bottom sediments movements off a stretch of the southern coast of Sao Paulo State, Brazil, namely Praia do Una. Three injections of ground glass containing Iridium-192 were made and the behaviour of this material was tracked by special detection techniques, as it was acted upon by hydrodynamic agents, in two distinct periods of the year of 1982 (summer and winter). Measurement of hydrodynamic parameters was conducted simultaneously with tracer experiments. From the experiments with radioactive tracers, combined with other conventional studies, qualitative and quantitative conclusions could be drawn, as follows: waves are the prevailing agents in moving bottom sediments; during summer time, onshore and alongshore transport can be identified; during winter time, offshore and alongshore transport are present; for summer conditions, Massif transport rate was estimated to be 150 kg m -1 day -1 . (author). 2 refs, 3 figs

  4. The use of tracer techniques to measure water flow rates in steam turbines

    International Nuclear Information System (INIS)

    Whitfield, O.J.; Blaylock, G.; Gale, R.W.

    1979-01-01

    Radioactive and chemical tracers offer some unique advantages in detailed flow measurement on steam turbine plant. A series of experiments on a nuclear power station are reported where tracers successfully measured water flow rates and the initial steam moisture with an accuracy suitable for performance and commissioning tests. Both radioactive and chemical tracer methods produced identical results. Straightforward practical procedures were evolved that ensured repeatable accuracy and in addition a quantitative method of detecting heater leaks on load was established. (author)

  5. Study of seepage losses from irrigation canals using radioactive tracer technique

    International Nuclear Information System (INIS)

    Ahmad, M.; Tariq, J.A.; Rashid, A.; Rafiq, M.; Iqbal, N.

    2004-06-01

    Pakistan has an intricate irrigation system comprising a huge network of canals. A significant fraction of water in irrigation canals is lost through seepage, which is further responsible for water logging and salinity in some areas. Government is considering lining of irrigation canals to overcome this twin menace. Due to involvement of huge costs, highly pervious sections where the seepage rate is appreciably high, are needed to be identified for planning and execution of remedial actions to eliminate or minimize seepage losses. The conventional methods of measuring seepage rate from canals are limited to 'ponding' and 'inflow-outflow' methods. The ponding method is usually restricted to small canals because of the costly bulkheads and water requirement, unaffordable closure of canal, non representation of the line source and variation in the rate of seepage loss with time due to the sealing effects of fine sediments settling out. Inaccurate measurement of discharge under field conditions and complication due to diversion do not favour the inflow-outflow method. It is believed that the analytical methods represent the most accurate and convenient means of determining seepage values using accurate insitu hydraulic conductivity of the subsoil determined by radiotracer, geometry of the canal and position of the groundwater. As a practical application, radiotracer experiments were carried out at Rakh branch canal near Sukhiki, District Hafizabad (Punjab) to determine groundwater filtration velocity by single well point dilution technique using Technetium-99m (sup 99m/Tc) radioactive tracer, Hydraulic conductivity (determined from filtration velocity and hydraulic gradient) and canal parameters were used in the parametric equation of parachute curve to estimate the seepage rate. The average seepage rate was 4.05 cubic meter per day per meter length of the canal (equivalent to 3.795 cusec per million square feet or 1.157 cumec per second per million square meter of

  6. Multiple stable isotope tracer technique for studying the metabolic kinetics of amino acids in hepatic failure

    Energy Technology Data Exchange (ETDEWEB)

    Zongqin, Xia; Tengchang, Dai; Jianhua, Zhang; Yaer, Hu; Bingyao, Yu; Xingrong, Xu; Guanlu, Huang; Gengrong, Shen; Yaqiu, Zhou; Hong, Yu

    1987-08-01

    In order to study the mechanism of the imbalance of amino acid metabolism during hepatic failure, a stable isotope tracer method for observing simultaneously the metabolic kinetics of several amino acids has been established. /sup 15/N-L-Ala, (2,3-D/sub 3/)-Leu and (2,3-D/sub 3/)-Phe were chosen as nonessential, branched chain and aromatic amino acids. A single iv injection of 40 mg N-Ala, 20 mg deuterated Leu and 20 mg deuterated Phe was given to each human subject. Blood samples were taken just before and at different times (up to 60 min) after the injection. Total free amino acids were isolated from the plasma with a small dowex 50 x 8 column and converted to trifluoroacetyl derivatives. Their abundances were then analyzed with a GC-MS system and typical double exponential time course curves were found for all the three labelled amino acids. A two-pool model was designed and applied for compartmental analysis. Significant changes were found in the kinetic parameters of Phe and Leu in patients with fulminant hepatitis or heptic cirrhosis. The half-lives of both Phe pools were longer and the pool sizes were larger than normal subjects, while the half-lives and pool sizes of Leu changes in the opposite direction. No marked change was found in Ala. The significance of intracellular imbalance of Phe and Leu metabolism was discussed. It is evident that the combination of GCMS technique and multiple-tracers labelled with stable isotopes is of great potential for similar purposes.

  7. An independent method for input accountability in reprocessing plants : magnesium tracer technique for the accountability of plutonium (MAGTRAP)

    International Nuclear Information System (INIS)

    Mathews, C.K.; Jain, H.C.; Chitambar, S.A.; Kavimandan, V.D.; Aggarwal, S.K.

    1975-01-01

    A new technique 'MAGTRAP' for the measurement of the total plutonium in an accountability tank is described which does not require knowledge of either the total volume of solution in the tank or the size of the sample aliquot. The method depends on the addition of natural magnesium as a tracer and the subsequent isotope dilution of an aliquot using a spike with known 26 Mg/ 242 Pu ratio. Using only the isotopic ratios of 26 Mg/ 24 Mg and 239 Pu/ 242 Pu in the mixture, the quantity of the plutonium in the accountability tank can be calculated. In order to correct for magnesium blank, an additional measurement is required before tracer addition. The magnesium tracer technique can also be used to check the volume (or weight) calibration of the tank. Several experiments were carried out in the input accountability tank of the Fuel Reprocessing Plant at Tarapur to assess the accuracy of this method. The weight (or volume) of the solution in the tank could be measured independently with an accuracy of better than 0.5%. An experiment was also conducted to measure the total uranium in the accountability tank using MAGTRAP. The accuracy was better than 1%. The tracer technique was also used to arrive at optimum sparging times to ensure the homogeneity of the solution in the tank. Chemical procedures developed for the separation of plutonium and magnesium from dissolver solutions are also discussed. (author)

  8. Study on chromium speciation in rats by the isotope tracer technique

    International Nuclear Information System (INIS)

    Feng Weiyue; Qian Qinfang; Ding Wenjun; Chai Zhifang

    1999-01-01

    The chromium speciation in the liver cytosol fraction, serum and urine of both normal and diabetic rats are studied by the enriched stable isotope tracer technique combined with the get chromatography and the neutron activating analysis (NAA). The results are as follows: (1) When Cr(III) enters the animal body, it is most likely to be combined with serum proteins. The chromium-protein compound acts as a carrier to transport Cr to the whole body. In the liver cytosol fraction, Cr (III) is also mainly combined with the high molecular weight protein and retains as chromium-protein substance in the liver. (2) A low molecular weight chromium-containing compound is found in all the liver cell cytosol fraction, serum and urine of the two group rats. (3) The diabetic rats lose more amount of low molecular weight of chromium compound in urine than the normal rats do. This might be a main reason to explain why the diabetic rats retain lower Cr in their bodies than the normal group

  9. Energy equivalents of CO2 and their importance in assessing energy expenditure when using tracer techniques

    International Nuclear Information System (INIS)

    Elia, M.

    1991-01-01

    Carbon dioxide production in free living animals and humans can be measured using tracer techniques, but the prediction of energy expenditure also requires an estimate of the energy equivalents of CO2 (energy expended/CO2 produced; EeqCO2). This work is concerned with assessing the variation in EeqCO2 with the use of dietary information, indirect calorimetry, and theoretical concepts. The EeqCO2 for diets (EeqCO2 diet) ingested by 63 individuals living in a Cambridgeshire village, UK, was found to vary by less than 10%. The EeqCO2 diet for different populations varied by greater than 10% and for artificial enteral feeds by approximately 20%. Alcohol increases this variability because it has a particularly high EeqCO2. Variation in the nitrogenous end products of metabolism may also have a substantial effect on the EeqCO2 for a subject (EeqCO2 body), especially when a large proportion of energy expenditure is derived from protein oxidation, as in strict carnivores. Nutrient/energy imbalances such as those associated with growth, hypercaloric feeding, or starvation may also have major effects on EeqCO2 body. It is concluded that the calculation of energy expenditure from CO2 production should not employ a universal value for EeqCO2 body. The value should take into account the physiological and clinical state under investigation. Practical recommendations are suggested

  10. Development Procedure in Mutation Induction and Tracer Technique for Good Agriculture Practices for Under used Crops

    International Nuclear Information System (INIS)

    Faiz Ahmad; Rusli Ibrahim; Khairuddin Abdul Rahim

    2015-01-01

    Under used crops are those crop species which have high potential value in the supply of important raw material for secondary economy sector in food processing. The yield production of new Under used crops varieties can be used as an important input in food production process for export products. The optimum production cost can be minimized since the price of raw material supplied from agriculture sector is cheaper compared with the international markets. Agriculture output can be increased through the development of Under used crops using radiation mutagenesis and tracer technique for good agricultural practices. This paper work will discuss the development procedure of mutation induction method which includes irradiation of samples such as seeds of groundnut and in vitro shoots of banana using gamma rays and application of N-15 for nutrient use efficiency and screening of potential mutant lines with high yield and resistance to drought. These management practices using established procedures of water and nutrient use efficiency will be recommended to the growers. (author)

  11. The NPE gas tracer test and the development of on-site inspection techniques

    International Nuclear Information System (INIS)

    Carrigan, C.; Heinle, R.; Zucca, J.J.

    1995-01-01

    Tracer gases emplaced in or near the detonation cavity of the 1-kiloton Non-Proliferation Event required 1.5 and 13.5 months for sulfur hexaflouride and helium-3, respectively, to reach the surface of Rainier Mesa from an emplacement depth of 400 meters. The sites that first produced tracer gases are those located in known faults and fractures. Numerical modeling suggests that transport to the surface is accomplished within this time frame through atmospheric pumping along high permeability pathways such as fractures. The difference in travel time between the two tracers is due to differences in gas diffusivity and can also be explained by our numerical modeling. (author)

  12. A volatile tracer-assisted headspace analytical technique for determining the swelling capacity of superabsorbent polymers.

    Science.gov (United States)

    Zhang, Shu-Xin; Jiang, Ran; Chai, Xin-Sheng

    2017-09-01

    This paper reports on a new method for the determination of swelling capacity of superabsorbent polymers by a volatile tracer-assisted headspace gas chromatography (HS-GC). Toluene was used as a tracer and added to the solution for polymers swelling test. Based on the differences of the tracer partitioned between the vapor and hydrogel phase before and after the polymer's swelling capacity, a transition point (corresponding to the material swelling capacity) can be observed when plotting the GC signal of toluene vs. the ratio of solution added to polymers. The present method has good precision (RSDpolymers at the elevated temperatures. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. In vivo trace element speciation study by using enriched stable isotopic tracer technique

    International Nuclear Information System (INIS)

    Feng Weiyue; Chai Zhifang; Shi Junwen; Ding Wenjun

    2005-01-01

    In contrast to the radioactive tracer method, the enriched stable isotopic technique used in life sciences will not cause radiation damage to cells and its operation will be no radioactive risk, In our laboratory, the enriched stable isotopes Cr-50, Hg-196 and Hg-198 combined with biochemical separation, neutron activation analysis (NAA) and inductively coupled plasma mass spectrometry (ICP-IVIS) have been used to investigate the element speciation in vivo. Chromium (Cr) is proposed to act as a potentiator of insulin action in animals and human beings. Its deficiency induces the symptoms resembling diabetes and its supplement can alleviate these symptoms. However, as the concentration of Cr in vivo is usually at ultratrace level(- ng/g), its speciation study is usually difficult, since it is almost impossible to avoid the exogenous Cr contamination caused by separation and determination processes. Therefore, in this study, 50 Cr 2 O 3 with 94.2% 50 Cr was used as a tracer combined with gel chromatography to study the Cr speciation in serum, liver, urine and other tissues of healthy and diabetic rats. The Cr concentrations can be determined via 50 Cr(n, γ) 51 Cr by NAA, which is ideally suited for the ultratrace element analyses due to its high precision, accuracy and sensitivity. Such research have found that the most quantity of chromium in vivo is mainly combined with high molecular weight proteins, which is later identified as transferrin and low molecular weight protein is mainly excreted from urine. Mercury is listed by the International Program of Chemical Safety as one of the six most dangerous chemicals in the global environment. Mercury compounds in the environment are often difficult to degrade. However, the mechanism on mercury toxicity to developing children following long term and low dose of mercury exposure is still not clear. Therefore, high sensitive method in vivo needs to be developed to study such low level mercury toxicity to fetus In this

  14. utilization of bio fertilizers and organic sources in arable soils under saline conditions using tracer technique

    International Nuclear Information System (INIS)

    Salama, O.A.E.

    2011-01-01

    Recently, more attention has been paid to conserve and save surrounding environment via minimizing the excessive use of chemical fertilizers and, in general, the agrochemicals applied in heavy quantities in agricultural agroecosystems. Therefore, the attention of most of agronomists was turned towards the use of so called clean agriculture or organic farming. Many of organic systems was pointed out such as the recycling of farm wastes i.e. crop residues, animal manure, organic conditioners for reclamation of soil and in the same time enhancement of plant growth and improving yield quality. The application of organic wastes combined with or without microbial inoculants to plant media are considered as a good management practice in any agricultural production system because it improves, plant quality and soil fertility. Therefore, we have the opportunity to conduct some experiments for achieving the clean agriculture approach, combating the adverse effects of salinity and avoiding the environmental pollution. Series of laboratory and greenhouse experiments were carried out to evaluate the impact of (1) potent isolated fungi (Aspergillus oryzae and Aspergillus terreus) on degrading plant residues (Leucaena and Acacia green parts), and (2) biofertilizers (Sinorhizobium meliloti, Azospirillum brasilense, and Pseudomonas aeruginosa) in assessing barley and spinach plants to combat salinity of soil and irrigation water. 15 N-tracer technique that considered unique and more reliable technique may benefits in clarifying the responsible mechanisms related to plant growth and gave us the opportunity to quantify the exact amounts of N derived from the different sources of nitrogen available to spinach and barley plants grown on sandy saline soil and irrigated with saline water.

  15. Fertilizer-n uptake and distribution in rice plants using 15N tracer technique

    International Nuclear Information System (INIS)

    Yan Juan; Shen Qirong; Yin Bin; Wan Xinjun

    2009-01-01

    Fertilizer-nitrogen (N) uptake and distribution in rice were studied using 15 N tracer technique. The results obtained were as follows. At the tillering, jointing and booting, and anthesis stages, 23.1%, 8.3% and 19.9% of N were taken from fertilizer applied in base (N1), tillering (N2) and jointing and booting (N3), respectively. The 15 N translocation from anthesis to maturity was in the order of N3>N1>N2, but the 15 N translocation efficiency was higher in N1 (base fertilizer treatment) than in the other two treatments. At maturity, the 15 N distribution in straw in the treatments of N1, N2 and N3 was only 24.3%, 26.7% and 30.4%, respectively. No matter what time the N fertilizer was applied, the 15 N uptake was mostly distributed in leaves, then in the sheath, the least in stem, and 15 N distribution in spike increased with the increased 15 N translocation from nutritional organs to spike after anthesis. The study also showed that the 15 N uptake at maturity in N1, N2 and N3 treatments was 10.3%, 5.9% and 12.4%, respectively. The results indicated that (1) when soil N content was not high, the base fertilizer application was important to rice growth, and optimal increment might help increase tillering, and improve rice quality; (2) the initiation fertilizer significantly promoted quantities during grain filling, and thus application of N fertilizer in initiation was of considerable advance in increasing N harvest index (NHI); (3) the rice plants absorbed less N applied in tillering stage due to a big N loss in that period. Therefore a little bit increase of base N fertilizer with no or very small amount of tillering fertilizer, together with some topdressing of N fertilizer during initiation could improve N uptake by rice. (authors)

  16. The use of tracer techniques in the study of soil water flows and contaminant transport

    International Nuclear Information System (INIS)

    Reeves, A.D.; Beven, K.J.

    1990-04-01

    This report reviews the use of different types of tracers in the characterisation of soil water flows and the implications of tracer studies for modelling contaminant transport. The tracers considered are a number of different anions, stable isotopes, radioactive tracers, organic dyes, fluorocarbons, gases, solid particles and water temperature. The theoretical basis for modelling the results of tracer experiments in terms of the traditional convective-dispersion equation (CDE) is outlined. A number of alternative modelling strategies are reviewed: the mobile/immobile water extension of the CDE; the Jury Transfer Function Model (TFM); the Aggregated Mixing Zone (AMZ) model and Random Particle Tracking models. The first will form the basis of the Systeme Hydrologique Europeen (SHE) contaminant transport component. The Jury and AMZ models are both linear models and are consequently limited to applications in which the flows may be considered to be quasi-steady or repeatable. Random particle tracking models have the advantage of both flexibility and applicability to transient and spatially variable flow domains. A random particle model is being implemented on a transputer workstation at Lancaster and will be used to explore the effect of sub-grid scale complexities on effective grid-scale parameter values for distributed models such as SHE. (author)

  17. Application of radioisotope tracer techniques in studies on host-parasite relationships, with special reference to larval trematodes. A review

    International Nuclear Information System (INIS)

    Christensen, N.Oe.

    1981-01-01

    The application of radioisotope tracer techniques in studies on various host-parasite relationships between larval trematodes and their intermediate and definite hosts is reviewed. Such studies comprise, for example, the reproduction and nutrition of various developmental stages of trematodes in relation to host and environment. The preparation and application of radiolabelled larvae are also discussed with special emphasis on their use in studies on free-living ecology and migration in hosts. (author)

  18. Measuring gas-residence times in large municipal incinerators, by means of a pseudo-random binary signal tracer technique

    International Nuclear Information System (INIS)

    Nasserzadeh, V.; Swithenbank, J.; Jones, B.

    1995-01-01

    The problem of measuring gas-residence time in large incinerators was studied by the pseudo-random binary sequence (PRBS) stimulus tracer response technique at the Sheffield municipal solid-waste incinerator (35 MW plant). The steady-state system was disturbed by the superimposition of small fluctuations in the form of a pseudo-random binary sequence of methane pulses, and the response of the incinerator was determined from the CO 2 concentration in flue gases at the boiler exit, measured with a specially developed optical gas analyser with a high-frequency response. For data acquisition, an on-line PC computer was used together with the LAB Windows software system; the output response was then cross-correlated with the perturbation signal to give the impulse response of the incinerator. There was very good agreement between the gas-residence time for the Sheffield MSW incinerator as calculated by computational fluid dynamics (FLUENT Model) and gas-residence time at the plant as measured by the PRBS tracer technique. The results obtained from this research programme clearly demonstrate that the PRBS stimulus tracer response technique can be successfully and economically used to measure gas-residence times in large incinerator plants. It also suggests that the common commercial practice of characterising the incinerator operation by a single-residence-time parameter may lead to a misrepresentation of the complexities involved in describing the operation of the incineration system. (author)

  19. Refining Soil Test Calibration and Nitrogen Recommendation in Corn through 15N Isotope Tracer Technique

    International Nuclear Information System (INIS)

    Rallos, Roland V.

    2015-01-01

    Soil test serve as a baseline to efficiently manage the fertilizer inputs and determine excess nutrients that may cause adverse impact to human health and the environment. The ever increasing fertilizer prices and application inefficiency raised concerns to re-evaluate and redesigned the current crop cultural management to increase its efficiency and productivity. Additionally, with the intensification of farming methods, corn varietal improvement, soil degradations, climate change among many others, the earlier fertilizer recommendations may not be sufficient enough to match with the crop’s fertilizer requirements. The use of 15N isotope tracer techniques in nutrient management research implies important benefits than any existing conventional methodologies. This technology provides enormous advantages because it permits a direct quantitative measurement of the crop nutrient utilization under the influence of varied factors of the environment. Hence, this technique was used to understand N dynamics and fertilizer N-use efficiency (FNUE) in corn grown under different soil fertility levels during wet and dry season productions. This allows us to follow the fate and accurately quantify the contribution of different N pools to the crops N nutrition. Results showed that the fertilizer rates for optimum corn yield under low soil N was observed at 180 kg N ha-1 during dry season while 90 kg N ha-1 during wet season production. While for medium and high N soil, the optimum production yield was noted in 45 kg N ha-1 both in dry and wet season productions. Economic optimum nitrogen recommendations (EONR) were also calculated following the quadratic crop response model. In all cases, EONR for dry season productions are much higher compared to wet season production. Generally, high chlorophyll content was observed at higher fertilizer levels. In addition, more than half of the plant N was taken directly from the added fertilizer during the early stage (30-60 days after

  20. Aluminum metabolism studied by [sup 26]Al tracer using AMS technique

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Koichi (Tokyo Univ. (Japan). Research Center for Nuclear Science and Technology); Yumoto, Sakae; Nagai, Hisao; Hosoyama, Yoshiyuki; Imamura, Mineo; Hotta, Masayoshi; Ohashi, Hideo

    1992-01-01

    By accelerator mass spectrometry (AMS), we studied aluminum metabolism using [sup 26]Al as a tracer. To investigate the role of aluminum toxicity in the etiology of amyotrophic lateral sclerosis (ALS) and Alzheimer's disease, aluminum incorporation into the rat cerebrum was studied. When healthy rats were injected intraperitoneally with [sup 26]Al, a considerable amount of the tracer was incorporated into the brain within only 5 days after the injection. This [sup 26]Al accumulation was apparently irreversible, since it persisted even after 75 days. (author).

  1. Development and evaluation of a tracer-injection hydrothermal technique for studies of waste package interactions

    International Nuclear Information System (INIS)

    Jones, T.E.; Coles, D.G.; Britton, R.C.; Burnell, J.R.

    1986-11-01

    A tracer-injection system has been developed for use in characterizing reactions of waste package materials under hydrothermal conditions. High-pressure liquid chromatographic instrumentation has been coupled with Dickson-type rocking autoclaves to allow injection of selected components into the hydrothermal fluid while maintaining run temperature and pressure. Hydrothermal experiments conducted using this system included the interactions of depleted uranium oxide and Zircaloy-4 metal alloy discs with trace levels of 99 Tc and non-radioactive Cs and I in a simulated groundwater matrix. After waste-package components and simulated waste forms were pre-conditioned in the autoclave systems (usually 4 to 6 weeks), known quantities of tracer-doped fluids were injected into the autoclaves' gold reaction bag at run conditions. Time-sequenced sampling of the hydrothermal fluid providing kinetic data on the reactions of tracers with waste package materials. The injection system facilitates the design of experiments that will better define ''steady-state'' fluid compositions in hydrothermal reactions. The injection system will also allow for the formation of tracer-bearing solid phases in detectable quantities

  2. Studies applications through tracers techniques and effluent contaminants dispersing in Montevideo coastal waters and east beaches

    International Nuclear Information System (INIS)

    Suarez, R.; Dellepere, A.; Pintos, A.; Barreiro, M.; Odino, R.; Souto, B.; Badano, A.; Crosignani, L.; Moreno, S.

    1995-01-01

    With the purpose to define or not the contamination influence in Montevideo coastal waters, uranine and tritium tracers were injected in outlet river. A higher grade of contamination was found in the Montevideo Bay, and several recommendations were given for the future

  3. Study of the effect of Chinese medicine on calcium absorption with isotopic tracer technique

    International Nuclear Information System (INIS)

    Hu, S.M.; Mao, X.Y.; Feng, W.Y.; OY, H.; Wang, M.; Xu, D.D.; Zhang, F.; Chai, Z.F.

    2005-01-01

    The present work was undertaken to study the effect of Chinese medicine on calcium absorption. Female Wistar rats, 3 months old, weighing 250-275 g, were randomly divided into ten groups of 5 rats each. The rats were individually housed in stainless steel metabolic cages in an environmentally controlled room (temperature, 20 degree C; relative humidity, 30%-60%; reversed light : dark cycle, 12:12 hr). Isotopic tracer technique was conducted to study the absorption of calcium acetate and calcium acetate + Chinese medicine in rats. The two calcium supplements were irradiated in a nuclear reactor for 4.95 d at neutron flux of φ=6.1 x 10 13 n/cm 2 ·s. Then they were prepared from concentrated 47 Ca solution (10 mg/ml) with cyclodextrin. The animals received oral doses of 25 mg calcium as calcium acetate or calcium acetate + Chinese medicine via an intragastric gavage. The animals were fasted overnight preceding and food was resumed 3 hrs after the gavage. Blood, heart, lung, liver, spleen, stomach, kidney, small intestine, large intestine and femur samples of the rats were taken upon sacrifice at 0.5, 1, 2, 4, 12, 24, 48, 72, 120, 168 hrs after dosing and assayed for 47 Ca. Urine and feces samples were collected separately after dosing and assayed for 47 Ca. The radioactivity of the samples was counted with a high pure Ge detector and a PC-based Ortec MCA. Its energy resolution was l.85 keV at 1332.5 keV and the relative detection efficiency was 30 %. The dead time was controlled within 10 % to reduce the count loss. Weighed 47 CaCO 3 was used as reference materials. A big distance between the samples and detector was kept to overcome the geometric effect caused by different shape and size of the samples. The gamma energy spectra were analyzed with a multipurpose gamma ray spectrum analysis software package. The parameters were evaluated by means of general linear model, using analysis of covariance with SAS 6.12 for Windows. The results showed that peroral 47 Ca was

  4. Thermoionic emission characteristics of uranium with application to its determination by MSID technique using 233U tracer

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-01-01

    Experimental details of the uranium determination in geological samples (50-1500 ppm range) by mass spectrometric isotope dilution technique (MSID) employing 233 U tracer are presented. For this purpose the thermoionic emission characteristics of uranium in various filament arrangements like simple plane, filament boat, double, are studied and the most efficient one selected for the isotope dilution analysis. The various experimental procedures involved in the MSID like sample dissolution, chemical separation and mass spectrometric analysis are developed and optimised. The experimental results on the uranium determination by MSID with 233 U tracer yielded precision and accuracy of 0,5% and 1% respectively. The importance of the sampling in the precise and accuracy determination of uranium in geological samples, where it is heterogeneously distributed, is discussed. (author) [pt

  5. Study on bioavailability of zinc for children's diet by using activable isotopic tracer 70Zn and neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Zhang Yangmei; Ni Bangfa; Wang Pingsheng; Tian Weizhi; Cao Lei

    2001-01-01

    Bioavailability of zinc for three groups (low amount of diet zinc, balance amount of diet zinc and high amount of diet zinc) of children's diet is studied by using activable isotopic tracer 70 Zn and neutron activation analysis techniques. The results indicate that the fractional absorption of zinc from balance diet zinc group is the highest, up to 33.9%. A procedure of pre-irradiation concentration zinc for fecal samples using anion exchanger is developed, and the enriched 70 Zn with isotopic abundance of 18.3% is used for tracer. The mass ratios between 70 Zn and 68 Zn or 64 Zn and their contents between natural zinc and enriched zinc are used to calculate the bioavailability of zinc. Instrumental neutron activation analysis of 64 Zn of each original fecal samples and pre-irradiation concentrated zinc samples are used to normalize the chemical yield in order to reduce the uncertainty during the chemical separation procedure

  6. Studies on the distribution of 2,4 D herbicide in soil-plant ecosystem using isotope tracer techniques

    International Nuclear Information System (INIS)

    Onal, G.

    1986-01-01

    In this study, distribution of 2,4 Diclorophenoxyacetic acid (2,4 D) herbicide in soil-plant ecosystems under greenhouse conditions were investigated by using isotope tracer techniques. For this purpose barley, wheat and oat plants were grown in two different kinds of soil taken from surrounding of Ankara and the distribution of the herbicide between soil and plants were investigated. In the research 14 C-2,40 D was used and the radioactivity was measured in a liquid scintillation counter. (author)

  7. Study on bioavailability of dietary iron of women by using activable isotopic tracer and neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Zhang Yangmei; Ni Bangfa; Tian Weizhi; Wang Pingsheng; Cao Lei

    2002-01-01

    The bioavailability of diet iron of 10 healthy young women in Beijing area is studied by using two enriched isotopes 54 Fe and 58 Fe, and neutron activation analysis techniques. The abundance of 54 Fe and 58 Fe is 61.4% and 23.4%, respectively. In additional, the atomic absorption spectrometry is employed to measure total iron in fecal samples. Dysprosium, rarely absorbed by human body, is used to monitor the residence time of tracer isotopes in order to collect the fecal samples completely. The results show that the bioavailability of dietary iron in young women is (14.9 +- 3.9)%

  8. Radioimmunoassay of human. beta. -lipotropin in unextracted plasma. [/sup 125/I tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Wiedemann, E. (Univ. of California, Berkeley); Saito, T.; Linfoot, J.A.; Li, C.H.

    1977-11-01

    A sensitive and specific radioimmunoassay for human ..beta..-lipotropin (..beta../sub h/-LPH) in unextracted plasma was developed using pure ..beta../sub h/-LPH as tracer and standard and an antiserum not cross-reacting with human ..beta..-MSH and hACTH. In healthy volunteers plasma ..beta../sub h/-LPH ranged from <20 to 150 pg/ml at 8:00 a.m. and rose after metyrapone administration. ..beta../sub h/-LPH was very low in panhypopituitarism, normal in most patients with untreated Cushing's disease, elevated in acromegaly and extremely high in Nelson's syndrome.

  9. Application of tracer techniques to industrial troubleshooting and environmental pollution control

    International Nuclear Information System (INIS)

    Easey, J.F.

    1994-01-01

    The field applications of tracer technology are reviewed and three specific examples each are given for use of the technology for industrial troubleshooting and for environmental pollution control. Each example examines the background, the experimental details and the result, particularly with regard to the cost benefits. Specific areas covered are: leak studies in a chemical reactor; wear studies in jet aircraft fuel pump, mass balance studies in gold refining; ocean dispersion of iron rich wastes; pollution discharges of mine waste water; and flow patterns and retention times in waste waster treatment lagoons. (author). 18 refs

  10. Application of radioisotope tracer techniques in evaluation of irradiation vessel of flue gas treatment system

    International Nuclear Information System (INIS)

    Joon-Ha Jin; Myun-Joo Lee; Sung-Hee Jung; Young-Chang Nho

    1998-01-01

    The proper design of the irradiation vessel of electron beam flue gases treatment plant and resultant optimum gas flow pattern is a very important factor to get a high removal efficiency of toxic materials from flue gases. Radioisotope tracer experiments were conducted to study the residence time distribution of gas flow in a cylindrical irradiation vessel. A few mCi of gaseous radioisotope tracer Ar-41 was injected to the upstream of the vessel and the input and output response were measured with two NaI scintillation detectors. The same experiment was conducted after the modification of the vessel by introducing 4 baffles. The experimental data were analyzed to calculate mean residence times and mixing characteristics of each system using the residence time distribution (RTD) analysis software. A method to estimate pollutant removal efficiencies of an irradiation vessel from the residence time distributions measured by radiotracer experiments was suggested. The analytical results were compared to evaluate the effect of the baffles on the removal efficiency of the plant

  11. Nitrogen balance and dynamics in corn under different soil fertility levels using “1“5N isotope tracer technique

    International Nuclear Information System (INIS)

    Rallos, R.V.; Rivera, F.G.; Samar, E.D.; Rojales, J.S.; Anida, A.H.

    2015-01-01

    Nitrogen (N) Fertilizer plays a vital role on the growth and development of any crop. The inefficient N fertilizer utilization contributes to poor crop productivity and environment pollution. This study used the 15N isotope tracer technique to understand the nitrogen balance and dynamics in corn grown during the wet and dry season for low, medium and high N soils in Northern Luzon. The experiments were laid out following the randomized complete block design (RCBD) potassium requirements were applied at optimum level on solid chemical analysis and fertilizer recommendation. The study was able to separate the source of N from applied fertilizer and from the soils, traced using 15N during the 30 days after planting (DAP), 60 DAP and at harvest. Result show that, more than half of N in the plant came directly from added fertilizer during the early stage, which decreased towards harvest period. Fertilizer N yield use efficiency showed negative relationship with the rate of N application and soil fertility levels. Of N fertilization in different soil fertility levels were also established using isotope tracer technique. (author)

  12. Statistical atmospheric inversion of local gas emissions by coupling the tracer release technique and local-scale transport modelling: a test case with controlled methane emissions

    Directory of Open Access Journals (Sweden)

    S. Ars

    2017-12-01

    Full Text Available This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping

  13. Statistical atmospheric inversion of local gas emissions by coupling the tracer release technique and local-scale transport modelling: a test case with controlled methane emissions

    Science.gov (United States)

    Ars, Sébastien; Broquet, Grégoire; Yver Kwok, Camille; Roustan, Yelva; Wu, Lin; Arzoumanian, Emmanuel; Bousquet, Philippe

    2017-12-01

    This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping with the distances

  14. Radiological safety methodology in radioactive tracer applications for hydrodynamics and environmental studies; Metodologia de la seguridad radiologica en el empleo de trazadores radiactivos en estudios hidrodinamicos e ingenieria ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Suarez, R; Badano, A; Dellepere, A; Artucio, G; Bertolotti, A [Nuclear Technology National Direction, Montevideo (Uruguay)

    1995-07-01

    The use of radioactive tracer techniques as control sewage disposal contamination in Montevideo Estuarine and Carrasco beach has been studied for the Nuclear Technology National Direction. Hydrodynamic models simulation has been introduced as work methodology. As well as radiological safety and radioactive material applications in the environmental studies has been evaluated mainly in the conclusions and recommendations in this report. maps.

  15. Mode of the absorption of water and nutrients by ascocarps of Tuber melanosporum and Tuber aestivum: a radioactive tracer technique

    International Nuclear Information System (INIS)

    Barry, D.; Staunton, S.; Callot, G.

    1994-01-01

    A simple technique has been developed to study the absorption capacity of the tufts of mycelial filaments, or hyphae, observed on both black and white truffles Tuber melanosporum and Tuber aestivum. These hyphae sprout from the tops of certain scales on the peridium of Tuber. They colonize the surrounding soil and could therefore exploit the nutrients from a large volume of soil. The ability to absorb organic and inorganic nutrients from a source other than the host is a necessary condition for the hypothesis we wished to test, namely that at some stage in its development the truffle ascocarp becomes autonomous. The absorption was demonstrated using autoradiography and liquid scintillation counting. We found that the tufts of hyphae are water permeable ( 3 H 2 O). In addition, they absorb a sugar ([ 14 C]mannose) and an anion ([ 32 P]phosphate). An analysis of our results shows that the spatial distribution of [ 32 P]phosphate is independent of that of tritiated water; the transport of phosphate is therefore not determined by water flux. The quantity and redistribution of the tracer depended on the application site, directly onto the peridium or on a mycelial tuft. The tufts increase the absorption of the tracer and influence its internal redistribution towards accumulation zones. (author)

  16. Tracking the movement and colonization of biocontrol agent Bacillus subtilis using radiolabelling and tracer techniques

    International Nuclear Information System (INIS)

    Kavitha, P.G.; Jonathan, E.I.; Nakkeeran, S.

    2017-01-01

    Bacillus subtilis, an endophytic bacteria that lives inside the plant system is viewed as a potential source of novel genes with antimicrobial activity. B. subtilis strain Bs5 isolated from noni was found to be antagonistic to root knot nematode, Meloidogyne incognitainvitro. The endophytic nature of the bacteria was ascertained by labeling the bacteria with radioactive 32 P and introduced in to the plant system. Autoradiograph of young noni seedlings was developed 28 days after exposure period in the X-ray film. The work was carried out in the Radioisotope Laboratory, Department of Soil Science and Agricultural Chemistry, Tamil Nadu Agricultural University, Coimbatore. Autoradiography indicated a difference in intensity of darkening of photographic emulsion. A closer scrutiny of the autoradiograph showed intensity of the film darkening to be accentuated in the top leaves. It revealed that the radio labelled bacteria effectively translocated from root to shoot and colonized the stem, mid ribs and actively growing regions. From the study it becomes evident that the radio labelling and tracer analysis is an effective tool for tracking the movement and colonization of endophytic bacteria which are potential candidates for combating plant pathogens including plant parasitic nematodes. (author)

  17. Metabolite-balancing techniques vs. 13C tracer experiments to determine metabolic fluxes in hybridoma cells.

    Science.gov (United States)

    Bonarius, H P; Timmerarends, B; de Gooijer, C D; Tramper, J

    The estimation of intracellular fluxes of mammalian cells using only mass balances of the relevant metabolites is not possible because the set of linear equations defined by these mass balances is underdetermined. In order to quantify fluxes in cyclic pathways the mass balance equations can be complemented with several constraints: (1) the mass balances of co-metabolites, such as ATP or NAD(P)H, (2) linear objective functions, (3) flux data obtained by isotopic-tracer experiments. Here, these three methods are compared for the analysis of fluxes in the primary metabolism of continuously cultured hybridoma cells. The significance of different theoretical constraints and different objective functions is discussed after comparing their resulting flux distributions to the fluxes determined using 13CO2 and 13C-lactate measurements of 1 - 13C-glucose-fed hybridoma cells. Metabolic fluxes estimated using the objective functions "maximize ATP" and "maximize NADH" are relatively similar to the experimentally determined fluxes. This is consistent with the observation that cancer cells, such as hybridomas, are metabolically hyperactive, and produce ATP and NADH regardless of the need for these cofactors. Copyright 1998 John Wiley & Sons, Inc.

  18. Technical note: A simple back-mounted harness for grazing dairy cows to facilitate the sulfur hexafluoride tracer gas technique.

    Science.gov (United States)

    van Wyngaard, Josef D V; Meeske, Robin; Erasmus, Lourens J

    2018-03-01

    We describe here a cattle harness to attach a gas collection vessel to facilitate the sulfur hexafluoride (SF 6 ) tracer gas technique. The harness consists of 2 major components: (1) a lightweight, robust body fabricated from an equine surcingle or lunge roller with padded thoracic trapezius pressure points, a bespoke shaping shaft for spine support, and adjustable buckles on both sides; and (2) an elastic flank-strap to prevent the harness from dislodging. The spine support consists of stainless steel laminated with carbon fiber. This support minimizes the contact area with the animal's skin, relieves the spine area of pressure, and creates free flow of ambient air below the platform, reducing sweat accumulation and hence preventing skin lesions. The harness weighs approximately 1.2 kg, allows for attachment of 2 gas collection vessels (animal and background sample), and is cost effective. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Validation of a tracer technique to determine nonsteady-state ketone body turnover rates in man

    International Nuclear Information System (INIS)

    Keller, U.; Sonnenberg, G.E.; Stauffacher, W.

    1981-01-01

    The features of a single-compartment model of total ketone bodies were evaluated using primed constant infusions of [3-14C]acetoacetate (AcAc) and of D-[3-14C]beta-hydroxybutyrate (beta OHB) in 12 postabsorptive subjects. The volume of distribution (VD) of AcAc was 0.18 +- 0.01 liter/kg (n = 9), and that of beta OHB was similar, 0.18 +- 0.02 liter/kg (n = 3). The production rate of total ketone bodies was calculated using the combined specific activity of AcAc and of beta OHB. The mean basal total ketone body production rates were similar using either [14C]AcAc (6.5 mumol . kg-1 . min-1) or [14C]beta OHB (6.8 mumol . kg-1 . min-1). To determine the pool fraction that was rapidly mixed during nonsteady state of ketone body inflow, unlabeled AcAc was infused with stepwise increasing and decreasing rates between 5 and 25 mumol . kg-1 . m-1 to mimic nonsteady-state ketone body production rates. The functional pool fraction P was determined as the pool fraction that provided the best match between tracer-determined rates of ketone production and rates of AcAc infusion. P of total ketone bodies was almost equal to 1 using either [14C]AcAc (1.05 +- 0.16) or [14C]beta OHB (1.00 +- 0.06), suggesting rapid mixing of ketone bodies throughout the entire pool. The described pool model may be used to determine total ketone body kinetics during acute perturbations of the steady state

  20. Tumoral tracers

    International Nuclear Information System (INIS)

    Camargo, E.E.

    1979-01-01

    Direct tumor tracers are subdivided in the following categories:metabolite tracers, antitumoral tracers, radioactive proteins and cations. Use of 67 Ga-citrate as a clinically important tumoral tracer is emphasized and gallium-67 whole-body scintigraphy is discussed in detail. (M.A.) [pt

  1. Report of the project ARCAL XLIII: Paraguay: industrial application of tracer techniques and nuclear control systems

    International Nuclear Information System (INIS)

    Acosta Cabello, Rodolfo

    2000-12-01

    Paraguay needs to improve the productivity in several service industries. Main interest has been devoted to introducing new alternative techniques for the evaluation of the processes of water treatment plants for human consumption and waste waters [es

  2. Implementation and evaluation of the fluorescent tracer technique in greenhouse exposure studies

    NARCIS (Netherlands)

    Bierman, E.P.B.; Brouwer, D.H.; Hemmen, J.J. van

    1998-01-01

    Knowledge of the level of exposure is important for health risk estimation and risk management. Recently, the occurrence of dermal exposure in many situations has been recognized and estimated to be relevant for worker health. Dermal exposure measurement techniques are therefore needed and several

  3. A study on the cycling of phosphorus in wheat (T. alstivum L.) by tracer technique

    International Nuclear Information System (INIS)

    Dwivedi, R.S.

    1974-01-01

    The cycling of phosphorus was studied in relation to its uptake, retention, release and mineralization during the growth period of wheat crop (S. 308) in pure stand (PS) and mixed stand (MS) by using carrier free 32 P. It was estimated that about 60 kg P 2 O 5 /ha was added to the soil through litter by growing two such crops in a year. The mineralization of phosphorus from the litter was to be two times faster at 6 inches soil depth at semi-saturated soil moisture than surface litter. The dry matter production and re-absorption of litter phosphorus by maize plant growing at the bassal dose of decomposed litter were insignificantly different from those of fertilized soils. All the parameters of phosphorus cycling determined by both the techniques did not differ markedly. For mineralization and especially reabsorption studies, only the radiotracer technique appeared to be most sensitive, easy, reliable and quicker. (author)

  4. Nuclear method for determination of nitrogen depth distributions in single seeds. [/sup 14/N tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Sundqvist, B; Gonczi, L; Koersner, I; Bergman, R; Lindh, U

    1974-01-01

    (d,p) reactions in /sup 14/N were used for probing single kernels of seed for nitrogen content and nitrogen depth distributions. Comparison with the Kjeldahl method was made on individual peas and beans. The results were found to be strongly correlated. The technique to obtain depth distributions of nitrogen was also used on high- and low-lysine varieties of barley for which large differences in nitrogen distributions were found.

  5. Determination of solid flow for bottom sediment drag of Parana river using tracer techniques

    International Nuclear Information System (INIS)

    Aoki, Pedro E.; Enokihara, Cyro T.; Rocca, Hector C.C.; Bittencourt, Andre V.L.

    1997-01-01

    Radioactive tracing technique with labeled sand was employed to evaluate the bottom sediment drag of Parana River, near Guaira City, State of Parana. 198 Au radioisotope was used and measurements have been performed for a period of fifteen days. A bed load rate of 914,8 t/day was obtained for a laminar layer of 0,33 mean thickness and 1,65 m/day mean velocity. (author). 5 refs., 7 figs., 3 tabs

  6. Study with liquid and steam tracers at the Tejamaniles area, Los Azufres, Mich., geothermal field; Estudio con trazadores de liquido y vapor en el area Tejamaniles del campo geotermico de Los Azufres, Mich.

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, Eduardo R. [Instituto de Investigaciones Electricas, Gerencia de Geotermia, Cuernavaca, Morelos (Mexico)]. E-mail: iglesias@iie.org.mx; Flores Armenta, Magaly [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico); Torres, Rodolfo J. [Instituto de Investigaciones Electricas, Gerencia de Geotermia, Cuernavaca, Morelos (Mexico); Ramirez Montes, Miguel [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico); Reyes Picasso, Neftali [Instituto de Investigaciones Electricas, Gerencia de Geotermia, Cuernavaca, Morelos (Mexico); Reyes Delgado, Lisette [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico)

    2011-01-15

    The Mexican Federal Commission for Electricity injects brines produced by nearby geothermal wells into well Az-08, located in the Tejamaniles area, in the southwestern portion of Los Azufres, Mich., geothermal field. The main goals of this study are to determine whether or not the injected fluid recharges nine producing wells in the area, and if so, to estimate the fraction of the injected fluid recharging each producing well. Five of the selected wells produce mixes of liquid and steam and the rest produce only steam. For this reason, we designed this study with simultaneous injections of liquid- and steam-tracers. The nine selected producing wells detected the steam-tracer, and the five wells producing mixes detected the liquid-phase tracer. The residence curves of both tracers present a series of peaks reflecting the known fractured nature of the reservoir. The results show the feeding areas of the nine selected wells are recharged by the fluid injected into well Az-08. When this paper was written, the arrival of steam-tracers in all wells was completed, but the wells producing mixes of liquid and steam continued to record the arrival of the liquid-tracer. Until 407 days after injecting the tracer, the total percentage recovery of liquid phase tracer in the five wells producing mixes of liquid and steam was 3.5032%. The arrival of the steam tracer ended in all nine wells 205 days after the tracer was injected, with an overall recovery rate of 2.1553 x 10-2%. The recovery rates imply the recharge rates of the monitored wells by the injector Az-08 are modest, but it appears the amounts of the recovered liquid-phase tracer will increase significantly. The modest recovery rates suggest most of the fluid injected into the well Az-08 disperses in the reservoir, contributing to recharge and maintaining the pressure. Results reveal that: (i) the injected fluid is heated at depths from 700 to over 1000 m, where it boils and rises to reach the feeding areas of the

  7. Evaluating the role of re-adsorption of dissolved Hg{sup 2+} during cinnabar dissolution using isotope tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Ping [Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199 (United States); Li, Yanbin [Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education/Qingdao Collaborative Innovation Center of Marine Science and Technology, Ocean University of China, Qingdao 266100 (China); Liu, Guangliang [Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199 (United States); Southeast Environmental Research Center, Florida International University, Miami, FL 33199 (United States); Yang, Guidi [College of Life Sciences, Fujian Agriculture and Forestry University, Fuzhou 350002 (China); Lagos, Leonel [Applied Research Center, Florida International University, Miami, FL 33199 (United States); Yin, Yongguang [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Gu, Baohua [Environmental Sciences Division, Oak Ridge National Laboratory, Oak Ridge TN 37831 (United States); Jiang, Guibin [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Cai, Yong, E-mail: cai@fiu.edu [Department of Chemistry and Biochemistry, Florida International University, Miami, FL 33199 (United States); Southeast Environmental Research Center, Florida International University, Miami, FL 33199 (United States)

    2016-11-05

    Highlights: • Develop a new method to study Hg re-adsorption in cinnabar. • Both isotope dilution and tracer techniques were adopted. • The presence of O{sub 2} can significantly enhance the dissolution of cinnabar. • Prove the necessity of including re-adsorption in estimating cinnabar dissolution. - Abstract: Cinnabar dissolution is an important factor controlling mercury (Hg) cycling. Recent studies have suggested the co-occurrence of re-adsorption of the released Hg during the course of cinnabar dissolution. However, there is a lack of feasible techniques that can quantitatively assess the amount of Hg re-adsorbed on cinnabar when investigating cinnabar dissolution. In this study, a new method, based on isotope tracing and dilution techniques, was developed to study the role of Hg re-adsorption in cinnabar dissolution. The developed method includes two key components: (1) accurate measurement of both released and spiked Hg in aqueous phase and (2) estimation of re-adsorbed Hg on cinnabar surface via the reduction in spiked {sup 202}Hg{sup 2+}. By adopting the developed method, it was found that the released Hg for trials purged with oxygen could reach several hundred μg L{sup −1}, while no significant cinnabar dissolution was detected under anaerobic condition. Cinnabar dissolution rate when considering Hg re-adsorption was approximately 2 times the value calculated solely with the Hg detected in the aqueous phase. These results suggest that ignoring the Hg re-adsorption process can significantly underestimate the importance of cinnabar dissolution, highlighting the necessity of applying the developed method in future cinnabar dissolution studies.

  8. Tracer-based laser-induced fluorescence measurement technique for quantitative fuel/air-ratio measurements in a hydrogen internal combustion engine.

    Science.gov (United States)

    Blotevogel, Thomas; Hartmann, Matthias; Rottengruber, Hermann; Leipertz, Alfred

    2008-12-10

    A measurement technique for the quantitative investigation of mixture formation processes in hydrogen internal combustion engines (ICEs) has been developed using tracer-based laser-induced fluorescence (TLIF). This technique can be employed to fired and motored engine operation. The quantitative TLIF fuel/air-ratio results have been verified by means of linear Raman scattering measurements. Exemplary results of the simultaneous investigation of mixture formation and combustion obtained at an optical accessible hydrogen ICE are shown.

  9. Xanthine tracers and their preparation

    International Nuclear Information System (INIS)

    Groman, E.V.; Cabelli, M.D.

    1980-01-01

    Compounds useful as tracers in the radioimmunoassay of xanthine derivatives such as theophylline and pharmacologically related drugs are described. They are substituted xanthines in which at least one substituted radical contains radioiodine. The tracers are made by linking radioiodinatable or preradioiodinated radicals to the xanthine derivative which is to be assayed. The tracers may be employed in known radioimmunoassay techniques. (author)

  10. Genetic variations in phosphorus utilization in rice investigation by tracer technique using Phosphorus-32

    International Nuclear Information System (INIS)

    Sanjivkumar, V.; Malarvizhi, P.; Meena, S.; Latha, K.R.

    2012-01-01

    In most soils, soil and fertilizer P are easily bound by either soil organic matter or chemicals and thus are unavailable to plants unless hydrolyzed to release inorganic phosphate. Therefore, the development of P-efficient rice varieties that can grow and yield better with low P supply is a key to improve crop production. P efficient plants play a major role in increasing crop yields due to shortage of inorganic P fertilizer resources, limited land and water resources and increasing environmental concerns. Based on the P uptake efficiency, four rice genotypes were selected from the field experiment and used in pot culture experiment with three levels of P using radio isotope technique to quantify the P acquisition efficiency (PAE) and P use efficiency (PUE) and also to determine the native P supplying power of the soils using 32 P in low P soils. Growth and yield parameters, grain and straw yield and major nutrients uptake of rice genotypes were increased with enhanced level of phosphorus application. Among the four genotypes, TNRH 180 recorded the highest grain yield and uptake. Increasing the P application rate from 25 to 50 kg P 2 O 5 ha -1 increased the %Pdff in grain and straw for all the genotypes. The mean per cent phosphorus utilization (PPU) ranged between 18.74 and 23.72. The PPU of the genotypes followed the order TNRH 180 (23.72 %) > CO08504 (23.36 %) > CO06732 (20.54%) > ADT 47 (18.74%) . The PPU values were higher at lower level of P application (25 kg P 2 O 5 ha -1 ) for the genotypes TNRH 180, CB08504 and CB06732. (author)

  11. Water diffusion in fluoropolymer-based fuel-cell electrolyte membranes investigated by radioactivated-tracer permeation technique

    International Nuclear Information System (INIS)

    Sawada, S.; Yamaki, T.; Asano, M.; Maekawa, Y.; Suzuki, A.; Terai, T.

    2011-01-01

    The self-diffusion coefficient of water, D, in proton exchange membranes (PEMs) based on crosslinkedpolytetrafluoroethylene (cPTFE) films was measured by a radioactivated-tracer permeation technique using tritium labeled water (HTO). The D value was found to increase with the water volume fraction of the PEM, φ, probably because the water-filled regions were more effectively interconnected with each other at high φ, allowing water permeation to be faster through a PEM. Interestingly, the grafted PEMs showed the lower D compared to that of Nafion in spite of their high φ. This would be caused by tortuous structures of transport pathways and a strong coulombic interaction between water and the negatively-charged sulfonate (SO 3 - ) groups. Heavyoxygen water (H 2 18 O) was also used in the similar permeation experiment to obtain the D. Since the HTO diffusion actually occurred not only by translational motion of water but also by intermolecular hydrogen-atom hopping, comparing the D of HTO with that of H 2 18 O was likely to give the information about the state of water in the PEMs. (orig.)

  12. Human ketone body production and utilization studied using tracer techniques: Regulation by free fatty acids, insulin, catecholamines, and thyroid hormones

    Energy Technology Data Exchange (ETDEWEB)

    Keller, U.; Lustenberger, M.; Mueller-Brand, J.G.; Gerber, P.P.; Stauffacher, W.

    1989-05-01

    Ketone body concentrations fluctuate markedly during physiological and pathological conditions. Tracer techniques have been developed in recent years to study production, utilization, and the metabolic clearance rate of ketone bodies. This review describes data on the roles of insulin, catecholamines, and thyroid hormones in the regulation of ketone body kinetics. The data indicate that insulin lowers ketone body concentrations by three independent mechanisms: first, it inhibits lipolysis, and thus lowers free fatty acid availability for ketogenesis; second, it restrains ketone body production within the liver; third, it enhances peripheral ketone body utilization. To assess these effects in humans in vivo, experimental models were developed to study insulin effects with controlled concentrations of free fatty acids, insulin, glucagon, and ketone bodies. Presently available data also support an important role of catecholamines in increasing ketone body concentrations. Evidence was presented that norepinephrine increases ketogenesis not only by stimulating lipolysis, and thus releasing free fatty acids, but also by increasing intrahepatic ketogenesis. Thyroid hormone availability was associated with lipolysis and ketogenesis. Ketone body concentrations after an overnight fast were only modestly elevated in hyperthyroidism resulting from increased peripheral ketone body clearance. There was a significant correlation between serum triiodothyronine levels and the ketone body metabolic clearance rate. Thus, ketone body homeostasis in human subjects resulted from the interaction of hormones such as insulin, catecholamines, and thyroid hormones regulating lipolysis, intrahepatic ketogenesis, and peripheral ketone body utilization. 58 references.

  13. Human ketone body production and utilization studied using tracer techniques: Regulation by free fatty acids, insulin, catecholamines, and thyroid hormones

    International Nuclear Information System (INIS)

    Keller, U.; Lustenberger, M.; Mueller-Brand, J.G.; Gerber, P.P.; Stauffacher, W.

    1989-01-01

    Ketone body concentrations fluctuate markedly during physiological and pathological conditions. Tracer techniques have been developed in recent years to study production, utilization, and the metabolic clearance rate of ketone bodies. This review describes data on the roles of insulin, catecholamines, and thyroid hormones in the regulation of ketone body kinetics. The data indicate that insulin lowers ketone body concentrations by three independent mechanisms: first, it inhibits lipolysis, and thus lowers free fatty acid availability for ketogenesis; second, it restrains ketone body production within the liver; third, it enhances peripheral ketone body utilization. To assess these effects in humans in vivo, experimental models were developed to study insulin effects with controlled concentrations of free fatty acids, insulin, glucagon, and ketone bodies. Presently available data also support an important role of catecholamines in increasing ketone body concentrations. Evidence was presented that norepinephrine increases ketogenesis not only by stimulating lipolysis, and thus releasing free fatty acids, but also by increasing intrahepatic ketogenesis. Thyroid hormone availability was associated with lipolysis and ketogenesis. Ketone body concentrations after an overnight fast were only modestly elevated in hyperthyroidism resulting from increased peripheral ketone body clearance. There was a significant correlation between serum triiodothyronine levels and the ketone body metabolic clearance rate. Thus, ketone body homeostasis in human subjects resulted from the interaction of hormones such as insulin, catecholamines, and thyroid hormones regulating lipolysis, intrahepatic ketogenesis, and peripheral ketone body utilization. 58 references

  14. The choice of label and measurement technique in tracer studies of body protein metabolism in man

    International Nuclear Information System (INIS)

    James, W.P.T.; Sender, P.M.; Garlick, P.J.; Waterlow, J.C.

    1975-01-01

    The turnover of non-serum proteins in man has had limited study despite the physiological importance of maintaining the balance between synthesis and breakdown of body proteins. Body protein is usually considered as a single pool and breakdown rates are often measured by monitoring excreted label at intervals after pulse labelling with radioactive or 15 N amino acids. No label has yet been used for measuring tissue protein breakdown in man which is free from the major problem of label re-utilization. All measurements of breakdown rates, eg. with 75 Se-selenomethionine, 15 N- or 14 C-glycine, give rate constants which are too low. The heterogeneity of body proteins also means that an estimate of the weighted average breakdown rate can only be obtained after following the excretion of isotope for a long period, perhaps of the order of 3-4 half-lives which, for man, would be 100 days after labelling. We therefore use infusions with either 14 C- or 15 N-labelled amino acids to measure breakdown and synthesis rates: these values are less affected by problems of protein heterogeneity. Single injection techniques are subject to more error than constant infusions of label because of the difficulty of defining the precursor activity. 15 N labelling need not be confined to essential amino acids if total protein rather than amino acid turnover is studied: the latter involves measurements of the labelled amino acid itself which is difficult with 15 N because of the small amounts of free amino acid nitrogen available. Carbon labelling of non-essential amino acids is unsuitable for studies of protein turnover and the choice of the position of the label on the molecule is important when labelled essential amino acids are employed. Short-term changes in protein metabolism are evaluated better with amino acids with a small pool size; the equilibration time in the excretory bicarbonate pool is also shorter than in the urea pool so that 15 N is less useful than carbon labelling. We

  15. Use of environmental isotope tracer and GIS techniques to estimate basin recharge

    Science.gov (United States)

    Odunmbaku, Abdulganiu A. A.

    The extensive use of ground water only began with the advances in pumping technology at the early portion of 20th Century. Groundwater provides the majority of fresh water supply for municipal, agricultural and industrial uses, primarily because of little to no treatment it requires. Estimating the volume of groundwater available in a basin is a daunting task, and no accurate measurements can be made. Usually water budgets and simulation models are primarily used to estimate the volume of water in a basin. Precipitation, land surface cover and subsurface geology are factors that affect recharge; these factors affect percolation which invariably affects groundwater recharge. Depending on precipitation, soil chemistry, groundwater chemical composition, gradient and depth, the age and rate of recharge can be estimated. This present research proposes to estimate the recharge in Mimbres, Tularosa and Diablo Basin using the chloride environmental isotope; chloride mass-balance approach and GIS. It also proposes to determine the effect of elevation on recharge rate. Mimbres and Tularosa Basin are located in southern New Mexico State, and extend southward into Mexico. Diablo Basin is located in Texas in extends southward. This research utilizes the chloride mass balance approach to estimate the recharge rate through collection of groundwater data from wells, and precipitation. The data were analysed statistically to eliminate duplication, outliers, and incomplete data. Cluster analysis, piper diagram and statistical significance were performed on the parameters of the groundwater; the infiltration rate was determined using chloride mass balance technique. The data was then analysed spatially using ArcGIS10. Regions of active recharge were identified in Mimbres and Diablo Basin, but this could not be clearly identified in Tularosa Basin. CMB recharge for Tularosa Basin yields 0.04037mm/yr (0.0016in/yr), Diablo Basin was 0.047mm/yr (0.0016 in/yr), and 0.2153mm/yr (0.00848in

  16. Development of in vitro and ex vivo positron-emitting tracer techniques and their application to neurotrauma

    Energy Technology Data Exchange (ETDEWEB)

    Sihver, Sven

    2000-07-01

    The use of positron-emitting tracers has been extended beyond tomographic facilities in the last few years, giving rise to a general positron-emitting tracing technique. The methodological part of the present thesis involved the evaluation of the performance of storage phosphor (SP) plates, with tracers labeled with high-energy, short-lived, positron-emitting radionuclides, using homogenized tissue specimens and autoradiography with frozen brain sections. The SP plates showed superior sensitivity and a linear response over a wide radioactivity range. Autoradiography provided reliable results due to (a) adequate sensitivity for low radioactivity concentration, (b) an excellent linear range, and (c) satisfactory resolution. Though equilibration time of receptor-ligand interaction was dependent upon section thickness, quantification was possible with thinner sections. An initial finding using frozen section autoradiography of rat brain and spinal cord showed preferential binding of [{sup 11}C]4-NMPB, a muscarinic acetylcholine (mACh) receptor antagonist, to the M4 subtype of mACh receptors. Further work to ascertain this specificity, by use of binding studies on cell membranes from CHO-K1 cells expressing individual subtypes of human mACh receptors, suggested lack of subtype selectivity. With respect to the possible clinical use in glutamatergic neuropathology, [{sup 11}C]cyano-dizocilpine, as a potential PET tracer for the N-methyl-D-aspartate (NMDA) subtype of glutamate receptors, was studied. The in vivo visualization of specific binding could not be achieved, though in vitro binding demonstrated good specificity and preferential binding to the activated form of the NMDA receptors. The use of the glucose analogue [{sup 18}F]fluorodeoxyglucose (FDG) to study glucose utilization was evaluated in experimental traumatic brain injury (TBI). A trauma-induced increased uptake of FDG was seen, whereas the uptake of [1-{sup 14}C]glucose remained unchanged. This discrepancy

  17. Study of sensitivity and application of some tracers of use in hydrologic works; Estudio de sensibilidad y aplicacion de algunos trazadores de empleo en trabajos hidrologicos

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, M C [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1980-05-15

    Inside the Industrial Applications Management, particularly in the Hydrology department, in the ININ outlined diverse problems are had in the study of underground waters and surface waters that either in a particular way, or in inter institutional collaboration (SARH, CFE, UNAM) it seen the necessity to solve this problem in the interconnection aspects in aquifer, expenses and contamination. One of the medullary parts that are had in this study is the applied evaluation of the tracer one that it presents two general aspects: a) determination method and b) Applicability depending on the land type that one has in the current to be applied. This study seeks according to: the sensibility reached with each one, and the evaluation of some other parameters like used time, cost and mainly realization feasibility at field level, to present some alternative for the use of them. (Author)

  18. Measurement of open streams by using tracers

    International Nuclear Information System (INIS)

    Ramos, German F.; Tarquino, W.; Curcuy, H.; Orozco, C.

    1999-01-01

    This paper presents an intercomparison study to be carried out between flux measurements by using tracers and moulinet. This intercomparison is scheduled to be performed at the measurement station belonging to the National Service of Meteorology and Hydrology (SENAMHI). Two techniques of tracer dilution are outstanded: total evaluation with tracer punctual injection and punctual evaluation with tracer continuous injection. Total evaluation with tracer punctual injection has been used since this technique is considered to be more suitable for hydrology purposes

  19. Tracer theory

    International Nuclear Information System (INIS)

    Margrita, R.

    1988-09-01

    Tracers are used in many fields of science to investigate mass transfer. The scope of tracers applications in Service of Applications Radioisotopes (S.A.R.-France) is large and concerns natural and industrial systems such as Sciences of earth: hydrology - civil engineering - Sedimentology - environmental studies. Industrial field: chemical engineering - mechanical engineering. A general tracer methodology has been developed in our laboratories from these different applications fields and this paper shows these different points of view in using tracers; our wish is that the methods used in an experimental field can be employed in an another one

  20. Suitability of tracers

    International Nuclear Information System (INIS)

    Klotz, D.

    1999-01-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other [de

  1. Movement of iodine and rain water from the atmosphere to the plant - soil - water system by the activable tracer techniques

    International Nuclear Information System (INIS)

    Yuita, Kouichi

    1996-01-01

    Iodine is one of the important elements in the environmental and agricultural sciences. It is requested to elucidate the long-term behavior of iodine in the atmosphere - soil·plant - soil water system. We developed the new tracer method, in which iodine released into the atmosphere from the stack of iodine manufacturing plant in Chiba prefecture was used as the activable tracer. Using this method, we traced the direct deposition of iodine in atmosphere onto the plant tops and the penetration of fallout iodine into soil in an open air over a long period. A quantitative evaluation of recharge function of water resources in agricultural and forest lands of Japan was eagerly requested from the nation. For it, we developed the new Br - tracer method combined with the soil water sampling system with the alumina porous ceramic cup. This tracer method was successfully applied to the agricultural and forest land in the catchment area of Sakawa river in Kanagawa prefecture. And the infiltration rate of the rain water and irrigation water, from the soil surface to the dept of 3m of the soil horizon in the forest land, tea garden and paddy field was quantitatively measured during two years. (J.P.N.)

  2. Nitrogen use efficiency evaluation of aerobic rice under field capacity water potential using {sup 15}N isotopic tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Wahid, Ahmad Nazrul Abd, E-mail: a-nazrul@nuclearmalaysia.gov.my [Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, 43600, Selangor (Malaysia); Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia); Rahim, Sahibin Abd, E-mail: haiyan@ukm.edu.my [Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi, 43600, Selangor (Malaysia); Rahim, Khairuddin Abdul; Harun, Abdul Rahim [Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2015-09-25

    This study was carried out to evaluate the efficiency use of the nitrogen fertilizer on aerobic rice varieties MR219-4 and MR219-9 which were grown aerobically under field capacity water potential at the controlled environment area or shield house. Direct {sup 15}N isotope tracer method was used in this study, whereby the {sup 15}N isotope was utilized as a tracer for nitrogen nutrient uptake. {sup 15}N isotope presence in the samples is determined by using emission spectrometer analysis and percentage of total nitrogen is determined by using Kjeldahl method. {sup 15}N atom access value contained in the sample will be used in determining the effectiveness of the use of nitrogen in fertilizers through the specific calculation formulas. In this work, the data several data of nitrogen derived from fertilizer (Ndff), total nitrogen, nitrogen uptake and nitrogen use efficiency was obtained.

  3. Nitrogen use efficiency evaluation of aerobic rice under field capacity water potential using 15N isotopic tracer technique

    International Nuclear Information System (INIS)

    Wahid, Ahmad Nazrul Abd; Rahim, Sahibin Abd; Rahim, Khairuddin Abdul; Harun, Abdul Rahim

    2015-01-01

    This study was carried out to evaluate the efficiency use of the nitrogen fertilizer on aerobic rice varieties MR219-4 and MR219-9 which were grown aerobically under field capacity water potential at the controlled environment area or shield house. Direct 15 N isotope tracer method was used in this study, whereby the 15 N isotope was utilized as a tracer for nitrogen nutrient uptake. 15 N isotope presence in the samples is determined by using emission spectrometer analysis and percentage of total nitrogen is determined by using Kjeldahl method. 15 N atom access value contained in the sample will be used in determining the effectiveness of the use of nitrogen in fertilizers through the specific calculation formulas. In this work, the data several data of nitrogen derived from fertilizer (Ndff), total nitrogen, nitrogen uptake and nitrogen use efficiency was obtained

  4. Study on development of evaluation technique of in-situ tracer test in Horonobe Underground Research Laboratory project (Contract research)

    International Nuclear Information System (INIS)

    Yokota, Hideharu; Amano, Kenji; Maekawa, Keisuke; Kunimaru, Takanori; Naemura, Yumi; Ijiri, Yuji; Motoshima, Takayuki; Suzuki, Shunichi; Teshima, Kazufumi

    2013-06-01

    In the Horonobe Underground Research Laboratory Project, in-situ tracer tests are valuable and important as the investigations to obtain the mass transportation data of fractures in hostrock. However, it is difficult that the in-situ tests are executed under various conditions due to long test period and the tests results are evaluated about permeable heterogeneity in a fracture and/or scale effects. In this study, a number of tracer tests are simulated in a fictitious single plate fracture generated on computer. And the transport parameters are identified by fitting one- and two-dimensional models to the breakthrough curves obtained from the simulations in order to investigate the applicability of these models to the evaluation of in-situ tracer test. As a result, one-dimensional model yields larger longitudinal dispersion length than two-dimensional model in the both cases of homogeneous and heterogeneous hydraulic conductivity fields of the fictitious fracture. This is because that the effect of transverse dispersion has to be included in the longitudinal dispersion length parameter in the one-dimensional model. It is also found that the larger dipole ratio and the larger natural groundwater flow crossing the flow generated between two boreholes make the identified longitudinal dispersion length larger. And, the longitudinal dispersion length identified from a tracer test is smaller and/or larger than the macroscopic longitudinal dispersion length identified from whole fracture. It is clarified that these are occurred by shorter or longer distance between boreholes compare to the correlation length of geostatistical heterogeneity of fictitious fracture. (author)

  5. Development of radioisotope tracer technology

    International Nuclear Information System (INIS)

    Jin, Joon Ha; Lee, Myun Joo; Jung, Sung Hee; Park, Soon Chul; Lim, Dong Soon; Kim, Jae Ho; Lee, Jae Choon; Lee, Doo Sung; Cho, Yong Suk; Shin, Sung Kuan

    2000-04-01

    The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and to build a strong tracer group to support the local industries. In relation to the tracer technology in 1999, experiments to estimate the efficiencies of a sludge digester of a waste water treatment plant and a submerged biological reactor of a dye industry were conducted. As a result, the tracer technology for optimization of facilities related to wastewater treatment has been developed and is believed to contribute to improve their operation efficiency. The quantification of the experimental result was attempted to improve the confidence of tracer technology by ECRIN program which basically uses the MCNP simulation principle. Using thin layer activation technique, wear of tappet shim was estimated. Thin layer surface of a tappet shim was irradiated by proton beam and the correlation between the measured activity loss and the amount of wear was established. The equipment was developed to adjust the energy of proton which collides with the surface of tappet. The tracer project team has participated into the tracer test for estimating the efficiency of RFCC system in SK cooperation. From the experiment the tracer team has obtained the primary elements to be considered for judging the efficiency of RFCC unit. By developing the tracer techniques to test huge industrial units like RFCC, the tracer team will be able to support the local industries that require technical services to solve any urgent trouble. (author)

  6. Environmental Tracers

    Directory of Open Access Journals (Sweden)

    Trevor Elliot

    2014-10-01

    Full Text Available Environmental tracers continue to provide an important tool for understanding the source, flow and mixing dynamics of water resource systems through their imprint on the system or their sensitivity to alteration within it. However, 60 years or so after the first isotopic tracer studies were applied to hydrology, the use of isotopes and other environmental tracers are still not routinely necessarily applied in hydrogeological and water resources investigations where appropriate. There is therefore a continuing need to promote their use for developing sustainable management policies for the protection of water resources and the aquatic environment. This Special Issue focuses on the robustness or fitness-for-purpose of the application and use of environmental tracers in addressing problems and opportunities scientifically, to promote their wider use and to address substantive issues of vulnerability, sustainability, and uncertainty in (groundwater resources systems and their management.

  7. Proposal for a coordination research programme (CRP) of the International Atomic Energy Agency (IAEA) on stable isotope tracer techniques for studies on protein-energy interactions

    International Nuclear Information System (INIS)

    Shetty, P.; James, W.P.T.

    1993-01-01

    This Report provides a rationale and justification for the initiation of a Coordinated Research programme to support studies using stable isotopic tracer techniques to address priority areas of human protein-energy interactions with special emphasis on the problems of human nutrition in developing countries. The Report suggests a modus for establishing such a practically oriented Coordinated Research Programme under the aegis of the International Atomic Energy Agency with concrete suggestions for its organization and the identification of probable participants in such a programme. The likely sources of additional funding to sustain such an activity viable for a period of 4 to 5 years are also indicated. 8 refs

  8. Journal: Efficient Hydrologic Tracer-Test Design for Tracer ...

    Science.gov (United States)

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed to facilitate the design of tracer tests by root determination of the one-dimensional advection-dispersion equation (ADE) using a preset average tracer concentration which provides a theoretical basis for an estimate of necessary tracer mass. The method uses basic measured field parameters (e.g., discharge, distance, cross-sectional area) that are combined in functional relatipnships that descrive solute-transport processes related to flow velocity and time of travel. These initial estimates for time of travel and velocity are then applied to a hypothetical continuous stirred tank reactor (CSTR) as an analog for the hydrological-flow system to develop initial estimates for tracer concentration, tracer mass, and axial dispersion. Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be necessary for descri

  9. Vitamin B 12 absorption: correction of intestinal retention by whole-body profile activity of vitamin B 12-58 cobalt and by double tracer technique

    International Nuclear Information System (INIS)

    Goncalves, M.R. Bencke; Gheldof, R.; Paternot, L. van Tricht; Delmotte, E.; Verschaeren, A.; Martin, P.; Verhas, M.; Universidade Federal, Rio de Janeiro, RJ

    1997-01-01

    Full text. Intestinal retention could give false negative results in determining the whole-body retention of vitamin B 12 absorption (WBC B12-58Co). After having validate the WBC B12-58Co, taking the Schilling test as reference, we have studied the feasibility to evaluate the intestinal contamination by measurement of the profile activity distribution of vitamin B12-58Co and by a double tracer technique (WBC B12-58Co/ WBC 51 Cr Cl3). Methodology: twenty five patients were studied for the setting up of the new methodology. For eleven of them the WBC B12-58 Co retention was measured at the 7th day after the oral administration of 37KBq of B12-58Co using a four detectors whole body counter. One week later, a Schilling test was performed after the oral absorption of 18,5 KBq B12-57Co. Results were expressed as %ID. In these patients, one single peak of hepatic activity was observed on the whole body profile and thus no further intestinal correction was needed. In order to evaluate the intestinal contribution, we made in nine other patients the profile of the whole body distribution of activity at 1 h, 1 week and two weeks after the oral administration of B12-58Co. For five other patients a double tracer technique was used for intestinal correction after the simultaneous oral administration of 37 KBq of B12-58Co and 1,85 MBq of 51 Cr Cl3. The B12-58Co absorption was evaluated after intestinal correction based on subtraction of the 51Cr Cl3 contribution after the formula: B12-58Co(%ID) = WBC B12-58Co - WBC 51 Cr Cl3/1 - WBC 51 Cr Cl3. Results: the correlation with the Schilling test was found excellent: r=0,94 (n=11). The normality for WBC retention (n=7) was define as 53,2 +-12,4% ID (SD). For nine patients studied at the 7th day, the presence of a double peak (hepatic and intestinal peaks) allowed the subtraction by exponential extrapolation; the correction range was 4,4% to 37,2%. With the exception of one observation there was no difference in the measure of vitamin

  10. Study of lag time of river chenab between marala barrage and khanki headworks using radioactive tracer technique

    International Nuclear Information System (INIS)

    Ahmed, A.; Tariq, J.A.; Ahmad, N.; Iqbal, N.

    2001-05-01

    During the flood season, sometimes discharge peaks in two tributaries of the Indus River System coincide at the point of confluence and their cumulative effect threatens the downstream barrage/headworks. Reasonably accurate lag time (transit time) between different control points in relation to discharge helps mange flood routing more safely. As a part of S tudy of Lag Time of the Indus River Suystem , radioactive tracer experiment was conducted to determine the lag time between Marala Barrage and Khanki Headworks at the river Chenab. Discharge data shows that the maximum flood peak appears in August. In the monsoon period of the year 1999 the floods were low. So the radiotracer experiment was carried out at low discharge of about 538 m/sup 3/ sec/sup-1/ (19000 cusecs). An activity of about 2 Ci of /sup 82/Br radioactive tracer was injected instantaneously in the river at Marala on 1st September 1999 at 0640 hours. Monitoring of radioactivity by scintillation detectors (sodium iodide) was done at Khanki Headworks. The peak value of activity was found on September 2, 1999 at 0005 hours. The lag time was determined as 17 hours and 25 minutes. At this discharge level the river water travelled with the average speed of 3.69 km/hr. (author)

  11. [Precarious matters. The radium economy, episteme of risk and the emergence of tracer technique in national socialism].

    Science.gov (United States)

    von Schwerin, Alexander

    2009-01-01

    Following the traces of radioactive material is--as scholars have recently shown--a valuable historical approach in order to evaluate the material 'factor' of science in action. Even though the origins of materials like radium and artificial isotopes are quite different, their circulation is interconnected. A material pathway can be drawn from the radium industry to the scientific rise of artificial isotopes as indicator substances in the 1930s, continuing to the building of networks by German scientists working for the war efforts. Also, this pathway reveals the role of radiation protection in establishing that material culture. Finally, the dynamics of material traces and institutional linkages is shown by the tracer work of biophysicists and radiation biologists working at the Genetic Department of the Kaiser Wilhelm Institute for Brain Research in Berlin and at the Institut de Chimie Nucléaire at Paris, which at that time was occupied by German troops.

  12. Use of radioactive tracers in studying the transport of solids in watercourses; Emploi de traceurs radioactifs pour l'etude du transport solide dans les cours d'eau; Ispol'zovanie radioaktivnykh indikatorov dlya izucheniya peremeshcheniya tverdykh chastits v vodnykh potokakh; Empleo de indicadores radiactivos para el estudio del transporte de solidos en las corrientes de agua

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Centre d' Etudes Nucleaires de Saclay (France); Jaeery, P; Heuzel, M [Laboratoire National d' Hydraulique de Chatou (France)

    1962-01-15

    The National Hydraulics Laboratory which, in collaboration with the Saclay Nuclear Research Centre, has for several years been devising equipment and techniques for the study of sediment movements by the radioactive tracer method, is now endeavouring to develop a really quantitative method of research. Two river experiments were recently made, the first a study of shingle drifting in the Rhone, the second a study of sand movement in the Niger. The latter experiment was matched by identical experiments carried out on a scale model of the River Niger which the Chatou Laboratory has at its disposal. The experiments used Mn{sup 56} and Na{sup 24} radiation obtained by direct activation of crushed apricot stone, this representing in the scale model the natural sediment of the Niger bed. The Chatou Laboratory and the Saclay Nuclear Study Centre are at present both devoting attention to the application of radioactive tracers in studies with scale models, with the twin aims of: (a) Obtaining a single research tool for use under natural conditions and with scale models in order to gauge the trustworthiness of the model, in the calibration testing stage; (b) Taking advantage of the facilities for direct observation and measurement offered by scale models in order to study prospects of improving the tracer method, with a view particularly to securing quantitative data. (author) [French] Le Laboratoire national d'hydraulique, qui depuis quelques annees a developpe, en collaboration avec le Centre d'etudes nucleaires de Saclay, les appareillages et les techniques d'etudes des mouvements de sediments par la methode des traceurs radioactifs, s'efforce actuellement de mettre au point un moyen d'investigation veritablement quantitatif. Deux experiences ont ete effectuees recemment en riviere, la premiere a ete consacree a l'etude du charriage des galets dans le Rhone, l'autre a l'etude des transports de sables dans le Niger. Cette derniere experience a ete doublee d

  13. Tracer-tracer relations as a tool for research on polar ozone loss

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Rolf

    2010-07-01

    The report includes the following chapters: (1) Introduction: ozone in the atmosphere, anthropogenic influence on the ozone layer, polar stratospheric ozone loss; (2) Tracer-tracer relations in the stratosphere: tracer-tracer relations as a tool in atmospheric research; impact of cosmic-ray-induced heterogeneous chemistry on polar ozone; (3) quantifying polar ozone loss from ozone-tracer relations: principles of tracer-tracer correlation techniques; reference ozone-tracer relations in the early polar vortex; impact of mixing on ozone-tracer relations in the polar vortex; impact of mesospheric intrusions on ozone-tracer relations in the stratospheric polar vortex calculation of chemical ozone loss in the arctic in March 2003 based on ILAS-II measurements; (4) epilogue.

  14. A comparative evaluation of drilling techniques for deposits containing free gold using radioactive gold particles as tracers

    International Nuclear Information System (INIS)

    Clarkson, R.

    1998-01-01

    In the summers of 1992 and 1994, the author designed and carried out a statistically valid research program using radioactivated gold particles as tracers (radiotracers). Two types of fully cased normal circulation (N / C) drills, two types of reverse circulation (R/C) drills and three solid auger drills were evaluated under a variety of field conditions. A frozen cylindrical core of compacted gravels containing four sizes ( 1.2, 0.60, 0.30 and 0.15 mm), (+l4,+28,+48and+100 mesh)of radiotracers was placed in 44 drill holes and the holes were re drilled. Scintillometers were used to track free gold losses due to spillage and blow-by around the collar (top) of the hole. Some gold particles were located in temporary traps in the drilling equipment and these particles would have contaminated subsequent samples (as carry-over). Several myths commonly attributed to particular drilling methods were dispelled. There was no significant difference between the recovery of the four sizes of gold particles with any of the drills tested. Observations and down-hole scintillometer records indicated that the free gold particles did not follow the bit down the hole and were either carried out of the hole or forced onto the sides of the hole at or above the depth at which the radioactive gold was positioned. A comparative evaluation of the results of these tests is presented

  15. Characterization and application of a radioimmunoassay for reduced, carboxymethylated human luteinizing hormone. cap alpha. -subunit. [/sup 125/I tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Keutmann, H.T.; Beitins, I.Z.; Johnson, L.; McArthur, J.W.

    1978-12-01

    We have established a double antibody RIA using a rabbit antiserum prepared against reduced, carboxymethylated (RCXM) human LH ..cap alpha..-subunit, with RCXM-..cap alpha.. as tracer and standard. This antiserum did not cross-react with any native gonadotropins or subunit, and reacted only weakly with RCXM-..cap alpha... A tryptic digest of RCXM ..cap alpha..-subunit was completely reactive, while chymotryptic digestion abolished all immunoreactivity. By testing with separate tryptic fragments, the recognition site could be localized to a segment close to the amino-terminus of the peptide chain. When applied to measurement of serum and urine, an immunoreactive species, parallel to RCXM ..cap alpha..-subunit by serial dilution, was found in concentrations of 1-2 ng/ml in serum and 3-4 ng/ml in urine. Similar levels of the immunoreactive component were found in conditions of elevated gonadotropins (e.g. pregnancy) as well as gonadotropin deficiency (panhypopituitarism and Kallmann's syndrome). After stimulation with LHRH, no rise was noted at times up to 6 h despite the fact that both LH and LH-..cap alpha.. were elevated. The data indicate that the sequence-specific antiserum may be detecting an immunoreactive form of ..cap alpha..-subunit of LH whose kinetics of appearance and disappearance differs from those of the native subunit.

  16. Fate of free amino acids in paddy and upland soils by using 13C and 15N tracer techniques

    International Nuclear Information System (INIS)

    Yamamuro, Shigekazu; Ueno, Hideto; Takahashi, Shigeru

    1999-01-01

    Direct and indirect (=through decomposition) uptakes of free amino acids (FAA) by rice and tomato plants were investigated by using 13 C- and 15 N-labeled aspartic and glutamic acids, serine, leusine and ammonium as tracers. 1) One week after the surface application of amino acid-N or NH 4 -N to paddy soil, the amounts of ammonium remaining in the soil, assimilated ammonium, denitrificated ammonium and amounts taken up by plants were similar. 2) From 5.5 to 7.7% of the FAA applied was absorbed directly by rice plants, and from 42.5 to 47.2% of that was indirectly absorbed as ammonium after decomposition. It is suggested that the FAA degraded to ammonium around 2 or 3 d and the 1- 13 C absorption rates of the FAA (RCH(NH 2 ) 13 COOH) were high in proportion to the number of carbon atoms of the R side-chain. 3) The absorption rate of N derived from the FAA by tomato plants was lower than that by rice plants, namely, from 0.4 to 1.9% in direct-uptake and from 16.0 to 29.8% in indirect-uptake. Percentage of direct-uptake of the FAA in upland soil was much lower than that in the paddy field. (author)

  17. Studies on biosorption of Cr(VI) on a green resin: dry cow dung powder and tracer technique

    International Nuclear Information System (INIS)

    Barot, N.S.; Bagla, H.K.

    2012-01-01

    The present investigation entails the application of dry cow dung powder (DCP) as an indigenous, inexpensive and eco-friendly material for the removal of Cr(VI) from aqueous medium. Batch biosorption experiments were conducted employing 51 Cr(VI) as a tracer and the effect of various process parameters such as optimum pH, temperature, amount of resin, time of equilibration, agitation speed, concentration of metal ions and interfering effect of different salts etc. were studied. The kinetic studies were carried out employing various models but the best fitting was given by Lagergren Pseudo-second order model with high correlation coefficient R 2 value of 0.997 and adsorption capacity of 10.20 mg/g. The thermodynamic parameters for biosorption were evaluated as ΔG = -2.837 kJ/mol, ΔH = -4.757 kJ/mol and ΔS = 16.64 J/mol K, which indicated spontaneous and exothermic process with high affinity of DCP for Cr(VI). Many naturally available materials are used for the biosorption of heavy metal pollutants, where most of them are physically or chemically modified. In this research work, DCP has been utilized without any pre or post chemical treatment. Thus it manifests the principle of green chemistry and proves to be an eco-friendly resin. (orig.)

  18. Studies on biosorption of Cr(VI) on a green resin: dry cow dung powder and tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Barot, N.S.; Bagla, H.K. [Kishinchand Chellaram College, Mumbai (India). Nuclear and Radiochemistry Dept.

    2012-07-01

    The present investigation entails the application of dry cow dung powder (DCP) as an indigenous, inexpensive and eco-friendly material for the removal of Cr(VI) from aqueous medium. Batch biosorption experiments were conducted employing {sup 51}Cr(VI) as a tracer and the effect of various process parameters such as optimum pH, temperature, amount of resin, time of equilibration, agitation speed, concentration of metal ions and interfering effect of different salts etc. were studied. The kinetic studies were carried out employing various models but the best fitting was given by Lagergren Pseudo-second order model with high correlation coefficient R{sup 2} value of 0.997 and adsorption capacity of 10.20 mg/g. The thermodynamic parameters for biosorption were evaluated as {Delta}G = -2.837 kJ/mol, {Delta}H = -4.757 kJ/mol and {Delta}S = 16.64 J/mol K, which indicated spontaneous and exothermic process with high affinity of DCP for Cr(VI). Many naturally available materials are used for the biosorption of heavy metal pollutants, where most of them are physically or chemically modified. In this research work, DCP has been utilized without any pre or post chemical treatment. Thus it manifests the principle of green chemistry and proves to be an eco-friendly resin. (orig.)

  19. Case study: evaluation of continuos blending silos in the cement industry, by the aid of tracer techniques

    International Nuclear Information System (INIS)

    Sebastian, C.; Maghella, G.; Mamani, E.

    2000-12-01

    Besides the actual burning process in cement manufacture, particular importance is attached to raw material preparation and homogenization, not only because of the quality of the kiln fed and therefore of the produced cement, but also because of the economy of the kiln operation, which significantly depends on the uniformity of the chemical composition of the material. As a result, the blending process of the cement raw material, before burning, is a basic stage of cement technology production. In this case, the pneumatic homogenization process is studied in a silo with a great storing and processing capacity. The objective is to evaluate the parameters which influence in the continuos operation. The method allows us to determine the optimal blending parameters, through the observation of the movement and distribution of the different fractions of fine dust raw meal, labelled with La-140 as tracer. Changes in blending according to time are discussed as well as the influence of the silo design on the degree of homogenization. It was showed that the silo blending operation has a strong influence on the production of good-quality cement as well as the implications on energy saving

  20. The mechanisms of root exudates of maize in improvement of iron nutrition of peanut in peanut/maize intercropping system by 14C tracer technique

    International Nuclear Information System (INIS)

    Zuo Yuanmei; Chen Qing; Zhang Fusuo

    2004-01-01

    The related mechanisms of root exudates of maize in improvement iron nutrition of peanut intercropped with maize was investigated by 14 C tracer technique. Neighboring roots between maize and peanut were separated by a 30 μm nylon net, the iron nutrition of peanut was also improved just like normal intercropping of maize and peanut. The results proved that root exudates of maize played an important role in improvement iron nutrition of peanut. The photosynthesis carbohydrate of maize could exuded into the rhizosphere of peanut and transfer into shoot and root of peanut in intercropping system. Root exudates of maize could increased efficiency of iron in soil and improved iron utilization of peanut

  1. 15N tracer technique for studying efficiency of deep placed fertilizer through nutriseed holder in direct seeded rice

    International Nuclear Information System (INIS)

    Asha, V.S.; Arulmozhiselvan, K.

    2006-01-01

    In order to estimate N use efficiency in deep placement of NPK straight fertilizers, two pot experiments were conducted in high clay soil with direct seeded rice. 15 N urea was used as a tracer. A newly designed 'Nutriseed Holder' was used for simultaneous deep placement of fertilizers and sowing of seeds. Each holder had two cavities, one on top for holding seed and another one at bottom for holding fertilizer material. By implanting a holder in puddled soil, a rice hill was established. The length (5 or 10 cm) and width (8 or 12 mm) of nutriseed holder was standardized while evaluating the effect of Azolla, neem and seed inoculants. Appreciably, deep placement of plain NPK fertilizer in 12 mm holder placed at 5 cm depth recorded the highest grain yield with a yield increase of 81.8 per cent during rabi 2002 (cv CO 43) and 84.8 per cent during summer 2003 (cv CO 47) over broadcast application. Further, it increased recovery of added JSN in grain + straw to the tune of 57.1 per cent in rabi and 54.7 per cent in summer as compared to broadcast application (26.1% in rabi, 34.2 in summer). Deep placement enhanced more retention in soil (up to 9.0% in rabi, 14.6% in summer) whereas broadcast application enhanced more retention in Azolla biomass that was grown in floodwater (up to 2.3 % in rabi, 4.3 % in summer). Use of 12 mm width nutriseed holder aiding deep placement at 5 cm depth was found suitable for deriving high yield and N use efficiency. (author)

  2. Investigation on the root distributions of Sivas 111/33 and Gerek A-79 wheat varieties grown under Central Anatolian conditions, using tracer techniques

    International Nuclear Information System (INIS)

    Ozbek, N.; Halitligil, M.B.; Ozdemir, E.

    1988-01-01

    In order to determine the vertical root distributions of Sivas 111/33 and Gerek-79 wheat varieties in the soil profile, two field experiments were conducted at Haymana in 1986, and at Lodumlu in 1987 using tracer techniques and 32 p as a tracer. Randomized complete blocks design as four replications was used. The plot size was 12 m 2 (240 m by 5.00 m) in which 32 p isotope plots were established with dimensions of 0.07 mxl. 25 m=0.875 m 2 . They included 4 rows of wheat and in the middle of these rows, 15 holes (25 cam apart) were opened with a portable drill. The holes either had depths of 30, 60 or 90 cm depending on the treatment selected. 4 ml carrier-free 32 p solutions were injected into the holes with the help of plastic tubes at two times, one after seedling emergence and the other at early spring. Plant samples for radioactivity measurements were taken at four different growth stages, namely tillering, shooting, heading and full maturity. The results obtained from these investigations clearly showed that: 1. The root growth of plants showed differences depending on growth stage and variety. 2. At tillering stage the roots of both wheat varieties were not able to reach to the 90 cm soil depth, however, Sivas 111/33 had relatively shallow rotting system and Gerek-79 had deep rooting system at this stage. 3. At shooting, heading and full maturity stages Sivas 111/33 had more roots than Gerek-79, while at 30 and especially 60 cm soil depths Gerek-79 had more roots. Nearly 26%, 32% and 42% of the total roots of Sivas 111/33, and 15%, 42% and 43% of the total roots of Gerek-79 were found at 90, 60 and 30 cm soil depths, respectively. 4. When compared with Gerek-79, Sivas 111/33 was found to be more suitable for drought conditions

  3. Proceedings of the atmospheric tracers and tracer application workshop

    International Nuclear Information System (INIS)

    Barr, S.; Gedayloo, T.

    1979-12-01

    In addition to presentations by participating members a general discussion was held in order to summarize and outline the goals and objectives of the workshop. A number of new low level background tracers such as heavy methanes, perfluorocarbons, multiply labeled isotopes such as 13 C 18 O 2 , helium 3, in addition to sample collection techniques and analytical methods for various tracers were discussed. This report is a summary of discussions and papers presented at this workshop

  4. Tracer research in process engineering

    International Nuclear Information System (INIS)

    Iller, E.

    1992-01-01

    The book is a review of modern applications of tracer techniques in chemical and process engineering studies. The next topics have been extensively presented: 1) media flow through apparatus; 2) the tracers in the study of media flow dynamics through apparatus; 3) mathematical interpretation of experimental data from impulse-response method; 4) the models of media flow through chemical reactors and apparatus; 5) radiotracers in mass transport study; 6) examples of practical applications of tracer methods in industrial objects. 84 refs, 96 figs, 31 tabs

  5. Tracer dispersion - experiment and CFD

    International Nuclear Information System (INIS)

    Zitny, R.

    2004-01-01

    Description of tracer distribution by means of dispersion models is a method successfully used in process engineering for fifty years. Application of dispersion models in reactor engineering for characterization of flows in column apparatus, heat exchangers, etc. is summarized and experimental tracer techniques as well as CFD methods for dispersion coefficients evaluation are discussed. Possible extensions of thermal axial dispersion model (ADM) and a core-wall ADM model suitable for description of tracer dispersion in laminar flows are suggested as well as CFD implementation as 1D finite elements. (author)

  6. A validation of the application of D2O stable isotope tracer techniques for monitoring day-to-day changes in muscle protein subfraction synthesis in humans

    Science.gov (United States)

    Wilkinson, Daniel J.; Franchi, Martino V.; Brook, Matthew S.; Narici, Marco V.; Williams, John P.; Mitchell, William K.; Szewczyk, Nathaniel J.; Greenhaff, Paul L.; Atherton, Philip J.

    2013-01-01

    Quantification of muscle protein synthesis (MPS) remains a cornerstone for understanding the control of muscle mass. Traditional [13C]amino acid tracer methodologies necessitate sustained bed rest and intravenous cannulation(s), restricting studies to ∼12 h, and thus cannot holistically inform on diurnal MPS. This limits insight into the regulation of habitual muscle metabolism in health, aging, and disease while querying the utility of tracer techniques to predict the long-term efficacy of anabolic/anticatabolic interventions. We tested the efficacy of the D2O tracer for quantifying MPS over a period not feasible with 13C tracers and too short to quantify changes in mass. Eight men (22 ± 3.5 yr) undertook one-legged resistance exercise over an 8-day period (4 × 8–10 repetitions, 80% 1RM every 2nd day, to yield “nonexercised” vs. “exercise” leg comparisons), with vastus lateralis biopsies taken bilaterally at 0, 2, 4, and 8 days. After day 0 biopsies, participants consumed a D2O bolus (150 ml, 70 atom%); saliva was collected daily. Fractional synthetic rates (FSRs) of myofibrillar (MyoPS), sarcoplasmic (SPS), and collagen (CPS) protein fractions were measured by GC-pyrolysis-IRMS and TC/EA-IRMS. Body water initially enriched at 0.16–0.24 APE decayed at ∼0.009%/day. In the nonexercised leg, MyoPS was 1.45 ± 0.10, 1.47 ± 0.06, and 1.35 ± 0.07%/day at 0–2, 0–4, and 0–8 days, respectively (∼0.05–0.06%/h). MyoPS was greater in the exercised leg (0–2 days: 1.97 ± 0.13%/day; 0–4 days: 1.96 ± 0.15%/day, P < 0.01; 0–8 days: 1.79 ± 0.12%/day, P < 0.05). CPS was slower than MyoPS but followed a similar pattern, with the exercised leg tending to yield greater FSRs (0–2 days: 1.14 ± 0.13 vs. 1.45 ± 0.15%/day; 0–4 days: 1.13 ± 0.07%/day vs. 1.47 ± 0.18%/day; 0–8 days: 1.03 ± 0.09%/day vs. 1.40 ± 0.11%/day). SPS remained unchanged. Therefore, D2O has unrivaled utility to quantify day-to-day MPS in humans and inform on short

  7. Evaluating the role of re-adsorption of dissolved Hg(2+) during cinnabar dissolution using isotope tracer technique.

    Science.gov (United States)

    Jiang, Ping; Li, Yanbin; Liu, Guangliang; Yang, Guidi; Lagos, Leonel; Yin, Yongguang; Gu, Baohua; Jiang, Guibin; Cai, Yong

    2016-11-05

    Cinnabar dissolution is an important factor controlling mercury (Hg) cycling. Recent studies have suggested the co-occurrence of re-adsorption of the released Hg during the course of cinnabar dissolution. However, there is a lack of feasible techniques that can quantitatively assess the amount of Hg re-adsorbed on cinnabar when investigating cinnabar dissolution. In this study, a new method, based on isotope tracing and dilution techniques, was developed to study the role of Hg re-adsorption in cinnabar dissolution. The developed method includes two key components: (1) accurate measurement of both released and spiked Hg in aqueous phase and (2) estimation of re-adsorbed Hg on cinnabar surface via the reduction in spiked (202)Hg(2+). By adopting the developed method, it was found that the released Hg for trials purged with oxygen could reach several hundred μgL(-1), while no significant cinnabar dissolution was detected under anaerobic condition. Cinnabar dissolution rate when considering Hg re-adsorption was approximately 2 times the value calculated solely with the Hg detected in the aqueous phase. These results suggest that ignoring the Hg re-adsorption process can significantly underestimate the importance of cinnabar dissolution, highlighting the necessity of applying the developed method in future cinnabar dissolution studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Radiochemical tracers in marine biology

    International Nuclear Information System (INIS)

    Petrocelli, S.R.; Anderson, J.W.; Neff, J.M.

    1977-01-01

    Tracers have been used in a great variety of experimentation. More recently, labeled materials have been applied in marine biological research. Some of the existing tracer techniques have been utilized directly, while others have been modified to suit the specific needs of marine biologists. This chapter describes some of the uses of tracers in marine biological research. It also mentions the problems encountered as well as offering possible solutions and discusses further applications of these techniques. Only pertinent references are cited and additional information may be obtained by consulting these references. Due to their relative ease of maintenance, freshwater species are also utilized in studies which involve radiotracer techniques. Since most of these techniques e directly applicable to marine species, some of these studies will also be included

  9. Measurement of IgG-blocking antibodies: development and application of a radioimmunoassay. [/sup 125/I tracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Sobotka, A.K.; Valentine, M.D.; Ishizaka, K.; Lichtenstein, L.M.

    1976-07-01

    A radioimmunoassay for measuring blocking antibodies has been developed. We used the ragweed antigen E system to show that the same blocking antibodies (IgG) measured by inhibition of antigen-induced leukocyte histamine release were precipitated in the binding assay (r/sub s/ = 0.96 p less than 0.001), thus validating a widely applicable technique for measuring blocking antibodies. Binding of phospholipase-A (Phos-A), the major allergen in honey bee venom, was also shown to correlate significantly with inhibition of histamine release. Hymenoptera (insect) hypersensitivity was used as a model to demonstrate application of the binding assay. Sera obtained from patients undergoing whole body extract therapy contained negligible amounts of specific blocking antibodies. Significantly higher blocking antibody titers to both whole honey bee venom and Phos-A were measured in sera drawn from patients immunized with whole venom. The use of the binding radioimmunoassay should facilitate management of allergic disease processes in which blocking antibodies are thought to be protective.

  10. NON DESTRUCTIVE APPLICATION OF RADIOACTIVE TRACER TECHNIQUE FOR CHARACTERIZATION OF INDUSTRIAL GRADE ANION EXCHANGE RESINS INDION GS-300 AND INDION-860

    Directory of Open Access Journals (Sweden)

    P.U. SINGARE

    2014-02-01

    Full Text Available The paper deals with the application of radio isotopic non-destructive technique in the characterization of two industrial grade anion exchange resins Indion GS-300 and Indion-860. For the characterization of the two resins, 131I and 82Br were used as tracer isotopes to trace the kinetics of iodide and bromide ion-isotopic exchange reactions. It was observed that the values of specific reaction rate (min−1, amount of iodide ion exchanged (mmol, initial rate of iodide ion exchange (mmol/min and log Kd were calculated as 0.328, 0.577, 0.189 and 19.7 respectively for Indion GS-300 resin, which was higher than the respective values of 0.180, 0.386, 0.070 and 17.0 calculated for Indion-860 resins when measured under identical experimental conditions. Also at a constant temperature of 40.0 °C, as the concentration of labeled iodide ion solution increases 0.001 M to 0.004 M, the percentage of iodide ions exchanged increases from 75.16 % to 78.36 % for Indion GS-300 resins, which was higher than the increases from 49.65 % to 52.36 % compared to that obtained for Indion-860 resins. The overall results indicate that under identical experimental conditions, Indion GS-300 resins show superior performance over Indion-860 resins.

  11. Non Destructive Application of Radioactive Tracer Technique for Characterization of Industrial Grade Anion Exchange Resins Indio GS-300 and Indion-860

    International Nuclear Information System (INIS)

    Singare, P. U.

    2014-01-01

    The paper deals with the application of radio isotopic non-destructive technique in the characterization of two industrial grade anion exchange resins Indion GS-300 and Indion-860. For the characterization of the two resins, 131 I and 82 Br were used as tracer isotopes to trace the kinetics of iodide and bromide ion-isotopic exchange reactions. It was observed that the values of specific reaction rate (min -1 ), amount of iodide ion exchanged (mmol), initial rate of iodide ion exchange (mmol/min) and log K d were calculated as 0.328, 0.577, 0.189 and 19.7 respectively for Indion GS-300 resin, which was higher than the respective values of 0.180, 0.386, 0.070 and 17.0 calculated for Indion-860 resins when measured under identical experimental conditions. Also at a constant temperature of 40.0 .deg. C, as the concentration of labeled iodide ion solution increases 0.001 M to 0.004 M, the percentage of iodide ions exchanged increases from 75.16 % to 78.36 % for Indion GS-300 resins, which was higher than the increases from 49.65 % to 52.36 % compared to that obtained for Indion-860 resins. The overall results indicate that under identical experimental conditions, Indion GS-300 resins show superior performance over Indion-860 resins

  12. Fertilizer-N uptake by Chickpea and Wheat Crops under Intercropping System using 15N Tracer Technique

    International Nuclear Information System (INIS)

    Farid, I.M.; Moursy, A.A.A.; Kotb, E.A.; Ismail, M.

    2012-01-01

    A field experiment was carried out at the Plant Nutrition and Fertilization Unit, Soils and Water Research Department, Nuclear Research Center, Atomic Energy Authority, Inshas, Egypt on wheat and chickpea inter cropping. The Objective of this current work is to study Organic matter decomposition under clean agriculture system in sandy soil using nuclear technique. The lowest portion of nitrogen derived from fertilizer was resulted from application of compost and chickpea straw treatments. It is worthy to mention that full recommend dos of fertilizer (20 kg N fed-1) was efficiently used by shoots of chickpea plants. Portion of nitrogen derived from fertilizer by seeds of chickpea was lower than those recorded with shoots. Generally, there was no big significant difference between nitrogen gained by shoots and seeds from the organic materials. This holds true with all treatments. More declines in nitrogen derived from soil percentages were resulted from application of cow manure and compost treatments under different rate of mineral fertilizer, the application 100% MF treatment induced higher nitrogen derived from soil pool as compared to the other treatments. The best value of nitrogen derived from air was detected followed by compost, while the lowest value was recorded with wheat straw. In general, nitrogen derived from air by shoots lower than those up taken by seeds of chickpea plant. Application of wheat straw and compost treatments were enhanced the nitrogen derived from fertilizer by straw of wheat plant as compared to caw manure, maize stalk, chickpea straw, but Ndff% in grains of wheat , cow manure and maize stalk increased as compared to the other treatment. Application of organic materials, chickpea straw and cow manure achieved the highest value of Ndfo% by straw of wheat plant as compared to maize stalk, compost and wheat straw. But values of nitrogen derived from organic in grains of wheat plants, the application of chickpea straw and wheat straw

  13. Understanding the hydrochemical evolution of a coastal dune system in SW England using a multiple tracer technique

    International Nuclear Information System (INIS)

    Allen, Debbie; Darling, W. George; Williams, Peter J.; Stratford, Charlie J.; Robins, Nick S.

    2014-01-01

    Highlights: • Braunton Burrows is an alkaline rain-fed system with no saline intrusion. • Marine aerosols and shell dissolution dominate unsaturated zone water quality. • Hydrochemical evolution in the unsaturated zone is rapid. • Slower evolutionary processes contribute to water quality in the saturated zone. • High dune groundwaters were 13–16 yr old and dune slack groundwater 5–7 yr old. - Abstract: An improved knowledge of the hydrology of coastal dune systems is desirable for successful management of their diverse ecology under a changing climate. As a near-pristine coastal dune spit system, Braunton Burrows (SW England) is an ideal location for the study of the natural processes governing recharge to the dune groundwater system and the evolution of its water quality. Whereas previous investigations have tended to focus on inter-dune slacks, this study has also given attention to infiltration through the high dunes. Cores were taken through dunes and the resulting sand samples processed to provide information on grain size distribution and porewater chemistry. Groundwater samples were obtained from beneath dunes and slacks. A variety of geochemical techniques were applied including hydrochemistry, stable isotopes and residence time indicators. The unsaturated zone profiles indicate the existence of piston flow recharge with an infiltration rate of 0.75–1 m/yr, although faster rates probably also occur locally. Groundwater beneath the high dunes gave ages in the range 13–16 yr, compared to the dune slack groundwater ages of 5–7 yr, and an age of 22 yr for groundwater from the underlying mudstone aquifer. The chemistry of waters in both unsaturated and saturated zones is dominated by Ca and HCO 3 , supplemented by variable amounts of other ions derived from marine aerosols and limited reaction with sand grains and their coatings. The main chemical evolution of the porewaters occurs rapidly through the mobilisation of surface salt crusts and

  14. Tracer techniques in electroplating. IV

    International Nuclear Information System (INIS)

    Stverak, B.; Rousar, I.

    1979-01-01

    In copper extraction from a solution containing trace amounts of silver the extraction of silver is controlled by diffusion. Mass transfer coefficients may be determined from the surface density of the extracted silver. The values are used in designing a system with suitable mixing for even mass distribution on the entire surface of the electrode. Silver was labelled with the sup(110m)Ag isotope with a specific activity of 0.74 GBq/g Ag. The surface density values were determined autoradiographically. The mass transfer coefficients were calculated from autoradiogram optical densities and the surface density of the silver to be determined. It was found that mixing by nitrogen through a cullet was considerably nonhomogeneous; when the gas was distributed along the bottom the mixing was more homogeneous. (H.S.)

  15. Contribution of nuclear microanalysis and of 18O tracer technique to study the oxygen sublattice in high Tc superconducting thin films

    International Nuclear Information System (INIS)

    Siejka, J.

    1994-01-01

    At first a short review of IBA contribution to the determination of composition and structure, including phonon properties of high T c superconducting oxides is presented. In the second part, IBA contribution to the elucidation of the mechanisms of thin film growth is presented. The emphasis is on the complementarity of IBA, Raman spectroscopy and XRD techniques to characterize thin films of high T c superconducting oxides. In the third part, some recent results related mainly to YBaCuO films grown on (100) oriented single crystalline bulk materials (MgO, LaAlO 3 , SrTiO 3 ) is discussed. In these experiments, IBA, XRD and Raman spectroscopies were used to study the oxygen content in a series of YBaCuO films prepared in different conditions of pressure and temperature. In the case of c-axis oriented films a good agreement between these three methods was found for the films cooled down at high oxygen pressure and a significant disagreement for the films cooled down at low oxygen pressure, showing structures with anomalous c-axis parameter. In the case of a-axis oriented films grown on SrTiO 3 substrates it was found that the low T c values (∼ 70-80 K) are not correlated with the oxygen content but rather with a disorder in the oxygen sublattice. The disorder in the oxygen sublattice was studied using the 16 O(α, α) 16 O resonance in random and channeling geometry. These results are correlated with the data provided by Raman spectroscopy. The 18 O tracer technique was used to estimate the diffusion coefficient in the a-axis oriented YBaCuO films showing a huge anisotropy of the 18 O labelling. Combining Raman and IBA techniques, the selective 18 O labelling of the CuO chain-planes was evidenced. The defects in the 18 O enriched CuO chain-planes were studied using the 18 O(p, α) 15 N nuclear resonant reaction in random and channeling geometries. Some preliminary results related to roughness of YBaCuO films are also discussed. The physical implications of these

  16. Simulation and interpretation of inter-well tracer tests

    Directory of Open Access Journals (Sweden)

    Dugstad Øyvind

    2013-05-01

    Full Text Available In inter-well tracer tests (IWTT, chemical compounds or radioactive isotopes are used to label injection water and gas to establish well connections and fluid patterns in petroleum reservoirs. Tracer simulation is an invaluable tool to ease the interpretation of IWTT results and is also required for assisted history matching application of tracer data. In this paper we present a new simulation technique to analyse and interpret tracer results. Laboratory results are used to establish and test formulations of the tracer conservation equations, and the technique is used to provide simulated tracer responses that are compared with observed tracer data from an extensive tracer program. The implemented tracer simulation methodology use a fast post-processing of previously simulated reservoir simulation runs. This provides a fast, flexible and powerful method for analysing gas tracer behaviour in reservoirs. We show that simulation time for tracers can be reduced by factor 100 compared to solving the tracer flow equations simultaneously with the reservoir fluid flow equations. The post-processing technique, combined with a flexible built-in local tracer-grid refinement is exploited to reduce numerical smearing, particularly severe for narrow tracer pulses.

  17. Tracer a application in marine outfall studies

    International Nuclear Information System (INIS)

    Genders, S.

    1979-01-01

    The applicability of radioactive and fluorescent tracers for field studies to predict or investigate waste water transport and dispersion from marine outfalls is evaluated. The application of either instantaneous or continuous tracer release, 'in situ' detection of tracers and data processing are considered. The necessity of a combined use of tracer techniques and conventional hydrographic methods for a statistical prediction of transport and dillution of waste water are pointed out. A procedure to determine an outlet distance from the coast, which satisfy bathing water criteria is outlined. (M.A.) [pt

  18. Integrating isotopic tracer techniques with Bayesian modelling for improved assessment and management of sedimentation problems in the Gilgel-Gibe catchment, Ethiopia

    Science.gov (United States)

    Dume, Bayu; Amsalu, Nebiyu; Bode, Samuel; Mtei, Kelvin; Munishi, Linus; Navas, Ana; Semmens, Brice; Smith, Hugh; Stock, Brian; Blake, Will; Boeckx, Pascal

    2017-04-01

    receptor cobble bed river after the 2016 rainy season. In order to extract reliable information on the sources of fine sediment delivered into rivers and dam, new isotopic techniques (e.g., Compound Specific Stable Isotopes (CSSIs)) combined with other isotopic techniques (fallout radionuclides) and geochemical tracer properties (via WD-XRF) were employed to quantify sediment sources. Results from this demonstration catchment are discussed in the context of the wider sediment pressures on the Hydro-Electric Power infrastructure of the Gilgel Gibe system.

  19. Secondary vestibulocerebellar projections to the flocculus and uvulo-nodular lobule of the rabbit: a study using HRP and double fluorescent tracer techniques

    NARCIS (Netherlands)

    A.H. Epema; N.M. Gerrits (N.); J. Voogd (Jan)

    1990-01-01

    textabstractThe distribution of vestibular neurons projecting to the flocculus and the nodulus and uvula of the caudal vermis (Larsell's lobules X and IX) was investigated with retrograde axonal transport of horseradish peroxidase and the fluorescent tracers Fast Blue, Nuclear Yellow and Diamidino

  20. Radioactive tracers in the sea

    International Nuclear Information System (INIS)

    Jenkins, W.J.; Livingston, H.D.

    1980-01-01

    Artificial radionuclides introduced to the oceans during the last four decades have proved invaluable tools for study of many processes in marine water columns and sediments. Both global and close-in fallout of radioactivity from atmospheric nuclear weapons testing have distributed these radionuclides widely, and in amounts sufficient to be useful as tracers. An additional source of considerable significance and tracer potential comes from coastal discharges of European nuclear fuel reprocessing wastes. The nature of these sources, types and amounts of radionuclides introduced and the time histories of their introduction generate a variety of tracer distributions which illuminate a broad spectrum of physical and chemical processes active over a wide range of timescales. Depending on their respective chemistries, artificial radionuclides have been demonstrated to exhibit both conservative and non-conservative properties in the oceans. Some examples are given of the uses made of soluble, conservative tracers for the study of oceanic transport processes and of non-conservative tracers for studies of processes which move them to, and mix them within, marine sediments. Sampling and measurement techniques which have been used in these studies are described

  1. Industrial tracer application in people's republic of china

    International Nuclear Information System (INIS)

    Sun Maoyi

    1987-01-01

    A number of important applications of radioisotopes and their compounds used as tracers in petroleum industry, metallurgical industry, mechanical industry, chemical industry, electronic industry, hydrology and water conservancy in China are introduced in this paper. And the tracer technique applied to entomology is also mentioned. The industrial tracer applications are successful and beneficial in People's Republic of China from the examples given. (author)

  2. APLICACIONES CLÍNICAS DE LAS TÉCNICAS NUCLEARES EN EL ESTUDIO DEL SINCRONISMO VENTRICULAR / Clinical applications of nuclear techniques in the study of ventricular synchronism

    Directory of Open Access Journals (Sweden)

    Amalia Peix González

    2012-07-01

    Full Text Available ResumenTécnicas incruentas como la ecocardiografía, la resonancia magnética nuclear y los estudios de Medicina Nuclear (ventriculografía radioisotópica y gammagrafía de perfusión miocárdica con tomografía de emisión de fotón único, proporcionan información indirecta sobre el sincronismo ventricular cuando se utilizan parámetros de contractilidad mecánica. El análisis de fase de Fourier es un instrumento útil para el empleo de técnicas nucleares con este propósito y se ha aplicado, tanto en la ventriculografía radioisotópica como en la gammagrafía de perfusión. En este trabajo se presenta una revisión en el tiempo de los fundamentos y aplicaciones clínicas de las técnicas nucleares en el estudio del sincronismo ventricular. En la actualidad es la gammagrafía SPECT-gatillada, dentro de las técnicas nucleares, la más utilizada, por la posibilidad que ofrece de evaluar perfusión, función y sincronismo intraventricular en el mismo examen. / AbstractNoninvasive techniques such as echocardiography, nuclear magnetic resonance imaging and nuclear medicine studies (radionuclide ventriculography and myocardial perfusion scintigraphy with single photon emission tomography, provide indirect information about ventricular synchronism when parameters of mechanical contractility are used. The Fourier phase analysis is a useful tool for the use of nuclear techniques for this purpose, and has been applied in both radionuclide ventriculography and perfusion scintigraphy. A review in time of the basics and clinical applications of nuclear techniques in the study of ventricular synchronism is presented in this article. Nowadays, the gated-SPECT scintigraphy is the most common among nuclear techniques because it allows assessing perfusion, function, and intraventricular synchronism in the same test.

  3. Tracer and hydrometric techniques to determine the contribution of glacier melt to a proglacial stream in the Ötztal Alps (Tyrol, Austria)

    Science.gov (United States)

    Schmieder, Jan; Marke, Thomas; Strasser, Ulrich

    2016-04-01

    Glaciers are important seasonal water contributors in many mountainous landscapes. For water resources management it is important to know about the timing and amount of released glacier melt water, especially in downstream regions where the water is needed (hydropower, drinking water) or where it represents a potential risk (drought, flood). Seasonal availability of melt water is strongly dependent on boundary layer atmospheric processes and becomes even more relevant in a changing climate. Environmental tracers are a useful tool in the assessment of snow and ice water resources, because they provide information about the sources, flow paths and traveling times of water contributing to streamflow at the catchment scale. Previously, high-elevation tracer studies throughout the Alps have been scarce as they require intense field work in remote areas. However, hydrometric and meteorological measurements combined with tracer analyses help to unravel streamflow composition and improve the understanding of hydroclimatological processes. On top of that, empirical studies are necessary to parameterize and validate hydrological models in more process-oriented ways, rather than comparing total measured and simulated runoff only. In the present study three approaches are applied to derive glacier melt contributions to a proglacial stream at the seasonal scale and to identify their individual advances and limitations. Tracers used for each approach are (1) electrical conductivity, (2) stable isotopes of water and (3) heavy metals. The field work was conducted during the summer of 2015 in the glaciated (35%) high-elevation catchment of the Hochjochbach, a small sub-basin (17 km²) of the Ötztaler Ache river in the Austrian Alps, ranging from 2400 to 3500 m.a.s.l. in elevation. Hydroclimatological data was provided by an automatic weather station and a gauging station equipped with a pressure transducer. Water samples from shallow groundwater, streamflow, glacier and snow melt

  4. Study with a steam tracer in a zone near well Az-64, in the Los Azufres geothermal field, Mich.; Estudio con un trazador de vapor en la zona aledana al pozo Az-64, en el campo geotermico de Los Azufres, Mich.

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, Eduardo R. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: iglesias@iie.org.mx; Flores Armenta, Magaly; Quijano Leon, Jose Luis; Torres Rodriguez, Marco A. [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico); Torres, Rodolfo J.; Reyes Picasso, Neftali [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Sandoval Medina, Fernando [Comision Federal de Electricidad, Gerencia de Proyectos Geotermoelectricos, Morelia, Michoacan (Mexico)

    2009-01-15

    and 539 m from the injector. The results showed the six monitored wells are recharged from injection in Az-64 and quantified the corresponding recoveries as steam. Because only a steam-phase tracer was used, we were unable to determine liquid-recovery amounts. The work also allowed us to characterize relations between the permeability in the studied zone and the known distribution of faults. Some relationships were suggested unconsidered before. [Spanish] En el estudio con trazadores precedente a este, efectuado en la zona Maritaro-La Cumbre del campo geotermico de Los Azufres, Mich., se comprobo que la inyeccion en el pozo Az-15 recarga a un grupo de pozos situados a una distancia maxima del inyector de algo menos de 2000 m. Y se comprobo que la inyeccion en dicho pozo o bien no recarga a pozos situados a mas de 2300 m hacia el este, en las inmediaciones de la falla Laguna Verde, o lo hace muy lentamente en un largo periodo. Como es importante recargar la zona mencionada en ultimo termino, se decidio entonces explorar la posibilidad de recargarla desde el pozo Az-64, localizado en dicha area. Para ello se diseno el presente estudio. Se designaron seis pozos productores para monitorear el arribo del trazador. Debido a que todos estos pozos producen vapor (aunque varios producen tambien liquido), y por consideraciones economicas, se decidio utilizar en este caso un trazador de vapor solamente. Se utilizo hexafluoruro de azufre (SF6), un trazador utilizado con exito previamente en este campo. El 24 de octubre de 2006 se inyectaron 96.4 kg de SF6 en el pozo Az-64. El monitoreo de los pozos se realizo durante 156 dias a partir de esa fecha. El trazador se detecto en los seis pozos productores monitoreados. En todos los casos las formas de las curvas de residencia manifestaron claramente la naturaleza fracturada de la permeabilidad involucrada. En todos los casos las curvas de recuperacion del trazador indicaron claramente que la llegada del mismo se habia completado

  5. Study of liquid and steam tracers at the Maritaro - La Cumbre area of the Los Azufres geothermal field, Mich.; Estudio con trazadores de liquido y vapor en la zona Maritaro - La Cumbre del campo geotermico de Los Azufres, Mich.

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, Eduardo R [Instituto de Investigaciones Electricas, Cuernavaca, Morelos, (Mexico)]. E-mail: iglesias@iie.org.mx; Flores Armenta, Magaly; Quijano Leon, Jose Luis; Torres Rodriguez, Marco A [Comision Federal de Electricidad, Morelia, Michoacan (Mexico); Torres, Rodolfo J; Reyes Picasso, Neftali [Instituto de Investigaciones Electricas, Cuernavaca, Morelos, (Mexico)

    2008-01-15

    We ran two simultaneous tracer tests in the Maritaro-La Cumbre area of the Los Azufres geothermal field in Mexico. We wished to determine whether or not fluids injected in well Az-15 recharged the productive areas of six production wells and to estimate the fractions of injected fluid recovered in them, if any. Because only three of the wells produce water and all of them produce steam, two tracers were used, sulfur hexafluoride (SF{sub 6}) for the gas phase and 1,3,6 naphthalene trisulfonate (1,3,6-nts) for the liquid phase. All of the observation wells recorded SF{sub 6}, and the three water-producing wells recorded 1,3,6-nts, proving that fluids injected in well Az-15 do recharge the area of interest. When sampling was suspended, the three water-producing wells were still producing 1,3,6-nts at significant rates. The total recovery of 1,3,6-nts at wells Az-65D, Az-04 and Az-28, 279 days after injection when sampling was halted, were, respectively, 6.1%, 0.90% y 0.16%, for a total of 7.61%. We concluded that these quantities constitute the lower boundaries for the respective recovery factors. When sampling was halted, wells Az-65D, Az-66D and Az-30 were still producing some SF{sub 6} at lower rates, and the rest of the wells were no longer recording the gas phase tracer. The total recovery of SF{sub 6} at wells Az-65D, Az-04, Az-41, Az-30, Az-28 and Az-66D were, respectively, 4.82 e-02%, 1.37 e-03%, 1.48 e-03%, 6.38 e-04%, 1.38 e-03% y 4.31 e-04%, for a total of 5.35 e-02%. The liquid recharge occurred in orders of magnitude greater than the steam. [Spanish] Se efectuaron dos pruebas simultaneas en la zona Maritaro-La Cumbre del campo geotermico de Los Azufres, Mich., Mexico. Los objetivos de estas pruebas fueron determinar si la salmuera de desecho inyectada en el pozo Az-15 recarga las zonas de alimentacion de seis pozos productores designados por CFE, y estimar que fraccion de lo inyectado recarga dichos pozos productores. Debido a que solo tres de los pozos

  6. Applying tracer techniques to NPP liquid effluents for estimating the maximum concentration of soluble pollutants in a man-made canal

    International Nuclear Information System (INIS)

    Varlam, Carmen; Stefanescu, Ioan; Varlam, Mihai; Raceanu, Mircea; Enache, Adrian; Faurescu, Ionut; Patrascu, Vasile; Bucur, Cristina

    2006-01-01

    Full text: The possibility of a contamination agent being accidentally or intentionally spilled upstream from a water supply is a constant concern to those diverting and using water from a channel. A method of rapidly estimating the travel-time or dispersion is needed for pollution control or warning system on channels where data are scarce. Travel-time and mixing of water within a stream are basic streamflow characteristics needed in order to predict the rate of movement and dilution of pollutants that could be introduced in the stream. In this study we propose using tritiated liquid effluents from CANDU type nuclear power plant as a tracer, to study hydrodynamics on Danube-Black Sea Canal. This canal is ideal for this kind of study, because wastewater evacuations occur occasionally due to technical operations of nuclear power plant. Tritiated water can be used to simulate the transport and dispersion of solutes in Danube-Black Sea Canal because they have the same physical characteristics as the water. Measured tracer-response curves produced from injection of a known amount of soluble tracer provide an efficient method of obtaining the necessary data. This method can estimate: (1) the rate of movement of a solute through the canal reach: (2) the rate of peak attenuation concentration of a conservative solute in time; and (3) the length of time required for the solute plume to pass a point in the canal. This paper presents the mixing length calculation for particular conditions (lateral branch of the canal, and lateral injection of wastewater from the nuclear power plant). A study of published experimentally-obtained formulas was used to determine proper mixing length. Simultaneous measurements in different locations of the canal confirm the beginning of the experiment. Another result used in a further experiment concerns the tritium level along the Danube-Black Sea Canal. We measured tritium activity concentration in water sampled along the Canal between July

  7. Packet Tracer network simulator

    CERN Document Server

    Jesin, A

    2014-01-01

    A practical, fast-paced guide that gives you all the information you need to successfully create networks and simulate them using Packet Tracer.Packet Tracer Network Simulator is aimed at students, instructors, and network administrators who wish to use this simulator to learn how to perform networking instead of investing in expensive, specialized hardware. This book assumes that you have a good amount of Cisco networking knowledge, and it will focus more on Packet Tracer rather than networking.

  8. Radioisotope tracers in industrial flow studies

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    The scope of radioisotope tracer work carried out by ANSTO has involved most sectors of Australian industry including iron and steel coal, chemical, petrochemical, natural gas, metallurgical, mineral, power generation, liquified air plant, as well as port authorities, water and sewerage instrumentalities, and environmental agencies. A major class of such studies concerns itself with flow and wear studies involving industrial equipment. Some examples are discussed which illustrate the utility of radioisotope tracer techniques in these applications

  9. A novel double-tracer technique to characterize absorption, distribution, metabolism and excretion (ADME) of [14C]tofogliflozin after oral administration and concomitant intravenous microdose administration of [13C]tofogliflozin in humans.

    Science.gov (United States)

    Schwab, Dietmar; Portron, Agnes; Backholer, Zoe; Lausecker, Berthold; Kawashima, Kosuke

    2013-06-01

    Human mass balance studies and the assessment of absolute oral bioavailability (F) are usually assessed in separate studies. Intravenous microdose administration of an isotope tracer concomitant to an unlabeled oral dose is an emerging technique to assess F. We report a novel double-tracer approach implemented for tofogliflozin combining oral administration of a radiolabel tracer with concomitant intravenous administration of a stable isotope tracer. Tofogliflozin is a potent and selective sodium/glucose cotransporter 2 inhibitor for the treatment of type 2 diabetes mellitus currently in clinical development. The objectives of the present study were to assess the systemic exposure of major circulating metabolites, excretion balance, F and contribution of renal clearance (CLR) to total clearance (CL) of tofogliflozin in healthy subjects within one study applying a novel double-tracer technique. Six healthy male subjects received 20 mg [(12)C/(14)C]tofogliflozin (3.73 MBq) orally and a concomitant microdose of 0.1 mg [(13)C]tofogliflozin intravenously. Pharmacokinetics of tofogliflozin were determined for the oral and intravenous route; the pharmacokinetics of the metabolites M1 and M5 were determined for the oral route. Quantification of [(12)C]tofogliflozin in plasma and urine and [(13)C]tofogliflozin in plasma was performed by selective LC-MS/MS methods. For the pre-selected metabolites of tofogliflozin, M1 and M5, a validated liquid chromatography-tandem mass spectrometry (LC-MS/MS) was applied to plasma and urine samples. Total radioactivity was assessed in plasma, urine and feces. Pharmacokinetic analysis was conducted by non-compartmental methods. The pharmacokinetics of tofogliflozin in healthy subjects were characterized by an F of 97.5 ± 12.3 %, CL of 10.0 ± 1.3 l/h and volume of distribution at steady-state (V(ss)) of 50.6 ± 6.7 l. The main route of elimination of total drug-related material was by excretion into urine (77.0 ± 4.1 % of the dose). The

  10. Using Tracer Technology to Characterize Contaminated Pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Maresca, Joseph, W., Jr., Ph.D.; Bratton, Wesley, L., Ph.D., P.E.; Dickerson, Wilhelmina; Hales, Rochelle

    2005-12-30

    The Pipeline Characterization Using Tracers (PCUT) technique uses conservative and partitioning, reactive or other interactive tracers to remotely determine the amount of contaminant within a run of piping or ductwork. The PCUT system was motivated by a method that has been successfully used to characterize subsurface soil contaminants and is similar in operation to that of a gas chromatography column. By injecting a ?slug? of both conservative and partitioning tracers at one end (or section) of the piping and measuring the time history of the concentration of the tracers at the other end (or another section) of the pipe, the presence, location, and amount of contaminant within the pipe or duct can be determined. The tracers are transported along the pipe or duct by a gas flow field, typically air or nitrogen, which has a velocity that is slow enough so that the partitioning tracer has time to interact with the contaminant before the tracer slug completely passes over the contaminate region. PCUT not only identifies the presence of contamination, it also can locate the contamination along the pipeline and quantify the amount of residual. PCUT can be used in support of deactivation and decommissioning (D&D) of piping and ducts that may have been contaminated with hazardous chemicals such as chlorinated solvents, petroleum products, radioactive materials, or heavy metals, such as mercury.

  11. Improving Marine Ecosystem Models with Biochemical Tracers

    Science.gov (United States)

    Pethybridge, Heidi R.; Choy, C. Anela; Polovina, Jeffrey J.; Fulton, Elizabeth A.

    2018-01-01

    Empirical data on food web dynamics and predator-prey interactions underpin ecosystem models, which are increasingly used to support strategic management of marine resources. These data have traditionally derived from stomach content analysis, but new and complementary forms of ecological data are increasingly available from biochemical tracer techniques. Extensive opportunities exist to improve the empirical robustness of ecosystem models through the incorporation of biochemical tracer data and derived indices, an area that is rapidly expanding because of advances in analytical developments and sophisticated statistical techniques. Here, we explore the trophic information required by ecosystem model frameworks (species, individual, and size based) and match them to the most commonly used biochemical tracers (bulk tissue and compound-specific stable isotopes, fatty acids, and trace elements). Key quantitative parameters derived from biochemical tracers include estimates of diet composition, niche width, and trophic position. Biochemical tracers also provide powerful insight into the spatial and temporal variability of food web structure and the characterization of dominant basal and microbial food web groups. A major challenge in incorporating biochemical tracer data into ecosystem models is scale and data type mismatches, which can be overcome with greater knowledge exchange and numerical approaches that transform, integrate, and visualize data.

  12. Tracer attenuation in groundwater

    Science.gov (United States)

    Cvetkovic, Vladimir

    2011-12-01

    The self-purifying capacity of aquifers strongly depends on the attenuation of waterborne contaminants, i.e., irreversible loss of contaminant mass on a given scale as a result of coupled transport and transformation processes. A general formulation of tracer attenuation in groundwater is presented. Basic sensitivities of attenuation to macrodispersion and retention are illustrated for a few typical retention mechanisms. Tracer recovery is suggested as an experimental proxy for attenuation. Unique experimental data of tracer recovery in crystalline rock compare favorably with the theoretical model that is based on diffusion-controlled retention. Non-Fickian hydrodynamic transport has potentially a large impact on field-scale attenuation of dissolved contaminants.

  13. Isotopic marking and tracers

    International Nuclear Information System (INIS)

    Morel, F.

    1997-01-01

    The use of radioactive isotopes as tracers in biology has been developed thanks to the economic generation of the required isotopes in accelerators and nuclear reactors, and to the multiple applications of tracers in the life domain; the most usual isotopes employed in biology are carbon, hydrogen, phosphorus and sulfur isotopes, because these elements are present in most of organic molecules. Most of the life science knowledge appears to be dependent to the extensive use of nuclear tools and radioactive tracers; the example of the utilization of radioactive phosphorus marked ATP to study the multiple reactions with proteins, nucleic acids, etc., is given

  14. The Possibility of Making a Quantitative Study of the Precipitin Reaction by Gamma-Radioactive Tracers; Possibilite d'une Etude Quantitative de la Reaction de Precipitation par Marquage a l'Aide d'Emetteurs Gamma; Vozmozhnost' kolichestvennogo opredeleniya reaktsii osazhdeniya s pomoshch'yu gamma-radioaktivnykh indikatorov; Estudio Cuantitativo de la Reaccion de Precipitacion con Ayuda de Indicadores Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Bonev, L.; Todorov, S.; Robev, S. [Nauchno-Issledovatel' skij Institut Radiologii i Radiacionnoj Bezopasnosti, Sofija (Bulgaria)

    1965-10-15

    The paper presents the first results of the quantitative determination of the precipitin reaction (formation of an antigen-antibody complex) by labelling the precipitating components with gamma-radioactive tracers which do not chemically interact with albuminous molecules. As tracers it is possible to use chrome-manganese and nickel-copper compounds, whose tendency to hydrolyze permits the fixation of the radioactive tracer on the antigen and antibody respectively. The radioactivity of the components is determined by a multichannel pulse-height analyser. The results obtained show that the precipitation curve, plotted on the basis of radiometric data, closely corresponds to the curve plotted by the well-known quantitative methods used to determine albumin. The paper discusses the possibilities of using the method described. (author) [French] Les auteurs communiquent les premiers resultats d'une etude quantitative qu'ils ont faite de la reaction de precipitation (formation du complexe antigene-anticorps) en marquant les composants du precipites avec des emetteurs gamma qui ne reagissent pas chimiquement avec les molecules d'albumine. Pour le marquage, on peut utiliser des composes de chrome/manganese ou de fer qui subissent facilement l'hydrolyse et assurent de ce fait la fixation de la substance radioactive sur l'antigene et, partant, sur l'anticorps. La radioactivite des composants est determinee a l'aide d'un selecteur d'amplitudes a plusieurs canaux. Les resultats montrent que la courbe de precipitation obtenue avec les donnees radiometriques concorde parfaitement avec celle que l'on obtient par les methodes quantitatives connues servant au dosage de l'albumine. Les auteurs discutent les possibilites d'application de la methode etudiee. (author) [Spanish] Los autores presentan los primeros resultados de un estudio cuantitativo de la reaccion de precipitacion (formacion del complejo antigeno-anticuerpo) que efectuaron marcando los componentes de precipitacion con

  15. A double-tracer technique to characterize absorption, distribution, metabolism and excretion (ADME) of [14C]-basimglurant and absolute bioavailability after oral administration and concomitant intravenous microdose administration of [13C6]-labeled basimglurant in humans.

    Science.gov (United States)

    Guerini, Elena; Schadt, Simone; Greig, Gerard; Haas, Ruth; Husser, Christophe; Zell, Manfred; Funk, Christoph; Hartung, Thomas; Gloge, Andreas; Mallalieu, Navita L

    2017-02-01

    1. The emerging technique of employing intravenous microdose administration of an isotope tracer concomitantly with an [ 14 C]-labeled oral dose was used to characterize the disposition and absolute bioavailability of a novel metabotropic glutamate 5 (mGlu5) receptor antagonist under clinical development for major depressive disorder (MDD). 2. Six healthy volunteers received a single 1 mg [ 12 C/ 14 C]-basimglurant (2.22 MBq) oral dose and a concomitant i.v. tracer dose of 100 μg of [ 13 C 6 ]-basimglurant. Concentrations of [ 12 C]-basimglurant and the stable isotope [ 13 C 6 ]-basimglurant were determined in plasma by a specific LC/MS-MS method. Total [ 14 C] radioactivity was determined in whole blood, plasma, urine and feces by liquid scintillation counting. Metabolic profiling was conducted in plasma, urine, blood cell pellet and feces samples. 3. The mean absolute bioavailability after oral administration (F) of basimglurant was ∼67% (range 45.7-77.7%). The major route of [ 14 C]-radioactivity excretion, primarily in form of metabolites, was in urine (mean recovery 73.4%), with the remainder excreted in feces (mean recovery 26.5%). The median t max for [ 12 C]-basimglurant after the oral administration was 0.71 h (range 0.58-1.00) and the mean terminal half-life was 77.2 ± 38.5 h. Terminal half-life for the [ 14 C]-basimglurant was 178 h indicating presence of metabolites with a longer terminal half-life. Five metabolites were identified with M1-Glucuronide as major and the others in trace amounts. There was minimal binding of drug to RBCs. IV pharmacokinetics was characterized with a mean ± SD CL of 11.8 ± 7.4 mL/h and a Vss of 677 ± 229 L. 4. The double-tracer technique used in this study allowed to simultaneously characterize the absolute bioavailability and disposition characteristics of the new oral molecular entity in a single study.

  16. Tracers Detect Aquifer Contamination

    National Research Council Canada - National Science Library

    Enfield, Carl

    1995-01-01

    The EPA's National Laboratory (NRMRL) at Ada, OK, along with the University of Florida and the University of Texas, have developed a tracer procedure to detect the amount of contamination in aquifer formations...

  17. Radio-isotopic tracers

    International Nuclear Information System (INIS)

    Wolfangel, R.G.

    1976-01-01

    The invention concerns the dispersions that may be used for preparing radio-isotopic tracers, technetium labelled dispersions, processes for preparing these dispersions and their use as tracers. Technetium 99m sulphur colloids are utilized as scintillation tracers to give a picture of the reticulo-endothelial system, particularly the liver and spleen. A dispersion is provided which only requires the addition of a radioactive nuclide to form a radioactively labelled dispersion that can be injected as a tracer. It is formed of a colloid of tin sulphur dispersed in an aqueous buffer solution. Such a reagent has the advantage of being safe and reliable and is easier to use. The colloid can be prepared more quickly since additions of several different reagents are avoided. There is no need to heat up and no sulphuretted hydrogen, which is a toxic gas, is used [fr

  18. Chemotherapeutic agent and tracer composition and use thereof

    International Nuclear Information System (INIS)

    Babb, A. L.

    1985-01-01

    A therapeutic composition suitable for extracorporeal treatment of whole blood comprises a dialyzable chemotherapeutic agent and a dialyzable fluorescable tracer means. The removal rate of the fluorescable tracer compound from treated blood during hemodialysis is a function of the removal rate of unreacted chemotherapeutic agent present. The residual chemotherapeutic agent concentration after hemodialysis is ascertained by measuring the concentration of the fluorescable tracer compound in a dialysate using fluorometric techniques

  19. Tracers and tracing methods

    International Nuclear Information System (INIS)

    Leclerc, J.P.

    2001-01-01

    The first international congress on 'Tracers and tracing methods' took place in Nancy in May 2001. The objective of this second congress was to present the current status and trends on tracing methods and their applications. It has given the opportunity to people from different fields to exchange scientific information and knowledge about tracer methodologies and applications. The target participants were the researchers, engineers and technologists of various industrial and research sectors: chemical engineering, environment, food engineering, bio-engineering, geology, hydrology, civil engineering, iron and steel production... Two sessions have been planned to cover both fundamental and industrial aspects: 1)fundamental development (tomography, tracer camera visualization and particles tracking; validation of computational fluid dynamics simulations by tracer experiments and numerical residence time distribution; new tracers and detectors or improvement and development of existing tracing methods; data treatments and modeling; reactive tracer experiments and interpretation) 2)industrial applications (geology, hydrogeology and oil field applications; civil engineering, mineral engineering and metallurgy applications; chemical engineering; environment; food engineering and bio-engineering). The program included 5 plenary lectures, 23 oral communications and around 50 posters. Only 9 presentations are interested for the INIS database

  20. Experiments to Evaluate and Implement Passive Tracer Gas Methods to Measure Ventilation Rates in Homes

    Energy Technology Data Exchange (ETDEWEB)

    Lunden, Melissa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Heredia, Elizabeth [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Logue, Jennifer [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-01

    This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison between different gas sampling methods, and the effect of different ventilation conditions.

  1. Bottom sediment transport by radioactive tracer techniques off a stretch of the southern coast from Sao Paulo State - Brazil; Trasnporte do sedimento de fundo por tecnicas de tracadores radioativos ao largo de trecho da costa sul do Estado de Sao Paulo - Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Bomtempo, V.L. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN), Belo Horizonte, MG (Brazil)

    1995-12-31

    This paper presents the methodology and results obtained with radioactive tracer techniques as applied to study sea-bottom sediments movements off a stretch of the southern coast of Sao Paulo State, Brazil, namely Praia do Una. Three injections of ground glass containing Iridium-192 were made and the behaviour of this material was tracked by special detection techniques, as it was acted upon by hydrodynamic agents, in two distinct periods of the year of 1982 (summer and winter). Measurement of hydrodynamic parameters was conducted simultaneously with tracer experiments. From the experiments with radioactive tracers, combined with other conventional studies, qualitative and quantitative conclusions could be drawn, as follows: waves are the prevailing agents in moving bottom sediments; during summer time, onshore and alongshore transport can be identified; during winter time, offshore and alongshore transport are present; for summer conditions, Massif transport rate was estimated to be 150 kg m{sup -1} day {sup -1}. (author). 2 refs, 3 figs.

  2. Estudio EPIFARM

    Directory of Open Access Journals (Sweden)

    Martín Morales A

    2010-12-01

    Full Text Available INTRODUCCIÓN Los farmacéuticos comunitarios pueden ser un importante primer punto de contacto con los pacientes con disfunción eréctil (DE, pero hasta la fecha no hay ningún estudio sobre las características de los hombres que acuden a un farmacéutico solicitando consejo o tratamiento para la DE. OBJETIVO Caracterizar los perfiles de los hombres que solicitan tratamiento para la DE en la farmacia, con o sin receta de inhibidores de la fosfodiesterasa tipo 5 (iPDE5. MÉTODOS Entre septiembre y noviembre de 2008 se realizó un estudio observacional, transversal y multicéntrico en farmacias comunitarias de España. De aquellos hombres que solicitaban consejo o tratamiento para la DE, cada investigador reclutó un paciente que tenía receta médica de iPDE5 y otro que acudía sin receta médica. Los farmacéuticos del estudio completaron un cuestionario de datos demográficos, clínicos y conductuales del paciente, incluido el Cuestionario de salud sexual para varones (Sexual Health Inventory for Men. VARIABLES PRINCIPALES Características demográficas y respuestas a los cuestionarios. RESULTADOS 574 farmacéuticos seleccionaron a 1.147 pacientes, de los cuales 1.113 fueron incluidos en el análisis. No se observaron diferencias estadísticas entre los grupos en cuanto al peso, la hipertensión, la diabetes mellitus, la hipercolesterolemia, la dislipidemia, la depresión o el estrés. Tampoco se observaron diferencias estadísticas respecto a la gravedad de la DE (p = 0,7892 ni a la proporción de hombres sin DE en cada grupo (p = 0,5755. En ambos grupos, los pacientes habían presentado síntomas de DE durante una media de veintiséis meses antes de la primera consulta a un profesional sanitario. Para el 60,2% de los pacientes incluidos en el grupo sin receta, la visita a la farmacia fue la primera ocasión en la que habían hablado de su DE con un profesional sanitario, y el 50% de aquellos que habían hablado previamente de la DE lo hab

  3. Exploring Hydrofluorocarbons as Groundwater Age Tracers (Invited)

    Science.gov (United States)

    Haase, K. B.; Busenberg, E.; Plummer, L. N.; Casile, G.; Sanford, W. E.

    2013-12-01

    Groundwater dating tracers are an essential tool for analyzing hydrologic conditions in groundwater systems. Commonly used tracers for dating post-1940's groundwater include sulfur hexafluoride (SF6), chlorofluorocarbons (CFCs), 3H-3He, and other isotopic tracers (85Kr, δ2H and δ18O isotopes, etc.). Each tracer carries a corresponding set of advantages and limitations imposed by field, analytical, and interpretive methods. Increasing the number available tracers is appealing, particularly if they possess inert chemical properties and unique temporal emission histories from other tracers. Atmospherically derived halogenated trace gases continue to hold untapped potential for new tracers, as they are generally inert and their emission histories are well documented. SF5CF3, and CFC-13 were previously shown to have application as dating tracers, though their low mixing ratios and low solubility require large amounts of water to be degassed for their quantification. Two related groups of compounds, hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) are hypothesized to be potential age tracers, having similar mixing ratios to the CFCs and relatively high solubility. However, these compounds yield gas chromatography electron capture detector (GC-ECD) responses that are 10-2 -10-5 less than CFC-12, making purge and trap or field stripping GC-ECD approaches impractical. Therefore, in order to use dissolved HCFCs and HFCs as age tracers, different approaches are needed. To solve this problem, we developed an analytical method that uses an atomic emission detector (GC-AED) in place of an ECD to detect fluorinated compounds. In contrast to the ECD, the AED is a universally sensitive, highly linear, elementally specific detector. The new GC-AED system is being used to measure chlorodifluoromethane (HCFC-22), 1,1,1,2-tetrafluoroethane (HFC-134a), and other fluorinated compounds in one liter water samples to study their potential as age dating tracers. HCFC-22 is a

  4. Use of caesium-137 as a tracer of erosion and sedimentation: Handbook for the application of the caesium-137 technique. UK Overseas Development Administration research scheme R4579

    Energy Technology Data Exchange (ETDEWEB)

    Walling, D E; Quine, T A

    1993-10-01

    The caesium 137 technique has become an important tool for investigating soil erosion. It permits retrospective assessment of medium-term erosion rates. The application of the technique requires only one field visit, and the results can be provided within a relatively short time. The soil redistribution rates estimated represent an average for the last 30-35 years, and are therefore less influenced by extreme events. The rates estimated represent the sum of all erosive processes. Both rates and patterns of soil redistribution may be quantitatively assessed. A range of erosion estimates may be obtained, including mean rates of erosion and deposition and net rates of soil export from the field. The whole field may be studied without disturbance to the slope environment. The spatial resolution of the data obtained is defined by the sampling strategy. Chapters of part 1 discuss the basis of the {sup 137}Cs technique, the potential for its further development, and define a protocol for its application. Part 2 includes descriptions of case studies from China, Zimbabwe and Lesotho, which illustrate the value of the {sup 137}Cs technique in the assessment of soil erosion.

  5. Use of caesium-137 as a tracer of erosion and sedimentation: Handbook for the application of the caesium-137 technique. UK Overseas Development Administration research scheme R4579

    International Nuclear Information System (INIS)

    Walling, D.E.; Quine, T.A.

    1993-10-01

    The caesium 137 technique has become an important tool for investigating soil erosion. It permits retrospective assessment of medium-term erosion rates. The application of the technique requires only one field visit, and the results can be provided within a relatively short time. The soil redistribution rates estimated represent an average for the last 30-35 years, and are therefore less influenced by extreme events. The rates estimated represent the sum of all erosive processes. Both rates and patterns of soil redistribution may be quantitatively assessed. A range of erosion estimates may be obtained, including mean rates of erosion and deposition and net rates of soil export from the field. The whole field may be studied without disturbance to the slope environment. The spatial resolution of the data obtained is defined by the sampling strategy. Chapters of part 1 discuss the basis of the 137 Cs technique, the potential for its further development, and define a protocol for its application. Part 2 includes descriptions of case studies from China, Zimbabwe and Lesotho, which illustrate the value of the 137 Cs technique in the assessment of soil erosion

  6. Wairakei tracer tests 1983

    International Nuclear Information System (INIS)

    McCabe, W.J.; Barry, B.J.

    1984-05-01

    Tracer tests, with and without, hot water reinjection into WK213 showed returns of tracer iodine-131; in wells in both the Waiora Valley and the eastern end of the field. The effect of reinjection at a rate of 200 cu. m/h was to reduce the arrived time from 15 to 7 days. Increasing the rate of reinjection into WK62 from 30 cu. m/h to 200 cu. m/h seemed to increase the initial velocity of the tracer wave and the distance it moved. However, returns were recorded only in the adjacent wells WK61 and WK63 with a very small, and three days delayed, response in WK43

  7. Models for tracer flow

    International Nuclear Information System (INIS)

    Zuber, A.

    1983-01-01

    A review and discussion is given of mathematical models used for interpretation of tracer experiments in hydrology. For dispersion model, different initial and boundary conditions are related to different injection and detection modes. Examples of applications of various models are described and commented. (author)

  8. Enhanced Oil Recovery: Aqueous Flow Tracer Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Rovani; John Schabron

    2009-02-01

    A low detection limit analytical method was developed to measure a suite of benzoic acid and fluorinated benzoic acid compounds intended for use as tracers for enhanced oil recovery operations. Although the new high performance liquid chromatography separation successfully measured the tracers in an aqueous matrix at low part per billion levels, the low detection limits could not be achieved in oil field water due to interference problems with the hydrocarbon-saturated water using the system's UV detector. Commercial instrument vendors were contacted in an effort to determine if mass spectrometry could be used as an alternate detection technique. The results of their work demonstrate that low part per billion analysis of the tracer compounds in oil field water could be achieved using ultra performance liquid chromatography mass spectrometry.

  9. Biological tracer for waste site characterization

    International Nuclear Information System (INIS)

    Strong-Gunderson, J.

    1995-01-01

    Remediating hazardous waste sites requires detailed site characterization. In groundwater remediation, characterizing the flow paths and velocity is a major objective. Various tracers have been used for measuring groundwater velocity and transport of contaminants, colloidal particles, and bacteria and nutrients. The conventional techniques use dissolved solutes, dyes. and gases to estimate subsurface transport pathways. These tracers can provide information on transport and diffusion into the matrix, but their estimates for groundwater flow through fractured regions are very conservative. Also, they do not have the same transport characteristics as bacteria and suspended colloid tracers, both of which must be characterized for effective in-place remediation. Bioremediation requires understanding bacterial transport and nutrient distribution throughout the acquifer, knowledge of contaminants s mobile colloidal particles is just essential

  10. Single-tracer technique to evaluate pulmonary edema and its application to detect the effect of hexamethylene diisocyanate trimer aerosol exposures

    International Nuclear Information System (INIS)

    Valentini, J.E.; Wong, K.L.; Alarie, Y.

    1983-01-01

    Two hours after a four-hour exposure to hexamethylene diisocyanate trimer (HDIt) aerosol between 2.5 and 39 mg/m3, mice were injected iv with 51 Cr-EDTA (chromium ethylenediaminetetraacetate). Ten minutes later the lung was lavaged. A larger amount of 51 Cr-EDTA was detected in the lung lavage of HDIt mice than of controls in a concentration-related fashion. The concentration-response curve was shifted to the left compared with that constructed using lung weight increase as response. Kinetic studies of the plasma level of 51 Cr-EDTA revealed a three-exponential profile in normal mice, and similar plasma levels were obtained with mice exposed to 18-24 mg/m3 HDIt. However, both the amount of 51 Cr-EDTA in the alveolar space and concentration in the pulmonary extravascular compartment were higher in HDIt-exposed mice than in controls. The data of 51 Cr-EDTA distribution in the lung were fitted with a three-compartment model. According to the model, HDIt exposures increase the permeability constants of 51 Cr-EDTA transport into the alveolar space from blood which accounts for the larger amount of 51 Cr-EDTA in lung lavage of HDIt-exposed mice. This 51 Cr-EDTA injection and lung lavage technique is a sensitive method for detecting pulmonary edema

  11. Use of tracer techniques for studying the influence of addition elements and crystallographic parameters on intergranular diffusion in austenitic stainless steels

    International Nuclear Information System (INIS)

    Assassa, Wafaa.

    1975-01-01

    16% chromium, 14% nickel stainless steel, austenitic at all temperatures, covers a wide field of industrial use. Its behavior was studied in order to find out more about how impurities affect the three basic elements forming the solid solution. After a review of some general properties (segregation, precipitation, migration, structure and energy of boundaries) the physico-chemical aspect of the grain boundaries was investigated. The atomic diffusion rates of the three basic elements forming the solid-solution were compared in order to evaluate their mutual kinetics and the effects of impurities such as C, Si or addition elements such as Ni were studied. The radiotracer technique was used ( 59 Fe, 51 Cr, 63 Ni). The structural aspect of the grain boundaries of this type of steel was then examined by analyzing the self-diffusion of iron in preoriented bicrystals and considering the properties of the boundaries parallel with and perpendicular to the (001) bending axis. A study was devoted to the effect of a new structural parameter, asymmetry of the grain boundaries, little analyzed in diffusion [fr

  12. Characterization of sodium transport in Acholeplasma laidlawii B cells and in lipid vesicles containing purified A. laidlawii (Na+-Mg2+)-ATPase by using nuclear magnetic resonance spectroscopy and 22Na tracer techniques

    International Nuclear Information System (INIS)

    Mahajan, S.; Lewis, R.N.; George, R.; Sykes, B.D.; McElhaney, R.N.

    1988-01-01

    The active transport of sodium ions in live Acholeplasma laidlawii B cells and in lipid vesicles containing the (Na+-Mg2+)-ATPase from the plasma membrane of this microorganism was studied by 23Na nuclear magnetic resonance spectroscopic and 22 Na tracer techniques, respectively. In live A. laidlawii B cells, the transport of sodium was an active process in which metabolic energy was harnessed for the extrusion of sodium ions against a concentration gradient. The process was inhibited by low temperatures and by the formation of gel state lipid in the plasma membrane of this organism. In reconstituted proteoliposomes containing the purified (Na+-Mg2+)-ATPase, the hydrolysis of ATP was accompanied by the transport of sodium ions into the lipid vesicles, and the transport process was impaired by reagents known to inhibit ATPase activity. At the normal growth temperature (37 degrees C), this transport process required a maximum of 1 mol of ATP per mol of sodium ion transported. Together, these results provide direct experimental evidence that the (Na+-Mg2+)-ATPase of the Acholeplasma laidlawii B membrane is the cation pump which maintains the low levels of intracellular sodium characteristic of this microorganism

  13. Application of fluorescent-and radioactive tracers in Sedimentalogy

    International Nuclear Information System (INIS)

    Alencar, L.M.L. de.

    1981-01-01

    The development of techniques of sediment labelling, creating the possibility of using fluorescent and radioactive tracers not yet applied in Brazil, in the area of sedimentology, is studied. (A.R.H.) [pt

  14. Methods of 15N tracer research in biological systems

    International Nuclear Information System (INIS)

    Hirschberg, K.; Faust, H.

    1985-01-01

    The application of the stable isotope 15 N is of increasing importance in different scientific disciplines, especially in medicine, agriculture, and the biosciences. The close correlation between the growing interest and improvements of analytical procedures resulted in remarkable advances in the 15 N tracer technique. On the basis of the latest results of 15 N tracer research in life sciences and agriculture methods of 15 N tracer research in biological systems are compiled. The 15 N methodology is considered under three headings: Chemical analysis with a description of methods of sample preparation (including different separation and isolation methods for N-containing substances of biological and agricultural origin) and special procedures converting ammonia to molecular nitrogen. Isotopic analysis with a review on the most important methods of isotopic analysis of nitrogen: mass spectrometry (including the GC-MS technique), emission spectrometry, NMR spectroscopy, and other analytical procedures. 15 N-tracer techniques with a consideration of the role of the isotope dilution analysis as well as different labelling techniques and the mathematical interpretation of tracer data (modelling, N turnover experiments). In these chapters also sources of errors in chemical and isotopic analysis, the accuracy of the different methods and its importance on tracer experiments are discussed. Procedures for micro scale 15 N analysis and aspects of 15 N analysis on the level of natural abundance are considered. Furthermore some remarks on isotope effects in 15 N tracer experiments are made. (author)

  15. Tracer tests Wairakei

    International Nuclear Information System (INIS)

    McCabe, W.J.; Manning, M.R.; Barry, B.J.

    1980-07-01

    The report summarises the radioactive tracer tests, using iodine-131 and bromine-82, made in the Wairakei geothermal field over the period 1978-80. Injection of tracer into three wells with strong cool water downflows at about 300-400m below ground level, produced strong rapid responses from the only deep wells feeding from about 800-1000m and lying in the south-westerly direction from the injection wells, i.e. parallel to the fault planes. Shallower wells, even though in some cases much closer to the injection well, reacted much more slowly. Velocities, as measured by peak arrival times, as high as 22m/h over 200m and 11m/h over 650m, were found. The flow patterns for the cool water feeds to the production area are discussed

  16. Radioactive tracers in Sedimentology

    International Nuclear Information System (INIS)

    Rodrigues, H.T.

    1973-01-01

    First is given a broad description of the uses of radioactive tracers in Sedimentology. The general method is established, including determinations of probability and standard deviation. Following are determined: the response law of the detector, the minimum mass for statistical detection, and the minimum mass for dynamic detection. The granularity is an important variable in these calculations. Final conclusions are given, and results are compared with existing theories

  17. Use of radioactive tracers in dynamic sedimentology

    International Nuclear Information System (INIS)

    Tola, Francois.

    1982-01-01

    In the first part, developments in the use of radioactive tracers in sedimentology are recalled together with the corresponding fields of application and the identities of the main users. The state-of-the-art in France is also discussed; The main characteristics of the method are then described and compared with those of more classical methods. The results that can be obtained with tracer methods are then outlined. The criteria employed to establish the granulometry characteristics of the tracer, the particular radioisotope to be used, and the masses and activities involved, are treated. A list is then given of the main isotopes available in France and their characteristics. The various different labelling techniques employed are studied together with their respective advantages and disadvantages. The special case of pelitic sediments is mentioned. The use of reduced model isotope generators, double labelling and applications to studies of the mud plug in the Gironde Estuary are also discussed. The methods and materials used for injecting and detecting tracers are described, emphasis being given to the economic factors associated with the use of radioactive tracers in sedimentology. The second part of the report contains two chapters: - studies of transport by driftage: presentation and analysis of results and the application of the Count Rate Balance method to obtain quantitative information on transport; - studies of in-suspension transport of fine sediments in the sea: the procedures adopted from the moment when the tracer is introduced up to the time when the results are analyzed and interpreted, enables the trajectories and mean velocities of the transported sediments to be determined together with their degree of dilution and their settling speeds and rates; it is also possible to investigate the evolution and horizontal dispersion of the sediments in this way. Results from recent experiments are presented in both parts of the report

  18. Tracers and Tracer Testing: Design, Implementation, Tracer Selection, and Interpretation Methods

    Energy Technology Data Exchange (ETDEWEB)

    G. Michael Shook; Shannon L.; Allan Wylie

    2004-01-01

    Conducting a successful tracer test requires adhering to a set of steps. The steps include identifying appropriate and achievable test goals, identifying tracers with the appropriate properties, and implementing the test as designed. When these steps are taken correctly, a host of tracer test analysis methods are available to the practitioner. This report discusses the individual steps required for a successful tracer test and presents methods for analysis. The report is an overview of tracer technology; the Suggested Reading section offers references to the specifics of test design and interpretation.

  19. Heat tracer methods

    Science.gov (United States)

    Healy, Richard W.; Scanlon, Bridget R.

    2010-01-01

    The flow of heat in the subsurface is closely linked to the movement of water (Ingebritsen et al., 2006). As such, heat has been used as a tracer in groundwater studies for more than 100 years (Anderson, 2005). As with chemical and isotopic tracers (Chapter 7), spatial or temporal trends in surface and subsurface temperatures can be used to infer rates of water movement. Temperature can be measured accurately, economically, at high frequencies, and without the need to obtain water samples, facts that make heat an attractive tracer. Temperature measurements made over space and time can be used to infer rates of recharge from a stream or other surface water body (Lapham, 1989; Stonestrom and Constantz, 2003); measurements can also be used to estimate rates of steady drainage through depth intervals within thick unsaturated zones (Constantz et al., 2003; Shan and Bodvarsson, 2004). Several thorough reviews of heat as a tracer in hydrologic studies have recently been published (Constantz et al., 2003; Stonestrom and Constantz, 2003; Anderson, 2005; Blasch et al., 2007; Constantz et al., 2008). This chapter summarizes heat-tracer approaches that have been used to estimate recharge.Some clarification in terminology is presented here to avoid confusion in descriptions of the various approaches that follow. Diffuse recharge is that which occurs more or less uniformly across large areas in response to precipitation, infiltration, and drainage through the unsaturated zone. Estimates of diffuse recharge determined using measured temperatures in the unsaturated zone are referred to as potential recharge because it is possible that not all of the water moving through the unsaturated zone will recharge the aquifer; some may be lost to the atmosphere by evaporation or plant transpiration. Estimated fluxes across confining units in the saturated zone are referred to as interaquifer flow (Chapter 1). Focused recharge is that which occurs directly from a point or line source, such

  20. Rate equations for tracer studies in recirculating reactors

    Energy Technology Data Exchange (ETDEWEB)

    Happel, J [Columbia Univ., New York (USA). Dept. of Chemical Engineering

    1974-10-01

    The employment of isotopic tracers is a useful technique for gaining insight into the rate controlling steps of a complex chemical reaction such as is frequently encountered in heterogeneous catalysis. An effective procedure has been to superpose tracer transfer on a reaction which is occurring under steady state conditions. If tracer transfer is employed in this fashion it is often possible to assess the individual step velocities in an assumed reaction mechanism. If transient transfer of tracer is now introduced it is possible in addition to estimate surface concentrations of chemisorbed species. The purpose of the present paper is to present the mathematical relationships involved when transfer of the tracer is not differential in the investigation. For this purpose a simple example is chosen to illustrate the various possibilities involved.

  1. Rate equations for tracer studies in recirculatinng reactors

    International Nuclear Information System (INIS)

    Happel, J.

    1974-01-01

    The employment of isotopic tracers is a useful technique for gaining insight into the rate controlling steps of a complex chemical reaction such as is frequently encountered in heterogeneous catalysis. An effective procedure has been to superpose tracer transfer on a reaction which is occurring under steady state conditions. If tracer transfer is employed in this fashion it is often possible to assess the individual step velocities in an assumed reaction mechanism. If transient transfer of tracer is now introduced it is possible in addition to estimate surface concentrations of chemisorbed species. The purpose of the present paper is to present the mathematical relationships involved when transfer of the tracer is not differential in the investigation. For this purpose a simple example is chosen to illustrate the various possibilities involved. (auth.)

  2. Deep water sheet transfer using tracer techniques

    International Nuclear Information System (INIS)

    Archimbaud-Potherat, Michelle

    1970-01-01

    In order to identify the water from a phreatic water sheet in the Bassin d'Aquitaine, the following components were selected for analysis: fluorides, chlorides, bromides, iodides, uranium, thorium, sodium, potassium, calcium, magnesium, cerium and boron. The methods used are described. Sixty different kinds of water from the cretaceous, eocene, oligocene and miocene eras were chemically analyzed; particular chemical properties and coefficients of correlation between the elements, characteristic of different geological periods, were observed. A geochemical interpretation of the results obtained with boron is given. (author) [fr

  3. Application of tracer technique in cement industry

    International Nuclear Information System (INIS)

    Baran'ai, L.

    1979-01-01

    Application is stated of the radioisotope indication method in the cement industry. The method was applied in three directions. In the first direction, by means of labelling of 300 steel mill balls by cobalt-60, wear of them was examined. The degree of wear of milling balls in the process of milling was determined according to the decrease of their weight. Radioactive label served only for tracing controll balls. In the second direction, according to the natural radioactivity being presented in ashes by radioisotopes radium-226 and thorium-229, amount of ashes in the products of cement milling was determined (in the mill product, cement product, flying dust and back loading groats). In the third direction, by means of labelling of definite fractions of mille by radioisotope gold-198, optimization of technological parameters of silos were raw meal is homogenization. The following technological parameters have been established: amount of homogenized material; time of homogenization and frequency of intensity changing of supplied compressed air jet [ru

  4. Tracer techniques in landslide area surveys

    Energy Technology Data Exchange (ETDEWEB)

    Turcek, P [Slovenska Vysoka Skola Technicka, Bratislava (Czechoslovakia)

    1982-10-01

    One of the most important effects leading to slope movements is the action of surface and ground water on rocks. The rock movement usually occurs as a result of dilatation. The increased rock porosity in the area of the slide zone leads to higher permeability. The measurement of the ground water flow rate by the single borehole method using the /sup 131/I radiotracer in objects with perforated casings, installed in the landslide zone, can be used to locate sliding surfaces. The method was successfully applied in landslides at Miksova, Turany, Liskova and Podhradi where drainage measures were taken, the efficiency of which can be checked periodically.

  5. Chemical Tracer Methods: Chapter 7

    Science.gov (United States)

    Healy, Richard W.

    2017-01-01

    Tracers have a wide variety of uses in hydrologic studies: providing quantitative or qualitative estimates of recharge, identifying sources of recharge, providing information on velocities and travel times of water movement, assessing the importance of preferential flow paths, providing information on hydrodynamic dispersion, and providing data for calibration of water flow and solute-transport models (Walker, 1998; Cook and Herczeg, 2000; Scanlon et al., 2002b). Tracers generally are ions, isotopes, or gases that move with water and that can be detected in the atmosphere, in surface waters, and in the subsurface. Heat also is transported by water; therefore, temperatures can be used to trace water movement. This chapter focuses on the use of chemical and isotopic tracers in the subsurface to estimate recharge. Tracer use in surface-water studies to determine groundwater discharge to streams is addressed in Chapter 4; the use of temperature as a tracer is described in Chapter 8.Following the nomenclature of Scanlon et al. (2002b), tracers are grouped into three categories: natural environmental tracers, historical tracers, and applied tracers. Natural environmental tracers are those that are transported to or created within the atmosphere under natural processes; these tracers are carried to the Earth’s surface as wet or dry atmospheric deposition. The most commonly used natural environmental tracer is chloride (Cl) (Allison and Hughes, 1978). Ocean water, through the process of evaporation, is the primary source of atmospheric Cl. Other tracers in this category include chlorine-36 (36Cl) and tritium (3H); these two isotopes are produced naturally in the Earth’s atmosphere; however, there are additional anthropogenic sources of them.

  6. Radon diagnostics and tracer gas measurements

    International Nuclear Information System (INIS)

    Jilek, K.; Brabec, M.

    2004-01-01

    An outline is presented of the tracer gas technique, which is used for continuous measurements of air ventilation rate (generally time-varying) and for simultaneous estimation of air ventilation rate and radon entry rate, and some of its limitations are discussed. The performance of this technique in the calculation of the air ventilation rate is demonstrated on real data from routine measurements. The potential for air ventilation rate estimation based on radon measurements only is discussed. A practical application is described of the tracer gas technique to a simultaneous estimation of the air ventilation rate and radon entry rate in a real house where the effectiveness of radon remedy was tested. The following main advantages of the CO tracer gas techniques are stressed: (i) The averaging method continuous determination of the ventilation rate with good accuracy (≤ 20 %). (ii) The newly presented and verified method based on simultaneous measurements of radon concentration and CO gas concentration enables separate continuous measurements of the radon entry rate and ventilation rate. The results of comparative measurements performed with the aim to estimate the inaccuracy in determination of radon entry rate showed acceptable and good agreement up to approximately 10 %. The results of comparative measurements performed with the aim to estimate the mutual commensuration of the method to the determination of the ventilation rate confirmed the expected unreliability the two parametric non-linear regression method, which is the most frequently used method in radon diagnostic in the Czech Republic

  7. Guidebook on radioisotope tracers in industry

    International Nuclear Information System (INIS)

    1990-01-01

    The idea of using tracers (chemical, dyes, etc.) in the investigation of complex physical phenomena has always attracted the attention of scientists and engineers. When radioactive isotopes became available it was immediately recognized that they offered an almost ideal solution to tracer selection. This book is devoted to reviewing the present status of the tracer method as such and to its applications to those branches of industry which have derived large benefits from the use of this modern technology. The main objectives of the IAEA's Industrial Applications and Chemistry Section is to help Member States in introducing to their own industries the different isotope and radiation techniques which have become available as a result of developments in the nuclear sciences. This section proposed the preparation of this guidebook, putting together various radiotracer methods and the experience obtained so far in their industrial use. Chapters 2 to 4 cover the general concept of tracers, technology and safety aspects, as well as data evaluation and interpretation. In chapter 5, therefore, general applications are discussed. In chapter 6, specialists in selected fields discuss their experience in radiotracer applications in various types of industrial activity. Most case studies are illustrated by at least one detailed example of an experiment carried out at an industrial installation. Current trends in the development of radiotracer methods are discussed in chapter 7, from both a theoretical and a practical viewpoint. Some possible new RTT applications in the future are also discussed here. Sealed radioactive sources are used almost as often as radioisotope tracers in industrial measurements. Annex I gives a short review of these techniques. Readers who are interested in the basic principles of radioisotope production will find the necessary information in Annex II. Annexes III, V and VI provide a demonstration of fundamental relations and properties; useful

  8. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  9. Suitability of tracers; Eignung von Tracern

    Energy Technology Data Exchange (ETDEWEB)

    Klotz, D. [GSF - Forschungszentrum fuer Umwelt und Gesundheit GmbH, Neuherberg (Germany). Inst. fuer Hydrologie

    1999-02-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other. [Deutsch] Mit Hilfe der hydrologischen Markierungstechniken koennen Aussagen ueber die Richtung und die Geschwindigkeit von Bewegungen des unterirdischen Wassers gemacht werden. Der einfachere Fall liegt vor, wenn festgestellt werden soll, ob zwischen zwei Punkten eine hydrologische Verbindung besteht. Bei dieser Fliessrichtungsbestimmung sind die Forderungen an die Eigenschaften der einzusetzenden Tracer geringer als bei der Bestimmung der Geschwindigkeit des unterirdischen Wassers. Von den Geschwindigkeiten des unterirdischen Wassers ist die Abstands-(Fliess)geschwindigkeit, die definiert ist durch das Verhaeltnis aus dem Abstand und der wahren Fliesszeit zwischen zwei in Bewegungsrichtung gelegenen Punkten, durch Tracermethoden zu bestimmen. (orig.)

  10. Radionuclides as tracers

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Importance of radioisotopes in medicine is because of their two characteristics: their biological behaviour is identical to their stable counterparts, and because they are radioactive their emissions can be detected by a suitable instrument. All isotopes of iodine will behave in the same way and will concentrate in the thyroid gland. There is no way of detecting the stable, natural iodine in the thyroid gland, but the presence of radioactive iodine can be detected externally in vivo by a detector. Thus, the radioactive iodine becomes a tracer, a sport of a spy, which mimics the behaviour of natural iodine and relays information to a detector. The radioactive tracers are popular because of the ease with which they can be detected in vivo and the fact that the measurement of their presence in the body can be in quantitative terms. The measurement can be very accurate and sensitive. Whenever the measurements can be done in vivo, the information is obtained in dynamic terms, as it is happening, as if the physiological events become transparent

  11. The study of cultural objects by nuclear and conventional techniques; Estudio de bienes culturales con tecnicas de caracterizacion nucleares y convencionales

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, Tulio A [Comision Nacional de Energia Atomica, General San Martin (Argentina). Centro Atomico Constituyentes

    2000-07-01

    A survey is given of the techniques that are used at the National Atomic Energy Commission of Argentina for the characterization and study of cultural and archaeological specimens. A short history of these activities is also given. (author)

  12. Labeling of fruitflies and their identification by tracer activation

    International Nuclear Information System (INIS)

    Haisch, A.; Forster, S.; Staerk, H.

    1975-01-01

    A technique was worked out to label and identify cherry fruit flies (Rhagoletic cerasi L.) in large numbers. For that purpose, the tracers dysprosium and samarium were mingled with a carrier substance (silica gel) which, mixed with silica sand, formed the substrate for emergence. The flies, the pupae of which were in this substrate, took up with their ptilinum-labeled silica gel during their crawling through the sand up to the surface. The tracer was detected after its activation by neutron irradiation

  13. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G.; ter Rahe, B.; Sloof, G.; de Hullu, J.; van der Velden, J.

    2004-01-01

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  14. Failure in the detection of the sentinel lymph node with a combined technique of radioactive tracer and blue dye in a patient with cancer of the vulva and a single positive lymph node

    NARCIS (Netherlands)

    Fons, G; ter Rahe, B; Sloof, G; de Hullu, J; van der Velden, J

    Background. In early stage vulvar cancer, the sentinel lymph node procedure with a radioactive tracer appears to be a promising new diagnostic tool to predict lymph node status. No detection failures have been published so far in vulvar cancer. We recently experienced failure in the detection of the

  15. Radon as geological tracer

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, T.; Anjos, R.M. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Fisica; Valladares, D.L.; Rizzotto, M.; Velasco, H.; Ayub, J. Juri [Universidad Nacional de San Luis (Argentina). Inst. de Matematica Aplicada San Luis (IMASL); Silva, A.A.R. da; Yoshimura, E.M. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica

    2012-07-01

    Full text: This work presents measurements of {sup 222}Rn levels performed in La Carolina gold mine and Los Condores tungsten mine at the province of San Luis, Argentina, today used for tourist visitation, and can evaluate the potential use of such radioactive noble gas as tracer or marker for geological processes in underground environments. By concentrations of {sup 40}K, {sup 232}Th and {sup 23}'8U were also measured in the walls of tunnels were determined the rocks mineral composition, what indicated that the mines have the same composition. In this sense, we used nuclear trace plastic detectors CR-39, gamma spectrometry of rock samples and Geiger-Muller (GM) monitors The patterns of radon gas transportation processes revealed that La Carolina could be interpreted through a model based on a radioactive gas confined into a single entrance tube, with constant cross section and air velocity. Los Condores, which has a second main entrance, could be interpreted through a model based on a radioactive gas confined into a two entrance tube, allowing a chimney effect for air circulation. The results showed the high potential of using {sup 222}Rn as a geological tracer. In what concerns the occupational hazard, in summer (time of more intense tourist activity in the mine) La Carolina presented a mean concentration of the radioactive noble gas that exceeds in four times the action level of 1,5 kBq m{sup -3} recommended by the International Commission of Radiological Protection (ICRP). The chimney effect shows the low mean concentration of radon in Los Condores. (author)

  16. Radon as geological tracer

    International Nuclear Information System (INIS)

    Lacerda, T.; Anjos, R.M.; Silva, A.A.R. da; Yoshimura, E.M.

    2012-01-01

    Full text: This work presents measurements of 222 Rn levels performed in La Carolina gold mine and Los Condores tungsten mine at the province of San Luis, Argentina, today used for tourist visitation, and can evaluate the potential use of such radioactive noble gas as tracer or marker for geological processes in underground environments. By concentrations of 40 K, 232 Th and 23 '8U were also measured in the walls of tunnels were determined the rocks mineral composition, what indicated that the mines have the same composition. In this sense, we used nuclear trace plastic detectors CR-39, gamma spectrometry of rock samples and Geiger-Muller (GM) monitors The patterns of radon gas transportation processes revealed that La Carolina could be interpreted through a model based on a radioactive gas confined into a single entrance tube, with constant cross section and air velocity. Los Condores, which has a second main entrance, could be interpreted through a model based on a radioactive gas confined into a two entrance tube, allowing a chimney effect for air circulation. The results showed the high potential of using 222 Rn as a geological tracer. In what concerns the occupational hazard, in summer (time of more intense tourist activity in the mine) La Carolina presented a mean concentration of the radioactive noble gas that exceeds in four times the action level of 1,5 kBq m -3 recommended by the International Commission of Radiological Protection (ICRP). The chimney effect shows the low mean concentration of radon in Los Condores. (author)

  17. Nutritional evaluation of leaves of some salt-tolerant tree species by assessing, in vitro, the ruminal microbial nitrogen and fermentation characteristics utilizing "1"5N tracer and gas production techniques

    International Nuclear Information System (INIS)

    Al-Masri, M.R.

    2014-04-01

    Leaves of some salt-tolerant tree species (Tamarix articulata Vahl., Tamarix aphylla (L) Karst, Acacia ampliceps Maslin, Casuarina equisetifolia L, Parkinsonia aculeate L, Eucaliptus camaldulensis Dahnhard) were evaluated in terms of microbial nitrogen (MN) and biomass (MBM) production after incubation with rumen fluid and 15N-tracer for 96 h in the absence or presence of polyethylene glycol (PEG, 6000). The characteristics of fermentation (initial gas produced from soluble fraction; a, gas production during incubation which produced from insoluble but fermentable fraction; b, potential gas production; a + b, fractional rate of gas production per hour; c) were assessed using an in vitro incubation technique with rumen fluid. Effective degradability (ED), short chain fatty acids (SCFA) and predicted daily intake (Y) were also estimated in leaves of the experimental tree species.The a + b values (mL/g DM) were highest (P<0.05) in A. ampliceps (191), lowest in T. articulate and C. equisetifolia (119), and intermediate in T. aphylla, E. camaldulensis and P. aculeate (158). E. camaldulensis, A. ampliceps and P. aculeate had higher (P<0.05) fractional rate of gas production (0.080/h) than other species (0.061/h). There was a positive correlation between SCFA concentrations and c and a + b values. The ratios of MN and MBM to effective degraded substrate and the values of MN and MBM were significantly higher (P<0.05) in P. aculeate and A. ampliceps compared with other species. Microbial nitrogen and MBM production were positively correlated with a + b, ED and SCFA.The addition of PEG to the plant samples incubated with rumen fluid at a ratio of 2:1 PEG: substrate increased the values of gas production, characteristics of fermentation, MN, MBM, SCFA, ED and Y. The response of leaves of the experimental tree species to PEG treatment in terms of increased gas production varied between species and tended to decline as incubation progressed, with the highest increase during the

  18. Short communication: Use of a portable, automated, open-circuit gas quantification system and the sulfur hexafluoride tracer technique for measuring enteric methane emissions in Holstein cows fed ad libitum or restricted.

    Science.gov (United States)

    Dorich, C D; Varner, R K; Pereira, A B D; Martineau, R; Soder, K J; Brito, A F

    2015-04-01

    The objective of this study was to measure enteric CH4 emissions using a new portable automated open-circuit gas quantification system (GQS) and the sulfur hexafluoride tracer technique (SF6) in midlactation Holstein cows housed in a tiestall barn. Sixteen cows averaging 176 ± 34 d in milk, 40.7 ± 6.1 kg of milk yield, and 685 ± 49 kg of body weight were randomly assigned to 1 out of 2 treatments according to a crossover design. Treatments were (1) ad libitum (adjusted daily to yield 10% orts) and (2) restricted feed intake [set to restrict feed by 10% of baseline dry matter intake (DMI)]. Each experimental period lasted 22d, with 14 d for treatment adaptation and 8d for data and sample collection. A common diet was fed to the cows as a total mixed ration and contained 40.4% corn silage, 11.2% grass-legume haylage, and 48.4% concentrate on a dry matter basis. Spot 5-min measurements using the GQS were taken twice daily with a 12-h interval between sampling and sampling times advanced 2h daily to account for diurnal variation in CH4 emissions. Canisters for the SF6 method were sampled twice daily before milking with 4 local background gas canisters inside the barn analyzed for background gas concentrations. Enteric CH4 emissions were not affected by treatments and averaged 472 and 458 g/d (standard error of the mean = 18 g/d) for ad libitum and restricted intake treatments, respectively (data not shown). The GQS appears to be a reliable method because of the relatively low coefficients of variation (ranging from 14.1 to 22.4%) for CH4 emissions and a moderate relationship (coefficient of determination = 0.42) between CH4 emissions and DMI. The SF6 resulted in large coefficients of variation (ranging from 16.0 to 111%) for CH4 emissions and a poor relationship (coefficient of determination = 0.17) between CH4 emissions and DMI, likely because of limited barn ventilation and high background gas concentration. Research with improved barn ventilation systems or

  19. Application of artificial radioactive tracers for groundwater flow

    International Nuclear Information System (INIS)

    Hamza, M.S.; Aly, A.I.M.; Swailem, F.M.; Nada, A.A.; Awad, M.A.

    1989-01-01

    In this work, the groundwater velocity was estimated by applying radioactive tracer techniques: the single well and the multiple well methods. In the first single well method, radioactive iodine-131 was injected in the well and the radioactivity was monitored with time. The groundwater flow was estimated as a function of the concentration dilution factor of the tracer taking into consideration the permeability of the filter screen and the aquifer. The second method (the multiple well technique) is based on direct measuring of the period of time the tracer needs to disperse from the injection well to one of receptor well arranged in a circle around the injection. The latter method was found to be more accurate and reliable and has also the advantage of determining the groundwater velocity and direction of flow as well. The limitations of the single well technique are discussed and a detailed comparison between single and multi-well techniques is given

  20. Air pollution tracer studies in the lower atmosphere (citations from the NTIS data base). Report for 1964-Jan 80

    International Nuclear Information System (INIS)

    Cavagnaro, D.M.

    1980-02-01

    The cited reports cover research on the use of tracers to study lower atmospheric air pollution movements. The tracer used include sulfur hexafluoride, krypton 85, carbon 14, and other radioactive isotopes. The studies cite the results and techniques used, tracer movement from nuclear power plants, industrial stacks, urban areas, and the detectors used in their measurement

  1. Techniques for the microbial community study in wastewater systems; Tecnicas utilizadas en el estudio de la comunidad microbiologica en sistemas de depuracion

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Gonzalez, M. C.; Fdez-Polanco, F.; Garcia Encina, P. A. [Universidad de Valladolid (Spain); Becares Mantecon, E. [Universidad de Leon (Spain)

    2003-07-01

    Activated sludge is community by an heterogenic organisms community, such as protozoa, metazoa, alga fungus and bacteria. Among these organisms bacteria are very important due to their rule in the nutrient (phosphate and nitrogen) and organic matter removal. so is important the study and knowledge of them, in order to understand how the wastewater systems works. To achieve this studies is necessary the characterization of the diverse bacterial groups (nitrifies, sulfate reducing, methanogenics etc.), thus it is essential the application of a rapid, reliable and precise method, like the molecular techniques that are commonly used in the wastewater studies. Among these techniques are F. I. S. H. (Florescence In Situ Hybridization). (Author) 27 refs.

  2. Optimization of Gamma-Ray Counting and Spectrometry in Biomedical Tracer Studies; Optimisation du Comptage et de la Spectrometrie des Rayons Gamma dans des Etudes Biomedicales Faites a l'Aide de Traceurs; Optimizatsiya gamma-scheta i spektrometrii gamma-luchej v biomeditsinskikh issledovaniyakh s pomoshch'yu indikatorov; Optimizacion del Recuento y de la Espectrometry Gamma en los Estudios Biomedicos con Indicadores

    Energy Technology Data Exchange (ETDEWEB)

    Guinn, V. P. [General Dynamics Corporation, San Diego, CA (United States)

    1965-10-15

    In biomedical tracer studies, especially in man and even more so in children and pregnant women, it is important to operate at the lowest possible level of administered radioisotope that is commensurate with the required precision and accuracy of the subsequent radioassay measurements. Similarly, with administered stable elements (as specified compounds) or enriched stable isotopes (again, in compound form), followed by radioactivation analysis of resulting samples, it is important from the toxicological standpoint to minimize the amounts of administered element. The problem of optimization of counting of one, two and three gamma-emitting radioisotopes, by Nal(Tl) scintillation counting, single-channel spectrometry and multichannel spectrometry, has been considered in some detail in these laboratories, with particular attention to single-, double-, or triple-tagging tracer studies with radioisotopes frequently used in biomedical studies: {sup 51}Cr, {sup 198}Au, {sup 75}Se, {sup 197}Hg, {sup 64}Cu, {sup 76}As, {sup 82}Br, {sup 59}Fe, {sup 60}Co, {sup 42}K, and {sup 24}Na. The same considerations apply to the widely-used thermal-neutron activation analysis determinations of the corresponding elements or enriched stable isotopes, so the results of these counting optimization calculations have a double usefulness. The calculations are based on a few reasonable assumptions made on practical biomedical considerations, namely: (1) small samples ({<=} 10 ml), (2) moderate counting periods (s 20 minutes), (3) modest allowable decay periods ({<=} 3 days) and (4) use of commercially available counting equipment and shielding. On this basis, the most sensitive methods of counting each of the aforementioned radioisotopes, and a number of pairs and trios of them, have been ascertained. The counting variables included in the considerations are: (1) type of Nal(Tl) crystal, i.e., solid or well-type, (2) size of Nal(Tl) crystal, up to a 5 in x 5 in size, (3) type of measuring

  3. Tracer dating and ocean ventilation

    International Nuclear Information System (INIS)

    Thiele, G.; Sarmiento, J.L.

    1990-01-01

    The interpretation of transient tracer observations depends on difficult to obtain information on the evolution in time of the tracer boundary conditions and interior distributions. Recent studies have attempted to circumvent this problem by making use of a derived quantity, age, based on the simultaneous distribution of two complementary tracers, such as tritium and its daughter, helium 3. The age is defined with reference to the surface such that the boundary condition takes on a constant value of zero. The authors use a two-dimensional model to explore the circumstances under which such a combination of conservation equations for two complementary tracers can lead to a cancellation of the time derivative terms. An interesting aspect of this approach is that mixing can serve as a source or sink of tracer based age. The authors define an idealized ventilation age tracer that is conservative with respect to mixing, and they explore how its behavior compares with that of the tracer-based ages over a range of advective and diffusive parameters

  4. Factores de éxito de un emprendimiento: Un estudio exploratorio con base en técnicas de data mining (Entrepreneurial success factors: An exploratory study based on Data Mining Techniques

    Directory of Open Access Journals (Sweden)

    María Messina

    2015-04-01

    Full Text Available El Centro de Emprendedurismo CCEEmprende de- sarrolla, desde 2007, un programa de apoyo a emprende- dores. Para mejorar su gestión, resulta de gran importancia analizar, en forma preliminar, los emprendimientos en una de dos categorías: éxito o fracaso. En este artículo se identifican los principales factores asociados al éxito de un emprendimiento y cómo se vincu- lan para anticipar el futuro del emprendimiento. Se presenta un caso de estudio con base en los datos de una encuesta realizada a emprendedores participantes del programa, aplicando técnicas de clasificación. Las dos técnicas utilizadas de data mining son árbol de decisión y regresión logística, en ambas se obtuvieron resultados coincidentes. Los hallazgos muestran que los dos elementos más relevantes para anticipar el éxito de un emprendimiento son contar con financiamiento y que, anteriormente, la situa- ción laboral del emprendedor sea trabajador independiente. Estos primeros resultados obtenidos en el estudio de caso revelan información útil acerca de las mejores formas de apoyo al emprendedor, cómo generar incentivos al em- prendedor y la definición de herramientas o actividades que incidan favorablemente en el éxito de los emprendimientos. Si bien desde la teoría o para otras realidades existe infor- mación sobre los factores que colaboran en la determina- ción del éxito, para la realidad del Uruguay no se identifican estudios similares.   Abstract  Since 2007, the CCEE Entrepreneurship Centre has developed a supporting program for entrepreneurs. A preliminary analysis to determine if the venture was successful or a failure is made to improve the program’s management . In this article, the authors identify the main factors associated with entrepreneurship’s success, and how they can anticipate entrepreneurship’s performance. The case study is based on a survey data applied to the Entrepreneurship Program participants. The two data mining

  5. The use of radioisotope tracers in the metallurgical industries

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    Radioisotope techniques have been widely used in the metallurgical industries for many years. They have been shown to be very suitable for studying large scale plant and, in many cases, they are the most suitable techniques for such investigations. Applications of radioisotope tracers to some specific metallurgical problems are discussed. (author)

  6. Meteorological tracers in regional planning

    International Nuclear Information System (INIS)

    Mueller, K.H.

    1974-11-01

    Atmospheric tracers can be used as indicators to study both the ventilation of an urban region and its dispersion meteorology for air pollutants. A correlation analysis applied to the space-time dependent tracer concentrations is able to give transfer functions, the structure and characteristic parameters of which describe the meteorological and topographical situation of the urban region and its surroundings in an integral manner. To reduce the number of persons usually involved in a tracer experiment an automatic air sampling system had to be developed

  7. Evaluación de dos técnicas de subtipificación molecular para el estudio de Pasteurella multocida Evaluation of two techniques of molecular subtyping to study Pasteurella multocida

    Directory of Open Access Journals (Sweden)

    G. A. Leotta

    2006-12-01

    Full Text Available Se determinó la tipibilidad, la reproducibilidad y el poder discriminatorio de ERIC-PCR y ApaI-PFGE para establecer la relación genética de cepas de Pasteurella multocida. Se estudiaron 49 cepas de diferente origen, subespecie, biotipo, grupo capsular, serotipo somático y perfil de resistencia antimicrobiana. Por ERIC-PCR se establecieron 31 patrones, los que presentaron entre 10 y 14 bandas en un rango comprendido entre 0,2 y 1,2 kb. Por ApaI-PFGE se detectaron 37 patrones de restricción, los cuales presentaron entre 7 y 15 bandas bien definidas de 34 a 450 kb. La tipibilidad de ERIC-PCR fue del 100% (T=1 y la de ApaI-PFGE del 94% (T=0,94. La reproducibilidad de ambas técnicas fue del 100% (R=1; sin embargo, el poder discriminatorio de ERIC-PCR fue 93% (D=0,93 y el de ApaI-PFGE 98% (D=0,98. Mediante ambas técnicas fue posible agrupar las cepas con relación epidemiológica y diferenciar claramente las cepas no relacionadas. Se demostró el valor de ERIC-PCR y ApaI-PFGE para complementar estudios epidemiológicos, principalmente si las cepas en estudio son analizadas por ambas técnicas.Typeability, reproducibility, and discriminatory power of ERIC-PCR and ApaI-PFGE to establish the genetic relation of P. multocida strains were determined. Forty-nine strains of different source, biotype, capsular group, somatic serotype, and resistance to antimicrobials were studied. By ERIC-PCR, 31 patterns were defined with 10 to 14 bands in a rank of 0.2 and 1.2 kb. By ApaI-PFGE, 37 restriction patterns were established with 7 to 15 bands of 34 to 450 kb. Typeability was 100% (T=1 for ERIC-PCR, and 94% (T=0.94 for ApaI-PFGE. Reproducibility of both techniques was 100% (R=1. Discriminatory power was 93% (D=0.93 for ERIC-PCR, and 98% (D=0.98 for ApaI-PFGE. By using both techniques, epidemiologically related strains were grouped, and unrelated strains were clearly differentiated. The value of ERIC-PCR and ApaI-PFGE as complements to epidemiologic studies

  8. Methods and instrumental techniques for the study of acidic water systems; Metodologias y tecnicas instrumentales para el estudio de sistemas de aguas acidas

    Energy Technology Data Exchange (ETDEWEB)

    Acero Salazar, P.; Asta Andres, M. P.; Torrento Aguerri, C.; Gimeno Serrano, M. J.; Auque Sanz, L. F.; Gomez Jimenez, J. B.

    2011-07-01

    From a geochemical point of view acidic waters are very complex systems in which many interaction processes take place between surface and ground waters, gases (particularly atmospheric oxygen), acid-generating minerals, solid phases responsible for the natural attenuation of elements in solution and also many types of biological activity. Owing to this high complexity, the quality and reliability of any geochemical study focusing on this type of system will depend largely upon the use of appropriate methods of sampling, preservation and analysis of waters, minerals, gases and biological samples. We describe here the main methods and techniques used in geochemical studies of acid waters associated with sulphide mineral environments, taking into account not only the various sample types but also the features of the main types of system (open pits, tailings ponds, acid streams etc.). We also explain the main applications and limitations of each method or technique and provide references to earlier technical and scientific studies in which further information can be obtained. (Author) 97 refs.

  9. Nuclear techniques in industry

    International Nuclear Information System (INIS)

    Hammad, F.H.

    1994-01-01

    Nuclear techniques are utilized in almost every industry. The discussion in this paper includes discussions on tracer methods and uses nucleonic control systems technology; non-destructive testing techniques and radiation technology. 1 fig., 2 tabs

  10. Tracer studies with aortic infusion result in improper tracer distribution

    International Nuclear Information System (INIS)

    Wisneski, J.A.; Brooks, G.A.; Neese, R.A.; Stanley, W.C.; Morris, D.L.; Gertz, E.W.

    1986-01-01

    It has been suggested that lactate turnover can be accurately assessed by infusing radioactive lactate tracer into the aorta and sampling blood in the vena cava. However, there may be streaming of newly infused tracer in the aorta, resulting in a nonuniform arterial specific activity (SA). Furthermore vena caval blood may not be representative of mixed venous blood. The authors examined this problem in 7 anesthetized dogs with sampling catheters in the pulmonary (PA), carotid (CA), and femoral (FA) arteries, and the superior (SVC) and inferior (IVC) vena cavi. [1- 14 C]lactate was continuously infused into the left ventricle through a catheter introduced through the femoral artery. The same SA (dpm/μmol) was found in the CA and FA, indicating adequate mixing of newly infused tracer with trace. Three dogs showed differences between SVC, IVC and PA, suggesting a mixed venous sample can not be obtained from the VC. When the catheter was moved into the aorta, wide differences in SA appeared between the CA and FA, clearly reflecting streaming of tracer. These differences also appeared in the SVC and IVC. In conclusion, adequate mixing does not occur between tracer and trace in arterial blood with aortic infusion. Further, VC sampling will not give a consistent mixed venous SA. Therefore, for practical reasons, aortic tracer infusion with vena caval sampling will lead to erroneous turnover values

  11. The use of radioactive tracers in lubrication and wear research; Emploi des indicateurs radioactifs dans les recherches sur la lubrification et l'usure; Ispol'zovanie mechenykh atomov pri issledovanii voprosov smazki i iznosa; Utilizacion de los indicadores radiactivos en los estudios sobre la lubricacion y el desgaste

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, R B; Grunberg, L; Milne, A A; Wright, K H.R. [Lubrication, Wear and Mechanical Engineering Aspects of Corrosion Division, National Engineering Laboratory, Thorntonhall, Glasgow (United Kingdom)

    1962-01-15

    In many lubrication and wear problems, processes occurring on a very small scale have to be studied and the great sensitivity of radioactive tracer methods has been successfully applied. Several examples of such applications are cited from the work of the Lubrication and Wear Division of the National Engineering Laboratory in the United Kingdom. The quantitative relation between metal transfer and boundary friction is studied as a function of sliding velocity, surface roughness and the presence of lubricants. In order to study the distribution of wear, cast iron plugs containing Ir{sup 192} are inserted in the liners of a Diesel engine and the radioactivity present in oil samples is measured. Radioactive iron and iron oxide particles are used to study then role in the wear process. The reactivity of strained metal surface is studied with the aid of C{sup 14}- labelled stearic acid and of S{sup 35} in solution. The reaction rates of gear oil additive are being studied by passing short electric-current pulses through metal wires immersed in solutions of compounds labelled with S{sup 35} and P{sup 32}. The build-up of anti-wear films on the surface of gear teeth is being studied as a function of lead, speed and running time. A problem encountered in many of these applications is the conversion of the measured activity into absolute quantities of materials present in surface films or in wear debris. Calibration methods have been developed for this purpose. (author) [French] Pour nombre de problemes relatifs a la lubrification et a l'usure, ou l'on doit etudier des processus se produisant a tres petite echelle, la methode des indicateurs radioactifs, qui presente l'avantage d'etre tres sensible, a donne de bons resultats. Le memoire cite plusieurs exemples d'applications de ce genre, tires des travaux de la Division de la lubrification et de l'usure du National Engineering Laboratory (Royaume-Uni). La relation quantitative entre le transfert de metal et la friction de

  12. Tracer transport in fractured rocks

    International Nuclear Information System (INIS)

    Tsang, C.F.; Tsang, Y.W.; Hale, F.V.

    1988-07-01

    Recent interest in the safety of toxic waste underground disposal and nuclear waste geologic repositories has motivated many studies of tracer transport in fractured media. Fractures occur in most geologic formations and introduce a high degree of heterogeneity. Within each fracture, the aperture is not constant in value but strongly varying. Thus for such media, tracer tends to flow through preferred flowpaths or channels within the fractures. Along each of these channels, the aperture is also strongly varying. A detailed analysis is carried out on a 2D single fracture with variable apertures and the flow through channels is demonstrated. The channels defined this way are not rigidly set pathways for tracer transport, but are the preferred flow paths in the sense of stream-tubes in the potential theory. It is shown that such variable-aperture channels can be characterized by an aperture probability distribution function, and not by the exact deterministic geometric locations. We also demonstrate that the 2D tracer transport in a fracture can be calculated by a model of a system of 1D channels characterized by this distribution function only. Due to the channeling character of tracer transport in fractured rock, random point measurements of tracer breakthrough curves may give results with a wide spread in value due to statistical fluctuations. The present paper suggests that such a wide spread can probably be greatly reduced by making line/areal (or multiple) measurements covering a few spatial correlation lengths. 13 refs., 11 figs., 1 tab

  13. Comparative study between two austenitic steels with the EPR (Electrochemical Potentiokinetic Reactivation) technique.; Estudio comparativo entre dos aceros austeniticos mediante la tecnica EPR (Reactivacion Electroquimica Potenciocinetica)

    Energy Technology Data Exchange (ETDEWEB)

    Guillen M, A N

    1997-09-01

    In the mid 19704s, the intergranular corrosion with stress corrosion cracking (IGSCC) have been identified as a greater problem in Boiling Water Reactors BWR in several places of the world. The Electrochemical Potentiokinetic Reactivation - Single Loop (EPR-SL) test and the Double Loop (EPR-DL) test, were developed as methods for measuring the Degree of Sensitization (DOS), show sensitised materials at subject to Intergranular Corrosion. In Mexico, the Laguna Verde4s reactor is BWR type and many of its principal components was built with AISI 304 stainless steels, while that in VVER reactors as well as Juragua4s reactor in Cuba is used 321 Stainless stell in its Russian equivalent designation 08Ch18N10T. In this work, were studied 304 and 08Ch18N10T stainless steels by means of EPR-SL, EPR-DL and ASTM A-262 techniques, they have been found a good correlation for 304 steel but not in 08Ch18N10T steel and was proposed one modification in the criterion by the evaluation on the sensitisation in this steels. Finally, both materials were welded with procedures used in the nuclear industry, by Slow Strain Rate Test (SSRT) to determine the Stress Corrosion Cracking SCC susceptibility, and subsequently the susceptibility to localized corrosion was studied by means of Cyclic Polarization test and the uniform corrosion rate in a solution with chlorides by the Tafel plot, Potentiodynamic Anodic Polarization Resistance. (Author).

  14. Lanthanide-based fluorescent tracers in complex media

    International Nuclear Information System (INIS)

    Brichart, Thomas

    2014-01-01

    Tracers are objects allowing the determination of the position or the distribution of a product; tracers are currently used in a great variety of domains. Despite the fact that each field has it's own specifications, it is possible to find tracers in medicine (contrast agents), anti-counterfeiting or geological exploration. We have developed lanthanide complex tracers for oil field injection waters. Those tracers, derived from the DOTA, have been detected at concentration lower than 1 ppb, thanks to a simple and compact apparatus. This detection has been made possible by the use of time-resolved fluorescence spectroscopy, this technique allows us to get rid of the background noise created by the intrinsic fluorescence of oil residues that are present in production waters. We also demonstrated how we can, through a reverse microemulsion synthesis, encapsulate several different dyes inside a single nanoparticle composed of a gold core and a silica shell. We showed as well, how those particles can be used as smart tracers to gather data, such as temperature, pH, solvents, etc. inside the well. Finally the use of lanthanides and scale inhibitors properties allowed us to create a simple and fast dosing protocol of such scale inhibitors in injection waters. This dosage will then allow the quick adjustment of their concentration inside each well. (author) [fr

  15. Root zone effects on tracer migration in arid zones

    International Nuclear Information System (INIS)

    Tyler, S.W.; Walker, G.R.

    1994-01-01

    The study of groundwater recharge and soil water movement in arid regions has received increased attention in the search for safe disposal sites for hazardous wastes. In passing through the upper 1 to 2 m of most soil profiles, tracers indicative of recharge such as Cl, 2 H, 18 O, Br, 3 H, and 56 Cl are subjected to a wide range of processes not encountered deeper in the profile. This transition zone, where water enters as precipitation and leaves as recharge, is often ignored when environmental tracers are used to estimate deep soil water flux and recharge, yet its effect may be profound. In this work, we reexamine the processes of root extraction and its effect on the velocity and distribution of tracers. Examples are presented for idealized conditions, which show clearly the relation between the root zone processes and the deep drainage or recharge. The results indicate that, when recharge is small and root zone processes are not accounted for, tracer techniques can significantly overestimate recharge until the tracer has moved well below the root zone. By incorporating simple models of root zone processes, a clearer understanding of tracer distributions and a more accurate estimate of recharge can then be made. 11 refs., 9 figs

  16. The use of synthetic colloids in tracer transport experiments in saturated rock fractures

    International Nuclear Information System (INIS)

    Reimus, P.W.

    1995-08-01

    Studies of groundwater flow and contaminant transport in saturated, fractured geologic media are of great interest to researchers studying the potential long-term storage of hazardous wastes in or near such media. A popular technique for conducting such studies is to introduce tracers having different chemical and physical properties into a system and then observe the tracers at one or more downstream locations, inferring flow and transport mechanisms from the breakthrough characteristics of the different tracers. Many tracer studies have been conducted in saturated, fractured media to help develop and/or refine models capable of predicting contaminant transport over large scales in such media

  17. Radioisotope tracer applications in industry

    International Nuclear Information System (INIS)

    Rao, S.M.

    1987-01-01

    Radioisotope tracers have many advantages in industrial trouble-shooting and studies on process kinetics. The applications are mainly of two types: one leading to qualitative (Yes or No type) information and the other to quantitative characterisation of flow processes through mass balance considerations and flow models. ''Yes or No'' type methods are mainly used for leakage and blockage locations in pipelines and in other industrial systems and also for location of water seepage zones in oil wells. Flow measurements in pipelines and mercury inventory in electrolytic cells are good examples of tracer methods using the mass balance approach. Axial dispersion model and Tanks-in-Series model are the two basic flow models commonly used with tracer methods for the characterisation of kinetic processes. Examples include studies on flow processes in sugar crystallisers as well as in a precalcinator in a cement plant. (author). 18 figs

  18. Using radioactive tracers for the evaluation of industrial equipment

    International Nuclear Information System (INIS)

    Brandao, Luis Eduardo Barreira; Sa, Lidia Vasconcellos de; Sousa, Alvaro Serafim F. de

    2000-01-01

    This paper presents the radioactive tracer technique, giving as example some cases of the possible utilization developed by the Nuclear Engineering Institute, RJ, BR (Argonaut reactor) and through charged particle (CV-28 cyclotron), and also his production and aspects of radiological safety

  19. Interest of radioactive tracers in fruit cultivation research

    International Nuclear Information System (INIS)

    Ferauge, M.T.; Dreze, Ph.

    1976-01-01

    The authors report some results related to the use of tracer techniques applied to nutrition and physiological diseases of fruit trees. Penetration and fate of several mineral and organic elements either by root system or by aerial parts of the trees are studied. (J.C.)

  20. In-situ testing methods using radioactive tracers

    International Nuclear Information System (INIS)

    Sauzay, G.

    1976-01-01

    Some typical applications of tracer techniques in hydrology are presented: study of the extraction of sands and gravels in a estuary; in-situ study of the transport of sediments by the swell at a depth ranging from 8 to 22m; study of the transport of sands on the site Bonne Anse - Saint Palais [fr

  1. Stable isotope tracers and exercise physiology: past, present and future.

    Science.gov (United States)

    Wilkinson, Daniel J; Brook, Matthew S; Smith, Kenneth; Atherton, Philip J

    2017-05-01

    Stable isotope tracers have been invaluable assets in physiological research for over 80 years. The application of substrate-specific stable isotope tracers has permitted exquisite insight into amino acid, fatty-acid and carbohydrate metabolic regulation (i.e. incorporation, flux, and oxidation, in a tissue-specific and whole-body fashion) in health, disease and response to acute and chronic exercise. Yet, despite many breakthroughs, there are limitations to 'substrate-specific' stable isotope tracers, which limit physiological insight, e.g. the need for intravenous infusions and restriction to short-term studies (hours) in controlled laboratory settings. In recent years significant interest has developed in alternative stable isotope tracer techniques that overcome these limitations, in particular deuterium oxide (D 2 O or heavy water). The unique properties of this tracer mean that through oral administration, the turnover and flux through a number of different substrates (muscle proteins, lipids, glucose, DNA (satellite cells)) can be monitored simultaneously and flexibly (hours/weeks/months) without the need for restrictive experimental control. This makes it uniquely suited for the study of 'real world' human exercise physiology (amongst many other applications). Moreover, using D 2 O permits evaluation of turnover of plasma and muscle proteins (e.g. dynamic proteomics) in addition to metabolomics (e.g. fluxomics) to seek molecular underpinnings, e.g. of exercise adaptation. Here, we provide insight into the role of stable isotope tracers, from substrate-specific to novel D 2 O approaches, in facilitating our understanding of metabolism. Further novel potential applications of stable isotope tracers are also discussed in the context of integration with the snowballing field of 'omic' technologies. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  2. PIV tracer behavior on propagating shock fronts

    International Nuclear Information System (INIS)

    Glazyrin, Fyodor N; Mursenkova, Irina V; Znamenskaya, Irina A

    2016-01-01

    The present work was aimed at the quantitative particle image velocimetry (PIV) measurement of a velocity field near the front of a propagating shock wave and the study of the dynamics of liquid tracers crossing the shock front. For this goal, a shock tube with a rectangular cross-section (48  ×  24 mm) was used. The flat shock wave with Mach numbers M  =  1.4–2.0 propagating inside the tube channel was studied as well as an expanding shock wave propagating outside the channel with M  =  1.2–1.8 at its main axis. The PIV imaging of the shock fronts was carried out with an aerosol of dioctyl sebacate (DEHS) as tracer particles. The pressures of the gas in front of the shock waves studied ranged from 0.013 Mpa to 0.1 MPa in the series of experiments. The processed PIV data, compared to the 1D normal shock theory, yielded consistent values of wake velocity immediately behind the plain shock wave. Special attention was paid to the blurring of the velocity jump on the shock front due to the inertial particle lag and peculiarities of the PIV technique. A numerical algorithm was developed for analysis and correction of the PIV data on the shock fronts, based on equations of particle-flow interaction. By application of this algorithm, the effective particle diameter of the DEHS aerosol tracers was estimated as 1.03  ±  0.12 μm. A number of different formulations for particle drag were tested with this algorithm, with varying success. The results show consistency with previously reported experimental data obtained for cases of stationary shock waves. (paper)

  3. Improvement of the qualitative and quantitative detection of simultaneously present fluorescent tracers by systematic sample treatment

    International Nuclear Information System (INIS)

    Behrens, H.

    1982-01-01

    The selective instrumental detection of individual fluorescent tracers in mixtures containing further fluorescent dyes is limited by spectral interferences. Therefore additional separations or other suitable procedures have to be included into the analytic technique. With the method described below, the respective tracer to be detected remains with its initial concentration in the sample and is analysed under the appropriate conditions, whereas the interfering tracers are separated or suppressed. The techniques applied for this base on the facts that 1) the fluorescence intensity of the tracers varies differently when the pH-value changes; 2) the tracers show different absorption behaviour and 3) they provide different degrees of light sensitivity. The procedures permit for example to detect uranin when eosin is present in a higher concentration or to detect eosin when amidorhodamin G is present. (orig.) [de

  4. Tracers of cancer cells in nuclear oncology

    International Nuclear Information System (INIS)

    Tamgac, F.; Baillet, G.; Moretti, J.L.; Safi, N.; Weinmann, P.; Beco, V. de

    1997-01-01

    Evaluating the extent of disease is important in planning cancer treatment. Different types of tracers are used in vivo to diagnose tumors and these tracers can give supplementary information on the differentiation degree of tumors and response to therapy. (authors)

  5. Analysis of infiltration through mill tailings using a bromide tracer

    International Nuclear Information System (INIS)

    Lewis, G.J.; Stephens, D.B.

    1985-01-01

    Infiltration of precipitation into tailings impoundments as a means of recharge to underlying materials is often considered insignificant, particularly in arid and semi-arid environments. A series of experiments was performed to investigate the behavior of infiltrated precipitation into tailing soils, by the use of a bromide tracer. A bromide tracer was applied to the surface of columns driven into the tailings to monitor downward advancement of tracer-laden water. Controlled laboratory experiments on the behavior of the bromide tracer under varying precipitation events and initial soil moisture contents were also conducted. Results indicate that a definite downward migration of infiltrated precipitation occurs, particularly with large magnitude precipitation events, and that, eventually, some fraction of the infiltrated precipitation may continue downward below the zone affected by evaporation. The use of an artificially applied bromide tracer to monitor depth of infiltration of precipitation is a simple, safe technique that can provide valuable information for long-term tailings management strategies at low cost

  6. Estudio comparativo de 2 técnicas quirúrgicas para la cirugía del pterigión primario Comparative study of 2 surgical techniques for the operation of primary Pterygium

    Directory of Open Access Journals (Sweden)

    Leonor R Díaz Alfonso

    2000-12-01

    Full Text Available Realizamos un estudio comparativo de 2 técnicas quirúrgicas para la cirugía del Pterigión Primario. Nuestra muestra estuvo conformada por 100 pacientes portadores del Pterigión Primario Grado II, que fueron enviados a una consulta creada al efecto, según los criterios de inclusión y exclusión establecidos. Les fue llenada una encuesta. Según el método de muestreo aleatorio por conglomerados en el tiempo del Programa ALE de la Facultad de Ciencias Médicas de Cienfuegos. A 50 de estos pacientes se les realizó la autoplastia conjuntival y al resto la exéresis simple; estos pacientes se siguieron en consulta evolutivamente durante 6 meses. Comparamos los resultados obtenidos con la utilización de las 2 técnicas y encontramos que la autoplastia conjuntival resultó ser más eficaz; pues la frecuencia de complicaciones fue solamente del 6,0 %; mientras que con la técnica convencional la recidiva es del 20,0 %; por lo que esperamos resultados alentadores en cuanto al tratamiento del Pterigión PrimarioA comparative study of 2 surgical techniques used in the operation of primary Pterygium was conducted. Our sample was composed of 100 patients carriers of primary Pterygium degree II that were referred to to the consulting room created to this end according to the established criteria of inclusion and exclusion. Patients were surveyed according to the method of randomized sampling by clusters at the time of the implementation of the ALE Program in the Faculty of Medical Sciences of Cienfuegos. 50 of these patients underwent Conjunctival Autoplasty and the rest Simple Exeresis. The evolution of these patients was followed-up at the consulting room during 6 months. The results obtained on using both techiques were compared and we found that the Conjunctival Autoplasty was more efficient, since the frequence of complications was just 6.0%, whereas with the conventional technique the relapse was 20.0%. We hope to attain encouraging results in

  7. de estudios observacionales

    Directory of Open Access Journals (Sweden)

    Erik von Elm

    2008-01-01

    un documento de explicación y elaboración al que puede accederse libremente en los sitios web de PLoS Medicine, Annals of Internal Medicine y Epidemiology. Esperamos que la declaración STROBE contribuya a mejorar la calidad de la publicación de los estudios observacionales.

  8. Underground flux studies in waste basin of CIPC using natural and artificial tracers - v.1

    International Nuclear Information System (INIS)

    Minardi, P.S.P.

    1982-10-01

    Underground flux studies in waste basin of CIPC is presented, with the description of the regions and the wells, the techniques with artificial tracers and the results and conclusion, based in field campaign realized till february/82. (author)

  9. ESTUDIO DE SERIES TEMPORALES DE CONTAMINACIÓN AMBIENTAL MEDIANTE TÉCNICAS DE REDES NEURONALES ARTIFICIALES TIME SERIES ANALYSIS OF ATMOSPHERE POLLUTION DATA USING ARTIFICIAL NEURAL NETWORKS TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Giovanni Salini Calderón

    2006-12-01

    Full Text Available Se diseñó una red neuronal artificial (RNA para hacer predicciones de valores de concentraciones horarias de material particulado fino en la atmósfera. El estudio está basado en los datos de tres años de series de tiempo de pm2.5 (material particulado suspendido de 2,5 micrones de diámetro, obtenidos en una estación céntrica de la Red MACAM de la ciudad de Santiago de Chile, entre los años 1994 y 1996. Para obtener el espaciamiento óptimo de los datos, así como el número de datos hacia atrás necesarios para pronosticar el valor futuro, se aplicaron dos test estándar usados en estudio de sistemas dinámicos, como Información Mutua promedio (AMI y Falsos Vecinos más Cercanos (FNN. De esta manera se encontró que lo más conveniente era considerar como entrada los datos de PM2.5 cada seis horas durante un día (cuatro datos, y en base a ellos predecir el dato siguiente. Una vez fijo el número de variables de entrada y elegida la variable a pronosticar, se diseñó un modelo predictivo basado en la técnica de RNA. El tipo de modelo de RNA usado fue uno de multicapas, alimentado hacia adelante y entrenado mediante la técnica de propagación hacia atrás. Se probaron redes sin capa oculta y con una y dos capas ocultas. El mejor modelo resultó ser con una capa oculta, a diferencia de lo obtenido en trabajo anterior que reportaba que la red sin capa oculta era más eficiente. Los resultados fueron más precisos que los obtenidos con un modelo de persistencia (el valor en seis horas más será el mismo que el actual.An artificial neural network for the forecasting of concentrations of fine particulate matter in the atmosphere was designed. The data set analyzed corresponds to three years of pm2.5 time series (particulate matter in suspension with aerodynamic diameter less than 2,5 microns, measured in a station that belongs to Santiago's monitoring network (Red MACAM and is located near downtown. We consider measurements of

  10. New SPECT tracers: Example of tracers of proteoglycans and melanin

    International Nuclear Information System (INIS)

    Cachin, F.; Mestas, D.; Kelly, A.; Merlin, C.; Veyre, A.; Maublant, J.; Cachin, F.; Chezal, J.M.; Miot-Noirault, E.; Moins, N.; Auzeloux, P.; Vidal, A.; Bonnet-Duquennoy, M.; Boisgard, S.; D'Incan, M.; Madelmont, J.C.; Maublant, J.; Boisgard, S.; D'Incan, M.; Redini, F.; Filaire, M.

    2009-01-01

    The majority of research program on new radiopharmaceuticals turn to tracers used for positron emission tomography (PET). Only a few teams work on new non fluorine labeled tracers. However, the coming of SPECT/CT gamma cameras, the arrival of semi-conductors gamma cameras should boost the development of non-PET tracers. We exhibit in this article the experience acquired by our laboratory in the conception and design of two new non fluorine labelled compounds. The 99m Tc-N.T.P. 15-5 (N.T.P. 15-5 for N-[tri-ethyl-ammonium]-3-propyl-[15]ane-N5) which binds to proteoglycans could be used for the diagnosis and staging of osteoarthritis and chondrosarcoma. The iodo benzamides, specific to the melanin, are nowadays compared to 18 F-fluorodeoxyglucose in a phase III clinical trial for the diagnosis and detection of melanoma metastasis. Our last development focus on N-[2-(diethyl-amino)ethyl]-4 and 2-iodo benzamides respectively B.Z.A. and B.Z.A.2 hetero-aromatic analogues usable for melanoma treatment. (authors)

  11. The fluorescent tracer experiment on Holiday Beach near Mugu Canyon, Southern California

    Science.gov (United States)

    Kinsman, Nicole; Xu, J. P.

    2012-01-01

    After revisiting sand tracer techniques originally developed in the 1960s, a range of fluorescent coating formulations were tested in the laboratory. Explicit steps are presented for the preparation of the formulation evaluated to have superior attributes, a thermoplastic pigment/dye in a colloidal mixture with a vinyl chloride/vinyl acetate copolymer. In September 2010, 0.59 cubic meters of fluorescent tracer material was injected into the littoral zone about 4 kilometers upcoast of Mugu submarine canyon in California. The movement of tracer was monitored in three dimensions over the course of 4 days using manual and automated techniques. Detailed observations of the tracer's behavior in the coastal zone indicate that this tracer successfully mimicked the native beach sand and similar methods could be used to validate models of tracer movement in this type of environment. Recommendations including how to time successful tracer studies and how to scale the field of view of automated camera systems are presented along with the advantages and disadvantages of the described tracer methodology.

  12. Study of the flooding and dehydration processes of a PEM fuel cell using the EIS technique; Estudio de los procesos de inundacion y deshidratacion en una celda de combustible tipo PEM mediante la tecnica EIS

    Energy Technology Data Exchange (ETDEWEB)

    Loyola-Morales, F.; Cano-Castillo, U. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)]. E-mail: feloyola@yahoo.com.mx

    2009-09-15

    In this work, a study was conducted of the flooding and dehydration processes of a PEM fuel cell using the EIS technique. The experiments were conducted in a 50 cm{sup 2} cell. The gradual flooding of the system was induced by operating the cell at a potential of 0.3 V and maintaining the gas outlet closed (that is, stoichiometry of 1 for the anode (H{sub 2}) and the cathode (O{sub 2})) to enable the water produced by the reaction to accumulate inside. The gradual dehydration was induced by operating the cell at a potential of 0.3V and establishing a oxidized gas flow at a stoichiometry of 4. EIS tests were applied throughout both processes. The results showed that the EIS technique is highly sensitive for the analysis of the different degrees of the flooding processes by monitoring variations in the imaginary components of total impedance (Z{sup )} or the phase angle ({theta}). For low degrees of flooding, the technique had good sensitivity, between 1 and 6 Hz, while at high degrees of flooding the technique's greatest sensitivity was limited to a range between 1 and 2 Hz. In the case of the dehydration process of the system, the results showed that this type of process can be analyzed for variations in the value of the real component (Z{sup '}) as well as for the imaginary component of total impedance and variations in the phase angle. The analysis of dehydration with Z{sup '} was possible at a rather wide range, from 100 to 1000 Hz; with Z{sup }or {theta} it was only possible at a range of 20 to 200 Hz. [Spanish] En el presente trabajo, se llevo a cabo el estudio de los procesos de inundacion y deshidratacion de una celda de combustible tipo PEM mediante la tecnica EIS. Los experimentos fueron realizados en una celda de 50 cm{sup 2}. La inundacion gradual del sistema se indujo operando la celda a un potencial de 0.3 V de celda y manteniendo la salida de gases cerrada (i. e. estequiometria de 1 tanto en anodo (H{sub 2}) como en catodo (O{sub 2

  13. Fifty years of radiochemical tracers

    International Nuclear Information System (INIS)

    Evans, E.A.

    1992-01-01

    During the past 50 years radiochemical tracers, usually in the form of isotopically labelled organic compounds, have been essential tools to further advance our knowledge at the frontiers of a great variety of scientific developments in the life sciences. This plenary lecture reviews necessarily selected highlights in the synthesis and applications of such radiochemical tracers. Included are examples where important advances, made possible by using radiochemicals, have contributed to improving the quality of life on this planet. The principal radioisotopes involved, 14 C, 3 H, 35 S, 32 P, 125 I, are all relatively safe to handle and are commercially available at maximum theoretical specific activity (carrier free). The compounds labeled with these radioisotopes are used in many fields of research which include biosynthesis and biotechnology studies, cell biology, drug metabolism, clinical research and environmental applications, and are briefly reviewed. (author). 55 refs

  14. The Accurate Particle Tracer Code

    OpenAIRE

    Wang, Yulei; Liu, Jian; Qin, Hong; Yu, Zhi

    2016-01-01

    The Accurate Particle Tracer (APT) code is designed for large-scale particle simulations on dynamical systems. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and non-linear problems. Under the well-designed integrated and modularized framework, APT serves as a universal platform for researchers from different fields, such as plasma physics, accelerator physics, space science, fusio...

  15. New SPECT and PET dementia tracers

    International Nuclear Information System (INIS)

    Vergote, J.; Chalon, S.; Emond, P.; Vercouillie, J.; Guilloteau, D.; Vergote, J.; Guilloteau, D.; Pappata, J.S.

    2009-01-01

    Single photon emission tomography (SPECT) and positron emission tomography (PET) are techniques to study in vivo neurotransmitter systems, neuro inflammation and amyloid deposits in normal human brain and in dementia. These methods used to explore the integrity of dopaminergic, cholinergic and serotonergic systems in Alzheimer's disease and in other dementias allowed to understand how the neurotransmission was modified in these disorders. Progress in the understanding of pathophysiological and clinical signs of dementia requires an evolution of the radioligands used to carry out an increasingly early and differential diagnosis in addition to monitoring the progression of disease and the effects of therapies. New emerging radiotracers for neuro inflammation or amyloid deposits are essential. In this article, new SPECT and PET tracers are presented. (authors)

  16. Estudio de Factibilidad de Técnicas Vibroacústicas en la Detección de Discontinuidades en Metales. (Parte I. // Vibroacoustical techniques in metals discontinuity detection (part I.

    Directory of Open Access Journals (Sweden)

    F. de la Torre. Silva

    1999-07-01

    Full Text Available En este trabajo se presenta un estudio de factibilidad para la detección de discontinuidades en metales a partir de la aplicación detécnicas de ensayo vibroacústicas mediante la excitación sinusoidal e impulsiva. El análisis simultáneo que puede ser realizado a laseñal de entrada y de salida de un elemento metálico, reportaría una descripción del sistema en cuanto a sus propiedades dinámicasfundamentales, como lo son el caso de la Función Respuesta de Frecuencias y la Respuesta Impulsiva. Además, el uso de la Funciónde Correlación Cruzada, permitiría cuantificar el tiempo de propagación de la señal entre la entrada y la salida, para variaciones dediscontinuidades. El empleo de un Instrumento Virtual, sería la herramienta para la realización del análisis de señales. Se plantea unmodelo físico matemático teórico a partir del empleo del Método de los Elementos Finitos, implementado por el software MSC/PAL,el cual permitirá corroborar los resultados brindados por el diseño experimental, así como, estudiar dinámicamente el sistema objetode análisis.Palabras claves: factibilidad, fractura, vibroacústica, diagnóstico.__________________________________________________________________AbstractIn this work is presented a feasibility study for the discontinuities detection in metals as of the application of trial techniques vibraacoustic through the excitement sinusoidal and impulsive. The simultaneous analysis that it can be accomplished to the entry sign andof exit of a metallic element, would report a description of the system concerning their/its fundamental dynamic properties, as are thecase of the function frequencies response and impulsive response. Furthermore, the use of the correlation function crusade, wouldpermit quantify the spread time of the sign between the entry and the exit, for discontinuity variations. The employment of a virtualinstrument, would be the tool for the accomplishment of the signs analysis

  17. Relative distance between tracers as a measure of diffusivity within moving aggregates

    Science.gov (United States)

    Pönisch, Wolfram; Zaburdaev, Vasily

    2018-02-01

    Tracking of particles, be it a passive tracer or an actively moving bacterium in the growing bacterial colony, is a powerful technique to probe the physical properties of the environment of the particles. One of the most common measures of particle motion driven by fluctuations and random forces is its diffusivity, which is routinely obtained by measuring the mean squared displacement of the particles. However, often the tracer particles may be moving in a domain or an aggregate which itself experiences some regular or random motion and thus masks the diffusivity of tracers. Here we provide a method for assessing the diffusivity of tracer particles within mobile aggregates by measuring the so-called mean squared relative distance (MSRD) between two tracers. We provide analytical expressions for both the ensemble and time averaged MSRD allowing for direct identification of diffusivities from experimental data.

  18. Statistical dynamic imaging of RI-labeled tracer from list-mode PET data

    International Nuclear Information System (INIS)

    Tanimoto, Michiaki; Kuroda, Yoshihiro; Oshiro, Osamu; Watabe, Hiroshi; Kuroda, Tomohiro

    2009-01-01

    Positron emission tomography (PET) can be used in physiological analysis to illustrate physiological states by visualizing the accumulation of radioisotope (RI)-labeled tracer in specific organs or tissues. PET obtains spatio-temporal statistics in the form of list-mode data. However, conventional imaging techniques, which sum up list-mode data over a given time period, cannot depict detailed temporal dynamics of the RI-labeled tracer. In this study, a spatio-temporal analysis approach was employed to visualize the temporal flow dynamics of RI-labeled tracer from the obtained list-mode data. Experiments to assess the visualization of simulated RI-labeled tracer dynamics as well as RI-labeled tracer dynamics in a vascular phantom showed that the proposed method successfully depicted detailed temporal flow dynamics that could not be visualized using conventional methods. (author)

  19. Estudio de validez predictiva

    OpenAIRE

    Barquero-Segura, José Antonio

    2003-01-01

    Proyecto de investigación Este documento es un informe ejecutivo de la información obtenida de los estudios sobre la validez predictiva de los parámetros de selección de estudiantes y su relación con el rendimiento académico. En él se presenta una síntesis de información más relevante obtenida en los últimos 17 años.

  20. An overview of application of bayesian classifier approach in radioactive tracer technology.case study

    International Nuclear Information System (INIS)

    El-Aseer, A.; Dawood, E.; Ben Ayad, S.; Alwerfalli, M.

    2015-01-01

    The usefulness of implementing a radioactive tracer techniques subjected to varied risk factors. Thus, the setup procedure for the application experimental techniques of radioactive tracer must be evaluated prior the decision action steps. One way of doing this, is to use Bay's theorem techniques. As there is a possibility of classifying the implemented parameters into certain catogries depending on their certainty to effect radioactive tracer technology. In this paper, the radioactive tracer experimental parameters classified accoring to Bayesian theory. Using this theory, one can study the proposed technical systems to determine the probabilities of the effectiveness of any selected parameter among the others. The classification of the applied experimental parameters into suitable or unsuitable in proposed theoretically. Ten parameters used in this experimental data were classified accordingly. The posterior is calculate from the prior and the likelihood previously determined by bayes rule.(author)

  1. Slew-rate dependence of tracer magnetization response in magnetic particle imaging

    Science.gov (United States)

    Shah, Saqlain A.; Ferguson, R. M.; Krishnan, K. M.

    2014-10-01

    Magnetic Particle Imaging (MPI) is a new biomedical imaging technique that produces real-time, high-resolution tomographic images of superparamagnetic iron oxide nanoparticle tracers. Currently, 25 kHz and 20 mT/μ0 excitation fields are common in MPI, but lower field amplitudes may be necessary for patient safety in future designs. Here, we address fundamental questions about MPI tracer magnetization dynamics and predict tracer performance in future scanners that employ new combinations of excitation field amplitude (Ho) and frequency (ω). Using an optimized, monodisperse MPI tracer, we studied how several combinations of drive field frequencies and amplitudes affect the tracer's response, using Magnetic Particle Spectrometry and AC hysteresis, for drive field conditions at 15.5, 26, and 40.2 kHz, with field amplitudes ranging from 7 to 52 mT/μ0. For both fluid and immobilized nanoparticle samples, we determined that magnetic response was dominated by Néel reversal. Furthermore, we observed that the peak slew-rate (ωHo) determined the tracer magnetic response. Smaller amplitudes provided correspondingly smaller field of view, sometimes resulting in excitation of minor hysteresis loops. Changing the drive field conditions but keeping the peak slew-rate constant kept the tracer response almost the same. Higher peak slew-rates led to reduced maximum signal intensity and greater coercivity in the tracer response. Our experimental results were in reasonable agreement with Stoner-Wohlfarth model based theories.

  2. The use of radiotracer techniques to study lubrication and wear in large diesel engines; Emploi des indicateurs radioactifs pour l'etude de la lubrification et de l'usure dans les moteurs diesel de grande puissance; Ispol'zovanie metodov radioaktivnykh indikatorov dlya izucheniya smazki i iznosa bol'shikh dizel'nykh motorov; Aplicacion de los indicadores radiactivos al estudio de la lubricacion y desgaste de los motores diesel de gran potencia

    Energy Technology Data Exchange (ETDEWEB)

    Howes, Jr, J E; Braun, W J; Sunderman, D N [Battelle Memorial Institute, Columbus, OH (United States)

    1962-01-15

    Radiotracer techniques have been applied to the study of lubrication and wear in large diesel engines on a scale not before considered practical, with perfect safety and with unique technological results. Both lubricating-oil consumption and cylinderliner wear have been evaluated as a function of operating conditions on diesel engines in the 1000 HP range. Techniques were developed for tapping 200 gal (US) of lubricating oil with 60 mc of zinc-65 and determining oil consumption by sampling exhaust gas during operation under a variety of conditions. Measurement of the rate of lubeoil consumption could be made in 10 min rather than the 24 to 48 h previously required. Irradiation techniques were developed for neutron activation of the lower cylinder portion of a 48-in long, 8-in diam. cylinder liner. Suitable thermal-neutron shielding allowed production of 300-d manganese-54 which resulted in extending the useful life of the liner for wear studies by a factor of six to eight over that of a comparable liner thermally activated to produce iron-59. The fact that studies with such large quantities of radioactive material can be carried out in standard research facilities in the diesel engine field opens an entirely new area to tracer applications. Selective activation and judicious use of thermalneutron shielding increases the versatility of the tracer technique in localizing measurement to areas of interest, reducing the total quantity of radioactive material required in wear studies of large parts, and facilitating simultaneous wear-measurement on engine parts of identical chemical composition. (author) [French] On s'est servi d'indicateurs radioactifs pour l'etude de la lubrification et de l'usure des moteurs diesel de grande puissance, et cela a une echelle qui jusqu'a present n'etait pas consideree comme pratiquement realisable, avec m e securite parfaite et des resultats technologiques sans precedent. La consommation de l'huile de graissage et l'usure des chemises

  3. Comparison of thermal, salt and dye tracing to estimate shallow flow velocities: Novel triple-tracer approach

    Science.gov (United States)

    Abrantes, João R. C. B.; Moruzzi, Rodrigo B.; Silveira, Alexandre; de Lima, João L. M. P.

    2018-02-01

    The accurate measurement of shallow flow velocities is crucial to understand and model the dynamics of sediment and pollutant transport by overland flow. In this study, a novel triple-tracer approach was used to re-evaluate and compare the traditional and well established dye and salt tracer techniques with the more recent thermal tracer technique in estimating shallow flow velocities. For this purpose a triple tracer (i.e. dyed-salted-heated water) was used. Optical and infrared video cameras and an electrical conductivity sensor were used to detect the tracers in the flow. Leading edge and centroid velocities of the tracers were measured and the correction factors used to determine the actual mean flow velocities from tracer measured velocities were compared and investigated. Experiments were carried out for different flow discharges (32-1813 ml s-1) on smooth acrylic, sand, stones and synthetic grass bed surfaces with 0.8, 4.4 and 13.2% slopes. The results showed that thermal tracers can be used to estimate shallow flow velocities, since the three techniques yielded very similar results without significant differences between them. The main advantages of the thermal tracer were that the movement of the tracer along the measuring section was more easily visible than it was in the real image videos and that it was possible to measure space-averaged flow velocities instead of only one velocity value, with the salt tracer. The correction factors used to determine the actual mean velocity of overland flow varied directly with Reynolds and Froude numbers, flow velocity and slope and inversely with flow depth and bed roughness. In shallow flows, velocity estimation using tracers entails considerable uncertainty and caution must be taken with these measurements, especially in field studies where these variables vary appreciably in space and time.

  4. Scintigraphy of inflammation with nanometer-sixed colloidal tracers

    International Nuclear Information System (INIS)

    De Schrijver, M.

    1989-01-01

    This book describes a novel approach to the scintigraphy of inflammatory processes of the extremities. It presents a method specially developed to bring this diagnostic modality whithin the reach of every nuclear medicine centre without requiring a special infrastructure or extensively trained personnel. The author revieuws the existing nuclear medicine techniques and critically analyses their relative advantages and pitfalls before proceeding to a detailed account of the use of a colloidal tracer for detecting and monitoring inflammation. The author identifies the pathophysiological basis of his concept and gives extensive preclinical data prior to discussing a number of comparative clinical studies with the new technique. Additional benefits are brought by the book's emphasis on the importance of a solid radiopharmacological foundation to the medically used tracers and demonstrates with a few suprising examples how shortcomings at this level may lead to misleading findings in the daily practive of nuclear medicine, even with routinely used radiopharmaceuticals. (author). refs.; figs.; tabs

  5. Iodine 123-antipyrine. A diffusible tracer for brain exploration

    International Nuclear Information System (INIS)

    Dantonel-Mathieu, Evelyne.

    1978-09-01

    Iodine 123-labelled iodoantipyrine is a liposoluble diffusible tracer which crosses the blood-brain barrier intact. Its build-up in brain tissue is proportional to the regional blood flow. Its behavior was studied in undervascularised brain lesions and in cases where research with traditional radioactive tracers (99mTc and its different vectors for example) has proved limited. Because of the great diffusibility of iodoantipyrine a brain parenchyma image is obtained within minutes after its injection, and this by the use of a non-invasive technique and under good gamma-camera exploration conditions. 81 brain explorations including 11 standards have been carried out on subjects averaging 51,2 years old; these examinations took place in three nuclear medicine centres. The 123 I iodoantipyrine used in each nuclear medicine centre is supplied by the CEA. Iodoantipyrine is labelled with a good yield (>98%) checked by chromatography by means of a CEA kit. After intraveinous injection of 4 to 6 mCi iodine-123 iodoantipyrine, a dynamic study (from 0 to 60 seconds) of the tracer passage in the brain tissue may be followed by static images taken in the next minutes according to a standard procedure. The table of results shows the major interest of this tracer for the exploration of vascular accidents with ischemic lesions, especially in the early phase of the accident. The lesion appears as a hypoactive zone and this lack of perfusion lasts for some minutes after the injection [fr

  6. Standardized 15N tracer method for the determination of parameters of the whole-body protein metabolism in clinical practice

    International Nuclear Information System (INIS)

    Junghans, P.; Jung, K.; Matkowitz, R.

    1984-01-01

    A standardized 15 N tracer method is described for the assessment of nitrogen and protein metabolism in healthy and pathological changed organisms. The method represents an isotope technical procedure for the application in clinical research and practice. The clinical preparation of the patient/proband by means of a standardized nutritional regime, the tracer administration (single dose) and the sampling (urine, blood), the 15 N tracer technique (sample chemistry, emissionsspectrometric isotope analysis) and the mathematical evaluation of 15 N tracer data are described. (author)

  7. PC-based hardware and software for tracer measurements

    International Nuclear Information System (INIS)

    Kaemaeraeinen, V.J.; Kall, Leif; Kaeki, Arvo

    1990-01-01

    Cheap, efficient personal computers can be used for both measurement and analysis. The results can be calculated immediately after the measurements are made in order to exploit the real-time measuring capabilities of tracer techniques fully. In the analysis phase the measurement information is visualized using graphical methods. The programs are menu drive to make them easy to use and adaptable for field conditions. The measuring equipment is modular for easy installation and maintenance. (author)

  8. Comparative effects of application of coated and non-coated urea in clayey and sandy paddy soil microcosms examined by the 15N tracer technique. 2. Effects on soil microbial biomass N and microbial 15N immobilization

    International Nuclear Information System (INIS)

    Acquaye, Solomon; Inubushi, Kazuyuki

    2004-01-01

    Nitrogen fertilizer and soil types exert an impact on plant and soil microbial biomass (SMB). A 15 N tracer experiment was conducted to compare the effects of the application of controlled-release coated urea (CRCU) and urea on SMB in gley (clayey) and sandy paddy soils. The fertilizers were applied at the rate of 8 g N m -2 for CRCU as deep-side placement and 10 g N m -2 for urea mixed into soil or applied into floodwater. The soil type and soil layer (surface: few millimeter depth of surface soil to include benthic algae; subsurface: 1 to 20 cm depth), but not the fertilizer type, affected the amount of microbial biomass N (B N ). On an area basis, subsurface soil layers contained about 2-3 times the amount of B N in the surface layers. The seasonal average B N amount i.e. at 1 to 20 cm depth, in the gley soil was 1.67 g N m -2 , compared to 1.20 g N m -2 for the sandy soil. The proportion of B N in total soil N was significantly influenced by the soil type and soil layer, and was higher for the surface layers of both soils and subsurface layer of the sandy soil than for the subsurface layer of gley soil. Soil type, soil layer, and fertilizer type significantly influenced the amount of microbial biomass 15 N (B 15N ). Unlike B N , the amount of B 15N was significantly higher in the surface (11.9-177.3 mg N m -2 ) than in the subsurface soil layers (4.8-83.6 mg N m -2 ), especially with urea application between 60 and 120 DAT (days after transplanting). At 30 DAT, the subsurface layer of the sandy soil showed a higher B 15N (218 mg N m -2 ) amount than the surface layer (133.4 mg N m -2 ). Sandy soil (4.8-218 mg N m -2 ) and urea (6.2-218 mg N m -2 ) induced a larger increase of the amount of B 15 N than the gley soil (6.2-83.6 mg N m -2 ) and CRCU (4.8-40 mg Nm -2 ). Again, the sandy soil, surface soil layers, and urea induced a higher proportion (%) of B 15N in B N than the gley soil, subsurface soil layers, and CRCU, respectively. The soil type affected B N

  9. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J.S.; Johnson, S.E.; Horne, R.N.; Jackson, P. B. [Pet. Eng. Dept., Stanford University; Culver, G.G. [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0001-01-01

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  10. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J S; Johnson, S E; Horne, R N; Jackson, P B [Pet. Eng. Dept., Stanford University; Culver, G G [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0000-12-30

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  11. Use of artificial tracers in hydrology

    International Nuclear Information System (INIS)

    1991-05-01

    The IAEA has convened an Advisory Group Meeting with the following objectives: To define the role of artificial radioactive tracers for water tracing in comparison with other non-radioactive tracers. To evaluate the real needs of artificial radioactive tracers in hydrology. To identify the fields for which artificial radioactive tracers are useful as well as those in which they can be substituted by other tracers. To discuss the strategy to be adopted to overcome the difficulties derived from the restrictions on the use of radioactive tracers in hydrology. The meeting was held at IAEA Headquarters from 19 to 22 March 1990, and was attended by 30 participants from 15 Member States. The conclusions and recommendations are that the use of artificial radioactive tracers should be restricted to cases where other tracers cannot be used or do not provide the same quality of information. Tritium, iodine-131, bromine-82, chromium-51 in the form of Cr-EDTA, technetium-99m obtained from 99 Mo-generators and gold-198 as an adsorbable tracer are, practically, the only radionuclides used for water tracing. The use of other radionuclides for this purpose does not appear to be necessary, possible and/or convenient. Refs, figs and tabs

  12. Quadratic tracer dynamical models tobacco growth

    International Nuclear Information System (INIS)

    Qiang Jiyi; Hua Cuncai; Wang Shaohua

    2011-01-01

    In order to study the non-uniformly transferring process of some tracer dosages, we assume that the absorption of some tracer by tobacco is a quadratic function of the tracer quantity of the tracer in the case of fast absorption, whereas the exclusion of the tracer from tobacco is a linear function of the tracer quantity in the case of slow exclusion, after the tracer is introduced into tobacco once at zero time. A single-compartment quadratic dynamical model of Logistic type is established for the leaves of tobacco. Then, a two-compartment quadratic dynamical model is established for leaves and calms of the tobacco. Qualitative analysis of the models shows that the tracer applied to the leaves of the tobacco is excluded finally; however, the tracer stays at the tobacco for finite time. Two methods are also given for computing the parameters in the models. Finally, the results of the models are verified by the 32 P experiment for the absorption of tobacco. (authors)

  13. Determination of the dispersion coefficient, in rivers through radioactive and fluorescent tracers

    International Nuclear Information System (INIS)

    Almeida Rosso, T.C. de.

    1986-03-01

    The purpose of this work was to determine experimentally the dispersion coefficient in natural streams through the aplication of radioactive and fluorescent tracers. The technique used to obtain the experimental data was the simmultaneous injection of the radioactive tracer Bromim - 82 and the fluorescent ones, Amidorodamine G. extra and Uranine. A comparison among these different tracers is shown as well as the performance of Uranine in a poluented stream in the presence of suspended sediments. The site chosen for the experiments was the Piabanha River, between Pedro do Rio and Areal, located at Rio de Janeiro state, in a nearly 20 Km strech. (Author) [pt

  14. Influence of nutrition on protein synthesis and 15N tracer data in man

    International Nuclear Information System (INIS)

    Faust, H.

    1984-01-01

    Quantitative studies and measurements of parameters of the protein metabolism in vivo require the isotope methodology. Different 15 N tracer methods with special modifications are available which can be used depending on clinical problems. The oral single pulse application of [ 15 N]glycine is equal to other isotope tracer techniques provided that the basic assumptions of the application are fullfilled. The protein metabolism is clearly influenced by the nutritional status whereby the protein synthesis is more sensitive than the breakdown to altered dietary intakes of protein and energy. The importance of standardized experimental conditions is emphasized for studies with 15 N and the interpretation of tracer data. (author)

  15. Mathematical basis for the measurement of absolute and fractional cardiac output with diffusible tracers by compartmental analysis methods

    International Nuclear Information System (INIS)

    Charkes, N.D.

    1984-01-01

    Using compartmental analysis methods, a mathematical basis is given for the measurement of absolute and fractional cardiac output with diffusible tracers. Cardiac output is shown to be the product of the blood volume and the sum of the rate constants of tracer egress from blood, modified by a factor reflecting transcapillary diffusibility, the transfer fraction. The return of tracer to the blood and distant (intracellular) events are shown to play no role in the solution. Fractional cardiac output is the ratio of the rate constant of tracer egress from blood to an organ, divided by the sum of the egress constants from blood. Predominantly extracellular ions such as sodium or bromide are best suited for this technique, although theoretically any diffusible tracer whose compartmental model can be solved may be used. It is shown that fractional cardiac output is independent of the transfer fraction, and therefore can be measured accurately by tracers which are not freely diffusible

  16. Field ionization mass spectrometry (FIMS) applied to tracer studies and isotope dilution analysis

    International Nuclear Information System (INIS)

    Anbar, M.; Heck, H.d'A.; McReynolds, J.H.; St John, G.A.

    1975-01-01

    The nonfragmenting nature of field ionization mass spectrometry makes it a preferred technique for the isotopic analysis of multilabeled organic compounds. The possibility of field ionization of nonvolatile thermolabile materials significantly extends the potential uses of this technique beyond those of conventional ionization methods. Multilabeled tracers may be studied in biological systems with a sensitivity comparable to that of radioactive tracers. Isotope dilution analysis may be performed reliably by this technique down to picogram levels. These techniques will be illustrated by a number of current studies using multilabeled metabolites and drugs. The scope and limitations of the methodology are discussed

  17. un estudio comparativo

    Directory of Open Access Journals (Sweden)

    Federico Varona

    2007-01-01

    Full Text Available La comunicación efectiva es uno de los mayores retos que tienen hoy las organizaciones y empresas tanto a nivel nacional como internacional (global. Este artículo presenta los resultados de la investigación realizada por un equipo internacional de investigadores interesados en descubrir y comparar las conductas comunicativas o estilos de comunicación de los empleados finlandeses y mexicanos cuando interactúan con sus superiores. Para ello presentamos: primero, un breve marco teórico del estudio; segundo, la metodología; tercero, los resultados del análisis estadístico comparativo entre los empleados de Finlandia y México; cuarto, las conclusiones generales y su explicación cultural; y quinto, las implicaciones teóricas y prácticas de este estudio con respecto a las competencias comunicativas necesarias para la comunicación efectiva entre empleados y superiores tanto en organizaciones nacionales como internacionales (globales.

  18. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, S; Brune, D

    1963-07-15

    {sup 137}Cs - sources were absolutely measured by the 'tracer method', with {sup 82}Br as a tracer nuclide and with application of the 4{pi} {beta}-{gamma} coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 {mu}g/ml. The precision of the method for the determination of the {beta}-emission rate was estimated to {+-} 1 %. The results were compared with those of other works.

  19. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  20. Focuss algorithm application in kinetic compartment modeling for PET tracer

    International Nuclear Information System (INIS)

    Huang Xinrui; Bao Shanglian

    2004-01-01

    Molecular imaging is in the process of becoming. Its application mostly depends on the molecular discovery process of imaging probes and drugs, from the mouse to the patient, from research to clinical practice. Positron emission tomography (PET) can non-invasively monitor . pharmacokinetic and functional processes of drugs in intact organisms at tracer concentrations by kinetic modeling. It has been known that for all biological systems, linear or nonlinear, if the system is injected by a tracer in a steady state, the distribution of the tracer follows the kinetics of a linear compartmental system, which has sums of exponential solutions. Based on the general compartmental description of the tracer's fate in vivo, we presented a novel kinetic modeling approach for the quantification of in vivo tracer studies with dynamic positron emission tomography (PET), which can determine a parsimonious model consisting with the measured data. This kinetic modeling technique allows for estimation of parametric images from a voxel based analysis and requires no a priori decision about the tracer's fate in vivo, instead determining the most appropriate model from the information contained within the kinetic data. Choosing a set of exponential functions, convolved with the plasma input function, as basis functions, the time activity curve of a region or a pixel can be written as a linear combination of the basis functions with corresponding coefficients. The number of non-zero coefficients returned corresponds to the model order which is related to the number of tissue compartments. The system macro parameters are simply determined using the focal underdetermined system solver (FOCUSS) algorithm. The FOCUSS algorithm is a nonparametric algorithm for finding localized energy solutions from limited data and is a recursive linear estimation procedure. FOCUSS algorithm usually converges very fast, so demands a few iterations. The effectiveness is verified by simulation and clinical

  1. Nanoparticle tracers in calcium carbonate porous media

    KAUST Repository

    Li, Yan Vivian; Cathles, Lawrence M.; Archer, Lynden A.

    2014-01-01

    the fractures or channels where flow occurs and thus take much less time to travel between two points. In combination with a chemical tracer they can measure the degree of flow concentration. A prerequisite for tracer applications is that the particles

  2. Tracer filamentation at an unstable ocean front

    Science.gov (United States)

    Feng, Yen Chia; Mahadevan, Amala; Thiffeault, Jean-Luc; Yecko, Philip

    2017-11-01

    A front, where two bodies of ocean water with different physical properties meet, can become unstable and lead to a flow with high strain rate and vorticity. Phytoplankton and other oceanic tracers are stirred into filaments by such flow fields, as can often be seen in satellite imagery. The stretching and folding of a tracer by a two-dimensional flow field has been well studied. In the ocean, however, the vertical shear of horizontal velocity is typically two orders of magnitude larger than the horizontal velocity gradient. Theoretical calculations show that vertical shear alters the way in which horizontal strain affects the tracer, resulting in thin, sloping structures in the tracer field. Using a non-hydrostatic ocean model of an unstable ocean front, we simulate tracer filamentation to identify the effect of vertical shear on the deformation of the tracer. In a complementary laboratory experiment, we generate a simple, vertically sheared strain flow and use dye and particle image velocimetry to quantify the filamentary structures in terms of the strain and shear. We identify how vertical shear alters the tracer filaments and infer how the evolution of tracers in the ocean will differ from the idealized two-dimensional paradigm. Support of NSF DMS-1418956 is acknowledged.

  3. Dynamic dual-tracer PET reconstruction.

    Science.gov (United States)

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  4. Tracer diffusion in ternary alloys

    International Nuclear Information System (INIS)

    Tahir-Kheli, R.A.

    1985-07-01

    An intuitive extension of the theory for diffusion in dynamic binary alloys given in the preceding paper is presented. This theory has also received an independent derivation, based on more formal procedures, by Holdsworth and Elliott. We present Monte Carlo estimates for diffusion correlation factors, fsup(A), fsup(B), and fsup(C) and compare them with the theory. The agreement between the theoretical results and the Monte Carlo estimates for the correlation factors of the slow particles, i.e., fsup(C) and fsup(B), is found to be generally good. In contrast, for the correlation factor, fsup(A), referring to the diffusion coefficient of fast particles in the system, the theoretical results are found to be systematically lower by a small but resolvable margin. It is suggested that this is occasioned by the neglect of spatial constraints on the scattering of coupled tracer-background particle field pairs. (author)

  5. Dos estudios de casos

    Directory of Open Access Journals (Sweden)

    Hernán Guillermo Salazar Morales

    1989-04-01

    Full Text Available RESUMEN A continuación se presenta dos casos de estudio en donde se puede apreciar a la forma  como se establecen  las relaciones en una organización y lo que una DECISION  puede llegar a incidir en el desarrollo de las operaciones de una empresa. Decisiones basadas en la intuición, o en corazonadas, frecuentemente conducen en dirección equivocada, ocasionando pérdidas en tiempo, personal y dinero. El proceso de toma de decisiones deben ser TAREAS ESTRUCTURADAS que se sustenten con hechos. Su ejecución debe hacerse secuencialmente y cumplir con cada uno de sus pasos. El diseño de los  casos está orientado para que  sirvan como material de aplicación en la asignatura de  taller de planeación.

  6. DE AGUA. ESTUDIO PRELIMINAR

    Directory of Open Access Journals (Sweden)

    Esther E. Pellizzari

    2015-01-01

    Full Text Available El objetivo del presente estudio fue investigar la resistencia al arsénico en cultivos puros de Pseudomonas aeruginosa , aislada de aguas subterráneas de Presidencia Roque Sáenz Peña, provincia de Chaco y evaluar la posibilidad de su uso para la remoción de este contaminante presente en las aguas subterráneas. Las cepas fueron inmovilizadas en piedra natural y se cu ltivaron en caldo de sales y 1 mgAs/L . Se observó la resistencia al arsénico y la formación de biofilm , logrando la interacción entre la s células, roca y arsénico . L a remoción de arsénico se evaluó durante 3 meses y el porcentaje de eliminación de arsénico al final del experimento fue 60%.

  7. Transuranic and tracer simulant resuspension

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1977-07-01

    Plutonium resuspension results are summarized for experiments conducted at Rocky Flats, onsite on the Hanford reservation, and for winds blowing from offsite onto the Hanford reservation near the Prosser barricade boundary. In each case, plutonium resuspension was shown by increased airborne plutonium concentrations as a function of either wind speed or as compared to fallout levels. All measured airborne concentrations were below maximum permissible concentrations (MPC). Both plutonium and cesium concentrations on airborne soil were normalized by the quantity of airborne soil sampled. Airborne radionuclide concentrations in μCi/g were related to published values for radionuclide concentrations on surface soils. For this ratio of radionuclide concentration per gram on airborne soil divided by that for ground surface soil, there are eight orders of magnitude uncertainty from 10 -4 to 10 4 . Horizontal plutonium fluxes on airborne nonrespirable soils at all three sites were bracketed within the same three to four orders of magnitude from 10 -7 to 10 -3 μCi/(m 2 day) for plutonium-239 and 10 -8 to 10 -5 μCi/(m 2 day) for plutonium-238. These are the entire experimental base for nonrespirable airborne plutonium transport. Airborne respirable plutonium-239 concentrations increased with wind speed for a southeast wind direction coming from offsite near the Hanford reservation Prosser barricade. Airborne plutonium fluxes on nonrespirable particles had isotopic ratios, 240 Pu/ 239+240 Pu, similar to weapons grade plutonium rather than fallout plutonium. Resuspension rates were summarized for controlled inert particle tracer simulant experiments. Wind resuspension rates for tracers increased with wind speed to about the fifth power

  8. Flow visualization in superfluid helium-4 using He2 molecular tracers

    Science.gov (United States)

    Guo, Wei

    Flow visualization in superfluid helium is challenging, yet crucial for attaining a detailed understanding of quantum turbulence. Two problems have impeded progress: finding and introducing suitable tracers that are small yet visible; and unambiguous interpretation of the tracer motion. We show that metastable He2 triplet molecules are outstanding tracers compared with other particles used in helium. These molecular tracers have small size and relatively simple behavior in superfluid helium: they follow the normal fluid motion at above 1 K and will bind to quantized vortex lines below about 0.6 K. A laser-induced fluorescence technique has been developed for imaging the He2 tracers. We will present our recent experimental work on studying the normal-fluid motion by tracking thin lines of He2 tracers created via femtosecond laser-field ionization in helium. We will also discuss a newly launched experiment on visualizing vortex lines in a magnetically levitated superfluid helium drop by imaging the He2 tracers trapped on the vortex cores. This experiment will enable unprecedented insight into the behavior of a rotating superfluid drop and will untangle several key issues in quantum turbulence research. We acknowledge the support from the National Science Foundation under Grant No. DMR-1507386 and the US Department of Energy under Grant No. DE-FG02 96ER40952.

  9. Measurement of the rate of bacterial protein synthesis in rumen. Part of a coordinated programme on tracer techniques in studies on the use of non-protein nitrogen in ruminants

    International Nuclear Information System (INIS)

    Leng, R.A.

    1975-10-01

    A technique has been developed to differentiate between rumen microbial and dietary protein at the duodenum. Mature whethers fitted with rumen, duodenal and ileal cannulas were fed protein poor diets with added urea, casein and formaldehyde treated casein. These contained 0.30, 1.54, 3.26 and 3.26 % N respectively. The isotopes 35 S or 15 N were infused into the rumen to label microbial protein so that microbial protein could be differentiated from dietary protein. By using the 35 S or 15 N system to mark microbes, it was found that 40% of the formaldehyde treated protein is fermented in the rumen and about 10% is lost in the feces. This indicates that approximately 50% of the protected protein was utilized by the sheep

  10. In-situ fracture mapping using geotomography and brine tracers

    International Nuclear Information System (INIS)

    Deadrick, F.J.; Ramirez, A.L.; Lytle, R.J.

    1981-01-01

    The Lawrence Livermore National Laboratory is currently assessing the capabilities of high resolution geophysical methods to characterize geologic sites for the disposal of high level nuclear waste. A successful experiment has recently been performed in which salt water tracers and high frequency electromagnetic waves were utilized to map rock mass fracture zones in-situ. Multiple cross-borehole EM transmissions were used to generate a tomographic image of the fractured rock region between two boreholes. The tomographs obtained correlate well with conventional wireline geophysical logs which can be used to infer the location of fractured zones in the rock mass. This indirect data suggests that the geotomography and brine tracer technique may have merit in mapping fractured zones between boreholes

  11. Radioimmunoassay techniques in cancer medicine

    International Nuclear Information System (INIS)

    Laurence, D.J.R.

    1978-01-01

    The RIA principle is described, and the application of this technique in cancer treatment is discussed. In general, 125 I is used as tracer. The application of RIA in tumour diagnosis is illustrated by various examples. (VJ) [de

  12. Predictive value of tracer studies for 131I treatment in hyperthyroid cats

    International Nuclear Information System (INIS)

    Broome, M.R.; Turrel, J.M.; Hays, M.T.

    1988-01-01

    In 76 cats with hyperthyroidism, peak thyroidal radioiodine ( 131 I) uptakes and effective half-lives were determined after administration of tracer and therapeutic activities of 131 I. In 6 additional hyperthyroid cats, only peak thyroidal uptakes after administration of tracer and therapeutic activities of 131 I were determined. Good correlation was found between peak thyroidal uptakes of tracer and therapeutic 131 I; however, only fair correlation was observed between effective half-lives. In 79% of the cats, the effective half-life for therapeutic 131 I was longer than that for tracer 131 I. After administration of therapeutic activity of 131 I, monoexponential and biphasic decay curves were observed in 51 and 16 cats, respectively. Using therapeutic kinetic data, radiation doses to the thyroid gland were calculated retrospectively on the basis of 2 methods for determining the activity of 131 I administered: (1) actual administration of tracer-compensated activity and (2) hypothetic administration of uniform activity (3 mCi). Because of the good predictive ability of tracer kinetic data for the therapeutic kinetic data, the tracer-compensated radiation doses came significantly (P = 0.008) closer to the therapeutic goal than did the uniform-activity doses. In addition, the use of tracer kinetic information reduced the extent of the tendency for consistently high uniform-activity doses. A manual method for acquiring tracer kinetic data was developed and was an acceptable alternative to computerized techniques. Adoption of this method gives individuals and institutions with limited finances the opportunity to characterize the iodine kinetics in cats before proceeding with administration of therapeutic activities of 131 I

  13. Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

    International Nuclear Information System (INIS)

    Jung, Yoojin; Han, Byunghyun; Mostafid, M. Erfan; Chiu, Pei; Yazdani, Ramin; Imhoff, Paul T.

    2012-01-01

    Highlights: ► Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. ► Measurement errors for tracer gases were 1–3% in landfill gas. ► Background signals from landfill gas result in elevated limits of detection. ► Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF 6 ), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1–3% in landfill gas but 4–5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3–4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.

  14. Combining tracer flux ratio methodology with low-flying aircraft measurements to estimate dairy farm CH4 emissions

    Science.gov (United States)

    Daube, C.; Conley, S.; Faloona, I. C.; Yacovitch, T. I.; Roscioli, J. R.; Morris, M.; Curry, J.; Arndt, C.; Herndon, S. C.

    2017-12-01

    Livestock activity, enteric fermentation of feed and anaerobic digestion of waste, contributes significantly to the methane budget of the United States (EPA, 2016). Studies question the reported magnitude of these methane sources (Miller et. al., 2013), calling for more detailed research of agricultural animals (Hristov, 2014). Tracer flux ratio is an attractive experimental method to bring to this problem because it does not rely on estimates of atmospheric dispersion. Collection of data occurred during one week at two dairy farms in central California (June, 2016). Each farm varied in size, layout, head count, and general operation. The tracer flux ratio method involves releasing ethane on-site with a known flow rate to serve as a tracer gas. Downwind mixed enhancements in ethane (from the tracer) and methane (from the dairy) were measured, and their ratio used to infer the unknown methane emission rate from the farm. An instrumented van drove transects downwind of each farm on public roads while tracer gases were released on-site, employing the tracer flux ratio methodology to assess simultaneous methane and tracer gas plumes. Flying circles around each farm, a small instrumented aircraft made measurements to perform a mass balance evaluation of methane gas. In the course of these two different methane quantification techniques, we were able to validate yet a third method: tracer flux ratio measured via aircraft. Ground-based tracer release rates were applied to the aircraft-observed methane-to-ethane ratios, yielding whole-site methane emission rates. Never before has the tracer flux ratio method been executed with aircraft measurements. Estimates from this new application closely resemble results from the standard ground-based technique to within their respective uncertainties. Incorporating this new dimension to the tracer flux ratio methodology provides additional context for local plume dynamics and validation of both ground and flight-based data.

  15. The use of radioactive and other tracers in oil and gas measurement

    International Nuclear Information System (INIS)

    Edmonds, E.A.

    1985-01-01

    A description and critical discussion of the use of tracer techniques of flowrate measurement in the oil and gas industries. Radioactive tracers are discussed in particular, with emphasis on the practical aspects of their use. Radiotracers suitable for use in industrial environments are described and discussed. The advantages of radiotracers over conventional chemical tracers are reviewed and the logistical problems associated with the use of radioactive materials are considered. The results of measurements conducted using radiotracers on operating plant and on calibration facilities are presented with a discussion of the accuracy of measurement of flowrate which is achievable: potentially, in ideal circumstances, and in practical situations. The modification of tracer techniques of flow measurement to enable residence time distributions to be evaluated and leaks to be located and quantified on operating process plant is illustrated and discussed. The use of specially synthesized radiochemicals for tracing complex petrochemical processes involving chemical reactions and multiproduct streams is described. The use of novel non-radioactive tracers and specialized detection systems is also described, again with practical illustrations of experience in the field. The benefits offered by the use of these tracers and the limitations encountered are discussed. (author)

  16. Tracer concentration curves and residence time analysis in technological flow systems. 2

    International Nuclear Information System (INIS)

    Pippel, W.

    1976-01-01

    Tracer concentration curves measured in flow systems by means of radioactive isotopes are treated as a two dimensional random process. Comparing them with the family distribution functions described in part I, it follows that only in case of ergodic behaviour of the system tracer curves can be considered as age distribution functions. The conception of ergodicity in residence time systems has been explained with the aid of a time function measurable by a special method of radioactive tracer technique and by the mean value of the residence time obtainable from this function. Furthermore, technological consequences in evaluating tracer concentration curves of real flow systems are discussed with respect to supposed ergodic or nonergodic behaviour. These considerations are of special importance for flow systems with temporary fluctuations in structure. (author)

  17. Application of zinc isotope tracer technology in tracing soil heavy metal pollution

    Science.gov (United States)

    Norbu, Namkha; Wang, Shuguang; Xu, Yan; Yang, Jianqiang; Liu, Qiang

    2017-08-01

    Recent years the soil heavy metal pollution has become increasingly serious, especially the zinc pollution. Due to the complexity of this problem, in order to prevent and treat the soil pollution, it's crucial to accurately and quickly find out the pollution sources and control them. With the development of stable isotope tracer technology, it's able to determine the composition of zinc isotope. Based on the theory of zinc isotope tracer technique, and by means of doing some latest domestic and overseas literature research about the zinc isotope multi-receiving cups of inductively coupled plasma mass spectrometer (MC-ICP-MS) testing technology, this paper summarized the latest research results about the pollution tracer of zinc isotope, and according to the deficiencies and existing problems of previous research, made outlooks of zinc isotope fractionation mechanism, repository establishment and tracer multiple solutions.

  18. Tracers vs. trajectories in a coastal region

    Science.gov (United States)

    Engqvist, A.; Döös, K.

    2008-12-01

    Two different methods of estimating the water exchange through a Baltic coastal region have been used, consisting of particle trajectories and passive tracers. Water is traced from and to a small discharge region near the coast. The discharge material in this region is treated as zero dimensional particles or tracers with neutral buoyancy. The real discharge material could be a leakage of radio-nuclides through the sea floor from an underground repository of nuclear waste. Water exchange rates between the discharge region and the model domain are estimated using both forward and backward trajectories as well as passive tracers. The Lagrangian trajectories can account for the time evolution of the water exchange while the tracers give one average age per model grid box. Water exchange times such as residence time, age and transient times have been calculated with trajectories but only the average age (AvA) for tracers. The trajectory calculations provide a more detailed time evolution than the tracers. On the other hand the tracers are integrated "on-line" simultaneously in the sea circulation model with the same time step while the Lagrangian trajectories are integrated "off-line" from the stored model velocities with its inherent temporal resolution, presently one hour. The sub-grid turbulence is parameterised as a Laplacian diffusion for the passive tracers and with an extra stochastic velocity for trajectories. The importance of the parameterised sub-grid turbulence for the trajectories is estimated to give an extra diffusion of the same order as the Laplacian diffusion by comparing the Lagrangian dispersions with and without parameterisation. The results of the different methods are similar but depend on the chosen diffusivity coefficient with a slightly higher correlation between trajectories and tracers when integrated with a lower diffusivity coefficient.

  19. Estimates of matter yield and N-uptake in sorghum grown on saline and non-saline soils manured with dhaincha (sesbania aculeata) plant residues utilizing 15N tracer techniques

    International Nuclear Information System (INIS)

    Kurdali, F.

    2002-11-01

    Pot experiments were conducted to study the effect of manuring with three types of plant residues (roots, shoots or roots plus shoots) of Dhaincha (Sesbania aculeata Pers.) on the yield and N-uptake of Sorghum bicolor grown in saline and non-saline soils. For measuring various sources of N-uptake, two isotopic dilution techniques were utilized by adding to these soils either 15 N-labelled inorganic N-fertilizer (indirect method) or 15 N-labelled sesbania leaves (direct method). For the indirect method, both soils manured with each type of sesbania residue, received four split applications of 15 N-labelled ammonium sulphate. Results indicated that each type of sesbania residue, applied as a green manure, resulted in significant increases in both dry matter yield and N-uptake of sorghum as compared with the un manured control. Moreover, sesbania residues decreased the harmful effect of salinity on plant growth. Percentages of N derived from residues (%Ndfr) in sorghum grown in non saline soil ranged between 3.9 and 33%; whereas, in saline soil, the observed values ranged between 4.9 and 19.8%. N recoveries in sorghum grown in non saline soil were 61, 45 and 37% of the total amount contained in the sesbania root, shoot and root plus shoot; whereas, values in sorghum grown in saline soils were 48, 14,8 and 15.7%, respectively. The beneficial effects of sesbania residues have been attributed not only to the additional N availability to the plants, but also to its effects on the enhancement of soil N uptake. Percentages and amounts of Ndfr calculated using the indirect method were not significantly different from those obtained by the direct method indicating that the indirect method used herein is feasible and simple for measuring N release from organic residues. It is suggested that the use of Sesbania aculeata residues, particularly the shoots, as a green manure, can provide a substantial portion of total N in sorghum. Moreover, the use of sesbania green manure in

  20. Statistically Based Morphodynamic Modeling of Tracer Slowdown

    Science.gov (United States)

    Borhani, S.; Ghasemi, A.; Hill, K. M.; Viparelli, E.

    2017-12-01

    Tracer particles are used to study bedload transport in gravel-bed rivers. One of the advantages associated with using of tracer particles is that they allow for direct measures of the entrainment rates and their size distributions. The main issue in large scale studies with tracer particles is the difference between tracer stone short term and long term behavior. This difference is due to the fact that particles undergo vertical mixing or move to less active locations such as bars or even floodplains. For these reasons the average virtual velocity of tracer particle decreases in time, i.e. the tracer slowdown. In summary, tracer slowdown can have a significant impact on the estimation of bedload transport rate or long term dispersal of contaminated sediment. The vast majority of the morphodynamic models that account for the non-uniformity of the bed material (tracer and not tracer, in this case) are based on a discrete description of the alluvial deposit. The deposit is divided in two different regions; the active layer and the substrate. The active layer is a thin layer in the topmost part of the deposit whose particles can interact with the bed material transport. The substrate is the part of the deposit below the active layer. Due to the discrete representation of the alluvial deposit, active layer models are not able to reproduce tracer slowdown. In this study we try to model the slowdown of tracer particles with the continuous Parker-Paola-Leclair morphodynamic framework. This continuous, i.e. not layer-based, framework is based on a stochastic description of the temporal variation of bed surface elevation, and of the elevation specific particle entrainment and deposition. Particle entrainment rates are computed as a function of the flow and sediment characteristics, while particle deposition is estimated with a step length formulation. Here we present one of the first implementation of the continuum framework at laboratory scale, its validation against

  1. Process Analysis in Chemical Plant by Means of Radioactive Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hirayama, T.; Hamada, K.; Osada, K. [Showa Denko K.K., Tokyo (Japan)

    1967-06-15

    Following the movement of solids and fluids is important in chemical processes to determine mixing efficiency and residence time. Since it is necessary to follow many complex substances such as raw materials, intermediates and reactants in plant investigations, it is often necessary to ascertain whether the behaviour of the radioisotope tracer and the substance to be traced are identical. The most difficult problem is to determine the best method of labelling, a factor which is a substantial key to the success of an experiment. Usually, there are three labelling techniques: radioisotope labelling, pre-.activation of the material and post-activation of the material. This paper deals with practical examples of the double-tracer technique, a combination of conventional radioisotope labelling and post-activation methods by means of activation analysis. In process analysis by means of tracers, a practical measurement method should also be devised and developed for each experiment. Phosphorus-32 and gold (non-radioactive) were used to measure retention time in a carbon-black plant. The radioisotope was pumped into a feed-stock pipe positioned before the reactor and samples were taken from each process of the plant, including the bag filter, mixer and product tank. After sampling from each step of the process, {sup 32}P in a semi-infinite powder sample was measured in situ by beta counting, and the gold was measured by gamma counting after activating the sample in a reactor. The experiment showed that both tracers had the same residence time, which was shorter than expected. Useful data were also obtained from the dispersion pattern of the material flow for future operation controls, including the time required to change from one grade of product to another. Practical tracer techniques to measure mixing characteristics in high-speed gas flows using {sup 85}Kr have been developed. A study of the measurement method was conducted by calculating the differential values of

  2. A study plan for determining recharge rates at the Hanford Site using environmental tracers

    International Nuclear Information System (INIS)

    Murphy, E.M.; Szercsody, J.E.; Phillips, S.J.

    1991-02-01

    This report presents a study plan for estimating recharge at the Hanford Site using environmental tracers. Past operations at the Hanford Site have led to both soil and groundwater contamination, and recharge is one of the primary mechanisms for transporting contaminants through the vadose zone and into the groundwater. An alternative to using fixed lysimeters for determining recharge rates in the vadose zone is to use environmental tracers. Tracers that have been used to study water movement in the vadose zone include total chloride, 36 Cl, 3 H, and 2 H/ 18 O. Atmospheric levels of 36 Cl and 3 H increased during nuclear bomb testing in the Pacific, and the resulting ''bomb pulse'' or peak concentration can be measured in the soil profile. Locally, past operations at the Hanford Site have resulted in the atmospheric release of numerous chemical and isotopic tracers, including nitrate, 129 I, and 99 Tc. Seven study sites on the Hanford Site have been selected, in two primary soil types that are believed to represent the extremes in recharge, the Quincy sand and the Warden silt loam. An additional background study site upwind of the Hanford facilities has been chosen at the Yakima Firing Center. Six tracer techniques (total chloride, 36 Cl, 3 H, nitrate, 129 I, and 99 Tc) will be tested on at least one site in the Quincy sand, one site in the Warden silt loam, and the background site, to determine which combination of tracers works best for a given soil type. In subsequent years, additional sites will be investigated. The use of environmental tracers is perhaps the only cost-effective method for estimating the spatial variability of recharge at a site as large as Hanford. The tracer techniques used at Hanford have wide applicability at other arid sites. 166 refs., 41 figs., 16 tabs

  3. IMAGE Project: Results of Laboratory Tests on Tracers for Supercritical Conditions.

    Science.gov (United States)

    Brandvoll, Øyvind; Opsahl Viig, Sissel; Nardini, Isabella; Muller, Jiri

    2016-04-01

    The use of tracers is a well-established technique for monitoring dynamic behaviour of water and gas through a reservoir. In geothermal reservoirs special challenges are encountered due to high temperatures and pressures. In this work, tracer candidates for monitoring water at supercritical conditions (temperature > 374°C, pressure ca 218 bar), are tested in laboratory experiments. Testing of tracers at supercritical water conditions requires experimental set-ups which tolerate harsh conditions with respect to high temperature and pressure. In addition stringent HES (health, environment and safety) factors have to be taken into consideration when designing and performing the experiments. The setup constructed in this project consists of a pressure vessel, high pressure pump, instrumentation for pressure and temperature control and instrumentation required for accurate sampling of tracers. In order to achieve accurate results, a special focus has been paid to the development of the tracer sampling technique. Perfluorinated cyclic hydrocarbons (PFCs) have been selected as tracer candidates. This group of compounds is today commonly used as gas tracers in oil reservoirs. According to the literature they are stable at temperatures up to 400°C. To start with, five PFCs have been tested for thermal stability in static experiments at 375°C and 108 bar in the experimental setup described above. The tracer candidates will be further tested for several months at the relevant conditions. Preliminary results indicate that some of the PFC compounds show stability after three months. However, in order to arrive at conclusive results, the experiments have to be repeated over a longer period and paying special attention to more accurate sampling procedures.

  4. The accurate particle tracer code

    Science.gov (United States)

    Wang, Yulei; Liu, Jian; Qin, Hong; Yu, Zhi; Yao, Yicun

    2017-11-01

    The Accurate Particle Tracer (APT) code is designed for systematic large-scale applications of geometric algorithms for particle dynamical simulations. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and nonlinear problems. To provide a flexible and convenient I/O interface, the libraries of Lua and Hdf5 are used. Following a three-step procedure, users can efficiently extend the libraries of electromagnetic configurations, external non-electromagnetic forces, particle pushers, and initialization approaches by use of the extendible module. APT has been used in simulations of key physical problems, such as runaway electrons in tokamaks and energetic particles in Van Allen belt. As an important realization, the APT-SW version has been successfully distributed on the world's fastest computer, the Sunway TaihuLight supercomputer, by supporting master-slave architecture of Sunway many-core processors. Based on large-scale simulations of a runaway beam under parameters of the ITER tokamak, it is revealed that the magnetic ripple field can disperse the pitch-angle distribution significantly and improve the confinement of energetic runaway beam on the same time.

  5. Development of Radioisotope Tracer Technology

    International Nuclear Information System (INIS)

    Jung, Sung Hee; Jin, Joon Ha; Kim, Jong Bum; Kim, Jin Seop; Kim, Jae Jo; Park, Soon Chul; Lim, Don Soon; Choi, Byung Jong; Jang, Dong Soon; Kim, Hye Sook

    2007-06-01

    The project is aimed to develop the radiotracer technology for process optimization and trouble-shooting to establish the environmental and industrial application of radiation and radioisotopes. The advanced equipment and software such as high speed data acquisition system, RTD model and high pressure injection tool have developed. Based on the various field application to the refinery/petrochemical industries, the developed technology was transfer to NDT company for commercial service. For the environmental application of radiotracer technology, injector, detector sled, core sampler, RI and GPS data logging system are developed and field tests were implemented successfully at Wolsung and Haeundae beach. Additionally tracer technology were also used for the performance test of the clarifier in a wastewater treatment plant and for the leak detection in reservoirs. From the experience of case studies on radiotracer experiment in waste water treatment facilities, 'The New Excellent Technology' is granted from the ministry of environment. For future technology, preliminary research for industrial gamma transmission and emission tomography which are new technology combined with radioisotope and image reconstruction are carried out

  6. Compartmental modeling and tracer kinetics

    CERN Document Server

    Anderson, David H

    1983-01-01

    This monograph is concerned with mathematical aspects of compartmental an­ alysis. In particular, linear models are closely analyzed since they are fully justifiable as an investigative tool in tracer experiments. The objective of the monograph is to bring the reader up to date on some of the current mathematical prob­ lems of interest in compartmental analysis. This is accomplished by reviewing mathematical developments in the literature, especially over the last 10-15 years, and by presenting some new thoughts and directions for future mathematical research. These notes started as a series of lectures that I gave while visiting with the Division of Applied ~1athematics, Brown University, 1979, and have developed in­ to this collection of articles aimed at the reader with a beginning graduate level background in mathematics. The text can be used as a self-paced reading course. With this in mind, exercises have been appropriately placed throughout the notes. As an aid in reading the material, the e~d of a ...

  7. Studies of Tracer Dispersion and Fluid Flow in Porous Media

    Energy Technology Data Exchange (ETDEWEB)

    Rage, T.

    1996-12-31

    This doctoral thesis explores the connection between the topology of a porous medium and its macroscopic transport properties and is based on computerized simulation. In porous media, both diffusion and convection contribute to the dispersion of a tracer and their combined effect is emphasized. The governing equations are solved numerically, using finite differences and Monte Carlo technique. The influence of finite Reynolds number on the outcome of echo-experiments is discussed. Comparing experiments and simulations it is found that nonlinear inertial forces lead to a visible deformation of a returned tracer at surprisingly small Reynolds numbers. In a study of tracer dispersion and fluid flow in periodic arrays of discs it is demonstrated that the mechanisms of mechanical dispersion in periodic media and in natural (non-periodic) porous media are essentially different. Measurements of the percolation probability distribution of a sandstone sample is presented. Local porosity theory predicts that this simple geometric function of a porous medium is of dominant importance for its macroscopic transport properties. It is demonstrated that many aspects of transport through fractures can be studied by using simple but realistic models and readily available computer resources. An example may be the transport of hydrocarbon fluids from the source rock to a reservoir. 165 refs., 44 figs., 1 table

  8. Tritium as tracer of flow in constructed wetlands

    International Nuclear Information System (INIS)

    Wachniew, P.; Czuprynski, P.; Maloszewski, P.

    2005-01-01

    Constructed wetlands technology is a cost-effective and environmentally friendly method used world-wide to treat waste waters of different origins. The soluble pollutants are transformed and removed mainly through the processes that occur at surfaces of plants, plant debris or filtering media. The efficiency of soluble pollutants removal is thus primarily related to the extent of contact between waste waters and the reactive surfaces. Residence time distributions function (RTD)is basic characteristic of wetland hydraulic properties and can be obtained by combined use of tracer technique and mathematical modelling. Tritium was used as to obtain RTD's of three parallel cells of a sub-surface flow constructed wetland overgrown with Pharagmites australis in Nowa Slupia. Tritium as a part of water molecule, is an ideal tracer of flow in the highly reactive environment of constructed wetlands. Results of the tracer test interpreted by the assumed model (Multi Flow Dispersion Model) of conservative solute transport revealed a complex structure of flow through the wetland. (author)

  9. Five channel data acquisition system for tracer studies

    International Nuclear Information System (INIS)

    Narender Reddy, J.; Dhananjay Reddy, Y.; Dheeraj Reddy, J.

    2001-01-01

    Radioactive tracers are being used by many modern industries for trouble shooting, process control/quality control and optimization in the process plants. A five channel data acquisition system which has five independent scintillation detector based channels for data acquisition has been developed and made available. This system can be used for tracer studies involving Mean residence time, Resident time distribution and other similar parameters involving tracer movement. System developed can acquire data with dwell times ranging from 10 m sec to 100 sec into each channel and has a capacity to acquire data into 10K channels. Each channel electronics, has a 1x1 NaI Scintillation Detector probe, HV, AMP SCA, micro-controller based data acquisition card with independent dot matrix LCD display for visualization. Extensive use of serial bus (I 2 C, microwire) compatible devices has been incorporated in the design. Data acquisition is initiated simultaneously into all the channels. System design permits delayed/prompt data acquisition selectively. Dual counter switching technique has been employed to achieve faster dwell times for data acquisition. (author)

  10. Tracer verification and monitoring of containment systems

    International Nuclear Information System (INIS)

    Lowry, W.; Dunn, S.D.; Williams, C.

    1996-01-01

    In-situ barrier emplacement techniques and materials for the containment of high-risk contaminants in soils are currently being developed by the Department of Energy (DOE). Because of their relatively high cost, the barriers are intended to be used in cases where the risk is too great to remove the contaminants, the contaminants are too difficult to remove with current technologies, or the potential for movement of the contaminants to the water table is so high that immediate action needs to be taken to reduce health risks. Consequently, barriers are primarily intended for use in high-risk sites where few viable alternatives exist to stop the movement of contaminants in the near term. Assessing the integrity of the barrier once it is emplaced, and during its anticipated life, is a very difficult but necessary requirement. Existing surface-based and borehole geophysical techniques do not provide the degree of resolution required to assure the formation of an integral in-situ barrier. Science and Engineering Associates, Inc., (SEA) and Sandia National Laboratories (SNL) are developing a quantitative subsurface barrier assessment system using gaseous tracers. Called SEAtrace trademark, this system integrates an autonomous, multipoint soil vapor sampling and analysis system with a global optimization modeling methodology to pinpoint leak sources and sizes in real time. SEAtrace trademark is applicable to impermeable barrier emplacements above the water table, providing a conservative assessment of barrier integrity after emplacement, as well as a long term integrity monitoring function. The SEAtrace trademark system is being developed under funding by the DOE-EM Subsurface Contaminant Focus Area

  11. Stable isotopes as tracers for radionuclides

    International Nuclear Information System (INIS)

    Giussani, A.; Bartolo, D. de; Cantone, M.C.; Zilker, T.; Greim, H.; Roth, P.; Werner, E.

    2000-01-01

    The assessment of internal dose after incorporation of radionuclides requires as input data the knowledge of the uptake into the systemic circulation, the distribution and retention in selected organs, the excretion pathways. Realistic biokinetic models are needed for reliable estimates, correct interpretation of bioassay measurements, appropriate decision-making in radiological emergencies. For many radionuclides, however, the biokinetic models currently recommended are often generic, with very few specific parameters, due to the lack of experimental human data. The use of stable isotopes as tracers enables to determine important biokinetic parameters such as the fractional uptake, the clearance from the transfer compartment, the excretion patterns under experimentally controlled conditions. The subjects investigated are not exposed to any radiation risk, so this technique enables to obtain biokinetic information also for sensitive groups of the population, such as children or pregnant women, and to determine age- and gender-specific model parameters. Sophisticated analytical method, able to discriminate and quantitate different isotopes of the same element in complex matrices such as biological fluids, have to be purposely developed and optimized. Activation analysis and mass spectrometry are the most proper techniques of choice. Experiments were conducted with molybdenum, tellurium, ruthenium and zirconium. Activation analysis with protons, thermal ionization mass spectrometry and inductively coupled mass spectrometry were employed for the determination of stable isotopes of these elements in blood plasma and urine samples. Several deviations from the predictions of the ICRP models were observed. For example, modifications to the current model for molybdenum have been suggested on the basis of these results. The dose coefficients to the target regions calculated with this proposed model are even of one order of magnitude different than the ICRP estimates

  12. Tracer surface diffusion on UO2

    International Nuclear Information System (INIS)

    Zhou, S.Y.; Olander, D.R.

    1983-06-01

    Surface diffusion on UO 2 was measured by the spreading of U-234 tracer on the surface of a duplex diffusion couple consisting of wafers of depleted and enriched UO 2 joined by a bond of uranium metal

  13. Bulk velocity measurements by video analysis of dye tracer in a macro-rough channel

    International Nuclear Information System (INIS)

    Ghilardi, T; Franca, M J; Schleiss, A J

    2014-01-01

    Steep mountain rivers have hydraulic and morphodynamic characteristics that hinder velocity measurements. The high spatial variability of hydraulic parameters, such as water depth (WD), river width and flow velocity, makes the choice of a representative cross-section to measure the velocity in detail challenging. Additionally, sediment transport and rapidly changing bed morphology exclude the utilization of standard and often intrusive velocity measurement techniques. The limited technical choices are further reduced in the presence of macro-roughness elements, such as large, relatively immobile boulders. Tracer tracking techniques are among the few reliable methods that can be used under these conditions to evaluate the mean flow velocity. However, most tracer tracking techniques calculate bulk flow velocities between two or more fixed cross-sections. In the presence of intense sediment transport resulting in an important temporal variability of the bed morphology, dead water zones may appear in the few selected measurement sections. Thus a technique based on the analysis of an entire channel reach is needed in this study. A dye tracer measurement technique in which a single camcorder visualizes a long flume reach is described and developed. This allows us to overcome the problem of the presence of dead water zones. To validate this video analysis technique, velocity measurements were carried out on a laboratory flume simulating a torrent, with a relatively gentle slope of 1.97% and without sediment transport, using several commonly used velocity measurement instruments. In the absence of boulders, salt injections, WD and ultrasonic velocity profiler measurements were carried out, along with dye injection technique. When boulders were present, dye tracer technique was validated only by comparison with salt tracer. Several video analysis techniques used to infer velocities were developed and compared, showing that dye tracking is a valid technique for bulk velocity

  14. Single well techniques

    International Nuclear Information System (INIS)

    Drost, W.

    1983-01-01

    The single well technique method includes measurement of parameters of groundwater flow in saturated rock. For determination of filtration velocity the dilution of radioactive tracer is measured, for direction logging the collimeter is rotated in the probe linked with the compass. The limiting factor for measurement of high filtration velocities is the occurrence of turbulent flow. The single well technique is used in civil engineering projects, water works and subsurface drainage of liquid waste from disposal sites. The radioactive tracer method for logging the vertical fluid movement in bore-holes is broadly used in groundwater survey and exploitation. (author)

  15. MEXCODE* CASO DE ESTUDIO

    Directory of Open Access Journals (Sweden)

    Gabriel Arturo García Gómez

    2000-01-01

    Full Text Available El caso plantea la reactivación de un proyecto que se presentó en el año 1995 como alternativa para el desarrollo del centro del Valle y mejora de la eficiencia en el manejo del comercio exterior de la Cuenca Pacífica. El proyecto se revivió a raíz de la necesidad de la compañía patrocinadora de mejorar sus flujos de caja proyectados y la reciente autorización para su funcionamiento. El proyecto es el popularmente denominado “Puerto Seco” de la ciudad de Guadalajara de Buga, internamente nombrado Mexcode. Los estudios iniciales estaban encaminados a que el proyecto fuera manejado por el municipio de Buga, sin embargo, posteriormente se vio la necesidad de buscar que pasara a manos de la empresa privada. El municipio, después de analizar las propuestas de varios inversionistas de la región en las cuales se evaluaba la ubicación dentro de la zona de los predios de sus empresas, su área, proximidad a la línea férrea y a la doble calzada Buga-Tuluá (sitio de paso del 80% de la carga de importación y exportación por Buenaventura y evaluar aspectos relativos a su trayectoria empresarial y compromiso con el desarrollo de la región, decidió otorgarle el proyecto al Grupo Empresarial Agri-Supplies S.A.

  16. Estudio del CH interestelar

    Science.gov (United States)

    Olano, C.; Lemarchand, G.; Sanz, A. J.; Bava, J. A.

    El objetivo principal de este proyecto consiste en el estudio de la distribución y abundancia del CH en nubes interestelares a través de la observación de las líneas hiperfinas del CH en 3,3 GHz. El CH es una molécula de amplia distribución en el espacio interestelar y una de las pocas especies que han sido observadas tanto con técnicas de radio como ópticas. Desde el punto de vista tecnológico se ha desarrollado un cabezal de receptor que permitirá la realización de observaciones polarimétricas en la frecuencia de 3,3 GHz, con una temperatura del sistema de 60 K y un ancho de banda de 140 MHz, y que será instalado en el foco primario de la antena parabólica del IAR. El cabezal del receptor es capaz de detectar señales polarizadas, separando las componentes de polarización circular derecha e izquierda. Para tal fin el cabezal consta de dos ramas receptoras que amplificarán la señal y la trasladarán a una frecuencia más baja (frecuencia intermedia), permitiendo de esa forma un mejor transporte de la señal a la sala de control para su posterior procesamiento. El receptor además de tener características polarimétricas, podrá ser usado en el continuo y en la línea, utilizando las ventajas observacionales y de procesamiento de señal que actualmente posee el IAR.

  17. Modelling tracer transport in fractured rock at Stripa

    International Nuclear Information System (INIS)

    Herbert, A.

    1992-01-01

    We present the results of a modelling study, making predictions for tracer transport experiments carried out within the H-zone feature in the Stripa mine. We use a direct fracture network approach to represent the system of interconnected flow-conducting fractures comprising this zone. It is a highly fractured granite, and our fracture-network models include up to 60000 fractures. We have had to develop efficient algorithms to calculate the flow and transport through these networks; these techniques are described and justified. The first stage of modelling addressed two saline injection experiments. The results of these were known to us and so in addition to 'predicting' the results of these experiments, we used them to calibrate a flow model of the experimental site. This model was then used to make true 'blind' predictions for a set of tracer experiments carried out in the natural head-field, caused by an open drift. Where our flow model was good, our predictions were found to be very accurate, explaining the dispersion in the tracer breakthrough in terms of the fracture network geometry. Discrepancies for experiments in less well characterised regions of the H-zone are presented, and we suggest that the errors in these predictions are a consequence of the inaccuracies of the flow-field. We have demonstrated the use of large-scale fracture network modelling. It has proved very successful, and made very accurate predictions of field experiments carried out at the Stripa mine. The measured dispersion of tracers can be accounted for by the geometry of the fracture network flow system. (14 refs.) (au)

  18. Fluorescence characteristics of the fuel tracers triethylamine and trimethylamine for the investigation of fuel distribution in internal combustion engines.

    Science.gov (United States)

    Lind, Susanne; Aßmann, Simon; Zigan, Lars; Will, Stefan

    2016-03-01

    Laser-induced fluorescence based on fuel tracers like amines is a suitable measurement technique for mixing studies in internal combustion (IC) engines. Triethylamine has often been used in gasoline IC engines; however, no detailed fluorescence characterization for excitation at 263 or 266 nm is available. Trimethylamine (TMA) exhibits high potential as a gaseous fuel tracer but little information about TMA fluorescence is currently available. A picosecond laser source combined with a streak camera equipped with a spectrograph was used to determine the spectral fluorescence emission and fluorescence decay time of both tracers. The tracers were investigated at various temperatures and pressures in a calibration cell with nitrogen as bath gas. The results provide an in-depth understanding of the fluorescence characteristics of both tracers and allow assessment of their application to the investigation of fuel distribution in IC engines.

  19. Tracer monitoring of enhanced oil recovery projects

    Directory of Open Access Journals (Sweden)

    Kleven R.

    2013-05-01

    Full Text Available In enhanced oil recovery (EOR, chemicals are injected into the oil reservoir, either to increase macroscopic sweep efficiency, or to reduce remaining oil saturation in swept zones. Tracers can be used to identify reservoirs that are specifically suited for EOR operations. Injection of a selection of partitioning tracers, combined with frequent sample analysis of produced fluids, provides information suited for estimation of residual oil saturation. Tracers can also be used to evaluate and optimize the application of EOR chemicals in the reservoir. Suitable tracers will follow the EOR chemicals and assist in evaluation of retention, degradation or trapping. In addition to field applications, tracers also have a large potential as a tool to perform mechanistic studies of EOR chemicals in laboratory experiments. By labelling EOR chemicals with radioactive isotopes of elements such as H, C and S, detailed studies of transport mechanisms can be carried out. Co-injection of labelled compounds in dynamic flooding experiments in porous media will give information about retention or separation of the unique compounds constituting the chemical formulation. Separation of such compounds may be detrimental to obtaining the EOR effect expected. The paper gives new information of specific methods, and discusses current status for use of tracers in EOR operations.

  20. Instantaneous axial velocity of a radioactive tracer determined with radioactive particle tracking

    Energy Technology Data Exchange (ETDEWEB)

    Fraguio, Maria Sol; Cassanello, Miryan C., E-mail: miryan@di.fcen.uba.a [Universidad de Buenos Aires (Argentina). Facultad de Ciencias Exactas y Naturales. Programa de Investigacion y Desarrollo de Fuentes Alternativas de Materias Primas y Energia (PINMATE); Cardona, Maria Angelica; Hojman, Daniel, E-mail: cardona@tandar.cnea.gov.a [CONICET, Buenos Aires (Argentina); Somacal, Hector [Comision Nacional de Energia Atomica (CNEA), Buenos Aires (Argentina). Centro Atomico Constituyentes. Dept. de Fisica

    2009-07-01

    Radioactive Particle Tracking (RPT) is a technique that has been successfully used to get features of the liquid and/or the solid motion in multiphase contactors. It is one of the rare techniques able to provide experimental data in dense and strongly turbulent multiphase media. Validation of the technique has always been based on comparing the estimated mean velocity to an imposed mean velocity although the extracted features are frequently related to the instantaneous velocities. The present work pursues the analysis, through calibration experiments, of the ability of RPT to get the actual tracer instantaneous velocities. With this purpose, the motion of a radioactive tracer attached to a moving rod driven by a pneumatic system is reconstructed from the combined response of an array of 10 NaI(Tl) scintillation detectors. Simultaneously, the tracer motion is registered through an encoder able to establish the axial tracer coordinate with high precision and high time resolution. The tracer is a gold particle, activated by neutron bombardment. The rod is moved at different velocities and it travels upwards and downwards close to the column centre. A mini-pilot scale bubble column is used as the test facility. The model liquid is tap water in batch mode and the gas is air, flowing at different gas velocities, spanning the homogeneous and the heterogeneous flow regimes. Time series of the entirety response of all the detectors, while the rod is moving at different imposed velocities within the two phase emulsion, are measured with a sampling period of 0.03 s during about 2 minutes. The instantaneous tracer positions and velocities reconstructed from RPT and the one obtained from the encoder response are compared under different operating conditions and for different tracer velocities. (author)

  1. Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study

    International Nuclear Information System (INIS)

    Rust, T C; Kadrmas, D J

    2006-01-01

    Blood flow and hypoxia are interrelated aspects of physiology that affect cancer treatment and response. Cu-PTSM and Cu-ATSM are related PET tracers for blood flow and hypoxia, and the ability to rapidly image both tracers in a single scan would bring several advantages over conventional single-tracer techniques. Using dynamic imaging with staggered injections, overlapping signals for multiple PET tracers may be recovered utilizing information from kinetics and radioactive decay. In this work, rapid dual-tracer PTSM+ATSM PET was simulated and tested as a function of injection delay, order and relative dose for several copper isotopes, and the results were compared relative to separate single-tracer data. Time-activity curves representing a broad range of tumour blood flow and hypoxia levels were simulated, and parallel dual-tracer compartment modelling was used to recover the signals for each tracer. The main results were tested further using a torso phantom simulation of PET tumour imaging. Using scans as short as 30 minutes, the dual-tracer method provided measures of blood flow and hypoxia similar to single-tracer imaging. The best performance was obtained by injecting PTSM first and using a somewhat higher dose for ATSM. Comparable results for different copper isotopes suggest that tracer kinetics with staggered injections play a more important role than radioactive decay in the signal separation process. Rapid PTSM+ATSM PET has excellent potential for characterizing both tumour blood flow and hypoxia in a single, fast scan, provided that technological hurdles related to algorithm development and routine use can be overcome

  2. Characterization of eco-friendly fluorescent nanoparticle-doped tracers for environmental sensing

    International Nuclear Information System (INIS)

    Tauro, Flavia; Rapiti, Emiliano; Al-Sharab, Jafar F.; Ubertini, Lucio; Grimaldi, Salvatore; Porfiri, Maurizio

    2013-01-01

    Particle tracers are extensively used in quantitative flow visualization and environmental sensing. In this paper, we provide a thorough characterization of the novel eco-friendly fluorescent particle tracers formulated in Tauro et al. (AIP Adv 3(3): 032108, 2013). The tracers are synthesized from natural beeswax and are functionalized by encapsulating nontoxic fluorophore nanoparticles in the beads’ matrix through an inexpensive thermal procedure. Visibility and durability studies are conducted through a wide array of techniques to investigate the tracers’ surface morphological microfeatures, crystal nature and size, chemical composition, fluorophore incorporation into the beeswax matrix, and fluorescence response under severe settings resembling exposure to natural environments. Our findings demonstrate that fluorescent nanoparticles ranging from 1.51 to 3.73 nm are homogeneously distributed in the superficial layer (12 nm) of the tracers. In addition, fluorescence emissions are observed up to 26 days of continuous exposure of the tracers to high energy radiation. To demonstrate the particles’ use in environmental flow sensing, a set of proof of concept outdoor tests are conducted, in which image analysis tools are utilized for detecting the fluorescent tracers. Experimental results suggest that fluorescent microparticles deployed in high flow-rate flows (2 m/s) and under direct sunlight can be sensed through commercially available cameras (frame rate set to 30 Hz)

  3. Partitioning tracers for measuring residual NAPL: Field-scale test results

    International Nuclear Information System (INIS)

    Annable, M.D.; Rao, P.S.C.; Hatfield, K.; Graham, W.D.; Wood, A.L.; Enfield, C.G.

    1998-01-01

    The difficult task of locating and quantifying nonaqueous phase liquids (NAPLs) present in the vadose and saturated zones has prompted the development of innovative, nondestructive characterization techniques. The use of the interwell partitioning tracer's (IWPT) test, in which tracers that partition into the NAPL phase are displaced through the aquifer, is an attractive alternative to traditional coring and analysis. The first field test of IWPT was conducted in a hydraulically isolated test cell to quantify the total amount of a complex NAPL (a mixture of JP-4 jet fuel and chlorinated solvents) trapped within a 1.5-m smear zone in a shallow, unconfined sand and gravel aquifer at Hill Air Force Base (AFB), Utah. Tracer breakthrough curves (BTCs) were measured in three extraction wells (EWs) following a tracer pulse introduction through four injection wells (IWs). The measured retardation of the partitioning tracer (2,2-dimethyl-3-pentanol) relative to the nonreactive tracer (bromide) was used to quantify the NAPL present. The EW data were used to estimate an average NAPL saturation of 4.6--5.4% within the test cell. NAPL saturations estimated by using measured concentrations in soil cores of two significant compounds present in the NAPL were 3.0 and 4.6%

  4. Iron fixation in Egyptian soils using tracer technique

    International Nuclear Information System (INIS)

    Massoud, M.A.; Abd-El-Sabour, M.F.; Omar, M.A.

    1983-01-01

    An experiment was carried out in order to investigate the Fe-fixation in Egyptian soils. Different forms of iron were used for the study, i.e., inorganic form, Fe 2 (So 4 ) 3 and chelated forms, i.e., Fe-EDDHA and Fe-DTPA. The forms were labelled with 59Fe. Data showed that the percent fixed Fe values corresponding to Fe 2 (So 4 ) 3 , Fe-EDDHA and Fe-DTPA were 90, 55, 28 respectively. In addition, the absorbed Fe percentage values were 3, 10.7, 24.3 for the three Fe forms respectively. Also the Fe-soluble percentages values were 5.4, 31.6 and 48.1 respectively. The results indicate the effect of Fe fixed. Also it indicates that the soil application of inorganic salt to supply soluble iron to plants seems unpromising due to the high capacity of investigated soils to retain Fe

  5. Iron fixation in Egyptian soils using tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Massoud, M.A.; Abd-El-Sabour, M.F. (Faculty of Agriculture, Al-Azhar Univ. (Egypt)); Omar, M.A. (Ain Shams Univ., Cairo (Egypt). Faculty of Agriculture)

    1983-01-01

    An experiment was carried out in order to investigate the Fe-fixation in Egyptian soils. Different forms of iron were used for the study, i.e., inorganic form, Fe/sub 2/(So/sub 4/)/sub 3/ and chelated forms, i.e., Fe-EDDHA and Fe-DTPA. The forms were labelled with 59Fe. Data showed that the percent fixed Fe values corresponding to Fe/sub 2/(So/sub 4/)/sub 3/, Fe-EDDHA and Fe-DTPA were 90, 55, 28 respectively. In addition, the absorbed Fe percentage values were 3, 10.7, 24.3 for the three Fe forms respectively. Also the Fe-soluble percentages values were 5.4, 31.6 and 48.1 respectively. The results indicate the effect of Fe fixed. Also it indicates that the soil application of inorganic salt to supply soluble iron to plants seems unpromising due to the high capacity of investigated soils to retain Fe.

  6. studies on iron availability in Egyptian soils using tracer technique

    International Nuclear Information System (INIS)

    Gad allah, A.M.A.

    1984-01-01

    four experiments were conducted to study the available fe in some egyptian soils, representing alluvial,, calcareous, and sandy soils, including the following:1) estimation of soil available iron using different chemical methods as well as E-value and evaluated against biological method. 2) differentiation of iron as Fe 2+ and Fe 2+ in some selected egyptian soils by using the modified method (charlot,1966). 3) determination of total Fe in soil using neutron activation analysis. 4) the relative importance of Fe-diffusion in egyptian soils under different treatments

  7. Chemical reaction on solid surface observed through isotope tracer technique

    International Nuclear Information System (INIS)

    Tanaka, Ken-ichi

    1983-01-01

    In order to know the role of atoms and ions on solid surfaces as the partners participating in elementary processes, the literatures related to the isomerization and hydrogen exchanging reaction of olefines, the hydrogenation of olefines, the metathesis reaction and homologation of olefines based on solid catalysts were reviewed. Various olefines, of which the hydrogen atoms were substituted with deuterium at desired positions, were reacted using various solid catalysts such as ZnO, K 2 CO 3 on C, MoS 2 (single crystal and powder) and molybdenum oxide (with various carriers), and the infra-red spectra of adsorbed olefines on catalysts, the isotope composition of reaction products and the production rate of the reaction products were measured. From the results, the bonding mode of reactant with the atoms and ions on solid surfaces, and the mechanism of the elementary process were considered. The author emphasized that the mechanism of the chemical reaction on solid surfaces and the role of active points or catalysts can be made clear to the considerable extent by combining isotopes suitably. (Yoshitake, I.)

  8. Estenosis traqueal: Estudio preliminar

    Directory of Open Access Journals (Sweden)

    Rafael Pinilla González

    2000-12-01

    Full Text Available Se realizó un estudio retrospectivo y descriptivo con la utilización de los expedientes clínicos de 5 pacientes con estenosis traqueal, mayoritariamente como consecuencia de intubación prolongada, y en el que se tuvo en cuenta aspectos relacionados con el diagnóstico, el tratamiento y las complicaciones. Existió un predominio del sexo femenino y edad media de 44,6 años. La intubación prolongada de origen diverso fue la causa de la estenosis en 4 de los 5 pacientes y en 1 fue posterior a la reparación de lesión traqueal yatrógena. La instalación de la estenosis tuvo lugar entre 8 días y 3 meses. La tomografía lineal en 3 pacientes y en 2 la radiografía simple de tráquea anteroposterior y lateral verificaron el diagnóstico. La endoscopia traqueobronquial preoperatoria fue de utilidad en la caracterización de la estenosis. En todos los pacientes se realizó tratamiento quirúrgico al resecar el área estenótica con posterior anastomosis terminoterminal y fijación del cuello en flexión durante 8 días como promedio. Dos pacientes mostraron granulomas en el nivel de la línea de sutura, los cuales fueron tratados por vacuolización con láser. No se reportó mortalidad en la muestra estudiadaA retrospective and descriptive study was conducted by using the medical histories of 5 patients with tracheal stenosis, mostly as a result of prolongued intubation. Aspects connected with the diagnosis, treatment and complications were taken into account. It was observed a predominance of females and an average age of 44.6. Prolongued intubation of different origin was the cause of stenosis in 4 of the 5 patients, whereas in the other it occurred after the reparation of the tracheal and athrogenous lesion. The installation of stenosis took place between 8 days and 3 months. Lineal tomography in 3 patients and anteroposterior and lateral simple X-ray of the trachea in 2 confirmed the diagnosis. Preoperative tracheobronchial endoscopy was

  9. A single hole tracer test to determine longitudinal dispersion

    International Nuclear Information System (INIS)

    Noy, D.J.; Holmes, D.C.

    1986-03-01

    The paper concerns a single hole tracer test to determine longitudinal dispersion, which is an important parameter in assessing the suitability of a site for radioactive waste disposal. The theory, equipment and procedure for measuring longitudinal dispersion in a single borehole is described. Results are presented for field trials conducted in an aquifer, where the technique produced good results. The measured value of longitudinal dispersion, from a single hole test, relates only to a limited volume of rock immediately adjacent to the borehole. (U.K.)

  10. Design and utilisation of protocols to characterise dynamic PET uptake of two tracers using basis pursuit

    Science.gov (United States)

    Bell, Christopher; Puttick, Simon; Rose, Stephen; Smith, Jye; Thomas, Paul; Dowson, Nicholas

    2017-06-01

    Imaging using more than one biological process using PET could be of great utility, but despite previously proposed approaches to dual-tracer imaging, it is seldom performed. The alternative of performing multiple scans is often infeasible for clinical practice or even in research studies. Dual-tracer PET scanning allows for multiple PET radiotracers to be imaged within the same imaging session. In this paper we describe our approach to utilise the basis pursuit method to aid in the design of dual-tracer PET imaging experiments, and later in separation of the signals. The advantage of this approach is that it does not require a compartment model architecture to be specified or even that both signals are distinguishable in all cases. This means the method for separating dual-tracer signals can be used for many feasible and useful combinations of biology or radiotracer, once an appropriate scanning protocol has been decided upon. Following a demonstration in separating the signals from two consecutively injected radionuclides in a controlled experiment, phantom and list-mode mouse experiments demonstrated the ability to test the feasibility of dual-tracer imaging protocols for multiple injection delays. Increases in variances predicted for kinetic macro-parameters V D and K I in brain and tumoral tissue were obtained when separating the synthetically combined data. These experiments confirmed previous work using other approaches that injections delays of 10-20 min ensured increases in variance were kept minimal for the test tracers used. On this basis, an actual dual-tracer experiment using a 20 min delay was performed using these radio tracers, with the kinetic parameters (V D and K I) extracted for each tracer in agreement with the literature. This study supports previous work that dual-tracer PET imaging can be accomplished provided certain constraints are adhered to. The utilisation of basis pursuit techniques, with its removed need to specify a model

  11. Tracer tests to determine the impact of industrial activities on groundwater

    International Nuclear Information System (INIS)

    Gaspar, R.D.

    1995-01-01

    The drinking water supply from drains of Iasi town is vulnerable to pollution because of the human activities developed in the supply area. To assess the vulnerability, the transfer functions of pollutants were determined using activable tracer and fluorescent dyes. Tracer techniques have been applied in very permeable sediments and in surface waters for the determination of the dynamic parameters of groundwater movements such as flow vectors and dispersion. To determine the residence time distribution of the pollutants, the mathematical models for surface water pollution and an axial dispersion model for the porous medium between the pollution source and catchment were used. Tracer techniques also allowed the determination of water losses under the drain. (author) 7 figs., 1 tab., 12 refs

  12. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    International Nuclear Information System (INIS)

    2004-01-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland

  13. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland.

  14. Copper ion as a new leakage tracer.

    Science.gov (United States)

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  15. Long residence times - bad tracer tests?

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2015-04-01

    Tracer tests conducted at geothermal well doublets or triplets in the Upper Rhine Rift Valley [1] all face, with very few exceptions so far, one common issue: lack of conclusive tracer test results, or tracer signals still undetectable for longer than one or two years after tracer injection. While the reasons for this surely differ from site to site (Riehen, Landau, Insheim, Bruchsal, ...), its effects on how the usefulness of tracer tests is perceived by the non-tracer community are pretty much the same. The 'poor-signal' frustration keeps nourishing two major 'alternative' endeavours : (I) design and execute tracer tests in single-well injection-withdrawal (push-pull), 'instead of' inter-well flow-path tracing configurations; (II) use 'novel' tracer substances instead of the 'old' ones which have 'obviously failed'. Frustration experienced with most inter-well tracer tests in the Upper Rhine Rift Valley has also made them be regarded as 'maybe useful for EGS' ('enhanced', or 'engineered' geothermal systems, whose fluid RTD typically include a major share of values below one year), but 'no longer worthwhile a follow-up sampling' in natural, large-scale hydrothermal reservoirs. We illustrate some of these arguments with the ongoing Bruchsal case [2]. The inter-well tracer test conducted at Bruchsal was (and still is!) aimed at assessing inter-well connectivity, fluid residence times, and characterizing the reservoir structure [3]. Fluid samples taken at the geothermal production well after reaching a fluid turnover of about 700,000 m3 showed tracer concentrations in the range of 10-8 Minj per m3, in the liquid phase of each sample (Minj being the total quantity of tracer injected as a short pulse at the geothermal re-injection well). Tracer signals might actually be higher, owing to tracer amounts co-precipitated and/or adsorbed onto the solid phase whose accumulation in the samples was unavoidable (due to pressure relief and degassing during the very sampling

  16. Flow-rate measurement using radioactive tracers and transit time method

    International Nuclear Information System (INIS)

    Turtiainen, Heikki

    1986-08-01

    The transit time method is a flow measurement method based on tracer techniques. Measurement is done by injecting to the flow a pulse of tracer and measuring its transit time between two detection positions. From the transit time the mean flow velosity and - using the pipe cross section area - the volume flow rate can be calculated. When a radioisotope tracer is used the measurement can be done from outside the pipe and without disturbing the process (excluding the tracer injection). The use of the transit time method has been limited because of difficulties associated with handling and availability of radioactive tracers and lack of equipment suitable for routine use in industrial environments. The purpose of this study was to find out if these difficulties may be overcome by using a portable isotope generator as a tracer source and automating the measurement. In the study a test rig and measuring equipment based on the use of a ''1''3''7Cs/''1''3''7''''mBa isotope generator were constructed. They were used to study the accuracy and error sources of the method and to compare different algorithms to calculate the transit time. The usability of the method and the equipment in industrial environments were studied by carrying out over 20 flow measurements in paper and pulp mills. On the basis of the results of the study, a project for constructing a compact radiatracer flowmeter for industrial use has been started. The application range of this kind of meter is very large. The most obvious applications are in situ calibration of flowmeters, material and energy balance studies, process equipment analyses (e.g. pump efficiency analyses). At the moment tracer techniques are the only methods applicable to these measurements on-line and with sufficient accuracy

  17. Estudios Experimentales 2 Parte: Estudios Cuasi-Experimentales

    OpenAIRE

    Manterola, Carlos; Otzen, Tamara

    2015-01-01

    Los estudios experimentales, se caracterizan por la valoración del efecto de una o más intervenciones, habitualmente de forma comparativa con otra intervención, o un placebo; y el carácter prospectivo, de la recolección de datos y seguimiento. Agrupados bajo esta denominación, existe una diversidad de diseños, entre los que se encuentran los estudios cuasi-experimentales (ECE), que se caracterizan especialmente por la ausencia de asignación aleatoria. El objetivo de este manuscrito, es report...

  18. Characterization of two-phase flow regimes in horizontal tubes using 81mKr tracer experiments.

    Science.gov (United States)

    Oriol, Jean; Leclerc, Jean Pierre; Berne, Philippe; Gousseau, Georges; Jallut, Christian; Tochon, Patrice; Clement, Patrice

    2008-10-01

    The diagnosis of heat exchangers on duty with respect to flow mal-distributions needs the development of non-intrusive inlet-outlet experimental techniques in order to perform an online fault diagnosis. Tracer experiments are an example of such techniques. They can be applied to mono-phase heat exchangers but also to multi-phase ones. In this case, the tracer experiments are more difficult to perform. In order to check for the capabilities of tracer experiments to be used for the flow mal-distribution diagnosis in the case of multi-phase heat exchangers, we present here a preliminary study on the simplest possible system: two-phase flows in a horizontal tube. (81m)Kr is used as gas tracer and properly collimated NaI (TI) crystal scintillators as detectors. The specific shape of the tracer response allows two-phase flow regimes to be characterized. Signal analysis allows the estimation of the gas phase real average velocity and consequently of the liquid phase real average velocity as well as of the volumetric void fraction. These results are compared successfully to those obtained with liquid phase tracer experiments previously presented by Oriol et al. 2007. Characterization of the two-phase flow regimes and liquid dispersion in horizontal and vertical tubes using coloured tracer and no intrusive optical detector. Chem. Eng. Sci. 63(1), 24-34, as well as to those given by correlations from literature.

  19. Characterization of two-phase flow regimes in horizontal tubes using 81mKr tracer experiments

    International Nuclear Information System (INIS)

    Oriol, Jean; Leclerc, Jean Pierre; Berne, Philippe; Gousseau, Georges; Jallut, Christian; Tochon, Patrice; Clement, Patrice

    2008-01-01

    The diagnosis of heat exchangers on duty with respect to flow mal-distributions needs the development of non-intrusive inlet-outlet experimental techniques in order to perform an online fault diagnosis. Tracer experiments are an example of such techniques. They can be applied to mono-phase heat exchangers but also to multi-phase ones. In this case, the tracer experiments are more difficult to perform. In order to check for the capabilities of tracer experiments to be used for the flow mal-distribution diagnosis in the case of multi-phase heat exchangers, we present here a preliminary study on the simplest possible system: two-phase flows in a horizontal tube. 81m Kr is used as gas tracer and properly collimated NaI (TI) crystal scintillators as detectors. The specific shape of the tracer response allows two-phase flow regimes to be characterized. Signal analysis allows the estimation of the gas phase real average velocity and consequently of the liquid phase real average velocity as well as of the volumetric void fraction. These results are compared successfully to those obtained with liquid phase tracer experiments previously presented by Oriol et al. 2007. Characterization of the two-phase flow regimes and liquid dispersion in horizontal and vertical tubes using coloured tracer and no intrusive optical detector. Chem. Eng. Sci. 63(1), 24-34, as well as to those given by correlations from literature

  20. Characterization of two-phase flow regimes in horizontal tubes using {sup 81m}Kr tracer experiments

    Energy Technology Data Exchange (ETDEWEB)

    Oriol, Jean [LPAC, CEA Grenoble, 17, rue des Martyrs, 38054 Grenoble Cedex 9 (France); Leclerc, Jean Pierre [Laboratoire des Sciences du Genie Chimique (LSGC), Nancy-Universite, CNRS, BP 20451, F-54001 Nancy (France)], E-mail: leclerc@ensic.inpl-nancy.fr; Berne, Philippe; Gousseau, Georges [L2T, CEA Grenoble, 17, rue des Martyrs, 38054 Grenoble Cedex 9 (France); Jallut, Christian [Universite de Lyon, Universite Lyon 1, LAGEP, UMR CNRS 5007, ESCPE, 43 Bd du 11 novembre 1918, 69622 Villeurbanne Cedex (France); Tochon, Patrice; Clement, Patrice [GRETh, CEA Grenoble, 17, rue des Martyrs, 38054 Grenoble Cedex 9 (France)

    2008-10-15

    The diagnosis of heat exchangers on duty with respect to flow mal-distributions needs the development of non-intrusive inlet-outlet experimental techniques in order to perform an online fault diagnosis. Tracer experiments are an example of such techniques. They can be applied to mono-phase heat exchangers but also to multi-phase ones. In this case, the tracer experiments are more difficult to perform. In order to check for the capabilities of tracer experiments to be used for the flow mal-distribution diagnosis in the case of multi-phase heat exchangers, we present here a preliminary study on the simplest possible system: two-phase flows in a horizontal tube. {sup 81m}Kr is used as gas tracer and properly collimated NaI (TI) crystal scintillators as detectors. The specific shape of the tracer response allows two-phase flow regimes to be characterized. Signal analysis allows the estimation of the gas phase real average velocity and consequently of the liquid phase real average velocity as well as of the volumetric void fraction. These results are compared successfully to those obtained with liquid phase tracer experiments previously presented by Oriol et al. 2007. Characterization of the two-phase flow regimes and liquid dispersion in horizontal and vertical tubes using coloured tracer and no intrusive optical detector. Chem. Eng. Sci. 63(1), 24-34, as well as to those given by correlations from literature.

  1. Process efficiency in isotope techniques by microelectronics

    International Nuclear Information System (INIS)

    Ziegler, J.; Boelke, L.; Nagli, G.; Schaelicke, W.

    1987-01-01

    The wide application of tracer techniques as a diagnostic tool in nuclear medicine requires the dosage of radioactive tracer solutions in a volume range of 0.5 to 10 ml with a high degree of precision. Two types of computer controlled filling and closing machines for injection bottles are described. Safe handling of radioactive solutions is taken in special consideration. (author)

  2. TRACER - TRACING AND CONTROL OF ENGINEERING REQUIREMENTS

    Science.gov (United States)

    Turner, P. R.

    1994-01-01

    TRACER (Tracing and Control of Engineering Requirements) is a database/word processing system created to document and maintain the order of both requirements and descriptive material associated with an engineering project. A set of hierarchical documents are normally generated for a project whereby the requirements of the higher level documents levy requirements on the same level or lower level documents. Traditionally, the requirements are handled almost entirely by manual paper methods. The problem with a typical paper system, however, is that requirements written and changed continuously in different areas lead to misunderstandings and noncompliance. The purpose of TRACER is to automate the capture, tracing, reviewing, and managing of requirements for an engineering project. The engineering project still requires communications, negotiations, interactions, and iterations among people and organizations, but TRACER promotes succinct and precise identification and treatment of real requirements separate from the descriptive prose in a document. TRACER permits the documentation of an engineering project's requirements and progress in a logical, controllable, traceable manner. TRACER's attributes include the presentation of current requirements and status from any linked computer terminal and the ability to differentiate headers and descriptive material from the requirements. Related requirements can be linked and traced. The program also enables portions of documents to be printed, individual approval and release of requirements, and the tracing of requirements down into the equipment specification. Requirement "links" can be made "pending" and invisible to others until the pending link is made "binding". Individuals affected by linked requirements can be notified of significant changes with acknowledgement of the changes required. An unlimited number of documents can be created for a project and an ASCII import feature permits existing documents to be incorporated

  3. Tracers of air-sea gas exchange

    International Nuclear Information System (INIS)

    Liss, P.S.

    1988-01-01

    The flux of gas across the air-sea interface is determined by the product of the interfacial concentration difference driving the exchange and a rate constant, often termed the transfer velocity. The concentration-difference term is generally obtained by direct measurement, whereas more indirect approaches are required to estimate the transfer velocity and its variation as a function of controlling parameters such as wind and sea state. Radioactive tracers have proved particularly useful in the estimation of air-sea transfer velocities and, recently, stable purposeful tracers have also started to be used. In this paper the use of the following tracers to determine transfer velocities at the sea surface is discussed: natural and bomb-produced 14 C, dissolved oxygen, 222 Rn and sulphur hexafluoride. Other topics covered include the relation between transfer velocity and wind speed as deduced from tracer and wind-tunnel studies, and the discrepancy between transfer velocities determined by using tracers and from eddy correlation measurements in the atmosphere. (author)

  4. A Study of the Dominant Type of Technique (Controlled, Semicontrolled and Free of Two English Teachers from a Languages Teaching Program Estudio acerca del tipo de técnica dominante (controlada, semicontrolada y libre de dos profesores de inglés de un programa en licenciatura en idiomas

    Directory of Open Access Journals (Sweden)

    Francia del Pilar Gavilán Galindo

    2008-12-01

    Full Text Available This article shows the process and emerging results from a study held at a private university in Bogotá, Colombia. It aims at describing and interpreting the dominant kind of language teaching technique: controlled, semicontrolled and free (Brown, 2001 within the context of two first semester English teachers of a languages teaching program. Data collection was based upon class observations, teachers' logs and a semi-structured interview that permitted triangulation of information in order to figure out the central research query. The analysis showed that the controlled technique predominates in both teachers' classes. Thus, this study intends to foster reflection and pedagogical debate regarding its implications for ELT instruction within that university.Este artículo describe el proceso y resultados de un estudio realizado en una universidad privada en Bogotá, Colombia. Busca describir e interpretar el tipo dominante de técnica en la enseñanza de una lengua extranjera: controlada, semicontrolada y libre (Brown, 2001, en el contexto de las clases de inglés de dos profesores de primer semestre de un programa de licenciatura en lenguas extranjeras. La recolección de información se basó en observaciones, fichas de clase y una entrevista semiestructurada, las cuales permitieron triangular los datos con el objetivo de resolver la principal pregunta de investigación. El análisis de la información indicó que la técnica controlada predomina en las clases de ambos profesores. Por tanto, este estudio busca promover la reflexión y debate pedagógico sobre las implicaciones de dicha técnica en la enseñanza del inglés como lengua extranjera en esa institución.

  5. A description of the atmospheric tracer technology used at the J.R.C.-Ispra

    International Nuclear Information System (INIS)

    Gaglione, P.

    1988-01-01

    Atmospheric tracers are a versatile tool that can be used in conjunction with basic meteorological investigations and models to gain a better understanding of the dynamical behaviour of atmospheric pollutants on both the local and regional scales. The tracer activity was initiated at Ispra about ten years ago, with the aim of providing an experimental support to the research activity carried out in the field of air pollution modeling. At the time the area of interest was mainly related to the atmospheric dispersion on a local scale of pollutants released from stacks of power stations, therefore a technique using SF 6 as a tracer was implemented. In the last few years some efforts have been devoted also to the determination of the atmospheric dispersion parameters in the mesoscale and in the regional scale. Due to the limitations in the use of SF 6 over these distances, a new technique utilizing perfluorocarbons (C 7 F 14 and C 8 F 16 ) as tracers has been implemented and positively tested in the field, even though limited until now to a few short range experiments. The purpose of this presentation is to describe the tracer technology developments at the J.R.C.-Ispra including the main results obtained in different field studies

  6. Optimal sample to tracer ratio for isotope dilution mass spectrometry: the polyisotopic case

    International Nuclear Information System (INIS)

    Laszlo, G.; Ridder, P. de; Goldman, A.; Cappis, J.; Bievre, P. de

    1991-01-01

    The Isotope Dilution Mass Spectrometry (IDMS) measurement technique provides a means for determining the unknown amount of various isotopes of an element in a sample solution of known mass. The sample solution is mixed with an auxiliary solution, or tracer, containing a known amount of the same element having the same isotopes but of different relative abundances or isotopic composition and the induced change in the isotopic composition measured by isotope mass spectrometry. The technique involves the measurement of the abundance ratio of each isotope to a (same) reference isotope in the sample solution, in the tracer solution and in the blend of the sample and tracer solution. These isotope ratio measurements, the known element amount in the tracer and the known mass of sample solution are used to calculate the unknown amount of one isotope in the sample solution. Subsequently the unknown amount of element is determined. The purpose of this paper is to examine the optimization of the ratio of the estimated unknown amount of element in the sample solution to the known amount of element in the tracer solution in order to minimize the relative uncertainty in the determination of the unknown amount of element

  7. Study of the oscillations event of the CNLV-U1 with Wavelets techniques; Estudio del evento de oscilaciones de la CNLV-U1 con tecnicas de wavelets

    Energy Technology Data Exchange (ETDEWEB)

    Amador G, R.; Nunez C, A. [CNSNS, Dr. Barragan 779, 03020 Mexico D.F. (Mexico)]. E-mail: ragarcia@cnsns.gob.mx; Prieto G, A.; Espinosa P, G. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    Presently work is described and the techniques are applied of the Fourier Transformation in Short Time, the Continuous Transformation of Wavelets and the Multi resolution Analysis for the analysis of the event of oscillations of power in the Nuclear Power station of Laguna Verde Unit 1 happened in January of 1995. In general, the wavelets techniques allows to carry out studies of the different signals generated by a nuclear plant in the plane Time-frequency, Time-scale as well as the decomposition of the signals. The results obtained study presently demonstrate that the frequency of the event of oscillations in the Nuclear Power station of Laguna Verde Unit 1 are approximately 0.52 Hz for the 3 analysis techniques, besides being observed the evolution of the frequency in function of the time. (Author)

  8. Coefficients of tracer transfer through membranes. Pt. 7

    Energy Technology Data Exchange (ETDEWEB)

    Dorabialska, A; Hawlicka, E; Plonka, A [Politechnika Lodzka (Poland)

    1974-01-01

    The doubled value of the tracer transfer coefficient in the self-diffusion process is equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The fundamental phenomenological relation can be deduced for the coefficients of tracer transfer between two phases of electrolyte solutions spearated by a virtual boundary. Indeed, the doubled value of the tracer mobility in the self-diffusion experiment (no concentration gradient of the traced substance) is equal to the sum of the tracer mobilities in the diffusion (tracer movement along with the concentration gradient of the traced substance) and interfusion experiments (tracer movement against the concentration gradient of the traced substance). Thus the doubled value of the tracer transfer coefficient in the self-diffusion process should be equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The experimental verification of that fundamental relation is presented.

  9. Introduction to nuclear techniques in agronomy and plant biology

    International Nuclear Information System (INIS)

    Vose, P.B.

    1980-01-01

    The subject is covered in chapters, entitled: nature of isotopes and radiation; nuclear reactions; working with radioisotopes; detection systems and instrumentation; radioassay; radioisotopes and tracer principles; stable isotopes as tracers - mainly the use of 15 N; activation analysis for biological samples; x-ray fluorescence spectrography for plants and soils; autoradiography; isotopes in soils studies; isotopic tracers in field experimentation; nuclear techniques in plant science; nuclear techniques for soil water; radiation and other induced mutation in plant breeding. (author)

  10. Tracer applications in oil reservoirs in Brazil

    International Nuclear Information System (INIS)

    Moreira, R.M.; Ferreira Pinto, A.M.

    2004-01-01

    Radiotracer applications in oil reservoirs in Brazil started in 1997 at the request of the State Oil Company (Petrobras) at the Carmoplois oilfield. 1 Ci of HTO was injected in a regular five-spot plot and the results obtained were quite satisfactory. Shortly after this test one other request asked for distinguishing the contribution of different injection wells to a production well. It was then realized that other tracers should be available. As a first choice 35 SCN - has been selected since it could be produced at CDTN. An alternative synthesis path was defined which shortened post-irradiation manipulations. The tracer was tested in core samples and a field injection, simultaneously with HTO, was carried out at the Buracica field; again the HTO performed well but 35 SCN - showed up well ahead. Presently the HTO applications are being done on a routine basis. All in all, four tests were performed (some are still ongoing), and the detection limits for both 3 H and 35 S were optimized by refining the sample preparation stage. Lanthanide complexes used as activable tracers are also an appealing option, however core tests performed so far with La-, Ce- and Eu-EDTA indicated some delay of the tracer, so other complexants such as DOTA are to be tried in further laboratory tests and in a field application. Thus, a deeper understanding of their complexation chemistry and carefully conducted tests must be performed before lanthanide complexes can be qualified as reliable oil reservoir tracers. More recently, Petrobras has been asking for partitioning tracers intended for SOR measurement

  11. Tracer concentration contours in grain lattice and grain boundary diffusion

    International Nuclear Information System (INIS)

    Kim, Y. S.; Olander, D. R.

    1997-01-01

    Grain boundary diffusion plays a significant role in fission gas release, which is one of the crucial processes dominating nuclear fuel performance. Gaseous fission products such as Xe and Kr generated during nuclear fission have to diffuse in the grain lattice and the boundary inside fuel pellets before they reach the open spaces in a fuel rod. These processes can be studied by 'tracer diffusion' techniques, by which grain boundary diffusivity can be estimated and directly used for low burn-up fission gas release analysis. However, only a few models accounting for the both processes are available and mostly handle them numerically due to mathematical complexity. Also the numerical solution has limitations in a practical use. In this paper, an approximate analytical solution in case of stationary grain boundary in a polycrystalline solid is developed for the tracer diffusion techniques. This closed-form solution is compared to available exact and numerical solutions and it turns out that it makes computation not only greatly easier but also more accurate than previous models. It can be applied to theoretical modelings for low burn-up fission gas release phenomena and experimental analyses as well, especially for PIE (post irradiation examination). (author)

  12. The application of mathematical models for the evaluation of radioactive tracer tests carried out in South Africa

    International Nuclear Information System (INIS)

    Snyman, G.C.; Smith, S.W.

    1975-12-01

    The application of mathematical models to evaluate tracer experiments is illustrated by examples of tests done in a variety of industrial plants, using radioactive tracers. Two basic models, the axial mixing model and the perfectly mixed tank model, as well as various applicational techniques, are described. It is concluded that many processes can be simulated to various degrees of accuracy by using the basic models, and that both quantitative and qualitative information can be obtained about the process [af

  13. SIMULASI JARINGAN KOMPUTER MENGGUNAKAN CISCO PACKET TRACER

    Directory of Open Access Journals (Sweden)

    M Mufadhol

    2012-01-01

    Full Text Available Perkembangan jaringan komputer saat ini begitu pesat, monitoring jaringan komputer akan menjadi suatu hal yang sulit dan rumit. Koneksi jaringan komputer merupakan suatu hal yang mendasar dalam suatu jaringan, karena bila koneksi itu bermasalah maka semua jenis aplikasi yang dijalankan melalui jaringan komputer tidak dapat digunakan. Cisco packet tracer dapat digunakan untuk simulasi yang mencerminkan arsitektur dan juga model dari jaringan komputer pada sistem jaringan yang digunakan. Dengan menggunakan aplikasi cisco packet tracer, simulasi mengenai jaringan dapat dimanfaatkan menjadi informasi tentang keadaan koneksi komputer dalam suatu jaringan.

  14. Seasonal Variation in Monthly Average Air Change Rates Using Passive Tracer Gas Measurements

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Bergsøe, Niels Christian; Kolarik, Barbara

    2011-01-01

    in five dwellings in Greater Copenhagen, Denmark. A passive tracer gas technique (Perfluorocarbon) was used to measure ACR in a seven-month period. Considerable differences were observed between the dwellings with monthly ACRs ranging from 0.21 to 1.75 h-1. Only smaller seasonal variations, generally less...... driving forces for natural ventilation is partially compensated by changed occupant behaviour....

  15. Novel targets for positron emission tomography (PET) radiopharmaceutical tracers for visualization of neuroinflammation

    Science.gov (United States)

    Shchepetkin, I.; Shvedova, M.; Anfinogenova, Y.; Litvak, M.; Atochin, D.

    2017-08-01

    Non-invasive molecular imaging techniques can enhance diagnosis of neurological diseases to achieve their successful treatment. Positron emission tomography (PET) imaging can identify activated microglia and provide detailed functional information based on molecular biology. This imaging modality is based on detection of isotope labeled tracers, which emit positrons. The review summarizes the developments of various radiolabeled ligands for PET imaging of neuroinflammation.

  16. Radiological safety methodology in radioactive tracer applications for hydrodynamics and environmental studies

    International Nuclear Information System (INIS)

    Suarez, R.; Badano, A.; Dellepere, A.; Artucio, G.; Bertolotti, A.

    1995-01-01

    The use of radioactive tracer techniques as control sewage disposal contamination in Montevideo Estuarine and Carrasco beach has been studied for the Nuclear Technology National Direction. Hydrodynamic models simulation has been introduced as work methodology. As well as radiological safety and radioactive material applications in the environmental studies has been evaluated mainly in the conclusions and recommendations in this report. maps

  17. Selection of tracers for oil and gas evaluation

    International Nuclear Information System (INIS)

    Bjoernstad, T.

    1991-08-01

    The importance of tracer tests in reservoir descriptions is increasingly acknowledged by reservoir engineers as a method to obtain valuable dynamic information from the reservoir. The report describes the ''state-of-the art'' on tracer technology for interwell investigations. Experiences gained from a number of reported field tracer tests are reviewed, and results from detailed laboratory investigations on the static and dynamic behavior of various tracer molecules are discussed. A critical evaluation of the applicability of the various identified tracers is provided. Present and future trends in the development of tracer technology for reservoir description are sketched. 64 refs., 12 figs., 2 tabs

  18. Industrial applications of radioisotope tracers

    International Nuclear Information System (INIS)

    Easey, J.F.

    1985-01-01

    Radioisotope tracing techniques are powerful tools for analysing the behaviour of large systems and investigating industrially or economically important processes. The results of radioisotope experiments can yield important information, for example, on parameters such as flow rates, mixing phenomena, flow abnormalities and leaks. Some examples of current AAEC research are described, covering studies on hearth drainage in blast furnaces, flow behaviour in waste-water treatment ponds, and sediment transport in marine environments

  19. Skeletal scintigraphy and quantitative tracer studies in metabolic bone disease

    Science.gov (United States)

    Fogelman, Ignac

    Bone scan imaging with the current bone seeking radiopharmaceuticals, the technetium-99m labelled diphosphonates, has dramatically improved our ability to evaluate skeletal pathology. In this thesis, chapter 1 presents a review of the history of bone scanning, summarises present concepts as to the mechanism of uptake of bone seeking agents and briefly illustrates the role of bone scanning in clinical practice. In chapter 2 the applications of bone scan imaging and quantitative tracer techniques derived from the bone scan in the detection of metabolic bone disease are discussed. Since skeletal uptake of Tc-99m diphosphonate depends upon skeletal metabolism one might expect that the bone scan would be of considerable value in the assessment of metabolic bone disease. However in these disorders the whole skeleton is often diffusely involved by the metabolic process and simple visual inspection of the scan image may not reveal the uniformly increased uptake of tracer. Certain patterns of bone scan abnormality have, however, been reported in patients with primary hyperparathyroidism and renal osteo-dystrophy; the present studies extend these observations and introduce the concept of "metabolic features" which are often recognisable in conditions with generalised increased bone turnover. As an aid to systematic recognition of these features on a given bone scan image a semi-quantitative scoring system, the metabolic index, was introduced. The metabolic index allowed differentiation between various groups of patients with metabolic disorders and a control population. In addition, in a bone scan study of patients with acromegaly, it was found that the metabolic index correlated well with disease activity as measured by serum growth hormone levels. The metabolic index was, however, found to be a relatively insensitive means of identifying disease in individual patients. Patients with increased bone turnover will have an absolute increase in skeletal uptake of tracer. As a

  20. Quantitative Visualization of Dynamic Tracer Transportation in the Extracellular Space of Deep Brain Regions Using Tracer-Based Magnetic Resonance Imaging

    Science.gov (United States)

    Hou, Jin; Wang, Wei; Quan, Xianyue; Liang, Wen; Li, Zhiming; Han, Hongbin; Chen, Deji

    2017-01-01

    Background This study assessed an innovative tracer-based magnetic resonance imaging (MRI) system to visualize the dynamic transportation of tracers in regions of deep brain extracellular space (ECS) and to measure transportation ability and ECS structure. Material/Methods Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) was the chosen tracer and was injected into the caudate nucleus and thalamus. Real-time dynamic transportation of Gd-DTPA in ECS was observed and the results were verified by laser scanning confocal microscopy. Using Transwell assay across the blood-brain barrier, a modified diffusion equation was further simplified. Effective diffusion coefficient D* and tortuosity λ were calculated. Immunohistochemical staining and Western blot analysis were used to investigate the extracellular matrix contributing to ECS structure. Results Tracers injected into the caudate nucleus were transported to the ipsilateral frontal and temporal cortices away from the injection points, while both of them injected into the thalamus were only distributed on site. Although the caudate nucleus was closely adjacent to the thalamus, tracer transportation between partitions was not observed. In addition, D* and the λ showed statistically significant differences between partitions. ECS was shown to be a physiologically partitioned system, and its division is characterized by the unique distribution territory and transportation ability of substances located in it. Versican and Tenascin R are possible contributors to the tortuosity of ECS. Conclusions Tracer-based MRI will improve our understanding of the brain microenvironment, improve the techniques for local delivery of drugs, and highlight brain tissue engineering fields in the future. PMID:28866708

  1. Quantitative Visualization of Dynamic Tracer Transportation in the Extracellular Space of Deep Brain Regions Using Tracer-Based Magnetic Resonance Imaging.

    Science.gov (United States)

    Hou, Jin; Wang, Wei; Quan, Xianyue; Liang, Wen; Li, Zhiming; Chen, Deji; Han, Hongbin

    2017-09-03

    BACKGROUND This study assessed an innovative tracer-based magnetic resonance imaging (MRI) system to visualize the dynamic transportation of tracers in regions of deep brain extracellular space (ECS) and to measure transportation ability and ECS structure. MATERIAL AND METHODS Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) was the chosen tracer and was injected into the caudate nucleus and thalamus. Real-time dynamic transportation of Gd-DTPA in ECS was observed and the results were verified by laser scanning confocal microscopy. Using Transwell assay across the blood-brain barrier, a modified diffusion equation was further simplified. Effective diffusion coefficient D* and tortuosity λ were calculated. Immunohistochemical staining and Western blot analysis were used to investigate the extracellular matrix contributing to ECS structure. RESULTS Tracers injected into the caudate nucleus were transported to the ipsilateral frontal and temporal cortices away from the injection points, while both of them injected into the thalamus were only distributed on site. Although the caudate nucleus was closely adjacent to the thalamus, tracer transportation between partitions was not observed. In addition, D* and the λ showed statistically significant differences between partitions. ECS was shown to be a physiologically partitioned system, and its division is characterized by the unique distribution territory and transportation ability of substances located in it. Versican and Tenascin R are possible contributors to the tortuosity of ECS. CONCLUSIONS Tracer-based MRI will improve our understanding of the brain microenvironment, improve the techniques for local delivery of drugs, and highlight brain tissue engineering fields in the future.

  2. Fluxos de nutrientes em larvas de peixes: aplicação de técnicas com marcadores isotópicos e de modelação Nutrient fluxes in fish larvae: use of tracer studies and modelling techniques

    Directory of Open Access Journals (Sweden)

    Luís Conceição

    2007-07-01

    fisiologia da nutrição e crescimento de larvas de peixes.A mechanistic simulation model of fish larval growth should contribute to a better understanding of growth and metabolism of fish larvae. It should also assist in studying the nutritional requirements and developing feeding strategies. A model was developed that simulates growth and biochemical composition in time. The model is driven by feed intake, with absorbed nutrients being used for energy production and biosynthesis, based on the stoicheometry of intermediary metabolism. Model simulations suggest that imbalanced dietary amino acid (AA profiles and dietary lipid excess may lead to suboptimal growth in fish larvae culture. Tracer studies have therefore been used to study AA and lipid metabolism in fish larvae. In addition, modeling techniques have been also used in these studies, to better interpret results obtained. Digestive capacity, as well as utilization of different AA, fatty acids and lipid classes, has been studied using radiolabeled nutrients (normally with 14C using a tube-feeding technique. This method allows quantification of the tracer that is present in faeces, retained in tissues and catabolised. Another method, combining the use of live food in which proteins are labeled with a stable isotope and a spectroscopic/spectrometric technique that allows determination of the isotopic enrichment in individual AA, can be used to estimate ideal dietary indispensable AA profiles. Together these two types of techniques that allow the study of nutrient fluxes have lead to important advances in the understanding of fish larvae nutritional physiology and growth.

  3. Monte Carlo techniques for the study of cancer patients fractionation in head and neck treated with radiotherapy; Tecnicas de Monte Carlo para el estudio del fraccionamiento en pacientes de cancer de cabeza y cuello tratados con radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Carrasco Herrera, M. A.; Jimenez Dominguez, M.; Perucha Ortega, M.; Herrador Cordoba, M.

    2011-07-01

    The dose fractionation than the standard head and neck cancer in some situations involve a significant increase of local control and overall survival. There is clinical evidence of these results in case of hyperfractionated treatments, although the choice of optimal fractionation generally is not obtained from the results of any model, in this study has provided the tumor control probability (TCP) for various subdivisions modified (hypo fractionated and hyperfractionated) using Monte Carlo simulation techniques.

  4. Nuclear medicine and coronary artery disease: evaluation of tracers of myocardial perfusion and vulnerable atherosclerotic plaque

    International Nuclear Information System (INIS)

    Broisat, A.

    2005-04-01

    Coronary artery disease is one of the primary cause of mortality worldwide. Nuclear medicine is the major imaging technique for diagnosis and following of this disease. perfusion: nowadays, major radioactive agents used in clinical practice are myocardial perfusion tracers. The reference tracer is thallium-201. However, 201 Tl presents some drawbacks. 99m Tcn-noet has been proposed for its replacement. This study shows that in contrast with previous studies realized in vitro on cardio myocytes, verapamil, an l-type calcium channel inhibitor, does not inhibit myocardial fixation of 99m Tcn-noet in vivo in dog. This data is in agreement with the hypothesis of a non specific endothelial fixation of this tracer. Moreover, this study shows that as a pure tracer of myocardial perfusion, 99m Tcn-noet can also be used to assess myocardial viability on a model of myocardial chronic infarction in rat. atherosclerosis: disruption of vulnerable atherosclerotic plaques is the main event leading to coronary accidents. The second part of this study concerns the evaluation of new potential tracers of the vulnerable atherosclerotic plaque in an experimental model of rabbit with an inheritable hypercholesterolemia. The four tracers evaluated (b2702(r), b2702-I, b2702-Tc and Tc-raft-b2702) are synthetic peptides comprising the residues 75-84 of hla-b2702, a molecule known to link vcam-1, an adhesion molecule expressed in vulnerable atherosclerotic plaque. The autoradiography studies show that all tracers accumulate within atherosclerotic plaque expressing vcam- and that. i-b2702 shows the best plaque/control fixation ratio. (author)

  5. The use of radioactive tracers in medicine. Part 2. The development of devices for imaging radionuclides

    International Nuclear Information System (INIS)

    Bailey, D.L.

    1996-01-01

    Tracer techniques have been used in medical research for more that two centuries. The history of the measurement of radiotracer in vivo is presented starting with non-imaging, quantitative measurements, and continuing with gamma cameras through to PET scanners. The latest represent the state-of-the-art due to the combination of in-vivo use of tracers with medical tomographic imaging. Its ability to correct accurately for attenuation makes it potentially quantifiable in radioactivity concentration terms and from this follows the ability to determine biological parameters non-invasively. 8 refs., 1 tab. 3 figs

  6. Double tracer autoradiographic method for sequential evaluation of regional cerebral perfusion

    International Nuclear Information System (INIS)

    Matsuda, H.; Tsuji, S.; Oba, H.; Kinuya, K.; Terada, H.; Sumiya, H.; Shiba, K.; Mori, H.; Hisada, K.; Maeda, T.

    1989-01-01

    A new double tracer autoradiographic method for the sequential evaluation of altered regional cerebral perfusion in the same animal is presented. This method is based on the sequential injection of two tracers, 99m Tc-hexamethylpropyleneamine oxime and N-isopropyl-( 125 I)p-iodoamphetamine. This method is validated in the assessment of brovincamine effects on regional cerebral perfusion in an experimental model of chronic brain ischemia in the rat. The drug enhanced perfusion recovery in low-flow areas, selectively in surrounding areas of infarction. The results suggest that this technique is of potential use in the study of neuropharmacological effects applied during the experiment

  7. Nuclear techniques in hydrology

    International Nuclear Information System (INIS)

    Moser, H.

    1976-01-01

    The nuclear techniques used in hydrology are usually tracer techniques based on the use of nuclides either intentionally introduced into, or naturally present in the water. The low concentrations of these nuclides, which must be detected in groundwater and surface water, require special measurement techniques for the concentrations of radioactive or of stable nuclides. The nuclear techniques can be used most fruitfully in conjunction with conventional methods for the solution of problems in the areas of hydrology, hydrogeology and glacier hydrology. Nuclear techniques are used in practice in the areas of prospecting for water, environment protection and engineering hydrogeology. (orig.) [de

  8. Tracer gas diffusion sampling test plan

    International Nuclear Information System (INIS)

    Rohay, V.J.

    1993-01-01

    Efforts are under way to employ active and passive vapor extraction to remove carbon tetrachloride from the soil in the 200 West Area an the Hanford Site as part of the 200 West Area Carbon Tetrachloride Expedited Response Action. In the active approach, a vacuum is applied to a well, which causes soil gas surrounding the well to be drawn up to the surface. The contaminated air is cleaned by passage through a granular activated carbon bed. There are questions concerning the radius of influence associated with application of the vacuum system and related uncertainties about the soil-gas diffusion rates with and without the vacuum system present. To address these questions, a series of tracer gas diffusion sampling tests is proposed in which an inert, nontoxic tracer gas, sulfur hexafluoride (SF 6 ), will be injected into a well, and the rates of SF 6 diffusion through the surrounding soil horizon will be measured by sampling in nearby wells. Tracer gas tests will be conducted at sites very near the active vacuum extraction system and also at sites beyond the radius of influence of the active vacuum system. In the passive vapor extraction approach, barometric pressure fluctuations cause soil gas to be drawn to the surface through the well. At the passive sites, the effects of barometric ''pumping'' due to changes in atmospheric pressure will be investigated. Application of tracer gas testing to both the active and passive vapor extraction methods is described in the wellfield enhancement work plan (Rohay and Cameron 1993)

  9. Use of labeled compounds in tracer experiments

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    The use of radiotracers in research has become common. This chapter looks at some of the underlying assumptions and advantages of labeled compounds: advantages of radiotracers; availability of suitable tracers and labeled compounds; purity of labeled compounds; autoradiolysis; storage of labeled compounds; detection systems for chromatography and electrophoretic methods. 14 refs., 2 figs

  10. Rate tracer studies of heterogeneous catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Happel, J; Kiang, S

    1977-10-01

    An analysis is presented of the extent to which parameters involved in transient tracing of isotopic species in heterogeneous catalysis can be determined by experiments in which tracer concentrations are measured as a function of time. Different treatments for open and closed systems with the over-all reaction at equilibrium or irreversible were developed.

  11. Tracer dispersion in planar multipole flows

    International Nuclear Information System (INIS)

    Koplik, J.; Redner, S.; Hinch, E.J.

    1994-01-01

    We study the motion of passive Brownian tracer particles in steady two-dimensional potential flows between sources and sinks. Our primary focus is understanding the long-time properties of the transit time probability distribution for the tracer to reach the sink p(t) and the influence of the flow geometry on this probability. A variety of illustrative case studies is considered. For radial potential flow in an annular region, competition between convection and diffusion leads to nonuniversal decay of the transit time probability. Dipolar and higher multipole flows are found to exhibit generic features, such as a power-law decay in p(t) with an exponent determined by the multipole moment, an exponential cutoff related to stagnation points, and a ''shoulder'' in p(t) that is related to reflection from the system boundaries. For spatially extended sinks, it is also shown that the spatial distribution of the collected tracer is independent of the overall magnitude of the flow field and that p(t) decays as a power law with a geometry-dependent exponent. Our results may offer the possibility of using tracer measurements to characterize the flow geometry of porous media

  12. Nanoparticle tracers in calcium carbonate porous media

    KAUST Repository

    Li, Yan Vivian

    2014-07-15

    Tracers are perhaps the most direct way of diagnosing subsurface fluid flow pathways for ground water decontamination and for natural gas and oil production. Nanoparticle tracers could be particularly effective because they do not diffuse away from the fractures or channels where flow occurs and thus take much less time to travel between two points. In combination with a chemical tracer they can measure the degree of flow concentration. A prerequisite for tracer applications is that the particles are not retained in the porous media as the result of aggregation or sticking to mineral surfaces. By screening eight nanoparticles (3-100 nm in diameter) for retention when passed through calcium carbonate packed laboratory columns in artificial oil field brine solutions of variable ionic strength we show that the nanoparticles with the least retention are 3 nm in diameter, nearly uncharged, and decorated with highly hydrophilic polymeric ligands. The details of these column experiments and the tri-modal distribution of zeta potential of the calcite sand particles in the brine used in our tests suggests that parts of the calcite surface have positive zeta potential and the retention of negatively charged nanoparticles occurs at these sites. Only neutral nanoparticles are immune to at least some retention. © 2014 Springer Science+Business Media.

  13. Using neural networks to describe tracer correlations

    Directory of Open Access Journals (Sweden)

    D. J. Lary

    2004-01-01

    Full Text Available Neural networks are ideally suited to describe the spatial and temporal dependence of tracer-tracer correlations. The neural network performs well even in regions where the correlations are less compact and normally a family of correlation curves would be required. For example, the CH4-N2O correlation can be well described using a neural network trained with the latitude, pressure, time of year, and methane volume mixing ratio (v.m.r.. In this study a neural network using Quickprop learning and one hidden layer with eight nodes was able to reproduce the CH4-N2O correlation with a correlation coefficient between simulated and training values of 0.9995. Such an accurate representation of tracer-tracer correlations allows more use to be made of long-term datasets to constrain chemical models. Such as the dataset from the Halogen Occultation Experiment (HALOE which has continuously observed CH4  (but not N2O from 1991 till the present. The neural network Fortran code used is available for download.

  14. Fractal tracer distributions in turbulent field theories

    DEFF Research Database (Denmark)

    Hansen, J. Lundbek; Bohr, Tomas

    1998-01-01

    We study the motion of passive tracers in a two-dimensional turbulent velocity field generated by the Kuramoto-Sivashinsky equation. By varying the direction of the velocity-vector with respect to the field-gradient we can continuously vary the two Lyapunov exponents for the particle motion and t...

  15. Pipeline leak detection using volatile tracers

    International Nuclear Information System (INIS)

    Thompson, G.M.; Golding, R.D.

    1993-01-01

    A method of leak detection for underground storage tanks and pipelines adds volatile tracers to the products in the tanks and analyzes the surrounding shallow soil gases for tracer vapors. This method has several advantages: the success of the test is not limited by the size and structural design of the vessels, tanks can be tested at any fill level without taking the tank out of service, the location of a leak along a pipeline is clearly marked by the location of the tracer, and liquid leaks as small as 0.2 liters per hour (lph) can be detected. A limitation is: the backfill material must have some degree of air permeability in the zone above the water table. Several field tests document the success achieved using this method. A tracer leak detection system was installed at Homestead AFB after several other testing methods failed to locate a leak at a valve pit location along approximately 4 kilometers of fuel transfer piping. The leak was detected to the side of the valve pit at a depth of approximately 2.5 meters below the ground surface. Another installation of Edwards AFB involved the collection of 415 soil gas samples along approximately 3,050 meters of 15.25-centimeter fiberglass pipeline. Fourteen separate leaks were detected

  16. Stability Study of Filtering Techniques in Pictures of mini-MIAS Database; Estudio de Estabilidad de Tecnicas de Filtrado en Imagenes de la Base de Datos mini-MIAS

    Energy Technology Data Exchange (ETDEWEB)

    Parcero, E.; Vidal, V.; Verdu, G.; Mayo, P.

    2014-07-01

    The study of filtering techniques applied to medical imaging is particularly important because it can be decisive for an accurate diagnosis. This work aims to study the stability of Fuzzy Peer Group Averaging filter when applied to mammographic images of different nature in relation to the type of tissue abnormality found and diagnosis. The results show that the filter is effective, because obtained a PSNR value of 27 by comparing the filtered image with the original, and a value of 17 by comparing the filtered image with contaminated with noise. Also show that the filter will behave properly regardless of the image characteristics. (Author)

  17. Tracer gas dispersion in ducts-study of a new compact device using arrays of sonic micro jets

    Energy Technology Data Exchange (ETDEWEB)

    Silva, A.R. [Instituto Nacional de Engenharia e Tecnologia Industrial (INETI), Lisboa (Portugal); Afonso, C.F. [Faculdade de Engenharia, Universidade do Porto Departmento de Mecanica e Gestao Industrial, Porto (Portugal)

    2004-07-01

    One of the most feasible ways to measure duct airflows is by tracer gas techniques, especially for complex situations when the duct lengths are short as well as their access, which makes extremely difficult or impossible other methods to be implemented. One problem associated with the implementation of tracer gas technique when the ducts lengths are short is due to the impossibility of achieving complete mixing of the tracer with airflow and its sampling. In this work, the development of a new device for the injection of tracer gas in ducts is discussed as well as a new tracer-sampling device. The developed injection device has a compact tubular shape, with magnetic fixation to be easy to apply in duct walls. An array of sonic micro jets in counter current direction, with the possibility of angular movement according to its main axle ensures a complete mixing of the tracer in very short distances. The tracer-sampling device, with a very effective integration function, feeds the sampling system for analysis. Both devices were tested in a wind tunnel of approximately 21 m total length. The tests distances between injection and integration device considered were: X/Dh = 22; X/Dh = 4; X/Dh 2; and X/Dh = 1. For very short distances of X/Dh = 2 and X/Dh = 1, semi-empirical expressions were needed. A good reproducibility of airflow rate values was obtained. These preliminary tests showed that the practical implementation of tracer gas techniques in HVAC systems for measuring airflow rates with a very short mixing distance is possible with the devices developed. (author)

  18. PIV measurement of a contraction flow using micro-bubble tracer

    International Nuclear Information System (INIS)

    Ishikawa, Masaaki; Irabu, Kunio; Teruya, Isao; Nitta, Munehiro

    2009-01-01

    Recently, a technique using the micro-bubbles is focused. It was applied to many fields such as purification of rivers and lakes, washing the industrial parts, growth of plants and marine products. The characteristics of micro-bubbles are small size, wide surface area, low terminal velocity, and so on. If this micro-bubble is available as tracer of PIV (Particle Image Velocimetry), environment load would become lower because it doesn't need to discard particle. In this paper, we make a micro-bubble generator with Venturi type mechanism. The generated micro-bubbles are applied to a vertical channel flow with contraction. We validate about traceability of the micro-bubble tracer in comparison with the particle tracer.

  19. Deactivation of tracer-flo equipment thru retrieval of its radioactive Krypton-85 gas

    International Nuclear Information System (INIS)

    Domondon, D.B.; Rara, R.B.; Borras, A.M.

    1994-01-01

    Tracer-flo equipment must be cleared of Krypton-85 before these can be transported. The rules and regulations on safe transport of radioactive materials require Kr-85 gas to be transported in an approved container. A new innovative technique/procedure in deactivating tracer-flo equipment i.e., without separation of the Kr-85 from the nitrogen was developed by the authors. The developed procedure was successfully applied in four tracer-flo equipment of three (3) semiconductor firms. In the process, the three firms have saved about US$ 28,000.00 (P 800,000.00) if the deactivation were undertaken by a foreign service company. The Philippine Nuclear Research Institute (PNRI) retrieved about P 382,000.00 worth of Kr-85 that could be used in industrial applications such as leak tracing of buried pipes, etc. (author). 1 ref.; 5 figs

  20. A 82Br tracer study of coastal groundwater movement at Hat Head, NSW

    International Nuclear Information System (INIS)

    Hughes, C.; Stone, D.

    2003-01-01

    At Hat Head, NSW, on the eastern Australian coast, a radioisotope tracer study of groundwater flow in response to tidal forcing was conducted adjacent to a tidal creek. Using radiotracer, 82 Br, groundwater movement was tracked in-situ over 5 days on two occasions encompassing both neap and spring tide conditions. The tracer was injected into one borehole and gamma counts monitored from an adjacent borehole using NaI(Th) detectors. This technique maps the path of the slow moving tracer without sampling and allows the net groundwater movement to be distinguished from short term tidally driven fluxes. During the neap tide period net groundwater movement of 0.1 m/d was observed with horizontal tidal fluctuations in the order of 0.04 m. This contrasts with the tidally dominated spring tide period where net groundwater movement was negligible but tidally driven fluctuations of up to 0.13 m were observed

  1. Count rate balance method of measuring sediment transport of sand beds by radioactive tracers

    International Nuclear Information System (INIS)

    Sauzay, G.

    1968-01-01

    Radioactive tracers are applied to the direct measurement of the sediment transport rate of sand beds. The theoretical measurement formula is derived: the variation of the count rate balance is inverse of that of the transport thickness. Simultaneously the representativeness of the tracer is critically studied. The minimum quantity of tracer which has to be injected in order to obtain a correct statistical definition of count rate given by a low number of grains 'seen' by the detector is then studied. A field experiment was made and has let to study the technological conditions for applying this method: only the treatment of results is new, the experiment itself is carried out with conventional techniques applied with great care. (author) [fr

  2. Feasibility of laser-separation of 36S and its use as an atmospheric tracer

    International Nuclear Information System (INIS)

    Herman, I.P.

    1981-01-01

    This report addresses one of the possible uses of isotopic tracers, produced by laser-assisted iostope separation, in the investigation of pollution problems. Specifically, the use of laser-produced sulfur isotopes to analyze the acid rain situation is considered as it is a most important application of this technique. The proposed use of isotopically-labelled SO 2 , in particular of 36 SO 2 , as a tracer can help elucidate the chemical and transport facets in a unified experiment. Separation of a sufficient quantity of the rare 36 S isotope to perform several of these tracer studies appears to be practical and economical. This overall process is certainly deserving of further investigation

  3. Simultaneous 3D tracking of passive tracers and microtubule bundles in an active gel

    Science.gov (United States)

    Fan, Yi; Breuer, Kenneth S.; Fluids Team

    Kinesin-driven microtubule bundles generate a spontaneous flow in unconfined geometries. They exhibit properties of active matter, including the emergence of collective motion, reduction of apparent viscosity and consumption of local energy. Here we present results from 3D tracking of passive tracers (using Airy rings and 3D scanning) synchronized with 3D measurement of the microtubule bundles motion. This technique is applied to measure viscosity variation and collective flow in a confined geometry with particular attention paid to the self-pumping system recently reported by Wu et al. (2016). Results show that the viscosity in an equilibrium microtubule network is around half that of the isotropic unbundled microtubule solution. Cross-correlations of the active microtubule network and passive tracers define a neighborhood around microtubule bundles in which passive tracers are effectively transported. MRSEC NSF.

  4. Use of radioactive and neutron-activatable tracers to determine effective hydrogeologic parameters

    International Nuclear Information System (INIS)

    Yu, C.; Jester, W.A.; Jarrett, A.R.

    1985-01-01

    The migration of nuclides in a geologic medium is controlled by the hydrogeologic parameters of the medium such as the dispersion coefficient, pore water velocity, retardation factor, degradation rate, mass transfer coefficient, water content, and fraction of dead-end pores. The breakthrough curve (BTC), which is the graphical relationship between the tracer concentration and the elapsed time since introduction, is an integrated picture of the hydrogeologic parameters that produced the BTC. Both radioactive and neutron-activatable tracers have been used to generate BTCs. The BTC of a 92 Br radioactive tracer generated under saturated conditions in a nonhomogeneous (fractured) soil column is shown. From BTCs, the effective hydrogeologic parameters can be identified if appropriate techniques are applied

  5. Halon-1301, a new Groundwater Age Tracer

    Science.gov (United States)

    Beyer, Monique; van der Raaij, Rob; Morgenstern, Uwe; Jackson, Bethanna

    2015-04-01

    Groundwater dating is an important tool to assess groundwater resources in regards to direction and time scale of groundwater flow and recharge and to assess contamination risks and manage remediation. To infer groundwater age information, a combination of different environmental tracers, such as tritium and SF6, are commonly used. However ambiguous age interpretations are often faced, due to a limited set of available tracers and limitations of each tracer method when applied alone. There is a need for additional, complementary groundwater age tracers. We recently discovered that Halon-1301, a water soluble and entirely anthropogenic gaseous substance, may be a promising candidate [Beyer et al, 2014]. Halon-1301 can be determined along with SF6, SF5CF3 and CFC-12 in groundwater using a gas chromatography setup with attached electron capture detector developed by Busenberg and Plummer [2008]. Halon-1301 has not been assessed in groundwater. This study assesses the behaviour of Halon-1301 in water and its suitability as a groundwater age tracer. We determined Halon-1301 in 17 groundwater and various modern (river) waters sites located in 3 different groundwater systems in the Wellington Region, New Zealand. These waters have been previously dated with tritium, CFC-12, CFC-11 and SF6 with mean residence times ranging from 0.5 to over 100 years. The waters range from oxic to anoxic and some show evidence of CFC contamination or degradation. This allows us to assess the different properties affecting the suitability of Halon-1301 as groundwater age tracer, such as its conservativeness in water and local contamination potential. The samples are analysed for Halon-1301 and SF6simultaneously, which allows identification of issues commonly faced when using gaseous tracers such as contamination with modern air during sampling. Overall we found in the assessed groundwater samples Halon-1301 is a feasible new groundwater tracer. No sample indicated significantly elevated

  6. Methods for conduct of atmospheric tracer studies at ANSTO

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G H; Stone, D J.M.; Pascoe, J H [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia). Environment Division

    2000-07-01

    A perfluorocarbon atmospheric tracer system has been developed to investigate atmospheric dispersion processes in the region surrounding the Lucas Heights Science and Technology Centre. This report discusses the tracer release, sampling and analysis methods.

  7. Tracking tracer breakthrough in the hyporheic zone using time‐lapse DC resistivity, Crabby Creek, Pennsylvania

    Science.gov (United States)

    Nyquist, Jonathan E.; Toran, Laura; Fang, Allison C.; Ryan, Robert J.; Rosenberry, Donald O.

    2010-01-01

    Characterization of the hyporheic zone is of critical importance for understanding stream ecology, contaminant transport, and groundwater‐surface water interaction. A salt water tracer test was used to probe the hyporheic zone of a recently re‐engineered portion of Crabby Creek, a stream located near Philadelphia, PA. The tracer solution was tracked through a 13.5 meter segment of the stream using both a network of 25 wells sampled every 5–15 minutes and time‐lapse electrical resistivity tomographs collected every 11 minutes for six hours, with additional tomographs collected every 100 minutes for an additional 16 hours. The comparison of tracer monitoring methods is of keen interest because tracer tests are one of the few techniques available for characterizing this dynamic zone, and logistically it is far easier to collect resistivity tomographs than to install and monitor a dense network of wells. Our results show that resistivity monitoring captured the essential shape of the breakthrough curve and may indicate portions of the stream where the tracer lingered in the hyporheic zone. Time‐lapse resistivity measurements, however, represent time averages over the period required to collect a tomographic data set, and spatial averages over a volume larger than captured by a well sample. Smoothing by the resistivity data inversion algorithm further blurs the resulting tomograph; consequently resistivity monitoring underestimates the degree of fine‐scale heterogeneity in the hyporheic zone.

  8. Laplace transform in tracer kinetic modeling

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, Eliete B., E-mail: eliete@pucrs.br [Instituto do Cerebro (InsCer/FAMAT/PUC-RS), Porto Alegre, RS, (Brazil). Faculdade de Matematica

    2013-07-01

    The main objective this paper is to quantify the pharmacokinetic processes: absorption, distribution and elimination of radiopharmaceutical(tracer), using Laplace transform method. When the drug is administered intravenously absorption is complete and is available in the bloodstream to be distributed throughout the whole body in all tissues and fluids, and to be eliminated. Mathematical modeling seeks to describe the processes of distribution and elimination through compartments, where distinct pools of tracer (spatial location or chemical state) are assigned to different compartments. A compartment model is described by a system of differential equations, where each equation represents the sum of all the transfer rates to and from a specific compartment. In this work a two-tissue irreversible compartment model is used for description of tracer, [{sup 18}F]2-fluor-2deoxy-D-glucose. In order to determine the parameters of the model, it is necessary to have information about the tracer delivery in the form of an input function representing the time-course of tracer concentration in arterial blood or plasma. We estimate the arterial input function in two stages and apply the Levenberg-Marquardt Method to solve nonlinear regressions. The transport of FDG across de arterial blood is very fast in the first ten minutes and then decreases slowly. We use de Heaviside function to represent this situation and this is the main contribution of this study. We apply the Laplace transform and the analytical solution for two-tissue irreversible compartment model is obtained. The only approach is to determinate de arterial input function. (author)

  9. Tracer SWIW tests in propped and un-propped fractures: parameter sensitivity issues, revisited

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2017-04-01

    -scale diffusion; (iii) attempt to determine both advective and non-advective transport parameters from one and the same conservative-tracer signal (relying on 'third-party' knowledge), or from twin signals of a so-called 'dual' tracer pair, e. g.: using tracers with contrasting reactivity and partitioning behavior to determine residual saturation in depleted oilfields (Tomich et al. 1973), or to determine advective parameters (Ghergut et al. 2014); using early-time signals of conservative and sorptive tracers for propped-fracture characterization (Karmakar et al. 2015); using mid-time signals of conservative tracers for a reservoir-borne inflow profiling in multi-frac systems (Ghergut et al. 2016), etc. The poster describes new uses of type-(iii) techniques for the specific purposes of shale-gas reservoir characterization, productivity monitoring, diagnostics and engineering of 're-frac' treatments, based on parameter sensitivity findings from German BMWi research project "TRENDS" (Federal Ministry for Economic Affairs and Energy, FKZ 0325515) and from the EU-H2020 project "FracRisk" (grant no. 640979).

  10. Tracer diffusion in colloidal suspensions under dilute and crowded conditions with hydrodynamic interactions

    DEFF Research Database (Denmark)

    Tomilov, A.; Videcoq, A.; Chartier, T.

    2012-01-01

    We consider tracer diffusion in colloidal suspensions under solid loading conditions, where hydrodynamic interactions play an important role. To this end, we carry out computer simulations based on the hybrid stochastic rotation dynamics-molecular dynamics (SRD-MD) technique. Many details of the ...... that hydrodynamic interactions are correctly included within the SRD-MD technique. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4731661]...

  11. Contribution of radioactive tracers to sediment transport study in fluvial flows

    International Nuclear Information System (INIS)

    Wilson Junior, G.

    1995-01-01

    The uses of radioactive tracers in sediment transport studies are presented in this report to evidence the importance of: Open channel researches, to describe field applications in waterways; Simultaneous utilization of classical methods and radiotracer techniques, in fluvial and estuarine environments; Development of radiotracers techniques applied in dynamic sedimentology. The report illustrated with some experiments carried out in Brazil and France, in open channel and natural flows. (author). 5 refs, 4 figs

  12. New radioactive tracers can help find cause of jaundice

    International Nuclear Information System (INIS)

    Carrard, G.

    1987-01-01

    Radioactive tracers for the investigation of a condition known as persistent jaundice of the newborn, have been designed, prepared and tested at ANSTO. The tracers are chemical compounds of the radioactive elements gallium-67 and indium-111. They given lower radiation doses than the conventional radioactive tracer, iodine-131, used in these studies

  13. PET tracers for somatostatin receptor imaging of neuroendocrine tumors

    DEFF Research Database (Denmark)

    Johnbeck, Camilla Bardram; Knigge, Ulrich; Kjær, Andreas

    2014-01-01

    Neuroendocrine tumors have shown rising incidence mainly due to higher clinical awareness and better diagnostic tools over the last 30 years. Functional imaging of neuroendocrine tumors with PET tracers is an evolving field that is continuously refining the affinity of new tracers in the search...... these PET tracers further....

  14. Tracers discrimination of sediment provenience in rural catchment through EDXRF

    Energy Technology Data Exchange (ETDEWEB)

    Melquiades, Fabio L. [Universidade Estadual do Centro Oeste (UNICENTRO), Guarapuava, PR (Brazil). Dept. de Fisica; Thomaz, Edivaldo L. [Universidade Estadual do Centro Oeste (UNICENTRO), Guarapuava, PR (Brazil). Dept. de Geografia

    2010-07-01

    Full text: Sediment dynamics understanding in a drainage system is fundamental for soil and water conservation at hydro graphic basins. This work aim was to discriminate sediment provenance tracers in rural basin. Sediment samples from different points in the headwater (road, forest, riverbank, river sediment deposit) were collected. Energy Dispersive X-ray Fluorescence (EDXRF) was the analytical technique applied, which was efficient to detect the chemical composition of the sediments. The samples were dried for 48h at 50 deg C, ground and sieved for granulometry 1mm. In natura samples (3 g) were placed in cells covered with mylar film for irradiation. Titanium, Mn, Fe, Cu, Zn, Y and Zr were identified. It was concluded that the elements, when analyzed individually or paired, do not allow a clear environment distinction except for yttrium (Y) that indicates distinct characteristics between the riverbank materials related to the other environments. However, the cluster analysis provided discrimination between the different sources of sediment. Also, it was verified that the recent deposited sediment in the river channel displays greater similarity with the materials of the road than with the riverbank. It is probable that the roads has been the mainly sediment source in the studied headwater. The methodology is innovative for tracer determination in soil and erosion quantification. (author)

  15. Tracers discrimination of sediment provenience in rural catchment through EDXRF

    International Nuclear Information System (INIS)

    Melquiades, Fabio L.; Thomaz, Edivaldo L.

    2010-01-01

    Full text: Sediment dynamics understanding in a drainage system is fundamental for soil and water conservation at hydro graphic basins. This work aim was to discriminate sediment provenance tracers in rural basin. Sediment samples from different points in the headwater (road, forest, riverbank, river sediment deposit) were collected. Energy Dispersive X-ray Fluorescence (EDXRF) was the analytical technique applied, which was efficient to detect the chemical composition of the sediments. The samples were dried for 48h at 50 deg C, ground and sieved for granulometry 1mm. In natura samples (3 g) were placed in cells covered with mylar film for irradiation. Titanium, Mn, Fe, Cu, Zn, Y and Zr were identified. It was concluded that the elements, when analyzed individually or paired, do not allow a clear environment distinction except for yttrium (Y) that indicates distinct characteristics between the riverbank materials related to the other environments. However, the cluster analysis provided discrimination between the different sources of sediment. Also, it was verified that the recent deposited sediment in the river channel displays greater similarity with the materials of the road than with the riverbank. It is probable that the roads has been the mainly sediment source in the studied headwater. The methodology is innovative for tracer determination in soil and erosion quantification. (author)

  16. Optimization of Iron Oxide Tracer Synthesis for Magnetic Particle Imaging

    Directory of Open Access Journals (Sweden)

    Sabina Ziemian

    2018-03-01

    Full Text Available The optimization of iron oxide nanoparticles as tracers for magnetic particle imaging (MPI alongside the development of data acquisition equipment and image reconstruction techniques is crucial for the required improvements in image resolution and sensitivity of MPI scanners. We present a large-scale water-based synthesis of multicore superparamagnetic iron oxide nanoparticles stabilized with dextran (MC-SPIONs. We also demonstrate the preparation of single core superparamagnetic iron oxide nanoparticles in organic media, subsequently coated with a poly(ethylene glycol gallic acid polymer and phase transferred to water (SC-SPIONs. Our aim was to obtain long-term stable particles in aqueous media with high MPI performance. We found that the amplitude of the third harmonic measured by magnetic particle spectroscopy (MPS at 10 mT is 2.3- and 5.8-fold higher than Resovist for the MC-SPIONs and SC-SPIONs, respectively, revealing excellent MPI potential as compared to other reported MPI tracer particle preparations. We show that the reconstructed MPI images of phantoms using optimized multicore and specifically single-core particles are superior to that of commercially available Resovist, which we utilize as a reference standard, as predicted by MPS.

  17. Natural tracer profiles across argillaceous formations

    International Nuclear Information System (INIS)

    Mazurek, Martin; Alt-Epping, Peter; Bath, Adrian; Gimmi, Thomas; Niklaus Waber, H.; Buschaert, Stephane; Canniere, Pierre De; Craen, Mieke De; Gautschi, Andreas; Savoye, Sebastien; Vinsot, Agnes; Wemaere, Isabelle; Wouters, Laurent

    2011-01-01

    Highlights: → Solute transport processes in clay and shale formations at nine sites are examined. → Conservative pore-water tracers (e.g. Cl - , δ 18 O, δ 2 H, He) show regular profiles. → These indicate the dominance of diffusive transport over times of 10 5 -10 6 years. → The contribution of vertical advection to transport is limited or negligible. → Modelled evolution times are in line with independent palaeo-hydrogeological data. - Abstract: Argillaceous formations generally act as aquitards because of their low hydraulic conductivities. This property, together with the large retention capacity of clays for cationic contaminants, has brought argillaceous formations into focus as potential host rocks for the geological disposal of radioactive and other waste. In several countries, programmes are under way to characterise the detailed transport properties of such formations at depth. In this context, the interpretation of profiles of natural tracers in pore waters across the formations can give valuable information about the large-scale and long-term transport behaviour of these formations. Here, tracer-profile data, obtained by various methods of pore-water extraction for nine sites in central Europe, are compiled. Data at each site comprise some or all of the conservative tracers: anions (Cl - , Br - ), water isotopes (δ 18 O, δ 2 H) and noble gases (mainly He). Based on a careful evaluation of the palaeo-hydrogeological evolution at each site, model scenarios are derived for initial and boundary pore-water compositions and an attempt is made to numerically reproduce the observed tracer distributions in a consistent way for all tracers and sites, using transport parameters derived from laboratory or in situ tests. The comprehensive results from this project have been reported in . Here the results for three sites are presented in detail, but the conclusions are based on model interpretations of the entire data set. In essentially all cases, the

  18. Radioiodinated tracers for myocardial imaging

    International Nuclear Information System (INIS)

    Kulkarni, P.V.; Corbett, J.R.

    1990-01-01

    Recent advances in the efficient production of high purity radioiodine (123I) and new efficient radiolabeling techniques have allowed the development of new classes of cardiovascular radiopharmaceuticals. These include 123I-labeled fatty acids to assess myocardial metabolism, 123I-metaiodobenzylguanidine (MIBG) for myocardial neuronal activity, labeled monoclonal antibodies for myocardial necrosis, and labeled lipoproteins for receptor concentration. 123I-labeled fatty acids and MIBG are under clinical investigation with encouraging results. 123I- and 111In-labeled fragments of monoclonal antibodies to myosin have been used for imaging myocardial necrosis in humans. The development of radiotracers for imaging of cholinergic and adrenergic receptors is still in the experimental stage. Recent advances in imaging instrumentation and radiopharmaceuticals have resulted in cardiac imaging applications beyond blood pool ventriculography, perfusion, and infarct-avid imaging. Developments of radioiodine (123I)-labeled agents promise to play an important role in the assessment of myocardial metabolism, neuronal activity, and receptor concentration. The chemistry of iodine is well defined compared with that of 99mTc; therefore, iodine isotopes are well suited for labeling biologically important molecules. Among the iodine isotopes, 123I has nearly ideal nuclear properties for nuclear medical applications with a 13.3-hour half-life (T1/2) and 159 keV gamma emission (83%). Despite the nearly ideal chemical and nuclear properties of 123I, the widespread application of 123I-based radiopharmaceuticals in clinical practice has been limited by high production costs (123I is produced in a cyclotron), relatively limited availability, and the presence of undesirable radionuclidic impurities (124I, T1/2 = 4.2 days; 125I, T1/2 = 60 days; 126I, T1/2 = 13.1 days). 77 references

  19. The Study of Mining Activities and their Influences in the Almaden Region Applying Remote Sensing Techniques; Estudio de la Influencia de las Actividades Mineras de Mercurio en la Comarca de Almaden Aplicando Tecnicas de Teledeteccion

    Energy Technology Data Exchange (ETDEWEB)

    Rico, C; Schmid, T; Millan, R; Gumuzzio, J

    2010-11-17

    This scientific-technical report is a part of an ongoing research work carried out by Celia Rico Fraile in order to obtain the Diploma of Advanced Studies as part of her PhD studies. This work has been developed in collaboration with the Faculty of Science at The Universidad Autonoma de Madrid and the Department of Environment at CIEMAT. The main objective of this work was the characterization and classification of land use in Almaden (Ciudad Real) during cinnabar mineral exploitation and after mining activities ceased in 2002, developing a methodology focused on the integration of remote sensing techniques applying multispectral and hyper spectral satellite data. By means of preprocessing and processing of data from the satellite images as well as data obtained from field campaigns, a spectral library was compiled in order to obtain representative land surfaces within the study area. Monitoring results show that the distribution of areas affected by mining activities is rapidly diminishing in recent years. (Author) 130 refs.

  20. Estudios sobre plantas andinas,- V

    Directory of Open Access Journals (Sweden)

    Cuatrecasas José

    1943-12-01

    Full Text Available Desde hace diez años, he venido interesándome por el conocimiento y clasificación del género Diplostephium, distribuido abundantemente en las zonas frías de los Andes, desde Venezuela al norte de Chile con un enclave en Costa Rica. Las excursiones realizadas en 1932 me permitieron descubrir dos nuevas especies colombianas (1 y el estudio de la colección Isern me dio oportunidad de conocer otras especies ecuatorianas y peruanas (2. A raíz del abundante material recogido en mis excursiones por Colombia desde el año 1938, decidí llevar a cabo el estudio monográfico del género; para ella diversos centros de los Estados Unidos pusieron a mi disposición sus coIecciones: Smithsonian Institution (United States National Herbarium, Field Museum of Natural History de Chicago y New York Botanical Garden, los cuales me remitieron el material para este fin al Instituto de Ciencias Naturales de Bogotá; el trabajo fue iniciado en este centro, pero al trasladarme a la Escuela Superior de Agricultura Tropical de Cali, la dirección del Instituto me permitió llevar para el Valle todos los ejemplares, incluso los del Herbario Nacional Colombiano, y así pude concluir el estudio provisional, en mi nuevo lugar de trabajo.

  1. Portable XRF and PIXE as complementary techniques for the analysis of old books: study of decorated flyleaves and edges; FRX portatil y PIXE como tecnicas complementarias para el analisis de libros antiguos: estudio de guardas y cantos decorados

    Energy Technology Data Exchange (ETDEWEB)

    Torner M, L.; Gonzalez T, C. [Laboratorio de Conservacion, Biblioteca Nacional de Antropologia e Historia, INAH, Paseo dela Reforma y Gandhi s/n Chapultepec Polanco, Mexico DF 11560 (Mexico); Ruvalcaba S, J.L. [Instituto de Fisica, UNAM. A.P. 20-364, Mexico DF 01000 (Mexico)]. e-mail: luciatorner@gmail.com

    2006-07-01

    Traditionally in the study of ancient books, the binding (leather, parchment, cloth) and their decorations have not the same importance than other parts of the book. Most of the times, paper, inks and internal decorations attract entirely the attention for analytical studies. Nevertheless, it must be considered that the binding keep the book safe and it may be exposed D higher deterioration. Moreover, often it is changed and the historical value of this part of the book is lost. his is also the case of binding's decorations. For these reasons, it is clear that the binding of ancient books must be studied as a part of their material essence. In this work, methodology based on t]he combined use of microscopic and elemental analyses was applied in order to study four types of decorations of guards of books (marbled, colored, splashed, dotted). In particular, this study was focused on Colonial and Mexican books from XVIII and XIX centuries from the collection of the Biblioteca Nacional de Antropologia e Historia, lNAH. Twelve books and 62 decoration's colors were analyzed in situ, in the library, using a portable X-ray Fluorescence Spectroscopy system (XRF) for a quick nondestructive pigment identification and to select a reduced number of books for complementary analyses at the laboratory by Particle Induced X-ray Emission Spectroscopy (PIXE). By combining these nondestructive techniques, it was possible to identify most of the pigments used in the decorations and to establish a general pattern of use of colorants and pigments in XVIII and XIX centuries for the guard's decorations. This work represents the first study on this topic. (Author)

  2. {sup 210}Pb as tracer of environmental processes; El {sup 210}Pb como trazador de procesos ambientales

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Orellana, Jordi [Universitat Autonoma de Barcelona (Spain); Sanchez-Cabeza, Joan-Albert [Organismo Internacional de la Energia Atomica, Vienna (Austria); Medio Marino, Laboratorios del [Monaco

    2012-07-01

    {sup 210}Pb is a radionuclide naturally occurring radioactive belonging to the chain of {sup 238}U. Its half-life is T{sub 1/2} = 22.23 {+-} 0.12 yr. There is some discrepancy in the order of 0.1% of this value and, therefore, not significantly affect the results of the chronology, affected by sources of much greater uncertainty. Assuming that {sup 210}Pb can be detected up to about 5 times its half-life, we can expect that {sup 210}Pb can provide useful information for the last 100 years or so, although this depends on the analytical techniques used and the precision of the assay. {sup 210}Pb plays an important role in the study of the environment as it is present in the atmosphere, lithosphere and hydrosphere. This tracer has been used successfully in the study of biogeochemical processes in the oceans, atmospheric deposition and anthropogenic pollution, sedimentary processes and sediment geochronology. [Spanish] El {sup 210}Pb es un radionuclido de origen natural perteneciente a la cadena radiactiva del {sup 238}U. Su periodo de semidesintegracion es de T{sub 1/2} = 22.23 {+-} 0.12 yr. Existen ciertas discrepancias del orden del 0.1% sobre este valor y, por lo tanto, no afectan de forma relevante a los resultados de la cronologia, afectada por fuentes de incertidumbre mucho mayores. Asumiendo que el {sup 210}Pb puede ser detectado hasta unas 5 veces su periodo de semidesintegracion, podemos esperar que el {sup 210}Pb pueda proporcionar informacion util durante los ultimos 100 anos aproximadamente, si bien esto depende de las tecnicas analiticas utilizadas y la precision del ensayo. El {sup 210}Pb juega un papel importante en el estudio del medio ambiente ya que esta presente tanto en la atmosfera, la litosfera y la hidrosfera. Este trazador de procesos ambientales ha sido utilizado con exito en el estudio de procesos biogeoquimicos en los oceanos, deposito atmosferico y contaminacion antropogenica, procesos sedimentarios y geocronologia de sedimentos.

  3. Study of indicators aggregation techniques for the selection of a new nuclear reactor for Mexico; Estudio de tecnicas de agregacion de indicadores para la seleccion de un nuevo reactor nuclear para Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Barragan M, A.M.; Martin del Campo M, C. [UNAM, Facultad de Ingenieria, 04510 Mexico D.F. (Mexico)]. e-mail: ale_bar_m@yahoo.com.mx

    2007-07-01

    A study on several aggregation techniques that can be used as multi criteria analysis methods, like important part of the methodology developed for the selection of a nuclear reactor for Mexico is described. In an arbitrary way three reactors were selected to be compared, these they are the AP1000 (Advance Passive from 1000 MWe), the PBMR (Pebble Bed Modular Reactor) and the GT-MHR (Gas Turbine Modular Helium). The evaluation approaches were classified in three categories: Economic, Socio-political and of safety and environment. In each category they were defined the more important evaluation indicators and then it was built a matrix with those values of each reactor. The four studied aggregation methods are described: Normalization, Linear deliberation, Fuzzy Logic and AHP (Analytic Hierarchy Process). The well-known aggregation mechanisms are those that are obtained of the lineal deliberation and of the normalization, which have demonstrated to give good results before the simplicity of their use. The fuzzy logic has the advantage that it allows to manage qualitative and quantitative information simultaneously without the aggregation problems that are presented since in a conventional system the semantic pattern on that is based, it is provided by the theory of the diffuse groups that has demonstrated in other areas of the knowledge a better approach to the reality, when admitting that the nature has shades and that the decisions take in function of a wide range of possibilities and of approaches in contradictory occasions or in conflict, all equally worth. The Analytic Hierarchical Process (AHP) that consists in formalizing the intuitive understanding of a multi criteria complex problem, by means of the construction of a hierarchical model that allows the decision agent to structure the problem in visual form, giving him the form of a hierarchy of attributes (global objective of the problem, approaches and alternative). Finally, using the matrix of initiators

  4. Radioactive tracers and the cracking modelings

    International Nuclear Information System (INIS)

    Bettens, B.

    1982-01-01

    The use of tracers (3H and 14 C) labelled in specific positions is an intensive contribution to the understanding and the revealing of the very often complex cracking modeling. The pyrolytic decay of the phenol and the cresols, of the aniline, of the phenantrene and its hydrogenated derived products were investigated and are presented as examples. The decay mechanisms give a theoretical knowledge of the thermal cracking and allow to handle the results on an industrial scale. (AF)

  5. The medical applications of radioactive tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, J.G.

    1947-12-31

    This report provides a broad yet in depth overview of the use of radioactive materials as tracers in medicine and biology for the period of 1935--1947. Particular attention is paid to is of radio-sodium, radio-iodine, radio-iron, radio-phosphorus, radio-strontium, and fission products. The main thrust of this paper is human rather than animal work and focuses in work that has been published.

  6. Combined use of heat and saline tracer to estimate aquifer properties in a forced gradient test

    Science.gov (United States)

    Colombani, N.; Giambastiani, B. M. S.; Mastrocicco, M.

    2015-06-01

    Usually electrolytic tracers are employed for subsurface characterization, but the interpretation of tracer test data collected by low cost techniques, such as electrical conductivity logging, can be biased by cation exchange reactions. To characterize the aquifer transport properties a saline and heat forced gradient test was employed. The field site, located near Ferrara (Northern Italy), is a well characterized site, which covers an area of 200 m2 and is equipped with a grid of 13 monitoring wells. A two-well (injection and pumping) system was employed to perform the forced gradient test and a straddle packer was installed in the injection well to avoid in-well artificial mixing. The contemporary continuous monitor of hydraulic head, electrical conductivity and temperature within the wells permitted to obtain a robust dataset, which was then used to accurately simulate injection conditions, to calibrate a 3D transient flow and transport model and to obtain aquifer properties at small scale. The transient groundwater flow and solute-heat transport model was built using SEAWAT. The result significance was further investigated by comparing the results with already published column experiments and a natural gradient tracer test performed in the same field. The test procedure shown here can provide a fast and low cost technique to characterize coarse grain aquifer properties, although some limitations can be highlighted, such as the small value of the dispersion coefficient compared to values obtained by natural gradient tracer test, or the fast depletion of heat signal due to high thermal diffusivity.

  7. Luminescent two-color tracer particles for simultaneous velocity and temperature measurements in microfluidics

    International Nuclear Information System (INIS)

    Massing, J; Kähler, C J; Cierpka, C; Kaden, D

    2016-01-01

    The simultaneous and non-intrusive measurement of temperature and velocity fields in flows is of great scientific and technological interest. To sample the velocity and temperature, tracer particle based approaches have been developed, where the velocity is measured using PIV or PTV and the temperature is obtained from the intensity (LIF, thermographic phosphors) or frequency (TLC) of the light emitted or reflected by the tracer particles. In this article, a measurement technique is introduced, that relates the luminescent intensity ratio of individual dual-color luminescent tracer particles to temperature. Different processing algorithms are tested on synthetic particle images and compared with respect to their accuracy in estimating the intensity ratio. Furthermore, polymer particles which are doped with the temperature sensitive dye europium (III) thenoyltrifluoroacetonate (EuTTA) and the nearly temperature insensitive reference dye perylene are characterized as valid tracers. The results show a reduction of the temperature measurement uncertainty of almost 40% (95% confidence interval) compared to previously reported luminescent particle based measurement techniques for microfluidics. (paper)

  8. Tracer technology modeling the flow of fluids

    CERN Document Server

    Levenspiel, Octave

    2012-01-01

    A vessel’s behavior as a heat exchanger, absorber, reactor, or other process unit is dependent upon how fluid flows through the vessel.  In early engineering, the designer would assume either plug flow or mixed flow of the fluid through the vessel.  However, these assumptions were oftentimes inaccurate, sometimes being off by a volume factor of 100 or more.  The result of this unreliable figure produced ineffective products in multiple reaction systems.   Written by a pioneering researcher in the field of chemical engineering, the tracer method was introduced to provide more accurate flow data.  First, the tracer method measured the actual flow of fluid through a vessel.  Second, it developed a suitable model to represent the flow in question.  Such models are used to follow the flow of fluid in chemical reactors and other process units, like in rivers and streams, or solid and porous structures.  In medicine, the tracer method is used to study the flow of chemicals—harmful  and harmless—in the...

  9. The ATLAS DDM Tracer monitoring framework

    International Nuclear Information System (INIS)

    Zang Dongsong; Garonne, Vincent; Barisits, Martin; Lassnig, Mario; Andrew Stewart, Graeme; Molfetas, Angelos; Beermann, Thomas

    2012-01-01

    The DDM Tracer monitoring framework is aimed to trace and monitor the ATLAS file operations on the Worldwide LHC Computing Grid. The volume of traces has increased significantly since the framework was put in production in 2009. Now there are about 5 million trace messages every day and peaks can be near 250Hz, with peak rates continuing to climb, which gives the current structure a big challenge. Analysis of large datasets based on on-demand queries to the relational database management system (RDBMS), i.e. Oracle, can be problematic, and have a significant effect on the database's performance. Consequently, We have investigated some new high availability technologies like messaging infrastructure, specifically ActiveMQ, and key-value stores. The advantages of key value store technology are that they are distributed and have high scalability; also their write performances are usually much better than RDBMS, all of which are very useful for the Tracer monitoring framework. Indexes and distributed counters have been also tested to improve query performance and provided almost real time results. In this paper, the design principles, architecture and main characteristics of Tracer monitoring framework will be described and examples of its usage will be presented.

  10. Novel tracer for radiation treatment planning

    International Nuclear Information System (INIS)

    Schwarzenboeck, S.; Krause, B.J.; Herrmann, K.; Gaertner, F.; Souvatzoglou, M.; Klaesner, B.

    2011-01-01

    PET and PET/CT with innovative tracers gain increasing importance in diagnosis and therapy management, and radiation treatment planning in radio-oncology besides the widely established FDG. The introduction of [ 18 F]Fluorothymidine ([ 18 F]FLT) as marker of proliferation, [ 18 F]Fluoromisonidazole ([ 18 F]FMISO) and [ 18 F]Fluoroazomycin-Arabinoside ([ 18 F]FAZA) as tracer of hypoxia, [ 18 F]Fluoroethyltyrosine ([ 18 F]FET) and [ 11 C]Methionine for brain tumour imaging, [ 68 Ga]DOTATOC for somatostatin receptor imaging, [ 18 F]FDOPA for dopamine synthesis and radioactively labeled choline derivatives for imaging phospholipid metabolism have opened novel approaches to tumour imaging. Some of these tracers have already been implemented into radio-oncology: Amino acid PET and PET/CT have the potential to optimise radiation treatment planning of brain tumours through accurate delineation of tumour tissue from normal tissue, necrosis and edema. Hypoxia represents a major therapeutic problem in radiation therapy. Hypoxia imaging is very attractive as it may allow to increase the dose in hypoxic tumours potentially allowing for a better tumour control. Advances in hybrid imaging, i.e. the introduction of MR/PET, may also have an impact in radio-oncology through synergies related to the combination of molecular signals of PET and a high soft tissue contrast of MRI as well as functional MRI capabilities. (orig.)

  11. Commercial applications of perfluorocarbon tracer (PFT) technology

    International Nuclear Information System (INIS)

    Dietz, R.N.

    1991-06-01

    Tracer technology can be successfully applied to many leak-checking and monitoring evaluations of operating systems (e.g., building HVACs), manufacturing processes and products (e.g., air conditioners), and subsurface components and systems (e.g., underground storage tanks). Perfluorocarbon tracer (PFT) technology is the most sensitive of all tracer technologies because the ambient background levels of the five (5) routinely-used PFTs are in the range of parts per 10 15 parts of air (i.e., parts per quadrillion-ppq) and this technology's instrumentation can measure down to those levels. The effectiveness of this technology is achieved both in terms of cost (very little PFT need to be used) and detectability; for example, very small leaks can be rapidly detected. The PFT compounds, which are environmentally and biologically safe to use, are commercially available as are the sampling and analysis instrumentation. This presentation concerns (1) the steps being taken to commercialize this technology, (2) new applications of processes currently under study, and (3) applications in areas of use that will be particularly beneficial to the environment. 21 refs., 2 figs., 2 tabs

  12. Individual Tracer Atoms in an Ultracold Dilute Gas

    Science.gov (United States)

    Hohmann, Michael; Kindermann, Farina; Lausch, Tobias; Mayer, Daniel; Schmidt, Felix; Lutz, Eric; Widera, Artur

    2017-06-01

    We report on the experimental investigation of individual Cs atoms impinging on a dilute cloud of ultracold Rb atoms with variable density. We study the relaxation of the initial nonthermal state and detect the effect of single collisions which has so far eluded observation. We show that, after few collisions, the measured spatial distribution of the tracer atoms is correctly described by a Langevin equation with a velocity-dependent friction coefficient, over a large range of Knudsen numbers. Our results extend the simple and effective Langevin treatment to the realm of light particles in dilute gases. The experimental technique developed opens up the microscopic exploration of a novel regime of diffusion at the level of individual collisions.

  13. Tracers in measurement and analysis of river pollution

    International Nuclear Information System (INIS)

    Moreira, R.M.; Castro, J.O.N.M. de

    1986-01-01

    Pollutant matter discharged into streams undergo, a process of dispersion caused by turbulence and shear dispersion. A physical dilution ensues, to which in some cases is added the decay of the pollutant. Hence, a natural process of self purification results and this characteristic of the stream has a most important ecological and economical meaning. Its evaluation allows the optimization of effluent treatment works, at the same time ensuring the compliance with established water quality criteria. The use of tracers, together with the calibration of mathematical models and with the information they afford, make possible the impact assessment and the adaptive control of the effects of pollutant disposal into streams. This paper classifies the models apropriate for each discharge type, discusses the calibration methods and presents an application fo these techniques to a real situation of a medium size river. (Author) [pt

  14. Study on the flow state of groundwater by isotope tracer

    International Nuclear Information System (INIS)

    Lin Tong; Chen Jiansheng; Chen Liang

    2008-01-01

    Radioisotope logging technique is an effective method to evaluate groundwater movement. Moving with the water, the isotope tracer distributes differently in different flow states. According to the depth and time distribution of radioactivity, flow state of the groundwater can be determined. In this paper, different flow states, i.e. laminar flow, turbulent flow and mixing flow, are analyzed, and calculation of the flow velocity is discussed. Also, we discuss how to distinguish the laminar flow part and turbulent part in a mixing flow. If one judges the flow state incorrectly, the error of flow velocity will be huge, hence the importance of flow state analysis. Finally, some problems in the practical projects and measuring methods are concluded. (authors)

  15. Random walk of passive tracers among randomly moving obstacles.

    Science.gov (United States)

    Gori, Matteo; Donato, Irene; Floriani, Elena; Nardecchia, Ilaria; Pettini, Marco

    2016-04-14

    This study is mainly motivated by the need of understanding how the diffusion behavior of a biomolecule (or even of a larger object) is affected by other moving macromolecules, organelles, and so on, inside a living cell, whence the possibility of understanding whether or not a randomly walking biomolecule is also subject to a long-range force field driving it to its target. By means of the Continuous Time Random Walk (CTRW) technique the topic of random walk in random environment is here considered in the case of a passively diffusing particle among randomly moving and interacting obstacles. The relevant physical quantity which is worked out is the diffusion coefficient of the passive tracer which is computed as a function of the average inter-obstacles distance. The results reported here suggest that if a biomolecule, let us call it a test molecule, moves towards its target in the presence of other independently interacting molecules, its motion can be considerably slowed down.

  16. A New Kind of Single-Well Tracer Test for Assessing Subsurface Heterogeneity

    Science.gov (United States)

    Hansen, S. K.; Vesselinov, V. V.; Lu, Z.; Reimus, P. W.; Katzman, D.

    2017-12-01

    Single-well injection-withdrawal (SWIW) tracer tests have historically been interpreted using the idealized assumption of tracer path reversibility (i.e., negligible background flow), with background flow due to natural hydraulic gradient being an un-modeled confounding factor. However, we have recently discovered that it is possible to use background flow to our advantage to extract additional information about the subsurface. To wit: we have developed a new kind of single-well tracer test that exploits flow due to natural gradient to estimate the variance of the log hydraulic conductivity field of a heterogeneous aquifer. The test methodology involves injection under forced gradient and withdrawal under natural gradient, and makes use of a relationship, discovered using a large-scale Monte Carlo study and machine learning techniques, between power law breakthrough curve tail exponent and log-hydraulic conductivity variance. We will discuss how we performed the computational study and derived this relationship and then show an application example in which our new single-well tracer test interpretation scheme was applied to estimation of heterogeneity of a formation at the chromium contamination site at Los Alamos National Laboratory. Detailed core hole records exist at the same site, from which it was possible to estimate the log hydraulic conductivity variance using a Kozeny-Carman relation. The variances estimated using our new tracer test methodology and estimated by direct inspection of core were nearly identical, corroborating the new methodology. Assessment of aquifer heterogeneity is of critical importance to deployment of amendments associated with in-situ remediation strategies, since permeability contrasts potentially reduce the interaction between amendment and contaminant. Our new tracer test provides an easy way to obtain this information.

  17. Use of a variable tracer infusion method to determine glucose turnover in humans

    International Nuclear Information System (INIS)

    Molina, J.M.; Baron, A.D.; Edelman, S.V.; Brechtel, G.; Wallace, P.; Olefsky, J.M.

    1990-01-01

    The single-compartment pool fraction model, when used with the hyperinsulinemic glucose clamp technique to measure rates of glucose turnover, sometimes underestimates true rates of glucose appearance (Ra) resulting in negative values for hepatic glucose output (HGO). We focused our attention on isotope discrimination and model error as possible explanations for this underestimation. We found no difference in [3-3H] glucose specific activity in samples obtained simultaneously from the femoral artery and vein (2,400 +/- 455 vs. 2,454 +/- 522 dpm/mg) in 6 men during a hyperinsulinemic euglycemic clamp study where insulin was infused at 40 mU.m-2.min-1 for 3 h; therefore, isotope discrimination did not occur. We compared the ability of a constant (0.6 microCi/min) vs. variable tracer infusion method (tracer added to the glucose infusate) to measure non-steady-state Ra during hyperinsulinemic clamp studies. Plasma specific activity fell during the constant tracer infusion studies but did not change from base line during the variable tracer infusion studies. By maintaining a constant plasma specific activity the variable tracer infusion method eliminates uncertainty about changes in glucose pool size. This overcame modeling error and more accurately measures non-steady-state Ra (P less than 0.001 by analysis of variance vs. constant infusion method). In conclusion, underestimation of Ra determined isotopically during hyperinsulinemic clamp studies is largely due to modeling error that can be overcome by use of the variable tracer infusion method. This method allows more accurate determination of Ra and HGO under non-steady-state conditions

  18. Partitioning and interfacial tracers for differentiating NAPL entrapment configuration: column-scale investigation.

    Science.gov (United States)

    Dai, D; Barranco, F T; Illangasekare, T H

    2001-12-15

    Research on the use of partitioning and interfacial tracers has led to the development of techniques for estimating subsurface NAPL amount and NAPL-water interfacial area. Although these techniques have been utilized with some success at field sites, current application is limited largely to NAPL at residual saturation, such as for the case of post-remediation settings where mobile NAPL has been removed through product recovery. The goal of this study was to fundamentally evaluate partitioning and interfacial tracer behavior in controlled column-scale test cells for a range of entrapment configurations varying in NAPL saturation, with the results serving as a determinant of technique efficacy (and design protocol) for use with complexly distributed NAPLs, possibly at high saturation, in heterogeneous aquifers. Representative end members of the range of entrapment configurations observed under conditions of natural heterogeneity (an occurrence with residual NAPL saturation [discontinuous blobs] and an occurrence with high NAPL saturation [continuous free-phase LNAPL lens]) were evaluated. Study results indicated accurate prediction (using measured tracer retardation and equilibrium-based computational techniques) of NAPL amount and NAPL-water interfacial area for the case of residual NAPL saturation. For the high-saturation LNAPL lens, results indicated that NAPL-water interfacial area, but not NAPL amount (underpredicted by 35%), can be reasonably determined using conventional computation techniques. Underprediction of NAPL amount lead to an erroneous prediction of NAPL distribution, as indicated by the NAPL morphology index. In light of these results, careful consideration should be given to technique design and critical assumptions before applying equilibrium-based partitioning tracer methodology to settings where NAPLs are complexly entrapped, such as in naturally heterogeneous subsurface formations.

  19. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation

    DEFF Research Database (Denmark)

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker

    2018-01-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment...... plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument...... precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument...

  20. Asian Tracer Experiment and Atmospheric Modeling (TEAM) Project: Draft Field Work Plan for the Asian Long-Range Tracer Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Allwine, K Jerry; Flaherty, Julia E.

    2007-08-01

    This report provides an experimental plan for a proposed Asian long-range tracer study as part of the international Tracer Experiment and Atmospheric Modeling (TEAM) Project. The TEAM partners are China, Japan, South Korea and the United States. Optimal times of year to conduct the study, meteorological measurements needed, proposed tracer release locations, proposed tracer sampling locations and the proposed durations of tracer releases and subsequent sampling are given. Also given are the activities necessary to prepare for the study and the schedule for completing the preparation activities leading to conducting the actual field operations. This report is intended to provide the TEAM members with the information necessary for planning and conducting the Asian long-range tracer study. The experimental plan is proposed, at this time, to describe the efforts necessary to conduct the Asian long-range tracer study, and the plan will undoubtedly be revised and refined as the planning goes forward over the next year.

  1. Estudios sobre Plantas Andinas, X

    Directory of Open Access Journals (Sweden)

    Cuatrecasas José

    1967-09-01

    Full Text Available Durante la preparación del género Baccharis para Prima Flora Colombiana tuve que estudiar gran número de especies andinas, tropicales y extratropicales de fuera de Colombia; el objeto principal de tales estudios fue el de tipificar las especies íntimamente relacionadas con las colombianas y establecer su diferenciación taxonómica. La consulta de los tipos específicos y la identificación de gran número de colecciones procedentes de las regiones andinas hasta el sur del continente americano permitió precisar el concepto de bastantes especies y de su área geográfica, al mismo tiempo que el establecimiento de numerosas sinonimias.  La mayor parte de las novedades taxonómicas y de los comentarios derivados de tal estudio va incluída en el texto de las Astereae de Colombia a publicar en breve. El objeto de este artículo es dar a conocer otra parte de las novedades relativas a especies andinas de los países vecinos y describir varias entidades taxonómicas deficientemente conocidas, incorporando a su conocimiento los resultados de muchas disecciones llevadas a cabo en los mencionados estudios.  El trabajo basico para estas notas fue hecho en la Smithsonian Institution; se consultaron también las colecciones de los herbarios europeos de Londres, París, Florencia, Ginebra y Madrid en viaje hecho en otoño de 1963. National Science Foundation de Washington D.C. subvencionó los trabajos.

  2. LOS ESTUDIOS DE POBREZA URBANA

    Directory of Open Access Journals (Sweden)

    Rina De León Herrera

    2007-08-01

    Full Text Available En este artículo se intenta mostrar en forma sucinta la evolución de los estudios de pobreza urbana; se retoma para ello la producción escritural de investigadores que han hecho aportes valiosos sobre la temática en diferentes épocas y espacios geográficos. La información se ha organizado en dos unidades de análisis: la producción escritural en los países desarrollados y en los países en desarrollo.

  3. Esclavizada en los Estudios Poscoloniales

    Directory of Open Access Journals (Sweden)

    Nellys Montenegro De la Hoz

    2014-01-01

    Full Text Available Este ensayo va a centrarse en el análisis de las formas de resis - tencia e identidad esclavizada presentes en Changó, el gran putas de Manuel Zapata Olivella, a través del análisis de los discur - sos hegemónicos y subalternos que hacían parte del sistema de poder, y la intervención de las teorías o estudios poscoloniales que cuestionan dichas perspectivas para redefinir las diferencias de las identidades contradictorias y desarrollar de esta manera literaturas deslindadas de las estructuras ideológicas y hegemónicas.

  4. The use of yield tracers for the determination of aplha-emitting actinides in the marine environment

    International Nuclear Information System (INIS)

    Harvey, B.R.; Lovett, M.B.

    1984-01-01

    The need for yield tracers and their general analytical application is briefly discussed and more fully expanded in the context of the radiochemical determination of alpha-emitting actinides. The important alpha-emitting nuclides of the actinide elements found in the marine environment are listed. The environmental significance and analytical implications arising from the multiplicity of valency states found amongst the earlier members of the actinide series are noted. The tracers that are available for analyses and their selection and suitability for particular applications are discussed and the general precautions that need to be observed in their use are given. Use of the dual tracer technique in the study of speciation of the actinides in the marine environment is discussed with special reference to plutonium in sea water. The limited applicability of plutonium as a yield tracer in the study of neptunium speciation is noted and the latest developments in the investigation of 235 Np as an alternative tracer for neptunium are given. The possibility of the joint use of americium and curium nuclides as tracers in the study of the speciation of these two elements is explored. (orig.)

  5. An uncertainty inclusive un-mixing model to identify tracer non-conservativeness

    Science.gov (United States)

    Sherriff, Sophie; Rowan, John; Franks, Stewart; Fenton, Owen; Jordan, Phil; hUallacháin, Daire Ó.

    2015-04-01

    Sediment fingerprinting is being increasingly recognised as an essential tool for catchment soil and water management. Selected physico-chemical properties (tracers) of soils and river sediments are used in a statistically-based 'un-mixing' model to apportion sediment delivered to the catchment outlet (target) to its upstream sediment sources. Development of uncertainty-inclusive approaches, taking into account uncertainties in the sampling, measurement and statistical un-mixing, are improving the robustness of results. However, methodological challenges remain including issues of particle size and organic matter selectivity and non-conservative behaviour of tracers - relating to biogeochemical transformations along the transport pathway. This study builds on our earlier uncertainty-inclusive approach (FR2000) to detect and assess the impact of tracer non-conservativeness using synthetic data before applying these lessons to new field data from Ireland. Un-mixing was conducted on 'pristine' and 'corrupted' synthetic datasets containing three to fifty tracers (in the corrupted dataset one target tracer value was manually corrupted to replicate non-conservative behaviour). Additionally, a smaller corrupted dataset was un-mixed using a permutation version of the algorithm. Field data was collected in an 11 km2 river catchment in Ireland. Source samples were collected from topsoils, subsoils, channel banks, open field drains, damaged road verges and farm tracks. Target samples were collected using time integrated suspended sediment samplers at the catchment outlet at 6-12 week intervals from July 2012 to June 2013. Samples were dried (affected whereas uncertainty was only marginally impacted by the corrupted tracer. Improvement of uncertainty resulted from increasing the number of tracers in both the perfect and corrupted datasets. FR2000 was capable of detecting non-conservative tracer behaviour within the range of mean source values, therefore, it provided a more

  6. STRATEGIES FOR QUANTIFYING PET IMAGING DATA FROM TRACER STUDIES OF BRAIN RECEPTORS AND ENZYMES.

    Energy Technology Data Exchange (ETDEWEB)

    Logan, J.

    2001-04-02

    A description of some of the methods used in neuroreceptor imaging to distinguish changes in receptor availability has been presented in this chapter. It is necessary to look beyond regional uptake of the tracer since uptake generally is affected by factors other than the number of receptors for which the tracer has affinity. An exception is the infusion method producing an equilibrium state. The techniques vary in complexity some requiring arterial blood measurements of unmetabolized tracer and multiple time uptake data. Others require only a few plasma and uptake measurements and those based on a reference region require no plasma measurements. We have outlined some of the limitations of the different methods. Laruelle (1999) has pointed out that test/retest studies to which various methods can be applied are crucial in determining the optimal method for a particular study. The choice of method will also depend upon the application. In a clinical setting, methods not involving arterial blood sampling are generally preferred. In the future techniques for externally measuring arterial plasma radioactivity with only a few blood samples for metabolite correction will extend the modeling options of clinical PET. Also since parametric images can provide information beyond that of ROI analysis, improved techniques for generating such images will be important, particularly for ligands requiring more than a one-compartment model. Techniques such as the wavelet transform proposed by Turkheimer et al. (2000) may prove to be important in reducing noise and improving quantitation.

  7. Nuclear techniques in hydrology

    International Nuclear Information System (INIS)

    Bahadur, J.; Saxena, R.K.

    1974-01-01

    Several types of sealed radioactive sources, stable isotopes and water soluble radioactive tracers, used by different investigators, have been listed for studying the dynamic behaviour of water in nature. In general, all the facets of hydrological cycle, are amenable to these isotopic techniques. It is recommended that environmental isotopes data collection should be started for studying the water balance and also the interrelationships between surface and subsurface water in various rivers catchments with changing physical, geological and climatic parameters. (author)

  8. CityFlux perfluorocarbon tracer experiments

    Directory of Open Access Journals (Sweden)

    F. K. Petersson

    2010-07-01

    Full Text Available In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m.

    The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site.

    Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail.

    The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this.

    The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

  9. CityFlux perfluorocarbon tracer experiments

    Science.gov (United States)

    Petersson, F. K.; Martin, D.; White, I. R.; Henshaw, S. J.; Nickless, G.; Longley, I.; Percival, C. J.; Gallagher, M.; Shallcross, D. E.

    2010-07-01

    In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m. The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site. Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail. The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this. The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

  10. Refinamientos en la reconstrucción del tercio superior auricular con la técnica de Davis: Estudio anatómico y serie clínica Refinements on reconstruction of auricular upper pole defects with Davi's technique: Anatomical study and clinical series

    Directory of Open Access Journals (Sweden)

    S. Llanos

    2009-06-01

    Full Text Available Los defectos del tercio superior auricular son un desafío reconstructivo. Están descritas diferentes técnicas quirúrgicas para este fin con resultados a veces desfavorables Realizamos un estudio anatómico en cadáveres frescos que mostró la presencia constante de un pedículo neurovascular que penetra la raíz del hélix. Mostramos la localización y los diámetros de los vasos. Basándonos en este estudio anatómico, presentamos una serie de 10 casos consecutivos tratados por el autor principal. Analizamos la etiología, técnica quirúrgica, complicaciones y resultado a largo plazo. La técnica del autor introduce refinamientos a la técnica de Davis, el cual usa un colgajo condrocutáneo de concha auricular basado en la rama superior de la arteria temporal superficial y un colgajo cutáneo axial de base superior basado en la arteria retroauricular, para crear el nuevo hélix auricular superior. El aspecto posterior de este colgajo condrocutáneo se cubre con un injerto de piel total. En un segundo tiempo empleamos una zetaplastia de la base del hélix que nos dará una mejor forma. El estudio anatómico demostró la presencia de un pedículo neurovascular que penetra la raíz del hélix. La serie clínica está compuesta por 8 defectos postraumáticos, una quemadura eléctrica y un tumor de piel. Todos los colgajos condrocutáneos de concha auricular sobrevivieron comprobándose la seguridad del pedículo del hélix. Dos colgajos retroauriculares presentaron sufrimiento vascular transitorio distal, uno de ellos con recuperación completa y otro con necrosis distal mínima. Dos casos sufrieron pérdida parcial del injerto de piel total. Durante el desarrollo de la serie descubrimos algunos detalles de la técnica quirúrgica, que ahora discutimos en el artículo. Todos los pacientes recuperaron el contorno auricular, obteniendo los mejores resultados en aquellos en los que se aplicaron los refinamientos descritos. En conclusión, creemos

  11. Measurements of industrial fugitive emissions by the FTIR Tracer Method (FTM)

    International Nuclear Information System (INIS)

    Mellqvist, J.; Arlander, B.; Galle, B.; Bergqvist, B.

    1996-01-01

    A new method called the FTIR Tracer Method (FTM), has been developed for measuring and quantifying fugitive (diffuse) emissions of hydrocarbons. The method has been evaluated in field experiments which were conducted in the vicinity of several petrochemical plants and an oil refinery during 1993-1995. The technique is based on concentration measurements with infrared remote sensing by Long Path Fourier Transform InfraRed (LPFTIR), combined with tracer releases. The field experiments show the FTM to be very useful for mass flux measurements of both alkanes and alkenes and that the measurements are consistent with the conventional SF 6 method. However, the technique needs to be further validated and a more thorough understanding of the measurement uncertainties have to be achieved

  12. Survey on industrial applications of radioactive tracers

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Yoo, Young Soo; Lee, Jong Doo; Awh, Ok Doo; Kim, Jun Hyung

    1986-12-01

    Current status and future feasibilities of industrial tracer applications in the Republic of Korea have been surveyed. Microleak detection using Krypton-85 in eight electronics industrial companies, and efficiency tests of steam generators in four nuclear power plants using Sodium-24 are the principal applications in Korea. Future applications are expected for mercury inventory in one soda industrial company, and alkali movement studies in two cement industrial companies. Korean industries expressed deep interest in leak detection in underground pipelines, abrasion/corrosion studies, mixing rate and residence time measurements. (Author)

  13. Pharmaceuticals as Groundwater Tracers - Applications and Limitations

    Science.gov (United States)

    Scheytt, T. J.; Mersmann, P.; Heberer, T.

    2003-12-01

    Pharmaceutically active substances and metabolites are found at concentrations up to the microgram/L-level in groundwater samples from the Berlin (Germany) area and from several other places world wide. Among the compounds detected in groundwater are clofibric acid, propyphenazone, diclofenac, ibuprofen, and carbamazepine. Clofibric acid, the active metabolite of clofibrate and etofibrate (blood lipid regulators) is detected in groundwater at maximum concentrations of 7300 ng/L. Among the most important input paths of drugs are excretion and disposal into the sewage system. Groundwater contamination is likely to be due to leaky sewage systems, influent streams, bank filtration, and irrigation with effluent water from sewage treatment plants. There are no known natural sources of the above mentioned pharmaceuticals. The use of pharmaceuticals as tracers may include: (a) Quantification of infiltration from underground septic tanks (b) Detection of leaky sewage systems / leaky sewage pipes (c) Estimation of the effectiveness of sewage treatment plants (d) Identification of transport pathways of other organic compounds (e) Quantification of surface water / groundwater interaction (f) Characterization of the biodegradation potential. The use of pharmaceuticals as tracers is limited by variations in input. These variations depend on the amount of drugs prescribed and used in the study area, the social structure of the community, the amount of hospital discharge, and temporal concentration variations. Furthermore, the analysis of trace amounts of pharmaceuticals is sophisticated and expensive and may therefore limit the applicability of pharmaceuticals as tracers. Finally, the transport and degradation behavior of pharmaceuticals is not fully understood. Preliminary experiments in the laboratory were conducted using sediment material and groundwater from the Berlin area to evaluate the transport and sorption behavior of selected drugs. Results of the column experiments

  14. Tracer preparate and method for its production

    International Nuclear Information System (INIS)

    Pratt, F.P.; Gagnon, D.

    1978-01-01

    The injectable tracer preparate for investigations to determine the blood flow in organs or the effect of drugs on the blood flow consists of a core of ion exchanger resin coated with polyfuran or a polymer which is the reaction product of a monomer catalysable by acid or base. The nuclei have a diameter of 10 to 200 micron, the coating thickness is between 1 and 3 micron. Ions of Ce 141, Cr 51, Sr 85, Sr 46 or Co 57 of strength 0.1-100 millicurie are adsorbed on the nucleus. (DG) [de

  15. Nested Tracer Studies In Catchment Hydrology: Towards A Multiscale Understanding of Runoff Generation and Catchment Funtioning

    Science.gov (United States)

    Soulsby, C.; Rodgers, P.; Malcolm, I. A.; Dunn, S.

    Geochemical and isotopic tracers have been shown to have widespread utility in catch- ment hydrology in terms of identifying hydrological source areas and characterising residence time distributions. In many cases application of tracer techniques has pro- vided insights into catchment functioning that could not be obtained from hydromet- ric and/or modelling studies alone. This paper will show how the use of tracers has contributed to an evolving perceptual model of hydrological pathways and runoff gen- eration processes in catchments in the Scottish highlands. In particular the paper will focus on the different insights that are gained at three different scales of analysis; (a) nested sub-catchments within a mesoscale (ca. 200 square kilometers) experimen- tal catchment; (b) hillslope-riparian interactions and (c) stream bed fluxes. Nested hydrometric and hydrochemical monitoring within the mesoscale Feugh catchment identified three main hydrological response units: (i) plateau peatlands which gener- ated saturation overland flow in the catchment headwaters, (ii) steep valley hillslopes which drain from the plateaux into (iii) alluvial and drift aquifers in the valley bottoms. End Member Mixing Analysis (EMMA) in 8 nested sub-catchments indicated that that stream water tracer concentrations can be modelled in terms of 2 dominant runoff pro- cesses; overland flow from the peat and groundwater from the drift aquifers. Ground- water contributions generally increased with catchment size, though this was moder- ated by the characteristics of individual sub-basins, with drift cover being particularly important. Hillslope riparian interactions were also examined using tracers, hydromet- ric data and a semi-distributed hydrological model. This revealed that in the glaciated, drift covered terrain of the Scottish highlands, extensive valley bottom aquifers effec- tively de-couple hillslope waters from the river channel. Thus, riparian groundwater appears to significantly

  16. Novel S-35 Intrinsic Tracer Method for Determining Groundwater Travel Time near Managed Aquifer Recharge Facilities

    Science.gov (United States)

    Urióstegui, S. H.; Bibby, R. K.; Esser, B. K.; Clark, J. F.

    2013-12-01

    Identifying groundwater travel times near managed aquifer recharge (MAR) facilities is a high priority for protecting public and environmental health. For MAR facilities in California that incorporate tertiary wastewater into their surface-spreading recharge practices, the target subsurface residence time is >9 months to allow for the natural inactivation and degradation of potential contaminants (less time is needed for full advanced treated water). Established intrinsic groundwater tracer techniques such as tritium/helium-3 dating are unable to resolve timescales of method using a naturally occurring radioisotope of sulfur, sulfur-35 (S-35). After its production in the atmosphere by cosmic ray interaction with argon, S-35 enters the hydrologic cycle as dissolved sulfate through precipitation The short half-life of S-35 (3 months) is ideal for investigating recharge and transport of MAR groundwater on the method, however, has not been applied to MAR operations because of the difficulty in measuring S-35 with sufficient sensitivity in high-sulfate waters. We have developed a new method and have applied it at two southern California MAR facilities where groundwater travel times have previously been characterized using deliberate tracers: 1) Rio Hondo Spreading Grounds in Los Angeles County, and 2) Orange County Groundwater Recharge Facilities in Orange County. Reasonable S-35 travel times of method also identified seasonal patterns in subsurface travel times, which may not be revealed by a deliberate tracer study that is dependent on the hydrologic conditions during the tracer injection period.

  17. Determination of the resident time distribution (RTD) in copper concentrate drying plants using radioactive tracers

    International Nuclear Information System (INIS)

    Diaz V, Francisco J.; Duran P, Oscar U.; Hernandez A, Fernando A.

    1996-01-01

    This paper is a study on the drying process of copper concentrate, on two fluidized bed dryers at Fundicion Caletones, Division El Teniente, Codelco-Chile. The problem was investigated by experimental determination of the resident Time Distribution (RTD) for the material to be dry and by an analysis of the influence of the grain size in the drying process. The stimulus-response technique was used in the experiments, where the stimulation was a pulse of an adequate radioactive tracer injected at the dryer's input. Under these conditions, the response obtained at the dryer's outputs, i.e., the concentration variation curve as a function of time, represents directly the RTD of the system between the injection and measuring points. The tracer used was the same material to be dried, and it was irradiated with neutrons in the nuclear reactor at La Reina Nuclear Centre, thus producing a solid gamma radiation emitter tracer of identical behaviour as the material under study. The approximate activity of each sample was equivalent to 8 mCi of Cu-64 at the time of the injection and the measurement of the tracer was made on-line using NaI(Tl) gamma radiation detectors. The results obtained showed average times less than the estimated and would indicate a fast drying using minimum volume in the dryer. The drying of the fine particles was three times faster than the coarse ones. (author)

  18. Stratospheric temperatures and tracer transport in a nudged 4-year middle atmosphere GCM simulation

    Science.gov (United States)

    van Aalst, M. K.; Lelieveld, J.; Steil, B.; Brühl, C.; Jöckel, P.; Giorgetta, M. A.; Roelofs, G.-J.

    2005-02-01

    We have performed a 4-year simulation with the Middle Atmosphere General Circulation Model MAECHAM5/MESSy, while slightly nudging the model's meteorology in the free troposphere (below 113 hPa) towards ECMWF analyses. We show that the nudging 5 technique, which leaves the middle atmosphere almost entirely free, enables comparisons with synoptic observations. The model successfully reproduces many specific features of the interannual variability, including details of the Antarctic vortex structure. In the Arctic, the model captures general features of the interannual variability, but falls short in reproducing the timing of sudden stratospheric warmings. A 10 detailed comparison of the nudged model simulations with ECMWF data shows that the model simulates realistic stratospheric temperature distributions and variabilities, including the temperature minima in the Antarctic vortex. Some small (a few K) model biases were also identified, including a summer cold bias at both poles, and a general cold bias in the lower stratosphere, most pronounced in midlatitudes. A comparison 15 of tracer distributions with HALOE observations shows that the model successfully reproduces specific aspects of the instantaneous circulation. The main tracer transport deficiencies occur in the polar lowermost stratosphere. These are related to the tropopause altitude as well as the tracer advection scheme and model resolution. The additional nudging of equatorial zonal winds, forcing the quasi-biennial oscillation, sig20 nificantly improves stratospheric temperatures and tracer distributions.

  19. Measurements of waste tank passive ventilation rates using tracer gases

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Olsen, K.B.; Sklarew, D.S.; Evans, J.C.; Remund, K.M.

    1997-09-01

    This report presents the results of ventilation rate studies of eight passively ventilated high-level radioactive waste tanks using tracer gases. Head space ventilation rates were determined for Tanks A-101, AX-102, AX-103, BY-105, C-107, S-102, U-103, and U-105 using sulfur hexafluoride (SF 6 ) and/or helium (He) as tracer gases. Passive ventilation rates are needed for the resolution of several key safety issues. These safety issues are associated with the rates of flammable gas production and ventilation, the rates at which organic salt-nitrate salt mixtures dry out, and the estimation of organic solvent waste surface areas. This tracer gas study involves injecting a tracer gas into the tank headspace and measuring its concentration at different times to establish the rate at which the tracer is removed by ventilation. Tracer gas injection and sample collection were performed by SGN Eurisys Service Corporation and/or Lockheed Martin Hanford Corporation, Characterization Project Operations. Headspace samples were analyzed for He and SF 6 by Pacific Northwest National Laboratory (PNNL). The tracer gas method was first demonstrated on Tank S-102. Tests were conducted on Tank S-102 to verify that the tracer gas was uniformly distributed throughout the tank headspace before baseline samples were collected, and that mixing was sufficiently vigorous to maintain an approximately uniform distribution of tracer gas in the headspace during the course of the study. Headspace samples, collected from a location about 4 in away from the injection point and 15, 30, and 60 minutes after the injection of He and SF 6 , indicated that both tracer gases were rapidly mixed. The samples were found to have the same concentration of tracer gases after 1 hour as after 24 hours, suggesting that mixing of the tracer gas was essentially complete within 1 hour

  20. Atmospheric Gas Tracers in Groundwater: Theory, Sampling. Measurement and Interpretation

    International Nuclear Information System (INIS)

    Bayari, C.S.

    2002-01-01

    Some of the atmospheric gasses posses features that are sought in an environmental tracer of hydrogeologic interest. Among these, chlorofluorocarbons, sulfur hegzafluoride, carbon tetrachloride, methyl chloroform, krypton-85 etc. have found increasing use in groundwater age dating studies during the last ten years. This paper explains the theory of their use as tracer and discusses the major concerns as related to their sampling and analyses. Factors affecting their applicability and the approach to interpret tracer gas data is briefly outlined

  1. First research coordination meeting of the coordinated research project on validation of tracers and software for interwell investigations. Meeting report

    International Nuclear Information System (INIS)

    2004-01-01

    Interwell tracer test is an important reservoir engineering tool for secondary and tertiary recovery of oil. Most of the oil fields in many developing countries are in the stage of secondary recovery. Moreover, the oil industry remains at priority in these countries. It is therefore appropriate that further efforts should be channeled primarily towards promoting the radiotracer technology in this priority sector. The main purpose of interwell tracer tests in oil and geothermal reservoirs is to monitor qualitatively and quantitatively the fluid connections between injection and production wells and to map the flow field. Tracer is added into injection fluid via an injection well and observed in the surrounding production wells. Tracer response is then used to describe the flow pattern and obtain better understanding of the reservoir. This is important knowledge in order to optimize oil recovery. Radioactive tracers have been playing an important role in interwell tests because of their advantages, such as high sensitivity, stability and selectivity. Most of the information given by the tracer response curves cannot be obtained by means of other techniques. Interwell tracer test is also used in geothermal reservoirs to get better understanding of reservoir geology and to optimize production and re-injection program. High temperature geothermal resources are normally used for power generation. Whereas, middle and low temperature reservoirs are developing for civil living such as room heating and warm water supplying. Geothermal resource is now well recognized as a green and important part of follow-up energy sources in many developing countries. Over the years, the IAEA has contributed substantial funding and effort to the development of radiotracer technology and its transfer to developing Member States. Significant progress has been made enabling the countries to establish national radiotracer groups with an indigenous capacity to sustain and develop applications

  2. Determination of protein turnover parameters in athletes using 15N tracers

    International Nuclear Information System (INIS)

    Krumbiegel, P.; Kuehne, K.; Faust, H.; Bornhak, H.; Junghans, P.; Zerbes, H.

    1985-01-01

    In 2 adolescent female athletes engaged in technical-acrobatic sports the influence of a high protein diet on the protein turnover rate under training conditions was investigated by means of 15 N-glycine. Protein synthesis was significantly increased, whereas the utilization of nutritive nitrogen was decreased as expected. The 15 N tracer technique is well suited to determine the protein requirements under special training conditions

  3. Intracellular performance of tailored nanoparticle tracers in magnetic particle imaging

    Energy Technology Data Exchange (ETDEWEB)

    Arami, Hamed; Krishnan, Kannan M., E-mail: kannanmk@uw.edu [Department of Materials Science and Engineering, University of Washington, P.O. Box 352120, Seattle, Washington 98195-2120 (United States)

    2014-05-07

    Magnetic Particle Imaging (MPI) is a quantitative mass-sensitive, tracer-based imaging technique, with potential applications in various cellular imaging applications. The spatial resolution of MPI, in the first approximation, improves by decreasing the full width at half maximum (FWHM) of the field-derivative of the magnetization, dm/dH of the nanoparticle (NP) tracers. The FWHM of dm/dH depends critically on NPs’ size, size distribution, and their environment. However, there is limited information on the MPI performance of the NPs after their internalization into cells. In this work, 30 to 150 μg of the iron oxide NPs were incubated in a lysosome-like acidic buffer (0.2 ml, 20 mM citric acid, pH 4.7) and investigated by vibrating sample magnetometry, magnetic particle spectroscopy, transmission electron microscopy, and dynamic light scattering (DLS). The FWHM of the dm/dH curves of the NPs increased with incubation time and buffer to NPs ratio, consistent with a decrease in the median core size of the NPs from ∼20.1 ± 0.98 to ∼18.5 ± 3.15 nm. Further, these smaller degraded NPs formed aggregates that responded to the applied field by hysteretic reversal at higher field values and increased the FWHM. The rate of core size decrease and aggregation were inversely proportional to the concentration of the incubated NPs, due to their slower biodegradation kinetics. The results of this model experiment show that the MPI performance of the NPs in the acidic environments of the intracellular organelles (i.e., lysosomes and endosomes) can be highly dependent on their rate of internalization, residence time, and degradation.

  4. Compilation and analyses of results from cross-hole tracer tests with conservative tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Nordqvist, Rune; Harrstroem, Johan (Geosigma AB (Sweden))

    2010-09-15

    Radionuclide transport in hydrogeological formations is one of the key factors for the safety analysis of a future repository of nuclear waste. Tracer tests have therefore been an important field method within the SKB investigation programmes at several sites since the late 1970's. This report presents a compilation and analyses of results from cross-hole tracer tests with conservative tracers performed within various SKB investigations. The objectives of the study are to facilitate, improve and reduce uncertainties in predictive tracer modelling and to provide supporting information for SKB's safety assessment of a final repository of nuclear waste. More specifically, the focus of the report is the relationship between the tracer mean residence time and fracture hydraulic parameters, i.e. the relationship between mass balance aperture and fracture transmissivity, hydraulic diffusivity and apparent storativity. For 74 different combinations of pumping and injection section at six different test sites (Studsvik, Stripa, Finnsjoen, Aespoe, Forsmark, Laxemar), estimates of mass balance aperture from cross-hole tracer tests as well as transmissivity were extracted from reports or in the SKB database Sicada. For 28 of these combinations of pumping and injection section, estimates of hydraulic diffusivity and apparent storativity from hydraulic interference tests were also found. An empirical relationship between mass balance aperture and transmissivity was estimated, although some uncertainties for individual data exist. The empirical relationship between mass balance aperture and transmissivity presented in this study deviates considerably from other previously suggested relationships, such as the cubic law and transport aperture as suggested by /Dershowitz and Klise 2002/, /Dershowitz et al. 2002/ and /Dershowitz et al. 2003/, which also is discussed in this report. No clear and direct empirical relationship between mass balance aperture and hydraulic

  5. Tracer Testing for Estimating Heat Transfer Area in Fractured Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, Karsten; van Heel, Ton; Shan, Chao

    2004-05-12

    A key parameter governing the performance and life-time of a Hot Fractured Rock (HFR) reservoir is the effective heat transfer area between the fracture network and the matrix rock. We report on numerical modeling studies into the feasibility of using tracer tests for estimating heat transfer area. More specifically, we discuss simulation results of a new HFR characterization method which uses surface-sorbing tracers for which the adsorbed tracer mass is proportional to the fracture surface area per unit volume. Sorption in the rock matrix is treated with the conventional formulation in which tracer adsorption is volume-based. A slug of solute tracer migrating along a fracture is subject to diffusion across the fracture walls into the adjacent rock matrix. Such diffusion removes some of the tracer from the fluid in the fractures, reducing and retarding the peak in the breakthrough curve (BTC) of the tracer. After the slug has passed the concentration gradient reverses, causing back-diffusion from the rock matrix into the fracture, and giving rise to a long tail in the BTC of the solute. These effects become stronger for larger fracture-matrix interface area, potentially providing a means for estimating this area. Previous field tests and modeling studies have demonstrated characteristic tailing in BTCs for volatile tracers in vapor-dominated reservoirs. Simulated BTCs for solute tracers in single-phase liquid systems show much weaker tails, as would be expected because diffusivities are much smaller in the aqueous than in the gas phase, by a factor of order 1000. A much stronger signal of fracture-matrix interaction can be obtained when sorbing tracers are used. We have performed simulation studies of surface-sorbing tracers by implementing a model in which the adsorbed tracer mass is assumed proportional to the fracture-matrix surface area per unit volume. The results show that sorbing tracers generate stronger tails in BTCs, corresponding to an effective

  6. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lattin, Rebecca Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable

  7. The ATLAS DDM Tracer monitoring framework

    CERN Document Server

    ZANG, D; The ATLAS collaboration; BARISITS, M; LASSNIG, M; Andrew STEWART, G; MOLFETAS, A; BEERMANN, T

    2012-01-01

    The DDM Tracer Service is aimed to trace and monitor the atlas file operations on the Worldwide LHC Computing Grid. The volume of traces has increased significantly since the service started in 2009. Now there are about ~5 million trace messages every day and peaks of greater than 250Hz, with peak rates continuing to climb, which gives the current service structure a big challenge. Analysis of large datasets based on on-demand queries to the relational database management system (RDBMS), i.e. Oracle, can be problematic, and have a significant effect on the database's performance. Consequently, We have investigated some new high availability technologies like messaging infrastructure, specifically ActiveMQ, and key-value stores. The advantages of key value store technology are that they are distributed and have high scalability; also their write performances are usually much better than RDBMS, all of which are very useful for the Tracer service. Indexes and distributed counters have been also tested to improve...

  8. Advection and dispersion of bed load tracers

    Science.gov (United States)

    Lajeunesse, Eric; Devauchelle, Olivier; James, François

    2018-05-01

    We use the erosion-deposition model introduced by Charru et al. (2004) to numerically simulate the evolution of a plume of bed load tracers entrained by a steady flow. In this model, the propagation of the plume results from the stochastic exchange of particles between the bed and the bed load layer. We find a transition between two asymptotic regimes. The tracers, initially at rest, are gradually set into motion by the flow. During this entrainment regime, the plume is strongly skewed in the direction of propagation and continuously accelerates while spreading nonlinearly. With time, the skewness of the plume eventually reaches a maximum value before decreasing. This marks the transition to an advection-diffusion regime in which the plume becomes increasingly symmetrical, spreads linearly, and advances at constant velocity. We analytically derive the expressions of the position, the variance, and the skewness of the plume and investigate their asymptotic regimes. Our model assumes steady state. In the field, however, bed load transport is intermittent. We show that the asymptotic regimes become insensitive to this intermittency when expressed in terms of the distance traveled by the plume. If this finding applies to the field, it might provide an estimate for the average bed load transport rate.

  9. Plant mutation breeding and application of isotopic tracer in Chinese agriculture

    International Nuclear Information System (INIS)

    Liang Qu

    1993-03-01

    The progress and achievements made in plant mutation breeding and application of isotopic tracer in Chinese agriculture are outlined. Plant mutation breeding is well developed not only in improvement of crops but also in methodology of mutation induction. More than 325 mutant varieties and hundreds of various valuable mutants of 29 different species have been obtained. The mutant cultivars released have covered more than 10 million hectares in total area. The systematic studies on methodology such as techniques for mutagenic treatment, development of various mutagens, screening and selecting techniques of mutation etc. have been carried out in China. The techniques of radioisotopic tracer used in many research fields are described. Application of isotopic tracer in studies of fertilization and plant nutrition, environment protection, nitrogen-fixation, animal production and diagnosis of diseases, and so on, have made great achievements and benefits in China. Many kinds of labelled compounds, especially of labelled agro-chemicals have been synthesized in the Institute for Application of Atomic Energy (IAAE). Chinese Academy of Agricultural Sciences (CAAS). The proposals for the region cooperation in Asia on application of atomic energy in agriculture are included

  10. The constant rate injection tracer method - principle and application of a useful system for the investigation of single- and two-phase flows in thermal power plants

    International Nuclear Information System (INIS)

    Ederhof, A.; Lindberg, G.

    1985-01-01

    The ''tracer technique'', developed by Brown, Boveri and Company, permits measurement of water (liquid) mass flows, as part of the requested steam wetness, in steam turbine cycles. The additionally required steam mass flows can be calculated from mass flow balances (e.g. after condensation in a heater and subsequent measuring of the condensate flow) or energy balances. This measuring method is basically a dilution measurement using a radioactive or inactive tracer. If the radionuclide 24 Na is used, the measuring uncertainties will be typically 0.5-1.0%. The tracer technique was developed for largely automated parallel measurements on up to 30 lines of large capacity steam turbines. The example of the Ringhals 3 nuclear power plant illustrates that the tracer measuring method, applied during an acceptance test, yields better information on the functioning of the turbine cycle. (orig./GL) [de

  11. Heat as a tracer to determine streambed water exchanges

    Science.gov (United States)

    Constantz, J.

    2010-01-01

    This work reviews the use of heat as a tracer of shallow groundwater movement and describes current temperature-based approaches for estimating streambed water exchanges. Four common hydrologic conditions in stream channels are graphically depicted with the expected underlying streambed thermal responses, and techniques are discussed for installing and monitoring temperature and stage equipment for a range of hydrological environments. These techniques are divided into direct-measurement techniques in streams and streambeds, groundwater techniques relying on traditional observation wells, and remote sensing and other large-scale advanced temperatureacquisition techniques. A review of relevant literature suggests researchers often graphically visualize temperature data to enhance conceptual models of heat and water flow in the near-stream environment and to determine site-specific approaches of data analysis. Common visualizations of stream and streambed temperature patterns include thermographs, temperature envelopes, and one-, two-, and three-dimensional temperature contour plots. Heat and water transport governing equations are presented for the case of transport in streambeds, followed by methods of streambed data analysis, including simple heat-pulse arrival time and heat-loss procedures, analytical and time series solutions, and heat and water transport simulation models. A series of applications of these methods are presented for a variety of stream settings ranging from arid to continental climates. Progressive successes to quantify both streambed fluxes and the spatial extent of streambeds indicate heat-tracing tools help define the streambed as a spatially distinct field (analogous to soil science), rather than simply the lower boundary in stream research or an amorphous zone beneath the stream channel.

  12. Oxygen tracer diffusion and surface exchange kinetics in Ba0.5Sr0.5Co0.8Fe0.2O3-δ

    NARCIS (Netherlands)

    Berenov, A.; Atkinson, A.; Kilner, J.; Ananyev, M.; Eremin, V.; Porotnikova, N.; Farlenkov, A.; Kurumchin, E.; Bouwmeester, Henricus J.M.; Bucher, E.; Sitte, W.

    2014-01-01

    The oxygen tracer diffusion coefficient, Db⁎, and the oxygen tracer surface exchange coefficient, k, were measured in Ba0.5Sr0.5Co0.8Fe0.2O3 − δ (BSCF5582) over the temperature range of 310–800 °C and the oxygen partial pressure range of 1.3 × 10−3–0.21 bar. Several measurement techniques were used:

  13. Using radioactive tracers for the evaluation of industrial equipment; Utilizacao de tracadores radioativos na avaliacao de equipamentos industriais

    Energy Technology Data Exchange (ETDEWEB)

    Brandao, Luis Eduardo Barreira; Sa, Lidia Vasconcellos de; Sousa, Alvaro Serafim F. de [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2000-07-01

    This paper presents the radioactive tracer technique, giving as example some cases of the possible utilization developed by the Nuclear Engineering Institute, RJ, BR (Argonaut reactor) and through charged particle (CV-28 cyclotron), and also his production and aspects of radiological safety.

  14. A dual tracer ratio method for comparative emission measurements in an experimental dairy housing

    Science.gov (United States)

    Mohn, Joachim; Zeyer, Kerstin; Keck, Margret; Keller, Markus; Zähner, Michael; Poteko, Jernej; Emmenegger, Lukas; Schrade, Sabine

    2018-04-01

    Agriculture, and in particular dairy farming, is an important source of ammonia (NH3) and non-carbon dioxide greenhouse gas (GHG) emissions. This calls for the development and quantification of effective mitigation strategies. Our study presents the implementation of a dual tracer ratio method in a novel experimental dairy housing with two identical, but spatially separated housing areas. Modular design and flexible floor elements allow the assessment of structural, process engineering and organisational abatement measures at practical scale. Thereby, the emission reduction potential of specific abatement measures can be quantified in relation to a reference system. Emissions in the naturally ventilated housing are determined by continuous dosing of two artificial tracers (sulphur hexafluoride SF6, trifluoromethylsulphur pentafluoride SF5CF3) and their real-time detection in the ppt range with an optimized GC-ECD method. The two tracers are dosed into different experimental sections, which enables the independent assessment of both housing areas. Mass flow emissions of NH3 and GHGs are quantified by areal dosing of tracer gases and multipoint sampling as well as real-time analysis of both tracer and target gases. Validation experiments demonstrate that the technique is suitable for both areal and point emission sources and achieves an uncertainty of less than 10% for the mass emissions of NH3, methane (CH4) and carbon dioxide (CO2), which is superior to other currently available methods. Comparative emission measurements in this experimental dairy housing will provide reliable, currently unavailable information on emissions for Swiss dairy farming and demonstrate the reduction potential of mitigation measures for NH3, GHGs and potentially other pollutants.

  15. Simultaneous extraction and concentration of water pollution tracers using ionic-liquid-based systems.

    Science.gov (United States)

    Dinis, Teresa B V; Passos, Helena; Lima, Diana L D; Sousa, Ana C A; Coutinho, João A P; Esteves, Valdemar I; Freire, Mara G

    2017-07-29

    Human activities are responsible for the release of innumerous substances into the aquatic environment. Some of these substances can be used as pollution tracers to identify contamination sources and to prioritize monitoring and remediation actions. Thus, their identification and quantification are of high priority. However, due to their presence in complex matrices and at significantly low concentrations, a pre-treatment/concentration step is always required. As an alternative to the currently used pre-treatment methods, mainly based on solid-phase extractions, aqueous biphasic systems (ABS) composed of ionic liquids (ILs) and K 3 C 6 H 5 O 7 are here proposed for the simultaneous extraction and concentration of mixtures of two important pollution tracers, caffeine (CAF) and carbamazepine (CBZ). An initial screening of the IL chemical structure was carried out, with extraction efficiencies of both tracers to the IL-rich phase ranging between 95 and 100%, obtained in a single-step. These systems were then optimized in order to simultaneously concentrate CAF and CBZ from water samples followed by HPLC-UV analysis, for which no interferences of the ABS phase-forming components and other interferents present in a wastewater effluent sample have been found. Based on the saturation solubility data of both pollution tracers in the IL-rich phase, the maximum estimated concentration factors of CAF and CBZ are 28595- and 8259-fold. IL-based ABS can be thus envisioned as effective pre-treatment techniques of environmentally-related aqueous samples for a more accurate monitoring of mixtures of pollution tracers. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Measuring serotonin synthesis: from conventional methods to PET tracers and their (pre)clinical implications

    Energy Technology Data Exchange (ETDEWEB)

    Visser, Anniek K.D.; Waarde, Aren van; Willemsen, Antoon T.M. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Bosker, Fokko J. [University of Groningen, University Medical Center Groningen, University Center of Psychiatry, Groningen (Netherlands); Luiten, Paul G.M. [University of Groningen, Center for Behavior and Neurosciences, Department of Molecular Neurobiology, Haren (Netherlands); Boer, Johan A. den [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, University Center of Psychiatry, Groningen (Netherlands); Kema, Ido P. [University of Groningen, University Medical Center Groningen, Department of Laboratory Medicine, Groningen (Netherlands); Dierckx, Rudi A.J.O. [University of Groningen, University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Hospital Ghent, Department of Nuclear Medicine, Ghent (Belgium)

    2011-03-15

    The serotonergic system of the brain is complex, with an extensive innervation pattern covering all brain regions and endowed with at least 15 different receptors (each with their particular distribution patterns), specific reuptake mechanisms and synthetic processes. Many aspects of the functioning of the serotonergic system are still unclear, partially because of the difficulty of measuring physiological processes in the living brain. In this review we give an overview of the conventional methods of measuring serotonin synthesis and methods using positron emission tomography (PET) tracers, more specifically with respect to serotonergic function in affective disorders. Conventional methods are invasive and do not directly measure synthesis rates. Although they may give insight into turnover rates, a more direct measurement may be preferred. PET is a noninvasive technique which can trace metabolic processes, like serotonin synthesis. Tracers developed for this purpose are {alpha}-[{sup 11}C]methyltryptophan ([{sup 11}C]AMT) and 5-hydroxy-L-[{beta}-{sup 11}C]tryptophan ([{sup 11}C]5-HTP). Both tracers have advantages and disadvantages. [{sup 11}C]AMT can enter the kynurenine pathway under inflammatory conditions (and thus provide a false signal), but this tracer has been used in many studies leading to novel insights regarding antidepressant action. [{sup 11}C]5-HTP is difficult to produce, but trapping of this compound may better represent serotonin synthesis. AMT and 5-HTP kinetics are differently affected by tryptophan depletion and changes of mood. This may indicate that both tracers are associated with different enzymatic processes. In conclusion, PET with radiolabelled substrates for the serotonergic pathway is the only direct way to detect changes of serotonin synthesis in the living brain. (orig.)

  17. TMI cable tracer operation and maintenance manual for assembly 417910

    International Nuclear Information System (INIS)

    Sumstine, R.L.

    1983-11-01

    This manual provides technical information and instructions to operate and maintain the cable tracer designed for the Three Mile Island (TMI) Unit 2 Reactor Building. The TMI cable tracer was developed to allow TMI personnel to trace cables in cable trays that may be tested or sectioned for destructive examination

  18. Methane emission quantification from landfills using a double tracer approach

    DEFF Research Database (Denmark)

    Scheutz, Charlotte; Samuelsson, J.; Fredenslund, Anders Michael

    2007-01-01

    A tracer method was successfully used for quantification of the whole methane (CH4) emission from Fakse landfill. By using two different tracers the emission from different sections of the landfill could be quantified. Furthermore, is was possible to determine the emissions from local on site...

  19. Toxicity of fluorescent tracers and their degradation byproducts

    Directory of Open Access Journals (Sweden)

    Philippe Gombert

    2017-01-01

    Full Text Available Tracer tests are frequently used to delineate catchment area of water supply springs in karstic zones. In the karstic chalk of Normandy, the main tracers used are fluorescent: uranine, sulforhodamine B, naphtionate, and Tinopal®. In this area, a statistical analysis shows that less than half of the injected tracers joins the monitored restitution points and enters the drinking water system where they undergo chlorination. Most of the injected tracers is absorbed in the rock matrix or is thrown out of the aquifer via karstic springs: then it can join superficial waters where it is degraded due to the sun and air action. The paper presents firstly the laboratory degradation of a first batch of fluorescent tracers in contact with chlorine, in order to simulate their passage through a water treatment system for human consumption. A second batch of the same tracers is subjected to agents of natural degradation: ultraviolet illumination, sunlight and air sparging. Most tracers is degraded, and toxicity and ecotoxicity tests (on rats, daphniae and algae are performed on degradation byproducts. These tests do not show any acute toxicity but a low to moderate ecotoxicity. In conclusion, the most used fluorescent tracers of the Normandy karstic chalk and their artificial and natural degradation byproducts do not exhibit significant toxicity to humans and the aquatic environment, at the concentrations generally noted at the restitution points.

  20. Kinetic analysis of 18F-fluorodihydrorotenone as a deposited myocardial flow tracer: Comparison to thallium-201.

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, Robert C.; Powers-Risius, Patricia; Reutter, Bryan W.; O' Neil, James P.; La Belle, Michael; Huesman, Ronald H.; VanBrocklin, Henry F.

    2004-03-01

    The goal of this investigation was to assess the accuracy of 18F-fluorodihydrorotenone (18F-FDHR) as a new deposited myocardial flow tracer and compare the results to those for 201Tl. Methods. The kinetics of these flow tracers were evaluated in 22 isolated, erythrocyte- and albumin-perfused rabbit hearts over a flow range encountered in patients. The two flow tracers plus a vascular reference tracer (131I-albumin) were introduced as a bolus through a port just above the aortic cannula. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves using the multiple indicator dilution technique and spectral analysis. Results. The mean initial extraction fractions of 18F-FDHR (0.85 +- 0.07) and 201Tl (0.87 +- 0.05) were not significantly different, although the initial extraction fraction for 18F-FDHR declined with flow (P < 0.0001), whereas the initial extraction fraction of 201Tl did not. Washout of 201Tl was faster (P < 0.001) and more affected by flow (P < 0.05) than 18F-FDHR washout. Except for initial extraction fraction, 18F-FDHR retention was greater (P < 0.001) and less affected by flow (P < 0.05) than 201Tl retention. Reflecting its superior retention, net uptake of 18F-FDHR was better correlated with flow than 201Tl uptake at both one and fifteen minutes after tracer introduction (P < 0.0001 for both comparisons). Conclusion. The superior correlation of 18F-FDHR uptake with flow indicates that it is a better flow tracer than 201Tl in the isolated rabbit heart. Compared to the other currently available positron-emitting flow tracers (82Rb, 13N-ammonia, and 15O-water), 18F-FDHR has the potential of providing excellent image resolution without the need for an on-site cyclotron.

  1. National Biomedical Tracer Facility. Project definition study

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, R.

    1995-02-14

    We request a $25 million government-guaranteed, interest-free loan to be repaid over a 30-year period for construction and initial operations of a cyclotron-based National Biomedical Tracer Facility (NBTF) in North Central Texas. The NBTF will be co-located with a linear accelerator-based commercial radioisotope production facility, funded by the private sector at approximately $28 million. In addition, research radioisotope production by the NBTF will be coordinated through an association with an existing U.S. nuclear reactor center that will produce research and commercial radioisotopes through neutron reactions. The combined facilities will provide the full range of technology for radioisotope production and research: fast neutrons, thermal neutrons, and particle beams (H{sup -}, H{sup +}, and D{sup +}). The proposed NBTF facility includes an 80 MeV, 1 mA H{sup -} cyclotron that will produce proton-induced (neutron deficient) research isotopes.

  2. Use of radioactive tracers in chemical reactions

    International Nuclear Information System (INIS)

    Paci, B.; Saiki, M.

    1979-01-01

    A method for the determination of small quantities of nickel by using radioactive tracers is presented. An analytical application of the displacement reaction between and zinc-ethylenediaminetetraacetate, (Zn-EDTA), labelled with 65 Zn is investigated. This method is based on the extraction of radioactive zinc, displaced by nickel from the zinc chelate, into a dithizone-carbon tetrachloride solution and the subsequent measurement of the activity of an aliquot of the extract. It is shown that the method is very sentitive and nickel can be measured in concentrations as small as 0,1μg/ml or even less, depending on the specific activity of the radioreagent used. The precision and accuracy of the method are determined. An attempt to eliminate the problem of interference by using masking agents or by means of a previous separation of nickel and other interfereing metals, is also made. (Author) [pt

  3. Positron emission tomography tracers for imaging angiogenesis

    International Nuclear Information System (INIS)

    Haubner, Roland; Beer, Ambros J.; Wang, Hui; Chen, Xiaoyuan

    2010-01-01

    Position emission tomography imaging of angiogenesis may provide non-invasive insights into the corresponding molecular processes and may be applied for individualized treatment planning of antiangiogenic therapies. At the moment, most strategies are focusing on the development of radiolabelled proteins and antibody formats targeting VEGF and its receptor or the ED-B domain of a fibronectin isoform as well as radiolabelled matrix metalloproteinase inhibitors or α v β 3 integrin antagonists. Great efforts are being made to develop suitable tracers for different target structures. All of the major strategies focusing on the development of radiolabelled compounds for use with positron emission tomography are summarized in this review. However, because the most intensive work is concentrated on the development of radiolabelled RGD peptides for imaging α v β 3 expression, which has successfully made its way from bench to bedside, these developments are especially emphasized. (orig.)

  4. Atmospheric tracer experiments for regional dispersion studies

    International Nuclear Information System (INIS)

    Heffter, J.L.; Ferber, G.J.

    1980-01-01

    Tracer experiments are being conducted to verify atmospheric transport and dispersion calculations at distances from tens to hundreds of km from pollutant sources. In one study, a 2 1/2 year sampling program has been carried out at 13 sites located 30 to 140 km from a source of 85 Kr at the Savannah River Plant in South Carolina. Average weekly concentrations as well as twice-daily concentrations were obtained. Sampling data and meteorological data, including surface, tower, and rawinsonde observations are available on magnetic tape for model verification studies. Some verification results for the Air Resources Laboratories Atmospheric Transort and Dispersion Model (ARL-ATAD) are shown for averaging periods from one week to two years

  5. Use of radioactive tracers in chemical reactions

    International Nuclear Information System (INIS)

    Paci, B.

    1979-01-01

    A method for the determination of small quantities of nickel using radioactive tracers is presented. An analytical application of the displacement reaction between nickel and zinc ethylenediaminetetraacetate labeled with zinc-65 is pursued. This method is based on the extraction of radioactive zinc displaced by nickel from the zinc chelate into a dithizone-carbon tetracloride solution and the subsequent measurement of the activity of an aliquot of the extract. The method is very sensitive and nickel can be measured in concentrations as small as 0.1μg/ml or even less, depending on the specific activity of the radioreagent used. The precision and the accuracy of the method are determined. The problem of interferences, trying to eliminate them by using masking agents or by means of a previous separation between nickel and other interfering metals, is also investigated [pt

  6. National Biomedical Tracer Facility. Project definition study

    International Nuclear Information System (INIS)

    Schafer, R.

    1995-01-01

    We request a $25 million government-guaranteed, interest-free loan to be repaid over a 30-year period for construction and initial operations of a cyclotron-based National Biomedical Tracer Facility (NBTF) in North Central Texas. The NBTF will be co-located with a linear accelerator-based commercial radioisotope production facility, funded by the private sector at approximately $28 million. In addition, research radioisotope production by the NBTF will be coordinated through an association with an existing U.S. nuclear reactor center that will produce research and commercial radioisotopes through neutron reactions. The combined facilities will provide the full range of technology for radioisotope production and research: fast neutrons, thermal neutrons, and particle beams (H - , H + , and D + ). The proposed NBTF facility includes an 80 MeV, 1 mA H - cyclotron that will produce proton-induced (neutron deficient) research isotopes

  7. Molecular dynamics investigation of tracer diffusion in a simple liquid

    International Nuclear Information System (INIS)

    Ould-Kaddour, F.; Barrat, J.L.

    1991-05-01

    Extensive Molecular-Dynamics (MD) simulations have been carried out for a model trace-solvent system made up of 100 solvent molecules and 8 tracer molecules interacting through truncated Lennard-Jones potentials. The influence of the size ratio between solute and solvent, of their mass ratio and of the solvent viscosity on the diffusivity of a small tracer were investigated. Positive deviations from a Stokes-Einstein behaviour are observed, in qualitative agreement with experimental observations. It was also observed that as tracer and solvent become increasingly dissimilar, their respective dynamics becomes decoupled. We suggest that such decouplings can be interpreted by writing their mobility of the tracer as the sum of two terms, the first one arising from a coupling between tracer dynamics and hydrodynamics modes of the solvent, and the second one describing jump motion in a locally nearly frozen environment. (author). 17 refs, 4 figs, 6 tabs

  8. Benefits of important industrial tracer applications in the GDR

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Goeldner, R.; Koennecke, H.G.; Kupsch, H.; Luther, D.; Otto, R.; Reinhardt, R.; Ulrich, H.

    1990-01-01

    Tracers can be used to label substances or objects in order to discriminate between them, to follow their movement, to record changes of concentration and distribution between phases, etc. The main advantages of tracer investigations are the contactless recording of signals without influencing the observed process (also under rigorous operation conditions), the high detection sensitivity, the large number of available tracer nuclides (problems of all branches of industry can be solved) and the fact that tracer investigation can be carried out on operating production units, so that they provide valuable checks of the validity of design and process data. The cost-to-benefit ratio can be as low as 1:50. In the following some selected examples of tracer applications and their benefits will be presented. (orig./BBR) [de

  9. 3-D migration experiment - report 2: Instrumentation and tracers

    International Nuclear Information System (INIS)

    Abelin, H.; Birgersson, L.; Gidlund, J.

    1987-11-01

    This report is one of the four reports describing the Stripa 3D experiment where water and tracer flow has been monitored in a specially excavated drift in the Stripa mine. The experiment was performed in a specially excavated drift at the 360 m level in granite. The whole ceiling and upper part of the walls were covered with more than 350 individual plastic sheets where the water flow into the drift could be collected. 11 different tracers were injected at distances between 11 and 50 m from the ceiling of the drift. The flow rate and tracer monitoring was kept up for more than two years. The tracer breakthrough curves and flow rate distributions were used to study the flow paths, velocities, hydraulic conductivities, dispersivities and channeling effects in the rock. The report describes the instrumentation developed and used as well as the tracers that were tested and used in the experiment. (orig.)

  10. Economics on nuclear techniques application in industry

    International Nuclear Information System (INIS)

    Kato, Masao

    1979-01-01

    The economics of the application of nuclear techniques to industry is discussed. Nuclear techniques were applied to gauging (physical measurement), analysis, a radioactive tracer method, electrolytic dissociation, and radiography and were found to be very economical. They can be applied to manufacturing, mining, oceano-engineering, environmental engineering, and construction, all of which have a great influence on economics. However, because the application of a radioactive tracer technique does not have a direct influence on economics, it is difficult to estimate how beneficial it is. The cost-benefit ratio method recommended by IAEA was used for economical calculations. Examples of calculations made in gauging and analysis are given. (Ueda, J.)

  11. Strontium isotopes as natural tracers in reservoir oilfield and in groundwater systems

    International Nuclear Information System (INIS)

    Santos, Marcos E.; Palmieri, Helena E.L.; Moreira, Rubens M.

    2009-01-01

    The radioactive beta (β - ) decay of 87 Rb to 87 Sr is an important isotope system that has been widely applied for geochronological purposes and in identifying ground water sources, aquifer interactions and as a tracer for a secondary recovery process in offshore oilfields via seawater injection. The 87 Sr/ 86 Sr ratio of present seawater is constant worldwide, while formation waters in hydrocarbon reservoirs have various values are in most cases higher than modern seawater. This can be the basis for a natural tracer technique aiming at evaluating the performance of seawater injection processes by evaluating the 87 Sr/ 86 Sr ratio and the total Sr content of formation waters in the reservoir prior to injection, followed by monitoring these values in the produced water as injection proceeds. Inductively Couple Plasma Mass Spectrometry ICP-MS is a technique that has potential to be used in studies with tracers in the environment in the determination of isotope ratios and element traces in a sample. This work describes the methodology that will be used for the determination of variations in the isotopic composition of Sr and presents the preliminary results obtained determination of the strontium isotope ratios ( 87 Sr/ 86 Sr) using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). (author)

  12. Mineral imbalances in farm animals and their study and diagnosis with isotopic tracers

    International Nuclear Information System (INIS)

    Underwood, E.J.

    1976-01-01

    Twenty-two mineral elements are known to be essential for animal life. These are calcium, phosphorus, sulphur, potassium, sodium, chlorine, magnesium, iron, iodine, copper, manganese, zinc, cobalt, molybdenum, selenium, chromium, tin, vanadium, fluorine, silicon, nickel and arsenic. Naturally occurring and man-made dietary imbalances of many of these elements and their interactions with other minerals are described and their functions and requirements by farm animals are outlined. The nature and importance of metabolic interactions among the mineral elements are discussed and the important concept stressed that there is no single minimum requirement or safe tolerance of a particular mineral, but a series of such minimum requirements and safe tolerances depending on the extent to which other minerals with which it interacts is present or absent from the diet. Radioactive tracer elements are shown to be of great value in the determination of mineral nutrient availability to the animal and for following mineral metabolic movements in the body. They are also shown to have considerable potential for the diagnosis of mineral imbalances. Various in vivo and in vitro techniques involving both radioactive and stable tracers developed for the early diagnosis of mineral deficiencies are described and the strengths and weaknesses of such techniques, in comparison with standard biochemical tests, are discussed. The need for further critical studies with isotopic tracers in the detection and diagnosis of mineral imbalances is emphasized. The main types of biochemical criteria used in the diagnosis of mineral deficiencies and excesses are given, with appropriate examples of their use. (author)

  13. Positron emission tomography with additional γ-ray detectors for multiple-tracer imaging.

    Science.gov (United States)

    Fukuchi, Tomonori; Okauchi, Takashi; Shigeta, Mika; Yamamoto, Seiichi; Watanabe, Yasuyoshi; Enomoto, Shuichi

    2017-06-01

    Positron emission tomography (PET) is a useful imaging modality that quantifies the physiological distributions of radiolabeled tracers in vivo in humans and animals. However, this technique is unsuitable for multiple-tracer imaging because the annihilation photons used for PET imaging have a fixed energy regardless of the selection of the radionuclide tracer. This study developed a multi-isotope PET (MI-PET) system and evaluated its imaging performance. Our MI-PET system is composed of a PET system and additional γ-ray detectors. The PET system consists of pixelized gadolinium orthosilicate (GSO) scintillation detectors and has a ring geometry that is 95 mm in diameter with an axial field of view of 37.5 mm. The additional detectors are eight bismuth germanium oxide (BGO) scintillation detectors, each of which is 50 × 50 × 30 mm 3 , arranged into two rings mounted on each side of the PET ring with a 92-mm-inner diameter. This system can distinguish between different tracers using the additional γ-ray detectors to observe prompt γ-rays, which are emitted after positron emission and have an energy intrinsic to each radionuclide. Our system can simultaneously acquire double- (two annihilation photons) and triple- (two annihilation photons and a prompt γ-ray) coincidence events. The system's efficiency for detecting prompt de-excitation γ-rays was measured using a positron-γ emitter, 22 Na. Dual-radionuclide ( 18 F and 22 Na) imaging of a rod phantom and a mouse was performed to demonstrate the performance of the developed system. Our system's basic performance was evaluated by reconstructing two images, one containing both tracers and the other containing just the second tracer, from list-mode data sets that were categorized by the presence or absence of the prompt γ-ray. The maximum detection efficiency for 1275 keV γ-rays emitted from 22 Na was approximately 7% at the scanner's center, and the minimum detection efficiency was 5.1% at the edge of

  14. A novel fluorescent retrograde neural tracer: cholera toxin B conjugated carbon dots

    Science.gov (United States)

    Zhou, Nan; Hao, Zeyu; Zhao, Xiaohuan; Maharjan, Suraj; Zhu, Shoujun; Song, Yubin; Yang, Bai; Lu, Laijin

    2015-09-01

    The retrograde neuroanatomical tracing method is a key technique to study the complex interconnections of the nervous system. Traditional tracers have several drawbacks, including time-consuming immunohistochemical or immunofluorescent staining procedures, rapid fluorescence quenching and low fluorescence intensity. Carbon dots (CDs) have been widely used as a fluorescent bio-probe due to their ultrasmall size, excellent optical properties, chemical stability, biocompatibility and low toxicity. Herein, we develop a novel fluorescent neural tracer: cholera toxin B-carbon dot conjugates (CTB-CDs). It can be taken up and retrogradely transported by neurons in the peripheral nervous system of rats. Our results show that CTB-CDs possess high photoluminescence intensity, good optical stability, a long shelf-life and non-toxicity. Tracing with CTB-CDs is a direct and more economical way of performing retrograde labelling experiments. Therefore, CTB-CDs are reliable fluorescent retrograde tracers.The retrograde neuroanatomical tracing method is a key technique to study the complex interconnections of the nervous system. Traditional tracers have several drawbacks, including time-consuming immunohistochemical or immunofluorescent staining procedures, rapid fluorescence quenching and low fluorescence intensity. Carbon dots (CDs) have been widely used as a fluorescent bio-probe due to their ultrasmall size, excellent optical properties, chemical stability, biocompatibility and low toxicity. Herein, we develop a novel fluorescent neural tracer: cholera toxin B-carbon dot conjugates (CTB-CDs). It can be taken up and retrogradely transported by neurons in the peripheral nervous system of rats. Our results show that CTB-CDs possess high photoluminescence intensity, good optical stability, a long shelf-life and non-toxicity. Tracing with CTB-CDs is a direct and more economical way of performing retrograde labelling experiments. Therefore, CTB-CDs are reliable fluorescent retrograde

  15. Tracer migration experiments in the Stripa mine 1980-1991

    International Nuclear Information System (INIS)

    Birgersson, L.; Widen, H.; Aagren, T.; Neretnieks, I.

    1992-05-01

    During more than 10 years, tracer experiments have been performed in the Stripa mine as part of the Stripa project to investigate the properties of both 'average' fractured rock and fracture zones. Experiments have been performed that have ranged from a few decimeters, to examine the diffusion into the rock matrix, up to tracer migration to a drift more than 50 meters from the injection point. This report compiles the results and experience that have been gained from all these tracer experiments. The experiments that are described in this report are: * The in-situ diffusion experiment where simultaneous flow and diffusion of tracers in undisturbed rock were studied over more than 3 years to validate diffusivities obtained under laboratory conditions. * Migration in a single fracture where water flow distribution and tracer transport were studied using both conservative and sorbing tracers over migration distances up to 10 meters. * The 3-D migration experiment where water inflow and tracer transport to a drift covered with 350 plastic sheet were investigated to get information on flow porosity, dispersion and channeling. The transport distances were between 10 and 56 meters from the injection points to the drift. * The channeling experiments in which the aim was to examine the channeling properties of single fractures in detail. Pressure pulse tests and tracer experiments were performed over a distances of 2 meters. * The tracer migration experiment in the validation drift where the tracer were injected mainly in a fracture zone and the collection was inside both a drift covered with plastic sheets similar to in the 3-D experiment as well as in a borehole. The distances between injection and sampling location were between 10 and 25 meters. (57 refs.) (au)

  16. Methods and systems using encapsulated tracers and chemicals for reservoir interrogation and manipulation

    Science.gov (United States)

    Roberts, Jeffery; Aines, Roger D; Duoss, Eric B; Spadaccini, Christopher M

    2014-11-04

    An apparatus, method, and system of reservoir interrogation. A tracer is encapsulating in a receptacle. The receptacle containing the tracer is injected into the reservoir. The tracer is analyzed for reservoir interrogation.

  17. Perdurabilidad empresarial: concepto, estudios, hallazgos

    Directory of Open Access Journals (Sweden)

    Hugo Alberto Rivera Rodríguez

    2012-06-01

    Full Text Available La literatura en dirección de empresas durante los últimos 20 años ha analizado diferentes aspectos de la perdurabilidad empresarial, sobre todo lo relacionado con el papel del líder, la asociación con la rentabilidad, y los efectos que genera en el tejido empresarial. Sin embargo, aún existen muchos aspectos en los cuales se debe profundizar. El primero de ellos es dar solución a la diversidad terminológica existente. Al no tener un consenso sobre el concepto, se utilizan de manera indiscriminada términos como longevidad, sostenibilidad, éxito, supervivencia, duración, etc., los cuales en lugar de aclarar, generan confusión. Por otro lado, tampoco hay evidencia suficiente para sugerir alternativas que permitan a las empresas lograr ser perdurables. El artículo que se presenta se fundamenta en una revisión exhaustiva del concepto de perdurabilidad empresarial, y hace una relación de los principales hallazgos encontrados en la literatura sobre las condiciones que pueden facilitar la perdurabilidad empresarial. Con ello se pretende de avanzar en el estudio de la relación entre la perdurabilidad, el comportamiento estratégico de las empresas y desempeño financiero.

  18. Brain regional uptake of radioactive Sc, Mn, Zn, Se, Rb and Zr tracers into normal mice during aging

    International Nuclear Information System (INIS)

    Amano, R.; Enomoto, S.

    2001-01-01

    Radioactive multitracer technique was applied to study the brain regional uptake of trace elements by the normal mice during aging. The brain regional radioactivities of 46 Sc, 54 Mn, 65 Zn, 75 Se, 83 Rb and 88 Zr were measured 48 hours after intraperitoneal injection of a solution in normal mice aged 6 to 52 weeks to evaluate the brain regional (corpus striatum, cerebellum, cerebral cortex, hippocampus, and pons and medulla) uptakes. The radioactive distributions of 46 Sc, 54 Mn and 88 Zr tracers were variable and region-specific in the brain, while those of 65 Zn, 75 Se and 83 Rb tracers were comparable among all regions of interest. The brain regional uptakes of all tracers slightly increased with age from 10 to 28 weeks, and then remained constant during aging after 28 weeks. These uptake variations may be involved in the functional degenerative process of the blood-brain barrier during aging. (author)

  19. Novel tracer for radiation treatment planning; Welche neuen PET-Tracer braucht die Strahlentherapie?

    Energy Technology Data Exchange (ETDEWEB)

    Schwarzenboeck, S.; Krause, B.J. [Rostock Univ. (Germany). Klinik fuer Nuklearmedizin; Herrmann, K.; Gaertner, F.; Souvatzoglou, M. [Technische Univ. Muenchen (Germany). Klinik fuer Nuklearmedizin; Klaesner, B. [Klinikum Bogenhausen, Muenchen (Germany). Inst. fuer Radiologie und Nuklearmedizin

    2011-07-15

    PET and PET/CT with innovative tracers gain increasing importance in diagnosis and therapy management, and radiation treatment planning in radio-oncology besides the widely established FDG. The introduction of [{sup 18}F]Fluorothymidine ([{sup 18}F]FLT) as marker of proliferation, [{sup 18}F]Fluoromisonidazole ([{sup 18}F]FMISO) and [{sup 18}F]Fluoroazomycin-Arabinoside ([{sup 18}F]FAZA) as tracer of hypoxia, [{sup 18}F]Fluoroethyltyrosine ([{sup 18}F]FET) and [{sup 11}C]Methionine for brain tumour imaging, [{sup 68}Ga]DOTATOC for somatostatin receptor imaging, [{sup 18}F]FDOPA for dopamine synthesis and radioactively labeled choline derivatives for imaging phospholipid metabolism have opened novel approaches to tumour imaging. Some of these tracers have already been implemented into radio-oncology: Amino acid PET and PET/CT have the potential to optimise radiation treatment planning of brain tumours through accurate delineation of tumour tissue from normal tissue, necrosis and edema. Hypoxia represents a major therapeutic problem in radiation therapy. Hypoxia imaging is very attractive as it may allow to increase the dose in hypoxic tumours potentially allowing for a better tumour control. Advances in hybrid imaging, i.e. the introduction of MR/PET, may also have an impact in radio-oncology through synergies related to the combination of molecular signals of PET and a high soft tissue contrast of MRI as well as functional MRI capabilities. (orig.)

  20. High-dilution on-stream isotopic tracer techniques; Emploi d'indicateurs radioactifs tres dilues pour le controle les courants; Metody primeneniya sil'no razbavlennykh v potokakh izotopnykh indikatorov; Empleo de indicadores radiactivos muy diluidos en el control de corrientes

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, W H; Findeis, A F; Vestal, M [William H . Johnston Laboratories, Inc., Baltimore, MD (United States)

    1962-01-15

    The present paper concerns large-scale tracer applications in which isotope tagging is done on a component of main flowing fluid or stream without subsequent mainline separation. Equations are derived which relate the required levels of tracer concentrations, the instrumental background, the efficiency of the detector, the required statistical reliability, the time desired for the measurements of sample and background, the stream flow rates, and the tracer nuclide. These equations are shown graphically and allow a ready selection of the tracer concentrations for specific applications. The sampling programme for large-scale tracer applications is analysed for steady state and pulse injections. In the latter case, the longitudinal mixing is treated by the concept of eddy diffusion coefficients. By estimating certain parameters, the longitudinal tracer detection range and the first arrival time are obtained as a function of distance between injection and collection. l'or high-dilution on-stream radiotracing with beta-emitters, the detectors are large low-level internal-gas-tube counters, foil-flow counters, and plastic scintillators. New anticoincidence counters are presented. The advantages of low-atomic-number shielding are emphasized. Recent developments in stable transistorized electronics for low-level counting are shown. A new amplifier and a new tunnel-diode adder circuit are described. Examples are given of several new applications of high-dilution on-stream tracers to problems of source-identification of pollutions in rivers and streams. (author) [French] Le memoire traite de l'emploi a grande echelle d'indicateurs pour le marquage isotopique des eaux d'un courant affluent qui ne se separe pas ensuite du courant principal. Les auteurs ont etabli des equations indiquant les rapports entre le taux de concentration des indicateurs, le bruit de fond du aux instruments, l'efficacite du detecteur, la qualite que l'on attend des donnees statistiques obtenues, le

  1. Seepage studies through hydraulic structures and their foundations by inactive and radio tracers

    International Nuclear Information System (INIS)

    Ansari, Azher; Mahajan, N.M.; Kamble, M.D.

    1977-01-01

    In the last ten years extensive efforts have been made by the Central Water and Power Research Station, Pune to study seepage by means of inactive and radiotracers. Various inactive tracers like electrolytes and organic dyes and radiotracers like 82 Br and 3 H in the form of tritiated water have been used for location of source of seepage. Different techniques like borehole dilution, in situ detection at various observation points and analysis of water samples in liquid scintillation spectrometer in the laboratory have been employed to suit the field conditions. Some typical studies at river valley projects indicating the techniques are enumerated. (author)

  2. Leak detection on underground fuel oil transfer line using radio tracer iodine-131

    International Nuclear Information System (INIS)

    Wickramanayake, D.G.L.; Ranjith, H.L.A.

    1998-01-01

    Leak detection study was carried out on the fuel oil transfer line of the Ceylon Petroleum Corporation using 131 I tracer. The study was carried out to determine whether the technique developed can be used in the field and to monitor the condition of the pipeline. Radiation safety assessment was made prior to the test. The dynamic pressurization technique was used. Any detectable leak was not shown at the detecting sensitivity of 0.40 mm 2 under the test conditions. The method reported is considered to be successful and economically viable. (author)

  3. Bromide as a tracer for studying water movement and nitrate displacement in soils: comparison with stable isotope tracers

    International Nuclear Information System (INIS)

    Russow, R.; Knappe, S.

    1999-01-01

    Tracers are an ideal means of studying water movement and associated nitrate displacement. Often bromide is preferred as a tracer because it is considered a representative tracer for water and because, being a conservative tracer (i.e. not involved in chemical and biological soil processes), it can be used for studying anion transport in soils. Moreover, it is less expensive and easier to measure than the stable isotopes deuterium and 15 N. Its great advantage over radioactive tracers (e.g. tritium), which outweighs their extreme sensitivity and ease of measurement and which it has in common with stable isotopes, is that it does not require radiation protection measures. However, there are also constraints on the use of bromide as a tracer in soil/water/plant systems. Our own studies on different soils using D 2 O, bromide and [ 15 N]-nitrate in lysimeters suggest that the above assumptions on bromide tracers need not always be valid under conditions as they prevail in biologically active soils. As the present paper shows, these studies permit a good assessment of the possibilities and limits to these tracers [de

  4. Measurement of radioactive tracer microsphere blood from with NaI(Tl)- and Ge-well type detectors

    International Nuclear Information System (INIS)

    Winkler, B.; Staemmler, G.; Schaper, W.; Frank, J.; Langsdorf, S.

    1982-01-01

    An intrinsic Ge-well type detector was applied for the detection of gamma rays from labeled tracer microspheres. The high energy resolution and the large peak-to-Compton ratio of this spectrometer ensures the application of all available differently labeled tracer microspheres in one experiment. The superior energy resolution of the Ge-detector was documented with the separated photopeak regions of 103-Ru and 85-Sr-labeled tracer microspheres, which result in a single photopeak when an NaI(Tl) detector is used. The Ge-well type detector was compared with an NaI(Tl) spectrometer by counting samples of cardiac muscle in either spectrometer systems. Regression analysis between both spectrometer systems demonstrate identical flow values in these samples for 5 differently labeled tracer microspheres which were administered in 5 dogs. The high sensitivity of the Ge-well-type detector together with a suitable technique for sampling of myocardial tissue accomplishes a high spatial resolution of myocardial perfusion for all available differently labeled tracer microspheres. (orig.)

  5. A radioactive tracer dilution method to determine the mass of molten salt

    International Nuclear Information System (INIS)

    Lei Cao; Jarrell, Josh; Hardtmayer, D.E.; White, Susan; Herminghuysen, Kevin; Kauffman, Andrew; Sanders, Jeff; Li, Shelly

    2017-01-01

    A new technique for molten salt mass determination, termed radioactive tracer dilution, that uses 22 Na as a tracer was validated at bench scale. It has been a challenging problem to determine the mass of molten salt in irregularly shaped containers, where a highly radioactive, high-temperature molten salt was used to process nuclear spent/used fuel during electrochemical recycling (pyro-processing) or for coolant/fuel salt from molten salt reactors. A radioactive source with known activity is dissolved into the salt. After a complete mixture, a small amount of the salt is sampled and measured in terms of its mass and radioactivity. By finding the ratio of the mass to radioactivity, the unknown salt mass in the original container can be precisely determined. (author)

  6. Runoff analysis by means of multiple isotope tracers in Iwami river drainage, Akita, Japan

    International Nuclear Information System (INIS)

    Matsubaya, Osamu; Yoshida, Minako; Tanaka-Miyamoto, Kiriko.

    1990-01-01

    By means of three isotope tracer techniques, proportion of direct runoff and characters of groundwater runoff were studied in the Iwami River drainage during a high runoff period for about 3 days, caused by a heavy rainfall of 85 mm for 17 hours. The proportion of direct runoff is 15 % or less of the total runoff caused by the rainfall, while 65 % of river water at the peak of runoff. Differences observed in the runoff manners among 18 O, 2 H, and 3 H are interpreted as a result of preferential runoff of previous precipitations stored in some unsaturated zone above the saturated groundwater zone. Cl - content is not conservative as a tracer to study runoff mechanisms. (author)

  7. Abordagem Exploratória do Emprego das Técnicas de Análise de Regressão e Análise Conjunta em Estudos do Comportamento do ConsumidorExploratory Approach to the use of Techniques of Regression Analysis and Pooled Analysis in Studies of Consumer BehaviorEstudio Exploratorio sobre la Utilización de Técnicas de Análisis de Regresión y de Análisis Conjunto en los Estudios del Comportamiento del Consumidor

    Directory of Open Access Journals (Sweden)

    GOUVÊA, Maria Aparecida

    2010-09-01

    Full Text Available RESUMOEste artigo faz parte de um amplo estudo de avaliação da adequação no uso de técnicas estatísticas multivariadas em teses e dissertações de algumas instituições de ensino superior na área de marketing na temática do comportamento do consumidor entre 1997 e 2006. Neste artigo são focalizadas as técnicas de análise de regressão e análise conjunta, duas técnicas com grande potencial de uso em estudos de marketing. Foi objetivo desse trabalho a análise da adequação do emprego destas técnicas às necessidades dos problemas de pesquisa apresentados nas teses e dissertações e a aferição do nível de acerto no atendimento de suas premissas. De forma geral, os resultados sugerem a necessidade de um aumento do comprometimento dos pesquisadores na verificação de todos os preceitos teóricos de aplicação destas técnicas classificadas na categoria de investigação de dependência entre variáveis.ABSTRACTThis paper is part of a large study to assess the adequacy of the use of multivariate statistical techniques in theses and dissertations of some higher education institutions in the area of marketing with theme of consumer behavior from 1997 to 2006. The regression and conjoint analysis are focused on in this paper, two techniques with great potential of use in marketing studies. The objective of this study was to analyze whether the employment of these techniques suits the needs of the research problem presented in as well as to evaluate the level of success in meeting their premisses. Overall, the results suggest the need for more involvement of researchers in the verification of all the theoretical precepts of application of the techniques classified in the category of investigation of dependence among variables.RESUMENEste artículo forma parte de un amplio estudio que evalúa la adecuación del uso de técnicas estadísticas multivariantes en las tesis y disertaciones de algunas instituciones de educación superior

  8. A Study Plan for Determining Recharge Rates at the Hanford Site Using Environmental Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, E. M.; Szecsody, J. E.; Phillips, S. J.

    1991-02-01

    . Seven study sites on the Hanford Site have been selected, in two primary soil types that are believed to represent the extremes in recharge, the Quincy sand and the Warden silt loam. An additional background study site upwind of the Hanford facilities has been chosen at the Yakima Firing Center. Study sites at Hanford were chosen close to micrometeorology stations on downwind transects from the operational facilities. Initial testing will be done on sites that lack perennial vegetation. Six tracer techniques (total chlortde, {sup 36}Cl, {sup 3}H, nitrate, {sup 129}I, and {sup 99}Tc) will be tested on at least one site in the Quincy sand, one site in the Warden si~ loam, and the background site, to determine which combination of tracers wortks best for a given soil type. In subsequent years, additional sites will be investigated to determine the effect of vegetation on recharge estimates and on the performance of individual tracers. The use of environmental tracers is perhaps the only cost-effective method for estimating the spatial vartability of recharge at a site as large as Hanford. The tracer techniques used at Hanford have wide applicability at other and sites operated by the U.S. Department of Energy as well as at low-level radioactive waste disposal sites.

  9. Funciones profesorales: un estudio factorial

    Directory of Open Access Journals (Sweden)

    Pedro S. de VICENTE RODRÍGUEZ

    2009-11-01

    Full Text Available La preocupación por la «cantidad» ha privado durante mucho tiempo en el ámbito educativo; ha sido considerado esencial por los gobiernos la consecución de una «educación para todos». Sin embargo, el aumento de los costos no ha conllevado una mejora sustancial, una disminución efectiva de la ineficacia de los sistemas tradicionales de enseñanza; de ello dan fe las tasas de abandonos y repeticiones de curso. Esto conduce a considerar que la falta de correspondencia entre el aumento de los recursos destinados a educación y el rendimiento de las instituciones educativas sea un problema de «calidad» más que de «cantidad». De ahí que se hable hoy insistentemente de la mejora de la calidad de la educación. Al tema de la «calidad de la educación» se dedicó en 1981 un seminario organizado por la Escuela Asturiana de estudios Hispánicos. En él, Víctor García Hoz definía la calidad educativa «como el modo de ser de la educación que reúne las características de integridad, coherencia y eficacia»1, entendiendo la eficacia como la denotación de que el fin perseguido ha sido alcanzado, más que como producción de algo material, con lo que es posible hablar en términos de eficacia refiriéndose tanto a lo cuantitativo como a lo cualitativo.

  10. The European Tracer Experiment - experimental results and database

    International Nuclear Information System (INIS)

    Nodop, K.; Connolly, R.; Girardi, F.

    1997-01-01

    As part of the European Tracer Experiment (ETEX) two successful atmospheric experiments were carried out in October and November, 1994. Perfluorocarbon (PFC) tracers were released into the atmosphere in Monterfil, Brittany, and air samples were taken at 168 stations in 17 European countries for 72 hours after the release. Upper air tracer measurements were made from three aircraft. During the first experiment a westerly air flow transported the tracer plume north-eastwards across Europe. During the second release the flow was eastwards. The results from the ground sampling network allowed the determination of the cloud evolution as far as Sweden, Poland and Bulgaria. Typical background concentrations of the tracer used are around 5 to 7 fl/l in ambient air. Concentrations in the plume ranged from 10 to above 200 fl/l. The tracer release characteristics, the tracer concentrations at the ground and in upper air, the routine and additional meteorological observations at the ground level and in upper air, trajectories derived from constant-level balloons and the meteorological input fields for long-range transport (LRT) models are assembled in the ETEX database. The ETEX database is accessible via the Internet

  11. Fluorinated tracers for imaging cancer with positron emission tomography

    International Nuclear Information System (INIS)

    Couturier, Olivier; Chatal, Jean-Francois; Luxen, Andre; Vuillez, Jean-Philippe; Rigo, Pierre; Hustinx, Roland

    2004-01-01

    2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is currently the only fluorinated tracer used in routine clinical positron emission tomography (PET). Fluorine-18 is considered the ideal radioisotope for PET imaging owing to the low positron energy (0.64 MeV), which not only limits the dose rate to the patient but also results in a relatively short range of emission in tissue, thereby providing high-resolution images. Further, the 110-min physical half-life allows for high-yield radiosynthesis, transport from the production site to the imaging site and imaging protocols that may span hours, which permits dynamic studies and assessment of potentially fairly slow metabolic processes. The synthesis of fluorinated tracers as an alternative to FDG was initially tested using nucleophilic fluorination of the molecule, as performed when radiolabelling with iodine-124 or bromide-76. However, in addition to being long, with multiple steps, this procedure is not recommended for bioactive molecules containing reactive groups such as amine or thiol groups. Radiochemical yields are also often low. More recently, radiosynthesis from prosthetic group precursors, which allows easier radiolabelling of biomolecules, has led to the development of numerous fluorinated tracers. Given the wide availability of 18 F, such tracers may well develop into important routine tracers. This article is a review of the literature concerning fluorinated radiotracers recently developed and under investigation for possible PET imaging in cancer patients. Two groups can be distinguished. The first includes ''generalist'' tracers, i.e. tracers amenable to use in a wide variety of tumours and indications, very similar in this respect to FDG. These are tracers for non-specific cell metabolism, such as protein synthesis, amino acid transport, nucleic acid synthesis or membrane component synthesis. The second group consists of ''specific'' tracers for receptor expression (i.e. oestrogens or somatostatin), cell

  12. A tracer diffusion model derived from microstructure

    International Nuclear Information System (INIS)

    Lehikoinen, Jarmo; Muurinen, Arto; Olin, Markus

    2012-01-01

    Document available in extended abstract form only. Full text of publication follows: Numerous attempts have been made to explain the tracer diffusion of various solutes in compacted clays. These attempts have commonly suffered from an inability to describe the diffusion of uncharged and charged solutes with a single unified model. Here, an internally consistent approach to describing the diffusion of solutes in a heterogeneous porous medium, such as compacted bentonite, in terms of its microstructure is presented. The microstructure is taken to be represented by a succession of unit cells, which consist of two consecutive regions (Do, 1996). In the first region, the diffusion is viewed to occur in two parallel paths: one through microcrystalline units (micropores) and the other through meso-pores between the microcrystalline units. Solutes exiting these two paths are then joined together to continue diffusing through the second, disordered, region, connecting the two adjacent microcrystalline units. Adsorption (incl. co-ion exclusion) is thought to occur in the micropores, whereas meso-pores and the disordered region accommodate free species alone. Co-ions are also assumed to experience transfer resistance into and out of the micropores, which is characterized in the model by a transmission coefficient. Although the model is not new per se, its application to compacted clays has never been attempted before. It is shown that in the limit of strong adsorption, the effective diffusivity is limited from above only by the microstructural parameters of the model porous medium. As intuitive and logical as this result may appear, it has not been proven before. In the limit of vanishing disordered region, the effective diffusivity is no longer explicitly constrained by any of the model parameters. The tortuosity of the diffusion path, i.e. the quotient of the actual diffusion path length in the porous-medium coordinates and the characteristic length of the laboratory frame

  13. Microbial DNA; a possible tracer of groundwater

    Science.gov (United States)

    Sugiyama, Ayumi; Segawa, Takuya; Furuta, Tsuyumi; Nagaosa, Kazuyo; Tsujimura, Maki; Kato, Kenji

    2017-04-01

    chemical materials dissolved in groundwater. Though viral particle was employed as a tracer to chase the movement of groundwater, it doesn't tell the chemical and physical environmental condition where the particle was incorporated into groundwater. Thus, we propose microbial DNA as a new tracer to track the route of groundwater.

  14. Evaluation of the ''Sabana de Bogota'' aquifer using isotopes techniques

    International Nuclear Information System (INIS)

    Torres, E.; Jimenez, G.; Obando, E.; Sanchez, L.; Alayon, E.

    1987-01-01

    Groundwater from the Sabana de Bogota area was studied by means of isotopic techniques such as isotope analysis, injection of tracers for determination of hydrogeological parameters, velocity measurements using tracers. These results combined with the ones obtained by conventional techniques were used to determine recharge area, origin, equipotencial lines and direction of groundwater. The results show that a combined application of classical and nuclear methods may establish rather reasonable hydrogeological concepts without investing much time and money

  15. Contamination Tracer Testing With Seabed Rock Drills: IODP Expedition 357

    Science.gov (United States)

    Orcutt, B.; Bergenthal, M.; Freudenthal, T.; Smith, D. J.; Lilley, M. D.; Schneiders, L.; Fruh-Green, G. L.

    2016-12-01

    IODP Expedition 357 utilized seabed rock drills for the first time in the history of the ocean drilling program, with the aim of collecting intact core of shallow mantle sequences from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This new drilling approach required the development of a new system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  16. Contamination tracer testing with seabed drills: IODP Expedition 357

    Science.gov (United States)

    Orcutt, Beth N.; Bergenthal, Markus; Freudenthal, Tim; Smith, David; Lilley, Marvin D.; Schnieders, Luzie; Green, Sophie; Früh-Green, Gretchen L.

    2017-11-01

    IODP Expedition 357 utilized seabed drills for the first time in the history of the ocean drilling program, with the aim of collecting intact sequences of shallow mantle core from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This novel drilling approach required the development of a new remote seafloor system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  17. Positron emitting tracers for studies of cocaine

    International Nuclear Information System (INIS)

    Fowler, J.S.; Gatley, S.J.; MacGregor, R.R.; Wolf, A.P.; Yu, D.W.; Dewey, S.L.; Schlyer, D.J.; Volkow, N.D.; Bendriem, B.; Logan, J.

    1990-01-01

    The use of PET to study the behavior and mechanism of action of therapeutic drugs and substances of abuse can be approached from a number of perspectives. The most common approach is to measure the effect of a drug on some aspect of metabolism and requires well characterized radiotracers whose behavior in vivo can be related to a discrete biochemical transformation. A second approach is to study the labeled drug itself. This provides information on the drug's regional distribution and kinetics as well as its pharmacological profile and metabolism. Cocaine has been labeled in different positions with carbon-11 and with fluorine-18 and the stereoisomers of cocaine have also been labeled to characterize its binding and metabolism in human and baboon brain. Regional cocaine binding as measured by PET is consistent with reversible binding to striatal dopamine reuptake sites and its time course parallels the behavioral activation of cocaine. The behaviorally inactive enantiomer (+)-cocaine is rapidly metabolized in serum preventing its entry into the brain. These PET tracers are useful in understanding the neurochemical basis of cocaine's action

  18. National Biomedical Tracer Facility: Project definition study

    International Nuclear Information System (INIS)

    Heaton, R.; Peterson, E.; Smith, P.

    1995-01-01

    The Los Alamos National Laboratory is an ideal institution and New Mexico is an ideal location for siting the National Biomedical Tracer Facility (NBTF). The essence of the Los Alamos proposal is the development of two complementary irradiation facilities that combined with our existing radiochemical processing hot cell facilities and waste handling and disposal facilities provide a low cost alternative to other proposals that seek to satisfy the objectives of the NBTF. We propose the construction of a 30 MeV cyclotron facility at the site of the radiochemical facilities, and the construction of a 100 MeV target station at LAMPF to satisfy the requirements and objectives of the NBTF. We do not require any modifications to our existing radiochemical processing hot cell facilities or our waste treatment and disposal facilities to accomplish the objectives of the NBTF. The total capital cost for the facility defined by the project definition study is $15.2 M. This cost estimate includes $9.9 M for the cyclotron and associated facility, $2.0 M for the 100 MeV target station at LAMPF, and $3.3 M for design

  19. Isotope and chemical tracers in groundwater hydrology

    International Nuclear Information System (INIS)

    Kendall, C.; Stewart, M.K.; Morgenstern, U.; Trompetter, V.

    1999-01-01

    The course sessions cover: session 1, Fundamentals of stable and radioactive isotopes; session 2, Stable oxygen and hydrogen isotopes in hydrology: background, examples, sampling strategy; session 3, Catchment studies using oxygen and hydrogen isotopes: background - the hydrologic water balance, evapotranspiration - the lion's share, runoff generation - new water/old water fractions, groundwater recharge - the crumbs; session 4, Isotopes in catchment hydrology: survey of applications, future developments; session 5, Applications of tritium in hydrology: background and measurement, interpretation, examples; session 6, Case studies using mixing models: Hutt Valley groundwater system, an extended mixing model for simulating tracer transport in the unsaturated zone; session 7, Groundwater dating using CFC concentrations: background, sampling and measurement, use and applications; session 8, Groundwater dating with carbon-14: background, sampling and measurement, use and applications; session 9, NZ case studies: Tauranga warm springs, North Canterbury Plains groundwater; session 10, Stable carbon and nitrogen isotopes: background and examples, biological applications of C-N-S isotopes; session 11, New developments in isotope hydrology: gas isotopes, compound specific applications, age dating of sediments etc; session 12, NZ case studies: North Canterbury Plains groundwater (continued), Waimea Plains groundwater. (author). refs., figs

  20. National Biomedical Tracer Facility: Project definition study

    Energy Technology Data Exchange (ETDEWEB)

    Heaton, R.; Peterson, E. [Los Alamos National Lab., NM (United States); Smith, P. [Smith (P.A.) Concepts and Designs (United States)

    1995-05-31

    The Los Alamos National Laboratory is an ideal institution and New Mexico is an ideal location for siting the National Biomedical Tracer Facility (NBTF). The essence of the Los Alamos proposal is the development of two complementary irradiation facilities that combined with our existing radiochemical processing hot cell facilities and waste handling and disposal facilities provide a low cost alternative to other proposals that seek to satisfy the objectives of the NBTF. We propose the construction of a 30 MeV cyclotron facility at the site of the radiochemical facilities, and the construction of a 100 MeV target station at LAMPF to satisfy the requirements and objectives of the NBTF. We do not require any modifications to our existing radiochemical processing hot cell facilities or our waste treatment and disposal facilities to accomplish the objectives of the NBTF. The total capital cost for the facility defined by the project definition study is $15.2 M. This cost estimate includes $9.9 M for the cyclotron and associated facility, $2.0 M for the 100 MeV target station at LAMPF, and $3.3 M for design.